SDEVICE-MIB

File: SDEVICE-MIB.mib (34501 bytes)

Imported modules

SNMPv2-CONF SNMPv2-SMI SNMPv2-TC

Imported symbols

MODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP
Integer32 IpAddress MODULE-IDENTITY
NOTIFICATION-TYPE OBJECT-IDENTITY OBJECT-TYPE
enterprises DisplayString MacAddress
TEXTUAL-CONVENTION

Defined Types

ConfigurationEntry  
SEQUENCE    
  channelIndex2 Integer32
  noPhases Integer32
  noOutletsTotal Integer32
  noSwitchedOutlets Integer32
  noMeasuredOutlets Integer32
  maximumLoad Integer32
  noTempSensors Integer32
  noEnvSensors Integer32

DeciAmps  
Data type for reporting measurements and thresholds associated with current sensors. If the underlying hardware sensor indicates 1.1 amp, then the SNMP agent will report a value of 11 DeciAmps. The value is scaled in this manner as a way to deal with floating point types that SNMP does not currently support.
TEXTUAL-CONVENTION    
  Integer32  

DeciCelsius  
Data type for reporting sensor readings associated with temperature sensors. If the underlying hardware sensor indicates 20.1 degree Celsius, then the SNMP agent will report a value of 201 tenth degrees Celsius. The value is scaled in this manner as a way to deal with floating point types that SNMP does not currently support.
TEXTUAL-CONVENTION    
  Integer32  

DeciPowerFactor  
Data type for reporting measurements associated with power factor calculation. The power factor of an AC power system is defined as the ratio of the real or active power to the apparent power and is a number between 0 and 1. A DeciPowerFactor value is calculated by taking this ratio and multiplying by 1000. A power factor of 98.3% will be reported as 983. The power factor is used to indicate how efficiently a particular load is utilizing energy.
TEXTUAL-CONVENTION    
  Integer32  

DeciValue  
Data type for reporting generic measurements associated with environmental sensors. If the underlying hardware sensor indicates 21.1 degree, then the SNMP agent will report a value of 211 DeciValue. The value is scaled in this manner as a way to deal with floating point types that SNMP does not currently support.
TEXTUAL-CONVENTION    
  Integer32  

DeciVolts  
Data type for reporting measurements and thresholds associated with voltage sensors. If the underlying hardware sensor indicates 231.1 volts, then the SNMP agent will report a value of 2311 DeciVolts. The value is scaled in this manner as a way to deal with floating point types that SNMP does not currently support.
TEXTUAL-CONVENTION    
  Integer32  

IdentificationEntry  
SEQUENCE    
  channelIndex1 Integer32
  spdmVersion Integer32
  firmwareVersion Integer32
  salesOrderNumber DisplayString
  productId DisplayString
  serialNumber DisplayString
  hardwareAddress DisplayString
  unitAddress Integer32
  busPosition Integer32

KiloWattHour  
Data type for reporting measurements associated with energy accumulation sensors. If the underlying hardware sensor indicates 1 kWh, then the SNMP agent will report a value of 1 kWh. No scaling is performed for this type.
TEXTUAL-CONVENTION    
  Integer32  

MilliSeconds  
The unit of duration for some settings
TEXTUAL-CONVENTION    
  Integer32  

Seconds  
The unit of duration for some settings
TEXTUAL-CONVENTION    
  Integer32  

SystemstatusEntry  
SEQUENCE    
  channelIndex3 Integer32
  deviceStatusCode Integer32
  temperatureAlert Integer32
  inputCurrentAlert Integer32
  outputCurrentAlert Integer32
  inputVoltageAlert Integer32
  oCurrentDropAlert Integer32
  iCurrentDropAlert Integer32

InputmeasuresEntry  
SEQUENCE    
  channelIndex6 Integer32
  kWhTotalI KiloWattHour
  kWhSubtotalI KiloWattHour
  powerFactorI DeciPowerFactor
  actualCurrentI DeciAmps
  peakCurrentI DeciAmps
  actualVoltageI DeciVolts
  minVoltageI DeciVolts
  powerVAI Integer32
  powerWattI Integer32
  maxInletAmps DeciAmps
  inputCTratio Integer32
  inputName DisplayString

