RADWIN-MIB-WINLINK1000

File: RADWIN-MIB-WINLINK1000.mib (134726 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC1213-MIB
RFC-1215

Imported symbols

enterprises IpAddress Counter
Gauge TimeTicks OBJECT-TYPE
DisplayString ifIndex TRAP-TYPE

Defined Types

Winlink1000OduAdmHostsEntry  
SEQUENCE    
  winlink1000OduAdmHostsIndex INTEGER
  winlink1000OduAdmHostsIp IpAddress
  winlink1000OduAdmHostsPort INTEGER
  winlink1000OduAdmHostsSecurityModel INTEGER
  winlink1000OduAdmHostsUserName DisplayString
  winlink1000OduAdmHostsPassword DisplayString
  winlink1000OduAdmHostsIPv6 DisplayString

Winlink1000OduSrvRingVlanIdEntry  
SEQUENCE    
  winlink1000OduSrvRingVlanIdIndex INTEGER
  winlink1000OduSrvRingVlanId INTEGER

Winlink1000OduSrvQoSConfEntry  
SEQUENCE    
  winlink1000OduSrvQoSConfIndex INTEGER
  winlink1000OduSrvConfVlanQGroups INTEGER
  winlink1000OduSrvConfDiffservQGroups INTEGER
  winlink1000OduSrvConfQueMir INTEGER
  winlink1000OduSrvConfQueWeight INTEGER

Winlink1000OduEthernetIfEntry  
SEQUENCE    
  winlink1000OduEthernetIfIndex INTEGER
  winlink1000OduEthernetIfAddress DisplayString
  winlink1000OduEthernetIfAdminStatus INTEGER
  winlink1000OduEthernetIfOperStatus INTEGER
  winlink1000OduEthernetIfFailAction INTEGER
  winlink1000OduEthernetIf1588v2PTPEventRXRate INTEGER
  winlink1000OduEthernetIf1588v2PTPEventTXRate INTEGER

Winlink1000OduBridgeBasePortEntry  
SEQUENCE    
  winlink1000OduBridgeBasePortIndex INTEGER
  winlink1000OduBridgeBaseIfIndex INTEGER

Winlink1000OduBridgeTpPortEntry  
SEQUENCE    
  winlink1000OduBridgeTpPortIndex INTEGER
  winlink1000OduBridgeTpPortInFrames Counter
  winlink1000OduBridgeTpPortOutFrames Counter
  winlink1000OduBridgeTpPortInBytes Counter
  winlink1000OduBridgeTpPortOutBytes Counter

Winlink1000OduAirChannelsEntry  
SEQUENCE    
  winlink1000OduAirChannelsIndex INTEGER
  winlink1000OduAirChannelsFrequency INTEGER
  winlink1000OduAirChannelsOperState INTEGER
  winlink1000OduAirChannelsAvail INTEGER
  winlink1000OduAirChannelsDefaultFreq INTEGER

Winlink1000OduAirMaxTxPowerEntry  
SEQUENCE    
  winlink1000OduAirMaxTxPowerIndex INTEGER
  winlink1000OduAirMaxTxPower INTEGER

Winlink1000OduAirChannelBWEntry  
SEQUENCE    
  winlink1000OduAirChannelBWIndex INTEGER
  winlink1000OduAirChannelBWAvail INTEGER
  winlink1000OduAirChannelsAdminState DisplayString
  winlink1000OduAirChannelBWHSSATDDConflictPerCBW INTEGER
  winlink1000OduAirChannelBWMinRatioForSupporting INTEGER
  winlink1000OduAirChannelBWMaxRatioForSupporting INTEGER

Winlink1000OduAirRatesEntry  
SEQUENCE    
  winlink1000OduAirRatesIndex INTEGER
  winlink1000OduAirRatesAvail INTEGER

Winlink1000OduAirHssRfpEntry  
SEQUENCE    
  winlink1000OduAirHssRfpIndex INTEGER
  winlink1000OduAirHssRfpEthChannelBW5MHz INTEGER
  winlink1000OduAirHssRfpTdmChannelBW5MHz INTEGER
  winlink1000OduAirHssRfpEthChannelBW10MHz INTEGER
  winlink1000OduAirHssRfpTdmChannelBW10MHz INTEGER
  winlink1000OduAirHssRfpEthChannelBW20MHz INTEGER
  winlink1000OduAirHssRfpTdmChannelBW20MHz INTEGER
  winlink1000OduAirHssRfpEthChannelBW40MHz INTEGER
  winlink1000OduAirHssRfpTdmChannelBW40MHz INTEGER
  winlink1000OduAirHssRfpEthChannelBW80MHz INTEGER
  winlink1000OduAirHssRfpEthChannelBW7MHz INTEGER
  winlink1000OduAirHssRfpEthChannelBW14MHz INTEGER

Winlink1000OduAirHssDiscoverEntry  
SEQUENCE    
  winlink1000OduAirHssDiscoverIndex INTEGER
  winlink1000OduAirHssDiscoverODUDescription DisplayString

Winlink1000OduAirHssAssociatedCUTableEntry  
SEQUENCE    
  winlink1000OduAirHssAssociatedCUIndex INTEGER
  winlink1000OduAirHssAssociatedCUDescription DisplayString

Defined Values

radwin 1.3.6.1.4.1.4458
OBJECT IDENTIFIER    

winlink1000 1.3.6.1.4.1.4458.1000
OBJECT IDENTIFIER    

winlink1000Odu 1.3.6.1.4.1.4458.1000.1
OBJECT IDENTIFIER    

winlink1000OduAdmin 1.3.6.1.4.1.4458.1000.1.1
OBJECT IDENTIFIER    

winlink1000OduAdmProductType 1.3.6.1.4.1.4458.1000.1.1.1
ODU configuration description.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

winlink1000OduAdmHwRev 1.3.6.1.4.1.4458.1000.1.1.2
ODU Hardware Version.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

winlink1000OduAdmSwRev 1.3.6.1.4.1.4458.1000.1.1.3
ODU Software Version.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

winlink1000OduAdmLinkName 1.3.6.1.4.1.4458.1000.1.1.4
Link Name. A change is effective immediately.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

winlink1000OduAdmResetCmd 1.3.6.1.4.1.4458.1000.1.1.5
Reset Command. A set command with a value of 3 will cause a device reset. HBS only: A set command with a value of 4 will cause a device reset for the entire sector. The read value is always 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

winlink1000OduAdmAddres 1.3.6.1.4.1.4458.1000.1.1.6
ODU IP address. A change is effective after reset. The parameter is kept for backward compatibility. Using the alternative parameter: winlink1000OduAdmIpParamsCnfg is recommended.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

winlink1000OduAdmMask 1.3.6.1.4.1.4458.1000.1.1.7
ODU Subnet Mask. A change is effective after reset. The parameter is kept for backward compatibility. Using the alternative parameter: winlink1000OduAdmIpParamsCnfg is recommended.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

winlink1000OduAdmGateway 1.3.6.1.4.1.4458.1000.1.1.8
ODU default gateway. A change is effective after reset. The parameter is kept for backward compatibility. Using the alternative parameter: winlink1000OduAdmIpParamsCnfg is recommended.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

winlink1000OduAdmBroadcast 1.3.6.1.4.1.4458.1000.1.1.10
This parameter is reserved for the Manager application provided with the product.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

winlink1000OduAdmHostsTable 1.3.6.1.4.1.4458.1000.1.1.12
Trap destinations table. Each trap destination is defined by an IP address and a UDP port. Up to 10 addresses can be configured.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Winlink1000OduAdmHostsEntry

winlink1000OduAdmHostsEntry 1.3.6.1.4.1.4458.1000.1.1.12.1
Trap destinations table entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Winlink1000OduAdmHostsEntry  

winlink1000OduAdmHostsIndex 1.3.6.1.4.1.4458.1000.1.1.12.1.1
Trap destinations table index.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

winlink1000OduAdmHostsIp 1.3.6.1.4.1.4458.1000.1.1.12.1.2
Trap destination IP address. A change is effective immediately.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

winlink1000OduAdmHostsPort 1.3.6.1.4.1.4458.1000.1.1.12.1.3
UDP port of the trap destination. A change is effective immediately.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

winlink1000OduAdmHostsSecurityModel 1.3.6.1.4.1.4458.1000.1.1.12.1.4
Security model used for this trap generation.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER snmpv1(1), snmpv3(3)  

winlink1000OduAdmHostsUserName 1.3.6.1.4.1.4458.1000.1.1.12.1.5
User name used to generate the snmpv3 trap.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

winlink1000OduAdmHostsPassword 1.3.6.1.4.1.4458.1000.1.1.12.1.6
Password used to generate the snmpv3 trap.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

winlink1000OduAdmHostsIPv6 1.3.6.1.4.1.4458.1000.1.1.12.1.7
Trap destination IPv6 address. A change is effective immediately.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

winlink1000OduBuzzerAdminState 1.3.6.1.4.1.4458.1000.1.1.13
This parameter controls the activation of the buzzer while the unit is in install mode. A change is effective immediately. The valid values are: disabled (0), enabledAuto (1), enabledConstantly(2), advancedAuto (3).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

winlink1000OduProductId 1.3.6.1.4.1.4458.1000.1.1.14
This parameter is reserved for the Manager application provided with the product.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

winlink1000OduReadCommunity 1.3.6.1.4.1.4458.1000.1.1.15
Read Community String. This parameter always returns ***** when retrieving its value. It is used by the Manager application to change the Read Community String. The SNMP agent accepts only encrypted values.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

winlink1000OduReadWriteCommunity 1.3.6.1.4.1.4458.1000.1.1.16
Read/Write Community String. This parameter always returns ***** when retrieving its value. It is used by the Manager application to change the Read/Write Community String. The SNMP agent accepts only encrypted values.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

winlink1000OduTrapCommunity 1.3.6.1.4.1.4458.1000.1.1.17
Trap Community String. This parameter is used by the Manager application to change the Trap Community String. The SNMP agent accepts only encrypted values.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

winlink1000OduAdmSnmpAgentVersion 1.3.6.1.4.1.4458.1000.1.1.18
Major version of the SNMP agent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

