SERVERVIEW-STATUS-MIB

File: SERVERVIEW-STATUS-MIB.mib (18433 bytes)

Imported modules

RFC-1212 RFC1213-MIB RFC1155-SMI

Imported symbols

OBJECT-TYPE mib-2 DisplayString
Counter Gauge IpAddress
enterprises

Defined Types

SieStSubsystems  
SEQUENCE    
  sieStSubsystemNumber INTEGER
  sieStSubsystemName DisplayString
  sieStSubsystemStatusValue INTEGER
  sieStSubsystemLastErrorMessage DisplayString
  sieStSubsystemComponents DisplayString
  sieStSubsystemDisplayName DisplayString

SieStComponents  
SEQUENCE    
  sieStComponentNumber INTEGER
  sieStComponentName DisplayString
  sieStComponentStatusValue INTEGER
  sieStComponentLastErrorMessage DisplayString
  sieStComponentDisplayName DisplayString
  sieStComponentConfirmFailure INTEGER

Defined Values

sni 1.3.6.1.4.1.231
OBJECT IDENTIFIER    

sniProductMibs 1.3.6.1.4.1.231.2
OBJECT IDENTIFIER    

sniExtensions 1.3.6.1.4.1.231.2.10
OBJECT IDENTIFIER    

sniServerMgmt 1.3.6.1.4.1.231.2.10.2
OBJECT IDENTIFIER    

sniInventory 1.3.6.1.4.1.231.2.10.2.1
OBJECT IDENTIFIER    

sniCommon 1.3.6.1.4.1.231.2.10.2.2
OBJECT IDENTIFIER    

sniBios 1.3.6.1.4.1.231.2.10.2.2.1
OBJECT IDENTIFIER    

sniEisa 1.3.6.1.4.1.231.2.10.2.2.2
OBJECT IDENTIFIER    

sniHd 1.3.6.1.4.1.231.2.10.2.2.3
OBJECT IDENTIFIER    

sniBus 1.3.6.1.4.1.231.2.10.2.2.4
OBJECT IDENTIFIER    

sniServerControl 1.3.6.1.4.1.231.2.10.2.2.5
OBJECT IDENTIFIER    

sniPcSpecific 1.3.6.1.4.1.231.2.10.2.3
OBJECT IDENTIFIER    

sniScb 1.3.6.1.4.1.231.2.10.2.4
OBJECT IDENTIFIER    

sniOsSpecific 1.3.6.1.4.1.231.2.10.2.5
OBJECT IDENTIFIER    

sniNetware 1.3.6.1.4.1.231.2.10.2.5.1
OBJECT IDENTIFIER    

sniWinNt 1.3.6.1.4.1.231.2.10.2.5.2
OBJECT IDENTIFIER    

sniOs2 1.3.6.1.4.1.231.2.10.2.5.3
OBJECT IDENTIFIER    

sniUnix 1.3.6.1.4.1.231.2.10.2.5.4
OBJECT IDENTIFIER    

sniOemComponents 1.3.6.1.4.1.231.2.10.2.6
OBJECT IDENTIFIER    

sniOemDpt 1.3.6.1.4.1.231.2.10.2.6.1
OBJECT IDENTIFIER    

sniOemMylex 1.3.6.1.4.1.231.2.10.2.6.2
OBJECT IDENTIFIER    

sniMlxDiskArray 1.3.6.1.4.1.231.2.10.2.6.2.1
OBJECT IDENTIFIER    

sniSecurity 1.3.6.1.4.1.231.2.10.2.7
OBJECT IDENTIFIER    

sniSmSecurity 1.3.6.1.4.1.231.2.10.2.7.1
OBJECT IDENTIFIER    

sniServerView 1.3.6.1.4.1.231.2.10.2.8
OBJECT IDENTIFIER    

sniTrapMib 1.3.6.1.4.1.231.2.10.5
OBJECT IDENTIFIER    

sieStatusAgent 1.3.6.1.4.1.231.2.10.2.11
OBJECT IDENTIFIER    

sieStAgentInfo 1.3.6.1.4.1.231.2.10.2.11.1
OBJECT IDENTIFIER    

sieStSystemStatus 1.3.6.1.4.1.231.2.10.2.11.2
OBJECT IDENTIFIER    

sieStSubsystemStatus 1.3.6.1.4.1.231.2.10.2.11.3
OBJECT IDENTIFIER    

sieStComponentStatus 1.3.6.1.4.1.231.2.10.2.11.4
OBJECT IDENTIFIER    

sieStAgentParameters 1.3.6.1.4.1.231.2.10.2.11.5
OBJECT IDENTIFIER    

sieStTrapParameters 1.3.6.1.4.1.231.2.10.2.11.10
OBJECT IDENTIFIER    

sieStAgentId 1.3.6.1.4.1.231.2.10.2.11.1.1
Agent identification string
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sieStAgentCompany 1.3.6.1.4.1.231.2.10.2.11.1.2
Agent company name
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sieStAgentVersionString 1.3.6.1.4.1.231.2.10.2.11.1.3
Agent version string . (i.e. 1.05)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sieStAgentBuild 1.3.6.1.4.1.231.2.10.2.11.1.4
Build time and date of agent program implementation
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sieStSystemStatusValue 1.3.6.1.4.1.231.2.10.2.11.2.1
Overall status of this system: ok(1): all subsystems and components working properly, no failure degraded(2): redundant components failed or signal a warning error(3): severe problem, system may no longer work properly failed(4): this value is obsolete - will no longer appear unknown(5): none of the subsystems had a valid status (e.g. during initialization)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), degraded(2), error(3), failed(4), unknown(5)  

sieStSystemLastErrorMessage 1.3.6.1.4.1.231.2.10.2.11.2.2
Error message text of the component that has failed last. Empty string, if no error has happened since reboot. This object is not supported by all components and can therefore be empty although an error happened.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sieStSubsystemList 1.3.6.1.4.1.231.2.10.2.11.2.3
List if subsystems included in this system, separated by blank spaces. E.g. 'Environment PowerSupply MassStorage'
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sieStSystemIdentify 1.3.6.1.4.1.231.2.10.2.11.2.4
Sets the signal IDENTIFY for the system: off(1): clear the identify signal / signal is off on(2): set the IDENTIFY signal not-available(3): identify signal ist not available (this value cannot be set) blinking(4): IDENTIFY LED blinking, used for different purposes Setting IDENTIFY by the ServerView application normally sets a LED to have the possibility to identify a system selected by ServerView.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2), not-available(3), blinking(4)  

sieStSubsystemTable 1.3.6.1.4.1.231.2.10.2.11.3.1
Table containing the monitored subsystems
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SieStSubsystems

sieStSubsystems 1.3.6.1.4.1.231.2.10.2.11.3.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SieStSubsystems  

sieStSubsystemNumber 1.3.6.1.4.1.231.2.10.2.11.3.1.1.1
Subsystem number (index, 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sieStSubsystemName 1.3.6.1.4.1.231.2.10.2.11.3.1.1.2
Subsystem name. This name identifies the subsystem and will never be changed if once defined. This name is a string like 'Environment', 'PowerSupply', 'MassStorage' etc.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sieStSubsystemStatusValue 1.3.6.1.4.1.231.2.10.2.11.3.1.1.3
Subsystem status value: ok(1): all components in this subsystem working properly degraded(2): redundant components failed or signal a warning error(3): severe problem, system may no longer work properly failed(4): this value is obsolete - will no longer appear unknown(5): none of the components had a valid status (initialization, no components)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), degraded(2), error(3), failed(4), unknown(5)  

sieStSubsystemLastErrorMessage 1.3.6.1.4.1.231.2.10.2.11.3.1.1.4
Error message text of the component that has failed last. Empty string, if no error has happened since reboot. This object is not supported by all components and can therefore be empty although an error happened.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sieStSubsystemComponents 1.3.6.1.4.1.231.2.10.2.11.3.1.1.5
List if components (short names) included in this subsystem, separated by blank spaces; e.g. 'SvPowerSupply OemUpsAPC'
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sieStSubsystemDisplayName 1.3.6.1.4.1.231.2.10.2.11.3.1.1.6
Subsystem display name string.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sieStNumberSubsystems 1.3.6.1.4.1.231.2.10.2.11.3.2
Number of available subsystems; this is the number of entries in the subsystem table
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sieStComponentTable 1.3.6.1.4.1.231.2.10.2.11.4.1
Table containing the monitored components
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SieStComponents

sieStComponents 1.3.6.1.4.1.231.2.10.2.11.4.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SieStComponents  

sieStComponentNumber 1.3.6.1.4.1.231.2.10.2.11.4.1.1.1
Component number (index, 1..n)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sieStComponentName 1.3.6.1.4.1.231.2.10.2.11.4.1.1.2
Component name/tag. This name identifies the component and will never be changed if once defined. This name is a string like 'SvEnvironment', 'SvVoltages', 'OemUpsAPC' etc.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sieStComponentStatusValue 1.3.6.1.4.1.231.2.10.2.11.4.1.1.3
Component status value: ok(1): component is working properly degraded(2): redundant component has failed or signals a warning error(3): severe problem, system may no longer work properly failed(4): this value is obsolete - will no longer appear unknown(5): component had no valid status (initialization, no instances) notPresent(6): component is not present (e.g. empty socket) notManageable(7): component is not manageable
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), degraded(2), error(3), failed(4), unknown(5), notPresent(6), notManageable(7)  

sieStComponentLastErrorMessage 1.3.6.1.4.1.231.2.10.2.11.4.1.1.4
Error message text of the current component. Empty string, if no error has happened since reboot. This object is not supported by all components and can therefore be empty although an error happened.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sieStComponentDisplayName 1.3.6.1.4.1.231.2.10.2.11.4.1.1.5
Component display name string.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sieStComponentConfirmFailure 1.3.6.1.4.1.231.2.10.2.11.4.1.1.6
Confirm a failure status of a component that does not automatically reset its status (e.g. BIOS selftest error). The error condition is removed after the failure has been confirmed. GET values: 0 - no failure to confirm; SET not possible >0 - component failure; SET a zero value to confirm SET values: 0 - confirm failure and remove error condition (setting other values than 0 is not possible)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sieStNumberComponents 1.3.6.1.4.1.231.2.10.2.11.4.2
Number of available components; this is the number of entries in the component table
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sieStAgentType 1.3.6.1.4.1.231.2.10.2.11.5.1
Type of agent (i.e. 'Desktop' or 'Server'). This field can be used to launch the correct management front end application (DeskView or ServerView) in enterprise management systems.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

sieStTrapParamServerName 1.3.6.1.4.1.231.2.10.2.11.10.1
Name of server the trap occured at
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DisplayString  

sieStTrapParamTimestamp 1.3.6.1.4.1.231.2.10.2.11.10.2
Time the trap occured (in seconds since 01/01/1970 00:00h)
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER  

sieStTrapStatusChanged 1100
System status has changed.
TRAP-TYPE