SCHLEIFENBAUER-DATABUS-MIB

File: SCHLEIFENBAUER-DATABUS-MIB.mib (60874 bytes)

Imported modules

SNMPv2-SMI SNMPv2-CONF SNMPv2-TC
SCHLEIFENBAUER-SMI

Imported symbols

MODULE-IDENTITY OBJECT-TYPE Integer32
NOTIFICATION-TYPE OBJECT-GROUP NOTIFICATION-GROUP
MODULE-COMPLIANCE TEXTUAL-CONVENTION DisplayString
schleifenbauerMgmt

Defined Types

DeciValue  
Data type for reporting generic measurements associated with environmental sensors. If the underlying hardware sensor indicates 21.1 degrees Celsius, then the SNMP agent will report a value of 2110 DeciValue.
TEXTUAL-CONVENTION    
  Integer32 0..327680  

KiloWattHour  
Data type for reporting measurements associated with energy accumulation sensors. If the underlying hardware sensor indicates 1 kWh, then the SNMP agent will report a value of 1 kWh.
TEXTUAL-CONVENTION    
  Integer32 0..16777215  

DeciAmpere  
Data type for reporting measurements and thresholds associated with current sensors. If the underlying hardware sensor indicates 1.1 A, then the SNMP agent will report a value of 110 DeciAmpere.
TEXTUAL-CONVENTION    
  Integer32 0..327680  

DeciCelsius  
Data type for reporting sensor readings associated with temperature sensors. If the underlying hardware sensor indicates 20.1 degrees Celsius, then the SNMP agent will report a value of 2010 DeciCelsius.
TEXTUAL-CONVENTION    
  Integer32 0..9900  

DeciPercent  
Data type for reporting calculated percentages. If the calculated percentage is 98.3%, then the SNMP agent will report a value of 9830 DeciPercent.
TEXTUAL-CONVENTION    
  Integer32 0..10000  

DeciVolt  
Data type for reporting measurements and thresholds associated with voltage sensors. If the underlying hardware sensor indicates 231.1 V, then the SNMP agent will report a value of 23110 DeciVolt.
TEXTUAL-CONVENTION    
  Integer32 0..327680  

MilliSecond  
Duration in milliseconds
TEXTUAL-CONVENTION    
  Integer32  

Second  
Duration in seconds.
TEXTUAL-CONVENTION    
  Integer32  

SdbMgmtCtrlDevicesEntry  
SEQUENCE    
  sdbMgmtCtrlDevIndex Integer32
  sdbMgmtCtrlDevUnitAddress Integer32
  sdbMgmtCtrlDevHardwareAddress DisplayString
  sdbMgmtCtrlDevIsNew Integer32
  sdbMgmtCtrlDevIsDuplicate Integer32

SdbDevIdEntry  
SEQUENCE    
  sdbDevIdSPDMVersion Integer32
  sdbDevIdFirmwareVersion Integer32
  sdbDevIdBuildNumber DisplayString
  sdbDevIdSalesOrderNumber DisplayString
  sdbDevIdProductId DisplayString
  sdbDevIdSerialNumber DisplayString
  sdbDevIdHardwareAddress DisplayString
  sdbDevIdMacAddress DisplayString
  sdbDevIdUnitAddress Integer32
  sdbDevIdName DisplayString
  sdbDevIdLocation DisplayString
  sdbDevIdVanityTag DisplayString
  sdbDevIdIndex Integer32

SdbDevCfEntry  
SEQUENCE    
  sdbDevCfPhases Integer32
  sdbDevCfOutletsTotal Integer32
  sdbDevCfOutletsSwitched Integer32
  sdbDevCfOutletsMetered Integer32
  sdbDevCfSensors Integer32
  sdbDevCfMaximumLoad Integer32

SdbDevSsEntry  
SEQUENCE    
  sdbDevSsDeviceStatusCode Integer32
  sdbDevSsTemperatureAlert Integer32
  sdbDevSsInputCurrentAlert Integer32
  sdbDevSsOutletCurrentAlert Integer32
  sdbDevSsInputVoltageAlert Integer32
  sdbDevSsOutletCurrentDropAlert Integer32
  sdbDevSsInputCurrentDropAlert Integer32
  sdbDevSsSensorChangeAlert Integer32
  sdbDevSsOutletVoltageDropAlert Integer32

SdbDevRsEntry  
SEQUENCE    
  sdbDevRsReboot Integer32
  sdbDevRsResetAlerts Integer32
  sdbDevRsZeroInputKWhSubtotal Integer32
  sdbDevRsZeroOutletKWhSubtotal Integer32
  sdbDevRsResetPeaksAndDips Integer32

SdbDevStEntry  
SEQUENCE    
  sdbDevStAutoResetAlerts Integer32
  sdbDevStExtendedNames Integer32
  sdbDevStPeakDuration MilliSecond
  sdbDevStFixedOutletDelay MilliSecond
  sdbDevStPowerSaverMode Second
  sdbDevStOutletPowerUpMode Integer32
  sdbDevStMaximumTemperature Integer32
  sdbDevStDisplayOrientation Integer32
  sdbDevStLocalAlertReset Integer32
  sdbDevStCurrentDropDetection Integer32

SdbDevInEntry  
SEQUENCE    
  sdbDevInIndex Integer32
  sdbDevInKWhTotal KiloWattHour
  sdbDevInKWhSubtotal KiloWattHour
  sdbDevInPowerFactor DeciPercent
  sdbDevInActualCurrent DeciAmpere
  sdbDevInPeakCurrent DeciAmpere
  sdbDevInActualVoltage DeciVolt
  sdbDevInMinVoltage DeciVolt
  sdbDevInPowerVoltAmpere Integer32
  sdbDevInPowerWatt Integer32
  sdbDevInMaxAmps DeciAmpere
  sdbDevInCTRatio Integer32
  sdbDevInName DisplayString
  sdbDevInZeroKWhSubtotal Integer32

SdbDevOutEntry  
SEQUENCE    
  sdbDevOutIndex Integer32
  sdbDevOutName DisplayString

SdbDevOutMtEntry  
SEQUENCE    
  sdbDevOutMtIndex Integer32
  sdbDevOutMtKWhTotal KiloWattHour
  sdbDevOutMtKWhSubtotal KiloWattHour
  sdbDevOutMtPowerFactor DeciPercent
  sdbDevOutMtActualCurrent DeciAmpere
  sdbDevOutMtPeakCurrent DeciAmpere
  sdbDevOutMtActualVoltage DeciVolt
  sdbDevOutMtMaxAmps DeciAmpere
  sdbDevOutMtCTRatio Integer32
  sdbDevOutMtPowerVoltAmpere Integer32
  sdbDevOutMtPowerWatt Integer32

SdbDevOutSwEntry  
SEQUENCE    
  sdbDevOutSwIndex Integer32
  sdbDevOutSwCurrentState Integer32
  sdbDevOutSwScheduled Integer32
  sdbDevOutSwUnlock Integer32
  sdbDevOutSwIndividualOutletDelay Second
  sdbDevOutSwReboot Integer32

SdbDevMeasuresEntry  
SEQUENCE    
  sdbDevMsIntTemperature DeciCelsius
  sdbDevMsExtTemperature DeciCelsius
  sdbDevMsIntTemperaturePeak DeciCelsius
  sdbDevMsExtTemperaturePeak DeciCelsius

SdbDevSnsEntry  
SEQUENCE    
  sdbDevSnsIndex Integer32
  sdbDevSnsType DisplayString
  sdbDevSnsValue DeciValue
  sdbDevSnsName DisplayString

Defined Values

schleifenbauerDatabusMIB 1.3.6.1.4.1.31034.12.1
This MIB describes the SNMP functions of network enabled databus devices. Copyright (c) 2016 by Schleifenbauer Holding BV
MODULE-IDENTITY    

sdbMIBNotifications 1.3.6.1.4.1.31034.12.1.0
OBJECT IDENTIFIER    

sdbMIBObjects 1.3.6.1.4.1.31034.12.1.1
OBJECT IDENTIFIER    

sdbMIBConformance 1.3.6.1.4.1.31034.12.1.2
OBJECT IDENTIFIER    

sdbMgmt 1.3.6.1.4.1.31034.12.1.1.1
OBJECT IDENTIFIER    

sdbDevice 1.3.6.1.4.1.31034.12.1.1.2
OBJECT IDENTIFIER    

sdbMgmtStatus 1.3.6.1.4.1.31034.12.1.1.1.1
OBJECT IDENTIFIER    

sdbMgmtControl 1.3.6.1.4.1.31034.12.1.1.1.2
OBJECT IDENTIFIER    

sdbDevIdentification 1.3.6.1.4.1.31034.12.1.1.2.1
OBJECT IDENTIFIER    

sdbDevConfiguration 1.3.6.1.4.1.31034.12.1.1.2.2
OBJECT IDENTIFIER    

sdbDevSystemStatus 1.3.6.1.4.1.31034.12.1.1.2.3
OBJECT IDENTIFIER    

sdbDevReset 1.3.6.1.4.1.31034.12.1.1.2.4
OBJECT IDENTIFIER    

sdbDevSettings 1.3.6.1.4.1.31034.12.1.1.2.5
OBJECT IDENTIFIER    

sdbDevInput 1.3.6.1.4.1.31034.12.1.1.2.6
OBJECT IDENTIFIER    

sdbDevOutlet 1.3.6.1.4.1.31034.12.1.1.2.7
OBJECT IDENTIFIER    

sdbDevSensor 1.3.6.1.4.1.31034.12.1.1.2.8
OBJECT IDENTIFIER    

sdbMIBCompliances 1.3.6.1.4.1.31034.12.1.2.1
OBJECT IDENTIFIER    

sdbMIBGroups 1.3.6.1.4.1.31034.12.1.2.2
OBJECT IDENTIFIER    

sdbMgmtStsDevices 1.3.6.1.4.1.31034.12.1.1.1.1.1
The number of devices on the databus.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..512  

sdbMgmtStsAddressableDevices 1.3.6.1.4.1.31034.12.1.1.1.1.2
The number of devices on the databus addressable by snmp.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

sdbMgmtStsNewDevices 1.3.6.1.4.1.31034.12.1.1.1.1.3
The number of new devices on the databus.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

sdbMgmtStsDuplicateDevices 1.3.6.1.4.1.31034.12.1.1.1.1.4
The number of duplicate devices on the databus.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

sdbMgmtStsRingState 1.3.6.1.4.1.31034.12.1.1.1.1.5
If the device is in a bridge-like mode, this will indicate the actual state of the databus.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER open(0), closed(1)  

sdbMgmtStsRingBreachIndex 1.3.6.1.4.1.31034.12.1.1.1.1.6
Indicates the breach index if the current state of the data bus is open. If the data bus is closed this has no meaning.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..65535  

sdbMgmtCtrlScan 1.3.6.1.4.1.31034.12.1.1.1.2.1
Perform a bus scan. To verify if scanning is completed the value of this object can be read. During the bus scan the value remains 1. When the bus scan completed the value will be 0.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER idle(0), scan(1)  

sdbMgmtCtrlRenumberAllFromN 1.3.6.1.4.1.31034.12.1.1.1.2.2
Renumber all devices on the databus. If set to 0 all units will be set to 0. If set to another value, all units will be numbered in sequence starting from the value set.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..65535  

sdbMgmtCtrlRenumberZeros 1.3.6.1.4.1.31034.12.1.1.1.2.3
Renumber all devices on the databus having address 0. Renumbering will be done in sequence. The sequence starts with the highest address found on the databus.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER idle(0), renumber(1)  

sdbMgmtCtrlDevicesTable 1.3.6.1.4.1.31034.12.1.1.1.2.4
A table containing information of devices connected to the databus. The number of entries is given by the value of sdbMgmtStsDevices.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SdbMgmtCtrlDevicesEntry

sdbMgmtCtrlDevicesEntry 1.3.6.1.4.1.31034.12.1.1.1.2.4.1
Information entry containing objects of a particular databus device.
Status: current Access: not-accessible
OBJECT-TYPE    
  SdbMgmtCtrlDevicesEntry  

sdbMgmtCtrlDevIndex 1.3.6.1.4.1.31034.12.1.1.1.2.4.1.1
A unique value for each device. Its value ranges between 1 and the value of sdbMgmtStsDevices with a maximum of 255. The value for each device will remain constant until the next scan is performed.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..255  

sdbMgmtCtrlDevUnitAddress 1.3.6.1.4.1.31034.12.1.1.1.2.4.1.2
User defined address. This will be used for addressing the device on the databus.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..65535  

sdbMgmtCtrlDevHardwareAddress 1.3.6.1.4.1.31034.12.1.1.1.2.4.1.3
Hardware serial number. This cannot be changed. It can be used as backup unit address. format as 3 unsigned ints separated by dashes: int - int - int
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(17)  

sdbMgmtCtrlDevIsNew 1.3.6.1.4.1.31034.12.1.1.1.2.4.1.4
Indication if the device is new on the databus.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER no(0), yes(1)  

sdbMgmtCtrlDevIsDuplicate 1.3.6.1.4.1.31034.12.1.1.1.2.4.1.5
Indication if the device is conflicting with another device on the databus.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER no(0), yes(1)  

sdbDevIdTable 1.3.6.1.4.1.31034.12.1.1.2.1.1
A table containing identification information of devices connected to the databus. The number of entries is given by the value of sdbMgmtStsAddressableDevices.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SdbDevIdEntry

sdbDevIdEntry 1.3.6.1.4.1.31034.12.1.1.2.1.1.1
Information entry containing information objects of a particular databus device.
Status: current Access: not-accessible
OBJECT-TYPE    
  SdbDevIdEntry  

sdbDevIdSPDMVersion 1.3.6.1.4.1.31034.12.1.1.2.1.1.1.1
Data model version.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..9999  

sdbDevIdFirmwareVersion 1.3.6.1.4.1.31034.12.1.1.2.1.1.1.2
The firmware revision number.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..9999  

sdbDevIdBuildNumber 1.3.6.1.4.1.31034.12.1.1.2.1.1.1.3
Date and time the firmware was built.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..12)  

sdbDevIdSalesOrderNumber 1.3.6.1.4.1.31034.12.1.1.2.1.1.1.4
SP sales order number.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..16)  

sdbDevIdProductId 1.3.6.1.4.1.31034.12.1.1.2.1.1.1.5
SP product id.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..16)  

sdbDevIdSerialNumber 1.3.6.1.4.1.31034.12.1.1.2.1.1.1.6
SP serial number.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..16)  

sdbDevIdHardwareAddress 1.3.6.1.4.1.31034.12.1.1.2.1.1.1.7
Hardware serial number. This can not be changed. It can be used as backup unit address. Format as 3 unsigned ints separated by dashes (-) e.g. 12345-54321-00000
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(17)  

sdbDevIdMacAddress 1.3.6.1.4.1.31034.12.1.1.2.1.1.1.8
The MAC address. This can not be changed. It represents an 802 MAC address as if it were transmitted least significant bit first. Format as six groups of 2 hexadecimal digits separated by colons (:) e.g. D0:22:12:B0:00:00
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(17)  

sdbDevIdUnitAddress 1.3.6.1.4.1.31034.12.1.1.2.1.1.1.9
User defined address. This will be used for addressing the device on the databus.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..65535  

sdbDevIdName 1.3.6.1.4.1.31034.12.1.1.2.1.1.1.10
User configurable device name or identifier.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..16)  

sdbDevIdLocation 1.3.6.1.4.1.31034.12.1.1.2.1.1.1.11
User configurable device location identifier.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..16)  

sdbDevIdVanityTag 1.3.6.1.4.1.31034.12.1.1.2.1.1.1.12
Characters to be displayed as vanity text in display.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..20)  

sdbDevIdIndex 1.3.6.1.4.1.31034.12.1.1.2.1.1.1.13
A unique value for each device. Its value represents the unit address of the device and is used to address individual devices in the tree. The value for each device will remain constant until the next scan is performed.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..65535  

sdbDevCfTable 1.3.6.1.4.1.31034.12.1.1.2.2.1
A table containing configuration information of devices connected to the databus. The number of entries is given by the value of sdbMgmtStsAddressableDevices.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SdbDevCfEntry

sdbDevCfEntry 1.3.6.1.4.1.31034.12.1.1.2.2.1.1
Configuration entry containing configuration objects of a particular databus device.
Status: current Access: not-accessible
OBJECT-TYPE    
  SdbDevCfEntry  

sdbDevCfPhases 1.3.6.1.4.1.31034.12.1.1.2.2.1.1.1
Number of phases for input metering.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0 | 1 | 3  

sdbDevCfOutletsTotal 1.3.6.1.4.1.31034.12.1.1.2.2.1.1.2
Total number of outlets including hardwired without switch/metered modules.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..48  

sdbDevCfOutletsSwitched 1.3.6.1.4.1.31034.12.1.1.2.2.1.1.3
Number of switched outlets. If outlet numbering is non-contiguous its the highest outlet number.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..48  

sdbDevCfOutletsMetered 1.3.6.1.4.1.31034.12.1.1.2.2.1.1.4
Number of metered outlets. If outlet numbering is non-contiguous its the highest outlet number.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..48  

sdbDevCfSensors 1.3.6.1.4.1.31034.12.1.1.2.2.1.1.5
The number sensors.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..16  

sdbDevCfMaximumLoad 1.3.6.1.4.1.31034.12.1.1.2.2.1.1.6
Maximum rated load of device per phase
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 16 | 32  

sdbDevSsTable 1.3.6.1.4.1.31034.12.1.1.2.3.1
A table containing system status information of devices connected to the databus. The number of entries is given by the value of sdbMgmtStsAddressableDevices.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SdbDevSsEntry

sdbDevSsEntry 1.3.6.1.4.1.31034.12.1.1.2.3.1.1
System status entry containing system status objects of a particular databus device.
Status: current Access: not-accessible
OBJECT-TYPE    
  SdbDevSsEntry  

sdbDevSsDeviceStatusCode 1.3.6.1.4.1.31034.12.1.1.2.3.1.1.1
Returns an internal status or error code. A value of 0 means OK. If not 0 it can be any of the following codes. Multiple status codes can be active at the same time. The value will be the sum of the active status codes. 1 = alert flagged 2 = settings(s) initialized 4 = power-on reset 8 = external reset 16 = watchdog timer caused reset 32 = brownout detected 64 = controller error 128 = slave module was reset
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..255  

sdbDevSsTemperatureAlert 1.3.6.1.4.1.31034.12.1.1.2.3.1.1.2
An alert has been raised due to temperature exceeding treshhold. 0 = no alert 1 = internal temperature sensor 2 = external temperature sensor
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..2  

sdbDevSsInputCurrentAlert 1.3.6.1.4.1.31034.12.1.1.2.3.1.1.3
An alert has been raised due to current exceeding treshhold. The value indicates the exceeding phase. 0 = no alert.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..3  

sdbDevSsOutletCurrentAlert 1.3.6.1.4.1.31034.12.1.1.2.3.1.1.4
An alert has been raised due to current exceeding treshhold. The value indicates the exceeding outlet. 0 = no alert.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..48  

sdbDevSsInputVoltageAlert 1.3.6.1.4.1.31034.12.1.1.2.3.1.1.5
An alert has been raised due to a voltage dip. The value indicates the dipped phase. 0 = no alert.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..3  

sdbDevSsOutletCurrentDropAlert 1.3.6.1.4.1.31034.12.1.1.2.3.1.1.6
An alert has been raised due to the current of a metered outlet suddenly dropping to near zero, possibly indicating a blown fuse. The value indicates the dropped outlet. 0 = no alert.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..48  

sdbDevSsInputCurrentDropAlert 1.3.6.1.4.1.31034.12.1.1.2.3.1.1.7
An alert has been raised due to the current of a metered input suddenly dropping to near zero, possibly indicating a blown fuse. The value indicates the dropped phase. 0 = no alert.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..3  

sdbDevSsSensorChangeAlert 1.3.6.1.4.1.31034.12.1.1.2.3.1.1.8
An alert has been raised due to a change in the number of sensors. The value indicates the previous amount of sensors.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..16  

sdbDevSsOutletVoltageDropAlert 1.3.6.1.4.1.31034.12.1.1.2.3.1.1.9
An alert has been raised due to voltage drop on this outlet. The value indicates the first failed outlet.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..48  

sdbDevRsTable 1.3.6.1.4.1.31034.12.1.1.2.4.1
A table providing reset capabilities to devices connected to the databus. The number of entries is given by the value of sdbMgmtStsAddressableDevices.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SdbDevRsEntry

sdbDevRsEntry 1.3.6.1.4.1.31034.12.1.1.2.4.1.1
Reset entry providing reset objects of a particular databus device.
Status: current Access: not-accessible
OBJECT-TYPE    
  SdbDevRsEntry  

sdbDevRsReboot 1.3.6.1.4.1.31034.12.1.1.2.4.1.1.1
Warm reboot/reset of device controller. NOTE: this will have NO effect on outlet status!
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER idle(0), reboot(1)  

sdbDevRsResetAlerts 1.3.6.1.4.1.31034.12.1.1.2.4.1.1.2
Reset all alert signals and device status code.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER idle(0), reset(1)  

sdbDevRsZeroInputKWhSubtotal 1.3.6.1.4.1.31034.12.1.1.2.4.1.1.3
Reset of all input kWh subtotal counters to zero.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER idle(0), zero(1)  

sdbDevRsZeroOutletKWhSubtotal 1.3.6.1.4.1.31034.12.1.1.2.4.1.1.4
Reset of all outlet kWh subtotal counter to zero.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER idle(0), zero(1)  

sdbDevRsResetPeaksAndDips 1.3.6.1.4.1.31034.12.1.1.2.4.1.1.5
Reset all peak and dip values to zero.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER idle(0), reset(1)  

sdbDevStTable 1.3.6.1.4.1.31034.12.1.1.2.5.1
A table containing setting information of devices connected to the databus. The number of entries is given by the value of sdbMgmtStsAddressableDevices.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SdbDevStEntry

sdbDevStEntry 1.3.6.1.4.1.31034.12.1.1.2.5.1.1
Setting entry containing settings objects of a particular databus device.
Status: current Access: not-accessible
OBJECT-TYPE    
  SdbDevStEntry  

sdbDevStAutoResetAlerts 1.3.6.1.4.1.31034.12.1.1.2.5.1.1.2
Auto reset alerts configuration. If set to 0 the auto reset alerts feature is disabled. If set to a value greater then 0, the auto reset alerts feature is enabled and alerts will get cleared after the configured amount of seconds since the last alert condition have passed.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..65535  

sdbDevStExtendedNames 1.3.6.1.4.1.31034.12.1.1.2.5.1.1.3
Use original or longer names for inputs, outlets and sensors.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

sdbDevStPeakDuration 1.3.6.1.4.1.31034.12.1.1.2.5.1.1.4
Amount of ms a current peak should last before an alert is raised.
Status: current Access: read-write
OBJECT-TYPE    
  MilliSecond 0..65535  

sdbDevStFixedOutletDelay 1.3.6.1.4.1.31034.12.1.1.2.5.1.1.5
Minimal delay between two successive relay switches in milliseconds. Minimal delay is 100 ms. Will always be respected!
Status: current Access: read-write
OBJECT-TYPE    
  MilliSecond 100..65535  

sdbDevStPowerSaverMode 1.3.6.1.4.1.31034.12.1.1.2.5.1.1.6
Set backlight on time in seconds. 0 keeps display always on. Note that keeping the backlight on may decrease luminosity over time.
Status: current Access: read-write
OBJECT-TYPE    
  Second 0 | 10 | 60 | 120 | 240  

sdbDevStOutletPowerUpMode 1.3.6.1.4.1.31034.12.1.1.2.5.1.1.7
Behaviour of outlets on power-up.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(0), sameState(1), sameStateDelayed(2)  

sdbDevStMaximumTemperature 1.3.6.1.4.1.31034.12.1.1.2.5.1.1.8
Maximum temperature threshold An alert will be generated whenever the temperature is above this value. Zero means disabled.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..99  

sdbDevStDisplayOrientation 1.3.6.1.4.1.31034.12.1.1.2.5.1.1.9
Display orientation.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noDisplay(0), verticalDisplayOnTop(1), verticalDisplayUpsideDown(2), horizontalDisplayAtLeft(3), horizontalDisplayAtRight(4)  

sdbDevStLocalAlertReset 1.3.6.1.4.1.31034.12.1.1.2.5.1.1.10
Allow alerts to be reset locally on device by pushing one of the buttons.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notAllowed(0), allowed(1)  

sdbDevStCurrentDropDetection 1.3.6.1.4.1.31034.12.1.1.2.5.1.1.11
Enables the current drop detection function.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(0), inputsOnly(1), outletsOnly(2), inputsAndOutlets(3)  

sdbDevInTable 1.3.6.1.4.1.31034.12.1.1.2.6.1
A table containing information of inputs of devices connected to the databus.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SdbDevInEntry

sdbDevInEntry 1.3.6.1.4.1.31034.12.1.1.2.6.1.1
Inputs entry containing objects of an input of a particular databus device. Note that this table has two indexes. sdbDevIdIndex to identify a particular device and sdbDevInIndex to identify a particular input of the device identified by sdbDevIdIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  SdbDevInEntry  

sdbDevInIndex 1.3.6.1.4.1.31034.12.1.1.2.6.1.1.1
A unique value for each input. Its value ranges between 1 and the value of sdbDevCfPhases.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..48  

sdbDevInKWhTotal 1.3.6.1.4.1.31034.12.1.1.2.6.1.1.2
Total kWh value of an input. This value can not be reset.
Status: current Access: read-only
OBJECT-TYPE    
  KiloWattHour  

sdbDevInKWhSubtotal 1.3.6.1.4.1.31034.12.1.1.2.6.1.1.3
Subtotal kWh value of an input. This value can be reset.
Status: current Access: read-only
OBJECT-TYPE    
  KiloWattHour  

sdbDevInPowerFactor 1.3.6.1.4.1.31034.12.1.1.2.6.1.1.4
Power factor of input. The power factor of an AC power system is defined as the ratio of the real or active power to the apparent power and is a number between 0 and 1. This value is expressed as a percentage between 0% and 100%.
Status: current Access: read-only
OBJECT-TYPE    
  DeciPercent  

sdbDevInActualCurrent 1.3.6.1.4.1.31034.12.1.1.2.6.1.1.5
Actual apparent, RMS current.
Status: current Access: read-only
OBJECT-TYPE    
  DeciAmpere  

sdbDevInPeakCurrent 1.3.6.1.4.1.31034.12.1.1.2.6.1.1.6
Peak apparent, RMS current. Highest value since last reset of the alerts.
Status: current Access: read-only
OBJECT-TYPE    
  DeciAmpere  

sdbDevInActualVoltage 1.3.6.1.4.1.31034.12.1.1.2.6.1.1.7
The actual voltage.
Status: current Access: read-only
OBJECT-TYPE    
  DeciVolt  

sdbDevInMinVoltage 1.3.6.1.4.1.31034.12.1.1.2.6.1.1.8
RMS voltage dip. Lowest value since reset of alerts.
Status: current Access: read-only
OBJECT-TYPE    
  DeciVolt  

sdbDevInPowerVoltAmpere 1.3.6.1.4.1.31034.12.1.1.2.6.1.1.9
Calculated apparent power.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..327680  

sdbDevInPowerWatt 1.3.6.1.4.1.31034.12.1.1.2.6.1.1.10
Calculated real power.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..327680  

sdbDevInMaxAmps 1.3.6.1.4.1.31034.12.1.1.2.6.1.1.11
Maximum current per input phase. Should last at least sdbDevStPeakDuration ms before triggering an alert.
Status: current Access: read-write
OBJECT-TYPE    
  DeciAmpere  

sdbDevInCTRatio 1.3.6.1.4.1.31034.12.1.1.2.6.1.1.12
The multiplier to use for the input CTs.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..255  

sdbDevInName 1.3.6.1.4.1.31034.12.1.1.2.6.1.1.13
User configurable naming of inputs or phases.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..8)  

sdbDevInZeroKWhSubtotal 1.3.6.1.4.1.31034.12.1.1.2.6.1.1.14
Reset input kWh subtotal counter of a single input to zero.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER idle(0), zero(1)  

sdbDevOutTable 1.3.6.1.4.1.31034.12.1.1.2.7.1
A table containing information of outlets of devices connected to the databus.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SdbDevOutEntry

sdbDevOutEntry 1.3.6.1.4.1.31034.12.1.1.2.7.1.1
Outlets entry containing objects of an outlet of a particular databus device. Note that this table has two indexes. sdbDevIdIndex to identify a particular device and sdbDevOutIndex to identify a particular outlet of the device identified by sdbDevIdIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  SdbDevOutEntry  

sdbDevOutIndex 1.3.6.1.4.1.31034.12.1.1.2.7.1.1.1
A unique value for each outlet. Its value ranges between 1 and the value of sdbDevCfOutletsTotal.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..48  

sdbDevOutName 1.3.6.1.4.1.31034.12.1.1.2.7.1.1.2
User configurable naming of individual outlets.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..8)  

sdbDevOutMtTable 1.3.6.1.4.1.31034.12.1.1.2.7.2
A table containing information of metered outlets of devices connected to the databus.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SdbDevOutMtEntry

sdbDevOutMtEntry 1.3.6.1.4.1.31034.12.1.1.2.7.2.1
Metered outlets entry containing objects of a metered outlet of a particular databus device. Note that this table has two indexes. sdbDevIdIndex to identify a particular device and sdbDevOutMtIndex to identify a particular outlet of the device identified by sdbDevIdIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  SdbDevOutMtEntry  

sdbDevOutMtIndex 1.3.6.1.4.1.31034.12.1.1.2.7.2.1.1
A unique value for each outlet. Its value ranges between 1 and the value of sdbDevCfOutletsMetered.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..48  

sdbDevOutMtKWhTotal 1.3.6.1.4.1.31034.12.1.1.2.7.2.1.2
Total kWh value of an outlet. This value can not be reset.
Status: current Access: read-only
OBJECT-TYPE    
  KiloWattHour  

sdbDevOutMtKWhSubtotal 1.3.6.1.4.1.31034.12.1.1.2.7.2.1.3
Subotal kWh value of an outlet. This value can be reset.
Status: current Access: read-only
OBJECT-TYPE    
  KiloWattHour  

sdbDevOutMtPowerFactor 1.3.6.1.4.1.31034.12.1.1.2.7.2.1.4
Power factor of outlet. The power factor of an AC power system is defined as the ratio of the real or active power to the apparent power and is a number between 0 and 1. This number is expressed as a percentage between 0% and 100%.
Status: current Access: read-only
OBJECT-TYPE    
  DeciPercent  

sdbDevOutMtActualCurrent 1.3.6.1.4.1.31034.12.1.1.2.7.2.1.5
Actual apparent, RMS current.
Status: current Access: read-only
OBJECT-TYPE    
  DeciAmpere  

sdbDevOutMtPeakCurrent 1.3.6.1.4.1.31034.12.1.1.2.7.2.1.6
Peak apparent, RMS current. Highest value since last reset of the alerts.
Status: current Access: read-only
OBJECT-TYPE    
  DeciAmpere  

sdbDevOutMtActualVoltage 1.3.6.1.4.1.31034.12.1.1.2.7.2.1.7
Actual voltage on outlet.
Status: current Access: read-only
OBJECT-TYPE    
  DeciVolt  

sdbDevOutMtMaxAmps 1.3.6.1.4.1.31034.12.1.1.2.7.2.1.8
Maximum current per outlet. Should last at least sdbDevStPeakDuration ms before triggering an alert.
Status: current Access: read-write
OBJECT-TYPE    
  DeciAmpere  

sdbDevOutMtCTRatio 1.3.6.1.4.1.31034.12.1.1.2.7.2.1.9
The multiplier to use for the outlet CTs.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..255  

sdbDevOutMtPowerVoltAmpere 1.3.6.1.4.1.31034.12.1.1.2.7.2.1.10
Calculated apparent power.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..327680  

sdbDevOutMtPowerWatt 1.3.6.1.4.1.31034.12.1.1.2.7.2.1.11
Calculated real power.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..327680  

sdbDevOutSwTable 1.3.6.1.4.1.31034.12.1.1.2.7.3
A table containing information of switched outlets of devices connected to the databus.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SdbDevOutSwEntry

sdbDevOutSwEntry 1.3.6.1.4.1.31034.12.1.1.2.7.3.1
Switched outlets entry containing objects of a switched outlet of a particular databus device. Note that this table has two indexes. sdbDevIdIndex to identify a particular device and sdbDevOutSwIndex to identify a particular outlet of the device identified by sdbDevIdIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  SdbDevOutSwEntry  

sdbDevOutSwIndex 1.3.6.1.4.1.31034.12.1.1.2.7.3.1.1
A unique value for each outlet. Its value ranges between 1 and the value of sdbDevCfOutletsSwitched.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..48  

sdbDevOutSwCurrentState 1.3.6.1.4.1.31034.12.1.1.2.7.3.1.2
The actual state of the outlet relay. Note that Writing is only effective after setting sdbDevOutSwUnlock.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(0), on(1)  

sdbDevOutSwScheduled 1.3.6.1.4.1.31034.12.1.1.2.7.3.1.3
A one indicates pending activity; the switch delay has not yet expired.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER idle(0), scheduled(1)  

sdbDevOutSwUnlock 1.3.6.1.4.1.31034.12.1.1.2.7.3.1.4
Switching and rebooting is unlocked for 10 seconds by writing a 1.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER locked(0), unlocked(1)  

sdbDevOutSwIndividualOutletDelay 1.3.6.1.4.1.31034.12.1.1.2.7.3.1.5
Delay before an individual outlet switches on at power-up.
Status: current Access: read-write
OBJECT-TYPE    
  Second 0..65535  

sdbDevOutSwReboot 1.3.6.1.4.1.31034.12.1.1.2.7.3.1.6
Reboot outlet relay if current state is on and outlet is unlocked; The outlet will be turned on after 10 seconds.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER idle(0), reboot(1)  

sdbDevMeasuresTable 1.3.6.1.4.1.31034.12.1.1.2.8.1
A table containing information of temperatures of devices connected to the databus.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SdbDevMeasuresEntry

sdbDevMeasuresEntry 1.3.6.1.4.1.31034.12.1.1.2.8.1.1
Device measures entry containing temperature information objects of a particular databus device.
Status: current Access: not-accessible
OBJECT-TYPE    
  SdbDevMeasuresEntry  

sdbDevMsIntTemperature 1.3.6.1.4.1.31034.12.1.1.2.8.1.1.1
Actual internal device temperature in deg C
Status: current Access: read-only
OBJECT-TYPE    
  DeciCelsius  

sdbDevMsExtTemperature 1.3.6.1.4.1.31034.12.1.1.2.8.1.1.2
Actual external device temperature sensor in deg C.
Status: current Access: read-only
OBJECT-TYPE    
  DeciCelsius  

sdbDevMsIntTemperaturePeak 1.3.6.1.4.1.31034.12.1.1.2.8.1.1.3
Peak internal device temperature since last reset of alerts.
Status: current Access: read-only
OBJECT-TYPE    
  DeciCelsius  

sdbDevMsExtTemperaturePeak 1.3.6.1.4.1.31034.12.1.1.2.8.1.1.4
Peak external device temperature since last reset of alerts.
Status: current Access: read-only
OBJECT-TYPE    
  DeciCelsius  

sdbDevSnsTable 1.3.6.1.4.1.31034.12.1.1.2.8.2
A table containing information of sensors of devices connected to the databus.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SdbDevSnsEntry

sdbDevSnsEntry 1.3.6.1.4.1.31034.12.1.1.2.8.2.1
Sensors entry containing objects of a sensor of a particular databus device. Note that this table has two indexes. sdbDevIdIndex to identify a particular device and sdbDevSnsIndex to identify a particular sensor of the device identified by sdbDevIdIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  SdbDevSnsEntry  

sdbDevSnsIndex 1.3.6.1.4.1.31034.12.1.1.2.8.2.1.1
A unique value for each sensor. Its value ranges between 1 and the value of sdbDevCfSensors.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..16  

sdbDevSnsType 1.3.6.1.4.1.31034.12.1.1.2.8.2.1.2
Type of connected sensor. T = Temperature (C) H = Humidity (%) I = dry switch contact
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1)  

sdbDevSnsValue 1.3.6.1.4.1.31034.12.1.1.2.8.2.1.3
Value of connected sensor
Status: current Access: read-only
OBJECT-TYPE    
  DeciValue 0..327680  

sdbDevSnsName 1.3.6.1.4.1.31034.12.1.1.2.8.2.1.4
User definable name for sensors.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..6)  

sdbDevSsDeviceStatusCodeChanged 1.3.6.1.4.1.31034.12.1.0.1
Device status code changed. OBJECTS { sdbDevSsDeviceStatusCode }
Status: current Access: read-write
NOTIFICATION-TYPE    

sdbDevSsTemperatureAlertDetected 1.3.6.1.4.1.31034.12.1.0.2
Temperature alert detected. Internal temperature alert: OBJECTS { sdbDevSsTemperatureAlert, sdbDevMsIntTemperature, sdbDevMsIntTemperaturePeak } External analog temperature alert: OBJECTS { sdbDevSsTemperatureAlert, sdbDevMsExtTemperature, sdbDevMsExtTemperaturePeak } External digital temperature alert: OBJECTS { sdbDevSsTemperatureAlert, sdbDevSnsValue }
Status: current Access: read-write
NOTIFICATION-TYPE    

sdbDevSsInputCurrentAlertDetected 1.3.6.1.4.1.31034.12.1.0.3
Input current alert detected. OBJECTS { sdbDevSsInputCurrentAlert, sdbDevInActualCurrent }
Status: current Access: read-write
NOTIFICATION-TYPE    

sdbDevSsOutletCurrentAlertDetected 1.3.6.1.4.1.31034.12.1.0.4
Outlet current alert detected. OBJECTS { sdbDevSsOutletCurrentAlert, sdbDevOutMtActualCurrent }
Status: current Access: read-write
NOTIFICATION-TYPE    

sdbDevSsInputVoltageAlertDetected 1.3.6.1.4.1.31034.12.1.0.5
Input voltage alert detected. OBJECTS { sdbDevSsInputVoltageAlert, sdbDevInActualVoltage }
Status: current Access: read-write
NOTIFICATION-TYPE    

sdbDevSsOutletCurrentDropAlertDetected 1.3.6.1.4.1.31034.12.1.0.6
Outlet current drop alert detected. OBJECTS { sdbDevSsOutletCurrentDropAlert, sdbDevOutMtActualCurrent }
Status: current Access: read-write
NOTIFICATION-TYPE    

sdbDevSsInputCurrentDropAlertDetected 1.3.6.1.4.1.31034.12.1.0.7
Input current drop alert detected. OBJECTS { sdbDevSsInputCurrentDropAlert, sdbDevInActualCurrent }
Status: current Access: read-write
NOTIFICATION-TYPE    

sdbDevSsSensorChangeAlertDetected 1.3.6.1.4.1.31034.12.1.0.8
Sensor channel change alert detected. OBJECTS { sdbDevSsSensorChangeAlert }
Status: current Access: read-write
NOTIFICATION-TYPE    

sdbMgmtStsRingStateChanged 1.3.6.1.4.1.31034.12.1.0.9
Ring state changed. Ring state changded to open: OBJECTS { sdbMgmtStsRingState, sdbMgmtStsRingBreachIndex } Ring state changded to closed: OBJECTS { sdbMgmtStsRingState }
Status: current Access: read-write
NOTIFICATION-TYPE    

sdbDevSsOutletVoltageDropAlertDetected 1.3.6.1.4.1.31034.12.1.0.10
Outlet voltage drop alert detected. OBJECTS { sdbDevSsOutletVoltageDropAlert, sdbDevOutMtActualVoltage }
Status: current Access: read-write
NOTIFICATION-TYPE    

sdbMIBCompliance 1.3.6.1.4.1.31034.12.1.2.1.1
The requirements for conformance to the SCHLEIFENBAUER-DATABUS-MIB.
Status: current Access: read-write
MODULE-COMPLIANCE    

sdbMIBNotificationGroup 1.3.6.1.4.1.31034.12.1.2.2.1
A collection of notifications.
Status: current Access: read-write
NOTIFICATION-GROUP    

sdbMIBDevIdGroup 1.3.6.1.4.1.31034.12.1.2.2.3
A collection of objects providing identification information about the device.
Status: current Access: read-write
OBJECT-GROUP    

sdbMIBDevCfGroup 1.3.6.1.4.1.31034.12.1.2.2.4
A collection of objects providing configuration information about the device.
Status: current Access: read-write
OBJECT-GROUP    

sdbMIBDevSsGroup 1.3.6.1.4.1.31034.12.1.2.2.5
A collection of objects providing status information about the device.
Status: current Access: read-write
OBJECT-GROUP    

sdbMIBDevRsGroup 1.3.6.1.4.1.31034.12.1.2.2.6
Groups resettable attributes op the device.
Status: current Access: read-write
OBJECT-GROUP    

sdbMIBDevStGroup 1.3.6.1.4.1.31034.12.1.2.2.7
A collection of objects providing the actual settings about the device.
Status: current Access: read-write
OBJECT-GROUP    

sdbMIBDevInGroup 1.3.6.1.4.1.31034.12.1.2.2.8
A collection of objects providing the actual input measurements of the device.
Status: current Access: read-write
OBJECT-GROUP    

sdbMIBDevOutGroup 1.3.6.1.4.1.31034.12.1.2.2.9
A collection of objects providing the actual outlet measurements of the device.
Status: current Access: read-write
OBJECT-GROUP    

sdbMIBDevOutMtGroup 1.3.6.1.4.1.31034.12.1.2.2.10
A collection of objects providing the actual outlet measurements of the device.
Status: current Access: read-write
OBJECT-GROUP    

sdbMIBDevOutSwGroup 1.3.6.1.4.1.31034.12.1.2.2.11
A collection of objects providing the actual outlet measurements of the device.
Status: current Access: read-write
OBJECT-GROUP    

sdbMIBDevSensorGroup 1.3.6.1.4.1.31034.12.1.2.2.12
A collection of objects providing the actual environmental measurements of the device.
Status: current Access: read-write
OBJECT-GROUP    

sdbMIBMgmtStatusGroup 1.3.6.1.4.1.31034.12.1.2.2.13
A collection of objects providing management status information about the databus.
Status: current Access: read-write
OBJECT-GROUP    

sdbMIBMgmtControlGroup 1.3.6.1.4.1.31034.12.1.2.2.14
A collection of objects providing management control information about the databus.
Status: current Access: read-write
OBJECT-GROUP