winlink1000OduAdmRemoteSiteName 1.3.6.1.4.1.4458.1000.1.1.19
Remote site name. Returns the same value as sysLocation parameter of the remote site.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

winlink1000OduAdmSnmpAgentMinorVersion 1.3.6.1.4.1.4458.1000.1.1.20
Minor version of the SNMP agent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

winlink1000OduAdmLinkPassword 1.3.6.1.4.1.4458.1000.1.1.21
Link Password. This parameter always returns ***** when retrieving its value. It is used by the Manager application to change the Link Password. The SNMP agent accepts only encrypted values.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

winlink1000OduAdmSiteLinkPassword 1.3.6.1.4.1.4458.1000.1.1.22
Site Link Password. This parameter always returns ***** when retrieving its value. It is used by the Manager application to change the Link Password of the site. The SNMP agent accepts only encrypted values.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

winlink1000OduAdmDefaultPassword 1.3.6.1.4.1.4458.1000.1.1.23
This parameter indicates if the current Link Password is the default password.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER default(1), nonDefault(2)  

winlink1000OduAdmConnectionType 1.3.6.1.4.1.4458.1000.1.1.24
This parameter indicates if the Manager application is connected to the local ODU or to the remote ODU over the air. A value of 'unknown' indicates community string mismatch.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER directConnection(1), indirectConnection(2), unknown(3)  

winlink1000OduAdmBackToFactorySettingsCmd 1.3.6.1.4.1.4458.1000.1.1.25
Back to factory settings Command. A change is effective after reset. The read value is always 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER withIP(1), withoutIP(2)  

winlink1000OduAdmIpParamsCnfg 1.3.6.1.4.1.4458.1000.1.1.26
ODU IP address Configuration. The format is: |||
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

winlink1000OduAdmVlanID 1.3.6.1.4.1.4458.1000.1.1.27
VLAN ID. Valid values are 1 to 4094. Initial value is 0 meaning VLAN unaware.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4094  

winlink1000OduAdmVlanPriority 1.3.6.1.4.1.4458.1000.1.1.28
VLAN Priority. 0 is lowest priority, 7 is highest priority.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..7  

winlink1000OduAdmSN 1.3.6.1.4.1.4458.1000.1.1.29
ODU Serial Number
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

winlink1000OduAdmProductName 1.3.6.1.4.1.4458.1000.1.1.30
This is the product name as it exists at EC
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

winlink1000OduAdmActivationKey 1.3.6.1.4.1.4458.1000.1.1.31
Activates a general key.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

winlink1000OduAdmRmtPermittedOduType 1.3.6.1.4.1.4458.1000.1.1.32
Mobile Application: permitted partner OduType.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

winlink1000OduAdmCpuID 1.3.6.1.4.1.4458.1000.1.1.33
CPU ID
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..64  

winlink1000OduAdmOvrdCmd 1.3.6.1.4.1.4458.1000.1.1.34
Ability to perform special command in the ODU.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

winlink1000OduAdmLinkMode 1.3.6.1.4.1.4458.1000.1.1.35
Unit PMP operation mode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER pmpHbs(1), pmpHsu(2), pmpHsuHyb(3), pmpHbsHyb(4)  

winlink1000OduAdmActualConnectMode 1.3.6.1.4.1.4458.1000.1.1.36
Unit connected as part to ptp or ptmp.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), ptp(2), ptmp(3)  

winlink1000OduAdmAES256Support 1.3.6.1.4.1.4458.1000.1.1.37
AES-256 security support indication.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notSupported(1), supported(2)  

winlink1000OduAdmAES256State 1.3.6.1.4.1.4458.1000.1.1.38
Enable/Disable AES-256 security mode over the air link.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

winlink1000OduAdmAES256Status 1.3.6.1.4.1.4458.1000.1.1.39
AES256 operating status
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notOperating(1), partiallyOperating(2), operating(3)  

winlink1000OduAdmBatterySavingShutdownTime 1.3.6.1.4.1.4458.1000.1.1.40
Battery Saving Shutdown Time in minutes, 0 till battery run out, -1 if not supported.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1000  

winlink1000OduAdmWiFiPowerMode 1.3.6.1.4.1.4458.1000.1.1.41
WIFI unit power mode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER undefined(1), powerON(2), powerOFF(3), alwaysON(4)  

winlink1000OduAdmShutdownTimer 1.3.6.1.4.1.4458.1000.1.1.42
Shutdown Timer in seconds.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..2147483647  

winlink1000OduAdmGPSState 1.3.6.1.4.1.4458.1000.1.1.43
GPS state
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER undefined(1), notSynchronized(2), fixed(3), shortCircuit(4), faulty(5), synchronized(6), synchronizedGlonass(7)  

winlink1000OduAdmTemperatureC 1.3.6.1.4.1.4458.1000.1.1.44
The temperature (Celsius) inside the Board.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

winlink1000OduAdmIPStackMode 1.3.6.1.4.1.4458.1000.1.1.45
The IP stack mode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER v4(1), v6(2), v4andv6(3)  

winlink1000OduAdmIPv6ParamsCnfg 1.3.6.1.4.1.4458.1000.1.1.46
ODU IPv6 address Configuration. The format is: |||
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

winlink1000OduAdmIPv6Address 1.3.6.1.4.1.4458.1000.1.1.47
ODU IPv6 address.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

winlink1000OduAdmIPv6Prefix 1.3.6.1.4.1.4458.1000.1.1.48
ODU IPv6 subnet mask.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

winlink1000OduAdmIPv6DefaultGateWay 1.3.6.1.4.1.4458.1000.1.1.49
ODU IPv6 default gateway.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

winlink1000OduAdmPowerConsumption 1.3.6.1.4.1.4458.1000.1.1.50
Power Consumption (mWatt)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

winlink1000OduAdmWifi 1.3.6.1.4.1.4458.1000.1.1.51
OBJECT IDENTIFIER    

winlink1000OduAdmWifiChannel 1.3.6.1.4.1.4458.1000.1.1.51.1
Wifi Channel
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..11  

winlink1000OduAdmWifiTxPower 1.3.6.1.4.1.4458.1000.1.1.51.2
Wifi TX Power
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 11..15  

winlink1000OduAdmWifiSSID 1.3.6.1.4.1.4458.1000.1.1.51.3
Wifi SSID
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

winlink1000OduAdmWifiSecurityType 1.3.6.1.4.1.4458.1000.1.1.51.4
Wifi Security type
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER open(1), wep(2), wpa2(3)  

winlink1000OduAdmWifiPassword 1.3.6.1.4.1.4458.1000.1.1.51.5
Wifi Password
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

winlink1000OduAdmWifiNetwork 1.3.6.1.4.1.4458.1000.1.1.51.6
Wifi Network
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

winlink1000OduAdmWifiRssi 1.3.6.1.4.1.4458.1000.1.1.51.7
Wifi RSSI
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

winlink1000OduAdmWifiStationMAC 1.3.6.1.4.1.4458.1000.1.1.51.8
Wifi Station MAC
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

winlink1000OduAdmWifiRestart 1.3.6.1.4.1.4458.1000.1.1.51.9
A set command with a value of 1 will cause a Wifi restart. The read value is always 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1  

winlink1000OduAdmWifiApStatus 1.3.6.1.4.1.4458.1000.1.1.51.10
Wifi AP Status
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(1), on(2), connected(3)  

winlink1000OduAdmBsaOperationMode 1.3.6.1.4.1.4458.1000.1.1.52
BSA Operation Mode
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER inactive(1), hbsTracking(2), hsuAlignment(3)  

winlink1000OduAdmMngConnection 1.3.6.1.4.1.4458.1000.1.1.53
Management Connection
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

winlink1000OduAdm1588TCSupport 1.3.6.1.4.1.4458.1000.1.1.54
Indicates that 1588TC license activated
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notSupported(1), supported(2)  

winlink1000OduAdmSyncESupport 1.3.6.1.4.1.4458.1000.1.1.55
ndicates that SyncE license activated
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notSupported(1), supported(2)  

winlink1000OduAdmRadioRev 1.3.6.1.4.1.4458.1000.1.1.56
Radio Revision
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

winlink1000OduAdmProductRev 1.3.6.1.4.1.4458.1000.1.1.57
Product Revision
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

winlink1000OduAdmPMPSUSupport 1.3.6.1.4.1.4458.1000.1.1.58
Indicates that PMP SU license is activated
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notSupported(1), supported(2)  

winlink1000OduAdmManagerDownloadURL 1.3.6.1.4.1.4458.1000.1.1.59
This is the URL from which management tool can be downloaded
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

winlink1000OduAdmAntennaDescription 1.3.6.1.4.1.4458.1000.1.1.60
The is a description of the antenna connected to the ODU
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

winlink1000OduAdmSwCapabilities 1.3.6.1.4.1.4458.1000.1.1.61
This is used to describe which Software Capabilities the current ODU supports
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

winlink1000OduService 1.3.6.1.4.1.4458.1000.1.2
OBJECT IDENTIFIER    

winlink1000OduSrvMode 1.3.6.1.4.1.4458.1000.1.2.1
System mode. The only values that can be set are installMode and slaveMode; normalMode reserved to the Manager application provided with the product. A change is effective after link re-synchronization.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER installMode(1), normalMode(2), slaveMode(3), tempInstallMode(4), inactiveMode(5)  

winlink1000OduSrvBridging 1.3.6.1.4.1.4458.1000.1.2.3
Bridging Mode. Valid values are: disabled (0), enabled (1).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

winlink1000OduServiceRingTopology 1.3.6.1.4.1.4458.1000.1.2.4
OBJECT IDENTIFIER    

winlink1000OduSrvRingLinkMode 1.3.6.1.4.1.4458.1000.1.2.4.1
Mode of the link regarding ring topology.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER independentLink(1), nonRpl(2), rpl(3)  

winlink1000OduSrvRingTopologySupported 1.3.6.1.4.1.4458.1000.1.2.4.2
Ring Topology, options are: supported, not supported
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notSupported(1), supported(2)  

