REDLINE-AN50-MIB

File: REDLINE-AN50-MIB.mib (38313 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC-1215
REDLINE-AN50-PMP-V1-MIB

Imported symbols

IpAddress Counter TimeTicks
enterprises OBJECT-TYPE TRAP-TYPE
an50pmpLastModifiedCID an50pmpLastMissedSsMacAddress an50pmpLastRegisteredSsMacAddress

Defined Values

redline 1.3.6.1.4.1.10728
OBJECT IDENTIFIER    

redlineProducts 1.3.6.1.4.1.10728.1
OBJECT IDENTIFIER    

redlineMgmt 1.3.6.1.4.1.10728.2
OBJECT IDENTIFIER    

redlineAn50 1.3.6.1.4.1.10728.2.16
OBJECT IDENTIFIER    

an50General 1.3.6.1.4.1.10728.2.16.1
OBJECT IDENTIFIER    

an50Config 1.3.6.1.4.1.10728.2.16.2
OBJECT IDENTIFIER    

an50Pm 1.3.6.1.4.1.10728.2.16.3
OBJECT IDENTIFIER    

an50Trap 1.3.6.1.4.1.10728.2.16.4
OBJECT IDENTIFIER    

an50LinkPmp 1.3.6.1.4.1.10728.2.16.5
OBJECT IDENTIFIER    

an50GenUBR 1.3.6.1.4.1.10728.2.16.1.1
Indicates the system's current uncoded burst rate. With adaptive modulation enabled, this rate may change over time, depending on the prevailing propagation conditions.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  


an50GenFrequency 1.3.6.1.4.1.10728.2.16.1.3
The frequency which represents the operating channel of the link. The system can be configured to operate over 9 distinct channels.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

an50GenAllignmentMode 1.3.6.1.4.1.10728.2.16.1.4
Specifies if the antenna alignment is done with buzzer or voltage.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER voltage(1), buzzer(2)  

an50GenEncryptionEnabled 1.3.6.1.4.1.10728.2.16.1.5
Specifies if encryption is enabled or not.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

an50GenFlowControlEnabled 1.3.6.1.4.1.10728.2.16.1.6
This attribute specifies if flow control is enabled or not.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

an50GenHttpAccessEnabled 1.3.6.1.4.1.10728.2.16.1.7
This attribute specifies if Http Access is enabled or not.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

an50GenTelnetAccessEnabled 1.3.6.1.4.1.10728.2.16.1.8
This attribute specifies if Telnet Access is enabled or not.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

an50GenTelnetPort 1.3.6.1.4.1.10728.2.16.1.9
This attribute specifies the Telnet port number.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

an50GenOptionsKey 1.3.6.1.4.1.10728.2.16.1.10
This attribute specifies the Product Options Key.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

an50GenResetDevice 1.3.6.1.4.1.10728.2.16.1.11
reset(2) indicates to reset the AN50 terminal. donothing(1) indicates do not reset AN50 terminal.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER donothing(1), reset(2)  

an50GenFault 1.3.6.1.4.1.10728.2.16.1.12
The attribute specifies the Fault LED status of the terminal.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(1), on(2), unknown(3)  

an50GenTxPower 1.3.6.1.4.1.10728.2.16.1.13
This object specifies the actual Tx Power of the AN-50 Node in ?
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER -20..20  

an50GenRegisteredStations 1.3.6.1.4.1.10728.2.16.1.14
This object specifies the actual number of configured links.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

an50GenRegisteredConnections 1.3.6.1.4.1.10728.2.16.1.15
This object specifies the actual number of configured connections.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  


an50GenChannelAutoScan 1.3.6.1.4.1.10728.2.16.1.17
This object specifies the Auto-Scanning feature for the channel.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

an50GenIduType 1.3.6.1.4.1.10728.2.16.1.18
This object specifies the Indoor Unit Type.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

an50GenOduType 1.3.6.1.4.1.10728.2.16.1.19
This object specifies the Outdoor Unit Type.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

an50ConfigEther 1.3.6.1.4.1.10728.2.16.2.1
OBJECT IDENTIFIER    

an50EtherMacAddress 1.3.6.1.4.1.10728.2.16.2.1.1
This object specifies the Ethernet MAC address of the local terminal.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

an50EtherGateway 1.3.6.1.4.1.10728.2.16.2.1.2
The IP Gateway of the AN-50 This field is used to specify the IP address of the gateway which the AN-50 is communicating through the core network.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

an50EtherPortStatus 1.3.6.1.4.1.10728.2.16.2.1.3
The attribute specifies the status of the Ethernet Port of the AN50.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER down(1), up(2), unknown(3)  

an50EtherIP 1.3.6.1.4.1.10728.2.16.2.1.4
The IP address of the AN-50. The default address from the factory is 192.168.25.2. For the initial set-up, the terminal should not be connected to the Internet network, i.e. the host computer should be connected directly to the terminal Ethernet port, to avoid address conflicts with other devices in a public network. Once the IP address has been set, the terminal can be connected to the core network, where it can receive either static or dynamic addressing (DHCP) in future configuration updates.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

an50EtherMask 1.3.6.1.4.1.10728.2.16.2.1.5
The IP Subnet Mask of the AN-50. The value is typically set to 255.255.255.0 (Class C subnet), which prevents certain local devices from going out into the wireless network.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

an50Ether100 1.3.6.1.4.1.10728.2.16.2.1.6
This object specifies the 100 Mb/s Ethernet LED status of the AN50.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER s10Mbs(1), s100Mbs(2), unknown(3)  

an50EtherFd 1.3.6.1.4.1.10728.2.16.2.1.7
The object specifies the Ethernet FullDuplex LED status of the AN50.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER halfDuplex(1), fullDuplex(2), unknown(3)  

an50EtherMgmVidEn 1.3.6.1.4.1.10728.2.16.2.1.8
The attribute specifies the Ethernet Management Vlan Enabled Status of the AN50.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

an50EtherMgmVid 1.3.6.1.4.1.10728.2.16.2.1.9
The attribute specifies the Ethernet Management Vlan Id of the AN50.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4095  

an50EtherLben 1.3.6.1.4.1.10728.2.16.2.1.10
The attribute specifies the Link Backup Enable Status of the AN50.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

an50ConfigWireless 1.3.6.1.4.1.10728.2.16.2.2
OBJECT IDENTIFIER    

an50WrlsChannel 1.3.6.1.4.1.10728.2.16.2.2.1
specifies the operating channel of the system, within the 100 MHz available in the 5.8GHz UNII band. To avoid interference, two PTP links operating in the same physical location (co-located) or within close proximity (e.g. across the street) must be separated by at least one channel, i.e. the gap between channels should be 20 MHz or more (e.g. channels 1 and 3).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER chan1(1), chan1A(2), chan2(3), chan2A(4), chan3(5), chan3A(6), chan4(7), chan4A(8), chan5(9)  

an50WrlsTxPower 1.3.6.1.4.1.10728.2.16.2.2.2
The Tx Power of the AN-50 in dBm. Specifies the power level of the system, which is preset at the factory and should not be altered. In the event that this parameter needs to be changed, please contact the Redline support team.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER -20..20  

an50WrlsModReduction 1.3.6.1.4.1.10728.2.16.2.2.3
The Modulation Reduction Level of the AN-50. Applies when the Adaptive rate is disabled. Specifies how many levels the system must drop in modulation before beginning re-transmission to address packet errors. The value can be set from 1-7, with 2 being the typical value.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..7  

an50WrlsAdaptiveMod 1.3.6.1.4.1.10728.2.16.2.2.4
Setting this attribute to AdaptiveRate(2) sets the system to operate in adaptive modulation mode. It is recommended to keep the AN-50 in this mode so that the system can automatically adjust the modulation level to the highest possible data rate based on measured RF performance. The user can define the minimum desired modulation level by setting the Main rate parameter. If the system meets this data rate, then the Signal LED on the front panel will light continuously green. If packet errors exceed one out of a million, the system will automatically lower the modulation level to maintain the link. In this case, the LED will flash green. If errors continue when the system reaches the lowest modulation level, the LED will flash red to indicate a failed RF link. The user can also disable the dynamic modulation mode by disabling Adaptive Modulation. In this mode, the user is required to set the Burst Rate and the Modulation Reduction Level. It is recommended not to operate the system in manual mode, as this mode is intended primarily for field support. Note the Signal LED will light solid green when the packet error rate is less than 1 out of a million. When the errors exceed this limit, the LED will not illuminate, indicating the RF link has failed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notAdaptiveRate(1), adaptiveRate(2)  

an50WrlsUBR 1.3.6.1.4.1.10728.2.16.2.2.5
This object contains the desired net uncoded burst rate for the link. Set uncoded burst rate in steps (0=6Mb/s, 1=9Mb/s, 2=12Mb/s, 3=18Mb/s, 4=24Mb/s, 5=36Mb/s, 6=48Mb/s, 7=54Mbs).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..7  

an50WrlsMaster 1.3.6.1.4.1.10728.2.16.2.2.6
The object contains the configured mode of the AN50 terminal. 1 = PTP Slave, 2 = PTP Master, 3 = PMP Slave, 4 = PMP Master
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ptpSlave(1), ptpMaster(2), pmpSlave(3), pmpMaster(4)  

an50WrlsVersion 1.3.6.1.4.1.10728.2.16.2.2.7
Sets the version of the AN50 system software. The software can be remotely downloaded into the AN50. The system comprises sufficient memory to hold two independent software loads. The operator can specify which load to set as the active version.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER firstFlash(1), secondFlash(2)  

an50WrlsEncryptCode 1.3.6.1.4.1.10728.2.16.2.2.8
The object contains the Encryption Key used for the AN-50 terminal. Enter the MAC address of the remote terminal to enable over-the-air data encryption.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

an50WrlsCableAttenuation 1.3.6.1.4.1.10728.2.16.2.2.9
This object contains the Cable Attenuation for the AN-50 in dB.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

an50WrlsRfPortStatus 1.3.6.1.4.1.10728.2.16.2.2.10
The object specifies the status of the AN50s Wireless Port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER down(1), up(2), unknown(3)  

an50WrlsSaveConfig 1.3.6.1.4.1.10728.2.16.2.2.11
The object saves the entire config set of the AN50.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER donothing(1), saveConfig(2)  

an50WrlsActivateConfig 1.3.6.1.4.1.10728.2.16.2.2.12
The object activates the entire config set of the AN50.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER donothing(1), activeConfig(2)  

an50WrlsRadioEnable 1.3.6.1.4.1.10728.2.16.2.2.13
The object specifies whether radio transmission is enabled or disabled.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER txOff(1), txOn(2)  

an50WrlsRfStatusErrorCode 1.3.6.1.4.1.10728.2.16.2.2.14
The object specifies the Error Code for the RF Status.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

an50WrlsRfSignal 1.3.6.1.4.1.10728.2.16.2.2.15
The object specifies the Wireless Signal LED status.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(1), on(2), blinking(3)  

an50WrlsLLMode 1.3.6.1.4.1.10728.2.16.2.2.16
Link length set mode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER auto(1), manual(2)  

an50WrlsLMU 1.3.6.1.4.1.10728.2.16.2.2.17
This object specifies the Link measurements unit (mile / Km).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER mile(1), km(2)  

an50WrlsLL 1.3.6.1.4.1.10728.2.16.2.2.18
This object specifies the Link Length. See an50WrlsLMU object for units.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

an50ConfigScheduler 1.3.6.1.4.1.10728.2.16.2.2.19
OBJECT IDENTIFIER    

an50WrlsFrameSize 1.3.6.1.4.1.10728.2.16.2.2.19.1
This object specifies the size of wireless frame (DL+RTD+UL) in micro seconds.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

an50WrlsMinBlockSize 1.3.6.1.4.1.10728.2.16.2.2.19.2
This object specifies a minimum number of bytes comprising transmitted block.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

an50WrlsDownlinkSize 1.3.6.1.4.1.10728.2.16.2.2.19.3
This object specifies the size of downlink sub-frame in micro seconds.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

an50WrlsRoundTripDelay 1.3.6.1.4.1.10728.2.16.2.2.19.4
This object specifies the round trip delay in micro seconds.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

an50WrlsAdaptiveDLSize 1.3.6.1.4.1.10728.2.16.2.2.19.5
This object specifies if adaptive downlink size is enabled or disabled.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

an50WrlsExtSyncronize 1.3.6.1.4.1.10728.2.16.2.2.19.6
This object specifies if external synchronization is enabled or disabled.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

an50WrlsMaximumDistance 1.3.6.1.4.1.10728.2.16.2.2.19.7
This object specifies the maximum distance between base station and subscriber station in Km.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..100  

an50WrlsRegistrationPeriod 1.3.6.1.4.1.10728.2.16.2.2.19.8
This object specifies the number of frames between registration periods.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..100  

an50ConfigDefGroup 1.3.6.1.4.1.10728.2.16.2.2.20
OBJECT IDENTIFIER    

an50WrlsBroadcastDLCIR 1.3.6.1.4.1.10728.2.16.2.2.20.1
This object specifies the broadcast downlink commited rate in kb/s.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

an50WrlsBroadcastDLPIR 1.3.6.1.4.1.10728.2.16.2.2.20.2
This object specifies the broadcast downlink peak rate in kb/s.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

an50WrlsDFSAction 1.3.6.1.4.1.10728.2.16.2.2.21
This object specifies the action taken when another system is detected on the same frequency
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), txDisabled(2), changeFreq(3)  

an50WrlsAntennaGain 1.3.6.1.4.1.10728.2.16.2.2.22
Antenna Gain in dB.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

an50WrlsATPEnabled 1.3.6.1.4.1.10728.2.16.2.2.23
This object specifies if the Automatic Transmitted Power Control is enabled
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

an50ResetStatistics 1.3.6.1.4.1.10728.2.16.3.1
A value of reset(2) resets the performance statistics on the AN-50, a value of donothing(1) does nothing.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER donothing(1), reset(2)  

an50PmEther 1.3.6.1.4.1.10728.2.16.3.2
OBJECT IDENTIFIER    

an50PmEtherRxPackets 1.3.6.1.4.1.10728.2.16.3.2.1
This object counts the number of ethernet packets successfully received by the local system.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

an50PmEtherRxPacketsErr 1.3.6.1.4.1.10728.2.16.3.2.2
This object counts the number of ethernet packet errors received by the local system.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

an50PmEtherTxPackets 1.3.6.1.4.1.10728.2.16.3.2.3
This object counts the number of Ethernet packets transmitted by the local system.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

an50PmEtherTxPacketsErr 1.3.6.1.4.1.10728.2.16.3.2.4
This object counts the number of Ethernet error packets transmitted by the local system.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

an50PmEtherRxPacketsDisc 1.3.6.1.4.1.10728.2.16.3.2.5
This object counts the number of ethernet packets discarded by receiver.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

an50PmEtherTxPacketsDisc 1.3.6.1.4.1.10728.2.16.3.2.6
This object counts the number of ethernet packets discarded by transmitter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

an50PmWrls 1.3.6.1.4.1.10728.2.16.3.3
OBJECT IDENTIFIER    

an50PmWrlsRxSigMin 1.3.6.1.4.1.10728.2.16.3.3.1
This object indicates the minimum received signal strength measured since the last SNMP update.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

an50PmWrlsRxSigMean 1.3.6.1.4.1.10728.2.16.3.3.2
This object indicates the average received signal strength measured since the last SNMP update.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

an50PmWrlsRxSigMax 1.3.6.1.4.1.10728.2.16.3.3.3
This object indicates the maximum received signal strength measured since the last SNMP update
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

an50PmWrlsAvgSinAdr 1.3.6.1.4.1.10728.2.16.3.3.4
This object indicates the average signal to noise ratio measured since the last SNMP update. The ratio is based on the digital information provided from the output of the AtoD converter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

an50PmWrlsRxPackets 1.3.6.1.4.1.10728.2.16.3.3.5
This object indicates the number of packets received over the air from the remote terminal.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

an50PmWrlsRxPacketsRetx 1.3.6.1.4.1.10728.2.16.3.3.6
This object indicates the number of packets retransmitted over the air from the remoter terminal.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

an50PmWrlsRxPacketsDisc 1.3.6.1.4.1.10728.2.16.3.3.7
This object indicates the number of packets, originating from the remote terminal lost over the air due to degradation in the RF link.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

an50PmWrlsTxPackets 1.3.6.1.4.1.10728.2.16.3.3.8
This object indicates the number of wireless packets (including Ethernet frames and error correction bytes) transmitted over the air by the local terminal.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

an50PmWrlsTxPacketsRetx 1.3.6.1.4.1.10728.2.16.3.3.9
This object indicates the number of packets retransmitted over the air by the local terminal. The retransmission scheme is based on the Acknowledge/Request (ARQ) algorithm that detects when packets are lost and makes a request to the MAC scheduler to repeat transmission of the lost packets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

an50PmWrlsTxPacketsDisc 1.3.6.1.4.1.10728.2.16.3.3.10
This object indicates the total number of packets lost over the air due to degradation in the RF link.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

an50PmWrlsCalcDst 1.3.6.1.4.1.10728.2.16.3.3.11
This object contains the calculated link distance.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

an50Sw 1.3.6.1.4.1.10728.2.16.2.3
OBJECT IDENTIFIER    

an50SwServer 1.3.6.1.4.1.10728.2.16.2.3.1
The address of the TFTP server used for software upgrades. If the address of the TFTP server is unknown, return 0.0.0.0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

an50SwFilename 1.3.6.1.4.1.10728.2.16.2.3.2
The file name of the software image to be loaded into this device.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..32)  

an50SwAdminStatus 1.3.6.1.4.1.10728.2.16.2.3.3
If set to upgrade(2), the device will initiate a TFTP software image download using an50SwFilename. If the download process is interrupted by a reset or power failure, the device will load the previous image. If set to noUpgrade(1), the device will revert to the previous version of the software. At initial startup, this object has the default value of noUpgrade(1).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noUpgrade(1), upgrade(2)  

an50SwOperStatus 1.3.6.1.4.1.10728.2.16.2.3.4
This object shows the download status. inProgress(1) indicates that a TFTP download is underway completeSuccess(2) indicates that the last software upgrade was successful failed(3) indicates that the last attempted download failed, ordinarily due to TFTP timeout.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER inProgress(1), completeSuccess(2), failed(3), other(4)  

an50SwCurrentVers 1.3.6.1.4.1.10728.2.16.2.3.5
The software version currently operating in this device's flash. This object should be in the syntax used by the individual vendor to identify software versions. If it is not applicable, this MUST contain an empty string.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

an50SwOtherVers 1.3.6.1.4.1.10728.2.16.2.3.6
The software version in the secondary flash. This object should be in the syntax used by the individual vendor to identify software versions. If it is not applicable, this MUST contain an empty string.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

an50SysLastTrapTime 1.3.6.1.4.1.10728.2.16.4.1
The value of system.sysUpTime when the last trap was generated. If no traps have been generated since the last reset, this attribute has a value of 0. No trap is issued as a result of a change to this value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

an50TftpFailTrap 1
An event to report the failure of a Software Download.
TRAP-TYPE    

an50TftpSuccessTrap 2
An event to report the success of a Software Download.
TRAP-TYPE    

an50PswdChangeFailTrap 3
An event to report the failure of a password change.
TRAP-TYPE    

an50FirmwareConfigFailTrap 4
An event to report the failure of a firmware config.
TRAP-TYPE    

an50EepromCorruptedTrap 5
An event to report the corruption of the EEPROM.
TRAP-TYPE    

an50PowerSupplyFailureTrap 6
An event to report the power supply failure.
TRAP-TYPE    

an50SaveConfigTrap 7
An event to report the saving of configuration
TRAP-TYPE    

an50ModifiedIDTrap 8
An event to report the modification in the configuration of a CID
TRAP-TYPE    

an50pmpRegistrationMissed 9
An event to report the missing of the registration by a AN50 Subscriber to one BS.This trap is sent by the BS and contains the MAC address of the SS missing the registration
TRAP-TYPE    

an50pmpRegistrationSuccessful 10
An event to report the successful registration of an AN50 Subscriber to BS. This trap is sent by the BS and contains the MAC address of the newly registered SS
TRAP-TYPE    

an50DFSEvent 11
An event to report a dynamic frequency selection (DFS) event in AN50
TRAP-TYPE    

an50MaxCid 1.3.6.1.4.1.10728.2.16.5.1
The object contains the maximum number of CID for this equipment
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..1024  

an50LinkCurrentAvailId 1.3.6.1.4.1.10728.2.16.5.2
The current available ID in the Links table that is queried by NMS before creating a new row in Link Table
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER