SK-GE-MIB

File: SK-GE-MIB.mib (58828 bytes)

Imported modules

RFC1155-SMI RFC1213-MIB RFC-1215

Imported symbols

enterprises OBJECT-TYPE Counter
TimeTicks NetworkAddress DisplayString
TRAP-TYPE

Defined Types

SkGeMACAddress  
OCTET STRING Size(6)    

SkGeEntry  
SEQUENCE    
  skGeIndex INTEGER
  skGeIfIndex INTEGER
  skGePortNumber INTEGER
  skGeDeviceType OBJECT IDENTIFIER
  skGeDriverDescr DisplayString
  skGeDriverVersion DisplayString
  skGeHwDescr DisplayString
  skGeHwVersion DisplayString
  skGeChipSet OBJECT IDENTIFIER
  skGeDeviceAction INTEGER
  skGeTestResult INTEGER
  skGeBusType INTEGER
  skGeBusSpeed INTEGER
  skGeBusWidth INTEGER

SkGeChecksumEntry  
SEQUENCE    
  skGeChecksumGeIndex INTEGER
  skGeChecksumIndex INTEGER
  skGeChecksumRxOkCts Counter
  skGeChecksumRxUnableCts Counter
  skGeChecksumRxErrCts Counter
  skGeChecksumTxOkCts Counter
  skGeChecksumTxUnableCts Counter

SkTrapDestEntry  
SEQUENCE    
  skGeTrapDestIndex INTEGER
  skGeTrapDestAddress NetworkAddress

SkGeSensorEntry  
SEQUENCE    
  skGeSensorGeIndex INTEGER
  skGeSensorIndex INTEGER
  skGeSensorDescr DisplayString
  skGeSensorType INTEGER
  skGeSensorValue INTEGER
  skGeSensorWarningThresholdLow INTEGER
  skGeSensorWarningThresholdHigh INTEGER
  skGeSensorErrorThresholdLow INTEGER
  skGeSensorErrorThresholdHigh INTEGER
  skGeSensorStatus INTEGER
  skGeSensorWarningCts Counter
  skGeSensorErrorCts Counter
  skGeSensorWarningTimeStamp TimeTicks
  skGeSensorErrorTimeStamp TimeTicks

SkGeStatEntry  
SEQUENCE    
  skGeStatGeIndex INTEGER
  skGeStatIndex INTEGER
  skGeStatTxOkCts Counter
  skGeStatTxOctetsHighOkCts Counter
  skGeStatTxOctetsLowOkCts Counter
  skGeStatTxBroadcastOkCts Counter
  skGeStatTxMulticastOkCts Counter
  skGeStatTxUnicastOkCts Counter
  skGeStatTxLongFramesCts Counter
  skGeStatTxBurstCts Counter
  skGeStatTxPFlowCtrlCts Counter
  skGeStatTxFlowCtrlCts Counter
  skGeStatTxSingleCollisionsCts Counter
  skGeStatTxMultipleCollisionsCts Counter
  skGeStatTxExcessiveCollisionsCts Counter
  skGeStatTxLateCollisionsCts Counter
  skGeStatTxDeferralCts Counter
  skGeStatTxExcessiveDeferralCts Counter
  skGeStatTxFifoUnderrunCts Counter
  skGeStatTxCarrierSenseCts Counter
  skGeStatTxOctets64Cts Counter
  skGeStatTxOctets127Cts Counter
  skGeStatTxOctets255Cts Counter
  skGeStatTxOctets511Cts Counter
  skGeStatTxOctets1023Cts Counter
  skGeStatTxOctetsMaxCts Counter
  skGeStatTxSyncCts Counter
  skGeStatTxSyncOctetsHighCts Counter
  skGeStatTxSyncOctetsLowCts Counter
  skGeStatRxOkCts Counter
  skGeStatRxOctetsHighOkCts Counter
  skGeStatRxOctetsLowOkCts Counter
  skGeStatRxBroadcastOkCts Counter
  skGeStatRxMulticastOkCts Counter
  skGeStatRxUnicastOkCts Counter
  skGeStatRxPFlowCtrlCts Counter
  skGeStatRxFlowCtrlCts Counter
  skGeStatRxPFlowCtrlErrCts Counter
  skGeStatRxFlowCtrlUnknownCts Counter
  skGeStatRxBurstCts Counter
  skGeStatRxMissedCts Counter
  skGeStatRxFramingCts Counter
  skGeStatRxFifoOverflowCts Counter
  skGeStatRxJabberCts Counter
  skGeStatRxCarrierCts Counter
  skGeStatRxIRLengthCts Counter
  skGeStatRxSymbolCts Counter
  skGeStatRxShortsCts Counter
  skGeStatRxRuntCts Counter
  skGeStatRxCextCts Counter
  skGeStatRxTooLongCts Counter
  skGeStatRxFCSCts Counter
  skGeStatRxOctets64Cts Counter
  skGeStatRxOctets127Cts Counter
  skGeStatRxOctets255Cts Counter
  skGeStatRxOctets511Cts Counter
  skGeStatRxOctets1023Cts Counter
  skGeStatRxOctetsMaxCts Counter
  skGeStatRxLongFramesCts Counter

SkGeConfEntry  
SEQUENCE    
  skGeConfGeIndex INTEGER
  skGeConfIndex INTEGER
  skGeConfPhysCurrentAddr SkGeMACAddress
  skGeConfPhysFactoryAddr SkGeMACAddress
  skGeConfPMDType INTEGER
  skGeConfConnector INTEGER
  skGeConfLinkCap INTEGER
  skGeConfLinkMode INTEGER
  skGeConfLinkModeStatus INTEGER
  skGeConfLinkStatus INTEGER
  skGeConfFlowCtrlCap INTEGER
  skGeConfFlowCtrlMode INTEGER
  skGeConfFlowCtrlStatus INTEGER
  skGeConfPhyOperationCap INTEGER
  skGeConfPhyOperationMode INTEGER
  skGeConfPhyOperationStatus INTEGER