winlink1000OduSrvRingVlanIdTable 1.3.6.1.4.1.4458.1000.1.2.4.3
Ring VLAN IDs table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Winlink1000OduSrvRingVlanIdEntry

winlink1000OduSrvRingVlanIdEntry 1.3.6.1.4.1.4458.1000.1.2.4.3.1
VLAN ID of the internal ring messages. Valid values are 1 to 4094. Initial value is 0 meaning VLAN unaware.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Winlink1000OduSrvRingVlanIdEntry  

winlink1000OduSrvRingVlanIdIndex 1.3.6.1.4.1.4458.1000.1.2.4.3.1.1
Index of VLAN ID of the internal ring messages.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..3  

winlink1000OduSrvRingVlanId 1.3.6.1.4.1.4458.1000.1.2.4.3.1.2
VLAN ID of the internal ring messages. Valid values are 1 to 4094. Initial value is 0 meaning VLAN unaware.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4094  

winlink1000OduSrvRingEthStatus 1.3.6.1.4.1.4458.1000.1.2.4.4
Represents the Ethernet service blocking state of a Rings link
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unblocked(1), blocked(2), notApplicable(3)  

winlink1000OduSrvRingMaxAllowedTimeFromLastRpm 1.3.6.1.4.1.4458.1000.1.2.4.5
Defines the minimal time (in ms) required for determination of ring failure.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

winlink1000OduSrvRingWTR 1.3.6.1.4.1.4458.1000.1.2.4.6
Defines the minimal time (in ms) required for ring recovery.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

winlink1000OduServiceQoS 1.3.6.1.4.1.4458.1000.1.2.5
OBJECT IDENTIFIER    

winlink1000OduSrvQoSMode 1.3.6.1.4.1.4458.1000.1.2.5.1
Mode of QoS feature.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notSupported(1), notActive(2), classVlan(3), classDiffserv(4)  

winlink1000OduSrvQoSConfTable 1.3.6.1.4.1.4458.1000.1.2.5.2
QoS configuration table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Winlink1000OduSrvQoSConfEntry

winlink1000OduSrvQoSConfEntry 1.3.6.1.4.1.4458.1000.1.2.5.2.1
QoS configuration table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Winlink1000OduSrvQoSConfEntry  

winlink1000OduSrvQoSConfIndex 1.3.6.1.4.1.4458.1000.1.2.5.2.1.1
Index of QoS Configuration.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..3  

winlink1000OduSrvConfVlanQGroups 1.3.6.1.4.1.4458.1000.1.2.5.2.1.2
Frames classification according to VLAN Priority IDs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..7  

winlink1000OduSrvConfDiffservQGroups 1.3.6.1.4.1.4458.1000.1.2.5.2.1.3
Frames classification according to Diffserv.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..48  

winlink1000OduSrvConfQueMir 1.3.6.1.4.1.4458.1000.1.2.5.2.1.4
Desired Private MIR.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

winlink1000OduSrvConfQueWeight 1.3.6.1.4.1.4458.1000.1.2.5.2.1.5
QoS queueu's weights in percent.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..100  

winlink1000OduSrvQoSVlanQGroupsSetStr 1.3.6.1.4.1.4458.1000.1.2.5.3
Frames classification according to VLAN IDs string for set.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

winlink1000OduSrvQoSDiffservQGroupsSetStr 1.3.6.1.4.1.4458.1000.1.2.5.4
Frames classification according to Diffserv IDs string for set.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

winlink1000OduSrvQoSMaxRTQuePercent 1.3.6.1.4.1.4458.1000.1.2.5.5
Maximal percent for RT & NRT queues.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

winlink1000OduServiceVlan 1.3.6.1.4.1.4458.1000.1.2.6
OBJECT IDENTIFIER    

winlink1000OduSrvVlanSupport 1.3.6.1.4.1.4458.1000.1.2.6.1
ODU Ethernet port VLAN support and configuration availability indication. 1 - ODU VLAN Functionality Not Supported 2 - ODU VLAN Functionality Supported 3 - ODU VLAN Functionality Supported and Available
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notSupported(1), supported(2), available(3)  

winlink1000OduSrvVlanIngressMode 1.3.6.1.4.1.4458.1000.1.2.6.2
ODU Ethernet port ingress VLAN mode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER transparent(1), untagAll(2), filter(3)  

winlink1000OduSrvVlanEgressMode 1.3.6.1.4.1.4458.1000.1.2.6.3
ODU Ethernet port egress VLAN mode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER transparent(1), tag(2), provider(3)  

winlink1000OduSrvEgressTag 1.3.6.1.4.1.4458.1000.1.2.6.4
ODU ethernet port egress VLAN tag. Right most digit is Vlan priority (0-7), other digits compose Vlan Id (2-4094)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..40947  

winlink1000OduSrvEgressProviderTag 1.3.6.1.4.1.4458.1000.1.2.6.5
ODU ethernet port egress Provider VLAN tag. Right most digit is Vlan priority (0-7), other digits compose Vlan Id (2-4094)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..40947  

winlink1000OduSrvVlanIngressAllowedVIDs 1.3.6.1.4.1.4458.1000.1.2.6.6
ODU ethernet port VLAN IDs that will not be filtered on ingress. w|w|w|w|w|w|w|w| ( where w = {0-4094} and w != 1 )
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

winlink1000OduSrvVlanDisable 1.3.6.1.4.1.4458.1000.1.2.6.7
Disable VLAN functionality. The following values can be set: 3 - Disable ODU & IDU VLAN Configurations.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

winlink1000OduServiceVlanProviderListTPIDstr 1.3.6.1.4.1.4458.1000.1.2.6.8
Holds the possible Provider TPIDs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

winlink1000OduEthernet 1.3.6.1.4.1.4458.1000.1.3
OBJECT IDENTIFIER    

winlink1000OduEthernetRemainingRate 1.3.6.1.4.1.4458.1000.1.3.1
Current Ethernet bandwidth in bps.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

winlink1000OduEthernetIfTable 1.3.6.1.4.1.4458.1000.1.3.2
ODU Ethernet Interface table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Winlink1000OduEthernetIfEntry

winlink1000OduEthernetIfEntry 1.3.6.1.4.1.4458.1000.1.3.2.1
ODU Ethernet Interface table entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Winlink1000OduEthernetIfEntry  

winlink1000OduEthernetIfIndex 1.3.6.1.4.1.4458.1000.1.3.2.1.1
ODU Ethernet Interface Index.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

winlink1000OduEthernetIfAddress 1.3.6.1.4.1.4458.1000.1.3.2.1.5
ODU MAC address.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

winlink1000OduEthernetIfAdminStatus 1.3.6.1.4.1.4458.1000.1.3.2.1.6
Required state of the interface.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER portAutoSense(1), portAutoSense100Mbps(5), forceHalfDuplex10Mbps(10), forceFullDuplex10Mbps(11), forceHalfDuplex100Mbps(15), forceFullDuplex100Mbps(16), forceFullDuplex1000Mbps(21), disablePoePort(254), disablePort(255)  

winlink1000OduEthernetIfOperStatus 1.3.6.1.4.1.4458.1000.1.3.2.1.7
Current operational state of the interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notConnected(1), connectedHalfDuplex10Mbps(10), connectedFullDuplex10Mbps(11), connectedHalfDuplex100Mbps(15), connectedFullDuplex100Mbps(16), connectedHalfDuplex1000Mbps(20), connectedFullDuplex1000Mbps(21), unknown(65535)  

winlink1000OduEthernetIfFailAction 1.3.6.1.4.1.4458.1000.1.3.2.1.8
Failure action of the interface.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER faNoAction(1), faForceHalfDuplex10Mbps(10), faForceFullDuplex10Mbps(11), faDisablePort(255)  

winlink1000OduEthernetIf1588v2PTPEventRXRate 1.3.6.1.4.1.4458.1000.1.3.2.1.9
For debug use
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

winlink1000OduEthernetIf1588v2PTPEventTXRate 1.3.6.1.4.1.4458.1000.1.3.2.1.10
For debug use
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

winlink1000OduEthernetNumOfPorts 1.3.6.1.4.1.4458.1000.1.3.3
Number of ODU network interfaces.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

winlink1000OduEthernetGbeSupported 1.3.6.1.4.1.4458.1000.1.3.4
Supported Giga bit Ethernet in ODU.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notSupported(1), supported(2)  

winlink1000OduEthernetSfpProperties 1.3.6.1.4.1.4458.1000.1.3.5
Sfp port properties.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

winlink1000OduBridge 1.3.6.1.4.1.4458.1000.1.4
OBJECT IDENTIFIER    

winlink1000OduBridgeBase 1.3.6.1.4.1.4458.1000.1.4.1
OBJECT IDENTIFIER    

winlink1000OduBridgeBasePortTable 1.3.6.1.4.1.4458.1000.1.4.1.4
ODU Bridge Ports table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Winlink1000OduBridgeBasePortEntry

winlink1000OduBridgeBasePortEntry 1.3.6.1.4.1.4458.1000.1.4.1.4.1
ODU Bridge Ports table entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Winlink1000OduBridgeBasePortEntry  

winlink1000OduBridgeBasePortIndex 1.3.6.1.4.1.4458.1000.1.4.1.4.1.1
ODU Bridge Port Number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

winlink1000OduBridgeBaseIfIndex 1.3.6.1.4.1.4458.1000.1.4.1.4.1.2
IfIndex corresponding to ODU Bridge port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

winlink1000OduBridgeTp 1.3.6.1.4.1.4458.1000.1.4.4
OBJECT IDENTIFIER    

winlink1000OduBridgeTpMode 1.3.6.1.4.1.4458.1000.1.4.4.101
ODU bridge mode. A change is effective after reset. Valid values: hubMode (0), bridgeMode (1).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

winlink1000OduBridgeTpPortTable 1.3.6.1.4.1.4458.1000.1.4.4.3
ODU Transparent Bridge Ports table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Winlink1000OduBridgeTpPortEntry

winlink1000OduBridgeTpPortEntry 1.3.6.1.4.1.4458.1000.1.4.4.3.1
ODU Transparent Bridge Ports table entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Winlink1000OduBridgeTpPortEntry  

winlink1000OduBridgeTpPortIndex 1.3.6.1.4.1.4458.1000.1.4.4.3.1.1
ODU Transparent Bridge Port Number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

winlink1000OduBridgeTpPortInFrames 1.3.6.1.4.1.4458.1000.1.4.4.3.1.3
Number of frames received by this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

winlink1000OduBridgeTpPortOutFrames 1.3.6.1.4.1.4458.1000.1.4.4.3.1.4
Number of frames transmitted by this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

winlink1000OduBridgeTpPortInBytes 1.3.6.1.4.1.4458.1000.1.4.4.3.1.101
Number of bytes received by this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

winlink1000OduBridgeTpPortOutBytes 1.3.6.1.4.1.4458.1000.1.4.4.3.1.102
Number of bytes transmitted by this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

winlink1000OduBridgeConfigMode 1.3.6.1.4.1.4458.1000.1.4.4.102
ODU bridge configuration mode
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

winlink1000OduAir 1.3.6.1.4.1.4458.1000.1.5
OBJECT IDENTIFIER    

winlink1000OduAirFreq 1.3.6.1.4.1.4458.1000.1.5.1
Installation Center Frequency. Valid values are product dependent. A change is effective after link re-synchronization.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

winlink1000OduAirDesiredRate 1.3.6.1.4.1.4458.1000.1.5.2
Deprecated parameter, actual behavior is read-only. Required Air Rate. For Channel Bandwidth of 20, 10, 5 MHz divide the value by 1, 2, 4 respectively.
Status: deprecated Access: read-write
OBJECT-TYPE    
  INTEGER  

winlink1000OduAirSSID 1.3.6.1.4.1.4458.1000.1.5.3
Reserved for the Manager application provided with the product. The Sector ID in Point-To-Multi-Point systems.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

winlink1000OduAirTxPower 1.3.6.1.4.1.4458.1000.1.5.4
Required Transmit power in dBm . This is a nominal value while the actual transmit power includes additional attenuation. The min and max values are product specific. A change is effective immediately.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

winlink1000OduAirSesState 1.3.6.1.4.1.4458.1000.1.5.5
Current Link State. The value is active (3) during normal operation.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER sessionDown(1), basicRate(2), active(3), installation(4), scanning(5), probing(6), transmitting(7), activeWithDefaultEncryptionKey(8), installationWithDefaultEncryptionKey(9), bitFailed(10), activeWithVersionsMismatch(11), installationWithVersionsMismatch(12), inactive(13), iduIncompatible(14), spectrumAnalysis(15)  

winlink1000OduAirMstrSlv 1.3.6.1.4.1.4458.1000.1.5.6
This parameter indicates if the device was automatically selected into the radio link master or slave. The value is undefined if there is no link. The value is relevant only for point to point systems.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

winlink1000OduAirResync 1.3.6.1.4.1.4458.1000.1.5.8
Setting this parameter to 1 will cause the link to restart the synchronization process.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

winlink1000OduAirPerf 1.3.6.1.4.1.4458.1000.1.5.9
OBJECT IDENTIFIER    

winlink1000OduAirRxPower 1.3.6.1.4.1.4458.1000.1.5.9.1
Received Signal Strength in dBm. Relevant only for point to point systems.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

winlink1000OduAirTotalFrames 1.3.6.1.4.1.4458.1000.1.5.9.2
Total number of radio frames.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

winlink1000OduAirBadFrames 1.3.6.1.4.1.4458.1000.1.5.9.3
Total number of received radio frames with CRC error. The value is relevant only for point to point systems .
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

winlink1000OduAirCurrentRate 1.3.6.1.4.1.4458.1000.1.5.9.4
Deprecated parameter. Actual rate of the air interface in Mbps. For Channel Bandwidth of 20, 10, 5 MHz divide the value by 1, 2, 4 respectively.
Status: deprecated Access: read-only
OBJECT-TYPE    
  INTEGER  

winlink1000OduAirCurrentRateIdx 1.3.6.1.4.1.4458.1000.1.5.9.5
Index of current air rate.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

winlink1000OduAirChainsRxPower 1.3.6.1.4.1.4458.1000.1.5.9.6
Received Signal Strength of Cpe chains in dBm. Chain 1 RSS: (1 Byte) Chain 2 RSS: (1 Byte) Chain 3 RSS: (1 Byte)
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

winlink1000OduAirCurrentRateCBW 1.3.6.1.4.1.4458.1000.1.5.9.7
CBW of current air rate.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

winlink1000OduAirCurrentRateGI 1.3.6.1.4.1.4458.1000.1.5.9.8
GI of current air rate.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

winlink1000OduAirTxPower36 1.3.6.1.4.1.4458.1000.1.5.10
Deprecated parameter. Actual behavior is read-only.
Status: deprecated Access: read-write
OBJECT-TYPE    
  INTEGER  

winlink1000OduAirTxPower48 1.3.6.1.4.1.4458.1000.1.5.11
Deprecated parameter. Actual behavior is read-only.
Status: deprecated Access: read-write
OBJECT-TYPE    
  INTEGER  

winlink1000OduAirCurrentTxPower 1.3.6.1.4.1.4458.1000.1.5.12
Current Transmit Power in dBm. This is a nominal value while the actual transmit power includes additional attenuation.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

winlink1000OduAirMinFrequency 1.3.6.1.4.1.4458.1000.1.5.13
Minimum center frequency in MHz.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

winlink1000OduAirMaxFrequency 1.3.6.1.4.1.4458.1000.1.5.14
Maximum center frequency in MHz.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

winlink1000OduAirFreqResolution 1.3.6.1.4.1.4458.1000.1.5.15
Center Frequency resolution. Measured in MHz if value < 100, otherwise in KHz.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

winlink1000OduAirCurrentFreq 1.3.6.1.4.1.4458.1000.1.5.16
Current Center Frequency. Measured in MHz if center frequency resolution value < 100, otherwise in KHz.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

winlink1000OduAirNumberOfChannels 1.3.6.1.4.1.4458.1000.1.5.17
Number of channels that can be used.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

winlink1000OduAirChannelsTable 1.3.6.1.4.1.4458.1000.1.5.18
Table of channels used by automatic channels selection (ACS).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Winlink1000OduAirChannelsEntry

winlink1000OduAirChannelsEntry 1.3.6.1.4.1.4458.1000.1.5.18.1
ACS channels table entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Winlink1000OduAirChannelsEntry  

winlink1000OduAirChannelsIndex 1.3.6.1.4.1.4458.1000.1.5.18.1.1
Channel Index.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

winlink1000OduAirChannelsFrequency 1.3.6.1.4.1.4458.1000.1.5.18.1.2
Channel frequency in MHz.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

winlink1000OduAirChannelsOperState 1.3.6.1.4.1.4458.1000.1.5.18.1.3
Channel state. Can be set by the user. Automatic Channel Selection uses channels that are AirChannelsOperState enabled and AirChannelsAvail enabled. A change is effective after link re-synchronization. Valid values: disabled (0), enabled (1). Rewriteable only in Point-To-Point products.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

winlink1000OduAirChannelsAvail 1.3.6.1.4.1.4458.1000.1.5.18.1.4
Channel state. Product specific and cannot be changed by the user. Automatic Channel Selection uses channels that are AirChannelsOperState enabled and AirChannelsAvail enabled. Valid values: disabled (0), enabled (1).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

winlink1000OduAirChannelsDefaultFreq 1.3.6.1.4.1.4458.1000.1.5.18.1.5
Default channel's availability for all CBWs. The valid values are: forbidden (0), available (1).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

winlink1000OduAirDfsState 1.3.6.1.4.1.4458.1000.1.5.19
Radar detection state. Valid values: disabled (0), enabled (1).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

winlink1000OduAirAutoChannelSelectionState 1.3.6.1.4.1.4458.1000.1.5.20
Deprecated parameter. Indicating Automatic Channel Selection availability at current channel bandwidth. Valid values: disabled (0), enabled (1).
Status: deprecated Access: read-only
OBJECT-TYPE    
  INTEGER  

winlink1000OduAirEnableTxPower 1.3.6.1.4.1.4458.1000.1.5.21
Indicating Transmit power configuration enabled or disabled.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

winlink1000OduAirMinTxPower 1.3.6.1.4.1.4458.1000.1.5.22
Minimum Transmit power in dBm.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

winlink1000OduAirMaxTxPowerTable 1.3.6.1.4.1.4458.1000.1.5.23
Table of Maximum transmit power per air rate, in dBm.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Winlink1000OduAirMaxTxPowerEntry

winlink1000OduAirMaxTxPowerEntry 1.3.6.1.4.1.4458.1000.1.5.23.1
Maximum Transmit power table entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Winlink1000OduAirMaxTxPowerEntry  

winlink1000OduAirMaxTxPowerIndex 1.3.6.1.4.1.4458.1000.1.5.23.1.1
Air interface rate index.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

winlink1000OduAirMaxTxPower 1.3.6.1.4.1.4458.1000.1.5.23.1.2
Maximum Transmit power in dBm.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

winlink1000OduAirChannelBandwidth 1.3.6.1.4.1.4458.1000.1.5.24
Channel bandwidth in KHz. A change is effective after reset.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

winlink1000OduAirChannelBWTable 1.3.6.1.4.1.4458.1000.1.5.25
Channel Bandwidths table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Winlink1000OduAirChannelBWEntry

winlink1000OduAirChannelBWEntry 1.3.6.1.4.1.4458.1000.1.5.25.1
Channel Bandwidth table entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Winlink1000OduAirChannelBWEntry  

winlink1000OduAirChannelBWIndex 1.3.6.1.4.1.4458.1000.1.5.25.1.1
Channel Bandwidth index.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER channelBW5MHz(1), channelBW10MHz(2), channelBW20MHz(3), channelBW40MHz(4), channelBW80MHz(5), channelBW7MHz(6), channelBW14MHz(7)  

