RS-232-MIB

File: RS-232-MIB.mib (25286 bytes)

Imported modules

SNMPv2-SMI SNMPv2-CONF IF-MIB
RFC1213-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE Counter32
Integer32 MODULE-COMPLIANCE OBJECT-GROUP
InterfaceIndex transmission

Defined Types

Rs232PortEntry  
SEQUENCE    
  rs232PortIndex InterfaceIndex
  rs232PortType INTEGER
  rs232PortInSigNumber Integer32
  rs232PortOutSigNumber Integer32
  rs232PortInSpeed Integer32
  rs232PortOutSpeed Integer32
  rs232PortInFlowType INTEGER
  rs232PortOutFlowType INTEGER

Rs232AsyncPortEntry  
SEQUENCE    
  rs232AsyncPortIndex InterfaceIndex
  rs232AsyncPortBits INTEGER
  rs232AsyncPortStopBits INTEGER
  rs232AsyncPortParity INTEGER
  rs232AsyncPortAutobaud INTEGER
  rs232AsyncPortParityErrs Counter32
  rs232AsyncPortFramingErrs Counter32
  rs232AsyncPortOverrunErrs Counter32

Rs232SyncPortEntry  
SEQUENCE    
  rs232SyncPortIndex InterfaceIndex
  rs232SyncPortClockSource INTEGER
  rs232SyncPortFrameCheckErrs Counter32
  rs232SyncPortTransmitUnderrunErrs Counter32
  rs232SyncPortReceiveOverrunErrs Counter32
  rs232SyncPortInterruptedFrames Counter32
  rs232SyncPortAbortedFrames Counter32
  rs232SyncPortRole INTEGER
  rs232SyncPortEncoding INTEGER
  rs232SyncPortRTSControl INTEGER
  rs232SyncPortRTSCTSDelay Integer32
  rs232SyncPortMode INTEGER
  rs232SyncPortIdlePattern INTEGER
  rs232SyncPortMinFlags Integer32

Rs232InSigEntry  
SEQUENCE    
  rs232InSigPortIndex InterfaceIndex
  rs232InSigName INTEGER
  rs232InSigState INTEGER
  rs232InSigChanges Counter32

Rs232OutSigEntry  
SEQUENCE    
  rs232OutSigPortIndex InterfaceIndex
  rs232OutSigName INTEGER
  rs232OutSigState INTEGER
  rs232OutSigChanges Counter32

Defined Values

rs232 1.3.6.1.2.1.10.33
The MIB module for RS-232-like hardware devices.
MODULE-IDENTITY    

rs232Number 1.3.6.1.2.1.10.33.1
The number of ports (regardless of their current state) in the RS-232-like general port table.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

rs232PortTable 1.3.6.1.2.1.10.33.2
A list of port entries. The number of entries is given by the value of rs232Number.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Rs232PortEntry

rs232PortEntry 1.3.6.1.2.1.10.33.2.1
Status and parameter values for a port.
Status: current Access: not-accessible
OBJECT-TYPE    
  Rs232PortEntry  

rs232PortIndex 1.3.6.1.2.1.10.33.2.1.1
The value of ifIndex for the port. By convention and if possible, hardware port numbers map directly to external connectors. The value for each port must remain constant at least from one re-initialization of the network management agent to the next.
Status: current Access: read-only
OBJECT-TYPE    
  InterfaceIndex  

rs232PortType 1.3.6.1.2.1.10.33.2.1.2
The port's hardware type.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER other(1), rs232(2), rs422(3), rs423(4), v35(5), x21(6)  

rs232PortInSigNumber 1.3.6.1.2.1.10.33.2.1.3
The number of input signals for the port in the input signal table (rs232PortInSigTable). The table contains entries only for those signals the software can detect and that are useful to observe.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

rs232PortOutSigNumber 1.3.6.1.2.1.10.33.2.1.4
The number of output signals for the port in the output signal table (rs232PortOutSigTable). The table contains entries only for those signals the software can assert and that are useful to observe.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

rs232PortInSpeed 1.3.6.1.2.1.10.33.2.1.5
The port's input speed in bits per second. Note that non-standard values, such as 9612, are probably not allowed on most implementations.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

rs232PortOutSpeed 1.3.6.1.2.1.10.33.2.1.6
The port's output speed in bits per second. Note that non-standard values, such as 9612, are probably not allowed on most implementations.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

rs232PortInFlowType 1.3.6.1.2.1.10.33.2.1.7
The port's type of input flow control. 'none' indicates no flow control at this level. 'ctsRts' and 'dsrDtr' indicate use of the indicated hardware signals.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), ctsRts(2), dsrDtr(3)  

rs232PortOutFlowType 1.3.6.1.2.1.10.33.2.1.8
The port's type of output flow control. 'none' indicates no flow control at this level. 'ctsRts' and 'dsrDtr' indicate use of the indicated hardware signals.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), ctsRts(2), dsrDtr(3)  

rs232AsyncPortTable 1.3.6.1.2.1.10.33.3
A list of asynchronous port entries. Entries need not exist for synchronous ports.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Rs232AsyncPortEntry

rs232AsyncPortEntry 1.3.6.1.2.1.10.33.3.1
Status and parameter values for an asynchronous port.
Status: current Access: not-accessible
OBJECT-TYPE    
  Rs232AsyncPortEntry  

rs232AsyncPortIndex 1.3.6.1.2.1.10.33.3.1.1
A unique value for each port. Its value is the same as rs232PortIndex for the port.
Status: current Access: read-only
OBJECT-TYPE    
  InterfaceIndex  

rs232AsyncPortBits 1.3.6.1.2.1.10.33.3.1.2
The port's number of bits in a character.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 5..8  

rs232AsyncPortStopBits 1.3.6.1.2.1.10.33.3.1.3
The port's number of stop bits.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER one(1), two(2), oneAndHalf(3), dynamic(4)  

rs232AsyncPortParity 1.3.6.1.2.1.10.33.3.1.4
The port's sense of a character parity bit.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), odd(2), even(3), mark(4), space(5)  

rs232AsyncPortAutobaud 1.3.6.1.2.1.10.33.3.1.5
A control for the port's ability to automatically sense input speed. When rs232PortAutoBaud is 'enabled', a port may autobaud to values different from the set values for speed, parity, and character size. As a result a network management system may temporarily observe values different from what was previously set.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

rs232AsyncPortParityErrs 1.3.6.1.2.1.10.33.3.1.6
Total number of characters with a parity error, input from the port since system re-initialization and while the port state was 'up' or 'test'.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

rs232AsyncPortFramingErrs 1.3.6.1.2.1.10.33.3.1.7
Total number of characters with a framing error, input from the port since system re-initialization and while the port state was 'up' or 'test'.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

rs232AsyncPortOverrunErrs 1.3.6.1.2.1.10.33.3.1.8
Total number of characters with an overrun error, input from the port since system re-initialization and while the port state was 'up' or 'test'.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

rs232SyncPortTable 1.3.6.1.2.1.10.33.4
A list of asynchronous port entries. Entries need not exist for synchronous ports.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Rs232SyncPortEntry

rs232SyncPortEntry 1.3.6.1.2.1.10.33.4.1
Status and parameter values for a synchronous port.
Status: current Access: not-accessible
OBJECT-TYPE    
  Rs232SyncPortEntry  

rs232SyncPortIndex 1.3.6.1.2.1.10.33.4.1.1
A unique value for each port. Its value is the same as rs232PortIndex for the port.
Status: current Access: read-only
OBJECT-TYPE    
  InterfaceIndex  

rs232SyncPortClockSource 1.3.6.1.2.1.10.33.4.1.2
Source of the port's bit rate clock. 'split' means the transmit clock is internal and the receive clock is external.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER internal(1), external(2), split(3)  

rs232SyncPortFrameCheckErrs 1.3.6.1.2.1.10.33.4.1.3
Total number of frames with an invalid frame check sequence, input from the port since system re-initialization and while the port state was 'up' or 'test'.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

rs232SyncPortTransmitUnderrunErrs 1.3.6.1.2.1.10.33.4.1.4
Total number of frames that failed to be transmitted on the port since system re-initialization and while the port state was 'up' or 'test' because data was not available to the transmitter in time.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

rs232SyncPortReceiveOverrunErrs 1.3.6.1.2.1.10.33.4.1.5
Total number of frames that failed to be received on the port since system re-initialization and while the port state was 'up' or 'test' because the receiver did not accept the data in time.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

rs232SyncPortInterruptedFrames 1.3.6.1.2.1.10.33.4.1.6
Total number of frames that failed to be received or transmitted on the port due to loss of modem signals since system re-initialization and while the port state was 'up' or 'test'.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

rs232SyncPortAbortedFrames 1.3.6.1.2.1.10.33.4.1.7
Number of frames aborted on the port due to receiving an abort sequence since system re-initialization and while the port state was 'up' or 'test'.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

rs232SyncPortRole 1.3.6.1.2.1.10.33.4.1.8
The role the device is playing that is using this port. dte means the device is performing the role of data terminal equipment dce means the device is performing the role of data circuit-terminating equipment.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER dte(1), dce(2)  

rs232SyncPortEncoding 1.3.6.1.2.1.10.33.4.1.9
The bit stream encoding technique that is in effect for this port. nrz for Non-Return to Zero encoding nrzi for Non-Return to Zero Inverted encoding.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER nrz(1), nrzi(2)  

rs232SyncPortRTSControl 1.3.6.1.2.1.10.33.4.1.10
The method used to control the Request To Send (RTS) signal. controlled when the DTE is asserts RTS each time data needs to be transmitted and drops RTS at some point after data transmission begins. If rs232SyncPortRole is 'dte', the RTS is an output signal. The device will issue a RTS and wait for a CTS from the DCE before starting to transmit. If rs232SyncPortRole is 'dce', the RTS is an input signal. The device will issue a CTS only after having received RTS and waiting the rs232SyncPortRTSCTSDelay interval. constant when the DTE constantly asserts RTS.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER controlled(1), constant(2)  

rs232SyncPortRTSCTSDelay 1.3.6.1.2.1.10.33.4.1.11
The interval (in milliseconds) that the DCE must wait after it sees RTS asserted before asserting CTS. This object exists in support of older synchronous devices that cannot recognize CTS within a certain interval after it asserts RTS.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

rs232SyncPortMode 1.3.6.1.2.1.10.33.4.1.12
The mode of operation of the port with respect to the direction and simultaneity of data transfer. fdx when frames on the data link can be transmitted and received at the same time hdx when frames can either be received from the data link or transmitted onto the data link but not at the same time. simplex-receive when frames can only be received on this data link. simplex-send when frames can only be sent on this data link.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER fdx(1), hdx(2), simplex-receive(3), simplex-send(4)  

rs232SyncPortIdlePattern 1.3.6.1.2.1.10.33.4.1.13
The bit pattern used to indicate an idle line.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER mark(1), space(2)  

rs232SyncPortMinFlags 1.3.6.1.2.1.10.33.4.1.14
The minimum number of flag patterns this port needs in order to recognize the end of one frame and the start of the next. Plausible values are 1 and 2.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

rs232InSigTable 1.3.6.1.2.1.10.33.5
A list of port input control signal entries implemented and visible to the software on the port, and useful to monitor.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Rs232InSigEntry

rs232InSigEntry 1.3.6.1.2.1.10.33.5.1
Input control signal status for a hardware port.
Status: current Access: not-accessible
OBJECT-TYPE    
  Rs232InSigEntry  

rs232InSigPortIndex 1.3.6.1.2.1.10.33.5.1.1
The value of rs232PortIndex for the port to which this entry belongs.
Status: current Access: read-only
OBJECT-TYPE    
  InterfaceIndex  

rs232InSigName 1.3.6.1.2.1.10.33.5.1.2
Identification of a hardware signal, as follows: rts Request to Send cts Clear to Send dsr Data Set Ready dtr Data Terminal Ready ri Ring Indicator dcd Received Line Signal Detector sq Signal Quality Detector srs Data Signaling Rate Selector srts Secondary Request to Send scts Secondary Clear to Send sdcd Secondary Received Line Signal Detector
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER rts(1), cts(2), dsr(3), dtr(4), ri(5), dcd(6), sq(7), srs(8), srts(9), scts(10), sdcd(11)  

rs232InSigState 1.3.6.1.2.1.10.33.5.1.3
The current signal state.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(1), on(2), off(3)  

rs232InSigChanges 1.3.6.1.2.1.10.33.5.1.4
The number of times the signal has changed from 'on' to 'off' or from 'off' to 'on'.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

rs232OutSigTable 1.3.6.1.2.1.10.33.6
A list of port output control signal entries implemented and visible to the software on the port, and useful to monitor.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Rs232OutSigEntry

rs232OutSigEntry 1.3.6.1.2.1.10.33.6.1
Output control signal status for a hardware port.
Status: current Access: not-accessible
OBJECT-TYPE    
  Rs232OutSigEntry  

rs232OutSigPortIndex 1.3.6.1.2.1.10.33.6.1.1
The value of rs232PortIndex for the port to which this entry belongs.
Status: current Access: read-only
OBJECT-TYPE    
  InterfaceIndex  

rs232OutSigName 1.3.6.1.2.1.10.33.6.1.2
Identification of a hardware signal, as follows: rts Request to Send cts Clear to Send dsr Data Set Ready dtr Data Terminal Ready ri Ring Indicator dcd Received Line Signal Detector sq Signal Quality Detector srs Data Signaling Rate Selector srts Secondary Request to Send scts Secondary Clear to Send sdcd Secondary Received Line Signal Detector
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER rts(1), cts(2), dsr(3), dtr(4), ri(5), dcd(6), sq(7), srs(8), srts(9), scts(10), sdcd(11)  

rs232OutSigState 1.3.6.1.2.1.10.33.6.1.3
The current signal state.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(1), on(2), off(3)  

rs232OutSigChanges 1.3.6.1.2.1.10.33.6.1.4
The number of times the signal has changed from 'on' to 'off' or from 'off' to 'on'.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

rs232Conformance 1.3.6.1.2.1.10.33.7
OBJECT IDENTIFIER    

rs232Groups 1.3.6.1.2.1.10.33.7.1
OBJECT IDENTIFIER    

rs232Compliances 1.3.6.1.2.1.10.33.7.2
OBJECT IDENTIFIER    

rs232Compliance 1.3.6.1.2.1.10.33.7.2.1
The compliance statement for SNMPv2 entities which have RS-232-like hardware interfaces.
Status: current Access: read-only
MODULE-COMPLIANCE    

rs232Group 1.3.6.1.2.1.10.33.7.1.1
A collection of objects providing information applicable to all RS-232-like interfaces.
Status: current Access: read-only
OBJECT-GROUP    

rs232AsyncGroup 1.3.6.1.2.1.10.33.7.1.2
A collection of objects providing information applicable to asynchronous RS-232-like interfaces.
Status: current Access: read-only
OBJECT-GROUP    

rs232SyncGroup 1.3.6.1.2.1.10.33.7.1.3
A collection of objects providing information applicable to synchronous RS-232-like interfaces.
Status: current Access: read-only
OBJECT-GROUP    

rs232SyncSDLCGroup 1.3.6.1.2.1.10.33.7.1.4
A collection of objects providing information applicable to synchronous RS-232-like interfaces running SDLC.
Status: current Access: read-only
OBJECT-GROUP