SONUS-SONET-MIB

File: SONUS-SONET-MIB.mib (107054 bytes)

Imported modules

IF-MIB PerfHist-TC-MIB SNMPv2-SMI
SNMPv2-TC SONUS-COMMON-MIB SONUS-SMI
SONUS-TC

Imported symbols

ifIndex PerfCurrentCount PerfIntervalCount
Integer32 MODULE-IDENTITY NOTIFICATION-TYPE
OBJECT-TYPE DisplayString RowStatus
TruthValue sonusEventClass sonusEventDescription
sonusEventLevel sonusPortIndex sonusShelfIndex
sonusSlotIndex sonusCircuitMIBs SonusAdminAction
SonusAdminState SonusName SonusServiceState
SonusShelfIndex SonusSlotIndex

Defined Types

SonusSonetPortAdmnEntry  
SEQUENCE    
  sonusSonetPortAdmnIfIndex Integer32
  sonusSonetPortAdmnShelfIndex SonusShelfIndex
  sonusSonetPortAdmnSlotIndex SonusSlotIndex
  sonusSonetPortAdmnPortIndex Integer32
  sonusSonetPortAdmnRowStatus RowStatus
  sonusSonetPortAdmnName SonusName
  sonusSonetPortAdmnState SonusAdminState
  sonusSonetPortAdmnMode SonusServiceState
  sonusSonetPortAdmnAction SonusAdminAction
  sonusSonetPortAdmnTimeout Integer32
  sonusSonetPortAdmnStatAction INTEGER
  sonusSonetPortAdmnLaserState INTEGER
  sonusSonetPortAdmn24hTimeElapsed Integer32
  sonusSonetPortAdmnOperStatus INTEGER
  sonusSonetPortAdmnDs3ModeOverride SonusAdminState
  sonusSonetPortAdmnStsXmtScramble SonusAdminState
  sonusSonetPortAdmnStsRcvDescramble SonusAdminState
  sonusSonetPortAdmnAtmXmtScramble SonusAdminState
  sonusSonetPortAdmnAtmRcvDescramble SonusAdminState

SonusSonetSectionThresholdEntry  
SEQUENCE    
  sonusSonetSectionThresholdIfIndex Integer32
  sonusSonetSectionThreshold15mCVs Integer32
  sonusSonetSectionThreshold15mESs Integer32
  sonusSonetSectionThreshold15mSESs Integer32
  sonusSonetSectionThreshold15mSEFSs Integer32
  sonusSonetSectionThreshold24hCVs Integer32
  sonusSonetSectionThreshold24hESs Integer32
  sonusSonetSectionThreshold24hSESs Integer32
  sonusSonetSectionThreshold24hSEFSs Integer32

SonusSonetSectionCurrentEntry  
SEQUENCE    
  sonusSonetSectionCurrentIfIndex Integer32
  sonusSonetSectionCurrentStatus Integer32
  sonusSonetSectionCurrentESs PerfCurrentCount
  sonusSonetSectionCurrentSESs PerfCurrentCount
  sonusSonetSectionCurrentSEFSs PerfCurrentCount
  sonusSonetSectionCurrentCVs PerfCurrentCount

SonusSonetSectionIntervalEntry  
SEQUENCE    
  sonusSonetSectionIntervalIfIndex Integer32
  sonusSonetSectionIntervalNumber Integer32
  sonusSonetSectionIntervalESs PerfCurrentCount
  sonusSonetSectionIntervalSESs PerfCurrentCount
  sonusSonetSectionIntervalSEFSs PerfCurrentCount
  sonusSonetSectionIntervalCVs PerfCurrentCount
  sonusSonetSectionIntervalValidData TruthValue

SonusSonetLineThresholdEntry  
SEQUENCE    
  sonusSonetLineThresholdIfIndex Integer32
  sonusSonetLineThreshold15mCVs Integer32
  sonusSonetLineThreshold15mESs Integer32
  sonusSonetLineThreshold15mSESs Integer32
  sonusSonetLineThreshold15mUASs Integer32
  sonusSonetLineThreshold24hCVs Integer32
  sonusSonetLineThreshold24hESs Integer32
  sonusSonetLineThreshold24hSESs Integer32
  sonusSonetLineThreshold24hUASs Integer32

SonusSonetLineCurrentEntry  
SEQUENCE    
  sonusSonetLineCurrentIfIndex Integer32
  sonusSonetLineCurrentStatus Integer32
  sonusSonetLineCurrentESs PerfCurrentCount
  sonusSonetLineCurrentSESs PerfCurrentCount
  sonusSonetLineCurrentUASs PerfCurrentCount
  sonusSonetLineCurrentCVs PerfCurrentCount
  sonusSonetLineCurrentFCs PerfCurrentCount

SonusSonetLineIntervalEntry  
SEQUENCE    
  sonusSonetLineIntervalIfIndex Integer32
  sonusSonetLineIntervalNumber Integer32
  sonusSonetLineIntervalESs PerfIntervalCount
  sonusSonetLineIntervalSESs PerfIntervalCount
  sonusSonetLineIntervalUASs PerfIntervalCount
  sonusSonetLineIntervalCVs PerfIntervalCount
  sonusSonetLineIntervalFCs PerfIntervalCount
  sonusSonetLineIntervalValidData TruthValue

SonusSonetFarEndLineCurrentEntry  
SEQUENCE    
  sonusSonetFarEndLineCurrentIfIndex Integer32
  sonusSonetFarEndLineCurrentESs PerfCurrentCount
  sonusSonetFarEndLineCurrentSESs PerfCurrentCount
  sonusSonetFarEndLineCurrentUASs PerfCurrentCount
  sonusSonetFarEndLineCurrentCVs PerfCurrentCount
  sonusSonetFarEndLineCurrentFCs PerfCurrentCount

SonusSonetFarEndLineIntervalEntry  
SEQUENCE    
  sonusSonetFarEndLineIntervalIfIndex Integer32
  sonusSonetFarEndLineIntervalNumber Integer32
  sonusSonetFarEndLineIntervalESs PerfIntervalCount
  sonusSonetFarEndLineIntervalSESs PerfIntervalCount
  sonusSonetFarEndLineIntervalUASs PerfIntervalCount
  sonusSonetFarEndLineIntervalCVs PerfIntervalCount
  sonusSonetFarEndLineIntervalFCs PerfIntervalCount
  sonusSonetFarEndLineIntervalValidData TruthValue

SonusSonetLineFailureCurrentEntry  
SEQUENCE    
  sonusSonetLineFailureCurrentIfIndex Integer32
  sonusSonetLineFailureCurrentFCs PerfCurrentCount

SonusSonetLineFailureIntervalEntry  
SEQUENCE    
  sonusSonetLineFailureIntervalIfIndex Integer32
  sonusSonetLineFailureIntervalNumber Integer32
  sonusSonetLineFailureIntervalFCs PerfCurrentCount

SonusSonetFarEndLineFailureCurrentEntry  
SEQUENCE    
  sonusSonetFarEndLineFailureCurrentIfIndex Integer32
  sonusSonetFarEndLineFailureCurrentFCs PerfCurrentCount

SonusSonetFarEndLineFailureIntervalEntry  
SEQUENCE    
  sonusSonetFarEndLineFailureIntervalIfIndex Integer32
  sonusSonetFarEndLineFailureIntervalNumber Integer32
  sonusSonetFarEndLineFailureIntervalFCs PerfCurrentCount

SonusSonetLayerEntry  
SEQUENCE    
  sonusSonetLayerShelfIndex SonusShelfIndex
  sonusSonetLayerSlotIndex SonusSlotIndex
  sonusSonetLayerPortIndex Integer32
  sonusSonetLayerIfIndex Integer32
  sonusSonetLayerRowStatus RowStatus

SonusSonetPathAdmnEntry  
SEQUENCE    
  sonusSonetPathAdmnIfIndex Integer32
  sonusSonetPathAdmnShelfIndex SonusShelfIndex
  sonusSonetPathAdmnSlotIndex SonusSlotIndex
  sonusSonetPathAdmnPortIndex Integer32
  sonusSonetPathAdmnPathIndex Integer32
  sonusSonetPathAdmnRowStatus RowStatus
  sonusSonetPathAdmnState SonusAdminState
  sonusSonetPathAdmnMode SonusServiceState
  sonusSonetPathAdmnAction SonusAdminAction
  sonusSonetPathAdmnTimeout Integer32
  sonusSonetPathAdmnStatAction INTEGER
  sonusSonetPathAdmnRDIMode INTEGER
  sonusSonetPathAdmnTraceState SonusAdminState
  sonusSonetPathAdmnTraceExpMsg DisplayString
  sonusSonetPathAdmnTraceXmtMsg DisplayString
  sonusSonetPathAdmnTraceRcvMsg DisplayString
  sonusSonetPathAdmnOperStatus INTEGER
  sonusSonetPathAdmnDs3ModeOverride SonusAdminState

SonusSonetPathThresholdEntry  
SEQUENCE    
  sonusSonetPathThresholdIfIndex Integer32
  sonusSonetPathThresholdPathIndex Integer32
  sonusSonetPathThreshold15mCVs Integer32
  sonusSonetPathThreshold15mESs Integer32
  sonusSonetPathThreshold15mSESs Integer32
  sonusSonetPathThreshold15mUASs Integer32
  sonusSonetPathThreshold24hCVs Integer32
  sonusSonetPathThreshold24hESs Integer32
  sonusSonetPathThreshold24hSESs Integer32
  sonusSonetPathThreshold24hUASs Integer32

SonusSonetPathCurrentEntry  
SEQUENCE    
  sonusSonetPathCurrentIfIndex Integer32
  sonusSonetPathCurrentPathIndex Integer32
  sonusSonetPathCurrentWidth INTEGER
  sonusSonetPathCurrentStatus Integer32
  sonusSonetPathCurrentESs PerfCurrentCount
  sonusSonetPathCurrentSESs PerfCurrentCount
  sonusSonetPathCurrentUASs PerfCurrentCount
  sonusSonetPathCurrentCVs PerfCurrentCount
  sonusSonetPathCurrentFCs PerfCurrentCount
  sonusSonetPathCurrentTraceStatus INTEGER

SonusSonetPathIntervalEntry  
SEQUENCE    
  sonusSonetPathIntervalIfIndex Integer32
  sonusSonetPathIntervalPathIndex Integer32
  sonusSonetPathIntervalNumber Integer32
  sonusSonetPathIntervalESs PerfIntervalCount
  sonusSonetPathIntervalSESs PerfIntervalCount
  sonusSonetPathIntervalUASs PerfIntervalCount
  sonusSonetPathIntervalCVs PerfIntervalCount
  sonusSonetPathIntervalFCs PerfIntervalCount
  sonusSonetPathIntervalValidData TruthValue

SonusSonetFarEndPathCurrentEntry  
SEQUENCE    
  sonusSonetFarEndPathCurrentIfIndex Integer32
  sonusSonetFarEndPathCurrentPathIndex Integer32
  sonusSonetFarEndPathCurrentESs PerfCurrentCount
  sonusSonetFarEndPathCurrentSESs PerfCurrentCount
  sonusSonetFarEndPathCurrentUASs PerfCurrentCount
  sonusSonetFarEndPathCurrentCVs PerfCurrentCount
  sonusSonetFarEndPathCurrentFCs PerfCurrentCount

SonusSonetFarEndPathIntervalEntry  
SEQUENCE    
  sonusSonetFarEndPathIntervalIfIndex Integer32
  sonusSonetFarEndPathIntervalPathIndex Integer32
  sonusSonetFarEndPathIntervalNumber Integer32
  sonusSonetFarEndPathIntervalESs PerfIntervalCount
  sonusSonetFarEndPathIntervalSESs PerfIntervalCount
  sonusSonetFarEndPathIntervalUASs PerfIntervalCount
  sonusSonetFarEndPathIntervalCVs PerfIntervalCount
  sonusSonetFarEndPathIntervalFCs PerfIntervalCount
  sonusSonetFarEndPathIntervalValidData TruthValue

SonusSonetPathFailureCurrentEntry  
SEQUENCE    
  sonusSonetPathFailureCurrentIfIndex Integer32
  sonusSonetPathFailureCurrentPathIndex Integer32
  sonusSonetPathFailureCurrentFCs PerfCurrentCount
  sonusSonetPathFailureCurrentTraceStatus INTEGER

SonusSonetPathFailureIntervalEntry  
SEQUENCE    
  sonusSonetPathFailureIntervalIfIndex Integer32
  sonusSonetPathFailureIntervalPathIndex Integer32
  sonusSonetPathFailureIntervalNumber Integer32
  sonusSonetPathFailureIntervalFCs PerfCurrentCount

SonusSonetFarEndPathFailureCurrentEntry  
SEQUENCE    
  sonusSonetFarEndPathFailureCurrentIfIndex Integer32
  sonusSonetFarEndPathFailureCurrentPathIndex Integer32
  sonusSonetFarEndPathFailureCurrentFCs PerfCurrentCount

SonusSonetFarEndPathFailureIntervalEntry  
SEQUENCE    
  sonusSonetFarEndPathFailureIntervalIfIndex Integer32
  sonusSonetFarEndPathFailureIntervalPathIndex Integer32
  sonusSonetFarEndPathFailureIntervalNumber Integer32
  sonusSonetFarEndPathFailureIntervalFCs PerfCurrentCount

Defined Values

sonusSonetMIB 1.3.6.1.4.1.2879.2.4.3
The MIB Module for Sonus SONET/SDH extensions.
MODULE-IDENTITY    

sonusSonetObjects 1.3.6.1.4.1.2879.2.4.3.1
OBJECT IDENTIFIER    

sonusSonetPortAdmn 1.3.6.1.4.1.2879.2.4.3.1.1
OBJECT IDENTIFIER    

sonusSonetPortAdmnTable 1.3.6.1.4.1.2879.2.4.3.1.1.1
The Sonus SONET Port Admn Table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SonusSonetPortAdmnEntry

sonusSonetPortAdmnEntry 1.3.6.1.4.1.2879.2.4.3.1.1.1.1
An entry in the Sonus SONET Port Admn table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SonusSonetPortAdmnEntry  

sonusSonetPortAdmnIfIndex 1.3.6.1.4.1.2879.2.4.3.1.1.1.1.1
The ifIndex assigned to this port when it was created. This will not change until the port is deleted.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

sonusSonetPortAdmnShelfIndex 1.3.6.1.4.1.2879.2.4.3.1.1.1.1.2
Shelf index for this table.
Status: current Access: read-write
OBJECT-TYPE    
  SonusShelfIndex  

sonusSonetPortAdmnSlotIndex 1.3.6.1.4.1.2879.2.4.3.1.1.1.1.3
Slot index for this table.
Status: current Access: read-write
OBJECT-TYPE    
  SonusSlotIndex  

sonusSonetPortAdmnPortIndex 1.3.6.1.4.1.2879.2.4.3.1.1.1.1.4
OC3 port index for this table.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..4  

sonusSonetPortAdmnRowStatus 1.3.6.1.4.1.2879.2.4.3.1.1.1.1.5
This object is used to create, delete, or modify a row in this table.
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

sonusSonetPortAdmnName 1.3.6.1.4.1.2879.2.4.3.1.1.1.1.6
Name of this STS3
Status: current Access: read-write
OBJECT-TYPE    
  SonusName  

sonusSonetPortAdmnState 1.3.6.1.4.1.2879.2.4.3.1.1.1.1.7
State of STS3, Enabled/Disabled
Status: current Access: read-write
OBJECT-TYPE    
  SonusAdminState  

sonusSonetPortAdmnMode 1.3.6.1.4.1.2879.2.4.3.1.1.1.1.8
SONET port entries are created with a mode of outOfService. A SONET port which is outOfService has had all active calls terminated. A SOENT port must be outOfService in order to change its state to disabled.
Status: current Access: read-write
OBJECT-TYPE    
  SonusServiceState  

sonusSonetPortAdmnAction 1.3.6.1.4.1.2879.2.4.3.1.1.1.1.9
The type of action to perform when a SONET port is taken out of service. The SONET port can be dried up, or it can be forced out of service.
Status: current Access: read-write
OBJECT-TYPE    
  SonusAdminAction  

sonusSonetPortAdmnTimeout 1.3.6.1.4.1.2879.2.4.3.1.1.1.1.10
The Dryup Timeout specifies the maximum amount of time to wait for all active calls to terminate on a SONET port before the port should be taken out-of-service.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..1440  

sonusSonetPortAdmnStatAction 1.3.6.1.4.1.2879.2.4.3.1.1.1.1.11
Initialize Performance Monitoring Statistics. A PM initialization action initiates one request for the action. Requests to initialize more than one group of statistics can be accomplished by OR-ing the appropriate bits (e.g., to initialize all 15 minute PM statistics, set bits 1 and 2). Reading this variable always returns zero.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER init15MinuteNearEnd(1), init15MinuteFarEnd(2), init24HourNearEnd(4), init24HourFarEnd(8)  

sonusSonetPortAdmnLaserState 1.3.6.1.4.1.2879.2.4.3.1.1.1.1.12
Controls whether the fiber-optic laser is On or Off.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2)  

sonusSonetPortAdmn24hTimeElapsed 1.3.6.1.4.1.2879.2.4.3.1.1.1.1.13
The number of seconds, including partial seconds, that have elapsed since the beginning of the current 24 hour measurement period.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..86400  

sonusSonetPortAdmnOperStatus 1.3.6.1.4.1.2879.2.4.3.1.1.1.1.14
The actual status of the Sonet interface. Interface is Up if it is administratively in service and there are no line failures or hardware failures. Interface is Down if it is administratively in service and there are line failures or hardware failures, or if it is administratively out of service. Interface is DryingUp if it is administratively out of service and is drying up (no new calls, still carrying in-progress calls). OTHER VALUES ARE NO LONGER SUPPORTED
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enabledInService(1), enabledOutOfService(2), enabledDown(3), dryingUp(4), disabled(5), up(6), down(7)  

sonusSonetPortAdmnDs3ModeOverride 1.3.6.1.4.1.2879.2.4.3.1.1.1.1.15
This flag controls whether the mode and state of the Paths carried in an OC3 are modified when the mode and state of the OC3 is modified. If this flag is set to Enabled, the Path state and mode are not changed when the OC3 mode and state are changed.
Status: current Access: read-write
OBJECT-TYPE    
  SonusAdminState  

sonusSonetPortAdmnStsXmtScramble 1.3.6.1.4.1.2879.2.4.3.1.1.1.1.16
Controls whether the transmitted STS-N data stream is scrambled. If this flag is set to Enabled, the data is scrambled.
Status: current Access: read-write
OBJECT-TYPE    
  SonusAdminState  

sonusSonetPortAdmnStsRcvDescramble 1.3.6.1.4.1.2879.2.4.3.1.1.1.1.17
Controls whether the received STS-N data stream is descrambled. If this flag is set to Enabled, the data is descrambled.
Status: current Access: read-write
OBJECT-TYPE    
  SonusAdminState  

sonusSonetPortAdmnAtmXmtScramble 1.3.6.1.4.1.2879.2.4.3.1.1.1.1.18
Controls whether the transmitted ATM payload data is scrambled. If this flag is set to Enabled, the data is scrambled. This object only pertains to interfaces carrying ATM.
Status: current Access: read-write
OBJECT-TYPE    
  SonusAdminState  

sonusSonetPortAdmnAtmRcvDescramble 1.3.6.1.4.1.2879.2.4.3.1.1.1.1.19
Controls whether the received ATM payload data is descrambled. If this flag is set to Enabled, the data is descrambled. This object only pertains to interfaces carrying ATM.
Status: current Access: read-write
OBJECT-TYPE    
  SonusAdminState  

sonusSonetSection 1.3.6.1.4.1.2879.2.4.3.1.2
OBJECT IDENTIFIER    

sonusSonetSectionThresholdTable 1.3.6.1.4.1.2879.2.4.3.1.2.1
The Sonus SONET Section Threshold Table. This table adds objects to set the Performance Monitoring thresholds for generating a Threshold Crossing Alert.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SonusSonetSectionThresholdEntry

sonusSonetSectionThresholdEntry 1.3.6.1.4.1.2879.2.4.3.1.2.1.1
An entry in the Sonus SONET Section Threshold table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SonusSonetSectionThresholdEntry  

sonusSonetSectionThresholdIfIndex 1.3.6.1.4.1.2879.2.4.3.1.2.1.1.1
The ifIndex assigned to this port when it was created. This will not change until the port is deleted.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

sonusSonetSectionThreshold15mCVs 1.3.6.1.4.1.2879.2.4.3.1.2.1.1.2
Threshold for 15 minute interval Section layer Coding Violations.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..16383  

sonusSonetSectionThreshold15mESs 1.3.6.1.4.1.2879.2.4.3.1.2.1.1.3
Threshold for 15 minute interval Section layer Errored Seconds.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..16383  

sonusSonetSectionThreshold15mSESs 1.3.6.1.4.1.2879.2.4.3.1.2.1.1.4
Threshold for 15 minute interval Section layer Severely Errored Seconds.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..900  

sonusSonetSectionThreshold15mSEFSs 1.3.6.1.4.1.2879.2.4.3.1.2.1.1.5
Threshold for 15 minute interval Section layer Severely Errored Frame Seconds.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..900  

sonusSonetSectionThreshold24hCVs 1.3.6.1.4.1.2879.2.4.3.1.2.1.1.6
Threshold for 24 hour interval Section layer Coding Violations.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..1048575  

sonusSonetSectionThreshold24hESs 1.3.6.1.4.1.2879.2.4.3.1.2.1.1.7
Threshold for 24 hour interval Section layer Errored Seconds.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..65535  

sonusSonetSectionThreshold24hSESs 1.3.6.1.4.1.2879.2.4.3.1.2.1.1.8
Threshold for 24 hour interval Section layer Severely Errored Seconds.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..65535  

sonusSonetSectionThreshold24hSEFSs 1.3.6.1.4.1.2879.2.4.3.1.2.1.1.9
Threshold for 24 hour interval Section layer Severely Errored Frame Seconds.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..65535  

sonusSonetSectionCurrentTable 1.3.6.1.4.1.2879.2.4.3.1.2.2
The Sonus SONET Section Current table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SonusSonetSectionCurrentEntry

sonusSonetSectionCurrentEntry 1.3.6.1.4.1.2879.2.4.3.1.2.2.1
An entry in the Sonus SONET Section Current table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SonusSonetSectionCurrentEntry  

sonusSonetSectionCurrentIfIndex 1.3.6.1.4.1.2879.2.4.3.1.2.2.1.1
The ifIndex assigned to this port when it was created. This will not change until the port is deleted.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

sonusSonetSectionCurrentStatus 1.3.6.1.4.1.2879.2.4.3.1.2.2.1.2
This variable indicates the status of the interface. It is a bit map represented as a sum, therefore, it can represent multiple defects simultaneously. The sonetSectionNoDefect should be set if and only if no other flag is set. The various bit positions are: 1 sonetSectionNoDefect 2 sonetSectionLOS 4 sonetSectionLOF
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..6  

sonusSonetSectionCurrentESs 1.3.6.1.4.1.2879.2.4.3.1.2.2.1.3
The counter associated with the number of Errored Seconds encountered by a SONET/SDH Section in the current 24 hour interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfCurrentCount  

sonusSonetSectionCurrentSESs 1.3.6.1.4.1.2879.2.4.3.1.2.2.1.4
The counter associated with the number of Severely Errored Seconds encountered by a SONET/SDH Section in the current 24 hour interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfCurrentCount  

sonusSonetSectionCurrentSEFSs 1.3.6.1.4.1.2879.2.4.3.1.2.2.1.5
The counter associated with the number of Severely Errored Framing Seconds encountered by a SONET/SDH Section in the current 24 hour interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfCurrentCount  

sonusSonetSectionCurrentCVs 1.3.6.1.4.1.2879.2.4.3.1.2.2.1.6
The counter associated with the number of Coding Violations encountered by a SONET/SDH Section in the current 24 hour interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfCurrentCount  

sonusSonetSectionIntervalTable 1.3.6.1.4.1.2879.2.4.3.1.2.3
The Sonus SONET Section Interval table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SonusSonetSectionIntervalEntry

sonusSonetSectionIntervalEntry 1.3.6.1.4.1.2879.2.4.3.1.2.3.1
An entry in the Sonus SONET Section Interval table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SonusSonetSectionIntervalEntry  

sonusSonetSectionIntervalIfIndex 1.3.6.1.4.1.2879.2.4.3.1.2.3.1.1
The ifIndex assigned to this port when it was created. This will not change until the port is deleted.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

sonusSonetSectionIntervalNumber 1.3.6.1.4.1.2879.2.4.3.1.2.3.1.2
The number 1 identifies the most recently completed 24 hour interval. In the future if more 24 hour intervals are supported, the interval identified by N is the interval immediately preceding the one identified by N-1.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1  

sonusSonetSectionIntervalESs 1.3.6.1.4.1.2879.2.4.3.1.2.3.1.3
The counter associated with the number of Errored Seconds encountered by a SONET/SDH Section in the previous 24 hour interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfCurrentCount  

sonusSonetSectionIntervalSESs 1.3.6.1.4.1.2879.2.4.3.1.2.3.1.4
The counter associated with the number of Severely Errored Seconds encountered by a SONET/SDH Section in the previous 24 hour interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfCurrentCount  

sonusSonetSectionIntervalSEFSs 1.3.6.1.4.1.2879.2.4.3.1.2.3.1.5
The counter associated with the number of Severely Errored Framing Seconds encountered by a SONET/SDH Section in the previous 24 hour interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfCurrentCount  

sonusSonetSectionIntervalCVs 1.3.6.1.4.1.2879.2.4.3.1.2.3.1.6
The counter associated with the number of Coding Violations encountered by a SONET/SDH Section in the previous 24 hour interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfCurrentCount  

sonusSonetSectionIntervalValidData 1.3.6.1.4.1.2879.2.4.3.1.2.3.1.7
This variable indicates if the data for this interval is valid.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

sonusSonetLine 1.3.6.1.4.1.2879.2.4.3.1.3
OBJECT IDENTIFIER    

sonusSonetLineThresholdTable 1.3.6.1.4.1.2879.2.4.3.1.3.1
The Sonus SONET Line Threshold Table. This table adds objects to set the Performance Monitoring thresholds for generating a Threshold Crossing Alert.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SonusSonetLineThresholdEntry

sonusSonetLineThresholdEntry 1.3.6.1.4.1.2879.2.4.3.1.3.1.1
An entry in the Sonus SONET Line Threshold table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SonusSonetLineThresholdEntry  

sonusSonetLineThresholdIfIndex 1.3.6.1.4.1.2879.2.4.3.1.3.1.1.1
The ifIndex assigned to this port when it was created. This will not change until the port is deleted.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

sonusSonetLineThreshold15mCVs 1.3.6.1.4.1.2879.2.4.3.1.3.1.1.2
Threshold for 15 minute interval Line layer Coding Violations.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..16383  

sonusSonetLineThreshold15mESs 1.3.6.1.4.1.2879.2.4.3.1.3.1.1.3
Threshold for 15 minute interval Line layer Errored Seconds.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..900  

sonusSonetLineThreshold15mSESs 1.3.6.1.4.1.2879.2.4.3.1.3.1.1.4
Threshold for 15 minute interval Line layer Severely Errored Seconds.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..900  

sonusSonetLineThreshold15mUASs 1.3.6.1.4.1.2879.2.4.3.1.3.1.1.5
Threshold for 15 minute interval Line layer Unavailable Seconds.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..900  

sonusSonetLineThreshold24hCVs 1.3.6.1.4.1.2879.2.4.3.1.3.1.1.6
Threshold for 24 hour interval Line layer Coding Violations.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..1048575  

sonusSonetLineThreshold24hESs 1.3.6.1.4.1.2879.2.4.3.1.3.1.1.7
Threshold for 24 hour interval Line layer Errored Seconds.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..65535  

sonusSonetLineThreshold24hSESs 1.3.6.1.4.1.2879.2.4.3.1.3.1.1.8
Threshold for 24 hour interval Line layer Severely Errored Seconds.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..65535  

sonusSonetLineThreshold24hUASs 1.3.6.1.4.1.2879.2.4.3.1.3.1.1.9
Threshold for 24 hour interval Line layer Unavailable Seconds.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..65535  

sonusSonetLineCurrentTable 1.3.6.1.4.1.2879.2.4.3.1.3.2
The Sonus SONET Line Current table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SonusSonetLineCurrentEntry

sonusSonetLineCurrentEntry 1.3.6.1.4.1.2879.2.4.3.1.3.2.1
An entry in the Sonus SONET Line Current table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SonusSonetLineCurrentEntry  

sonusSonetLineCurrentIfIndex 1.3.6.1.4.1.2879.2.4.3.1.3.2.1.1
The ifIndex assigned to this port when it was created. This will not change until the port is deleted.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

sonusSonetLineCurrentStatus 1.3.6.1.4.1.2879.2.4.3.1.3.2.1.2
This variable indicates the status of the interface. It is a bit map represented as a sum, therefore, it can represent multiple defects simultaneously. The sonetLineNoDefect should be set if and only if no other flag is set. The various bit positions are: 1 sonetSectionNoDefect 2 sonetLineAIS 4 sonetLineRDI
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..6  

sonusSonetLineCurrentESs 1.3.6.1.4.1.2879.2.4.3.1.3.2.1.3
The counter associated with the number of Errored Seconds encountered by a SONET/SDH Line in the current 24 hour interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfCurrentCount  

sonusSonetLineCurrentSESs 1.3.6.1.4.1.2879.2.4.3.1.3.2.1.4
The counter associated with the number of Severely Errored Seconds encountered by a SONET/SDH Line in the current 24 hour interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfCurrentCount  

sonusSonetLineCurrentUASs 1.3.6.1.4.1.2879.2.4.3.1.3.2.1.5
The counter associated with the number of Unavailable Seconds encountered by a SONET/SDH Line in the current 24 hour interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfCurrentCount  

sonusSonetLineCurrentCVs 1.3.6.1.4.1.2879.2.4.3.1.3.2.1.6
The counter associated with the number of Coding Violations encountered by a SONET/SDH Line in the current 24 hour interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfCurrentCount  

sonusSonetLineCurrentFCs 1.3.6.1.4.1.2879.2.4.3.1.3.2.1.7
The counter associated with the number of Failures encountered by a SONET/SDH Line in the current 24 hour interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfCurrentCount  

sonusSonetLineIntervalTable 1.3.6.1.4.1.2879.2.4.3.1.3.3
The Sonus SONET Line Interval table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SonusSonetLineIntervalEntry

sonusSonetLineIntervalEntry 1.3.6.1.4.1.2879.2.4.3.1.3.3.1
An entry in the Sonus SONET Line Interval table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SonusSonetLineIntervalEntry  

sonusSonetLineIntervalIfIndex 1.3.6.1.4.1.2879.2.4.3.1.3.3.1.1
The ifIndex assigned to this port when it was created. This will not change until the port is deleted.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

sonusSonetLineIntervalNumber 1.3.6.1.4.1.2879.2.4.3.1.3.3.1.2
The number 1 identifies the most recently completed 24 hour interval. In the future if more 24 hour intervals are supported, the interval identified by N is the interval immediately preceding the one identified by N-1.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1  

sonusSonetLineIntervalESs 1.3.6.1.4.1.2879.2.4.3.1.3.3.1.3
The counter associated with the number of Errored Seconds encountered by a SONET/SDH Line in the previous 24 hour interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfIntervalCount  

sonusSonetLineIntervalSESs 1.3.6.1.4.1.2879.2.4.3.1.3.3.1.4
The counter associated with the number of Severely Errored Seconds encountered by a SONET/SDH Line in the previous 24 hour interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfIntervalCount  

sonusSonetLineIntervalUASs 1.3.6.1.4.1.2879.2.4.3.1.3.3.1.5
The counter associated with the number of Unavailable Seconds encountered by a SONET/SDH Line in the previous 24 hour interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfIntervalCount  

sonusSonetLineIntervalCVs 1.3.6.1.4.1.2879.2.4.3.1.3.3.1.6
The counter associated with the number of Coding Violations encountered by a SONET/SDH Line in the previous 24 hour interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfIntervalCount  

sonusSonetLineIntervalFCs 1.3.6.1.4.1.2879.2.4.3.1.3.3.1.7
The counter associated with the number of Failures encountered by a SONET/SDH Line in the previous 24 hour interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfIntervalCount  

sonusSonetLineIntervalValidData 1.3.6.1.4.1.2879.2.4.3.1.3.3.1.8
This variable indicates if the data for this interval is valid.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

sonusSonetFarEndLineCurrentTable 1.3.6.1.4.1.2879.2.4.3.1.3.4
The Sonus SONET Far End Line Current table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SonusSonetFarEndLineCurrentEntry

sonusSonetFarEndLineCurrentEntry 1.3.6.1.4.1.2879.2.4.3.1.3.4.1
An entry in the Sonus SONET Far End Line Current table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SonusSonetFarEndLineCurrentEntry  

sonusSonetFarEndLineCurrentIfIndex 1.3.6.1.4.1.2879.2.4.3.1.3.4.1.1
The ifIndex assigned to this port when it was created. This will not change until the port is deleted.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

sonusSonetFarEndLineCurrentESs 1.3.6.1.4.1.2879.2.4.3.1.3.4.1.2
The counter associated with the number of Far End Errored Seconds encountered by a SONET/SDH Line in the current 24 hour interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfCurrentCount  

sonusSonetFarEndLineCurrentSESs 1.3.6.1.4.1.2879.2.4.3.1.3.4.1.3
The counter associated with the number of Far End Severely Errored Seconds encountered by a SONET/SDH Line in the current 24 hour interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfCurrentCount  

sonusSonetFarEndLineCurrentUASs 1.3.6.1.4.1.2879.2.4.3.1.3.4.1.4
The counter associated with the number of Far End Unavailable Seconds encountered by a SONET/SDH Line in the current 24 hour interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfCurrentCount  

sonusSonetFarEndLineCurrentCVs 1.3.6.1.4.1.2879.2.4.3.1.3.4.1.5
The counter associated with the number of Far End Coding Violations encountered by a SONET/SDH Line in the current 24 hour interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfCurrentCount  

sonusSonetFarEndLineCurrentFCs 1.3.6.1.4.1.2879.2.4.3.1.3.4.1.6
The counter associated with the number of Far End Failures encountered by a SONET/SDH Line in the current 24 hour interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfCurrentCount  

sonusSonetFarEndLineIntervalTable 1.3.6.1.4.1.2879.2.4.3.1.3.5
The Sonus SONET Far End Line Interval table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SonusSonetFarEndLineIntervalEntry

sonusSonetFarEndLineIntervalEntry 1.3.6.1.4.1.2879.2.4.3.1.3.5.1
An entry in the Sonus SONET Far End Line Interval table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SonusSonetFarEndLineIntervalEntry  

sonusSonetFarEndLineIntervalIfIndex 1.3.6.1.4.1.2879.2.4.3.1.3.5.1.1
The ifIndex assigned to this port when it was created. This will not change until the port is deleted.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

sonusSonetFarEndLineIntervalNumber 1.3.6.1.4.1.2879.2.4.3.1.3.5.1.2
The number 1 identifies the most recently completed 24 hour interval. In the future if more 24 hour intervals are supported, the interval identified by N is the interval immediately preceding the one identified by N-1.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1  

sonusSonetFarEndLineIntervalESs 1.3.6.1.4.1.2879.2.4.3.1.3.5.1.3
The counter associated with the number of Far End Errored Seconds encountered by a SONET/SDH Line in the current 24 hour interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfIntervalCount  

sonusSonetFarEndLineIntervalSESs 1.3.6.1.4.1.2879.2.4.3.1.3.5.1.4
The counter associated with the number of Far End Severely Errored Seconds encountered by a SONET/SDH Line in the current 24 hour interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfIntervalCount  

sonusSonetFarEndLineIntervalUASs 1.3.6.1.4.1.2879.2.4.3.1.3.5.1.5
The counter associated with the number of Far End Unavailable Seconds encountered by a SONET/SDH Line in the current 24 hour interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfIntervalCount  

sonusSonetFarEndLineIntervalCVs 1.3.6.1.4.1.2879.2.4.3.1.3.5.1.6
The counter associated with the number of Far End Coding Violations encountered by a SONET/SDH Line in the current 24 hour interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfIntervalCount  

sonusSonetFarEndLineIntervalFCs 1.3.6.1.4.1.2879.2.4.3.1.3.5.1.7
The counter associated with the number of Far End Failures encountered by a SONET/SDH Line in the current 24 hour interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfIntervalCount  

sonusSonetFarEndLineIntervalValidData 1.3.6.1.4.1.2879.2.4.3.1.3.5.1.8
This variable indicates if the data for this interval is valid.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

sonusSonetLineFailureCurrentTable 1.3.6.1.4.1.2879.2.4.3.1.3.6
The Sonus SONET Line Failure Current table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SonusSonetLineFailureCurrentEntry

sonusSonetLineFailureCurrentEntry 1.3.6.1.4.1.2879.2.4.3.1.3.6.1
An entry in the Sonus SONET Line Failure Current table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SonusSonetLineFailureCurrentEntry  

sonusSonetLineFailureCurrentIfIndex 1.3.6.1.4.1.2879.2.4.3.1.3.6.1.1
The ifIndex assigned to this port when it was created. This will not change until the port is deleted.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

sonusSonetLineFailureCurrentFCs 1.3.6.1.4.1.2879.2.4.3.1.3.6.1.2
The counter associated with the number of Failures encountered by a SONET/SDH Line in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfCurrentCount  

sonusSonetLineFailureIntervalTable 1.3.6.1.4.1.2879.2.4.3.1.3.7
The Sonus SONET Line Failure Interval table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SonusSonetLineFailureIntervalEntry

sonusSonetLineFailureIntervalEntry 1.3.6.1.4.1.2879.2.4.3.1.3.7.1
An entry in the Sonus SONET Line Failure Interval table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SonusSonetLineFailureIntervalEntry  

sonusSonetLineFailureIntervalIfIndex 1.3.6.1.4.1.2879.2.4.3.1.3.7.1.1
The ifIndex assigned to this port when it was created. This will not change until the port is deleted.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

sonusSonetLineFailureIntervalNumber 1.3.6.1.4.1.2879.2.4.3.1.3.7.1.2
A number between 1 and 32, which identifies the interval for which the set of statistics is available. The number 1 identifies the most recently completed interval, and the interval identified by N is the interval immediately preceding the one identified by N-1.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

sonusSonetLineFailureIntervalFCs 1.3.6.1.4.1.2879.2.4.3.1.3.7.1.3
The counter associated with the number of Failures encountered by a SONET/SDH Line in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfCurrentCount  

sonusSonetFarEndLineFailureCurrentTable 1.3.6.1.4.1.2879.2.4.3.1.3.8
The Sonus SONET Far End Line Failure Current table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SonusSonetFarEndLineFailureCurrentEntry

sonusSonetFarEndLineFailureCurrentEntry 1.3.6.1.4.1.2879.2.4.3.1.3.8.1
An entry in the Sonus SONET Far End Line Failure Current table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SonusSonetFarEndLineFailureCurrentEntry  

sonusSonetFarEndLineFailureCurrentIfIndex 1.3.6.1.4.1.2879.2.4.3.1.3.8.1.1
The ifIndex assigned to this port when it was created. This will not change until the port is deleted.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

sonusSonetFarEndLineFailureCurrentFCs 1.3.6.1.4.1.2879.2.4.3.1.3.8.1.2
The counter associated with the number of Failures encountered by a SONET/SDH Line in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfCurrentCount  

sonusSonetFarEndLineFailureIntervalTable 1.3.6.1.4.1.2879.2.4.3.1.3.9
The Sonus SONET Far End Line Failure Interval table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SonusSonetFarEndLineFailureIntervalEntry

sonusSonetFarEndLineFailureIntervalEntry 1.3.6.1.4.1.2879.2.4.3.1.3.9.1
An entry in the Sonus SONET Far End Line Failure Interval table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SonusSonetFarEndLineFailureIntervalEntry  

sonusSonetFarEndLineFailureIntervalIfIndex 1.3.6.1.4.1.2879.2.4.3.1.3.9.1.1
The ifIndex assigned to this port when it was created. This will not change until the port is deleted.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

sonusSonetFarEndLineFailureIntervalNumber 1.3.6.1.4.1.2879.2.4.3.1.3.9.1.2
A number between 1 and 32, which identifies the interval for which the set of statistics is available. The number 1 identifies the most recently completed interval, and the interval identified by N is the interval immediately preceding the one identified by N-1.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

sonusSonetFarEndLineFailureIntervalFCs 1.3.6.1.4.1.2879.2.4.3.1.3.9.1.3
The counter associated with the number of Failures encountered by a SONET/SDH Line in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfCurrentCount  

sonusSonetLayer 1.3.6.1.4.1.2879.2.4.3.1.4
OBJECT IDENTIFIER    

sonusSonetLayerTable 1.3.6.1.4.1.2879.2.4.3.1.4.1
The SONET layer table. This table maps SONET Interface ifIndex to a shelf, slot, and port.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SonusSonetLayerEntry

sonusSonetLayerEntry 1.3.6.1.4.1.2879.2.4.3.1.4.1.1
An entry in the SONET layer table. This entry maps the ifIndex of the SONET Interface to a shelf, slot and port. A row is added to this table when a SONET port is created.
Status: current Access: not-accessible
OBJECT-TYPE    
  SonusSonetLayerEntry  

sonusSonetLayerShelfIndex 1.3.6.1.4.1.2879.2.4.3.1.4.1.1.1
Shelf index for this table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SonusShelfIndex  

sonusSonetLayerSlotIndex 1.3.6.1.4.1.2879.2.4.3.1.4.1.1.2
Slot index for this table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SonusSlotIndex  

sonusSonetLayerPortIndex 1.3.6.1.4.1.2879.2.4.3.1.4.1.1.3
Port index for this table.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

sonusSonetLayerIfIndex 1.3.6.1.4.1.2879.2.4.3.1.4.1.1.4
The ifIndex assigned to this shelf, slot, and port when the SONET Interface was created.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sonusSonetLayerRowStatus 1.3.6.1.4.1.2879.2.4.3.1.4.1.1.5
This object is used to create, delete, or modify a row in this table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

sonusSonetObjectsPath 1.3.6.1.4.1.2879.2.4.3.2
OBJECT IDENTIFIER    

sonusSonetPathAdmn 1.3.6.1.4.1.2879.2.4.3.2.1
OBJECT IDENTIFIER    

sonusSonetPathAdmnTable 1.3.6.1.4.1.2879.2.4.3.2.1.1
The Sonus SONET Path Admn Table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SonusSonetPathAdmnEntry

sonusSonetPathAdmnEntry 1.3.6.1.4.1.2879.2.4.3.2.1.1.1
An entry in the Sonus SONET Path Admn table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SonusSonetPathAdmnEntry  

sonusSonetPathAdmnIfIndex 1.3.6.1.4.1.2879.2.4.3.2.1.1.1.1
The ifIndex assigned to this path when it was created. This will not change until the path is deleted.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

sonusSonetPathAdmnShelfIndex 1.3.6.1.4.1.2879.2.4.3.2.1.1.1.2
Shelf index for this table.
Status: current Access: read-write
OBJECT-TYPE    
  SonusShelfIndex  

sonusSonetPathAdmnSlotIndex 1.3.6.1.4.1.2879.2.4.3.2.1.1.1.3
Slot index for this table.
Status: current Access: read-write
OBJECT-TYPE    
  SonusSlotIndex  

sonusSonetPathAdmnPortIndex 1.3.6.1.4.1.2879.2.4.3.2.1.1.1.4
OC3 port index for this table.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..4  

sonusSonetPathAdmnPathIndex 1.3.6.1.4.1.2879.2.4.3.2.1.1.1.5
STS1 path index for this table.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..3  

sonusSonetPathAdmnRowStatus 1.3.6.1.4.1.2879.2.4.3.2.1.1.1.6
This object is used to create, delete, or modify a row in this table.
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

sonusSonetPathAdmnState 1.3.6.1.4.1.2879.2.4.3.2.1.1.1.7
State of STS1, Enabled/Disabled
Status: current Access: read-write
OBJECT-TYPE    
  SonusAdminState  

sonusSonetPathAdmnMode 1.3.6.1.4.1.2879.2.4.3.2.1.1.1.8
STS1 in-service/out-of-service.
Status: current Access: read-write
OBJECT-TYPE    
  SonusServiceState  

sonusSonetPathAdmnAction 1.3.6.1.4.1.2879.2.4.3.2.1.1.1.9
The type of action to perform when a SONET path is taken out of service. The SONET path can be dried up, or it can be forced out of service.
Status: current Access: read-write
OBJECT-TYPE    
  SonusAdminAction  

sonusSonetPathAdmnTimeout 1.3.6.1.4.1.2879.2.4.3.2.1.1.1.10
The Dryup Timeout specifies the maximum amount of time to wait for all active calls to terminate on a SONET path before the path should be taken out-of-service.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..1440  

sonusSonetPathAdmnStatAction 1.3.6.1.4.1.2879.2.4.3.2.1.1.1.11
Initialize Performance Monitoring Statistics. A PM initialization action initiates one request for the action. Requests to initialize more than one group of statistics can be accomplished by OR-ing the appropriate bits (e.g., to initialize all 15 minute PM statistics, set bits 1 and 2). Reading this variable always returns zero.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER init15MinuteNearEnd(1), init15MinuteFarEnd(2), init24HourNearEnd(4), init24HourFarEnd(8)  

sonusSonetPathAdmnRDIMode 1.3.6.1.4.1.2879.2.4.3.2.1.1.1.12
The desired type of SONET port Path Remote Defect Indication to use. (1) normal - Use one-bit RDI-P signalling using bit 5 of G1. (2) enhanced - Use three-bit RDI-P (ERDI-P) using bits 5-7 of G1.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER normal(1), enhanced(2)  

sonusSonetPathAdmnTraceState 1.3.6.1.4.1.2879.2.4.3.2.1.1.1.13
The desired state of SONET Path Trace. (1) enabled - Enables the generation of SONET Path Trace Messages in the J1 bytes of the STS Path overhead, and enables the reception and checking of received Path Trace Messages with the Expected Path Trace Message. (2) disabled - Transmits all zero's in the J1 bytes of the STS Path overhead, and disables the reception and checking of received Path Trace Messages with the Expected Path Trace Message.
Status: current Access: read-write
OBJECT-TYPE    
  SonusAdminState  

sonusSonetPathAdmnTraceExpMsg 1.3.6.1.4.1.2879.2.4.3.2.1.1.1.14
The expected path trace string to be received on the SONET port in the J1 bytes of the STS Path overhead.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..61)  

sonusSonetPathAdmnTraceXmtMsg 1.3.6.1.4.1.2879.2.4.3.2.1.1.1.15
The path trace string to be transmitted on the SONET port in the J1 bytes of the STS Path overhead.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..61)  

sonusSonetPathAdmnTraceRcvMsg 1.3.6.1.4.1.2879.2.4.3.2.1.1.1.16
The path trace string received on the SONET port in the J1 bytes of the STS Path overhead.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..61)  

sonusSonetPathAdmnOperStatus 1.3.6.1.4.1.2879.2.4.3.2.1.1.1.17
The actual status of the Sonet path. Path is Up if it is administratively in service and there are no line failures or hardware failures. Path is Down if it is administratively in service and there are line failures or hardware failures, or if it is administratively out of service. Path is DryingUp if it is administratively out of service and is drying up (no new calls, still carrying in-progress calls) THE OTHER VALUES ARE NO LONGER SUPPORTED.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enabledInService(1), enabledOutOfService(2), enabledDown(3), dryingUp(4), disabled(5), up(6), down(7)  

sonusSonetPathAdmnDs3ModeOverride 1.3.6.1.4.1.2879.2.4.3.2.1.1.1.18
This flag controls whether the mode and state of the DS3 carried in the Path are modified when the mode and state of the Path is modified. If this flag is set to Enabled, the DS3 state and mode are not changed when the Path mode and state are changed.
Status: current Access: read-write
OBJECT-TYPE    
  SonusAdminState  

sonusSonetPath 1.3.6.1.4.1.2879.2.4.3.2.2
OBJECT IDENTIFIER    

sonusSonetPathThresholdTable 1.3.6.1.4.1.2879.2.4.3.2.2.1
The Sonus SONET Path Threshold Table. This table adds objects to set the Performance Monitoring thresholds for generating a Threshold Crossing Alert.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SonusSonetPathThresholdEntry

sonusSonetPathThresholdEntry 1.3.6.1.4.1.2879.2.4.3.2.2.1.1
An entry in the Sonus SONET Path Threshold table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SonusSonetPathThresholdEntry  

sonusSonetPathThresholdIfIndex 1.3.6.1.4.1.2879.2.4.3.2.2.1.1.1
The ifIndex assigned to this path when it was created. This will not change until the path is deleted.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

sonusSonetPathThresholdPathIndex 1.3.6.1.4.1.2879.2.4.3.2.2.1.1.2
STS1 path index for this table.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..3  

sonusSonetPathThreshold15mCVs 1.3.6.1.4.1.2879.2.4.3.2.2.1.1.3
Threshold for 15 minute interval Path layer Coding Violations.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..16383  

sonusSonetPathThreshold15mESs 1.3.6.1.4.1.2879.2.4.3.2.2.1.1.4
Threshold for 15 minute interval Path layer Errored Seconds.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..900  

sonusSonetPathThreshold15mSESs 1.3.6.1.4.1.2879.2.4.3.2.2.1.1.5
Threshold for 15 minute interval Path layer Severely Errored Seconds.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..900  

sonusSonetPathThreshold15mUASs 1.3.6.1.4.1.2879.2.4.3.2.2.1.1.6
Threshold for 15 minute interval Path layer Unavailable Seconds.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..900  

sonusSonetPathThreshold24hCVs 1.3.6.1.4.1.2879.2.4.3.2.2.1.1.7
Threshold for 24 hour interval Path layer Coding Violations.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..1048575  

sonusSonetPathThreshold24hESs 1.3.6.1.4.1.2879.2.4.3.2.2.1.1.8
Threshold for 24 hour interval Path layer Errored Seconds.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..65535  

sonusSonetPathThreshold24hSESs 1.3.6.1.4.1.2879.2.4.3.2.2.1.1.9
Threshold for 24 hour interval Path layer Severely Errored Seconds.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..65535  

sonusSonetPathThreshold24hUASs 1.3.6.1.4.1.2879.2.4.3.2.2.1.1.10
Threshold for 24 hour interval Path layer Unavailable Seconds.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..65535  

sonusSonetPathCurrentTable 1.3.6.1.4.1.2879.2.4.3.2.2.2
The Sonus SONET Path Current table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SonusSonetPathCurrentEntry

sonusSonetPathCurrentEntry 1.3.6.1.4.1.2879.2.4.3.2.2.2.1
An entry in the Sonus SONET Path Current table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SonusSonetPathCurrentEntry  

sonusSonetPathCurrentIfIndex 1.3.6.1.4.1.2879.2.4.3.2.2.2.1.1
The ifIndex assigned to this path when it was created. This will not change until the path is deleted.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

sonusSonetPathCurrentPathIndex 1.3.6.1.4.1.2879.2.4.3.2.2.2.1.2
STS1 path index for this table.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..3  

sonusSonetPathCurrentWidth 1.3.6.1.4.1.2879.2.4.3.2.2.2.1.3
A value that indicates the type of the SONET/SDH Path. For SONET, the assigned types are the STS-Nc SPEs, where N = 1, 3, 12, 24, and 48. STS-1 is equal to 51.84 Mbps. For SDH, the assigned types are the STM-Nc VCs, where N = 1, 4, and 16.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER sts1(1), sts3cSTM1(2), sts12cSTM4(3), sts24c(4), sts48cSTM16(5)  

sonusSonetPathCurrentStatus 1.3.6.1.4.1.2879.2.4.3.2.2.2.1.4
This variable indicates the status of the interface. It is a bit map represented as a sum, therefore, it can represent multiple defects simultaneously. The sonetPathNoDefect should be set if and only if no other flag is set. The various bit positions are: 1 sonetPathNoDefect 2 sonetPathSTSLOP 4 sonetPathSTSAIS 8 sonetPathSTSRDI 16 sonetPathUnequiped 32 sonetPathSignalLabelMismatch
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..62  

sonusSonetPathCurrentESs 1.3.6.1.4.1.2879.2.4.3.2.2.2.1.5
The counter associated with the number of Errored Seconds encountered by a SONET/SDH Path in the current 24 hour interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfCurrentCount  

sonusSonetPathCurrentSESs 1.3.6.1.4.1.2879.2.4.3.2.2.2.1.6
The counter associated with the number of Severely Errored Seconds encountered by a SONET/SDH Path in the current 24 hour interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfCurrentCount  

sonusSonetPathCurrentUASs 1.3.6.1.4.1.2879.2.4.3.2.2.2.1.7
The counter associated with the number of Unavailable Seconds encountered by a SONET/SDH Path in the current 24 hour interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfCurrentCount  

sonusSonetPathCurrentCVs 1.3.6.1.4.1.2879.2.4.3.2.2.2.1.8
The counter associated with the number of Coding Violations encountered by a SONET/SDH Path in the current 24 hour interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfCurrentCount  

sonusSonetPathCurrentFCs 1.3.6.1.4.1.2879.2.4.3.2.2.2.1.9
The counter associated with the number of Failures encountered by a SONET/SDH Path in the current 24 hour interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfCurrentCount  

sonusSonetPathCurrentTraceStatus 1.3.6.1.4.1.2879.2.4.3.2.2.2.1.10
The status of the Trace Mismatch Failure.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER nodefect(1), tracemismatch(2)  

sonusSonetPathIntervalTable 1.3.6.1.4.1.2879.2.4.3.2.2.3
The Sonus SONET Path Interval table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SonusSonetPathIntervalEntry

sonusSonetPathIntervalEntry 1.3.6.1.4.1.2879.2.4.3.2.2.3.1
An entry in the Sonus SONET Path Interval table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SonusSonetPathIntervalEntry  

sonusSonetPathIntervalIfIndex 1.3.6.1.4.1.2879.2.4.3.2.2.3.1.1
The ifIndex assigned to this path when it was created. This will not change until the path is deleted.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

sonusSonetPathIntervalPathIndex 1.3.6.1.4.1.2879.2.4.3.2.2.3.1.2
STS1 path index for this table.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..3  

sonusSonetPathIntervalNumber 1.3.6.1.4.1.2879.2.4.3.2.2.3.1.3
The number 1 identifies the most recently completed 24 hour interval. In the future if more 24 hour intervals are supported, the interval identified by N is the interval immediately preceding the one identified by N-1.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1  

sonusSonetPathIntervalESs 1.3.6.1.4.1.2879.2.4.3.2.2.3.1.4
The counter associated with the number of Errored Seconds encountered by a SONET/SDH Path in the previous 24 hour interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfIntervalCount  

sonusSonetPathIntervalSESs 1.3.6.1.4.1.2879.2.4.3.2.2.3.1.5
The counter associated with the number of Severely Errored Seconds encountered by a SONET/SDH Path in the previous 24 hour interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfIntervalCount  

sonusSonetPathIntervalUASs 1.3.6.1.4.1.2879.2.4.3.2.2.3.1.6
The counter associated with the number of Unavailable Seconds encountered by a SONET/SDH Path in the previous 24 hour interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfIntervalCount  

sonusSonetPathIntervalCVs 1.3.6.1.4.1.2879.2.4.3.2.2.3.1.7
The counter associated with the number of Coding Violations encountered by a SONET/SDH Path in the previous 24 hour interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfIntervalCount  

sonusSonetPathIntervalFCs 1.3.6.1.4.1.2879.2.4.3.2.2.3.1.8
The counter associated with the number of Failures encountered by a SONET/SDH Path in the previous 24 hour interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfIntervalCount  

sonusSonetPathIntervalValidData 1.3.6.1.4.1.2879.2.4.3.2.2.3.1.9
This variable indicates if the data for this interval is valid.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

sonusSonetFarEndPathCurrentTable 1.3.6.1.4.1.2879.2.4.3.2.2.4
The Sonus SONET Far End Path Current table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SonusSonetFarEndPathCurrentEntry

sonusSonetFarEndPathCurrentEntry 1.3.6.1.4.1.2879.2.4.3.2.2.4.1
An entry in the Sonus SONET Far End Path Current table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SonusSonetFarEndPathCurrentEntry  

sonusSonetFarEndPathCurrentIfIndex 1.3.6.1.4.1.2879.2.4.3.2.2.4.1.1
The ifIndex assigned to this path when it was created. This will not change until the path is deleted.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

sonusSonetFarEndPathCurrentPathIndex 1.3.6.1.4.1.2879.2.4.3.2.2.4.1.2
STS1 path index for this table.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..3  

sonusSonetFarEndPathCurrentESs 1.3.6.1.4.1.2879.2.4.3.2.2.4.1.3
The counter associated with the number of Far End Errored Seconds encountered by a SONET/SDH Path in the current 24 hour interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfCurrentCount  

sonusSonetFarEndPathCurrentSESs 1.3.6.1.4.1.2879.2.4.3.2.2.4.1.4
The counter associated with the number of Far End Severely Errored Seconds encountered by a SONET/SDH Path in the current 24 hour interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfCurrentCount  

sonusSonetFarEndPathCurrentUASs 1.3.6.1.4.1.2879.2.4.3.2.2.4.1.5
The counter associated with the number of Far End Unavailable Seconds encountered by a SONET/SDH Path in the current 24 hour interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfCurrentCount  

sonusSonetFarEndPathCurrentCVs 1.3.6.1.4.1.2879.2.4.3.2.2.4.1.6
The counter associated with the number of Far End Coding Violations encountered by a SONET/SDH Path in the current 24 hour interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfCurrentCount  

sonusSonetFarEndPathCurrentFCs 1.3.6.1.4.1.2879.2.4.3.2.2.4.1.7
The counter associated with the number of Far End Failures encountered by a SONET/SDH Path in the current 24 hour interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfCurrentCount  

sonusSonetFarEndPathIntervalTable 1.3.6.1.4.1.2879.2.4.3.2.2.5
The Sonus SONET Far End Path Interval table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SonusSonetFarEndPathIntervalEntry

sonusSonetFarEndPathIntervalEntry 1.3.6.1.4.1.2879.2.4.3.2.2.5.1
An entry in the Sonus SONET Far End Path Interval table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SonusSonetFarEndPathIntervalEntry  

sonusSonetFarEndPathIntervalIfIndex 1.3.6.1.4.1.2879.2.4.3.2.2.5.1.1
The ifIndex assigned to this path when it was created. This will not change until the path is deleted.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

sonusSonetFarEndPathIntervalPathIndex 1.3.6.1.4.1.2879.2.4.3.2.2.5.1.2
STS1 path index for this table.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..3  

sonusSonetFarEndPathIntervalNumber 1.3.6.1.4.1.2879.2.4.3.2.2.5.1.3
The number 1 identifies the most recently completed 24 hour interval. In the future if more 24 hour intervals are supported, the interval identified by N is the interval immediately preceding the one identified by N-1.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1  

sonusSonetFarEndPathIntervalESs 1.3.6.1.4.1.2879.2.4.3.2.2.5.1.4
The counter associated with the number of Far End Errored Seconds encountered by a SONET/SDH Path in the current 24 hour interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfIntervalCount  

sonusSonetFarEndPathIntervalSESs 1.3.6.1.4.1.2879.2.4.3.2.2.5.1.5
The counter associated with the number of Far End Severely Errored Seconds encountered by a SONET/SDH Path in the current 24 hour interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfIntervalCount  

sonusSonetFarEndPathIntervalUASs 1.3.6.1.4.1.2879.2.4.3.2.2.5.1.6
The counter associated with the number of Far End Unavailable Seconds encountered by a SONET/SDH Path in the current 24 hour interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfIntervalCount  

sonusSonetFarEndPathIntervalCVs 1.3.6.1.4.1.2879.2.4.3.2.2.5.1.7
The counter associated with the number of Far End Coding Violations encountered by a SONET/SDH Path in the current 24 hour interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfIntervalCount  

sonusSonetFarEndPathIntervalFCs 1.3.6.1.4.1.2879.2.4.3.2.2.5.1.8
The counter associated with the number of Far End Failures encountered by a SONET/SDH Path in the current 24 hour interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfIntervalCount  

sonusSonetFarEndPathIntervalValidData 1.3.6.1.4.1.2879.2.4.3.2.2.5.1.9
This variable indicates if the data for this interval is valid.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

sonusSonetPathFailureCurrentTable 1.3.6.1.4.1.2879.2.4.3.2.2.6
The Sonus SONET Path Failure Current table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SonusSonetPathFailureCurrentEntry

sonusSonetPathFailureCurrentEntry 1.3.6.1.4.1.2879.2.4.3.2.2.6.1
An entry in the Sonus SONET Path Failure Current table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SonusSonetPathFailureCurrentEntry  

sonusSonetPathFailureCurrentIfIndex 1.3.6.1.4.1.2879.2.4.3.2.2.6.1.1
The ifIndex assigned to this path when it was created. This will not change until the path is deleted.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

sonusSonetPathFailureCurrentPathIndex 1.3.6.1.4.1.2879.2.4.3.2.2.6.1.2
STS1 path index for this table.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..3  

sonusSonetPathFailureCurrentFCs 1.3.6.1.4.1.2879.2.4.3.2.2.6.1.3
The counter associated with the number of Failures encountered by a SONET/SDH Path in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfCurrentCount  

sonusSonetPathFailureCurrentTraceStatus 1.3.6.1.4.1.2879.2.4.3.2.2.6.1.4
The status of the Trace Mismatch Failure.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER nodefect(1), tracemismatch(2)  

sonusSonetPathFailureIntervalTable 1.3.6.1.4.1.2879.2.4.3.2.2.7
The Sonus SONET Path Failure Interval table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SonusSonetPathFailureIntervalEntry

sonusSonetPathFailureIntervalEntry 1.3.6.1.4.1.2879.2.4.3.2.2.7.1
An entry in the Sonus SONET Path Failure Interval table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SonusSonetPathFailureIntervalEntry  

sonusSonetPathFailureIntervalIfIndex 1.3.6.1.4.1.2879.2.4.3.2.2.7.1.1
The ifIndex assigned to this path when it was created. This will not change until the path is deleted.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

sonusSonetPathFailureIntervalPathIndex 1.3.6.1.4.1.2879.2.4.3.2.2.7.1.2
STS1 path index for this table.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..3  

sonusSonetPathFailureIntervalNumber 1.3.6.1.4.1.2879.2.4.3.2.2.7.1.3
A number between 1 and 32, which identifies the interval for which the set of statistics is available. The number 1 identifies the most recently completed interval, and the interval identified by N is the interval immediately preceding the one identified by N-1.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

sonusSonetPathFailureIntervalFCs 1.3.6.1.4.1.2879.2.4.3.2.2.7.1.4
The counter associated with the number of Failures encountered by a SONET/SDH Path in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfCurrentCount  

sonusSonetFarEndPathFailureCurrentTable 1.3.6.1.4.1.2879.2.4.3.2.2.8
The Sonus SONET Far End Path Failure Current table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SonusSonetFarEndPathFailureCurrentEntry

sonusSonetFarEndPathFailureCurrentEntry 1.3.6.1.4.1.2879.2.4.3.2.2.8.1
An entry in the Sonus SONET Far End Path Failure Current table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SonusSonetFarEndPathFailureCurrentEntry  

sonusSonetFarEndPathFailureCurrentIfIndex 1.3.6.1.4.1.2879.2.4.3.2.2.8.1.1
The ifIndex assigned to this path when it was created. This will not change until the path is deleted.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

sonusSonetFarEndPathFailureCurrentPathIndex 1.3.6.1.4.1.2879.2.4.3.2.2.8.1.2
STS1 path index for this table.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..3  

sonusSonetFarEndPathFailureCurrentFCs 1.3.6.1.4.1.2879.2.4.3.2.2.8.1.3
The counter associated with the number of Failures encountered by a SONET/SDH Path in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfCurrentCount  

sonusSonetFarEndPathFailureIntervalTable 1.3.6.1.4.1.2879.2.4.3.2.2.9
The Sonus SONET Far End Path Failure Interval table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SonusSonetFarEndPathFailureIntervalEntry

sonusSonetFarEndPathFailureIntervalEntry 1.3.6.1.4.1.2879.2.4.3.2.2.9.1
An entry in the Sonus SONET Far End Path Failure Interval table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SonusSonetFarEndPathFailureIntervalEntry  

sonusSonetFarEndPathFailureIntervalIfIndex 1.3.6.1.4.1.2879.2.4.3.2.2.9.1.1
The ifIndex assigned to this path when it was created. This will not change until the path is deleted.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

sonusSonetFarEndPathFailureIntervalPathIndex 1.3.6.1.4.1.2879.2.4.3.2.2.9.1.2
STS1 path index for this table.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..3  

sonusSonetFarEndPathFailureIntervalNumber 1.3.6.1.4.1.2879.2.4.3.2.2.9.1.3
A number between 1 and 32, which identifies the interval for which the set of statistics is available. The number 1 identifies the most recently completed interval, and the interval identified by N is the interval immediately preceding the one identified by N-1.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

sonusSonetFarEndPathFailureIntervalFCs 1.3.6.1.4.1.2879.2.4.3.2.2.9.1.4
The counter associated with the number of Failures encountered by a SONET/SDH Path in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfCurrentCount  

sonusSonetNextIndex 1.3.6.1.4.1.2879.2.4.3.3
The next valid index to use when creating an entry in the sonusSonetTable.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sonusSonetMIBNotifications 1.3.6.1.4.1.2879.2.4.3.4
OBJECT IDENTIFIER    

sonusSonetMIBNotificationsPrefix 1.3.6.1.4.1.2879.2.4.3.4.0
OBJECT IDENTIFIER    

sonusSonetMIBNotificationsObjects 1.3.6.1.4.1.2879.2.4.3.4.1
OBJECT IDENTIFIER    

sonusSonetAdminStatus 1.3.6.1.4.1.2879.2.4.3.4.1.1
The administrative status of a Sonet port. EnabledInService means the port configuration is applied and the port is available to carry calls. EnabledOutOfService means the port configuration is applied and the port is not available to carry calls. Disabled means the port configuration is not applied and the port is not available to carry calls. DryingUp means the port is still carrying in-progress calls but is not available for new calls. Value deleted is NO LONGER SUPPORTED.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enabledInService(1), enabledOutOfService(2), disabled(3), deleted(4), dryingUp(5)  

sonusSonetOperStatus 1.3.6.1.4.1.2879.2.4.3.4.1.2
Operational status of the Sonet port. Port is inService if the admin state is enabled and the admin mode is in service. Port is outOfService if admin state is enabled, admin mode is out of service, and port is no longer carrying calls (dried up). Port is dryingUp if admin state is enabled, admin mode is out of service, and port is drying up (no new calls, still carrying in-progress calls). Port is inServiceDown if admin state is enabled, admin mode is in service, but physical link is not available due to alarm condition. Port is outOfServiceDown if admin state is enabled, admin mode is out of service, but physical link is not available due to alarm condition. Port is disabled if admin state is disabled, admin mode is out of service, and port is no longer carrying calls (dried up).
Status: obsolete Access: read-only
OBJECT-TYPE    
  INTEGER inService(1), outOfService(2), dryingUp(3), inServiceDown(4), outOfServiceDown(5), disabled(6)  

sonusSonetAlarmStatus 1.3.6.1.4.1.2879.2.4.3.4.1.3
Alarm conditions.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER los(1), losClear(2), lof(3), lofClear(4), lAIS(5), lAISClear(6), lRFI(7), lRFIClear(8), pAIS(9), pAISClear(10), pRFI(11), pRFIClear(12), pLOP(13), pLOPClear(14), pUNEQ(15), pUNEQClear(16), pPLM(17), pPLMClear(18), pTIM(19), pTIMClear(20)  

sonusSonetThresholdType 1.3.6.1.4.1.2879.2.4.3.4.1.4
Threshold crossing types.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER sectionNearendCodingViolation15min(1), sectionNearendErroredSec15min(2), sectionNearendSeverelyErroredSec15min(3), sectionNearendSeverelyErroredFrameSec15min(4), lineNearendCodingViolation15min(5), lineNearendErroredSec15min(6), lineNearendSeverelyErroredSec15min(7), lineNearendUnavailableSec15min(8), pathNearendCodingViolation15min(9), pathNearendErroredSec15min(10), pathNearendSeverelyErroredSec15min(11), pathNearendUnavailableSec15min(12), sectionNearendCodingViolation24hr(13), sectionNearendErroredSec24hr(14), sectionNearendSeverelyErroredSec24hr(15), sectionNearendSeverelyErroredFrameSec24hr(16), lineNearendCodingViolation24hr(17), lineNearendErroredSec24hr(18), lineNearendSeverelyErroredSec24hr(19), lineNearendUnavailableSec24hr(20), pathNearendCodingViolation24hr(21), pathNearendErroredSec24hr(22), pathNearendSeverelyErroredSec24hr(23), pathNearendUnavailableSec24hr(24), lineFarendCodingViolation15min(25), lineFarendErroredSec15min(26), lineFarendSeverelyErroredSec15min(27), lineFarendUnavailableSec15min(28), pathFarendCodingViolation15min(29), pathFarendErroredSec15min(30), pathFarendSeverelyErroredSec15min(31), pathFarendUnavailableSec15min(32), sectionFarendCodingViolation24hr(33), sectionFarendErroredSec24hr(34), sectionFarendSeverelyErroredSec24hr(35), sectionFarendSeverelyErroredFrameSec24hr(36), lineFarendCodingViolation24hr(37), lineFarendErroredSec24hr(38), lineFarendSeverelyErroredSec24hr(39), lineFarendUnavailableSec24hr(40), pathFarendCodingViolation24hr(41), pathFarendErroredSec24hr(42), pathFarendSeverelyErroredSec24hr(43), pathFarendUnavailableSec24hr(44)  

sonusPathIndex 1.3.6.1.4.1.2879.2.4.3.4.1.5
STS1 path index.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..3  

sonusSonetOutOfServiceReason 1.3.6.1.4.1.2879.2.4.3.4.1.6
Reason the Sonet port/path went out of service.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER admin(1), hwFailure(2)  

sonusSonetPortAdminStatusNotification 1.3.6.1.4.1.2879.2.4.3.4.0.1
This trap indicates the Sonet port's administrative status has changed due to an operator-initiated command. Possible admin status is EnabledInService, EnabledOutOfService, Disabled, and DryingUp.
Status: current Access: read-only
NOTIFICATION-TYPE    

sonusSonetPortOperStatusNotification 1.3.6.1.4.1.2879.2.4.3.4.0.2
NO LONGER SUPPORTED. This trap indicates the Sonet port's operational status has changed.
Status: obsolete Access: read-only
NOTIFICATION-TYPE    

sonusSonetLineAlarmNotification 1.3.6.1.4.1.2879.2.4.3.4.0.3
This trap indicates the line Section/Line-layer alarm state of the Sonet port has changed.
Status: current Access: read-only
NOTIFICATION-TYPE    

sonusSonetLineThresholdCrossNotification 1.3.6.1.4.1.2879.2.4.3.4.0.4
This trap indicates that a Section/Line-layer performance monitoring threshold has been crossed.
Status: current Access: read-only
NOTIFICATION-TYPE    

sonusSonetPathAdminStatusNotification 1.3.6.1.4.1.2879.2.4.3.4.0.5
This trap indicates the Sonet path's administrative status has changed due to an operator-initiated command. Possible admin status is EnabledInService, EnabledOutOfService, Disabled, and DryingUp.
Status: current Access: read-only
NOTIFICATION-TYPE    

sonusSonetPathOperStatusNotification 1.3.6.1.4.1.2879.2.4.3.4.0.6
NO LONGER SUPPORTED. This trap indicates the Sonet path's operational status has changed.
Status: obsolete Access: read-only
NOTIFICATION-TYPE    

sonusSonetPathAlarmNotification 1.3.6.1.4.1.2879.2.4.3.4.0.7
This trap indicates the line Path-layer alarm state of the Sonet path has changed.
Status: current Access: read-only
NOTIFICATION-TYPE    

sonusSonetPathThresholdCrossNotification 1.3.6.1.4.1.2879.2.4.3.4.0.8
This trap indicates that a Path-layer performance monitoring threshold has been crossed.
Status: current Access: read-only
NOTIFICATION-TYPE    

sonusSonetPortOutOfServiceNotification 1.3.6.1.4.1.2879.2.4.3.4.0.9
This trap indicates the Sonet port went out of service. Reason indicates why the port went out of service. Possible reasons include admin or hardware failure.
Status: current Access: read-only
NOTIFICATION-TYPE    

sonusSonetPathOutOfServiceNotification 1.3.6.1.4.1.2879.2.4.3.4.0.10
This trap indicates the Sonet path went out of service. Reason indicates why the port went out of service. Possible reasons include admin or hardware failure.
Status: current Access: read-only
NOTIFICATION-TYPE