winlink1000OduAirChannelBWAvail 1.3.6.1.4.1.4458.1000.1.5.25.1.2
Channel Bandwidth availability, product specific. Options are: Not supported, supported with manual channel selection, supported with Automatic Channel Selection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notSupported(1), supportedManual(2), supportedWithACS(3)  

winlink1000OduAirChannelsAdminState 1.3.6.1.4.1.4458.1000.1.5.25.1.3
Channels' availability per CBW.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

winlink1000OduAirChannelBWHSSATDDConflictPerCBW 1.3.6.1.4.1.4458.1000.1.5.25.1.4
Indication for possible Link drop per CBW due to conflict between HSS and ATDD.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noConflict(1), conflictSingle(2), conflictDual(3)  

winlink1000OduAirChannelBWMinRatioForSupporting 1.3.6.1.4.1.4458.1000.1.5.25.1.5
Minimal TX ratio that may be used by the HSM and still enable proper operation of the aforementioned CBW.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

winlink1000OduAirChannelBWMaxRatioForSupporting 1.3.6.1.4.1.4458.1000.1.5.25.1.6
Maximal TX ratio that may be used by the HSM and still enable proper operation of the aforementioned CBW.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

winlink1000OduAirRFD 1.3.6.1.4.1.4458.1000.1.5.26
Current radio frame duration in microseconds.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

winlink1000OduAirRatesTable 1.3.6.1.4.1.4458.1000.1.5.27
Air Rate indexes table for current channel bandwidth.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Winlink1000OduAirRatesEntry

winlink1000OduAirRatesEntry 1.3.6.1.4.1.4458.1000.1.5.27.1
Air Rate indexes table entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Winlink1000OduAirRatesEntry  

winlink1000OduAirRatesIndex 1.3.6.1.4.1.4458.1000.1.5.27.1.1
Air Rate index.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

winlink1000OduAirRatesAvail 1.3.6.1.4.1.4458.1000.1.5.27.1.2
Air Rate availability, depending on air interface conditions.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER rateNotAvailable(1), rateAvailable(2)  

winlink1000OduAirDesiredRateIdx 1.3.6.1.4.1.4458.1000.1.5.28
Required Air Rate index. 0 reserved for Adaptive Rate. A change is effective immediately after Set operation to the master side while the link is up.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

winlink1000OduAirLinkDistance 1.3.6.1.4.1.4458.1000.1.5.29
Link distance in meters. A value of -1 indicates an illegal value and is also used when a link is not established.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

winlink1000OduAirLinkWorkingMode 1.3.6.1.4.1.4458.1000.1.5.30
Link working mode as a result of comparing versions of both sides of the link. Possible modes are: Unknown - no link, Normal - versions on both sides are identical with full compatibility, with restricted compatibility, or versions on both sides are different with software upgrade or versions incompatibility.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), normal(2), fullCompatibilityRemoteUpgradeAvailable(3), fullCompatibilityLocalUpgradeAvailable(4), restrictedCompatibilityRemoteUpgradeRecomended(5), restrictedCompatibilityLocalUpgradeRecomended(6), softwareUpgradeRemoteUpgradeRequired(7), softwareUpgradeLocalUpgradeRequired(8), versionsIncompatibilityRemoteUpgradeRequired(9), versionsIncompatibilityLocalUpgradeRequired(10)  

winlink1000OduAirMajorLinkIfVersion 1.3.6.1.4.1.4458.1000.1.5.31
Major link interface version
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

winlink1000OduAirMinorLinkIfVersion 1.3.6.1.4.1.4458.1000.1.5.32
Minor link interface version
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

winlink1000OduAirHss 1.3.6.1.4.1.4458.1000.1.5.40
OBJECT IDENTIFIER    

winlink1000OduAirHssDesiredOpState 1.3.6.1.4.1.4458.1000.1.5.40.1
Required Hub Site Synchronization operating state. For HssSyncUnits : For hssISU :[2,7] ,For hssGSU :[2,6] For HBS: [2,3,4,5]
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notSupported(1), independentUnit(2), hubSyncMaster(3), hubSyncClientContinueTx(4), hubSyncClientDisableTx(5), gpsSync(6), independentSyncUnit-ISU(7)  

winlink1000OduAirHssCurrentOpState 1.3.6.1.4.1.4458.1000.1.5.40.2
Current Hub Site Synchronization operating state.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notSupported(1), independentUnit(2), hubSyncMaster(3), hubSyncClientContinueTx(4), hubSyncClientDisableTx(5), gpsSync(6), independentSyncUnit-ISU(7)  

winlink1000OduAirHssSyncStatus 1.3.6.1.4.1.4458.1000.1.5.40.3
Hub Site Synchronization sync status.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), notSynchronized(2), synchronized(3)  

winlink1000OduAirHssExtPulseStatus 1.3.6.1.4.1.4458.1000.1.5.40.4
Hub Site Synchronization external pulse detection status. In GSS mode: if generating then 1PSP is auto generated by the GSS Unit. if generatingAndDetecting then 1PSP is generated by GPS satellites signal.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notDetected(1), generating(2), generatingAndDetected(3), generatingAndImproperDetected(4), detected(5), improperDetected(6), multipleSourcesDetected(7)  

winlink1000OduAirHssExtPulseType 1.3.6.1.4.1.4458.1000.1.5.40.5
Hub Site Synchronization external pulse type.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), typeA(2), typeB(3), typeC(4), typeD(5), typeE(6), typeF(7)  

winlink1000OduAirHssDesiredExtPulseType 1.3.6.1.4.1.4458.1000.1.5.40.6
Hub Site Synchronization required external pulse type. Valid values for read write: {typeA(2),typeB(3),typeC(4),typeD(5),typeE(6),typeF(7)}. Valid value for read only: {notApplicable(1)}.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), typeA(2), typeB(3), typeC(4), typeD(5), typeE(6), typeF(7)  

winlink1000OduAirHssRfpTable 1.3.6.1.4.1.4458.1000.1.5.40.7
ODU Radio Frame Patterns (RFP) Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Winlink1000OduAirHssRfpEntry

winlink1000OduAirHssRfpEntry 1.3.6.1.4.1.4458.1000.1.5.40.7.1
ODU RFP Table entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Winlink1000OduAirHssRfpEntry  

winlink1000OduAirHssRfpIndex 1.3.6.1.4.1.4458.1000.1.5.40.7.1.1
ODU RFP Table index. The index represent the Radio Frame Pattern: typeA(2), typeB(3), typeC(4), typeD(5),typeE(6),typeF(7).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 2..7  

winlink1000OduAirHssRfpEthChannelBW5MHz 1.3.6.1.4.1.4458.1000.1.5.40.7.1.2
Represents the compatibility of Ethernet service under Channel BW of 5MHz in the specific Radio Frame Pattern.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER bestFit(1), nonOptimal(2), notAvailable(3)  

winlink1000OduAirHssRfpTdmChannelBW5MHz 1.3.6.1.4.1.4458.1000.1.5.40.7.1.3
Represents the compatibility of TDM service under Channel BW of 5MHz in the specific Radio Frame Pattern.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER bestFit(1), nonOptimal(2), notAvailable(3)  

winlink1000OduAirHssRfpEthChannelBW10MHz 1.3.6.1.4.1.4458.1000.1.5.40.7.1.4
Represents the compatibility of Ethernet service under Channel BW of 10MHz in the specific Radio Frame Pattern.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER bestFit(1), nonOptimal(2), notAvailable(3)  

winlink1000OduAirHssRfpTdmChannelBW10MHz 1.3.6.1.4.1.4458.1000.1.5.40.7.1.5
Represents the compatibility of TDM service under Channel BW of 10MHz in the specific Radio Frame Pattern.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER bestFit(1), nonOptimal(2), notAvailable(3)  

winlink1000OduAirHssRfpEthChannelBW20MHz 1.3.6.1.4.1.4458.1000.1.5.40.7.1.6
Represents the compatibility of Ethernet service under Channel BW of 20MHz in the specific Radio Frame Pattern.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER bestFit(1), nonOptimal(2), notAvailable(3)  

winlink1000OduAirHssRfpTdmChannelBW20MHz 1.3.6.1.4.1.4458.1000.1.5.40.7.1.7
Represents the compatibility of TDM service under Channel BW of 20MHz in the specific Radio Frame Pattern.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER bestFit(1), nonOptimal(2), notAvailable(3)  

winlink1000OduAirHssRfpEthChannelBW40MHz 1.3.6.1.4.1.4458.1000.1.5.40.7.1.8
Represents the compatibility of Ethernet service under Channel BW of 40MHz in the specific Radio Frame Pattern.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER bestFit(1), nonOptimal(2), notAvailable(3)  

winlink1000OduAirHssRfpTdmChannelBW40MHz 1.3.6.1.4.1.4458.1000.1.5.40.7.1.9
Represents the compatibility of TDM service under Channel BW of 40MHz in the specific Radio Frame Pattern.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER bestFit(1), nonOptimal(2), notAvailable(3)  

winlink1000OduAirHssRfpEthChannelBW80MHz 1.3.6.1.4.1.4458.1000.1.5.40.7.1.10
Represents the compatibility of Ethernet service under Channel BW of 80MHz in the specific Radio Frame Pattern.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER bestFit(1), nonOptimal(2), notAvailable(3)  

winlink1000OduAirHssRfpEthChannelBW7MHz 1.3.6.1.4.1.4458.1000.1.5.40.7.1.11
Represents the compatibility of Ethernet service under Channel BW of 7MHz in the specific Radio Frame Pattern.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER bestFit(1), nonOptimal(2), notAvailable(3)  

winlink1000OduAirHssRfpEthChannelBW14MHz 1.3.6.1.4.1.4458.1000.1.5.40.7.1.12
Represents the compatibility of Ethernet service under Channel BW of 14MHz in the specific Radio Frame Pattern.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER bestFit(1), nonOptimal(2), notAvailable(3)  

winlink1000OduAirHssRfpStr 1.3.6.1.4.1.4458.1000.1.5.40.8
Hub Site Synchronization supported patterns
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

winlink1000OduAirHssHsmID 1.3.6.1.4.1.4458.1000.1.5.40.9
A unique ID which is common to the HSM and all its collocated ODUs
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

