SLE-DEVICE-MIB

File: SLE-DEVICE-MIB.mib (182462 bytes)

Imported modules

DASAN-SMI SLE-TC-MIB SNMPv2-CONF
SNMPv2-SMI

Imported symbols

sleMgmt SleControlStatusType SleControlRequestResultType
OBJECT-GROUP NOTIFICATION-GROUP TimeTicks
IpAddress Integer32 Unsigned32
Gauge32 OBJECT-TYPE MODULE-IDENTITY
NOTIFICATION-TYPE

Defined Types

SleEthernetPortEntry  
SEQUENCE    
  sleEthernetPortIndex INTEGER
  sleEthernetPortPhyIndex Integer32
  sleEthernetPortType INTEGER
  sleEthernetPortAdminStatus INTEGER
  sleEthernetPortOperStatus INTEGER
  sleEthernetPortTransmissionRate Integer32
  sleEthernetPortDuplexMode INTEGER
  sleEthernetPortFlowControl INTEGER
  sleEthernetPortNegotiationMode INTEGER
  sleEthernetPortJumboFrameSize Integer32
  sleEthernetPortSfpTransceiver INTEGER
  sleEthernetPortSfpVendorName OCTET STRING
  sleEthernetPortSfpVendorPartNumber OCTET STRING
  sleEthernetPortSfpVendorRevision OCTET STRING
  sleEthernetPortSfpVendorSerialNumber OCTET STRING
  sleEthernetPortSfpDateCode OCTET STRING
  sleEthernetPortPhysicalRemoteChassis OCTET STRING
  sleEthernetPortPhysicalRemoteSlot Integer32
  sleEthernetPortPhysicalRemotePort Integer32
  sleEthernetPortPhysicalLinkDiscoveryMode INTEGER
  sleEthernetPortSfpTransceiverType INTEGER
  sleEthernetPortSfpTransceiverDetailType INTEGER
  sleEthernetPortSlotIndex Integer32
  sleEthernetPortSlotPortIndex Integer32
  sleEthernetPortAdminTransmissionRate Integer32
  sleEthernetPortAdminDuplexMode INTEGER
  sleEthernetPortAdminFlowControl INTEGER
  sleEthernetPortAdminNegotiationMode INTEGER
  sleEthernetPortAdminReason INTEGER
  sleEthernetPortLinkCheckTimer Integer32
  sleEthernetPortLinkDebounceTime Integer32
  sleEthernetPortCpuStatisticsLimitUnicast Integer32
  sleEthernetPortCpuStatisticsLimitMulticast Integer32
  sleEthernetPortCpuStatisticsLimitBroadcast Integer32
  sleEthernetPortFloodBlockBroadcastState INTEGER
  sleEthernetPortFloodBlockDlfState INTEGER

SleEthernetPortDMIEntry  
SEQUENCE    
  sleEthernetPortDMIIndex INTEGER
  sleEthernetPortDMITemper OCTET STRING
  sleEthernetPortDMIVoltage OCTET STRING
  sleEthernetPortDMITxBias OCTET STRING
  sleEthernetPortDMITxPower OCTET STRING
  sleEthernetPortDMIRxPower OCTET STRING

SleEthernetSFPEntry  
SEQUENCE    
  sleEthernetSfpIndex Integer32
  sleEthernetSfpTransceiver INTEGER
  sleEthernetSfpVendorName OCTET STRING
  sleEthernetSfpVendorPartNumber OCTET STRING
  sleEthernetSfpVendorRevision OCTET STRING
  sleEthernetSfpVendorSerialNumber OCTET STRING
  sleEthernetSfpDateCode OCTET STRING
  sleEthernetSfpTransceiverType INTEGER
  sleEthernetSfpTransceiverDetailType INTEGER
  sleEthernetSfpTransceiverCodes OCTET STRING
  sleEthernetSfpSpeed OCTET STRING
  sleEthernetSfpLength Integer32
  sleEthernetSfpWaveLength Integer32
  sleEthernetSfpMultimodeLengthOm1 Integer32
  sleEthernetSfpMultimodeLengthOm2 Integer32
  sleEthernetSfpMultimodeLengthOm3 Integer32
  sleEthernetSfpTransceiverDetailTypeStr OCTET STRING
  sleEthernetSfpTransceiverLengthStr OCTET STRING
  sleEthernetSfpWaveLengthStr OCTET STRING
  sleEthernetSfpConnectorType OCTET STRING
  sleEthernetSfpDdmState INTEGER
  sleEthernetSfpNegoState INTEGER

SleEthernetSFPThresholdEntry  
SEQUENCE    
  sleEthernetSFPThresholdIfIndex Integer32
  sleEthernetSFPThresholdType INTEGER
  sleEthernetSFPThresholdSfpLow OCTET STRING
  sleEthernetSFPThresholdSfpHigh OCTET STRING
  sleEthernetSFPThresholdSystemLow OCTET STRING
  sleEthernetSFPThresholdSystemHigh OCTET STRING

SlePowerEntry  
SEQUENCE    
  slePowerIndex INTEGER
  slePowerPhyIndex Integer32
  slePowerState INTEGER
  slePowerType INTEGER
  slePowerPSUType INTEGER

SleFanModuleEntry  
SEQUENCE    
  sleFanModuleIndex INTEGER
  sleFanModulePhyIndex Integer32
  sleFanModuleUnitNum Integer32
  sleFanModuleAdminState INTEGER
  sleFanModuleSpeedThreshold Integer32

SleFanUnitEntry  
SEQUENCE    
  sleFanUnitIndex INTEGER
  sleFanUnitOperState INTEGER
  sleFanUnitSpeed Integer32

SleTemperatureEntry  
SEQUENCE    
  sleTemperatureIndex INTEGER
  sleTemperatureState INTEGER
  sleTemperatureValue Integer32
  sleTemperatureHighThreshold Integer32
  sleTemperatureLowThreshold Integer32
  sleTemperatureWarnHighThreshold Integer32
  sleTemperatureWarnLowThreshold Integer32
  sleTemperatureWarnDuration Integer32
  sleTemperatureAlarmHighThreshold Integer32
  sleTemperatureAlarmLowThreshold Integer32
  sleTemperatureAlarmDuration Integer32

SleBatteryEntry  
SEQUENCE    
  sleBatteryIndex INTEGER
  sleOperationPowerType INTEGER
  sleOperationPowerInfo OCTET STRING
  slePSUACPowerState INTEGER
  slePSUTemperture Integer32
  slePSUTempThreshold Integer32
  slePSUOutVoltage OCTET STRING
  slePSUOverTemp INTEGER
  slePSUFirmwareVer Integer32
  sleRBUEquipState INTEGER
  sleRBUModeStaus OCTET STRING
  sleRBUTemperature1 Integer32
  sleRBUTemperature2 Integer32
  sleRBUTempLowThreshold Integer32
  sleRBUOutVoltage OCTET STRING
  sleRBUChargeCurrent Integer32
  sleRBURemainCapacity Integer32
  sleRBUOverTemp INTEGER
  sleBatteryLow INTEGER
  sleRBUTempHighThreshold Integer32
  sleRBUBTStatus INTEGER
  sleRBUBTThreshold Integer32
  sleRBURechargeVoltage Integer32
  sleBatteryCellStatus INTEGER
  sleBPSUACHardwareVer Integer32

SleBatteryBackupEntry  
SEQUENCE    
  sleBatteryBackupFile OCTET STRING

SleClockModuleEntry  
SEQUENCE    
  sleClockModuleIndex INTEGER
  sleClockModuleBoardId INTEGER
  sleClockModuleInstallStatus INTEGER
  sleClockModuleInitStatus INTEGER
  sleClockModuleOPMode INTEGER

SleSlotSystemInfoEntry  
SEQUENCE    
  sleSlotSystemIndex Integer32
  sleSlotSystemUptime TimeTicks
  sleSlotSystemModelName OCTET STRING
  sleSlotSystemSerialNumber OCTET STRING
  sleSlotSystemHWVersion OCTET STRING
  sleSlotSystemBLVersion OCTET STRING
  sleSlotSystemSWCompatibility OCTET STRING
  sleSlotSystemOSVersion OCTET STRING
  sleSlotSystemMacAddress OCTET STRING
  sleSlotSystemCPULoadAll OCTET STRING
  sleSlotSystemCPULoadInterrupt OCTET STRING
  sleSlotSystemMemoryTotal Gauge32
  sleSlotSystemMemoryFree Gauge32
  sleSlotSystemMemoryShared Gauge32
  sleSlotSystemMemoryBuffers Gauge32
  sleSlotSystemMemoryCached Gauge32
  sleSlotSystemMemorySwapTotal Gauge32
  sleSlotSystemMemorySwapFree Gauge32
  sleSlotSystemBootReason INTEGER
  sleSlotSystemBootTime Gauge32
  sleSlotSystemVoltage Gauge32
  sleSlotSystemPowerLevelStatus INTEGER
  sleSlotSystemInfoLEDStatus BITS
  sleSlotSystemInfoPackageVersion OCTET STRING
  sleSlotSystemInfoManufacturer OCTET STRING
  sleSlotSystemInfoManufactureDate OCTET STRING
  sleSlotSystemCPULoadHighThreshold Integer32
  sleSlotSystemCPULoadHighThresholdTimer INTEGER
  sleSlotSystemCPULoadLowThreshold Integer32
  sleSlotSystemCPULoadLowThresholdTimer INTEGER
  sleSlotSystemCPULoadCurrent Integer32
  sleSlotSystemCPUOverallStatus INTEGER
  sleSlotSystemTemperOverallStatus INTEGER

SleSlotStatusInfoEntry  
SEQUENCE    
  sleSlotStatusPlan INTEGER
  sleSlotStatusPlanCardType INTEGER
  sleSlotStatusCurrentInstall INTEGER
  sleSlotStatusCurrentInstallCardType INTEGER
  sleSlotStatusCardOperation INTEGER
  sleSlotStatusLock INTEGER
  sleSlotStatusUpgradeMode INTEGER
  sleSlotStatusActionEvent INTEGER
  sleSlotStatusState INTEGER
  sleSlotStatusPower INTEGER
  sleSlotStatusSerialNumber OCTET STRING
  sleSlotStatusHealthState INTEGER
  sleslotStatusOverallState INTEGER
  sleslotStatusSyncState INTEGER

SleSlotNosInfoEntry  
SEQUENCE    
  sleSlotNosVersion OCTET STRING
  sleSlotNosRevision OCTET STRING
  sleSlotNosSize Unsigned32
  sleSlotNosUpgradeStatus INTEGER
  sleSlotNosStbVersion OCTET STRING
  sleSlotNosStbRevision OCTET STRING
  sleSlotNosStbSize Unsigned32

SleSlotPowerMonEntry  
SEQUENCE    
  sleSlotPowerMonIndex INTEGER
  sleSlotPowerMonStatus INTEGER
  sleSlotPowerMonVoltage Gauge32

SleSlotProtectionIUEntry  
SEQUENCE    
  sleSlotProtectionIUTemperHighThresh Integer32
  sleSlotProtectionIUTemperLowThresh Integer32
  sleSlotProtectionIUPowerThresh Integer32
  sleSlotProtectionIUTemper Integer32
  sleSlotProtectionIUTemper2 Integer32

SleRfPortEntry  
SEQUENCE    
  sleRfPortIndex INTEGER
  sleRfPortAdminStatus INTEGER
  sleRfPortOperStatus INTEGER

SleEMEntry  
SEQUENCE    
  sleEMInputIndex Integer32
  sleEMAlarmString OCTET STRING
  sleEMAlarmSeverity INTEGER
  sleEMmode INTEGER

SleBypassOptionConnectivityEntry  
SEQUENCE    
  sleBypassOptionConnectivityAddress IpAddress
  sleBypassOptionConnectivityPort Integer32

SleBypassOptionPingEntry  
SEQUENCE    
  sleBypassOptionPingAddress IpAddress
  sleBypassOptionPingTransInterval Integer32
  sleBypassOptionPingTranNumber Integer32
  sleBypassOptionPingReqInterval Integer32
  sleBypassOptionPingReqTimeout Integer32
  sleBypassOptionPingLossThresh Integer32

SleBypassOptionLinkMonitorEntry  
SEQUENCE    
  sleBypassOptionLinkMonitorPort Integer32
  sleBypassOptionLinkMonitorPortStatus INTEGER

SleHFCEntry  
SEQUENCE    
  sleHFCOptic1550OTX OCTET STRING
  sleHFCOptic1550OTXAlarm INTEGER
  sleHFCOpticUpstreamOTX OCTET STRING
  sleHFCOpticUpstreamOTXAlarm INTEGER
  sleHFCOpticDownstreamORX OCTET STRING
  sleHFCOpticDownstreamORXAlarm INTEGER
  sleHFCEDFA1OTX OCTET STRING
  sleHFCEDFA1OTXAlarm INTEGER
  sleHFCEDFA1ORX OCTET STRING
  sleHFCEDFA1ORXAlarm INTEGER
  sleHFCEDFA1LD1Current OCTET STRING
  sleHFCEDFA1LD1CurrentAlarm INTEGER
  sleHFCEDFA1LD2Current OCTET STRING
  sleHFCEDFA1LD2CurrentAlarm INTEGER
  sleHFCEDFA1LD1Temp OCTET STRING
  sleHFCEDFA1LD1TempAlarm INTEGER
  sleHFCEDFA1LD2Temp OCTET STRING
  sleHFCEDFA1LD2TempAlarm INTEGER
  sleHFCEDFA1CaseTemp OCTET STRING
  sleHFCEDFA1CaseTempAlarm INTEGER
  sleHFCEDFA2OTX OCTET STRING
  sleHFCEDFA2OTXAarm INTEGER
  sleHFCEDFA2ORX OCTET STRING
  sleHFCEDFA2ORXAlarm INTEGER
  sleHFCEDFA2LD1Current OCTET STRING
  sleHFCEDFA2LD1CurrentAlarm INTEGER
  sleHFCEDFA2LD2Current OCTET STRING
  sleHFCEDFA2LD2CurrentAlarm INTEGER
  sleHFCEDFA2LD1Temp OCTET STRING
  sleHFCEDFA2LD1TempAlarm INTEGER
  sleHFCEDFA2LD2Temp OCTET STRING
  sleHFCEDFA2LD2TempAlarm INTEGER
  sleHFCEDFA2CaseTemp OCTET STRING
  sleHFCEDFA2CaseTempAlarm INTEGER

