SERVERVIEW-STATUS-MIB
File:
SERVERVIEW-STATUS-MIB.mib (18433 bytes)
Imported modules
Imported symbols
Defined Types
Defined Values
sni |
1.3.6.1.4.1.231 |
OBJECT IDENTIFIER |
|
|
|
sniCommon |
1.3.6.1.4.1.231.2.10.2.2 |
OBJECT IDENTIFIER |
|
|
|
sniBios |
1.3.6.1.4.1.231.2.10.2.2.1 |
OBJECT IDENTIFIER |
|
|
|
sniEisa |
1.3.6.1.4.1.231.2.10.2.2.2 |
OBJECT IDENTIFIER |
|
|
|
sniHd |
1.3.6.1.4.1.231.2.10.2.2.3 |
OBJECT IDENTIFIER |
|
|
|
sniBus |
1.3.6.1.4.1.231.2.10.2.2.4 |
OBJECT IDENTIFIER |
|
|
|
sniScb |
1.3.6.1.4.1.231.2.10.2.4 |
OBJECT IDENTIFIER |
|
|
|
sniNetware |
1.3.6.1.4.1.231.2.10.2.5.1 |
OBJECT IDENTIFIER |
|
|
|
sniWinNt |
1.3.6.1.4.1.231.2.10.2.5.2 |
OBJECT IDENTIFIER |
|
|
|
sniOs2 |
1.3.6.1.4.1.231.2.10.2.5.3 |
OBJECT IDENTIFIER |
|
|
|
sniUnix |
1.3.6.1.4.1.231.2.10.2.5.4 |
OBJECT IDENTIFIER |
|
|
|
sniOemDpt |
1.3.6.1.4.1.231.2.10.2.6.1 |
OBJECT IDENTIFIER |
|
|
|
sniOemMylex |
1.3.6.1.4.1.231.2.10.2.6.2 |
OBJECT IDENTIFIER |
|
|
|
sniTrapMib |
1.3.6.1.4.1.231.2.10.5 |
OBJECT IDENTIFIER |
|
|
|
sieStAgentId |
1.3.6.1.4.1.231.2.10.2.11.1.1 |
Agent identification string |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
sieStAgentBuild |
1.3.6.1.4.1.231.2.10.2.11.1.4 |
Build time and date of agent program implementation |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
sieStSystemStatusValue |
1.3.6.1.4.1.231.2.10.2.11.2.1 |
Overall status of this system:
ok(1): all subsystems and components working properly, no failure
degraded(2): redundant components failed or signal a warning
error(3): severe problem, system may no longer work properly
failed(4): this value is obsolete - will no longer appear
unknown(5): none of the subsystems had a valid status (e.g. during initialization) |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
ok(1), degraded(2), error(3), failed(4), unknown(5) |
|
sieStSystemLastErrorMessage |
1.3.6.1.4.1.231.2.10.2.11.2.2 |
Error message text of the component that has failed last. Empty string,
if no error has happened since reboot. This object is not supported by
all components and can therefore be empty although an error happened. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
sieStSubsystemList |
1.3.6.1.4.1.231.2.10.2.11.2.3 |
List if subsystems included in this system, separated
by blank spaces. E.g. 'Environment PowerSupply MassStorage' |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
sieStSystemIdentify |
1.3.6.1.4.1.231.2.10.2.11.2.4 |
Sets the signal IDENTIFY for the system:
off(1): clear the identify signal / signal is off
on(2): set the IDENTIFY signal
not-available(3): identify signal ist not available (this value cannot be set)
blinking(4): IDENTIFY LED blinking, used for different purposes
Setting IDENTIFY by the ServerView application normally sets a LED
to have the possibility to identify a system selected by ServerView. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
off(1), on(2), not-available(3), blinking(4) |
|
sieStSubsystemTable |
1.3.6.1.4.1.231.2.10.2.11.3.1 |
Table containing the monitored subsystems |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
SieStSubsystems |
|
sieStSubsystemNumber |
1.3.6.1.4.1.231.2.10.2.11.3.1.1.1 |
Subsystem number (index, 1..n) |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
sieStSubsystemName |
1.3.6.1.4.1.231.2.10.2.11.3.1.1.2 |
Subsystem name. This name identifies the subsystem and will never
be changed if once defined. This name is a string like 'Environment',
'PowerSupply', 'MassStorage' etc. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
sieStSubsystemStatusValue |
1.3.6.1.4.1.231.2.10.2.11.3.1.1.3 |
Subsystem status value:
ok(1): all components in this subsystem working properly
degraded(2): redundant components failed or signal a warning
error(3): severe problem, system may no longer work properly
failed(4): this value is obsolete - will no longer appear
unknown(5): none of the components had a valid status (initialization, no components) |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
ok(1), degraded(2), error(3), failed(4), unknown(5) |
|
sieStSubsystemLastErrorMessage |
1.3.6.1.4.1.231.2.10.2.11.3.1.1.4 |
Error message text of the component that has failed last. Empty string,
if no error has happened since reboot. This object is not supported by
all components and can therefore be empty although an error happened. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
sieStSubsystemComponents |
1.3.6.1.4.1.231.2.10.2.11.3.1.1.5 |
List if components (short names) included in this subsystem, separated
by blank spaces; e.g. 'SvPowerSupply OemUpsAPC' |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
sieStNumberSubsystems |
1.3.6.1.4.1.231.2.10.2.11.3.2 |
Number of available subsystems; this is the number of entries in the subsystem table |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
sieStComponentTable |
1.3.6.1.4.1.231.2.10.2.11.4.1 |
Table containing the monitored components |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
SieStComponents |
|
sieStComponentNumber |
1.3.6.1.4.1.231.2.10.2.11.4.1.1.1 |
Component number (index, 1..n) |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
sieStComponentName |
1.3.6.1.4.1.231.2.10.2.11.4.1.1.2 |
Component name/tag. This name identifies the component and will never
be changed if once defined. This name is a string like 'SvEnvironment',
'SvVoltages', 'OemUpsAPC' etc. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
sieStComponentStatusValue |
1.3.6.1.4.1.231.2.10.2.11.4.1.1.3 |
Component status value:
ok(1): component is working properly
degraded(2): redundant component has failed or signals a warning
error(3): severe problem, system may no longer work properly
failed(4): this value is obsolete - will no longer appear
unknown(5): component had no valid status (initialization, no instances)
notPresent(6): component is not present (e.g. empty socket)
notManageable(7): component is not manageable |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
ok(1), degraded(2), error(3), failed(4), unknown(5), notPresent(6), notManageable(7) |
|
sieStComponentLastErrorMessage |
1.3.6.1.4.1.231.2.10.2.11.4.1.1.4 |
Error message text of the current component. Empty string,
if no error has happened since reboot. This object is not supported by
all components and can therefore be empty although an error happened. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
sieStComponentConfirmFailure |
1.3.6.1.4.1.231.2.10.2.11.4.1.1.6 |
Confirm a failure status of a component that does not automatically
reset its status (e.g. BIOS selftest error). The error condition is
removed after the failure has been confirmed.
GET values: 0 - no failure to confirm; SET not possible
>0 - component failure; SET a zero value to confirm
SET values: 0 - confirm failure and remove error condition
(setting other values than 0 is not possible) |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
sieStNumberComponents |
1.3.6.1.4.1.231.2.10.2.11.4.2 |
Number of available components; this is the number of entries in the component table |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
sieStAgentType |
1.3.6.1.4.1.231.2.10.2.11.5.1 |
Type of agent (i.e. 'Desktop' or 'Server').
This field can be used to launch the correct management front end
application (DeskView or ServerView) in enterprise management systems. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
sieStTrapParamTimestamp |
1.3.6.1.4.1.231.2.10.2.11.10.2 |
Time the trap occured (in seconds since 01/01/1970 00:00h) |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|