SL-SONET-SUP-PM-MIB

File: SL-SONET-SUP-PM-MIB.mib (93181 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC SNMPv2-CONF
PerfHist-TC-MIB SONET-MIB IF-MIB
SL-SONET-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE NOTIFICATION-TYPE
Integer32 transmission Gauge32
TruthValue DateAndTime OBJECT-GROUP
NOTIFICATION-GROUP MODULE-COMPLIANCE PerfCurrentCount
PerfIntervalCount PerfTotalCount sonetMediumEntry
sonetSectionCurrentEntry sonetSectionIntervalEntry sonetLineCurrentEntry
sonetLineIntervalEntry sonetFarEndLineCurrentEntry sonetFarEndLineIntervalEntry
sonetPathCurrentEntry sonetPathIntervalEntry sonetFarEndPathCurrentEntry
sonetFarEndPathIntervalEntry sonetVTCurrentEntry sonetVTIntervalEntry
sonetFarEndVTCurrentEntry sonetFarEndVTIntervalEntry ifIndex
slSonetMib

Defined Types

SonetSectionDefaultThresholdEntry  
SEQUENCE    
  sonetSectionDefaultThresholdRate INTEGER
  sonetSectionDefaultCVThreshold INTEGER
  sonetSectionDefaultESThreshold INTEGER
  sonetSectionDefaultSESThreshold INTEGER
  sonetSectionDefaultSEFSThreshold INTEGER
  sonetSectionDefaultDayCVThreshold INTEGER
  sonetSectionDefaultDayESThreshold INTEGER
  sonetSectionDefaultDaySESThreshold INTEGER
  sonetSectionDefaultDaySEFSThreshold INTEGER

SonetSectionThresholdEntry  
SEQUENCE    
  sonetSectionCurrentCVThreshold INTEGER
  sonetSectionCurrentESThreshold INTEGER
  sonetSectionCurrentSESThreshold INTEGER
  sonetSectionCurrentSEFSThreshold INTEGER
  sonetSectionDayCVThreshold INTEGER
  sonetSectionDayESThreshold INTEGER
  sonetSectionDaySESThreshold INTEGER
  sonetSectionDaySEFSThreshold INTEGER

SonetSectionDayEntry  
SEQUENCE    
  sonetSectionDayNumber INTEGER
  sonetSectionDayStartTime DateAndTime
  sonetSectionDayValidData TruthValue
  sonetSectionDayCVs PerfTotalCount
  sonetSectionDayESs PerfTotalCount
  sonetSectionDaySESs PerfTotalCount
  sonetSectionDaySEFSs PerfTotalCount
  sonetSectionDayTcaFlag TruthValue
  sonetSectionDayReset INTEGER

SonetLineDefaultThresholdEntry  
SEQUENCE    
  sonetLineDefaultThresholdDirection INTEGER
  sonetLineDefaultThresholdRate INTEGER
  sonetLineDefaultCVThreshold INTEGER
  sonetLineDefaultESThreshold INTEGER
  sonetLineDefaultSESThreshold INTEGER
  sonetLineDefaultUASThreshold INTEGER
  sonetLineDefaultDayCVThreshold INTEGER
  sonetLineDefaultDayESThreshold INTEGER
  sonetLineDefaultDaySESThreshold INTEGER
  sonetLineDefaultDayUASThreshold INTEGER

SonetLineThresholdEntry  
SEQUENCE    
  sonetLineThresholdDirection INTEGER
  sonetLineCurrentCVThreshold INTEGER
  sonetLineCurrentESThreshold INTEGER
  sonetLineCurrentSESThreshold INTEGER
  sonetLineCurrentUASThreshold INTEGER
  sonetLineDayCVThreshold INTEGER
  sonetLineDayESThreshold INTEGER
  sonetLineDaySESThreshold INTEGER
  sonetLineDayUASThreshold INTEGER

SonetLineDayEntry  
SEQUENCE    
  sonetLineDayNumber INTEGER
  sonetLineDayStartTime DateAndTime
  sonetLineDayValidData TruthValue
  sonetLineDayCVs PerfTotalCount
  sonetLineDayESs PerfTotalCount
  sonetLineDaySESs PerfTotalCount
  sonetLineDayUASs PerfTotalCount
  sonetLineDayPSC PerfTotalCount
  sonetLineDayPSD PerfTotalCount
  sonetLineDayFCs PerfTotalCount
  sonetLineDayTcaFlag TruthValue
  sonetLineDayReset INTEGER

SonetFarEndLineDayEntry  
SEQUENCE    
  sonetFarEndLineDayNumber INTEGER
  sonetFarEndLineDayStartTime DateAndTime
  sonetFarEndLineDayValidData TruthValue
  sonetFarEndLineDayCVs PerfTotalCount
  sonetFarEndLineDayESs PerfTotalCount
  sonetFarEndLineDaySESs PerfTotalCount
  sonetFarEndLineDayUASs PerfTotalCount
  sonetFarEndLineDayFCs PerfTotalCount
  sonetFarEndLineDayTcaFlag TruthValue
  sonetFarEndLineDayReset INTEGER

SonetPathDefaultThresholdEntry  
SEQUENCE    
  sonetPathDefaultThresholdDirection INTEGER
  sonetPathDefaultThresholdRate INTEGER
  sonetPathDefaultCVThreshold INTEGER
  sonetPathDefaultESThreshold INTEGER
  sonetPathDefaultSESThreshold INTEGER
  sonetPathDefaultUASThreshold INTEGER
  sonetPathDefaultDayCVThreshold INTEGER
  sonetPathDefaultDayESThreshold INTEGER
  sonetPathDefaultDaySESThreshold INTEGER
  sonetPathDefaultDayUASThreshold INTEGER

SonetPathThresholdEntry  
SEQUENCE    
  sonetPathThresholdDirection INTEGER
  sonetPathCurrentCVThreshold INTEGER
  sonetPathCurrentESThreshold INTEGER
  sonetPathCurrentSESThreshold INTEGER
  sonetPathCurrentUASThreshold INTEGER
  sonetPathDayCVThreshold INTEGER
  sonetPathDayESThreshold INTEGER
  sonetPathDaySESThreshold INTEGER
  sonetPathDayUASThreshold INTEGER

SonetPathDayEntry  
SEQUENCE    
  sonetPathDayNumber INTEGER
  sonetPathDayStartTime DateAndTime
  sonetPathDayValidData TruthValue
  sonetPathDayCVs PerfTotalCount
  sonetPathDayESs PerfTotalCount
  sonetPathDaySESs PerfTotalCount
  sonetPathDayUASs PerfTotalCount
  sonetPathDayFCs PerfTotalCount
  sonetPathDayTcaFlag TruthValue
  sonetPathDayEBs PerfTotalCount
  sonetPathDayReset INTEGER

SonetFarEndPathDayEntry  
SEQUENCE    
  sonetFarEndPathDayNumber INTEGER
  sonetFarEndPathDayStartTime DateAndTime
  sonetFarEndPathDayValidData TruthValue
  sonetFarEndPathDayCVs PerfTotalCount
  sonetFarEndPathDayESs PerfTotalCount
  sonetFarEndPathDaySESs PerfTotalCount
  sonetFarEndPathDayUASs PerfTotalCount
  sonetFarEndPathDayFCs PerfTotalCount
  sonetFarEndPathDayTcaFlag TruthValue
  sonetFarEndPathDayEBs PerfTotalCount
  sonetFarEndPathDayReset INTEGER

SonetVTDefaultThresholdEntry  
SEQUENCE    
  sonetVTDefaultThresholdDirection INTEGER
  sonetVTDefaultThresholdRate INTEGER
  sonetVTDefaultCVThreshold INTEGER
  sonetVTDefaultESThreshold INTEGER
  sonetVTDefaultSESThreshold INTEGER
  sonetVTDefaultUASThreshold INTEGER
  sonetVTDefaultDayCVThreshold INTEGER
  sonetVTDefaultDayESThreshold INTEGER
  sonetVTDefaultDaySESThreshold INTEGER
  sonetVTDefaultDayUASThreshold INTEGER

SonetVTThresholdEntry  
SEQUENCE    
  sonetVTCurrentCVThreshold INTEGER
  sonetVTCurrentESThreshold INTEGER
  sonetVTCurrentSESThreshold INTEGER
  sonetVTCurrentUASThreshold INTEGER
  sonetVTDayCVThreshold INTEGER
  sonetVTDayESThreshold INTEGER
  sonetVTDaySESThreshold INTEGER
  sonetVTDayUASThreshold INTEGER

SonetVTDayEntry  
SEQUENCE    
  sonetVTDayNumber INTEGER
  sonetVTDayStartTime DateAndTime
  sonetVTDayValidData TruthValue
  sonetVTDayFCs PerfTotalCount
  sonetVTDayCVs PerfTotalCount
  sonetVTDayESs PerfTotalCount
  sonetVTDaySESs PerfTotalCount
  sonetVTDayUASs PerfTotalCount
  sonetVTDayEBs PerfTotalCount
  sonetVTDayTcaFlag TruthValue
  sonetVTDayReset INTEGER

SonetFarEndVTDayEntry  
SEQUENCE    
  sonetFarEndVTDayNumber INTEGER
  sonetFarEndVTDayStartTime DateAndTime
  sonetFarEndVTDayValidData TruthValue
  sonetFarEndVTDayFCs PerfTotalCount
  sonetFarEndVTDayCVs PerfTotalCount
  sonetFarEndVTDayESs PerfTotalCount
  sonetFarEndVTDaySESs PerfTotalCount
  sonetFarEndVTDayUASs PerfTotalCount
  sonetFarEndVTDayEBs PerfTotalCount
  sonetFarEndVTDayTcaFlag TruthValue
  sonetFarEndVTDayReset INTEGER

Defined Values

sonetSupPmMIB 1.3.6.1.4.1.4515.1.6.3
This MIB module provides extensions to the SONET-MIB (RFC 2558) objects. It provides definitions for management information that supports those parts of ANSI T1.231-1997 that are not covered by the SONET-MIB.
MODULE-IDENTITY    

sonetSupObjects 1.3.6.1.4.1.4515.1.6.3.1
OBJECT IDENTIFIER    

sonetSupObjectsPath 1.3.6.1.4.1.4515.1.6.3.2
OBJECT IDENTIFIER    

sonetSupObjectsVT 1.3.6.1.4.1.4515.1.6.3.3
OBJECT IDENTIFIER    

sonetSupConfig 1.3.6.1.4.1.4515.1.6.3.1.1
OBJECT IDENTIFIER    

sonetSupMedium 1.3.6.1.4.1.4515.1.6.3.1.2
OBJECT IDENTIFIER    

sonetSupSection 1.3.6.1.4.1.4515.1.6.3.1.3
OBJECT IDENTIFIER    

sonetSupLine 1.3.6.1.4.1.4515.1.6.3.1.4
OBJECT IDENTIFIER    

sonetSupFarEndLine 1.3.6.1.4.1.4515.1.6.3.1.5
OBJECT IDENTIFIER    

sonetSupPath 1.3.6.1.4.1.4515.1.6.3.2.1
OBJECT IDENTIFIER    

sonetSupFarEndPath 1.3.6.1.4.1.4515.1.6.3.2.2
OBJECT IDENTIFIER    

sonetSupVT 1.3.6.1.4.1.4515.1.6.3.3.1
OBJECT IDENTIFIER    

sonetSupFarEndVT 1.3.6.1.4.1.4515.1.6.3.3.2
OBJECT IDENTIFIER    

sonetSectionDefaultThresholdTable 1.3.6.1.4.1.4515.1.6.3.1.3.1
The table of default thresholds for SONET section counters.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SonetSectionDefaultThresholdEntry

sonetSectionDefaultThresholdEntry 1.3.6.1.4.1.4515.1.6.3.1.3.1.1
An entry in the table of default thresholds. The table has a variable for each counter type and accumulation period combination, but uses an index to indetify the digital signal rate. The agent must provide a set of default threshold values for all rates that the NE supports. The agent may make these variables read-only.
Status: current Access: not-accessible
OBJECT-TYPE    
  SonetSectionDefaultThresholdEntry  

sonetSectionDefaultThresholdRate 1.3.6.1.4.1.4515.1.6.3.1.3.1.1.1
The digital signal rate for which the default threshold values apply.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER oc1(1), oc3(2), oc12(3), oc24(4), oc48(5), oc192(6)  

sonetSectionDefaultCVThreshold 1.3.6.1.4.1.4515.1.6.3.1.3.1.1.2
The default value for SONET CV-S counter 15-minute interval thresholds.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

sonetSectionDefaultESThreshold 1.3.6.1.4.1.4515.1.6.3.1.3.1.1.3
The default value for SONET ES-S counter 15-minute interval thresholds.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

sonetSectionDefaultSESThreshold 1.3.6.1.4.1.4515.1.6.3.1.3.1.1.6
The default value for SONET SES-S counter 15-minute interval thresholds.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

sonetSectionDefaultSEFSThreshold 1.3.6.1.4.1.4515.1.6.3.1.3.1.1.7
The default value for SONET SEFS-S counter 15-minute interval thresholds.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

sonetSectionDefaultDayCVThreshold 1.3.6.1.4.1.4515.1.6.3.1.3.1.1.8
The default value for SONET CV-S counter 15-minute interval thresholds.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

sonetSectionDefaultDayESThreshold 1.3.6.1.4.1.4515.1.6.3.1.3.1.1.9
The default value for SONET ES-S counter 15-minute interval thresholds.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

sonetSectionDefaultDaySESThreshold 1.3.6.1.4.1.4515.1.6.3.1.3.1.1.12
The default value for SONET SES-S counter 15-minute interval thresholds.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

sonetSectionDefaultDaySEFSThreshold 1.3.6.1.4.1.4515.1.6.3.1.3.1.1.13
The default value for SONET SEFS-S counter 15-minute interval thresholds.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

sonetSectionThresholdTable 1.3.6.1.4.1.4515.1.6.3.1.3.2
The table of trap threshold values for SONET section counters.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SonetSectionThresholdEntry

sonetSectionThresholdEntry 1.3.6.1.4.1.4515.1.6.3.1.3.2.1
An entry in the table of SONET Section trap thresholds.
Status: current Access: not-accessible
OBJECT-TYPE    
  SonetSectionThresholdEntry  

sonetSectionCurrentCVThreshold 1.3.6.1.4.1.4515.1.6.3.1.3.2.1.1
The trap threshold value for the interface's current 15-minute interval CV-S counter. A value of zero indicates that the default threshold value is to be used.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

sonetSectionCurrentESThreshold 1.3.6.1.4.1.4515.1.6.3.1.3.2.1.2
The trap threshold value for the interface's current 15-minute interval ES-S counter. A value of zero indicates that the default threshold value is to be used.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

sonetSectionCurrentSESThreshold 1.3.6.1.4.1.4515.1.6.3.1.3.2.1.5
The trap threshold value for the interface's current 15-minute interval SES-S counter. A value of zero indicates that the default threshold value is to be used.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

sonetSectionCurrentSEFSThreshold 1.3.6.1.4.1.4515.1.6.3.1.3.2.1.6
The trap threshold value for the interface's current 15-minute interval SEFS-S counter. A value of zero indicates that the default threshold value is to be used.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

sonetSectionDayCVThreshold 1.3.6.1.4.1.4515.1.6.3.1.3.2.1.7
The trap threshold value for the interface's current day CV-S counter. A value of zero indicates that the default threshold value is to be used.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

sonetSectionDayESThreshold 1.3.6.1.4.1.4515.1.6.3.1.3.2.1.8
The trap threshold value for the interface's current day ES-S counter. A value of zero indicates that the default threshold value is to be used.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

sonetSectionDaySESThreshold 1.3.6.1.4.1.4515.1.6.3.1.3.2.1.11
The trap threshold value for the interface's current day SES-S counter. A value of zero indicates that the default threshold value is to be used.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

sonetSectionDaySEFSThreshold 1.3.6.1.4.1.4515.1.6.3.1.3.2.1.12
The trap threshold value for the interface's current day SEFS-S counter. A value of zero indicates that the default threshold value is to be used.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

sonetSectionDayTable 1.3.6.1.4.1.4515.1.6.3.1.3.15
The SONET Section Day table. Contains various statistics collected by each SONET Section over multiple 1-day intervals of operation.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SonetSectionDayEntry

sonetSectionDayEntry 1.3.6.1.4.1.4515.1.6.3.1.3.15.1
An entry in the SONET Section Day table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SonetSectionDayEntry  

sonetSectionDayNumber 1.3.6.1.4.1.4515.1.6.3.1.3.15.1.1
A number which identifies the 1-day interval for which the set of section related statistics is available. The number is between 1 and n, where n is the number of 1-day intervals supported by the agent. The interval identified by 1 is the current 1-day interval, 2 is the previous (most recently completed) 1-day interval and n is the least recently completed 1-day interval. Interval 0 is used for the Untimed counters.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..33  

sonetSectionDayStartTime 1.3.6.1.4.1.4515.1.6.3.1.3.15.1.2
This variable indicates the date and time at which this 1-day interval of sections measurements began on this interface.
Status: current Access: read-only
OBJECT-TYPE    
  DateAndTime  

sonetSectionDayValidData 1.3.6.1.4.1.4515.1.6.3.1.3.15.1.3
This variable assumes the value true(1) if the data stored for this interval is both valid and complete. It is set to false(2) if the data stored for this interval is incomplete or otherwise invalid because (a) the data stored for this interval is for a period greater or less than 24 hours, or (b) some data is missing.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

sonetSectionDayCVs 1.3.6.1.4.1.4515.1.6.3.1.3.15.1.4
The section code violation (CV-S) count is the number of BIP-8 errors which were detected at the SONET section layer interface in a previous 1-day interval. Each section BIP-8 can detect up to eight errors per STS-N frame, with each error incrementing the CV counter. CVs for the section layer are collected using the BIP-8 in the B1 byte located in the section overhead of STS-1 number 1.
Status: current Access: read-only
OBJECT-TYPE    
  PerfTotalCount  

sonetSectionDayESs 1.3.6.1.4.1.4515.1.6.3.1.3.15.1.5
The section errored second (ES-S) count is the number of 1-second intervals containing one or more BIP-8 error (B1 byte), one or more SEF defects, or one or more LOS defects which were encountered by the SONET section layer interface in a previous 1-day interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfTotalCount  

sonetSectionDaySESs 1.3.6.1.4.1.4515.1.6.3.1.3.15.1.8
The section severely errored second (SES-S) count is the number of 1-second intervals containing sonetSevereErrorThreshold or more BIP-8 errors (B1 byte), one or more SEF defects, or one or more LOS defects which were encountered by the SONET section layer interface in a previous 1-day interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfTotalCount  

sonetSectionDaySEFSs 1.3.6.1.4.1.4515.1.6.3.1.3.15.1.9
The section severely errored frame second (SEFS-S) count is the number of 1-second intervals containing one or more SEF defects which were encountered by the SONET section layer interface in a previous 1-day interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfTotalCount  

sonetSectionDayTcaFlag 1.3.6.1.4.1.4515.1.6.3.1.3.15.1.10
TRUE if one of the counters crossed the threshold during the day.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

sonetSectionDayReset 1.3.6.1.4.1.4515.1.6.3.1.3.15.1.11
Writing this object reset the PM counters of this interval.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

sonetLineDefaultThresholdTable 1.3.6.1.4.1.4515.1.6.3.1.4.1
The table of default thresholds for SONET Line counters.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SonetLineDefaultThresholdEntry

sonetLineDefaultThresholdEntry 1.3.6.1.4.1.4515.1.6.3.1.4.1.1
An entry in the table of default thresholds. The table has a variable for each counter type and accumulation period combination, but uses indexes to indetify the digital signal direction and rate. The agent must provide a set of default threshold values for all rates that the NE supports. The agent may make these variables read-only.
Status: current Access: not-accessible
OBJECT-TYPE    
  SonetLineDefaultThresholdEntry  

sonetLineDefaultThresholdDirection 1.3.6.1.4.1.4515.1.6.3.1.4.1.1.1
The digital signal direction for which the default threshold values apply.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER nearEnd(1), farEnd(2)  

sonetLineDefaultThresholdRate 1.3.6.1.4.1.4515.1.6.3.1.4.1.1.2
The digital signal rate for which the default threshold values apply.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER vt1dot5(1), vtg(2), oc1(3), oc3(4), oc12(5), oc24(6), oc48(7), oc192(8)  

sonetLineDefaultCVThreshold 1.3.6.1.4.1.4515.1.6.3.1.4.1.1.3
The default value for SONET CV-L and CV-LFE counter 15-minute interval thresholds.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

sonetLineDefaultESThreshold 1.3.6.1.4.1.4515.1.6.3.1.4.1.1.4
The default value for SONET ES-L and ES-LFE counter 15-minute interval thresholds.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

sonetLineDefaultSESThreshold 1.3.6.1.4.1.4515.1.6.3.1.4.1.1.7
The default value for SONET SES-L and SES-LFE counter 15-minute interval thresholds.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

sonetLineDefaultUASThreshold 1.3.6.1.4.1.4515.1.6.3.1.4.1.1.9
The default value for SONET UAS-L and UAS-LFE counter 15-minute interval thresholds.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

sonetLineDefaultDayCVThreshold 1.3.6.1.4.1.4515.1.6.3.1.4.1.1.10
The default value for SONET CV-L and CV-LFE counter 15-minute interval thresholds.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

sonetLineDefaultDayESThreshold 1.3.6.1.4.1.4515.1.6.3.1.4.1.1.11
The default value for SONET ES-L and ES-LFE counter 15-minute interval thresholds.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

sonetLineDefaultDaySESThreshold 1.3.6.1.4.1.4515.1.6.3.1.4.1.1.14
The default value for SONET SES-L and SES-LFE counter 15-minute interval thresholds.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

sonetLineDefaultDayUASThreshold 1.3.6.1.4.1.4515.1.6.3.1.4.1.1.16
The default value for SONET UAS-L and UAS-LFE counter 15-minute interval thresholds.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

sonetLineThresholdTable 1.3.6.1.4.1.4515.1.6.3.1.4.2
The table of trap threshold values for SONET Line counters.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SonetLineThresholdEntry

sonetLineThresholdEntry 1.3.6.1.4.1.4515.1.6.3.1.4.2.1
An entry in the table of SONET Line trap thresholds.
Status: current Access: not-accessible
OBJECT-TYPE    
  SonetLineThresholdEntry  

sonetLineThresholdDirection 1.3.6.1.4.1.4515.1.6.3.1.4.2.1.1
The digital signal direction for which the threshold values apply.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER nearEnd(1), farEnd(2)  

sonetLineCurrentCVThreshold 1.3.6.1.4.1.4515.1.6.3.1.4.2.1.2
The trap threshold value for the interface's current 15-minute interval CV-L and CV-LFE counters. A value of zero indicates that the default threshold value is to be used.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

sonetLineCurrentESThreshold 1.3.6.1.4.1.4515.1.6.3.1.4.2.1.3
The trap threshold value for the interface's current 15-minute interval ES-L and ES-LFE counters. A value of zero indicates that the default threshold value is to be used.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

sonetLineCurrentSESThreshold 1.3.6.1.4.1.4515.1.6.3.1.4.2.1.4
The trap threshold value for the interface's current 15-minute interval SES-L and SES-LFE counters. A value of zero indicates that the default threshold value is to be used.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

sonetLineCurrentUASThreshold 1.3.6.1.4.1.4515.1.6.3.1.4.2.1.5
The trap threshold value for the interface's current 15-minute interval UAS-L and UAS-LFE counters. A value of zero indicates that the default threshold value is to be used.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

sonetLineDayCVThreshold 1.3.6.1.4.1.4515.1.6.3.1.4.2.1.6
The trap threshold value for the interface's current day CV-L and CV-LFE counters. A value of zero indicates that the default threshold value is to be used.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

sonetLineDayESThreshold 1.3.6.1.4.1.4515.1.6.3.1.4.2.1.7
The trap threshold value for the interface's current day ES-L and ES-LFE counters. A value of zero indicates that the default threshold value is to be used.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

sonetLineDaySESThreshold 1.3.6.1.4.1.4515.1.6.3.1.4.2.1.8
The trap threshold value for the interface's current day SES-L and SES-LFE counters. A value of zero indicates that the default threshold value is to be used.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

sonetLineDayUASThreshold 1.3.6.1.4.1.4515.1.6.3.1.4.2.1.9
The trap threshold value for the interface's current day UAS-L and UAS-LFE counters. A value of zero indicates that the default threshold value is to be used.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

sonetLineDayTable 1.3.6.1.4.1.4515.1.6.3.1.4.5
The SONET Line Day table. Contains various statistics collected by each SONET line over multiple 1-day intervals of operation.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SonetLineDayEntry

sonetLineDayEntry 1.3.6.1.4.1.4515.1.6.3.1.4.5.1
An entry in the SONET Line Day table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SonetLineDayEntry  

sonetLineDayNumber 1.3.6.1.4.1.4515.1.6.3.1.4.5.1.1
A number which identifies the 1-day interval for which the set of near-end line related statistics is available. The number is between 1 and n, where n is the number of 1-day intervals supported by the agent. The interval identified by 1 is the current 1-day interval, 2 is the previous (most recently completed) 1-day interval and n is the least recently completed 1-day interval. Interval 0 is used for the Untimed counters.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..33  

sonetLineDayStartTime 1.3.6.1.4.1.4515.1.6.3.1.4.5.1.2
This variable indicates the date and time at which this 1-day interval of near-end line measurements began on this interface.
Status: current Access: read-only
OBJECT-TYPE    
  DateAndTime  

sonetLineDayValidData 1.3.6.1.4.1.4515.1.6.3.1.4.5.1.3
This variable assumes the value true(1) if the data stored for this interval is both valid and complete. It is set to false(2) if the data stored for this interval is incomplete or otherwise invalid because (a) the data stored for this interval is for a period greater or less than 24 hours, or (b) some data is missing.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

sonetLineDayCVs 1.3.6.1.4.1.4515.1.6.3.1.4.5.1.5
The line code violation (CV-L) count is the number of BIP-8 errors which were detected at the SONET line layer interface in a previous 1-day interval. Each line BIP-8 can detect up to eight errors per STS-1 frame, with each error incrementing the CV counter. CVs for the line layer are collected using the BIP-8s in the B2 byte located in the line overhead of STS-1. (Since all CVs on an STS-N line are counted together, this is equivalent to counting each error in the BIP-8N contained in the B2 bytes of the STS-N line overhead.) Thus, on an STS-N signal, up to 8 x N CVs may occure in each STS-N frame.
Status: current Access: read-only
OBJECT-TYPE    
  PerfTotalCount  

sonetLineDayESs 1.3.6.1.4.1.4515.1.6.3.1.4.5.1.6
The line errored second (ES-L) count is the number of 1-second intervals containing one or more EDC error (B2 byte), or one or more AIS-L defects which were encountered by the SONET line layer interface in a previous 1-day interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfTotalCount  

sonetLineDaySESs 1.3.6.1.4.1.4515.1.6.3.1.4.5.1.9
The line severely errored second (SES-L) is a count of 1-second intervals containing sonetSevereErrorThreshold or more EDC errors (B2 byte) or one or more AIS-L defects which were encountered by the SONET line layer interface in a previous 1-day interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfTotalCount  

sonetLineDayUASs 1.3.6.1.4.1.4515.1.6.3.1.4.5.1.10
The line unavailable second (UAS-L) is a count of 1-second intervals for which the SONET line was unavailable during a previous 1-day interval. The SONET line becomes unavailable at the onset of 10 contiguous SES-Ls. The 10 SES-Ls are included in unavailable time. Once unavailable, the SONET line becomes available at the onset of 10 contiguous seconds with no SES-Ls. The 10 seconds with no SES-Ls are excluded from unavailable time.
Status: current Access: read-only
OBJECT-TYPE    
  PerfTotalCount  

sonetLineDayPSC 1.3.6.1.4.1.4515.1.6.3.1.4.5.1.11
The number of protection switching occured.
Status: current Access: read-only
OBJECT-TYPE    
  PerfTotalCount  

sonetLineDayPSD 1.3.6.1.4.1.4515.1.6.3.1.4.5.1.12
The length of time in seconds, where the protection unit was in service and the working unit was out of service, during the day.
Status: current Access: read-only
OBJECT-TYPE    
  PerfTotalCount  

sonetLineDayFCs 1.3.6.1.4.1.4515.1.6.3.1.4.5.1.13
The number of failure counts occured during the day.
Status: current Access: read-only
OBJECT-TYPE    
  PerfTotalCount  

sonetLineDayTcaFlag 1.3.6.1.4.1.4515.1.6.3.1.4.5.1.14
TRUE if one of the counters crossed the threshold during the day.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

sonetLineDayReset 1.3.6.1.4.1.4515.1.6.3.1.4.5.1.15
Writing this object reset the PM counters of this interval.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

sonetFarEndLineDayTable 1.3.6.1.4.1.4515.1.6.3.1.5.3
The SONET Far End Line Day table. Contains various statistics collected by each SONET line over multiple 1-day intervals of operation.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SonetFarEndLineDayEntry

sonetFarEndLineDayEntry 1.3.6.1.4.1.4515.1.6.3.1.5.3.1
An entry in the SONET Far End Line Day table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SonetFarEndLineDayEntry  

sonetFarEndLineDayNumber 1.3.6.1.4.1.4515.1.6.3.1.5.3.1.1
A number which identifies the 1-day interval for which the set of far-end line related statistics is available. The number is between 1 and n, where n is the number of 1-day intervals supported by the agent. The interval identified by 1 is the current 1-day interval, 2 is the previous (most recently completed) 1-day interval and n is the least recently completed 1-day interval.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..33  

sonetFarEndLineDayStartTime 1.3.6.1.4.1.4515.1.6.3.1.5.3.1.2
This variable indicates the date and time at which this 1-day interval of far-end line measurements began on this interface.
Status: current Access: read-only
OBJECT-TYPE    
  DateAndTime  

sonetFarEndLineDayValidData 1.3.6.1.4.1.4515.1.6.3.1.5.3.1.3
This variable assumes the value true(1) if the data stored for this interval is both valid and complete. It is set to false(2) if the data stored for this interval is incomplete or otherwise invalid because (a) the data stored for this interval is for a period greater or less than 24 hours, or (b) some data is missing (e.g., when a near-end defect prevents some far-end data from being collected).
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

sonetFarEndLineDayCVs 1.3.6.1.4.1.4515.1.6.3.1.5.3.1.5
The far-end line code violation (CV-LFE) count is the number of REI-Ls which were detected at the SONET line layer interface in a previous 1-day interval. For EC-1 or OC-1, REI-L is bits 5 to 8 of the M0 byte; for EC-N or OC-N (N>2), M1 byte.
Status: current Access: read-only
OBJECT-TYPE    
  PerfTotalCount  

sonetFarEndLineDayESs 1.3.6.1.4.1.4515.1.6.3.1.5.3.1.6
The far-end line errored second (ES-LFE) count is the number of 1-second intervals containing one or more REDC-Ls, or one or more RDI-L defects which were encountered by the SONET line layer interface in a previous 1-day interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfTotalCount  

sonetFarEndLineDaySESs 1.3.6.1.4.1.4515.1.6.3.1.5.3.1.9
The far-end line severely errored second (SES-LFE) is a count of 1-second intervals containing sonetSevereErrorThreshold or more REDC-Ls or one or more RDI-L defects which were detected by the SONET line layer interface in a previous 1-day interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfTotalCount  

sonetFarEndLineDayUASs 1.3.6.1.4.1.4515.1.6.3.1.5.3.1.10
The far-end line unavailable second (UAS-LFE) is a count of 1-second intervals for which the SONET line was unavailable during a previous 1-day interval. The SONET line becomes unavailable at the onset of 10 contiguous SES-LEFs. The 10 SES-LEFs are included in unavailable time. Once unavailable, the SONET line becomes available at the onset of 10 contiguous seconds with no SES-LEFs. The 10 seconds with no SES-LEFs are excluded from unavailable time.
Status: current Access: read-only
OBJECT-TYPE    
  PerfTotalCount  

sonetFarEndLineDayFCs 1.3.6.1.4.1.4515.1.6.3.1.5.3.1.11
The far-end line failures count.
Status: current Access: read-only
OBJECT-TYPE    
  PerfTotalCount  

sonetFarEndLineDayTcaFlag 1.3.6.1.4.1.4515.1.6.3.1.5.3.1.12
TRUE if one of the counters crossed the threshold during the day.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

sonetFarEndLineDayReset 1.3.6.1.4.1.4515.1.6.3.1.5.3.1.13
Writing this object reset the PM counters of this interval.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

sonetPathDefaultThresholdTable 1.3.6.1.4.1.4515.1.6.3.2.1.1
The table of default thresholds for SONET Path counters.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SonetPathDefaultThresholdEntry

sonetPathDefaultThresholdEntry 1.3.6.1.4.1.4515.1.6.3.2.1.1.1
An entry in the table of default thresholds. The table has a variable for each counter type and accumulation period combination, but uses indexes to indetify the digital signal direction and rate. The agent must provide a set of default threshold values for all rates that the NE supports. The agent may make these variables read-only.
Status: current Access: not-accessible
OBJECT-TYPE    
  SonetPathDefaultThresholdEntry  

sonetPathDefaultThresholdDirection 1.3.6.1.4.1.4515.1.6.3.2.1.1.1.1
The digital signal direction for which the default threshold values apply.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER nearEnd(1), farEnd(2)  

sonetPathDefaultThresholdRate 1.3.6.1.4.1.4515.1.6.3.2.1.1.1.2
The path digital signal rate for which the default threshold values apply.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER sts1(1), sts3(2), sts12(3), sts24(4), sts48(5), sts192(6)  

sonetPathDefaultCVThreshold 1.3.6.1.4.1.4515.1.6.3.2.1.1.1.3
The default value for SONET CV-P and CV-PFE counter 15-minute interval thresholds.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

sonetPathDefaultESThreshold 1.3.6.1.4.1.4515.1.6.3.2.1.1.1.4
The default value for SONET ES-P and ES-PFE counter 15-minute interval thresholds.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

sonetPathDefaultSESThreshold 1.3.6.1.4.1.4515.1.6.3.2.1.1.1.7
The default value for SONET SES-P and SES-PFE counter 15-minute interval thresholds.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

sonetPathDefaultUASThreshold 1.3.6.1.4.1.4515.1.6.3.2.1.1.1.8
The default value for SONET UAS-P and UAS-PFE counter 15-minute interval thresholds.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

sonetPathDefaultDayCVThreshold 1.3.6.1.4.1.4515.1.6.3.2.1.1.1.16
The default value for SONET CV-P and CV-PFE counter 1-day interval thresholds.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

sonetPathDefaultDayESThreshold 1.3.6.1.4.1.4515.1.6.3.2.1.1.1.17
The default value for SONET ES-P and ES-PFE counter 1-day interval thresholds.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

sonetPathDefaultDaySESThreshold 1.3.6.1.4.1.4515.1.6.3.2.1.1.1.20
The default value for SONET SES-P and SES-PFE counter 1-day interval thresholds.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

sonetPathDefaultDayUASThreshold 1.3.6.1.4.1.4515.1.6.3.2.1.1.1.21
The default value for SONET UAS-P and UAS-PFE counter 1-day interval thresholds.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

sonetPathThresholdTable 1.3.6.1.4.1.4515.1.6.3.2.1.2
The table of trap threshold values for SONET Path counters.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SonetPathThresholdEntry

sonetPathThresholdEntry 1.3.6.1.4.1.4515.1.6.3.2.1.2.1
An entry in the table of SONET Path trap thresholds.
Status: current Access: not-accessible
OBJECT-TYPE    
  SonetPathThresholdEntry  

sonetPathThresholdDirection 1.3.6.1.4.1.4515.1.6.3.2.1.2.1.1
The digital signal direction for which the threshold values apply.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER nearEnd(1), farEnd(2)  

sonetPathCurrentCVThreshold 1.3.6.1.4.1.4515.1.6.3.2.1.2.1.2
The trap threshold value for the interface's current 15-minute interval CV-P and CV-PFE counters. A value of zero indicates that the default threshold value is to be used.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

sonetPathCurrentESThreshold 1.3.6.1.4.1.4515.1.6.3.2.1.2.1.3
The trap threshold value for the interface's current 15-minute interval ES-P and ES-PFE counters. A value of zero indicates that the default threshold value is to be used.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

sonetPathCurrentSESThreshold 1.3.6.1.4.1.4515.1.6.3.2.1.2.1.4
The trap threshold value for the interface's current 15-minute interval SES-P and SES-PFE counters. A value of zero indicates that the default threshold value is to be used.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

sonetPathCurrentUASThreshold 1.3.6.1.4.1.4515.1.6.3.2.1.2.1.5
The trap threshold value for the interface's current 15-minute interval UAS-P and UAS-PFE counters. A value of zero indicates that the default threshold value is to be used.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

sonetPathDayCVThreshold 1.3.6.1.4.1.4515.1.6.3.2.1.2.1.6
The trap threshold value for the interface's current 1-day CV-P and CV-PFE counters. A value of zero indicates that the default threshold value is to be used.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

sonetPathDayESThreshold 1.3.6.1.4.1.4515.1.6.3.2.1.2.1.7
The trap threshold value for the interface's current 1-day ES-P and ES-PFE counters. A value of zero indicates that the default threshold value is to be used.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

sonetPathDaySESThreshold 1.3.6.1.4.1.4515.1.6.3.2.1.2.1.8
The trap threshold value for the interface's current 1-day SES-P and SES-PFE counters. A value of zero indicates that the default threshold value is to be used.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

sonetPathDayUASThreshold 1.3.6.1.4.1.4515.1.6.3.2.1.2.1.9
The trap threshold value for the interface's current 1-day UAS-P and UAS-PFE counters. A value of zero indicates that the default threshold value is to be used.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

sonetPathDayTable 1.3.6.1.4.1.4515.1.6.3.2.1.17
The SONET Path Day table. Contains performance statistics collected by each SONET Path over multiple 1-day intervals of operation.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SonetPathDayEntry

sonetPathDayEntry 1.3.6.1.4.1.4515.1.6.3.2.1.17.1
An entry in the SONET Path Day table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SonetPathDayEntry  

sonetPathDayNumber 1.3.6.1.4.1.4515.1.6.3.2.1.17.1.1
A number which identifies the 1-day interval for which the set of near-end path related statistics is available. The number is between 1 and n, where n is the number of 1-day intervals supported by the agent. The interval identified by 1 is the current 1-day interval, 2 is the previous (most recently completed) 1-day interval and n is the least recently completed 1-day interval.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..33  

sonetPathDayStartTime 1.3.6.1.4.1.4515.1.6.3.2.1.17.1.2
This variable indicates the date and time at which the 1-day interval of measurements began on this interface.
Status: current Access: read-only
OBJECT-TYPE    
  DateAndTime  

sonetPathDayValidData 1.3.6.1.4.1.4515.1.6.3.2.1.17.1.3
This variable assumes the value true(1) if the data stored for this interval is both valid and complete. It is set to false(2) if the data stored for this interval is incomplete or otherwise invalid because (a) the data stored for this interval is for a period greater or less than 24 hours, or (b) some data is missing.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

sonetPathDayCVs 1.3.6.1.4.1.4515.1.6.3.2.1.17.1.5
The path code violation (CV-P) count is the number of BIP-8 errors which were detected at the STS-path layer interface in a previous 1-day interval. CVs for the path layer are collected using the BIP-8 in the B3 byte located in the STS-path overhead.
Status: current Access: read-only
OBJECT-TYPE    
  PerfTotalCount  

sonetPathDayESs 1.3.6.1.4.1.4515.1.6.3.2.1.17.1.6
The path errored second (ES-P) count is the number of 1-second intervals containing one or more EDC error (B3 byte), or one or more AIS-P, LOP-P, TIM-P or UNEQ-P defects which were encountered by the SONET path layer interface in a previous 1-day interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfTotalCount  

sonetPathDaySESs 1.3.6.1.4.1.4515.1.6.3.2.1.17.1.9
The path severely errored second (SES-P) is a count of 1-second intervals containing sonetSevereErrorThreshold or more EDC error (B3 byte), or one or more AIS-P, LOP-P, TIM-P or UNEQ-P defects which were encountered by the SONET path layer interface in a previous 1-day interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfTotalCount  

sonetPathDayUASs 1.3.6.1.4.1.4515.1.6.3.2.1.17.1.10
The path unavailable second (UAS-P) is a count of 1-second intervals for which the SONET STS-path was unavailable during a previous 1-day interval. The SONET STS-path becomes unavailable at the onset of 10 contiguous SES-Ps. The 10 SES-Ps are included in unavailable time. Once unavailable, the SONET STS-path becomes available at the onset of 10 contiguous seconds with no SES-Ps. The 10 seconds with no SES-Ps are excluded from unavailable time.
Status: current Access: read-only
OBJECT-TYPE    
  PerfTotalCount  

sonetPathDayFCs 1.3.6.1.4.1.4515.1.6.3.2.1.17.1.11
The number path failures count during a day.
Status: current Access: read-only
OBJECT-TYPE    
  PerfTotalCount  

sonetPathDayTcaFlag 1.3.6.1.4.1.4515.1.6.3.2.1.17.1.12
TRUE if one of the counters crossed the threshold during the day.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

sonetPathDayEBs 1.3.6.1.4.1.4515.1.6.3.2.1.17.1.13
The number path blocks in which one or more bits are in error counted during a day.
Status: current Access: read-only
OBJECT-TYPE    
  PerfTotalCount  

sonetPathDayReset 1.3.6.1.4.1.4515.1.6.3.2.1.17.1.14
Writing this object reset the PM counters of this interval.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

sonetFarEndPathDayTable 1.3.6.1.4.1.4515.1.6.3.2.2.3
The SONET Far End Path Day table. Contains various statistics collected by each SONET Far End Path over multiple 1-day intervals of operation.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SonetFarEndPathDayEntry

sonetFarEndPathDayEntry 1.3.6.1.4.1.4515.1.6.3.2.2.3.1
An entry in the SONET Far End Path Day table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SonetFarEndPathDayEntry  

sonetFarEndPathDayNumber 1.3.6.1.4.1.4515.1.6.3.2.2.3.1.1
A number which identifies the 1-day interval for which the set of far-end path related statistics is available. The number is between 1 and n, where n is the number of 1-day intervals supported by the agent. The interval identified by 1 is the current 1-day interval, 2 is the previous (most recently completed) 1-day interval and n is the least recently completed 1-day interval.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..4  

sonetFarEndPathDayStartTime 1.3.6.1.4.1.4515.1.6.3.2.2.3.1.2
This variable indicates the date and time at which the current interval of measurements began.
Status: current Access: read-only
OBJECT-TYPE    
  DateAndTime  

sonetFarEndPathDayValidData 1.3.6.1.4.1.4515.1.6.3.2.2.3.1.3
This variable assumes the value true(1) if the data stored for this interval is both valid and complete. It is set to false(2) if the data stored for this interval is incomplete or otherwise invalid because (a) the data stored for this interval is for a period greater or less than 24 hours, or (b) some data is missing (e.g., when a near-end defect prevents some far-end data from being collected).
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

sonetFarEndPathDayCVs 1.3.6.1.4.1.4515.1.6.3.2.2.3.1.5
The far-end path code violation (CV-PFE) count is the number of REI-Ps (bit 1-4 in G1 byte) which were detected at the SONET STS-path layer interface in a previous 1-day interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfTotalCount  

sonetFarEndPathDayESs 1.3.6.1.4.1.4515.1.6.3.2.2.3.1.6
The far-end path errored second (ES-PFE) count is the number of 1-second intervals containing one or more REDC-P, or one or more RDI-P, ERDI-P server or ERDI-P connectivity defects which were encountered by the SONET STS-path layer interface in a previous 1-day interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfTotalCount  

sonetFarEndPathDaySESs 1.3.6.1.4.1.4515.1.6.3.2.2.3.1.9
The far-end path severely errored second (SES-PFE) is a count of 1-second intervals containing sonetSevereErrorThreshold or more REDC-Ps or one or more RDI-P, ERDI-P server or ERDI-P connectivity defects which were detected by the SONET STS-path layer interface in a previous 1-day interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfTotalCount  

sonetFarEndPathDayUASs 1.3.6.1.4.1.4515.1.6.3.2.2.3.1.10
The far-end path unavailable second (UAS-PFE) is a count of 1-second intervals for which the SONET STS-path was unavailable during a previous 1-day interval. The SONET STS-path becomes unavailable at the onset of 10 contiguous SES-PFEs. The 10 SES-PFEs are included in unavailable time. Once unavailable, the SONET STS-path becomes available at the onset of 10 contiguous seconds with no SES-PFEs. The 10 seconds with no SES-PFEs are excluded from unavailable time.
Status: current Access: read-only
OBJECT-TYPE    
  PerfTotalCount  

sonetFarEndPathDayFCs 1.3.6.1.4.1.4515.1.6.3.2.2.3.1.11
The far-end path failures count.
Status: current Access: read-only
OBJECT-TYPE    
  PerfTotalCount  

sonetFarEndPathDayTcaFlag 1.3.6.1.4.1.4515.1.6.3.2.2.3.1.12
TRUE if one of the counters crossed the threshold during the day.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

sonetFarEndPathDayEBs 1.3.6.1.4.1.4515.1.6.3.2.2.3.1.13
The count of far-end path blocks in which one or more bits are in error.
Status: current Access: read-only
OBJECT-TYPE    
  PerfTotalCount  

sonetFarEndPathDayReset 1.3.6.1.4.1.4515.1.6.3.2.2.3.1.14
Writing this object reset the PM counters of this interval.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

sonetVTDefaultThresholdTable 1.3.6.1.4.1.4515.1.6.3.3.1.1
The table of default thresholds for SONET Path counters.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SonetVTDefaultThresholdEntry

sonetVTDefaultThresholdEntry 1.3.6.1.4.1.4515.1.6.3.3.1.1.1
An entry in the table of default thresholds. The table has a variable for each counter type and accumulation period combination, but uses indexes to indetify the digital signal direction and rate. The agent must provide a set of default threshold values for all rates that the NE supports. The agent may make these variables read-only.
Status: current Access: not-accessible
OBJECT-TYPE    
  SonetVTDefaultThresholdEntry  

sonetVTDefaultThresholdDirection 1.3.6.1.4.1.4515.1.6.3.3.1.1.1.1
The digital signal direction for which the default threshold values apply.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER nearEnd(1), farEnd(2)  

sonetVTDefaultThresholdRate 1.3.6.1.4.1.4515.1.6.3.3.1.1.1.2
The path digital signal rate for which the default threshold values apply.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER vt1dot5(1), vtg(2)  

sonetVTDefaultCVThreshold 1.3.6.1.4.1.4515.1.6.3.3.1.1.1.3
The default value for SONET CV-V and CV-VFE counter 15-minute interval thresholds.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..16383  

sonetVTDefaultESThreshold 1.3.6.1.4.1.4515.1.6.3.3.1.1.1.4
The default value for SONET ES-V and ES-VFE counter 15-minute interval thresholds.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..900  

sonetVTDefaultSESThreshold 1.3.6.1.4.1.4515.1.6.3.3.1.1.1.5
The default value for SONET SES-V and SES-VFE counter 15-minute interval thresholds.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..900  

sonetVTDefaultUASThreshold 1.3.6.1.4.1.4515.1.6.3.3.1.1.1.6
The default value for SONET UAS-V and UAS-VFE counter 15-minute interval thresholds.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..900  

sonetVTDefaultDayCVThreshold 1.3.6.1.4.1.4515.1.6.3.3.1.1.1.7
The default value for SONET CV-V and CV-VFE counter 1-day interval thresholds.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..1048575  

sonetVTDefaultDayESThreshold 1.3.6.1.4.1.4515.1.6.3.3.1.1.1.8
The default value for SONET ES-V and ES-VFE counter 1-day interval thresholds.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

sonetVTDefaultDaySESThreshold 1.3.6.1.4.1.4515.1.6.3.3.1.1.1.9
The default value for SONET SES-V and SES-VFE counter 1-day interval thresholds.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..4095  

sonetVTDefaultDayUASThreshold 1.3.6.1.4.1.4515.1.6.3.3.1.1.1.10
The default value for SONET UAS-V and UAS-VFE counter 1-day interval thresholds.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..4095  

sonetVTThresholdTable 1.3.6.1.4.1.4515.1.6.3.3.1.2
The table of trap threshold values for SONET Path counters.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SonetVTThresholdEntry

sonetVTThresholdEntry 1.3.6.1.4.1.4515.1.6.3.3.1.2.1
An entry in the table of SONET Path trap thresholds.
Status: current Access: not-accessible
OBJECT-TYPE    
  SonetVTThresholdEntry  

sonetVTCurrentCVThreshold 1.3.6.1.4.1.4515.1.6.3.3.1.2.1.1
The trap threshold value for the interface's current 15-minute interval CV-V and CV-VFE counters. A value of zero indicates that the default threshold value is to be used.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..900  

sonetVTCurrentESThreshold 1.3.6.1.4.1.4515.1.6.3.3.1.2.1.2
The trap threshold value for the interface's current 15-minute interval ES-V and ES-VFE counters. A value of zero indicates that the default threshold value is to be used.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..900  

sonetVTCurrentSESThreshold 1.3.6.1.4.1.4515.1.6.3.3.1.2.1.3
The trap threshold value for the interface's current 15-minute interval SES-V and SES-VFE counters. A value of zero indicates that the default threshold value is to be used.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..900  

sonetVTCurrentUASThreshold 1.3.6.1.4.1.4515.1.6.3.3.1.2.1.4
The trap threshold value for the interface's current 15-minute interval UAS-V and UAS-VFE counters. A value of zero indicates that the default threshold value is to be used.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..900  

sonetVTDayCVThreshold 1.3.6.1.4.1.4515.1.6.3.3.1.2.1.5
The trap threshold value for the interface's current 1-day CV-V and CV-VFE counters. A value of zero indicates that the default threshold value is to be used.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

sonetVTDayESThreshold 1.3.6.1.4.1.4515.1.6.3.3.1.2.1.6
The trap threshold value for the interface's current 1-day ES-V and ES-VFE counters. A value of zero indicates that the default threshold value is to be used.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

sonetVTDaySESThreshold 1.3.6.1.4.1.4515.1.6.3.3.1.2.1.7
The trap threshold value for the interface's current 1-day SES-V and SES-VFE counters. A value of zero indicates that the default threshold value is to be used.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

sonetVTDayUASThreshold 1.3.6.1.4.1.4515.1.6.3.3.1.2.1.8
The trap threshold value for the interface's current 1-day UAS-V and UAS-VFE counters. A value of zero indicates that the default threshold value is to be used.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

sonetVTDayTable 1.3.6.1.4.1.4515.1.6.3.3.1.17
The SONET Path Day table. Contains performance statistics collected by each SONET Path over multiple 1-day intervals of operation.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SonetVTDayEntry

sonetVTDayEntry 1.3.6.1.4.1.4515.1.6.3.3.1.17.1
An entry in the SONET Path Day table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SonetVTDayEntry  

sonetVTDayNumber 1.3.6.1.4.1.4515.1.6.3.3.1.17.1.1
A number which identifies the 1-day interval for which the set of near-end path related statistics is available. The number is between 1 and n, where n is the number of 1-day intervals supported by the agent. The interval identified by 1 is the current 1-day interval, 2 is the previous (most recently completed) 1-day interval and n is the least recently completed 1-day interval.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..33  

sonetVTDayStartTime 1.3.6.1.4.1.4515.1.6.3.3.1.17.1.2
This variable indicates the date and time at which the 1-day interval of measurements began on this interface.
Status: current Access: read-only
OBJECT-TYPE    
  DateAndTime  

sonetVTDayValidData 1.3.6.1.4.1.4515.1.6.3.3.1.17.1.3
This variable assumes the value true(1) if the data stored for this interval is both valid and complete. It is set to false(2) if the data stored for this interval is incomplete or otherwise invalid because (a) the data stored for this interval is for a period greater or less than 24 hours, or (b) some data is missing.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

sonetVTDayFCs 1.3.6.1.4.1.4515.1.6.3.3.1.17.1.4
The near-end path failure count (FC-V) is the number of occurences of near-end path failure events encountered by the SONET path layer interface in a previous 1-day interval. A near-end path failure event begins when the first of any of LOP-V, AIS-V or UNEQ-V failures is declared; a near-end path failure event ends when all LOP-V, AIS-V and UNEQ-V failures have cleared.
Status: current Access: read-only
OBJECT-TYPE    
  PerfTotalCount  

sonetVTDayCVs 1.3.6.1.4.1.4515.1.6.3.3.1.17.1.5
The path code violation (CV-V) count is the number of BIP-2 errors which were detected at the VT-path layer interface in a previous 1-day interval. CVs for the path layer are collected using the BIP-2 in the V5 byte located in the VT-path overhead.
Status: current Access: read-only
OBJECT-TYPE    
  PerfTotalCount  

sonetVTDayESs 1.3.6.1.4.1.4515.1.6.3.3.1.17.1.6
The path errored second (ES-V) count is the number of 1-second intervals containing one or more EDC error (V5 byte), or one or more AIS-V, LOP-V or UNEQ-V defects which were encountered by the SONET path layer interface in a previous 1-day interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfTotalCount  

sonetVTDaySESs 1.3.6.1.4.1.4515.1.6.3.3.1.17.1.7
The path severely errored second (SES-V) is a count of 1-second intervals containing sonetSevereErrorThreshold or more EDC error (V5 byte), or one or more AIS-V, LOP-V or UNEQ-V defects which were encountered by the SONET path layer interface in a previous 1-day interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfTotalCount  

sonetVTDayUASs 1.3.6.1.4.1.4515.1.6.3.3.1.17.1.8
The path unavailable second (UAS-V) is a count of 1-second intervals for which the SONET VT-path was unavailable during a previous 1-day interval. The SONET VT-path becomes unavailable at the onset of 10 contiguous SES-Vs. The 10 SES-Vs are included in unavailable time. Once unavailable, the SONET VT-path becomes available at the onset of 10 contiguous seconds with no SES-Vs. The 10 seconds with no SES-Vs are excluded from unavailable time.
Status: current Access: read-only
OBJECT-TYPE    
  PerfTotalCount  

sonetVTDayEBs 1.3.6.1.4.1.4515.1.6.3.3.1.17.1.9
The number VT path blocks in which one or more bits are in error counted during a day.
Status: current Access: read-only
OBJECT-TYPE    
  PerfTotalCount  

sonetVTDayTcaFlag 1.3.6.1.4.1.4515.1.6.3.3.1.17.1.10
TRUE if one of the counters crossed the threshold during the day.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

sonetVTDayReset 1.3.6.1.4.1.4515.1.6.3.3.1.17.1.11
Writing this object reset the PM counters of this interval.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

sonetFarEndVTDayTable 1.3.6.1.4.1.4515.1.6.3.3.2.3
The SONET Far End Path Day table. Contains various statistics collected by each SONET Far End Path over multiple 1-day intervals of operation.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SonetFarEndVTDayEntry

sonetFarEndVTDayEntry 1.3.6.1.4.1.4515.1.6.3.3.2.3.1
An entry in the SONET Far End Path Day table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SonetFarEndVTDayEntry  

sonetFarEndVTDayNumber 1.3.6.1.4.1.4515.1.6.3.3.2.3.1.1
A number which identifies the 1-day interval for which the set of far-end VT-path related statistics is available. The number is between 1 and n, where n is the number of 1-day intervals supported by the agent. The interval identified by 1 is the current 1-day interval, 2 is the previous (most recently completed) 1-day interval and n is the least recently completed 1-day interval.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..4  

sonetFarEndVTDayStartTime 1.3.6.1.4.1.4515.1.6.3.3.2.3.1.2
This variable indicates the date and time at which the current interval of measurements began.
Status: current Access: read-only
OBJECT-TYPE    
  DateAndTime  

sonetFarEndVTDayValidData 1.3.6.1.4.1.4515.1.6.3.3.2.3.1.3
This variable assumes the value true(1) if the data stored for this interval is both valid and complete. It is set to false(2) if the data stored for this interval is incomplete or otherwise invalid because (a) the data stored for this interval is for a period greater or less than 24 hours, or (b) some data is missing (e.g., when a near-end defect prevents some far-end data from being collected).
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

sonetFarEndVTDayFCs 1.3.6.1.4.1.4515.1.6.3.3.2.3.1.4
The far-end path failure count (FC-VFE) is the number of occurences of far-end path failure events detected by the SONET VT-path layer interface in a previous 1-day interval. A far-end path failure event begins when the first of any remote failure indication (RFI-V, RFI-V server, or RFI-V connectivity) failure is declared; a far-end path failure event ends when all RFI-V, RFI-V server, or RFI-V connectivity failures are cleared.
Status: current Access: read-only
OBJECT-TYPE    
  PerfTotalCount  

sonetFarEndVTDayCVs 1.3.6.1.4.1.4515.1.6.3.3.2.3.1.5
The far-end path code violation (CV-VFE) count is the number of REI-Vs (bit 1-4 in G1 byte) which were detected at the SONET VT-path layer interface in a previous 1-day interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfTotalCount  

sonetFarEndVTDayESs 1.3.6.1.4.1.4515.1.6.3.3.2.3.1.6
The far-end path errored second (ES-VFE) count is the number of 1-second intervals containing one or more REDC-V, or one or more RDI-V, ERDI-V server or ERDI-V connectivity defects which were encountered by the SONET VT-path layer interface in a previous 1-day interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfTotalCount  

sonetFarEndVTDaySESs 1.3.6.1.4.1.4515.1.6.3.3.2.3.1.7
The far-end path severely errored second (SES-VFE) is a count of 1-second intervals containing sonetSevereErrorThreshold or more REDC-Vs or one or more RDI-V, ERDI-V server or ERDI-V connectivity defects which were detected by the SONET VT-path layer interface in a previous 1-day interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfTotalCount  

sonetFarEndVTDayUASs 1.3.6.1.4.1.4515.1.6.3.3.2.3.1.8
The far-end path unavailable second (UAS-VFE) is a count of 1-second intervals for which the SONET VT-path was unavailable during a previous 1-day interval. The SONET VT-path becomes unavailable at the onset of 10 contiguous SES-VFEs. The 10 SES-VFEs are included in unavailable time. Once unavailable, the SONET VT-path becomes available at the onset of 10 contiguous seconds with no SES-VFEs. The 10 seconds with no SES-VFEs are excluded from unavailable time.
Status: current Access: read-only
OBJECT-TYPE    
  PerfTotalCount  

sonetFarEndVTDayEBs 1.3.6.1.4.1.4515.1.6.3.3.2.3.1.9
The number VT path blocks in which one or more bits are in error counted during a day detected by the Far End.
Status: current Access: read-only
OBJECT-TYPE    
  PerfTotalCount  

sonetFarEndVTDayTcaFlag 1.3.6.1.4.1.4515.1.6.3.3.2.3.1.10
TRUE if one of the counters crossed the threshold during the day.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

sonetFarEndVTDayReset 1.3.6.1.4.1.4515.1.6.3.3.2.3.1.11
Writing this object reset the PM counters of this interval.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

sonetTrap 1.3.6.1.4.1.4515.1.6.3.1.6
OBJECT IDENTIFIER    

sonetCounterId 1.3.6.1.4.1.4515.1.6.3.1.6.1
The OBJECT IDENTIFIER of the instance of the SONET counter that has crossed its threshold.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  OBJECT IDENTIFIER  

sonetCounterValue 1.3.6.1.4.1.4515.1.6.3.1.6.2
The current value of the SONET counter that has crossed its threshold.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

sonetThresholdCrossing 1.3.6.1.4.1.4515.1.6.3.1.6.3
This notification signifies that a counter has crossed its designated threshold. The term 'threshold crossing' means that a threshold has been reached or exceeded. A threshold crossing alert message (trap) signifies a performance degredation at or above the preset threshold value.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE