SLE-MPLS-TP-LPS-MIB

File: SLE-MPLS-TP-LPS-MIB.mib (24708 bytes)

Imported modules

DASAN-SMI SLE-TC-MIB SNMPv2-SMI

Imported symbols

sleMgmt SleControlStatusType SleControlRequestResultType
TimeTicks Unsigned32 Gauge32
OBJECT-TYPE MODULE-IDENTITY OBJECT-IDENTITY

Defined Types

SleMplsTpLpsCfgInfoEntry  
SEQUENCE    
  sleMplsTpLpsCfgInfoGroupIndex Unsigned32
  sleMplsTpLpsCfgInfoGroupName OCTET STRING
  sleMplsTpLpsCfgInfoMode INTEGER
  sleMplsTpLpsCfgInfoProtectionScheme INTEGER
  sleMplsTpLpsCfgInfoRevertive INTEGER
  sleMplsTpLpsCfgInfoWtr Unsigned32
  sleMplsTpLpsCfgInfoContinualTxInterval Unsigned32
  sleMplsTpLpsCfgInfoRapidTxInterval Unsigned32
  sleMplsTpLpsCfgInfoSwitchOver INTEGER
  sleMplsTpLpsCfgInfoLockOut INTEGER
  sleMplsTpLpsCfgInfoHoldOffTimer Unsigned32
  sleMplsTpLpsCfgInfoActivePath INTEGER
  sleMplsTpLpsCfgInfoOperationState INTEGER
  sleMplsTpLpsCfgInfoEventStatus INTEGER

SleMplsTpLpsMeCfgInfoEntry  
SEQUENCE    
  sleMplsTpLpsMeCfgInfoMegIndex Unsigned32
  sleMplsTpLpsMeCfgInfoMeIndex Unsigned32
  sleMplsTpLpsMeCfgInfoMPId Unsigned32
  sleMplsTpLspMeCfgInfoGroupIndex Unsigned32
  sleMplsTpLpsMeCfgInfoState INTEGER

Defined Values

sleMplsTpLps 1.3.6.1.4.1.6296.101.16.18
This management information module supports the configuration and management of MplsTp TP linear protection groups.
MODULE-IDENTITY    

sleMpls 1.3.6.1.4.1.6296.101.16
SLE MplsTp.
Status: current Access: read-only
OBJECT-IDENTITY    

sleMplsTpLpsCfg 1.3.6.1.4.1.6296.101.16.18.1
OBJECT IDENTIFIER    

sleMplsTpLpsCfgInfoTable 1.3.6.1.4.1.6296.101.16.18.1.1
This table lists the sleMplsTp linear protection groups that have been configured on the system.
Status: current Access: read-only
OBJECT-TYPE    
  SEQUENCE OF  
    SleMplsTpLpsCfgInfoEntry

sleMplsTpLpsCfgInfoEntry 1.3.6.1.4.1.6296.101.16.18.1.1.1
A conceptual row in the sleMplsTpLpsCfgInfoTable.
Status: current Access: read-only
OBJECT-TYPE    
  SleMplsTpLpsCfgInfoEntry  

sleMplsTpLpsCfgInfoGroupIndex 1.3.6.1.4.1.6296.101.16.18.1.1.1.1
Index for the conceptual row identifying a protection group.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..65535  

sleMplsTpLpsCfgInfoGroupName 1.3.6.1.4.1.6296.101.16.18.1.1.1.2
Textual name represents the sleMplsTp tp protection group. Each Protection Group is identified by a unique protection group name.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1..128)  

sleMplsTpLpsCfgInfoMode 1.3.6.1.4.1.6296.101.16.18.1.1.1.3
The architectural mode of the Protection group. This can either be 1+1, 1:1, 1:n. 1+1 In the 1+1 protection scheme, a fully dedicated protection entity is allocated. Data traffic is copied and fed at the source to both the working and the protection entities. The traffic on the working and the protection entities is transmitted simultaneously to the sink of the protection domain, where selection between the working and protection entities is performed 1:1 In the 1:1 scheme, a protection path is allocated to protect against a defect, failure, or a degradation in a working path. In normal conditions, data traffic is transmitted over the working entity, while the protection entity functions in the idle state. If there is a defect on the working entity or a specific administrative request, traffic is switched to the protection entity. 1:n In case of 1:n linear protection, one protection entity is allocated to protect n working entities. The protection entity might not have sufficient resources to protect all the working entities that may be affected by fault conditions at a specific time. In this case, in order to guaranteed protection, the protection entity should support enough capacity and bandwidth to protect any of the n working entities.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER onePlusOne(1), oneColonOne(2), oneColonN(3)  

sleMplsTpLpsCfgInfoProtectionScheme 1.3.6.1.4.1.6296.101.16.18.1.1.1.4
The object represents the operational scheme of protection switching group. The protection scheme may either be unidirectional or bidirectional. bidirectional In bidirectional protection scheme, both the directions will be switched simultaneously even if the fault applies to only one direction of the path. unidirectional In unidirectional protection scheme protection switching will be performed independently for each direction of a bidirectional transport path This object may not be modified if the associated sleMplsTpLpsCfgRowStatus object is equal to active(1).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER bidirectional(1), unidirectional(2)  

sleMplsTpLpsCfgInfoRevertive 1.3.6.1.4.1.6296.101.16.18.1.1.1.5
This object represents the reversion mode of the Linear Protection Switching group. The reversion mode of protection mechanism may be either revertive or non-revertive. In non-revertive mode, after a service has been recovered, traffic will be forwarded on the recovery path revertive In revertive mode, after a service has been recovered, traffic will be redirected back onto the original working path.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER nonrevertive(1), revertive(2)  

sleMplsTpLpsCfgInfoWtr 1.3.6.1.4.1.6296.101.16.18.1.1.1.6
This object hold the Wait To Restore timer value in seconds. The WTR timer is used to delay reversion of PSC state to Normal state when recovering from a failure condition on the working path when the protection domain is configured for revertive behavior This object may not be modified if the associated sleMplsTpLpsCfgRowStatus object is equal to active(1).
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..720  

sleMplsTpLpsCfgInfoContinualTxInterval 1.3.6.1.4.1.6296.101.16.18.1.1.1.7
The Continual Tx Time in Seconds. Represents the time interval to send the continual LPS packet to the other end based on the current state.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 1..20  

sleMplsTpLpsCfgInfoRapidTxInterval 1.3.6.1.4.1.6296.101.16.18.1.1.1.8
The Rapid Tx interval in micro-Seconds. Represents the time interval to send the LPS packet to the other end, when there is a change in state of Linear Protection domain due to local input. The default value is 3.3 milli-seconds which is 3300 micro-seconds
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 1000..20000  

sleMplsTpLpsCfgInfoSwitchOver 1.3.6.1.4.1.6296.101.16.18.1.1.1.9
this object used for switch the traffic to the back up path.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(0), forced(1), manual(2)  

sleMplsTpLpsCfgInfoLockOut 1.3.6.1.4.1.6296.101.16.18.1.1.1.10
this is object is used for preventing the swith traffic by the protection path.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

sleMplsTpLpsCfgInfoHoldOffTimer 1.3.6.1.4.1.6296.101.16.18.1.1.1.11
this object used for show the hold off timer.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

sleMplsTpLpsCfgInfoActivePath 1.3.6.1.4.1.6296.101.16.18.1.1.1.12
This object say which path is Active .
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER primary(1), backup(2)  

sleMplsTpLpsCfgInfoOperationState 1.3.6.1.4.1.6296.101.16.18.1.1.1.13
this object says Operational Status of LPS. The LPS is between PE to PE.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER up(1), down(0)  

sleMplsTpLpsCfgInfoEventStatus 1.3.6.1.4.1.6296.101.16.18.1.1.1.14
This is object says EVENT Status of LPS protection .
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), protection(2), localForce(3), localManual(4), localSgfProtection(5), localSgfWorking(6), localWtr(7), localLock(8), localClrSfProtection(9), localClrSfWorking(10), localClrEvent(11), remoteLock(12), remoteForce(13), remoteManual(14), remoteSfProtect(15), remoteSfWork(16), remoteWtr(17), remoteNoReq(18), remoteNotRevert(19), noRequest(20), remoteSdWork(21), remoteSdProtection(22), remoteExesWork(23), remoteExesProtect(24), remoteRrReqWork(25), remoteRrReqProtec(26), remoteNoReqWork(27), remoteNoReqProtection(28), localSdProtection(29), localClearSdProtection(30), localSdWorking(31), localClearSdWorking(32), localExercise(33)  

sleMplsTpLpsCfgControl 1.3.6.1.4.1.6296.101.16.18.1.2
OBJECT IDENTIFIER    

sleMplsTpLpsCfgControlRequest 1.3.6.1.4.1.6296.101.16.18.1.2.1
the configuration commands, and user can configure functions via setting this entry as proper value.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER createSleMplsTpLpsCfgEntry(1), deleteSleMplsTpLpsCfgEntry(2), setSleMplsTpLpsCfgControProtectionScheme(3), unsetSleMplsTpLpsCfgControProtectionScheme(4), setSleMplsLpsTpCfgControlRevertive(5), setSleMplsLpsTpCfgControlWaitToRestoreset(6), unsetSleMplsTpLpsCfgControlWaitToRestoreset(7), setSleMplsLpsTpCfgControlContinualTxInterval(8), unsetSleMplsTpLpsCfgControlContinualTxInterval(9), setSleMplsLpsTpCfgControlRapidTxInterval(10), unsetSleMplsTpLpsCfgControlRapidTxInterval(11), setSleMplsLpsTpCfgControlSwitchover(12), unsetSleMplsTpLpsCfgControlSwitchover(13), setSleMplsTpLpsCfgControlLockOut(14), unsetSleMplsTpLpsTpCfgControlLockOut(15), setSleMplsTpLpsCfgControlHoldOffTimer(16), unSetSleMplsTpLpsCfgControlHoldOffTimer(17)  

sleMplsTpLpsCfgControlStatus 1.3.6.1.4.1.6296.101.16.18.1.2.2
status of user command. User have to check this value as .busy. or .idle. before do setRequest.
Status: current Access: read-only
OBJECT-TYPE    
  SleControlStatusType  

sleMplsTpLpsCfgControlTimer 1.3.6.1.4.1.6296.101.16.18.1.2.3
the wait-time until setRequest end. In case of short-time command, this value is 0
Status: current Access: read-write
OBJECT-TYPE    
  Gauge32  

sleMplsTpLpsCfgControlTimeStamp 1.3.6.1.4.1.6296.101.16.18.1.2.4
the time stamp of the last command. (don.t care)
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

sleMplsTpLpsCfgControlReqResult 1.3.6.1.4.1.6296.101.16.18.1.2.5
Result of the last command.
Status: current Access: read-only
OBJECT-TYPE    
  SleControlRequestResultType  

sleMplsTpLpsCfgControlGroupName 1.3.6.1.4.1.6296.101.16.18.1.2.6
Textual name represents the sleMplsTp tp protection group. Each Protection Group is identified by a unique protection group name.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1..32)  

sleMplsTpLpsCfgControlMode 1.3.6.1.4.1.6296.101.16.18.1.2.7
The architectural mode of the Protection group. This can either be 1+1, 1:1, 1:n. 1+1 In the 1+1 protection scheme, a fully dedicated protection entity is allocated. Data traffic is copied and fed at the source to both the working and the protection entities. The traffic on the working and the protection entities is transmitted simultaneously to the sink of the protection domain, where selection between the working and protection entities is performed 1:1 In the 1:1 scheme, a protection path is allocated to protect against a defect, failure, or a degradation in a working path. In normal conditions, data traffic is transmitted over the working entity, while the protection entity functions in the idle state. If there is a defect on the working entity or a specific administrative request, traffic is switched to the protection entity. 1:n In case of 1:n linear protection, one protection entity is allocated to protect n working entities. The protection entity might not have sufficient resources to protect all the working entities that may be affected by fault conditions at a specific time. In this case, in order to guaranteed protection, the protection entity should support enough capacity and bandwidth to protect any of the n working entities.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER onePlusOne(1), oneColonOne(2), oneColonN(3)  

sleMplsTpLpsCfgControlProtectionScheme 1.3.6.1.4.1.6296.101.16.18.1.2.8
The object represents the operational scheme of protection switching group. The protection scheme may either be unidirectional or bidirectional. bidirectional In bidirectional protection scheme, both the directions will be switched simultaneously even if the fault applies to only one direction of the path. unidirectional In unidirectional protection scheme protection switching will be performed independently for each direction of a bidirectional transport path This object may not be modified if the associated sleMplsTpLpsCfgControlRowStatus object is equal to active(1).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER bidirectional(1), unidirectional(2)  

sleMplsTpLpsCfgControlRevertive 1.3.6.1.4.1.6296.101.16.18.1.2.9
This object represents the reversion mode of the Linear Protection Switching group. The reversion mode of protection mechanism may be either revertive or non-revertive. nonrevertive In non-revertive mode, after a service has been recovered, traffic will be forwarded on the recovery path revertive In revertive mode, after a service has been recovered, traffic will be redirected back onto the original working path.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER nonrevertive(1), revertive(2)  

sleMplsTpLpsCfgControlWtr 1.3.6.1.4.1.6296.101.16.18.1.2.10
This object hold the Wait To Restore timer value in seconds. The WTR timer is used to delay reversion of PSC state to Normal state when recovering from a failure condition on the working path when the protection domain is configured for revertive behavior This object may not be modified if the associated sleMplsTpLpsCfgControlRowStatus object is equal to active(1).
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..720  

sleMplsTpLpsCfgControlContinualTxInterval 1.3.6.1.4.1.6296.101.16.18.1.2.11
The Continual Tx Time in Seconds. Represents the time interval to send the continual LPS packet to the other end based on the current state.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 1..20  

sleMplsTpLpsCfgControlRapidTxInterval 1.3.6.1.4.1.6296.101.16.18.1.2.12
The Rapid Tx interval in micro-Seconds. Represents the time interval to send the LPS packet to the other end, when there is a change in state of Linear Protection domain due to local input. The default value is 3.3 milli-seconds which is 3300 micro-seconds
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 1000  

sleMplsTpLpsCfgControlswitchOver 1.3.6.1.4.1.6296.101.16.18.1.2.13
this object used for switch the traffic to the back up path.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER force(1), manual(2)  

sleMplsTpLpsCfgControlLockOut 1.3.6.1.4.1.6296.101.16.18.1.2.14
this is object is used for preventing the swith traffic by the protection path.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(0)  

sleMplsTpLpsCfgControlHoldOffTimer 1.3.6.1.4.1.6296.101.16.18.1.2.15
This object is used to set the holdofftimer
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

sleMplsTpLpsMeCfg 1.3.6.1.4.1.6296.101.16.18.2
OBJECT IDENTIFIER    

sleMplsTpLpsMeCfgInfoTable 1.3.6.1.4.1.6296.101.16.18.2.1
This table lists Maintenance Association that have been configured in Protection groups.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SleMplsTpLpsMeCfgInfoEntry

sleMplsTpLpsMeCfgInfoEntry 1.3.6.1.4.1.6296.101.16.18.2.1.1
A conceptual row in the sleMplsTpLpsMeCfgInfoTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  SleMplsTpLpsMeCfgInfoEntry  

sleMplsTpLpsMeCfgInfoMegIndex 1.3.6.1.4.1.6296.101.16.18.2.1.1.1
Uniquely identifies a maintenance entity index within a MEG.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..65535  

sleMplsTpLpsMeCfgInfoMeIndex 1.3.6.1.4.1.6296.101.16.18.2.1.1.2
This object denotes the ME name, each Maintenance Entity has unique name within MEG.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..65535  

sleMplsTpLpsMeCfgInfoMPId 1.3.6.1.4.1.6296.101.16.18.2.1.1.3
Indicates the maintenance point index, used to create multiple MEPs in a node of single ME. The value of this object can be MEP index or MIP index. Managers should obtain new values for row creation in this table by reading mplsOamIdMeMpIndexNext.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 1..8191  

sleMplsTpLspMeCfgInfoGroupIndex 1.3.6.1.4.1.6296.101.16.18.2.1.1.4
Textual name represents the sleMplsTp tp protection group. Each Protection Group is identified by a unique protection group name.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..65535  

sleMplsTpLpsMeCfgInfoState 1.3.6.1.4.1.6296.101.16.18.2.1.1.5
This object represents the operational state of the ME as either primary or backup
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER primary(1), backup(2)  

sleMplsTpLpsMeCfgControl 1.3.6.1.4.1.6296.101.16.18.2.2
OBJECT IDENTIFIER    

sleMplsTpLpsMeCfgControlRequest 1.3.6.1.4.1.6296.101.16.18.2.2.1
the configuration commands, and user can configure functions via setting this entry as proper value.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER createSleMplsTpLpsMeConfigEntry(1), deleteSleMplsTpLpsMeConfigEntry(2)  

sleMplsTpLpsMeCfgControlStatus 1.3.6.1.4.1.6296.101.16.18.2.2.2
status of user command. User have to check this value as .busy. or .idle. before do setRequest.
Status: current Access: read-only
OBJECT-TYPE    
  SleControlStatusType  

sleMplsTpLpsMeCfgControlTimer 1.3.6.1.4.1.6296.101.16.18.2.2.3
the wait-time until setRequest end. In case of short-time command, this value is 0
Status: current Access: read-write
OBJECT-TYPE    
  Gauge32  

sleMplsTpLpsMeCfgControlTimeStamp 1.3.6.1.4.1.6296.101.16.18.2.2.4
the time stamp of the last command. (don.t care)
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

sleMplsTpLpsMeCfgControlReqResult 1.3.6.1.4.1.6296.101.16.18.2.2.5
Result of the last command.
Status: current Access: read-only
OBJECT-TYPE    
  SleControlRequestResultType  

sleMplsTpLpsMeCfgControlMegName 1.3.6.1.4.1.6296.101.16.18.2.2.6
Uniquely identifies a maintenance entity index within a MEG
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

sleMplsTpLpsMeCfgControlMeName 1.3.6.1.4.1.6296.101.16.18.2.2.7
This object denotes the ME name, each Maintenance Entity has unique name within MEG.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

sleMplsTpLpsMeCfgControlMpId 1.3.6.1.4.1.6296.101.16.18.2.2.8
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

sleMplsTpLpsMeCfgControlGroupName 1.3.6.1.4.1.6296.101.16.18.2.2.9
This object holds the Protection group index wherein this ME included in. If this ME is not part of a protection group this value is set to 0.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

sleMplsTpLpsMeCfgControlState 1.3.6.1.4.1.6296.101.16.18.2.2.10
This object represents the operational state of the ME as either primary or backup
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER primary(1), backup(2)