SkGeVpdEntry  
SEQUENCE    
  skGeVpdIndex INTEGER
  skGeVpdFreeBytes INTEGER
  skGeVpdEntryList DisplayString

SkGeVpdValueEntry  
SEQUENCE    
  skGeVpdValueIndex INTEGER
  skGeVpdKey DisplayString
  skGeVpdValue OCTET STRING
  skGeVpdAccess INTEGER
  skGeVpdValid INTEGER

SkGeRlmtEntry  
SEQUENCE    
  skGeRlmtIndex INTEGER
  skGeRlmtMode INTEGER
  skGeRlmtPortActive INTEGER
  skGeRlmtPortPreferred INTEGER
  skGeRlmtChangeCts Counter
  skGeRlmtChangeTimeStamp TimeTicks
  skGeRlmtChangeEstimate INTEGER
  skGeRlmtChangeThreshold INTEGER
  skGeRlmtPortNumber INTEGER

SkGeRlmtStatEntry  
SEQUENCE    
  skGeRlmtStatGeIndex INTEGER
  skGeRlmtStatIndex INTEGER
  skGeRlmtStatStatus INTEGER
  skGeRlmtStatTxHelloCts Counter
  skGeRlmtStatRxHelloCts Counter
  skGeRlmtStatTxSpHelloReqCts Counter
  skGeRlmtStatRxSpHelloCts Counter

SkGeRlmtMonitorEntry  
SEQUENCE    
  skGeRlmtMonitorGeIndex INTEGER
  skGeRlmtMonitorIndex INTEGER
  skGeRlmtMonitorAddr SkGeMACAddress
  skGeRlmtMonitorErrCts INTEGER
  skGeRlmtMonitorTimeStamp TimeTicks
  skGeRlmtMonitorAdmin INTEGER

Defined Values

sk 1.3.6.1.4.1.179
OBJECT IDENTIFIER    

skSystems 1.3.6.1.4.1.179.1
OBJECT IDENTIFIER    

skMibs 1.3.6.1.4.1.179.2
OBJECT IDENTIFIER    

skNICs 1.3.6.1.4.1.179.3
OBJECT IDENTIFIER    

skChipSets 1.3.6.1.4.1.179.4
OBJECT IDENTIFIER    

skConcMib 1.3.6.1.4.1.179.2.3
OBJECT IDENTIFIER    

skfddiMib 1.3.6.1.4.1.179.2.4
OBJECT IDENTIFIER    

skGeMib 1.3.6.1.4.1.179.2.5
OBJECT IDENTIFIER    

skFddiNICs 1.3.6.1.4.1.179.3.1
OBJECT IDENTIFIER    

skGeNICs 1.3.6.1.4.1.179.3.2
OBJECT IDENTIFIER    

skGeXMAC11800FP 1.3.6.1.4.1.179.4.1
OBJECT IDENTIFIER    









skGeGeneral 1.3.6.1.4.1.179.2.5.1
OBJECT IDENTIFIER    

skGeVpd 1.3.6.1.4.1.179.2.5.2
OBJECT IDENTIFIER    

skGeRlmt 1.3.6.1.4.1.179.2.5.3
OBJECT IDENTIFIER    

skGeMibVersion 1.3.6.1.4.1.179.2.5.1.1
The version of this MIB (e.g. v1.0).
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

skGeAction 1.3.6.1.4.1.179.2.5.1.2
Returns on query 'idle'. A set to 'idle' does nothing. A set to 'force-trap' transmits the trap specified in skGeTrapForceType. 'save-permanent' saves the setable values of this MIB permanently.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER idle(1), force-trap(2), save-permanent(3)  

skGeNumber 1.3.6.1.4.1.179.2.5.1.3
The number of Gigabit-Ethernet adapters.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

skGeTable 1.3.6.1.4.1.179.2.5.1.4
Table for general adapter specific information.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SkGeEntry

skGeEntry 1.3.6.1.4.1.179.2.5.1.4.1
Entry of skGeTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SkGeEntry  

skGeIndex 1.3.6.1.4.1.179.2.5.1.4.1.1
Adapter index (1..n).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

skGeIfIndex 1.3.6.1.4.1.179.2.5.1.4.1.2
Stores the corresponding ifIndex of the mib-2 interfaces table. If the value cannot be obtained a '0' is stored.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

skGePortNumber 1.3.6.1.4.1.179.2.5.1.4.1.3
Number of ports per adapter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

skGeDeviceType 1.3.6.1.4.1.179.2.5.1.4.1.4
Returns the object identifier of the NIC. If it is unknown 0.0 is returned.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

skGeDriverDescr 1.3.6.1.4.1.179.2.5.1.4.1.5
A description of the driver (e.g. sk98win - Miniport Gigabit-Ethernet driver).
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

skGeDriverVersion 1.3.6.1.4.1.179.2.5.1.4.1.6
The driver version (e.g. v1.05 beta).
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

skGeHwDescr 1.3.6.1.4.1.179.2.5.1.4.1.7
A description of the device hardware (e.g. SK-NET Genesis Sx Single Port).
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

skGeHwVersion 1.3.6.1.4.1.179.2.5.1.4.1.8
The device hardware version. (e.g. v1.2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

skGeChipSet 1.3.6.1.4.1.179.2.5.1.4.1.9
Stores the object identifier of the used chip-set.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

skGeDeviceAction 1.3.6.1.4.1.179.2.5.1.4.1.10
A set to this variable performs a specific action. A get-request to this variable always returns the idle (1) value. The result of the self-test is stored in skGeTestResult.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER idle(1), reset(2), self-test(3), reset-counters(4)  

skGeTestResult 1.3.6.1.4.1.179.2.5.1.4.1.11
Stores the self test result, which was initiated by skGeDeviceAction. The value is a sum and 2 raised the power of the result is added to the sum. A sum of zero indicates a successful self-test. Result Power unkown 0 (Initial value) tranceiverErr 1 asicErr 2 sensorErr 3 powermgmtErr 4 pciErr 5 macErr 6
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

skGeBusType 1.3.6.1.4.1.179.2.5.1.4.1.12
Returns the bus type.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER pci(1)  

skGeBusSpeed 1.3.6.1.4.1.179.2.5.1.4.1.13
Returns the bus speed in MHz (e.g. 33 means a bus speed of 33 MHz). If the value is unknown a 0 is returned.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

skGeBusWidth 1.3.6.1.4.1.179.2.5.1.4.1.14
Returns the bus width in bits (e.g. 64 means a bus width of 64 bit). If the value is unknown a 0 is returned.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

skGeChecksumEntriesNumber 1.3.6.1.4.1.179.2.5.1.5
Number of entries in skGeCheckSumTable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

skGeChecksumTable 1.3.6.1.4.1.179.2.5.1.6
Table of the adapter hardware checksumming module.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SkGeChecksumEntry

skGeChecksumEntry 1.3.6.1.4.1.179.2.5.1.6.1
Entry of the checksum table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SkGeChecksumEntry  

skGeChecksumGeIndex 1.3.6.1.4.1.179.2.5.1.6.1.1
Index of the adapter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

skGeChecksumIndex 1.3.6.1.4.1.179.2.5.1.6.1.2
Index of the protocol. The indexes have fixed semantics.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ip(1), udp(2), tcp(3)  

skGeChecksumRxOkCts 1.3.6.1.4.1.179.2.5.1.6.1.3
Number of received frames for which the protocol checksum verification was successfully performed in hardware.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeChecksumRxUnableCts 1.3.6.1.4.1.179.2.5.1.6.1.4
Number of received frames for which the protocol checksum verification was left to the protocol.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeChecksumRxErrCts 1.3.6.1.4.1.179.2.5.1.6.1.5
Number of received frames for which the protocol checksum verification in hardware found an error.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeChecksumTxOkCts 1.3.6.1.4.1.179.2.5.1.6.1.6
Number of transmitted packets for which the protocol checksum was generated in hardware.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeChecksumTxUnableCts 1.3.6.1.4.1.179.2.5.1.6.1.7
Number of packets, which could not be sent because the requested generation of the checksum was not possible.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeTrapForceType 1.3.6.1.4.1.179.2.5.1.7
Stores the trap number and the value list that is to be transmitted. The transmission is initiated with skGeAction (force-trap). Each field in the octet string consists of a one octet length field followed by the value.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

skGeTrapDestEntriesNumber 1.3.6.1.4.1.179.2.5.1.8
Number of entries in skGeTrapDestTable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

skGeTrapDestTable 1.3.6.1.4.1.179.2.5.1.9
Table of trap destination addresses to which the agent will send traps.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SkTrapDestEntry

skGeTrapDestEntry 1.3.6.1.4.1.179.2.5.1.9.1
Entry of trap destination table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SkTrapDestEntry  

skGeTrapDestIndex 1.3.6.1.4.1.179.2.5.1.9.1.1
Index of the trap destination table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

skGeTrapDestAddress 1.3.6.1.4.1.179.2.5.1.9.1.2
The destination address to which the agent sends its trap PDUs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  NetworkAddress  

skGeTrapFilter 1.3.6.1.4.1.179.2.5.1.10
The trap filter bits are stored as a sum of powers of 2 (a bit string) in this variable. If the bit is set to 0 the corresponding trap will not be transmitted. If the bit is set to 1 trap transmission is enabled. Trap Power skGeSensorWarningLower 0 skGeSensorWarningUpper 1 skGeSensorErrorLower 2 skGeSensorErrorUpper 3 skGeRlmtChangeThresholdCondition 4 skGeRlmtChangeCondition 5 skGeRlmtPortDown 6 skGeRlmtPortUp 7 skGeRlmtSegmentation 8
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

skGeSensorEntriesNumber 1.3.6.1.4.1.179.2.5.1.13
Number of entries in skGeSensorTable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

skGeSensorTable 1.3.6.1.4.1.179.2.5.1.14
Table for sensor related values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SkGeSensorEntry

skGeSensorEntry 1.3.6.1.4.1.179.2.5.1.14.1
Entry of sensor table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SkGeSensorEntry  

skGeSensorGeIndex 1.3.6.1.4.1.179.2.5.1.14.1.1
Adapter index which corresponds with skGeIndex.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

skGeSensorIndex 1.3.6.1.4.1.179.2.5.1.14.1.2
Index of the sensor. The indexes have fixed semantics.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER temperature(1), voltage-pci(2), voltage-pci-io(3), voltage-asic(4), voltage-pma-or-phy-a-pll(5), voltage-phy-2v5(6), voltage-phy-b-pll(7), speed-fan(8)  

skGeSensorDescr 1.3.6.1.4.1.179.2.5.1.14.1.3
A textual description of the sensor.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

skGeSensorType 1.3.6.1.4.1.179.2.5.1.14.1.4
Stores the sensor type.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER temperature(1), voltage(2), rpm(3)  

skGeSensorValue 1.3.6.1.4.1.179.2.5.1.14.1.5
Stores the current value of the sensor in 10th of degree celsius, milli volts or round per minutes (rpm).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

skGeSensorWarningThresholdLow 1.3.6.1.4.1.179.2.5.1.14.1.6
Stores the lower warning threshold of the allowed value range for the monitored unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

skGeSensorWarningThresholdHigh 1.3.6.1.4.1.179.2.5.1.14.1.7
Stores the upper warning threshold of the allowed value range for the monitored unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

skGeSensorErrorThresholdLow 1.3.6.1.4.1.179.2.5.1.14.1.8
Stores the lower threshold of the allowed value range for the monitored unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

skGeSensorErrorThresholdHigh 1.3.6.1.4.1.179.2.5.1.14.1.9
Stores the upper threshold of the allowed value range for the monitored unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

skGeSensorStatus 1.3.6.1.4.1.179.2.5.1.14.1.10
If a threshold is exceeded this flag will be set.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), warning(2), error(3)  

skGeSensorWarningCts 1.3.6.1.4.1.179.2.5.1.14.1.11
If a warning threshold is exceeded this counter will be incremented and a trap will be generated. If the sensor value exceeds the threshold permanently this counter is incremented every two seconds and a trap is generated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeSensorErrorCts 1.3.6.1.4.1.179.2.5.1.14.1.12
If a threshold is exceeded this counter will be incremented and a trap will be generated. If the sensor value exceeds the threshold permanently this counter is incremented every second and a trap is generated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeSensorWarningTimeStamp 1.3.6.1.4.1.179.2.5.1.14.1.13
Stores the time since the last reboot in hundreds of seconds of the last warning threshold exceed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

skGeSensorErrorTimeStamp 1.3.6.1.4.1.179.2.5.1.14.1.14
Stores the time since the last reboot in hundreds of seconds of the last error threshold exceed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

skGeStatEntriesNumber 1.3.6.1.4.1.179.2.5.1.15
Number of entries in the skGeStatTable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

skGeStatTable 1.3.6.1.4.1.179.2.5.1.16
Statistical data of the ports. The number of table entries is stored in skGeStatEntriesNumber.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SkGeStatEntry

skGeStatEntry 1.3.6.1.4.1.179.2.5.1.16.1
The first entry (skGeStatIndex) of each adapter card (skGeStatGeIndex) is a virtual one and represents the currently active port with settled statistical data. This means that the number of port specific statistical data entries in this table is by one element higher than the physically provided port number (skGePortNumber).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SkGeStatEntry  

skGeStatGeIndex 1.3.6.1.4.1.179.2.5.1.16.1.1
Adapter index which corresponds with skGeIndex.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

skGeStatIndex 1.3.6.1.4.1.179.2.5.1.16.1.2
The port index. The first index denotes the virtual port entry, which contains settled statistical data. The ports are enumerated from 1..n.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

skGeStatTxOkCts 1.3.6.1.4.1.179.2.5.1.16.1.3
A count of frames (including short frames, broadcasts frames, and multicast frames) that are successfully transmitted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeStatTxOctetsHighOkCts 1.3.6.1.4.1.179.2.5.1.16.1.4
The upper 32 bit count of data and padding octets of frames that are successfully transmitted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeStatTxOctetsLowOkCts 1.3.6.1.4.1.179.2.5.1.16.1.5
The lower 32 bit count of data and padding octets of frames that are successfully transmitted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeStatTxBroadcastOkCts 1.3.6.1.4.1.179.2.5.1.16.1.6
A count of frames that were successfully transmitted to the broadcast address. Frames transmitted to multicast addresses are not broadcast frames and are excluded.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeStatTxMulticastOkCts 1.3.6.1.4.1.179.2.5.1.16.1.7
A count of frames that were successfully transmitted to a group destination address other than broadcast.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeStatTxUnicastOkCts 1.3.6.1.4.1.179.2.5.1.16.1.8
The total number of frames transmitted that were directed to an unicast address. This number does not include frames directed to broadcast or multicast addresses.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeStatTxLongFramesCts 1.3.6.1.4.1.179.2.5.1.16.1.9
The total number of frames transmitted that are more than the IEEE 802.3 maximum frame size. Typically, 1518 octets if neither the OneLevelVLAN nor TwoLevelVLAN is active, the long frames are defined as more than 1522 octets (excluding framing bits but including FCS octets). If the TowLevelVLAN is active, then long frames are defined as more than 1538 octets (excluding framing bits but including FCS octets).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeStatTxBurstCts 1.3.6.1.4.1.179.2.5.1.16.1.10
The total number of burst events.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeStatTxPFlowCtrlCts 1.3.6.1.4.1.179.2.5.1.16.1.11
The total number of Pause Flow-Control frames transmitted, of Opcode=0001.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeStatTxFlowCtrlCts 1.3.6.1.4.1.179.2.5.1.16.1.12
A count of Flow Control frames transmitted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeStatTxSingleCollisionsCts 1.3.6.1.4.1.179.2.5.1.16.1.13
A count of successfully transmitted frames for which transmission is inhibited by exactly one collision.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeStatTxMultipleCollisionsCts 1.3.6.1.4.1.179.2.5.1.16.1.14
A count of successfully transmitted frames for which transmission is inhibited by more than one collision.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeStatTxExcessiveCollisionsCts 1.3.6.1.4.1.179.2.5.1.16.1.15
A count of frames that due to excessive collisions are not transmitted successfully.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeStatTxLateCollisionsCts 1.3.6.1.4.1.179.2.5.1.16.1.16
A count of the times that a collision has been detected later than one slot time, from the start of the packet transmission. A late collision is counted twice, i.e., both as a collision and as a lateCollision.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeStatTxDeferralCts 1.3.6.1.4.1.179.2.5.1.16.1.17
A count of frames whose transmission was delayed on its first attempt because the medium was busy.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeStatTxExcessiveDeferralCts 1.3.6.1.4.1.179.2.5.1.16.1.18
A count of frames that deferred for an excessive period of time. This counter may only be incremented once per LLC transmission.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeStatTxFifoUnderrunCts 1.3.6.1.4.1.179.2.5.1.16.1.19
The number of transmit FIFO underrun events.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeStatTxCarrierSenseCts 1.3.6.1.4.1.179.2.5.1.16.1.20
A count of times that the carrier sense condition was not asserted or was deasserted during the transmission of a frame without collision.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeStatTxOctets64Cts 1.3.6.1.4.1.179.2.5.1.16.1.22
The total number of frames transmitted that were 64 octets in length (excluding framing bits but including FCS octets).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeStatTxOctets127Cts 1.3.6.1.4.1.179.2.5.1.16.1.23
The total number of frames transmitted that were between 65 and 127 octets in length inclusive (excluding framing bits but including FCS octets).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeStatTxOctets255Cts 1.3.6.1.4.1.179.2.5.1.16.1.24
The total number of frames transmitted that were between 128 and 255 octets in length inclusive (excluding framing bits but including FCS octets).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeStatTxOctets511Cts 1.3.6.1.4.1.179.2.5.1.16.1.25
The total number of frames transmitted that were between 256 and 511 octets in length inclusive (excluding framing bits but including FCS octets).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeStatTxOctets1023Cts 1.3.6.1.4.1.179.2.5.1.16.1.26
The total number of frames transmitted that were between 512 and 1023 octets in length inclusive (excluding framing bits but including FCS octets).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeStatTxOctetsMaxCts 1.3.6.1.4.1.179.2.5.1.16.1.27
The total number of frames transmitted that were between 1024 and 1518 octets in length inclusive (excluding framing bits but including FCS octets). If the OneLevelVLAN is active this statistic counts frames that are between 1024 and 1522 octets (excluding framing bits but including FCS octets). If the TwoLevelVLAN is active, this statistic counts the frames that are between 1024 and 1538 octets (excluding framing bits but including FCS octets).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeStatTxSyncCts 1.3.6.1.4.1.179.2.5.1.16.1.28
The total number of frames transmitted synchronuously.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeStatTxSyncOctetsHighCts 1.3.6.1.4.1.179.2.5.1.16.1.29
The upper 32 bit count of synchronuously transmitted octets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeStatTxSyncOctetsLowCts 1.3.6.1.4.1.179.2.5.1.16.1.30
The lower 32 bit count of synchronuously transmitted octets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeStatRxOkCts 1.3.6.1.4.1.179.2.5.1.16.1.31
A count of frames (including short frames, broadcast frames, and multicast frames) that are successfully received.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeStatRxOctetsHighOkCts 1.3.6.1.4.1.179.2.5.1.16.1.32
The upper 32 bit count of data and padding octets in frames that are successfully received. This does not include octets in frames received with frame-too-long, FCS, length or alignment errors, or frames lost due to internal MAC sub-layer error.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeStatRxOctetsLowOkCts 1.3.6.1.4.1.179.2.5.1.16.1.33
The lower 32 bit count of data and padding octets in frames that are successfully received. This does not include octets in frames received with frame-too-long, FCS, length or alignment errors, or frames lost due to internal MAC sub-layer error.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeStatRxBroadcastOkCts 1.3.6.1.4.1.179.2.5.1.16.1.34
A count of frames that are successfully received and are directed to the broadcast group address. This does not include frames received with frame-too-long, FCS, length or alignment errors, or frames lost due to internal MAC sub-layer error.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeStatRxMulticastOkCts 1.3.6.1.4.1.179.2.5.1.16.1.35
A count of frames that are successfully received and are directed to an active non-broadcast group address. This does not include frames received with frame-too- long, FCS, length or alignment errors, or frames lost due to internal MAC sub-layer error.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeStatRxUnicastOkCts 1.3.6.1.4.1.179.2.5.1.16.1.36
The total number of good frames received that were directed to any unicast address, as defined by the Counter Exact Address Match Criteria.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeStatRxPFlowCtrlCts 1.3.6.1.4.1.179.2.5.1.16.1.37
A count of Flow Control frames received with a length- or-type field value equal to the reserved type for 802.3_MAC_Control and an opcode indicating a PAUSE operation.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeStatRxFlowCtrlCts 1.3.6.1.4.1.179.2.5.1.16.1.38
A count of Flow Control frames received. Flow Control frames are defined as valid frames with a length-or-type field value equal to the reserved type for 802.3_MAC_Control.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeStatRxPFlowCtrlErrCts 1.3.6.1.4.1.179.2.5.1.16.1.39
A count of Flow Control frames received with standard PAUSE address with a length-or-type field value equal to the reserved type for 802.3_MAC_Control, but without a valid PAUSE Opcode (0001).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeStatRxFlowCtrlUnknownCts 1.3.6.1.4.1.179.2.5.1.16.1.40
A count of Flow Control frames received that contain an opcode that is not supported by the device. Flow Control frames are defined as valid frames with a length-or-type field value equal to the reserved type for 802.3_MAC_Control and with an opcode for a function that is not supported by the device.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeStatRxBurstCts 1.3.6.1.4.1.179.2.5.1.16.1.41
The total number of burst events.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeStatRxMissedCts 1.3.6.1.4.1.179.2.5.1.16.1.42
The total number of events in which frames were missed by the controller due to buffer overflow.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeStatRxFramingCts 1.3.6.1.4.1.179.2.5.1.16.1.43
The total number of frames received with improper end- of-frame delimiter
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeStatRxFifoOverflowCts 1.3.6.1.4.1.179.2.5.1.16.1.44
The number of receive FIFO overflow events.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeStatRxJabberCts 1.3.6.1.4.1.179.2.5.1.16.1.45
The total number of frames received that were longer than 1518 octets (excluding framing bits but including FCS octets), and had a bad FCS with an integral number of octets; 1522 octets if OneLevelVLAN is active; 1538 octets if TwoLeveVLAN is active.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeStatRxCarrierCts 1.3.6.1.4.1.179.2.5.1.16.1.46
An event counter for the number of times the carrier event is longer than the permissible duration.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeStatRxIRLengthCts 1.3.6.1.4.1.179.2.5.1.16.1.47
A count of frames with a length-or-type field value between the minimum unpadded LLC MAC client data size and the maximum allowed LLC MAC client data size inclusive, that does not match the number of LLC MAC client data octets received. The counter also contains frames with a length-or-type field value less than the minimum unpadded LLC MAC client data size. Note: this error is not generated if length field is between 1 and 45 (as this becomes padding case).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeStatRxSymbolCts 1.3.6.1.4.1.179.2.5.1.16.1.48
A count of the number of times the receiving media is non-idle (a carrier event) for a period of time greater than or equal to slot-time for half-duplex operation, or greater than or equal to min-frame-size for full-duplex operation, and during which there was at least one occurrence of an event that causes the PHY to indicate 'Data reception error' on the GMII.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeStatRxShortsCts 1.3.6.1.4.1.179.2.5.1.16.1.49
An event counter by one for each carrier event with activity-duration less than short-event-max-time. In the 1000 Mb/s case short-event-max-time is 72 bits (9 octets).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeStatRxRuntCts 1.3.6.1.4.1.179.2.5.1.16.1.50
A counter for each carrier-event that the octet count is less than 64.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeStatRxCextCts 1.3.6.1.4.1.179.2.5.1.16.1.51
A counter of received frames with no collision, short, or framing error in which the carrier extension was inadequate.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeStatRxTooLongCts 1.3.6.1.4.1.179.2.5.1.16.1.52
A count of frames received that exceed the maximum permitted frame size, i.e., 1518 octets (excluding framing bits, but including FCS octets) and were otherwise well formed. The maximum frame length could be 1522 octets if OneLevelVLAN is active or 1538 octets if TwoLevelVLAN is active.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeStatRxFCSCts 1.3.6.1.4.1.179.2.5.1.16.1.53
A count of received frames that are an integral number of octets in length and do not pass the FCS check. This does not include frames received with frame-too-long, or frame-too-short (frame fragment) error.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeStatRxOctets64Cts 1.3.6.1.4.1.179.2.5.1.16.1.55
The total number of frames (including bad frames) received that were 64 octets in length (excluding framing bits, but including FCS octets).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeStatRxOctets127Cts 1.3.6.1.4.1.179.2.5.1.16.1.56
The total number of frames (including bad frames) received that were between 65 and 127 octets in length inclusive (excluding framing bits, but including FCS octets).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeStatRxOctets255Cts 1.3.6.1.4.1.179.2.5.1.16.1.57
The total number of frames (including bad frames) received that were between 128 and 255 octets in length inclusive (excluding framing bits, but including FCS octets).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeStatRxOctets511Cts 1.3.6.1.4.1.179.2.5.1.16.1.58
The total number of frames (including bad frames) received that were between 256 and 511 octets in length inclusive (excluding framing bits, but including FCS octets).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeStatRxOctets1023Cts 1.3.6.1.4.1.179.2.5.1.16.1.59
The total number of frames (including bad frames) received that were between 512 and 1023 octets in length inclusive (excluding framing bits, but including FCS octets).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeStatRxOctetsMaxCts 1.3.6.1.4.1.179.2.5.1.16.1.60
The total number of frames (including bad frames) received that were between 1024 and 1518 octets in length inclusive (excluding framing bits, but including FCS octets). If the OneLevelVLAN is active, this statistic counts frames that are between 1024 and 1522 octets (excluding framing bits, but including FCS octets). If the TwoLevelVLAN is active, this statistic counts frames that are between 1024 and 1538 octets (excluding framing bits, but including FCS octets).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeStatRxLongFramesCts 1.3.6.1.4.1.179.2.5.1.16.1.61
The total number of frames received that are greater than the IEEE 802.3 maximum frame size. Typically, 1518 octets if neither the OneLevelVLAN nor TwoLevelVLAN is active, the long frames are defined as more than 1522 octets (excluding framing bits but including FCS octets). If the TowLevelVLAN is active, then long frames are defined as more than 1538 octets (excluding framing bits but including FCS octets).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeConfEntriesNumber 1.3.6.1.4.1.179.2.5.1.17
The number of entries in the skGeConfTable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

skGeConfTable 1.3.6.1.4.1.179.2.5.1.18
The table describes the physical port data. The number of table entries is stored in skGeConfEntriesNumber.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SkGeConfEntry

skGeConfEntry 1.3.6.1.4.1.179.2.5.1.18.1
The first entry (skGeConfIndex) of each adapter card (skGeConfGeIndex) is a virtual one and represents the active MAC instance with settled statistical data. This means that the number of port specific statistical data entries in this table is by one element higher than the physically provided port number (skGePortNumber).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SkGeConfEntry  

skGeConfGeIndex 1.3.6.1.4.1.179.2.5.1.18.1.1
Adapter index which corresponds with skGeIndex.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

skGeConfIndex 1.3.6.1.4.1.179.2.5.1.18.1.2
The port index. The value is equivalent to skGeStatPortIndex. The ports are enumerated from 1..n. The first entry is the virtual one.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

skGeConfPhysCurrentAddr 1.3.6.1.4.1.179.2.5.1.18.1.3
The physical address. The first entry of a adapter stores the physical address reported to the operating system. The other entries store the physical addresses of RLMT.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SkGeMACAddress  

skGeConfPhysFactoryAddr 1.3.6.1.4.1.179.2.5.1.18.1.4
The burned in physical address. The first entry of a adapter stores the physical address reported to the operating system. The other entries store the physical addresses of RLMT.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SkGeMACAddress  

skGeConfPMDType 1.3.6.1.4.1.179.2.5.1.18.1.5
Stores the physical media type of the port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), ge1000Base-LX(2), ge1000Base-SX(3), ge1000Base-CX(4), ge1000Base-T(5)  

skGeConfConnector 1.3.6.1.4.1.179.2.5.1.18.1.6
Stores the connector type of the port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), duplex-sc(2), d-sub(3), fc-s2(4), utp(5), volition(6)  

skGeConfLinkCap 1.3.6.1.4.1.179.2.5.1.18.1.7
Indicates which connection modes the port supports. The modes are stored as a sum of powers of 2. Mode Power 0 half-duplex 1 full-duplex 2 auto-half-duplex 3 auto-full-duplex
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..16  

skGeConfLinkMode 1.3.6.1.4.1.179.2.5.1.18.1.8
Defines in which mode the port should work. The modes half-duplex and full-duplex force the port to work in the corresponding mode. No autonegotiation is performed. The auto modes let the port perform autonegotiation with the capabilities half-duplex, full-duplex or both modes. The sense mode starts with autonegotiation and if failed falls back to full-duplex mode. After the link went down a new sense cycle is started.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER half-duplex(1), full-duplex(2), auto-half-duplex(3), auto-full-duplex(4), auto-both(5), sense(6)  

skGeConfLinkModeStatus 1.3.6.1.4.1.179.2.5.1.18.1.9
Stores the mode with which the port is currently working. The keyword auto indicates that the link mode was established by autonegotiation. Otherwise the port was forced into the current mode.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), half-duplex(2), full-duplex(3), auto-half-duplex(4), auto-full-duplex(5)  

skGeConfLinkStatus 1.3.6.1.4.1.179.2.5.1.18.1.10
Stores the link status of the unit. If a link becomes up or down a trap is generated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER link-physically-down(1), link-auto-failure(2), link-logically-down(3), link-logically-up(4)  

skGeConfFlowCtrlCap 1.3.6.1.4.1.179.2.5.1.18.1.11
Indicates which flow control types the port supports.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), local-send(2), symmetric(3), symmetric-or-remote-send(4)  

skGeConfFlowCtrlMode 1.3.6.1.4.1.179.2.5.1.18.1.12
Defines the flow-control type the port should announce during auto-negotiation. If auto-negotiation is disabled flow-control is disabled and settings to this variable have no effect.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), local-send(2), symmetric(3), symmetric-or-remote-send(4)  

skGeConfFlowCtrlStatus 1.3.6.1.4.1.179.2.5.1.18.1.13
Stores the flow-control type the port is currently using.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), remote-send(2), local-send(3), symmetric(4)  

skGeConfPhyOperationCap 1.3.6.1.4.1.179.2.5.1.18.1.14
Indicates which operation modes the phy supports. The modes are stored as a sum of powers of 2. Mode Power 0 master-slave auto-negotiation 1 master 2 slave
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..7  

skGeConfPhyOperationMode 1.3.6.1.4.1.179.2.5.1.18.1.15
Defines in which mode the phy should work. The modes master and slave force the port to work in the corresponding mode. No autonegotiation is performed. The auto mode lets the port perform autonegotiation with the capabilities.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER auto-negotiation(1), master(2), slave(3)  

skGeConfPhyOperationStatus 1.3.6.1.4.1.179.2.5.1.18.1.16
Stores the operation mode with which the port is currently working.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unset(1), master(2), slave(3), configuration-fault(4)  

skGeVpdTable 1.3.6.1.4.1.179.2.5.2.1
This table stores data for easy vpd access.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SkGeVpdEntry

skGeVpdEntry 1.3.6.1.4.1.179.2.5.2.1.1
Entry of skGeVpdTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SkGeVpdEntry  

skGeVpdIndex 1.3.6.1.4.1.179.2.5.2.1.1.1
Adapter index that corresponds to skGeIndex.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

skGeVpdFreeBytes 1.3.6.1.4.1.179.2.5.2.1.1.2
Stores the number of free bytes in the read-write area of the VPD RAM.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

skGeVpdEntryList 1.3.6.1.4.1.179.2.5.2.1.1.3
Stores a list of the VPD keywords. The elements of the list are separated by a space character (0x20).
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

skGeVpdValueTable 1.3.6.1.4.1.179.2.5.2.2
This table provides access to the Vital Product Data (VPD).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SkGeVpdValueEntry

skGeVpdValueEntry 1.3.6.1.4.1.179.2.5.2.2.1
VPD value table entry. On creation of a new entry: If the key is first set the vpd subsystem will create a new entry with an empty value field. If the value is first set the key must extracted from the oid and key a nd value are then set simultaneously.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SkGeVpdValueEntry  

skGeVpdValueIndex 1.3.6.1.4.1.179.2.5.2.2.1.1
Adapter index that corresponds to skGeIndex.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

skGeVpdKey 1.3.6.1.4.1.179.2.5.2.2.1.2
VPD keyword.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..4)  

skGeVpdValue 1.3.6.1.4.1.179.2.5.2.2.1.3
Value stored under VPD keyword.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

skGeVpdAccess 1.3.6.1.4.1.179.2.5.2.2.1.4
Defines whether the entry is only readable or also writable. Read-only entries cannot be changed or deleted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER read-write(1), read-only(2)  

skGeVpdValid 1.3.6.1.4.1.179.2.5.2.2.1.5
If the entry is writeable a set to 'invalid' will remove the entry from the VPD. A set to 'valid' will have no effect.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

skGeRlmtEntriesNumber 1.3.6.1.4.1.179.2.5.3.1
Stores the number of skGeRlmtTable entries. The number corresponds to skGeNumber.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

skGeRlmtTable 1.3.6.1.4.1.179.2.5.3.2
Table for RLMT (Redundant Link ManagemenT) specific data.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SkGeRlmtEntry

skGeRlmtEntry 1.3.6.1.4.1.179.2.5.3.2.1
Entry of skGeRlmtTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SkGeRlmtEntry  

skGeRlmtIndex 1.3.6.1.4.1.179.2.5.3.2.1.1
Stores the index of the adapter card that corresponds with this entry. It is identical to skGeIndex.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

skGeRlmtMode 1.3.6.1.4.1.179.2.5.3.2.1.2
Stores the working mode of RLMT as a power of 2. Mode Power link-check 0 Always active send-check 1 Sends hello packets spanning-tree 2 Monitors SP packets monitor 3 Monitors other GE-NICs
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..15  

skGeRlmtPortActive 1.3.6.1.4.1.179.2.5.3.2.1.3
Stores the index of the currently active port. The value 0 indicates that currently no port is active.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

skGeRlmtPortPreferred 1.3.6.1.4.1.179.2.5.3.2.1.4
If RLMT evaluates that all links are well working this value is used to decide which port should be used. The value ?0? indicates automatic mode and let RLMT do the decision.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

skGeRlmtChangeCts 1.3.6.1.4.1.179.2.5.3.2.1.5
Counts the number of times RLMT switched from one port to another which indicates an error.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeRlmtChangeTimeStamp 1.3.6.1.4.1.179.2.5.3.2.1.6
Stores the time in hundreds of seconds since the last reboot when the connection was switched to another port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

skGeRlmtChangeEstimate 1.3.6.1.4.1.179.2.5.3.2.1.7
Stores the number of port switches per hour.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

skGeRlmtChangeThreshold 1.3.6.1.4.1.179.2.5.3.2.1.8
Stores the threshold in number of port switches per hour. If the threshold is exceeded a trap is generated.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

skGeRlmtPortNumber 1.3.6.1.4.1.179.2.5.3.2.1.9
Stores the number of physically present ports.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

skGeRlmtStatEntriesNumber 1.3.6.1.4.1.179.2.5.3.3
Number of table elements in skGeRlmtStatTable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

skGeRlmtStatTable 1.3.6.1.4.1.179.2.5.3.4
Stores RLMT specific statistical data according to each port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SkGeRlmtStatEntry

skGeRlmtStatEntry 1.3.6.1.4.1.179.2.5.3.4.1
Entry of RLMT statistic table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SkGeRlmtStatEntry  

skGeRlmtStatGeIndex 1.3.6.1.4.1.179.2.5.3.4.1.1
Index of the adapter card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

skGeRlmtStatIndex 1.3.6.1.4.1.179.2.5.3.4.1.2
Index of the physical port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

skGeRlmtStatStatus 1.3.6.1.4.1.179.2.5.3.4.1.3
The working state of the port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER standby(1), active(2), error(3)  

skGeRlmtStatTxHelloCts 1.3.6.1.4.1.179.2.5.3.4.1.4
Number of hello packets sent in the send-check mode.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeRlmtStatRxHelloCts 1.3.6.1.4.1.179.2.5.3.4.1.5
Number of hello packets received in the send-check mode.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeRlmtStatTxSpHelloReqCts 1.3.6.1.4.1.179.2.5.3.4.1.6
Number of transmitted packets in spanning-tree mode to force a spanning-tree hello packet.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeRlmtStatRxSpHelloCts 1.3.6.1.4.1.179.2.5.3.4.1.7
Number of the received spanning-tree hello packets in the spanning-tree mode.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeRlmtMonitorEntriesNumber 1.3.6.1.4.1.179.2.5.3.5
Number of stations monitored by RLMT.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

skGeRlmtMonitorTable 1.3.6.1.4.1.179.2.5.3.6
Table of stations to be monitored by RLMT.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SkGeRlmtMonitorEntry

skGeRlmtMonitorEntry 1.3.6.1.4.1.179.2.5.3.6.1
Entry of skGeRlmtMonitorTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SkGeRlmtMonitorEntry  

skGeRlmtMonitorGeIndex 1.3.6.1.4.1.179.2.5.3.6.1.1
Index of the adapter card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

skGeRlmtMonitorIndex 1.3.6.1.4.1.179.2.5.3.6.1.2
Index of the address table entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

skGeRlmtMonitorAddr 1.3.6.1.4.1.179.2.5.3.6.1.3
Physical address of a monitored station.
Status: mandatory Access: read-write
OBJECT-TYPE    
  SkGeMACAddress  

skGeRlmtMonitorErrCts 1.3.6.1.4.1.179.2.5.3.6.1.4
Counts the number of times the redundant link of the monitored station got lost.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

skGeRlmtMonitorErrTimeStamp 1.3.6.1.4.1.179.2.5.3.6.1.5
Stores the timestamp of the last time the link got lost.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

skGeRlmtMonitorAdmin 1.3.6.1.4.1.179.2.5.3.6.1.6
Set to disable stops the monitoring of the remote station.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

skGeSensorWarningLower 500
This trap is generated when one of the adapter sensor values exceeds the lower warning threshold.
TRAP-TYPE    

skGeSensorWarningUpper 501
This trap is generated when one of the adapter sensor values exceeds the upper warning threshold.
TRAP-TYPE    

skGeSensorErrorLower 502
This trap is generated when one of the adapter sensor values exceeds the lower error threshold.
TRAP-TYPE    

skGeSensorErrorUpper 503
This trap is generated when one of the adapter sensor values exceeds the upper error threshold.
TRAP-TYPE    

skGeRlmtChangeThresholdCondition 520
This trap is generated when the port switches exceeded the threshold.
TRAP-TYPE    

skGeRlmtChangeCondition 521
This trap is generated when the connection is switched to another port. The with the trap passed variables correspond to the new active port.
TRAP-TYPE    

skGeRlmtPortDown 522
This trap is generated when RLMT detects that a port went logically down.
TRAP-TYPE    

skGeRlmtPortUp 523
This trap is generated when RLMT detects that a port went logically up.
TRAP-TYPE    

skGeRlmtSegmentation 524
This trap is generated when RLMT works in spanning-tree mode (skGeRlmtMode) and two root bridges are detected, which means a segmentation of net. One of the segments may be isolated from the rest of the net.
TRAP-TYPE