RTM-MIB
File:
RTM-MIB.mib (11356 bytes)
Imported modules
Imported symbols
Defined Types
TrapConfigEntry |
|
SEQUENCE |
|
|
|
|
managerIPaddress |
IpAddress |
|
|
managerPortNumber |
INTEGER |
|
|
managerRowStatus |
INTEGER |
|
|
readingTrapsFlag |
INTEGER |
|
|
nextTrapSeqNum |
INTEGER |
|
TrapUploadEntry |
|
SEQUENCE |
|
|
|
|
trapManagerIPaddress |
IpAddress |
|
|
trapSequenceNum |
INTEGER |
|
|
trapPduString |
DisplayString |
|
|
endOfQueueFlag |
INTEGER |
|
RecoverTrapEntry |
|
SEQUENCE |
|
|
|
|
recoverTrapSequenceNum |
INTEGER |
|
|
recoverTrapPduString |
OCTET STRING |
|
Defined Values
rtm |
1.3.6.1.4.1.351.120 |
OBJECT IDENTIFIER |
|
|
|
trapConfigTable |
1.3.6.1.4.1.351.120.1.1 |
The trap configuration table. This table
is used for registering SNMP managers with the system.
The system will send traps only to the registered
SNMP mangers. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
TrapConfigEntry |
|
trapConfigEntry |
1.3.6.1.4.1.351.120.1.1.1 |
An entry for each of the SNMP Manager registered.
Each SNMP Manager is identified by its IP Address
specified in managerIPAddress object. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
TrapConfigEntry |
|
|
managerIPaddress |
1.3.6.1.4.1.351.120.1.1.1.1 |
A unique index value representing the SNMP manager. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
IpAddress |
|
|
managerPortNumber |
1.3.6.1.4.1.351.120.1.1.1.2 |
The UDP Port number on which the manager
receives traps from a system. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
managerRowStatus |
1.3.6.1.4.1.351.120.1.1.1.3 |
This object is used for adding(registering) and
deleting(de-registering) SNMP managers in the system.
By setting this object to 'addRow' snmp manager will be
registered with the system.
By setting this object to 'delRow' snmp manager will be
registered with the system.
In some systems, the SNMP Manager will be de-registered
automatically by the agent (to allow other SNMP managers
to register), if manager is idle for long time(
This time is called aging interval time).
In order to avoid Managers being de-registered automatically
it is expected that the SNMP Managers keep sending
keep-alive requests(SNMP GET on this object)
to the system for predefined interval(Choosen by
SNMP Manager). The keep-alive requests need to be
sent few minutes before the aging interval expires.
The aging value of the Registered Managers are in the
order of minutes(system dependent or user configured).
The value supported for the aging value
is system dependent. The system might support
aging value per manager basis or per node basis
(applicable to all the registered managers).
|
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
addRow(1), delRow(2) |
|
readingTrapsFlag |
1.3.6.1.4.1.351.120.1.1.1.4 |
An entry for the state of the manager.
The value 'false' indicates that SNMP manager is not
in the middle of uploading traps(via trapUploadTable).
The value 'true' indicates that SNMP manager is in the
middle of uploading traps(via trapUploadTable).
When the value is 'true' the system will not send traps
to the corresponding manager identified by
managerIPAddress object. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
false(1), true(2) |
|
nextTrapSeqNum |
1.3.6.1.4.1.351.120.1.1.1.5 |
Set by the manager to indicate the first trap(identified
by this sequence number) it is interested in uploading.
The agent increments this value when readingTrapsFlag is
set to true(1) and SNMP Get is performed on trapUploadTable.
The trapUploadTable entries returned depends upon this
value. If there are no traps in the system with the
the sequence number, the agent will set the value for
this object to the head of FIFO(Saved traps)
and return an error response. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
managerNumOfValidEntries |
1.3.6.1.4.1.351.120.1.2 |
The number of entries in trapConfigTable. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..12 |
|
lastSequenceNumber |
1.3.6.1.4.1.351.120.1.3 |
The sequence number of the last trap generated by
the system. This object is used in each of the
RTM Compliant trap definitions. The manager can
figure out whether any trap is lost(missing) by comparing
the lastSequenceNumber values received in last 2 traps. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
trapUploadTable |
1.3.6.1.4.1.351.120.1.4 |
The trapUploadTable is used by the manager to retrieve
missing(lost) traps using robust trap mechanism.
The manager does a Get request on this table. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
TrapUploadEntry |
|
trapUploadEntry |
1.3.6.1.4.1.351.120.1.4.1 |
Manager does a Get request on the elements of this entry
to upload missing traps. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
TrapUploadEntry |
|
|
trapManagerIPaddress |
1.3.6.1.4.1.351.120.1.4.1.1 |
IP address of the manager used as an index to the table.
The value of this object must match with the value
in the managerIPaddress object. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
IpAddress |
|
|
trapSequenceNum |
1.3.6.1.4.1.351.120.1.4.1.2 |
The sequence number associated with the trap.
This sequence number has to match with the
value in lastSequenceNumber object embedded
in trapPduString. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
trapPduString |
1.3.6.1.4.1.351.120.1.4.1.3 |
Trap description string. This contains the Trap PDU
that is stored in the system. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
endOfQueueFlag |
1.3.6.1.4.1.351.120.1.4.1.4 |
Flag indicating the last trap saved in the
system's FIFO queue. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
false(1), true(2) |
|
recoverTrapTable |
1.3.6.1.4.1.351.120.1.5 |
A table containing information about the traps
sent from the system/switch. The total number of
traps stored in the switch is implementation
specific.
It is expected that systems supporting RTM Mechanism
save atleast least 500 traps , so that NMS
applications can recover the traps if they
determined it to be lost. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
RecoverTrapEntry |
|
recoverTrapEntry |
1.3.6.1.4.1.351.120.1.5.1 |
The entry for each of the traps stored in the switch. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
RecoverTrapEntry |
|
|
recoverTrapSequenceNum |
1.3.6.1.4.1.351.120.1.5.1.1 |
The sequence number associated with the trap.
The system tries to find a matching entry
in the list of traps stored.
If there is a match, an valid entry returned
with value for 'recoverTrapPduString' object. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..2147483647 |
|
recoverTrapPduString |
1.3.6.1.4.1.351.120.1.5.1.2 |
Trap description string. This contains the Trap PDU
that is stored in the system. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(0..512) |
|