Defined Values

sleDevice 1.3.6.1.4.1.6296.101.2
Description.
MODULE-IDENTITY    

sleDeviceBase 1.3.6.1.4.1.6296.101.2.1
OBJECT IDENTIFIER    

sleDeviceBaseInfo 1.3.6.1.4.1.6296.101.2.1.1
OBJECT IDENTIFIER    

sleDeviceEthernetPortNum 1.3.6.1.4.1.6296.101.2.1.1.1
The number of ethernet port.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sleDevicePowerNum 1.3.6.1.4.1.6296.101.2.1.1.2
The number of power module
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sleDeviceFanModuleNum 1.3.6.1.4.1.6296.101.2.1.1.3
The number of FAN module
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sleDeviceTemperatureNum 1.3.6.1.4.1.6296.101.2.1.1.4
The number of temperature sensor
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sleDeviceFanStartTemperature 1.3.6.1.4.1.6296.101.2.1.1.5
The temperature value which begins to turn fan.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sleDeviceFanStopTemperature 1.3.6.1.4.1.6296.101.2.1.1.6
The temperature value which stops fan.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sleDeviceJumboFrameStatus 1.3.6.1.4.1.6296.101.2.1.1.7
The global jumbo-frame status. 2011/01/20 V5924CR only support this.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

sleDeviceEnvironmentMonitoringStatus 1.3.6.1.4.1.6296.101.2.1.1.8
The alarm input mode of environment monitoring for AIU
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notInstallAIU(0), normalOpen(1), normalClose(2)  

sleDeviceBaseControl 1.3.6.1.4.1.6296.101.2.1.2
OBJECT IDENTIFIER    

sleDeviceControlRequest 1.3.6.1.4.1.6296.101.2.1.2.1
set an administrative state of FAN module
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER setDeviceTemperatureThreshold(1), setDeviceJumboFrameStatus(2), setDeviceLEDTest(3), setEnvironmentMonitoringStatus(4)  

sleDeviceControlStatus 1.3.6.1.4.1.6296.101.2.1.2.2
Description.
Status: current Access: read-only
OBJECT-TYPE    
  SleControlStatusType  

sleDeviceControlTimer 1.3.6.1.4.1.6296.101.2.1.2.3
Description.
Status: current Access: read-write
OBJECT-TYPE    
  Gauge32  

sleDeviceControlTimeStamp 1.3.6.1.4.1.6296.101.2.1.2.4
Description.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

sleDeviceControlReqResult 1.3.6.1.4.1.6296.101.2.1.2.5
Description.
Status: current Access: read-only
OBJECT-TYPE    
  SleControlRequestResultType  

sleDeviceControlFanStartTemperature 1.3.6.1.4.1.6296.101.2.1.2.6
Description.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

sleDeviceControlFanStopTemperature 1.3.6.1.4.1.6296.101.2.1.2.7
Description.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

sleDeviceControlJumboFrameStatus 1.3.6.1.4.1.6296.101.2.1.2.8
The global jumbo-frame status. 2011/01/20 V5924CR only support this.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

sleDeviceControlEnvironmentMonitoringStatus 1.3.6.1.4.1.6296.101.2.1.2.9
The alarm input mode of environment monitoring for AIU
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normalOpen(1), normalClose(2)  

sleDeviceBaseNotification 1.3.6.1.4.1.6296.101.2.1.3
OBJECT IDENTIFIER    

sleDeviceTemperatureThresholdChanged 1.3.6.1.4.1.6296.101.2.1.3.1
Description.
Status: current Access: read-only
NOTIFICATION-TYPE    

sleDeviceJumboFrameChanged 1.3.6.1.4.1.6296.101.2.1.3.2
Description.
Status: current Access: read-only
NOTIFICATION-TYPE    

sleDeviceLEDTestChanged 1.3.6.1.4.1.6296.101.2.1.3.3
Description.
Status: current Access: read-only
NOTIFICATION-TYPE    

sleDeviceEnvironmentMonitoringStatusChanged 1.3.6.1.4.1.6296.101.2.1.3.4
setEnvironmentMonitoringStatus
Status: current Access: read-only
NOTIFICATION-TYPE    

sleEthernetPort 1.3.6.1.4.1.6296.101.2.2
OBJECT IDENTIFIER    

sleEthernetPortTable 1.3.6.1.4.1.6296.101.2.2.1
Description.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SleEthernetPortEntry

sleEthernetPortEntry 1.3.6.1.4.1.6296.101.2.2.1.1
Description.
Status: current Access: not-accessible
OBJECT-TYPE    
  SleEthernetPortEntry  

sleEthernetPortIndex 1.3.6.1.4.1.6296.101.2.2.1.1.1
The port index.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

sleEthernetPortPhyIndex 1.3.6.1.4.1.6296.101.2.2.1.1.2
The physical index of entity mib.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sleEthernetPortType 1.3.6.1.4.1.6296.101.2.2.1.1.3
The type of port. It is not planed to made a automatic switchover between optical and electrical interfaces.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(0), electrical(1), optical(2)  

sleEthernetPortAdminStatus 1.3.6.1.4.1.6296.101.2.2.1.1.4
The admin status of port.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER up(1), down(2), notAvailable(3)  

sleEthernetPortOperStatus 1.3.6.1.4.1.6296.101.2.2.1.1.5
The oper status of port
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER up(1), down(2), notAvailable(3)  

sleEthernetPortTransmissionRate 1.3.6.1.4.1.6296.101.2.2.1.1.6
The speed of port. Unit is Mbit/s. This configurations are only useful for electrical interfaces. Optical - interfaces will always support 1000 MBIT/s
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 10 | 100 | 1000 | 2500 | 10000  

sleEthernetPortDuplexMode 1.3.6.1.4.1.6296.101.2.2.1.1.7
The duplex status of port.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER full(1), half(2), notAvailable(3)  

sleEthernetPortFlowControl 1.3.6.1.4.1.6296.101.2.2.1.1.8
The flow-control mode of port.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER disabled(1), enabledSymetrical(2), enabledAsymetrical(3), enabledBoth(4), notAvailable(5)  

sleEthernetPortNegotiationMode 1.3.6.1.4.1.6296.101.2.2.1.1.9
The Auto Negotiation mode of port.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER auto(1), force(2), notAvailable(3)  

sleEthernetPortJumboFrameSize 1.3.6.1.4.1.6296.101.2.2.1.1.10
The jumbo frame's size of port. If the value is zero, it means that it is not set up.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0 | 1518..12288  

sleEthernetPortSfpTransceiver 1.3.6.1.4.1.6296.101.2.2.1.1.11
Description.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(0), electrical(1), electricalCoaxial(2), opticalLongHaul(3), opticalShortHaul(4), optical10G(5), opticalGpon(6)  

sleEthernetPortSfpVendorName 1.3.6.1.4.1.6296.101.2.2.1.1.12
Description.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleEthernetPortSfpVendorPartNumber 1.3.6.1.4.1.6296.101.2.2.1.1.13
Description.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleEthernetPortSfpVendorRevision 1.3.6.1.4.1.6296.101.2.2.1.1.14
Description.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleEthernetPortSfpVendorSerialNumber 1.3.6.1.4.1.6296.101.2.2.1.1.15
Description.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleEthernetPortSfpDateCode 1.3.6.1.4.1.6296.101.2.2.1.1.16
Description.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleEthernetPortPhysicalRemoteChassis 1.3.6.1.4.1.6296.101.2.2.1.1.17
Description.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleEthernetPortPhysicalRemoteSlot 1.3.6.1.4.1.6296.101.2.2.1.1.18
Description.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sleEthernetPortPhysicalRemotePort 1.3.6.1.4.1.6296.101.2.2.1.1.19
Description.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sleEthernetPortPhysicalLinkDiscoveryMode 1.3.6.1.4.1.6296.101.2.2.1.1.20
Description.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(1), manual(2), automatic(3)  

sleEthernetPortSfpTransceiverType 1.3.6.1.4.1.6296.101.2.2.1.1.21
The type of SFP transceiver.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER sfp(1), gbit(2), xfp(3), unknown(255)  

sleEthernetPortSfpTransceiverDetailType 1.3.6.1.4.1.6296.101.2.2.1.1.22
The detailed-type of SFP transceiver.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER fiber1000Sx(1), fiber1000Lx(2), fiber1000Cx(3), fiber1000T(4), fiber100lLxLx10(5), fiber100Fx(6), fiberBx10(7), fiberPx(8), fiberOc3MmSr(9), fiberOc3SmIr(10), fiberOc3SmLr(11), fiber1000Zx(12), unknown(255)  

sleEthernetPortSlotIndex 1.3.6.1.4.1.6296.101.2.2.1.1.23
The slot index.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sleEthernetPortSlotPortIndex 1.3.6.1.4.1.6296.101.2.2.1.1.24
The slot's port index.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sleEthernetPortAdminTransmissionRate 1.3.6.1.4.1.6296.101.2.2.1.1.25
The speed of port. Unit is Mbit/s. This configurations are only useful for electrical interfaces. Optical - interfaces will always support 1000 MBIT/s
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 10 | 100 | 1000 | 10000  

sleEthernetPortAdminDuplexMode 1.3.6.1.4.1.6296.101.2.2.1.1.26
The duplex status of port.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER full(1), half(2), notAvailable(255)  

sleEthernetPortAdminFlowControl 1.3.6.1.4.1.6296.101.2.2.1.1.27
The flow-control mode of port.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER disabled(1), enableSend(2), enableReceive(3), enabledBoth(4)  

sleEthernetPortAdminNegotiationMode 1.3.6.1.4.1.6296.101.2.2.1.1.28
The Auto Negotiation mode of port.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER auto(1), force(2), notAvailable(255)  

sleEthernetPortAdminReason 1.3.6.1.4.1.6296.101.2.2.1.1.29
The admin down reason of the interface. user : by user-configuration xllcf : by xllcf protocol all : both user and xllcf
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(0), user(1), xllcf(2), all(3)  

sleEthernetPortLinkCheckTimer 1.3.6.1.4.1.6296.101.2.2.1.1.30
The Link check internval of the interface
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 20..1000  

sleEthernetPortLinkDebounceTime 1.3.6.1.4.1.6296.101.2.2.1.1.31
The link debounce time of the interface
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0 | 10..5000  

sleEthernetPortCpuStatisticsLimitUnicast 1.3.6.1.4.1.6296.101.2.2.1.1.32
The CPU statistics-limit Unicast Count ( the standard unit : 1000, 10 = 1000 )
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0 | 10..100  

sleEthernetPortCpuStatisticsLimitMulticast 1.3.6.1.4.1.6296.101.2.2.1.1.33
et CPU statistics-limit Multicast Count ( the standard unit : 1000, 10 = 1000 )
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0 | 10..100  

sleEthernetPortCpuStatisticsLimitBroadcast 1.3.6.1.4.1.6296.101.2.2.1.1.34
Set CPU statistics-limit Broadcast Count ( the standard unit : 1000, 10 = 1000 )
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0 | 10..100  

sleEthernetPortFloodBlockBroadcastState 1.3.6.1.4.1.6296.101.2.2.1.1.35
The Flood Block Broadcast State of the interface
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER disable(0), enable(1)  

sleEthernetPortFloodBlockDlfState 1.3.6.1.4.1.6296.101.2.2.1.1.36
The Flood Block DLF State of the interface
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER disable(0), enable(1)  

sleEthernetPortControl 1.3.6.1.4.1.6296.101.2.2.2
OBJECT IDENTIFIER    

sleEthernetPortControlRequest 1.3.6.1.4.1.6296.101.2.2.2.1
Description.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER setEthernetPortProfile(1), setEthernetPortLinkProfile(2), setEhternetPortCpuStatisticsLimitProfile(3), setEthernetPortFloodBlockStateProfile(4)  

sleEthernetPortControlStatus 1.3.6.1.4.1.6296.101.2.2.2.2
Description.
Status: current Access: read-only
OBJECT-TYPE    
  SleControlStatusType  

sleEthernetPortControlTimer 1.3.6.1.4.1.6296.101.2.2.2.3
Description.
Status: current Access: read-write
OBJECT-TYPE    
  Gauge32  

sleEthernetPortControlTimeStamp 1.3.6.1.4.1.6296.101.2.2.2.4
Description.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

sleEthernetPortControlReqResult 1.3.6.1.4.1.6296.101.2.2.2.5
Description.
Status: current Access: read-only
OBJECT-TYPE    
  SleControlRequestResultType  

sleEthernetPortControlIndex 1.3.6.1.4.1.6296.101.2.2.2.6
Description.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

sleEthernetPortControlType 1.3.6.1.4.1.6296.101.2.2.2.7
Description.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unknown(0), electrical(1), optical(2)  

sleEthernetPortControlAdminStatus 1.3.6.1.4.1.6296.101.2.2.2.8
Description.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER up(1), down(2), notAvailable(3)  

sleEthernetPortControlTransmissionRate 1.3.6.1.4.1.6296.101.2.2.2.9
Description.The speed of port. Unit is Mbit/s. This configurations are only useful for electrical interfaces. Optical - interfaces will always support 1000 MBIT/s
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 10 | 100 | 1000 | 2500 | 10000  

sleEthernetPortControlDuplexMode 1.3.6.1.4.1.6296.101.2.2.2.10
Description.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER full(1), half(2), notAvailable(3)  

sleEthernetPortControlFlowControl 1.3.6.1.4.1.6296.101.2.2.2.11
Description.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabledSymetrical(2), enabledAsymetrical(3), enabledBoth(4), notAvailable(5)  

sleEthernetPortControlNegotiationMode 1.3.6.1.4.1.6296.101.2.2.2.12
Description.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER auto(1), force(2), notAvailable(3)  

sleEthernetPortControlJumboFrameSize 1.3.6.1.4.1.6296.101.2.2.2.13
Description. If the value is zero, it means erasing the set-up value.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0 | 1518..12288  

sleEthernetPortControlPhysicalRemoteChassis 1.3.6.1.4.1.6296.101.2.2.2.14
Description.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

sleEthernetPortControlPhysicalRemoteSlot 1.3.6.1.4.1.6296.101.2.2.2.15
Description.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

sleEthernetPortControlPhysicalRemotePort 1.3.6.1.4.1.6296.101.2.2.2.16
Description.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

sleEthernetPortControlPhysicalLinkDiscoveryMode 1.3.6.1.4.1.6296.101.2.2.2.17
Description.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), manual(2), automatic(3)  

sleEthernetPortControlLinkCheckTimer 1.3.6.1.4.1.6296.101.2.2.2.18
The Link check internval of the interface
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 20..1000  

sleEthernetPortControlLinkDebounceTime 1.3.6.1.4.1.6296.101.2.2.2.19
The link debounce time of the interface
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0 | 10..5000  

sleEthernetPortControlCpuStatisticsLimitUnicast 1.3.6.1.4.1.6296.101.2.2.2.20
The CPU statistics-limit Unicast Count ( the standard unit : 1000, 10 = 1000 )
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0 | 10..100  

sleEthernetPortControlCpuStatisticsLimitMulticast 1.3.6.1.4.1.6296.101.2.2.2.21
et CPU statistics-limit Multicast Count ( the standard unit : 1000, 10 = 1000 )
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0 | 10..100  

sleEthernetPortControlCpuStatisticsLimitBroadcast 1.3.6.1.4.1.6296.101.2.2.2.22
Set CPU statistics-limit Broadcast Count ( the standard unit : 1000, 10 = 1000 )
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0 | 10..100  

sleEthernetPortControlFloodBlockBroadcastState 1.3.6.1.4.1.6296.101.2.2.2.23
The Flood Block Broadcast State of the interface
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(0), enable(1)  

sleEthernetPortControlFloodBlockDlfState 1.3.6.1.4.1.6296.101.2.2.2.24
The Flood Block DLF State of the interface
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(0), enable(1)  

sleEthernetPortNotification 1.3.6.1.4.1.6296.101.2.2.3
OBJECT IDENTIFIER    

sleEthernetPortChanged 1.3.6.1.4.1.6296.101.2.2.3.1
Description.
Status: current Access: read-write
NOTIFICATION-TYPE    

sleEthernetPortLinkChanged 1.3.6.1.4.1.6296.101.2.2.3.2
setEthernetPortLinkProfile
Status: current Access: read-write
NOTIFICATION-TYPE    

sleEthernetPortCpuStatisticsLimitChanged 1.3.6.1.4.1.6296.101.2.2.3.3
setEhternetPortCpuStatisticsLimitProfile
Status: current Access: read-write
NOTIFICATION-TYPE    

sleEthernetPortFloodBlockStateChanged 1.3.6.1.4.1.6296.101.2.2.3.4
setEthernetPortFloodBlockStateProfile
Status: current Access: read-write
NOTIFICATION-TYPE    

sleEthernetPortDMITable 1.3.6.1.4.1.6296.101.2.2.4
Description.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SleEthernetPortDMIEntry

sleEthernetPortDMIEntry 1.3.6.1.4.1.6296.101.2.2.4.1
Description.
Status: current Access: not-accessible
OBJECT-TYPE    
  SleEthernetPortDMIEntry  

sleEthernetPortDMIIndex 1.3.6.1.4.1.6296.101.2.2.4.1.1
Port Index.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

