SLE-MPLS-TP-PRO-IF-MIB

File: SLE-MPLS-TP-PRO-IF-MIB.mib (5646 bytes)

Imported modules

DASAN-SMI MPLS-TE-STD-MIB SLE-TC-MIB
SNMPv2-SMI

Imported symbols

sleMgmt mplsTunnelIndex mplsTunnelInstance
mplsTunnelIngressLSRId mplsTunnelEgressLSRId SleControlStatusType
SleControlRequestResultType zeroDotZero TimeTicks
IpAddress Unsigned32 Gauge32
OBJECT-TYPE MODULE-IDENTITY OBJECT-IDENTITY

Defined Types

SleMplsTpProIfInfoEntry  
SEQUENCE    
  sleMplsTPProIfInfoIfIndex Unsigned32
  sleMplsTPProIfInfoIpAddr IpAddress

Defined Values

sleMplsTpNode 1.3.6.1.4.1.6296.101.16.13
Copyright (c) 2012 IETF Trust and the persons identified as the document authors. All rights reserved. This MIB module contains generic object definitions for MPLS Traffic Engineering in transport networks.
MODULE-IDENTITY    

sleMpls 1.3.6.1.4.1.6296.101.16
SLE MPLS.
Status: current Access: read-only
OBJECT-IDENTITY    

sleMplsTpProIf 1.3.6.1.4.1.6296.101.16.13.2
OBJECT IDENTIFIER    

sleMplsTpProIfInfoTable 1.3.6.1.4.1.6296.101.16.13.2.1
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SleMplsTpProIfInfoEntry

sleMplsTpProIfInfoEntry 1.3.6.1.4.1.6296.101.16.13.2.1.1
Status: current Access: not-accessible
OBJECT-TYPE    
  SleMplsTpProIfInfoEntry  

sleMplsTPProIfInfoIfIndex 1.3.6.1.4.1.6296.101.16.13.2.1.1.1
This object is used in accommodating the bigger size Global_Node_ID and/or ICC with lower size LSR identifier in order to index the mplsTunnelTable. The Local Identifier is configured between 1 and 16777215, as valid IP address range starts from 16777216(01.00.00.00). This range is chosen to identify the mplsTunnelTable's Ingress/Egress LSR-id is IP address or Local identifier, if the configured range is not IP address, administrator is expected to retrieve the complete information (Global_Node_ID or ICC) from mplsTunnelExtNodeConfigTable. This way, existing mplsTunnelTable is reused for bidirectional tunnel extensions for MPLS based transport networks. This Local Identifier allows the administrator to assign a unique identifier to map Global_Node_ID and/or ICC.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..65535  

sleMplsTPProIfInfoIpAddr 1.3.6.1.4.1.6296.101.16.13.2.1.1.2
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

sleMplsTpProIfControl 1.3.6.1.4.1.6296.101.16.13.2.2
OBJECT IDENTIFIER    

sleMplsTpProIfControlRequest 1.3.6.1.4.1.6296.101.16.13.2.2.1
This object holds the possible read-write columns that can be modified in the TunnelExtNodeConfigTable table. For each read-write column of TunnelExtNodeConfigTable table, a Set Operation control value is added in this object.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER setMplsTpProIfIpAddr(1), unSetMplsTpProIfIpAddr(2)  

sleMplsTpProIfControlStatus 1.3.6.1.4.1.6296.101.16.13.2.2.2
This object displays the status of the configuration done.
Status: current Access: read-only
OBJECT-TYPE    
  SleControlStatusType  

sleMplsTpProIfControlTimer 1.3.6.1.4.1.6296.101.16.13.2.2.3
This object is based on the SLE style where a timer is configured for every control table.
Status: current Access: read-write
OBJECT-TYPE    
  Gauge32  

sleMplsTpProIfControlTimestamp 1.3.6.1.4.1.6296.101.16.13.2.2.4
This object specifies the time at which the configuration is done.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

sleMplsTpProIfControlReqResult 1.3.6.1.4.1.6296.101.16.13.2.2.5
The standard result of the SET operation is stored here.
Status: current Access: read-only
OBJECT-TYPE    
  SleControlRequestResultType  

sleMplsTpProIfControlIfIndex 1.3.6.1.4.1.6296.101.16.13.2.2.6
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

sleMplsTpProIfControlIpAddr 1.3.6.1.4.1.6296.101.16.13.2.2.7
This object indicates the Global Operator Identifier.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress