REDLINE-AN50-MIB
File:
REDLINE-AN50-MIB.mib (38313 bytes)
Imported modules
Imported symbols
Defined Values
redline |
1.3.6.1.4.1.10728 |
OBJECT IDENTIFIER |
|
|
|
an50Config |
1.3.6.1.4.1.10728.2.16.2 |
OBJECT IDENTIFIER |
|
|
|
an50Pm |
1.3.6.1.4.1.10728.2.16.3 |
OBJECT IDENTIFIER |
|
|
|
an50Trap |
1.3.6.1.4.1.10728.2.16.4 |
OBJECT IDENTIFIER |
|
|
|
an50GenUBR |
1.3.6.1.4.1.10728.2.16.1.1 |
Indicates the system's current uncoded burst rate. With
adaptive modulation enabled, this rate may change over time,
depending on the prevailing propagation conditions. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
an50GenRFLink |
1.3.6.1.4.1.10728.2.16.1.2 |
connected(2) indicates the terminal is communicating
properly to the remote terminal.
notConnected(1) indicates there is no communication with
the remote terminal. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
notConnected(1), connected(2) |
|
an50GenFrequency |
1.3.6.1.4.1.10728.2.16.1.3 |
The frequency which represents the operating channel of the link.
The system can be configured to operate over 9 distinct channels. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
an50GenAllignmentMode |
1.3.6.1.4.1.10728.2.16.1.4 |
Specifies if the antenna alignment is done with buzzer or voltage. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
voltage(1), buzzer(2) |
|
an50GenEncryptionEnabled |
1.3.6.1.4.1.10728.2.16.1.5 |
Specifies if encryption is enabled or not. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
no(1), yes(2) |
|
an50GenFlowControlEnabled |
1.3.6.1.4.1.10728.2.16.1.6 |
This attribute specifies if flow control is enabled or not. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
no(1), yes(2) |
|
an50GenHttpAccessEnabled |
1.3.6.1.4.1.10728.2.16.1.7 |
This attribute specifies if Http Access is enabled or not. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
no(1), yes(2) |
|
an50GenTelnetAccessEnabled |
1.3.6.1.4.1.10728.2.16.1.8 |
This attribute specifies if Telnet Access is enabled or not. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
no(1), yes(2) |
|
an50GenTelnetPort |
1.3.6.1.4.1.10728.2.16.1.9 |
This attribute specifies the Telnet port number. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
an50GenOptionsKey |
1.3.6.1.4.1.10728.2.16.1.10 |
This attribute specifies the Product Options Key. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
an50GenResetDevice |
1.3.6.1.4.1.10728.2.16.1.11 |
reset(2) indicates to reset the AN50 terminal.
donothing(1) indicates do not reset AN50 terminal. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
donothing(1), reset(2) |
|
an50GenFault |
1.3.6.1.4.1.10728.2.16.1.12 |
The attribute specifies the Fault LED status of the terminal. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
off(1), on(2), unknown(3) |
|
an50GenTxPower |
1.3.6.1.4.1.10728.2.16.1.13 |
This object specifies the actual Tx Power of the AN-50 Node in ? |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
-20..20 |
|
an50GenRegisteredStations |
1.3.6.1.4.1.10728.2.16.1.14 |
This object specifies the actual number of configured links. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
an50GenRegisteredConnections |
1.3.6.1.4.1.10728.2.16.1.15 |
This object specifies the actual number of configured connections. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
an50GenActiveWirelessLinks |
1.3.6.1.4.1.10728.2.16.1.16 |
This object specifies the actual number of provisioned links. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
an50GenChannelAutoScan |
1.3.6.1.4.1.10728.2.16.1.17 |
This object specifies the Auto-Scanning feature for the channel. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
no(1), yes(2) |
|
an50GenIduType |
1.3.6.1.4.1.10728.2.16.1.18 |
This object specifies the Indoor Unit Type. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
an50GenOduType |
1.3.6.1.4.1.10728.2.16.1.19 |
This object specifies the Outdoor Unit Type. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
an50EtherMacAddress |
1.3.6.1.4.1.10728.2.16.2.1.1 |
This object specifies the Ethernet MAC address of the local terminal. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
an50EtherGateway |
1.3.6.1.4.1.10728.2.16.2.1.2 |
The IP Gateway of the AN-50 This field is used to specify
the IP address of the gateway which
the AN-50 is communicating through the core network. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
IpAddress |
|
|
an50EtherPortStatus |
1.3.6.1.4.1.10728.2.16.2.1.3 |
The attribute specifies the status of the Ethernet Port of the AN50. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
down(1), up(2), unknown(3) |
|
an50EtherIP |
1.3.6.1.4.1.10728.2.16.2.1.4 |
The IP address of the AN-50. The default address from the factory
is 192.168.25.2. For the initial set-up, the terminal should not
be connected to the Internet network, i.e. the host computer should
be connected directly to the terminal Ethernet port, to avoid address
conflicts with other devices in a public network. Once the IP address
has been set, the terminal can be connected to the core network,
where it can receive either static or dynamic addressing (DHCP)
in future configuration updates. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
IpAddress |
|
|
an50EtherMask |
1.3.6.1.4.1.10728.2.16.2.1.5 |
The IP Subnet Mask of the AN-50. The value is typically set
to 255.255.255.0 (Class C subnet), which prevents certain
local devices from going out into the wireless network. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
IpAddress |
|
|
an50Ether100 |
1.3.6.1.4.1.10728.2.16.2.1.6 |
This object specifies the 100 Mb/s Ethernet LED status of the AN50. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
s10Mbs(1), s100Mbs(2), unknown(3) |
|
an50EtherFd |
1.3.6.1.4.1.10728.2.16.2.1.7 |
The object specifies the Ethernet FullDuplex LED status of the AN50. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
halfDuplex(1), fullDuplex(2), unknown(3) |
|
an50EtherMgmVidEn |
1.3.6.1.4.1.10728.2.16.2.1.8 |
The attribute specifies the Ethernet Management Vlan Enabled Status of the AN50. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
no(1), yes(2) |
|
an50EtherMgmVid |
1.3.6.1.4.1.10728.2.16.2.1.9 |
The attribute specifies the Ethernet Management Vlan Id of the AN50. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..4095 |
|
an50EtherLben |
1.3.6.1.4.1.10728.2.16.2.1.10 |
The attribute specifies the Link Backup Enable Status of the AN50. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
no(1), yes(2) |
|
an50WrlsChannel |
1.3.6.1.4.1.10728.2.16.2.2.1 |
specifies the operating channel of the system,
within the 100 MHz available in the 5.8GHz UNII band.
To avoid interference, two PTP links operating in
the same physical location (co-located) or within close
proximity (e.g. across the street) must be separated by at
least one channel, i.e. the gap between channels should
be 20 MHz or more (e.g. channels 1 and 3). |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
chan1(1), chan1A(2), chan2(3), chan2A(4), chan3(5), chan3A(6), chan4(7), chan4A(8), chan5(9) |
|
an50WrlsTxPower |
1.3.6.1.4.1.10728.2.16.2.2.2 |
The Tx Power of the AN-50 in dBm. Specifies the power level of the system,
which is preset at the factory and should not be altered. In the event
that this parameter needs to be changed, please contact the
Redline support team. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
-20..20 |
|
an50WrlsModReduction |
1.3.6.1.4.1.10728.2.16.2.2.3 |
The Modulation Reduction Level of the AN-50. Applies when the
Adaptive rate is disabled. Specifies how many levels the system
must drop in modulation before beginning re-transmission to address
packet errors.
The value can be set from 1-7, with 2 being the typical value. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..7 |
|
an50WrlsAdaptiveMod |
1.3.6.1.4.1.10728.2.16.2.2.4 |
Setting this attribute to AdaptiveRate(2) sets the system
to operate in adaptive modulation mode. It is recommended
to keep the AN-50 in this mode so that the system can
automatically adjust the modulation level to the highest possible
data rate based on measured RF performance. The user
can define the minimum desired modulation level by setting the
Main rate parameter.
If the system meets this data rate, then the Signal LED on the front
panel will light continuously green. If packet errors exceed
one out of a million, the system will automatically lower the modulation
level to maintain the link. In this case, the LED will flash green.
If errors continue when the system reaches the lowest modulation level,
the LED will flash red to indicate a failed RF link.
The user can also disable the dynamic modulation mode by disabling
Adaptive Modulation. In this mode, the user is required to set the
Burst Rate and the Modulation Reduction Level. It is recommended not
to operate the system in manual mode, as this mode is intended primarily
for field support.
Note the Signal LED will light solid green when the packet error rate is
less than 1 out of a million. When the errors exceed this limit, the LED
will not illuminate, indicating the RF link has failed. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
notAdaptiveRate(1), adaptiveRate(2) |
|
an50WrlsUBR |
1.3.6.1.4.1.10728.2.16.2.2.5 |
This object contains the desired net uncoded burst rate for the link.
Set uncoded burst rate in steps (0=6Mb/s, 1=9Mb/s, 2=12Mb/s,
3=18Mb/s, 4=24Mb/s, 5=36Mb/s, 6=48Mb/s, 7=54Mbs). |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..7 |
|
an50WrlsMaster |
1.3.6.1.4.1.10728.2.16.2.2.6 |
The object contains the configured mode of the AN50 terminal.
1 = PTP Slave, 2 = PTP Master, 3 = PMP Slave, 4 = PMP Master |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
ptpSlave(1), ptpMaster(2), pmpSlave(3), pmpMaster(4) |
|
an50WrlsVersion |
1.3.6.1.4.1.10728.2.16.2.2.7 |
Sets the version of the AN50 system software. The software
can be remotely downloaded into the AN50. The system
comprises sufficient memory to hold two independent software loads.
The operator can specify which load to set as the active version. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
firstFlash(1), secondFlash(2) |
|
an50WrlsEncryptCode |
1.3.6.1.4.1.10728.2.16.2.2.8 |
The object contains the Encryption Key used for the
AN-50 terminal. Enter the MAC address of the remote
terminal to enable over-the-air data encryption. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
an50WrlsCableAttenuation |
1.3.6.1.4.1.10728.2.16.2.2.9 |
This object contains the Cable Attenuation for the AN-50 in dB. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
an50WrlsRfPortStatus |
1.3.6.1.4.1.10728.2.16.2.2.10 |
The object specifies the status of the AN50s Wireless Port. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
down(1), up(2), unknown(3) |
|
an50WrlsSaveConfig |
1.3.6.1.4.1.10728.2.16.2.2.11 |
The object saves the entire config set of the AN50. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
donothing(1), saveConfig(2) |
|
an50WrlsActivateConfig |
1.3.6.1.4.1.10728.2.16.2.2.12 |
The object activates the entire config set of the AN50. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
donothing(1), activeConfig(2) |
|
an50WrlsRadioEnable |
1.3.6.1.4.1.10728.2.16.2.2.13 |
The object specifies whether radio transmission is enabled or disabled. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
txOff(1), txOn(2) |
|
an50WrlsRfStatusErrorCode |
1.3.6.1.4.1.10728.2.16.2.2.14 |
The object specifies the Error Code for the RF Status. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
an50WrlsRfSignal |
1.3.6.1.4.1.10728.2.16.2.2.15 |
The object specifies the Wireless Signal LED status. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
off(1), on(2), blinking(3) |
|
an50WrlsLLMode |
1.3.6.1.4.1.10728.2.16.2.2.16 |
Link length set mode. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
auto(1), manual(2) |
|
an50WrlsLMU |
1.3.6.1.4.1.10728.2.16.2.2.17 |
This object specifies the Link measurements unit (mile / Km). |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
mile(1), km(2) |
|
an50WrlsLL |
1.3.6.1.4.1.10728.2.16.2.2.18 |
This object specifies the Link Length.