OutletsEntry  
SEQUENCE    
  channelIndex4 Integer32
  outletName DisplayString

OutputmeasuresEntry  
SEQUENCE    
  channelIndex7 Integer32
  kWhTotalO KiloWattHour
  kWhSubtotalO KiloWattHour
  powerFactorO DeciPowerFactor
  actualCurrentO DeciAmps
  peakCurrentO DeciAmps
  actualVoltageO DeciVolts
  maxOutletAmps DeciAmps
  outputCTratio Integer32

SwitchedoutletsEntry  
SEQUENCE    
  channelIndex5 Integer32
  currentState Integer32
  scheduled Integer32
  unlock Integer32
  individualOutletDelay Seconds

SensorEntry  
SEQUENCE    
  channelIndex8 Integer32
  sensorType DisplayString
  sensorValue DeciValue
  sensorName DisplayString

Defined Values

schleifenbauer 1.3.6.1.4.1.31034
This MIB describes the functions of the Schleifenbauer device family.
MODULE-IDENTITY    

device0 1.3.6.1.4.1.31034.2
OBJECT IDENTIFIER    

identification 1.3.6.1.4.1.31034.2.3
OBJECT IDENTIFIER    

spdmVersion 1.3.6.1.4.1.31034.2.3.1
Data model version, currently 1.10
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..9999  

firmwareVersion 1.3.6.1.4.1.31034.2.3.2
The units firmware revision number.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..9999  

buildNumber 1.3.6.1.4.1.31034.2.3.3
Date and time of latest build of the firmware.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

salesOrderNumber 1.3.6.1.4.1.31034.2.3.4
SP sales order number.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

productId 1.3.6.1.4.1.31034.2.3.5
SP product id.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

serialNumber 1.3.6.1.4.1.31034.2.3.6
SP serial number.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

hardwareAddress 1.3.6.1.4.1.31034.2.3.7
Hardware serial number; cannot be changed. Can be used as backup unit address. format as 3 unsigned ints separated by dashes: int - int - int
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

macAddress 1.3.6.1.4.1.31034.2.3.8
The ethernet interfaces unique hardware address.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

unitAddress 1.3.6.1.4.1.31034.2.3.9
User defined address; this will be used for addressing the unit.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..65535  

deviceName 1.3.6.1.4.1.31034.2.3.10
User configurable device name or identifier.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

deviceLocation 1.3.6.1.4.1.31034.2.3.11
User configurable device location identifier.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

vanityTag 1.3.6.1.4.1.31034.2.3.12
Characters to be displayed as vanity tekst in display.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

configuration 1.3.6.1.4.1.31034.2.4
OBJECT IDENTIFIER    

noPhases 1.3.6.1.4.1.31034.2.4.1
Either zero, one or three for no input metering, single or three phase system
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..3  

noOutletsTotal 1.3.6.1.4.1.31034.2.4.2
Total number of outlets, even hardwired without switch/measure modules.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..99  

noSwitchedOutlets 1.3.6.1.4.1.31034.2.4.3
Number of switched outlets. If outlet numbering is non-contiguous: the highest outlet number.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..48  

noMeasuredOutlets 1.3.6.1.4.1.31034.2.4.4
Number of measured outlets. If outlet numbering is non-contiguous: the highest outlet number.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..48  

noSensors 1.3.6.1.4.1.31034.2.4.5
The number of external, digital environmental sensors: 0 for none, 1 to 16 depending on number of reported sensors
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..4  

maximumLoad 1.3.6.1.4.1.31034.2.4.6
Maximum rated load of device per phase, usually either 16 or 32 A.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..32  

systemstatus 1.3.6.1.4.1.31034.2.5
OBJECT IDENTIFIER    

deviceStatusCode 1.3.6.1.4.1.31034.2.5.1
Returns an internal status or error code. 0 = OK, 16 = watchdog timer caused reset, 128 = slave module was reset, 144 = both previous.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..255  

temperatureAlert 1.3.6.1.4.1.31034.2.5.2
An alert has been raised due to temperature exceeding treshhold; 0= no alert; 1= internal unit temp, 2= external sensor.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..2  

inputCurrentAlert 1.3.6.1.4.1.31034.2.5.3
An alert has been raised due to current exceeding treshhold; 0=no alert; 1-3 for input phase.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..3  

outputCurrentAlert 1.3.6.1.4.1.31034.2.5.4
An alert has been raised due to current exceeding treshhold; 0=no alert; 1-48 for outlet.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..48  

inputVoltageAlert 1.3.6.1.4.1.31034.2.5.5
An alert has been raised due to a voltage dip; 0=no alert; 1-3 for input phase.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..3  

