SNI-SERVER-CONTROL-MIB

File: SNI-SERVER-CONTROL-MIB.mib (165740 bytes)

Imported modules

RFC-1212 RFC1213-MIB RFC1155-SMI

Imported symbols

OBJECT-TYPE mib-2 Counter
Gauge IpAddress

Defined Types

DisplayString  
OCTET STRING    

PhysAddress  
OCTET STRING    

TemperatureSensors  
SEQUENCE    
  tempCabinetId INTEGER
  tempSensorNumber INTEGER
  tempSensorStatus INTEGER
  tempSensorPurpose INTEGER
  tempLowerWarningLevel INTEGER
  tempUpperWarningLevel INTEGER
  tempLowerCriticalLevel INTEGER
  tempUpperCriticalLevel INTEGER
  tempLowerDamageLevel INTEGER
  tempUpperDamageLevel INTEGER
  tempCurrentValue Gauge
  tempCriticalReaction INTEGER
  tempSensorDesignation DisplayString

Fans  
SEQUENCE    
  fanCabinetId INTEGER
  fanNumber INTEGER
  fanStatus INTEGER
  fanPurpose INTEGER
  fanPositionX INTEGER
  fanPositionY INTEGER
  fanPositionZ INTEGER
  fanCurrentSpeed Gauge
  fanNominalMaximumSpeed INTEGER
  fanCurrentMaximumSpeed Gauge
  fanMaximumSpeedCriticalLevel INTEGER
  fanMinimumSpeed INTEGER
  fanFailReaction INTEGER
  fanFailShutdownDelay INTEGER
  fanDesignation DisplayString
  fanIdentification DisplayString

EventLog  
SEQUENCE    
  eventLogEntryNumber INTEGER
  eventLogMessageData OCTET STRING

ErrorLog  
SEQUENCE    
  errorLogEntryNumber INTEGER
  errorLogMessageData OCTET STRING

Cpu  
SEQUENCE    
  cpuTableIndex INTEGER
  cpuType INTEGER
  cpuFrequency INTEGER
  cpuStep INTEGER
  cpuStatus INTEGER
  cpuModel INTEGER
  cpuName DisplayString
  cpuSocketDesignation DisplayString
  cpuManufacturer DisplayString
  cpuNrLogicalsPerPhysical INTEGER
  cpuCacheL1Size INTEGER
  cpuCacheL2Size INTEGER
  cpuCacheL3Size INTEGER
  cpuNrCoresPerPhysical INTEGER

MemoryModules  
SEQUENCE    
  memModuleNumber INTEGER
  memModuleBank INTEGER
  memModuleStatus INTEGER
  memModuleErrors Counter
  memModuleStartAddress INTEGER
  memModuleSize INTEGER
  memModuleType INTEGER
  memModuleType2 INTEGER
  memModuleSocketDesignation DisplayString
  memModuleCorrectableErrors Counter
  memModuleApproved INTEGER
  memModuleStartAddressMB INTEGER
  memModuleSizeMB INTEGER

PciUtilization  
SEQUENCE    
  pciUtilBusNumber INTEGER
  pciUtilBusLoad Gauge
  pciUtilBusTransferRate Gauge
  pciUtilBusEfficiency Gauge

PagerUser  
SEQUENCE    
  pagerUserIndex INTEGER
  pagerType INTEGER
  pagerUserName DisplayString
  pagerUserDescription DisplayString
  pagerActive INTEGER
  pagerNumber DisplayString
  pagerServiceProviderNumber DisplayString
  pagerActivityPrompt DisplayString
  pagerTimeModel DisplayString

OnOffTimes  
SEQUENCE    
  onOffWeekday INTEGER
  onTime INTEGER
  offTime INTEGER

CabinetInfos  
SEQUENCE    
  cabinetId INTEGER
  cabinetLocation DisplayString
  cabinetIdentNumber DisplayString
  cabinetSystemName DisplayString
  cabinetNumberFans INTEGER
  cabinetNumberTempSensors INTEGER
  cabinetNumberPowerSupplies INTEGER
  cabinetPowerSupplySlots INTEGER
  cabinetUpsUsed INTEGER
  cabinetBoardSerialNumber DisplayString
  cabinetBoardRevision INTEGER
  cabinetBoardId DisplayString
  cabinetManagementControllerType DisplayString
  cabinetControllerFirmwareMajor INTEGER
  cabinetControllerFirmwareMinor INTEGER
  cabinetAttribute INTEGER
  cabinetPowerOnStatus INTEGER
  cabinetStatusSummary INTEGER
  cabinetLastPoweroffSource INTEGER
  cabinetActionAfterAcFail INTEGER
  cabinetBbuUsed INTEGER
  cabinetSystemType INTEGER
  cabinetStatusDetail INTEGER
  cabinetHousingType DisplayString
  cabinetFrontDoorStatus INTEGER
  cabinetHousingOpenStatus INTEGER
  sieScCabinetNumberVoltages INTEGER
  sieScCabinetControllerFirmware DisplayString
  sieScCabinetBoardRevisionString DisplayString
  sieScCabinetAdministrativeURL DisplayString
  sieScRemcsId DisplayString

PowerSupplies  
SEQUENCE    
  powerSupplyCabinetId INTEGER
  powerSupplyStatus INTEGER
  powerSupplyRedundancy INTEGER

PowerSupplyUnits  
SEQUENCE    
  powerSupplyUnitCabinetId INTEGER
  powerSupplyUnitNumber INTEGER
  powerSupplyUnitStatus INTEGER
  powerSupplyUnitDesignation DisplayString

SniScVoltages  
SEQUENCE    
  sniScVoltageCabinetNumber INTEGER
  sniScVoltageNumber INTEGER
  sniScVoltageStatus INTEGER
  sniScVoltageDesignation DisplayString
  sniScVoltageMinimumValue INTEGER
  sniScVoltageMaximumValue INTEGER
  sniScVoltageCurrentValue Gauge
  sniScVoltageNominalValue INTEGER
  sniScVoltageOutputLoad Gauge

UpsInfos  
SEQUENCE    
  upsNumber INTEGER
  upsDetected INTEGER
  upsDischargeTime INTEGER
  upsVendor DisplayString
  upsType DisplayString
  upsOemAgent DisplayString
  upsOemAgentAddress IpAddress
  upsTimeOnBatterySeconds Counter

InterfaceParameters  
SEQUENCE    
  interfaceCabinetId INTEGER
  interfaceNumber INTEGER
  interfaceType INTEGER
  ipAddress IpAddress
  ipAdressNetMask IpAddress
  physicalAddress PhysAddress
  phoneNumber DisplayString
  interfaceChannelType INTEGER
  dhcpConfigured INTEGER
  controllerType DisplayString
  controllerModel DisplayString
  controllerFWVersion DisplayString

ServiceComponents  
SEQUENCE    
  serviceComponentProcessorId INTEGER
  serviceComponentId INTEGER
  serviceComponentName DisplayString
  serviceComponentType INTEGER
  serviceComponentStatus INTEGER

Defined Values

enterprises 1.3.6.1.4.1
OBJECT IDENTIFIER    

sni 1.3.6.1.4.1.231
OBJECT IDENTIFIER    

sniProductMibs 1.3.6.1.4.1.231.2
OBJECT IDENTIFIER    

sniExtensions 1.3.6.1.4.1.231.2.10
OBJECT IDENTIFIER    

sniServerMgmt 1.3.6.1.4.1.231.2.10.2
OBJECT IDENTIFIER    

sniInventory 1.3.6.1.4.1.231.2.10.2.1
OBJECT IDENTIFIER    

sniCommon 1.3.6.1.4.1.231.2.10.2.2
OBJECT IDENTIFIER    

sniBios 1.3.6.1.4.1.231.2.10.2.2.1
OBJECT IDENTIFIER    

sniEisa 1.3.6.1.4.1.231.2.10.2.2.2
OBJECT IDENTIFIER    

sniHd 1.3.6.1.4.1.231.2.10.2.2.3
OBJECT IDENTIFIER    

sniBus 1.3.6.1.4.1.231.2.10.2.2.4
OBJECT IDENTIFIER    

sniServerControl 1.3.6.1.4.1.231.2.10.2.2.5
OBJECT IDENTIFIER    

sniPcSpecific 1.3.6.1.4.1.231.2.10.2.3
OBJECT IDENTIFIER    

sniScb 1.3.6.1.4.1.231.2.10.2.4
OBJECT IDENTIFIER    

sniOsSpecific 1.3.6.1.4.1.231.2.10.2.5
OBJECT IDENTIFIER    

sniNetware 1.3.6.1.4.1.231.2.10.2.5.1
OBJECT IDENTIFIER    

sniWinNt 1.3.6.1.4.1.231.2.10.2.5.2
OBJECT IDENTIFIER    

sniOs2 1.3.6.1.4.1.231.2.10.2.5.3
OBJECT IDENTIFIER    

sniUnix 1.3.6.1.4.1.231.2.10.2.5.4
OBJECT IDENTIFIER    

sniOemComponents 1.3.6.1.4.1.231.2.10.2.6
OBJECT IDENTIFIER    

sniOemDpt 1.3.6.1.4.1.231.2.10.2.6.1
OBJECT IDENTIFIER    

sniOemMylex 1.3.6.1.4.1.231.2.10.2.6.2
OBJECT IDENTIFIER    

sniMlxDiskArray 1.3.6.1.4.1.231.2.10.2.6.2.1
OBJECT IDENTIFIER    

sniSecurity 1.3.6.1.4.1.231.2.10.2.7
OBJECT IDENTIFIER    

sniSmSecurity 1.3.6.1.4.1.231.2.10.2.7.1
OBJECT IDENTIFIER    

sniServerView 1.3.6.1.4.1.231.2.10.2.8
OBJECT IDENTIFIER    

sniTrapMib 1.3.6.1.4.1.231.2.10.5
OBJECT IDENTIFIER    

agentInfo 1.3.6.1.4.1.231.2.10.2.2.5.1
OBJECT IDENTIFIER    

environment 1.3.6.1.4.1.231.2.10.2.2.5.2
OBJECT IDENTIFIER    

errorHandling 1.3.6.1.4.1.231.2.10.2.2.5.3
OBJECT IDENTIFIER    

systemBoard 1.3.6.1.4.1.231.2.10.2.2.5.4
OBJECT IDENTIFIER    

pagerSetup 1.3.6.1.4.1.231.2.10.2.2.5.5
OBJECT IDENTIFIER    

standardBiosSetup 1.3.6.1.4.1.231.2.10.2.2.5.7
OBJECT IDENTIFIER    

serverBiosSetup 1.3.6.1.4.1.231.2.10.2.2.5.8
OBJECT IDENTIFIER    

powerOnOff 1.3.6.1.4.1.231.2.10.2.2.5.9
OBJECT IDENTIFIER    

systemControlInfo 1.3.6.1.4.1.231.2.10.2.2.5.10
OBJECT IDENTIFIER    

powerSupply 1.3.6.1.4.1.231.2.10.2.2.5.11
OBJECT IDENTIFIER    

uninterruptablePowerSupply 1.3.6.1.4.1.231.2.10.2.2.5.12
OBJECT IDENTIFIER    

diagnostics 1.3.6.1.4.1.231.2.10.2.2.5.13
OBJECT IDENTIFIER    

management 1.3.6.1.4.1.231.2.10.2.2.5.14
OBJECT IDENTIFIER    

trapInfo 1.3.6.1.4.1.231.2.10.2.2.5.20
OBJECT IDENTIFIER    

agentId 1.3.6.1.4.1.231.2.10.2.2.5.1.1
Agent identification string
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

agentCompany 1.3.6.1.4.1.231.2.10.2.2.5.1.2
Agent's company name
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

agentVersionString 1.3.6.1.4.1.231.2.10.2.2.5.1.3
Agent's version string . (i.e. 1.05)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

agentBuild 1.3.6.1.4.1.231.2.10.2.2.5.1.4
Compilation time and date of agent program
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

agentVersionMajor 1.3.6.1.4.1.231.2.10.2.2.5.1.5
Agent's major version (numerical)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..9  

agentVersionMinor 1.3.6.1.4.1.231.2.10.2.2.5.1.6
Agent's minor version (numerical)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..99  

agentWriteAllowed 1.3.6.1.4.1.231.2.10.2.2.5.1.7
Defines whether writable objects can be written (except shutdown/power-off operations)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), write-not-allowed(2), write-allowed(3)  

agentShutdownAllowed 1.3.6.1.4.1.231.2.10.2.2.5.1.8
Defines whether shutdown/power-off objects can be written
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), shutdown-not-allowed(2), shutdown-allowed(3)  

temperatureSensorsTable 1.3.6.1.4.1.231.2.10.2.2.5.2.1
Table with data of all configured temperature sensors
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TemperatureSensors

temperatureSensors 1.3.6.1.4.1.231.2.10.2.2.5.2.1.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  TemperatureSensors  

tempCabinetId 1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.1
ID of the cabinet the temperature sensor is in (index, 0 based)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

tempSensorNumber 1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.2
Number of the sensor in this cabinet (index, 0 based)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

tempSensorStatus 1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.3
Status of this temperature sensor (OK, critical or shutdown temperature reached...). The cold and the damage temperature status levels are no longer supported (values 6, 8, 9, 10). Status not-available(99) can be a sensor of a cpu that is not installed. Status sensor-disabled(2) is currently not used.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), sensor-disabled(2), ok(3), sensor-fail(4), warning-temp-warm(5), warning-temp-cold(6), critical-temp-warm(7), critical-temp-cold(8), damage-temp-warm(9), damage-temp-cold(10), not-available(99)  

tempSensorPurpose 1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.4
Purpose of this temperature sensor (CPU, ambient, housing...). Purposes disable(2) and not-available(6) are no longer used.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), disable(2), cpu(3), ambient(4), housing(5), not-available(6), io-board(7), power-backplane(8)  

tempLowerWarningLevel 1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.5
Object made obsolete - no longer supported
Status: obsolete Access: read-only
OBJECT-TYPE    
  INTEGER 0..127  

tempUpperWarningLevel 1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.6
System sends a temperature warning when temperature rises ABOVE this level (degrees Celsius)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..127  

tempLowerCriticalLevel 1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.7
Object made obsolete - no longer supported
Status: obsolete Access: read-only
OBJECT-TYPE    
  INTEGER 0..127  

tempUpperCriticalLevel 1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.8
System becomes critical when temperature rises ABOVE this level (degrees Celsius). A system shutdown is performed if object tempCriticalReaction is set to shutdown-and-poweroff.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..127  

tempLowerDamageLevel 1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.9
Object made obsolete - no longer supported
Status: obsolete Access: read-only
OBJECT-TYPE    
  INTEGER 0..127  

tempUpperDamageLevel 1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.10
Object made obsolete - no longer supported
Status: obsolete Access: read-only
OBJECT-TYPE    
  INTEGER 0..127  

tempCurrentValue 1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.11
Current temperature value (degrees Celsius; -1: unknown temperature, problem with sensor, see tempSensorStatus)
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

tempCriticalReaction 1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.12
Reaction when a temperature gets critical (shutdown and power-off, continue...). The value unknown(1) cannot be set, a SET will deliver 'badValue'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), continue(2), shutdown-and-poweroff(3)  

tempSensorDesignation 1.3.6.1.4.1.231.2.10.2.2.5.2.1.1.13
String describing the purpose of each temperature sensor in a housing (e.g. CPU, ambient,...). This object will substitute the tempSensorPurpose object.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString  

fansTable 1.3.6.1.4.1.231.2.10.2.2.5.2.2
Table with data of all configured cooling devices (fans)
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Fans

fans 1.3.6.1.4.1.231.2.10.2.2.5.2.2.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Fans  

fanCabinetId 1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.1
ID of the cabinet the cooling device (fan) is in (index, 0 based)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

fanNumber 1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.2
Number of the fan in this cabinet (index, 0 based)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

fanStatus 1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.3
Status of this fan (OK, failed...). Status disabled(2) is no longer used. Status prefailure-predicted(5) means the fan will fail in near future. Status redundant-fan-failed(6) means a redundant fan has failed, the system is not yet critical. Status not-manageable(7) is a fan that is available but has no management facilities. Status not-present(8) can be a hot-plug fan that is currently removed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), disabled(2), ok(3), fail(4), prefailure-predicted(5), redundant-fan-failed(6), not-manageable(7), not-present(8)  

fanPurpose 1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.4
Purpose of this fan (housing, component, CPU on-chip, power supply...). Purpose disabled(2) is currently not used.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), disable(2), cpu-onchip(3), component(4), housing(5), power-supply(6), not-available(7)  

fanPositionX 1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.5
Fax X position - obsolete; for fan indentifying use fanIdentification object
Status: obsolete Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

fanPositionY 1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.6
Fax Y position - obsolete; for fan indentifying use fanIdentification object
Status: obsolete Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

fanPositionZ 1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.7
Fax Z position - obsolete; for fan indentifying use fanIdentification object
Status: obsolete Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

fanCurrentSpeed 1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.8
Current speed of the fan (in revolutions per minute, -1 = unknown)
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

fanNominalMaximumSpeed 1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.9
Nominal speed of the fan (in revolutions per minute) on maximum power; the speed is measured the first time the agent is installed and than compared daily to the current speed on maximum power to detect a fan prefailure (-1 = unknown).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

fanCurrentMaximumSpeed 1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.10
Current speed of the fan (in revolutions per minute) on maximum power (-1 = unknown).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

fanMaximumSpeedCriticalLevel 1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.11
Obsolete - no longer supported.
Status: obsolete Access: read-only
OBJECT-TYPE    
  INTEGER  

fanMinimumSpeed 1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.12
Obsolete - no longer supported.
Status: obsolete Access: read-only
OBJECT-TYPE    
  INTEGER  

fanFailReaction 1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.14
Reaction when a fan has failed (shutdown and power-off, continue...). The value unknown(1) cannot be set, a SET will deliver 'badValue'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), continue(2), shutdown-and-poweroff(3)  

fanFailShutdownDelay 1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.15
Delay time (in seconds) when shutdown should commit on fan fail (if shutdown-and-off is configured, 0 = immediately, -1 = unknown). The value unknown(-1) cannot be set, a SET will deliver 'badValue'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..300  

fanDesignation 1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.16
String describing the purpose of each fan in a housing (e.g. CPU, Power Supply,...). This object will substitute the fanPurpose object.
Status: optional Access: read-write
OBJECT-TYPE    
  DisplayString  

fanIdentification 1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.17
String identifying each fan in a housing (e.g. CPU0, CPU1, PS0...)
Status: optional Access: read-write
OBJECT-TYPE    
  DisplayString  

fanDailyTestTime 1.3.6.1.4.1.231.2.10.2.2.5.2.3
Daily time when to automatically test fan speeds (in minutes since midnight; -1 = unknown, automatic fan test not supported). The value unknown(-1) cannot be set, a SET will deliver 'badValue'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1439  

fanStartTest 1.3.6.1.4.1.231.2.10.2.2.5.2.4
Start test of all fans to get the speed at maximum power (this test is normally started automatically once a day). Reading this object just returns the value 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER start-test(1)  

eventLogTable 1.3.6.1.4.1.231.2.10.2.2.5.3.1
Table with event log entries (can also contain critical errors when an ErrorLog for critical errors is not available)
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    EventLog

eventLog 1.3.6.1.4.1.231.2.10.2.2.5.3.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  EventLog  

eventLogEntryNumber 1.3.6.1.4.1.231.2.10.2.2.5.3.1.1.1
Entry number in eventLogTable (index, 0 based)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

eventLogMessageData 1.3.6.1.4.1.231.2.10.2.2.5.3.1.1.2
Non-critical message log entry as described above
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

eventLogMaxEntries 1.3.6.1.4.1.231.2.10.2.2.5.3.2
Number of EventLog entries (can be used to directly get all table entries with one varbind list)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

errorLogTable 1.3.6.1.4.1.231.2.10.2.2.5.3.3
Table with major and critial error log entries (can be missing on some hardware platforms)
Status: optional Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ErrorLog

errorLog 1.3.6.1.4.1.231.2.10.2.2.5.3.3.1
Tok_String
Status: optional Access: not-accessible
OBJECT-TYPE    
  ErrorLog  

errorLogEntryNumber 1.3.6.1.4.1.231.2.10.2.2.5.3.3.1.1
Entry number in critical errorLogTable (index, 0 based)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

errorLogMessageData 1.3.6.1.4.1.231.2.10.2.2.5.3.3.1.2
Major/critical message log entry as described above
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

errorLogMaxEntries 1.3.6.1.4.1.231.2.10.2.2.5.3.4
Number of ErrorLog entries (can be used to directly get all table entries with one varbind list)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

hardwareWatchdogStatus 1.3.6.1.4.1.231.2.10.2.2.5.3.5
Status of the hardware watchdog (periodically restarted by the server management BIOS). The hardware watchdog is only supported on SMI based management hardware, not for micro controller hardware.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), disable(2), enable(3), not-available(4)  

hardwareWatchdogTime 1.3.6.1.4.1.231.2.10.2.2.5.3.6
Timeout time of the hardware watchdog (in seconds, -1 = unknown)
Status: obsolete Access: read-only
OBJECT-TYPE    
  INTEGER 1..99  

hardwareWatchdogEnable 1.3.6.1.4.1.231.2.10.2.2.5.3.7
Enable/disable the hardware watchdog. The value unknown(1) cannot be set, a SET will deliver 'badValue'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), disable(2), enable(3)  

softwareWatchdogStatus 1.3.6.1.4.1.231.2.10.2.2.5.3.8
Status of the software watchdog (periodically restarted by the server management agent)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), disable(2), enable(3), not-available(4)  

softwareWatchdogTime 1.3.6.1.4.1.231.2.10.2.2.5.3.9
Timeout time of the software watchdog (in minutes, -1 = unknown). The value unknown(-1) cannot be set, a SET will deliver 'badValue'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..120  

softwareWatchdogEnable 1.3.6.1.4.1.231.2.10.2.2.5.3.10
Enable/disable the software watchdog. The value unknown(-1) cannot be set, a SET will deliver 'badValue'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), disable(2), enable(3)  

softwareWatchdogAction 1.3.6.1.4.1.231.2.10.2.2.5.3.11
Behavior when the software watchdog timeout occurs (reboot, continue...). This value is only used if the watchdog is enabled. If set to continue and the watchdog has timeout, it will only be logged and no reset happens. The value unknown(1) cannot be set, a SET will deliver 'badValue'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), continue(2), reboot(3), nmi(4), power-cycle(5)  

bootWatchdogStatus 1.3.6.1.4.1.231.2.10.2.2.5.3.12
Status of the boot watchdog (started at system boot, reset by the server management agent). If the SC agent is not started within the specified time, the management controller assumes the system did not boot correctly and executes system reboot.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), disable(2), enable(3), not-available(4)  

bootWatchdogTime 1.3.6.1.4.1.231.2.10.2.2.5.3.13
Timeout time of the boot watchdog (in minutes, -1 = unknown). The value unknown(-1) cannot be set, a SET will deliver 'badValue'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..120  

bootWatchdogEnable 1.3.6.1.4.1.231.2.10.2.2.5.3.14
Enable/disable the boot watchdog. The value unknown(-1) cannot be set, a SET will deliver 'badValue'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), disable(2), enable(3)  

bootWatchdogAction 1.3.6.1.4.1.231.2.10.2.2.5.3.15
Behavior when the boot watchdog timeout occurs (reboot, continue...). This value is only used if the watchdog is enabled. If set to continue and the watchdog has timeout, it will only be logged and no reset happens. The value unknown(1) cannot be set, a SET will deliver 'badValue'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), continue(2), reboot(3), nmi(4), power-cycle(5)  

cpuTable 1.3.6.1.4.1.231.2.10.2.2.5.4.1
Table with CPU information
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cpu

cpu 1.3.6.1.4.1.231.2.10.2.2.5.4.1.1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Cpu  

cpuTableIndex 3.1
Number of the CPU in the CpuTable (index, 0 based)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..31  

cpuType 3.2
Type of the CPU (486, Pentium, R2000...)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), i386(3), i486(4), pentium(5), pentium-pro(6), unknown-mips(101), r2000(102), r3000(103), r4000(104), r5000(105), r10000(110), r12000(112)  

cpuFrequency 3.3
Frequency of the CPU (in MHz, -1 = unknown)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpuStep 3.4
Step (version) of the CPU (-1 = unknown)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpuStatus 3.6
Status of a CPU: unknown(1) : CPU status could not be evaluated disabled(2) : CPU was manually disabled in BIOS setup ok(3) : CPU is available and operating properly not-present(4) : CPU is not available, empty socket error(5) : CPU has encountered errors but is still in use fail(6) : CPU has failed and is disabled missing-termination(7): CPU socket needs a terminator module when not populated but the terminator is missing prefailure-warning(8) : CPU has too many correctable errors within a certain time period
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), disabled(2), ok(3), not-present(4), error(5), fail(6), missing-termination(7), prefailure-warning(8)  

cpuModel 3.7
Model of the CPU (-1 = unknown)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpuName 3.8
Name of the CPU (e.g. 'Pentium', 'Pentium Pro' ...) as text string
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cpuSocketDesignation 3.9
String containing the socket designation of a CPU. This is the same text that is written on the system board.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cpuManufacturer 3.10
String containing the CPU manufacturer.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cpuNrLogicalsPerPhysical 3.11
Number of logical CPUs within one physical CPU (for hyper-threading and multi-core CPUs). This is the sum of all cores and all logical CPUs of a hyper-threading CPU.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpuCacheL1Size 3.12
Level 1 cache size (kByte) of a physical CPU (0 if unknown or not available).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpuCacheL2Size 3.13
Level 2 cache size (kByte) of a physical CPU (0 if unknown or not available).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpuCacheL3Size 3.14
Level 3 cache size (kByte) of a physical CPU (0 if unknown or not available).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpuNrCoresPerPhysical 3.15
Number of cores within one physical CPU (for multi-core CPUs).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

secondLevelCacheSize 1.3.6.1.4.1.231.2.10.2.2.5.4.2
Size of the second level cache (in kBytes, 0 if not available or disabled, -1 = unknown). Object will be made obsolete in next releases; use cpuCacheL2Size instead!
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

secondLevelCacheWritePolicy 1.3.6.1.4.1.231.2.10.2.2.5.4.3
Write policy of the second level cache (write-back, write-through). Object will be made obsolete in next releases (no longer required).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), write-back(2), write-through(3)  

physicalMemorySize 1.3.6.1.4.1.231.2.10.2.2.5.4.4
Size of the whole physical memory on the system board (in MBytes, -1 = unknown)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

baseMemorySize 1.3.6.1.4.1.231.2.10.2.2.5.4.5
Size of the base memory (below 1 MB) on the system board (in kBytes, -1 = unknown)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

extendedMemorySize 1.3.6.1.4.1.231.2.10.2.2.5.4.6
Size of the extended memory (above 1 MB) on the system board (in MBytes, -1 = unknown)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

utilizationMethod 1.3.6.1.4.1.231.2.10.2.2.5.4.7
Method to get utilization values: take-snapshot-now: get all values and store them to have all values at one certain time (set this object each time you want to get new values) get-current-values (default): get the values directly without buffering. The value unknown(1) cannot be set, a SET will deliver 'badValue'.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), take-snapshot-now(2), get-current-values(3)  

utilizationPciLoad 1.3.6.1.4.1.231.2.10.2.2.5.4.8
Load on the PCI bus (in percent; -1 if unknown); do no longer use this object for new implementations; object replaced by pciUtilizationTable.
Status: optional Access: read-only
OBJECT-TYPE    
  Gauge  

utilizationEisaLoad 1.3.6.1.4.1.231.2.10.2.2.5.4.9
Load on the EISA bus (in percent; -1 if unknown)
Status: optional Access: read-only
OBJECT-TYPE    
  Gauge  

memoryModulesTable 1.3.6.1.4.1.231.2.10.2.2.5.4.10
Table with memory module descripitions
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MemoryModules

memoryModules 1.3.6.1.4.1.231.2.10.2.2.5.4.10.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MemoryModules  

memModuleNumber 1.3.6.1.4.1.231.2.10.2.2.5.4.10.1.1
Module number (index, 0 based)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

memModuleBank 1.3.6.1.4.1.231.2.10.2.2.5.4.10.1.2
Bank number the module belongs to (-1 = unknown).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

memModuleStatus 1.3.6.1.4.1.231.2.10.2.2.5.4.10.1.3
Status of the memory module socket (OK, fail, disabled...). unknown(1) : module status could not be evaluated error(2) : module has encountered errors but is still in use ok(3) : module is available and operating properly not-available(4) : empty socket, module is not available fail(5) : module has failed and is disabled prefailure-warning(6) : module has too many correctable errors within a certain time period hot-space(7) : module is a hot-spare (standby) module, which can be used as a run-time-replacement for failed modules mirror(8) : module is part of a mirror disabled(9) : module was manually disabled in BIOS setup raid(10) : module is part of a memory module RAID system
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), error(2), ok(3), not-available(4), fail(5), prefailure-warning(6), hot-spare(7), mirror(8), disabled(9), raid(10)  

memModuleErrors 1.3.6.1.4.1.231.2.10.2.2.5.4.10.1.4
Number of (parity) errors in this module since last error count reset (-1 = unknown)
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

memModuleStartAddress 1.3.6.1.4.1.231.2.10.2.2.5.4.10.1.5
Start address of the bank this memory belongs to (-1 = unknown). This object is obsolete when the main memory size exceeds 2 GByte. Use new object memModuleStartAddressMB instead.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

memModuleSize 1.3.6.1.4.1.231.2.10.2.2.5.4.10.1.6
Size of this memory module (in bytes, -1 = unknown). This object is obsolete when the module's size exceeds 2 GByte. Use new object memModuleSizeMB instead.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

memModuleType 1.3.6.1.4.1.231.2.10.2.2.5.4.10.1.7
Type of memory module (Parity, NoParity, ECD, EDO...). Will be made obsolete in next agent releases!!! Use memModuleType2 for newer implementations!
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), other(2), no-parity(3), parity(4), parity-or-edc(5), edc(6), edo(7), synchrone-edo(8)  

memModuleType2 1.3.6.1.4.1.231.2.10.2.2.5.4.10.1.8
Information about the type of a memory module (Parity, ECC, EDO, SIMM, DIMM...). The type is a combination of one or more bits. Bit field: Bit 0 - Other Bit 1 - Unknown Bit 2 - Standard Bit 3 - Fast page mode Bit 4 - EDO Bit 5 - Parity Bit 6 - ECC Bit 7 - SIMM Bit 8 - DIMM Bit 9 - RIMM Unused bits are set to zero.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

memModuleSocketDesignation 1.3.6.1.4.1.231.2.10.2.2.5.4.10.1.9
String containing the socket designation of a memory module. This is the same text that is written on the system board.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

memModuleCorrectableErrors 1.3.6.1.4.1.231.2.10.2.2.5.4.10.1.10
Number of correctable errors in this module since last error count reset (-1 = unknown)
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

memModuleApproved 1.3.6.1.4.1.231.2.10.2.2.5.4.10.1.11
Information whether the memory module has been approved by the system vendor. unknown(1) is given when a module is not available or module cannot be accessed; no(2) when no approval information is found; yes(3) when a valid approval information is found in the module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), no(2), yes(3)  

memModuleStartAddressMB 1.3.6.1.4.1.231.2.10.2.2.5.4.10.1.12
Start address (in MBytes) of the bank this memory belongs to (-1 = unknown). This object makes the object memModuleStartAddress obsolete (4 GByte limit).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

memModuleSizeMB 1.3.6.1.4.1.231.2.10.2.2.5.4.10.1.13
Size (in MBytes) of this memory module (-1 = unknown). This object makes the object memModuleSize obsolete (4 GByte limit).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

memoryErrorCounterReset 1.3.6.1.4.1.231.2.10.2.2.5.4.11
Reset the memory module error counters (and set a new start time), reading this object just returns the value 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER reset(1)  

memoryErrorCounterStartTime 1.3.6.1.4.1.231.2.10.2.2.5.4.12
Time when memory module error counters were started (seconds since 1/1/1970, -1 = unknown)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

pciUtilizationTable 1.3.6.1.4.1.231.2.10.2.2.5.4.13
Table with PCI bus utilization data; independent of utilizationMethod object, update method for this table is always get-current-values. The number of entries in this table can be read from MIB object sniScNumberPciBusses.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PciUtilization

pciUtilization 1.3.6.1.4.1.231.2.10.2.2.5.4.13.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PciUtilization  

pciUtilBusNumber 1.3.6.1.4.1.231.2.10.2.2.5.4.13.1.1
PCI bus number (index, 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

pciUtilBusLoad 1.3.6.1.4.1.231.2.10.2.2.5.4.13.1.2
PCI bus load (in percent, 0xffffffff if unknown)
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

pciUtilBusTransferRate 1.3.6.1.4.1.231.2.10.2.2.5.4.13.1.3
PCI bus data transfer rate (in MBytes/second, 0xffffffff if unknown)
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

pciUtilBusEfficiency 1.3.6.1.4.1.231.2.10.2.2.5.4.13.1.4
PCI bus efficiency, ratio of data transfer rate through bus load (in percent); avarage value over all devices on this PCI bus; optimum value is 100 percent (0xffffffff if unknown).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

sniScBiosVersionString 1.3.6.1.4.1.231.2.10.2.2.5.4.14
String containing complete BIOS version, e.g. V4.05 R1.03.887
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sniScNumberCpuSockets 1.3.6.1.4.1.231.2.10.2.2.5.4.15
Number of CPU sockets available on the system board. This is not the number of currently installed CPUs! This object also describes the number of entries in the 'cpuTable' (-1 = unknown).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sniScNumberMemoryModules 1.3.6.1.4.1.231.2.10.2.2.5.4.16
Number of memory module sockets available on the system board (or memory extension board). This is not the number of currently installed memory modules! This object also describes the number of entries in the 'memoryModulesTable' (-1 = unknown).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sniScNumberPciBusses 1.3.6.1.4.1.231.2.10.2.2.5.4.17
Number of PCI busses available in the system (-1 = unknown).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

totalMemoryUsage 1.3.6.1.4.1.231.2.10.2.2.5.4.18
Total system memory usage (virtual and physical, in KBytes, -1 = unknown)
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

totalMemoryUsagePercent 1.3.6.1.4.1.231.2.10.2.2.5.4.19
Total system memory usage (virtual and physical, in percent, -1 = unknown)
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

physicalMemoryUsage 1.3.6.1.4.1.231.2.10.2.2.5.4.20
Physical system memory usage (in KBytes, -1 = unknown)
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

physicalMemoryUsagePercent 1.3.6.1.4.1.231.2.10.2.2.5.4.21
Physical system memory usage (in percent, -1 = unknown)
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

totalMemoryAvailable 1.3.6.1.4.1.231.2.10.2.2.5.4.22
Total system memory available (virtual and physical, in KBytes, -1 = unknown)
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

physicalMemoryAvailable 1.3.6.1.4.1.231.2.10.2.2.5.4.23
Physical system memory available (in KBytes, -1 = unknown)
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

physicalMemoryOsSize 1.3.6.1.4.1.231.2.10.2.2.5.4.24
Total size of the whole physical memory available to the operating system; this value is similar to 'physicalMemorySize', but may be less if the system has mirror or hot spare memory modules (in MBytes, -1 = unknown)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

pagerUserTable 1.3.6.1.4.1.231.2.10.2.2.5.5.1
Table with info of the users that should be paged
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PagerUser

pagerUser 1.3.6.1.4.1.231.2.10.2.2.5.5.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PagerUser  

pagerUserIndex 1.3.6.1.4.1.231.2.10.2.2.5.5.1.1.1
Index into pager user table (0 based)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

pagerType 1.3.6.1.4.1.231.2.10.2.2.5.5.1.1.2
Type of the installed pager (signal, numeric, alfa-numeric). The value unknown(1) and not-available(2) cannot be set, a SET will deliver 'badValue'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), not-available(2), signal(3), numeric(4), alfa-numeric(5)  

pagerUserName 1.3.6.1.4.1.231.2.10.2.2.5.5.1.1.3
Name of the pager user
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

pagerUserDescription 1.3.6.1.4.1.231.2.10.2.2.5.5.1.1.4
Description (function, optional) of the pager user
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

pagerActive 1.3.6.1.4.1.231.2.10.2.2.5.5.1.1.5
Describes whether this pager is active and should be called. The value unknown(1) cannot be set, a SET will deliver 'badValue'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), not-active(2), active(3)  

pagerNumber 1.3.6.1.4.1.231.2.10.2.2.5.5.1.1.6
User ID number of the user's pager
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

pagerServiceProviderNumber 1.3.6.1.4.1.231.2.10.2.2.5.5.1.1.7
Telephone dial number of the pager service provider (can also contain additional modem dial characters)
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

pagerActivityPrompt 1.3.6.1.4.1.231.2.10.2.2.5.5.1.1.8
Prompt string that should be received before pager number can be sent
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

pagerTimeModel 1.3.6.1.4.1.231.2.10.2.2.5.5.1.1.9
Encoded string containing a pager time model (when should which user be paged); this value is currently not used.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

pagerInitString 1.3.6.1.4.1.231.2.10.2.2.5.5.2
Init string that will be sent to the pager modem before the dialing begins
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

pagerServerNumber 1.3.6.1.4.1.231.2.10.2.2.5.5.3
Number of this server. It is sent together with the error number as a message to the user's pager (-1 = unknown). The value unknown(-1) cannot be set, a SET will deliver 'badValue'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

pagerComPort 1.3.6.1.4.1.231.2.10.2.2.5.5.4
COM port number (1...4) the pager modem is connected to. The value unknown(1) cannot be set, a SET will deliver 'badValue'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), com1(2), com2(3), com3(4), com4(5)  

pagerComPortBaudRate 1.3.6.1.4.1.231.2.10.2.2.5.5.5
Baud rate of the pager COM port. Following values are supported: 1200, 2400, 4800, 9600, 19200 (-1 = unknown). The value unknown(-1) cannot be set, a SET will deliver 'badValue'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

pagerComPortParity 1.3.6.1.4.1.231.2.10.2.2.5.5.6
Parity check configuration for the pager COM port. The value unknown(1) cannot be set, a SET will deliver 'badValue'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), even(2), odd(3), none(4), mark(5), space(6)  

pagerComPortNumBits 1.3.6.1.4.1.231.2.10.2.2.5.5.7
Number of bits per byte on the pager COM port (7, 8, -1 = unknown). The value unknown(-1) cannot be set, a SET will deliver 'badValue'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

pagerComPortFlowControl 1.3.6.1.4.1.231.2.10.2.2.5.5.8
Flow control method of the pager COM port (Hardware, XON/XOFF...). The value unknown(1) cannot be set, a SET will deliver 'badValue'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), none(2), hardware(3), xon-xoff(4)  

pagerModemName 1.3.6.1.4.1.231.2.10.2.2.5.5.9
Optional modem name or type; can be used just as info to be displayed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

stdSetupPasswordEnable 1.3.6.1.4.1.231.2.10.2.2.5.7.1
Tells whether a password is configured for the standard BIOS (read-only)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), disable(2), enable(3)  

stdSetupBootSource 1.3.6.1.4.1.231.2.10.2.2.5.7.2
Source medium to boot from: Normal system or diagnostic system standard(2): standard boot diag-system(4): boot from alternate diagnostic system The source the diagnostic system is booted from is selected in object 'srvSetupRebootFailAction'. The value unknown(1) cannot be set, a SET will deliver 'badValue'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), standard(2), diag-system(4)  

stdSetupPostErrorHalt 1.3.6.1.4.1.231.2.10.2.2.5.7.3
Describes what to do when a POST error has occured (halt on any error, no halt on any error...). The values unknown(1) and other(9) cannot be set, a SET will deliver 'badValue'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), halt-on-any-error(2), no-halt-on-any-error(3), other(9)  

stdSetupSerialInterface1 1.3.6.1.4.1.231.2.10.2.2.5.7.4
The COM port which the on-board serial interface 1 is mapped to (1...4). The value unknown(1) cannot be set, a SET will deliver 'badValue'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), disable(2), com-1(3), com-2(4), com-3(5), com-4(6), auto(9)  

stdSetupSerialInterface2 1.3.6.1.4.1.231.2.10.2.2.5.7.5
The COM port which the on-board serial interface 2 is mapped to (1...4). The value unknown(1) cannot be set, a SET will deliver 'badValue'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), disable(2), com-1(3), com-2(4), com-3(5), com-4(6), auto(9)  

stdSetupParallelInterface 1.3.6.1.4.1.231.2.10.2.2.5.7.6
The LPT port which the on-board parallel interface is mapped to (1...3). The value unknown(1) cannot be set, a SET will deliver 'badValue'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), disable(2), lpt-1(3), lpt-2(4), lpt-3(5), auto(9)  

stdSetupFloppyController 1.3.6.1.4.1.231.2.10.2.2.5.7.7
Describes whether the floppy controller is enabled. The value unknown(1) cannot be set, a SET will deliver 'badValue'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), disable(2), enable(3)  

stdSetupHarddiskController 1.3.6.1.4.1.231.2.10.2.2.5.7.8
Describes whether the IDE harddisk controller is enabled. The value unknown(1) cannot be set, a SET will deliver 'badValue'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), disable(2), primary(3), primary-and-secondary(4)  

stdSetupMouseController 1.3.6.1.4.1.231.2.10.2.2.5.7.9
Describes whether the mouse port controller is enabled. The value unknown(1) cannot be set, a SET will deliver 'badValue'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), disable(2), enable(3)  

srvSetupCabinetId 1.3.6.1.4.1.231.2.10.2.2.5.8.1
Cabinet ID number of this server (-1 = unknown). The value unknown(-1) cannot be set, a SET will deliver 'badValue'. Use this number as cabinetId for all tables containing a cabinet index. If unknown is delivered, 0 should be used as cabinet index.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

srvSetupServerRackSlot 1.3.6.1.4.1.231.2.10.2.2.5.8.2
Slot number (in a rack) this server is in (only for rack servers; -1 = unknown). The value unknown(-1) cannot be set, a SET will deliver 'badValue'. This object is currently not used.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER  

srvSetupServerGroupStart 1.3.6.1.4.1.231.2.10.2.2.5.8.3
deleted
Status: obsolete Access: read-write
OBJECT-TYPE    
  INTEGER  

srvSetupServerGroupEnd 1.3.6.1.4.1.231.2.10.2.2.5.8.4
deleted
Status: obsolete Access: read-write
OBJECT-TYPE    
  INTEGER  

srvSetupServerGroupMembers 1.3.6.1.4.1.231.2.10.2.2.5.8.5
deleted
Status: obsolete Access: read-write
OBJECT-TYPE    
  INTEGER  

srvSetupSeGroupStart 1.3.6.1.4.1.231.2.10.2.2.5.8.6
deleted
Status: obsolete Access: read-write
OBJECT-TYPE    
  INTEGER  

srvSetupSeGroupEnd 1.3.6.1.4.1.231.2.10.2.2.5.8.7
deleted
Status: obsolete Access: read-write
OBJECT-TYPE    
  INTEGER  

srvSetupSeGroupMembers 1.3.6.1.4.1.231.2.10.2.2.5.8.8
deleted
Status: obsolete Access: read-write
OBJECT-TYPE    
  INTEGER  

srvSetupRemoteOnEnable 1.3.6.1.4.1.231.2.10.2.2.5.8.9
Describes whether remote-on via RI modem line is enabled or not available. The value unknown(1) cannot be set, a SET will deliver 'badValue'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), disable(2), enable(3), not-available(4)  

srvSetupMaxRestartRetries 1.3.6.1.4.1.231.2.10.2.2.5.8.10
Maximum number of retries to reboot/restart the server when a shutdown (and power-off) had occured. After this number of retries the action defined in 'srvSetupRebootFailAction' will be executed (-1 = unknown, no retries). The value unknown(1) cannot be set, a SET will deliver 'badValue'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..7  

srvSetupRebootFailAction 1.3.6.1.4.1.231.2.10.2.2.5.8.11
Describes the action on a specified number of failed reboot retries (srvSetupMaxRestartRetries=0): unknown(1) - diagnostic system cannot be determined (cannot be SET) switch-off(2) - no diag system, final power-off ide-diag-disk(3) - boot diag system from IDE disk no-diag-system(4) - no diag system available remote-image-disk(5) - boot from remote image (over LAN) pxe(6) - boot from PXE (Preboot eXecution Environment) rsb-usb(7) - boot from RSB remote source (via USB interface) bmc-remote(8) - boot from BMC from remote storage This value is also the source to be booted from when object 'stdSetupBootSource' is set to 'diag-system'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), switch-off(2), ide-diag-disk(3), no-diag-system(4), remote-image-disk(5), pxe(6), rsb-usb(7), bmc-remote(8)  

srvSetupRebootFailPager 1.3.6.1.4.1.231.2.10.2.2.5.8.12
Describes whether the pager should be activated when reboot after error shutdown had occured. The value unknown(1) cannot be set, a SET will deliver 'badValue'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), pager-disabled(2), page-on-every-error-reboot(3)  

srvSetupSeGroupNumber 1.3.6.1.4.1.231.2.10.2.2.5.8.13
Group number for storage extension communication bus. Legal values are 0..9, -1 = unknown. The value unknown(-1) cannot be set, a SET will deliver 'badValue'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

srvSetupRestartRetriesDefault 1.3.6.1.4.1.231.2.10.2.2.5.8.14
Default number of retries to reboot/restart the server when a shutdown (and power-off) had occured. This value will be copied to object srvSetupMaxRestartRetries by the user to reset the counter to its original (default) value (-1 = unknown, no retries). The value unknown(1) cannot be set, a SET will deliver 'badValue'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..7  

onOffTimesTable 1.3.6.1.4.1.231.2.10.2.2.5.9.1
Table with system power on/off times; power-on will be performed by the real-time clock, power-off (with shutdown) by the operating system (system control service); table must be enabled before using
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OnOffTimes

onOffTimes 1.3.6.1.4.1.231.2.10.2.2.5.9.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  OnOffTimes  

onOffWeekday 1.3.6.1.4.1.231.2.10.2.2.5.9.1.1.1
Day of the week the times should act upon (index, 1 based); 1 = Sunday, 2 = Monday...
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..7  

onTime 1.3.6.1.4.1.231.2.10.2.2.5.9.1.1.2
Time the system should be switched on (by the real-time clock; in minutes since midnight; -1 = disabled, no on time). Only values -1 and 0..1439 are allowed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

offTime 1.3.6.1.4.1.231.2.10.2.2.5.9.1.1.3
Time the system should be switched off (by the operating system; in minutes since midnight; -1 = disabled, no off time). Only values -1 and 0..1439 are allowed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

shutdownDelayTime 1.3.6.1.4.1.231.2.10.2.2.5.9.2
The delay time (in minutes) the agent should wait before executing a shutdown (with doShutdown); 0 = default = shutdown immediately; -1 = unknown. The value unknown(-1) cannot be set, a SET will deliver 'badValue'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..120  

doShutdown 1.3.6.1.4.1.231.2.10.2.2.5.9.3
Execute a shutdown; argument tells what kind of shutdown: shutdown: wait for user to switch off or reboot shutdown-and-off: switch off after shutdown shutdown-and-reboot: reboot after shutdown abort-pending-shutdown: abort a delayed shutdown immediately (if not already initiated) Reading this object just returns the value 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER shutdown(1), shutdown-and-off(2), shutdown-and-reboot(3), abort-pending-shutdown(4)  

powerOnCounts 1.3.6.1.4.1.231.2.10.2.2.5.9.4
Tells how often the server was switched on in its life (-1 = unknown)
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

powerOnDurationHours 1.3.6.1.4.1.231.2.10.2.2.5.9.5
Tells how long the system was switched on in its life (in hours; -1 = unknown)
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

powerOffDurationHours 1.3.6.1.4.1.231.2.10.2.2.5.9.6
Tells how long the system was switched off in its life (in hours; -1 = unknown)
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

errorOffRestartDelay 1.3.6.1.4.1.231.2.10.2.2.5.9.7
Delay (in minutes) when the system should be automatically switched on again (by real-time clock) after an error power-off (-1 = no switch-on function). The value unknown(-1) cannot be set, a SET will deliver 'badValue'. On some platforms only the values 1, 2, 3, 5, 7, 10, 15 and 20 can be set. Values between these numbers will be rounded.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..30  

lastPostStatus 1.3.6.1.4.1.231.2.10.2.2.5.9.8
Describes whether the last (current) POST (power on self test) was errornous. Object is now obsolete - use object systemBootStatus instead!
Status: obsolete Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), ok(2), errors(3)  

lastPowerOffSource 1.3.6.1.4.1.231.2.10.2.2.5.9.9
Reason why the system was switched off last time
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), software-command(2), power-button(3), ac-fail(4), clock(5), fan-fail(6), temperature-critical(7), temperature-damage(8), power-supply-failure(9), watchdog(10), remote-off(11), hardware-fail(12), peripheral-bus-error(13), cpu-error(14), nmi(20), hardware-reset(23), warmstart(24), reset-button(25), ac-fail-reboot(26), keyboard(29), remote-manager(31), remote-manager-reset(32), power-cycle(33), power-limiting(35), mmb-continuous-operation(36), watchdog-power-cycle(37), viom-inventory-board(38), viom-init-boot(39), repeated-fan-fail(40), repeated-temperature-critical(41), firmware-restart(242), housing-opened(243), predecessor(244)  

lastPowerOnSource 1.3.6.1.4.1.231.2.10.2.2.5.9.10
Source the system was switched on from
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), software-command(2), power-button(3), ac-fail(4), clock(5), fan-fail(6), temperature-critical(7), temperature-damage(8), power-supply-failure(9), watchdog(10), remote-on(11), hardware-fail(12), peripheral-bus-error(13), cpu-error(14), nmi(20), hardware-reset(23), warmstart(24), reset-button(25), ac-fail-reboot(26), mgmt-processor-fail(27), pci-pme(28), keyboard(29), chipcard-reader(30), remote-manager(31), remote-manager-reset(32), power-cycle(33), viom-inventory-board(38), viom-init-boot(39), firmware-restart(242), housing-closed(243), predecessor(244)  

powerOnTime 1.3.6.1.4.1.231.2.10.2.2.5.9.11
Time and Date the system was booted (seconds since 1/1/1970; -1 = unknown)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

doPowerOnOff 1.3.6.1.4.1.231.2.10.2.2.5.9.12
Switch the server on or off; argument tells what kind of action: on: switch power on off: switch power off power-cycle: switch power off and switch power on again reset: perform a server reset nmi: perform a non-maskable interrupt (NMI, mainly for debugging purpose)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2), power-cycle(3), reset(4), nmi(5)  

systemBootResult 1.3.6.1.4.1.231.2.10.2.2.5.9.13
Result of the last server boot.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), os-boot-successful(2), diagnostic-boot-successful(3), no-boot-cpu(4), no-bootable-media(5), os-failed-to-load(6), diagnostic-boot-failed(7), hardware-failure(8)  

systemBootStatus 1.3.6.1.4.1.231.2.10.2.2.5.9.14
Status of the current boot process.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), off(2), no-boot-cpu(3), self-test(4), setup(5), os-boot(6), diagnostic-boot(7), os-running(8), diagnostic-running(9), os-shutdown(10), diagnostic-shutdown(11), reset(12)  

numberCabinetsConfigured 1.3.6.1.4.1.231.2.10.2.2.5.10.1
Number of configured cabinets (server and storage extensions, at least 1: the server itself)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

numberCabinetsDetected 1.3.6.1.4.1.231.2.10.2.2.5.10.2
Number of detected cabinets (server and storage extensions, at least 1: the server itself). This is also the number of entries in cabinetInfosTable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

cabinetInfosTable 1.3.6.1.4.1.231.2.10.2.2.5.10.3
Table with data of all configured cabinets
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CabinetInfos

cabinetInfos 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  CabinetInfos  

cabinetId 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.1
Cabinet ID number, index into the cabinet table
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cabinetLocation 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.2
The place where the cabinet is located (user can store any string here to identify the cabinet location)
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

cabinetIdentNumber 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.3
System ident number (serial number) - will be a number like 'XYZZ 12345678'. XYZZ is the cabinet identifier and is mandatory. It will be used to identify the cabinet model name (i.e. PCD-5S). 12345678 is the cabinet serial number and is optional. Cabinet identifier and serial number are separated by a blank character!
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

cabinetSystemName 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.4
System name string (i.e. PCD-5S, Primergy 150...)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cabinetNumberFans 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.5
The number of configured cooling devices (fans) in this cabinet (-1 = unknown)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cabinetNumberTempSensors 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.6
The number of configured temperature sensors in this cabinet (-1 = unknown)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cabinetNumberPowerSupplies 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.7
The number of available power supplies in this cabinet (-1 = unknown)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cabinetPowerSupplySlots 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.8
The number of power supply slots in this cabinet (is the maximum number of installable power supplies; 0 if no hot-plug slots available; -1 = unknown)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cabinetUpsUsed 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.9
Uninterruptable power supply for this cabinet available: 0: No UPS 1..n: Index in UPS table -1: unknown
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cabinetBoardSerialNumber 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.10
Serial number of the cabinet's system board
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cabinetBoardRevision 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.11
Revision (GS) of the cabinet's system board (-1 = unknown). Value obsolete, use sieScCabinetBoardRevisionString instead!
Status: obsolete Access: read-only
OBJECT-TYPE    
  INTEGER  

cabinetBoardId 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.12
Identifier string of the cabinet's system board
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cabinetManagementControllerType 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.13
Type of the cabinet's system management controller (i.e. SNI System Control Board)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cabinetControllerFirmwareMajor 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.14
Firmware version (major number) of the cabinet's system management controller (-1 = unknown). This object will be replaced by sieScCabinetControllerFirmware in future versions.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cabinetControllerFirmwareMinor 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.15
Firmware version (minor number) of the cabinet's system management controller (-1 = unknown). This object will be replaced by sieScCabinetControllerFirmware in future versions.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cabinetAttribute 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.16
Attribute of a cabinet (Primary/secondary server, storage extension...)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), standalone-server(2), primary-server(3), secondary-server(4), storage-extension(5)  

cabinetPowerOnStatus 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.17
Power-on state of the cabinet
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), off(2), on(3), disconnected(4)  

cabinetStatusSummary 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.18
Describes the status of a cabinet (OK, degraded, error...)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), degraded(2), error(3), fail(4)  

cabinetLastPoweroffSource 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.19
The source from which the cabinet was powered off last time
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), software-off(2), power-switch(3), power-fail(4), clock(5), fan-failure(6), critical-temperature(7), damage-temperature(8), power-supply-failure(9), watchdog(10), remote-off(11), hardware-fail(12), peripheral-bus-error(13), cpu-error(14), nmi(20), hardware-reset(23), warmstart(24), reset-button(25), ac-fail-reboot(26), keyboard(29), remote-manager(31), remote-manager-reset(32), power-limiting(35), mmb-continuous-operation(36), watchdog-power-cycle(37), viom-inventory-board(38), viom-init-boot(39), repeated-fan-fail(40), repeated-temperature-critical(41), firmware-restart(242), housing-opened(243), predecessor(244)  

cabinetActionAfterAcFail 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.20
Action on AC power resume after AC has failed. not-available(2) : function not available, behavior is hardware-defined. as-before(3) : server gets the same power state as before the AC fail. remain-off(4) : server remains off on power resume. switch-on(5) : server is always switched on on power resume. The value unknown(1) cannot be set, a SET will deliver 'badValue'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), not-available(2), as-before(3), remain-off(4), switch-on(5)  

cabinetBbuUsed 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.21
Battery buffering unit for this cabinet available. The value unknown(1) cannot be set, a SET will deliver 'badValue'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), false(2), true(3)  

cabinetSystemType 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.22
Value is obsolete. This value should no longer be used for cabinet identification. Use cabinetHousingType to identify the housing type and cabinetSystemName for the type of the cabinet!
Status: obsolete Access: read-only
OBJECT-TYPE    
  INTEGER  

cabinetStatusDetail 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.23
More detailed status information from this cabinet. The StatusDetail object is set to reflect the new status. ok: (status ok) no failures detected. selftestWarning: (status degraded) the SCB firmware issued a warning condition. selftestFailure: (status error) the SCB firmware detected a failure that prevents it from functioning. powerFailure: (status degraded) the AC input at the power supply or the AC input at the UPS failed. fanFailure: (status error) A fan in this cabinet failed. The system is going to shut down. temperatureFailure: (status error) A sensor in this cabinet detected an over temperature. The system is going to shut down. communicationFailure: (status error) The SCB in the CPU cabinet has lost communication with the SCB in this cabinet. The system is going to shut down. powerOff: (status degraded) The cabinet is switched off.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), selftestWarning(2), selftestFailure(4), powerFailure(8), fanFailure(16), temperatureFailure(32), communicationFailure(64), powerOff(128), temperatureWarning(256), bbuError(512)  

cabinetHousingType 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.24
Type string for cabinet housing type (i.e. 'P300' for all PRIMERGY 3xx housings); this object should be used to identify the cabinet instead of using object cabinetSystemType (i.e. for painting pictures in management applications)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cabinetFrontDoorStatus 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.25
Status of the cabinet's front door
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), open(2), closed(3)  

cabinetHousingOpenStatus 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.26
Status describing whether the housing is open or closed
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), open(2), closed(3)  

sieScCabinetNumberVoltages 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.27
Number of entries in power supply voltage table
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sieScCabinetControllerFirmware 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.28
The cabinet's system management controller firmware version (i.e. '1.1.4.88'). This object will replace the previous objects cabinetControllerFirmwareMinor and cabinetControllerFirmwareMajor.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sieScCabinetBoardRevisionString 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.29
Revision string (GS, WGS...) of the cabinet's system board. This object replaces the previous object cabinetBoardRevision.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sieScCabinetAdministrativeURL 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.30
Provides a URL that may be used by a front-end to start a web browser and connect it directly to the cabinet's administrative web server (e.g. https://10.0.0.2:443/foobar.html).
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sieScRemcsId 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.31
REMCS system identification string (binary data): Format of Fujitsu REMCS ID (40byte) Format = TTMMMMMMMMMMMMmmmmmmmmmmmmCCnnnnnnnnnnnn TT : 2byte : Type ID for Company Name MM...M : 12byte : Model Name mm...m : 12byte : Device Name CC : 2byte : Checksum nn...n : 12byte : Serial number
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

statusSummary 1.3.6.1.4.1.231.2.10.2.2.5.10.4
Value is obsolete
Status: obsolete Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), degraded(2), error(3), fail(4)  

serverType 1.3.6.1.4.1.231.2.10.2.2.5.10.5
Value is obsolete. This value should no longer be used for server identification. Use serverHousingType to identify the housing type and cabinetSystemName for the type of the server!
Status: obsolete Access: read-only
OBJECT-TYPE    
  INTEGER  

serverHousingType 1.3.6.1.4.1.231.2.10.2.2.5.10.6
Type string for cabinet housing type (i.e. 'P300' for all PRIMERGY 3xx housings); this object should be used to identify the cabinet instead of using object serverType (i.e. for painting pictures in management applications). This is the same value as from object cabinetHousingType for the server cabinet.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

serverUUID 1.3.6.1.4.1.231.2.10.2.2.5.10.7
Universal Unique ID (UUID) number - this is a world wide unique ID number of the server. Can be used for identifying a server. This UUID is formatted as specified in RFC 4122; shown in network byte order (big-endian). For little-endian format please use the SC2.MIB object sc2srvUUIDWireFormat! The UUID string format is like this: 157E465A-A4AC-D711-A847-DD85CECD12EC
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

powerSuppliesTable 1.3.6.1.4.1.231.2.10.2.2.5.11.1
Table with power supply groups in the cabinets
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PowerSupplies

powerSupplies 1.3.6.1.4.1.231.2.10.2.2.5.11.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PowerSupplies  

powerSupplyCabinetId 1.3.6.1.4.1.231.2.10.2.2.5.11.1.1.1
Cabinet ID, index into the power supply table (0 based)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

powerSupplyStatus 1.3.6.1.4.1.231.2.10.2.2.5.11.1.1.2
Status of the cabinet's power supply group; ok: all units OK, number >= minimum degraded: one or more units failed, number OK >= minimum critical: number OK < minimum.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), ok(2), degraded(3), critical(4)  

powerSupplyRedundancy 1.3.6.1.4.1.231.2.10.2.2.5.11.1.1.3
Number of available redundant power supply units (i.e. 2 units minimum, 3 available -> redundancy is 1, -1 = unknown)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..10  

powerSupplyUnitsTable 1.3.6.1.4.1.231.2.10.2.2.5.11.2
Table with info about the configured power supply units
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PowerSupplyUnits

powerSupplyUnits 1.3.6.1.4.1.231.2.10.2.2.5.11.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PowerSupplyUnits  

powerSupplyUnitCabinetId 1.3.6.1.4.1.231.2.10.2.2.5.11.2.1.1
Cabinet ID, index into the power supply unit table (0 based)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

powerSupplyUnitNumber 1.3.6.1.4.1.231.2.10.2.2.5.11.2.1.2
Power supply unit number, index into power supply unit table (0 based)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..9  

powerSupplyUnitStatus 1.3.6.1.4.1.231.2.10.2.2.5.11.2.1.3
Status of the power supply unit (OK, failed, not present...)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), not-present(2), ok(3), failed(4), ac-fail(5), dc-fail(6), critical-temperature(7), not-manageable(8), fan-failure-predicted(9), fan-failure(10), power-safe-mode(11), non-redundant-dc-fail(12), non-redundant-ac-fail(13)  

powerSupplyUnitDesignation 1.3.6.1.4.1.231.2.10.2.2.5.11.2.1.4
Power supply unit designation. This string specifies a name/designation for the power supply unit. The designation string may not be available on some platforms.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sniScVoltageTable 1.3.6.1.4.1.231.2.10.2.2.5.11.4
Table with power supply voltage information
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SniScVoltages

sniScVoltages 1.3.6.1.4.1.231.2.10.2.2.5.11.4.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SniScVoltages  

sniScVoltageCabinetNumber 1.3.6.1.4.1.231.2.10.2.2.5.11.4.1.1
Cabinet number, index into the power supply voltage table (0 based)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sniScVoltageNumber 1.3.6.1.4.1.231.2.10.2.2.5.11.4.1.2
Power supply voltage number, index into power supply voltage table (0 based)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sniScVoltageStatus 1.3.6.1.4.1.231.2.10.2.2.5.11.4.1.3
Status of the power supply voltage; 'not-available' maybe the voltage of an empty CPU socket; 'out-of-range' comes when the voltage is out of range; 'prefailure' is used for battery voltages and informs that the battery is predicted to fail in near future.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), not-available(2), ok(3), too-low(4), too-high(5), out-of-range(6), battery-prefailure(7)  

sniScVoltageDesignation 1.3.6.1.4.1.231.2.10.2.2.5.11.4.1.4
Power supply voltage designation. This string specifies the voltage by clear text (e.g. 5V, 12V, 3.3V...)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sniScVoltageMinimumValue 1.3.6.1.4.1.231.2.10.2.2.5.11.4.1.5
Power supply voltage minimum level (1/100th Volts; -1 = unknown)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sniScVoltageMaximumValue 1.3.6.1.4.1.231.2.10.2.2.5.11.4.1.6
Power supply voltage maximum level (1/100th Volts; -1 = unknown)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sniScVoltageCurrentValue 1.3.6.1.4.1.231.2.10.2.2.5.11.4.1.7
Power supply voltage current level, negative voltages are reported as negative values (1/100th Volts, e.g. 330 means 3.30 Volts; -177 (0xFFFFFF4F) means -1.77 Volts; 0xFFFFFFFF = unknown)
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

sniScVoltageNominalValue 1.3.6.1.4.1.231.2.10.2.2.5.11.4.1.8
Power supply voltage nominal level (1/100th Volts; -1 = unknown)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sniScVoltageOutputLoad 1.3.6.1.4.1.231.2.10.2.2.5.11.4.1.9
Power supply output load in percent of maximum load; 0xFFFFFFFF = unknown
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

upsCount 1.3.6.1.4.1.231.2.10.2.2.5.12.1
Number of uninterruptable power supplies (UPS) in this system (-1 = unknown)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

upsInfosTable 1.3.6.1.4.1.231.2.10.2.2.5.12.2
Table with uninterruptable power supplies used in this system. The index is the UPS number used in the system. One or more server or storage-extension objects can reference to a UPS entry in this table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    UpsInfos

upsInfos 1.3.6.1.4.1.231.2.10.2.2.5.12.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  UpsInfos  

upsNumber 1.3.6.1.4.1.231.2.10.2.2.5.12.2.1.1
Number of the UPS in this table (index, 1 based)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

upsDetected 1.3.6.1.4.1.231.2.10.2.2.5.12.2.1.2
Tells whether the UPS was detected
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), false(2), true(3)  

upsDischargeTime 1.3.6.1.4.1.231.2.10.2.2.5.12.2.1.3
Maximum time this UPS will be discharged, after that a shutdown will be performed (seconds; -1 = unknown)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

upsVendor 1.3.6.1.4.1.231.2.10.2.2.5.12.2.1.4
Vendor name of the UPS
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

upsType 1.3.6.1.4.1.231.2.10.2.2.5.12.2.1.5
Type of the UPS; can be used to identify an OEM UPS with an OEM agent
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

upsOemAgent 1.3.6.1.4.1.231.2.10.2.2.5.12.2.1.6
Object identifier of an OEM UPS MIB; no agent if empty OID
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

upsOemAgentAddress 1.3.6.1.4.1.231.2.10.2.2.5.12.2.1.7
IP address of an OEM UPS SNMP agent; no agent if empty
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

upsTimeOnBatterySeconds 1.3.6.1.4.1.231.2.10.2.2.5.12.2.1.8
Time (in seconds) the UPS is running on battery since power fail (will be cleared on power recovery)
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

spbbuStatus 1.3.6.1.4.1.231.2.10.2.2.5.12.3
Status of the service processor's backup battery (not present, OK, recharging)
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), not-present(2), ok(3), on-battery(4), recharging(5), failed(6), discharging(7)  

spbbuDischargeTime 1.3.6.1.4.1.231.2.10.2.2.5.12.4
Maximum time this backup battery will be discharged, after that a shutdown will be performed (seconds; -1 = unknown)
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

spbbuTimeOnBatterySeconds 1.3.6.1.4.1.231.2.10.2.2.5.12.5
Time (in seconds) the backup battery is running on battery since power fail (will be cleared on power recovery)
Status: optional Access: read-only
OBJECT-TYPE    
  Counter  

spbbuDoChargeCycle 1.3.6.1.4.1.231.2.10.2.2.5.12.6
Perform a discharge/charge cycle on the backup battery. Reading this object just returns the value 0.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER recharge(1)  

spbbuChargeStatus 1.3.6.1.4.1.231.2.10.2.2.5.12.7
Reads the current charge level of the rechargeable battery (in percent of the maximum capacity).
Status: optional Access: read-only
OBJECT-TYPE    
  Gauge  

interfaceParametersTable 1.3.6.1.4.1.231.2.10.2.2.5.14.1
Table with the interface parameters of all management channels, which are controlled by this server.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    InterfaceParameters

interfaceParameters 1.3.6.1.4.1.231.2.10.2.2.5.14.1.1
The interface parameters of the designated management channel interface.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  InterfaceParameters  

interfaceCabinetId 1.3.6.1.4.1.231.2.10.2.2.5.14.1.1.1
CabinetId of the cabinet where the management channel interface resides.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

interfaceNumber 1.3.6.1.4.1.231.2.10.2.2.5.14.1.1.2
Index number of the channel management interface (index, 0 based).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

interfaceType 1.3.6.1.4.1.231.2.10.2.2.5.14.1.1.3
The interface type of the interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), lan(2), dial-up(3)  

ipAddress 1.3.6.1.4.1.231.2.10.2.2.5.14.1.1.4
The IP v4 address of the interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

ipAdressNetMask 1.3.6.1.4.1.231.2.10.2.2.5.14.1.1.5
The IP v4 subnet mask of the interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

physicalAddress 1.3.6.1.4.1.231.2.10.2.2.5.14.1.1.6
The interface address of the physical layer of the interface (MAC address).
Status: mandatory Access: read-only
OBJECT-TYPE    
  PhysAddress  

phoneNumber 1.3.6.1.4.1.231.2.10.2.2.5.14.1.1.7
The telephone dial number of this interface. Only useful if the interfaceType is of type dial-up(3).
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

interfaceChannelType 1.3.6.1.4.1.231.2.10.2.2.5.14.1.1.8
The managegement channel type of the interface: primary: local operating system interface secondary: local management controller LAN interface management-blade: management blade interface (in a blade server chassis) secondary-remote: remote management controller (in an RSB concentrator environment) secondary-remote-backup: backup remote management controller baseboard-controller: baseboard management controller
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), primary(2), secondary(3), management-blade(4), secondary-remote(5), secondary-remote-backup(6), baseboard-controller(7)  

dhcpConfigured 1.3.6.1.4.1.231.2.10.2.2.5.14.1.1.9
Defines if the ip address should be requested by a dhcp service.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), configured(2), not-configured(3)  

controllerType 1.3.6.1.4.1.231.2.10.2.2.5.14.1.1.10
The type of the remote or baseboard management controller (for identification), like 'RSB', 'RSB S2', 'RSB S2 LP'... These names will not be changed if defined once.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

controllerModel 1.3.6.1.4.1.231.2.10.2.2.5.14.1.1.11
The model name of the remote management controller (for displaying), like 'Remote Service Board', 'RemoteView Service Board S2'... This name should not be used for identification, only for displaying (can be changed in different firmware versions)!
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

controllerFWVersion 1.3.6.1.4.1.231.2.10.2.2.5.14.1.1.12
The FW version of the remote or baseboard management controller as string;
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

serviceComponentsTable 1.3.6.1.4.1.231.2.10.2.2.5.14.2
Table with the components attached to the service processor
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ServiceComponents

serviceComponents 1.3.6.1.4.1.231.2.10.2.2.5.14.2.1
The components attached to the service processor
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ServiceComponents  

serviceComponentProcessorId 1.3.6.1.4.1.231.2.10.2.2.5.14.2.1.1
Id of the service processor this component is attached to (index, 0 based)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

serviceComponentId 1.3.6.1.4.1.231.2.10.2.2.5.14.2.1.2
Index number of the service component (index, 0 based)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

serviceComponentName 1.3.6.1.4.1.231.2.10.2.2.5.14.2.1.3
The name of the component in human readable form
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

serviceComponentType 1.3.6.1.4.1.231.2.10.2.2.5.14.2.1.4
The type of the componen we are dealing with.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), lan(2), dial-up(3), accumulator(4)  

serviceComponentStatus 1.3.6.1.4.1.231.2.10.2.2.5.14.2.1.5
Describes the status of the component managed by the service processor. Degraded means that some problems have occurred. Error that the component has reported an error that prevents the component form working. Failed means that the component is no longer reacting to the agents requests.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), degraded(2), error(3), failed(4)  

channelType 1.3.6.1.4.1.231.2.10.2.2.5.14.3
The managegement channel type of the currently used management channel.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), primary(2), secondary(3)  

sendTestTrap 1.3.6.1.4.1.231.2.10.2.2.5.13.1
Send a trap to the manager application(s) to test connection and trap configuration; trap cannot be disabled. Reading this object just returns the value 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER send-trap(1)  

trapServerName 1.3.6.1.4.1.231.2.10.2.2.5.20.1
Name of server the trap occured
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DisplayString  

trapTime 1.3.6.1.4.1.231.2.10.2.2.5.20.2
Time the trap occured (in seconds since 01/01/1970 00:00h)
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER  

trapCabinetNumber 1.3.6.1.4.1.231.2.10.2.2.5.20.3
Number of the cabinet where the trap was generated
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..999  

trapObjectNumber 1.3.6.1.4.1.231.2.10.2.2.5.20.4
Number of the object that generated the trap (fan, temperature sensor...)
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER  

trapString 1.3.6.1.4.1.231.2.10.2.2.5.20.5
Additional string to be displayed in the trap text
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DisplayString  

trapMinutesRemaining 1.3.6.1.4.1.231.2.10.2.2.5.20.6
The estimated remaining BBU/UPS capacity in minutes. In the current implementation this is the time remaining until the system will shut down.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER  

trapSecondsOnBattery 1.3.6.1.4.1.231.2.10.2.2.5.20.7
See scbUPSSecondsOnBattery/scbBBUSecondsOnBattery.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER  

trapConfigLowBattTime 1.3.6.1.4.1.231.2.10.2.2.5.20.8
The value of trapMinutesRemaining at which a shut down is initiated. In the current implementation this is always 0.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER  

trapNumValue 1.3.6.1.4.1.231.2.10.2.2.5.20.9
Additional numeric value to be displayed in the trap text
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER  

trapManagementInterfaceNumber 1.3.6.1.4.1.231.2.10.2.2.5.20.10
The number of the management channel interface.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER  

testTrap 600
Test trap to verify trap connection.
TRAP-TYPE    

fanError 601
The indicated fan failed.
TRAP-TYPE    

tempOk 602
The temperature of the indicated sensor has decreased to the normal level.
TRAP-TYPE    

tempWarn 603
The temperature of the indicated sensor has reached the warning level.
TRAP-TYPE    

tempCritical 604
The temperature of the indicated sensor is out of tolerance range. The system will shut down and power off if shutdown is enabled.
TRAP-TYPE    

trapOnBattery 606
The UPS is operating on battery power or the power supply is drawing current from the backup battery unit (BBU). This status is persistent and is resent at one minute intervals until the mains returns or the system is switched off.
TRAP-TYPE    

trapOnMains 607
The mains voltage returned after a power failure.
TRAP-TYPE    

selftestWarning 608
Currently the only possible warning is: SCB battery (nearly) empty.
TRAP-TYPE    

selftestError 609
The Server Management controller failed.
TRAP-TYPE    

svCommunicationFailure 610
Communication with the Server Management controller lost.
TRAP-TYPE    

scbUnconfiguredUPSDetected 611
A UPS has been detected, but no UPS is configured. This trap will be repeated every 60 minutes until the condition is removed.
TRAP-TYPE    

scbUPSNotdetected 612
A UPS is configured, but no UPS has been detected. This trap will be repeated every 60 minutes until the condition is removed.
TRAP-TYPE    

scbUnconfiguredBBUDetected 613
A BBU has been detected, but no BBU is configured. This trap will be repeated every 60 minutes until the condition is removed.
TRAP-TYPE    

scbBBUNotdetected 614
A BBU is configured, but no BBU has been detected. This trap will be repeated every 60 minutes until the condition is removed.
TRAP-TYPE    

notEnoughCabinets 615
One or more storage extensions missing.
TRAP-TYPE    

tooManyCabinets 616
The actual number of storage extensions is higher than the configured number.
TRAP-TYPE    

cabinetSwitchedOff 617
The cabinet has been switched off.
TRAP-TYPE    

cabinetSwitchedOn 618
The cabinet has been switched on.
TRAP-TYPE    

internalError 620
The agent has detected an internal error.
TRAP-TYPE    

serverShutdown 621
The server is being shut down.
TRAP-TYPE    

fanCriticalError 622
The indicated fan became critical.
TRAP-TYPE    

cabinetNotConfigured 623
The agent has detected a mismatch in the configuration of the server.
TRAP-TYPE    

powerSupplyRemoved 624
One hot-replace power supply was removed.
TRAP-TYPE    

powerSupplyAdded 625
One hot-replace power supply was added.
TRAP-TYPE    

powerSupplyFailed 626
One hot-replace power supply failed.
TRAP-TYPE    

powerSupplyOk 627
Power supply is working again.
TRAP-TYPE    

powerSupplyStatusCritical 628
Power supply status has become critical.
TRAP-TYPE    

fanOk 629
The indicated fan is OK again.
TRAP-TYPE    

tempSensorBroken 630
The indicated temperature sensor is broken.
TRAP-TYPE    

serverManagementDisabled 631
The server management BIOS is disabled.
TRAP-TYPE    

trapAcFail 632
Mains failed in the specified cabinet. This can only happen in storage extension cabinets without UPS or BBU. A server will not have time to send this event.
TRAP-TYPE    

trapDuplicateCabinetId 633
Two ore more cabinets (server or storage extension) have the same ID number. The system will not run properly.
TRAP-TYPE    

trapEventLog 634
An error message was written into the systemboard's event/error log. This could have happened when an error occured before the agent was running or any error without a specific event message. See server management event/error log for detailed error description.
TRAP-TYPE    

tempSensorOk 635
The indicated broken temperature sensor is OK again.
TRAP-TYPE    

svCommunicationEstablished 636
Communication with the Server Management controller established again.
TRAP-TYPE    

correctableMemErrorAddr 637
A correctable memory error at specified address was detected.
TRAP-TYPE    

uncorrectableMemErrorAddr 638
An uncorrectable memory error at specified address was detected.
TRAP-TYPE    

correctableMemErrorBank 639
A correctable memory error at specified bank was detected.
TRAP-TYPE    

uncorrectableMemErrorBank 640
An uncorrectable memory error at specified bank was detected.
TRAP-TYPE    

correctableMemErrorModule 641
A correctable memory error at specified module was detected.
TRAP-TYPE    

uncorrectableMemErrorModule 642
An uncorrectable memory error at specified module was detected.
TRAP-TYPE    

correctableMemError 643
A correctable memory error at unknown address was detected.
TRAP-TYPE    

uncorrectableMemError 644
An uncorrectable memory error at unknown address was detected.
TRAP-TYPE    

powerOffTimeReached 645
The power-off time is reached! System will shutdown in after delay.
TRAP-TYPE    

frontDoorStatusChanged 646
The front door status has changed.
TRAP-TYPE    

housingOpenStatusChanged 647
The housing open status has changed
TRAP-TYPE    

sniScRedundantFanFailed 648
The indicated redundant fan failed.
TRAP-TYPE    

sniScRedundantPowerSupplyFailed 649
One redundant hot-replace power supply failed.
TRAP-TYPE    

sniScVoltageOk 650
Power supply voltage is within normal range again.
TRAP-TYPE    

sniScVoltageTooLow 651
Power supply voltage is too low.
TRAP-TYPE    

sniScVoltageTooHigh 652
Power supply voltage is too high.
TRAP-TYPE    

sniScFanAdded 653
The indicated hot-plug fan was inserted.
TRAP-TYPE    

sniScFanRemoved 654
The indicated hot-plug fan was removed.
TRAP-TYPE    

sniScShutdownCancelled 655
This event will be sent if a pending server shutdown has been cancelled by the user.
TRAP-TYPE    

sniScCpuSpeedChanged 656
The CPU clock frequency has been reduced because of a temperature problem.
TRAP-TYPE    

sieScPowerOn 657
The server has been powered on.
TRAP-TYPE    

sieScNoBootCpu 658
The system boot failed because no valid boot CPU has been found.
TRAP-TYPE    

sieScPostError 659
This trap will be sent when the system boot fails, because the power on selftest (POST) has reported an error.
TRAP-TYPE    

sieScSetupEntered 660
This trap will be sent when the bios setup has been entered.
TRAP-TYPE    

sieScBootError 661
This trap will be sent when no bootable operating system can be found.
TRAP-TYPE    

sieScBootWatchdogExpired 662
This trap will be sent when the boot watchdog expires.
TRAP-TYPE    

sieScSoftwareWatchdogExpired 663
This trap will be sent when the software watchdog expires.
TRAP-TYPE    

sieScUserAuthenticationFailure 664
This trap will be sent when an user authentication failure is detected via PPP, FTP, HTTP or telnet fails.
TRAP-TYPE    

sieScDiagnosticBoot 665
This trap will be sent when a server is reset and diagnostic boot is enabled. The value in trapString specifies the primary channel i.e. the server name (from which the primary IP address may be derived).
TRAP-TYPE    

sieScBootRetryCountZero 666
This trap will be sent when a boot retry counter gets zero on power up
TRAP-TYPE    

sieScMessageLogFull 667
The System Event Log is full. No more messages can be logged. This trap will not occur on wrap-around log types.
TRAP-TYPE    

memErrorModulePrefailure 668
A memory module is predicted to fail (prefailure).
TRAP-TYPE    

memErrorModuleFailing 669
A memory module is failing.
TRAP-TYPE    

memErrorModuleReplaced 670
A memory module had failed and was replaced by a hot-spare module.
TRAP-TYPE    

sniScPowerSupplyRedundancyLost 671
Power supply redundancy no longer available.
TRAP-TYPE    

sieScMessageLogWarning 672
The warning threshold for the number of System Event Log entries has been exceeded.
TRAP-TYPE    

sieScCpuPrefailure 673
A CPU is predicted to fail (prefailure).
TRAP-TYPE    

sieScPowerFail 674
DC power failed in the specified cabinet. This is the result of the system's power-good sensor monitoring. The system may stop when this condition occurs.
TRAP-TYPE    

sieScBiosSelftestError 675
A critical error happend while BIOS selftest. This error needs to be acknowledged to clear the error condition.
TRAP-TYPE    

sieScBiosSelftestWatchdogExpired 676
This trap will be sent when the BIOS selftest watchdog expires. This watchdog expires when the BIOS selftest cannot be finished in a certain time period.
TRAP-TYPE    

sniScVoltageFailure 677
Power supply voltage is out of range.
TRAP-TYPE    

sniScBatteryVoltagePrefailure 678
Battery is predicted to fail.
TRAP-TYPE    

sieScSevereSystemError 679
The system was restarted after a severe problem. See server management message log (recovery log) for detailed information.
TRAP-TYPE