See an50WrlsLMU object for units. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
an50WrlsFrameSize |
1.3.6.1.4.1.10728.2.16.2.2.19.1 |
This object specifies the size of wireless frame (DL+RTD+UL)
in micro seconds. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
an50WrlsMinBlockSize |
1.3.6.1.4.1.10728.2.16.2.2.19.2 |
This object specifies a minimum number of bytes comprising
transmitted block. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
an50WrlsDownlinkSize |
1.3.6.1.4.1.10728.2.16.2.2.19.3 |
This object specifies the size of downlink sub-frame in micro seconds. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
an50WrlsRoundTripDelay |
1.3.6.1.4.1.10728.2.16.2.2.19.4 |
This object specifies the round trip delay in micro seconds. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
an50WrlsAdaptiveDLSize |
1.3.6.1.4.1.10728.2.16.2.2.19.5 |
This object specifies if adaptive downlink size is
enabled or disabled. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
off(1), on(2) |
|
an50WrlsExtSyncronize |
1.3.6.1.4.1.10728.2.16.2.2.19.6 |
This object specifies if external synchronization is
enabled or disabled. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
off(1), on(2) |
|
an50WrlsMaximumDistance |
1.3.6.1.4.1.10728.2.16.2.2.19.7 |
This object specifies the maximum distance between
base station and subscriber station in Km. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..100 |
|
an50WrlsRegistrationPeriod |
1.3.6.1.4.1.10728.2.16.2.2.19.8 |
This object specifies the number of frames between registration periods. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..100 |
|
an50WrlsBroadcastDLCIR |
1.3.6.1.4.1.10728.2.16.2.2.20.1 |
This object specifies the broadcast downlink commited rate in kb/s. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
an50WrlsBroadcastDLPIR |
1.3.6.1.4.1.10728.2.16.2.2.20.2 |
This object specifies the broadcast downlink peak rate in kb/s. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
an50WrlsDFSAction |
1.3.6.1.4.1.10728.2.16.2.2.21 |
This object specifies the action taken when another system
is detected on the same frequency |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
none(1), txDisabled(2), changeFreq(3) |
|
an50WrlsAntennaGain |
1.3.6.1.4.1.10728.2.16.2.2.22 |
Antenna Gain in dB. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
an50WrlsATPEnabled |
1.3.6.1.4.1.10728.2.16.2.2.23 |
This object specifies if the Automatic Transmitted Power Control
is enabled |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
no(1), yes(2) |
|
an50ResetStatistics |
1.3.6.1.4.1.10728.2.16.3.1 |
A value of reset(2) resets the performance statistics on
the AN-50, a value of donothing(1) does nothing. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
donothing(1), reset(2) |
|
an50PmEther |
1.3.6.1.4.1.10728.2.16.3.2 |
OBJECT IDENTIFIER |
|
|
|
an50PmEtherRxPackets |
1.3.6.1.4.1.10728.2.16.3.2.1 |
This object counts the number of ethernet packets
successfully received by the local system. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
an50PmEtherRxPacketsErr |
1.3.6.1.4.1.10728.2.16.3.2.2 |
This object counts the number of ethernet packet errors
received by the local system. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
an50PmEtherTxPackets |
1.3.6.1.4.1.10728.2.16.3.2.3 |
This object counts the number of Ethernet packets
transmitted by the local system. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
an50PmEtherTxPacketsErr |
1.3.6.1.4.1.10728.2.16.3.2.4 |
This object counts the number of Ethernet error packets
transmitted by the local system. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
an50PmEtherRxPacketsDisc |
1.3.6.1.4.1.10728.2.16.3.2.5 |
This object counts the number of ethernet packets discarded
by receiver. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
an50PmEtherTxPacketsDisc |
1.3.6.1.4.1.10728.2.16.3.2.6 |
This object counts the number of ethernet packets discarded
by transmitter. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
an50PmWrls |
1.3.6.1.4.1.10728.2.16.3.3 |
OBJECT IDENTIFIER |
|
|
|
an50PmWrlsRxSigMin |
1.3.6.1.4.1.10728.2.16.3.3.1 |
This object indicates the minimum received signal strength
measured since the last SNMP update. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
an50PmWrlsRxSigMean |
1.3.6.1.4.1.10728.2.16.3.3.2 |
This object indicates the average received signal strength
measured since the last SNMP update. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
an50PmWrlsRxSigMax |
1.3.6.1.4.1.10728.2.16.3.3.3 |
This object indicates the maximum received signal strength
measured since the last SNMP update |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
an50PmWrlsAvgSinAdr |
1.3.6.1.4.1.10728.2.16.3.3.4 |
This object indicates the average signal to noise ratio measured
since the last SNMP update. The ratio is based on the
digital information provided from the output of the AtoD converter. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
an50PmWrlsRxPackets |
1.3.6.1.4.1.10728.2.16.3.3.5 |
This object indicates the number of packets received
over the air from the remote terminal. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
an50PmWrlsRxPacketsRetx |
1.3.6.1.4.1.10728.2.16.3.3.6 |
This object indicates the number of packets retransmitted
over the air from the remoter terminal. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
an50PmWrlsRxPacketsDisc |
1.3.6.1.4.1.10728.2.16.3.3.7 |
This object indicates the number of packets, originating from
the remote terminal lost over the air due to degradation in the RF link. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
an50PmWrlsTxPackets |
1.3.6.1.4.1.10728.2.16.3.3.8 |
This object indicates the number of wireless packets
(including Ethernet frames and error correction bytes)
transmitted over the air by the local terminal. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
an50PmWrlsTxPacketsRetx |
1.3.6.1.4.1.10728.2.16.3.3.9 |
This object indicates the number of packets retransmitted
over the air by the local terminal. The retransmission scheme
is based on the Acknowledge/Request (ARQ) algorithm that detects
when packets are lost and makes a request to the MAC scheduler
to repeat transmission of the lost packets. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
an50PmWrlsTxPacketsDisc |
1.3.6.1.4.1.10728.2.16.3.3.10 |
This object indicates the total number of packets lost
over the air due to degradation in the RF link. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
an50PmWrlsCalcDst |
1.3.6.1.4.1.10728.2.16.3.3.11 |
This object contains the calculated link distance. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
an50Sw |
1.3.6.1.4.1.10728.2.16.2.3 |
OBJECT IDENTIFIER |
|
|
|
an50SwServer |
1.3.6.1.4.1.10728.2.16.2.3.1 |
The address of the TFTP server used for software upgrades.