winlink1000OduAirHssTime 1.3.6.1.4.1.4458.1000.1.5.40.10
Hub Site Synchronization GPS time
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

winlink1000OduAirHssLatitude 1.3.6.1.4.1.4458.1000.1.5.40.11
Hub Site Synchronization GPS Latitude
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

winlink1000OduAirHssNSIndicator 1.3.6.1.4.1.4458.1000.1.5.40.12
Hub Site Synchronization GPS N/S Indicator
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

winlink1000OduAirHssLongitude 1.3.6.1.4.1.4458.1000.1.5.40.13
Hub Site Synchronization GPS Longitude
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

winlink1000OduAirHssEWIndicator 1.3.6.1.4.1.4458.1000.1.5.40.14
Hub Site Synchronization GPS E/W Indicator
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

winlink1000OduAirHssNumSatellites 1.3.6.1.4.1.4458.1000.1.5.40.15
Hub Site Synchronization GPS Number of satellites
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

winlink1000OduAirHssAltitude 1.3.6.1.4.1.4458.1000.1.5.40.16
Hub Site Synchronization GPS Altitude
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

winlink1000OduAirHssRfpPhase 1.3.6.1.4.1.4458.1000.1.5.40.17
Hub Site Synchronization GPS RFP phase
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER rfpNormalPhase(1), rfpShiftedPhase(2)  

winlink1000OduAirHssInterSiteSynchronizationMode 1.3.6.1.4.1.4458.1000.1.5.40.18
Inter-Site Synchronization Mode - independent / synchronized
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER independent(1), synchronized(2)  

winlink1000OduAirHssInterSiteSynchronizationAvailability 1.3.6.1.4.1.4458.1000.1.5.40.19
Inter-Site Synchronization Availability
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notAvailable(1), available(2)  

winlink1000OduAirHssSatellitesSatSyncRequired 1.3.6.1.4.1.4458.1000.1.5.40.20
Satellites Synchronization Is Required
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notRequired(1), required(2)  

winlink1000OduAirHssDomainID 1.3.6.1.4.1.4458.1000.1.5.40.21
EHSS domain. Indentify set of CUs with same HSS synchronization
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

winlink1000OduAirHssSupportedSynchronizationProtocol 1.3.6.1.4.1.4458.1000.1.5.40.22
Supported Synchronization Protocols
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER serialOnly(1), ethOnly(2), both(3), ghssAndEth(4), ghssEthSerial(5)  

winlink1000OduAirHssDesiredSynchronizationProtocol 1.3.6.1.4.1.4458.1000.1.5.40.23
Desired Synchronization Protocols
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER serialOnly(1), ethOnly(2), both(3), ghssOnly(4)  

winlink1000OduAirHssDiscover 1.3.6.1.4.1.4458.1000.1.5.40.24
Initiate Discovery process of ODUs on the network.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER startAll(1), startAllMstr(2), startMyDmn(3), startMyMstr(4)  

winlink1000OduAirHssNumberOfDiscoveredODUs 1.3.6.1.4.1.4458.1000.1.5.40.25
Number OF Discovered ODUs in network.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1000  

winlink1000OduAirHssDiscoverTable 1.3.6.1.4.1.4458.1000.1.5.40.26
HSS Discover Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Winlink1000OduAirHssDiscoverEntry

winlink1000OduAirHssDiscoverEntry 1.3.6.1.4.1.4458.1000.1.5.40.26.1
ODU Discover Table entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Winlink1000OduAirHssDiscoverEntry  

winlink1000OduAirHssDiscoverIndex 1.3.6.1.4.1.4458.1000.1.5.40.26.1.1
HSS Discover Table Index.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..256  

winlink1000OduAirHssDiscoverODUDescription 1.3.6.1.4.1.4458.1000.1.5.40.26.1.2
Hold ODU HSS status in compress format: Domain,IP,HSS Role,Hss support, Enabled HSS protocol,Sync Status, Location, IPv6.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

winlink1000OduAirHssMasterSlaveCompatibility 1.3.6.1.4.1.4458.1000.1.5.40.27
EHSM version compatibility. Relevant to Ethernet HSS Clients only.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER compatible(1), notCompatible(2)  

winlink1000OduAirHssNumberOfAssociatedCU 1.3.6.1.4.1.4458.1000.1.5.40.28
Number of associated Ethernet HSS Clients. Relevant to Ethernet HSS Masters only
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..256  

winlink1000OduAirHssAssociatedCUTable 1.3.6.1.4.1.4458.1000.1.5.40.29
Associated Ethernet HSS Clients Table. Releant for Ethernet HSS Masters only.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Winlink1000OduAirHssAssociatedCUTableEntry

winlink1000OduAirHssAssociatedCUTableEntry 1.3.6.1.4.1.4458.1000.1.5.40.29.1
Associated Ethernet HSS Clients Table Entry. Releant for Ethernet HSS Masters only.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Winlink1000OduAirHssAssociatedCUTableEntry  

winlink1000OduAirHssAssociatedCUIndex 1.3.6.1.4.1.4458.1000.1.5.40.29.1.1
Associated Ethernet HSS Clients Table Index. Releant for Ethernet HSS Masters only.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..256  

winlink1000OduAirHssAssociatedCUDescription 1.3.6.1.4.1.4458.1000.1.5.40.29.1.2
Holds Associated Ethernet HSS Clients Description in compress format: IP,Delay,Compatibility,Ethernet Speed, Ethernet Rx rate, IPv6
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

winlink1000OduAirHssSyncStatusEth 1.3.6.1.4.1.4458.1000.1.5.40.30
Ethernet HSS Client Synchronization Level
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), notSynchronized(2), goodSynchronizationLevel(3), mediumSynchronizationLevel(4), badSynchronizationLevel(5), startSynchronization(6)  

winlink1000OduAirHssEthVLANTag 1.3.6.1.4.1.4458.1000.1.5.40.31
Ethernet HSS VLan Tag: The least significate decimal digit is the VLan Priority(0-6) and the rest of the digits represents VLan ID (2-4094)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..40947  

winlink1000OduAirHssHSMIPAddress 1.3.6.1.4.1.4458.1000.1.5.40.32
HSMs IP address. Relevant for HSC synchronized over Ethernet.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

winlink1000OduAirHssDelayToHSM 1.3.6.1.4.1.4458.1000.1.5.40.33
Delay in microseconds to HSM. Relevant for HSC synchronized over Ethernet.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1000000  

winlink1000OduAirHssSyncAcquisitionSeconds 1.3.6.1.4.1.4458.1000.1.5.40.34
Accumulated quantity of seconds in clock acquisition while connected to current HSM
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

winlink1000OduAirHssHSMIPv6Address 1.3.6.1.4.1.4458.1000.1.5.40.35
HSMs IPv6 address. Relevant for HSC synchronized over Ethernet.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

winlink1000OduAirLockRemote 1.3.6.1.4.1.4458.1000.1.5.41
This parameter enables locking the link with a specific ODU. The following values can be set: Unlock (default) - The ODU is not locked on a specific remote ODU. Unlock can only be performed when the link is not connected. Lock - The ODU is locked on a specific remote ODU. Lock can only be performed when the link is active.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unlock(1), lock(2)  

winlink1000OduAirAntennaGain  
Current Antenna Gain in 0.1 dBi resolution. User defined value for external antenna. Legal range: MinAntennaGain - Alarm.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

externalAlarmInPort2Alarm 106
The trap is sent every time an alarm occurs in the External Alarm Input of port #2. Contains a single parameter, which is its description: 1 - Description: External Alarm 2 - - Alarm.
TRAP-TYPE    

bitFailedAlarm 107
The trap is sent if there is no way to recover from the situation. Contains two parameters: 1 - Description: ODU power up built in test failed. Error code is: %n 2 - %n number
TRAP-TYPE    

wrongConfigurationLoadedAlarm 108
The trap is sent if there is a way to recover from the situation. Contains two parameters: 1 - Description: Wrong configuration loaded. Error code is: %n 2 - %n number
TRAP-TYPE    

lanPort1DisconnectedAlarm 109
Indicates the LAN port 1 status changed to disconnected. Contains a single parameter, which is its description: 1 - Description: LAN port 1 status changed to disconnected.
TRAP-TYPE    

lanPort2DisconnectedAlarm 110
Indicates the LAN port 2 status changed to disconnected. Contains a single parameter, which is its description: 1 - Description: LAN port 2 status changed to disconnected.
TRAP-TYPE    

mngPortDisconnectedAlarm 111
Indicates the LAN1 port status changed to disconnected. Contains a single parameter, which is its description: 1 - Description: LAN1 port status changed to disconnected.
TRAP-TYPE    

externalAlarmInPort3Alarm 112
The trap is sent every time an alarm occurs in the External Alarm Input of port #3. Contains a single parameter, which is its description: 1 - Description: External Alarm 3 - - Alarm.
TRAP-TYPE    

externalAlarmInPort4Alarm 113
The trap is sent every time an alarm occurs in the External Alarm Input of port #4. Contains a single parameter, which is its description: 1 - Description: External Alarm 4 - - Alarm.
TRAP-TYPE    

swVersionsMismatchFullCompatibilityAlarm 114
The trap is sent if SW versions mismatch with full link functionality. Contains a single parameter, which is its description: 1 - Description: Software versions mismatch - full link functionality
TRAP-TYPE    

swVersionsMismatchRestrictedCompatibilityAlarm 115
The trap is sent if SW versions mismatch with restricted link functionality. Contains a single parameter, which is its description: 1 - Description: Software versions mismatch - restricted link functionality
TRAP-TYPE    

swVersionsMismatchSoftwareUpgradeRequired 116
The trap is sent if SW versions mismatch and SW upgrade is required. Contains a single parameter, which is its description: 1 - Description: Software versions mismatch - Software upgrade required
TRAP-TYPE    

swVersionsIncompatible 117
The trap is sent if SW versions are incompatible. Contains a single parameter, which is its description: 1 - Description: SW Versions incompatible
TRAP-TYPE    

hssMultipleSourcesDetectedAlarm 118
Indicates that multiple sync pulse sources were detected. Contains a single parameter, which is its description: 1 - Description: HSS multiple sync sources were detected.
TRAP-TYPE    

hssSyncToProperSourceStoppedAlarm 119
Indicates that synchronization to a proper sync pulse source was stopped. Contains a single parameter, which is its description: 1 - Description: HSS sync pulse - Down. The reason is: %s. %s - Is the reason for the sync down.
TRAP-TYPE    

hssSyncPulseDetectedAlarm 120
Indicates that HSS additional sync pulse was detected. Contains a single parameter, which is its description: 1 - Description: HSS additional sync pulse was detected.
TRAP-TYPE    

tdmBackupAlarm 121
Indicates that the TDM backup link was activated. Contains a single parameter, which is its description: 1 - Description: TDM backup alarm - backup link was activated.
TRAP-TYPE    

linkLockUnauthorizedRemoteODU 122
Indicates that the remote ODU is unauthorized. Contains a single parameter, which is its description: 1 - Description: Unauthorized remote ODU connection rejected.
TRAP-TYPE    

linkLockUnauthorizedODU 123
Indicates that the ODU is unauthorized. Contains a single parameter, which is its description: 1 - Description: Unauthorized ODU connection rejected.
TRAP-TYPE    

hotStandbyAlarm 124
Indicates that the hot standby secondary link was activated. Contains a single parameter, which is its description: 1 - Description: Secondary Link Is Active.
TRAP-TYPE    

sfpInsertion 126
Indicates that a device was inserted to SFP Port
TRAP-TYPE    

sfpPort1DisconnectedAlarm 127
Indicates the SFP port 1 status changed to disconnected. Contains a single parameter which is its description: 1 - Description: SFP port 1 status changed to disconnected.
TRAP-TYPE    

ringRplStateActiveAlarm 128
RPL state changed to Active.
TRAP-TYPE    

desiredRatioCanNotBeAppliedAlarm 129
Indicates Desired UL/DL RAtio Can Not Be Applied.
TRAP-TYPE    

cbwMismatch 130
Indicates that a Channel Bandwidth mismatch was detected. Contains two parameters: 1 - Description: Channel Bandwidth Mismatch: one side is %n0 MHz and the other is %n1 MHz. %n0 is the local Channel Bandwidth value in MHz. %n1 is the remoet Channel Bandwidth value in MHz.
TRAP-TYPE    

gpsNotSynchronized 131
Indicates that the GPS is not synchronized with satellites. Pulses are self generated.
TRAP-TYPE    

pdTooHighDueCbwLimitations 132
Indicates that link cannot be established because link range is too large for channel bandwidth.
TRAP-TYPE    

hbsEncryptionAlarm 133
Indicates an encryption key mismatch. Contains a single parameter, which is its description, including the HSU's name
TRAP-TYPE    

hbsEhServiceClosedToHsu 134
Indicates an encryption key mismatch. Contains a single parameter, which is its description, including the HSU's name
TRAP-TYPE    

hbsUnsynchronizedHsuAlarm 135
Indicates a registered HSU lost synchronization.
TRAP-TYPE    

hbsInactiveHbsAlarm 136
Indicates HBS is InActive.
TRAP-TYPE    

incompatibleHsu 137
Indicates that the HSU is not compatible to HBS. Contains a single parameter, which is its description: 1 - Description: Incompatible ODUs.
TRAP-TYPE    

hsuUnsupportedBeacon 138
Indicates an unsupported beacon has arrived at HSU
TRAP-TYPE    

lanPortDisconnectedAlarm 139
Indicates the LAN port status changed to disconnected. Contains a single parameter, which is its description: 1 - Description: LAN port status changed to disconnected.
TRAP-TYPE    

poePortDisconnectedAlarm 140
Indicates the LAN2 port status changed to disconnected. Contains a single parameter, which is its description: 1 - Description: LAN2 port status changed to disconnected.
TRAP-TYPE    

poePowerConsumptionAlarm 141
Indicates the POE Power Consumption is above allowed maximum. Contains a single parameter, which is its description: 1 - Description: POE consumption above allowed maximum. port closed.
TRAP-TYPE    

hobupFaultyStateAlarm 149
This Alarm will indicate that the Hot Backup module is in faulty state. 1 - Description: Hot Backup fault detected: %s unit. %s - Primary Or Secondary Unit
TRAP-TYPE    

gpsOverCurrentAlarm 150
Indicates the GPS Antenna current consumption is above allowed maximum. Contains a single parameter, which is its description: 1 - Description: GPS Antenna current consumption above allowed maximum. GPS closed.
TRAP-TYPE    

gpsCommunicationFailiureAlarm 151
Indicates the GPS data isn't received. Contains a single parameter, which is its description: 1 - Description: GPS Communication failiure.
TRAP-TYPE    

temperatureThresholdAlarm 152
Indicates the board temperature is above allowed maximum. Contains a single parameter, which is its description: 1 - Description: GPS Antenna current consumption above allowed maximum. GPS closed.
TRAP-TYPE    

localRouterDiscoveryStatus 153
This Alarm will indicate that we have no connection with local train router. 1 - Description: MacLearningUpdate detected disconnection with local train router %s %s - local train IP
TRAP-TYPE    

trackRouterDiscoveryStatus 154
This Alarm will indicate that we have no connection with Track side router. 1 - Description: MacLearningUpdate detected disconnection with Track side router %s %s - Default gateway IP
TRAP-TYPE    

lastUserSnmpAccessOverHourAgo 155
This trap will indicate that the last access of the accessing user was more than an hour ago. 1 - Description: User %s performed SNMP access after more than an hour. %s - user name
TRAP-TYPE    

btsTargetUnreachable 156
This Alarm will indicate that we have no connection with Bts desired target. 1 - Description: TNC detected disconnection with the BTS target %s %s - Default gateway IP
TRAP-TYPE    

tdmServiceClear 200
Indicates that TDM Service fault is cleared. Contains a single parameter, which is its description: 1 - Description: TDM Service - Normal.
TRAP-TYPE    

ethServiceOpened 201
Indicates that Ethernet Service has been opened. Contains a single parameter, which is its description: 1 - Description: Ethernet Service has been opened.
TRAP-TYPE    

encryptionClear 203
Indicates that encryption is OK. Contains a single parameter, which is its description: 1 - Description: Encryption Status - Normal.
TRAP-TYPE    

changeLinkPasswordClear 204
Indicates that the Link Password was changed successfully. Contains a single parameter, which is its description: 1 - Description: Link Password has been changed at/on: %s. %s - Is the Local Site name or Remote Site name or both sides of the Link.
TRAP-TYPE    

externalAlarmInPort1Clear 205
This Trap is sent every time an External Alarm Input fault of port # 1 is cleared. Contains a single parameter, which is its description: 1 - Description: External Alarm 1 - - Alarm Cleared.
TRAP-TYPE    

externalAlarmInPort2Clear 206
This Trap is sent every time an External Alarm Input fault of port # 2 is cleared. Contains a single parameter, which is its description: 1 - Description: External Alarm 2 - - Alarm Cleared.
TRAP-TYPE    

lanPort1Clear 209
Indicates the LAN port 1 status changed to connected. Contains two parameters: 1 - Description: LAN port 1 status changed to connected - %s 2 - %s Is the Eth. mode (speed & duplex)
TRAP-TYPE    

lanPort2Clear 210
Indicates the LAN port 2 status changed to connected. Contains two parameters: 1 - Description: LAN port 2 status changed to connected - %s. 2 - %s Is the Eth. mode (speed & duplex).
TRAP-TYPE    

mngPortClear 211
Indicates the LAN1 port status changed to connected. Contains two parameters: 1 - Description: LAN1 port status changed to connected - %s 2 - %s Is the Eth. mode (speed & duplex)
TRAP-TYPE    

externalAlarmInPort3Clear 212
This Trap is sent every time an External Alarm Input fault of port # 3 is cleared. Contains a single parameter, which is its description: 1 - Description: External Alarm 3 - - Alarm Cleared.
TRAP-TYPE    

externalAlarmInPort4Clear 213
This Trap is sent every time an External Alarm Input fault of port # 4 is cleared. Contains a single parameter, which is its description: 1 - Description: External Alarm 4 - - Alarm Cleared.
TRAP-TYPE    

swVersionsMatchFullCompatibilityClear 214
The trap is sent if SW versions match. Contains a single parameter, which is its description: 1 - Description: Software Versions compatible
TRAP-TYPE    

swVersionsMatchRestrictedCompatibilityClear 215
The trap is sent if SW versions match and link functionality is not restricted. Contains a single parameter, which is its description: 1 - Description: Software Versions compatible
TRAP-TYPE    

swVersionsMatchSoftwareUpgradeRequiredClear 216
The trap is sent if SW versions match and SW upgrade is successful. Contains a single parameter, which is its description: 1 - Description: Software Versions compatible
TRAP-TYPE    

swVersionsCompatibleClear 217
The trap is sent if SW versions compatible Contains a single parameter, which is its description: 1 - Description: Software Versions compatible
TRAP-TYPE    

hssMultipleSourcesDisappearedClear 218
Indicates that multiple sync pulse sources disappeared. Contains a single parameter, which is its description: 1 - Description: HSS multiple sync pulse sources disappeared.
TRAP-TYPE    

hssSyncToProperSourceAchievedClear 219
Indicates that synchronization to a proper Sync source was achieved. Contains a single parameter, which is its description: 1 - Description: HSS sync pulse - Up.
TRAP-TYPE    

hssSyncPulseDisappearedClear 220
Indicates that HSS additional sync pulse disappeared. Contains a single parameter, which is its description: 1 - Description: HSS additional sync pulse was disappeared.
TRAP-TYPE    

tdmBackupClear 221
Indicates that the TDM main link was activated. Contains a single parameter, which is its description: 1 - Description: TDM main link was activated.
TRAP-TYPE    

linkLockAuthorizedRemoteODU 222
Indicates that the remote ODU is authorized. Contains a single parameter, which is its description: 1 - Description: Authorized remote ODU connection accepted.
TRAP-TYPE    

linkLockAuthorizedODU 223
Indicates that the ODU is authorized. Contains a single parameter, which is its description: 1 - Description: Authorized ODU connection permitted.
TRAP-TYPE    

linkAuthenticationDisabled 224
Indicates that the Link Lock is disabled. Contains a single parameter, which is its description: 1 - Description: Link Authentication has been disabled.
TRAP-TYPE    

hotStandbyClear 225
Indicates that the Primary Link Was Activated. Contains a single parameter, which is its description: 1 - Description: Primary Link Is Active.
TRAP-TYPE    

sfpExtraction 226
Indicates that a device was extracted from SFP Port
TRAP-TYPE    

sfpPort1Clear 227
Indicates the SFP port 1 status changed to connected. Contains two parameters: 1 - Description: SFP port 1 status changed to connected - %s 2 - %s Is the Eth. mode (speed & duplex)
TRAP-TYPE    

compatibleIdus 228
Indicates that the ODU has identified compatible Idus on both sides of the link.
TRAP-TYPE    

desiredRatioCanNotBeAppliedClear 229
Indicates Current UL/DL Ratio Is Equal To Desired Ratio.
TRAP-TYPE    

cbwMatch 230
Indicates that a Channel Bandwidth match was detected. Contains a single parameter, which is its description: 1 - Channel Bandwidth value in MHz.
TRAP-TYPE    

switchCbwAndChannel 231
Indicates that the system is switching Channel Bandwidth and channel frequency. Contains two parameters: 1 - Switching to Channel Bandwith %n0 MHz and to channel %n1 GHz.
TRAP-TYPE    

ringRplStateIdle 232
RPL state changed to Idle.
TRAP-TYPE    

ringEthServiceStatus 233
Indicates Ethernet service's state - blocked \ unblocked. Contains a single parameter: 1 - Description: Ethernet's state (blocked \ unblocked)
TRAP-TYPE    

ringFirstRpmReceived 234
Ring application: in non-RPL link indicates first from a specific RPL was received. Contains a single parameter: 1 - Description: RPM's VLAN ID
TRAP-TYPE    

ringEthernetSrviceUnblockedTO 235
Ring application: in non-RPL link Ethernet service is unblocked due to RPM timeout.
TRAP-TYPE    

gpsSynchronized 236
Indicates that the GPS is synchronized with satellites.
TRAP-TYPE    

hbsEncryptionClear 237
Indicates that encryption is OK. Contains a single parameter, which is its description, including the HSU's name
TRAP-TYPE    

hbsEhServiceOpenedToHsu 238
Indicates that encryption is OK. Contains a single parameter, which is its description, including the HSU's name
TRAP-TYPE    

hbsSynchronizedHsuAlarm 239
Indicates a registered HSU is synchronized.
TRAP-TYPE    

hbsActiveHbs 240
Indicates when HBS has been activated.
TRAP-TYPE    

switchCBW 241
Switching Channel Bandwidth.
TRAP-TYPE    

changeRatio 242
HBS Tx ratio has changed.
TRAP-TYPE    

lanPortClear 243
Indicates the LAN port status changed to connected. Contains two parameters: 1 - Description: LAN port status changed to connected - %s 2 - %s Is the Eth. mode (speed & duplex)
TRAP-TYPE    

poePortClear 244
Indicates the LAN2 port status changed to connected. Contains two parameters: 1 - Description: LAN2 port status changed to connected - %s 2 - %s Is the Eth. mode (speed & duplex)
TRAP-TYPE    

poePowerConsumptionClear 245
Indicates the POE power consumption is valid. Contains two parameters: 1 - Description: POE consumption within limits. port is opened. 2 - %s Is the Eth. mode (speed & duplex)
TRAP-TYPE    

incompatibleHbsHsu 246
Incompatible HBS/HSU software versions - no service.
TRAP-TYPE    

mobilityLinkOff 247
Mobility - Link cannot be established due to: 1 - The HBS does not support Mobility 2 - Lack of resources in the HBS for HSU level
TRAP-TYPE    

enterLocalConnection 248
Entering Local Connection (Broadcast) Mode.
TRAP-TYPE    

hobupActiveStateFaultyClear 249
this clear alarm will indicate that the Hot Backup unit is in active state. Contains a single parameter, which is its description: 1 - Description: Hot Backup %s unit activated. %s - Primary Or Secondary Unit
TRAP-TYPE    

hobupStandbyState 250
This info fault will indicate that the Hot backup module has entered standby/peer_detection state Contains a single parameter, which is its description: 1 - Description: Hot Backup in Standby state: %s unit. %s - Primary Or Secondary Unit
TRAP-TYPE    

gpsOverCurrentClear 251
Indicates the GPS Antenna current consumption is valid.
TRAP-TYPE    

temperatureThresholdClear 252
Indicates the board temperature is valid.
TRAP-TYPE    

localRouterDiscoverySucceed 253
Indicated the we succeeded to discover train router in ip %s MAC address %s %s Train IP %s Train MAC Address
TRAP-TYPE    

trackRouterDiscoverySucceed 254
Indicated the we succeeded to discover track router in ip %s MAC address %s %s Train IP %s Train MAC Address
TRAP-TYPE    

qosVersion2StrictMismatch 255
CPE doesn't support strict QOS configuration.
TRAP-TYPE    

qosVersion2TtlMismatch 256
CPE doesn't support TTL configuration.
TRAP-TYPE    

btsTargetIsReachable 257
Indicated the we succeeded to establish connection with the Bts desired target (%s) %s Target IP
TRAP-TYPE    

tcNotSupportedByHSU 258
CPE doesn't support TC functionality.
TRAP-TYPE    

syncEPortHOStateChange 259
Enter/leave HO state of SyncE port.
TRAP-TYPE    

syncEPortFailureStateChange 260
Enter/leave Failure state of SyncE port.
TRAP-TYPE    

btsCpeUpdateServiceFailed 261
Update service Failed
TRAP-TYPE    

btsCpeUpdateServiceSucceed 262
Update service Succeed
TRAP-TYPE    

radiusServerNoREsponse 263
No response from radius server
TRAP-TYPE    

noRadiusServerRespond 264
Alarm indicates that no Radius server is connected
TRAP-TYPE    

radiusServerRespondedSuccessfully 265
indicates that Radius server responded seccessfully.
TRAP-TYPE    

bsaAlignmentStarted 266
Indicate the beginning of Alignment Process
TRAP-TYPE    

bsaAlignmentFinished 267
Indicate the completion of Alignment Process
TRAP-TYPE    

bsaAlignmentTriggered 268
Indicate the triggering of Alignment Process due to exceeding thresholds
TRAP-TYPE    

radwinProducts 1.3.6.1.4.1.4458.20
OBJECT IDENTIFIER    

winlink1000Family 1.3.6.1.4.1.4458.20.2
OBJECT IDENTIFIER    

radwin2000Family 1.3.6.1.4.1.4458.20.3
OBJECT IDENTIFIER    

gpsSynchronizerFamily 1.3.6.1.4.1.4458.20.4
OBJECT IDENTIFIER    

radwin5000HBSFamily 1.3.6.1.4.1.4458.20.5
OBJECT IDENTIFIER    

radwin5000HSUFamily 1.3.6.1.4.1.4458.20.6
OBJECT IDENTIFIER    

radwin6000Family 1.3.6.1.4.1.4458.20.10
OBJECT IDENTIFIER    

radwinWiFiAPFamily 1.3.6.1.4.1.4458.20.20
OBJECT IDENTIFIER    

odu 1.3.6.1.4.1.4458.20.2.1
OBJECT IDENTIFIER    

oduIntegratedAntenna 1.3.6.1.4.1.4458.20.2.1.1
OBJECT IDENTIFIER    

oduExternalAntenna 1.3.6.1.4.1.4458.20.2.1.2
OBJECT IDENTIFIER    

odu2000 1.3.6.1.4.1.4458.20.3.1
OBJECT IDENTIFIER    

odu2KIntegratedAntenna 1.3.6.1.4.1.4458.20.3.1.1
OBJECT IDENTIFIER    

odu2KExternalAntenna 1.3.6.1.4.1.4458.20.3.1.2
OBJECT IDENTIFIER    

oduGSU 1.3.6.1.4.1.4458.20.4.1
OBJECT IDENTIFIER    

oduGSUExternalAntenna 1.3.6.1.4.1.4458.20.4.1.2
OBJECT IDENTIFIER    

hssSyncUnits 1.3.6.1.4.1.4458.20.4.2
OBJECT IDENTIFIER    

hssISU 1.3.6.1.4.1.4458.20.4.2.1
OBJECT IDENTIFIER    

hssGSU 1.3.6.1.4.1.4458.20.4.2.2
OBJECT IDENTIFIER    

oduHBS 1.3.6.1.4.1.4458.20.5.1
OBJECT IDENTIFIER    

oduHBSIntegratedAntenna 1.3.6.1.4.1.4458.20.5.1.1
OBJECT IDENTIFIER    

oduHBSExternalAntenna 1.3.6.1.4.1.4458.20.5.1.2
OBJECT IDENTIFIER    

oduHSU 1.3.6.1.4.1.4458.20.6.1
OBJECT IDENTIFIER    

oduHSUIntegratedAntenna 1.3.6.1.4.1.4458.20.6.1.1
OBJECT IDENTIFIER    

oduHSUExternalAntenna 1.3.6.1.4.1.4458.20.6.1.2
OBJECT IDENTIFIER    

odu6000 1.3.6.1.4.1.4458.20.10.1
OBJECT IDENTIFIER    

odu6K 1.3.6.1.4.1.4458.20.10.1.1
OBJECT IDENTIFIER    

gateway6000 1.3.6.1.4.1.4458.20.10.2
OBJECT IDENTIFIER    

gateway6K 1.3.6.1.4.1.4458.20.10.2.1
OBJECT IDENTIFIER    

odu600 1.3.6.1.4.1.4458.20.20.1
OBJECT IDENTIFIER    

oduWiFiAP 1.3.6.1.4.1.4458.20.20.1.1
OBJECT IDENTIFIER