oCurrentDropAlert 1.3.6.1.4.1.31034.2.5.6
An alert has been raised due to the current of a measured outlet suddenly dropping to near zero, possibly indicating a blown fuse; 0=no alert; 1-48 for outlet.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..103  

iCurrentDropAlert 1.3.6.1.4.1.31034.2.5.7
An alert has been raised due to the current of a measured input suddenly dropping to near zero, possibly indicating a blown fuse; 0=no alert; 1-3 for phase.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..3  

reset 1.3.6.1.4.1.31034.2.6
OBJECT IDENTIFIER    

rebootDevice 1.3.6.1.4.1.31034.2.6.1
Warm reboot/reset of device; note: this will have no effect on outlet status!
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

resetAlerts 1.3.6.1.4.1.31034.2.6.2
Reset all alert signals.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

zeroInputKWhSubtotal 1.3.6.1.4.1.31034.2.6.3
Reset of input kWh subtotal counters to zero.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

zeroOutKWhSubtotal 1.3.6.1.4.1.31034.2.6.4
Reset of outlet kWh subtotal counter to zero.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

resetPeakValues 1.3.6.1.4.1.31034.2.6.5
Reset all peak values to zero, as well input as output metering, voltages dips, current peaks and temperatures.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

settings 1.3.6.1.4.1.31034.2.7
OBJECT IDENTIFIER    

general 1.3.6.1.4.1.31034.2.7.1
OBJECT IDENTIFIER    

peakDuration 1.3.6.1.4.1.31034.2.7.1.4
A current peak should last at least [stpkdr] MilliSeconds before an alert is raised; max about a minute.
Status: current Access: read-write
OBJECT-TYPE    
  MilliSeconds  

fixedOutletDelay 1.3.6.1.4.1.31034.2.7.1.5
Minimal delay between two successive relay switches in milliseconds. Minimal delay is 100 ms. Will always be respected!
Status: current Access: read-write
OBJECT-TYPE    
  MilliSeconds  

powerSaverMode 1.3.6.1.4.1.31034.2.7.1.6
Set backlight on time in seconds; 0 keeps display always on. Note that keeping the backlight on may decrease luminosity over time. Setting this to other values than 10, 60, 120 or 240 is incompatible with the gateway!
Status: current Access: read-write
OBJECT-TYPE    
  Seconds  

outletPowerupMode 1.3.6.1.4.1.31034.2.7.1.7
Behaviour of outlet on power-up: 0=off; 1=same state as at power down; 2=same state, but delayed by individual delay timer.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..2  

maximumTemperature 1.3.6.1.4.1.31034.2.7.1.8
An alert should be generated whenever the temperature of the first connected T sensor is above this value. Zero means disabled.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..99  

displayOrientation 1.3.6.1.4.1.31034.2.7.1.9
0 no display; display off; 1 vertical, display on top; 2 vertical, upside down; 3 horizontal, display at left; 4 horizontal, display at right
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..4  

localAlertReset 1.3.6.1.4.1.31034.2.7.1.10
Allow alerts to be reset locally on device by pushing one of the buttons. [replaces dipDuration]
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

currentDropDetection 1.3.6.1.4.1.31034.2.7.1.11
Enables the current drop detection function. 0 = always off (default), 1 = input (s) only, 2 = output(s) only, 3 = both inputs and outputs.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..3  

wirelessDisplayPower 1.3.6.1.4.1.31034.2.7.1.12
Controls the transit power of the wireless display transciever (if installed). Set to zero to completely disable the module.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

inputmeasuresTable 1.3.6.1.4.1.31034.2.8
This table contains all measures related to the measured inputs of the DEVICE. Note: either 1 or 3 channels, depending on number of phases measured.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    InputmeasuresEntry

inputmeasuresEntry 1.3.6.1.4.1.31034.2.8.1
The record containing the registers for the channel selected by channelIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  InputmeasuresEntry  

channelIndex6 1.3.6.1.4.1.31034.2.8.1.1
The channel. Its value ranges between 1 and 48, depending on the number of channels, usually 1.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..48  

kWhTotalI 1.3.6.1.4.1.31034.2.8.1.2
Either the only phase in a single phase measurement; or one of the three phases in a multiphase measurement.
Status: current Access: read-only
OBJECT-TYPE    
  KiloWattHour  

kWhSubtotalI 1.3.6.1.4.1.31034.2.8.1.3
kWh subtotal register of the only phase in a single phase measurement; or one of three phases in a multiphase measurement. Reset to zero with [rsimks].
Status: current Access: read-only
OBJECT-TYPE    
  KiloWattHour  

powerFactorI 1.3.6.1.4.1.31034.2.8.1.4
The effective power factor in percent.
Status: current Access: read-only
OBJECT-TYPE    
  DeciPowerFactor  

actualCurrentI 1.3.6.1.4.1.31034.2.8.1.5
Actual apparent, RMS current.
Status: current Access: read-only
OBJECT-TYPE    
  DeciAmps  

peakCurrentI 1.3.6.1.4.1.31034.2.8.1.6
Peak apparent, RMS current; highest value since last reset of the alerts.
Status: current Access: read-only
OBJECT-TYPE    
  DeciAmps  

actualVoltageI 1.3.6.1.4.1.31034.2.8.1.7
The actual voltage.
Status: current Access: read-only
OBJECT-TYPE    
  DeciVolts  

minVoltageI 1.3.6.1.4.1.31034.2.8.1.8
RMS voltage dip; lowest value since reset of alerts.
Status: current Access: read-only
OBJECT-TYPE    
  DeciVolts  

powerVAI 1.3.6.1.4.1.31034.2.8.1.9
Power value calculated, not in data model of device.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

powerWattI 1.3.6.1.4.1.31034.2.8.1.10
Power value calculated by the gateway, not in data model of device.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

maxInletAmps 1.3.6.1.4.1.31034.2.8.1.11
Maximum current per input phase in A; should last at least [stpkdr] MilliSeconds before triggering an alert.
Status: current Access: read-write
OBJECT-TYPE    
  DeciAmps  

inputCTratio 1.3.6.1.4.1.31034.2.8.1.12
The multiplier to use in case of use of /5 current transformers. Defaults to 1.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

inputName 1.3.6.1.4.1.31034.2.8.1.13
User configurable naming of inputs or phases. Useful if channels are used to measure branches..
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

outletsTable 1.3.6.1.4.1.31034.2.9
This table contains the customer specific settings, determining toutlestablehe behaviour of the DEVICE.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OutletsEntry

outletsEntry 1.3.6.1.4.1.31034.2.9.1
The record containing the registers forthe channel selected by channelIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  OutletsEntry  

channelIndex4 1.3.6.1.4.1.31034.2.9.1.1
The channel. Its value ranges between 1 and 48, depending on the number of channels, usually 1.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..48  

outletName 1.3.6.1.4.1.31034.2.9.1.2
User configurable naming of individual outlets. Useful to distinguish outlets based on customer or device name.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

outputmeasuresTable 1.3.6.1.4.1.31034.2.10
This table contains all measures related to the measured outputs of the DEVICE. Note: up to 48 channels, depending on number of measured outlets.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OutputmeasuresEntry

outputmeasuresEntry 1.3.6.1.4.1.31034.2.10.1
The record containing the registers for the channel selected by channelIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  OutputmeasuresEntry  

channelIndex7 1.3.6.1.4.1.31034.2.10.1.1
The channel. Its value ranges between 1 and 48, depending on the number of channels, usually 1.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..48  

kWhTotalO 1.3.6.1.4.1.31034.2.10.1.2
Total kWh of selected output.
Status: current Access: read-only
OBJECT-TYPE    
  KiloWattHour  

kWhSubtotalO 1.3.6.1.4.1.31034.2.10.1.3
kWh subtotal register of selected output. Reset to zero with [rsomks].
Status: current Access: read-only
OBJECT-TYPE    
  KiloWattHour  

powerFactorO 1.3.6.1.4.1.31034.2.10.1.4
Power factor of output.
Status: current Access: read-only
OBJECT-TYPE    
  DeciPowerFactor  

actualCurrentO 1.3.6.1.4.1.31034.2.10.1.5
Actual apparent, RMS current.
Status: current Access: read-only
OBJECT-TYPE    
  DeciAmps  

peakCurrentO 1.3.6.1.4.1.31034.2.10.1.6
Peak apparent, RMS current; highest value since last reset of alerts.
Status: current Access: read-only
OBJECT-TYPE    
  DeciAmps  

actualVoltageO 1.3.6.1.4.1.31034.2.10.1.7
Actual voltage on output.
Status: current Access: read-only
OBJECT-TYPE    
  DeciVolts  

maxOutletAmps 1.3.6.1.4.1.31034.2.10.1.8
Maximum current per outlet in A; should last at least [stpkdr] MilliSeconds before triggering an alert.
Status: current Access: read-write
OBJECT-TYPE    
  DeciAmps  

outputCTratio 1.3.6.1.4.1.31034.2.10.1.9
The multiplier to use in case of use of /5 current transformers. Defaults to 1.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

switchedoutletsTable 1.3.6.1.4.1.31034.2.11
This table contains the current status of switchable DEVICE's.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SwitchedoutletsEntry

switchedoutletsEntry 1.3.6.1.4.1.31034.2.11.1
The record containing the registers for the channel selected by channelIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  SwitchedoutletsEntry  

channelIndex5 1.3.6.1.4.1.31034.2.11.1.1
The channel. Its value ranges between 1 and 48, depending on the number of channels, usually 1.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..48  

currentState 1.3.6.1.4.1.31034.2.11.1.2
The actual state of the outlet relays. The hardware will contain max 48 outlets. Writing is only effective after setting [swounl].
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..1  

scheduled 1.3.6.1.4.1.31034.2.11.1.3
A one indicates pending activity; the switch delay has not yet expired.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..1  

unlock 1.3.6.1.4.1.31034.2.11.1.4
Setting the value to one will release the safety for this outlet for a couple seconds; switching and rebooting are then temporarily enabled.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

individualOutletDelay 1.3.6.1.4.1.31034.2.11.1.5
Delay before an individual outlet switches on at power-up in Seconds.
Status: current Access: read-write
OBJECT-TYPE    
  Seconds  

sensorTable 1.3.6.1.4.1.31034.2.12
This table contains the environmental measurements. As well internal temperature as external temperature probes.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SensorEntry

sensorEntry 1.3.6.1.4.1.31034.2.12.1
The record containing the registers for the channel selected by channelIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  SensorEntry  

channelIndex8 1.3.6.1.4.1.31034.2.12.1.1
The channel. Its value ranges between 1 and 48, depending on the number of channels, usually 1.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..48  

sensorType 1.3.6.1.4.1.31034.2.12.1.2
Type of connected sensor, either T, H or I for respectively Temperature (C), Humidity (%) or dry switch contact
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

sensorValue 1.3.6.1.4.1.31034.2.12.1.3
Value of connected sensor
Status: current Access: read-only
OBJECT-TYPE    
  DeciValue  

sensorName 1.3.6.1.4.1.31034.2.12.1.4
User definable name for sensors.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

conformance 1.3.6.1.4.1.31034.99
OBJECT IDENTIFIER    

compliances 1.3.6.1.4.1.31034.99.1
OBJECT IDENTIFIER    

compliance 1.3.6.1.4.1.31034.99.1.1
The requirements for conformance to the SPGW-MIB.
Status: current Access: read-write
MODULE-COMPLIANCE    

groups 1.3.6.1.4.1.31034.99.2
OBJECT IDENTIFIER    

identificationGroup 1.3.6.1.4.1.31034.99.2.1
A collection of objects providing identification information about the device.
Status: current Access: read-write
OBJECT-GROUP    

configurationGroup 1.3.6.1.4.1.31034.99.2.2
A collection of objects providing configuration information about the device.
Status: current Access: read-write
OBJECT-GROUP    

systemStatusGroup 1.3.6.1.4.1.31034.99.2.3
A collection of objects providing status information about the device.
Status: current Access: read-write
OBJECT-GROUP    

resetGroup 1.3.6.1.4.1.31034.99.2.4
Groups resettable attributes op the device.
Status: current Access: read-write
OBJECT-GROUP    

settingsGroup 1.3.6.1.4.1.31034.99.2.5
A collection of objects providing the actual settings about the device.
Status: current Access: read-write
OBJECT-GROUP    

switchedOutletsGroup 1.3.6.1.4.1.31034.99.2.6
A collection of objects providing the actual outlet status of the device.
Status: current Access: read-write
OBJECT-GROUP    

inputMeasuresGroup 1.3.6.1.4.1.31034.99.2.7
A collection of objects providing the actual input measurements of the device.
Status: current Access: read-write
OBJECT-GROUP    

outputMeasuresGroup 1.3.6.1.4.1.31034.99.2.8
A collection of objects providing the actual output measurements of the device.
Status: current Access: read-write
OBJECT-GROUP    

sensorsGroup 1.3.6.1.4.1.31034.99.2.9
A collection of objects providing the actual environmental measurements of the device.
Status: current Access: read-write
OBJECT-GROUP