If the address of the TFTP server is unknown, return 0.0.0.0. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
IpAddress |
|
|
an50SwFilename |
1.3.6.1.4.1.10728.2.16.2.3.2 |
The file name of the software image to be loaded into this device. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(0..32) |
|
an50SwAdminStatus |
1.3.6.1.4.1.10728.2.16.2.3.3 |
If set to upgrade(2), the device will initiate a
TFTP software image download using an50SwFilename.
If the download process is interrupted by a reset or
power failure, the device will load the previous image.
If set to noUpgrade(1), the device will revert to the
previous version of the software.
At initial startup, this object has the default value of
noUpgrade(1). |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
noUpgrade(1), upgrade(2) |
|
an50SwOperStatus |
1.3.6.1.4.1.10728.2.16.2.3.4 |
This object shows the download status.
inProgress(1) indicates that a TFTP download is underway
completeSuccess(2) indicates that the last software upgrade
was successful
failed(3) indicates that the last attempted download
failed, ordinarily due to TFTP timeout. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
inProgress(1), completeSuccess(2), failed(3), other(4) |
|
an50SwCurrentVers |
1.3.6.1.4.1.10728.2.16.2.3.5 |
The software version currently operating in this device's flash.
This object should be in the syntax used by the individual
vendor to identify software versions. If it is not applicable,
this MUST contain an empty string. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
an50SwOtherVers |
1.3.6.1.4.1.10728.2.16.2.3.6 |
The software version in the secondary flash.
This object should be in the syntax used by the individual
vendor to identify software versions. If it is not
applicable, this MUST contain an empty string. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
an50SysLastTrapTime |
1.3.6.1.4.1.10728.2.16.4.1 |
The value of system.sysUpTime when the last trap was generated. If no traps
have been generated since the last reset, this attribute has a value of 0.
No trap is issued as a result of a change to this value. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
TimeTicks |
|
|
an50TftpFailTrap |
1 |
An event to report the failure of a Software Download. |
TRAP-TYPE |
|
|
|
an50ModifiedIDTrap |
8 |
An event to report the modification in the configuration of a CID |
TRAP-TYPE |
|
|
|
an50pmpRegistrationMissed |
9 |
An event to report the missing of the registration by a AN50
Subscriber to one BS.This trap is sent by the BS and contains
the MAC address of the SS missing the registration |
TRAP-TYPE |
|
|
|
an50pmpRegistrationSuccessful |
10 |
An event to report the successful registration of an AN50
Subscriber to BS. This trap is sent by the BS and contains
the MAC address of the newly registered SS |
TRAP-TYPE |
|
|
|
an50DFSEvent |
11 |
An event to report a dynamic frequency selection (DFS) event in AN50 |
TRAP-TYPE |
|
|
|
an50MaxCid |
1.3.6.1.4.1.10728.2.16.5.1 |
The object contains the maximum number of CID for this equipment |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
1..1024 |
|
an50LinkCurrentAvailId |
1.3.6.1.4.1.10728.2.16.5.2 |
The current available ID in the Links table that is queried by NMS before creating a new row in Link Table |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|