SIAE-SYNC-MIB
File:
SIAE-SYNC-MIB.mib (36060 bytes)
Imported modules
Imported symbols
Defined Types
TimingGenerator |
|
SEQUENCE |
|
|
|
|
timingGeneratorId |
Integer32 |
|
|
timingGeneratorT4vsT0 |
INTEGER |
|
|
timingGeneratorHoldOffTime |
INTEGER |
|
|
timingGeneratorWtrTime |
INTEGER |
|
|
timingGeneratorSinkLosSet |
INTEGER |
|
|
timingGeneratorSinkLosReset |
INTEGER |
|
|
timingGeneratorT0SquelchAlarm |
AlarmStatus |
|
|
timingGeneratorT4SquelchAlarm |
AlarmStatus |
|
|
timingGeneratorFreeRunningStatus |
AlarmStatus |
|
|
timingGeneratorHoldoverStatus |
AlarmStatus |
|
|
timingGeneratorActiveStatus |
INTEGER |
|
|
timingGeneratorT0CurrentQuality |
INTEGER |
|
|
timingGeneratorT4CurrentQuality |
INTEGER |
|
|
timingGeneratorT4MinimumQuality |
INTEGER |
|
|
timingGeneratorT0PreferredSource |
OBJECT IDENTIFIER |
|
|
timingGeneratorT4PreferredSource |
OBJECT IDENTIFIER |
|
|
timingGeneratorRowStatus |
RowStatus |
|
TimingGeneratorMaintRecord |
|
SEQUENCE |
|
|
|
|
timingGeneratorT4Squelch |
INTEGER |
|
|
timingGeneratorStatusControl |
INTEGER |
|
|
timingGeneratorT0ForcedSource |
OBJECT IDENTIFIER |
|
|
timingGeneratorT4ForcedSource |
OBJECT IDENTIFIER |
|
|
timingGeneratorWtrClearSource |
OBJECT IDENTIFIER |
|
TimingSink |
|
SEQUENCE |
|
|
|
|
timingSinkGenId |
Integer32 |
|
|
timingSinkId |
Integer32 |
|
|
timingSinkType |
INTEGER |
|
|
timingSinkIfIndex |
InterfaceIndexOrZero |
|
|
timingSinkSelector |
Integer32 |
|
|
timingSinkPriority |
INTEGER |
|
|
timingSinkLabel |
DisplayString |
|
|
timingSinkLosAlarm |
AlarmStatus |
|
|
timingSinkDriftAlarm |
AlarmStatus |
|
|
timingSinkActiveStatus |
INTEGER |
|
|
timingSinkCurrentQuality |
INTEGER |
|
|
timingSinkOverwriteTxQuality |
INTEGER |
|
|
timingSinkOverwriteRxQuality |
INTEGER |
|
|
timingSinkSentQuality |
INTEGER |
|
|
timingSinkE1Sabit |
INTEGER |
|
|
timingSinkEthPortRole |
INTEGER |
|
|
timingSinkRowStatus |
RowStatus |
|
Defined Values
sync |
1.3.6.1.4.1.3373.1103.28 |
Timing Source Management.
|
MODULE-IDENTITY |
|
|
|
syncMibVersion |
1.3.6.1.4.1.3373.1103.28.1 |
Numerical version of this module.
The string version of this MIB have the following format:
XX.YY.ZZ
so, for example, the value 1 should be interpreted as 00.00.01
and the value 10001 should be interpreted as 01.00.01. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
timingGeneratorId |
1.3.6.1.4.1.3373.1103.28.2.1.1 |
This object is used as Index of the Timing Generator Table. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
timingGeneratorT4vsT0 |
1.3.6.1.4.1.3373.1103.28.2.1.2 |
This object is used to set or reset the condition T4 equal T0. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
INTEGER |
t4NotEqualT0(1), t4EqualT0(2) |
|
timingGeneratorHoldOffTime |
1.3.6.1.4.1.3373.1103.28.2.1.3 |
HoldOff time in milliseconds (300..1800). |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
INTEGER |
300..1800 |
|
timingGeneratorWtrTime |
1.3.6.1.4.1.3373.1103.28.2.1.4 |
Wait Time to Restore in minutes (0..12). |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..12 |
|
timingGeneratorSinkLosSet |
1.3.6.1.4.1.3373.1103.28.2.1.5 |
Wait time (seconds) before to set Los of reference signal. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..60 |
|
timingGeneratorSinkLosReset |
1.3.6.1.4.1.3373.1103.28.2.1.6 |
Wait time (seconds) before to reset Los of reference signal. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..60 |
|
timingGeneratorActiveStatus |
1.3.6.1.4.1.3373.1103.28.2.1.11 |
Active status (Probable cause = xxx) with associated severity. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
cleared(1), activeReportableStatus(2) |
|
timingGeneratorT0CurrentQuality |
1.3.6.1.4.1.3373.1103.28.2.1.12 |
Current quality on T0. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
qUNKN(0), qPRC(2), qSSUT(4), qSSUL(8), qSEC(11), qDNU(15) |
|
timingGeneratorT4CurrentQuality |
1.3.6.1.4.1.3373.1103.28.2.1.13 |
Current quality on T4. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
qUNKN(0), qPRC(2), qSSUT(4), qSSUL(8), qSEC(11), qDNU(15) |
|
timingGeneratorT4MinimumQuality |
1.3.6.1.4.1.3373.1103.28.2.1.14 |
If the Quality Level of the signal used to derive T4 falls below
timingGeneratorT4MinimumQuality then the output will be squelched.
The value ql-DNU inhibits T4 squelch due to this minimum Quality
Level. This feature is enabled by timingGeneratorT4Squelch when
timingGeneratorQualityEnable is on(2). |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
INTEGER |
qPRC(2), qSSUT(4), qSSUL(8), qSEC(11) |
|
timingGeneratorT0PreferredSource |
1.3.6.1.4.1.3373.1103.28.2.1.15 |
Object identifier of the leaf timingSinkGenId of the timingSink
instance selected as preferential clock source of T0.
If no preferential timing sink is selected,
the value should be set to the OBJECT IDENTIFIER { 0 0 }.
|
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
OBJECT IDENTIFIER |
|
|
timingGeneratorT4PreferredSource |
1.3.6.1.4.1.3373.1103.28.2.1.16 |
Object identifier of the leaf timingSinkGenId of the timingSink
instance selected as preferential clock source of T4.
If no preferential timing sink is selected,
the value should be set to the OBJECT IDENTIFIER { 0 0 }.
|
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
OBJECT IDENTIFIER |
|
|
timingGeneratorMaintTable |
1.3.6.1.4.1.3373.1103.28.3 |
Table with TimingGenerator records. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
TimingGeneratorMaintRecord |
|
timingGeneratorMaintRecord |
1.3.6.1.4.1.3373.1103.28.3.1 |
TimingGenerator record. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
TimingGeneratorMaintRecord |
|
|
timingGeneratorT4Squelch |
1.3.6.1.4.1.3373.1103.28.3.1.1 |
This object is used to enable/disable T4 squelch. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
disable(1), enable(2) |
|
timingGeneratorStatusControl |
1.3.6.1.4.1.3373.1103.28.3.1.2 |
Clock generator operating mode control.
This item is linked to a manual operation (ManOpRecord) instance. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
freerunning(1), holdover(2), locked(3) |
|
timingGeneratorT0ForcedSource |
1.3.6.1.4.1.3373.1103.28.3.1.3 |
Object identifier of the leaf timingSinkGenId of the timingSink
instance selected as forced clock source of T0.
If no forced timing sink is selected,
the value should be set to the OBJECT IDENTIFIER { 0 0 }.
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
OBJECT IDENTIFIER |
|
|
timingGeneratorT4ForcedSource |
1.3.6.1.4.1.3373.1103.28.3.1.4 |
Object identifier of the leaf timingSinkGenId of the timingSink
instance selected as forced clock source of T4.
If no forced timing sink is selected,
the value should be set to the OBJECT IDENTIFIER { 0 0 }.
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
OBJECT IDENTIFIER |
|
|
timingGeneratorWtrClearSource |
1.3.6.1.4.1.3373.1103.28.3.1.5 |
Object identifier of the leaf timingSinkGenId of the timingSink
instance selected to clear WTR time. On read, this object return
alvays an OBJECT IDENTIFIER {0 0}.
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
OBJECT IDENTIFIER |
|
|
timingSinkTable |
1.3.6.1.4.1.3373.1103.28.4 |
Table with TimingSink records. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
TimingSink |
|
timingSinkGenId |
1.3.6.1.4.1.3373.1103.28.4.1.1 |
This object is used as Index of the timingGeneratorTable and
defines in union with timingSinkType and timingSinkId the
reference signal.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
timingSinkId |
1.3.6.1.4.1.3373.1103.28.4.1.2 |
This object is used as Index of the timingSinkTable and
defines in union with timingSinkType and timingSinkGenId the
reference signal.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
timingSinkType |
1.3.6.1.4.1.3373.1103.28.4.1.3 |
This object is used as Index of the timingSinkTable and defines
if the reference signal is used to generate T0 or T4 system clock.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
t0(1), t4(2) |
|
timingSinkSelector |
1.3.6.1.4.1.3373.1103.28.4.1.5 |
This object is used to select one of the possible clock source
connected to this timingSink. Valid values are listed in
timingSinkSelectorTable: only values of timingSinkSelectorId
related to this instance of timinkSinkRecord are accepted.
Only the values corresponding to the index timingSinkSelectorId of
timinkSinkSelectorTable related to this instance of
timinkSinkRecord will be accepted.
|
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
timingSinkPriority |
1.3.6.1.4.1.3373.1103.28.4.1.6 |
This object is used to set the priority of the reference signal (p1 is
the highest priority). |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
INTEGER |
p1(1), p2(2), p3(3), p4(4), p5(5), p6(6), p7(7), p8(8), p9(9), p10(10), p11(11), p12(12), p13(13), p14(14), p15(15), disable(16) |
|
timingSinkLabel |
1.3.6.1.4.1.3373.1103.28.4.1.7 |
ASCII string used to describe the reference signal when a trap is sent. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..31) |
|
timingSinkLosAlarm |
1.3.6.1.4.1.3373.1103.28.4.1.8 |
Loss of reference signal (Probable cause = xxx) alarm
with associated severity. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
AlarmStatus |
|
|
timingSinkDriftAlarm |
1.3.6.1.4.1.3373.1103.28.4.1.9 |
Drift of reference signal (Probable cause = xxx) alarm
with associated severity. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
AlarmStatus |
|
|
timingSinkActiveStatus |
1.3.6.1.4.1.3373.1103.28.4.1.10 |
Active status (Probable cause = xxx) status for the reference signal. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
cleared(1), activeReportableStatus(2) |
|
timingSinkCurrentQuality |
1.3.6.1.4.1.3373.1103.28.4.1.11 |
Current quality on sink instance. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
qUNKN(0), qPRC(2), qSSUT(4), qSSUL(8), qSEC(11), qDNU(15) |
|
timingSinkOverwriteTxQuality |
1.3.6.1.4.1.3373.1103.28.4.1.12 |
Forcing of Tx quality parameter. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
INTEGER |
noOverwrite(0), qPRC(2), qSSUT(4), qSSUL(8), qSEC(11), qDNU(15) |
|
timingSinkOverwriteRxQuality |
1.3.6.1.4.1.3373.1103.28.4.1.13 |
Forcing of Rx quality parameter. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
INTEGER |
noOverwrite(0), qPRC(2), qSSUT(4), qSSUL(8), qSEC(11), qDNU(15) |
|
timingSinkSentQuality |
1.3.6.1.4.1.3373.1103.28.4.1.14 |
Quality level written in the S1 byte of the outgoing STM-n. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
qUNKN(0), qPRC(2), qSSUT(4), qSSUL(8), qSEC(11), qDNU(15) |
|
timingSinkE1Sabit |
1.3.6.1.4.1.3373.1103.28.4.1.15 |
Specifies the San synchronization status bit used
to indicate the clock quality level.
Meaningful when the Sink source is an E1 |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
INTEGER |
4..8 |
|
timingSinkEthPortRole |
1.3.6.1.4.1.3373.1103.28.4.1.16 |
This item configures how to handle the role of a 1000BASE-T port
when it is used as a source of timing: choosing 'static', the
role is set according ethLanPhyTable settings, choosing 'dynamic',
the role is set consistently with the timing direction over the
1000baseT link chosen by SSM protocol. |
Status: deprecated |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
INTEGER |
static(1), dynamic(2) |
|
timingSinkRowStatus |
1.3.6.1.4.1.3373.1103.28.4.1.17 |
Status of this row of timingSinkTable
|
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
RowStatus |
|
|
timingGeneratorManualSwitch |
1.3.6.1.4.1.3373.1103.28.5 |
timingGeneratorId of the forced timingGenerator instance.
If no preferred timing generator is selected, the value
should be set to 0.
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
timingGeneratorForcedSwitch |
1.3.6.1.4.1.3373.1103.28.6 |
timingGeneratorId of the forced timingGenerator instance.
If no forced timing generator is selected, the value
should be set to 0.
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
timingGeneratorActiveStatusSeverityCode |
1.3.6.1.4.1.3373.1103.28.11 |
Defines the severity associated to the timingGeneratorActiveStatus
and enables/disables the trap generation on status change event. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
disable(1), statusTrapEnable(2) |
|
timingGeneratorQualityEnable |
1.3.6.1.4.1.3373.1103.28.12 |
Quality policy enable |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
off(1), on(2) |
|
timingSinkLosAlarmSeverityCode |
1.3.6.1.4.1.3373.1103.28.13 |
Defines the severity associated to the TimingSinkLosAlarm
and enables/disables the trap generation on status change event. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
AlarmSeverityCode |
|
|
timingSinkDriftAlarmSeverityCode |
1.3.6.1.4.1.3373.1103.28.14 |
Defines the severity associated to the TimingSinkDriftAlarm
and enables/disables the trap generation on status change event. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
AlarmSeverityCode |
|
|
timingSinkActiveStatusSeverityCode |
1.3.6.1.4.1.3373.1103.28.15 |
Defines the severity associated to the timingSinkActiveStatus
and enables/disables the trap generation on status change event. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
disable(1), statusTrapEnable(2) |
|
timingSinkSelectorRecord |
1.3.6.1.4.1.3373.1103.28.16.1 |
TimingSinkSelector entry.
Several instances of this entry can be create for each instance of
timingSinkTable. Each entry represents a possible source selected
by a multiplexer outside the SETS for a specific timingSink.
Only the values corresponding to the index timingSinkSelectorId can
be set to timingSinkSelector.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
TimingSinkSelector |
|
|
timingSinkSelectorId |
1.3.6.1.4.1.3373.1103.28.16.1.1 |
This object is used as Index of the timingSinkSelectorTable and
defines in union with timingSinkGenId, timingSinkType and
timingSinkId the selected source by a multiplexer outside the
SETS.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
timingSinkSelectorLabel |
1.3.6.1.4.1.3373.1103.28.16.1.2 |
ASCII string used to describe the selectable timing source.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..31) |
|
esmcTable |
1.3.6.1.4.1.3373.1103.28.17 |
Table with TimingSinkSelector records. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
EsmcRecord |
|
esmcRecord |
1.3.6.1.4.1.3373.1103.28.17.1 |
esmcTable entry.
Every entries describes an ESMC channel of a TE interface.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
EsmcRecord |
|
|
esmcSsmEnable |
1.3.6.1.4.1.3373.1103.28.17.1.1 |
This object enables SSM messaging on this ifIndex.
|
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
INTEGER |
disable(1), enable(2) |
|
esmcQlRx |
1.3.6.1.4.1.3373.1103.28.17.1.2 |
This object show quality received on ESMC-PDU this interface.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
qUNKN(0), qPRC(2), qSSUT(4), qSSUL(8), qSEC(11), qDNU(15) |
|
esmcQlTx |
1.3.6.1.4.1.3373.1103.28.17.1.3 |
This object show quality transmitted in ESMC-PDU on this interface.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
qUNKN(0), qPRC(2), qSSUT(4), qSSUL(8), qSEC(11), qDNU(15) |
|
esmcPktsRx |
1.3.6.1.4.1.3373.1103.28.17.1.4 |
This object contains the total number of received ESMC-PDU packets
on this interface.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
esmcPktsTx |
1.3.6.1.4.1.3373.1103.28.17.1.5 |
This object contains the total number of transmitted ESMC-PDU
packets on this interface.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
esmcPktsRxDropped |
1.3.6.1.4.1.3373.1103.28.17.1.6 |
This object contains the total number of dropped ESMC-PDU packets
on this interface.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
esmcPktsRxErrored |
1.3.6.1.4.1.3373.1103.28.17.1.7 |
This object contains the total number of dropped ESMC-PDU packets
whose processing(decoding) resulted into error.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
esmc1000BaseTRole |
1.3.6.1.4.1.3373.1103.28.17.1.8 |
This object allows to input the clock generator role of a 1000BaseT
interface. This objects is applicable when the quality management
is disabled (timingGeneratorQualityEnable set to off(1)) and to
all interfaces not connected to any timingSink when the quality
management is enabled.
|
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
INTEGER |
slave(1), master(2), auto(3) |
|
esmcRowStatus |
1.3.6.1.4.1.3373.1103.28.17.1.9 |
Status of this row of esmcTable.
|
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
RowStatus |
|
|