sleEthernetPortDMITemper 1.3.6.1.4.1.6296.101.2.2.4.1.2
Internally measured module temperature.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleEthernetPortDMIVoltage 1.3.6.1.4.1.6296.101.2.2.4.1.3
Internally measured supply voltage in transceiver.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleEthernetPortDMITxBias 1.3.6.1.4.1.6296.101.2.2.4.1.4
Internally measured TX Bias Current.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleEthernetPortDMITxPower 1.3.6.1.4.1.6296.101.2.2.4.1.5
Measured TX output power.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleEthernetPortDMIRxPower 1.3.6.1.4.1.6296.101.2.2.4.1.6
Measured RX input power.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleEthernetSFPTable 1.3.6.1.4.1.6296.101.2.2.5
Description.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SleEthernetSFPEntry

sleEthernetSFPEntry 1.3.6.1.4.1.6296.101.2.2.5.1
Description.
Status: current Access: not-accessible
OBJECT-TYPE    
  SleEthernetSFPEntry  

sleEthernetSfpIndex 1.3.6.1.4.1.6296.101.2.2.5.1.1
The SFP index.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..65556  

sleEthernetSfpTransceiver 1.3.6.1.4.1.6296.101.2.2.5.1.2
The type of SFP
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(0), electrical(1), electricalCoaxial(2), opticalLongHaul(3), opticalShortHaul(4), optical10G(5), opticalGpon(6)  

sleEthernetSfpVendorName 1.3.6.1.4.1.6296.101.2.2.5.1.3
The vendor name of SFP
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleEthernetSfpVendorPartNumber 1.3.6.1.4.1.6296.101.2.2.5.1.4
The part number of SFP
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleEthernetSfpVendorRevision 1.3.6.1.4.1.6296.101.2.2.5.1.5
The revision of SFP
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleEthernetSfpVendorSerialNumber 1.3.6.1.4.1.6296.101.2.2.5.1.6
The serial number of SFP
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleEthernetSfpDateCode 1.3.6.1.4.1.6296.101.2.2.5.1.7
The manufacturing date of SFP
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleEthernetSfpTransceiverType 1.3.6.1.4.1.6296.101.2.2.5.1.8
The type of SFP transceiver.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER sfp(1), gbic(2), xfp(3), unknown(255)  

sleEthernetSfpTransceiverDetailType 1.3.6.1.4.1.6296.101.2.2.5.1.9
The detailed-type of SFP transceiver.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER fiber1000Sx(1), fiber1000Lx(2), fiber1000Cx(3), fiber1000T(4), fiber100lLxLx10(5), fiber100Fx(6), fiberBx10(7), fiberPx(8), fiberOc3MmSr(9), fiberOc3SmIr(10), fiberOc3SmLr(11), fiber1000Zx(12), base10GSR(64), base10GLR(65), base10GER(66), base10GLRM(67), base10GSW(68), base10GLW(69), base10GEW(70), base10GEWorZW(71), unknown(255)  

sleEthernetSfpTransceiverCodes 1.3.6.1.4.1.6296.101.2.2.5.1.10
The transceiver codes. In case of SFP, reference SFP-8472 Rev 11.0 - Table 3.5: Transceiver codes (Address A0h) - Table 3.5a: SONET Compliance Specifiers (A0h) In case of XFP, reference XFP Specification Revision 4.5 (August 31,2005) - Table 40 Transceiver codes
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1..8)  

sleEthernetSfpSpeed 1.3.6.1.4.1.6296.101.2.2.5.1.11
The speed of SFP
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleEthernetSfpLength 1.3.6.1.4.1.6296.101.2.2.5.1.12
The length of SFP
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sleEthernetSfpWaveLength 1.3.6.1.4.1.6296.101.2.2.5.1.13
The wavelength of SFP
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sleEthernetSfpMultimodeLengthOm1 1.3.6.1.4.1.6296.101.2.2.5.1.14
The Flame rating is 62.5um(OM1). This is used only for 10G SFP module with multi-mode. ref) 50/125 Multimode Fiber Optic 50/125 is one of the most commonly used multimode optical fiber, the other commonly used is 62.5/125 types. There is a special kind 50/125 multimode fibers, which is called OM3 50/125. People usually refer 62.5/125 as the OM1 MMF, common type 50/125 MMF as OM2, OM3 is also 50/125, but it is different from OM2 because it support 10Gig data transmission. The OM3 50/125 fiber optic cable is also called laser optimized fiber cable. Both OM1 and OM2 multimode cables use the orange color jacket (standard practice for commonly used indoor multimode), OM3 use a special color, which is called Aqua.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sleEthernetSfpMultimodeLengthOm2 1.3.6.1.4.1.6296.101.2.2.5.1.15
The Flame rating is 50um(OM2). This is used only for 10G SFP module with multi-mode. ref) 50/125 Multimode Fiber Optic 50/125 is one of the most commonly used multimode optical fiber, the other commonly used is 62.5/125 types. There is a special kind 50/125 multimode fibers, which is called OM3 50/125. People usually refer 62.5/125 as the OM1 MMF, common type 50/125 MMF as OM2, OM3 is also 50/125, but it is different from OM2 because it support 10Gig data transmission. The OM3 50/125 fiber optic cable is also called laser optimized fiber cable. Both OM1 and OM2 multimode cables use the orange color jacket (standard practice for commonly used indoor multimode), OM3 use a special color, which is called Aqua.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sleEthernetSfpMultimodeLengthOm3 1.3.6.1.4.1.6296.101.2.2.5.1.16
The Flame rating is 50um(OM3). This is used only for 10G SFP module with multi-mode. ref) 50/125 Multimode Fiber Optic 50/125 is one of the most commonly used multimode optical fiber, the other commonly used is 62.5/125 types. There is a special kind 50/125 multimode fibers, which is called OM3 50/125. People usually refer 62.5/125 as the OM1 MMF, common type 50/125 MMF as OM2, OM3 is also 50/125, but it is different from OM2 because it support 10Gig data transmission. The OM3 50/125 fiber optic cable is also called laser optimized fiber cable. Both OM1 and OM2 multimode cables use the orange color jacket (standard practice for commonly used indoor multimode), OM3 use a special color, which is called Aqua.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sleEthernetSfpTransceiverDetailTypeStr 1.3.6.1.4.1.6296.101.2.2.5.1.17
Description.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleEthernetSfpTransceiverLengthStr 1.3.6.1.4.1.6296.101.2.2.5.1.18
Description.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleEthernetSfpWaveLengthStr 1.3.6.1.4.1.6296.101.2.2.5.1.19
Description.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleEthernetSfpConnectorType 1.3.6.1.4.1.6296.101.2.2.5.1.20
Description.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleEthernetSfpDdmState 1.3.6.1.4.1.6296.101.2.2.5.1.21
The DDM state
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER disable(0), enable(1)  

sleEthernetSfpNegoState 1.3.6.1.4.1.6296.101.2.2.5.1.22
The Nego state
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(0), on(1)  

sleEthernetSFPControl 1.3.6.1.4.1.6296.101.2.2.6
OBJECT IDENTIFIER    

sleEthernetSFPControlRequest 1.3.6.1.4.1.6296.101.2.2.6.1
Description.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER setSFPRemoteReset(1), setSFPDdmState(2)  

sleEthernetSFPControlStatus 1.3.6.1.4.1.6296.101.2.2.6.2
Description.
Status: current Access: read-only
OBJECT-TYPE    
  SleControlStatusType  

sleEthernetSFPControlTimer 1.3.6.1.4.1.6296.101.2.2.6.3
Description.
Status: current Access: read-write
OBJECT-TYPE    
  Gauge32  

sleEthernetSFPControlTimeStamp 1.3.6.1.4.1.6296.101.2.2.6.4
Description.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

sleEthernetSFPControlReqResult 1.3.6.1.4.1.6296.101.2.2.6.5
Description.
Status: current Access: read-only
OBJECT-TYPE    
  SleControlRequestResultType  

sleEthernetSFPControlIndex 1.3.6.1.4.1.6296.101.2.2.6.6
Description.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

sleEthernetSfpControlDdmState 1.3.6.1.4.1.6296.101.2.2.6.7
Description.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(0), enable(1)  

sleEthernetSFPNotification 1.3.6.1.4.1.6296.101.2.2.7
OBJECT IDENTIFIER    

sleEthernetSFPRemoteReset 1.3.6.1.4.1.6296.101.2.2.7.1
setSFPRemoteReset
Status: current Access: read-write
NOTIFICATION-TYPE    

sleEthernetSFPDdmState 1.3.6.1.4.1.6296.101.2.2.7.2
setSFPDdmState
Status: current Access: read-write
NOTIFICATION-TYPE    

sleEthernetSFPThresholdTable 1.3.6.1.4.1.6296.101.2.2.8
Description.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SleEthernetSFPThresholdEntry

sleEthernetSFPThresholdEntry 1.3.6.1.4.1.6296.101.2.2.8.1
Description.
Status: current Access: not-accessible
OBJECT-TYPE    
  SleEthernetSFPThresholdEntry  

sleEthernetSFPThresholdIfIndex 1.3.6.1.4.1.6296.101.2.2.8.1.1
The index of the interface
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..65535  

sleEthernetSFPThresholdType 1.3.6.1.4.1.6296.101.2.2.8.1.2
The Type of Threshold
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER temperWarning(1), temperAlarm(2), voltageWarning(3), voltageAlarm(4), txbiasWarning(5), txbiasAlarm(6), txpowerWarning(7), txpowerAlarm(8), rxpowerWarning(9), rxpowerAlarm(10)  

sleEthernetSFPThresholdSfpLow 1.3.6.1.4.1.6296.101.2.2.8.1.3
The Threshold Low Value of Sfp
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleEthernetSFPThresholdSfpHigh 1.3.6.1.4.1.6296.101.2.2.8.1.4
The Threshold High Value of Sfp
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleEthernetSFPThresholdSystemLow 1.3.6.1.4.1.6296.101.2.2.8.1.5
The Threshold Low Value of System
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleEthernetSFPThresholdSystemHigh 1.3.6.1.4.1.6296.101.2.2.8.1.6
The Threshold High Value of System
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleEthernetSFPThresholdControl 1.3.6.1.4.1.6296.101.2.2.9
OBJECT IDENTIFIER    

sleEthernetSFPThresholdControlRequest 1.3.6.1.4.1.6296.101.2.2.9.1
Description.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER setSfpThresholdModule(1), setSystemThresholdModule(2), delThresholdModule(3)  

sleEthernetSFPThresholdControlStatus 1.3.6.1.4.1.6296.101.2.2.9.2
Description.
Status: current Access: read-only
OBJECT-TYPE    
  SleControlStatusType  

sleEthernetSFPThresholdControlTimer 1.3.6.1.4.1.6296.101.2.2.9.3
Description.
Status: current Access: read-write
OBJECT-TYPE    
  Gauge32  

sleEthernetSFPThresholdControlTimeStamp 1.3.6.1.4.1.6296.101.2.2.9.4
Description.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

sleEthernetSFPThresholdControlReqResult 1.3.6.1.4.1.6296.101.2.2.9.5
Description.
Status: current Access: read-only
OBJECT-TYPE    
  SleControlRequestResultType  

sleEthernetSFPThresholdControlIfIndex 1.3.6.1.4.1.6296.101.2.2.9.6
The index of the interface
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

sleEthernetSFPThresholdControlType 1.3.6.1.4.1.6296.101.2.2.9.7
The Type of Threshold
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER temperWarning(1), temperAlarm(2), voltageWarning(3), voltageAlarm(4), txbiasWarning(5), txbiasAlarm(6), txpowerWarning(7), txpowerAlarm(8), rxpowerWarning(9), rxpowerAlarm(10)  

sleEthernetSFPThresholdControlSfpLow 1.3.6.1.4.1.6296.101.2.2.9.8
The Threshold Low Value of Sfp
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

sleEthernetSFPThresholdControlSfpHigh 1.3.6.1.4.1.6296.101.2.2.9.9
The Threshold High Value of Sfp
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

sleEthernetSFPThresholdControlSystemLow 1.3.6.1.4.1.6296.101.2.2.9.10
The Threshold Low Value of System
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

sleEthernetSFPThresholdControlSystemHigh 1.3.6.1.4.1.6296.101.2.2.9.11
The Threshold High Value of System
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

sleEthernetSFPThresholdNotification 1.3.6.1.4.1.6296.101.2.2.10
OBJECT IDENTIFIER    

sleEthernetSFPThresholdSfpChanged 1.3.6.1.4.1.6296.101.2.2.10.1
setSfpThresholdModule
Status: current Access: read-write
NOTIFICATION-TYPE    

sleEthernetSFPThresholdSystemChanged 1.3.6.1.4.1.6296.101.2.2.10.2
setSystemThresholdModule
Status: current Access: read-write
NOTIFICATION-TYPE    

sleEthernetSFPThresholdDestroyed 1.3.6.1.4.1.6296.101.2.2.10.3
delThresholdModule
Status: current Access: read-write
NOTIFICATION-TYPE    

slePower 1.3.6.1.4.1.6296.101.2.3
OBJECT IDENTIFIER    

slePowerTable 1.3.6.1.4.1.6296.101.2.3.1
Description.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SlePowerEntry

slePowerEntry 1.3.6.1.4.1.6296.101.2.3.1.1
Description.
Status: current Access: not-accessible
OBJECT-TYPE    
  SlePowerEntry  

slePowerIndex 1.3.6.1.4.1.6296.101.2.3.1.1.1
A unique value, greater than zero, for each module. It is recommended that values are assigned contiguously starting from 1. The value for each interface sub-layer must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

slePowerPhyIndex 1.3.6.1.4.1.6296.101.2.3.1.1.2
entPhysicalIndex of Power Modules (0: Internal, -1: uninstalled)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slePowerState 1.3.6.1.4.1.6296.101.2.3.1.1.3
Power status information.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER failure(0), ok(1)  

slePowerType 1.3.6.1.4.1.6296.101.2.3.1.1.4
Power type information.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER ac(1), dc(2), unknown(3), psu(4)  

slePowerPSUType 1.3.6.1.4.1.6296.101.2.3.1.1.5
The type of Power Supply Unit.(DC)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER psuA(1), psuS(2), unknown(255)  

sleFanModule 1.3.6.1.4.1.6296.101.2.4
OBJECT IDENTIFIER    

sleFanModuleTable 1.3.6.1.4.1.6296.101.2.4.1
Description.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SleFanModuleEntry

sleFanModuleEntry 1.3.6.1.4.1.6296.101.2.4.1.1
Description.
Status: current Access: not-accessible
OBJECT-TYPE    
  SleFanModuleEntry  

sleFanModuleIndex 1.3.6.1.4.1.6296.101.2.4.1.1.1
A unique value, greater than zero, for each module. It is recommended that values are assigned contiguously starting from 1.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

sleFanModulePhyIndex 1.3.6.1.4.1.6296.101.2.4.1.1.2
entPhysicalIndex of FAN Modules. (0: Internal, -1: uninstalled)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sleFanModuleUnitNum 1.3.6.1.4.1.6296.101.2.4.1.1.3
The number of unit in FAN module
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sleFanModuleAdminState 1.3.6.1.4.1.6296.101.2.4.1.1.4
An administrative state of FAN module
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(0), on(1), auto(2)  

sleFanModuleSpeedThreshold 1.3.6.1.4.1.6296.101.2.4.1.1.5
Fan-speed threshold
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sleFanModuleControl 1.3.6.1.4.1.6296.101.2.4.2
OBJECT IDENTIFIER    

sleFanModuleControlRequest 1.3.6.1.4.1.6296.101.2.4.2.1
set an administrative state of FAN module
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER setFanAdminState(1), setFanSpeedThreshold(2)  

sleFanModuleControlStatus 1.3.6.1.4.1.6296.101.2.4.2.2
Description.
Status: current Access: read-only
OBJECT-TYPE    
  SleControlStatusType  

sleFanModuleControlTimer 1.3.6.1.4.1.6296.101.2.4.2.3
Description.
Status: current Access: read-write
OBJECT-TYPE    
  Gauge32  

sleFanModuleControlTimeStamp 1.3.6.1.4.1.6296.101.2.4.2.4
Description.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

sleFanModuleControlReqResult 1.3.6.1.4.1.6296.101.2.4.2.5
Description.
Status: current Access: read-only
OBJECT-TYPE    
  SleControlRequestResultType  

sleFanModuleControlIndex 1.3.6.1.4.1.6296.101.2.4.2.6
Description.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

sleFanModuleControlAdminState 1.3.6.1.4.1.6296.101.2.4.2.7
An administrative state of FAN module
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(0), on(1), auto(2)  

sleFanModuleControlSpeedThreshold 1.3.6.1.4.1.6296.101.2.4.2.8
Fan-speed threshold
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

sleFanModuleNotification 1.3.6.1.4.1.6296.101.2.4.3
OBJECT IDENTIFIER    

sleFanAdminStateChanged 1.3.6.1.4.1.6296.101.2.4.3.1
Description.
Status: current Access: read-write
NOTIFICATION-TYPE    

sleFanSpeedThresholdChanged 1.3.6.1.4.1.6296.101.2.4.3.2
Description.
Status: current Access: read-write
NOTIFICATION-TYPE    

sleFanUnit 1.3.6.1.4.1.6296.101.2.5
OBJECT IDENTIFIER    

sleFanUnitTable 1.3.6.1.4.1.6296.101.2.5.1
Description.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SleFanUnitEntry

sleFanUnitEntry 1.3.6.1.4.1.6296.101.2.5.1.1
Description.
Status: current Access: not-accessible
OBJECT-TYPE    
  SleFanUnitEntry  

sleFanUnitIndex 1.3.6.1.4.1.6296.101.2.5.1.1.1
A unique number in FAN module
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

sleFanUnitOperState 1.3.6.1.4.1.6296.101.2.5.1.1.2
An operational state of FAN unit
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER failure(0), ok(1), stop(2)  

sleFanUnitSpeed 1.3.6.1.4.1.6296.101.2.5.1.1.3
Speed of FAN unit
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sleTemperature 1.3.6.1.4.1.6296.101.2.6
OBJECT IDENTIFIER    

sleTemperatureTable 1.3.6.1.4.1.6296.101.2.6.1
Description.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SleTemperatureEntry

sleTemperatureEntry 1.3.6.1.4.1.6296.101.2.6.1.1
Description.
Status: current Access: not-accessible
OBJECT-TYPE    
  SleTemperatureEntry  

sleTemperatureIndex 1.3.6.1.4.1.6296.101.2.6.1.1.1
A unique value, greater than zero, for each module. It is recommended that values are assigned contiguously starting from 1.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

sleTemperatureState 1.3.6.1.4.1.6296.101.2.6.1.1.2
Temperature status information
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER failure(0), ok(1), others(2)  

sleTemperatureValue 1.3.6.1.4.1.6296.101.2.6.1.1.3
The value of temperature sensor. (unit: C)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sleTemperatureHighThreshold 1.3.6.1.4.1.6296.101.2.6.1.1.4
The High threshold of temperature.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sleTemperatureLowThreshold 1.3.6.1.4.1.6296.101.2.6.1.1.5
The Low threshold of temperature.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sleTemperatureWarnHighThreshold 1.3.6.1.4.1.6296.101.2.6.1.1.6
The High threshold of temperature.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -40..100  

sleTemperatureWarnLowThreshold 1.3.6.1.4.1.6296.101.2.6.1.1.7
The Low threshold of temperature.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -40..100  

sleTemperatureWarnDuration 1.3.6.1.4.1.6296.101.2.6.1.1.8
Duration-time units by the 5 sec. 0: Clear threshold.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..300  

sleTemperatureAlarmHighThreshold 1.3.6.1.4.1.6296.101.2.6.1.1.9
The High threshold of temperature.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -40..100  

sleTemperatureAlarmLowThreshold 1.3.6.1.4.1.6296.101.2.6.1.1.10
The Low threshold of temperature.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -40..100  

sleTemperatureAlarmDuration 1.3.6.1.4.1.6296.101.2.6.1.1.11
Duration-time units by the 5 sec. 0: Clear threshold.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..300  

sleTemperatureControl 1.3.6.1.4.1.6296.101.2.6.2
OBJECT IDENTIFIER    

sleTemperatureControlRequest 1.3.6.1.4.1.6296.101.2.6.2.1
set an administrative state of FAN module
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER setTempThreshold(1), setTempAlarmThreshold(2), setTempWarnThreshold(3)  

sleTemperatureControlStatus 1.3.6.1.4.1.6296.101.2.6.2.2
Description.
Status: current Access: read-only
OBJECT-TYPE    
  SleControlStatusType  

sleTemperatureControlTimer 1.3.6.1.4.1.6296.101.2.6.2.3
Description.
Status: current Access: read-write
OBJECT-TYPE    
  Gauge32  

sleTemperatureControlTimeStamp 1.3.6.1.4.1.6296.101.2.6.2.4
Description.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

sleTemperatureControlReqResult 1.3.6.1.4.1.6296.101.2.6.2.5
Description.
Status: current Access: read-only
OBJECT-TYPE    
  SleControlRequestResultType  

sleTemperatureControlIndex 1.3.6.1.4.1.6296.101.2.6.2.6
The Temperature index
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

sleTemperatureControlHighThreshold 1.3.6.1.4.1.6296.101.2.6.2.7
The High threshold of temperature.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

sleTemperatureControlLowThreshold 1.3.6.1.4.1.6296.101.2.6.2.8
The Low threshold of temperature.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

sleTemperatureControlDuration 1.3.6.1.4.1.6296.101.2.6.2.9
Duration-time units by the 5 sec. 0: Clear threshold.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..300  

sleTemperatureNotification 1.3.6.1.4.1.6296.101.2.6.3
OBJECT IDENTIFIER    

sleTemperatureThresholdChanged 1.3.6.1.4.1.6296.101.2.6.3.1
Description.
Status: current Access: read-write
NOTIFICATION-TYPE    

sleBattery 1.3.6.1.4.1.6296.101.2.7
OBJECT IDENTIFIER    

sleBatteryTable 1.3.6.1.4.1.6296.101.2.7.1
Description.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SleBatteryEntry

sleBatteryEntry 1.3.6.1.4.1.6296.101.2.7.1.1
Description.
Status: current Access: not-accessible
OBJECT-TYPE    
  SleBatteryEntry  

sleBatteryIndex 1.3.6.1.4.1.6296.101.2.7.1.1.1
The index of battery charger.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..256  

sleOperationPowerType 1.3.6.1.4.1.6296.101.2.7.1.1.2
Power Type.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER ac(0), rbu(1)  

sleOperationPowerInfo 1.3.6.1.4.1.6296.101.2.7.1.1.3
Operation Power Info.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

slePSUACPowerState 1.3.6.1.4.1.6296.101.2.7.1.1.4
Power State.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER ok(0), fault(1)  

slePSUTemperture 1.3.6.1.4.1.6296.101.2.7.1.1.5
Temperture.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slePSUTempThreshold 1.3.6.1.4.1.6296.101.2.7.1.1.6
Temperture Threshold.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

slePSUOutVoltage 1.3.6.1.4.1.6296.101.2.7.1.1.7
Voltage.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

slePSUOverTemp 1.3.6.1.4.1.6296.101.2.7.1.1.8
Description.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(0), over(1)  

slePSUFirmwareVer 1.3.6.1.4.1.6296.101.2.7.1.1.9
The firmware version of battery charger for communication to system.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sleRBUEquipState 1.3.6.1.4.1.6296.101.2.7.1.1.10
Equipment State.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER equipped(0), empty(1)  

sleRBUModeStaus 1.3.6.1.4.1.6296.101.2.7.1.1.11
Description.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleRBUTemperature1 1.3.6.1.4.1.6296.101.2.7.1.1.12
Description.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sleRBUTemperature2 1.3.6.1.4.1.6296.101.2.7.1.1.13
.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sleRBUTempLowThreshold 1.3.6.1.4.1.6296.101.2.7.1.1.14
RBU Low Temperature Threshold.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sleRBUOutVoltage 1.3.6.1.4.1.6296.101.2.7.1.1.15
RBU Out Voltage.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleRBUChargeCurrent 1.3.6.1.4.1.6296.101.2.7.1.1.16
Current Charge.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sleRBURemainCapacity 1.3.6.1.4.1.6296.101.2.7.1.1.17
Remain Capacity.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sleRBUOverTemp 1.3.6.1.4.1.6296.101.2.7.1.1.18
The state of Temperature over.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(0), over(1), under(2)  

sleBatteryLow 1.3.6.1.4.1.6296.101.2.7.1.1.19
Battery state.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(0), low(1), notAvailable(2)  

sleRBUTempHighThreshold 1.3.6.1.4.1.6296.101.2.7.1.1.20
RBU High Temperature Threshold.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sleRBUBTStatus 1.3.6.1.4.1.6296.101.2.7.1.1.21
Description.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

sleRBUBTThreshold 1.3.6.1.4.1.6296.101.2.7.1.1.22
Description.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sleRBURechargeVoltage 1.3.6.1.4.1.6296.101.2.7.1.1.23
Description.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sleBatteryCellStatus 1.3.6.1.4.1.6296.101.2.7.1.1.24
Description.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), failure(2)  

sleBPSUACHardwareVer 1.3.6.1.4.1.6296.101.2.7.1.1.25
Description.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sleBatteryControl 1.3.6.1.4.1.6296.101.2.7.2
OBJECT IDENTIFIER    

sleBatteryControlRequest 1.3.6.1.4.1.6296.101.2.7.2.1
Description.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER setBatteryForceCharge(1), setBatteryChargingStart(2), setBatteryForceChargeNonStop(3), setBatteryBootingTimeStatus(4), setBatteryBootingTime(5), setBatteryRechargeVoltage(6), setPsuAcTemperature(7), setBatteryTemperature(8)  

sleBatteryControlStatus 1.3.6.1.4.1.6296.101.2.7.2.2
Description.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

sleBatteryControlTimer 1.3.6.1.4.1.6296.101.2.7.2.3
Description.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

sleBatteryControlTimeStamp 1.3.6.1.4.1.6296.101.2.7.2.4
Description.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

sleBatteryControlReqResult 1.3.6.1.4.1.6296.101.2.7.2.5
Description.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

sleBatteryControlRBUBTStatus 1.3.6.1.4.1.6296.101.2.7.2.6
Description.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

sleBatteryControlRBUBTThreshold 1.3.6.1.4.1.6296.101.2.7.2.7
Description.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

sleBatteryControlRBURechargeVoltage 1.3.6.1.4.1.6296.101.2.7.2.8
Description.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

sleBatteryControlTemperThresh1 1.3.6.1.4.1.6296.101.2.7.2.9
Description.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

sleBatteryControlTemperThresh2 1.3.6.1.4.1.6296.101.2.7.2.10
Description.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

sleBatteryNotification 1.3.6.1.4.1.6296.101.2.7.3
OBJECT IDENTIFIER    

sleBatteryForceChargeChanged 1.3.6.1.4.1.6296.101.2.7.3.1
Description.
Status: current Access: read-write
NOTIFICATION-TYPE    

sleBatteryChargingStartChanged 1.3.6.1.4.1.6296.101.2.7.3.2
Description.
Status: current Access: read-write
NOTIFICATION-TYPE    

sleBatteryForceChargeNonStopChanged 1.3.6.1.4.1.6296.101.2.7.3.3
Description.
Status: current Access: read-write
NOTIFICATION-TYPE    

sleBatteryRBUBTStatusChanged 1.3.6.1.4.1.6296.101.2.7.3.4
Description.
Status: current Access: read-write
NOTIFICATION-TYPE    

sleBatteryRBUBTThresholdChanged 1.3.6.1.4.1.6296.101.2.7.3.5
Description.
Status: current Access: read-write
NOTIFICATION-TYPE    

sleBatteryRBURechargeVoltageChanged 1.3.6.1.4.1.6296.101.2.7.3.6
Description.
Status: current Access: read-write
NOTIFICATION-TYPE    

sleBatteryPsuAcTemperThreshChanged 1.3.6.1.4.1.6296.101.2.7.3.7
Description.
Status: current Access: read-write
NOTIFICATION-TYPE    

sleBatteryRBUTemperThreshChanged 1.3.6.1.4.1.6296.101.2.7.3.8
Description.
Status: current Access: read-write
NOTIFICATION-TYPE    

sleBatteryBackupTable 1.3.6.1.4.1.6296.101.2.7.4
Description.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SleBatteryBackupEntry

sleBatteryBackupEntry 1.3.6.1.4.1.6296.101.2.7.4.1
Description.
Status: current Access: not-accessible
OBJECT-TYPE    
  SleBatteryBackupEntry  

sleBatteryBackupFile 1.3.6.1.4.1.6296.101.2.7.4.1.1
Description.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1..64)  

sleBatteryBackupControl 1.3.6.1.4.1.6296.101.2.7.5
OBJECT IDENTIFIER    

sleBatteryBackupControlRequest 1.3.6.1.4.1.6296.101.2.7.5.1
Description.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER setBatteryBackupProfile(1), setBatteryUpgrade(2), clearBatteryBackupTable(3)  

sleBatteryBackupControlStatus 1.3.6.1.4.1.6296.101.2.7.5.2
Description.
Status: current Access: read-only
OBJECT-TYPE    
  SleControlStatusType  

sleBatteryBackupControlTimer 1.3.6.1.4.1.6296.101.2.7.5.3
Description.
Status: current Access: read-write
OBJECT-TYPE    
  Gauge32  

sleBatteryBackupControlTimeStamp 1.3.6.1.4.1.6296.101.2.7.5.4
Description.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

sleBatteryBackupControlReqResult 1.3.6.1.4.1.6296.101.2.7.5.5
Description.
Status: current Access: read-only
OBJECT-TYPE    
  SleControlRequestResultType  

sleBatteryBackupControlServerIP 1.3.6.1.4.1.6296.101.2.7.5.6
Description.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

sleBatteryBackupControlUserID 1.3.6.1.4.1.6296.101.2.7.5.7
Description.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1..64)  

sleBatteryBackupControlPassword 1.3.6.1.4.1.6296.101.2.7.5.8
Description.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1..64)  

sleBatteryBackupControlFlag 1.3.6.1.4.1.6296.101.2.7.5.9
Description.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER download(1), upload(2)  

sleBatteryBackupControlLocalFile 1.3.6.1.4.1.6296.101.2.7.5.10
Description.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1..64)  

sleBatteryBackupControlRemoteFile 1.3.6.1.4.1.6296.101.2.7.5.11
Description.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1..64)  

sleBatterBackupNotification 1.3.6.1.4.1.6296.101.2.7.6
OBJECT IDENTIFIER    

sleBatteryBackupProfileChanged 1.3.6.1.4.1.6296.101.2.7.6.1
Description.
Status: current Access: read-write
NOTIFICATION-TYPE    

sleBatteryBackupUpgraded 1.3.6.1.4.1.6296.101.2.7.6.2
Description.
Status: current Access: read-write
NOTIFICATION-TYPE    

sleBatteryBackupTableCleared 1.3.6.1.4.1.6296.101.2.7.6.3
Description.
Status: current Access: read-write
NOTIFICATION-TYPE    

sleDoor 1.3.6.1.4.1.6296.101.2.8
OBJECT IDENTIFIER    

sleDoorInfo 1.3.6.1.4.1.6296.101.2.8.1
OBJECT IDENTIFIER    

sleDoorStatus 1.3.6.1.4.1.6296.101.2.8.1.1
Description.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER close(0), open(1)  

sleCpu 1.3.6.1.4.1.6296.101.2.9
OBJECT IDENTIFIER    

sleCpuInfo 1.3.6.1.4.1.6296.101.2.9.1
OBJECT IDENTIFIER    

sleCpuProcessor 1.3.6.1.4.1.6296.101.2.9.1.1
Description.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleCpuModel 1.3.6.1.4.1.6296.101.2.9.1.2
Description.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleCpuRevision 1.3.6.1.4.1.6296.101.2.9.1.3
Description.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleCpuBogomips 1.3.6.1.4.1.6296.101.2.9.1.4
Description.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleCpuManufacturer 1.3.6.1.4.1.6296.101.2.9.1.5
Description.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleCpuClock 1.3.6.1.4.1.6296.101.2.9.1.6
Description.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sleCpuBusClock 1.3.6.1.4.1.6296.101.2.9.1.7
Description.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sleClockModule 1.3.6.1.4.1.6296.101.2.10
OBJECT IDENTIFIER    

sleClockModuleTable 1.3.6.1.4.1.6296.101.2.10.1
Description.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SleClockModuleEntry

sleClockModuleEntry 1.3.6.1.4.1.6296.101.2.10.1.1
Description.
Status: current Access: not-accessible
OBJECT-TYPE    
  SleClockModuleEntry  

sleClockModuleIndex 1.3.6.1.4.1.6296.101.2.10.1.1.1
A unique value, greater than zero, for each module. It is recommended that values are assigned contiguously starting from 1.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

sleClockModuleBoardId 1.3.6.1.4.1.6296.101.2.10.1.1.2
Indication of the board identifier.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER sfuA(1), sfuB(2)  

sleClockModuleInstallStatus 1.3.6.1.4.1.6296.101.2.10.1.1.3
The install status of clock module.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER removed(0), installed(1)  

sleClockModuleInitStatus 1.3.6.1.4.1.6296.101.2.10.1.1.4
The initialization status of clock module.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER failure(0), ok(1)  

sleClockModuleOPMode 1.3.6.1.4.1.6296.101.2.10.1.1.5
The CM operating mode
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER freerun(1), holdover(2), locked(3), prelocked2(4), prelocked(5), lostphase(6), unknown(255)  

sleClockInfo 1.3.6.1.4.1.6296.101.2.10.2
OBJECT IDENTIFIER    

sleClockInfoInSrcType 1.3.6.1.4.1.6296.101.2.10.2.1
The clock input source type.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  INTEGER ntt(1), ntt2(2), e1(3), t1(4), unknown(255)  

sleClockInfoInSrcStatus 1.3.6.1.4.1.6296.101.2.10.2.2
The input source is Valid or Invalid.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  INTEGER true(1), false(2)  

sleClockInfoInSrcAISStatus 1.3.6.1.4.1.6296.101.2.10.2.3
The AIS is detected or not detected.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  INTEGER true(1), false(2)  

sleClockInfoInSrcLoSStatus 1.3.6.1.4.1.6296.101.2.10.2.4
The LoS is detected or not detected
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  INTEGER true(1), false(2)  

sleClockInfoInSrcLDSCStatus 1.3.6.1.4.1.6296.101.2.10.2.5
The Line Driver Short Circuit is detected or not detected
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  INTEGER true(1), false(2)  

sleClockInfoInSrcNtrClockType 1.3.6.1.4.1.6296.101.2.10.2.6
The ntr clock is changed.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  BITS bit64Khz(0), bit8Khz(1), bit04Khz(2)  

sleSlot 1.3.6.1.4.1.6296.101.2.11
OBJECT IDENTIFIER    

sleSlotSystemInfo 1.3.6.1.4.1.6296.101.2.11.1
OBJECT IDENTIFIER    

sleSlotSystemInfoTable 1.3.6.1.4.1.6296.101.2.11.1.1
Description.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SleSlotSystemInfoEntry

sleSlotSystemInfoEntry 1.3.6.1.4.1.6296.101.2.11.1.1.1
Description.
Status: current Access: not-accessible
OBJECT-TYPE    
  SleSlotSystemInfoEntry  

sleSlotSystemIndex 1.3.6.1.4.1.6296.101.2.11.1.1.1.1
The system slot index.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..8  

sleSlotSystemUptime 1.3.6.1.4.1.6296.101.2.11.1.1.1.2
The time since the network management portion of the system was last re-initialized.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

sleSlotSystemModelName 1.3.6.1.4.1.6296.101.2.11.1.1.1.3
The model name.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleSlotSystemSerialNumber 1.3.6.1.4.1.6296.101.2.11.1.1.1.4
The serial number
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleSlotSystemHWVersion 1.3.6.1.4.1.6296.101.2.11.1.1.1.5
The H/W version.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleSlotSystemBLVersion 1.3.6.1.4.1.6296.101.2.11.1.1.1.6
The boot loader's S/W version.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleSlotSystemSWCompatibility 1.3.6.1.4.1.6296.101.2.11.1.1.1.7
The system compatibility.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleSlotSystemOSVersion 1.3.6.1.4.1.6296.101.2.11.1.1.1.8
The version information of current os.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleSlotSystemMacAddress 1.3.6.1.4.1.6296.101.2.11.1.1.1.9
The system's MAC address.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleSlotSystemCPULoadAll 1.3.6.1.4.1.6296.101.2.11.1.1.1.10
The CPU all load for 5/60/600 second. (unit: 0.01%)
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleSlotSystemCPULoadInterrupt 1.3.6.1.4.1.6296.101.2.11.1.1.1.11
The CPU interrupt load for 5/60/600 second. (unit: 0.01%)
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleSlotSystemMemoryTotal 1.3.6.1.4.1.6296.101.2.11.1.1.1.12
The total memory size (unit: kb)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

sleSlotSystemMemoryFree 1.3.6.1.4.1.6296.101.2.11.1.1.1.13
The freed memory size (unit: kb)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

sleSlotSystemMemoryShared 1.3.6.1.4.1.6296.101.2.11.1.1.1.14
The shared memory size (unit: kb)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

sleSlotSystemMemoryBuffers 1.3.6.1.4.1.6296.101.2.11.1.1.1.15
The buffer size (unit: kb)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

sleSlotSystemMemoryCached 1.3.6.1.4.1.6296.101.2.11.1.1.1.16
The cached memory size (unit: kb)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

sleSlotSystemMemorySwapTotal 1.3.6.1.4.1.6296.101.2.11.1.1.1.17
The total swap memory size (unit: kb)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

sleSlotSystemMemorySwapFree 1.3.6.1.4.1.6296.101.2.11.1.1.1.18
The freed swap memory size (unit: kb)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

sleSlotSystemBootReason 1.3.6.1.4.1.6296.101.2.11.1.1.1.19
The system slot boot reason.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER powerBoot(1), powerBootByLocal(2), hwResetBySW(3), hardWdogByLocal(4), hwRebootByMate(5), hwRebootBySwitchover(6), swReboot(10), swRebootByLocal(11), swRebootBySFU(12), swRebootBySwitchover(13), swRebootByPanic(14), watchdog(20), watchdogByLocal(21), swWatchdog(30), swWatchdogByCpuOver(31), swWatchdogByMemoryLow(32), error(255)  

sleSlotSystemBootTime 1.3.6.1.4.1.6296.101.2.11.1.1.1.20
The system slot boot time. The time since the Epoch (00:00:00 UTC, January 1, 1970), measured in seconds.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

sleSlotSystemVoltage 1.3.6.1.4.1.6296.101.2.11.1.1.1.21
The system slot voltage.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

sleSlotSystemPowerLevelStatus 1.3.6.1.4.1.6296.101.2.11.1.1.1.22
PCB Power level status.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER good(1), bad(2)  

sleSlotSystemInfoLEDStatus 1.3.6.1.4.1.6296.101.2.11.1.1.1.23
The LED status of each slot.
Status: current Access: read-only
OBJECT-TYPE    
  BITS pwr(0), run(1), critical(2), major(3), minor(4), error(5)  

sleSlotSystemInfoPackageVersion 1.3.6.1.4.1.6296.101.2.11.1.1.1.24
The applied package revision.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleSlotSystemInfoManufacturer 1.3.6.1.4.1.6296.101.2.11.1.1.1.25
Ths manufacturer name and country.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleSlotSystemInfoManufactureDate 1.3.6.1.4.1.6296.101.2.11.1.1.1.26
Ths manufacture date.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleSlotSystemCPULoadHighThreshold 1.3.6.1.4.1.6296.101.2.11.1.1.1.27
The high threshold of CPU load (70:default)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sleSlotSystemCPULoadHighThresholdTimer 1.3.6.1.4.1.6296.101.2.11.1.1.1.28
The high threshold timer of CPU load (sec) (60:default)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER timerInverval5(1), timerInverval60(2), timerInverval600(3)  

sleSlotSystemCPULoadLowThreshold 1.3.6.1.4.1.6296.101.2.11.1.1.1.29
The low threshold of CPU load (30:default)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sleSlotSystemCPULoadLowThresholdTimer 1.3.6.1.4.1.6296.101.2.11.1.1.1.30
The low threshold timer of CPU load (sec) (60:default)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER timerInverval5(1), timerInverval60(2), timerInverval600(3)  

sleSlotSystemCPULoadCurrent 1.3.6.1.4.1.6296.101.2.11.1.1.1.31
The CPU load currnet value (only used for trap)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sleSlotSystemCPUOverallStatus 1.3.6.1.4.1.6296.101.2.11.1.1.1.32
The CPU Overall status for SFU & IU
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER good(1), bad(2)  

sleSlotSystemTemperOverallStatus 1.3.6.1.4.1.6296.101.2.11.1.1.1.33
The Temperature Overall status for SFU & IU
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER good(1), bad(2)  

sleSlotSystemControl 1.3.6.1.4.1.6296.101.2.11.1.2
OBJECT IDENTIFIER    

sleSlotSystemControlRequest 1.3.6.1.4.1.6296.101.2.11.1.2.1
The request of a user command
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER setSlotRestart(1), setSlotCpuloadThreshold(2), delSlotCpuloadThreshold(3)  

sleSlotSystemControlStatus 1.3.6.1.4.1.6296.101.2.11.1.2.2
The status of user command
Status: current Access: read-only
OBJECT-TYPE    
  SleControlStatusType  

sleSlotSystemControlTimer 1.3.6.1.4.1.6296.101.2.11.1.2.3
The maximum time for the manager for a long running user command
Status: current Access: read-write
OBJECT-TYPE    
  Gauge32  

sleSlotSystemControlTimeStamp 1.3.6.1.4.1.6296.101.2.11.1.2.4
The time stamp of the last command(end of command)
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

sleSlotSystemControlReqResult 1.3.6.1.4.1.6296.101.2.11.1.2.5
The result of the last user command
Status: current Access: read-only
OBJECT-TYPE    
  SleControlRequestResultType  

sleSlotSystemControlSlotIndex 1.3.6.1.4.1.6296.101.2.11.1.2.6
The system slot index.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

sleSlotSystemControlCPULoadHighThreshold 1.3.6.1.4.1.6296.101.2.11.1.2.7
The high threshold of CPU load (70:default)
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 21..100  

sleSlotSystemControlCPULoadHighThresholdTimer 1.3.6.1.4.1.6296.101.2.11.1.2.8
The high threshold timer of CPU load (sec) (60:default)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER timerInverval5(1), timerInverval60(2), timerInverval600(3)  

sleSlotSystemControlCPULoadLowThreshold 1.3.6.1.4.1.6296.101.2.11.1.2.9
The low threshold of CPU load (30:default)
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 20..100  

sleSlotSystemControlCPULoadLowThresholdTimer 1.3.6.1.4.1.6296.101.2.11.1.2.10
The low threshold timer of CPU load (sec) (60:default)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER timerInverval5(1), timerInverval60(2), timerInverval600(3)  

sleSlotSystemNotification 1.3.6.1.4.1.6296.101.2.11.1.3
OBJECT IDENTIFIER    

sleSlotSystemRestart 1.3.6.1.4.1.6296.101.2.11.1.3.1
Description.
Status: current Access: read-write
NOTIFICATION-TYPE    

sleSlotSystemCPULoadChagned 1.3.6.1.4.1.6296.101.2.11.1.3.2
setSlotCpuloadThreshold
Status: current Access: read-write
NOTIFICATION-TYPE    

sleSlotSystemCPULoadDeleted 1.3.6.1.4.1.6296.101.2.11.1.3.3
delSlotCpuloadThreshold
Status: current Access: read-write
NOTIFICATION-TYPE    

sleSlotStatusInfo 1.3.6.1.4.1.6296.101.2.11.2
OBJECT IDENTIFIER    

sleSlotStatusInfoTable 1.3.6.1.4.1.6296.101.2.11.2.1
Description.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SleSlotStatusInfoEntry

sleSlotStatusInfoEntry 1.3.6.1.4.1.6296.101.2.11.2.1.1
Description.
Status: current Access: not-accessible
OBJECT-TYPE    
  SleSlotStatusInfoEntry  

sleSlotStatusPlan 1.3.6.1.4.1.6296.101.2.11.2.1.1.1
Planning status of slot.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notPlanned(1), planned(2)  

sleSlotStatusPlanCardType 1.3.6.1.4.1.6296.101.2.11.2.1.1.2
Planning card type status of slot.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), siuGE12(2), siuEPON12(3), siuGPON4(4), niuGE12(5), sfu(6), v5548gGE12(7), siuGPON4r(8), niuGE8(9), siuGE4(10), niu10GPlus(11), iu10GE(12), iuGE6(13), iuGE4(14), siuTDM(15), siuGE24(16), siuFE48(17), niu10GE2(18), siu10GE48(19), siuGE10(20), niu10Ge2Plus(21), iuGT4(22), iuGT6(23), iuTDM6(24), siuGE6(25), siuGE8(26), siuGT6(27), niuGE2(28), niuGE4(29), iuGEPON4(30), iu10GE8(31), iuGEPON8(32), iu10GEPON8(33), iuGE8(34), siu10GEPON8(35), niu10GE4(36), sfu10GE4(37), siuGPON16(38), iu10GE4(39), siuGT24(40), iu10GE2(41), cwdm(42), iuGT8(43)  

sleSlotStatusCurrentInstall 1.3.6.1.4.1.6296.101.2.11.2.1.1.3
Currently installation status of slot.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notInstalled(1), installed(2), failed(3)  

sleSlotStatusCurrentInstallCardType 1.3.6.1.4.1.6296.101.2.11.2.1.1.4
Currently installation card type status of slot.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), siuGE12(2), siuEPON12(3), siuGPON4(4), niuGE12(5), sfu(6), v5548gGE12(7), siuGPON4r(8), niuGE8(9), siuGE4(10), niu10GPlus(11), iuGE10(12), iuGE6(13), iuGE4(14), siuTDM(15), siuGE24(16), siuFE48(17), niu10GE2(18), siu10GE48(19), siuGE10(20), niu10Ge2Plus(21), iuGT4(22), iuGT6(23), iuTDM6(24), siuGE6(25), siuGE8(26), siuGT6(27), niuGE2(28), niuGE4(29), iuGEPON4(30), iu10GE8(31), iuGEPON8(32), iu10GEPON8(33), iuGE8(34), siu10GEPON8(35), niu10GE4(36), sfu10GE4(37), siuGPON16(38), iu10GE4(39), siuGT24(40), iu10GE2(41), cwdm(42), iuGT8(43)  

sleSlotStatusCardOperation 1.3.6.1.4.1.6296.101.2.11.2.1.1.5
Currently operation status of slot.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER disable(1), init(2), enable(3), enableActive(4), enableStandby(5)  

sleSlotStatusLock 1.3.6.1.4.1.6296.101.2.11.2.1.1.6
Lock status of slot.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unlocked(1), locked(2)  

sleSlotStatusUpgradeMode 1.3.6.1.4.1.6296.101.2.11.2.1.1.7
Upgrade mode status of slot.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER manual(1), auto(2)  

sleSlotStatusActionEvent 1.3.6.1.4.1.6296.101.2.11.2.1.1.8
Event of slot. (accessible-for-notify)
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  INTEGER uninstallAction(1), installAction(2), noPlanningAction(3), planningAction(4), lockAction(5), unlockAction(6), matchedEvent(7), unMatchedEvent(8), bootEndEvent(9), configEndEvent(10), configFailEvent(11)  

sleSlotStatusState 1.3.6.1.4.1.6296.101.2.11.2.1.1.9
Status of slot. (accessible-for-notify)
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  INTEGER default(1), planningWait(2), installWait(3), operationReady(4), actionBootReady(5), actionConfig(6), actionEnableReady(7), actionEnable(8), actionEnableLock(9), actionDisable(10)  

sleSlotStatusPower 1.3.6.1.4.1.6296.101.2.11.2.1.1.10
Currently power status of slot.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER up(1), down(2)  

sleSlotStatusSerialNumber 1.3.6.1.4.1.6296.101.2.11.2.1.1.11
The serial number
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleSlotStatusHealthState 1.3.6.1.4.1.6296.101.2.11.2.1.1.12
The slot health status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER well(0), warning(1), timeout(2)  

sleslotStatusOverallState 1.3.6.1.4.1.6296.101.2.11.2.1.1.13
The slot overrall status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER good(0), bad(1)  

sleslotStatusSyncState 1.3.6.1.4.1.6296.101.2.11.2.1.1.14
The slot sync status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(0), disable(1), process(2), done(3)  

sleSlotStatusControl 1.3.6.1.4.1.6296.101.2.11.2.2
OBJECT IDENTIFIER    

sleSlotStatusControlRequest 1.3.6.1.4.1.6296.101.2.11.2.2.1
The request of a user command
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER setSlotLock(1), setSlotUnlock(2), setSlotPlanning(3), setSlotNoplanning(4), setSlotUpgradeMode(5), setSlotPowerUp(6), setSlotPowerDown(7), setSlotPowerReset(8)  

sleSlotStatusControlStatus 1.3.6.1.4.1.6296.101.2.11.2.2.2
The status of user command
Status: current Access: read-only
OBJECT-TYPE    
  SleControlStatusType  

sleSlotStatusControlTimer 1.3.6.1.4.1.6296.101.2.11.2.2.3
The maximum time for the manager for a long running user command
Status: current Access: read-write
OBJECT-TYPE    
  Gauge32  

sleSlotStatusControlTimeStamp 1.3.6.1.4.1.6296.101.2.11.2.2.4
The time stamp of the last command(end of command)
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

sleSlotStatusControlReqResult 1.3.6.1.4.1.6296.101.2.11.2.2.5
The result of the last user command
Status: current Access: read-only
OBJECT-TYPE    
  SleControlRequestResultType  

sleSlotStatusControlSlotIndex 1.3.6.1.4.1.6296.101.2.11.2.2.6
The system slot index. 255 is means all slot.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

sleSlotStatusControlPlanCardType 1.3.6.1.4.1.6296.101.2.11.2.2.7
Planning card type status of slot.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), siuGE12(2), siuEPON12(3), siuGPON4(4), niuGE12(5), sfu(6), v5548gGE12(7), siuGPON4r(8), niuGE8(9), siuGE4(10), niu10GPlus(11), iuGE10(12), iuGE6(13), iuGE4(14), siuTDM(15), siuGE24(16), siuFE48(17), niu10GE2(18), siu10GE48(19), siuGE10(20), niu10Ge2Plus(21), iuGT4(22), iuGT6(23), iuTDM6(24), siuGE6(25), siuGE8(26), siuGT6(27), niuGE2(28), niuGE4(29), iuGEPON4(30), iu10GE8(31), iuGEPON8(32), iu10GEPON8(33), iuGE8(34), siu10GEPON8(35), niu10GE4(36), sfu10GE4(37), siuGPON16(38), iu10GE4(39), siuGT24(40), iu10GE2(41), cwdm(42), iuGT8(43)  

sleSlotStatusControlUpgradeMode 1.3.6.1.4.1.6296.101.2.11.2.2.8
Upgrade mode status of slot.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER manual(1), auto(2), autoUpgradeManualReset(3)  

sleSlotStatusNotification 1.3.6.1.4.1.6296.101.2.11.2.3
OBJECT IDENTIFIER    

sleSlotStatusLocked 1.3.6.1.4.1.6296.101.2.11.2.3.1
Description.
Status: current Access: read-write
NOTIFICATION-TYPE    

sleSlotStatusUnlocked 1.3.6.1.4.1.6296.101.2.11.2.3.2
Description.
Status: current Access: read-write
NOTIFICATION-TYPE    

sleSlotStatusPlanning 1.3.6.1.4.1.6296.101.2.11.2.3.3
Description.
Status: current Access: read-write
NOTIFICATION-TYPE    

sleSlotStatusNoPlanning 1.3.6.1.4.1.6296.101.2.11.2.3.4
Description.
Status: current Access: read-write
NOTIFICATION-TYPE    

sleSlotStatusUpgradeModeChanged 1.3.6.1.4.1.6296.101.2.11.2.3.5
Description.
Status: current Access: read-write
NOTIFICATION-TYPE    

sleSlotStatusPowerUp 1.3.6.1.4.1.6296.101.2.11.2.3.6
Description.
Status: current Access: read-write
NOTIFICATION-TYPE    

sleSlotStatusPowerDown 1.3.6.1.4.1.6296.101.2.11.2.3.7
Description.
Status: current Access: read-write
NOTIFICATION-TYPE    

sleSlotStatusPowerReset 1.3.6.1.4.1.6296.101.2.11.2.3.8
Description.
Status: current Access: read-write
NOTIFICATION-TYPE    

sleSlotNosInfo 1.3.6.1.4.1.6296.101.2.11.3
OBJECT IDENTIFIER    

sleSlotNosInfoTable 1.3.6.1.4.1.6296.101.2.11.3.1
Description.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SleSlotNosInfoEntry

sleSlotNosInfoEntry 1.3.6.1.4.1.6296.101.2.11.3.1.1
Description.
Status: current Access: not-accessible
OBJECT-TYPE    
  SleSlotNosInfoEntry  

sleSlotNosVersion 1.3.6.1.4.1.6296.101.2.11.3.1.1.1
NOS version of slot.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleSlotNosRevision 1.3.6.1.4.1.6296.101.2.11.3.1.1.2
NOS revision of slot.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleSlotNosSize 1.3.6.1.4.1.6296.101.2.11.3.1.1.3
NOS size of slot.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

sleSlotNosUpgradeStatus 1.3.6.1.4.1.6296.101.2.11.3.1.1.4
NOS upgrade status of slot.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER upgradeIdle(1), upgradeStart(2), upgradeDone(3), upgradeFail(4)  

sleSlotNosStbVersion 1.3.6.1.4.1.6296.101.2.11.3.1.1.5
Stand by NOS version of slot
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleSlotNosStbRevision 1.3.6.1.4.1.6296.101.2.11.3.1.1.6
Stand by NOS revision of slot.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleSlotNosStbSize 1.3.6.1.4.1.6296.101.2.11.3.1.1.7
Stand by NOS size of slot.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

sleSlotNosControl 1.3.6.1.4.1.6296.101.2.11.3.2
OBJECT IDENTIFIER    

sleSlotNosControlRequest 1.3.6.1.4.1.6296.101.2.11.3.2.1
The request of a user command
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER setSlotUpgarde(1), downloadSlotNos(2), upgradeSlotBootloader(3)  

sleSlotNosControlStatus 1.3.6.1.4.1.6296.101.2.11.3.2.2
The status of user command
Status: current Access: read-only
OBJECT-TYPE    
  SleControlStatusType  

sleSlotNosControlTimer 1.3.6.1.4.1.6296.101.2.11.3.2.3
The maximum time for the manager for a long running user command
Status: current Access: read-write
OBJECT-TYPE    
  Gauge32  

sleSlotNosControlTimeStamp 1.3.6.1.4.1.6296.101.2.11.3.2.4
The time stamp of the last command(end of command)
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

sleSlotNosControlReqResult 1.3.6.1.4.1.6296.101.2.11.3.2.5
The result of the last user command
Status: current Access: read-only
OBJECT-TYPE    
  SleControlRequestResultType  

sleSlotNosControlSlotIndex 1.3.6.1.4.1.6296.101.2.11.3.2.6
The system slot index.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

sleSlotNosControlUpDownMethod 1.3.6.1.4.1.6296.101.2.11.3.2.7
1: using FTP 2: using TFTP
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ftp(1), tftp(2)  

sleSlotNosControlUpDownFlag 1.3.6.1.4.1.6296.101.2.11.3.2.8
1. Uploading slot nos to the remote-host. 2. Downloading slot nos from the remote-host.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER upload(1), download(2)  

sleSlotNosControlServerAddress 1.3.6.1.4.1.6296.101.2.11.3.2.9
The remote-host's IP address.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

sleSlotNosControlUserID 1.3.6.1.4.1.6296.101.2.11.3.2.10
Account-name.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

sleSlotNosControlPassword 1.3.6.1.4.1.6296.101.2.11.3.2.11
Account-password.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

sleSlotNosControlFileName 1.3.6.1.4.1.6296.101.2.11.3.2.12
Slot nos file name.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

sleSlotNosNotification 1.3.6.1.4.1.6296.101.2.11.3.3
OBJECT IDENTIFIER    

sleSlotNosUpgrade 1.3.6.1.4.1.6296.101.2.11.3.3.1
Description.
Status: current Access: read-write
NOTIFICATION-TYPE    

sleSlotNosDownload 1.3.6.1.4.1.6296.101.2.11.3.3.2
Description.
Status: current Access: read-write
NOTIFICATION-TYPE    

sleSlotNosBootloaderUpgrade 1.3.6.1.4.1.6296.101.2.11.3.3.3
Description.
Status: current Access: read-write
NOTIFICATION-TYPE    

sleSlotReleasedIUNosInfo 1.3.6.1.4.1.6296.101.2.11.4
OBJECT IDENTIFIER    

sleSlotReleasedNIUNosVersion 1.3.6.1.4.1.6296.101.2.11.4.1
Released NIU NOS image version on SFU.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleSlotReleasedNIUNosRevision 1.3.6.1.4.1.6296.101.2.11.4.2
Released NIU NOS image revision on SFU.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleSlotReleasedNIUNosSize 1.3.6.1.4.1.6296.101.2.11.4.3
Released NIU NOS image size on SFU.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

sleSlotReleasedGPIUNosVersion 1.3.6.1.4.1.6296.101.2.11.4.4
Released GPIU NOS image version on SFU.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleSlotReleasedGPIUNosRevision 1.3.6.1.4.1.6296.101.2.11.4.5
Released GPIU NOS image revision on SFU.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleSlotReleasedGPIUNosSize 1.3.6.1.4.1.6296.101.2.11.4.6
Released GPIU NOS image size on SFU.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

sleSlotReleasedSIUNosVersion 1.3.6.1.4.1.6296.101.2.11.4.7
Released SIU NOS image version on SFU.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleSlotReleasedSIUNosRevision 1.3.6.1.4.1.6296.101.2.11.4.8
Released SIU NOS image revision on SFU.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleSlotReleasedSIUNosSize 1.3.6.1.4.1.6296.101.2.11.4.9
Released SIU NOS image size on SFU.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sleSlotReleasedIU10GE8NosVersion 1.3.6.1.4.1.6296.101.2.11.4.10
Released IU_10GE8 NOS image version on SFU.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleSlotReleasedIU10GE8NosRevision 1.3.6.1.4.1.6296.101.2.11.4.11
Released IU_10GE8 NOS image revision on SFU.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleSlotReleasedIU10GE8NosSize 1.3.6.1.4.1.6296.101.2.11.4.12
Released IU_10GE8 NOS image size on SFU.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sleSlotReleasedIU10GEPON8NosVersion 1.3.6.1.4.1.6296.101.2.11.4.13
Released IU_10GEPON8 NOS image version on SFU.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleSlotReleasedIU10GEPON8NosRevision 1.3.6.1.4.1.6296.101.2.11.4.14
Released IU_10GEPON8 NOS image revision on SFU.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleSlotReleasedIU10GEPON8NosSize 1.3.6.1.4.1.6296.101.2.11.4.15
Released IU_10GEPON8 NOS image size on SFU.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sleSlotReleasedIUGEPON8NosVersion 1.3.6.1.4.1.6296.101.2.11.4.16
Released IU_GEPON8 NOS image version on SFU.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleSlotReleasedIUGEPON8NosRevision 1.3.6.1.4.1.6296.101.2.11.4.17
Released IU_GEPON8 NOS image revision on SFU
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleSlotReleasedIUGEPON8NosSize 1.3.6.1.4.1.6296.101.2.11.4.18
Released IU_GEPON8 NOS image size on SFU.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sleSlotPowerMon 1.3.6.1.4.1.6296.101.2.11.5
OBJECT IDENTIFIER    

sleSlotPowerMonTable 1.3.6.1.4.1.6296.101.2.11.5.1
The Power-Monitoring table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SleSlotPowerMonEntry

sleSlotPowerMonEntry 1.3.6.1.4.1.6296.101.2.11.5.1.1
The Power-Monitoring entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  SleSlotPowerMonEntry  

sleSlotPowerMonIndex 1.3.6.1.4.1.6296.101.2.11.5.1.1.1
The physical index of power-monitoring object.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

sleSlotPowerMonStatus 1.3.6.1.4.1.6296.101.2.11.5.1.1.2
The monitoring status of power-monitoring object.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), good(2), bad(3), over(4), under(5), overUnder(6)  

sleSlotPowerMonVoltage 1.3.6.1.4.1.6296.101.2.11.5.1.1.3
The voltage value of power-monitoring object. value 10000(1000v) indicate that FUSE.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

sleSlotAiu 1.3.6.1.4.1.6296.101.2.11.6
OBJECT IDENTIFIER    

sleSlotAiuRunStatus 1.3.6.1.4.1.6296.101.2.11.6.1
The slot AIU run status.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(0), on(1)  

sleSlotAiuAlarmStatus 1.3.6.1.4.1.6296.101.2.11.6.2
The slot AIU alarm status.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(0), on(1)  

sleSlotProtection 1.3.6.1.4.1.6296.101.2.11.7
OBJECT IDENTIFIER    

sleSlotProtectionBase 1.3.6.1.4.1.6296.101.2.11.7.1
OBJECT IDENTIFIER    

sleSlotProtectionInfo 1.3.6.1.4.1.6296.101.2.11.7.1.1
OBJECT IDENTIFIER    

sleSlotProtectionSystemStatus 1.3.6.1.4.1.6296.101.2.11.7.1.1.1
The system admin status(enable or disable) of overtemperature shutdown function.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

sleSlotProtectionSystemThreshold 1.3.6.1.4.1.6296.101.2.11.7.1.1.2
The system admin threshold of overtemperature shutdown function.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sleSlotProtectionIUPowerStatus 1.3.6.1.4.1.6296.101.2.11.7.1.1.3
The slot power shutdown status
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

sleSlotProtectionControl 1.3.6.1.4.1.6296.101.2.11.7.1.2
OBJECT IDENTIFIER    

sleSlotProtectionControlRequest 1.3.6.1.4.1.6296.101.2.11.7.1.2.1
The request of a user command
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER setSlotProtectionSystemStatus(1), setSlotProtectionSystemThresh(2), setslotProtectionIUPowerStatus(3)  

sleSlotProtectionControlStatus 1.3.6.1.4.1.6296.101.2.11.7.1.2.2
The status of user command
Status: current Access: read-only
OBJECT-TYPE    
  SleControlStatusType  

sleSlotProtectionControlTimer 1.3.6.1.4.1.6296.101.2.11.7.1.2.3
The maximum time for the manager for a long running user command
Status: current Access: read-write
OBJECT-TYPE    
  Gauge32  

sleSlotProtectionControlTimeStamp 1.3.6.1.4.1.6296.101.2.11.7.1.2.4
The time stamp of the last command(end of command)
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

sleSlotProtectionControlReqResult 1.3.6.1.4.1.6296.101.2.11.7.1.2.5
The result of the last user command
Status: current Access: read-only
OBJECT-TYPE    
  SleControlRequestResultType  

sleSlotProtectionControlSystemStatus 1.3.6.1.4.1.6296.101.2.11.7.1.2.6
The system admin status(enable or disable) of overtemperature shutdown function.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

sleSlotProtectionControlSystemThreshold 1.3.6.1.4.1.6296.101.2.11.7.1.2.7
The system admin threshold of overtemperature shutdown function.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

sleSlotProtectionControlIUPowerStatus 1.3.6.1.4.1.6296.101.2.11.7.1.2.8
The slot power shutdown status
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

sleSlotProtectionNotification 1.3.6.1.4.1.6296.101.2.11.7.1.3
OBJECT IDENTIFIER    

sleSlotProtectionSystemStatusChanged 1.3.6.1.4.1.6296.101.2.11.7.1.3.1
Description.
Status: current Access: read-write
NOTIFICATION-TYPE    

sleSlotProtectionSystemThreshChanged 1.3.6.1.4.1.6296.101.2.11.7.1.3.2
Description.
Status: current Access: read-write
NOTIFICATION-TYPE    

sleSlotProtectionIUPowerStatusChanged 1.3.6.1.4.1.6296.101.2.11.7.1.3.3
Description.
Status: current Access: read-write
NOTIFICATION-TYPE    

sleSlotProtectionIU 1.3.6.1.4.1.6296.101.2.11.7.2
OBJECT IDENTIFIER    

sleSlotProtectionIUTable 1.3.6.1.4.1.6296.101.2.11.7.2.1
Description.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SleSlotProtectionIUEntry

sleSlotProtectionIUEntry 1.3.6.1.4.1.6296.101.2.11.7.2.1.1
Description.
Status: current Access: not-accessible
OBJECT-TYPE    
  SleSlotProtectionIUEntry  

sleSlotProtectionIUTemperHighThresh 1.3.6.1.4.1.6296.101.2.11.7.2.1.1.1
The Slot temperature High-threshold of overtemperature alarm
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..65535  

sleSlotProtectionIUTemperLowThresh 1.3.6.1.4.1.6296.101.2.11.7.2.1.1.2
The Slot temperature Low-threshold of overtemperature alarm
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..65535  

sleSlotProtectionIUPowerThresh 1.3.6.1.4.1.6296.101.2.11.7.2.1.1.3
The Slot temperature threshold of overtemperature power shutdown.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..65535  

sleSlotProtectionIUTemper 1.3.6.1.4.1.6296.101.2.11.7.2.1.1.4
The Slot temperature.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..65535  

sleSlotProtectionIUTemper2 1.3.6.1.4.1.6296.101.2.11.7.2.1.1.5
The Slot temperature2.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..65535  

sleSlotProtectionIUControl 1.3.6.1.4.1.6296.101.2.11.7.2.2
OBJECT IDENTIFIER    

sleSlotProtectionIUControlRequest 1.3.6.1.4.1.6296.101.2.11.7.2.2.1
The request of a user command
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER setSlotTempThreshold(1), setSlotPowerThresh(2)  

sleSlotProtectionIUControlStatus 1.3.6.1.4.1.6296.101.2.11.7.2.2.2
The status of user command
Status: current Access: read-only
OBJECT-TYPE    
  SleControlStatusType  

sleSlotProtectionIUControlTimer 1.3.6.1.4.1.6296.101.2.11.7.2.2.3
The maximum time for the manager for a long running user command
Status: current Access: read-write
OBJECT-TYPE    
  Gauge32  

sleSlotProtectionIUControlTimeStamp 1.3.6.1.4.1.6296.101.2.11.7.2.2.4
The time stamp of the last command(end of command)
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

sleSlotProtectionIUControlReqResult 1.3.6.1.4.1.6296.101.2.11.7.2.2.5
The result of the last user command
Status: current Access: read-only
OBJECT-TYPE    
  SleControlRequestResultType  

sleSlotProtectionIUControlindex 1.3.6.1.4.1.6296.101.2.11.7.2.2.6
the slot index
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

sleSlotProtectionIUControlTemperHighThresh 1.3.6.1.4.1.6296.101.2.11.7.2.2.7
The Slot temperature High-threshold of overtemperature alarm
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

sleSlotProtectionIUControlTemperLowThresh 1.3.6.1.4.1.6296.101.2.11.7.2.2.8
The Slot temperature Low-threshold of overtemperature alarm
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

sleSlotProtectionIUControlPowerThresh 1.3.6.1.4.1.6296.101.2.11.7.2.2.9
The Slot temperature threshold of overtemperature power shutdown.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

sleSlotProtectionIUNotification 1.3.6.1.4.1.6296.101.2.11.7.2.3
OBJECT IDENTIFIER    

sleSlotProtectionIUTemperThreshChanged 1.3.6.1.4.1.6296.101.2.11.7.2.3.1
Description.
Status: current Access: read-write
NOTIFICATION-TYPE    

sleSlotProtectionIUPowerThreshChanged 1.3.6.1.4.1.6296.101.2.11.7.2.3.2
Description.
Status: current Access: read-write
NOTIFICATION-TYPE    

sleRF 1.3.6.1.4.1.6296.101.2.12
OBJECT IDENTIFIER    

sleRfBaseInfo 1.3.6.1.4.1.6296.101.2.12.1
OBJECT IDENTIFIER    

sleRfConnectStatus 1.3.6.1.4.1.6296.101.2.12.1.1
The RF connect status.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER connect(1), disconnect(2)  

sleRfPowerStatus 1.3.6.1.4.1.6296.101.2.12.1.2
The RF power status.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER poweroff(0), poweron(1)  

sleRfEthertype 1.3.6.1.4.1.6296.101.2.12.1.3
The RF ethertype.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleRfSrcAddress 1.3.6.1.4.1.6296.101.2.12.1.4
The RF source address.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleRfDesAddress 1.3.6.1.4.1.6296.101.2.12.1.5
The RF destination address.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleRfBaseControl 1.3.6.1.4.1.6296.101.2.12.2
OBJECT IDENTIFIER    

sleRfBaseControlRequest 1.3.6.1.4.1.6296.101.2.12.2.1
The request of a user command.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER setRfEthertype(1), resetRfEthertype(2)  

sleRfBaseControlStatus 1.3.6.1.4.1.6296.101.2.12.2.2
The status of user command.
Status: current Access: read-only
OBJECT-TYPE    
  SleControlStatusType  

sleRfBaseControlTimer 1.3.6.1.4.1.6296.101.2.12.2.3
The maximum time for the manager for a long running user command.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

sleRfBaseControlTimeStamp 1.3.6.1.4.1.6296.101.2.12.2.4
The time stamp of the last command(end of command).
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

sleRfBaseControlReqResult 1.3.6.1.4.1.6296.101.2.12.2.5
The result of user command.
Status: current Access: read-only
OBJECT-TYPE    
  SleControlRequestResultType  

sleRfBaseControlRfEthertype 1.3.6.1.4.1.6296.101.2.12.2.6
The Rf ethertype ,the format is 0xXXXX, default value is 0x8864.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

sleRfBaseNotification 1.3.6.1.4.1.6296.101.2.12.3
OBJECT IDENTIFIER    

sleRFBaseEthertypeChanged 1.3.6.1.4.1.6296.101.2.12.3.1
Description.
Status: current Access: read-write
NOTIFICATION-TYPE    

sleRFBaseEthertypeResetChanged 1.3.6.1.4.1.6296.101.2.12.3.2
Description.
Status: current Access: read-write
NOTIFICATION-TYPE    

sleRfPortTable 1.3.6.1.4.1.6296.101.2.12.4
Description.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SleRfPortEntry

sleRfPortEntry 1.3.6.1.4.1.6296.101.2.12.4.1
Description.
Status: current Access: not-accessible
OBJECT-TYPE    
  SleRfPortEntry  

sleRfPortIndex 1.3.6.1.4.1.6296.101.2.12.4.1.1
The RF port index.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..256  

sleRfPortAdminStatus 1.3.6.1.4.1.6296.101.2.12.4.1.2
The RF port adminStatus.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2), na(255)  

sleRfPortOperStatus 1.3.6.1.4.1.6296.101.2.12.4.1.3
The RF port operStatus.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2), na(255)  

sleRFPortControl 1.3.6.1.4.1.6296.101.2.12.5
OBJECT IDENTIFIER    

sleRfPortControlRequest 1.3.6.1.4.1.6296.101.2.12.5.1
The request of a user command.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER setRfPortStatus(1)  

sleRfPortControlStatus 1.3.6.1.4.1.6296.101.2.12.5.2
The status of user command.
Status: current Access: read-only
OBJECT-TYPE    
  SleControlStatusType  

sleRfPortControlTimer 1.3.6.1.4.1.6296.101.2.12.5.3
The maximum time for the manager for a long running user command.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

sleRfPortControlTimeStamp 1.3.6.1.4.1.6296.101.2.12.5.4
The time stamp of the last command(end of command).
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

sleRfPortControlReqResult 1.3.6.1.4.1.6296.101.2.12.5.5
The result of user command.
Status: current Access: read-only
OBJECT-TYPE    
  SleControlRequestResultType  

sleRfPortControlIndex 1.3.6.1.4.1.6296.101.2.12.5.6
The RF port index <1-8>.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..8  

sleRfPortControlAdminStatus 1.3.6.1.4.1.6296.101.2.12.5.7
The RF port adminStatus.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

sleRFPortNotification 1.3.6.1.4.1.6296.101.2.12.6
OBJECT IDENTIFIER    

sleRfPortStatusChanged 1.3.6.1.4.1.6296.101.2.12.6.1
Description.
Status: current Access: read-write
NOTIFICATION-TYPE    

sleEnvironmentMonitor 1.3.6.1.4.1.6296.101.2.13
OBJECT IDENTIFIER    

sleEMTable 1.3.6.1.4.1.6296.101.2.13.1
Description.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SleEMEntry

sleEMEntry 1.3.6.1.4.1.6296.101.2.13.1.1
Description.
Status: current Access: not-accessible
OBJECT-TYPE    
  SleEMEntry  

sleEMInputIndex 1.3.6.1.4.1.6296.101.2.13.1.1.1
The environment monitoring input index(1-4).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..4  

sleEMAlarmString 1.3.6.1.4.1.6296.101.2.13.1.1.2
The alarm string
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleEMAlarmSeverity 1.3.6.1.4.1.6296.101.2.13.1.1.3
The alarm severity.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(0), critical(1), major(2), minor(3), warning(4), intermediate(5)  

sleEMmode 1.3.6.1.4.1.6296.101.2.13.1.1.4
The environment monitoring mode.(default:normal-close)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normalClose(0), normalOpen(1)  

sleEMControl 1.3.6.1.4.1.6296.101.2.13.2
OBJECT IDENTIFIER    

sleEMControlRequest 1.3.6.1.4.1.6296.101.2.13.2.1
The request of a user command.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER setEM(1), delEM(2)  

sleEMControlStatus 1.3.6.1.4.1.6296.101.2.13.2.2
Description.
Status: current Access: read-only
OBJECT-TYPE    
  SleControlStatusType  

sleEMControlTimer 1.3.6.1.4.1.6296.101.2.13.2.3
The maximum time for the manager for a long running user command. Apply your setting.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

sleEMControlTimeStamp 1.3.6.1.4.1.6296.101.2.13.2.4
Description.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

sleEMControlReqResult 1.3.6.1.4.1.6296.101.2.13.2.5
Description.
Status: current Access: read-only
OBJECT-TYPE    
  SleControlRequestResultType  

sleEMControlInputIndex 1.3.6.1.4.1.6296.101.2.13.2.6
The environment monitoring input index(1-4).
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..4  

sleEMControlAlarmString 1.3.6.1.4.1.6296.101.2.13.2.7
The alarm string
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

sleEMControlAlarmSeverity 1.3.6.1.4.1.6296.101.2.13.2.8
The alarm severity.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(0), critical(1), major(2), minor(3), warning(4), intermediate(5)  

sleEMControlmode 1.3.6.1.4.1.6296.101.2.13.2.9
The environment monitoring mode.(default:normal-close)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER normalClose(0), normalOpen(1)  

sleEMNotification 1.3.6.1.4.1.6296.101.2.13.3
OBJECT IDENTIFIER    

sleEMChanged 1.3.6.1.4.1.6296.101.2.13.3.1
Description.
Status: current Access: read-write
NOTIFICATION-TYPE    

sleEMDeleted 1.3.6.1.4.1.6296.101.2.13.3.2
Description.
Status: current Access: read-write
NOTIFICATION-TYPE    

sleBypass 1.3.6.1.4.1.6296.101.2.14
OBJECT IDENTIFIER    

sleBypassBase 1.3.6.1.4.1.6296.101.2.14.1
OBJECT IDENTIFIER    

sleBypassBaseInfo 1.3.6.1.4.1.6296.101.2.14.1.1
OBJECT IDENTIFIER    

sleBypassMode 1.3.6.1.4.1.6296.101.2.14.1.1.1
optic bypass mode
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2), auto(3)  

sleBypassStatus 1.3.6.1.4.1.6296.101.2.14.1.1.2
optic bypass status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

sleBypassBaseControl 1.3.6.1.4.1.6296.101.2.14.1.2
OBJECT IDENTIFIER    

sleBypassBaseControlRequest 1.3.6.1.4.1.6296.101.2.14.1.2.1
Description.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER setBypassMode(1)  

sleBypassBaseControlStatus 1.3.6.1.4.1.6296.101.2.14.1.2.2
The status of user command.
Status: current Access: read-only
OBJECT-TYPE    
  SleControlStatusType  

sleBypassBaseControlTimer 1.3.6.1.4.1.6296.101.2.14.1.2.3
The maximum time for the manager for a long running user command.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

sleBypassBaseControlTimeStamp 1.3.6.1.4.1.6296.101.2.14.1.2.4
The time stamp of the last command(end of command).
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

sleBypassBaseControlReqResult 1.3.6.1.4.1.6296.101.2.14.1.2.5
The result of user command.
Status: current Access: read-only
OBJECT-TYPE    
  SleControlRequestResultType  

sleBypassBaseControlMode 1.3.6.1.4.1.6296.101.2.14.1.2.6
optic bypass mode
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2), auto(3)  

sleBypassBaseNotification 1.3.6.1.4.1.6296.101.2.14.1.3
OBJECT IDENTIFIER    

sleBypassModeChanged 1.3.6.1.4.1.6296.101.2.14.1.3.1
setBypassMode(1)
Status: current Access: read-write
NOTIFICATION-TYPE    

sleBypassOption 1.3.6.1.4.1.6296.101.2.14.2
OBJECT IDENTIFIER    

sleBypassOptionConnectivityTable 1.3.6.1.4.1.6296.101.2.14.2.1
The connectivity option of bypass
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SleBypassOptionConnectivityEntry

sleBypassOptionConnectivityEntry 1.3.6.1.4.1.6296.101.2.14.2.1.1
Description.
Status: current Access: not-accessible
OBJECT-TYPE    
  SleBypassOptionConnectivityEntry  

sleBypassOptionConnectivityAddress 1.3.6.1.4.1.6296.101.2.14.2.1.1.1
The target IP address of bypass health-checking
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

sleBypassOptionConnectivityPort 1.3.6.1.4.1.6296.101.2.14.2.1.1.2
The target port of bypass health-checking.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..65535  

sleBypassOptionConnectivityControl 1.3.6.1.4.1.6296.101.2.14.2.2
OBJECT IDENTIFIER    

sleBypassOptionConnectivityControlRequest 1.3.6.1.4.1.6296.101.2.14.2.2.1
setBypassConnectivity(1) : bypass-check-option connectivity (A.B.C.D) PORT unsetBypassConnectivity(2) : no bypass-check option connectivity
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER setBypassConnectivity(1), unsetBypassConnectivity(2)  

sleBypassOptionConnectivityControlStatus 1.3.6.1.4.1.6296.101.2.14.2.2.2
The status of user command.
Status: current Access: read-only
OBJECT-TYPE    
  SleControlStatusType  

sleBypassOptionConnectivityControlTimer 1.3.6.1.4.1.6296.101.2.14.2.2.3
The maximum time for the manager for a long running user command.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

sleBypassOptionConnectivityControlTimeStamp 1.3.6.1.4.1.6296.101.2.14.2.2.4
The time stamp of the last command(end of command).
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

sleBypassOptionConnectivityControlReqResult 1.3.6.1.4.1.6296.101.2.14.2.2.5
The result of user command.
Status: current Access: read-only
OBJECT-TYPE    
  SleControlRequestResultType  

sleBypassOptionConnectivityControlAddress 1.3.6.1.4.1.6296.101.2.14.2.2.6
The target IP address of bypass health-checking
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

sleBypassOptionConnectivityControlPort 1.3.6.1.4.1.6296.101.2.14.2.2.7
he target port of bypass health-checking
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

sleBypassOptionConnectivityNotification 1.3.6.1.4.1.6296.101.2.14.2.3
OBJECT IDENTIFIER    

sleBypassOptionConnectivitySet 1.3.6.1.4.1.6296.101.2.14.2.3.1
Description.
Status: current Access: read-write
NOTIFICATION-TYPE    

sleBypassOptionConnectivityUnset 1.3.6.1.4.1.6296.101.2.14.2.3.2
Description.
Status: current Access: read-write
NOTIFICATION-TYPE    

sleBypassOptionPingTable 1.3.6.1.4.1.6296.101.2.14.2.4
Description.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SleBypassOptionPingEntry

sleBypassOptionPingEntry 1.3.6.1.4.1.6296.101.2.14.2.4.1
Description.
Status: current Access: not-accessible
OBJECT-TYPE    
  SleBypassOptionPingEntry  

sleBypassOptionPingAddress 1.3.6.1.4.1.6296.101.2.14.2.4.1.1
The target IP address of bypass ping health checking
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

sleBypassOptionPingTransInterval 1.3.6.1.4.1.6296.101.2.14.2.4.1.2
The ping transaction interval
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sleBypassOptionPingTranNumber 1.3.6.1.4.1.6296.101.2.14.2.4.1.3
The ping transaction request number
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sleBypassOptionPingReqInterval 1.3.6.1.4.1.6296.101.2.14.2.4.1.4
The ping request interval
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sleBypassOptionPingReqTimeout 1.3.6.1.4.1.6296.101.2.14.2.4.1.5
The ping request timeout
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sleBypassOptionPingLossThresh 1.3.6.1.4.1.6296.101.2.14.2.4.1.6
The ping loss threshold
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sleBypassOptionPingControl 1.3.6.1.4.1.6296.101.2.14.2.5
OBJECT IDENTIFIER    

sleBypassOptionPingControlRequest 1.3.6.1.4.1.6296.101.2.14.2.5.1
The request of a user command.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER setBypassPing(1), unsetBypassPing(2)  

sleBypassOptionPingControlStatus 1.3.6.1.4.1.6296.101.2.14.2.5.2
The status of user command.
Status: current Access: read-only
OBJECT-TYPE    
  SleControlStatusType  

sleBypassOptionPingControlTimer 1.3.6.1.4.1.6296.101.2.14.2.5.3
The maximum time for the manager for a long running user command.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

sleBypassOptionPingControlTimeStamp 1.3.6.1.4.1.6296.101.2.14.2.5.4
The time stamp of the last command(end of command).
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

sleBypassOptionPingControlReqResult 1.3.6.1.4.1.6296.101.2.14.2.5.5
The result of user command.
Status: current Access: read-only
OBJECT-TYPE    
  SleControlRequestResultType  

sleBypassOptionPingControlAddress 1.3.6.1.4.1.6296.101.2.14.2.5.6
The target IP address of bypass ping health-checking
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

sleBypassOptionPingControlTransInterval 1.3.6.1.4.1.6296.101.2.14.2.5.7
The ping transaction interval
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

sleBypassOptionPingControlTranNumber 1.3.6.1.4.1.6296.101.2.14.2.5.8
The ping transaction request number
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

sleBypassOptionPingControlReqInterval 1.3.6.1.4.1.6296.101.2.14.2.5.9
The ping request interval
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

sleBypassOptionPingControlReqTimeout 1.3.6.1.4.1.6296.101.2.14.2.5.10
The ping request timeout
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

sleBypassOptionPingControlLossThresh 1.3.6.1.4.1.6296.101.2.14.2.5.11
The ping loss threshold
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

sleBypassOptionPingNotification 1.3.6.1.4.1.6296.101.2.14.2.6
OBJECT IDENTIFIER    

sleBypassOptionPingSet 1.3.6.1.4.1.6296.101.2.14.2.6.1
Description.
Status: current Access: read-write
NOTIFICATION-TYPE    

sleBypassOptionPingUnset 1.3.6.1.4.1.6296.101.2.14.2.6.2
Description.
Status: current Access: read-write
NOTIFICATION-TYPE    

sleBypassOptionLinkMonitorTable 1.3.6.1.4.1.6296.101.2.14.2.7
Description.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SleBypassOptionLinkMonitorEntry

sleBypassOptionLinkMonitorEntry 1.3.6.1.4.1.6296.101.2.14.2.7.1
Description.
Status: current Access: not-accessible
OBJECT-TYPE    
  SleBypassOptionLinkMonitorEntry  

sleBypassOptionLinkMonitorPort 1.3.6.1.4.1.6296.101.2.14.2.7.1.1
The port of bypass link health-checking
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..65535  

sleBypassOptionLinkMonitorPortStatus 1.3.6.1.4.1.6296.101.2.14.2.7.1.2
The port status of bypass link health-checking
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enable(1)  

sleBypassOptionLinkMonitorControl 1.3.6.1.4.1.6296.101.2.14.2.8
OBJECT IDENTIFIER    

sleBypassOptionLinkMonitorControlRequest 1.3.6.1.4.1.6296.101.2.14.2.8.1
The request of a user command.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER setBypassLinkMonitor(1)  

sleBypassOptionLinkMonitorControlStatus 1.3.6.1.4.1.6296.101.2.14.2.8.2
The status of user command.
Status: current Access: read-only
OBJECT-TYPE    
  SleControlStatusType  

sleBypassOptionLinkMonitorControlTimer 1.3.6.1.4.1.6296.101.2.14.2.8.3
The maximum time for the manager for a long running user command.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

sleBypassOptionLinkMonitorControlTimeStamp 1.3.6.1.4.1.6296.101.2.14.2.8.4
The time stamp of the last command(end of command).
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

sleBypassOptionLinkMonitorControlReqResult 1.3.6.1.4.1.6296.101.2.14.2.8.5
The result of user command.
Status: current Access: read-only
OBJECT-TYPE    
  SleControlRequestResultType  

sleBypassOptionLinkMonitorControlPort 1.3.6.1.4.1.6296.101.2.14.2.8.6
The port of bypass link health-checking
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

sleBypassOptionLinkMonitorControlPortStatus 1.3.6.1.4.1.6296.101.2.14.2.8.7
The port status of bypass link health-checking
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

sleBypassOptioLinkMonitorNotification 1.3.6.1.4.1.6296.101.2.14.2.9
OBJECT IDENTIFIER    

sleBypassOptionLinkMonitorChanged 1.3.6.1.4.1.6296.101.2.14.2.9.1
Description.
Status: current Access: read-write
NOTIFICATION-TYPE    

sleHFC 1.3.6.1.4.1.6296.101.2.15
OBJECT IDENTIFIER    

sleHFCTable 1.3.6.1.4.1.6296.101.2.15.1
Description.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SleHFCEntry

sleHFCEntry 1.3.6.1.4.1.6296.101.2.15.1.1
Description.
Status: current Access: not-accessible
OBJECT-TYPE    
  SleHFCEntry  

sleHFCOptic1550OTX 1.3.6.1.4.1.6296.101.2.15.1.1.1
HFC Optic 1550 OTX value.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleHFCOptic1550OTXAlarm 1.3.6.1.4.1.6296.101.2.15.1.1.2
HFC Optic 1550 OTX alarm status.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(0), on(1)  

sleHFCOpticUpstreamOTX 1.3.6.1.4.1.6296.101.2.15.1.1.3
HFC Optic Upstream OTX value.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleHFCOpticUpstreamOTXAlarm 1.3.6.1.4.1.6296.101.2.15.1.1.4
HFC Optic Upstream OTX alarm status.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(0), on(1)  

sleHFCOpticDownstreamORX 1.3.6.1.4.1.6296.101.2.15.1.1.5
HFC Optic Downstream ORX value.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleHFCOpticDownstreamORXAlarm 1.3.6.1.4.1.6296.101.2.15.1.1.6
HFC Optic Downstream ORX alarm status.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(0), on(1)  

sleHFCEDFA1OTX 1.3.6.1.4.1.6296.101.2.15.1.1.7
HFC EDFA1 OTX value.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleHFCEDFA1OTXAlarm 1.3.6.1.4.1.6296.101.2.15.1.1.8
HFC EDFA1 OTX alarm status.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(0), on(1)  

sleHFCEDFA1ORX 1.3.6.1.4.1.6296.101.2.15.1.1.9
HFC EDFA1 ORX value.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleHFCEDFA1ORXAlarm 1.3.6.1.4.1.6296.101.2.15.1.1.10
HFC EDFA1 ORX alarm status.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(0), on(1)  

sleHFCEDFA1LD1Current 1.3.6.1.4.1.6296.101.2.15.1.1.11
HFC EDFA1 LD1 Current value.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleHFCEDFA1LD1CurrentAlarm 1.3.6.1.4.1.6296.101.2.15.1.1.12
HFC EDFA1 LD1 Current alarm status.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(0), on(1)  

sleHFCEDFA1LD2Current 1.3.6.1.4.1.6296.101.2.15.1.1.13
HFC EDFA1 LD2 Current value.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleHFCEDFA1LD2CurrentAlarm 1.3.6.1.4.1.6296.101.2.15.1.1.14
HFC EDFA1 LD2 Current alarm status.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(0), on(1)  

sleHFCEDFA1LD1Temp 1.3.6.1.4.1.6296.101.2.15.1.1.15
HFC EDFA1 LD1 Temp value.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleHFCEDFA1LD1TempAlarm 1.3.6.1.4.1.6296.101.2.15.1.1.16
HFC EDFA1 LD1 Temp alarm status.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(0), on(1)  

sleHFCEDFA1LD2Temp 1.3.6.1.4.1.6296.101.2.15.1.1.17
HFC EDFA1 LD2 Temp value.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleHFCEDFA1LD2TempAlarm 1.3.6.1.4.1.6296.101.2.15.1.1.18
HFC EDFA1 LD2 Temp alarm status.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(0), on(1)  

sleHFCEDFA1CaseTemp 1.3.6.1.4.1.6296.101.2.15.1.1.19
HFC EDFA1 Case Temp value.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleHFCEDFA1CaseTempAlarm 1.3.6.1.4.1.6296.101.2.15.1.1.20
HFC EDFA1 Case Temp alarm status.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(0), on(1)  

sleHFCEDFA2OTX 1.3.6.1.4.1.6296.101.2.15.1.1.21
HFC EDFA2 OTX value.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleHFCEDFA2OTXAarm 1.3.6.1.4.1.6296.101.2.15.1.1.22
HFC EDFA2 OTX alarm status.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(0), on(1)  

sleHFCEDFA2ORX 1.3.6.1.4.1.6296.101.2.15.1.1.23
HFC EDFA2 ORX value.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleHFCEDFA2ORXAlarm 1.3.6.1.4.1.6296.101.2.15.1.1.24
HFC EDFA2 ORX alarm status.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(0), on(1)  

sleHFCEDFA2LD1Current 1.3.6.1.4.1.6296.101.2.15.1.1.25
HFC EDFA2 LD1 Current value.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleHFCEDFA2LD1CurrentAlarm 1.3.6.1.4.1.6296.101.2.15.1.1.26
HFC EDFA2 LD1 Current alarm status.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(0), on(1)  

sleHFCEDFA2LD2Current 1.3.6.1.4.1.6296.101.2.15.1.1.27
HFC EDFA2 LD2 Current value.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleHFCEDFA2LD2CurrentAlarm 1.3.6.1.4.1.6296.101.2.15.1.1.28
HFC EDFA2 LD2 Current alarm status.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(0), on(1)  

sleHFCEDFA2LD1Temp 1.3.6.1.4.1.6296.101.2.15.1.1.29
HFC EDFA2 LD1 Temp value.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleHFCEDFA2LD1TempAlarm 1.3.6.1.4.1.6296.101.2.15.1.1.30
HFC EDFA2 LD1 Temp alarm status.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(0), on(1)  

sleHFCEDFA2LD2Temp 1.3.6.1.4.1.6296.101.2.15.1.1.31
HFC EDFA2 LD2 Temp value.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleHFCEDFA2LD2TempAlarm 1.3.6.1.4.1.6296.101.2.15.1.1.32
HFC EDFA2 LD2 Temp alarm status.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(0), on(1)  

sleHFCEDFA2CaseTemp 1.3.6.1.4.1.6296.101.2.15.1.1.33
HFC EDFA2 Case Temp value.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sleHFCEDFA2CaseTempAlarm 1.3.6.1.4.1.6296.101.2.15.1.1.34
HFC EDFA2 Case Temp alarm status.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(0), on(1)  

sleHFCControl 1.3.6.1.4.1.6296.101.2.15.2
OBJECT IDENTIFIER    

sleHFCControlRequest 1.3.6.1.4.1.6296.101.2.15.2.1
The request of a user command
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER setHFCAlarmStatus(1)  

sleHFCControlStatus 1.3.6.1.4.1.6296.101.2.15.2.2
The status of user command
Status: current Access: read-only
OBJECT-TYPE    
  SleControlStatusType  

sleHFCControlTimer 1.3.6.1.4.1.6296.101.2.15.2.3
The maximum time for the manager for a long running user command.
Status: current Access: read-write
OBJECT-TYPE    
  Gauge32  

sleHFCControlTimeStamp 1.3.6.1.4.1.6296.101.2.15.2.4
The time stamp of the last command(end of command)
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

sleHFCControlReqResult 1.3.6.1.4.1.6296.101.2.15.2.5
The result of the last user command
Status: current Access: read-only
OBJECT-TYPE    
  SleControlRequestResultType  

sleHFCControlAlarmIndex 1.3.6.1.4.1.6296.101.2.15.2.6
The HFC alarm index , edfa1 /edfa2 /optic .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER hfcefda1(0), hfcefda2(1), hfcoptic(2)  

sleHFCControlAlarmStatus 1.3.6.1.4.1.6296.101.2.15.2.7
The HFC alrm status.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(0), enable(1)  

sleHFCNotification 1.3.6.1.4.1.6296.101.2.15.3
OBJECT IDENTIFIER    

sleHFCOpticAlarmStatusChanged 1.3.6.1.4.1.6296.101.2.15.3.1
HFC Alarm Status Changed.
Status: current Access: read-write
NOTIFICATION-TYPE    

sleDeviceGroup 1.3.6.1.4.1.6296.101.2.16
Description.
Status: current Access: read-write
OBJECT-GROUP    

sleDeviceNotificationGroup 1.3.6.1.4.1.6296.101.2.17
Description.
Status: current Access: read-write
NOTIFICATION-GROUP