RAD-MIB

File: RAD-MIB.mib (1910536 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC IF-MIB
PerfHist-TC-MIB SNMP-FRAMEWORK-MIB Q-BRIDGE-MIB
DS3-MIB IANAifType-MIB DS1-MIB
BRIDGE-MIB ATM-MIB INET-ADDRESS-MIB
DISMAN-SCHEDULE-MIB LLDP-MIB DOT3-OAM-MIB
IEEE8021-CFM-MIB

Imported symbols

TimeTicks enterprises IpAddress
OBJECT-TYPE Integer32 Counter32
Gauge32 OBJECT-IDENTITY NOTIFICATION-TYPE
Unsigned32 Counter64 RowStatus
DateAndTime TimeStamp TEXTUAL-CONVENTION
DisplayString MacAddress RowPointer
TruthValue InterfaceIndex ifAlias
ifIndex ifDescr PerfCurrentCount
PerfIntervalCount PerfTotalCount SnmpAdminString
VlanId PortList dot1qVlanStaticEntry
dsx3LineStatus dsx3LoopbackStatus dsx3ConfigEntry
IANAifType dsx1CurrentIndex dsx1IntervalIndex
dsx1IntervalNumber dsx1LineIndex dsx1TotalIndex
dsx1LineStatus dsx1LineStatusLastChange dsx1LoopbackStatus
Timeout BridgeId dot1dBasePortEntry
atmVplVpi atmVclVpi atmVclVci
atmVpCrossConnectEntry atmVcCrossConnectEntry atmTrafficDescrParamEntry
InetAddressType InetAddress schedEntry
LldpPortIdSubtype dot3OamEntry dot3OamOperStatus
dot1agCfmMdIndex dot1agCfmMaIndex dot1agCfmMepIdentifier
dot1agCfmMepDbRMepIdentifier

Defined Types

MngEntry  
SEQUENCE    
  mngID Integer32
  mngIP IpAddress
  mngIPMask IpAddress
  mngTrapMask Integer32
  mngAlarmTrapMask OCTET STRING
  mngSnmpTrapUdpPort Unsigned32

TrapEntry  
SEQUENCE    
  trapID Integer32
  trapVal DisplayString
  trapTimeSinceOccurrence TimeTicks
  trapNumeric Integer32

IntSwdlEntry  
SEQUENCE    
  intSwdlObjIdx Integer32
  intSwdlFileIdx Integer32
  intSwdlFileName DisplayString
  intSwdlFileSwVer DisplayString
  intSwdlSwDate DisplayString
  intSwdlSize DisplayString
  intSwdlCmd INTEGER
  intSwdlToSubSystem OCTET STRING
  intSwdlCardType INTEGER
  intSwdlFlashIdx Integer32

SwdlStatusEntry  
SEQUENCE    
  swdlStatusTypeIdx Integer32
  swdlStatusIdx Integer32
  swdlStatusFileName DisplayString
  swdlStatusSlot DisplayString
  swdlStatusSubSystem DisplayString
  swdlStatusStatus Integer32
  swdlStatusTime DisplayString

AutoFileTransferEntry  
SEQUENCE    
  autoFileTransferType INTEGER
  autoFileTransferServerIp IpAddress
  autoFileTransferFileName SnmpAdminString
  autoFileTransferScheduling INTEGER
  autoFileTransferTimeRecurrence Integer32
  autoFileTransferOccurrenceRecurrence Integer32

SchedXEntry  
SEQUENCE    
  schedYear Unsigned32
  schedWeekInMonth INTEGER
  schedParam Integer32

PhysicalConnectorEntry  
SEQUENCE    
  portIdx Integer32
  physicalConnector INTEGER
  portOptWaveLength INTEGER
  portOptMode INTEGER
  portBalance INTEGER
  portDdmSupport INTEGER
  portMfgName SnmpAdminString
  portTypicalMaxRange Unsigned32
  physicalConnectorString SnmpAdminString
  portVendorPartNo SnmpAdminString

PrtSpEntry  
SEQUENCE    
  prtSupervisoryIndex Integer32
  prtSupervisoryRate INTEGER
  prtSupervisoryDataBits INTEGER
  prtSupervisoryParity INTEGER
  prtSupervisoryStopBits INTEGER
  prtSupervisoryUsage INTEGER
  prtSupervisoryInterface INTEGER
  prtSupervisoryCTS INTEGER
  prtSupervisoryDcdDelay INTEGER
  prtSupervisoryDSR INTEGER
  prtSupervisoryRoutProtocol INTEGER

PrtPerfEntry  
SEQUENCE    
  prtPerfIdx Integer32
  prtPerfPeriodRef INTEGER
  prtPerfElapsedTime Integer32
  prtPerfUAS Integer32
  prtPerfES Integer32
  prtPerfSES Integer32
  prtPerfBBE Integer32
  prtPerfBlocksPerSec Integer32
  prtPerfTimeTag TimeTicks
  prtPerfSaveAndResetCmd INTEGER

PrtTestEntry  
SEQUENCE    
  prtTestIdx Integer32
  prtTestCmdAndStatus Integer32
  prtBertCounter Integer32
  prtTestInitiator INTEGER
  prtTestTimeout Integer32
  prtTestVctRxResult INTEGER
  prtTestVctTxResult INTEGER
  prtTestVctRxDistance Integer32
  prtTestVctTxDistance Integer32
  prtTestVctCmd INTEGER
  prtTestVctRxCrossPair Integer32
  prtTestVctTxCrossPair Integer32
  prtTestActivationDelay Unsigned32
  prtTestMacSwapLoopDataMode INTEGER
  prtTestMacSwapLoopVlanId Integer32
  prtTestMacSwapLoopDirection INTEGER
  prtTestMacSwapLoopDestAddr MacAddress
  prtTestMacSwapLoopSrcAddr MacAddress
  prtTestOamMinRoundTripDelay Unsigned32
  prtTestOamMaxRoundTripDelay Unsigned32
  prtTestOamAvgRoundTripDelay Unsigned32
  prtTestOamTxInterval Unsigned32
  prtTestDestinationIpAddress IpAddress
  prtTestTTL Unsigned32
  prtTestBwProfile Unsigned32

PrtParamEntry  
SEQUENCE    
  prtParamIdx Integer32
  prtControlCnfg Integer32
  prtParamClkSrc INTEGER
  prtParamPhantom INTEGER
  prtParamResetStatsCmd INTEGER
  prtParamLastResetStatsTime TimeStamp
  prtParamInterfaceType INTEGER
  prtParamClearAlarm INTEGER
  prtParamLeds OCTET STRING
  prtParamLineLength INTEGER
  prtParamUsage INTEGER
  prtParamMappingMode INTEGER
  prtParamAlarmIndication INTEGER
  prtParamClkQualityLevel OCTET STRING
  prtParamClkWaveShape INTEGER
  prtParamStatus INTEGER
  prtParamSignalLevel Integer32
  prtParamClkUserQualityLevel OCTET STRING
  prtParamDataRate Unsigned32
  prtParamLoopDetect INTEGER
  prtParamActUponLoopDetect OCTET STRING
  prtParamPSNLayer INTEGER
  prtParamRxSsm INTEGER
  prtParamClkSsmRxSource INTEGER
  prtParamFarEndDevice Unsigned32
  prtParamTxClk INTEGER

PrtIpParamEntry  
SEQUENCE    
  prtIpParamConfigIdx Integer32
  prtIpParamSlotIdx Integer32
  prtIpParamIdx Integer32
  prtIpParamHostIP IpAddress
  prtIpParamHostMask IpAddress
  prtIpParamDefaultGateway IpAddress
  prtIpParamMediaMode INTEGER
  prtIpParamMediaRate INTEGER
  prtIpParamMngVlanSupport INTEGER
  prtIpParamMngVlanId Integer32
  prtIpParamMngVlanPriority Integer32
  prtIpParamRingMode INTEGER
  prtIpParamProtIpEnable INTEGER
  prtIpParamTrafficPriority INTEGER
  prtIpParamRemoteIP IpAddress
  prtIpParamMaxTxBandwidth INTEGER
  prtIpParamTos Integer32
  prtIpParamConnect INTEGER
  prtIpParamAgingTime Integer32
  prtIpParamEncapsulationProt INTEGER
  prtIpParamEncapProtPort Integer32
  prtIpParamVlanSupport INTEGER
  prtIpParamVlanId Integer32
  prtIpParamVlanPriority Integer32
  prtIpParamDoubleTagVlanId Integer32
  prtIpParamDoubleTagVlanPriority Integer32
  prtIpParamVlanTagging INTEGER
  prtIpParamRateLimit Integer32
  prtIpParamDefInterface Integer32
  prtIpParamMng INTEGER
  prtIpParamFloodedRateLimit Integer32
  prtIpParamBurstSize Unsigned32
  prtIpParamLimitPacketType INTEGER
  prtIpParamKeepAliveInterval Integer32
  prtIpParamKeepAliveThresh Integer32
  prtIpParamP2pKeepAliveVlanId Integer32
  prtIpParamP2pKeepAliveVlanPrio Integer32
  prtIpParamRingAdjacentMacAddr MacAddress

PrtClkSrcEntry  
SEQUENCE    
  prtClkSrcCnfgIdx Integer32
  prtClkSrcPrtIdx Integer32
  prtClkSrcIdx INTEGER
  prtClkSrcMode INTEGER
  prtClkSrcPrt Integer32

OptPrtMonitorEntry  
SEQUENCE    
  optPrtMonitorPrtIdx Integer32
  optPrtMonitorSample INTEGER
  optPrtMonitorTxPower Integer32
  optPrtMonitorLaserBias Integer32
  optPrtMonitorLaserTemp Integer32
  optPrtMonitorRxPower Integer32
  optPrtMonitorSupplyVoltage Integer32

OptPrtCnfgEntry  
SEQUENCE    
  optPrtCnfgIdx Unsigned32
  optPrtCnfgPrtIdx Unsigned32
  optPrtCnfgALS INTEGER

SystemPsEntry  
SEQUENCE    
  systemPsIndex1 Integer32
  systemPsIndex2 Integer32
  systemPsType INTEGER
  systemPsStatus INTEGER
  systemPsHotSwap INTEGER

XcEntry  
SEQUENCE    
  xcIndex Integer32
  xcIfIndex1 Integer32
  xcVpi Integer32
  xcVci Integer32
  xcIfIndex2 Integer32
  xcRowStatus RowStatus
  xcDescr DisplayString
  xcAdminStatus INTEGER
  xcOperStatus INTEGER
  xcAttachedIfType INTEGER
  xcInputPriority Integer32
  xcBitMapping Integer32

ModlParamEntry  
SEQUENCE    
  modlParamIndex Integer32
  modlParamReset INTEGER
  modlParamSwdlStatus INTEGER
  modlParamLeds OCTET STRING
  modlParamType INTEGER
  modlParamSwVer DisplayString

SysIfEntityType  
INTEGER other(1), ethernetLan(6), atm(37), fastEther(62), ipForward(142), teLink(200), bridge(209)    

IfCreateEntry  
SEQUENCE    
  ifCreateEntityType SysIfEntityType
  ifCreateEntityIdx Integer32
  ifCreateNumber Integer32
  ifCreateRowStatus RowStatus
  ifCreateType IANAifType
  ifCreateIndex Integer32
  ifCreateConnectedTo Integer32
  ifCreateParams Unsigned32
  ifCreateConnectionPointer RowPointer

IfPerfEntry  
SEQUENCE    
  ifPerfCounterType Integer32
  ifPerfLowCounterPart Unsigned32
  ifPerfHighCounterPart Unsigned32
  ifPerfHCCounter Counter64

SystemOamEntry  
SEQUENCE    
  systemOamCnfgIdx Integer32
  systemOamFrequency Integer32
  systemOamTimeoutCycles Integer32
  systemOamLinkCheck INTEGER

SystemOamDescrEntry  
SEQUENCE    
  systemOamDescrIdx Integer32
  systemOamDescrRowStatus RowStatus
  systemOamDescrMode INTEGER
  systemOamDescrCCDirection INTEGER
  systemOamDescrLoopbackOperation INTEGER
  systemOamDescrLoopbackDestAddr OCTET STRING
  systemOamDescrXcCounter Gauge32

BitMappingEntry  
SEQUENCE    
  bitMappingLocation Integer32
  bitMappingIndex Integer32

HostEntry  
SEQUENCE    
  hostIndex Integer32
  hostIP IpAddress
  hostIPMask IpAddress
  hostDefaultNextHop IpAddress
  hostMode Integer32
  hostParam1 Integer32
  hostParam2 Integer32
  hostParam3 Integer32
  hostRowStatus RowStatus
  hostVlanTagging INTEGER
  hostVlanId Integer32
  hostVlanPriority Integer32

InvNameXCEntry  
SEQUENCE    
  invNameXC SnmpAdminString
  invNameXCType OBJECT IDENTIFIER
  invNameXCIndex Integer32

RowInfoEntry  
SEQUENCE    
  rowInfoTableId OBJECT IDENTIFIER
  rowInfoCounter Integer32
  rowInfoIndexNext Integer32
  rowInfoMaxNoOfRows Integer32

AgnFunctionEntry  
SEQUENCE    
  agnFunction INTEGER
  agnFunctionActivation INTEGER

AlarmForwardingEntry  
SEQUENCE    
  alarmForwardingFailPort Integer32
  alarmForwardingToPort Integer32
  alarmForwardingRowStatus RowStatus
  alarmForwardingRecoveryTime Integer32
  alarmForwardingGroupConditions Integer32
  alarmForwardingCause BITS
  alarmForwardingRecoveryMode INTEGER
  alarmForwardingRecoveryCommand INTEGER
  alarmForwardingDelay Unsigned32
  alarmForwardingDirection INTEGER
  alarmForwardingAction BITS

AgnClkSrcPortEntry  
SEQUENCE    
  agnClkSrcPortCnfgIdx Integer32
  agnClkSrcPortSrcIdx INTEGER
  agnClkSrcPortIdx Integer32
  agnClkSrcPort Integer32
  agnClkSrcPortRowStatus RowStatus
  agnClkSrcPortAdminStatus INTEGER
  agnClkSrcPortType INTEGER
  agnClkSrcPortQuality INTEGER
  agnClkSrcPortNetType INTEGER
  agnClkSrcPortState INTEGER

AgnCurrClkEntry  
SEQUENCE    
  agnCurrClkObjIdx Integer32
  agnCurrClkMode INTEGER
  agnCurrClkSrc INTEGER
  agnCurrClkPort Integer32
  agnCurrClkHoldover INTEGER
  agnCurrClkSsmBased INTEGER
  agnCurrClkState INTEGER
  agnCurrClkQualification INTEGER

AgnClkCurrentEntry  
SEQUENCE    
  agnClkCurrentIndex Unsigned32
  agnClkCurrentRxPackets Gauge32
  agnClkCurrentLostPackets Gauge32
  agnClkCurrentOutOfOrderPackets Gauge32
  agnClkCurrentBufferUnderflow Gauge32

AgnClkIntervalEntry  
SEQUENCE    
  agnClkIntervalIndex Unsigned32
  agnClkIntervalNumber Unsigned32
  agnClkIntervalRxPackets Gauge32
  agnClkIntervalLostPackets Gauge32
  agnClkIntervalOutOfOrderPackets Gauge32
  agnClkIntervalBufferUnderflow Gauge32

LagEntry  
SEQUENCE    
  lagCnfgIdx Unsigned32
  lagIdx Unsigned32
  lagPortMembers PortList
  lagDistributionMethod INTEGER
  lagRecoveryMode INTEGER
  lagWaitToRestore Unsigned32
  lagRowStatus RowStatus
  lagShutDownDurationUponFlip Unsigned32
  lagRdnMethod INTEGER
  lagLacpEnable INTEGER

LagStatEntry  
SEQUENCE    
  lagStatForcePort Unsigned32
  lagStatActivePort Unsigned32

GfpCnfgEntry  
SEQUENCE    
  gfpCnfgIdx Unsigned32
  gfpPayloadFcs INTEGER
  gfpRxTxScramble INTEGER
  gfpVcatHeader INTEGER

AgnGroupEntry  
SEQUENCE    
  agnGroupCnfgIdx Unsigned32
  agnGroupIdx Unsigned32
  agnGroupComponentIdx Unsigned32
  agnGroupRowStatus RowStatus

AgnStringToIndexEntry  
SEQUENCE    
  agnStringToIndexTableId OBJECT IDENTIFIER
  agnStringToIndexUserName SnmpAdminString
  agnStringToIndexTableIndex Unsigned32

AgnRowPointerEntry  
SEQUENCE    
  agnRowPointerIndex OBJECT IDENTIFIER
  agnRowPointerNoOfUsages Unsigned32

RadTransportAddressType  
A value that represents a transport domain. This is the enumerated version of the transport domain registrations in this MIB module. It was added in RAD MIB due to the fact that it is not defined in Standard MIB. The enumerated values have the following meaning: unknown(0) unknown transport address type efmOam (1) radTransportDomainSnmpEfmOam This textual convention can be used to represent transport domains in situations where a syntax of TransportDomain is unwieldy (for example, when used as an index). The usage of this textual convention implies that additional transport domains can only be supported by updating this MIB module.
TEXTUAL-CONVENTION    
  INTEGER unknown(0), efmOam(1)  

RadTransportAddressEfmOam  
Represents a transport address consisting of an EFM OAM port number.
TEXTUAL-CONVENTION    
  OCTET STRING Size(4)  

RadBridgeMaskEntry  
SEQUENCE    
  radBridgeMaskType INTEGER
  radBridgeMaskIfIndex Integer32
  radBridgeMaskNum Integer32
  radBridgeMaskDest INTEGER
  radBridgeMaskPat1 OCTET STRING
  radBridgeMaskActiveBit1 OCTET STRING
  radBridgeMaskFrom1 INTEGER
  radBridgeMaskOffset1 Integer32
  radBridgeMaskCond1 INTEGER
  radBridgeMaskPat2 OCTET STRING
  radBridgeMaskActiveBit2 OCTET STRING
  radBridgeMaskFrom2 INTEGER
  radBridgeMaskOffset2 Integer32
  radBridgeMaskCond2 INTEGER
  radBridgeMaskPat3 OCTET STRING
  radBridgeMaskActiveBit3 OCTET STRING
  radBridgeMaskFrom3 INTEGER
  radBridgeMaskOffset3 Integer32
  radBridgeMaskCond3 INTEGER
  radBridgeMaskOper INTEGER

RadBridgeCODEntry  
SEQUENCE    
  radBridgeCODIfIndex Integer32
  radBridgeCODManualConnect INTEGER
  radBridgeCODMode INTEGER
  radBridgeCODConnectDelay Integer32
  radBridgeCODisConnectDelay Integer32
  radBridgeCODImplicitSwitch INTEGER
  radBridgeCODNumAccess Counter32
  radBridgeCODTotalConnecTime Integer32

RadBridgeCODTimeTriggerEntry  
SEQUENCE    
  radBridgeCODTimeIfIndex Integer32
  radBridgeCODDay INTEGER
  radBridgeCODTimeTriggerNum Integer32
  radBridgeCODTimeTriggerFrom DisplayString
  radBridgeCODTimeTriggerTo DisplayString
  radBridgeCODTimeTriggerStatus INTEGER

RadBridgeCODTrafficEntry  
SEQUENCE    
  radBridgeCODProtocolType INTEGER
  radBridgeCODTrafficTriggerStatus INTEGER

RadBridgeCODCondEntry  
SEQUENCE    
  radBridgeCODCondIfIndex Integer32
  radBridgeCODOriginateConnectCondition INTEGER
  radBridgeCODOriginateDisConnectCondition INTEGER
  radBridgeCODOriginateDisConnectDelay Integer32
  radBridgeCODAnswerConnectCondition INTEGER
  radBridgeCODSpecificOnTrafficOIDCondition OBJECT IDENTIFIER
  radBridgeCODDisConnectMinimunFramesNumber Integer32

RadBridgeIPXRipTableEntry  
SEQUENCE    
  radBridgeIPXRipDestNetwork OCTET STRING
  radBridgeIPXRipPolicy INTEGER
  radBridgeIPXRipForwardingRouter OCTET STRING
  radBridgeIPXRipNIC Integer32
  radBridgeIPXRipTickMetric Integer32
  radBridgeIPXRipHopMetric Integer32
  radBridgeIPXRipAgingTime TimeTicks
  radBridgeIPXRipValueStatus INTEGER
  radBridgeIPXRipForwardType INTEGER

RadBridgeIPXRipInfEntry  
SEQUENCE    
  radBridgeIPXRipInfIfIndex Integer32
  radBridgeIPXRipInfBcastUpdate Integer32
  radBridgeIPXRipInfAgeMultiplier Integer32

RadBridgeIPXSapTableEntry  
SEQUENCE    
  radBridgeIPXSapServerType Integer32
  radBridgeIPXSapName DisplayString
  radBridgeIPXSapNetwork OCTET STRING
  radBridgeIPXSapNode OCTET STRING
  radBridgeIPXSapSocket Integer32
  radBridgeIPXSapHopsToServer Integer32
  radBridgeIPXSapNIC Integer32
  radBridgeIPXSapAgingTime TimeTicks
  radBridgeIPXSapStatus INTEGER

RadBridgeIPXSapInfEntry  
SEQUENCE    
  radBridgeIPXSapInfIfIndex Integer32
  radBridgeIPXSapInfBcastUpdate Integer32
  radBridgeIPXSapInfAgeMultiplier Integer32

GenAddress  
OCTET STRING Size(12)    

MaskingEntry  
SEQUENCE    
  maskingType INTEGER
  maskingIfIndex Integer32
  maskingIndex Integer32
  maskingProtocolType INTEGER
  maskingSmartMaskOID OBJECT IDENTIFIER
  maskingFrameType INTEGER
  maskingFrameTypeCondition INTEGER
  maskingSourceAddress GenAddress
  maskingSourceActiveBits GenAddress
  maskingSourceMacOrNet INTEGER
  maskingSourceCondition INTEGER
  maskingDestAddress GenAddress
  maskingDestActiveBits GenAddress
  maskingDestMacOrNet INTEGER
  maskingDestCondition INTEGER
  maskingLowLevelProt INTEGER
  maskingLowLevelProtCondition INTEGER
  maskingHighLevelProt Integer32
  maskingHighLevelProtCondition INTEGER
  maskingPortNum Integer32
  maskingPortNumCondition INTEGER
  maskingOperation INTEGER
  maskingSrcPortNum Integer32
  maskingSrcPortNumCondition INTEGER

RadBridgeCurrentEntry  
SEQUENCE    
  radBridgeCurrentIndex Integer32
  radBridgeCurrentIngressFilteringDiscardedFrames Gauge32
  radBridgeCurrentFrameTypeDiscardedFrames Gauge32
  radBridgeCurrentRxCorrectFrames Gauge32
  radBridgeCurrentRxCorrectBytes Gauge32
  radBridgeCurrentRxCorrectBytesHCOverflow Gauge32
  radBridgeCurrentRxBcastFrames Gauge32
  radBridgeCurrentRxMcastFrames Gauge32
  radBridgeCurrentTxCorrectFrames Gauge32
  radBridgeCurrentTxCorrectBytes Gauge32
  radBridgeCurrentTxCorrectBytesHCOverflow Gauge32
  radBridgeCurrentTxBcastFrames Gauge32
  radBridgeCurrentTxMcastFrames Gauge32
  radBridgeCurrentTxDropFrames Gauge32

RadBridgeIntervalEntry  
SEQUENCE    
  radBridgeIntervalIndex Integer32
  radBridgeIntervalNumber Integer32
  radBridgeIntervalIngressFilteringDiscardedFrames Gauge32
  radBridgeIntervalFrameTypeDiscardedFrames Gauge32
  radBridgeIntervalRxCorrectFrames Gauge32
  radBridgeIntervalRxCorrectBytes Gauge32
  radBridgeIntervalRxCorrectBytesHCOverflow Gauge32
  radBridgeIntervalRxBcastFrames Gauge32
  radBridgeIntervalRxMcastFrames Gauge32
  radBridgeIntervalTxCorrectFrames Gauge32
  radBridgeIntervalTxCorrectBytes Gauge32
  radBridgeIntervalTxCorrectBytesHCOverflow Gauge32
  radBridgeIntervalTxBcastFrames Gauge32
  radBridgeIntervalTxMcastFrames Gauge32
  radBridgeIntervalTxDropFrames Gauge32

RadBridgePortBaseVlanEntry  
SEQUENCE    
  radBridgePortBaseVlanCnfgIdx Integer32
  radBridgePortBaseVlanIdx Integer32
  radBridgePortBaseVlanName SnmpAdminString
  radBridgePortBaseVlanEgressPorts PortList
  radBridgePortBaseVlanVirtualGroups PortList
  radBridgePortBaseVlanRowStatus RowStatus
  radBridgePortBaseVlanMng INTEGER

RadBridgePortVlanMemberEntry  
SEQUENCE    
  radBridgePortVlanMemberBridgeIdx Integer32
  radBridgePortVlanMemberPortIdx Integer32
  radBridgePortVlanMemberVlanId Integer32
  radBridgePortVlanMemberRowStatus RowStatus

RadBridgeGenFlowEntry  
SEQUENCE    
  radBridgeGenFlowCnfgIdx Integer32
  radBridgeGenFlowIdx Integer32
  radBridgeGenFlowRowStatus RowStatus
  radBridgeGenFlowFloodOrBcastMaxRate Integer32
  radBridgeGenFlowQosMode INTEGER
  radBridgeGenFlowSchedulingMode INTEGER
  radBridgeGenFlowBasicClassification INTEGER
  radBridgeGenFlowMulticastTrafficClass Integer32
  radBridgeGenFlowBroadcastTrafficClass Integer32
  radBridgeGenFlowUnkownUnicastTrafficClass Integer32

RadBridgeDot1qVlanStaticEntry  
SEQUENCE    
  radBridgeDot1qVlanTaggedPorts PortList
  radBridgeDot1qVlanUnmodifiedPorts PortList
  radBridgeDot1qVlanSplitHorizon INTEGER

RadBridgeInvBasePortEntry  
SEQUENCE    
  radBridgeInvBasePortIfIndex Integer32
  radBridgeInvBasePort Integer32

RadBridgeStpCnfgEntry  
SEQUENCE    
  radBridgeStpCnfgIdx1 Integer32
  radBridgeStpCnfgIdx2 Integer32
  radBridgeStpCnfgForwardDelay Timeout
  radBridgeStpCnfgMaxAge Timeout
  radBridgeStpCnfgHelloTime Timeout
  radBridgeStpCnfgPriority Integer32
  radBridgeStpCnfgStpVersion INTEGER

RadBridgeStpStatEntry  
SEQUENCE    
  radBridgeStpStatIdx Integer32
  radBridgeStpStatForwardDelay Timeout
  radBridgeStpStatMaxAge Timeout
  radBridgeStpStatHelloTime Timeout
  radBridgeStpStatDesignatedRoot BridgeId
  radBridgeStpStatRootCost Integer32

RadBridgePortCnfgEntry  
SEQUENCE    
  radBridgePortCnfgIdx Integer32
  radBridgePortCnfgPrtIdx Integer32
  radBridgePortCnfgMaxMacAddr Integer32
  radBridgePortCnfgMngFlow INTEGER
  radBridgePortCnfgMcastMode INTEGER
  radBridgePortCnfgDefaultVpi Integer32
  radBridgePortCnfgDefaultVci Integer32
  radBridgePortCnfgStatVlanId Integer32
  radBridgePortCnfgIngressMtu Integer32
  radBridgePortCnfgEgressMtu Integer32
  radBridgePortCnfgDot1x INTEGER

RadDot1qPortVlanEntry  
SEQUENCE    
  radDot1qPortStacking INTEGER
  radDot1qPortCopyOriginVlanPriority INTEGER
  radDot1qPortDefaultVlanPriority Integer32
  radDot1qPortTagStripping INTEGER
  radDot1qPortEgressTagHandling INTEGER
  radDot1qPortIngressTagHandling INTEGER
  radDot1qPortReplaceVlanPriority INTEGER
  radDot1qPortVlanEthType Unsigned32
  radDot1qPortVlanCnodeLevel1Agent INTEGER

RadBridgeGenCfgEntry  
SEQUENCE    
  radBridgeGenCfgIdx Integer32
  radBridgeGenCfgIdx2 Integer32
  radBridgeGenCfgBridgeAction INTEGER
  radBridgeAgingTimeSec INTEGER
  radBridgeMngVlanId Unsigned32
  radBridgeLoopDetectVlanId Unsigned32
  radBridgeSplitHorizon INTEGER
  radBridgeEthType Unsigned32

AgnSAlrEntry  
SEQUENCE    
  agnSAlrIdx Integer32
  agnSAlrCodeDescription DisplayString
  agnSAlrCode Integer32
  agnSAlrSeverity INTEGER
  agnSAlrState INTEGER
  agnSAlrCounter Integer32
  agnSAlrMask INTEGER
  agnSAlrInvert INTEGER

AgnSErrListEntry  
SEQUENCE    
  agnSErrIdx Integer32
  agnSErrDescription DisplayString

AgnSCnfgEntry  
SEQUENCE    
  agnSEntryIdx Integer32
  agnSEntryIsValid INTEGER

AgnCClkSrcEntry  
SEQUENCE    
  agnCClkCnfgIdx Integer32
  agnCClkSrcIdx Integer32
  agnCClkSrcMode INTEGER
  agnCClkSrcSlt INTEGER
  agnCClkSrcPrt Integer32

AgnCnfgDataEntry  
SEQUENCE    
  agnCnfgIdx Integer32
  agnCnfgDesc DisplayString
  agnCnfgUpdDate DisplayString
  agnCnfgUpdTime DisplayString
  agnCnfgUpdMnger IpAddress

AgnCnfgAlrEntry  
SEQUENCE    
  agnCnfgAlrCode Integer32
  agnCnfgAlrSlot INTEGER
  agnCnfgAlrPort Integer32
  agnCnfgAlrMask INTEGER
  agnCnfgAlrInvert INTEGER
  agnCnfgAlrFilter INTEGER
  agnCnfgAlrFilterSet Integer32
  agnCnfgAlrFilterReset Integer32
  agnCnfgAlrSeverity INTEGER

AgnCnfgAlrReportEntry  
SEQUENCE    
  agnCnfgAlrReportType INTEGER
  agnCnfgAlrStartReportOn INTEGER
  agnCnfgAlrStartReportOff INTEGER

AgnCT1E1RingEntry  
SEQUENCE    
  agnCT1E1RingCnfgIdx Integer32
  agnCT1E1RingPrimeSlot INTEGER
  agnCT1E1RingPrimePort Integer32
  agnCT1E1RingSecSlot INTEGER
  agnCT1E1RingSecPort Integer32
  agnCT1E1RingRecTime Integer32
  agnCT1E1RingRowStatus RowStatus
  agnCT1E1RingWTR Unsigned32
  agnCT1E1RingDualFailDetection INTEGER

AgnCBuMlEntry  
SEQUENCE    
  agnCBuMlCnfgIdx Integer32
  agnCBuMlRole INTEGER
  agnCBuMlType INTEGER
  agnCBuMlDefaultGateway IpAddress
  agnCBuMlSubnetMask IpAddress
  agnCBuMlOamFrequency Integer32
  agnCBuMlOamTimeoutCycles Integer32
  agnCBuMlWaitToRestore Unsigned32

AgnCQ50Entry  
SEQUENCE    
  agnCQ50CnfgIdx Integer32
  agnCQ50StopCallsThresh Integer32
  agnCQ50DiscardPktThresh Integer32
  agnCQ50BlockNewModemVbdCallsThresh Integer32
  agnCQ50BlockNewModemRelayCallsThresh Integer32

AgnCmprEntry  
SEQUENCE    
  agnCmprTypIdx Integer32
  agnCmprCnfgIdx Integer32
  agnCmprVersion Integer32
  agnCmprObj OCTET STRING

AgnDlciCmprEntry  
SEQUENCE    
  agnDlciCmprCnfgIdx Integer32
  agnDlciCmprVersion Integer32
  agnDlciCmprDlciIdx Integer32
  agnDlciCmprObj OCTET STRING

AgnAlarmsCmprEntry  
SEQUENCE    
  agnAlarmsCmprVersion Integer32
  agnAlarmsCmprAlarmIdx Integer32
  agnAlarmsCmprObj OCTET STRING

AgnAlrBufCmprEntry  
SEQUENCE    
  agnAlrBufCmprVersion Integer32
  agnAlrBufCmprAlarmIdx Integer32
  agnAlrBufCmprObj OCTET STRING

AgnSCmprErrListEntry  
SEQUENCE    
  agnSCmprErrVersion Integer32
  agnSCmprErrIdx Integer32
  agnSCmprErrObj OCTET STRING

AgnTsCmprEntry  
SEQUENCE    
  agnTsCmprVerIdx Integer32
  agnTsCmprCnfgIdx Integer32
  agnTsCmprSlotIdx Integer32
  agnTsCmprPortIdx Integer32
  agnTsCmprPduIdx Integer32
  agnTsCmprData OCTET STRING

AgnXCmprEntry  
SEQUENCE    
  agnXCmprTypIdx Integer32
  agnXCmprVersion Integer32
  agnXCmprIdx3 Integer32
  agnXCmprIdx4 Integer32
  agnXCmprIdx5 Integer32
  agnXCmprIdx6 Integer32
  agnXCmprIdx7 Integer32
  agnXCmprObj OCTET STRING

AgnLinkMapEntry  
SEQUENCE    
  mapLinkId Integer32
  mapLinkSltIdx INTEGER
  mapLinkPrtIdx INTEGER
  mapLinkStatus INTEGER

AlrBufEntry  
SEQUENCE    
  alrBufIdx Integer32
  alrBufDescription DisplayString
  alrBufCode Unsigned32
  alrBufSlot INTEGER
  alrBufPort Unsigned32
  alrBufSeverity INTEGER
  alrBufState INTEGER

AgnCAgendaEntry  
SEQUENCE    
  agnCAgendaCnfgIdx INTEGER
  agnCAgendaDayIdx INTEGER
  agnCAgendaDayCategory INTEGER

AgnCFlipNetEventsEntry  
SEQUENCE    
  agnCFlipNetEventsCnfgIdx INTEGER
  agnCFlipNetEventIdx Integer32
  agnCFlipNetEventActive INTEGER
  agnCFlipNetEventType INTEGER
  agnCFlipNetEventNo Integer32
  agnCFlipNetEventSlot INTEGER
  agnCFlipNetEventPort Integer32
  agnCFlipNetEventISD Integer32
  agnCFlipNetEventOSD Integer32
  agnCFlipNetEventDayType INTEGER
  agnCFlipNetEventStartTime DisplayString
  agnCFlipNetEventEndTime DisplayString

AgnCFlipEntry  
SEQUENCE    
  agnCFlipCnfgIdx INTEGER
  agnCFlipIdx Integer32
  agnCFlipActive INTEGER
  agnCFlipLogicalExp DisplayString
  agnCFlipDbNo Integer32
  agnCFlipDiscardDe INTEGER

AgnListDecodingEntry  
SEQUENCE    
  agnListDecodingType INTEGER
  agnListDecodingCode Integer32
  agnListDecodingDescription DisplayString
  agnListDecodingDefState INTEGER
  agnListDecodingSeverity INTEGER
  agnListDecodingAcmRelaySlt INTEGER
  agnListDecodingAcmRelayPrt INTEGER

AgnDlciEntry  
SEQUENCE    
  agnDlciCnfgIdx Integer32
  agnDlciLSltIdx INTEGER
  agnDlciLPrtIdx Integer32
  agnDlciLIdx Integer32
  agnDlciHSltIdx INTEGER
  agnDlciHPrtIdx Integer32
  agnDlciHIdx Integer32
  agnDlciTxBc INTEGER
  agnDlciTxBe INTEGER
  agnDlciRxBc INTEGER
  agnDlciRxBe INTEGER
  agnDlciPriority Integer32
  agnDlciStatus INTEGER
  agnDlciSpoofing INTEGER
  agnDlciFunnelEnable INTEGER
  agnDlciRoutingProtocol INTEGER
  agnDlciRowStatus RowStatus

AgnVoiceSwConfEntry  
SEQUENCE    
  agnVoiceSwConfIdx INTEGER
  agnVoiceSwConfZoneId DisplayString
  agnVoiceSwConfNodeId DisplayString
  agnVoiceSwConfNoOfHops Integer32
  agnVoiceSwConfSidt Integer32
  agnVoiceSwConfLidt Integer32
  agnVoiceSwConfDialPlan INTEGER

AgnVoiceSwConfRtEntry  
SEQUENCE    
  agnVoiceSwConfRtDbId INTEGER
  agnVoiceSwConfRtIdx Integer32
  agnVoiceSwConfRtDigits DisplayString
  agnVoiceSwConfRtAction INTEGER
  agnVoiceSwConfRtData DisplayString
  agnVoiceSwConfRtSlot INTEGER
  agnVoiceSwConfRtPort Integer32
  agnVoiceSwConfRtDlci Integer32
  agnVoiceSwConfRtRowStatus RowStatus
  agnVoiceSwConfRtMaxCalls Integer32
  agnVoiceSwConfRtPriority Integer32

AgnVoiceSwConfHGEntry  
SEQUENCE    
  agnVoiceSwConfHGdbIdx INTEGER
  agnVoiceSwConfHGIdx Integer32
  agnVoiceSwConfHGConnect INTEGER
  agnVoiceSwConfHGExt Integer32
  agnVoiceSwConfHGExtString SnmpAdminString
  agnVoiceSwConfHGUserParams SnmpAdminString
  agnVoiceSwConfHGStatus INTEGER

AgnSigProfileEntry  
SEQUENCE    
  agnSigProfileCnfgIdx Integer32
  agnSigProfileIdx Integer32
  agnSigProfileRxTx INTEGER
  agnSigProfileABCD OCTET STRING

AgnSigProfEntry  
SEQUENCE    
  agnSigProfCnfgIdx Integer32
  agnSigProfIdx Integer32
  agnSigProfName DisplayString
  agnSigProfType INTEGER

SystemVoiceEntry  
SEQUENCE    
  systemVoiceConfIdx Integer32
  systemVoiceNationalTone INTEGER
  systemVoicePacketRate Unsigned32
  systemVoiceFaxSupport INTEGER
  systemVoiceFaxRate INTEGER
  systemVoiceModemSupport INTEGER
  systemVoiceCoderAndRate INTEGER
  systemVoiceEchoCanceler INTEGER
  systemVoiceTxGain Integer32
  systemVoiceDtmfRelayMethod INTEGER
  systemVoiceDtmfRelayRxPayloadType Unsigned32
  systemVoiceDtmfRelayPayloadTypeNeg INTEGER
  systemVoiceDtmfRelayTxPayloadType Unsigned32

SystemVoiceCoderEntry  
SEQUENCE    
  systemVoiceCoderConfIdx Unsigned32
  systemVoiceCoderPriority Unsigned32
  systemVoiceCoderCoderAndRate INTEGER

MdlSInstEntry  
SEQUENCE    
  mdlSInstSltIdx INTEGER
  mdlSInstCardType INTEGER
  mdlSHwVersion DisplayString
  mdlSSwVersion DisplayString
  mdlSAlrStatus INTEGER
  mdlSAlrStatusAll INTEGER
  mdlSMaskedAlrStat INTEGER
  mdlSMaskedAlrStatAll INTEGER
  mdlSTstStatusAll INTEGER
  mdlSClearAlrCmd INTEGER
  mdlSClearAllAlrCmd INTEGER
  mdlSTemperature Integer32

MdlSAlrEntry  
SEQUENCE    
  mdlSAlrSltIdx INTEGER
  mdlSAlrIdx Integer32
  mdlSAlrCodeDescription DisplayString
  mdlSAlrCode Integer32
  mdlSAlrSeverity INTEGER
  mdlSAlrState INTEGER
  mdlSAlrCounter Integer32
  mdlSAlrMask INTEGER
  mdlSAlrInvert INTEGER

MdlCPrgEntry  
SEQUENCE    
  mdlCCnfgIdx Integer32
  mdlCSltIdx INTEGER
  mdlCPrgCardType INTEGER
  mdlCNoOfExternPrt Integer32
  mdlCNoOfInternPrt Integer32
  mdlCWorkMode INTEGER
  mdlCDhcpClientEnable INTEGER
  mdlCRdnExists INTEGER
  mdlCInterfaces OCTET STRING

MdlCmprEntry  
SEQUENCE    
  mdlCmprTypIdx Integer32
  mdlCmprCnfgIdx Integer32
  mdlCmprVersion Integer32
  mdlCmprSltIdx INTEGER
  mdlCmprObj OCTET STRING

MdlAlarmsCmprEntry  
SEQUENCE    
  mdlAlarmsCmprVersion Integer32
  mdlAlarmsCmprAlarmSlot Integer32
  mdlAlarmsCmprAlarmIdx Integer32
  mdlAlarmsCmprObj OCTET STRING

PrtSInstEntry  
SEQUENCE    
  prtSInstSltIdx INTEGER
  prtSInstPrtIdx Integer32
  prtSInstPrtType INTEGER
  prtSInstIfIndex Integer32
  prtSActiveStatus INTEGER
  prtSAlrStatus INTEGER
  prtSMaskedAlrStat INTEGER
  prtSClearAlrCmd INTEGER
  prtSTestMask Integer32
  prtSTstCmd INTEGER
  prtSTstDuration Integer32
  prtSBertClrCmd INTEGER
  prtSBertTstRslt Integer32
  prtSInterfaceType DisplayString
  prtSParamStatus OCTET STRING
  prtSTestMaskXp OCTET STRING
  prtSRdnStatus INTEGER

PrtSAlrEntry  
SEQUENCE    
  prtSAlrSltIdx INTEGER
  prtSAlrPrtIdx Integer32
  prtSAlrIdx Integer32
  prtSAlrCodeDescription DisplayString
  prtSAlrCode Integer32
  prtSAlrSeverity INTEGER
  prtSAlrState INTEGER
  prtSAlrCounter Integer32
  prtSAlrMask INTEGER
  prtSAlrInvert INTEGER
  prtSAlrCardType INTEGER

PrtFrStatisEntry  
SEQUENCE    
  prtFrStatisSltIdx INTEGER
  prtFrStatisPrtIdx INTEGER
  prtFrStatisInvIdx INTEGER
  prtFrTimeElapsed Integer32
  prtFrRxTotalFrames Counter32
  prtFrTxTotalFrames Counter32
  prtFrRxTotalBytes Counter32
  prtFrTxTotalBytes Counter32
  prtFrRxMngFrames Counter32
  prtFrTxMngFrames Counter32
  prtFrRxDeFrames Counter32
  prtFrTxDeFrames Counter32
  prtFrRxDcrdCongDeFr Counter32
  prtFrTxDcrdCongDeFr Counter32
  prtFrRxDcrdCongAllFr Counter32
  prtFrTxDcrdCongAllFr Counter32
  prtFrRxFecn Counter32
  prtFrTxFecn Counter32
  prtFrRxBecn Counter32
  prtFrTxBecn Counter32
  prtFrRxBeViol Counter32
  prtFrTxBeViol Counter32
  prtFrRxBcViol Counter32
  prtFrTxBcViol Counter32

PrtCrStatisEntry  
SEQUENCE    
  prtCrStatisSltIdx INTEGER
  prtCrStatisPrtIdx INTEGER
  prtCrStatisInvIdx INTEGER
  prtCrTimeElapsed Integer32
  prtCrRxTotalCells Counter32
  prtCrTxTotalCells Counter32
  prtCrRxDataCells Counter32
  prtCrTxDataCells Counter32

PrtDlciStatisEntry  
SEQUENCE    
  prtDlciSltIdx INTEGER
  prtDlciPrtIdx INTEGER
  prtDlciIdx Integer32
  prtDlciRxDeFrames Counter32
  prtDlciTxDeFrames Counter32
  prtDlciRxDcrdCongDeFr Counter32
  prtDlciTxDcrdCongDeFr Counter32
  prtDlciRxDcrdCongAllFr Counter32
  prtDlciTxDcrdCongAllFr Counter32
  prtDlciTxFecn Counter32
  prtDlciTxBecn Counter32
  prtDlciRxBeViol Counter32
  prtDlciTxBeViol Counter32
  prtDlciRxBcViol Counter32
  prtDlciTxBcViol Counter32

PrtT1FdlMsgEntry  
SEQUENCE    
  prtT1FdlMsgSltIdx INTEGER
  prtT1FdlMsgPrtIdx INTEGER
  prtT1FdlMsgFdlTxRx INTEGER
  prtT1FdlMsg OCTET STRING

PrtExTsSplitEntry  
SEQUENCE    
  prtExTsCnfgIdx Integer32
  prtExTsSltIdx INTEGER
  prtExTsPrtIdx Integer32
  prtExTsIdx Integer32
  prtExTsBit Integer32
  prtExTsIConSlot INTEGER
  prtExTsIConPrt Integer32
  prtExTsBitTest INTEGER
  prtExTsTxSignaling OCTET STRING
  prtExTsRxSignaling OCTET STRING
  prtExTsTxIoSignaling OCTET STRING
  prtExTsRxIoSignaling OCTET STRING

PrtAgendaBehaviourEntry  
SEQUENCE    
  prtAgendaBehaviourCnfgIdx Integer32
  prtAgendaBehaviourSltIdx Integer32
  prtAgendaBehaviourPrtIdx Integer32
  prtAgendaBehaviourOnOff INTEGER

PrtCnfgAgendaEntry  
SEQUENCE    
  prtCnfgAgendaCnfgIdx Integer32
  prtCnfgAgendaSltIdx Integer32
  prtCnfgAgendaPrtIdx Integer32
  prtCnfgAgendaDayIdx INTEGER
  prtCnfgAgendaSesId Integer32
  prtCnfgAgendaFrom Integer32
  prtCnfgAgendaTo Integer32

PrtGenCnfgEntry  
SEQUENCE    
  prtGenCnfgIdx Integer32
  prtGenCnfgSltIdx INTEGER
  prtGenCnfgPrtIdx Integer32
  prtGenCnfgLinkToSlot INTEGER
  prtGenCnfgLinkToPort Integer32
  prtGenCnfgPortId Integer32
  prtGenCnfgBusConnection INTEGER
  prtGenCnfgInbandMng INTEGER
  prtGenCnfgInbandMngRoutProt INTEGER
  prtGenCnfgProtectionMode INTEGER
  prtGenCnfgConnect INTEGER
  prtGenCnfgSignalingType INTEGER

PrtCmprEntry  
SEQUENCE    
  prtCmprTypIdx Integer32
  prtCmprCnfgIdx Integer32
  prtCmprVersion Integer32
  prtCmprSltIdx INTEGER
  prtCmprPrtIdx Integer32
  prtCmprObj OCTET STRING
  prtCmprStatisticObj OCTET STRING

PrtDlciCmprEntry  
SEQUENCE    
  prtDlciCmprCnfgIdx Integer32
  prtDlciCmprVersion Integer32
  prtDlciCmprSltIdx INTEGER
  prtDlciCmprPrtIdx INTEGER
  prtDlciCmprDlciIdx Integer32
  prtDlciCmprObj OCTET STRING

PrtAlarmsCmprEntry  
SEQUENCE    
  prtAlarmsCmprVersion Integer32
  prtAlarmsCmprAlarmSlot Integer32
  prtAlarmsCmprAlarmPort Integer32
  prtAlarmsCmprAlarmIdx Integer32
  prtAlarmsCmprObj OCTET STRING

PrtSExHsfStatEntry  
SEQUENCE    
  prtSExHsfSltIdx INTEGER
  prtSExHsfPrtIdx INTEGER
  prtSExHsfInterfaceTyp INTEGER
  prtSExHsfRts INTEGER

PrtIsdnStatusEntry  
SEQUENCE    
  prtIsdnStatusDspMode INTEGER
  prtIsdnStatusCallState INTEGER
  prtIsdnStatusCallingNumber DisplayString
  prtIsdnStatusCalledNumber DisplayString
  prtIsdnStatusCalledIP IpAddress
  prtIsdnStatusCallDirection INTEGER

MdlPbxFramerCnfgEntry  
SEQUENCE    
  mdlPbxFraCnfgIdx Integer32
  mdlPbxFraSltIdx INTEGER
  mdlPbxFraEnhEcho INTEGER
  mdlPbxFraTSGroupAss INTEGER
  mdlPbxFraSignalMode INTEGER
  mdlPbxFraSignalVector OCTET STRING
  mdlPbxFraSignalMask OCTET STRING
  mdlPbxFraFramerSlot INTEGER
  mdlPbxFraSignaling INTEGER
  mdlPbxFraTransSigTs Integer32

MdlProtIpEntry  
SEQUENCE    
  mdlProtIpCnfgIdx Integer32
  mdlProtIpSlotIdx INTEGER
  mdlProtIpAddress IpAddress
  mdlProtIpRowStatus RowStatus

MdlStatEntry  
SEQUENCE    
  mdlStatSltIdx INTEGER
  mdlStatHostIP IpAddress
  mdlStatHostMask IpAddress
  mdlStatDefaultGateway IpAddress

PrtExClCnfgEntry  
SEQUENCE    
  prtExClCnfgIdx Integer32
  prtExClSltIdx INTEGER
  prtExClPrtIdx INTEGER
  prtExClUsage INTEGER
  prtExClRate INTEGER
  prtExClDataBits INTEGER
  prtExClParity INTEGER
  prtExClStopBits INTEGER
  prtExClRoutingProtocol INTEGER
  prtExClEnabled INTEGER

PrtExPh1MlCnfgEntry  
SEQUENCE    
  prtExPh1MlCnfgIdx Integer32
  prtExPh1MlSltIdx INTEGER
  prtExPh1MlPrtIdx INTEGER
  prtExPh1MlConnect INTEGER
  prtExPh1MlLineType INTEGER
  prtExPh1MlLineCode INTEGER
  prtExPh1MlLineLen INTEGER
  prtExPh1MlRestoreTime INTEGER
  prtExPh1MlTxGain INTEGER
  prtExPh1MlRxSensitivity INTEGER
  prtExPh1MlIdleCode Integer32
  prtExPh1MlTdmTrunk INTEGER
  prtExPh1MlClkMode INTEGER
  prtExPh1MlMfClkSrcSlt INTEGER
  prtExPh1MlMfClkSrcPrt INTEGER
  prtExPh1MlFdlType INTEGER
  prtExPh1MlInbandMng INTEGER
  prtExPh1MlInbandMngRate INTEGER
  prtExPh1MlRedundType INTEGER
  prtExPh1MlRedundSlot INTEGER
  prtExPh1MlRedundPort INTEGER
  prtExPh1MlRedundRecTime Integer32
  prtExPh1MlInbandMngRoutProt INTEGER
  prtExPh1MlIfType INTEGER
  prtExPh1MlMultiplier INTEGER
  prtExPh1MlSupportedTS Integer32
  prtExPh1MlImpedance INTEGER
  prtExPh1MlQ50BwControl INTEGER
  prtExPh1MlQ50SignalPair INTEGER
  prtExPh1MlInternalSwitch INTEGER
  prtExPh1MlSigService INTEGER
  prtExPh1MlFragmentSize Integer32

PrtExPh1MlTsEntry  
SEQUENCE    
  prtExPh1MlTsCnfgIdx Integer32
  prtExPh1MlTsSltIdx INTEGER
  prtExPh1MlTsPrtIdx INTEGER
  prtExPh1MlTsIdx Integer32
  prtExPh1MlTsIConSlot INTEGER
  prtExPh1MlTsIConPrt Integer32
  prtExPh1MlTsIConTs Integer32
  prtExPh1MlTsExt OBJECT IDENTIFIER
  prtExPh1MlTsTest INTEGER
  prtExPh1MlTsType INTEGER
  prtExPh1MlTsBundle Integer32
  prtExPh1MlTsTestDuration Integer32
  prtExPh1MlTsSubChType INTEGER
  prtExPh1MlTsSubChMask Integer32
  prtExPh1MlTsChRate INTEGER
  prtExPh1MlTsByteReversal INTEGER
  prtExPh1MlTsSigProfile INTEGER

PrtInPh1MlCnfgEntry  
SEQUENCE    
  prtInPh1MlCnfgIdx Integer32
  prtInPh1MlSltType INTEGER
  prtInPh1MlPrtIdx Integer32
  prtInPh1MlConnect INTEGER
  prtInPh1MlRate INTEGER
  prtInPh1MlProtocol INTEGER
  prtInPh1MlConnectionTyp INTEGER
  prtInPh1MlCongResponse INTEGER
  prtInPh1MlCongLevel Integer32
  prtInPh1MlTc INTEGER
  prtInPh1MlFlowControl INTEGER
  prtInPh1MlSegment INTEGER
  prtInPh1MlFrMngProt INTEGER
  prtInPh1MlEnqPeriod Integer32
  prtInPh1MlFullRptPeriod Integer32
  prtInPh1MlFrWindowSize Integer32
  prtInPh1MlErrorsThreshold Integer32
  prtInPh1MlMaxIdleTime Integer32
  prtInPh1MlBearerCh INTEGER
  prtInPh1MlAssociatedExCh INTEGER
  prtInPh1MlClockEncoding INTEGER
  prtInPh1MlMinSeparators Integer32
  prtInPh1MlCcittCrc INTEGER
  prtInPh1MlFrameSeparator INTEGER

PrtInPh1MlDlciEntry  
SEQUENCE    
  prtInPh1MlDlciCnfgIdx Integer32
  prtInPh1MlDlciSltIdx INTEGER
  prtInPh1MlDlciPrtIdx INTEGER
  prtInPh1MlDlciIdx Integer32
  prtInPh1MlDlciValid INTEGER
  prtInPh1MlDlciIConSlt INTEGER
  prtInPh1MlDlciIConPrt INTEGER
  prtInPh1MlDlciIConDlci Integer32
  prtInPh1MlDlciTxBc INTEGER
  prtInPh1MlDlciTxBe INTEGER
  prtInPh1MlDlciRxBc INTEGER
  prtInPh1MlDlciRxBe INTEGER
  prtInPh1MlDlciPriority Integer32
  prtInPh1MlDlciStatus INTEGER

PrtPhMlCnfgEntry  
SEQUENCE    
  prtPhMlCnfgIdx Integer32
  prtPhMlSltIdx INTEGER
  prtPhMlPrtIdx INTEGER
  prtPhMlConnect INTEGER
  prtPhMlRate INTEGER
  prtPhMlCAS INTEGER
  prtPhMlClockMode INTEGER
  prtPhMlSatBuffer INTEGER
  prtPhMlDialProcess INTEGER
  prtPhMlSyncRestore Integer32
  prtPhMlBus INTEGER
  prtPhMlMfSyncSlot INTEGER
  prtPhMlClockSource INTEGER
  prtPhMlErrCorrection INTEGER
  prtPhMlCorrectionMode INTEGER
  prtPhMlControlSignals INTEGER
  prtPhMlInterfaceType INTEGER
  prtPhMlClockPolarity INTEGER

PrtLogicalCnfgEntry  
SEQUENCE    
  prtLogicalCnfgIdx Integer32
  prtLogicalSltIdx INTEGER
  prtLogicalPrtIdx Integer32
  prtLogicalConnect INTEGER
  prtLogicalFunction INTEGER
  prtLogicalRowStatus RowStatus

LinkSelectorCnfgEntry  
SEQUENCE    
  linkSelectorCnfgIdx Integer32
  linkSelectorSltIdx INTEGER
  linkSelectorPrtIdx Integer32
  linkSelectorMaxIdleTime Integer32
  linkSelectorMode INTEGER
  linkSelectorRevert INTEGER
  linkSelectorMinBUSession Integer32

LinkSelectorPLinkEntry  
SEQUENCE    
  pLinkCnfgIdx Integer32
  pLinkSltIdx INTEGER
  pLinkPrtIdx Integer32
  pLinkIdx Integer32
  pLinkSlotNu INTEGER
  pLinkPortNu Integer32
  pLinkPrioNu Integer32
  pLinkVRate INTEGER

PrtExPhPlCnfgEntry  
SEQUENCE    
  prtExPhPlCnfgIdx Integer32
  prtExPhPlSltIdx INTEGER
  prtExPhPlPrtIdx INTEGER
  prtExPhPlConnect INTEGER
  prtExPhPlHRate INTEGER
  prtExPhPlLRate INTEGER
  prtExPhPlProtocol INTEGER
  prtExPhPlConnectionTyp INTEGER
  prtExPhPlClkMode INTEGER
  prtExPhPlDceClkSrc INTEGER
  prtExPhPlCongResponse INTEGER
  prtExPhPlCongLevel Integer32
  prtExPhPlTc INTEGER
  prtExPhPlFlowControl INTEGER
  prtExPhPlDcdRts INTEGER
  prtExPhPlDcdRtsControlPath INTEGER
  prtExPhPlDataBits INTEGER
  prtExPhPlParity INTEGER
  prtExPhPlStopBits INTEGER
  prtExPhPlLXon Integer32
  prtExPhPlLXoff Integer32
  prtExPhPlFrMngProt INTEGER
  prtExPhPlEnqPeriod Integer32
  prtExPhPlFullRptPeriod Integer32
  prtExPhPlFrWindowSize Integer32
  prtExPhPlErrorsThreshold Integer32
  prtExPhPlPvcCreateMsg INTEGER
  prtExPhPlCllmMsg INTEGER
  prtExPhPlProtDelayLevel INTEGER
  prtExPhPlClockEncoding INTEGER
  prtExPhPlMinSeparators Integer32
  prtExPhPlCcittCrc INTEGER
  prtExPhPlFrameSeparator INTEGER
  prtExPhPlIdleCode Integer32
  prtExPhPlJitter Integer32

PrtExPhPlDlciEntry  
SEQUENCE    
  prtExPhPlDlciCnfgIdx Integer32
  prtExPhPlDlciSltIdx INTEGER
  prtExPhPlDlciPrtIdx INTEGER
  prtExPhPlDlciIdx Integer32
  prtExPhPlDlciValid INTEGER
  prtExPhPlDlciIConSlt INTEGER
  prtExPhPlDlciIConPrt INTEGER
  prtExPhPlDlciIConDlci Integer32
  prtExPhPlDlciTxBc INTEGER
  prtExPhPlDlciTxBe INTEGER
  prtExPhPlDlciRxBc INTEGER
  prtExPhPlDlciRxBe INTEGER
  prtExPhPlDlciPriority Integer32
  prtExPhPlDlciStatus INTEGER

PrtExPhPlModemEntry  
SEQUENCE    
  prtExPhPlModemCnfgIdx Integer32
  prtExPhPlModemSltIdx INTEGER
  prtExPhPlModemPrtIdx INTEGER
  prtExPhPlModemStatus INTEGER
  prtExPhPlModemActivate INTEGER
  prtExPhPlModemMaxIdleTime Integer32
  prtExPhPlModemTimeBtwnCalls Integer32
  prtExPhPlModemCallDelay Integer32

PrtExLs2CnfgEntry  
SEQUENCE    
  prtExLs2CnfgIdx Integer32
  prtExLs2SltIdx INTEGER
  prtExLs2PrtIdx INTEGER
  prtExLs2Connect INTEGER
  prtExLs2Rate INTEGER
  prtExLs2ClkMode INTEGER
  prtExLs2Cts INTEGER
  prtExLs2Dcd INTEGER
  prtExLs2EnvIdx Integer32

PrtInLs2CnfgEntry  
SEQUENCE    
  prtInLs2CnfgIdx Integer32
  prtInLs2SltIdx INTEGER
  prtInLs2PrtIdx INTEGER
  prtInLs2Connect INTEGER
  prtInLs2Group Integer32
  prtInLs2Member Integer32
  prtInLs2LinkTo INTEGER
  prtInLs2EnvAssign INTEGER

PrtVc2CnfgEntry  
SEQUENCE    
  prtVc2CnfgIdx Integer32
  prtVc2SltIdx INTEGER
  prtVc2PrtIdx Integer32
  prtExVc2Connect INTEGER
  prtExVc2TransGain Integer32
  prtExVc2ReceiveGain Integer32
  prtExVc2Wire INTEGER
  prtExVc2CodingLaw INTEGER
  prtExVc2Sig INTEGER
  prtExVc2Oos INTEGER
  prtExVc2LinkTo INTEGER
  prtExVc2OperMode INTEGER
  prtExVc2SigProfile INTEGER
  prtExVc2CallEnable INTEGER
  prtExVc2R2Delay INTEGER
  prtExVc2CasStd INTEGER
  prtExVc2EchoCanceler INTEGER
  prtExVc2IfType INTEGER
  prtExVc2Encoding INTEGER
  prtExVc2TxBitCode OCTET STRING
  prtExVc2RxBitOutput OCTET STRING
  prtExVc2MeterRate INTEGER
  prtExVc2IfSignaling INTEGER
  prtExVc2SeizeAck INTEGER
  prtExVc2EandMType INTEGER
  prtExVc2RemType INTEGER
  prtExVc2ConvTime INTEGER
  prtExVc2SigFeedback INTEGER
  prtExVc2EchoCancelerModule INTEGER
  prtExVc2ReversePolarity INTEGER
  prtExVc2RingerFrequency INTEGER
  prtExVc2SigService INTEGER
  prtExVc2CallerIdEnable INTEGER
  prtExVc2CompressMethod INTEGER
  prtExVc2ObMode INTEGER
  prtExVc2VAD INTEGER
  prtExVc2NoiseLevelForVAD INTEGER
  prtExVc2WesternSigMode INTEGER
  prtExVc2BusProtectionPoint INTEGER
  prtExVc2ImpedanceStandard INTEGER

PrtHsfCnfgEntry  
SEQUENCE    
  prtHsfCnfgIdx Integer32
  prtHsfSltIdx INTEGER
  prtHsfPrtIdx INTEGER
  prtExHsfConnect INTEGER
  prtExHsfRate INTEGER
  prtExHsfClkMode INTEGER
  prtExHsfCts INTEGER
  prtExHsfFifoSize INTEGER
  prtExHsfLinkTo INTEGER
  prtExHsfOperMode INTEGER
  prtExHsfInbandLoopback INTEGER
  prtExHsfClkPolarity INTEGER
  prtExHsfControlSignal INTEGER
  prtExHsfBcastRingSrcPort INTEGER

PrtExHs4CnfgEntry  
SEQUENCE    
  prtExHs4CnfgIdx Integer32
  prtExHs4SltIdx INTEGER
  prtExHs4PrtIdx INTEGER
  prtExHs4Connect INTEGER
  prtExHs4LineType INTEGER
  prtExHs4LineCode INTEGER
  prtExHs4LineLen INTEGER
  prtExHs4RestoreT INTEGER
  prtExHs4OosSig INTEGER
  prtExHs4OosCode INTEGER
  prtExHs4IdleCode Integer32
  prtExHs4MfClkSrcSlt INTEGER
  prtExHs4MfClkSrcPrt INTEGER

PrtExHs4TsEntry  
SEQUENCE    
  prtExHs4TsCnfgIdx Integer32
  prtExHs4TsSltIdx INTEGER
  prtExHs4TsPrtIdx INTEGER
  prtExHs4TsIdx Integer32
  prtExHs4TsIConSlot INTEGER
  prtExHs4TsIConPrt INTEGER
  prtExHs4TsIConTs Integer32

PrtExHsiCnfgEntry  
SEQUENCE    
  prtExHsiCnfgIdx Integer32
  prtExHsiSltIdx INTEGER
  prtExHsiPrtIdx Integer32
  prtExHsiConnect INTEGER
  prtExHsiRate INTEGER
  prtExHsiLinkTo INTEGER
  prtExHsiInterface INTEGER
  prtExHsiActType INTEGER

PrtInHsiCnfgEntry  
SEQUENCE    
  prtInHsiCnfgIdx Integer32
  prtInHsiSltIdx INTEGER
  prtInHsiPrtIdx Integer32
  prtInHsiConnect INTEGER
  prtInHsiRate INTEGER
  prtInHsiConcentratedTo Integer32

PrtExHsrCnfgEntry  
SEQUENCE    
  prtExHsrCnfgIdx Integer32
  prtExHsrSltIdx INTEGER
  prtExHsrPrtIdx Integer32
  prtExHsrConnect INTEGER
  prtExHsrProtocol INTEGER
  prtExHsrRate INTEGER
  prtExHsrDataBits INTEGER
  prtExHsrParity INTEGER
  prtExHsrStopBits INTEGER
  prtExHsrCts INTEGER
  prtExHsrClkMode INTEGER
  prtExHsrLinkTo INTEGER
  prtExHsrDcdDsr INTEGER
  prtExHsrOperMode INTEGER
  prtExHsrRtsDtr INTEGER
  prtExHsrLlbEnable INTEGER
  prtExHsrRlbEnable INTEGER
  prtExHsrRateAdapt INTEGER
  prtExHsrRemoteModem INTEGER
  prtExHsrEncapsMode INTEGER

PrtExMbeCnfgEntry  
SEQUENCE    
  prtExMbeCnfgIdx Integer32
  prtExMbeSltIdx INTEGER
  prtExMbePrtIdx INTEGER
  prtExMbeLan INTEGER

PrtInMbeCnfgEntry  
SEQUENCE    
  prtInMbeCnfgIdx Integer32
  prtInMbeSltIdx INTEGER
  prtInMbePrtIdx INTEGER
  prtInMbeConnect INTEGER
  prtInMbeRate INTEGER
  prtInMbeLinkTo INTEGER

PrtExTreCnfgEntry  
SEQUENCE    
  prtExTreCnfgIdx Integer32
  prtExTreSltIdx INTEGER
  prtExTrePrtIdx INTEGER
  prtExTreLan INTEGER
  prtExTreLanRate INTEGER

PrtInTreCnfgEntry  
SEQUENCE    
  prtInTreCnfgIdx Integer32
  prtInTreSltIdx INTEGER
  prtInTrePrtIdx INTEGER
  prtInTreConnect INTEGER
  prtInTreRate INTEGER
  prtInTreLinkTo INTEGER

PrtExPVc4CnfgEntry  
SEQUENCE    
  prtExPVc4CnfgIdx Integer32
  prtExPVc4SltIdx INTEGER
  prtExPVc4PrtIdx INTEGER
  prtExPVc4PrtType INTEGER
  prtExPVc4Connect INTEGER
  prtExPVc4IfType INTEGER
  prtExPVc4TxGain Integer32
  prtExPVc4RxGain Integer32
  prtExPVc4MaxRate INTEGER
  prtExPVc4Tc INTEGER
  prtExPVc4Oos INTEGER
  prtExPVc4EchoCanceler INTEGER
  prtExPVc4VarDelay Integer32
  prtExPVc4CongLevel Integer32
  prtExPVc4Wire INTEGER
  prtExPVc4ExtensionType INTEGER
  prtExPVc4ExtensionNumber DisplayString
  prtExPVc4OutPulsing INTEGER
  prtExPVc4HuntGroupMb INTEGER
  prtExPVc4HuntGroupIdx Integer32
  prtExPVc4AutoFaxMode INTEGER
  prtExPVc4FaxRate INTEGER
  prtExPVc4SeizeAck INTEGER
  prtExPVc4SignalingProtocol INTEGER
  prtExPVc4DelayStart Integer32
  prtExPVc4WinkMinDuration Integer32
  prtExPVc4WinkMaxDuration Integer32
  prtExPVc4GenerateTone INTEGER
  prtExPVc4CodingLaw INTEGER
  prtExPVc4GenerateRingBack INTEGER
  prtExPVc4ChannelId Integer32
  prtExPVc4PortConnection INTEGER
  prtExPVc4CoderAndRate INTEGER
  prtExPVc4DestinationNum DisplayString
  prtExPVc4DtmfRelay INTEGER
  prtExPVc4DiscOnSilence Integer32
  prtExPVc4DynamicJitter INTEGER
  prtExPVc4EandMType INTEGER
  prtExPVc4Rate Integer32
  prtExPVc4FrameSize Integer32
  prtExPVc4MultiplexInterval Integer32
  prtExPVc4TransportProtocol INTEGER
  prtExPVc4MultiFreqRelay INTEGER
  prtExPVc4MinPulseWidth Integer32
  prtExPVc4MinPowerLevel Integer32
  prtExPVc4SuperTandem INTEGER
  prtExPVc4DestIp IpAddress
  prtExPVc4DestBundle Integer32
  prtExPVc4SrcIpAddress IpAddress
  prtExPVc4SrcIpMask IpAddress
  prtExPVc4DefaultGateway IpAddress
  prtExPVc4SigPacketInterval Unsigned32

PrtExPVc4DlciEntry  
SEQUENCE    
  prtExPVc4DlciCnfgIdx Integer32
  prtExPVc4DlciSltIdx INTEGER
  prtExPVc4DlciPrtIdx INTEGER
  prtExPVc4DlciValid INTEGER
  prtExPVc4DlciIConSlt INTEGER
  prtExPVc4DlciIConPrt INTEGER
  prtExPVc4DlciIConDlci Integer32
  prtExPVc4DlciTxBc INTEGER
  prtExPVc4DlciTxBe INTEGER
  prtExPVc4DlciRxBc INTEGER
  prtExPVc4DlciRxBe INTEGER
  prtExPVc4DlciPriority Integer32
  prtExPVc4DlciStatus INTEGER

PrtExLs6CnfgEntry  
SEQUENCE    
  prtExLs6CnfgIdx Integer32
  prtExLs6SltIdx INTEGER
  prtExLs6PrtIdx INTEGER
  prtExLs6Connect INTEGER
  prtExLs6Protocol INTEGER
  prtExLs6Rate INTEGER
  prtExLs6ClkMode INTEGER
  prtExLs6CtrlSignal INTEGER
  prtExLs6DataBits INTEGER
  prtExLs6Cts INTEGER
  prtExLs6LinkToInternal INTEGER

PrtExLs6VCnfgEntry  
SEQUENCE    
  prtExLs6VCnfgIdx Integer32
  prtExLs6VSltIdx INTEGER
  prtExLs6VPrtIdx INTEGER
  prtExLs6VConnect INTEGER
  prtExLs6VRate INTEGER
  prtExLs6VEchoCanceler INTEGER
  prtExLs6VIfType INTEGER
  prtExLs6VTxGain Integer32
  prtExLs6VRxGain Integer32
  prtExLs6VOos INTEGER

PrtInLs6CnfgEntry  
SEQUENCE    
  prtInLs6CnfgIdx Integer32
  prtInLs6SltIdx INTEGER
  prtInLs6PrtIdx INTEGER
  prtInLs6Connect INTEGER
  prtInLs6TandemMode INTEGER
  prtInLs6Rate INTEGER
  prtInLs6RemoteType INTEGER
  prtInLs6LinkTo INTEGER

PrtExVc3CnfgEntry  
SEQUENCE    
  prtExVc3CnfgIdx Integer32
  prtExVc3SltIdx INTEGER
  prtExVc3PrtIdx INTEGER
  prtExVc3Connect INTEGER
  prtExVc3TransGain Integer32
  prtExVc3ReceiveGain Integer32
  prtExVc3Wire INTEGER
  prtExVc3Rate INTEGER
  prtExVc3EchoCanceler INTEGER

PrtInVc3CnfgEntry  
SEQUENCE    
  prtInVc3CnfgIdx Integer32
  prtInVc3SltIdx INTEGER
  prtInVc3PrtIdx INTEGER
  prtInVc3Connect INTEGER
  prtInVc3Rate INTEGER
  prtInVc3Oos INTEGER
  prtInVc3LinkTo INTEGER

PrtExVcPbxCnfgEntry  
SEQUENCE    
  prtExVcPbxCnfgIdx Integer32
  prtExVcPbxSltIdx INTEGER
  prtExVcPbxPrtIdx INTEGER
  prtExVcPbxConnect INTEGER
  prtExVcPbxGroup INTEGER
  prtExVcPbxTransparent INTEGER
  prtExVcPbxTransSignalTs Integer32
  prtExVcPbxFrame INTEGER
  prtExVcPbxRestoreTime INTEGER
  prtExVcPbxLineCode INTEGER
  prtExVcPbxLineLength INTEGER
  prtExVcPbxLinkTo INTEGER
  prtExVcPbxSignalOper INTEGER
  prtExVcPbxIdleCode INTEGER

PrtIn1p6VcPbxCnfgEntry  
SEQUENCE    
  prtIn1p6VcPbxCnfgIdx Integer32
  prtIn1p6VcPbxSltIdx INTEGER
  prtIn1p6VcPbxPrtIdx INTEGER
  prtIn1p6VcPbxConnect INTEGER
  prtIn1p6VcPbxRate INTEGER
  prtIn1p6VcPbxEchoCanceler INTEGER
  prtIn1p6VcPbxPabxTs Integer32

PrtIn7p8VcPbxCnfgEntry  
SEQUENCE    
  prtIn7p8VcPbxCnfgIdx Integer32
  prtIn7p8VcPbxSltIdx INTEGER
  prtIn7p8VcPbxPrtIdx INTEGER
  prtIn7p8VcPbxConnect INTEGER
  prtIn7p8VcPbxMode INTEGER
  prtIn7p8VcPbxRate INTEGER
  prtIn7p8VcPbxSignalMode INTEGER
  prtIn7p8VcPbxOos INTEGER
  prtIn7p8VcPbxLinkTo INTEGER

PrtExVcPbxTsEntry  
SEQUENCE    
  prtExVcPbxTsCnfgIdx Integer32
  prtExVcPbxTsSltIdx INTEGER
  prtExVcPbxTsPrtIdx INTEGER
  prtExVcPbxTsIdx Integer32
  prtExVcPbxTsMode INTEGER
  prtExVcPbxTsIConSlot INTEGER
  prtExVcPbxTsIConPrt INTEGER
  prtExVcPbxTsIConTs Integer32
  prtExVcPbxTsRemPrt INTEGER
  prtExVcPbxTsRemTs Integer32
  prtExVcPbxTsRemConnID Unsigned32
  prtExVcPbxTsSourceSlot INTEGER
  prtExVcPbxTsSourcePrt Unsigned32

PrtIsdnCnfgEntry  
SEQUENCE    
  prtIsdnCnfgIdx Integer32
  prtIsdnSltIdx INTEGER
  prtIsdnPrtIdx Integer32
  prtIsdnConnect INTEGER
  prtIsdnSignalingProtocol INTEGER
  prtIsdnBasicRateLineTopology INTEGER
  prtIsdnMode INTEGER
  prtIsdnFilter INTEGER
  prtIsdnSimultaneousCall INTEGER
  prtIsdnNumOfAbstractTerm Integer32
  prtIsdnSwitchMode INTEGER
  prtIsdnAbSide INTEGER
  prtIsdnQsigRole INTEGER
  prtIsdnInterface INTEGER
  prtIsdnCallMode INTEGER
  prtIsdnCallBackTimeout Integer32

PrtIsdnEndpointEntry  
SEQUENCE    
  prtIsdnEndpointCnfgIdx Integer32
  prtIsdnEndpointSltIdx INTEGER
  prtIsdnEndpointPrtIdx Integer32
  prtIsdnEndpointIdx INTEGER
  prtIsdnEndpointTeiType INTEGER
  prtIsdnEndpointTeiValue Integer32
  prtIsdnEndpointSpid DisplayString
  prtIsdnEndpointBearerCh INTEGER
  prtIsdnEndpointRowStatus RowStatus

PrtIsdnDirectoryEntry  
SEQUENCE    
  prtIsdnDirectoryCnfgIdx Integer32
  prtIsdnDirectorySltIdx INTEGER
  prtIsdnDirectoryPrtIdx Integer32
  prtIsdnDirectoryLocalAddr DisplayString
  prtIsdnDirectoryLocalSubAddr DisplayString
  prtIsdnDirectoryRemoteAddr DisplayString
  prtIsdnDirectoryRemoteSubAddr DisplayString
  prtIsdnDirectoryPrtNu Integer32
  prtIsdnDirectoryTeiId Integer32
  prtIsdnDirectoryRowStatus RowStatus
  prtIsdnDirectoryLocalAddr2 DisplayString
  prtIsdnDirectoryLocalSubAddr2 DisplayString
  prtIsdnDirectoryRemoteAddr2 DisplayString
  prtIsdnDirectoryRemoteSubAddr2 DisplayString

PrtFrPlusCnfgEntry  
SEQUENCE    
  prtFrPlusCnfgIdx Integer32
  prtFrPlusSltIdx INTEGER
  prtFrPlusPrtIdx Integer32
  prtFrPlusNotSegmentedPriorities OCTET STRING

PrtMl4CnfgEntry  
SEQUENCE    
  prtMl4CnfgIdx Integer32
  prtMl4SltIdx INTEGER
  prtMl4PrtIdx INTEGER
  prtMl4SigProfile INTEGER
  prtMl4CGA INTEGER
  prtMl4Oos INTEGER
  prtMl4VoiceOos OCTET STRING
  prtMl4DataOos OCTET STRING
  prtMl4Service INTEGER
  prtMl4IpAddress IpAddress
  prtMl4IpMask IpAddress
  prtMl4SignalingMode INTEGER
  prtMl4EchoCanceler INTEGER
  prtMl4OosErrorSource INTEGER
  prtMl4OosEntryThreshold Integer32
  prtMl4OosExitThreshold Integer32
  prtMl4LogicalLinkId Integer32
  prtMl4DedicatedTs Integer32
  prtMl4RemCrc INTEGER
  prtMl4CrossConnectLevel INTEGER
  prtMl4PppEchoFailDetection INTEGER

PrtAcmCnfgEntry  
SEQUENCE    
  prtAcmCnfgIdx Integer32
  prtAcmSltIdx INTEGER
  prtAcmPrtIdx INTEGER
  prtAcmConnect INTEGER
  prtAcmActiveState INTEGER
  prtAcmAlrString DisplayString

PrtE2CnfgEntry  
SEQUENCE    
  prtE2CnfgIdx Integer32
  prtE2SltIdx INTEGER
  prtE2PrtIdx INTEGER
  prtE2Connect INTEGER
  prtE2MngOnNationalBit INTEGER

PrtLanWanCnfgEntry  
SEQUENCE    
  prtLanWanCnfgIdx Integer32
  prtLanWanSltIdx INTEGER
  prtLanWanPrtIdx Integer32
  prtLanWanMode INTEGER
  prtLanWanDestIf Integer32
  prtLanWanEgressVlanMode INTEGER
  prtLanWanL2Protocol INTEGER
  prtLanWanStpPriority Integer32
  prtLanWanStpCost Integer32
  prtLanWanToLanVlanMode INTEGER
  prtLanWanVlanId Integer32
  prtLanWanVlanPriority Integer32
  prtLanWanMtu Integer32
  prtLanWanVlanType INTEGER

Dsx1XCurrentEntry  
SEQUENCE    
  dsx1CurrentLOS PerfCurrentCount
  dsx1CurrentLOF PerfCurrentCount
  dsx1CurrentLOC PerfCurrentCount
  dsx1CurrentAIS PerfCurrentCount
  dsx1CurrentRAI PerfCurrentCount
  dsx1CurrentLOMF PerfCurrentCount
  dsx1CurrentFEBE PerfCurrentCount
  dsx1CurrentStatus OCTET STRING
  dsx1CurrentBPV PerfCurrentCount
  dsx1CurrentLOCRCMF PerfCurrentCount
  dsx1CurrentLOFC PerfCurrentCount
  dsx1CurrentCRCErrors PerfCurrentCount

Dsx1XIntervalEntry  
SEQUENCE    
  dsx1IntervalLOS PerfIntervalCount
  dsx1IntervalLOF PerfIntervalCount
  dsx1IntervalLOC PerfIntervalCount
  dsx1IntervalAIS PerfIntervalCount
  dsx1IntervalRAI PerfIntervalCount
  dsx1IntervalLOMF PerfIntervalCount
  dsx1IntervalFEBE PerfIntervalCount
  dsx1IntervalStatus OCTET STRING
  dsx1IntervalBPV PerfIntervalCount
  dsx1IntervalLOCRCMF PerfIntervalCount
  dsx1IntervalLOFC PerfIntervalCount

Dsx1XTotalEntry  
SEQUENCE    
  dsx1TotalLOS PerfTotalCount
  dsx1TotalBPV PerfTotalCount
  dsx1TotalLOFC PerfTotalCount

Dsx1DataStreamStatEntry  
SEQUENCE    
  dsx1DataStreamStatIfIndex Integer32
  dsx1DataStreamStatIndex Integer32
  dsx1DataStreamStatValid TruthValue
  dsx1DataStreamStatInFrames Counter32
  dsx1DataStreamStatInBytes Counter32
  dsx1DataStreamStatInDiscards Counter32
  dsx1DataStreamStatInErrors Counter32
  dsx1DataStreamStatOutFrames Counter32
  dsx1DataStreamStatOutBytes Counter32
  dsx1DataStreamStatOutDiscards Counter32
  dsx1DataStreamStatOutErrors Counter32

Dsx1XConfigEntry  
SEQUENCE    
  dsx1IdleCode Integer32
  dsx1LineMode INTEGER
  dsx1dBTxGain INTEGER
  dsx1RxSensitivity INTEGER
  dsx1RestoreTime INTEGER
  dsx1TcFirstSignal Integer32
  dsx1TcSignal Integer32
  dsx1TcPattern Integer32
  dsx1Scramble INTEGER
  dsx1LineAdaptiveTimingMode INTEGER
  dsx1TxClockSource INTEGER
  dsx1AisEnable INTEGER
  dsx1TsEchoCancel OCTET STRING
  dsx1EchoCancelerModule INTEGER
  dsx1PortFunction INTEGER
  dsx1PortMultiplier INTEGER
  dsx1LeasedLine INTEGER
  dsx1CsuLoop INTEGER
  dsx1ClockSource Integer32
  dsx1OosSignal INTEGER
  dsx1BundleNextIndex Integer32
  dsx1CRC6CalcMode INTEGER
  dsx1SendUponFail INTEGER

PrtDs3IfEntry  
SEQUENCE    
  prtDs3IfTimeElapsed Integer32
  prtDs3IfValidIntervals Integer32

PrtDs3CurrentEntry  
SEQUENCE    
  prtDs3CurrentLOS Gauge32
  prtDs3CurrentOOF Gauge32
  prtDs3CurrentLOC Gauge32
  prtDs3CurrentAIS Gauge32
  prtDs3CurrentRDI Gauge32
  prtDs3CurrentUAS Gauge32
  prtDs3CurrentBIP Gauge32
  prtDs3CurrentFEBE Gauge32
  prtDs3CurrentSLM Gauge32
  prtDs3CurrentSES Gauge32
  prtDs3CurrentES Gauge32
  prtDs3CurrentBitParity Gauge32
  prtDs3CurrentPlcpLOF Gauge32
  prtDs3CurrentPlcpRAI Gauge32
  prtDs3CurrentPlcpBIP Gauge32
  prtDs3CurrentPlcpFEBE Gauge32
  prtDs3CurrentBPV Gauge32
  prtDs3CurrentLCE Gauge32
  prtDs3CurrentStatus OCTET STRING

PrtDs3IntervalEntry  
SEQUENCE    
  prtDs3IntervalNumber Integer32
  prtDs3IntervalLOS Gauge32
  prtDs3IntervalOOF Gauge32
  prtDs3IntervalLOC Gauge32
  prtDs3IntervalAIS Gauge32
  prtDs3IntervalRDI Gauge32
  prtDs3IntervalUAS Gauge32
  prtDs3IntervalBIP Gauge32
  prtDs3IntervalFEBE Gauge32
  prtDs3IntervalSLM Gauge32
  prtDs3IntervalSES Gauge32
  prtDs3IntervalES Gauge32
  prtDs3IntervalBitParity Gauge32
  prtDs3IntervalPlcpLOF Gauge32
  prtDs3IntervalPlcpRAI Gauge32
  prtDs3IntervalPlcpBIP Gauge32
  prtDs3IntervalPlcpFEBE Gauge32
  prtDs3IntervalBPV Gauge32
  prtDs3IntervalLCE Gauge32
  prtDs3IntervalStatus OCTET STRING

PrtDs3TotalEntry  
SEQUENCE    
  prtDs3TotalUAS Gauge32
  prtDs3TotalBPV Gauge32
  prtDs3TotalLCE Gauge32
  prtDs3TotalSES Gauge32

Dsx3XConfigEntry  
SEQUENCE    
  dsx3AisEnable INTEGER
  dsx3TxClockSource INTEGER

Dsx3MappingEntry  
SEQUENCE    
  dsx3MappingDs3Index InterfaceIndex
  dsx3MappingNumber Unsigned32
  dsx3MappingIfIndex InterfaceIndex

AtmNteConfIfEntry  
SEQUENCE    
  atmConfIfTransmitClk INTEGER
  atmConfIfLoopback INTEGER
  atmConfIfFrameType INTEGER
  atmConfIfCardType INTEGER
  atmConfAtmIfVpiVciLimit INTEGER
  atmConfIfHwFeatures INTEGER
  atmConfIfOutputRate Integer32
  atmConfIfInputRate Integer32
  atmConfAlarmForwarding INTEGER
  atmConfIfAllocatedBw Integer32
  atmConfIfLowerVpi Integer32
  atmConfIfOamMode INTEGER
  atmConfIfOamFailureInd INTEGER

AtmNteAlarmIfEntry  
SEQUENCE    
  atmInterfaceActiveAlarms Integer32
  atmThresholdSectionBIP Integer32
  atmThresholdLineBIP Integer32
  atmThresholdLineFEBE Integer32
  atmThresholdPathBIP Integer32
  atmThresholdPathFEBE Integer32
  atmThresholdErroredCells Integer32
  atmThresholdLostCells Integer32
  atmThresholdMisinsertedCells Integer32
  atmInterfaceAlarmStatus INTEGER
  atmInterfaceMaskAlarms Integer32

AtmNteConfVpEntry  
SEQUENCE    
  atmConfVpPolicing INTEGER
  atmConfVpCCAdminStatus INTEGER
  atmConfVpLoopbackAdminStatus INTEGER
  atmConfVpLoopbackSinkAddress OCTET STRING
  atmConfVpCongestionControl OCTET STRING
  atmConfVpCCDirection INTEGER
  atmConfVpCreationTime DateAndTime
  atmConfVpOamSupport INTEGER
  atmConfVpCCOperStatus INTEGER
  atmConfVpLoopbackTraffic INTEGER
  atmConfVpLoopbackFailureInd INTEGER
  atmConfVpLoopbackFailureThreshold Integer32
  atmConfVpOamDirection INTEGER
  atmConfVpOamDescrIndex Integer32
  atmConfVpConnected INTEGER

AtmNteAlarmVpEntry  
SEQUENCE    
  atmNteVpAlarmVpi Integer32
  atmNteVpActiveAlarms Integer32

AtmNteAlarmVcEntry  
SEQUENCE    
  atmNteVcAlarmVpi Integer32
  atmNteVcAlarmVci Integer32
  atmNteVcActiveAlarms Integer32

AtmIfDataEntry  
SEQUENCE    
  atmIfTimeElapsed Integer32
  atmIfValidIntervals Integer32
  atmIfTxCells Counter32
  atmIfRxCells Counter32
  atmIfUncorrectedHecs Counter32

AtmIfCurrentEntry  
SEQUENCE    
  atmIfCurrentTxCells Gauge32
  atmIfCurrentRxCells Gauge32
  atmIfCurrentCorrectedHecs Gauge32
  atmIfCurrentUncorrectedHecs Gauge32
  atmIfCurrentHecErrorSeconds Gauge32

AtmIfIntervalEntry  
SEQUENCE    
  atmIfIntervalNumber Integer32
  atmIfIntervalTxCells Gauge32
  atmIfIntervalRxCells Gauge32
  atmIfIntervalCorrectedHecs Gauge32
  atmIfIntervalUncorrectedHecs Gauge32
  atmIfIntervalHecErrorSeconds Gauge32

AtmVpCurrentEntry  
SEQUENCE    
  atmVpCurrentVpi Integer32
  atmVpCurrentRxCellsClp01 Gauge32
  atmVpCurrentRxCellsClp0 Gauge32
  atmVpCurrentGcra0Violations Gauge32
  atmVpCurrentGcra1Violations Gauge32
  atmVpCurrentRxAIS Gauge32
  atmVpCurrentTxAIS Gauge32
  atmVpCurrentRxRDI Gauge32
  atmVpCurrentTxRDI Gauge32
  atmVpCurrentContinuityLoss Gauge32
  atmVpCurrentUAS Gauge32
  atmVpCurrentSES Gauge32
  atmVpCurrentCDC Gauge32
  atmVpCurrentTotalDiscards Gauge32
  atmVpCurrentClp0Discards Gauge32
  atmVpCurrentTotalCellOuts Gauge32
  atmVpCurrentClp0CellOuts Gauge32
  atmVpCurrentTaggedOuts Gauge32
  atmVpCurrentPCR Gauge32
  atmVpCurrentSCR Gauge32
  atmVpCurrentMCR Gauge32
  atmVpCurrentShaperTotalDiscards Gauge32
  atmVpCurrentShaperClp0Discards Gauge32
  atmVpCurrentShaperClp1Discards Gauge32

AtmVpPMCurrentEntry  
SEQUENCE    
  atmVpPMCurrentDir INTEGER
  atmVpPMCurrentVpi Integer32
  atmVpPMCurrentTxClp01 Gauge32
  atmVpPMCurrentTxClp0 Gauge32
  atmVpPMCurrentRxClp01 Gauge32
  atmVpPMCurrentRxClp0 Gauge32
  atmVpPMCurrentErroredCells Gauge32
  atmVpPMCurrentLostCells Gauge32
  atmVpPMCurrentMisinsertedCells Gauge32
  atmVpPMCurrentECB Gauge32
  atmVpPMCurrentSECB Gauge32
  atmVpPMCurrentES Gauge32
  atmVpPMCurrentSES Gauge32
  atmVpPMCurrentUAS Gauge32
  atmVpPMCurrentIntervalQuality INTEGER
  atmVpPMCurrentLastDayQuality INTEGER

AtmVpIntervalEntry  
SEQUENCE    
  atmVpIntervalVpi Integer32
  atmVpIntervalNumber Integer32
  atmVpIntervalRxCellsClp01 Gauge32
  atmVpIntervalRxCellsClp0 Gauge32
  atmVpIntervalGcra0Violations Gauge32
  atmVpIntervalGcra1Violations Gauge32
  atmVpIntervalRxAIS Gauge32
  atmVpIntervalTxAIS Gauge32
  atmVpIntervalRxRDI Gauge32
  atmVpIntervalTxRDI Gauge32
  atmVpIntervalContinuityLoss Gauge32
  atmVpIntervalUAS Gauge32
  atmVpIntervalSES Gauge32
  atmVpIntervalCDC Gauge32
  atmVpIntervalTotalDiscards Gauge32
  atmVpIntervalClp0Discards Gauge32
  atmVpIntervalTotalCellOuts Gauge32
  atmVpIntervalClp0CellOuts Gauge32
  atmVpIntervalTaggedOuts Gauge32
  atmVpIntervalPCR Gauge32
  atmVpIntervalSCR Gauge32
  atmVpIntervalMCR Gauge32
  atmVpIntervalShaperTotalDiscards Gauge32
  atmVpIntervalShaperClp0Discards Gauge32
  atmVpIntervalShaperClp1Discards Gauge32

AtmVpPMIntervalEntry  
SEQUENCE    
  atmVpPMIntervalVpi Integer32
  atmVpPMIntervalDir INTEGER
  atmVpPMIntervalNumber Integer32
  atmVpPMIntervalTxClp01 Gauge32
  atmVpPMIntervalTxClp0 Gauge32
  atmVpPMIntervalRxClp01 Gauge32
  atmVpPMIntervalRxClp0 Gauge32
  atmVpPMIntervalErroredCells Gauge32
  atmVpPMIntervalLostCells Gauge32
  atmVpPMIntervalMisinsertedCells Gauge32
  atmVpPMIntervalECB Gauge32
  atmVpPMIntervalSECB Gauge32
  atmVpPMIntervalES Gauge32
  atmVpPMIntervalSES Gauge32
  atmVpPMIntervalUAS Gauge32
  atmVpPMIntervalQuality INTEGER
  atmVpPMIntervalLastDayQuality INTEGER

AtmVpQoSEntry  
SEQUENCE    
  atmVpQoSPeriodRef INTEGER
  atmVpQoSElapsedTime Integer32
  atmVpQoSUAS Gauge32

AtmVpPMQoSEntry  
SEQUENCE    
  atmVpPMQoSDirection INTEGER
  atmVpPMQoSPeriodRef INTEGER
  atmVpPMQoSCLR Gauge32
  atmVpPMQoSCER Gauge32
  atmVpPMQoSCMR Gauge32

AtmVpShaperStatEntry  
SEQUENCE    
  atmVpShaperDiscarded Counter32
  atmVpShaperOccupation Integer32
  atmVpShaperMaxOccupation Integer32
  atmVpShaperLevel INTEGER
  atmVpShaperEpdDropped Counter32
  atmVpShaperTotalEpdDropped Counter32

AtmVcCurrentEntry  
SEQUENCE    
  atmVcCurrentVpi Integer32
  atmVcCurrentVci Integer32
  atmVcCurrentRxCellsClp01 Gauge32
  atmVcCurrentRxCellsClp0 Gauge32
  atmVcCurrentGcra0Violations Gauge32
  atmVcCurrentGcra1Violations Gauge32
  atmVcCurrentRxAIS Gauge32
  atmVcCurrentTxAIS Gauge32
  atmVcCurrentRxRDI Gauge32
  atmVcCurrentTxRDI Gauge32
  atmVcCurrentContinuityLoss Gauge32
  atmVcCurrentUAS Gauge32
  atmVcCurrentSES Gauge32
  atmVcCurrentCDC Gauge32
  atmVcCurrentTotalDiscards Gauge32
  atmVcCurrentClp0Discards Gauge32
  atmVcCurrentTotalCellOuts Gauge32
  atmVcCurrentClp0CellOuts Gauge32
  atmVcCurrentTaggedOuts Gauge32
  atmVcCurrentPCR Gauge32
  atmVcCurrentSCR Gauge32
  atmVcCurrentMCR Gauge32
  atmVcCurrentShaperTotalDiscards Gauge32
  atmVcCurrentShaperClp0Discards Gauge32
  atmVcCurrentShaperClp1Discards Gauge32

AtmVcPMCurrentEntry  
SEQUENCE    
  atmVcPMCurrentVpi Integer32
  atmVcPMCurrentVci Integer32
  atmVcPMCurrentDir Integer32
  atmVcPMCurrentTxClp01 Gauge32
  atmVcPMCurrentTxClp0 Gauge32
  atmVcPMCurrentRxClp01 Gauge32
  atmVcPMCurrentRxClp0 Gauge32
  atmVcPMCurrentErroredCells Gauge32
  atmVcPMCurrentLostCells Gauge32
  atmVcPMCurrentMisinsertedCells Gauge32
  atmVcPMCurrentECB Gauge32
  atmVcPMCurrentSECB Gauge32
  atmVcPMCurrentES Gauge32
  atmVcPMCurrentSES Gauge32
  atmVcPMCurrentUAS Gauge32
  atmVcPMCurrentIntervalQuality INTEGER
  atmVcPMCurrentLastDayQuality INTEGER

AtmVcIntervalEntry  
SEQUENCE    
  atmVcIntervalVpi Integer32
  atmVcIntervalVci Integer32
  atmVcIntervalNumber Integer32
  atmVcIntervalRxCellsClp01 Gauge32
  atmVcIntervalRxCellsClp0 Gauge32
  atmVcIntervalGcra0Violations Gauge32
  atmVcIntervalGcra1Violations Gauge32
  atmVcIntervalRxAIS Gauge32
  atmVcIntervalTxAIS Gauge32
  atmVcIntervalRxRDI Gauge32
  atmVcIntervalTxRDI Gauge32
  atmVcIntervalContinuityLoss Gauge32
  atmVcIntervalUAS Gauge32
  atmVcIntervalSES Gauge32
  atmVcIntervalCDC Gauge32
  atmVcIntervalTotalDiscards Gauge32
  atmVcIntervalClp0Discards Gauge32
  atmVcIntervalTotalCellOuts Gauge32
  atmVcIntervalClp0CellOuts Gauge32
  atmVcIntervalTaggedOuts Gauge32
  atmVcIntervalPCR Gauge32
  atmVcIntervalSCR Gauge32
  atmVcIntervalMCR Gauge32
  atmVcIntervalShaperTotalDiscards Gauge32
  atmVcIntervalShaperClp0Discards Gauge32
  atmVcIntervalShaperClp1Discards Gauge32

AtmVcPMIntervalEntry  
SEQUENCE    
  atmVcPMIntervalVpi Integer32
  atmVcPMIntervalVci Integer32
  atmVcPMIntervalDir INTEGER
  atmVcPMIntervalNumber Integer32
  atmVcPMIntervalTxClp01 Gauge32
  atmVcPMIntervalTxClp0 Gauge32
  atmVcPMIntervalRxClp01 Gauge32
  atmVcPMIntervalRxClp0 Gauge32
  atmVcPMIntervalErroredCells Gauge32
  atmVcPMIntervalLostCells Gauge32
  atmVcPMIntervalMisinsertedCells Gauge32
  atmVcPMIntervalECB Gauge32
  atmVcPMIntervalSECB Gauge32
  atmVcPMIntervalES Gauge32
  atmVcPMIntervalSES Gauge32
  atmVcPMIntervalUAS Gauge32
  atmVcPMIntervalQuality INTEGER
  atmVcPMIntervalLastDayQuality INTEGER

AtmVcQoSEntry  
SEQUENCE    
  atmVcQoSPeriodRef INTEGER
  atmVcQoSElapsedTime Integer32
  atmVcQoSUAS Gauge32

AtmVcPMQoSEntry  
SEQUENCE    
  atmVcPMQoSDirection INTEGER
  atmVcPMQoSPeriodRef INTEGER
  atmVcPMQoSCLR Gauge32
  atmVcPMQoSCER Gauge32
  atmVcPMQoSCMR Gauge32

AtmVcShaperStatEntry  
SEQUENCE    
  atmVcShaperDiscarded Counter32
  atmVcShaperOccupation Integer32
  atmVcShaperMaxOccupation Integer32
  atmVcShaperLevel INTEGER
  atmVcShaperEpdDropped Counter32
  atmVcShaperTotalEpdDropped Counter32

AtmIntervalDateEntry  
SEQUENCE    
  atmIntervalDateInterval Integer32
  atmIntervalDateDate DisplayString
  atmIntervalDateTime DisplayString

AtmNteManagerEntry  
SEQUENCE    
  atmNteManagerIP IpAddress
  atmNteManagerPvc Integer32
  atmNteManagerIfIndex Integer32
  atmNteManagerVpi Integer32
  atmNteManagerVci Integer32
  atmNteManagerTrapMask Integer32
  atmNteManagerRowStatus RowStatus
  atmNteManagerNextHop IpAddress
  atmNteManagerVlanSupport INTEGER
  atmNteManagerVlanIdentifier Integer32
  atmNteManagerVlanFramePriority Integer32
  atmNteManagerAlarmTrapMask OCTET STRING
  atmNteManagerConfigPorts Integer32

AtmNteConfOamIfEntry  
SEQUENCE    
  atmNteConfOamIfAisRdi INTEGER

AtmNteHostIfEntry  
SEQUENCE    
  atmNteHostPvcIndex Integer32
  atmNteHostIP IpAddress
  atmNteHostMask IpAddress
  atmNteHostAtmIfIndex Integer32
  atmNteHostVpi Integer32
  atmNteHostVci Integer32
  atmNteHostRowStatus RowStatus
  atmNteHostRdnVpi Integer32
  atmNteHostRdnVci Integer32
  atmNteHostDefaultNextHop IpAddress
  atmNteHostVlanTagging INTEGER
  atmNteHostDefaultVlanID Integer32
  atmNteHostDefaultVlanPriority Integer32

AtmNteOamEntry  
SEQUENCE    
  atmNteOamMode INTEGER
  atmNteOamCellType INTEGER
  atmNteOamLevel INTEGER
  atmNteOamEnable INTEGER

AtmAlarmForwardingEntry  
SEQUENCE    
  atmAlarmForwardingFailPort Integer32
  atmAlarmForwardingToPort Integer32
  atmAlarmForwardingRowStatus RowStatus
  atmAlarmForwardingFailureLevel BITS
  atmAlarmForwardingRecoveryMode INTEGER
  atmAlarmForwardingRecoveryCommand INTEGER
  atmAlarmForwardingTimeFilterWindow Unsigned32

AtmVpCrossConnectExtenEntry  
SEQUENCE    
  atmVpCrossConnectName SnmpAdminString

AtmVcCrossConnectExtenEntry  
SEQUENCE    
  atmVcCrossConnectName SnmpAdminString

AtmTrafficDescrParamXEntry  
SEQUENCE    
  atmTrafficDescrParamMode INTEGER

AtmNteIdEntry  
SEQUENCE    
  atmNteIdIndex Integer32
  atmNteUnitId Integer32
  atmNteUnitVersion DisplayString
  atmNteCardType INTEGER
  atmNteCardStatus INTEGER
  atmNteCardCmd INTEGER
  atmNteProgCardType INTEGER

AtmSysIntervalEntry  
SEQUENCE    
  atmSysIntervalNumber Integer32
  atmSysIntervalCdc Gauge32

AtmLoopbackVpEntry  
SEQUENCE    
  atmLoopbackVpIfIndex Integer32
  atmLoopbackVpVpi Integer32
  atmLoopbackVpOperStatus INTEGER
  atmLoopbackVpCDV Integer32
  atmLoopbackVpAverageDelay Integer32
  atmLoopbackVpMaxDelay Integer32
  atmLoopbackVpMinDelay Integer32
  atmLoopbackVpErrSessions Integer32

AtmLoopbackVcEntry  
SEQUENCE    
  atmLoopbackVcIfIndex Integer32
  atmLoopbackVcVpi Integer32
  atmLoopbackVcVci Integer32
  atmLoopbackVcOperStatus INTEGER
  atmLoopbackVcCDV Integer32
  atmLoopbackVcAverageDelay Integer32
  atmLoopbackVcMaxDelay Integer32
  atmLoopbackVcMinDelay Integer32
  atmLoopbackVcErrSessions Integer32

AtmLoopbackVpIvlEntry  
SEQUENCE    
  atmLoopbackVpIvlIfIndex Integer32
  atmLoopbackVpIvlVpi Integer32
  atmLoopbackVpIvlIvl Integer32
  atmLoopbackVpIvlOperStatus INTEGER
  atmLoopbackVpIvlCDV Integer32
  atmLoopbackVpIvlAverageDelay Integer32
  atmLoopbackVpIvlMaxDelay Integer32
  atmLoopbackVpIvlMinDelay Integer32
  atmLoopbackVpIvlErrSessions Integer32

AtmLoopbackVcIvlEntry  
SEQUENCE    
  atmLoopbackVcIvlIfIndex Integer32
  atmLoopbackVcIvlVpi Integer32
  atmLoopbackVcIvlVci Integer32
  atmLoopbackVcIvlIvl Integer32
  atmLoopbackVcIvlOperStatus INTEGER
  atmLoopbackVcIvlCDV Integer32
  atmLoopbackVcIvlAverageDelay Integer32
  atmLoopbackVcIvlMaxDelay Integer32
  atmLoopbackVcIvlMinDelay Integer32
  atmLoopbackVcIvlErrSessions Integer32

AtmVpPmEntry  
SEQUENCE    
  atmVpPmIfIndex Integer32
  atmVpPmVpi Integer32
  atmVpPmAdminStatus INTEGER
  atmVpPmDirection INTEGER
  atmVpPmBlockSize Integer32
  atmVpPmRowStatus RowStatus
  atmVpPmSink INTEGER
  atmVpPmSource INTEGER

AtmVcPmEntry  
SEQUENCE    
  atmVcPmIfIndex Integer32
  atmVcPmVpi Integer32
  atmVcPmVci Integer32
  atmVcPmAdminStatus INTEGER
  atmVcPmDirection INTEGER
  atmVcPmBlockSize Integer32
  atmVcPmRowStatus RowStatus
  atmVcPmSink INTEGER
  atmVcPmSource INTEGER

AtmNteMdlConfigEntry  
SEQUENCE    
  atmNteMdlSlotIndex Integer32
  atmNteMdlPrtCpuSharing INTEGER
  atmNteMdlInputPriorityMechanism INTEGER

AtmGenSysSelfTestEntry  
SEQUENCE    
  atmGenSysSelfTestIndex Integer32
  atmGenSysSelfTestResult DisplayString
  atmGenSysSelfTestModule DisplayString

AtmGenSysLogEntry  
SEQUENCE    
  atmGenSysLogIndex Integer32
  atmGenSysLogMessage DisplayString

AtmGenSysCxRefEntry  
SEQUENCE    
  atmGenSysCxRefIndex Integer32
  atmGenSysCxRefCounter Gauge32

Ip2IfEntry  
SEQUENCE    
  ip2IfChannelIndex Integer32
  ip2IfRowStatus RowStatus
  ip2IfOperStatus INTEGER
  ip2IfAdminStatus INTEGER
  ip2IfDestAddr IpAddress
  ip2IfNextHop IpAddress
  ip2IfDestPort Integer32
  ip2IfMacAddr MacAddress
  ip2IfJitterBuffer Integer32
  ip2IfTos Integer32
  ip2IfTDMBytesInFrame Integer32
  ip2IfVlanSupport INTEGER
  ip2IfVlanIdentifier Integer32
  ip2IfVlanFramePriority Integer32
  ip2IfExitPort INTEGER
  ip2IfVoiceOos OCTET STRING
  ip2IfDataOos OCTET STRING
  ip2IfBundleUsage Integer32
  ip2IfOAM OCTET STRING
  ip2IfTDMoIpMode INTEGER
  ip2IfTimeElapsed Integer32
  ip2IfValidIntervals Integer32
  ip2IfFarEndType INTEGER
  ip2IfRdnState INTEGER
  ip2IfSourceAddr IpAddress
  ip2IfBandWidth Integer32
  ip2IfMeasuredSilence Integer32
  ip2IfPayloadType INTEGER
  ip2IfProtocolVersion INTEGER
  ip2IfTdmBackUpNextHop IpAddress
  ip2IfOosTxEnable INTEGER
  ip2IfConnCheckPktFrequency Integer32
  ip2IfConnPktTimeOutCycles Integer32
  ip2IfMfRelay INTEGER
  ip2IfTxGain Integer32
  ip2IfSuperTandem INTEGER
  ip2IfSrcPort Integer32
  ip2IfModemCalls INTEGER
  ip2IfMinPulseWidth Integer32
  ip2IfMinPowerLevel Integer32
  ip2IfEchoCanceler INTEGER
  ip2IfCodingLaw INTEGER
  ip2IfCustomToneDetect INTEGER
  ip2IfCallerIdDelay Integer32
  ip2IfConnectivityMode INTEGER
  ip2IfClockSourceEnable INTEGER
  ip2IfNetworkType INTEGER
  ip2IfMplsRxLabelEnable INTEGER
  ip2IfMplsRxLabel Integer32
  ip2IfMplsTxLabelEnable INTEGER
  ip2IfMplsTxLabel Integer32
  ip2IfMplsTxExpBits Integer32
  ip2IfMfcSpoofing INTEGER
  ip2IfToneAckInterval Integer32
  ip2IfNextHopType INTEGER
  ip2IfNoiseLevelForVAD INTEGER
  ip2IfClockPreferences INTEGER
  ip2IfConnectionMode INTEGER
  ip2IfRingBack INTEGER
  ip2IfReversePolarity INTEGER
  ip2IfPulseMeter INTEGER
  ip2IfPulseMeterFreq INTEGER
  ip2IfPulseMeterPeriod Integer32
  ip2IfOnHookDetect INTEGER
  ip2IfComfortNoiseGen INTEGER
  ip2IfExitChannel Integer32
  ip2IfMaxVBDModemCalls Integer32
  ip2IfMaxRelayModemCalls Integer32
  ip2IfCustomToneFrequency INTEGER
  ip2IfVadMethod INTEGER
  ip2IfRxGain Integer32
  ip2IfCallerIDType INTEGER
  ip2IfPeerAddrType INTEGER
  ip2IfVbdRate INTEGER
  ip2IfDtmfDetection INTEGER
  ip2IfNlpCutoffLevel Unsigned32
  ip2IfDtdErlRatioCutoffQ3 Unsigned32
  ip2IfCASRedundancy INTEGER
  ip2IfBundleSensitivity INTEGER
  ip2IfOAMBundleIdent INTEGER
  ip2IfMaxTxQueue Unsigned32
  ip2IfMaxGprsTxQueue Unsigned32
  ip2IfV23HD INTEGER
  ip2IfModemProtocolMode OCTET STRING
  ip2IfCdisCngDetectionTime Unsigned32
  ip2IfSuperTandemBitMask OCTET STRING
  ip2IfVbdSwitchbackTime Unsigned32
  ip2IfCallerIdTxGain Integer32
  ip2IfCallerIdRxGain Integer32
  ip2IfUdpMuxMethod INTEGER
  ip2IfCallerIdDetection INTEGER
  ip2IfWap INTEGER

Ip2IfStatEntry  
SEQUENCE    
  ip2IfStatChIndex Integer32
  ip2IfStatSeqErrors Integer32
  ip2IfStatBufUnderflows Integer32
  ip2IfStatBufOverflows Integer32
  ip2IfStatTxOnTimeInterval Counter32
  ip2IfStatTxOnMaxSize Counter32
  ip2IfStatRxSignaling Counter32
  ip2IfStatRxVoice Counter32
  ip2IfStatRxHdlc Counter32
  ip2IfStatTxSignaling Counter32
  ip2IfStatTxVoice Counter32
  ip2IfStatTxHdlc Counter32
  ip2IfStatRdnFlip Counter32
  ip2IfFarEndTdmStatus Integer32
  ip2IfStatPsnTxFrames Counter32
  ip2IfStatPsnRxFrames Counter32
  ip2IfStatMinJittBufLevel Unsigned32
  ip2IfStatMaxJittBufLevel Unsigned32
  ip2IfStatRecommendedJittBufSize Unsigned32
  ip2IfStatPsnSeqErrors Counter32
  ip2IfStatPsnReorderFrames Counter32
  ip2IfStatMinRoundTripDelay Unsigned32
  ip2IfStatMaxRoundTripDelay Unsigned32
  ip2IfStatAvrRoundTripDelay Unsigned32
  ip2IfStatFrameTrackDupDrop Counter32
  ip2IfStatFrameTrackMissing Counter32
  ip2IfStatFrameTrackLongSerMiss Integer32
  ip2IfStatTxMeasuredSilence Integer32
  ip2IfStatRxMeasuredSilence Integer32
  ip2IfStatHdlcCrcErr Counter32
  ip2IfStatHdlcAlignErr Counter32
  ip2IfStatHdlcOversize Counter32
  ip2IfStatHdlcUndersize Counter32
  ip2IfStatHdlcAbort Counter32
  ip2IfStatRxCorrectFrames Counter32
  ip2IfStatHdlcErroredFrames Counter32

Ip2IfPortEntry  
SEQUENCE    
  ip2IfPortIndex Integer32
  ip2IfPortUsage Integer32
  ip2IfPortMask INTEGER
  ip2IfPortTotalThroughput Integer32

Ip2IfCurrentStatEntry  
SEQUENCE    
  ip2IfCurrentStatSeqErrors Counter32
  ip2IfCurrentStatBufUnderflows Counter32
  ip2IfCurrentStatBufOverflows Counter32
  ip2IfCurrentStatMaxDelayVar Integer32
  ip2IfCurrentStatMinJittBufLevel Unsigned32
  ip2IfCurrentStatMaxJittBufLevel Unsigned32
  ip2IfCurrentStatTxErrFrameSec Counter32

Ip2IfIntervalStatEntry  
SEQUENCE    
  ip2IfIntervalStatIndex Integer32
  ip2IfIntervalStatSeqErrors Counter32
  ip2IfIntervalStatBufUnderflows Counter32
  ip2IfIntervalStatBufOverflows Counter32
  ip2IfIntervalStatMaxDelayVar Integer32
  ip2IfIntervalStatMinJittBufLevel Unsigned32
  ip2IfIntervalStatMaxJittBufLevel Unsigned32
  ip2IfIntervalStatTxErrFrameSec Counter32

PrtBdbandIndEntry  
SEQUENCE    
  prtBdbandCnfgIdx Integer32
  prtBdbandIdx Integer32
  prtBdbandIndSig INTEGER
  prtBdbandIndEvent INTEGER
  prtBdbandIndSigEnable INTEGER
  prtBdbandRowStatus RowStatus

PrtPhyConfigEntry  
SEQUENCE    
  prtPhyTimeElapsed Integer32
  prtPhyValidIntervals Integer32

PrtPhyCurrentEntry  
SEQUENCE    
  prtPhyCurrentLOS Gauge32
  prtPhyCurrentLSV Gauge32
  prtPhyCurrentUAS Gauge32
  prtPhyCurrentSES Gauge32
  prtPhyCurrentES Gauge32
  prtPhyCurrentStatus OCTET STRING
  prtPhyCurrentLOF Gauge32

PrtPhyIntervalEntry  
SEQUENCE    
  prtPhyIntervalNumber Integer32
  prtPhyIntervalLOS Gauge32
  prtPhyIntervalLSV Gauge32
  prtPhyIntervalUAS Gauge32
  prtPhyIntervalSES Gauge32
  prtPhyIntervalES Gauge32
  prtPhyIntervalStatus OCTET STRING
  prtPhyIntervalLOF Gauge32

WrDhcpEntry  
SEQUENCE    
  wrDhcpLowIpAddress IpAddress
  wrDhcpHighIpAddress IpAddress
  wrDhcpIpMaskAddress IpAddress
  wrDhcpDefaultGateway IpAddress
  wrDhcpPrimaryDNS IpAddress
  wrDhcpSecondaryDNS IpAddress
  wrDhcpInterface INTEGER
  wrDhcpRowStatus RowStatus
  wrDhcpIpAddressLeaseTime Integer32
  wrDhcpPoolName SnmpAdminString
  wrDhcpTftpServerIp IpAddress
  wrDhcpConfigFileName SnmpAdminString

DhcpPoolAllocEntry  
SEQUENCE    
  dhcpPoolAllocLowIpAddress IpAddress
  dhcpPoolAllocLeasingIpAddress IpAddress
  dhcpPoolAllocMacAddress MacAddress
  dhcpPoolAllocTimeLeft Integer32
  dhcpPoolAllocFlags INTEGER
  dhcpPoolAllocFreeCmd INTEGER

DhcpRelayEntry  
SEQUENCE    
  dhcpRelayAction INTEGER
  dhcpRelayServerIpAddress IpAddress
  dhcpRelayMaxHop Integer32

DhcpClientEntry  
SEQUENCE    
  dhcpClientAction INTEGER
  dhcpClientServerIpAddress IpAddress
  dhcpClientLeaseExpirationTime Integer32
  dhcpClientStatus DisplayString

DhcpIfClientEntry  
SEQUENCE    
  dhcpIfClientIpAddress IpAddress
  dhcpIfClientRowStatus RowStatus

WrLanIpxNetEntry  
SEQUENCE    
  wrLanifIndex Integer32
  wrLanIpxFrameType INTEGER
  wrIpxNetAddress IpAddress

RipSapIfConfEntry  
SEQUENCE    
  ripSapIfConfIfIndex Integer32
  ripSapIfConfMode INTEGER
  ripSapIfConfStatus RowStatus

WrIpAddressEntry  
SEQUENCE    
  wrIpIfIndex Integer32
  wrIpAddress IpAddress
  wrIpMask IpAddress
  wrIpRowStatus RowStatus

WrSpoofingEntry  
SEQUENCE    
  wrSpoofingIfIndex Integer32
  wrSpoofingAction Integer32
  wrSpoofingAgingStation Integer32
  wrSpoofingRowStatus RowStatus

WrLanIfEntry  
SEQUENCE    
  wrLanIfIndex Integer32
  wrLanBridgeRouterMode INTEGER
  wrLanIfState INTEGER
  wrLanIfRdnTimeout Integer32

WrSyncCnfgEntry  
SEQUENCE    
  wrSyncIfIndex Integer32
  wrSyncClkMode INTEGER
  wrSyncClkRate INTEGER

WrFrCnfgEntry  
SEQUENCE    
  wrFrDlciLearningMode INTEGER
  wrFrCllmMessages INTEGER

SysDclEntry  
SEQUENCE    
  sysDclCnfgIdx Integer32
  sysDclRedundancy INTEGER
  sysDclActiveCl INTEGER
  sysDclFlipDelay Integer32
  sysDclFlipUponStnClk INTEGER
  sysDclChFailThreshold Integer32
  sysDclChPriority OCTET STRING
  sysDclConfigDownloadSrc INTEGER
  sysDclSwDownloadSrc INTEGER
  sysDclRedundancyStatus BITS

SysDclCopyDbEntry  
SEQUENCE    
  sysDclCopyDbIdx Integer32
  sysDclCopyDbCmd INTEGER

SysSErrListEntry  
SEQUENCE    
  sysSErrType INTEGER
  sysSErrIdx Integer32
  sysSErrDescription DisplayString

SysSRdnFlipEntry  
SEQUENCE    
  sysSRdnFlipIdx Integer32
  sysSRdnFlipSlot INTEGER
  sysSRdnFlipPort Integer32
  sysSRdnFlipCause DisplayString
  sysSRdnFlipDate DisplayString
  sysSRdnFlipTime DisplayString

SysSBusEntry  
SEQUENCE    
  sysSBusPortIdx Integer32
  sysSBusStatus INTEGER
  sysSBusCapturePort Integer32
  sysSBusUtilization Integer32

SysSAlrEntry  
SEQUENCE    
  sysSAlrIdx Integer32
  sysSAlrCode Integer32
  sysSAlrState INTEGER
  sysSAlarmMask INTEGER
  sysSAlarmInvert INTEGER
  sysSAlarmOnOff INTEGER
  sysSAlarmCounter Integer32

SysBufferAlrEntry  
SEQUENCE    
  sysBufferAlrIdx Integer32
  sysBufferAlrCode Integer32
  sysBufferAlrState INTEGER
  sysBufferAlrSlot INTEGER
  sysBufferAlrPort Integer32
  sysBufferAlrDate DisplayString
  sysBufferAlrTime DisplayString
  sysBufferAlrUpTime TimeTicks
  sysBufferAlrInfo SnmpAdminString

SysCClkSrcEntry  
SEQUENCE    
  sysCClkCnfgIdx Integer32
  sysCClkSrcIdx INTEGER
  sysCClkSrcMode INTEGER
  sysCClkSrcPrt Integer32
  sysCClkStationFreq INTEGER
  sysCClkRevertiveTimeout Integer32
  sysCClkStationIf INTEGER
  sysCClkStationCableMode INTEGER
  sysCClkStationOutState INTEGER
  sysCClkSsmBased INTEGER
  sysCClkSSubsystemSlot INTEGER
  sysCClkRecoveredID Unsigned32

SysCnfgEntry  
SEQUENCE    
  sysCnfgIdx Integer32
  sysCMatrixMode INTEGER
  sysCIsdnFormat INTEGER
  sysCRoutingOnEth INTEGER
  sysCAutoConfigEnable INTEGER
  sysCIntTsAllocMode INTEGER
  sysCBuPrimaryPort INTEGER
  sysCEnableLanOverTdm INTEGER
  sysCSs7FisuSuppression Integer32
  sysCBuRecMode INTEGER

SysCRdnEntry  
SEQUENCE    
  sysCRdnCnfgIdx Integer32
  sysCRdnPrimeSlot INTEGER
  sysCRdnPrimePort Integer32
  sysCRdnSecSlot INTEGER
  sysCRdnSecPort Integer32
  sysCRdnMode INTEGER
  sysCRdnRecMode INTEGER
  sysCRdnRecTime Integer32
  sysCRdnHwSwFlip INTEGER
  sysCRdnRowStatus RowStatus
  sysCRdnOnline INTEGER
  sysCRdnSwitchingMode INTEGER
  sysCRdnFlipUponEvent Integer32
  sysCRdnLosOrLofTime Integer32
  sysCRdnEventsTimeWindow Integer32
  sysCRdnSequenceNumberThreshold Integer32
  sysCRdnBufferErrorsThreshold Integer32
  sysCRdnBuffUnderrunTime Integer32
  sysCRdnPrimePriority INTEGER
  sysCRdnSecPriority INTEGER
  sysCRdnWTR Unsigned32
  sysCRdnName SnmpAdminString
  sysCRdnTxDownDurationUponFlip Unsigned32

SysSRdnCmdEntry  
SEQUENCE    
  sysSRdnEnforcedChannel INTEGER
  sysSRdnLockFlip INTEGER
  sysSRdnManualFlip INTEGER

SysDbaseFlipEntry  
SEQUENCE    
  sysDbaseFlipIdx Integer32
  sysDbaseFlipTime DisplayString
  sysDbaseFlipActivation INTEGER

MdlSEntry  
SEQUENCE    
  mdlSSltIdx INTEGER
  mdlSCardType INTEGER
  mdlSHwVer DisplayString
  mdlSSwVer DisplayString
  mdlSAlarmStatus INTEGER
  mdlSAlarmStatusAll INTEGER
  mdlSTestStatus INTEGER
  mdlSHwStatus INTEGER
  mdlSActivity INTEGER
  mdlSAlrClearCmd INTEGER
  mdlSAlrClearAllCmd INTEGER
  mdlSAlrMaskAll INTEGER
  mdlSCmd Integer32
  mdlSReset INTEGER
  mdlSRebuildFrame INTEGER
  mdlSBackupSwVer DisplayString
  mdlSSecondaryBackupSwVer DisplayString
  mdlSPiggybackVer SnmpAdminString

MdlCEntry  
SEQUENCE    
  mdlCConfigIdx Integer32
  mdlCSlotIdx INTEGER
  mdlCProgCardType INTEGER
  mdlCNoOfExtPrt Integer32
  mdlCNoOfIntPrt Integer32
  mdlCParam Integer32

MdlAlrEntry  
SEQUENCE    
  mdlAlrSltIdx INTEGER
  mdlAlrIdx Integer32
  mdlAlrCode Integer32
  mdlAlrState INTEGER
  mdlAlarmMask INTEGER
  mdlAlarmInvert INTEGER
  mdlAlarmOnOff INTEGER
  mdlAlarmCounter Integer32

MdlAlrMaskEntry  
SEQUENCE    
  mdlAlrMaskSltIdx INTEGER
  mdlAlrMask OCTET STRING

MdlClEntry  
SEQUENCE    
  mdlClIdx INTEGER
  mdlClSwchStatus Integer32
  mdlClLastFlipDate DisplayString
  mdlClLastFlipTime DisplayString
  mdlClLastFlipCause DisplayString

MdlPsEntry  
SEQUENCE    
  mdlPsIdx INTEGER
  mdlPsStatus INTEGER
  mdlPsTestResult INTEGER

PrtGenEntry  
SEQUENCE    
  prtGenPrtIdx Integer32
  prtGenSlt INTEGER
  prtGenExtInt INTEGER
  prtGenIfIndex Integer32
  prtGenActiveStatus INTEGER
  prtGenAlrStatus INTEGER
  prtGenTestStatus INTEGER
  prtGenTestMask Integer32
  prtGenTestCmd Integer32
  prtGenTestRunning Integer32
  prtGenType INTEGER
  prtGenInterfaceType DisplayString
  prtGenAlrClearCmd INTEGER
  prtGenAlrMaskAll INTEGER
  prtGenParamStatus OCTET STRING
  prtGenRdnStatus INTEGER
  prtGenTestMaskXP OCTET STRING
  prtGenTestCmdXP OCTET STRING
  prtGenTestRunningXP OCTET STRING

PrtGenTestDurationEntry  
SEQUENCE    
  prtGenTestPrtIdx Integer32
  prtGenTestIdx INTEGER
  prtGenTestDuration Integer32

PrtGenTsEntry  
SEQUENCE    
  prtGenTsCnfgIdx Integer32
  prtGenTsPrtIdx Integer32
  prtGenTsIdx Integer32
  prtGenTsType INTEGER
  prtGenTsIConPrt Integer32
  prtGenTsIConTs Integer32

PrtSAlarmEntry  
SEQUENCE    
  prtSAlarmPrtIdx Integer32
  prtSAlarmIdx Integer32
  prtSAlarmCode Integer32
  prtSAlarmState INTEGER
  prtSAlarmMask INTEGER
  prtSAlarmInvert INTEGER
  prtSAlarmOnOff INTEGER
  prtSAlarmCounter Integer32

PrtAlrMaskEntry  
SEQUENCE    
  prtAlrMaskPrtIdx Integer32
  prtAlrMask OCTET STRING

PrtBertEntry  
SEQUENCE    
  prtBertPrtIdx Integer32
  prtBertPattern INTEGER
  prtBertInjectRate INTEGER
  prtBertInjectErrRateCmd INTEGER
  prtBertInjectSingleErrCmd INTEGER
  prtBertRunTime Integer32
  prtBertESs Integer32
  prtBertSyncLoss Integer32
  prtBertErrorBits Integer32
  prtBertClearCounters INTEGER
  prtBertSyncStatus INTEGER
  prtBertTs OCTET STRING
  prtBertResult DisplayString
  prtBertTxBits Integer32
  prtBertRxBits Integer32
  prtBertTxErrorBits Integer32

PrtMonEntry  
SEQUENCE    
  prtMonCnfgIdx Integer32
  prtMonitoringIdx Integer32
  prtMonitoringEnable INTEGER
  prtMonitoringTSs OCTET STRING
  prtMonitoredPort Integer32
  prtMonitoredTSs OCTET STRING

PrtCfgParamEntry  
SEQUENCE    
  prtCfgParamCnfgIdx Integer32
  prtCfgParamIdx Integer32
  prtCfgParamSlt INTEGER
  prtCfgParamOperatedMl INTEGER
  prtCfgParamMlAtoMlBPrio INTEGER
  prtCfgParamMlBtoMlAPrio INTEGER
  prtCfgParamInbandLoopDetection INTEGER
  prtCfgParamInbandLoopPatternCfg INTEGER
  prtCfgParamInbandLoopActPattern DisplayString
  prtCfgParamInbandLoopDeactPattern DisplayString

PrtT1E1StatEntry  
SEQUENCE    
  prtT1E1SPrtIdx Integer32
  prtT1E1SSlt INTEGER
  prtT1E1OosCount Gauge32
  prtT1E1BpvLastMin Gauge32
  prtT1E1BpvMax Gauge32

PrtT1E1CnfgEntry  
SEQUENCE    
  prtT1E1CnfgIdx Integer32
  prtT1E1PrtIdx Integer32
  prtT1E1Slt INTEGER
  prtT1E1LineType INTEGER
  prtT1E1LineCode INTEGER
  prtT1E1SignalMode INTEGER
  prtT1E1Fdl INTEGER
  prtT1E1FdlMode INTEGER
  prtT1E1Sync INTEGER
  prtT1E1CGA INTEGER
  prtT1E1IdleCode OCTET STRING
  prtT1E1OosSignal INTEGER
  prtT1E1VoiceOos OCTET STRING
  prtT1E1DataOos OCTET STRING
  prtT1E1LineLengthMask INTEGER
  prtT1E1TxGainMask INTEGER
  prtT1E1InbandMng INTEGER
  prtT1E1InbandMngRate INTEGER
  prtT1E1DedicatedTs Integer32
  prtT1E1InbandMngRoutProt INTEGER
  prtT1E1LinkMode INTEGER
  prtT1E1Multiplier INTEGER
  prtT1E1RxGain INTEGER
  prtT1E1RAI INTEGER
  prtT1E1LineMode INTEGER
  prtT1E1TS0SaBits OCTET STRING
  prtT1E1ConnectedTS INTEGER
  prtT1E1Ts0SaBit INTEGER
  prtT1E1SameFeCnfg INTEGER
  prtT1E1RemCrc4 INTEGER
  prtT1E1MaxTSs Integer32
  prtT1E1EocTsConfig INTEGER
  prtT1E1Role INTEGER
  prtT1E1PppEchoFailDetection INTEGER

PrtT1E1FdlMsgEntry  
SEQUENCE    
  prtT1E1FdlMsgPrtIdx Integer32
  prtT1E1FdlMsgFdlType INTEGER
  prtT1E1FdlMsgSlt INTEGER
  prtT1E1FdlMsg OCTET STRING

PrtHSParamEntry  
SEQUENCE    
  prtHSCnfgIdx Integer32
  prtHSPrtIdx Integer32
  prtHSSlt INTEGER
  prtHSRate INTEGER
  prtHSFifoSize INTEGER
  prtHSClkMode INTEGER
  prtHSCTS INTEGER
  prtHSRtsState INTEGER
  prtHSInbandLoopback INTEGER
  prtHSInbandLoopPatternCfg INTEGER
  prtHSInbandLoopActPattern DisplayString
  prtHSInbandLoopDeactPattern DisplayString
  prtHSDCD INTEGER
  prtHSClkPolarity INTEGER
  prtHSInterfaceType INTEGER
  prtHSUnframed INTEGER

PrtHSBertEntry  
SEQUENCE    
  prtHSBertPrtIdx Integer32
  prtHSBertSlt INTEGER
  prtHSBertCountClr INTEGER
  prtHSBertTestResult Integer32

PrtSpCnfgEntry  
SEQUENCE    
  prtSpCnfgIdx Integer32
  prtSpPrtIdx Integer32
  prtSpUsage INTEGER
  prtSpRate INTEGER
  prtSpDataBits INTEGER
  prtSpParity INTEGER
  prtSpCallOutMode INTEGER
  prtSpInterface INTEGER
  prtSpCTS INTEGER
  prtSpDcdDelay INTEGER
  prtSpDsr INTEGER
  prtSpNoOfRetries Integer32
  prtSpWaitForConnect INTEGER
  prtSpDialMode INTEGER
  prtSpAltNumMode INTEGER
  prtSpPrimaryNum DisplayString
  prtSpAltNum DisplayString
  prtSpRoutProtocol INTEGER
  prtSpCmd OCTET STRING
  prtSpActCallOut INTEGER
  prtSpAlrRelayMode INTEGER
  prtSpStopBits INTEGER

PrtDimCnfgEntry  
SEQUENCE    
  prtDimCnfgIdx Integer32
  prtDimIdx Integer32
  prtDimTxMode INTEGER
  prtDimPolarity INTEGER
  prtDimClkMode INTEGER
  prtDimMaxDelay INTEGER
  prtDimMng INTEGER
  prtDimMngRoutProt INTEGER

PrtDimDestEntry  
SEQUENCE    
  prtDestCnfgIdx Integer32
  prtDestDimIdx Integer32
  prtDestIdx Integer32
  prtDest Integer32
  prtDestConnect INTEGER

PrtICnfgEntry  
SEQUENCE    
  prtICnfgIdx Integer32
  prtIIdx Integer32
  prtIRate INTEGER
  prtIConnect INTEGER

PrtHdslEntry  
SEQUENCE    
  prtHdslIdx Integer32
  prtHdslMode INTEGER
  prtHdslRptrType INTEGER
  prtHdslMaxRate INTEGER
  prtHdslLinkType INTEGER
  prtHdslCompSwVer DisplayString
  prtHdslCompHwVer DisplayString

PrtT3E3CnfgEntry  
SEQUENCE    
  prtT3E3CnfgIdx Integer32
  prtT3E3PrtIdx Integer32
  prtT3E3Slt INTEGER
  prtT3E3LineLength INTEGER
  prtT3E3InbandMng INTEGER
  prtT3E3AisFrame INTEGER
  prtT3E3TxClockSource INTEGER
  prtT3E3RoutProt INTEGER
  prtT3E3AisTransmit INTEGER

CmprEntry  
SEQUENCE    
  cmprTypeIdx Integer32
  cmprCnfgIdx Integer32
  cmprVersion Integer32
  cmprSltIdx INTEGER
  cmprPrtIdx Integer32
  cmprObj OCTET STRING

MapLinkEntry  
SEQUENCE    
  mapLinkIdx Integer32
  mapLinkSlotIdx INTEGER
  mapLinkPortIdx Integer32
  mapLinkState INTEGER

AlrGenEntry  
SEQUENCE    
  alrGenCode Integer32
  alrGenDescription DisplayString
  alrGenLevel INTEGER
  alrGenSlotType INTEGER
  alrGenSeverity INTEGER
  alrGenDebounce Integer32
  alrGenDefSeverity INTEGER

WfqEntry  
SEQUENCE    
  wfqCnfgIdx Integer32
  wfqPrtIdx Integer32
  wfqTblIdx Integer32
  wfqQueueIdx Integer32
  wfqRowStatus RowStatus
  wfqWeightValue Integer32
  wfqSchedulingMode INTEGER
  wfqMinRateAbsolute Unsigned32
  wfqMaxPacketSize Unsigned32

Dscp  
A Differentiated Services Code-Point that may be used for marking a traffic stream.
TEXTUAL-CONVENTION    
  Integer32 0..63  

DscpMappingEntry  
SEQUENCE    
  dscpMappingCnfgIdx Integer32
  dscpMappingDscpIdx Dscp
  dscpMappingRegenPriority Integer32

IfTeQosEntry  
SEQUENCE    
  ifTeQosIdx1 Integer32
  ifTeQosIdx2 Integer32
  ifTeQosIdx3 Integer32
  ifTeQosParam OCTET STRING
  ifTeQosParam2 OCTET STRING
  ifTeQosStatus INTEGER

PrtPriorityEntry  
SEQUENCE    
  prtPriorityIdx1 Integer32
  prtPriorityPrtIdx Integer32
  prtPriorityIdx Integer32
  prtPriorityIngressRateLimit Integer32

PrtQosEntry  
SEQUENCE    
  prtQosIdx Unsigned32
  prtQosPrtIdx Unsigned32
  prtQosDirection INTEGER
  prtQosRateLimitPacketType INTEGER
  prtQosRateLimitCIR Unsigned32
  prtQosRateLimitCBS Unsigned32
  prtQosRateLimitEIR Unsigned32
  prtQosRateLimitEBS Unsigned32

PortTrafficClassEntry  
SEQUENCE    
  portTrafficClassIdx1 Integer32
  portTrafficClassPortIdx Integer32
  portTrafficClass Integer32

ServiceEntry  
SEQUENCE    
  flowIndex Unsigned32
  serviceIndex Unsigned32
  serviceRowStatus RowStatus
  serviceName SnmpAdminString
  serviceBwProfileId Unsigned32

EvcCosEntry  
SEQUENCE    
  evcCosCnfgIdx Unsigned32
  evcCosEvcIdx Unsigned32
  evcCosRowStatus RowStatus
  evcCosEvcName SnmpAdminString
  evcCosSpVlanId Unsigned32

ServiceStatEntry  
SEQUENCE    
  serviceStatDirection INTEGER
  srvForwardGreenPackets Gauge32
  srvForwardGreenPacktesOverflow Gauge32
  srvForwardYellowPackets Gauge32
  srvForwardYellowPacketsOverflow Gauge32
  srvDiscardGreenPacket Gauge32
  srvDiscardGreenPacketOverflow Gauge32
  srvDiscardYellowRedPackets Gauge32
  srvDiscardYellowRedPacketsOverflow Gauge32
  srvForwardGreenBytes Gauge32
  srvForwardGreenBytesOverflow Gauge32
  srvForwardYellowBytes Gauge32
  srvForwardYellowBytesOverflow Gauge32
  srvDiscardGreenBytes Gauge32
  srvDiscardGreenBytesOverflow Gauge32
  srvDiscardYellowRedBytes Gauge32
  srvDiscardYellowRedBytesOverflow Gauge32
  srvResetStatsCmd INTEGER
  srvDiscardYellowPackets Gauge32
  srvDiscardYellowPacketsOverflow Gauge32
  srvDiscardYellowBytes Gauge32
  srvDiscardYellowBytesOverflow Gauge32
  srvDiscardRedPackets Gauge32
  srvDiscardRedPacketsOverflow Gauge32
  srvDiscardRedBytes Gauge32
  srvDiscardRedBytesOverflow Gauge32

FlowMappingProfileEntry  
SEQUENCE    
  flowMappingProfileIndex Unsigned32
  flowMappingProfilePriority INTEGER
  flowMappingProfileRowStatus RowStatus
  flowMappingProfileNumOfMaps Unsigned32
  flowMappingProfileMapIndex Unsigned32
  flowMappingProfileName SnmpAdminString

QosFlowMappingEntry  
SEQUENCE    
  qosFlowMappingIdx1 Unsigned32
  qosFlowMappingIdx2 Unsigned32
  qosFlowMappingIdx3 Unsigned32
  qosFlowMappingRowStatus RowStatus
  qosFlowMappingCriteria BITS
  qosFlowMappingIeee802dot1p Unsigned32
  qosFlowMappingTos Unsigned32
  qosFlowMappingFromDscp Unsigned32
  qosFlowMappingToDscp Unsigned32
  qosFlowMappingFromVlanId Unsigned32
  qosFlowMappingToVlanId Unsigned32
  qosFlowMappingFromSrcMacAddr MacAddress
  qosFlowMappingToSrcMacAddr MacAddress
  qosFlowMappingFromDestMacAddr MacAddress
  qosFlowMappingToDestMacAddr MacAddress
  qosFlowMappingFromSrcIpAddr IpAddress
  qosFlowMappingToSrcIpAddr IpAddress
  qosFlowMappingFromDestIpAddr IpAddress
  qosFlowMappingToDestIpAddr IpAddress
  qosFlowMappingFromTcpSrcPort Unsigned32
  qosFlowMappingToTcpSrcPort Unsigned32
  qosFlowMappingFromTcpDestPort Unsigned32
  qosFlowMappingToTcpDestPort Unsigned32
  qosFlowMappingFromUdpSrcPort Unsigned32
  qosFlowMappingToUdpSrcPort Unsigned32
  qosFlowMappingFromUdpDestPort Unsigned32
  qosFlowMappingToUdpDestPort Unsigned32
  qosFlowMappingFromIpPrecedence Unsigned32
  qosFlowMappingToIpPrecedence Unsigned32
  qosFlowMappingInnerIeee802dot1p Unsigned32
  qosFlowMappingFromInnerVlanId Unsigned32
  qosFlowMappingToInnerVlanId Unsigned32

CosProfileEntry  
SEQUENCE    
  cosProfileIndex Unsigned32
  cosProfileRowStatus RowStatus
  cosProfileCosMethod INTEGER
  cosProfileName SnmpAdminString
  cosProfileCosMapping OCTET STRING

QProfileEntry  
SEQUENCE    
  qProfileIndex Unsigned32
  qProfileRowStatus RowStatus
  qProfileName SnmpAdminString
  qProfileNumberOfInternalQ Unsigned32
  qProfileInternalQProfile OCTET STRING

QInternalProfileEntry  
SEQUENCE    
  qInternalProfileIndex Unsigned32
  qInternalProfileRowStatus RowStatus
  qInternalProfileScheduling INTEGER
  qInternalProfileWFQWeight Unsigned32
  qInternalProfileQueueLength Unsigned32
  qInternalProfileWredStartDropThresh Unsigned32
  qInternalProfileWredDropAllThresh Unsigned32
  qInternalProfileWredDropProbability Unsigned32
  qInternalProfileRateLimit Unsigned32
  qInternalProfileShaperProfile Unsigned32

QueueGroupEntry  
SEQUENCE    
  queueGroupName SnmpAdminString
  queueGroupQBlockLevel Unsigned32
  queueGroupQBlockIdx Unsigned32
  queueGroupRowStatus RowStatus
  queueGroupQBlockProfile Unsigned32
  queueGroupQBlockShaperProfile Unsigned32
  queueGroupPointToQBlock SnmpAdminString
  queueGroupPointToInternalQueue Unsigned32
  queueGroupQBlockName SnmpAdminString

MarkingProfileEntry  
SEQUENCE    
  markingProfileIndex Unsigned32
  markingProfileRowStatus RowStatus
  markingProfileName SnmpAdminString
  markingSpVlanPBit OCTET STRING
  markingProfileMethod INTEGER

EthIfEntry  
SEQUENCE    
  ethIfIdx Integer32
  ethMode INTEGER
  ethBridgingMode INTEGER
  ethEncapsulationCRCMode INTEGER
  ethBackPressure INTEGER
  ethLimit4 INTEGER
  ethSkipInitReset INTEGER
  ethMulticastBlock INTEGER
  ethBroadcastBlock INTEGER
  ethSpeed INTEGER
  ethRip2 INTEGER
  ethPortPriority INTEGER
  ethPortMngEnable INTEGER
  ethFlowCtrlMacAddress MacAddress
  ethRateLimit Integer32
  ethJumboFrameEnable INTEGER
  ethAutoMdiXEnable INTEGER
  ethPortDataEnable INTEGER
  ethIfUse Integer32
  ethLineOam INTEGER
  ethRoutingProtocol INTEGER
  ethMdiXManualSwitch INTEGER
  ethDot1xEnable INTEGER
  ethPartnerRateMode INTEGER
  ethDot1xPortRole INTEGER

EthIfCurrentEntry  
SEQUENCE    
  ethIfCurrentIndex Integer32
  ethIfCurrentStatus OCTET STRING
  ethIfCurrentInFrames Gauge32
  ethIfCurrentInOctets Gauge32
  ethIfCurrentAlignmentErrors Gauge32
  ethIfCurrentFCSErrors Gauge32
  ethIfCurrentLengthError Gauge32
  ethIfCurrentOutFrames Gauge32
  ethIfCurrentOutOctets Gauge32
  ethIfCurrentSingleCollisionFrames Gauge32
  ethIfCurrentMultipleCollisionFrames Gauge32
  ethIfCurrentDeferredTransmissions Gauge32
  ethIfCurrentLateCollisions Gauge32
  ethIfCurrentCarrierSenseErrors Gauge32
  ethIfCurrentInputCongestionDropped Gauge32
  ethIfCurrentOutputCongestionDropped Gauge32
  ethIfCurrentOverflowInFrames Gauge32
  ethIfCurrentOverflowInOctets Gauge32
  ethIfCurrentOverflowFCSErrors Gauge32
  ethIfCurrentOverflowOutFrames Gauge32
  ethIfCurrentOverflowOutOctets Gauge32
  ethIfCurrentOverflowMultipleCollisionFrames Gauge32
  ethIfCurrentInUnicastFrames Gauge32
  ethIfCurrentOutUnicastFrames Gauge32
  ethIfCurrentInMulticastFrames Gauge32
  ethIfCurrentOutMulticastFrames Gauge32
  ethIfCurrentInBroadcastFrames Gauge32
  ethIfCurrentOutBroadcastFrames Gauge32
  ethIfCurrentInDiscardFrames Gauge32
  ethIfCurrentOutDiscardFrames Gauge32
  ethIfCurrentInPauseFrames Gauge32
  ethIfCurrentOutPauseFrames Gauge32
  ethIfCurrentOverflowInUnicastFrames Gauge32
  ethIfCurrentOverflowOutUnicastFrames Gauge32
  ethIfCurrentOverflowInMulticastFrames Gauge32
  ethIfCurrentOverflowOutMulticastFrames Gauge32
  ethIfCurrentOverflowInBroadcastFrames Gauge32
  ethIfCurrentOverflowOutBroadcastFrames Gauge32
  ethIfCurrentOverflowInDiscardFrames Gauge32
  ethIfCurrentOverflowOutDiscardFrames Gauge32
  ethIfCurrentOverflowInPauseFrames Gauge32
  ethIfCurrentOverflowOutPauseFrames Gauge32

EthIfIntervalEntry  
SEQUENCE    
  ethIfIntervalIndex Integer32
  ethIfIntervalNumber Integer32
  ethIfIntervalStatus OCTET STRING
  ethIfIntervalInFrames Gauge32
  ethIfIntervalInOctets Gauge32
  ethIfIntervalAlignmentErrors Gauge32
  ethIfIntervalFCSErrors Gauge32
  ethIfIntervalLengthError Gauge32
  ethIfIntervalOutFrames Gauge32
  ethIfIntervalOutOctets Gauge32
  ethIfIntervalSingleCollisionFrames Gauge32
  ethIfIntervalMultipleCollisionFrames Gauge32
  ethIfIntervalDeferredTransmissions Gauge32
  ethIfIntervalLateCollisions Gauge32
  ethIfIntervalCarrierSenseErrors Gauge32
  ethIfIntervalInputCongestionDropped Gauge32
  ethIfIntervalOutputCongestionDropped Gauge32
  ethIfIntervalOverflowInFrames Gauge32
  ethIfIntervalOverflowInOctets Gauge32
  ethIfIntervalOverflowFCSErrors Gauge32
  ethIfIntervalOverflowOutFrames Gauge32
  ethIfIntervalOverflowOutOctets Gauge32
  ethIfIntervalOverflowMultipleCollisionFrames Gauge32
  ethIfIntervalInUnicastFrames Gauge32
  ethIfIntervalOutUnicastFrames Gauge32
  ethIfIntervalInMulticastFrames Gauge32
  ethIfIntervalOutMulticastFrames Gauge32
  ethIfIntervalInBroadcastFrames Gauge32
  ethIfIntervalOutBroadcastFrames Gauge32
  ethIfIntervalInDiscardFrames Gauge32
  ethIfIntervalOutDiscardFrames Gauge32
  ethIfIntervalInPauseFrames Gauge32
  ethIfIntervalOutPauseFrames Gauge32
  ethIfIntervalOverflowInUnicastFrames Gauge32
  ethIfIntervalOverflowOutUnicastFrames Gauge32
  ethIfIntervalOverflowInMulticastFrames Gauge32
  ethIfIntervalOverflowOutMulticastFrames Gauge32
  ethIfIntervalOverflowInBroadcastFrames Gauge32
  ethIfIntervalOverflowOutBroadcastFrames Gauge32
  ethIfIntervalOverflowInDiscardFrames Gauge32
  ethIfIntervalOverflowOutDiscardFrames Gauge32
  ethIfIntervalOverflowInPauseFrames Gauge32
  ethIfIntervalOverflowOutPauseFrames Gauge32

EthIfPerfEntry  
SEQUENCE    
  ethIfPerfInOkFrames Gauge32
  ethIfPerfOutOkFrames Gauge32
  ethIfPerfTotalCollisions Gauge32
  ethIfPerfInOkOctets Gauge32

RadMepEntry  
SEQUENCE    
  radOamIdx1 Unsigned32
  radOamEvcIdx Unsigned32
  radMepIdx Unsigned32
  radMepRowStatus RowStatus
  radMepLocalMepId Unsigned32
  radMepRemoteMepId Unsigned32
  radMepOamMode INTEGER
  radMepContinuityVerMode INTEGER
  radMepMeLevel Unsigned32
  radMepOamDestAddrType INTEGER
  radMepOamDestMacAddr MacAddress
  radMepDefaultPriority Unsigned32
  radMepCcStatus INTEGER
  radMepOamProtocol INTEGER
  radMepMdId Unsigned32
  radMepMaFormat INTEGER
  radMepMaName OCTET STRING
  radMepSpVlanId Unsigned32
  radMepCcInterval INTEGER
  radMepTransmitLbmDestMacAddress MacAddress
  radMepTransmitLbmDestMepId Unsigned32
  radMepTransmitLbmDestIsMepId INTEGER
  radMepTransmitLbmMassages Integer32
  radMepTransmitLbmVlanPriority Unsigned32
  radMepTransmitLbmVlanDropEnable INTEGER
  radMepLbrIn Counter32
  radMepLbrInOutOfOrder Counter32
  radMepLbmOut Counter32
  radMepTransmitLtmTargetMacAddress MacAddress
  radMepTransmitLtmTargetMepId Unsigned32
  radMepTransmitLtmTargetIsMepId INTEGER
  radMepTransmitLtmTtl Unsigned32
  radMepTransmitLtmActivationCmd INTEGER

EthOamServiceEntry  
SEQUENCE    
  ethOamServiceIdx Unsigned32
  ethOamServiceRowStatus RowStatus
  ethOamServicePriority Unsigned32
  ethOamServicePmEnable INTEGER
  ethOamServiceFrameLossRatioThresh Integer32
  ethOamServiceDelayThresh Integer32
  ethOamServiceDelayVarThresh Integer32
  ethOamServiceUnavailRatioThresh Integer32
  ethOamServiceTxFrames Counter32
  ethOamServiceOverflowTxFrames Counter32
  ethOamServiceFrameLoss Counter32
  ethOamServiceOverflowFrameLoss Counter32
  ethOamServiceFrameLossRatio Unsigned32
  ethOamServiceElapsedTime Counter32
  ethOamServiceUnavailSec Counter32
  ethOamServiceUnavailRatio Unsigned32
  ethOamServiceFramesAboveDelay Counter32
  ethOamServiceOverflowFramesAboveDelay Counter32
  ethOamServiceFramesAboveDelayVar Counter32
  ethOamServiceOverflowFramesAboveDelayVar Counter32

EthOamSvcCurrentStatEntry  
SEQUENCE    
  ethOamSvcCurrFramesAboveDelayThresh PerfCurrentCount
  ethOamSvcCurrFramesBelowDelayThresh PerfCurrentCount
  ethOamSvcCurrFramesAboveDVarThresh PerfCurrentCount
  ethOamSvcCurrFramesBelowDVarThresh PerfCurrentCount
  ethOamSvcCurrFramesTxCounter PerfCurrentCount
  ethOamSvcCurrFramesLossCounter PerfCurrentCount
  ethOamSvcCurrMinRoundTripDelay Unsigned32
  ethOamSvcCurrMaxRoundTripDelay Unsigned32
  ethOamSvcCurrAvgRoundTripDelay Unsigned32
  ethOamSvcCurrMaxRoundTripDVar Unsigned32
  ethOamSvcCurrAvgRoundTripDVar Unsigned32
  ethOamSvcCurrElapsedTime Integer32
  ethOamSvcCurrUnavailSec PerfCurrentCount

EthOamSvcIntervalEntry  
SEQUENCE    
  ethOamSvcIntervalNum Integer32
  ethOamSvcIntervalFramesAboveDelayThresh PerfIntervalCount
  ethOamSvcIntervalFramesBelowDelayThresh PerfIntervalCount
  ethOamSvcIntervalFramesAboveDVarThresh PerfIntervalCount
  ethOamSvcIntervalFramesBelowDVarThresh PerfIntervalCount
  ethOamSvcIntervalFramesTxCounter PerfIntervalCount
  ethOamSvcIntervalFramesLossCounter PerfIntervalCount
  ethOamSvcIntervalMinRoundTripDelay Unsigned32
  ethOamSvcIntervalMaxRoundTripDelay Unsigned32
  ethOamSvcIntervalAvgRoundTripDelay Unsigned32
  ethOamSvcIntervalMaxRoundTripDVar Unsigned32
  ethOamSvcIntervalAvgRoundTripDVar Unsigned32
  ethOamSvcIntervalUnavailSec PerfIntervalCount

EthOamSvcTotalEntry  
SEQUENCE    
  ethOamSvcTotalFramesAboveDelayThresh PerfTotalCount
  ethOamSvcTotalFramesBelowDelayThresh PerfTotalCount
  ethOamSvcTotalFramesAboveDVarThresh PerfTotalCount
  ethOamSvcTotalFramesBelowDVarThresh PerfTotalCount
  ethOamSvcTotalFramesTxCounter PerfTotalCount
  ethOamSvcTotalFramesLossCounter PerfTotalCount
  ethOamSvcTotalMinRoundTripDelay Unsigned32
  ethOamSvcTotalMaxRoundTripDelay Unsigned32
  ethOamSvcTotalAvgRoundTripDelay Unsigned32
  ethOamSvcTotalMaxRoundTripDVar Unsigned32
  ethOamSvcTotalAvgRoundTripDVar Unsigned32
  ethOamSvcTotalUnavailSec PerfTotalCount

RadMdEntry  
SEQUENCE    
  radMdIndex Unsigned32
  radMdFormat INTEGER
  radMdName OCTET STRING
  radMdRowStatus RowStatus

RadMepLtrEntry  
SEQUENCE    
  radMepLtrReceiveOrder Unsigned32
  radMepLtrTtl Unsigned32
  radMepLtrMacAddr MacAddress
  radMepLtrRelay INTEGER
  radMepLtrIngress INTEGER
  radMepLtrIngressPortIdSubtype LldpPortIdSubtype
  radMepLtrIngressPortId OCTET STRING
  radMepLtrEgress INTEGER
  radMepLtrEgressPortIdSubtype LldpPortIdSubtype
  radMepLtrEgressPortId OCTET STRING

RadMepCcStatusEntry  
SEQUENCE    
  radMepRemoteMepIdx Unsigned32
  radMepCcStatusRemMepId Unsigned32
  radMepCcStat INTEGER
  radMepCcStatusMacAddr MacAddress

Dot1agXCfmMdEntry  
SEQUENCE    
  dot1agXCfmMdProtocol INTEGER

Dot1agXCfmMepEntry  
SEQUENCE    
  dot1agXCfmMepContinuityVerMode INTEGER
  dot1agXCfmMepDestAddrType INTEGER
  dot1agXCfmMepDestMacAddr MacAddress

Dot1agXCfmMepDbEntry  
SEQUENCE    
  dot1agXCfmMepCcStat INTEGER

EthIfRingEntry  
SEQUENCE    
  ethIfRingIdx Unsigned32
  ethIfRingAdminStatus INTEGER
  ethIfRingPorts PortList
  ethIfRingOperStatus INTEGER
  ethIfRingKeepAliveInterval Unsigned32
  ethIfRingKeepAliveThresh Unsigned32
  ethIfRingKeepAliveVlanId Unsigned32
  ethIfRingMultiCastVlanId Unsigned32
  ethIfRingRowStatus INTEGER

EthIfStormEntry  
SEQUENCE    
  ethIfStormCnfgIdx Unsigned32
  ethIfStormIfIdx Unsigned32
  ethIfStormDirection INTEGER
  ethIfStormPacketType BITS
  ethIfStormCtrlEnable INTEGER
  ethIfStormMaxRate Unsigned32

Dot3OamDescrEntry  
SEQUENCE    
  dot3OamDescrId Unsigned32
  dot3OamDescrRowStatus RowStatus
  dot3OamDescrMode INTEGER
  dot3OamDescrLbRxOperation INTEGER
  dot3OamDescrRateLimit Unsigned32

Dot3OamXEntry  
SEQUENCE    
  dot3OamXDescrId Unsigned32
  dot3OamXPeerState INTEGER

EthIfSrcMacCtrlEntry  
SEQUENCE    
  ethIfSrcMacCtrlIndex Unsigned32
  ethIfSrcMacCtrlIdx2 Unsigned32
  ethIfSrcMacCtrl INTEGER
  ethIfSrcMacCtrlMaxPermitAddr Unsigned32
  ethIfSrcMacCtrlCurNumPermitAddr Unsigned32
  ethIfSrcMacCtrlFlushAddrCmd INTEGER
  ethIfSrcMacCtrlAging Unsigned32
  ethIfSrcMacCtrlLocking INTEGER
  ethIfSrcMacCtrlViolationAction INTEGER
  ethIfSrcMacCtrlLastViolatingAddr MacAddress
  ethIfSrcMacCtrlPortStatus INTEGER

EthIfSrcMacCtrlAddrEntry  
SEQUENCE    
  ethIfSrcMacCtrlAddrIndex Unsigned32
  ethIfSrcMacCtrlAddr MacAddress
  ethIfSrcMacCtrlAddrIdx3 Unsigned32
  ethIfSrcMacCtrlAddrRowStatus INTEGER
  ethIfSrcMacCtrlAddrStatus INTEGER

Defined Values

rad 1.3.6.1.4.1.164
OBJECT IDENTIFIER    

radTokenRing 1.3.6.1.4.1.164.1
OBJECT IDENTIFIER    

radFddi 1.3.6.1.4.1.164.2
OBJECT IDENTIFIER    

radWan 1.3.6.1.4.1.164.3
OBJECT IDENTIFIER    

radBridges 1.3.6.1.4.1.164.4
OBJECT IDENTIFIER    

radConverters 1.3.6.1.4.1.164.5
OBJECT IDENTIFIER    

radGen 1.3.6.1.4.1.164.6
OBJECT IDENTIFIER    

radStkHub 1.3.6.1.4.1.164.7
OBJECT IDENTIFIER    

radAtm 1.3.6.1.4.1.164.12
OBJECT IDENTIFIER    

radRouter 1.3.6.1.4.1.164.11
OBJECT IDENTIFIER    

rtrBridge 1.3.6.1.4.1.164.11.7
OBJECT IDENTIFIER    

systems 1.3.6.1.4.1.164.6.1
OBJECT IDENTIFIER    

radSysTR 1.3.6.1.4.1.164.6.1.1
OBJECT IDENTIFIER    

radRADring 1.3.6.1.4.1.164.6.1.1.1
OBJECT IDENTIFIER    

radTMA 1.3.6.1.4.1.164.6.1.1.2
OBJECT IDENTIFIER    

radRingMonitor 1.3.6.1.4.1.164.6.1.1.3
OBJECT IDENTIFIER    

radSysFddi 1.3.6.1.4.1.164.6.1.2
OBJECT IDENTIFIER    

radFDX100 1.3.6.1.4.1.164.6.1.2.1
OBJECT IDENTIFIER    

radSysWan 1.3.6.1.4.1.164.6.1.3
OBJECT IDENTIFIER    

radSysWanEvents 1.3.6.1.4.1.164.6.1.3.0
The events for RAD Wan products.
Status: current Access: read-only
OBJECT-IDENTITY    

radMP2100 1.3.6.1.4.1.164.6.1.3.1
OBJECT IDENTIFIER    

radMP2104 1.3.6.1.4.1.164.6.1.3.2
OBJECT IDENTIFIER    

radMP2100B 1.3.6.1.4.1.164.6.1.3.3
OBJECT IDENTIFIER    

radMP2100F 1.3.6.1.4.1.164.6.1.3.4
OBJECT IDENTIFIER    

radMP2100H 1.3.6.1.4.1.164.6.1.3.5
OBJECT IDENTIFIER    

radMP2104H 1.3.6.1.4.1.164.6.1.3.6
OBJECT IDENTIFIER    

radMP2200B 1.3.6.1.4.1.164.6.1.3.7
OBJECT IDENTIFIER    

radMP2200F 1.3.6.1.4.1.164.6.1.3.8
OBJECT IDENTIFIER    

radMX3000 1.3.6.1.4.1.164.6.1.3.9
OBJECT IDENTIFIER    

radMX3004 1.3.6.1.4.1.164.6.1.3.10
OBJECT IDENTIFIER    

radMX30 1.3.6.1.4.1.164.6.1.3.11
OBJECT IDENTIFIER    

radMX300 1.3.6.1.4.1.164.6.1.3.12
OBJECT IDENTIFIER    

radVOIP 1.3.6.1.4.1.164.6.1.3.13
OBJECT IDENTIFIER    

radKM2100 1.3.6.1.4.1.164.6.1.3.15
OBJECT IDENTIFIER    

radKM2104 1.3.6.1.4.1.164.6.1.3.16
OBJECT IDENTIFIER    

radDXC30 1.3.6.1.4.1.164.6.1.3.20
OBJECT IDENTIFIER    

radDXC10A 1.3.6.1.4.1.164.6.1.3.21
OBJECT IDENTIFIER    

radDXC8R 1.3.6.1.4.1.164.6.1.3.22
OBJECT IDENTIFIER    

radDXC30E 1.3.6.1.4.1.164.6.1.3.23
OBJECT IDENTIFIER    

radDXC3000 1.3.6.1.4.1.164.6.1.3.24
OBJECT IDENTIFIER    

radDXC8RNew 1.3.6.1.4.1.164.6.1.3.25
OBJECT IDENTIFIER    

radFcdT1LC 1.3.6.1.4.1.164.6.1.3.26
OBJECT IDENTIFIER    

radFcdE1LC 1.3.6.1.4.1.164.6.1.3.27
OBJECT IDENTIFIER    

radFcdT1L 1.3.6.1.4.1.164.6.1.3.28
OBJECT IDENTIFIER    

radFcdE1L 1.3.6.1.4.1.164.6.1.3.29
OBJECT IDENTIFIER    

radFcdT1 1.3.6.1.4.1.164.6.1.3.30
OBJECT IDENTIFIER    

radFcdE1 1.3.6.1.4.1.164.6.1.3.31
OBJECT IDENTIFIER    

radFcdE1I 1.3.6.1.4.1.164.6.1.3.32
OBJECT IDENTIFIER    

radFcdT1M 1.3.6.1.4.1.164.6.1.3.33
OBJECT IDENTIFIER    

radFcdE1M 1.3.6.1.4.1.164.6.1.3.34
OBJECT IDENTIFIER    

radFcdIP 1.3.6.1.4.1.164.6.1.3.35
OBJECT IDENTIFIER    

radFcdT1A 1.3.6.1.4.1.164.6.1.3.36
OBJECT IDENTIFIER    

radFcdE1A 1.3.6.1.4.1.164.6.1.3.37
OBJECT IDENTIFIER    

radFcdW 1.3.6.1.4.1.164.6.1.3.38
OBJECT IDENTIFIER    

radFcdSTM 1.3.6.1.4.1.164.6.1.3.39
OBJECT IDENTIFIER    

radHtuE1Sa 1.3.6.1.4.1.164.6.1.3.40
OBJECT IDENTIFIER    

radHtuE1 1.3.6.1.4.1.164.6.1.3.41
OBJECT IDENTIFIER    

radHtu2Sa 1.3.6.1.4.1.164.6.1.3.42
OBJECT IDENTIFIER    

radHtu2 1.3.6.1.4.1.164.6.1.3.43
OBJECT IDENTIFIER    

radAsmi450R768Sa 1.3.6.1.4.1.164.6.1.3.44
OBJECT IDENTIFIER    

radAsmi450R768 1.3.6.1.4.1.164.6.1.3.45
OBJECT IDENTIFIER    

radAsmi450R1152Sa 1.3.6.1.4.1.164.6.1.3.46
OBJECT IDENTIFIER    

radAsmi450R1152 1.3.6.1.4.1.164.6.1.3.47
OBJECT IDENTIFIER    

radLrs12F 1.3.6.1.4.1.164.6.1.3.48
OBJECT IDENTIFIER    

radLrs12B 1.3.6.1.4.1.164.6.1.3.49
OBJECT IDENTIFIER    

radLrs52 1.3.6.1.4.1.164.6.1.3.50
OBJECT IDENTIFIER    

radHcdE1Sa 1.3.6.1.4.1.164.6.1.3.51
OBJECT IDENTIFIER    

radHcdE1 1.3.6.1.4.1.164.6.1.3.52
OBJECT IDENTIFIER    

radHtuT1Sa 1.3.6.1.4.1.164.6.1.3.53
OBJECT IDENTIFIER    

radHtuT1 1.3.6.1.4.1.164.6.1.3.54
OBJECT IDENTIFIER    

radOptimux4E1 1.3.6.1.4.1.164.6.1.3.55
OBJECT IDENTIFIER    

radOptimux4T1 1.3.6.1.4.1.164.6.1.3.56
OBJECT IDENTIFIER    

radOptimuxXLE1 1.3.6.1.4.1.164.6.1.3.57
OBJECT IDENTIFIER    

radOptimuxXLT1 1.3.6.1.4.1.164.6.1.3.58
OBJECT IDENTIFIER    

radOptimuxXL16E1 1.3.6.1.4.1.164.6.1.3.59
OBJECT IDENTIFIER    

radImx64 1.3.6.1.4.1.164.6.1.3.60
OBJECT IDENTIFIER    

radImx6L 1.3.6.1.4.1.164.6.1.3.61
OBJECT IDENTIFIER    

radImx2 1.3.6.1.4.1.164.6.1.3.62
OBJECT IDENTIFIER    

radImx4T1 1.3.6.1.4.1.164.6.1.3.63
OBJECT IDENTIFIER    

radImx4E1 1.3.6.1.4.1.164.6.1.3.64
OBJECT IDENTIFIER    

radImx2T1E1 1.3.6.1.4.1.164.6.1.3.65
OBJECT IDENTIFIER    

radImxi4 1.3.6.1.4.1.164.6.1.3.66
OBJECT IDENTIFIER    

radOptimux155 1.3.6.1.4.1.164.6.1.3.67
OBJECT IDENTIFIER    

radOptimux4T1L 1.3.6.1.4.1.164.6.1.3.68
OBJECT IDENTIFIER    

radOptimux4E1L 1.3.6.1.4.1.164.6.1.3.69
OBJECT IDENTIFIER    

radHtuE1SaV2 1.3.6.1.4.1.164.6.1.3.70
OBJECT IDENTIFIER    

radHtuE1V2 1.3.6.1.4.1.164.6.1.3.71
OBJECT IDENTIFIER    

radFomiE3 1.3.6.1.4.1.164.6.1.3.72
OBJECT IDENTIFIER    

radFomiT3 1.3.6.1.4.1.164.6.1.3.73
OBJECT IDENTIFIER    

radOpt4E1C 1.3.6.1.4.1.164.6.1.3.74
OBJECT IDENTIFIER    

radOpt4T1C 1.3.6.1.4.1.164.6.1.3.75
OBJECT IDENTIFIER    

radPrbiE3 1.3.6.1.4.1.164.6.1.3.76
OBJECT IDENTIFIER    

radPrbiT3 1.3.6.1.4.1.164.6.1.3.77
OBJECT IDENTIFIER    

radHcd4Sa 1.3.6.1.4.1.164.6.1.3.78
OBJECT IDENTIFIER    

radOptimuxT3 1.3.6.1.4.1.164.6.1.3.79
OBJECT IDENTIFIER    

radFRmon 1.3.6.1.4.1.164.6.1.3.80
OBJECT IDENTIFIER    

radIpMux4 1.3.6.1.4.1.164.6.1.3.81
OBJECT IDENTIFIER    

radIpMux1 1.3.6.1.4.1.164.6.1.3.82
OBJECT IDENTIFIER    

radIpMux16 1.3.6.1.4.1.164.6.1.3.83
OBJECT IDENTIFIER    

radIpMux1E 1.3.6.1.4.1.164.6.1.3.84
OBJECT IDENTIFIER    

radVmux2100 1.3.6.1.4.1.164.6.1.3.85
OBJECT IDENTIFIER    

radMP104 1.3.6.1.4.1.164.6.1.3.86
OBJECT IDENTIFIER    

radMP204 1.3.6.1.4.1.164.6.1.3.87
OBJECT IDENTIFIER    

radVmux110 1.3.6.1.4.1.164.6.1.3.88
OBJECT IDENTIFIER    

radFcd155 1.3.6.1.4.1.164.6.1.3.90
OBJECT IDENTIFIER    

radIpMux8 1.3.6.1.4.1.164.6.1.3.91
OBJECT IDENTIFIER    

radOptimux155DS3 1.3.6.1.4.1.164.6.1.3.92
OBJECT IDENTIFIER    

radOptimuxT3L 1.3.6.1.4.1.164.6.1.3.93
OBJECT IDENTIFIER    

radGmux2000 1.3.6.1.4.1.164.6.1.3.94
OBJECT IDENTIFIER    

radOp16E1L 1.3.6.1.4.1.164.6.1.3.95
OBJECT IDENTIFIER    

radOp16E1LS 1.3.6.1.4.1.164.6.1.3.96
OBJECT IDENTIFIER    

radPRBm20 1.3.6.1.4.1.164.6.1.3.97
OBJECT IDENTIFIER    

radPRBm22 1.3.6.1.4.1.164.6.1.3.98
OBJECT IDENTIFIER    

radAsmi52A 1.3.6.1.4.1.164.6.1.3.99
OBJECT IDENTIFIER    

radOpXLE1 1.3.6.1.4.1.164.6.1.3.100
OBJECT IDENTIFIER    

radOpXLT1 1.3.6.1.4.1.164.6.1.3.101
OBJECT IDENTIFIER    

radOpXL16E1 1.3.6.1.4.1.164.6.1.3.102
OBJECT IDENTIFIER    

radOp4E1 1.3.6.1.4.1.164.6.1.3.103
OBJECT IDENTIFIER    

radOp4T1 1.3.6.1.4.1.164.6.1.3.104
OBJECT IDENTIFIER    

radDxc4 1.3.6.1.4.1.164.6.1.3.105
OBJECT IDENTIFIER    

radIpMux11 1.3.6.1.4.1.164.6.1.3.106
OBJECT IDENTIFIER    

radIpMux14 1.3.6.1.4.1.164.6.1.3.107
OBJECT IDENTIFIER    

radOp1550 1.3.6.1.4.1.164.6.1.3.108
OBJECT IDENTIFIER    

radFdsl101 1.3.6.1.4.1.164.6.1.3.110
OBJECT IDENTIFIER    

radFdsl201 1.3.6.1.4.1.164.6.1.3.111
OBJECT IDENTIFIER    

radVmux120 1.3.6.1.4.1.164.6.1.3.112
OBJECT IDENTIFIER    

radVmux2200 1.3.6.1.4.1.164.6.1.3.113
OBJECT IDENTIFIER    

radVmux400 1.3.6.1.4.1.164.6.1.3.114
OBJECT IDENTIFIER    

radIpMux116 1.3.6.1.4.1.164.6.1.3.115
OBJECT IDENTIFIER    

radOp4E1LNew 1.3.6.1.4.1.164.6.1.3.116
OBJECT IDENTIFIER    

radOp4T1LNew 1.3.6.1.4.1.164.6.1.3.117
OBJECT IDENTIFIER    

radFcd155E 1.3.6.1.4.1.164.6.1.3.118
OBJECT IDENTIFIER    

radFcd155ES 1.3.6.1.4.1.164.6.1.3.119
OBJECT IDENTIFIER    

radMP4100 1.3.6.1.4.1.164.6.1.3.120
OBJECT IDENTIFIER    

radAsmi52L 1.3.6.1.4.1.164.6.1.3.121
OBJECT IDENTIFIER    

radVmux210 1.3.6.1.4.1.164.6.1.3.122
OBJECT IDENTIFIER    

radOp34E1 1.3.6.1.4.1.164.6.1.3.123
OBJECT IDENTIFIER    

radVmux312 1.3.6.1.4.1.164.6.1.3.124
OBJECT IDENTIFIER    

radVmux404 1.3.6.1.4.1.164.6.1.3.125
OBJECT IDENTIFIER    

radVmux420 1.3.6.1.4.1.164.6.1.3.126
OBJECT IDENTIFIER    

radIpMux12 1.3.6.1.4.1.164.6.1.3.127
OBJECT IDENTIFIER    

radOptimux4E1V3dot5 1.3.6.1.4.1.164.6.1.3.128
OBJECT IDENTIFIER    

radOptimux4E1Mar06 1.3.6.1.4.1.164.6.1.3.129
OBJECT IDENTIFIER    

radFcd155EwAPS 1.3.6.1.4.1.164.6.1.3.130
OBJECT IDENTIFIER    

radOptimux4T1Mar06 1.3.6.1.4.1.164.6.1.3.131
OBJECT IDENTIFIER    

radFcd155EwAPS2pdh 1.3.6.1.4.1.164.6.1.3.132
OBJECT IDENTIFIER    

radVmux320 1.3.6.1.4.1.164.6.1.3.133
OBJECT IDENTIFIER    

radMP2100VoIP 1.3.6.1.4.1.164.6.1.3.134
OBJECT IDENTIFIER    

radMP2104VoIP 1.3.6.1.4.1.164.6.1.3.135
OBJECT IDENTIFIER    

radIpMux24 1.3.6.1.4.1.164.6.1.3.136
OBJECT IDENTIFIER    

radOp4E1NG1 1.3.6.1.4.1.164.6.1.3.137
OBJECT IDENTIFIER    

radOp4T1NG1 1.3.6.1.4.1.164.6.1.3.138
OBJECT IDENTIFIER    

radOp25 1.3.6.1.4.1.164.6.1.3.139
OBJECT IDENTIFIER    

radAsmi54 1.3.6.1.4.1.164.6.1.3.140
OBJECT IDENTIFIER    

radVmux314 1.3.6.1.4.1.164.6.1.3.141
OBJECT IDENTIFIER    

radFcd622 1.3.6.1.4.1.164.6.1.3.142
OBJECT IDENTIFIER    

radLrs22 1.3.6.1.4.1.164.6.1.3.143
OBJECT IDENTIFIER    

radUNT20E1 1.3.6.1.4.1.164.6.1.3.144
OBJECT IDENTIFIER    

radIpMux2L 1.3.6.1.4.1.164.6.1.3.145
OBJECT IDENTIFIER    

radUNT20Fcd 1.3.6.1.4.1.164.6.1.3.146
OBJECT IDENTIFIER    

radIpMux216 1.3.6.1.4.1.164.6.1.3.147
OBJECT IDENTIFIER    

radLrs102 1.3.6.1.4.1.164.6.1.3.148
OBJECT IDENTIFIER    

radGmux2004 1.3.6.1.4.1.164.6.1.3.149
OBJECT IDENTIFIER    

radLrs102unbal 1.3.6.1.4.1.164.6.1.3.150
OBJECT IDENTIFIER    

radLrs16 1.3.6.1.4.1.164.6.1.3.151
OBJECT IDENTIFIER    

radVmux405 1.3.6.1.4.1.164.6.1.3.152
OBJECT IDENTIFIER    

radVmux425 1.3.6.1.4.1.164.6.1.3.153
OBJECT IDENTIFIER    

radMiniCVS 1.3.6.1.4.1.164.6.1.3.154
OBJECT IDENTIFIER    

radSysBRG 1.3.6.1.4.1.164.6.1.4
OBJECT IDENTIFIER    

radTRE1 1.3.6.1.4.1.164.6.1.4.1
OBJECT IDENTIFIER    

radTRE1D 1.3.6.1.4.1.164.6.1.4.2
OBJECT IDENTIFIER    

radTRE8 1.3.6.1.4.1.164.6.1.4.3
OBJECT IDENTIFIER    

radTRE8D 1.3.6.1.4.1.164.6.1.4.4
OBJECT IDENTIFIER    

radMBE1 1.3.6.1.4.1.164.6.1.4.5
OBJECT IDENTIFIER    

radMBE1D 1.3.6.1.4.1.164.6.1.4.6
OBJECT IDENTIFIER    

radMBE8 1.3.6.1.4.1.164.6.1.4.7
OBJECT IDENTIFIER    

radMBE8D 1.3.6.1.4.1.164.6.1.4.8
OBJECT IDENTIFIER    

radMLBT 1.3.6.1.4.1.164.6.1.4.9
OBJECT IDENTIFIER    

radFEB4DAS 1.3.6.1.4.1.164.6.1.4.10
OBJECT IDENTIFIER    

radTrimBrg10 1.3.6.1.4.1.164.6.1.4.11
OBJECT IDENTIFIER    

radTrimBrg16 1.3.6.1.4.1.164.6.1.4.12
OBJECT IDENTIFIER    

radRRTRE8 1.3.6.1.4.1.164.6.1.4.13
OBJECT IDENTIFIER    

radRRTRE8D 1.3.6.1.4.1.164.6.1.4.14
OBJECT IDENTIFIER    

radRRMLBT 1.3.6.1.4.1.164.6.1.4.15
OBJECT IDENTIFIER    

radRRMLBTF 1.3.6.1.4.1.164.6.1.4.16
OBJECT IDENTIFIER    

radRRTRE1D 1.3.6.1.4.1.164.6.1.4.17
OBJECT IDENTIFIER    

radTRERAS 1.3.6.1.4.1.164.6.1.4.18
OBJECT IDENTIFIER    

radTRERASa 1.3.6.1.4.1.164.6.1.4.19
OBJECT IDENTIFIER    

radMBERAS 1.3.6.1.4.1.164.6.1.4.20
OBJECT IDENTIFIER    

radMBERASa 1.3.6.1.4.1.164.6.1.4.21
OBJECT IDENTIFIER    

radFEB4FDX 1.3.6.1.4.1.164.6.1.4.22
OBJECT IDENTIFIER    

radFEB4SAS 1.3.6.1.4.1.164.6.1.4.23
OBJECT IDENTIFIER    

radRRFTBDAS 1.3.6.1.4.1.164.6.1.4.24
OBJECT IDENTIFIER    

radRRFTBSAS 1.3.6.1.4.1.164.6.1.4.25
OBJECT IDENTIFIER    

radFTBDAS 1.3.6.1.4.1.164.6.1.4.26
OBJECT IDENTIFIER    

radFTBSAS 1.3.6.1.4.1.164.6.1.4.27
OBJECT IDENTIFIER    

radFastWay100 1.3.6.1.4.1.164.6.1.4.28
OBJECT IDENTIFIER    

radSysCnvrtr 1.3.6.1.4.1.164.6.1.5
OBJECT IDENTIFIER    

radSTC1 1.3.6.1.4.1.164.6.1.5.1
OBJECT IDENTIFIER    

radSTC2 1.3.6.1.4.1.164.6.1.5.3
OBJECT IDENTIFIER    

radSTC1UDP 1.3.6.1.4.1.164.6.1.5.4
OBJECT IDENTIFIER    

radSTC2UDP 1.3.6.1.4.1.164.6.1.5.6
OBJECT IDENTIFIER    

radFTC1 1.3.6.1.4.1.164.6.1.5.10
OBJECT IDENTIFIER    

radFTC2 1.3.6.1.4.1.164.6.1.5.12
OBJECT IDENTIFIER    

radFTC1UDP 1.3.6.1.4.1.164.6.1.5.13
OBJECT IDENTIFIER    

radFTC2UDP 1.3.6.1.4.1.164.6.1.5.15
OBJECT IDENTIFIER    

radSEC1 1.3.6.1.4.1.164.6.1.5.20
OBJECT IDENTIFIER    

radSEC2 1.3.6.1.4.1.164.6.1.5.22
OBJECT IDENTIFIER    

radSEC1UDP 1.3.6.1.4.1.164.6.1.5.23
OBJECT IDENTIFIER    

radSEC2UDP 1.3.6.1.4.1.164.6.1.5.25
OBJECT IDENTIFIER    

radFEC1 1.3.6.1.4.1.164.6.1.5.30
OBJECT IDENTIFIER    

radFEC2 1.3.6.1.4.1.164.6.1.5.32
OBJECT IDENTIFIER    

radFEC1UDP 1.3.6.1.4.1.164.6.1.5.33
OBJECT IDENTIFIER    

radFEC2UDP 1.3.6.1.4.1.164.6.1.5.35
OBJECT IDENTIFIER    

radRIC155 1.3.6.1.4.1.164.6.1.5.36
OBJECT IDENTIFIER    

radRICE1 1.3.6.1.4.1.164.6.1.5.37
OBJECT IDENTIFIER    

radETX102 1.3.6.1.4.1.164.6.1.5.38
OBJECT IDENTIFIER    

radRIC155GE 1.3.6.1.4.1.164.6.1.5.39
OBJECT IDENTIFIER    

radRiciT3 1.3.6.1.4.1.164.6.1.5.40
OBJECT IDENTIFIER    

radRiciE3 1.3.6.1.4.1.164.6.1.5.41
OBJECT IDENTIFIER    

radRiciT1 1.3.6.1.4.1.164.6.1.5.42
OBJECT IDENTIFIER    

radETX202 1.3.6.1.4.1.164.6.1.5.43
OBJECT IDENTIFIER    

radETX105 1.3.6.1.4.1.164.6.1.5.44
OBJECT IDENTIFIER    

radETX205 1.3.6.1.4.1.164.6.1.5.45
OBJECT IDENTIFIER    

radRiciSE 1.3.6.1.4.1.164.6.1.5.46
OBJECT IDENTIFIER    

radRIC622GE 1.3.6.1.4.1.164.6.1.5.47
OBJECT IDENTIFIER    

radSPH 1.3.6.1.4.1.164.6.1.5.48
OBJECT IDENTIFIER    

radMiricE1T1 1.3.6.1.4.1.164.6.1.5.49
OBJECT IDENTIFIER    

radMiricE3T3 1.3.6.1.4.1.164.6.1.5.50
OBJECT IDENTIFIER    

radEthAccess 1.3.6.1.4.1.164.6.1.6
OBJECT IDENTIFIER    

radETX510 1.3.6.1.4.1.164.6.1.6.1
OBJECT IDENTIFIER    

radEGate100 1.3.6.1.4.1.164.6.1.6.2
OBJECT IDENTIFIER    

radEGate20 1.3.6.1.4.1.164.6.1.6.3
OBJECT IDENTIFIER    

radRici8E1 1.3.6.1.4.1.164.6.1.6.4
OBJECT IDENTIFIER    

radRici8T1 1.3.6.1.4.1.164.6.1.6.5
OBJECT IDENTIFIER    

radRici4E1 1.3.6.1.4.1.164.6.1.6.6
OBJECT IDENTIFIER    

radRici4T1 1.3.6.1.4.1.164.6.1.6.7
OBJECT IDENTIFIER    

radIMXI4 1.3.6.1.4.1.164.6.1.6.8
OBJECT IDENTIFIER    

radETX550 1.3.6.1.4.1.164.6.1.6.9
OBJECT IDENTIFIER    

radRici16 1.3.6.1.4.1.164.6.1.6.10
OBJECT IDENTIFIER    

radETX102A 1.3.6.1.4.1.164.6.1.6.11
OBJECT IDENTIFIER    

radETX202A 1.3.6.1.4.1.164.6.1.6.12
OBJECT IDENTIFIER    

radETX201A 1.3.6.1.4.1.164.6.1.6.13
OBJECT IDENTIFIER    

radETX201 1.3.6.1.4.1.164.6.1.6.14
OBJECT IDENTIFIER    

radUNT20Ric 1.3.6.1.4.1.164.6.1.6.15
OBJECT IDENTIFIER    

radRici4E1L 1.3.6.1.4.1.164.6.1.6.16
OBJECT IDENTIFIER    

radRici8E1L 1.3.6.1.4.1.164.6.1.6.17
OBJECT IDENTIFIER    

radRici155GE 1.3.6.1.4.1.164.6.1.6.18
OBJECT IDENTIFIER    

radRici622GE 1.3.6.1.4.1.164.6.1.6.19
OBJECT IDENTIFIER    

radETX208 1.3.6.1.4.1.164.6.1.6.20
OBJECT IDENTIFIER    

radETX202AW 1.3.6.1.4.1.164.6.1.6.21
OBJECT IDENTIFIER    

radETX102H 1.3.6.1.4.1.164.6.1.6.22
OBJECT IDENTIFIER    

radETX202H 1.3.6.1.4.1.164.6.1.6.23
OBJECT IDENTIFIER    

radSysStkHub 1.3.6.1.4.1.164.6.1.7
OBJECT IDENTIFIER    

radRBHE 1.3.6.1.4.1.164.6.1.7.1
OBJECT IDENTIFIER    

radRBHT 1.3.6.1.4.1.164.6.1.7.2
OBJECT IDENTIFIER    

radRBHEEvents 1.3.6.1.4.1.164.6.1.7.1.0
The events for RAD Stackable products.
Status: current Access: read-only
OBJECT-IDENTITY    

radRBHTEvents 1.3.6.1.4.1.164.6.1.7.2.0
The events for RAD Stackable products.
Status: current Access: read-only
OBJECT-IDENTITY    

radETS4fddiDAS 1.3.6.1.4.1.164.6.1.7.3
OBJECT IDENTIFIER    

radETS4fddiSAS 1.3.6.1.4.1.164.6.1.7.4
OBJECT IDENTIFIER    

radSAHEMX 1.3.6.1.4.1.164.6.1.7.5
OBJECT IDENTIFIER    

radSAHTM 1.3.6.1.4.1.164.6.1.7.6
OBJECT IDENTIFIER    

radETS4 1.3.6.1.4.1.164.6.1.7.7
OBJECT IDENTIFIER    

radSAHEMU 1.3.6.1.4.1.164.6.1.7.8
OBJECT IDENTIFIER    

unknown 1.3.6.1.4.1.164.6.1.7.9
OBJECT IDENTIFIER    

radSAH16Eint 1.3.6.1.4.1.164.6.1.7.10
OBJECT IDENTIFIER    

radSAH16Tint 1.3.6.1.4.1.164.6.1.7.11
OBJECT IDENTIFIER    

radSAH16Eext 1.3.6.1.4.1.164.6.1.7.12
OBJECT IDENTIFIER    

radSAH16Text 1.3.6.1.4.1.164.6.1.7.13
OBJECT IDENTIFIER    

radSysPS 1.3.6.1.4.1.164.6.1.8
OBJECT IDENTIFIER    

radSysPSEvents 1.3.6.1.4.1.164.6.1.8.0
The events for RAD Packet Switch (PS) products.
Status: current Access: read-only
OBJECT-IDENTITY    

radSPS2 1.3.6.1.4.1.164.6.1.8.1
OBJECT IDENTIFIER    

radSPS3 1.3.6.1.4.1.164.6.1.8.2
OBJECT IDENTIFIER    

radSPS6 1.3.6.1.4.1.164.6.1.8.3
OBJECT IDENTIFIER    

radSPS9 1.3.6.1.4.1.164.6.1.8.4
OBJECT IDENTIFIER    

radSPS12 1.3.6.1.4.1.164.6.1.8.5
OBJECT IDENTIFIER    

radAPD2 1.3.6.1.4.1.164.6.1.8.6
OBJECT IDENTIFIER    

radAPD8 1.3.6.1.4.1.164.6.1.8.7
OBJECT IDENTIFIER    

radAPS8 1.3.6.1.4.1.164.6.1.8.8
OBJECT IDENTIFIER    

radAPS16 1.3.6.1.4.1.164.6.1.8.9
OBJECT IDENTIFIER    

radAPS24 1.3.6.1.4.1.164.6.1.8.10
OBJECT IDENTIFIER    

radSPS3S 1.3.6.1.4.1.164.6.1.8.11
OBJECT IDENTIFIER    

radFPS8 1.3.6.1.4.1.164.6.1.8.12
OBJECT IDENTIFIER    

radFPS12 1.3.6.1.4.1.164.6.1.8.13
OBJECT IDENTIFIER    

radSPS3ScSL 1.3.6.1.4.1.164.6.1.8.14
OBJECT IDENTIFIER    

radSPS3Sc2S 1.3.6.1.4.1.164.6.1.8.15
OBJECT IDENTIFIER    

radFPS8c 1.3.6.1.4.1.164.6.1.8.16
OBJECT IDENTIFIER    

radFPS4 1.3.6.1.4.1.164.6.1.8.17
OBJECT IDENTIFIER    

radSPS4 1.3.6.1.4.1.164.6.1.8.18
OBJECT IDENTIFIER    

radSysEth 1.3.6.1.4.1.164.6.1.9
OBJECT IDENTIFIER    

radEP8T 1.3.6.1.4.1.164.6.1.9.1
OBJECT IDENTIFIER    

radEP4TAUI 1.3.6.1.4.1.164.6.1.9.2
OBJECT IDENTIFIER    

radEP4T2FL 1.3.6.1.4.1.164.6.1.9.3
OBJECT IDENTIFIER    

radEP4TFL 1.3.6.1.4.1.164.6.1.9.4
OBJECT IDENTIFIER    

radEP4FL 1.3.6.1.4.1.164.6.1.9.5
OBJECT IDENTIFIER    

radEPR8T 1.3.6.1.4.1.164.6.1.9.7
OBJECT IDENTIFIER    

radEPR4TAUI 1.3.6.1.4.1.164.6.1.9.8
OBJECT IDENTIFIER    

radEPR4T2FL 1.3.6.1.4.1.164.6.1.9.9
OBJECT IDENTIFIER    

radEPR4TFL 1.3.6.1.4.1.164.6.1.9.10
OBJECT IDENTIFIER    

radEPR4FL 1.3.6.1.4.1.164.6.1.9.11
OBJECT IDENTIFIER    

radSysRtr 1.3.6.1.4.1.164.6.1.11
OBJECT IDENTIFIER    

radSysRtrEvents 1.3.6.1.4.1.164.6.1.11.0
The events for RAD Router products.
Status: current Access: read-only
OBJECT-IDENTITY    

radRTED 1.3.6.1.4.1.164.6.1.11.1
OBJECT IDENTIFIER    

radRTEM 1.3.6.1.4.1.164.6.1.11.2
OBJECT IDENTIFIER    

radRTEC 1.3.6.1.4.1.164.6.1.11.3
OBJECT IDENTIFIER    

radWebRanger 1.3.6.1.4.1.164.6.1.11.4
OBJECT IDENTIFIER    

radTinyRouter 1.3.6.1.4.1.164.6.1.11.5
OBJECT IDENTIFIER    

radLA240 1.3.6.1.4.1.164.6.1.11.6
OBJECT IDENTIFIER    

radSuperLan 1.3.6.1.4.1.164.6.1.11.7
OBJECT IDENTIFIER    

radLA240I 1.3.6.1.4.1.164.6.1.11.8
OBJECT IDENTIFIER    

radFcdIsdn 1.3.6.1.4.1.164.6.1.11.9
OBJECT IDENTIFIER    

radEFcdIp 1.3.6.1.4.1.164.6.1.11.10
OBJECT IDENTIFIER    

radFcdIpD 1.3.6.1.4.1.164.6.1.11.11
OBJECT IDENTIFIER    

radFcdIpM 1.3.6.1.4.1.164.6.1.11.12
OBJECT IDENTIFIER    

radFcdIpL 1.3.6.1.4.1.164.6.1.11.13
OBJECT IDENTIFIER    

radSysAtm 1.3.6.1.4.1.164.6.1.12
OBJECT IDENTIFIER    

radSysAtmEvents 1.3.6.1.4.1.164.6.1.12.0
The events for RAD ATM products.
Status: current Access: read-only
OBJECT-IDENTITY    

radStarSwitch 1.3.6.1.4.1.164.6.1.12.1
OBJECT IDENTIFIER    

radStarSwitchATM25 1.3.6.1.4.1.164.6.1.12.1.1
OBJECT IDENTIFIER    

radStarSwitchATM25L 1.3.6.1.4.1.164.6.1.12.1.2
OBJECT IDENTIFIER    

radStarSwitchATM155 1.3.6.1.4.1.164.6.1.12.1.3
OBJECT IDENTIFIER    

radAtmCsuDsu 1.3.6.1.4.1.164.6.1.12.2
OBJECT IDENTIFIER    

radAmcdE1 1.3.6.1.4.1.164.6.1.12.2.1
OBJECT IDENTIFIER    

radAmcdT1 1.3.6.1.4.1.164.6.1.12.2.2
OBJECT IDENTIFIER    

radAce20E 1.3.6.1.4.1.164.6.1.12.2.3
OBJECT IDENTIFIER    

radAce20T 1.3.6.1.4.1.164.6.1.12.2.4
OBJECT IDENTIFIER    

radAce2005 1.3.6.1.4.1.164.6.1.12.2.5
OBJECT IDENTIFIER    

radAce2002 1.3.6.1.4.1.164.6.1.12.2.6
OBJECT IDENTIFIER    

radAce2002E 1.3.6.1.4.1.164.6.1.12.2.7
OBJECT IDENTIFIER    

radAce2E 1.3.6.1.4.1.164.6.1.12.2.8
OBJECT IDENTIFIER    

radAce2T 1.3.6.1.4.1.164.6.1.12.2.9
OBJECT IDENTIFIER    

radMlAtmE1 1.3.6.1.4.1.164.6.1.12.2.10
OBJECT IDENTIFIER    

radMlAtmT1 1.3.6.1.4.1.164.6.1.12.2.11
OBJECT IDENTIFIER    

radAmc102 1.3.6.1.4.1.164.6.1.12.2.12
OBJECT IDENTIFIER    

radAmc102c 1.3.6.1.4.1.164.6.1.12.2.13
OBJECT IDENTIFIER    

radAce202 1.3.6.1.4.1.164.6.1.12.2.14
OBJECT IDENTIFIER    

radAce 1.3.6.1.4.1.164.6.1.12.3
OBJECT IDENTIFIER    

radAce101 1.3.6.1.4.1.164.6.1.12.3.1
OBJECT IDENTIFIER    

radAce102 1.3.6.1.4.1.164.6.1.12.3.2
OBJECT IDENTIFIER    

radAce50 1.3.6.1.4.1.164.6.1.12.3.3
OBJECT IDENTIFIER    

radAce52 1.3.6.1.4.1.164.6.1.12.3.4
OBJECT IDENTIFIER    

radAce52L 1.3.6.1.4.1.164.6.1.12.3.5
OBJECT IDENTIFIER    

radAce201 1.3.6.1.4.1.164.6.1.12.3.7
OBJECT IDENTIFIER    

radAce3200 1.3.6.1.4.1.164.6.1.12.3.8
OBJECT IDENTIFIER    

radAce3100 1.3.6.1.4.1.164.6.1.12.3.9
OBJECT IDENTIFIER    

radAce3400 1.3.6.1.4.1.164.6.1.12.3.10
OBJECT IDENTIFIER    

radAce3402 1.3.6.1.4.1.164.6.1.12.3.11
OBJECT IDENTIFIER    

radAce3100PSN 1.3.6.1.4.1.164.6.1.12.3.12
OBJECT IDENTIFIER    

radAce3200PSN 1.3.6.1.4.1.164.6.1.12.3.13
OBJECT IDENTIFIER    

radAce3400PSN 1.3.6.1.4.1.164.6.1.12.3.14
OBJECT IDENTIFIER    

radAce3402PSN 1.3.6.1.4.1.164.6.1.12.3.15
OBJECT IDENTIFIER    

radAce3600 1.3.6.1.4.1.164.6.1.12.3.16
OBJECT IDENTIFIER    

radAce3205 1.3.6.1.4.1.164.6.1.12.3.17
OBJECT IDENTIFIER    

radAce3105 1.3.6.1.4.1.164.6.1.12.3.18
OBJECT IDENTIFIER    

radSysLA 1.3.6.1.4.1.164.6.1.13
OBJECT IDENTIFIER    

radLA140 1.3.6.1.4.1.164.6.1.13.1
OBJECT IDENTIFIER    

radLA110 1.3.6.1.4.1.164.6.1.13.2
OBJECT IDENTIFIER    

radLA104 1.3.6.1.4.1.164.6.1.13.3
OBJECT IDENTIFIER    

radLA130 1.3.6.1.4.1.164.6.1.13.4
OBJECT IDENTIFIER    

radLA210 1.3.6.1.4.1.164.6.1.13.5
OBJECT IDENTIFIER    

radSysTerminal 1.3.6.1.4.1.164.6.1.100
OBJECT IDENTIFIER    

agnt 1.3.6.1.4.1.164.6.2
OBJECT IDENTIFIER    

agnHwVersion 1.3.6.1.4.1.164.6.2.1
ASCII string for description and display of the agent hardware version, as it is known by the agent software.The user can update the version upon request when he changes components in the agent's module
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

agnTrapMask 1.3.6.1.4.1.164.6.2.2
The value of this attribute determines the type of traps the agent should mask and not send to the management console. The value is differently determined for different products. There are mainly two methods: - an integer number, specifying the traps' severity. - a sum of 2**n, where n is a bit assigned to a certain masked trap group. User should consult the product specification, to find out the method employed.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

agnTrapValue 1.3.6.1.4.1.164.6.2.3
The value of the trap decoded in internal RAD format. Full description is given in the Trap definition file
Status: deprecated Access: read-only
OBJECT-TYPE    
  OCTET STRING  

agnChangeCnt 1.3.6.1.4.1.164.6.2.4
The number of changes in system configuration that were reported to the manager since last cold start
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

agnSpecific 1.3.6.1.4.1.164.6.2.5
Object identifier of entity containing additional information regarding this instance.
Status: current Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

agnConfigMsg 1.3.6.1.4.1.164.6.2.6
Full configuration message coded in internal RAD application format. This entry describes agent's configuration. For MP-2200 R3, this object describes agent's support of the V5.1 feature: 1 octet ; bit 0 (LSB). '1' - V5.1 feature is supported '0' - V5.1 feature is not supported.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

mngTrapIpTable 1.3.6.1.4.1.164.6.2.7
This table indicates the destination address of the traps. Internally it will be limited to ten addresses.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MngEntry

mngEntry 1.3.6.1.4.1.164.6.2.7.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  MngEntry  

mngID 1.3.6.1.4.1.164.6.2.7.1.1
This value indicates an index of a specific IP address
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

mngIP 1.3.6.1.4.1.164.6.2.7.1.2
This value indicates the destination address of the traps. IP 0.0.0.0 removes the entry.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

mngIPMask 1.3.6.1.4.1.164.6.2.7.1.3
This value indicates the mask of the destination addresses of the traps.
Status: deprecated Access: read-write
OBJECT-TYPE    
  IpAddress  

mngTrapMask 1.3.6.1.4.1.164.6.2.7.1.4
The value of this attribute determines the type of traps the agent should mask and not send to this NMS. The value is differently determined for different products. There are mainly two methods: - an integer number, specifying the traps' severity. - a sum of 2**n, where n is a bit assigned to a certain masked trap group. User should consult the product specification, to find out the method employed.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

mngAlarmTrapMask 1.3.6.1.4.1.164.6.2.7.1.5
The value of this object determines the alarm traps that the agent should mask (not send to this manager). The value is an Octet String, where each bit is assigned to a certain trap. If the bit = 1, the trap will be masked. If the bit = 0, the trap will not be masked. For more details on the specific alarm traps masked, see product specification.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

mngSnmpTrapUdpPort 1.3.6.1.4.1.164.6.2.7.1.6
This variable enables to set the UDP port (socket) used for SNMP traps.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

agnIndication 1.3.6.1.4.1.164.6.2.8
Attribute describing the state of the entity the agent is responsible for. In case of a modular entity, the value of this attribute will be according to the component which is in the worst state. The order of severity (from top to bottom) is: critical-> major (or faulty)-> minor-> event-> warning-> normal (off).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER faulty(1), warning(2), normal(3), minor(4), major(5), event(6), critical(7)  

agnMonitorModeCmd 1.3.6.1.4.1.164.6.2.9
Setting this attribute to ON, will enforce the agent to change its mode of operation to Monitor Mode
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), off(2), on(3)  

agnLed 1.3.6.1.4.1.164.6.2.10
This entry specifies the LEDs status of the agent module . Each led will be represented by 4 bits where the first 2 bits (left) will specify the status : (00=NA, 01=OFF, 10=ON, 11=BLINK), and the next two bits (right) will specify the color : (00=GREEN, 01=RED, 10=YELLOW, 11=GRAY)
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

trapTable 1.3.6.1.4.1.164.6.2.11
This table may include the last few traps generated by the agent, for future retrieval. The table has a limited capacity. If traps are not retrieved in proper time, they will be over-written by new traps. For other devices, it can include generic variables that will be attached to traps as 'accessible-for-notify'.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TrapEntry

trapEntry 1.3.6.1.4.1.164.6.2.11.1
An entry in trapTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  TrapEntry  

trapID 1.3.6.1.4.1.164.6.2.11.1.1
This object indicates an index of a specific trap. Can be used also for any trap, while trapVal is used as 'accessible-for-notify' or trapNumeric is used.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

trapVal 1.3.6.1.4.1.164.6.2.11.1.2
This object is the actual ASCII description of the trap. It can be used also as attached variable of traps, in order to detail in explicit ASCII text, data of the trap. In this case, it is used as 'accessible-for-notify'.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

trapTimeSinceOccurrence 1.3.6.1.4.1.164.6.2.11.1.3
This object indicates the amount of time passed since the occurrence of the event that triggered this trap.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

trapNumeric 1.3.6.1.4.1.164.6.2.11.1.4
This object is a numeric general parameter, that can be attached to any trap. Values can be positive or negative.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

fileTransfer 1.3.6.1.4.1.164.6.2.12
OBJECT IDENTIFIER    

fileServerIP 1.3.6.1.4.1.164.6.2.12.1
The IP address of the server from which the file is loaded
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

fileName 1.3.6.1.4.1.164.6.2.12.2
The name of the file to be loaded. For protection, read returns NULL.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

fileTransCmd 1.3.6.1.4.1.164.6.2.12.3
The command to be executed on fileName at fileServerIP.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER swDwnLoad(1), configDwnLoad(2), configUpLoad(3), coProcDwnLoad(4), stateUpLoad(5), dwnLoadUserFile(6), upLoadUserFile(7), swDwnLoadAndReset(8), swUpLoad(9), swDwnLoad2BkupStorage(10), bootDwnLoad(11), bootUpLoad(12), swUpLoadFromBkupStorage(13), licenseDwnLoad(14), configDwnLoadToDefaultFile(15), noOp(255)  

tftpRetryTimeOut 1.3.6.1.4.1.164.6.2.12.4
General Retransmission time-out value (seconds)
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

tftpTotalTimeOut 1.3.6.1.4.1.164.6.2.12.5
Total Retransmission time-out value (seconds)
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

tftpStatus 1.3.6.1.4.1.164.6.2.12.6
Status of tftp session. When a session ended with success, the tftpStatus should be endedOk(6). Before restarting a tftp session, the NMS should set the tftpStatus to noOp(2). That's the reason of MAX-ACCESS read-write to this field.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noOp(2), connecting(3), transferringData(4), endedTimeOut(5), endedOk(6), error(7)  

tftpError 1.3.6.1.4.1.164.6.2.12.7
The MSB represents the standard error code. The LSB represents the private error code. 0x0000 is No Error 0x0100 is File Not Found 0x0200 is Access violation 0x0300 is Disk full or allocation exceeded 0x0400 is Illegal TFTP operation 0x0500 is Unknown transfer ID 0x0600 is File already exists 0x0700 is No such user 0x0001 is Server Overflow 0x0002 is No empty UDP port 0x0003 is No empty connection 0x0004 is Illegal File Mode 0x0007 is Illegal PDU size 0x0008 is TFTP Server does not exist 0x0009 is Incorrect File 0x000A is Wrong License format 0x000B is License ID already used
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(2)  

fileTransferToSubSystems 1.3.6.1.4.1.164.6.2.12.8
This object represents the sub-systems the fileTransCmd refers to. It should be used when a system is divided to sub-systems and each sub-system (or part of them) can have a different SW/Configuration. Each bit of this object will represent one of the sub-systems. Bit='1' - APPLY to respective sub-system Bit='0' - DO NOT APPLY to respective sub-system For the meaning of each bit, see product's specification. User will select the sub-systems envolved by filling-in the bits that represent these sub-systems. In this case, the file represented by 'fileName' will include several parts, each representing one of the sub-systems. The agent will refer only to the part/s indicated by this object. 0 Octet Strings = not applicable DEFVAL = 0h for the products that support this object.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

fileNameWithinProduct 1.3.6.1.4.1.164.6.2.12.9
The file name used by the product within the product file system.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

intSwdlTable 1.3.6.1.4.1.164.6.2.12.10
This parameters table is for internal Software down load. It also includes data about all files contained in the Object from which down-load is performed.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IntSwdlEntry

intSwdlEntry 1.3.6.1.4.1.164.6.2.12.10.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  IntSwdlEntry  

intSwdlObjIdx 1.3.6.1.4.1.164.6.2.12.10.1.1
The index of the object from which down-load is performed.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

intSwdlFileIdx 1.3.6.1.4.1.164.6.2.12.10.1.2
The index of the files included in intSwdlObjIdx. One of these files can be selected to be internally downloaded.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

intSwdlFileName 1.3.6.1.4.1.164.6.2.12.10.1.3
The name of the file.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

intSwdlFileSwVer 1.3.6.1.4.1.164.6.2.12.10.1.4
The software version of the file.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

intSwdlSwDate 1.3.6.1.4.1.164.6.2.12.10.1.5
The software version date of the file.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

intSwdlSize 1.3.6.1.4.1.164.6.2.12.10.1.6
The size of the file.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

intSwdlCmd 1.3.6.1.4.1.164.6.2.12.10.1.7
The command to down-load a SW file to an object. The Agent will change the value of this MIB object to off(2) automatically, after accepting the command.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), off(2), on(3)  

intSwdlToSubSystem 1.3.6.1.4.1.164.6.2.12.10.1.8
This object defines the subsystem for download. Bit='1'- APPLY to respective sub system. Bit='0'- DO NOT APPLY to respective sub system. For more details see product specification. For every octet bit0=LSB, bit7=MSB
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

intSwdlCardType 1.3.6.1.4.1.164.6.2.12.10.1.9
This object defines the Card type that this file is relevant for.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), gstm1(220), goc3(221), gstm1D(222), goc3D(223), serverE1(270), serverT1(271), serverE1Pw(272), serverT1Pw(273), gigabitEth(280), gigabitEth2(281), eth2(282), gigabitEth8(283), eth8(284), channelizedT3Pw1(290), cesT128(300), cesE128(301), cesT1Pw28(302), cesE1Pw28(303), vmxE1VeDe(310), vmxE1VeDi(311), vmxE1ViDe(312), vmxE1ViDi(313), vmxT1VeDe(314), vmxT1VeDi(315), vmxT1ViDe(316), vmxT1ViDi(317), vc12E1UeNe(318), vc12E1UeNi(319), vc12E1UiNe(320), vc12E1UiNi(321), vc12T1UeNe(322), vc12T1UeNi(323), vc12T1UiNe(324), vc12T1UiNi(325), vca16E1UeNe(326), vca16E1UeNi(327), vca16E1UiNe(328), vca16E1UiNi(329), vca16T1UeNe(330), vca16T1UeNi(331), vca16T1UiNe(332), vca16T1UiNi(333), vca12E1UeNe(334), vca12E1UeNi(335), vca12E1UiNe(336), vca12E1UiNi(337), vca12T1UeNe(338), vca12T1UeNi(339), vca12T1UiNe(340), vca12T1UiNi(341), vmg16E1Ue(342), vmg16E1Ui(343), vmg16T1Ue(344), vmg16T1Ui(345), vmg12E1Ue(346), vmg12E1Ui(347), vmg12T1Ue(348), vmg12T1Ui(349)  

intSwdlFlashIdx 1.3.6.1.4.1.164.6.2.12.10.1.10
The index of the flash memory this file is stored in (1 or 2) (Example: 1= The file is stored in flash No.1). ASMi52 file will always be stored in Flash No.2 (intSwdlFlashIdx=2).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

swdlStatusTable 1.3.6.1.4.1.164.6.2.12.11
This parameters table is for software download status. It also includes data about the files down-loaded or attempted to be down-loaded.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SwdlStatusEntry

swdlStatusEntry 1.3.6.1.4.1.164.6.2.12.11.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SwdlStatusEntry  

swdlStatusTypeIdx 1.3.6.1.4.1.164.6.2.12.11.1.1
The index of the down-load type (e.g. external (1) or internal (2)).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

swdlStatusIdx 1.3.6.1.4.1.164.6.2.12.11.1.2
The index of the status rows.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

swdlStatusFileName 1.3.6.1.4.1.164.6.2.12.11.1.3
The name of the file.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

swdlStatusSlot 1.3.6.1.4.1.164.6.2.12.11.1.4
The slot of the updated (or attempted to be updated) object.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

swdlStatusSubSystem 1.3.6.1.4.1.164.6.2.12.11.1.5
The subsystem that updated (or attempted to be updated).
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

swdlStatusStatus 1.3.6.1.4.1.164.6.2.12.11.1.6
The status of the down load process. Value: Fail (2), OK (3), InProcess (4).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

swdlStatusTime 1.3.6.1.4.1.164.6.2.12.11.1.7
This MIB parameter indicates the time SW download was finished. The format shuld be YYYY-MM-DD, hh:mm:ss
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

clearDwldStatusLog 1.3.6.1.4.1.164.6.2.12.12
This object clears the status log. Value: off(2), external(3), internal(4) The Agent will change the value of this MIB object to off(2) automatically, after accepting the command .
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

autoFileTransfer 1.3.6.1.4.1.164.6.2.12.13
OBJECT IDENTIFIER    

autoFileTransferTable 1.3.6.1.4.1.164.6.2.12.13.1
Scheduling configuration table for Agent initiated file transfer.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AutoFileTransferEntry

autoFileTransferEntry 1.3.6.1.4.1.164.6.2.12.13.1.1
An entry in the table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AutoFileTransferEntry  

autoFileTransferType 1.3.6.1.4.1.164.6.2.12.13.1.1.1
This object defines the type of file to be transferred by agent.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER alarmsBuffer(1)  

autoFileTransferServerIp 1.3.6.1.4.1.164.6.2.12.13.1.1.2
This object defines the IP Address of the server to which the file is uploaded.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

autoFileTransferFileName 1.3.6.1.4.1.164.6.2.12.13.1.1.3
This object defines the name of the file to be uploaded.
Status: current Access: read-write
OBJECT-TYPE    
  SnmpAdminString  

autoFileTransferScheduling 1.3.6.1.4.1.164.6.2.12.13.1.1.4
This object defines schedule for TFTP Automatic session(s) initiated by Agent, according to the value selected: now - initiate immediate single session. recurrence- initiate single session 'every M time units'. or 'every N occurrences' or upon both, (earliest event). Time reccurence period (M) is defined by fileTransferTimeRecurrence. Occurrence reccurence (N) is defined by fileTransferOccurrenceRecurrence. Zero value means that the object is not relevant (not taken into account for the recurrence). It is invalid that both will have zero values in our case (recurrence). When both are non zero, file is transferred upon earliest event
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), now(2), recurrence(3)  

autoFileTransferTimeRecurrence 1.3.6.1.4.1.164.6.2.12.13.1.1.5
This object defines time reccurence interval, e.g. M can be 'every M days', 'every M hours' etc. Zero is used to indicate there's no time reccurence (0= notApplicable). This object is taken into account only if autoFileTransferScheduling = recurrence For LA-110 time units are days.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

autoFileTransferOccurrenceRecurrence 1.3.6.1.4.1.164.6.2.12.13.1.1.6
This object defines Occurrence reccurence interval, e.g N can be in 'every N alarms', 'every N log entries' etc. zero is used to indicate There's no Event Reccurence. (0= notApplicable) This object is taken into account only if autoFileTransferScheduling = recurrence Occurence Type (Alarms, etc.) is according to autoFileTransferType.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

fileTransferServerPort 1.3.6.1.4.1.164.6.2.12.14
Server Port number used for File Transfer. Applicable for SFTP. Valid values: 0..65535.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

fileTransferProtocol 1.3.6.1.4.1.164.6.2.12.15
File Transfer protocol used.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER tftp(1), sftp(2)  

systemReset 1.3.6.1.4.1.164.6.2.13
Reset action to be performed on the system. - resetMapping - reset SDH/SONET mapping to default for all SDH/SONET links. - resetStandby(6) - can be used only by devices with redundancy on MAIN/CL.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3), resetConfig(4), resetMapping(5), resetStandby(6)  

systemTiming 1.3.6.1.4.1.164.6.2.14
OBJECT IDENTIFIER    

systemDate 1.3.6.1.4.1.164.6.2.14.1
System date.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

systemTime 1.3.6.1.4.1.164.6.2.14.2
System time.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

systemTimeElapsed 1.3.6.1.4.1.164.6.2.14.3
The number of seconds that have elapsed since the beginning of the current error-measurement period. Same for all ports of the device.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..899  

systemNtp 1.3.6.1.4.1.164.6.2.14.4
OBJECT IDENTIFIER    

systemNtpMode 1.3.6.1.4.1.164.6.2.14.4.1
This variable represents the NTP Mode.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(2), broadcastClient(3), unicastClient(4)  

systemNtpGmt 1.3.6.1.4.1.164.6.2.14.4.2
This variable represents the NTP GMT (Greenwich Mean Time), Possible values range is -12..12. For new devices/versions this variable will be in minutes.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

systemNtpServerAddressType 1.3.6.1.4.1.164.6.2.14.4.3
This variable represents the NTP Server Address Type.
Status: current Access: read-write
OBJECT-TYPE    
  InetAddressType  

systemNtpServerAddress 1.3.6.1.4.1.164.6.2.14.4.4
This variable represents the NTP Server Address.
Status: current Access: read-write
OBJECT-TYPE    
  InetAddress  

systemNtpUpdateInterval 1.3.6.1.4.1.164.6.2.14.4.5
This variable represents the NTP Update Interval, measured in seconds.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

systemNtpCmd 1.3.6.1.4.1.164.6.2.14.4.6
This variable represents NTP possible commands. After the Agent accepts a command, it will automatically change the value to off(2).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), sendUpdateRequest(3)  

schedXTable 1.3.6.1.4.1.164.6.2.14.5
An Augment to the Schedule table (schedTable in DISMAN-SCHEDULE-MIB; RFC-3231).
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SchedXEntry

schedXEntry 1.3.6.1.4.1.164.6.2.14.5.1
An entry in the table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SchedXEntry  

schedYear 1.3.6.1.4.1.164.6.2.14.5.1.1
The year during which the scheduled action should take place.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

schedWeekInMonth 1.3.6.1.4.1.164.6.2.14.5.1.2
The week in month (schedMonth) during which the scheduled action should take place.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER first(1), second(2), third(3), fourth(4), last(5)  

schedParam 1.3.6.1.4.1.164.6.2.14.5.1.3
A Parameter that might be used whenever the scheduled action takes place. For summer-time schedule - This variable represents the time offset (in minutes), meaning: the number of minutes that should be added for summer-time.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

systemPort 1.3.6.1.4.1.164.6.2.15
OBJECT IDENTIFIER    

physicalConnectorTable 1.3.6.1.4.1.164.6.2.15.1
This table includes the connector type of ports or interfaces.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PhysicalConnectorEntry

physicalConnectorEntry 1.3.6.1.4.1.164.6.2.15.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PhysicalConnectorEntry  

portIdx 1.3.6.1.4.1.164.6.2.15.1.1.1
This object is an index of the specific port or interface. For a port, the index will be as agreed between agent and application. For an interface, ifIndex may be used.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

physicalConnector 1.3.6.1.4.1.164.6.2.15.1.1.2
The connector of the port/interface. other - none of the specified connectors none - no connector.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER other(1), v35(2), rs530(3), x21(4), bnc(5), utp(6), aui(7), rs422(8), crossUtp(9), rj45(10), v24(11), g703(12), termBlock3AndRj45(13), terminalBlock3(14), terminalBlock5(15), terminalBlock7(16), db25(17), db15(18), rj45ethernet(19), termBlock5AndRj45(20), db9(21), g703E1(22), g703E1-LTU(23), sc(24), st(25), stl(26), fc(27), tb5w(28), termBlock6AndRj45(29), ethBnc(30), scsi26(31), eth4381(32), twoBnc(33), scsi50(34), twoMiniBnc(35), sf1(36), terminalBlock4(37), sf2(38), db25Balanced(39), v36(40), block4W(41), iripRj45(42), irEthQRj45(43), iripBnc(44), rs530WA(45), v35WA(46), irEthQBnc(47), v35Db25(48), rj11(49), mtrj(50), lc(51), terminalBlock2(52), irEth10s100(53), scsi68(54), sf3(55), fcLH(56), telco50(57), telco64(58), irEthQN(59), terminalBlock6(60), scLH(61), stLH(62), lcLH(63), sfpIn(64), sfpOut(65), db44(66), db62(67), v24Db9(68), scsi40(69), sf1NineRow(70), sf2NineRow(71), sf3NineRow(72), smartSerial26(73), miniUsb5(74), db26(75), none(255)  

portOptWaveLength 1.3.6.1.4.1.164.6.2.15.1.1.3
Wave Length of an Optical interface/port in [nm] and specification if Laser or not. notApplicable - for non-optical ports.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), nm850(2), nm1310(3), nm1310Laser(4), nm1550Laser(5), nm1470Laser(6), nm1490Laser(7), nm1510Laser(8), nm1530Laser(9), nm1570Laser(10), nm1590Laser(11), nm1610Laser(12)  

portOptMode 1.3.6.1.4.1.164.6.2.15.1.1.4
Laser Mode of an Optical Laser interface/port. notApplicable - for non-Laser ports.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), singleMode(2), multiMode(3)  

portBalance 1.3.6.1.4.1.164.6.2.15.1.1.5
This object is according to the port Impedance. For T1 - always balanced. For E1 - there are different impedance values for balanced and unbalanced.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), unbalanced(2), balanced(3)  

portDdmSupport 1.3.6.1.4.1.164.6.2.15.1.1.6
SFP (Small Form Pluggable) port -support Digital Diagnostics Monitoring.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

portMfgName 1.3.6.1.4.1.164.6.2.15.1.1.7
(SFP) Port Manufacturer name (Maximum - 16 characters).
Status: current Access: read-only
OBJECT-TYPE    
  SnmpAdminString  

portTypicalMaxRange 1.3.6.1.4.1.164.6.2.15.1.1.8
Maximum range supported by SFP port, in meter units.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

physicalConnectorString 1.3.6.1.4.1.164.6.2.15.1.1.9
(SFP) connector type. It can be Vendor Specific (unknown in advance). Being a string, the object is not affected by any future new connectors. This object will usually not be used for drawing the connector.
Status: current Access: read-only
OBJECT-TYPE    
  SnmpAdminString  

portVendorPartNo 1.3.6.1.4.1.164.6.2.15.1.1.10
SFP Vendor Part Number. Being a string, the object is not affected by any future new SFPs.
Status: current Access: read-only
OBJECT-TYPE    
  SnmpAdminString  

prtSupervisory 1.3.6.1.4.1.164.6.2.15.2
OBJECT IDENTIFIER    

prtSpTable 1.3.6.1.4.1.164.6.2.15.2.1
A table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtSpEntry

prtSpEntry 1.3.6.1.4.1.164.6.2.15.2.1.1
Supervisory port parameter table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtSpEntry  

prtSupervisoryIndex 1.3.6.1.4.1.164.6.2.15.2.1.1.1
The SP port index. For some products, having modules (cards): The LS byte of the integer is the port index 1..255. The MS byte is different than 0 only if the port belongs to a module. In that case it is the module number. For other products' index see their specification.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtSupervisoryRate 1.3.6.1.4.1.164.6.2.15.2.1.1.2
This attribute indicates the operation rate (speed) of the port. auto - automatic rate selection, by the agent.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER auto(1), s300bps(2), s1200bps(3), s2400bps(4), s4800bps(5), s9600bps(6), s19200bps(7), s38400bps(8), s57600bps(9), s115200bps(10)  

prtSupervisoryDataBits 1.3.6.1.4.1.164.6.2.15.2.1.1.3
This attribute indicates the number of data bits in an async frame
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER dataBits7(1), dataBits8(2)  

prtSupervisoryParity 1.3.6.1.4.1.164.6.2.15.2.1.1.4
This attribute indicates the parity mode in an async frame
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), odd(2), even(3)  

prtSupervisoryStopBits 1.3.6.1.4.1.164.6.2.15.2.1.1.5
This attribute indicates the parity mode in an async frame.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), stopBits1(2), stopBits1dot5(3), stopBits2(4)  

prtSupervisoryUsage 1.3.6.1.4.1.164.6.2.15.2.1.1.6
This attribute indicates the usage of the SP port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), noUse(2), terminal(3), nmsSlip(4), nmsPpp(5), muxSlip(6), muxPpp(7), dialOut(8)  

prtSupervisoryInterface 1.3.6.1.4.1.164.6.2.15.2.1.1.7
This attribute indicates the supervisory port interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), dce(2), dte(3)  

prtSupervisoryCTS 1.3.6.1.4.1.164.6.2.15.2.1.1.8
CTS line state.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), on(2), rts(3), dteWait(4), dteIgnore(5)  

prtSupervisoryDcdDelay 1.3.6.1.4.1.164.6.2.15.2.1.1.9
DCD delay in msec.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), d0(2), d10(3), d50(4), d100(5), d200(6), d300(7)  

prtSupervisoryDSR 1.3.6.1.4.1.164.6.2.15.2.1.1.10
DSR line state.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), on(2), dtr(3)  

prtSupervisoryRoutProtocol 1.3.6.1.4.1.164.6.2.15.2.1.1.11
This attribute indicates the routing protocol of the port. notApplicable - for DP.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), none(2), proprietary(3), rip2(4)  

prtPerformance 1.3.6.1.4.1.164.6.2.15.3
OBJECT IDENTIFIER    

prtPerfTable 1.3.6.1.4.1.164.6.2.15.3.1
This table includes G.826 ports or interfaces.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtPerfEntry

prtPerfEntry 1.3.6.1.4.1.164.6.2.15.3.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtPerfEntry  

prtPerfIdx 1.3.6.1.4.1.164.6.2.15.3.1.1.1
This object is an index of the specific port or interface. For a port, the index will be as agreed between agent and application. For an interface, ifIndex may be used.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtPerfPeriodRef 1.3.6.1.4.1.164.6.2.15.3.1.1.2
This object is an index that specifies which period of time, the next 5 objects refer to. currentPeriod - the period since last prtPerfSaveAndResetCmd received or since Start-up (if no prtPerfSaveAndResetCmd was received since Start-up) until now. lastPeriod - the period between last two commands of prtPerfSaveAndResetCmd. - If only one command occured since Start-up: the period between Start-up and last command. - If no command occured since Start-up: this period will not actually exist. In this case, he following 5 objects will be 0.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER currentPeriod(1), lastPeriod(2)  

prtPerfElapsedTime 1.3.6.1.4.1.164.6.2.15.3.1.1.3
Elapsed Time in seconds. - for prtPerfPeriodRef=currentPeriod: The period since last prtPerfSaveAndResetCmd received or since Start-up (if no prtPerfSaveAndResetCmd was received since Start-up) until now. - for prtPerfPeriodRef=lastPeriod: The value of prtPerfElapsedTime when last prtPerfSaveAndResetCmd was received.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtPerfUAS 1.3.6.1.4.1.164.6.2.15.3.1.1.4
Number of Unavailable Seconds for the reference period (prtPerfPeriodRef).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtPerfES 1.3.6.1.4.1.164.6.2.15.3.1.1.5
Number of Errored Seconds for the reference period (prtPerfPeriodRef).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtPerfSES 1.3.6.1.4.1.164.6.2.15.3.1.1.6
Number of Severely Errored Seconds for the reference period (prtPerfPeriodRef).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtPerfBBE 1.3.6.1.4.1.164.6.2.15.3.1.1.7
Number of Background Block (or Frame) Errors for the reference period (prtPerfPeriodRef).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtPerfBlocksPerSec 1.3.6.1.4.1.164.6.2.15.3.1.1.8
Blocks per second (or frames per second) of the port/interface indicated by portIdx. This object is constant for a certain port/interface. It is not affected by the prtPerfPeriodRef index.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtPerfTimeTag 1.3.6.1.4.1.164.6.2.15.3.1.1.9
Time Tag of Last Period: sysUpTime when last prtPerfSaveAndResetCmd was executed. This object is applicable only for prtPerfPeriodRef=lastPeriod. For prtPerfPeriodRef=currentPeriod, the value will always be 0.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

prtPerfSaveAndResetCmd 1.3.6.1.4.1.164.6.2.15.3.1.1.10
A command per port/interface, to Save data of Current Period in Last Period data-set and start a new counting period for Current Period. This object is applicable only for prtPerfPeriodRef=currentPeriod. Setting this object to on(3) for prtPerfPeriodRef=last, will cause the agent to return: Bad Value response. When setting validly this object to on(3), agent will perform the required command and will reset automatically the value of this object to off(2). Setting this object to off(2), will do nothing.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtTest 1.3.6.1.4.1.164.6.2.15.4
OBJECT IDENTIFIER    

prtTestTable 1.3.6.1.4.1.164.6.2.15.4.1
This table includes test data for ports or interfaces.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtTestEntry

prtTestEntry 1.3.6.1.4.1.164.6.2.15.4.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtTestEntry  

prtTestIdx 1.3.6.1.4.1.164.6.2.15.4.1.1.1
This object is an index of the specific port or interface. For a port, the index will be as agreed between agent and application. For an interface, ifIndex may be used.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtTestCmdAndStatus 1.3.6.1.4.1.164.6.2.15.4.1.1.2
Setting this object to a value as detailed further on (except 0) will initiate a test on the specific port. The test/s requested will be set according to the respective bit. The value of this object will be a sum of (2**n), where n is the Bit: TEST BIT VALUE ----------- --- ------ reserved 0 1 PayloadLoop=RLB 1 (=Remote Loopback) 2 LineLoop=DIG 2 (=Digital) 4 OtherLoop 3 8 InwardLoop=LLB 4 (=Local Loopback) 16 BERT 5 32 LC 6 64 ToneInjection 7 128 Inband 8 256 BERT Remote (or E1/T1 RLB) 9 512 Downstream-AIS (or E1/T1 LLB) 10 1024 Upstream-AIS 11 2048 Rem-Loop-on-Rem-Unit 12 4096 MacSwapLoop 13 8192 OamETHLoopback 14 16384 OamETHLinkTrace 15 32768 e.g : If the requested value is 20 -> 010100 -> Bits 2 & 4 are set -> the requested tests are : LineLoopback=DIG InwardLoopback=LLB Not all tests combinations are valid. For valid test combination, see each product's specification. For LRS52, only single test is allowed simultaneously The terminology and order of the first tests (except BERT) is according to the one used for Test Status of DS1 and DS3 standards. The notations : RLB, LLB, DIG are the most used in RAD's products, but they can be different. For exact definition see product's spec. Setting this object to stop (value=0 ; all bits are 0), will stop all the user requested tests running on the selected port. When no test is running on the port, the Get value (test status) will be 0. PayloadLoop=RLB The received signal at this interface is looped through the device. Typically the received signal is looped back for retransmission after it has passed through the device's framing function. LineLoop=DIG The received signal at this interface does not go through the device (minimum penetration) but is looped back out. OtherLoop Loopbacks that are not defined here. InwardLoop=LLB The sent signal at this interface is looped back through the device. LC This loop is applicable only for HSSI interface, towards the router . ToneInjection This loop is applicable for analog voice (like FXS). Downstream-AIS E1 AIS signal (all ones) is transmitted in the relevant channel toward the STM-1 line. Upstream-AIS E1 AIS signal (all ones) is generated in the relevant channel toward the local received tributary channel output Rem-Loop-on-Rem-Unit Request from far end device to activate remote loopback towards near-end device MacSwapLoop This loop is applicable for ethernet port. Loop is implemented by swapping the MAC addresses of the incoming message. OamETHLoopback Ethernet Loopback is used to verify connectivity of a MEP with a MIP or peer MEP(s) (ITU-T Y.1731, Clause 7.2). OamETHLinkTrace Ethernet Link Trace is an on-demand OAM function which can be used for the two following purposes: - Adjacent Relation Retrieval - Fault Localization (ITU-T Y.1731, Clause 7.3).
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtBertCounter 1.3.6.1.4.1.164.6.2.15.4.1.1.3
This object indicates the number of BERT errors encountered during the BERT operation. It is valid only when BERT (Bit Error Rate Test) is active on the specific port. The Counter starts from zero (0) anytime BERT is initiated.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtTestInitiator 1.3.6.1.4.1.164.6.2.15.4.1.1.4
This object indicates who initiated this port's test/s.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), user(2), remoteUnit(3), dteRouter(4)  

prtTestTimeout 1.3.6.1.4.1.164.6.2.15.4.1.1.5
This object is applicable only when a single test is running. It indicates the test activation timeout in minutes. For RICi-E1T1, RICi-E3T3 the measurement unit is in seconds. When the timeout expires, the test is stopped. Value of 0 indicates test may run Forever
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..4095  

prtTestVctRxResult 1.3.6.1.4.1.164.6.2.15.4.1.1.6
This object indicates the result of the Vct on the cable connected to the RX connector.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), fail(2), normal(3), open(4), short(5), shortToCrossPair(6), coupleWithCrossPair(7)  

prtTestVctTxResult 1.3.6.1.4.1.164.6.2.15.4.1.1.7
This object indicates the result of the Vct on the cable connected to the TX connector.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), fail(2), normal(3), open(4), short(5), shortToCrossPair(6), coupleWithCrossPair(7)  

prtTestVctRxDistance 1.3.6.1.4.1.164.6.2.15.4.1.1.8
This object indicates the distance in Meters to the RX cable Open/ Short location discovered by the Vct. This parameter is applicable for Vct Result = Normal or Fail only, Else the value of this parameter will be equal to 0.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtTestVctTxDistance 1.3.6.1.4.1.164.6.2.15.4.1.1.9
This object indicates the distance in Meters to the TX cable Open/ Short location discovered by the Vct. This parameter is applicable for Vct Result = Normal or Fail only, Else the value of this parameter will be equal to 0.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtTestVctCmd 1.3.6.1.4.1.164.6.2.15.4.1.1.10
Vct command. on (3) = Start Vct on both cables connected to RX and TX connectors of this port. Agent will perform the required command and change automatically the value of this object to off(2).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtTestVctRxCrossPair 1.3.6.1.4.1.164.6.2.15.4.1.1.11
This object should be equal to the Index (prtTestIdx) of the Rx cross pair. This object is applicable only for Vct Result = shortToCrossPair or coupleWithCrossPair. This object was especially created for ETX-202. Currently not in use.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtTestVctTxCrossPair 1.3.6.1.4.1.164.6.2.15.4.1.1.12
This object should be equal to the Index (prtTestIdx) of the Tx cross pair. This object is applicable only for Vct Result = shortToCrossPair or coupleWithCrossPair.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtTestActivationDelay 1.3.6.1.4.1.164.6.2.15.4.1.1.13
This object is applicable only when a single test is running. It indicates test activation delay in seconds. A Value of 0 indicates that the test starts immediately.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

prtTestMacSwapLoopDataMode 1.3.6.1.4.1.164.6.2.15.4.1.1.14
This object defines which part of the data will be looped back.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER all(1), allExceptMng(2), specificVlan(3)  

prtTestMacSwapLoopVlanId 1.3.6.1.4.1.164.6.2.15.4.1.1.15
This object specifies the VLAN ID for prtTestMacSwapLoopDataMode=specificVlan.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtTestMacSwapLoopDirection 1.3.6.1.4.1.164.6.2.15.4.1.1.16
This object defines the direction of the performed loopback. In ETX102 'local' corresponds to Ingress loop (either on User port or on Network port), and 'remote' corresponds to Egress loop (either on User port or on Network port).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER local(2), remote(3)  

prtTestMacSwapLoopDestAddr 1.3.6.1.4.1.164.6.2.15.4.1.1.17
Configures the MAC address that will be sent in the Destination field of the packet in the outgoing direction.
Status: current Access: read-write
OBJECT-TYPE    
  MacAddress  

prtTestMacSwapLoopSrcAddr 1.3.6.1.4.1.164.6.2.15.4.1.1.18
Configures the MAC address that will be sent in the Source field of the packet in the outgoing direction.
Status: current Access: read-write
OBJECT-TYPE    
  MacAddress  

prtTestOamMinRoundTripDelay 1.3.6.1.4.1.164.6.2.15.4.1.1.19
The mininal value of round trip delay of loopback message for a session of OAM loopback.Units are msec.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

prtTestOamMaxRoundTripDelay 1.3.6.1.4.1.164.6.2.15.4.1.1.20
The maximum value of round trip delay of loopback message for a session of OAM loopback.Units are msec.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

prtTestOamAvgRoundTripDelay 1.3.6.1.4.1.164.6.2.15.4.1.1.21
The average round trip delay of loopback message for a session of OAM loopback.Units are msec.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

prtTestOamTxInterval 1.3.6.1.4.1.164.6.2.15.4.1.1.22
Indicates the interval between loopback sent messages.Units are msec.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

prtTestDestinationIpAddress 1.3.6.1.4.1.164.6.2.15.4.1.1.23
Indicates the destination IP Address in the transmitted messages that are looped back.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

prtTestTTL 1.3.6.1.4.1.164.6.2.15.4.1.1.24
Time-to-live.Number of hops the loopback message will go through the net before deciding to discard it.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

prtTestBwProfile 1.3.6.1.4.1.164.6.2.15.4.1.1.25
Indicates the BW profile (from bwProfileTable) that is assigned to the loopback test in order to limit the traffic that is looped back.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

prtParam 1.3.6.1.4.1.164.6.2.15.5
OBJECT IDENTIFIER    

prtParamTable 1.3.6.1.4.1.164.6.2.15.5.1
This table includes general port parameters. The meaning is different for every product that supports it due to a general parameter - prtControlCnfg. For ACE2002: -This table is used as a mechanism to create the next interface index. The algorithm description: The NMS will send the agent the following get command: get(nextIfIndex.index), where index=interface on which the new index is dependent on. Upon this command the agent will generate and return the new index to the NMS. - This table is partially supported according to the interface type. Upon getNext function the irrelevant parameters will be skipped.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtParamEntry

prtParamEntry 1.3.6.1.4.1.164.6.2.15.5.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtParamEntry  

prtParamIdx 1.3.6.1.4.1.164.6.2.15.5.1.1.1
This object is an index of the specific port or interface. For a port, the index will be as agreed between agent and application. For an interface, ifIndex may be used. For ACE2002: This parameter is the physical layer ifIndex of the slot on which the NMS requires the next interface index.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtControlCnfg 1.3.6.1.4.1.164.6.2.15.5.1.1.2
This object may be used for port RW general parameter/s. For detailed meaning, see product's spec. Supported by: PRBi-E3/T3. For ACE2002: This parameter will include the value of the new index generated by agent. For Optimux-T3 and OP-155-1: This parameter will be used for Release Remote LLB Command: on=2= Set value only. Command to release LLB of Remote Unit. Agent will return automatically to 'off' value after performing the command. off=3=Get value only. For LA140 This parameter will be used as EchoCanceler per timeslot off = 2 Echo Canceler is disabled on = 3 Echo Canceler is enabled For FCD-155 This parameter will be used to select the port that is clock source for a PDH port, For E1/T1 PDH VC12/VT1.5 = 2 SDH/SONET = 3 For E3/T3 PDH VC3/DS3 = 2 SDH/SONET = 3 For ACE-52 This parameter will be used as Transmit Frame Type, i.e. which type of frame the corresponding bridge port will transmit: Untagged = 2 Tagged = 3 .
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtParamClkSrc 1.3.6.1.4.1.164.6.2.15.5.1.1.3
The source of Transmit Clock. 'loopTiming' or 'loopback' indicates that the recovered receive clock is used as the transmit clock. 'localTiming' or 'internal' indicates that a local clock source is used or when an external clock is attached to the box containing the interface. 'throughTiming' or 'external' indicates that recovered receive clock from another card or interface is used as the transmit clock. 'adaptive' indicates that the clock is recovered according to the received data flow rate. 'master' and 'fallback' values may be used RO to indicate active clock. 'station' - indicate clock received from station port is used as transmit clock.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER loopTiming(1), localTiming(2), throughTiming(3), adaptive(4), master(5), fallback(6), station(7), notApplicable(255)  

prtParamPhantom 1.3.6.1.4.1.164.6.2.15.5.1.1.4
Power feeding to another device.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

prtParamResetStatsCmd 1.3.6.1.4.1.164.6.2.15.5.1.1.5
Reset statistics of the selected port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtParamLastResetStatsTime 1.3.6.1.4.1.164.6.2.15.5.1.1.6
The value of MIB II's sysUpTime object at the last time that prtParamResetStatsCmd was Set to on(3) for this port. If prtParamResetStatsCmd was never Set to on(3) since last re-initialization of the agent, then this object contains a zero value. This object enables calculating the running time of Statistics counters for this port, by: [sysUpTime-prtParamLastResetStatsTime]. For some devices other types of 'Reset' may affect this parameter
Status: current Access: read-only
OBJECT-TYPE    
  TimeStamp  

prtParamInterfaceType 1.3.6.1.4.1.164.6.2.15.5.1.1.7
The type of the port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), e1(2), t1(3), fr(4), hdlc(5), hdsl2(6), shdsl(7), adsl(8), adsl2(9), reAdsl2(10), mPair(11), efm(12), atmIma(13), ds1(14)  

prtParamClearAlarm 1.3.6.1.4.1.164.6.2.15.5.1.1.8
Setting this attribute to ON, will enforce a clear operation on the Port Alarms. Upon completion, the value will automatically change to off(2).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtParamLeds 1.3.6.1.4.1.164.6.2.15.5.1.1.9
This entry specifies the LEDs status of the port. Each led is represented by 4 bits where the first 2 bits (left) specify the status : (00=NA, 01=OFF, 10=ON, 11=BLINK), and the next two bits (right) specify the color : (00=GREEN, 01=RED, 10=YELLOW, 11=GRAY). The order of the LEDS is from top to bottom, left to right: For each row starting from the top, the LEDS are returned from left to right.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

prtParamLineLength 1.3.6.1.4.1.164.6.2.15.5.1.1.10
Line Length of the line connected to this port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), long(2), normal(3), short(4)  

prtParamUsage 1.3.6.1.4.1.164.6.2.15.5.1.1.11
Defines whether this port works as User port or as Network port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), user(2), network(3)  

prtParamMappingMode 1.3.6.1.4.1.164.6.2.15.5.1.1.12
This object defines path protection on SONET/SDH link Auto - SONET/SDH mapping for port is copied automatically to same TU on the redundant SONET/SDH local (reside on same slot) link by agent. Manual - the user can configure the redundant mapping for port on the same link or to the other link on any TU Adjacent - similar to auto, but mapping is copied automatically by agent to link on adjacent slot .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), off(2), auto(3), manual(4), adjacent(5)  

prtParamAlarmIndication 1.3.6.1.4.1.164.6.2.15.5.1.1.13
This object indicates status-aggregation of non-masked alarms associated with all interface layers, related to this physical port. When at least one non-masked alarm exists on any layer, value of this object is on (3). Indication will be off (2) only when there's no active non-masked alarm on any interface layer related to this port. Masking an Alarm, will consider it as not exist for this indication. Example: When a port has an ATM higher layer and at least one VC has alarm, value of this object will be on (3)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), off(2), on(3)  

prtParamClkQualityLevel 1.3.6.1.4.1.164.6.2.15.5.1.1.14
This parameter indicates quality level of clock signal. Quality is encoded according to SSM (Synchronization Status Messages) encoding. Bits 8 -5 of byte are encoded as follows (when bit1=0): Left most bit - MSB(8) ---> LSB(5) 8765 0000 Quality Unknown 0010 PRC (Primary Reference Clock) - Rec. G.811 0100 SSU-T (Sync. Source Unit-Transit)- Rec. G.812 Transit 1000 SSU-L (Sync. Source Unit Local) - Rec. G.812 Local 1011 SEC (SDH Equipment Clock) 1111 DNU (do not use for synchronization) 0001 PRS (=ST1 = Stratum 1 Traceable) 0111 ST2 (Stratum 2 Traceable) 1010 ST3 (Stratum 3 Traceable) 1100 SMC (SONET Minimum Clock Traceable) 1101 Stratum 3E Traceable bit1 = '1' - indicates all octet is Not Applicable
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1)  

prtParamClkWaveShape 1.3.6.1.4.1.164.6.2.15.5.1.1.15
Wave shape of station clock source signal.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), sine(2), square(3)  

prtParamStatus 1.3.6.1.4.1.164.6.2.15.5.1.1.16
Station clock source Status.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), up(2), signalLoss(3), syncLoss(4)  

prtParamSignalLevel 1.3.6.1.4.1.164.6.2.15.5.1.1.17
This object indicates signal level (in thenth of dB units) on selected port.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtParamClkUserQualityLevel 1.3.6.1.4.1.164.6.2.15.5.1.1.18
This parameter allows user to mark quality level of clock. Quality is encoded according to SSM (Synchronization Status Messages) encoding. Bits 8 -5 of byte are encoded as follows: Left most bit - MSB(8) ---> LSB(5) 8765 0000 Quality Unknown 0010 PRC (Primary Reference Clock) - Rec. G.811 0100 SSU-T (Sync. Source Unit-Transit) Rec. G.812 Transit 1000 SSU-L (Sync. Source Unit Local) - Rec. G.812 Local 1011 SEC (SDH Equipment Clock) 1111 DNU (do not use for synchronization)
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1)  

prtParamDataRate 1.3.6.1.4.1.164.6.2.15.5.1.1.19
Rate of serial data port (V.11, V.24, V.35) in kbps units.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

prtParamLoopDetect 1.3.6.1.4.1.164.6.2.15.5.1.1.20
Enable/disable Loop Detection on a port. Examples of ports: physical, Channelized Bundle over TDM Uplink, Bridge Ports.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(2), enable(3)  

prtParamActUponLoopDetect 1.3.6.1.4.1.164.6.2.15.5.1.1.21
This parameter is used to indicate which actions should be taken in case a loop is detected in the network the port is part of. Each action is represented by a bit. Currently defined (for RIC155GE/RIC622GE): Bit 0 - Transmit Shut Down Bit 1 - Forward Alarms If bit value = '1' then the action is taken. If bit value = '0' then the actions is not taken.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

prtParamPSNLayer 1.3.6.1.4.1.164.6.2.15.5.1.1.22
This object indicates the network layer from which clock is derived.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER l2(2), l3(3)  

prtParamRxSsm 1.3.6.1.4.1.164.6.2.15.5.1.1.23
This object indicates if Station Clock SSM messages received will serve as criteria for clock selection.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(2), rx(3)  

prtParamClkSsmRxSource 1.3.6.1.4.1.164.6.2.15.5.1.1.24
This object indicates the Sa-bit of the E1 frame, in which SSM messages are carried.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER sa4(2), sa5(3), sa6(4), sa7(5), sa8(6)  

prtParamFarEndDevice 1.3.6.1.4.1.164.6.2.15.5.1.1.26
Programmed Far-End device connected to this port. This object is relevant for products having multiple DBs. It will enable configuring offline, the relevant data. For MP-4100, LRS-102 OP-108/106 cards, the options will be: 1 = None (when a port is not connected to any remote device) 2 = OP-108 3 = OP-108/ETH 4 = OP-106 5 = OP-106/ETH 6 = card of MP or LRS-102
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

prtParamTxClk 1.3.6.1.4.1.164.6.2.15.5.1.1.27
enable/disable station clock signal output.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

prtIP 1.3.6.1.4.1.164.6.2.15.6
OBJECT IDENTIFIER    

prtIpParamTable 1.3.6.1.4.1.164.6.2.15.6.1
A table - Parameters for IP Ports.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtIpParamEntry

prtIpParamEntry 1.3.6.1.4.1.164.6.2.15.6.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtIpParamEntry  

prtIpParamConfigIdx 1.3.6.1.4.1.164.6.2.15.6.1.1.1
This object indicates the Configuration number (1..255) referred. Value of 255 specifies the TmpCnfg (Scratch). For products having Agent and Edit configurations, Write operation for the table entries is allowed only to Config=255.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtIpParamSlotIdx 1.3.6.1.4.1.164.6.2.15.6.1.1.2
This object indicates a unique number of the slot position in which the module is inserted. notApplicable = 255 (for products that don't have slots). For KM: kmxMlA (103), kmxMlB (104).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtIpParamIdx 1.3.6.1.4.1.164.6.2.15.6.1.1.3
This object indicates a unique Port Index.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtIpParamHostIP 1.3.6.1.4.1.164.6.2.15.6.1.1.4
The host interface IP address.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

prtIpParamHostMask 1.3.6.1.4.1.164.6.2.15.6.1.1.5
The host interface subnet mask.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

prtIpParamDefaultGateway 1.3.6.1.4.1.164.6.2.15.6.1.1.6
Default Gateway's IP Address.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

prtIpParamMediaMode 1.3.6.1.4.1.164.6.2.15.6.1.1.7
This object indicates the real Media Mode.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), halfDuplex(2), fullDuplex(3)  

prtIpParamMediaRate 1.3.6.1.4.1.164.6.2.15.6.1.1.8
This object indicates the real Media Rate (Mbps).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), r10Mbps(2), r100Mbps(3)  

prtIpParamMngVlanSupport 1.3.6.1.4.1.164.6.2.15.6.1.1.9
Management VLAN support (Tagging). no - No support of VLAN Tagging. yes - 4 VLAN bytes will be added to the frame.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

prtIpParamMngVlanId 1.3.6.1.4.1.164.6.2.15.6.1.1.10
Management VLAN ID.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtIpParamMngVlanPriority 1.3.6.1.4.1.164.6.2.15.6.1.1.11
Management VLAN Frame priority.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtIpParamRingMode 1.3.6.1.4.1.164.6.2.15.6.1.1.12
This object indicates If Ring Mode is enabled or not.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

prtIpParamProtIpEnable 1.3.6.1.4.1.164.6.2.15.6.1.1.13
This object indicates whether a list of Protected IP Addresses is enabled or not. This object is applicable only if prtIpParamRingMode=enable.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

prtIpParamTrafficPriority 1.3.6.1.4.1.164.6.2.15.6.1.1.14
This object indicates the traffic priority of this port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), low(2), high(3)  

prtIpParamRemoteIP 1.3.6.1.4.1.164.6.2.15.6.1.1.15
This is the IP Address of the remote device that is connected to the current device (Point to Point Application). It is used for sending OAM packets on the LAN to the remote side in order to check that the connection is OK.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

prtIpParamMaxTxBandwidth 1.3.6.1.4.1.164.6.2.15.6.1.1.16
This object shows the Max Bandwidth allowed on the LAN. Full - means that a Maximum of 100 Mega Byte Rate may go through the LAN. e1(3) means that the maximum is an E1 rate. t1(4) is for a maximum of a T1 rate.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER full(2), e1(3), t1(4)  

prtIpParamTos 1.3.6.1.4.1.164.6.2.15.6.1.1.17
TOS = Type of Service transmitted. Valid values: 0..255.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtIpParamConnect 1.3.6.1.4.1.164.6.2.15.6.1.1.18
Port Connection.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

prtIpParamAgingTime 1.3.6.1.4.1.164.6.2.15.6.1.1.19
Aging Time in seconds.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtIpParamEncapsulationProt 1.3.6.1.4.1.164.6.2.15.6.1.1.20
Encapsulation Protocol.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), tcp(2), udp(3)  

prtIpParamEncapProtPort 1.3.6.1.4.1.164.6.2.15.6.1.1.21
Encapsulation Protocol Port (TCP/UDP Port).
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtIpParamVlanSupport 1.3.6.1.4.1.164.6.2.15.6.1.1.22
VLAN support (Tagging). 'no' - No support of VLAN Tagging. 'yes' - 4 VLAN bytes will be added to the frame.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

prtIpParamVlanId 1.3.6.1.4.1.164.6.2.15.6.1.1.23
VLAN Identifier.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtIpParamVlanPriority 1.3.6.1.4.1.164.6.2.15.6.1.1.24
VLAN Frame priority.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtIpParamDoubleTagVlanId 1.3.6.1.4.1.164.6.2.15.6.1.1.25
VLAN Identifier of the Double Tagging VLAN.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtIpParamDoubleTagVlanPriority 1.3.6.1.4.1.164.6.2.15.6.1.1.26
VLAN Frame priority of the Double Tagging VLAN.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtIpParamVlanTagging 1.3.6.1.4.1.164.6.2.15.6.1.1.27
VLAN Tagging. 'unmodified' - No change will be done to the Frame. 'tag' - Add Tag to Untagged Frames. 'doubleTag' - Add Tag to all Frames. 'doubleTagAndFallBack' - Double Tagging will have different rules for VLANs that this port is member in, than these it is not a member in. 'untag' - Remove Tag from tagged frames.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), unmodified(2), tag(3), doubleTag(4), doubleTagAndFallBack(5), untag(6)  

prtIpParamRateLimit 1.3.6.1.4.1.164.6.2.15.6.1.1.28
The maximum rate permitted to transfer via this port, in Kbps.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtIpParamDefInterface 1.3.6.1.4.1.164.6.2.15.6.1.1.29
The Default Interface for packets with unresolved destination subnet. For internal-X port: 100 + X .
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtIpParamMng 1.3.6.1.4.1.164.6.2.15.6.1.1.30
This object indicates whether Management is enabled/disabled via this port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

prtIpParamFloodedRateLimit 1.3.6.1.4.1.164.6.2.15.6.1.1.31
The maximum rate permitted to transfer broadcast, multicast, and unicast flooded frames via this port, in Kbps. 0 - Disable. In Ipmux14 this parameter is applicable when prtIpParamRateLimit=0 (disable).
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtIpParamBurstSize 1.3.6.1.4.1.164.6.2.15.6.1.1.32
The burst size that the port can support beyond rate limitation determined in prtIpParamRateLimit. Burst Size is measured in bytes.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

prtIpParamLimitPacketType 1.3.6.1.4.1.164.6.2.15.6.1.1.33
The packet type that will be rate limited. Rate limitation determined in prtIpParamRateLimit. all - All packet types are rate limited. broadMultiFloodedUnicast - Broadcast, Multicast and Flooded Unicast packets are rate limited. broadcastMulticast - Broadcast and Multicast packets are rate limited. broadcast - Broadcast packets are rate limited.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER all(1), broadMultiFloodedUnicast(2), broadcastMulticast(3), broadcast(4)  

prtIpParamKeepAliveInterval 1.3.6.1.4.1.164.6.2.15.6.1.1.34
This parameter indicates the period of time (in msec.) between two consequent Keep Alive messages.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtIpParamKeepAliveThresh 1.3.6.1.4.1.164.6.2.15.6.1.1.35
This parameter indicates the maximum number of missed Keep Alive answer messages acceptable, after which link status will be failed.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtIpParamP2pKeepAliveVlanId 1.3.6.1.4.1.164.6.2.15.6.1.1.36
Dedicated VLAN ID for keep alive messages.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtIpParamP2pKeepAliveVlanPrio 1.3.6.1.4.1.164.6.2.15.6.1.1.37
VLAN priority for P2P keep alive messages .
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtIpParamRingAdjacentMacAddr 1.3.6.1.4.1.164.6.2.15.6.1.1.38
The MAC address of the adjacent NE connected to this port in an ETH ring. If the port is not a member of a ring, the value of this parameter will be 00-00-00-00-00-00.
Status: current Access: read-only
OBJECT-TYPE    
  MacAddress  

prtClkSrc 1.3.6.1.4.1.164.6.2.15.7
OBJECT IDENTIFIER    

prtClkSrcTable 1.3.6.1.4.1.164.6.2.15.7.1
A table - Parameters for master and fallback clock source of ports .
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtClkSrcEntry

prtClkSrcEntry 1.3.6.1.4.1.164.6.2.15.7.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtClkSrcEntry  

prtClkSrcCnfgIdx 1.3.6.1.4.1.164.6.2.15.7.1.1.1
This attribute indicates the Idx of the Cnfg(1..255) being accessed ; Idx of 255 relates to the TmpCnfg.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..255  

prtClkSrcPrtIdx 1.3.6.1.4.1.164.6.2.15.7.1.1.2
This object indicates a unique Port Index (receiving clock). Refer to device specification for port Index
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

prtClkSrcIdx 1.3.6.1.4.1.164.6.2.15.7.1.1.3
An index in the table. master - refers Master clock parameters fallback - refers Fallback clock parameters
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER master(1), fallback(2)  

prtClkSrcMode 1.3.6.1.4.1.164.6.2.15.7.1.1.4
This entry indicates the source the nodal timing is locked to.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER internal(2), rxClk(3), notApplicable(255)  

prtClkSrcPrt 1.3.6.1.4.1.164.6.2.15.7.1.1.5
This entry is valid only when working in rxClk mode. It specifies the port from which the clock willl be taken. Refer to device specification for source port Index
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

opticalPort 1.3.6.1.4.1.164.6.2.15.8
OBJECT IDENTIFIER    

optPrtMonitorTable 1.3.6.1.4.1.164.6.2.15.8.1
A table - optical port (e.g SFP) monitoring parameters, according to SFF-8472 Specification for Diagnostic Monitoring Interface for Optical Xcvrs. and ITU-T rec. G.958
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OptPrtMonitorEntry

optPrtMonitorEntry 1.3.6.1.4.1.164.6.2.15.8.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  OptPrtMonitorEntry  

optPrtMonitorPrtIdx 1.3.6.1.4.1.164.6.2.15.8.1.1.1
This object indicates a unique (optical) Port Index . Refer to device specification for port Index.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

optPrtMonitorSample 1.3.6.1.4.1.164.6.2.15.8.1.1.2
This index indicates historic and current values - minimum, maximum and actual (current) value.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER actual(1), minimum(2), maximum(3)  

optPrtMonitorTxPower 1.3.6.1.4.1.164.6.2.15.8.1.1.3
Transmitted optical power level. Value is given in units of hundredth (1/100) of dBm.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optPrtMonitorLaserBias 1.3.6.1.4.1.164.6.2.15.8.1.1.4
LASER bias current level. Value is given in units of microAmper (uA).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optPrtMonitorLaserTemp 1.3.6.1.4.1.164.6.2.15.8.1.1.5
LASER temperature level, in hundredth (1/100) (C) degrees.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optPrtMonitorRxPower 1.3.6.1.4.1.164.6.2.15.8.1.1.6
Received optical power in units of hundredth (1/100) of dBm.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optPrtMonitorSupplyVoltage 1.3.6.1.4.1.164.6.2.15.8.1.1.7
Supply voltage, in hundredth (1/100) of volts (V).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optPrtCnfgTable 1.3.6.1.4.1.164.6.2.15.8.2
A table - optical port configuration
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OptPrtCnfgEntry

optPrtCnfgEntry 1.3.6.1.4.1.164.6.2.15.8.2.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  OptPrtCnfgEntry  

optPrtCnfgIdx 1.3.6.1.4.1.164.6.2.15.8.2.1.1
This attribute indicates the Idx of the Cnfg(1..255) being accessed ; Idx of 255 relates to the TmpCnfg.x.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

optPrtCnfgPrtIdx 1.3.6.1.4.1.164.6.2.15.8.2.1.2
This object indicates a unique (optical) Port Index . Refer to device specification for port Index.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

optPrtCnfgALS 1.3.6.1.4.1.164.6.2.15.8.2.1.3
enable/disable Automatic Laser Shutdown
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

systemResetAllStatsCmd 1.3.6.1.4.1.164.6.2.16
Reset statistics of all ports and connections of the device.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

systemClearTablesCmd 1.3.6.1.4.1.164.6.2.17
tempCnfgTables - Set *RowStatus = destroy for all entries of some tables having *RowStatus object, for temporary configuration only! (255). For the relevant tables, see product's specification. This object should be used by WAN product applications before performing the Update operation, in order to clear old entries of these tables. For MP-104/204 the entries will be destroyed for cnfg=1. off - agent will automatically change to this value, after performing the command.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), tempCnfgTables(3)  

systemParameter 1.3.6.1.4.1.164.6.2.18
This parameter can be used for different purposes: - TELNET session time-out in seconds. - Ace20: when trying to create row in a table that already has row with the same values, if set of values has to be unique in table, this attribute is set to the index of the existing row. - Optimux-T3: when CH interfaces are RJ-45, user can select via this object, the interface type for each Group of channels: T1 or E1: The selection will be a sum of the following Bits. '0' = T1 '1' = E1 Bit Group Value for each Bit having '1' 1 1 (CH-1..CH-8) 1 2 2 (CH-9..CH-12) 2 3 3 (CH-13..CH-20) 4 4 4 (CH-21..CH-28) 8 Examples: 15 = all Groups are selected to be E1 6 = Group 2 and Group 3 are selected to be E1 (Group 1 and Group 4 are T1). - FCD-A, FCD-M: user can select via this object the configuration used for Get values of MSDSL parameters that don't have configuration index. 1 =active configuration 255=temporary configuration. Set of this object should be done before Getting the MSDSL RW parameters. - Ace2002: This parameter indicates the number of intervals that were successfully uploaded upon statistics collection session. - FCD-IP, WR, FCD-IPD, LA-240: This parameter indicates whether Telnet Access is enabled/disabled: Values: 2 - Telnet Access is Disabled. 3 - Telnet Access is Enabled. -Vmux-110: This parameter value equals to maximum number of bundles. -Optimux-155: Simmilar usage to Optimux T3. user can select via this object, interface type T1 or E1 for each Group of channels (LIU): LIU group consists of 7 channels. Up to 12 LIUs are represented (84 T1 Channels). The selection will be a sum of the 2**n For each bit:'0' = T1 ,'1' = E1 Bit Group 1 1 (CH-1 .. CH-7) 2 2 (CH-8 .. CH-14) 3 3 (CH-15 ..CH-21) ... 9 9 (CH-56.. CH-63) ... 10 10 (CH-64..CH-70) 11 11 (CH-71..CH-77) 12 12 (CH-78..CH-84)
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

agnGlobalAlarmMask 1.3.6.1.4.1.164.6.2.19
The value of this attribute determines the alarm traps the agent should mask and not send to the managers. Each bit from a certain octet represents a certain alarm.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

alarmSeverity 1.3.6.1.4.1.164.6.2.20
This object specifies the severity of the alarms.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER event(3), minor(4), major(5), warning(6), critical(7)  

alarmState 1.3.6.1.4.1.164.6.2.21
.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(2), on(3)  

agnTestStatus 1.3.6.1.4.1.164.6.2.22
Indicates the current test status (for all levels: system, card, port). This attribute will be set to: on(3): when there is at least one test in progress on the system/card/port off(2): when there is NO test in progress on the system/card/port
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(2), on(3)  

systemSaveAndResetAllStatsCmd 1.3.6.1.4.1.164.6.2.23
on - a command to Save data of Current Period in Last Period data-set and start a new counting period for Current Period. off - agent will automatically change to this value, after performing the command.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

systemDefaultGateway 1.3.6.1.4.1.164.6.2.24
Default Gateway's IP Address.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

systemPsTable 1.3.6.1.4.1.164.6.2.25
This table describes the PS types of a device. Usage of this table is specified in the device's NMS SRS
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SystemPsEntry

systemPsEntry 1.3.6.1.4.1.164.6.2.25.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SystemPsEntry  

systemPsIndex1 1.3.6.1.4.1.164.6.2.25.1.1
First Index. In HUBs: 1 = PS-A slot 2 = PS-B slot 3 = PS-C slot. In SA units: 1 = PS1 2 = PS2 Default = 1
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

systemPsIndex2 1.3.6.1.4.1.164.6.2.25.1.2
Second Index. In HUBs: 1 always. In SA units: 1 = Local 2 = Remote Default = 1.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

systemPsType 1.3.6.1.4.1.164.6.2.25.1.3
The type of PS, for a stand-alone product. acDc - PS that supports both AC and DC. acPF - Power Feeding (phantom) box that is feeding another box by external AC. dcPF - Power Feeding (phantom) box that is feeding another box by external DC.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(1), ac(2), dc(3), acDc(4), acPF(5), dcPF(6)  

systemPsStatus 1.3.6.1.4.1.164.6.2.25.1.4
The Status of the PS unit.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), failed(2), ok(3), degraded(4)  

systemPsHotSwap 1.3.6.1.4.1.164.6.2.25.1.5
Is PS unit hot swap or fixed.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), fixed(2), hotSwap(3)  

agnFans 1.3.6.1.4.1.164.6.2.26
This entry specifies the FANs existence and status. Each fan will be represented by 2 bits, where the first bit (right) will specify the existence: (0= Not exist, 1=exist), and the left bit will specify it's status (0= OK, 1=FAIL), so for each fan: 00 - FAN does not exist 01 - FAN exists and OK (Low Mode) 10 - High Mode (FAN OK) 11 - FAN exists and is Failed bits 0-1 are for first fan bits 2-3 are for 2nd fan (if exists) bits 4-5 are for 3nd fan (if exists) bits 6-7 are for 4nd fan (if exists) bits 8-9 are for 5nd fan (if exists) bits 10-11 are for 6nd fan (if exists) bits 12-13 are for 7nd fan (if exists) bits 14-15 are for 8nd fan (if exists).
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

agnSendTrapParameter 1.3.6.1.4.1.164.6.2.27
This object specifies if the agent will attach a specific parameter to a trap. For ACE2002 the agent will attach or not the openViewSeverity parameter according to the value of this parameter: 1 - will attach openViewSeverity. 0 - will not attach openViewSeverity.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

agnSensorsStatus 1.3.6.1.4.1.164.6.2.28
This entry specifies the Sensors (Temperature sensors or others) existence and status. Each sensor will be represented by 2 bits, where the first bit (right) will specify the existence: (0= Not exist, 1=exist), and the left bit will specify it's status (0= OK, 1=FAIL), so for each sensor: 00 - sensor does not exist 01 - sensor exists and status is OK 11 - sensor exists and status is not OK ( e.g. temperature exceeds pre-defined threshold) bits 0-1 are for first sensor bits 2-3 are for 2nd sensor (if exists) and so on... Bit 0 is the LSB.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

agnStationClockCard 1.3.6.1.4.1.164.6.2.29
This entry specifies the station clock card existence and status. notExist - station clock card (piggy) does not exist. notValid - station clock card exists but clock status is not valid. ok - station clock card exists, and its status is OK When the sepcific reason for clock status not being valid is known, it may be reported by lossOfSync or lossOfSignal values.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), notExist(2), notValid(3), ok(4)  

xcIndexNext 1.3.6.1.4.1.164.6.2.30
This object contains an appropriate value to be used for xcIndex when creating entries in the xcTable. The value 0 indicates that no unassigned entries are available. To obtain the xcIndex value for a new entry, the manager issues a management protocol retrieval operation to obtain the current value of this object. After each retrieval, the agent should modify the value to the next unassigned index. After a manager retrieves a value the agent will determine through its local policy when this index value will be made available for reuse.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..2147483647  

xcTable 1.3.6.1.4.1.164.6.2.31
Configuration of system cross-connect entries. The table follows the behavior described in RFC 2515, RFC 1604 regarding the creation deletion and modification of an entry within the table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    XcEntry

xcEntry 1.3.6.1.4.1.164.6.2.31.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  XcEntry  

xcIndex 1.3.6.1.4.1.164.6.2.31.1.1
Cross Connect Identifier.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

xcIfIndex1 1.3.6.1.4.1.164.6.2.31.1.2
The interface Index from the ifTable, which identify one side of the connection.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

xcVpi 1.3.6.1.4.1.164.6.2.31.1.3
The VPI value.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

xcVci 1.3.6.1.4.1.164.6.2.31.1.4
The VCI value.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

xcIfIndex2 1.3.6.1.4.1.164.6.2.31.1.5
The interface Index from the ifTable, which identifies the other side of the connection.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

xcRowStatus 1.3.6.1.4.1.164.6.2.31.1.6
This parameter allows NMS to create/delete entries of this table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

xcDescr 1.3.6.1.4.1.164.6.2.31.1.7
A textual string containing information about the xc entry.
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString  

xcAdminStatus 1.3.6.1.4.1.164.6.2.31.1.8
The desired administrative status of this bi-directional cross-connect.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER up(1), down(2)  

xcOperStatus 1.3.6.1.4.1.164.6.2.31.1.9
The operational status of this bi-directional cross-connect.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER up(1), down(2), unknown(3)  

xcAttachedIfType 1.3.6.1.4.1.164.6.2.31.1.10
This object indicates if the specific VCC is already attached to any interface, and indicates the type of the interface. This object's purpose is to ease the checking to the NMS. notApplicable - used for entries that are not LAN (as HDLC), or when the VCC was attached to a bridge, or when this parameter is irrelevant. free - the LAN VCC wasn't attached yet to any router interface. routerAtm - attached to an ATM router interface. lis - attached to a LIS interface.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), free(2), routerAtm(3), lis(4)  

xcInputPriority 1.3.6.1.4.1.164.6.2.31.1.11
This object is the priority, by which the LAN frames will be internaly sent to the ATM HW. This parameter is applicable if atmNteMdlInputPriorityMechanism=enabled. 1 - Highest priority. Will be the first to be sent to the ATM HW. 4 - Lowest priority. Will be the last to be sent to the ATM HW.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 1..4  

xcBitMapping 1.3.6.1.4.1.164.6.2.31.1.12
This object maps this entry to a bit of an octet string. For ACE2002 this object maps the LAN VCC to the bit of the VLAN Port Lists. If the value is '0' then it means that this VCC is not mapped to a port list or it may be an HDSL entry.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

systemModule 1.3.6.1.4.1.164.6.2.32
OBJECT IDENTIFIER    

modlParam 1.3.6.1.4.1.164.6.2.32.1
OBJECT IDENTIFIER    

modlParamTable 1.3.6.1.4.1.164.6.2.32.1.1
This table include parameters for system modules.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ModlParamEntry

modlParamEntry 1.3.6.1.4.1.164.6.2.32.1.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  ModlParamEntry  

modlParamIndex 1.3.6.1.4.1.164.6.2.32.1.1.1.1
The module index. The index can be the slot number or any other module index as described in the specifications of the device. For Vmux-2100 device, the index will have values of: 1..4 for slots 1..4.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

modlParamReset 1.3.6.1.4.1.164.6.2.32.1.1.1.2
Reset action to be performed on the module. Set the parameter will be done always to on(3) or factory (4). After performing the Reset operation, Agent will automatically set the parameter to off(2).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3), factory(4)  

modlParamSwdlStatus 1.3.6.1.4.1.164.6.2.32.1.1.1.3
This parameter indicates whatever the swdl is in process or not.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), off(2), inProcess(3)  

modlParamLeds 1.3.6.1.4.1.164.6.2.32.1.1.1.4
This entry specifies the LEDs status of the module. Each led is represented by 4 bits where the first 2 bits (left) specify the status : (00=NA, 01=OFF, 10=ON, 11=BLINK), and the next two bits (right) specify the color : (00=GREEN, 01=RED, 10=YELLOW, 11=GRAY). The order of the LEDS is from top to bottom, left to right: For each row starting from the top, the LEDS are returned from left to right.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

modlParamType 1.3.6.1.4.1.164.6.2.32.1.1.1.5
This attribute indicates the Module Type.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(2), empty(3), miRicE1(4), miRicT1(5), miRicE3(6), miRicT3(7)  

modlParamSwVer 1.3.6.1.4.1.164.6.2.32.1.1.1.6
This attribute indicates the Module's Software Version.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

agnNearFarConnection 1.3.6.1.4.1.164.6.2.33
This parameter describes the connection between near-end and far-end agents.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), disconnected(2), connected(3)  

agnAccess 1.3.6.1.4.1.164.6.2.34
OBJECT IDENTIFIER    

agnTelnetAccess 1.3.6.1.4.1.164.6.2.34.1
Enable/Disable accessing the device via Telnet. disable - no one will be allowed to access the device via Telnet. enable - all users are allowed Telnet Access. managersOnly - Only manager stations listed in the manager's list are allowed. enableSecure - same as 'enable' above + only Secure data will be accepted (SSH) managersOnlySecure - same as 'managersOnly' above + only Secure data will be accepted (SSH).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(2), enable(3), managersOnly(4), enableSecure(5), managersOnlySecure(6)  

agnWebAccess 1.3.6.1.4.1.164.6.2.34.2
Enable/Disable accessing the device via Web. disable - no one will be allowed to access the device via Web. enable - all users are allowed Web Access. managersOnly - Only manager stations listed in the manager's list are allowed. enableSecure - same as 'enable' above + only Secure data will be accepted (SSL) managersOnlySecure - same as 'managersOnly' above + only Secure data will be accepted (SSL).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(2), enable(3), managersOnly(4), enableSecure(5), managersOnlySecure(6)  

agnRadiusAccess 1.3.6.1.4.1.164.6.2.34.3
Enable/Disable authentication via RADIUS server.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(2), enable(3)  

agnSshAccess 1.3.6.1.4.1.164.6.2.34.4
Enable/Disable accessing the device via SSH. disable - no one will be allowed to access the device via SSH. enable - all users are allowed SSH Access. managersOnly - Only manager stations listed in the manager's list are allowed.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(2), enable(3), managersOnly(4)  

systemInterface 1.3.6.1.4.1.164.6.2.35
OBJECT IDENTIFIER    

ifCreateTable 1.3.6.1.4.1.164.6.2.35.1
The Interface Configuration Table. This table enables to create interfaces of Entities.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IfCreateEntry

ifCreateEntry 1.3.6.1.4.1.164.6.2.35.1.1
An entry in the Interface Configuration table.
Status: current Access: not-accessible
OBJECT-TYPE    
  IfCreateEntry  

ifCreateEntityType 1.3.6.1.4.1.164.6.2.35.1.1.1
This object indicates the Type of the Entity that exists above the created interface. For a Logical Port, this value can be: other (1) when there is no fixed entity above it.
Status: current Access: read-only
OBJECT-TYPE    
  SysIfEntityType  

ifCreateEntityIdx 1.3.6.1.4.1.164.6.2.35.1.1.2
This object indicates the Index of the Entity that exists above the created interface. For a Logical Port, this value can be: 9999 - N/A when there is no fixed entity above it.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ifCreateNumber 1.3.6.1.4.1.164.6.2.35.1.1.3
This object indicates the number of the Interface that is created.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ifCreateRowStatus 1.3.6.1.4.1.164.6.2.35.1.1.4
This object enables the user to create/delete entries in this table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

ifCreateType 1.3.6.1.4.1.164.6.2.35.1.1.5
This object indicates the Type of the Interface that is created.
Status: current Access: read-create
OBJECT-TYPE    
  IANAifType  

ifCreateIndex 1.3.6.1.4.1.164.6.2.35.1.1.6
This object indicates the ifIndex of the created Interface. The ifIndex is assigned by the device.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ifCreateConnectedTo 1.3.6.1.4.1.164.6.2.35.1.1.7
This object indicates the entity connected to the created Interface. The value of this object can be ifIndex of the connected entity or any other number that can identify it.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

ifCreateParams 1.3.6.1.4.1.164.6.2.35.1.1.8
This object represents one or more parameters of the created Interface. Each group of bits (one or more bits) represents a specific parameter and its possible values. This object's mapping and interpretation will be specified in each device's specification documents. The parameter should be used within the create PDU assuming atomic operation.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

ifCreateConnectionPointer 1.3.6.1.4.1.164.6.2.35.1.1.9
This parameter represents the entity that is connected to this Interface. It can be used instead of ifCreateConnectedTo. It is an OBJECT IDENTIFIER. This parameter's SYNTAX allows the following possibilities: - can be simply used for entity that is not an interface - is not limited to include up to 32 bits The value of this parameter is a pointer to an existing row of a table, where the entity connected to this Interface is defined (i.e. the pointer uniquely identifies the connected entity). Examples: In case of an interface (from 2863.ifTable): points to 'ifEntry' of corresponding row = . In case of a VPI/VCI (from 2515.atmVclTable): points to 'atmVclEntry' of corresponding row = ..VPI.VCI In case no entity is connected, value = 0 .
Status: current Access: read-create
OBJECT-TYPE    
  RowPointer  

interfacePerformance 1.3.6.1.4.1.164.6.2.35.2
OBJECT IDENTIFIER    

ifPerfTable 1.3.6.1.4.1.164.6.2.35.2.1
Interface Performance Table. The propose of this table is to support statistics counters having 64 bit by using 2 parameters with syntax= Integer32. This is because SNMPv1 does not support Counter64 properly. For SNMPv3, ifPerfHCCounter (Counter64) may be supported.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IfPerfEntry

ifPerfEntry 1.3.6.1.4.1.164.6.2.35.2.1.1
An entry in the Interface Performance Table.
Status: current Access: not-accessible
OBJECT-TYPE    
  IfPerfEntry  

ifPerfCounterType 1.3.6.1.4.1.164.6.2.35.2.1.1.1
2nd index of the ifPerfTable. This parameter represents the Counter Type. Each application can have a different association between this object's value and counter type - see relevant application spec. For VPLS-MTU application use the following values: 1= Rx Octets, 2= Tx Octets, 3= Rx Frames, 4= Tx Frames, 5=Rx Dropped Frames, 6= Tx Dropped Frames. Optionally, counter type description appears in agnListDecodingTable
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

ifPerfLowCounterPart 1.3.6.1.4.1.164.6.2.35.2.1.1.2
In order to support Counters having 64 bit length, the performance counter is divided into two 32 bit parameters as follows: [ 64 bit parameter ] = [ High 32 bit parameter ][ Low 32 bit parameter ]. This parameter holds the Low 32 bits of the counter, while the following parameter holds the High 32 bits of the counter.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

ifPerfHighCounterPart 1.3.6.1.4.1.164.6.2.35.2.1.1.3
This parameter holds the High 32 bits of the counter (see description in the above parameter).
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

ifPerfHCCounter 1.3.6.1.4.1.164.6.2.35.2.1.1.4
This High Capacity counter holds whole 64 bits of the counter indicated by ifPerfCounterType (concatenates both counter parts ifPerfHighCounterPart&ifPerfLowCounterPart) This object can be supported only by agents using SNMPv2 or SNMPv3.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

systemOam 1.3.6.1.4.1.164.6.2.36
OBJECT IDENTIFIER    

systemOamTable 1.3.6.1.4.1.164.6.2.36.1
The OAM Configuration Table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SystemOamEntry

systemOamEntry 1.3.6.1.4.1.164.6.2.36.1.1
An entry in the OAM table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SystemOamEntry  

systemOamCnfgIdx 1.3.6.1.4.1.164.6.2.36.1.1.1
This attribute indicates the Idx of the Cnfg(1..255) being accessed ; Idx of 255 relates to the TmpCnfg.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..255  

systemOamFrequency 1.3.6.1.4.1.164.6.2.36.1.1.2
Time in sec. between 2 OAM packets.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

systemOamTimeoutCycles 1.3.6.1.4.1.164.6.2.36.1.1.3
No. of cycles the agent will send OAM packets without receiving a response from the remote device before declaring that the connection to the remote side is down - Time Out.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

systemOamLinkCheck 1.3.6.1.4.1.164.6.2.36.1.1.4
This MIB object determines whether continuous connectivity Link checks will be performed by the device for uplinks. For Vmux-2100: enable (3) value can be set upon device installation. In this case, TDM Link Connectivity checks can be performed even before the user configures the Links of the device.If the value is enable (3) and there is no connection with the remote side, the Test LED will blink on the Main Board Module.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(2), enable(3)  

systemOamDescrTable 1.3.6.1.4.1.164.6.2.36.2
The OAM Descriptors Configuration Table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SystemOamDescrEntry

systemOamDescrEntry 1.3.6.1.4.1.164.6.2.36.2.1
An entry in the OAM table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SystemOamDescrEntry  

systemOamDescrIdx 1.3.6.1.4.1.164.6.2.36.2.1.1
The OAM Descriptor Index.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

systemOamDescrRowStatus 1.3.6.1.4.1.164.6.2.36.2.1.2
Enables the user to create/delete entries in this table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

systemOamDescrMode 1.3.6.1.4.1.164.6.2.36.2.1.3
The OAM Mode of the Descriptor.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER intermediate(1), segmentTermination(2), endToEndTermination(3)  

systemOamDescrCCDirection 1.3.6.1.4.1.164.6.2.36.2.1.4
OAM Continuity Check function mode. both(2) - Agent sends OAM CC cells and checks received OAM CC cells. none(3) - Agent does not send and does not check received OAM CC cells. source(4)- Agent sends OAM CC cells. sink(5) - Agent checks received OAM CC cells.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER both(2), none(3), source(4), sink(5)  

systemOamDescrLoopbackOperation 1.3.6.1.4.1.164.6.2.36.2.1.5
The OAM Loopback function mode. off(2) - Stop sending loopback OAM cells. on(3) - Start loopback OAM cells.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER off(2), on(3)  

systemOamDescrLoopbackDestAddr 1.3.6.1.4.1.164.6.2.36.2.1.6
Loopback Destination Address.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING  

systemOamDescrXcCounter 1.3.6.1.4.1.164.6.2.36.2.1.7
The number of connections that use this OAM Descriptor.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

agnDeviceView 1.3.6.1.4.1.164.6.2.37
This variable denotes the view of the device: Look: old look, new look or new look 2. Material: Plastic or Metal.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER oldLook(2), newLook(3), newLook2(4), plastic(5), metal(6)  

bitMappingTable 1.3.6.1.4.1.164.6.2.38
This table maps bits of an octet string to an interface. For ACE-2002 this table is used to map bits of VLAN port lists to LAN VCC's. This table is the opposite view of the xcTable for xcBitMapping. It is used to ease the bit translation for the NMS.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    BitMappingEntry

bitMappingEntry 1.3.6.1.4.1.164.6.2.38.1
Each entry in the table describes a correlation of a bit location to an interface. For ACE-2002 - Upon creation of a new LAN VCC the agent will add an entry to this table that will define the bit location for that VCC.
Status: current Access: not-accessible
OBJECT-TYPE    
  BitMappingEntry  

bitMappingLocation 1.3.6.1.4.1.164.6.2.38.1.1
The bit location in an octet string.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

bitMappingIndex 1.3.6.1.4.1.164.6.2.38.1.2
The interface index or any other index that should be mapped.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

bitMappingView 1.3.6.1.4.1.164.6.2.39
A view of the bitMappingTable in one object - each entry in the biMappingTable will have the corresponding Bit of this object (bitMappingLocation) = '1'. For ACE-2002 it is used to describe all the existing LAN VCC's So that the NMS can easily calculate which VCC's can be selected as members for a VLAN, instead of reading all the bitMapping Table.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

hostTable 1.3.6.1.4.1.164.6.2.40
Host interface table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HostEntry

hostEntry 1.3.6.1.4.1.164.6.2.40.1
An entry in the Host Table. The hostParam1, hostParam2, and hostParam3 entries may have different use in different applications.
Status: current Access: not-accessible
OBJECT-TYPE    
  HostEntry  

hostIndex 1.3.6.1.4.1.164.6.2.40.1.1
The Host Table Index. This index can have the same value as Host No.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

hostIP 1.3.6.1.4.1.164.6.2.40.1.2
The host interface IP address.
Status: current Access: read-create
OBJECT-TYPE    
  IpAddress  

hostIPMask 1.3.6.1.4.1.164.6.2.40.1.3
The host interface subnet mask.
Status: current Access: read-create
OBJECT-TYPE    
  IpAddress  

hostDefaultNextHop 1.3.6.1.4.1.164.6.2.40.1.4
The host interface Default Next Hop address.
Status: current Access: read-create
OBJECT-TYPE    
  IpAddress  

hostMode 1.3.6.1.4.1.164.6.2.40.1.5
This parameter represents the Host mode of operation. There can be different values for each application. For example: Not Applicable = 1.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

hostParam1 1.3.6.1.4.1.164.6.2.40.1.6
This parameter represents the first Host parameter. There can be different values for each application. For example: Not Applicable = 1.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

hostParam2 1.3.6.1.4.1.164.6.2.40.1.7
This parameter represents the 2nd Host parameter. There can be different values for each application.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

hostParam3 1.3.6.1.4.1.164.6.2.40.1.8
This parameter represents the 3nd Host parameter. There can be different values for each application.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

hostRowStatus 1.3.6.1.4.1.164.6.2.40.1.9
Creation/Deletion of rows in the table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

hostVlanTagging 1.3.6.1.4.1.164.6.2.40.1.10
Host VLAN support (Tagging). untag - No support of VLAN Tagging. tag - 4 VLAN bytes will be added to the frame.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER notApplicable(1), untag(2), tag(3)  

hostVlanId 1.3.6.1.4.1.164.6.2.40.1.11
Host VLAN ID.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

hostVlanPriority 1.3.6.1.4.1.164.6.2.40.1.12
Host VLAN Frame priority.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

invNameXCTable 1.3.6.1.4.1.164.6.2.41
Inverse Name XC Table. This table can be used to ease the search for a connection first index by the connection name.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    InvNameXCEntry

invNameXCEntry 1.3.6.1.4.1.164.6.2.41.1
An entry in the table.
Status: current Access: not-accessible
OBJECT-TYPE    
  InvNameXCEntry  

invNameXC 1.3.6.1.4.1.164.6.2.41.1.1
The unique Connection name, associated to a Cross-Connection.
Status: current Access: not-accessible
OBJECT-TYPE    
  SnmpAdminString Size(1..64)  

invNameXCType 1.3.6.1.4.1.164.6.2.41.1.2
The OBJECT IDENTIFIER of the respective XC Table. Examples: XC Table invNameXCType --------------------------------------------------- atmVpCrossConnectTable 1.3.6.1.2.1.37.1.9 atmVcCrossConnectTable 1.3.6.1.2.1.37.1.11 atmfCESConfTable 1.3.6.1.4.1.353.5.2.2.1.1 .
Status: current Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

invNameXCIndex 1.3.6.1.4.1.164.6.2.41.1.3
The XC Table (invNameXCType) may include more than one index. This object represents the value of the first XC Index.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

agnDeviceCapabilities 1.3.6.1.4.1.164.6.2.42
Indicates the optional capabilities that are implemented by this device and are manageable through this MIB. For each capability 1 BIT is allocated in each Octet starting from the LSB. If the value of the BIT = 1, the capability is Enabled. If the value of the BIT = 0, the capability is Disabled. For bit assignment, refer to device specification. Capabilities example: Router - BIT 0 (0000 0001 = 01 Hex = 1 Decimal). The 2nd octet (MSB) will represent the maximum number of intervals that the Agent can keep in its DB (same for all ports). For Vmux, this object describes agent's support of LBRAD coder feature: 1 octet ; bit 0 (LSB). '1' - LBRAD feature is supported '0' - LBRAD feature is not supported.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

rowInfoTable 1.3.6.1.4.1.164.6.2.43
This table holds information of other tables.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RowInfoEntry

rowInfoEntry 1.3.6.1.4.1.164.6.2.43.1
An entry in the table.
Status: current Access: not-accessible
OBJECT-TYPE    
  RowInfoEntry  

rowInfoTableId 1.3.6.1.4.1.164.6.2.43.1.1
The OBJECT IDENTIFIER of the Table, which its information is held by this table (rowInfoTable). Examples: Table Name rowInfoTableId --------------------------------------------------- atmTrafficDescrParamTable 1.3.6.1.2.1.37.1.5 atmVpCrossConnectTable 1.3.6.1.2.1.37.1.9 atmVcCrossConnectTable 1.3.6.1.2.1.37.1.11 atmfCESConfTable 1.3.6.1.4.1.353.5.2.2.1.1 .
Status: current Access: not-accessible
OBJECT-TYPE    
  OBJECT IDENTIFIER  

rowInfoCounter 1.3.6.1.4.1.164.6.2.43.1.2
The Number of rows in the table, indicated by rowInfoTableId.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

rowInfoIndexNext 1.3.6.1.4.1.164.6.2.43.1.3
The First Free Index of the table, indicated by rowInfoTableId.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

rowInfoMaxNoOfRows 1.3.6.1.4.1.164.6.2.43.1.4
The maximum possible number of rows in the table, indicated by rowInfoTableId.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

agnStoreCmd 1.3.6.1.4.1.164.6.2.44
Store command. inFlash(3) = store the current Agent configuration in Flash memory. asDefConfigFile(4) = store the current Agent configuration as Default Configuration file (e.g. 'DefConfig.cfg'). Agent will perform the required command and change automatically the value of this object to off(2).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), inFlash(3), asDefConfigFile(4)  

agnFunctionTable 1.3.6.1.4.1.164.6.2.45
This table is used in order to activate/deactivate device functions. The index indicates the function. Each function can be Enabled or Disabled.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnFunctionEntry

agnFunctionEntry 1.3.6.1.4.1.164.6.2.45.1
An entry in the table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AgnFunctionEntry  

agnFunction 1.3.6.1.4.1.164.6.2.45.1.1
This MIB object indicates the function that will be enabled or disabled in the device. alarmForwarding= Fault Propagation (usually towards user port). For Vmux: routing (2) - enable/disable Router backup (3) - enable/disable Backup between E1/T1/Serial Link and ETH. uplinkLoopDetect (5) - enable/disable Loop Detection on the TDM Uplink. systemClock (6) - enable/disable the System Clock.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER routing(2), backup(3), alarmForwarding(4), uplinkLoopDetect(5), systemClock(6)  

agnFunctionActivation 1.3.6.1.4.1.164.6.2.45.1.2
This MIB object indicates the activation of the current function.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(2), enable(3)  

agnManagerConfigPorts 1.3.6.1.4.1.164.6.2.46
This variable defines from which port/s this manager can manage the device. The value is a sum of 2**n, where n is a bit assigned to a certain port. For RIC-E1 and ETX 102 the value will be according to the ports combination: Network = bit 0 User= bit 1 For Example: All = 3.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

agnEgressRateRange 1.3.6.1.4.1.164.6.2.47
This variable defines the valid ranges of egress rate. For example, for ETX 102: range 1 (2)= 128KBPS - 8MBPS, range 2 (3)= 256KBPS - 16MBPS, range 3 (4)= 512KBPS - 32MBPS, range 4 (5)= 1MBPS - 64MBPS, range 5 (6)= 1.5MBPS - 80MBPS.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unlimited(1), range1(2), range2(3), range3(4), range4(5), range5(6), range6(7), range7(8)  

agnNoOfCurrentConns 1.3.6.1.4.1.164.6.2.48
This variable indicates the number of connections currently configured for the agent.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

agnIngressRateRange 1.3.6.1.4.1.164.6.2.49
This variable defines the valid ranges of ingress rate. For example, for ETX 102: range 1 (2)= 128KBPS - 8MBPS, range 2 (3)= 256KBPS - 16MBPS, range 3 (4)= 512KBPS - 32MBPS, range 4 (5)= 1MBPS - 64MBPS, range 5 (6)= 1.5MBPS - 80MBPS.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unlimited(1), range1(2), range2(3), range3(4), range4(5), range5(6), range6(7), range7(8)  

alarmForwardingTable 1.3.6.1.4.1.164.6.2.50
The Alarm Forwarding Mechanism will be operated for this table entries.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AlarmForwardingEntry

alarmForwardingEntry 1.3.6.1.4.1.164.6.2.50.1
Each entry in this table is a pair of ports that the Alarm Forwarding Mechanism is determined for.
Status: current Access: not-accessible
OBJECT-TYPE    
  AlarmForwardingEntry  

alarmForwardingFailPort 1.3.6.1.4.1.164.6.2.50.1.1
An Index of the port on which a fail occurs.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..2147483647  

alarmForwardingToPort 1.3.6.1.4.1.164.6.2.50.1.2
An Index of the port that will be affected upon the failure of the alarmForwardingFailPort.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..2147483647  

alarmForwardingRowStatus 1.3.6.1.4.1.164.6.2.50.1.3
Creation/ Deletion of rows in the table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

alarmForwardingRecoveryTime 1.3.6.1.4.1.164.6.2.50.1.4
This parameter defines the maximum time (sec) the affected port will hold the down state.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

alarmForwardingGroupConditions 1.3.6.1.4.1.164.6.2.50.1.5
This parameter is applicable when there is a group of interfaces in which a fault may occur, and one interface to which alarm is propagated (forwarded). 0 = All - Forwarding will take place only when all interfaces of the same group are faulty. 1 = Single - Forwarding will take place when at least one (single) interface of the same group (any of them) is faulty. n - forwarding will take place only when n (n < all) interfaces of the same group fail.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

alarmForwardingCause 1.3.6.1.4.1.164.6.2.50.1.6
Bit map representing the cause upon which alarm forwarding will take place. bit 0 - LOSS (LINE DOWN) bit 1 - AIS bit 2 - RDI bit 3 - PROTOCOL DOWN.
Status: current Access: read-create
OBJECT-TYPE    
  BITS loss(0), ais(1), rdi(2), protocolDown(3)  

alarmForwardingRecoveryMode 1.3.6.1.4.1.164.6.2.50.1.7
This parameter determines the Recovery Mode. manual - The user should stop the alarm forwarding by using the alarmForwardingRecoveryCommand. automatic - Alarm forwarding will be automatically stopped upon alarmForwardingFailPort recovery.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER manual(1), automatic(2)  

alarmForwardingRecoveryCommand 1.3.6.1.4.1.164.6.2.50.1.8
This parameter is a command. It is applicable when alarmForwardingRecoveryMode = manual. on - Will stop alarm forwarding. After setting to 'On', the agent will set this parameter back to 'Off'.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER off(2), on(3)  

alarmForwardingDelay 1.3.6.1.4.1.164.6.2.50.1.9
This parameter determines the period of time (in seconds) the alarm of the alarmForwardingFailPort should exist before starting alarm forwarding.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

alarmForwardingDirection 1.3.6.1.4.1.164.6.2.50.1.10
This parameter determines the Direction of the Alarm Forwarding. unidirectional - alarmForwardingFailPort affects the alarmForwardingToPort. bidirectional - alarmForwardingFailPort affects the alarmForwardingToPort AND vice-versa. For such cases, this value will be selected, instead of entering an additional unidirectional entry in the table, where the indexes are swapped.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER unidirectional(1), bidirectional(2)  

alarmForwardingAction 1.3.6.1.4.1.164.6.2.50.1.11
Bit map representing the action to be performed when alarm forwarding will take place. bit 0 - No Action. '1' value - device should NOT perform any action, though other bits indicate the action to be taken. '0' value - device should perform the action/s indicated by rest of the bits. In this case, one of the other bits should be '1'. bit 1 - Interface Deactivation (of the affected Port: alarmForwardingToPort) bit 2 - OAM Signaling. Affected Port (alarmForwardingToPort) will send special OAM Signaling to the Far-End unit about the Failure. This object will be used only for devices that support Deactivation per entry OR can support more than one action.
Status: current Access: read-create
OBJECT-TYPE    
  BITS noAction(0), interfaceDeactivation(1), oamSignaling(2)  

agnSwVersionSwapCmd 1.3.6.1.4.1.164.6.2.51
SW switch command. mainAndBackup (3) = Swap between Main SW and the backup one. Agent will perform the required command and change automatically the value of this object to off(2).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), mainAndBackup(3)  

agnClockSource 1.3.6.1.4.1.164.6.2.52
OBJECT IDENTIFIER    

agnClkSrcPortTable 1.3.6.1.4.1.164.6.2.52.1
Pool of Ports for the Master/Fallback Clock Source and of Recovered IDs. For devices with more than one configuration: Set operation is valid only to the TmpCnfg entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnClkSrcPortEntry

agnClkSrcPortEntry 1.3.6.1.4.1.164.6.2.52.1.1
An entry in the table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AgnClkSrcPortEntry  

agnClkSrcPortCnfgIdx 1.3.6.1.4.1.164.6.2.52.1.1.1
This object indicates the Idx of the Cnfg being accessed ; Idx of 255 relates to the TmpCnfg. For product supporting a single configuration, the value will be 1.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..2147483647  

agnClkSrcPortSrcIdx 1.3.6.1.4.1.164.6.2.52.1.1.2
Clock Source Index. master - refers to Master clock fallback - refers to Fallback clock recovered - refers to Recovered clock.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER master(1), fallback(2), recovered(3)  

agnClkSrcPortIdx 1.3.6.1.4.1.164.6.2.52.1.1.3
This object indicates the running Idx of the port that is to be used as Clock Source, for each agnClkSrcPortSrcIdx instance. In case of Recovered Clock - it indicates the Clock ID.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..2147483647  

agnClkSrcPort 1.3.6.1.4.1.164.6.2.52.1.1.4
This object indicates the Port/Interface Index of the port that is to be used as Clock Source. In case of Recovered Clock - it indicates the PW number.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 1..2147483647  

agnClkSrcPortRowStatus 1.3.6.1.4.1.164.6.2.52.1.1.5
This object enables Creation/ Deletion of rows in the table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

agnClkSrcPortAdminStatus 1.3.6.1.4.1.164.6.2.52.1.1.6
This object indicates the Recovered Clock Administrative Status.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER notApplicable(1), down(2), up(3)  

agnClkSrcPortType 1.3.6.1.4.1.164.6.2.52.1.1.7
This object is relevant only in case of Recovery Clock. It indicates the Clock Type.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER notApplicable(1), adaptive(2), ieee1588v2(3), commonClock(4)  

agnClkSrcPortQuality 1.3.6.1.4.1.164.6.2.52.1.1.8
This object indicates the Clock Source Quality.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER notApplicable(1), stratum1(2), stratum2(3), stratum3(4), stratum3e(5), stratum4(6)  

agnClkSrcPortNetType 1.3.6.1.4.1.164.6.2.52.1.1.9
This object is relevant only in case of Recovery Clock. It indicates the Clock Network Type, i.e. the PSN network characteristics and behavior.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER notApplicable(1), typeA(2), typeB(3), typeC(4), typeD(5), typeE(6), typeF(7)  

agnClkSrcPortState 1.3.6.1.4.1.164.6.2.52.1.1.10
This object indicates the Clock State. freeRun(1) - Clock recovery is not locked to any clock. frequencyAcquisition(2) - Adaptive clock recovery is learning the frequency. rapidPhaseLock(3) - Clock recovery is in training process till it reaches fine phase lock. finePhaseLock(4) - Clock is locked and clock recovery is qualified and stable. holdover(5) - Clock recovery is in holdover mode. notApplicable(6) - Clock recovery is not applicable. .
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER freeRun(1), frequencyAcquisition(2), rapidPhaseLock(3), finePhaseLock(4), holdover(5), notApplicable(6)  

agnCurrClkTable 1.3.6.1.4.1.164.6.2.52.2
Current Clock Source.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnCurrClkEntry

agnCurrClkEntry 1.3.6.1.4.1.164.6.2.52.2.1
An entry in the table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AgnCurrClkEntry  

agnCurrClkObjIdx 1.3.6.1.4.1.164.6.2.52.2.1.1
This MIB object identifies the object for which the Clock Source is used (System, Other System, Card).
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..2147483647  

agnCurrClkMode 1.3.6.1.4.1.164.6.2.52.2.1.2
Current Clock Source Mode. master - refers Master clock fallback - refers Fallback clock internal - only when both Master and Fallback Sources failed
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER master(1), fallback(2), internal(3)  

agnCurrClkSrc 1.3.6.1.4.1.164.6.2.52.2.1.3
This object indicates the Current Clock Source.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(1), internal(2), rxClk(3), station(4), lbt(5), ntr(6), adaptive(7), stationB(8), automatic(9), system(10), sSubsystem(11), notApplicable(255)  

agnCurrClkPort 1.3.6.1.4.1.164.6.2.52.2.1.4
This object indicates the Port/Interface Index of the port that is Currently used as Clock Source.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..2147483647  

agnCurrClkHoldover 1.3.6.1.4.1.164.6.2.52.2.1.5
Current Clock Holdover State. As a last resort, in the absence of higher quality timing: - a SONET/SDH object can enter 'holdover' state, until higher quality external timing becomes available again. In this state (value=yes) the SONET/SDH object uses its own timing circuits for clock of the SONET/SDH signal. - for other objects, the 'holdover'=yes state means that the object uses last available clock (stored by the object) for a pre-defined time, until another clock source is used.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

agnCurrClkSsmBased 1.3.6.1.4.1.164.6.2.52.2.1.6
This parameter indicates whether clock source is selected based on receive clock quality. Clock quality is indicated in S1 byte inside SONET/SDH overhead, (encoded as SSM - Synchronization Status Messaging).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

agnCurrClkState 1.3.6.1.4.1.164.6.2.52.2.1.7
This object indicates the Current Clock State. freeRun(1) - Current clock state machine is not locked and run from the internal oscillator. rapidPhaseLock(2) - Current clock state machine is locked. finePhaseLock(3) - Current clock state machine is in pre-locking. holdover(4) - Current clock state machine is in holdover mode (due to loss of event). .
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER freeRun(1), rapidPhaseLock(2), finePhaseLock(3), holdover(4)  

agnCurrClkQualification 1.3.6.1.4.1.164.6.2.52.2.1.8
This object indicates the Current Clock Qualification and defines whether the PLL can locked according to the stratum definitions.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), disqualified(2), qualified(3)  

agnClockMonitoring 1.3.6.1.4.1.164.6.2.52.3
OBJECT IDENTIFIER    

agnClkCurrentTable 1.3.6.1.4.1.164.6.2.52.3.1
The Clock Current table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnClkCurrentEntry

agnClkCurrentEntry 1.3.6.1.4.1.164.6.2.52.3.1.1
An entry in the Clock Current table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AgnClkCurrentEntry  

agnClkCurrentIndex 1.3.6.1.4.1.164.6.2.52.3.1.1.1
An Index that is uniquely represents the Clock.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

agnClkCurrentRxPackets 1.3.6.1.4.1.164.6.2.52.3.1.1.2
The counter associated with the number of Received Packets, encountered by a Bridge Port in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

agnClkCurrentLostPackets 1.3.6.1.4.1.164.6.2.52.3.1.1.3
The counter associated with the number of Lost Packets, encountered by a Bridge Port in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

agnClkCurrentOutOfOrderPackets 1.3.6.1.4.1.164.6.2.52.3.1.1.4
The counter associated with the number of times Out-of-Order Packets encountered by a Bridge Port in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

agnClkCurrentBufferUnderflow 1.3.6.1.4.1.164.6.2.52.3.1.1.5
The counter associated with the number of times Underflow event encountered by a Bridge Port in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

agnClkIntervalTable 1.3.6.1.4.1.164.6.2.52.3.2
The Clock Interval table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnClkIntervalEntry

agnClkIntervalEntry 1.3.6.1.4.1.164.6.2.52.3.2.1
An entry in the Clock Interval table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AgnClkIntervalEntry  

agnClkIntervalIndex 1.3.6.1.4.1.164.6.2.52.3.2.1.1
An Index that is uniquely represents the Clock.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

agnClkIntervalNumber 1.3.6.1.4.1.164.6.2.52.3.2.1.2
A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals exist).
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

agnClkIntervalRxPackets 1.3.6.1.4.1.164.6.2.52.3.2.1.3
The counter associated with the number of Received Packets, encountered by a Bridge Port in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

agnClkIntervalLostPackets 1.3.6.1.4.1.164.6.2.52.3.2.1.4
The counter associated with the number of Lost Packets, encountered by a Bridge Port in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

agnClkIntervalOutOfOrderPackets 1.3.6.1.4.1.164.6.2.52.3.2.1.5
The counter associated with the number of times Out-of-Order Packets are detected, encountered by a Bridge Port in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

agnClkIntervalBufferUnderflow 1.3.6.1.4.1.164.6.2.52.3.2.1.6
The counter associated with the number of times Underflow event is detected, encountered by a Bridge Port in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

agnMaxNoOfConns 1.3.6.1.4.1.164.6.2.53
This variable indicates the maximum number of connections that can be configured for the agent.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

lag 1.3.6.1.4.1.164.6.2.54
OBJECT IDENTIFIER    

lagTable 1.3.6.1.4.1.164.6.2.54.1
A table defining Link Aggregation Groups port association, and other parameters.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LagEntry

lagEntry 1.3.6.1.4.1.164.6.2.54.1.1
An entry in the LAG table.
Status: current Access: not-accessible
OBJECT-TYPE    
  LagEntry  

lagCnfgIdx 1.3.6.1.4.1.164.6.2.54.1.1.1
This object indicates the Idx of the Cnfg(1..255) being accessed ; Idx of 255 relates to the TmpCnfg.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 1..255  

lagIdx 1.3.6.1.4.1.164.6.2.54.1.1.2
This object indicates LAG unique index.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

lagPortMembers 1.3.6.1.4.1.164.6.2.54.1.1.3
The set of ports which are permanently assigned to the Link Aggregation Group. The default value of this object is a string of zeros.
Status: current Access: read-create
OBJECT-TYPE    
  PortList  

lagDistributionMethod 1.3.6.1.4.1.164.6.2.54.1.1.4
This object defines the criteria for the 802.3ad (LAG) to split the traffic between ports
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER portBased(2), oneToOne(3), sourceMac(4), destinationMac(5), sourceXorDestinationMac(6), sourceAndDestinationMac(7), sourceIp(8), destinationIp(9), sourceAndDestinationMacAndIp(10), roundRobin(11)  

lagRecoveryMode 1.3.6.1.4.1.164.6.2.54.1.1.5
This object defines whether traffic will be returned to a port after its recovery. This object is applicable only when lagDistributionMethod= oneToOne (3).
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER nonRevertive(2), revertive(3)  

lagWaitToRestore 1.3.6.1.4.1.164.6.2.54.1.1.6
This object defines traffic recovery time (in seconds) to the port after its recovery. This object is applicable only when lagRecoveryMode= revertive (3).
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..720  

lagRowStatus 1.3.6.1.4.1.164.6.2.54.1.1.7
This object enables user to create/delete entries of this table. Note: When using LAG standard package, this table is static, hence, only the values active(1), notInService(2) are used.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

lagShutDownDurationUponFlip 1.3.6.1.4.1.164.6.2.54.1.1.8
This object defines the duration (in seconds) the active port transmission is shut down after LAG Flip occurs. The transmission is shut down and then opened again (after the duration defined by this object), in order to cause the other side to flip to the new active port. 0=no shut-down. This object is applicable only when lagDistributionMethod=oneToOne(3) and mainly when each of the Links of our device is connected to a different device.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..30  

lagRdnMethod 1.3.6.1.4.1.164.6.2.54.1.1.9
This object defines the redundancy method.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER loadSharing(1), redundancy(2)  

lagLacpEnable 1.3.6.1.4.1.164.6.2.54.1.1.10
Enabling/Disabling the LACP for a LAG. The LACP will be enabled for all ports belonging to this LAG.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

lagStatTable 1.3.6.1.4.1.164.6.2.54.2
A table defining Link Aggregation Groups Redundancy. This table is applicable only when lagDistributionMethod = oneToOne.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LagStatEntry

lagStatEntry 1.3.6.1.4.1.164.6.2.54.2.1
An entry in the LAG Status table.
Status: current Access: not-accessible
OBJECT-TYPE    
  LagStatEntry  

lagStatForcePort 1.3.6.1.4.1.164.6.2.54.2.1.1
This object enables user to enforce the active port. 0 = No Enforcement; Otherwise the ifIndex of the port.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

lagStatActivePort 1.3.6.1.4.1.164.6.2.54.2.1.2
This object indicates the current active port. It is applicable only when lagDistributionMethod = oneToOne. The value is the ifIndex of the port. 0 = none of the ports is active.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

gfp 1.3.6.1.4.1.164.6.2.55
OBJECT IDENTIFIER    

gfpCnfgTable 1.3.6.1.4.1.164.6.2.55.1
Configuration table for GFP (General Framing Protocol).
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    GfpCnfgEntry

gfpCnfgEntry 1.3.6.1.4.1.164.6.2.55.1.1
An entry in the GFP configuration table.
Status: current Access: not-accessible
OBJECT-TYPE    
  GfpCnfgEntry  

gfpCnfgIdx 1.3.6.1.4.1.164.6.2.55.1.1.1
Index to GFP configuration table.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

gfpPayloadFcs 1.3.6.1.4.1.164.6.2.55.1.1.2
This object defines whether protocol header will include FCS.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(2), enable(3)  

gfpRxTxScramble 1.3.6.1.4.1.164.6.2.55.1.1.3
This object defines whether transmission will be scrambled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noScramble(1), rxTxScramble(2), rxOnlyScramble(3), txOnlyScramble(4)  

gfpVcatHeader 1.3.6.1.4.1.164.6.2.55.1.1.4
VCAT header is LCAS CONTROL packet as described in the G-7043. one control packet is transmitted in a period of 16 Multi frame
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

agnGroupTable 1.3.6.1.4.1.164.6.2.56
A table that enables associating components to Group/s (or removing components of a group). The Group Idx can then be used in other tables (e.g alarmForwardingTable).
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnGroupEntry

agnGroupEntry 1.3.6.1.4.1.164.6.2.56.1
An entry in the agnGroupTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  AgnGroupEntry  

agnGroupCnfgIdx 1.3.6.1.4.1.164.6.2.56.1.1
This object indicates the Idx of the Cnfg(1..255) being accessed ; Idx of 255 relates to the TmpCnfg.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 1..255  

agnGroupIdx 1.3.6.1.4.1.164.6.2.56.1.2
This object indicates a unique Group Index.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

agnGroupComponentIdx 1.3.6.1.4.1.164.6.2.56.1.3
This object indicates a unique Component Index that belongs to the Group defined by agnGroupIdx.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

agnGroupRowStatus 1.3.6.1.4.1.164.6.2.56.1.4
This object enables user to create/delete entries of this table. destroy - If a Group is used in another table, Agent may not allow destroying the entry/ies that belong to this Group Index.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

agnStatNoOfUploadedIntervals 1.3.6.1.4.1.164.6.2.57
This parameter indicates the Number of Intervals that were successfully collected and uploaded in the last statistics collection session.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

agnSyslog 1.3.6.1.4.1.164.6.2.58
OBJECT IDENTIFIER    

agnSyslogDeviceUdpPort 1.3.6.1.4.1.164.6.2.58.1
The UDP Port of the device, from which Syslog messages are sent. Default=514.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

agnSyslogFacility 1.3.6.1.4.1.164.6.2.58.2
A user defined SW module, task or function, from which Syslog messages are sent to the remote Server.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER local1(17), local2(18), local3(19), local4(20), local5(21), local6(22), local7(23)  

agnSyslogSeverityLevel 1.3.6.1.4.1.164.6.2.58.3
Device will send events equal or exceeding this severity level (configured by user).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER critical(1), major(2), minor(3), warning(4), event(5), info(6), debug(7)  

agnNetworkInterfaceType 1.3.6.1.4.1.164.6.2.59
This MIB object indicates the network interface type to be used by the device. It is used for devices that use only one network port type.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), t1(2), t3(3)  

agnTrapDelay 1.3.6.1.4.1.164.6.2.60
This variable enables the user to set a delay (in seconds) before a trap is sent. This delay will be used only for traps that need to be sent during device initialization. It is needed because the device connected to our device starts transmitting traps later. The delay starts from the end of the Boot process. The device will keep the init traps in the correct order, and cancel those which clear former ones in the list. After this init delay, traps will be sent without a delay.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

agnStringToIndexTable 1.3.6.1.4.1.164.6.2.62
This table holds the conversions of tables from unique String to numeric index.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnStringToIndexEntry

agnStringToIndexEntry 1.3.6.1.4.1.164.6.2.62.1
An entry in the table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AgnStringToIndexEntry  

agnStringToIndexTableId 1.3.6.1.4.1.164.6.2.62.1.1
The OBJECT IDENTIFIER of the Table, having as index numeric values. In this table, the value of agnStringToIndexUserName is an attribute.
Status: current Access: not-accessible
OBJECT-TYPE    
  OBJECT IDENTIFIER  

agnStringToIndexUserName 1.3.6.1.4.1.164.6.2.62.1.2
This object indicates a unique name used by agnStringToIndexTableId, although it is not it's index.
Status: current Access: not-accessible
OBJECT-TYPE    
  SnmpAdminString Size(1..64)  

agnStringToIndexTableIndex 1.3.6.1.4.1.164.6.2.62.1.3
The numeric Index of agnStringToIndexTableId.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

agnRowPointerTable 1.3.6.1.4.1.164.6.2.63
This table holds information about a specific entry in a table. For example, number of usages of this row.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnRowPointerEntry

agnRowPointerEntry 1.3.6.1.4.1.164.6.2.63.1
An entry in the table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AgnRowPointerEntry  

agnRowPointerIndex 1.3.6.1.4.1.164.6.2.63.1.1
The OBJECT IDENTIFIER of an entry in a table.
Status: current Access: not-accessible
OBJECT-TYPE    
  OBJECT IDENTIFIER  

agnRowPointerNoOfUsages 1.3.6.1.4.1.164.6.2.63.1.2
The number of usages of specific entry in a table, which is pointed by agnRowPointerIndex.Usually, when the value of this counter is greater than 0,the entry cannot be removed.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

radTransport 1.3.6.1.4.1.164.6.4
OBJECT IDENTIFIER    

radTransportDomains 1.3.6.1.4.1.164.6.4.1
OBJECT IDENTIFIER    

radTransportDomainSnmpEfmOam 1.3.6.1.4.1.164.6.4.1.1
The SNMP over EFM OAM transport domain. The corresponding transport address is of type RadTransportAddressEfmOam for EFM OAM addresses (port).
Status: current Access: read-only
OBJECT-IDENTITY    

systemsEvents 1.3.6.1.4.1.164.6.1.0
The events for RAD products.
Status: current Access: read-only
OBJECT-IDENTITY    

tftpStatusChangeTrap 1.3.6.1.4.1.164.6.1.0.1
This trap is sent whenever the status of tftp changed.
Status: current Access: read-only
NOTIFICATION-TYPE    

agnStatusChangeTrap 1.3.6.1.4.1.164.6.1.0.2
This trap is sent whenever the state of the entity the agent is responsible for changed. TDM devices will send agnTestStatus variable to indicate the current test status.
Status: current Access: read-only
NOTIFICATION-TYPE    

prtStatusChangeTrap 1.3.6.1.4.1.164.6.1.0.3
This trap is sent whenever the state of a port changed. Attached, will be parameter/s that indicate the new port status. The attached variables will be specified in the specifications of the products supporting this trap.
Status: current Access: read-only
NOTIFICATION-TYPE    

swdlStatusResult 1.3.6.1.4.1.164.6.1.0.4
This notification is sent when Software Down Load is finished. The attached object indicates the File Name.
Status: current Access: read-only
NOTIFICATION-TYPE    

intSwdlSlotFileMismatch 1.3.6.1.4.1.164.6.1.0.5
This notification is sent when the card in the chosen slot doesn't match the chosen file. The attached object indicates the File Name.
Status: current Access: read-only
NOTIFICATION-TYPE    

agnCounterChange 1.3.6.1.4.1.164.6.1.0.6
This notification is sent when the value of a specific Counter is changed. Agent can send as attached object the updated Counter. For details about this Counter and attached object, see spec of the relevant application.
Status: current Access: read-only
NOTIFICATION-TYPE    

prtClkSrcChangeTrap 1.3.6.1.4.1.164.6.1.0.7
This trap is sent upon any port clock change.
Status: current Access: read-only
NOTIFICATION-TYPE    

moduleFailTrap 1.3.6.1.4.1.164.6.1.0.8
This trap is sent upon a module failure.
Status: current Access: read-only
NOTIFICATION-TYPE    

moduleInitFailTrap 1.3.6.1.4.1.164.6.1.0.9
This trap is sent upon a module initialization failure.
Status: current Access: read-only
NOTIFICATION-TYPE    

clkSrcChangeTrap 1.3.6.1.4.1.164.6.1.0.10
This trap is sent upon any change in Clock Source.
Status: current Access: read-only
NOTIFICATION-TYPE    

agnUploadDataTrap 1.3.6.1.4.1.164.6.1.0.11
This trap is sent upon an upload data session termination. For more details see product specification.
Status: current Access: read-only
NOTIFICATION-TYPE    

enrollmentTrap 1.3.6.1.4.1.164.6.1.0.12
This trap is a periodically trap, which sent to manager untill Agent get any response (Get or Set) from this manager.
Status: current Access: read-only
NOTIFICATION-TYPE    

agnPowerFailureTrap 1.3.6.1.4.1.164.6.1.0.13
This trap is sent upon power failure. It is applicable for the following devices: 1. Devices having one PS unit, which sense the failure in advance, and still have time to send this trap before it goes off. 2. Devices having 2 PS units and send this trap in order to notify a failure in one of the units.
Status: current Access: read-only
NOTIFICATION-TYPE    

agnFanFailureTrap 1.3.6.1.4.1.164.6.1.0.14
This trap is sent upon fan failure/recovery.
Status: current Access: read-only
NOTIFICATION-TYPE    

agnSystemParameterChangeTrap 1.3.6.1.4.1.164.6.1.0.15
This trap is sent upon any change of the systemParameter value.
Status: current Access: read-only
NOTIFICATION-TYPE    

agnConfigDBChecksumError 1.3.6.1.4.1.164.6.1.0.16
This trap indicates that the database currently stored in the non-volatile memory of the device is corrupted
Status: current Access: read-only
NOTIFICATION-TYPE    

agnAlarmBufferOverflow 1.3.6.1.4.1.164.6.1.0.17
This trap indicates that the quantity of alarm messages which have been written in the alarm buffer, since the last clear command, exceeds predefined threshold. (Buffer size) The new alarms are overwriting the oldest alarms (the first alarms written in the buffer). For LA-110,threshold value is 200 alarms.
Status: current Access: read-only
NOTIFICATION-TYPE    

agnAlarmBufferClear 1.3.6.1.4.1.164.6.1.0.18
This trap indicates that alarm buffer has been cleared.
Status: current Access: read-only
NOTIFICATION-TYPE    

agnParametersValueChanged 1.3.6.1.4.1.164.6.1.0.19
This trap indicates that due to software upgrade, some of the parameters are assigned new values
Status: current Access: read-only
NOTIFICATION-TYPE    

agnDriverSwMismatch 1.3.6.1.4.1.164.6.1.0.20
There is mismatch between the SW driver and the HW of the device uplink interface.
Status: current Access: read-only
NOTIFICATION-TYPE    

agnActualLowRate 1.3.6.1.4.1.164.6.1.0.21
The main link is synchronized at a rate lower than expected.
Status: current Access: read-only
NOTIFICATION-TYPE    

xModemFileTransferStatusTrap 1.3.6.1.4.1.164.6.1.0.22
This trap is sent in the following cases: - When an xModem File Transfer Session begins. In this case, the trapVal.1 string sent will be: 'Start'. - When an xModem File Transfer Session ends. In this case, the trapVal.1 string sent will be one of the following, according to the way the session ended : - 'End: OK' - 'End: Failed'
Status: current Access: read-only
NOTIFICATION-TYPE    

agnStationClkFailureTrap 1.3.6.1.4.1.164.6.1.0.23
This trap is sent upon Station Clock failure.
Status: current Access: read-only
NOTIFICATION-TYPE    

successfulLogin 1.3.6.1.4.1.164.6.1.0.24
This trap is sent when a user performed successful Login via Terminal/Telnet/Web. This trap is used when the device is located at End-User's premises while management is at Service Provider's premises.
Status: current Access: read-only
NOTIFICATION-TYPE    

failedLogin 1.3.6.1.4.1.164.6.1.0.25
This trap is sent when a user tried to Login via Terminal/Telnet/Web and failed. This trap is used when the device is located at End-User's premises while management is at Service Provider's premises.
Status: current Access: read-only
NOTIFICATION-TYPE    

modlChangeTrap 1.3.6.1.4.1.164.6.1.0.26
This trap is sent whenever a module is inserted or removed. The trap should include the new module type (e.g. modlParamType).
Status: current Access: read-only
NOTIFICATION-TYPE    

licenseUpdateTrap 1.3.6.1.4.1.164.6.1.0.27
This trap is sent whenever a license is successfully downloaded or whenever a license's demo duration is expired.
Status: current Access: read-only
NOTIFICATION-TYPE    

agnClkSrcStateChangeTrap 1.3.6.1.4.1.164.6.1.0.28
The trap is sent upon change in Recovery Clock State.
Status: current Access: read-only
NOTIFICATION-TYPE    

agnSelfTestResultChangeTrap 1.3.6.1.4.1.164.6.1.0.29
The trap is sent upon each change in the result of a Self State operation.
Status: current Access: read-only
NOTIFICATION-TYPE    

agnClkSrcFrequencyAlarmTrap 1.3.6.1.4.1.164.6.1.0.31
The trap is sent upon Recovered Clock Frequency alarm.
Status: current Access: read-only
NOTIFICATION-TYPE    

genBridge 1.3.6.1.4.1.164.4.1
OBJECT IDENTIFIER    

radBridgeAction 1.3.6.1.4.1.164.4.1.1
This variable enables the operator to perform one of the specified actions on the tables maintained by the network device. Send actions are not currently implemented. Not all actions can be performed on all bridges.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER reset(1), sendNetworkTab(2), deleteNetworkTab(3), sendRoutingTab(4), deleteRoutinTab(5), sendLanTab(6), deleteLanTab(7), deleteArpTab(8), sendArpTab(9), deleteRouteTab(10), sendRouteTab(11), deactivateAllMasks(12), saveAllActiveMasks(13), loadAndActivateAllMasksFromNVRAM(14), clearAllMasksFromNVRAM(15), defaultConfig(16), resetNVRAM(17), clearIPNVRAM(18), noOp(255)  

radBridgeInactiveArpTimeOut 1.3.6.1.4.1.164.4.1.2
This variable defines the maximum time period that can pass between ARP requests concerning an entry in the ARP table. After this time period, the entry is deleted from the table.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

radBridgeMaskTable 1.3.6.1.4.1.164.4.1.3
Mask tables enable definition of forwarding restrictions and control of message flow in the internetwork. Each entry in this table defines a mask statement consisting of up to three mask definitions and an action defined by radBridgeMaskOper. Different types of mask entries are supported, as defined by radBridgeMaskType.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RadBridgeMaskEntry

radBridgeMaskEntry 1.3.6.1.4.1.164.4.1.3.1
An entry in table radBridgeMaskTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  RadBridgeMaskEntry  

radBridgeMaskType 1.3.6.1.4.1.164.4.1.3.1.1
Defines the type of mask entry.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER tx(1), rx(2), compress(3), priority(4), loadSharing(5), facs(6), codConnect(7), codDisconnect(8)  

radBridgeMaskIfIndex 1.3.6.1.4.1.164.4.1.3.1.2
Specifies the if Index of the interface to which the mask is applied.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

radBridgeMaskNum 1.3.6.1.4.1.164.4.1.3.1.3
The Mask entry number, defined by its line number in the mask table.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

radBridgeMaskDest 1.3.6.1.4.1.164.4.1.3.1.4
Specifies the type of destination address carried by the frame to which the mask will be applied. Unassigned-condition deactivates the mask entry.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unassigned-cond(1), broadcast-msge(2), multicast-msge(3), all-msge(4), none(5)  

radBridgeMaskPat1 1.3.6.1.4.1.164.4.1.3.1.5
Describes the mask field which is either a 16 bit binary pattern, or four digit hexadecimal pattern.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

radBridgeMaskActiveBit1 1.3.6.1.4.1.164.4.1.3.1.6
Specifies the positions of the wild card characters (*) in the radBridgeMaskPat1 field.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

radBridgeMaskFrom1 1.3.6.1.4.1.164.4.1.3.1.7
Offset base of radBridgeMaskPat1 within the frame. Net can be in some cases the data start point.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER mac(1), llc(2), net(3)  

radBridgeMaskOffset1 1.3.6.1.4.1.164.4.1.3.1.8
Specifies the radBridgeMaskPat1 offset within the frame (in bytes) from the base defined in by radBridgeMaskForm1.The mask offset is an even decimal number in the range of 0 to 1518.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

radBridgeMaskCond1 1.3.6.1.4.1.164.4.1.3.1.9
Specifies the logical condition of the mask pattern: true - Condition is valid if at the position specified by radBridgeMaskOffset1 the packet contains data that matches the content of radBridgeMaskPat1. false - Condition is valid if at the position specified by radBridgeMaskOffset1 the packet contains data that does not match the content of radBridgeMaskPat1.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER false(1), true(2)  

radBridgeMaskPat2 1.3.6.1.4.1.164.4.1.3.1.10
Describes the mask field which is either a 16 bit binary pattern, or four digit hexadecimal pattern.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

radBridgeMaskActiveBit2 1.3.6.1.4.1.164.4.1.3.1.11
Specifies the positions of the wild card characters (*) in the radBridgeMaskPat2 field.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

radBridgeMaskFrom2 1.3.6.1.4.1.164.4.1.3.1.12
Offset base of radBridgeMaskPat2 within the frame. Net can be in some cases the data start point.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER mac(1), llc(2), net(3)  

radBridgeMaskOffset2 1.3.6.1.4.1.164.4.1.3.1.13
Specifies the radBridgeMaskPat2 offset within the frame (in bytes) from the base defined in by radBridgeMaskForm2.The mask offset is an even decimal number in the range of 0 to 1518.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

radBridgeMaskCond2 1.3.6.1.4.1.164.4.1.3.1.14
Specifies the logical condition of the mask pattern: true - Condition is valid if at the position specified by radBridgeMaskOffset2 the packet contains data that matches the content of radBridgeMaskPat2. false - Condition is valid if at the position specified by radBridgeMaskOffset2 the packet contains data that does not match the content of radBridgeMaskPat2.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER false(1), true(2)  

radBridgeMaskPat3 1.3.6.1.4.1.164.4.1.3.1.15
Describes the mask field which is either a 16 bit binary pattern, or four digit hexadecimal pattern.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

radBridgeMaskActiveBit3 1.3.6.1.4.1.164.4.1.3.1.16
Specifies the positions of the wild card characters (*) in the radBridgeMaskPat3 field.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

radBridgeMaskFrom3 1.3.6.1.4.1.164.4.1.3.1.17
Offset base of radBridgeMaskPat3 within the frame. Net can be in some cases the data start point.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER mac(1), llc(2), net(3)  

radBridgeMaskOffset3 1.3.6.1.4.1.164.4.1.3.1.18
Specifies the radBridgeMaskPat3 offset within the frame (in bytes) from the base defined in by radBridgeMaskForm3. The mask offset is an even decimal number in the range of 0 to 1518.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

radBridgeMaskCond3 1.3.6.1.4.1.164.4.1.3.1.19
Specifies the logical condition of the mask pattern: true - Condition is valid if at the position specified by radBridgeMaskOffset3 the packet contains data that matches the content of radBridgeMaskPat3 false - Condition is valid if at the position specified by radBridgeMaskOffset3 the packet contains data that does not match the content of radBridgeMaskPat3.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER false(1), true(2)  

radBridgeMaskOper 1.3.6.1.4.1.164.4.1.3.1.20
The type of action to be taken if the frame meets the conditions of the mask. noOp = disabled (mask remains on list, but is not active) delete = mask is removed from the list.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER block(1), forward(2), route(3), forward-route(4), high-priority(5), noOp(6), delete(7)  

radBridgeCOD 1.3.6.1.4.1.164.4.1.4
OBJECT IDENTIFIER    

radBridgeCODParamTable 1.3.6.1.4.1.164.4.1.4.1
The table of COD parameters
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RadBridgeCODEntry

radBridgeCODEntry 1.3.6.1.4.1.164.4.1.4.1.1
Each radBridgeCODEntry consists of the following parameters
Status: current Access: not-accessible
OBJECT-TYPE    
  RadBridgeCODEntry  

radBridgeCODIfIndex 1.3.6.1.4.1.164.4.1.4.1.1.1
The interface to which this COD entry is applicable.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

radBridgeCODManualConnect 1.3.6.1.4.1.164.4.1.4.1.1.2
The management station can start connection manually by setting this parameter
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER connect(1), disconnect(2)  

radBridgeCODMode 1.3.6.1.4.1.164.4.1.4.1.1.3
In answer mode only one incoming call may be accepted at a time. Other nodes attempting to access the local modem will receive a busy signal until the connection is terminated. (Answer mode has no difficulty supporting multiple remote connections to one local port, as blocking multiple incoming calls is just a modem function. Originate mode, on the other hand will only support a single local port to remote port connection). The disable parameter disables the COD utility for this interface. Choosing any other mode will enable the COD utility.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER answer(1), originate(2), disable(3), answerAndOriginate(4)  

radBridgeCODConnectDelay 1.3.6.1.4.1.164.4.1.4.1.1.4
The connect delay defines the minimum time period that the link must stay disconnected, between 2 succesive connections (in seconds).
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

radBridgeCODisConnectDelay 1.3.6.1.4.1.164.4.1.4.1.1.5
The disconnect delay defines the minimum time period the link must stay connected, between 2 succesive disconnections (in seconds).
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

radBridgeCODImplicitSwitch 1.3.6.1.4.1.164.4.1.4.1.1.6
The inplicit switch allows the user to ignore implicit triggers provided by the COD software.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

radBridgeCODNumAccess 1.3.6.1.4.1.164.4.1.4.1.1.7
The number of successful connections that have been established since the COD has been reset.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

radBridgeCODTotalConnecTime 1.3.6.1.4.1.164.4.1.4.1.1.8
The sum of all the connect time intervals since the COD was reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

radBridgeCODTimeTriggerTable 1.3.6.1.4.1.164.4.1.4.2
The table of COD parameters
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RadBridgeCODTimeTriggerEntry

radBridgeCODTimeTriggerEntry 1.3.6.1.4.1.164.4.1.4.2.1
Each radBridgeCODTimeTriggerEntry consists of the following parameters
Status: current Access: not-accessible
OBJECT-TYPE    
  RadBridgeCODTimeTriggerEntry  

radBridgeCODTimeIfIndex 1.3.6.1.4.1.164.4.1.4.2.1.1
The interface to which this COD Time Trigger entry is applicable.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

radBridgeCODDay 1.3.6.1.4.1.164.4.1.4.2.1.2
The day of the week in which the dial up connection operates.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER mon(1), tue(2), wed(3), thu(4), fri(5), sat(6), sun(7)  

radBridgeCODTimeTriggerNum 1.3.6.1.4.1.164.4.1.4.2.1.3
Every day of the week the user can configure 3 dial up connections.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..3  

radBridgeCODTimeTriggerFrom 1.3.6.1.4.1.164.4.1.4.2.1.4
Time to start Dial Up connection, in format hh:mm.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

radBridgeCODTimeTriggerTo 1.3.6.1.4.1.164.4.1.4.2.1.5
Time to terminate Dial Up connection, in format HH:MM.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

radBridgeCODTimeTriggerStatus 1.3.6.1.4.1.164.4.1.4.2.1.6
The status of a table entry.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

radBridgeCODTraffic 1.3.6.1.4.1.164.4.1.4.3
OBJECT IDENTIFIER    

radBridgeCODTrafficTable 1.3.6.1.4.1.164.4.1.4.3.1
The table of COD Traffic trigger
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RadBridgeCODTrafficEntry

radBridgeCODTrafficEntry 1.3.6.1.4.1.164.4.1.4.3.1.1
Each radBridgeCODTrafficEntry consists of the following parameters.
Status: current Access: not-accessible
OBJECT-TYPE    
  RadBridgeCODTrafficEntry  

radBridgeCODProtocolType 1.3.6.1.4.1.164.4.1.4.3.1.1.1
The Protocol Type of the Traffic Table
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER ip(1), ipx(2), other(3)  

radBridgeCODTrafficTriggerStatus 1.3.6.1.4.1.164.4.1.4.3.1.1.2
Command of Status of the Protocol Traffic Trigger
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

radBridgeCODRemoteIPAddr 1.3.6.1.4.1.164.4.1.4.3.2
This is the Remote IP Address
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

radBridgeCODIPMask 1.3.6.1.4.1.164.4.1.4.3.3
This is the Mask of the Remote IP Address
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

radBridgeCODTrafficTriggerProtType 1.3.6.1.4.1.164.4.1.4.3.4
Protocol Type for the User Defined Protocol Traffic Trigger (3).
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

radBridgeCODCondTable 1.3.6.1.4.1.164.4.1.4.4
The table of COD Condition parameters
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RadBridgeCODCondEntry

radBridgeCODCondEntry 1.3.6.1.4.1.164.4.1.4.4.1
Each radBridgeCODCondEntry consists of the following parameters
Status: current Access: not-accessible
OBJECT-TYPE    
  RadBridgeCODCondEntry  

radBridgeCODCondIfIndex 1.3.6.1.4.1.164.4.1.4.4.1.1
The interface, this COD entry is applicable to.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

radBridgeCODOriginateConnectCondition 1.3.6.1.4.1.164.4.1.4.4.1.2
This condition, allows the user to specify the condition under which the link is connected. The options are onPowerOn - On power on. whenAnyStationOnLan - When any station on lan. onTraffic - On traffic. The user can specify the condition/s for connection. The connection will be defined in CODSpecificOnTrafficConditionOID . onManualConnect - depends on radBridgeCODManualConnect OBJECT-TYPE (=connect).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER onPowerOn(1), whenAnyStationOnLan(2), onTraffic(3), onManualConnect(4)  

radBridgeCODOriginateDisConnectCondition 1.3.6.1.4.1.164.4.1.4.4.1.3
This condition allows the user to specify the condition under which the link is disconnected. The options are: noStationOnLan - When there is no station on lan. Counts 15 minutes from the point the last frame from lan has been received. If no frame have been transmitted on lan by the end of this period, disconnect the connection. onTraffic - On traffic. The user can specify the condition/s for disconnection. The disconnection will be defined in CODSpecificOnTrafficConditionOID . onDelayFromConnectionOnRequest - On Delay From Connection On Request . The delay time period will be defined in CODOriginateDisConnectDelay . onManualDisConnect - depends on radBridgeCODManualConnect OBJECT-TYPE (=disconnect).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noStationOnLan(1), onTraffic(2), onDelayFromConnectionOnRequest(3), onManualDisConnect(4)  

radBridgeCODOriginateDisConnectDelay 1.3.6.1.4.1.164.4.1.4.4.1.4
Delay time in seconds.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

radBridgeCODAnswerConnectCondition 1.3.6.1.4.1.164.4.1.4.4.1.5
CODCondAnswerConnect allows the user to specify the condition under which the link is connected. The options are: onPowerOn - On power on. whenAnyStationOnLan - When any station on lan. onTraffic - On traffic. The user can specify the condition/s for connection. The connection will be defined in CODSpecificOnTrafficConditionOID . onManualConnect - depends on radBridgeCODManualConnect OBJECT-TYPE .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER onPowerOn(1), whenAnyStationOnLan(2), onTraffic(3), onManualConnect(4)  

radBridgeCODSpecificOnTrafficOIDCondition 1.3.6.1.4.1.164.4.1.4.4.1.6
A reference to a specific entry in the radBridgeMaskTable, which describes the particular COD condition . If Connect or Disconnect Conditions are not onTraffic, its value should be set to the OBJECT IDENTIFIER { 0 0 }.
Status: current Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

radBridgeCODDisConnectMinimunFramesNumber 1.3.6.1.4.1.164.4.1.4.4.1.7
Frames rate.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

radBridgeIPX 1.3.6.1.4.1.164.4.1.5
OBJECT IDENTIFIER    

radBridgeIPXdriver 1.3.6.1.4.1.164.4.1.5.1
OBJECT IDENTIFIER    

radBridgeIPXRip 1.3.6.1.4.1.164.4.1.5.2
OBJECT IDENTIFIER    

radBridgeIPXSap 1.3.6.1.4.1.164.4.1.5.3
OBJECT IDENTIFIER    

radBridgeIPXForwarding 1.3.6.1.4.1.164.4.1.5.1.1
The indication of whether this entity is acting as an IPX gateway in respect to the forwarding of datagrams received by, but not addressed to, this entity. IPX gateways forward datagrams. IPX hosts do not. Note that changing this parameter requiers RESET of the router.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER forwarding(1), not-forwarding(2)  

radBridgeIPXRipOutPackets 1.3.6.1.4.1.164.4.1.5.2.1
The total number of packets transmitted by RIP.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

radBridgeIPXRipInPackets 1.3.6.1.4.1.164.4.1.5.2.2
The total number of packets received by RIP. This will include any packets that are subsequently discarded.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

radBridgeIPXRipInDiscards 1.3.6.1.4.1.164.4.1.5.2.3
The number of received packets discarded by RIP.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

radBridgeIPXRipTblNoOfEntries 1.3.6.1.4.1.164.4.1.5.2.4
The max number of entries that exist in the RIP routing table.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

radBridgeIPXRipTblBcastTrigUpdateInterval 1.3.6.1.4.1.164.4.1.5.2.5
The default time interval (in seconds)between triggered RIP updates on a broadcast type interface. A triggered update occurs when a change is detected in the routing database. This time interval delays the broadcasting of these updates so that changes on the network will not result in a lot of triggered updates.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

radBridgeIPXRipTable 1.3.6.1.4.1.164.4.1.5.2.6
The routing table used by RIP to calculate routes to remote desination networks.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RadBridgeIPXRipTableEntry

radBridgeIPXRipTableEntry 1.3.6.1.4.1.164.4.1.5.2.6.1
The routing information for one of this entity's destination networks.
Status: current Access: not-accessible
OBJECT-TYPE    
  RadBridgeIPXRipTableEntry  

radBridgeIPXRipDestNetwork 1.3.6.1.4.1.164.4.1.5.2.6.1.1
The destination network address to which this entry's routing information pertains.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(4)  

radBridgeIPXRipPolicy 1.3.6.1.4.1.164.4.1.5.2.6.1.2
A value specifying the precidence of the route. A value of zero means that the route is the best route, a value of one means that the route is the second best route and so on.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER main(1), alternate(2)  

radBridgeIPXRipForwardingRouter 1.3.6.1.4.1.164.4.1.5.2.6.1.3
The IPX node address of the next hop (router) for the entry's associated destination network.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(6)  

radBridgeIPXRipNIC 1.3.6.1.4.1.164.4.1.5.2.6.1.4
An interface identifier specifying what IPX interface the next hop can be found on.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

radBridgeIPXRipTickMetric 1.3.6.1.4.1.164.4.1.5.2.6.1.5
The metric, in terms of transit time, associated with the route given by the entry. This time is in terms of 1/18ths of a second.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

radBridgeIPXRipHopMetric 1.3.6.1.4.1.164.4.1.5.2.6.1.6
The metric, in terms of distance , associated with the route given by the entry.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

radBridgeIPXRipAgingTime 1.3.6.1.4.1.164.4.1.5.2.6.1.7
The last time that the entry was updated. The time will be provided in terms of the MIB-I object sysUpTime.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

radBridgeIPXRipValueStatus 1.3.6.1.4.1.164.4.1.5.2.6.1.8
The entry status value; whether the entry is permanent (added statically), reachable or unreachable. In the latter two cases it would be added by RIP. A semiDynamic entry is an entry enterd manualy by the user and can be updated by the router.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER static(1), dynamic(2), invalid(3), semiDynamic(4)  

radBridgeIPXRipForwardType 1.3.6.1.4.1.164.4.1.5.2.6.1.9
The type of route. Note that local(2) refers to a route for which the next hop is the final destination; remote(3) refers to a route for which the next hop is not the final destination.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER other(1), local(2), remote(3)  

radBridgeIPXRipInfTable 1.3.6.1.4.1.164.4.1.5.2.7
The RIP interface table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RadBridgeIPXRipInfEntry

radBridgeIPXRipInfEntry 1.3.6.1.4.1.164.4.1.5.2.7.1
Each entry corresponds to one ifindex.
Status: current Access: not-accessible
OBJECT-TYPE    
  RadBridgeIPXRipInfEntry  

radBridgeIPXRipInfIfIndex 1.3.6.1.4.1.164.4.1.5.2.7.1.1
This value of Ifindex is same as radBridgeIPXIfIndex in the IPX Interface Table.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

radBridgeIPXRipInfBcastUpdate 1.3.6.1.4.1.164.4.1.5.2.7.1.2
The RIP periodic update interval, in seconds. Zero value corresponds to infinite interval.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

radBridgeIPXRipInfAgeMultiplier 1.3.6.1.4.1.164.4.1.5.2.7.1.3
The holding multiplier for information received in RIP periodic updates. Zero value corresponds to infinite aging time.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

radBridgeIPXSapOutPackets 1.3.6.1.4.1.164.4.1.5.3.1
The total number of packets transmitted by SAP.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

radBridgeIPXSapInPackets 1.3.6.1.4.1.164.4.1.5.3.2
The total number of packets received by SAP. This will include any packets that are subsequently discarded.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

radBridgeIPXSapInDiscards 1.3.6.1.4.1.164.4.1.5.3.3
The number of received packets discarded by SAP.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

radBridgeIPXSapTblNoOfEntries 1.3.6.1.4.1.164.4.1.5.3.4
The max number of entries that exist in the SAP Server Information table.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

radBridgeIPXSapTblBcastTrigUpdateInterval 1.3.6.1.4.1.164.4.1.5.3.5
The default time interval (in seconds) between triggered SAP updates on a broadcast style interface. A triggered update occurs when a change is detected in the service database. This time interval delays the transmission of these updates so that changes on the network will not result in a lot of triggered updates.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

radBridgeIPXSapTable 1.3.6.1.4.1.164.4.1.5.3.6
The Server Information table is used by SAP to store information of services which are available on the internetwork.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RadBridgeIPXSapTableEntry

radBridgeIPXSapTableEntry 1.3.6.1.4.1.164.4.1.5.3.6.1
The server information for one of this entity's server entries.
Status: current Access: not-accessible
OBJECT-TYPE    
  RadBridgeIPXSapTableEntry  

radBridgeIPXSapServerType 1.3.6.1.4.1.164.4.1.5.3.6.1.1
The type of the server for which this entry pertains.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

radBridgeIPXSapName 1.3.6.1.4.1.164.4.1.5.3.6.1.2
The name of the server for which this entry pertains.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(48)  

radBridgeIPXSapNetwork 1.3.6.1.4.1.164.4.1.5.3.6.1.3
The IPX network address of the host on which this server exists.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

radBridgeIPXSapNode 1.3.6.1.4.1.164.4.1.5.3.6.1.4
The IPX node address of the host on which this server exists.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(6)  

radBridgeIPXSapSocket 1.3.6.1.4.1.164.4.1.5.3.6.1.5
The IPX socket number that is being used by the server to which this entry pertains.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

radBridgeIPXSapHopsToServer 1.3.6.1.4.1.164.4.1.5.3.6.1.6
The number of hops to the entity on which this server exists.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..16  

radBridgeIPXSapNIC 1.3.6.1.4.1.164.4.1.5.3.6.1.7
An Network Interface Card identifier specifying what IPX interface the next hop can be found on.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

radBridgeIPXSapAgingTime 1.3.6.1.4.1.164.4.1.5.3.6.1.8
The last time that the entry was updated. The time will be provided in terms of the MIB-I object sysUpTime.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

radBridgeIPXSapStatus 1.3.6.1.4.1.164.4.1.5.3.6.1.9
The status of the entry.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER permanent(1), dynamic(2), invalid(3), semiDynamic(4)  

radBridgeIPXSapInfTable 1.3.6.1.4.1.164.4.1.5.3.7
The Sap interface table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RadBridgeIPXSapInfEntry

radBridgeIPXSapInfEntry 1.3.6.1.4.1.164.4.1.5.3.7.1
Each entry corresponds to one ifindex.
Status: current Access: not-accessible
OBJECT-TYPE    
  RadBridgeIPXSapInfEntry  

radBridgeIPXSapInfIfIndex 1.3.6.1.4.1.164.4.1.5.3.7.1.1
This value of Ifindex is same as radBridgeIPXIfIndex in the IPX Interface Table.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

radBridgeIPXSapInfBcastUpdate 1.3.6.1.4.1.164.4.1.5.3.7.1.2
The SAP periodic update interval, in seconds. Zero value corresponds to infinite interval.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

radBridgeIPXSapInfAgeMultiplier 1.3.6.1.4.1.164.4.1.5.3.7.1.3
The holding multiplier for information received in SAP periodic updates. Zero value corresponds to infinite aging time.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

newMasking 1.3.6.1.4.1.164.4.1.6
OBJECT IDENTIFIER    

maskingMaxEntries 1.3.6.1.4.1.164.4.1.6.1
The maximum number of entries in the masking table.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

maskingCurrentEntries 1.3.6.1.4.1.164.4.1.6.2
The number of entries in the mask table.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

maskingTable 1.3.6.1.4.1.164.4.1.6.3
This is the new masking scheme. Mask tables enable definition of forwarding restrictions and control of message flow in the internetwork. Each entry in this table defines a mask statement and an action defined by maskingOperation.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MaskingEntry

maskingEntry 1.3.6.1.4.1.164.4.1.6.3.1
Defines the contents of each line in the mask table.
Status: current Access: not-accessible
OBJECT-TYPE    
  MaskingEntry  

maskingType 1.3.6.1.4.1.164.4.1.6.3.1.1
Defines the type of mask entry.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER tx(1), rx(2), compress(3), priority(4), loadSharing(5), facs(6), codConnect(7), codDisconnect(8)  

maskingIfIndex 1.3.6.1.4.1.164.4.1.6.3.1.2
Specifies the ifIndex of the interface to which the mask is applied.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

maskingIndex 1.3.6.1.4.1.164.4.1.6.3.1.3
An index to the masking table. This number should not be greater than maskingMaxEntries
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

maskingProtocolType 1.3.6.1.4.1.164.4.1.6.3.1.4
The base protocol for masking. IPX, IP, others.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), ip(2), ipx(3), sna(4), netbios(5), apple(6), dec(7), all(255)  

maskingSmartMaskOID 1.3.6.1.4.1.164.4.1.6.3.1.5
A reference to a specific Smart mask table (old radBridgeMaskTable) which enables a more specific mask type. If this information is not available, its value should be set to the OBJECT IDENTIFIER { 0 0 }.
Status: current Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

maskingFrameType 1.3.6.1.4.1.164.4.1.6.3.1.6
Enables the user to decide about frame type * all frame * just broadcast * just multicast.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), all(2), broadcast(3), multicast(4)  

maskingFrameTypeCondition 1.3.6.1.4.1.164.4.1.6.3.1.7
Specifies the logical condition of the mask pattern: true - Condition is valid if at the position specified by maskingFrameType the packet contains data that matches the content of maskingFrameType. fa lse - Condition is valid if at the position specified by maskingFrameType the packet contains data that does not match the content of maskingFrameType.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER false(1), true(2)  

maskingSourceAddress 1.3.6.1.4.1.164.4.1.6.3.1.8
The source address is according to the maskingMacOrNet and maskingProtocolType variables. In case of 'MAC' enter 6 bytes (48 bit) of source address. In case of 'NET' if the maskingProtocolType is IP, this is the IP address if the maskingProtocolType is IPX, this is the IPX address (nnnnmmmmmmss) nnnn - IPX net address mmmmmm - Node address (Mac) ss - IPX socket In case of 'Apple' nn - net address (4 nibbles) ss - socket (4 nibbles).
Status: current Access: read-write
OBJECT-TYPE    
  GenAddress  

maskingSourceActiveBits 1.3.6.1.4.1.164.4.1.6.3.1.9
Specifies the positions of the wild card characters (*) in the maskingSourceAddress field. Only the 1's bit will be taken in considerations.
Status: current Access: read-write
OBJECT-TYPE    
  GenAddress  

maskingSourceMacOrNet 1.3.6.1.4.1.164.4.1.6.3.1.10
The variable maskingSourceAddress and maskingSourceActiveBits will be treated as MAC, or NET address. - If maskingProtocolType = 'all', 'sna', 'netbios', dec or 'unknown', the maskingSourceMacOrNet can be macAddress only! - If maskingProtocolType = 'ip' the maskingSourceMacOrNet can be macAddress or netAddress or appleAddress. - If maskingProtocolType = 'ipx', the maskingSourceMacOrNet can be either macAddress or netAddress. - If maskingProtocolType = 'apple', the maskingSourceMacOrNet can be either macAddress or appleAddress.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER macAddress(1), netAddress(2), ipRange(3), appleAddress(4)  

maskingSourceCondition 1.3.6.1.4.1.164.4.1.6.3.1.11
Specifies the logical condition of the mask pattern: true - Condition is valid if at the position specified by maskingSourceAddress (in conjunction with maskingSourceActiveBits) the packet contains data that matches the content of maskingSourceAddress. false - Condition is valid if at the position specified by maskingSourceAddress (in conjunction with maskingSourceActiveBits) the packet contains data that does not match the content of maskingSourceAddress.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER false(1), true(2)  

maskingDestAddress 1.3.6.1.4.1.164.4.1.6.3.1.12
If maskingFrameType = broadcast or multicast, this object is NOT APPLICABLE. If maskingFrameType = all or unknown, this object is applicable. The destination address is according to the maskingMacOrNet and maskingProtocolType variables. In case of 'MAC' enter 6 bytes (48 bit) of source address. In case of 'NET' if the maskingProtocolType is IP, this is the IP address if the maskingProtocolType is IPX, this is the IPX address (nnnnmmmmmmss) nnnn - IPX net address mmmmmm - Node address (Mac) ss - IPX socket. In case of 'Apple' nn - net address (4 nibbles) ss - socket (4 nibbles). The IPX socket entered here has priority over the value of maskingLowLevelProt, when it is ipxRip, ipxSap or ipxSpx, unless the entered IPX socket is don't care.
Status: current Access: read-write
OBJECT-TYPE    
  GenAddress  

maskingDestActiveBits 1.3.6.1.4.1.164.4.1.6.3.1.13
If maskingFrameType = broadcast or multicast, this object is NOT APPLICABLE. If maskingFrameType = all or unknown, this object is applicable. Specifies the positions of the wild card characters (*) in the maskingDestAddress field. Only the 1's bit will be taken in considerations.
Status: current Access: read-write
OBJECT-TYPE    
  GenAddress  

maskingDestMacOrNet 1.3.6.1.4.1.164.4.1.6.3.1.14
If maskingFrameType = broadcast or multicast, this object is NOT APPLICABLE. If maskingFrameType = all or unknown, this object is applicable. - If maskingProtocolType = 'all', 'sna', 'netbios', dec or 'unknown', the maskingDestMacOrNet can be macAddress only! - If maskingProtocolType = 'ip' the maskingDestMacOrNet can be macAddress or netAddress or appleAddress. - If maskingProtocolType = 'ipx', the maskingDestMacOrNet can be either macAddress or netAddress. - If maskingProtocolType = 'apple', the maskingDestMacOrNet can be either macAddress or appleAddress. The variable maskingDestAddress and maskingDestActiveBits will be treated as MAC, or NET address.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER macAddress(1), netAddress(2), ipRange(3), appleAddress(4)  

maskingDestCondition 1.3.6.1.4.1.164.4.1.6.3.1.15
If maskingFrameType = broadcast or multicast, this object is NOT APPLICABLE. If maskingFrameType = all or unknown, this object is applicable. Specifies the logical condition of the mask pattern: true - Condition is valid if at the position specified by maskingDestAddress (in conjunction with maskingDestActiveBits) the packet contains data that matches the content of maskingDestAddress. false - Condition is valid if at the position specified by maskingDestAddress (in conjunction with maskingDestActiveBits) the packet contains data that does not match the content of maskingDestAddress.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER false(1), true(2)  

maskingLowLevelProt 1.3.6.1.4.1.164.4.1.6.3.1.16
This field is set in conjunction with the maskingProtocolType variable. This variable specifies the low level protocol. The IPX socket entered in maskingDestAddress has priority over the value of maskingLowLevelProt, when it is ipxRip, ipxSap or ipxSpx, unless the entered IPX socket is don't care.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), ipxRip(2), ipxSap(3), ipxSpx(4), ipUdp(5), ipTcp(6), ipIcmp(7), ipxNcp(8), ipxWan(9), ipxEco(10), ipxErr(11), ipxPep(12)  

maskingLowLevelProtCondition 1.3.6.1.4.1.164.4.1.6.3.1.17
Specifies the logical condition of the mask pattern: true - Condition is valid if at the position specified by maskingLowLevelProt the packet contains data that matches the content of maskingLowLevelProt. false - Condition is valid if at the position specified by maskingLowLevelProt the packet contains data that does not match the content of maskingLowLevelProt.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER false(1), true(2)  

maskingHighLevelProt 1.3.6.1.4.1.164.4.1.6.3.1.18
This field is set in connection to the maskingProtocolType variable. This variable specifies the high level protocols (application). As for today it supports just IP protocol stack. The object's value is a sum of the following instances values (selected by user): none (0), -- don't care ftp (1), ftpC (2), telnet (4), smtp (8), tftp (16), snmp (32), snmpTrap (64), ipRip (128), www (256), email (512), dns (1024), For Apple Protocol only: rtmp (2048), nbp (4096), atp (8192), aep (16384), zip (32768), adsp (65536), pap (131072), asp (262144) Example: if ftp(1), snmp(32) and snmpTrap(64) instances were selected, the value should be 97 (=1+32+64).
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

maskingHighLevelProtCondition 1.3.6.1.4.1.164.4.1.6.3.1.19
Specifies the logical condition of the mask pattern: true - Condition is valid if at the position specified by maskingHighLevelProt the packet contains data that matches the content of maskingHighLevelProt. false - Condition is valid if at the position specified by maskingHighLevelProt the packet contains data that does not match the content of maskingHighLevelProt.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER false(1), true(2)  

maskingPortNum 1.3.6.1.4.1.164.4.1.6.3.1.20
The port number is the same as in high level protocol. It specifies the dest. port in IP case or the dest. socket in case of IPX & apple protocols. IP - This object is applicable only if none (0) value was selected in maskingHighLevelProt. IPX - This object is applicable only if the socket entered in maskingDestAddress is 'don't care'(00) AND maskingLowLevelProt is NOT ipxRip or ipxSap. Apple - This option is applicable only if the socket entered in maskingDestAddress is 'don't care'(00).
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

maskingPortNumCondition 1.3.6.1.4.1.164.4.1.6.3.1.21
Specifies the logical condition of the mask pattern: true - Condition is valid if at the position specified by maskingPortNum the packet contains data that matches the content of maskingPortNum. false - Condition is valid if at the position specified by maskingPortNum the packet contains data that does not match the content of maskingPortNum. This object is applicable only when maskingPortNum is applicable.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER false(1), true(2)  

maskingOperation 1.3.6.1.4.1.164.4.1.6.3.1.22
The type of action to be taken if the frame meets the conditions of the mask. noOp = disabled (mask remains on list, but is not active) delete = mask is removed from the list. smartMask = the operation and destination of the mask will be determined by the objects of the Smart Table (old masking table: radBridgeMaskTable). If maskingType is codConnect, the 'block' value is NOT allowed. If maskingType is codDisconnect, the 'forward' value is NOT allowed.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER block(1), forward(2), route(3), forward-route(4), high-priority(5), noOp(6), delete(7), smartMask(8)  

maskingSrcPortNum 1.3.6.1.4.1.164.4.1.6.3.1.23
The source port number. For IP: No Condition. For IPX: This object is applicable only if the socket entered in maskingSourceAddress is don't care (00) and maskingLowLevelProt is NOT ipxRip or ipxSap. For Apple:This object is applicable only if the socket entered in maskingSourceAddress is don't care (00).
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

maskingSrcPortNumCondition 1.3.6.1.4.1.164.4.1.6.3.1.24
The same as 'maskingPortNumCondition'. Relates to source port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER false(1), true(2)  

radBridgePerformance 1.3.6.1.4.1.164.4.1.7
OBJECT IDENTIFIER    

radBridgeCurrentTable 1.3.6.1.4.1.164.4.1.7.1
The RAD Bridge Current table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RadBridgeCurrentEntry

radBridgeCurrentEntry 1.3.6.1.4.1.164.4.1.7.1.1
An entry in the RAD Bridge Current table.
Status: current Access: not-accessible
OBJECT-TYPE    
  RadBridgeCurrentEntry  

radBridgeCurrentIndex 1.3.6.1.4.1.164.4.1.7.1.1.1
The index of the Bridge interface or Bridge Port. It may be ifIndex.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

radBridgeCurrentIngressFilteringDiscardedFrames 1.3.6.1.4.1.164.4.1.7.1.1.2
The counter associated with the number of Discarded Frames upon Ingress Filtering, encountered by a Bridge interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

radBridgeCurrentFrameTypeDiscardedFrames 1.3.6.1.4.1.164.4.1.7.1.1.3
The counter associated with the number of Discarded Frames upon Frame Type and Tagging Mismatch, encountered by a Bridge interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

radBridgeCurrentRxCorrectFrames 1.3.6.1.4.1.164.4.1.7.1.1.4
The counter associated with the number of Received Correct Frames, encountered by a Bridge Port in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

radBridgeCurrentRxCorrectBytes 1.3.6.1.4.1.164.4.1.7.1.1.5
The counter associated with the number of Received Correct Bytes, encountered by a Bridge Port in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

radBridgeCurrentRxCorrectBytesHCOverflow 1.3.6.1.4.1.164.4.1.7.1.1.6
The counter associated with the number of times the associated radBridgeCurrentRxCorrectBytes counter has overflowed.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

radBridgeCurrentRxBcastFrames 1.3.6.1.4.1.164.4.1.7.1.1.7
The counter associated with the number of Received Broadcast Frames, encountered by a Bridge Port in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

radBridgeCurrentRxMcastFrames 1.3.6.1.4.1.164.4.1.7.1.1.8
The counter associated with the number of Received Multicast Frames, encountered by a Bridge Port in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

radBridgeCurrentTxCorrectFrames 1.3.6.1.4.1.164.4.1.7.1.1.9
The counter associated with the number of Transmitted Correct Frames, encountered by a Bridge Port in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

radBridgeCurrentTxCorrectBytes 1.3.6.1.4.1.164.4.1.7.1.1.10
The counter associated with the number of Transmitted Correct Bytes, encountered by a Bridge Port in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

radBridgeCurrentTxCorrectBytesHCOverflow 1.3.6.1.4.1.164.4.1.7.1.1.11
The counter associated with the number of times the associated radBridgeCurrentTxCorrectBytes counter has overflowed.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

radBridgeCurrentTxBcastFrames 1.3.6.1.4.1.164.4.1.7.1.1.12
The counter associated with the number of Transmitted Broadcast Frames, encountered by a Bridge Port in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

radBridgeCurrentTxMcastFrames 1.3.6.1.4.1.164.4.1.7.1.1.13
The counter associated with the number of Transmitted Multicast Frames, encountered by a Bridge Port in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

radBridgeCurrentTxDropFrames 1.3.6.1.4.1.164.4.1.7.1.1.14
The counter associated with the number of Transmitted Dropped Frames, encountered by a Bridge Port in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

radBridgeIntervalTable 1.3.6.1.4.1.164.4.1.7.2
The RAD Bridge Interval table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RadBridgeIntervalEntry

radBridgeIntervalEntry 1.3.6.1.4.1.164.4.1.7.2.1
An entry in the RAD Bridge Interval table.
Status: current Access: not-accessible
OBJECT-TYPE    
  RadBridgeIntervalEntry  

radBridgeIntervalIndex 1.3.6.1.4.1.164.4.1.7.2.1.1
The index of the bridge interface or Bridge Port. It may be ifIndex.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

radBridgeIntervalNumber 1.3.6.1.4.1.164.4.1.7.2.1.2
A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals exist).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..96  

radBridgeIntervalIngressFilteringDiscardedFrames 1.3.6.1.4.1.164.4.1.7.2.1.3
The counter associated with the number of Discarded Frames upon Ingress Filtering, encountered by a Bridge interface in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

radBridgeIntervalFrameTypeDiscardedFrames 1.3.6.1.4.1.164.4.1.7.2.1.4
The counter associated with the number of Discarded Frames upon Frame Type and Tagging Mismatch, encountered by a Bridge interface in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

radBridgeIntervalRxCorrectFrames 1.3.6.1.4.1.164.4.1.7.2.1.5
The counter associated with the number of Received Correct Frames, encountered by a Bridge Port in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

radBridgeIntervalRxCorrectBytes 1.3.6.1.4.1.164.4.1.7.2.1.6
The counter associated with the number of Received Correct Bytes, encountered by a Bridge Port in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

radBridgeIntervalRxCorrectBytesHCOverflow 1.3.6.1.4.1.164.4.1.7.2.1.7
The counter associated with the number of times the associated radBridgeIntervalRxCorrectBytes counter has overflowed.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

radBridgeIntervalRxBcastFrames 1.3.6.1.4.1.164.4.1.7.2.1.8
The counter associated with the number of Received Broadcast Frames, encountered by a Bridge Port in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

radBridgeIntervalRxMcastFrames 1.3.6.1.4.1.164.4.1.7.2.1.9
The counter associated with the number of Received Multicast Frames, encountered by a Bridge Port in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

radBridgeIntervalTxCorrectFrames 1.3.6.1.4.1.164.4.1.7.2.1.10
The counter associated with the number of Transmitted Correct Frames, encountered by a Bridge Port in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

radBridgeIntervalTxCorrectBytes 1.3.6.1.4.1.164.4.1.7.2.1.11
The counter associated with the number of Transmitted Correct Bytes, encountered by a Bridge Port in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

radBridgeIntervalTxCorrectBytesHCOverflow 1.3.6.1.4.1.164.4.1.7.2.1.12
The counter associated with the number of times the associated radBridgeIntervalTxCorrectBytes counter has overflowed.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

radBridgeIntervalTxBcastFrames 1.3.6.1.4.1.164.4.1.7.2.1.13
The counter associated with the number of Transmitted Broadcast Frames, encountered by a Bridge Port in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

radBridgeIntervalTxMcastFrames 1.3.6.1.4.1.164.4.1.7.2.1.14
The counter associated with the number of Transmitted Multicast Frames, encountered by a Bridge Port in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

radBridgeIntervalTxDropFrames 1.3.6.1.4.1.164.4.1.7.2.1.15
The counter associated with the number of Transmitted Dropped Frames, encountered by a Bridge Port in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

radBridgePortBaseVlan 1.3.6.1.4.1.164.4.1.8
OBJECT IDENTIFIER    

radBridgePortBaseVlanTable 1.3.6.1.4.1.164.4.1.8.1
A table containing static configuration information for each VLAN configured into the device by management. All entries are permanent and will be restored after the device is reset.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RadBridgePortBaseVlanEntry

radBridgePortBaseVlanEntry 1.3.6.1.4.1.164.4.1.8.1.1
Static information for a VLAN configured into the device by (local or network) management.
Status: current Access: not-accessible
OBJECT-TYPE    
  RadBridgePortBaseVlanEntry  

radBridgePortBaseVlanCnfgIdx 1.3.6.1.4.1.164.4.1.8.1.1.1
This object indicates the Idx of the Agent Cnfg the following objects refer. 255=Temporary Cnfg (when relevant, Set is done only to this configuration). For Agents that support only one configuration, this object will be constant=1.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..255  

radBridgePortBaseVlanIdx 1.3.6.1.4.1.164.4.1.8.1.1.2
Index of the port based VLAN.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

radBridgePortBaseVlanName 1.3.6.1.4.1.164.4.1.8.1.1.3
An administratively assigned string, which may be used to identify the the port based VLAN.
Status: current Access: read-create
OBJECT-TYPE    
  SnmpAdminString Size(0..32)  

radBridgePortBaseVlanEgressPorts 1.3.6.1.4.1.164.4.1.8.1.1.4
The set of ports which are permanently assigned to the egress list for this port based VLAN by management. The default value of this object is a string of zeros.
Status: current Access: read-create
OBJECT-TYPE    
  PortList  

radBridgePortBaseVlanVirtualGroups 1.3.6.1.4.1.164.4.1.8.1.1.5
The set of Virtual Groups which are permanently assigned to this port based VLAN by management. (read Virtual Group instead of port in PortList Textual Convention) The default value of this object is a string of zeros.
Status: current Access: read-create
OBJECT-TYPE    
  PortList  

radBridgePortBaseVlanRowStatus 1.3.6.1.4.1.164.4.1.8.1.1.6
This object enable user to create/delete entries in this table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

radBridgePortBaseVlanMng 1.3.6.1.4.1.164.4.1.8.1.1.7
This object allows user to enable/disable management traffic on this VLAN. disable - only non-management data is allowed. enable - mixture of management traffic 0with other types of data is allowed.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

radBridgePortVlanMemberTable 1.3.6.1.4.1.164.4.1.8.2
The Bridge Ports-VLAN Membership table. This table enables the user to assign: - Several VLANs to a Port. - Several Ports to a VLAN.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RadBridgePortVlanMemberEntry

radBridgePortVlanMemberEntry 1.3.6.1.4.1.164.4.1.8.2.1
An entry in the Bridge Ports-VLANs Memebership table.
Status: current Access: not-accessible
OBJECT-TYPE    
  RadBridgePortVlanMemberEntry  

radBridgePortVlanMemberBridgeIdx 1.3.6.1.4.1.164.4.1.8.2.1.1
This object indicates the Bridge Index.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

radBridgePortVlanMemberPortIdx 1.3.6.1.4.1.164.4.1.8.2.1.2
This object indicates the Bridge's Port Index. For some cases, it can be used as the Port ofIndex.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

radBridgePortVlanMemberVlanId 1.3.6.1.4.1.164.4.1.8.2.1.3
This object indicates the VLAN ID.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

radBridgePortVlanMemberRowStatus 1.3.6.1.4.1.164.4.1.8.2.1.4
This object enables the user to create/delete entries in this table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

radBridgeGenCnfg 1.3.6.1.4.1.164.4.1.9
OBJECT IDENTIFIER    

radBridgeGenFlowTable 1.3.6.1.4.1.164.4.1.9.1
A table containing static configuration information for Bridge configured into the device by (local or network) management. All entries are permanent and will be restored after the device is reset.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RadBridgeGenFlowEntry

radBridgeGenFlowEntry 1.3.6.1.4.1.164.4.1.9.1.1
Static information for a Bridge configured into the device by management.
Status: current Access: not-accessible
OBJECT-TYPE    
  RadBridgeGenFlowEntry  

radBridgeGenFlowCnfgIdx 1.3.6.1.4.1.164.4.1.9.1.1.1
This object indicates the Idx of the Agent Cnfg the following objects refer. 255=Temporary Cnfg (when relevant Set is done only to this configuration). For Agents that support only one configuration, this object will be constant=1. This object can be used to carry additional indexing (e.g port index) when needed.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..2147483647  

radBridgeGenFlowIdx 1.3.6.1.4.1.164.4.1.9.1.1.2
For Agent having more than one bridge, this index may be used as bridge index
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

radBridgeGenFlowRowStatus 1.3.6.1.4.1.164.4.1.9.1.1.3
This object enable user to create/delete entries in this table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

radBridgeGenFlowFloodOrBcastMaxRate 1.3.6.1.4.1.164.4.1.9.1.1.4
This object controls maximum Flooding or Broadcast Rate: Max number of multicast along with unknown or flooded unicast frames allowed to enter any port. The number can be presented either as percentage of bandwidth, or bandwidth in Kbps. Once the limit is exceeded, any multicast or flooded frame entering from the port is discarded For RIC-155, and FCD-155 valid values are 3% , 6%, 12% and 100% = No Limit
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

radBridgeGenFlowQosMode 1.3.6.1.4.1.164.4.1.9.1.1.5
This object controls Quality of Service mode. User may select which field(s) (in case of fields - which one has precedence) will affect prioritization of data between egress queues.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER notApplicable(1), vlanTag(2), dscp(3), dscpAndVlanTag(4), vlanTagAndDscp(5), none(6), tos(7), perPort(8), ipPrecedence(9), dsField(10), vlanTagAndTos(11), tosAndVlanTag(12), vlanTagAndIpPrecedence(13), ipPrecedenceAndVlanTag(14), vlanTagAndDsField(15), dsFieldAndVlanTag(16)  

radBridgeGenFlowSchedulingMode 1.3.6.1.4.1.164.4.1.9.1.1.6
This object controls which scheduling mode is used: Weighted Fair Queuing (WFQ) scheme, Strict Priority (SP) or ATM CoS
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER notApplicable(1), wfq(2), sp(3), atmCos(4)  

radBridgeGenFlowBasicClassification 1.3.6.1.4.1.164.4.1.9.1.1.7
This object defines whether Classification based on Port should be taken into account (either as default, or in addition to other classifications).
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER none(2), port(3)  

radBridgeGenFlowMulticastTrafficClass 1.3.6.1.4.1.164.4.1.9.1.1.8
The Traffic Class the received Multicast frame is mapped to.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

radBridgeGenFlowBroadcastTrafficClass 1.3.6.1.4.1.164.4.1.9.1.1.9
The Traffic Class the received Broadcast frame is mapped to.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

radBridgeGenFlowUnkownUnicastTrafficClass 1.3.6.1.4.1.164.4.1.9.1.1.10
The Traffic Class the received Unkonwn Unicast frame is mapped to.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

radBridgeDot1qVlanStaticTable 1.3.6.1.4.1.164.4.1.9.2
A table containing static configuration information for each VLAN configured into the device by (local or network) management. All entries are permanent and will be restored after the device is reset.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RadBridgeDot1qVlanStaticEntry

radBridgeDot1qVlanStaticEntry 1.3.6.1.4.1.164.4.1.9.2.1
Static information for a VLAN configured into the device by (local or network) management.
Status: current Access: not-accessible
OBJECT-TYPE    
  RadBridgeDot1qVlanStaticEntry  

radBridgeDot1qVlanTaggedPorts 1.3.6.1.4.1.164.4.1.9.2.1.1
The set of ports which should transmit egress packets for this VLAN as tagged.
Status: current Access: read-create
OBJECT-TYPE    
  PortList  

radBridgeDot1qVlanUnmodifiedPorts 1.3.6.1.4.1.164.4.1.9.2.1.2
The set of ports which should transmit egress packets for this VLAN as unmodified.
Status: current Access: read-create
OBJECT-TYPE    
  PortList  

radBridgeDot1qVlanSplitHorizon 1.3.6.1.4.1.164.4.1.9.2.1.3
When 'enable (3)', packets having this VLAN will not be switched back to other bridge ports which are members of this VLAN.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

radBridgeStatus 1.3.6.1.4.1.164.4.1.10
OBJECT IDENTIFIER    

radBridgeInvBasePortTable 1.3.6.1.4.1.164.4.1.10.1
An inversed table to dot1dBasePortTable from RFC1493 with reduced information. This table index is known to the NMS and this way the needed information can be received by just one Get command, instead of searching the entire dot1dBasePortTable (where it is an attribute).
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RadBridgeInvBasePortEntry

radBridgeInvBasePortEntry 1.3.6.1.4.1.164.4.1.10.1.1
The bridge port number for each bridge port interface index.
Status: current Access: not-accessible
OBJECT-TYPE    
  RadBridgeInvBasePortEntry  

radBridgeInvBasePortIfIndex 1.3.6.1.4.1.164.4.1.10.1.1.1
The value of the instance of the ifIndex object, defined in MIB-II, for the interface corresponding to this Bridge port.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

radBridgeInvBasePort 1.3.6.1.4.1.164.4.1.10.1.1.2
The Bridge port number.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

radBridgeStp 1.3.6.1.4.1.164.4.1.11
OBJECT IDENTIFIER    

radBridgeStpCnfgTable 1.3.6.1.4.1.164.4.1.11.1
STP Configuration table. STP=Spanning Tree Protocol. It includes STP configurable parameters that in BRIDGE-MIB are scalars, while we need them per card/bridge/interface and per different configurations.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RadBridgeStpCnfgEntry

radBridgeStpCnfgEntry 1.3.6.1.4.1.164.4.1.11.1.1
An entry in the radBridgeStpCnfgTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  RadBridgeStpCnfgEntry  

radBridgeStpCnfgIdx1 1.3.6.1.4.1.164.4.1.11.1.1.1
This object indicates the Index of the Agent Configuration the following objects refer to. For Agents that support more than one configuration: 255=Temporary Cnfg ; Set can be done only to this configuration. For Agents that support only one configuration, this object will be constant=1.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..255  

radBridgeStpCnfgIdx2 1.3.6.1.4.1.164.4.1.11.1.1.2
For Agents having the table objects per Card/Bridge/Interface this will be the index of the Card/Bridge/Interface used.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

radBridgeStpCnfgForwardDelay 1.3.6.1.4.1.164.4.1.11.1.1.3
The value that the bridge of radBridgeStpCnfgIdx2 uses for Forward Delay when this bridge is acting as the root. Note that the range for this parameter is related to the value of radBridgeStpCnfgMaxAge (according to 802.1D-1990 for the similar scalars of BRIDGE-MIB). The granularity of this timer is specified by 802.1D-1990 to be 1 second. An agent may return a badValue error if a set is attempted to a value which is not a whole number of seconds.
Status: current Access: read-write
OBJECT-TYPE    
  Timeout 400..3000  

radBridgeStpCnfgMaxAge 1.3.6.1.4.1.164.4.1.11.1.1.4
The value that the bridge of radBridgeStpCnfgIdx2 uses for MaxAge when this bridge is acting as the root. Note that the range for this parameter is related to the value of radBridgeStpCnfgHelloTime (according to 802.1D-1990 for the similar scalars of BRIDGE-MIB). The granularity of this timer is specified by 802.1D-1990 to be 1 second. An agent may return a badValue error if a set is attempted to a value which is not a whole number of seconds.
Status: current Access: read-write
OBJECT-TYPE    
  Timeout 600..4000  

radBridgeStpCnfgHelloTime 1.3.6.1.4.1.164.4.1.11.1.1.5
The value that the bridge of radBridgeStpCnfgIdx2 uses for Hello Time when this bridge is acting as the root. The granularity of this timer is specified by 802.1D-1990 to be 1 second. An agent may return a badValue error if a set is attempted to a value which is not a whole number of seconds.
Status: current Access: read-write
OBJECT-TYPE    
  Timeout 100..1000  

radBridgeStpCnfgPriority 1.3.6.1.4.1.164.4.1.11.1.1.6
The value of the write-able portion of the Bridge ID, i.e., the first two octets of the (8 octet long) Bridge ID, per radBridgeStpCnfgIdx2 instance.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..65535  

radBridgeStpCnfgStpVersion 1.3.6.1.4.1.164.4.1.11.1.1.7
This object determines the STP version used: stp - usual Spanning Tree Protocol. rstp - Rapid Spanning Tree Protocol.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), stp(2), rstp(3)  

radBridgeStpStatTable 1.3.6.1.4.1.164.4.1.11.2
STP Status table. STP=Spanning Tree Protocol. It includes STP status parameters that in BRIDGE-MIB are scalars, while we need them per card/bridge/interface. For devices that have several configurations, this table is for Status of the Active configuration.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RadBridgeStpStatEntry

radBridgeStpStatEntry 1.3.6.1.4.1.164.4.1.11.2.1
An entry in the radBridgeStpStatTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  RadBridgeStpStatEntry  

radBridgeStpStatIdx 1.3.6.1.4.1.164.4.1.11.2.1.1
For Agents having the table objects per Card/Bridge/Interface this will be the index of the Card/Bridge/Interface used.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

radBridgeStpStatForwardDelay 1.3.6.1.4.1.164.4.1.11.2.1.2
This time value, measured in units of hundredths of a second, controls how fast a port changes its spanning state when moving towards the Forwarding state. The value determines how long the port stays in each of the Listening and Learning states, which precede the Forwarding state. This value is also used, when a topology change has been detected and is underway, to age all dynamic entries in the Forwarding Database. [Note that this value is the one that this bridge is currently using, in contrast to radBridgeStpCnfgForwardDelay which is the value that this bridge would start using if/when this bridge were to become the root.]
Status: current Access: read-only
OBJECT-TYPE    
  Timeout  

radBridgeStpStatMaxAge 1.3.6.1.4.1.164.4.1.11.2.1.3
The maximum age of Spanning Tree Protocol information learned from the network on any port before it is discarded, in units of hundredths of a second. This is the actual value that this bridge is currently using.
Status: current Access: read-only
OBJECT-TYPE    
  Timeout  

radBridgeStpStatHelloTime 1.3.6.1.4.1.164.4.1.11.2.1.4
The amount of time between the transmission of Configuration bridge PDUs by this node on any port when it is the root of the spanning tree or trying to become so, in units of hundredths of a second. This is the actual value that this bridge is currently using.
Status: current Access: read-only
OBJECT-TYPE    
  Timeout  

radBridgeStpStatDesignatedRoot 1.3.6.1.4.1.164.4.1.11.2.1.5
The bridge identifier of the root of the spanning tree as determined by the Spanning Tree Protocol as executed by this node. This value is used as the Root Identifier parameter in all Configuration Bridge PDUs originated by this node.
Status: current Access: read-only
OBJECT-TYPE    
  BridgeId  

radBridgeStpStatRootCost 1.3.6.1.4.1.164.4.1.11.2.1.6
The cost of the path to the root as seen from this bridge.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

radBridgeForwardingMode 1.3.6.1.4.1.164.4.1.12
This object determines the Bridge Forwarding Mode: transparent - Forward all frames received (not dependent on VLAN). filter - Filter frames received according to MAC Address. filterTagged = Filter frames received according to VLAN. transparentTagged = VLAN aware + Transparent.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), transparent(2), filter(3), filterTagged(4), transparentTagged(5)  

radBridgePort 1.3.6.1.4.1.164.4.1.13
OBJECT IDENTIFIER    

radBridgePortCnfgTable 1.3.6.1.4.1.164.4.1.13.1
The Bridge Port Configuration Table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RadBridgePortCnfgEntry

radBridgePortCnfgEntry 1.3.6.1.4.1.164.4.1.13.1.1
An entry in the table.
Status: current Access: not-accessible
OBJECT-TYPE    
  RadBridgePortCnfgEntry  

radBridgePortCnfgIdx 1.3.6.1.4.1.164.4.1.13.1.1.1
The first index of the table. It can serve for Configuration index, Bridge index or other.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

radBridgePortCnfgPrtIdx 1.3.6.1.4.1.164.4.1.13.1.1.2
This object indicates the Bridge Port index.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

radBridgePortCnfgMaxMacAddr 1.3.6.1.4.1.164.4.1.13.1.1.3
This object indicates the maximum number of total MAC Addresses (static and learned) supported by this Bridge Port.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

radBridgePortCnfgMngFlow 1.3.6.1.4.1.164.4.1.13.1.1.4
This object indicates whether this Bridge Port is dedicated for management flow.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(2), enable(3)  

radBridgePortCnfgMcastMode 1.3.6.1.4.1.164.4.1.13.1.1.5
This object indicates this Bridge Port's Multicast Mode: flooding (1) - flood multicast MAC addresses forwarding (2) - forward multicast MAC addresses to the subnet indicated.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER flooding(1), forwarding(2)  

radBridgePortCnfgDefaultVpi 1.3.6.1.4.1.164.4.1.13.1.1.6
This object indicates the VPI of this Bridge Port's Default VCL. An incoming frame with priority that is not assigned to any VCL will be transferred to the Default VCL.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

radBridgePortCnfgDefaultVci 1.3.6.1.4.1.164.4.1.13.1.1.7
This object indicates the VCI of this Bridge Port's Default VCL. An incoming frame with priority that is not assigned to any VCL will be transferred to the Default VCL.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

radBridgePortCnfgStatVlanId 1.3.6.1.4.1.164.4.1.13.1.1.8
This object indicates the selected VlanId of the bridge port on which statistics are being collected. 0=no Statistics collected for VLAN on this bridge port.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

radBridgePortCnfgIngressMtu 1.3.6.1.4.1.164.4.1.13.1.1.9
The size of the largest packet which can be received on the interface, specified in octets.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

radBridgePortCnfgEgressMtu 1.3.6.1.4.1.164.4.1.13.1.1.10
The size of the largest packet which can be sent on the interface, specified in octets.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

radBridgePortCnfgDot1x 1.3.6.1.4.1.164.4.1.13.1.1.11
This feature is currently supported via the variable ethIfTable.ethDot1xEnable. Determnines if the Port-Based Network Access Protocol (IEEE-802.1x)is enabled for the bridge Port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(2), enabled(3)  

radDot1qPortVlanTable 1.3.6.1.4.1.164.4.1.9.3
A table containing control and status information for VLAN configuration per port.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RadDot1qPortVlanEntry

radDot1qPortVlanEntry 1.3.6.1.4.1.164.4.1.9.3.1
Information controlling VLAN configuration for a port. This is indexed by dot1dBasePort.
Status: current Access: not-accessible
OBJECT-TYPE    
  RadDot1qPortVlanEntry  

radDot1qPortStacking 1.3.6.1.4.1.164.4.1.9.3.1.1
This object indicates the port stacking operation: unmodify (2) = Do not add Tag. tag (3) = Add Tag to Untagged Frames. stack (4) = Add Tag to all Frames.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), unmodify(2), tag(3), stack(4)  

radDot1qPortCopyOriginVlanPriority 1.3.6.1.4.1.164.4.1.9.3.1.2
This object indicates whether use the original VLAN Priority of the frame, as the priority of the VLAN added by this port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

radDot1qPortDefaultVlanPriority 1.3.6.1.4.1.164.4.1.9.3.1.3
Default VLAN Frame priority of the VLAN added by this port.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

radDot1qPortTagStripping 1.3.6.1.4.1.164.4.1.9.3.1.4
This object indicates whether remove a tag from the frame on this port, frame with double tag will remain with one tag and frame with one tag will remain untagged.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

radDot1qPortEgressTagHandling 1.3.6.1.4.1.164.4.1.9.3.1.5
This object indicates how is the Egress VLAN Tag processed. It is mainly for use with Double Tagging.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(2), stacking(3), stripping(4)  

radDot1qPortIngressTagHandling 1.3.6.1.4.1.164.4.1.9.3.1.6
This object indicates how is the Ingress VLAN Tag processed. It is mainly for use with Double Tagging.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(2), stacking(3), stripping(4)  

radDot1qPortReplaceVlanPriority 1.3.6.1.4.1.164.4.1.9.3.1.7
This object indicates whether for each received tagged frame on this Bridge Port - VLAN Priority will be replaced by another Priority. no(2) = no repacement yes(3) = VLAN Priority will be replaced For Egate-100: When value is 'yes', the original Priority is replaced by the Default Priority.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

radDot1qPortVlanEthType 1.3.6.1.4.1.164.4.1.9.3.1.8
This object indicates the Ethernet Type. For some devices, it is applicable only when radDot1qPortStacking = stack.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

radDot1qPortVlanCnodeLevel1Agent 1.3.6.1.4.1.164.4.1.9.3.1.9
Specify if a Level 1 cNode agent is enabled or not for the bridge port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(2), enable(3)  

radBridgeGenCfgTable 1.3.6.1.4.1.164.4.1.9.4
A table containing Bridge configuration parameters.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RadBridgeGenCfgEntry

radBridgeGenCfgEntry 1.3.6.1.4.1.164.4.1.9.4.1
Describes an entry in the radBridgeGenCfgTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  RadBridgeGenCfgEntry  

radBridgeGenCfgIdx 1.3.6.1.4.1.164.4.1.9.4.1.1
This object indicates the Idx of the Agent Cnfg the following objects refer. 255=Temporary Cnfg. For Agents that support only one Configuration, this object will be constant=1.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..255  

radBridgeGenCfgIdx2 1.3.6.1.4.1.164.4.1.9.4.1.2
For Agents having more than one bridge, this index may be used as bridge index
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

radBridgeGenCfgBridgeAction 1.3.6.1.4.1.164.4.1.9.4.1.3
This variable enables the operator to perform one of the specified actions on the tables maintained by the Bridge. After performing the action, Agent will automatically Set the value of this variable to noOp(255).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER deleteLanTab(7), noOp(255)  

radBridgeAgingTimeSec 1.3.6.1.4.1.164.4.1.9.4.1.4
This variable duplicates scalar object dot1dTpAgingTimeThe of BRIDGE-MIB with configuration index and Bridge index. It defines the timeout period in seconds for aging out dynamically learned forwarding information. 802.1D-1990 recommends a default of 300 seconds.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 10..1000000  

radBridgeMngVlanId 1.3.6.1.4.1.164.4.1.9.4.1.5
This variable indicates the VLAN ID used for remote management traffic. 0 = Not Applicable.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

radBridgeLoopDetectVlanId 1.3.6.1.4.1.164.4.1.9.4.1.6
This variable indicates the VLAN ID used for Loop Detection packets. Valid values: 1 - 4095: VLAN ID 0 - Means that the Loop Detection is Disabled.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

radBridgeSplitHorizon 1.3.6.1.4.1.164.4.1.9.4.1.7
This object configure 'split horizon' switching between bridge Ports. - disable - normal (VLAN aware) bridge behavior. - enable - all packets, regardless their VLAN, coming from user side are blocked from being switched back to other user side bridge ports. - vlanBased - split horizon behavior is applicable only for specific VLANs, according to radBridgeDot1qVlanSplitHorizon.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enabled(3), vlanBased(4)  

radBridgeEthType 1.3.6.1.4.1.164.4.1.9.4.1.8
Value of Ethertype field in Ethernet frame. This field indicates which protocol is being transported in an ethernet frame.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

radBridgeAgingTime 1.3.6.1.4.1.164.4.1.9.5
This variable defines whether the Aging Time will be finite or infinite. When selecting the finite (3) value, the exact time will be determined by another variable of the standard MIB (ex. 1493.dot1dTpAgingTime). or by radBridgeAgingTime below.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), infinite(2), finite(3)  

radBridgeMngFlow 1.3.6.1.4.1.164.4.1.9.6
This variable defines whether the Management Flow is passed through the bridge (enable) or not (disable).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(2), enable(3)  

wanGen 1.3.6.1.4.1.164.3.1
OBJECT IDENTIFIER    

muxHub 1.3.6.1.4.1.164.3.2
OBJECT IDENTIFIER    

chasWanGen 1.3.6.1.4.1.164.3.1.1
OBJECT IDENTIFIER    

agnWanGen 1.3.6.1.4.1.164.3.1.2
OBJECT IDENTIFIER    

mdlWanGen 1.3.6.1.4.1.164.3.1.3
OBJECT IDENTIFIER    

prtWanGen 1.3.6.1.4.1.164.3.1.4
OBJECT IDENTIFIER    

mapWanGen 1.3.6.1.4.1.164.3.1.5
OBJECT IDENTIFIER    

diverseIfWanGen 1.3.6.1.4.1.164.3.1.6
OBJECT IDENTIFIER    

statAgnGen 1.3.6.1.4.1.164.3.1.2.1
OBJECT IDENTIFIER    

cnfgAgnGen 1.3.6.1.4.1.164.3.1.2.2
OBJECT IDENTIFIER    

cmprAgnGen 1.3.6.1.4.1.164.3.1.2.3
OBJECT IDENTIFIER    

alrBuffGen 1.3.6.1.4.1.164.3.1.2.4
OBJECT IDENTIFIER    

agnFlipDb 1.3.6.1.4.1.164.3.1.2.5
OBJECT IDENTIFIER    

agnSa 1.3.6.1.4.1.164.3.1.2.6
OBJECT IDENTIFIER    

agnListDecoding 1.3.6.1.4.1.164.3.1.2.7
OBJECT IDENTIFIER    

agnSystemDlci 1.3.6.1.4.1.164.3.1.2.8
OBJECT IDENTIFIER    

agnVoiceSwitching 1.3.6.1.4.1.164.3.1.2.9
OBJECT IDENTIFIER    

agnSigProfile 1.3.6.1.4.1.164.3.1.2.10
OBJECT IDENTIFIER    

agnSystemTs 1.3.6.1.4.1.164.3.1.2.11
OBJECT IDENTIFIER    

systemVoice 1.3.6.1.4.1.164.3.1.2.12
OBJECT IDENTIFIER    

statMdlGen 1.3.6.1.4.1.164.3.1.3.1
OBJECT IDENTIFIER    

cnfgMdlGen 1.3.6.1.4.1.164.3.1.3.2
OBJECT IDENTIFIER    

cmprMdlGen 1.3.6.1.4.1.164.3.1.3.3
OBJECT IDENTIFIER    

statPrtGen 1.3.6.1.4.1.164.3.1.4.1
OBJECT IDENTIFIER    

cnfgPrtGen 1.3.6.1.4.1.164.3.1.4.2
OBJECT IDENTIFIER    

cmprPrtGen 1.3.6.1.4.1.164.3.1.4.3
OBJECT IDENTIFIER    

agnMux 1.3.6.1.4.1.164.3.2.1
OBJECT IDENTIFIER    

mdlMux 1.3.6.1.4.1.164.3.2.2
OBJECT IDENTIFIER    

prtMux 1.3.6.1.4.1.164.3.2.3
OBJECT IDENTIFIER    

statPrtMux 1.3.6.1.4.1.164.3.2.3.1
OBJECT IDENTIFIER    

cnfgPrtMux 1.3.6.1.4.1.164.3.2.3.2
OBJECT IDENTIFIER    

statisPrtGen 1.3.6.1.4.1.164.3.1.4.1.3
OBJECT IDENTIFIER    

prtFrStatis 1.3.6.1.4.1.164.3.1.4.1.3.1
OBJECT IDENTIFIER    

prtCrStatis 1.3.6.1.4.1.164.3.1.4.1.3.2
OBJECT IDENTIFIER    

prtDlciStatis 1.3.6.1.4.1.164.3.1.4.1.3.3
OBJECT IDENTIFIER    

prtT1Statis 1.3.6.1.4.1.164.3.1.4.1.3.4
OBJECT IDENTIFIER    

prtClCnfg 1.3.6.1.4.1.164.3.2.3.2.1
OBJECT IDENTIFIER    

prtPh1MlCnfg 1.3.6.1.4.1.164.3.2.3.2.2
OBJECT IDENTIFIER    

prtPhPlCnfg 1.3.6.1.4.1.164.3.2.3.2.3
OBJECT IDENTIFIER    

prtLs2Cnfg 1.3.6.1.4.1.164.3.2.3.2.4
OBJECT IDENTIFIER    

prtHs4Cnfg 1.3.6.1.4.1.164.3.2.3.2.7
OBJECT IDENTIFIER    

prtHsiCnfg 1.3.6.1.4.1.164.3.2.3.2.8
OBJECT IDENTIFIER    

prtPVc4Cnfg 1.3.6.1.4.1.164.3.2.3.2.9
OBJECT IDENTIFIER    

prtHsrCnfg 1.3.6.1.4.1.164.3.2.3.2.10
OBJECT IDENTIFIER    

prtMbeCnfg 1.3.6.1.4.1.164.3.2.3.2.11
OBJECT IDENTIFIER    

prtTreCnfg 1.3.6.1.4.1.164.3.2.3.2.12
OBJECT IDENTIFIER    

prtLs6Cnfg 1.3.6.1.4.1.164.3.2.3.2.13
OBJECT IDENTIFIER    

prtVc3Cnfg 1.3.6.1.4.1.164.3.2.3.2.14
OBJECT IDENTIFIER    

prtVcPbxCnfg 1.3.6.1.4.1.164.3.2.3.2.15
OBJECT IDENTIFIER    

prtIsdnCnfg 1.3.6.1.4.1.164.3.2.3.2.16
OBJECT IDENTIFIER    

prtLogicalCnfg 1.3.6.1.4.1.164.3.2.3.2.17
OBJECT IDENTIFIER    

prtFrPlusCnfg 1.3.6.1.4.1.164.3.2.3.2.18
OBJECT IDENTIFIER    

prtMl4Cnfg 1.3.6.1.4.1.164.3.2.3.2.19
OBJECT IDENTIFIER    

prtAcmCnfg 1.3.6.1.4.1.164.3.2.3.2.20
OBJECT IDENTIFIER    

prtE2Cnfg 1.3.6.1.4.1.164.3.2.3.2.21
OBJECT IDENTIFIER    

prtLanWanCnfg 1.3.6.1.4.1.164.3.2.3.2.22
OBJECT IDENTIFIER    

chasVersion 1.3.6.1.4.1.164.3.1.1.1
An ASCII string for description and display of the agent chassis version.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

chasTotalNoOfSlt 1.3.6.1.4.1.164.3.1.1.2
This entry indicates the number of physical slots in the chassis.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

chasTotalNoOfIoSlt 1.3.6.1.4.1.164.3.1.1.3
This entry indicates the total number of physical IO slots in the chassis, (not all slots hardware should be occupied and active) .
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

chasTotalNoOfPsSlt 1.3.6.1.4.1.164.3.1.1.4
This entry indicates the number of physical Power Supply slots in the chassis.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

chasTotalNoOfClSlt 1.3.6.1.4.1.164.3.1.1.5
This entry indicates the number of physical Common Logic slots in the chassis.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

agnSDateFormat 1.3.6.1.4.1.164.3.1.2.1.1
This entry indicates the date and time format used for the agnSDateAndTimeCmd and for the alarm history report.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ddMMYYYY(1), mmDDYYYY(2), yyyyDDMM(3), yyyyMMDD(4)  

agnSDateCmd 1.3.6.1.4.1.164.3.1.2.1.2
This entry indicates the current date as it is known by the agent using its own real-time clock. The format would be as specified by the agnSDateFormat. This parameter can be set for time synchronization between the NMS and the Agent.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..255)  

agnSTimeCmd 1.3.6.1.4.1.164.3.1.2.1.3
This entry indicates the current time as it is known by the agent using its own real-time clock. This parameter can be set for time synchronization between the NMS and the Agent.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..255)  

agnSActiveCnfg 1.3.6.1.4.1.164.3.1.2.1.4
This entry specifies the unique identifier of the configuration, that is currently active and running.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

agnSEditCnfg 1.3.6.1.4.1.164.3.1.2.1.5
This entry indicates the unique identifier of the configuration that is currently loaded into the tmp working space for manipulation and update operations. Value of 255 means no config. is under editing process.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

agnSLastCnfgFlipTime 1.3.6.1.4.1.164.3.1.2.1.6
This entry indicates the Date & Time of the last flip to the current configuration at the agent.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

agnSLastCnfgFlipCause 1.3.6.1.4.1.164.3.1.2.1.7
This entry describes the flip's cause.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

agnSEditBy 1.3.6.1.4.1.164.3.1.2.1.8
This entry indicates which MMI application is working on the edited config. The editing phase starts at the first modify operation and ends after an update(load) operation.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(1), snmp(2), terCon1(3), terCon2(4), terInbandCon1(5), terInbandCon2(6), lcd(7)  

agnSClkSrc 1.3.6.1.4.1.164.3.1.2.1.9
This entry indicates the source of the system clock.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER master(1), fallback(2), internal(3)  

agnSAlrStatus 1.3.6.1.4.1.164.3.1.2.1.10
Indicates the alarm state in the agent level, i.e. lower level (card/port) alarms not included. critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(2), event(3), minor(4), major(5), warning(6), critical(7)  

agnSAlrStatusAll 1.3.6.1.4.1.164.3.1.2.1.11
Indicates the alarm state of the entire agent, i.e. including card and port alarms status. critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(2), event(3), minor(4), major(5), warning(6), critical(7)  

agnSMaskedAlrStat 1.3.6.1.4.1.164.3.1.2.1.12
Indicates the alarm state in the agent level,[ i.e. lower level (card/port) alarms not included] including Masked alarms. critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(2), event(3), minor(4), major(5), warning(6), critical(7)  

agnSMaskedAlrStatAll 1.3.6.1.4.1.164.3.1.2.1.13
Indicates the alarm state of the entire agent, i.e. including card and port alarms status,including Masked alarms. critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(2), event(3), minor(4), major(5), warning(6), critical(7)  

agnSTstStatAll 1.3.6.1.4.1.164.3.1.2.1.14
on(3) - when there is at least one test in progress in one of the agent cards, otherwise the value will be off(2).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(2), on(3)  

agnSAlrTable 1.3.6.1.4.1.164.3.1.2.1.15
List of agent related alarms and indications for alarms at system level.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnSAlrEntry

agnSAlrEntry 1.3.6.1.4.1.164.3.1.2.1.15.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AgnSAlrEntry  

agnSAlrIdx 1.3.6.1.4.1.164.3.1.2.1.15.1.1
A unique number to identify an entry in the alarm status table of the agent.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

agnSAlrCodeDescription 1.3.6.1.4.1.164.3.1.2.1.15.1.2
This attribute is a full text description of the alarm . The alarm description includes the following information: alarm code, alarm text, alarm severity, Masked or Inverted flag and counter.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

agnSAlrCode 1.3.6.1.4.1.164.3.1.2.1.15.1.3
A code identifying the alarm of an entry in the alarm status table at system level.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

agnSAlrSeverity 1.3.6.1.4.1.164.3.1.2.1.15.1.4
The severity of the alarm.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER event(3), minor(4), major(5), warning(6), critical(7)  

agnSAlrState 1.3.6.1.4.1.164.3.1.2.1.15.1.5
State of the alarm.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(2), on(3)  

agnSAlrCounter 1.3.6.1.4.1.164.3.1.2.1.15.1.6
A counter - how many times the alarm occured since last clear operation. ON and OFF Alarm will be counted separately.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

agnSAlrMask 1.3.6.1.4.1.164.3.1.2.1.15.1.7
Alarm mask : on/off.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(2), on(3)  

agnSAlrInvert 1.3.6.1.4.1.164.3.1.2.1.15.1.8
Alarm invert : on/off.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(2), on(3)  

agnSClearAlrCmd 1.3.6.1.4.1.164.3.1.2.1.16
Setting this attribute to ON, enforce a clear operation on all the agent(general) events. General alarms are alarms which are not specific to a card or port. The clear operation will not be applied for masked/inverted alarms.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

agnSClearAllAlrCmd 1.3.6.1.4.1.164.3.1.2.1.17
Setting this attribute to ON, enforce a clear operation on all MUX alarm events at the levels of agent, slots and ports. The clear operation will not be applied for masked/inverted alarms.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

agnSSanityCheckStatus 1.3.6.1.4.1.164.3.1.2.1.18
Upon completion of the Sanity check process on the TmpCnfg this attribute will be set to: FAIL(2) - when there is at least one error encountered and possibly some warnings. WARNING(3) - when there are only warnings. otherwise, the value will be OK(4). The value will be UNKNOWN(1) if changes were made in the TmpCnfg following the last Sanity check.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), fail(2), warning(3), ok(4)  

agnSNoOfSanityCheckErr 1.3.6.1.4.1.164.3.1.2.1.19
This entry indicates the number of errors/warnings discovered by the last SanityCheck process.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

agnSErrListTable 1.3.6.1.4.1.164.3.1.2.1.20
List of errors and warnings found during Sanity Check process.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnSErrListEntry

agnSErrListEntry 1.3.6.1.4.1.164.3.1.2.1.20.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AgnSErrListEntry  

agnSErrIdx 1.3.6.1.4.1.164.3.1.2.1.20.1.1
Unique number to identify an entry in the error list table. The maximum entry value cannot exceed the value of 'agnSNoOfSanityCheckErr'.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

agnSErrDescription 1.3.6.1.4.1.164.3.1.2.1.20.1.2
This attribute is a full text description of the sanity check error including error code, slot and port numbers related to the code .
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

agnSMaxNoOfCnfg 1.3.6.1.4.1.164.3.1.2.1.21
Maximum number of configurations that can be defined and stored in the MUX. If the mux has a large capacity, the maximum will be limited to 254.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

agnSCnfgTable 1.3.6.1.4.1.164.3.1.2.1.22
This table contains an entry per configuration. It indicates if the configuration is valid.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnSCnfgEntry

agnSCnfgEntry 1.3.6.1.4.1.164.3.1.2.1.22.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AgnSCnfgEntry  

agnSEntryIdx 1.3.6.1.4.1.164.3.1.2.1.22.1.1
Unique number to identify an entry in the configuration table.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

agnSEntryIsValid 1.3.6.1.4.1.164.3.1.2.1.22.1.2
This attribute indicates whether the specific configuration is valid in the MUX . Value of NO indicates: no such configuration in the MUX.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

agnCSanityCheckCmd 1.3.6.1.4.1.164.3.1.2.2.1
Setting this attribute to on(3) will initiate the process of Sanity check on the TmpCnfg. Upon completion the value will automatically be changed to off(2).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

agnCSaveCnfgIdxCmd 1.3.6.1.4.1.164.3.1.2.2.2
This attribute specifies the Id of the target RealCnfg to which the TmpCnfg should be transferred. Upon set command the MUX will initiate the Sanity-Check process first. If successful, the actual transfer will be performed. If warnings are detected, the user will have to perform the command again to confirm the operation. Setting this object a second time to the same value without performing any change in the database, will cause the result: agnSSanityCheckStatus = unknown
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..100  

agnCLoadCnfgIdxCmd 1.3.6.1.4.1.164.3.1.2.2.3
This attribute specifies the Id of the source Cnfg to be loaded into the TmpCnfg. Upon set operation the actual transfer will be initiated. The operation is valid only on Valid configurations (agnSEntryIsValid)
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..100  

agnCClkSrcTable 1.3.6.1.4.1.164.3.1.2.2.4
All the entries of this table are identical (have the same value) for all the configurations (1..100) except the TmpCnfg. The write operation into the Table Objects is valid only for the TmpCnfg entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnCClkSrcEntry

agnCClkSrcEntry 1.3.6.1.4.1.164.3.1.2.2.4.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AgnCClkSrcEntry  

agnCClkCnfgIdx 1.3.6.1.4.1.164.3.1.2.2.4.1.1
This attribute indicates the Idx of the Cnfg(1..100) being accessed and Idx 255 relates to the TmpCnfg.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

agnCClkSrcIdx 1.3.6.1.4.1.164.3.1.2.2.4.1.2
An index to the table. There are only two entries to this table. Index 1 points to the Master clock parameters and Index 2 points to the Fallback clock parameters
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..2  

agnCClkSrcMode 1.3.6.1.4.1.164.3.1.2.2.4.1.3
The source of the nodal timing.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER internal(1), rxClk(2), adaptive(3)  

agnCClkSrcSlt 1.3.6.1.4.1.164.3.1.2.2.4.1.4
This entry is valid only when we are working in rxClk mode. For an invalid entry, the return value will be '7fff'h.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

agnCClkSrcPrt 1.3.6.1.4.1.164.3.1.2.2.4.1.5
This entry is valid only when we are working in rxClk or adaptive mode. For an invalid entry, the return value will be '7fff'h. - For rxClk mode, the values can be: exPrt1 (1) , exPrt2 (2) , exPrt3 (3) , exPrt4 (4) , exPrt5 (5) , exPrt6 (6) , exPrt7 (7) , exPrt8 (8) , exPrt9 (9) , exPrt10 (10) , exPrt11 (11) , exPrt12 (12) , notApplicable (100), inPrt1 (101) , inPrt2 (102) , inPrt3 (103) , inPrt4 (104) - For adaptive mode, the value will be the ifIndex of the selected IP Bundle.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

agnCDeleteCnfgIdxCmd 1.3.6.1.4.1.164.3.1.2.2.5
Setting this attribute will delete the requested DB from the NVRAM .
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..100  

agnCDefaultCnfgIdxCmd 1.3.6.1.4.1.164.3.1.2.2.6
Setting this attribute will define the desired working configuration when no conditions of the Flip DB Table are fulfilled and no Net GO command was issued. This command will be accepted only if the Configuration number exists (agnSEntryIsValid=yes).
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..100  

agnCnfgDataTable 1.3.6.1.4.1.164.3.1.2.2.7
This table contains data about the agent configurations. The table will support only data about valid configurations of the agent.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnCnfgDataEntry

agnCnfgDataEntry 1.3.6.1.4.1.164.3.1.2.2.7.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AgnCnfgDataEntry  

agnCnfgIdx 1.3.6.1.4.1.164.3.1.2.2.7.1.1
This object indicates the Idx of the agent' Cnfg the following objects refer. 255=Temporary Cnfg (Set is done only to this configuration).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

agnCnfgDesc 1.3.6.1.4.1.164.3.1.2.2.7.1.2
This object is a description of the Configuration, entered by user, to enhance Cnfg recognition.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..30)  

agnCnfgUpdDate 1.3.6.1.4.1.164.3.1.2.2.7.1.3
This object indicates the date when last update of this configuration was performed, as it is known by the agent using its own real-time clock. The format would be as specified by the agnSDateFormat. When update is performed, the agent should save the date.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

agnCnfgUpdTime 1.3.6.1.4.1.164.3.1.2.2.7.1.4
This object indicates the time when last update of this configuration was performed, as it is known by the agent using its own real-time clock. When update is performed, the agent should save the time.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

agnCnfgUpdMnger 1.3.6.1.4.1.164.3.1.2.2.7.1.5
This object indicates the IP Address of the Manager who performed the last update of this configuration. When update is performed, the agent should save the IP Address of the Manager who commanded the update. That will enable a manager to know if he performed the last update, or another manager did.
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

agnCnfgAlarm 1.3.6.1.4.1.164.3.1.2.2.8
OBJECT IDENTIFIER    

agnCnfgAlrFilterWindow 1.3.6.1.4.1.164.3.1.2.2.8.1
Window of time, in seconds. During this Window, the alarms filter is performed. Same Window for all agent alarms that need filtering. Upon end of the Window, the state of the alarm is updated and a new Window starts. If no alarm needs filtering, this object's value will not be used.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..255  

agnCnfgAlrTable 1.3.6.1.4.1.164.3.1.2.2.8.2
This table enables the user to set attributes to each alarm. Setting for a non-existing entry agnCnfgAlrMask, agnCnfgAlrInvert or agnCnfgAlrFilter to 'yes'(or yesAndSave for Mask) will add this new entry to the table. Setting for an existing entry agnCnfgAlrMask/ agnCnfgAlrInvert/agnCnfgAlrFilter (one or more) to 'no' (noAndSave for Mask) so that ALL these objects' values are 'no' , will delete this entry from the table. For agnCnfgAlrMask, only if [(last saved value=noAndSave) AND (new value is 'no' or 'noAndSave')] the object's value is considered 'no' for deleting the entry. For some products (like MP, MPH, Vmux2100) the Active Alarms are always part of the table and cannot be removed even if their Mask/Invert/Filter are No.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnCnfgAlrEntry

agnCnfgAlrEntry 1.3.6.1.4.1.164.3.1.2.2.8.2.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AgnCnfgAlrEntry  

agnCnfgAlrCode 1.3.6.1.4.1.164.3.1.2.2.8.2.1.1
The alarm code. The following attributes refer this code.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

agnCnfgAlrSlot 1.3.6.1.4.1.164.3.1.2.2.8.2.1.2
The alarm slot. The following attributes apply for the alarm code and slot selected. all = the attributes apply to all slots. notApplicable = the selected alarm is for system level. For the Vmux2100 Main Board clA (3) is used.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER psA(1), psB(2), clA(3), clB(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), all(200), notApplicable(255)  

agnCnfgAlrPort 1.3.6.1.4.1.164.3.1.2.2.8.2.1.3
The alarm port. The following attributes apply for the alarm code,slot and port selected. 200 = all = the attributes apply to all ports of the selected slot. When selected Slot is 'all', only 'all' or 'notApplicable' are valid Port selections. notApplicable = the selected alarm is for system or card level. =255 for MP =100 for DXC - For MP: - valid cards' ports are: exPrt1(1)..exPrt16(16) inPrt1(101)..inPrt48 (148) - IP Bundles - For DXC, the port index will include the Slot, as for all DXC tables: [(IO Slot+10)&n] ; n=odd for external ports n=even for internal ports.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

agnCnfgAlrMask 1.3.6.1.4.1.164.3.1.2.2.8.2.1.4
An attribute defining the desired Mask state of an alarm . no - unmask (this command is not saved in agent's common database) noAndSave - unmask ; this command is saved in agent's common database yes - mask (this command is not saved in agent's common database) yesAndSave - mask ; this command is saved in agent's common database. Commands that are not saved, will be lost upon power-up or selected card removal.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER no(1), noAndSave(2), yes(3), yesAndSave(4)  

agnCnfgAlrInvert 1.3.6.1.4.1.164.3.1.2.2.8.2.1.5
An attribute defining the desired Invert state of an alarm . no - not inverted. yes - inverted. For MP, it is not applicable for alarms that are currently OFF.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

agnCnfgAlrFilter 1.3.6.1.4.1.164.3.1.2.2.8.2.1.6
An attribute defining if Filter is desired for the alarm . no - no filter. yes - filter activate. This filter is activated within a window of time defined by agnCnfgAlrFilterWindow. Its purpose is to avoid frequent changes of an alarm between ON/OFF states.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

agnCnfgAlrFilterSet 1.3.6.1.4.1.164.3.1.2.2.8.2.1.7
This is a top threshold causing the alarm that passes it, to be declared Set (ON) at the end of the respective window of time. - For alarms defined by default as state alarms (minor,major) this value will be in [%]. - For alarms defined by default as events, this value will be an integer meaning how many times this event should appear at least, during the window in order to be considered ON. The maximum value will be 255. This value should be greater than the one of agnCnfgAlrFilterReset. Agents that do not support Alarms Filter, will return 0.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

agnCnfgAlrFilterReset 1.3.6.1.4.1.164.3.1.2.2.8.2.1.8
This is a bottom threshold causing the alarm that does not pass it, to be declared Reset (ON) at the end of the respective window of time. - For alarms defined by default as state alarms (minor,major) this value will be in [%]. - For alarms defined by default as events, this value will be an integer meaning how many times this event should appear at most, during the window, in order to be considered OFF. This value should be less than the one of agnCnfgAlrFilterSet. Agents that do not support Alarms Filter, will return 0.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

agnCnfgAlrSeverity 1.3.6.1.4.1.164.3.1.2.2.8.2.1.9
An attribute defining desired severity of an alarm code per slot/port
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER event(3), minor(4), major(5), warning(6), critical(7)  

agnCnfgAlrReportTable 1.3.6.1.4.1.164.3.1.2.2.8.3
This table enables the user to configure the desired Alarm Reports according to alarms severity.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnCnfgAlrReportEntry

agnCnfgAlrReportEntry 1.3.6.1.4.1.164.3.1.2.2.8.3.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AgnCnfgAlrReportEntry  

agnCnfgAlrReportType 1.3.6.1.4.1.164.3.1.2.2.8.3.1.1
The alarm report type. trap - traps will be sent only for alarms having the selected On/Off severity or higher. buffer - only alarms having the selected On/Off severity and higher, will be reported to the buffer. relay - relay contact will be activated only for alarms having the selected On severity or higher. For products having 2 relays, this is the R1 Relay. alrLedOn/alrLedBlink - user should select a higher severity (ReportOn) for alrLedBlink than for alrLedOn (Blinking Led means a more severe alarm than steady ON Led). alrLedOn - MTCL-1 Alarm Led will be ON only when agnSAlrStatusAll equals the selected severity or higher, but lower severity than that selected for 'alrLedBlink'. For products having 2 LEDs, this is the Minor LED. alrLedBlink - MTCL-1 Alarm Led will Blink only when agnSAlrStatusAll equals the selected severity or higher. For products having 2 LEDs, this is the Major LED. relay2 - relay 2 contact will be activated only for alarms having the selected On severity or higher. This is the R2 Relay.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER trap(1), buffer(2), relay(3), alrLedOn(4), alrLedBlink(5), relay2(6)  

agnCnfgAlrStartReportOn 1.3.6.1.4.1.164.3.1.2.2.8.3.1.2
This object specifies the severity from which alarms will be reported. Alarms having this severity or higher, will be reported. This object specifies the report severity only for alarms that turn to ON state. noReport - no Report at all (for any severity).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noReport(2), event(3), minor(4), major(5), warning(6), critical(7)  

agnCnfgAlrStartReportOff 1.3.6.1.4.1.164.3.1.2.2.8.3.1.3
This object specifies the severity from which alarms will be reported. Alarms having this severity or higher, will be reported. This object specifies the report severity only for alarms that turn to OFF state. notApplicable - for 'relay','alrLedOn','alrLedBlink', 'relay2' report types, in MP. noReport - no Report at all (for any severity).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), noReport(2), event(3), minor(4), major(5), warning(6), critical(7)  

agnCOffsetCmd 1.3.6.1.4.1.164.3.1.2.2.9
An object defining special user request. notApplicable - is RO value for products that do not support this object. normal - nothing special u1 - user 1 - for all Voice cards, the DISPLAYED Tx and Rx Levels will have the following Offsets: - 2 Wires port: Tx Level: the base value (for 0dBm) = 0 Rx Level: the base value (for 0dBm) = -2 - 4 Wires port: Tx Level: the base value (for 0dBm) = -16 Rx Level: the base value (for 0dBm) = 7 The MIB and application DB will use the values without Offset.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), normal(2), u1(3)  

agnCT1E1RingTable 1.3.6.1.4.1.164.3.1.2.2.10
Configuration of all T1/E1 Ring ML cards and ports. The write operation into the table objects is valid only for the TmpCnfg. A Slot/Port that does not participate in the T1/E1 Ring, will not exist in this table. A ML port that exists in this table, cannot exist at the same time in the IO Redundancy table (sysCRdnTable).
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnCT1E1RingEntry

agnCT1E1RingEntry 1.3.6.1.4.1.164.3.1.2.2.10.1
An Entry in table agnCT1E1RingTable
Status: current Access: not-accessible
OBJECT-TYPE    
  AgnCT1E1RingEntry  

agnCT1E1RingCnfgIdx 1.3.6.1.4.1.164.3.1.2.2.10.1.1
This object indicates the Idx of the Cnfg(1..255) being accessed ; Idx of 255 relates to the TmpCnfg.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

agnCT1E1RingPrimeSlot 1.3.6.1.4.1.164.3.1.2.2.10.1.2
The slot number of the Primary card of the Ring Pair.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

agnCT1E1RingPrimePort 1.3.6.1.4.1.164.3.1.2.2.10.1.3
The port number in the Primary Card. For external ports, the value will be as that of the port in the card. Example: external-3 -> 3 external-4 -> 4 For internal ports, the value will be 100 + the port in the card. Example: internal-1 -> 101 internal-4 -> 104
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

agnCT1E1RingSecSlot 1.3.6.1.4.1.164.3.1.2.2.10.1.4
The slot number of the Secondary card of the Ring Pair.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

agnCT1E1RingSecPort 1.3.6.1.4.1.164.3.1.2.2.10.1.5
The port number in the Secondary Card. For external ports, the value will be as that of the port in the card. Example: external-3 -> 3 external-4 -> 4 For internal ports, the value will be 100 + the port in the card. Example: internal-1 -> 101 internal-4 -> 104
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

agnCT1E1RingRecTime 1.3.6.1.4.1.164.3.1.2.2.10.1.6
T1/E1 Ring Recovery Time (sec). Valid Values: 1..99, 65535. 65535=NA.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

agnCT1E1RingRowStatus 1.3.6.1.4.1.164.3.1.2.2.10.1.7
This parameter allows NMS to create/delete entries of this table. The only possible supported RowStatus vaules are active (1) and destroy (6).
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

agnCT1E1RingWTR 1.3.6.1.4.1.164.3.1.2.2.10.1.8
T1/E1 Ring Wait to Restore (sec). Valid Values: 0..999, 65535. 65535=NA. When the value <> 65535, the value of agnCT1E1RingRecTime must be 65535.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

agnCT1E1RingDualFailDetection 1.3.6.1.4.1.164.3.1.2.2.10.1.9
T1/E1 Ring - Dual Failure Detection enable/disable.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER disable(2), enable(3)  

agnCMainExitPort 1.3.6.1.4.1.164.3.1.2.2.11
An object defining the Main Exit Port for the Data of the device. In the Vmux-120 Device the Data can Exit via one of the 2 existing ports: 1. Ethernet port (2) 2. A port that can be E1 or T1 or a Serial Link (3).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), eth(2), e1T1SerialLink(3)  

agnCBuMlTable 1.3.6.1.4.1.164.3.1.2.2.12
Configuration for Primary, Secondary and Third Link. These are used for Link Backup.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnCBuMlEntry

agnCBuMlEntry 1.3.6.1.4.1.164.3.1.2.2.12.1
An Entry in table agnCBuMlTable
Status: current Access: not-accessible
OBJECT-TYPE    
  AgnCBuMlEntry  

agnCBuMlCnfgIdx 1.3.6.1.4.1.164.3.1.2.2.12.1.1
This object indicates the Index of the Configuration database (1..255) being accessed. Index of 255 relates to the Temporary Configuration.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

agnCBuMlRole 1.3.6.1.4.1.164.3.1.2.2.12.1.2
The Role of the Link. Primary Link is the Link that should usually work. If the Primary Link fails, the data will go through the Secondary Link. If both Primary and Secondary Links fail, the data will go through the Third Link, provided it is up.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER primary(2), secondary(3), third(4), fourth(5)  

agnCBuMlType 1.3.6.1.4.1.164.3.1.2.2.12.1.3
The Type of the Link. For E1/T1 the Link can be Link A - e1T1a or Link B - e1T1b.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(2), e1T1a(3), e1T1b(4), eth(5)  

agnCBuMlDefaultGateway 1.3.6.1.4.1.164.3.1.2.2.12.1.4
Default Gateway's IP Address.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

agnCBuMlSubnetMask 1.3.6.1.4.1.164.3.1.2.2.12.1.5
The Link subnet mask.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

agnCBuMlOamFrequency 1.3.6.1.4.1.164.3.1.2.2.12.1.6
Time in sec. between 2 OAM packets.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

agnCBuMlOamTimeoutCycles 1.3.6.1.4.1.164.3.1.2.2.12.1.7
No. of cycles the Link will send OAM packets without receiving a response from the remote Link before switching to the Backup Link.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

agnCBuMlWaitToRestore 1.3.6.1.4.1.164.3.1.2.2.12.1.8
This object defines traffic recovery time (in milliseconds) of the link after its recovery. This object is applicable only when Recovery Mode is revertive.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

agnCQ50Table 1.3.6.1.4.1.164.3.1.2.2.13
Table for the device Q50 parameters. Q50 is a Signaling protocol used between PBX devices. It is possible to control the initiation of calls using Q.50. This is useful for devices when there is a congestion.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnCQ50Entry

agnCQ50Entry 1.3.6.1.4.1.164.3.1.2.2.13.1
An Entry in table agnCQ50Table
Status: current Access: not-accessible
OBJECT-TYPE    
  AgnCQ50Entry  

agnCQ50CnfgIdx 1.3.6.1.4.1.164.3.1.2.2.13.1.1
This object indicates the Index of the Configuration database (1..255) being accessed. Index of 255 relates to the Temporary Configuration.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

agnCQ50StopCallsThresh 1.3.6.1.4.1.164.3.1.2.2.13.1.2
This object indicates the Bandwidth Threshold percent (%) above which new Calls from the PBX will be disabled.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

agnCQ50DiscardPktThresh 1.3.6.1.4.1.164.3.1.2.2.13.1.3
This object indicates the Bandwidth Threshold percent (%) above which voice packets will be discarded. Usually, the value selected should be higher than the value of agnCQ50StopCallsThresh.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

agnCQ50BlockNewModemVbdCallsThresh 1.3.6.1.4.1.164.3.1.2.2.13.1.4
This object indicates the Modem VBD Calls Threshold percent (%) above which new modem calls will be rejected.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

agnCQ50BlockNewModemRelayCallsThresh 1.3.6.1.4.1.164.3.1.2.2.13.1.5
This object indicates the Modem Relay Calls Threshold percent (%) above which new modem calls will be rejected.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

agnCmprTable 1.3.6.1.4.1.164.3.1.2.3.1
A table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnCmprEntry

agnCmprEntry 1.3.6.1.4.1.164.3.1.2.3.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AgnCmprEntry  

agnCmprTypIdx 1.3.6.1.4.1.164.3.1.2.3.1.1.1
This attribute indicates the Type of the Compressed being referred.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

agnCmprCnfgIdx 1.3.6.1.4.1.164.3.1.2.3.1.1.2
This attribute indicates the configuration to which the Compressed information is related.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

agnCmprVersion 1.3.6.1.4.1.164.3.1.2.3.1.1.3
This attribute indicates the version of the internal format of the Compressed data
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

agnCmprObj 1.3.6.1.4.1.164.3.1.2.3.1.1.4
This attribute is the compressed information itself.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

agnDlciCmprTable 1.3.6.1.4.1.164.3.1.2.3.2
A table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnDlciCmprEntry

agnDlciCmprEntry 1.3.6.1.4.1.164.3.1.2.3.2.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AgnDlciCmprEntry  

agnDlciCmprCnfgIdx 1.3.6.1.4.1.164.3.1.2.3.2.1.1
This attribute indicates the configuration to which the Compressed information is related.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

agnDlciCmprVersion 1.3.6.1.4.1.164.3.1.2.3.2.1.2
This attribute indicates the version of the internal format of the Compressed data
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

agnDlciCmprDlciIdx 1.3.6.1.4.1.164.3.1.2.3.2.1.3
This attribute indicates a unique identifier of the Dlci, the compressed information relates to. The values are between 16 - 991.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

agnDlciCmprObj 1.3.6.1.4.1.164.3.1.2.3.2.1.4
This attribute is the compressed information itself.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

agnAlarmsCmprTable 1.3.6.1.4.1.164.3.1.2.3.3
A table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnAlarmsCmprEntry

agnAlarmsCmprEntry 1.3.6.1.4.1.164.3.1.2.3.3.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AgnAlarmsCmprEntry  

agnAlarmsCmprVersion 1.3.6.1.4.1.164.3.1.2.3.3.1.1
This attribute indicates the version of the internal format of the Compressed data
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

agnAlarmsCmprAlarmIdx 1.3.6.1.4.1.164.3.1.2.3.3.1.2
A unique number to identify an entry in the alarm status table of the agent.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

agnAlarmsCmprObj 1.3.6.1.4.1.164.3.1.2.3.3.1.3
This attribute is the compressed information itself.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

agnAlrBufCmprTable 1.3.6.1.4.1.164.3.1.2.3.4
A table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnAlrBufCmprEntry

agnAlrBufCmprEntry 1.3.6.1.4.1.164.3.1.2.3.4.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AgnAlrBufCmprEntry  

agnAlrBufCmprVersion 1.3.6.1.4.1.164.3.1.2.3.4.1.1
This attribute indicates the version of the internal format of the Compressed data
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

agnAlrBufCmprAlarmIdx 1.3.6.1.4.1.164.3.1.2.3.4.1.2
A unique number to identify an entry in the history alarms buffer of the agent.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

agnAlrBufCmprObj 1.3.6.1.4.1.164.3.1.2.3.4.1.3
This attribute is the compressed information itself.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

agnSCmprErrListTable 1.3.6.1.4.1.164.3.1.2.3.5
A table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnSCmprErrListEntry

agnSCmprErrListEntry 1.3.6.1.4.1.164.3.1.2.3.5.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AgnSCmprErrListEntry  

agnSCmprErrVersion 1.3.6.1.4.1.164.3.1.2.3.5.1.1
The version of the compressed data
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

agnSCmprErrIdx 1.3.6.1.4.1.164.3.1.2.3.5.1.2
Unique number to identify an entry in the errors list table. The maximum entry value cannot exceed the value of 'agnSNoOfSanityCheckErr'.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

agnSCmprErrObj 1.3.6.1.4.1.164.3.1.2.3.5.1.3
This attribute is a full text description of the error, including: error code, slot and port numbers related to the code .
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

agnTsCmprTable 1.3.6.1.4.1.164.3.1.2.3.6
A table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnTsCmprEntry

agnTsCmprEntry 1.3.6.1.4.1.164.3.1.2.3.6.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AgnTsCmprEntry  

agnTsCmprVerIdx 1.3.6.1.4.1.164.3.1.2.3.6.1.1
This object indicates the version of the internal format of the Compressed data.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

agnTsCmprCnfgIdx 1.3.6.1.4.1.164.3.1.2.3.6.1.2
This object indicates the configuration to which the Compressed information is related. 255=temporary configuration. Set can be performed only to the temporary configuration.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

agnTsCmprSlotIdx 1.3.6.1.4.1.164.3.1.2.3.6.1.3
This object indicates the Slot to which the Compressed information is related. For MP-2100: IO-1..IO-12 = (5).. (16) For DXC-30 : IO-1..IO-15 = (5).. (19). NA=255.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

agnTsCmprPortIdx 1.3.6.1.4.1.164.3.1.2.3.6.1.4
This object indicates the Port within the Slot, to which the Compressed information is related. For Port Index see each product's spec.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

agnTsCmprPduIdx 1.3.6.1.4.1.164.3.1.2.3.6.1.5
This object indicates the PDU index within the same port. That provides for the case when one PDU is not sufficient for all TS Assignment data of the same port.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

agnTsCmprData 1.3.6.1.4.1.164.3.1.2.3.6.1.6
This object is the compressed information itself. It provides information about all TSs of a port.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

agnXCmprTable 1.3.6.1.4.1.164.3.1.2.3.7
A table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnXCmprEntry

agnXCmprEntry 1.3.6.1.4.1.164.3.1.2.3.7.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AgnXCmprEntry  

agnXCmprTypIdx 1.3.6.1.4.1.164.3.1.2.3.7.1.1
This attribute indicates the Type of the Compressed being referred. One of the types is V5.1 Variant data.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

agnXCmprVersion 1.3.6.1.4.1.164.3.1.2.3.7.1.2
This attribute indicates the version of the internal format of the Compressed data.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

agnXCmprIdx3 1.3.6.1.4.1.164.3.1.2.3.7.1.3
3rd index - can be used for any purpose according to the agnXCmprTypIdx. Example: for V5.1 Variant, this attribute indicates the configuration to which the Compressed information is related. 255=temporary configuration. Set can be performed only to the temporary configuration.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

agnXCmprIdx4 1.3.6.1.4.1.164.3.1.2.3.7.1.4
4th index - can be used for any purpose according to the agnXCmprTypIdx. Example: for V5.1 Variant,this attribute indicates a unique number of the slot position where the card is inserted. Valid values: psA(1),psB(2),clA(3),clB(4),io1(5)..io12(16); notApplicable=255.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

agnXCmprIdx5 1.3.6.1.4.1.164.3.1.2.3.7.1.5
5th index - can be used for any purpose according to the agnXCmprTypIdx. Example: for V5.1 Variant,this attribute indicates a unique identifier of the port the compressed information relates to. Valid values: exPrt1 (1) .. exPrt12 (12) , inPrt1 (101) .. inPrt48 (148).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

agnXCmprIdx6 1.3.6.1.4.1.164.3.1.2.3.7.1.6
6th index - can be used for any purpose according to the agnXCmprTypIdx. Example: for V5.1 Variant,this attribute indicates the Variant index. Valid values are: 0..127, 255 (= temp cnfg).Set can be performed only to the temporary configuration.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

agnXCmprIdx7 1.3.6.1.4.1.164.3.1.2.3.7.1.7
7th index - can be used for any purpose according to the agnXCmprTypIdx. Example: for V5.1 Variant,this attribute is not needed. Therefore, its value will be always 255=notApplicable.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

agnXCmprObj 1.3.6.1.4.1.164.3.1.2.3.7.1.8
This attribute is the compressed information itself.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

agnLinkMapTable 1.3.6.1.4.1.164.3.1.5.1
A table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnLinkMapEntry

agnLinkMapEntry 1.3.6.1.4.1.164.3.1.5.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AgnLinkMapEntry  

mapLinkId 1.3.6.1.4.1.164.3.1.5.1.1.1
A unique identifier of the link
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

mapLinkSltIdx 1.3.6.1.4.1.164.3.1.5.1.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries clA(3), io6(10)..io12(16) are not valid.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noConnect(2), clA(3), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

mapLinkPrtIdx 1.3.6.1.4.1.164.3.1.5.1.1.3
This attribute indicates a unique port number.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6), exPrt7(7), exPrt8(8), exPrt9(9), exPrt10(10), exPrt11(11), exPrt12(12), noConnect(100), inPrt1(101), inPrt2(102), inPrt3(103), inPrt4(104), inPrt5(105), inPrt6(106), inPrt7(107), inPrt8(108), inPrt9(109), inPrt10(110), inPrt11(111), inPrt12(112)  

mapLinkStatus 1.3.6.1.4.1.164.3.1.5.1.1.4
This attribute indicates the status of the link between the two muxes
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), down(2), up(3)  

alrBufTable 1.3.6.1.4.1.164.3.1.2.4.1
A table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AlrBufEntry

alrBufEntry 1.3.6.1.4.1.164.3.1.2.4.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AlrBufEntry  

alrBufIdx 1.3.6.1.4.1.164.3.1.2.4.1.1.1
This attribute indicates a unique number to identify this entry
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

alrBufDescription 1.3.6.1.4.1.164.3.1.2.4.1.1.2
This entry is a unique text description of the alarm in the buffer. The alarm description includes the following information: alarm code, slot id, card type, channel id , alarm text, alarm status, masked flag and event counter
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

alrBufCode 1.3.6.1.4.1.164.3.1.2.4.1.1.3
A code identifying the alarm of an entry in the alarm buffer table.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

alrBufSlot 1.3.6.1.4.1.164.3.1.2.4.1.1.4
The slot number this alarm refers to. When the alarm refers to a system alarm, the value will be 'notApplicable(255)'.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER psA(1), psB(2), clA(3), clB(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), notApplicable(255)  

alrBufPort 1.3.6.1.4.1.164.3.1.2.4.1.1.5
The port number this alarm refers to. If the port number is irrelevant to this alarm (if it is a system/card level alarm) the value will be 9999.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

alrBufSeverity 1.3.6.1.4.1.164.3.1.2.4.1.1.6
The severity of the alarm.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER event(3), minor(4), major(5), warning(6), critical(7)  

alrBufState 1.3.6.1.4.1.164.3.1.2.4.1.1.7
State of the alarm (On/Off).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(2), on(3)  

alrBufferClearCmd 1.3.6.1.4.1.164.3.1.2.4.2
Setting this attribute to ON, will enforce a clear operation on the Alarms Buffer. Upon completion, the value will automatically change to off(2). For MP-2100/2200, this command will not really erase the Alarm Buffer, but is only an ACK of seeing the Buffer. It marks a pointer of the last entry's alrBufIdx, in order to allow view of new alarms entered after this pointer (alrBufIdxUponLastAck).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

alrBufIdxUponLastAck 1.3.6.1.4.1.164.3.1.2.4.3
This attribute indicates the value of alrBufIdx for the last existing entry of alrBufTable, when alrBufferClearCmd was last Set to on(3). That will enable a user to see only Alarms that entered the alrBufTable after last Set of alrBufferClearCmd, by GetNext of alrBufDescription with this index.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

agnCAgendaTable 1.3.6.1.4.1.164.3.1.2.5.1
This table devides the week days into categories needed for DB flip consideration.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnCAgendaEntry

agnCAgendaEntry 1.3.6.1.4.1.164.3.1.2.5.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AgnCAgendaEntry  

agnCAgendaCnfgIdx 1.3.6.1.4.1.164.3.1.2.5.1.1.1
Active or Temporary Agenda Table. Both configurations can be read but only the Temporary can be written to.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER active(1), temporary(255)  

agnCAgendaDayIdx 1.3.6.1.4.1.164.3.1.2.5.1.1.2
Day of week
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER sunday(1), monday(2), tuesday(3), wednesday(4), thursday(5), friday(6), saturday(7)  

agnCAgendaDayCategory 1.3.6.1.4.1.164.3.1.2.5.1.1.3
The Category of the Day
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER fullWorkday(1), partialWorkday(2), weekend(3)  

agnCFlipNetEventsTable 1.3.6.1.4.1.164.3.1.2.5.2
This table holds the Net Events the MUX should trace
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnCFlipNetEventsEntry

agnCFlipNetEventsEntry 1.3.6.1.4.1.164.3.1.2.5.2.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AgnCFlipNetEventsEntry  

agnCFlipNetEventsCnfgIdx 1.3.6.1.4.1.164.3.1.2.5.2.1.1
Active or Temporary Net Events Table. Both configurations can be read but only the Temporary can be written to.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER active(1), temporary(255)  

agnCFlipNetEventIdx 1.3.6.1.4.1.164.3.1.2.5.2.1.2
Entry within the table
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..10  

agnCFlipNetEventActive 1.3.6.1.4.1.164.3.1.2.5.2.1.3
Indicates if the entry is valid. In order to Add/Modify parameters of an entry, this object should be set to Yes. In order to delete an entry, this object should be Set to No.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

agnCFlipNetEventType 1.3.6.1.4.1.164.3.1.2.5.2.1.4
The Net Event type
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER time(1), linkDown(2), congestion(3)  

agnCFlipNetEventNo 1.3.6.1.4.1.164.3.1.2.5.2.1.5
The Net Event No. (Bit Index)
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..512  

agnCFlipNetEventSlot 1.3.6.1.4.1.164.3.1.2.5.2.1.6
The slot to which the net event relates . Not applicable for time event
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), clA(3), clB(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

agnCFlipNetEventPort 1.3.6.1.4.1.164.3.1.2.5.2.1.7
The port within the relevant slot. Valid values: - extPrt1(1)..exPrt16(16) - notApplicable(100) - inPrt1(101)..inPrt84(184)
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

agnCFlipNetEventISD 1.3.6.1.4.1.164.3.1.2.5.2.1.8
The time in seconds since the Net Event was reported as ON until it is considered as ON. Not relevant for time events.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..999  

agnCFlipNetEventOSD 1.3.6.1.4.1.164.3.1.2.5.2.1.9
The time in seconds since the net event was reported as OFF until it is considered as OFF. Not relevant for time events.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..999  

agnCFlipNetEventDayType 1.3.6.1.4.1.164.3.1.2.5.2.1.10
The time event relates to all days defined in this category in the agnCAgendaTable. Applicable only for time event
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), fullWorkday(2), partialWorkday(3), weekend(4)  

agnCFlipNetEventStartTime 1.3.6.1.4.1.164.3.1.2.5.2.1.11
The time event will be activated at this time. The format is hh:mm.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(5)  

agnCFlipNetEventEndTime 1.3.6.1.4.1.164.3.1.2.5.2.1.12
The time event will be deactivated at this time. The format is hh:mm.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(5)  

agnCFlipTable 1.3.6.1.4.1.164.3.1.2.5.3
The DB Flip Decisions Table
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnCFlipEntry

agnCFlipEntry 1.3.6.1.4.1.164.3.1.2.5.3.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AgnCFlipEntry  

agnCFlipCnfgIdx 1.3.6.1.4.1.164.3.1.2.5.3.1.1
Active or Temporary Flip Decisions Table. Both configurations can be read but only the Temporary can be written to.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER active(1), temporary(255)  

agnCFlipIdx 1.3.6.1.4.1.164.3.1.2.5.3.1.2
Entry number within the table
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..10  

agnCFlipActive 1.3.6.1.4.1.164.3.1.2.5.3.1.3
Indicates if the entry is valid. In order to Add/Modify parameters of an entry this object should be Set to Yes. In order to delete an entry, this object should be Set to No.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

agnCFlipLogicalExp 1.3.6.1.4.1.164.3.1.2.5.3.1.4
A logical expression composed of events numbers (which were configured in the 'AgnCFlipNetEvantsTable') and logical operators ('|', '&', '!', '(', ')') between them. e.g - (1 & !2) | (121 & 230)
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..20)  

agnCFlipDbNo 1.3.6.1.4.1.164.3.1.2.5.3.1.5
The ID of the required DB
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..10  

agnCFlipDiscardDe 1.3.6.1.4.1.164.3.1.2.5.3.1.6
Indicates whether the Mux should start discarding all DE. (MP3000 Only).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

agnFlipDbControls 1.3.6.1.4.1.164.3.1.2.5.4
OBJECT IDENTIFIER    

agnCFlipDbSanityCheckCmd 1.3.6.1.4.1.164.3.1.2.5.4.1
Setting this attribute to on(3) will initiate the process of Sanity check on the Temp Flip Db and automatically be changed to off(2).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

agnCSaveFlipDbCmd 1.3.6.1.4.1.164.3.1.2.5.4.2
Setting this attribute to on(3) will initiate the process of Sanity check on the Temp Flip Db and if it is OK, it will save the Flip Db in the NVRAM, activating the new Flip DB . If check detects errors, the save will not be performed. Afterwards, the object's value will change automatically to off(2).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

agnCSaveNetCnfgIdxCmd 1.3.6.1.4.1.164.3.1.2.5.4.3
This attribute specifies the Id of the target NVRAM Cnfg to which the TmpCnfg should be transferred. Upon set command the MUX will initiate the Sanity-Check process first. If successful, the actual transfer will be performed. If warnings are detected, the user will have to perform the command again to confirm the operation. Setting this object a second time to the same value without performing any change in the database, will cause the result: agnSSanityCheckStatus = unknown. This attribute doesn't cause actual Flip.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..10  

agnCSaveNetFlipDbCmd 1.3.6.1.4.1.164.3.1.2.5.4.4
Setting this attribute to on(3) will save the Temp Flip DB Into the NVRAM without actual flip.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

agnCNetGoCmd 1.3.6.1.4.1.164.3.1.2.5.4.5
Setting this attribute to On will broadcast a 'GO' command to the network. When a Mux receives a 'GO' command it issues a delay for 'agnCNetDelay' seconds and then activates the DB which was pre-defined by one of the commands : 'agnCSaveNetCnfgIdxCmd' or 'agnCSaveNetFlipDbCmd'.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

agnCNetDelay 1.3.6.1.4.1.164.3.1.2.5.4.6
This attribute determines the period of time in seconds that takes for a message to be transferred over all the network. After a 'GO' command the MUX issues a delay of 'agnCNetDelay' before activating the appropriate DB. The delay will be applied only after performing agnCSaveFlipDbCmd.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..999  

agnCNetEventsBcast 1.3.6.1.4.1.164.3.1.2.5.4.7
This object determines if the Net Events will be Broadcasted to other Muxes of the Net or not. disabled - Net Events will NOT be Broadcasted enabled - Net Events will be Broadcasted. Default=disabled. The value will be applied only after performing agnCSaveFlipDbCmd.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(2), enabled(3)  

agnCNetEventsBcastInterval 1.3.6.1.4.1.164.3.1.2.5.4.8
When agnCNetEventsBcast is enabled, this object determines the interval of time in seconds, between two consecutive Net Events transferred over the network. Default=40 sec. The interval will be applied only after performing agnCSaveFlipDbCmd.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 10..60  

agnSaSwchStatus 1.3.6.1.4.1.164.3.1.2.6.1
This object indicates the status of the switches on the stand-alone unit. Each switch is represented by a bit. The status is a sum of 2**n, according to the bits: bit 0 NMS (LSB) bit 1 Terminal '1' = forces the DCE to be terminal with Rate=9600bps, Data bits=8, Stop bits=1 bit 2 Xray bit 3 SW-Load '1' = when SW is loaded bit 4 DBS Default of all bits=0 When the status of these switches is unknown, the value of this object is 255.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

agnListDecodingTable 1.3.6.1.4.1.164.3.1.2.7.1
A decoding table . For each type of list, a description is given for each existing code.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnListDecodingEntry

agnListDecodingEntry 1.3.6.1.4.1.164.3.1.2.7.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AgnListDecodingEntry  

agnListDecodingType 1.3.6.1.4.1.164.3.1.2.7.1.1.1
The type of list the decoding data refers to. alr - Alarms list sanity - Sanity Check Error list. counter - Counter type of ifPerfCounterType
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER alr(1), sanity(2), counter(3)  

agnListDecodingCode 1.3.6.1.4.1.164.3.1.2.7.1.1.2
The specific code for which decoding is needed.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

agnListDecodingDescription 1.3.6.1.4.1.164.3.1.2.7.1.1.3
The description fitting the specific code and type of list required.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

agnListDecodingDefState 1.3.6.1.4.1.164.3.1.2.7.1.1.4
This object is applicable only for agnListDecodingType=alr. It reports the default state/severity of each alarm. User can change the severity of the alarms defined by this default via the agnListDecodingSeverity object.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), event(3), minor(4), major(5), warning(6), critical(7)  

agnListDecodingSeverity 1.3.6.1.4.1.164.3.1.2.7.1.1.5
This object is applicable only for agnListDecodingType=alr. It enables the user to select a severity for each alarm. The severity is set per alarm code (same for all slots/ports using this code). event - can be set only for an alarm that is defined by default as 'event'. User can change the severity of the alarms defined by default as minor or major. The severity of an event may be set to another severity, but the change will actually happen only if the event threshold is active and passed the Set/ON condition. An event alarm that passed the threshold and changed its severity, will return automatically to event severity when meeting its Reset/OFF condition.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), event(3), minor(4), major(5), warning(6), critical(7)  

agnListDecodingAcmRelaySlt 1.3.6.1.4.1.164.3.1.2.7.1.1.6
This object indicates the ACM slot, desired for outbound relay (report) for the selected alarm. In the ?004 Unit the entries io6(10)..io12(16) are not valid. none - when agnListDecodingType=alr AND the selected alarm should not be reported by an ACM card. notApplicable - when agnListDecodingType=sanity OR when [agnListDecodingType=alr and there is no ACM card installed in the Mux].
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

agnListDecodingAcmRelayPrt 1.3.6.1.4.1.164.3.1.2.7.1.1.7
This object indicates the ACM port within the slot, desired for outbound relay (report) for the selected alarm. notApplicable - when agnListDecodingType=sanity OR when agnListDecodingAcmRelaySlt=notApplicable.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), notApplicable(255)  

agnDlciTable 1.3.6.1.4.1.164.3.1.2.8.1
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnDlciEntry

agnDlciEntry 1.3.6.1.4.1.164.3.1.2.8.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AgnDlciEntry  

agnDlciCnfgIdx 1.3.6.1.4.1.164.3.1.2.8.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

agnDlciLSltIdx 1.3.6.1.4.1.164.3.1.2.8.1.1.2
This attribute indicates a unique slot position where the card is inserted. This is the Source Slot of the DLCI. vs=Voice Switching In the ?004 Unit the entries io6(10)..io16) are not valid. For ISDN BRI ports of MX300/30 units: io1(5) = isdn1(5) and io2(6) = isdn2(6) LSlotIdx is defined according one of the following possiblities: 1. LSlotIdx is < HSlotIdx. 2. LSlotIdx is = HSlotIdx and LPrtIdx is < HPrtIdx. 3. LSlotIdx is = HSlotIdx and LPrtIdx is = HPrtIdx but LIdx is < HIdx.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER cl(3), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), vs(254), notApplicable(255)  

agnDlciLPrtIdx 1.3.6.1.4.1.164.3.1.2.8.1.1.3
This attribute indicates a unique external or internal port number, including linkSelector or encapsulator. This is the Source Port of the DLCI. 100=noConnect (for voice switching) LPrtIdx is defined according one of the following possiblities: 1. LSlotIdx is < HSlotIdx. 2. LSlotIdx is = HSlotIdx and LPrtIdx is < HPrtIdx. 3. LSlotIdx is = HSlotIdx and LPrtIdx is = HPrtIdx but LIdx is < HIdx.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

agnDlciLIdx 1.3.6.1.4.1.164.3.1.2.8.1.1.4
This attribute indicates a unique index for each possible used DLCI(16..991). This is the Source Side of the DLCI. 0=notApplicable (for voice switching) LIdx is defined according one of the following possiblities: 1. LSlotIdx is < HSlotIdx. 2. LSlotIdx is = HSlotIdx and LPrtIdx is < HPrtIdx. 3. LSlotIdx is = HSlotIdx and LPrtIdx is = HPrtIdx but LIdx is < HIdx.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..991  

agnDlciHSltIdx 1.3.6.1.4.1.164.3.1.2.8.1.1.5
This attribute indicates a unique slot position In the Mux where the DLCI is routed to - Destination Slot. For ISDN BRI ports of MX300/30 units: io1(5) = isdn1(5) and io2(6) = isdn2(6) In the ?004 Unit the entries io6(10)..io16) are not valid
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER cl(3), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

agnDlciHPrtIdx 1.3.6.1.4.1.164.3.1.2.8.1.1.6
This attribute indicates a unique port number where the DLCI is routed to - Destination Port.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

agnDlciHIdx 1.3.6.1.4.1.164.3.1.2.8.1.1.7
This attribute indicates a unique internal connection DLCI number where the Source DLCI is routed to - the Destination Side of the DLCI.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..991  

agnDlciTxBc 1.3.6.1.4.1.164.3.1.2.8.1.1.8
This attribute indicates a unique Tx committed bandwidth on the user transmit line or at the port receive line.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER full(1), zero(2), txBc5100bps(3), txBc6400bps(4), txBc8300bps(5), txBc9600bps(6), txBc14400bps(7), txBc19200bps(8), txBc28800bps(9), txBc32000bps(10), txBc38400bps(11), txBc48000bps(12), txBc56000bps(13), txBc57600bps(14), txBc64Kbps(15), txBc128Kbps(16), txBc192Kbps(17), txBc256Kbps(18), txBc320Kbps(19), txBc384Kbps(20), txBc448Kbps(21), txBc512Kbps(22), txBc768Kbps(23), txBc896Kbps(24), txBc1024Kbps(25), txBc1152Kbps(26), txBc1280Kbps(27), txBc1344Kbps(28), txBc1472Kbps(29), txBc1600Kbps(30), txBc1728Kbps(31), txBc1856Kbps(32), txBc1920Kbps(33), txBc1984Kbps(34), txBc2048Kbps(35), txBc16000bps(36), txBc112Kbps(37), txBc168Kbps(38), txBc224Kbps(39), txBc336Kbps(40), txBc672Kbps(41), txBc1536Kbps(42), txBc1792Kbps(43)  

agnDlciTxBe 1.3.6.1.4.1.164.3.1.2.8.1.1.9
This attribute indicates a unique Tx excess bandwidth on the user transmit line or at the port receive line.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER full(1), zero(2), txBe5100bps(3), txBe6400bps(4), txBe8300bps(5), txBe9600bps(6), txBe14400bps(7), txBe19200bps(8), txBe28800bps(9), txBe32000bps(10), txBe38400bps(11), txBe48000bps(12), txBe56000bps(13), txBe57600bps(14), txBe64Kbps(15), txBe128Kbps(16), txBe192Kbps(17), txBe256Kbps(18), txBe320Kbps(19), txBe384Kbps(20), txBe448Kbps(21), txBe512Kbps(22), txBe768Kbps(23), txBe896Kbps(24), txBe1024Kbps(25), txBe1152Kbps(26), txBe1280Kbps(27), txBe1344Kbps(28), txBe1472Kbps(29), txBe1600Kbps(30), txBe1728Kbps(31), txBe1856Kbps(32), txBe1920Kbps(33), txBe1984Kbps(34), txBe2048Kbps(35), txBe16000bps(36), txBe112Kbps(37), txBe168Kbps(38), txBe224Kbps(39), txBe336Kbps(40), txBe672Kbps(41), txBe1536Kbps(42), txBe1792Kbps(43)  

agnDlciRxBc 1.3.6.1.4.1.164.3.1.2.8.1.1.10
This attribute indicates a unique Rx committed bandwidth on the user receive line or at the port transmit line.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER full(1), zero(2), rxBc5100bps(3), rxBc6400bps(4), rxBc8300bps(5), rxBc9600bps(6), rxBc14400bps(7), rxBc19200bps(8), rxBc28800bps(9), rxBc32000bps(10), rxBc38400bps(11), rxBc48000bps(12), rxBc56000bps(13), rxBc57600bps(14), rxBc64Kbps(15), rxBc128Kbps(16), rxBc192Kbps(17), rxBc256Kbps(18), rxBc320Kbps(19), rxBc384Kbps(20), rxBc448Kbps(21), rxBc512Kbps(22), rxBc768Kbps(23), rxBc896Kbps(24), rxBc1024Kbps(25), rxBc1152Kbps(26), rxBc1280Kbps(27), rxBc1344Kbps(28), rxBc1472Kbps(29), rxBc1600Kbps(30), rxBc1728Kbps(31), rxBc1856Kbps(32), rxBc1920Kbps(33), rxBc1984Kbps(34), rxBc2048Kbps(35), rxBc16000bps(36), rxBc112Kbps(37), rxBc168Kbps(38), rxBc224Kbps(39), rxBc336Kbps(40), rxBc672Kbps(41), rxBc1536Kbps(42), rxBc1792Kbps(43)  

agnDlciRxBe 1.3.6.1.4.1.164.3.1.2.8.1.1.11
This attribute indicates a unique Rx excess bandwidth on the user receive line or at the port transmit line.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER full(1), zero(2), rxBe5100bps(3), rxBe6400bps(4), rxBe8300bps(5), rxBe9600bps(6), rxBe14400bps(7), rxBe19200bps(8), rxBe28800bps(9), rxBe32000bps(10), rxBe38400bps(11), rxBe48000bps(12), rxBe56000bps(13), rxBe57600bps(14), rxBe64Kbps(15), rxBe128Kbps(16), rxBe192Kbps(17), rxBe256Kbps(18), rxBe320Kbps(19), rxBe384Kbps(20), rxBe448Kbps(21), rxBe512Kbps(22), rxBe768Kbps(23), rxBe896Kbps(24), rxBe1024Kbps(25), rxBe1152Kbps(26), rxBe1280Kbps(27), rxBe1344Kbps(28), rxBe1472Kbps(29), rxBe1600Kbps(30), rxBe1728Kbps(31), rxBe1856Kbps(32), rxBe1920Kbps(33), rxBe1984Kbps(34), rxBe2048Kbps(35), rxBe16000bps(36), rxBe112Kbps(37), rxBe168Kbps(38), rxBe224Kbps(39), rxBe336Kbps(40), rxBe672Kbps(41), rxBe1536Kbps(42), rxBe1792Kbps(43)  

agnDlciPriority 1.3.6.1.4.1.164.3.1.2.8.1.1.12
This attribute indicates a unique priority of the pcv. 1 is the lowest priority and 7 is the highest priority.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 1..8  

agnDlciStatus 1.3.6.1.4.1.164.3.1.2.8.1.1.13
This attribute indicates the status of the pvc. The status is disconnected(1) when one of the sides is programmed as not connected
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER disconnected(1), connected(2)  

agnDlciSpoofing 1.3.6.1.4.1.164.3.1.2.8.1.1.14
This object refers to sending of RIP messages: - yes : RIP messages will be sent ONLY if there is a change in the Net. - no : RIP messages will be always sent. This object is relevant only when one side of the DLCI is a CL-NMS interface. Default=no.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

agnDlciFunnelEnable 1.3.6.1.4.1.164.3.1.2.8.1.1.15
This object selects Funnel activation: - disabled: Funnel operation will be disabled. The agnDlciTxBe and agnDlciTxBc values are not used for funneling. - enabled : Funnel operation will be enabled both for Source and Destination of the DLCI. The agnDlciTxBe and agnDlciTxBc values are used for funneling calculations. - source: Funnel operation will be enabled only for the Source of the DLCI. - destination:Funnel operation will be enabled only for the Destination of the DLCI. This object is relevant only for an encapsulating DLCI. In case of a Link Selector DLCI, the agnDlciTxBe and agnDlciTxBc values are used for bandwidth of Link Selector. Default=disabled.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER disabled(2), enabled(3), source(4), destination(5)  

agnDlciRoutingProtocol 1.3.6.1.4.1.164.3.1.2.8.1.1.16
This object is relevant only when one side of the DLCI is a CL-NMS interface. It defines which Routing Protocol will be used for management via CL-NMS port. notApplicable will be used for all slots but CL. rip is a proprietary rip protocol. Default=rip.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER notApplicable(1), rip(2), rip2(3), none(4)  

agnDlciRowStatus 1.3.6.1.4.1.164.3.1.2.8.1.1.17
This attribute allows to create/delete a row in this table. For creating a row, the NMS should set agnRowStatus.255.id2.id3.id4.id5.id6.id7 = active(1). For destroying a row, the NMS should set: agnRowStatus.255.id2.id3.id4.id5.id6.id7 = destroy(6). Only rows with status active(1) are relevant. The only possible supported RowStatus vaules are active (1) and destroy (6).
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

agnVoiceSwConfTable 1.3.6.1.4.1.164.3.1.2.9.1
MXcess Configuration for Voice Switching.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnVoiceSwConfEntry

agnVoiceSwConfEntry 1.3.6.1.4.1.164.3.1.2.9.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AgnVoiceSwConfEntry  

agnVoiceSwConfIdx 1.3.6.1.4.1.164.3.1.2.9.1.1.1
Active or Temporary Table. Both configurations can be read but only the Temporary can be written to.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER active(1), temporary(255)  

agnVoiceSwConfZoneId 1.3.6.1.4.1.164.3.1.2.9.1.1.2
1 or 2 digits, (0-9)(1-9).
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..2)  

agnVoiceSwConfNodeId 1.3.6.1.4.1.164.3.1.2.9.1.1.3
1, 2 or 3 digits, (1-9),(0-9),(0-9).
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..3)  

agnVoiceSwConfNoOfHops 1.3.6.1.4.1.164.3.1.2.9.1.1.4
Number of hops the frame will go through the net before deciding to discard the frame (like time-to-live in IP). 0 = notApplicable Default=20 .
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..20  

agnVoiceSwConfSidt 1.3.6.1.4.1.164.3.1.2.9.1.1.5
SIDT: Short Inter Digit Timeout used as timer (in sec.) between digits after routing is completed. The timeout indicates end of dialing and the call can then be setup. 0 = notApplicable Default=2 sec.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..30  

agnVoiceSwConfLidt 1.3.6.1.4.1.164.3.1.2.9.1.1.6
LIDT: Long Inter Digit Timeout used as timer between digits before routing is completed. If no digits were dialed and LIDT expired then the user will get an error tone and the call will be disconnected. 0 = notApplicable Default=15 sec.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..30  

agnVoiceSwConfDialPlan 1.3.6.1.4.1.164.3.1.2.9.1.1.7
This is the Dialing Plan method that will be used in the Voice Switching. Static Dialing Plan - Routing is defined by the current device Zone and Node ID in the Network. Static Dialing Plan Plus - Includes the Static Dialing Plan but contains an addition of defining the number of dialed digits. Flexible Dialing Plan - Routing is defined in a flexible form. In this plan the user can configure the extension number of a local voice channel, Route a call to a remote destination and enter the Number of Digits for a specific dial prefix.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER staticDialPlan(2), staticDialPlanPlus(3), flexDialPlan(4)  

agnVoiceSwConfRtTable 1.3.6.1.4.1.164.3.1.2.9.2
Routing Table for Voice Switching.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnVoiceSwConfRtEntry

agnVoiceSwConfRtEntry 1.3.6.1.4.1.164.3.1.2.9.2.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AgnVoiceSwConfRtEntry  

agnVoiceSwConfRtDbId 1.3.6.1.4.1.164.3.1.2.9.2.1.1
Active or Temporary Table. Both configurations can be read but only the Temporary can be written to.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER active(1), temporary(255)  

agnVoiceSwConfRtIdx 1.3.6.1.4.1.164.3.1.2.9.2.1.2
The Index of the row.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

agnVoiceSwConfRtDigits 1.3.6.1.4.1.164.3.1.2.9.2.1.3
Dialed digits: Series of digits 0...9, '*', '#' or '%'. The '*' and '#' can have many uses according to the user's decision. For example, they can be used as part of the Dialed Number, they exist on the phone number panel. '*' can also be used instead of a series of numbers. The '%' means any digits (wildcard) and is used without a series of digits. When the agnVoiceSwConfRtAction is del (7), the series of digits that are configured via this MIB object will be deleted from the prefix of the dialed number.
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(1..7)  

agnVoiceSwConfRtAction 1.3.6.1.4.1.164.3.1.2.9.2.1.4
Action that the system should perform for the digits: agnVoiceSwConfRtDigits. The action that is allowed depends on the Dialing Plan. Here is the list of the allowed actions: For Static Dialing Plan - zone, node, in, shortDialing, hgr, del, rep For Static Dialing Plan Plus - zone, node, in, shortDialing, hgr, del, rep, numDigDP For Flexible Dialing Plan - hgr, del, rep, numDigDP, route, ext
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER notApplicable(1), zone(2), node(3), shortDialing(4), in(5), hgr(6), del(7), rep(8), pri(9), bri(10), numDigDP(11), route(12), ext(13)  

agnVoiceSwConfRtData 1.3.6.1.4.1.164.3.1.2.9.2.1.5
This field is relevant for actions hgr(6), and rep(8), numDigDP(11) and contains the following information: For hgr - the number of the Hunt Group. For rep - the number of digits to be replaced with. For numDigDP - the number of digits collected before establishing the call. 0 indicates no defined length. In this case SIDT will be used.
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(1..7)  

agnVoiceSwConfRtSlot 1.3.6.1.4.1.164.3.1.2.9.2.1.6
Routing Slot- Relevant for actions zone(2), node(3), shortDialing(4), route(12), ext(13).
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER noConnect(2), cl(3), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

agnVoiceSwConfRtPort 1.3.6.1.4.1.164.3.1.2.9.2.1.7
Routing Port- Relevant for actions zone(2), node(3), shortDialing(4), route(12), ext(13). 100=noConnect (for non-routing case).
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

agnVoiceSwConfRtDlci 1.3.6.1.4.1.164.3.1.2.9.2.1.8
Routing DLCI- Relevant for actions zone(2), node(3), shortDialing(4), route(12), ext(13). Valid values: 0=notApplicable (for non-routing case). 1, 16..991
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

agnVoiceSwConfRtRowStatus 1.3.6.1.4.1.164.3.1.2.9.2.1.9
Status of the row for creating/deleting entries in the table. The only possible supported RowStatus vaules are active (1), notInService (2), notReady(3), createAndGo(4), createAndWait(5) and destroy(6).
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

agnVoiceSwConfRtMaxCalls 1.3.6.1.4.1.164.3.1.2.9.2.1.10
Maximum no. of simultaneous voice calls that are allowed in the direction defined by the current entry. Default=0 (No Limit).
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

agnVoiceSwConfRtPriority 1.3.6.1.4.1.164.3.1.2.9.2.1.11
This attribute indicates a unique priority of the Voice Switching Route. 1 is the lowest priority and 7 is the highest priority. 0 means N/A
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

agnVoiceSwConfHGTable 1.3.6.1.4.1.164.3.1.2.9.5
Table of Hunt Groups.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnVoiceSwConfHGEntry

agnVoiceSwConfHGEntry 1.3.6.1.4.1.164.3.1.2.9.5.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AgnVoiceSwConfHGEntry  

agnVoiceSwConfHGdbIdx 1.3.6.1.4.1.164.3.1.2.9.5.1.1
Active or Temporary Table. Both configurations can be read but only the Temporary can be written to.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER active(1), temporary(255)  

agnVoiceSwConfHGIdx 1.3.6.1.4.1.164.3.1.2.9.5.1.2
For Vmux-300 devices - This object represents a combination of - Hunt Group number and Extension number OR - Port number and Extension number. For other devices (e.g. MXcess, MP-2100H) - There may be up to 10 Hunt Groups per MXcess. That's the index of the hunt group relevant to this row.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

agnVoiceSwConfHGConnect 1.3.6.1.4.1.164.3.1.2.9.5.1.3
This attribute indicates whether the hunt group should be considered in any of the mux algorithms.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

agnVoiceSwConfHGExt 1.3.6.1.4.1.164.3.1.2.9.5.1.4
This is the extension number of the hunt group. 0 is for not valid. The allowed range is 10 - 99.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..99  

agnVoiceSwConfHGExtString 1.3.6.1.4.1.164.3.1.2.9.5.1.5
This is the extension string of the hunt group. This string is a combination of digits, * and #.
Status: current Access: read-write
OBJECT-TYPE    
  SnmpAdminString  

agnVoiceSwConfHGUserParams 1.3.6.1.4.1.164.3.1.2.9.5.1.6
This object indicates the User's parameters.
Status: current Access: read-write
OBJECT-TYPE    
  SnmpAdminString  

agnVoiceSwConfHGStatus 1.3.6.1.4.1.164.3.1.2.9.5.1.7
This object enables the user to create/delete entries in this table. Its usage for values (1)..(6) should be identical to RowStatus SYNTAX. notApplicable(255) - should be used when the table is static (i.e. whenever create/delete entries is not allowed).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER active(1), notInService(2), notReady(3), createAndGo(4), createAndWait(5), destroy(6), notApplicable(255)  

agnSigProfileTable 1.3.6.1.4.1.164.3.1.2.10.1
- For products supporting more than one configuration, the write operation into the Table is valid only to the TmpCnfg entry. - For products that do not support configurations, the write operation into the Table will be to agnSigProfileCnfgIdx=1. The table includes signaling profile parameters for Legacy Profiles.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnSigProfileEntry

agnSigProfileEntry 1.3.6.1.4.1.164.3.1.2.10.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AgnSigProfileEntry  

agnSigProfileCnfgIdx 1.3.6.1.4.1.164.3.1.2.10.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. For products supporting more than one configuration,the write operation is valid only to the TmpCnfg. For Gmux2000 the range limitation (1..255) was discarded since the Idx is computed as: x 1000 + 255.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

agnSigProfileIdx 1.3.6.1.4.1.164.3.1.2.10.1.1.2
This attribute indicates the Signaling Profile (1..5). For MP-104/204, only Profile=1 will exist.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..5  

agnSigProfileRxTx 1.3.6.1.4.1.164.3.1.2.10.1.1.3
This attribute indicates if the following objects refer to: Rx or Tx translation. Rx : ML->IO Tx : IO->ML . For MP-104/204, that means: Rx : Signaling to FXS CH Tx : Signaling to E1 Link.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER rx(1), tx(2)  

agnSigProfileABCD 1.3.6.1.4.1.164.3.1.2.10.1.1.4
For MP-2100/MP-2200 and for MP-104/204 from R2: This object represents 6 parameters, by 3 Octets : Busy Code-MSB nibble, - applicable only for Rx translation Idle Code- nibble, - applicable only for Rx translation D Bit Code- nibble, C Bit Code- nibble, B Bit Code- nibble, A Bit Code-LSB nibble. Each of Busy and Idle Code nibble will have the valid values: 0000 .. FFFF. Each of A,B,C,D Bit Code nibble represents: 0 hex = 0000 = 0 1 hex = 0001 = 1 2 hex = 0010 = A bit 3 hex = 0011 = B bit 4 hex = 0100 = C bit 5 hex = 0101 = D bit 6 hex = 0110 = A bit inverse 7 hex = 0111 = B bit inverse 8 hex = 1000 = C bit inverse 9 hex = 1001 = D bit inverse A-F hex - not used (invalid values) For MP-104/204 R1: This object represents 3 parameters, by 2 Octets : Bit 1 = Bit A - OFF Hook for Tx ; Ring for Rx (LSB) Bit 2 = Bit B - OFF Hook for Tx ; Ring for Rx Bit 3 = Bit C - OFF Hook for Tx ; Ring for Rx Bit 4 = Bit D - OFF Hook for Tx ; Ring for Rx Bit 5 = Bit A - ON Hook for Tx ; Idle for Rx Bit 6 = Bit B - ON Hook for Tx ; Idle for Rx Bit 7 = Bit C - ON Hook for Tx ; Idle for Rx Bit 8 = Bit D - ON Hook for Tx ; Idle for Rx Bit 9 = Bit A - OOS State for both Tx and Rx Bit 10 = Bit B - OOS State for both Tx and Rx Bit 11 = Bit C - OOS State for both Tx and Rx Bit 12 = Bit D - OOS State for both Tx and Rx Bit 13 = Spare (always 0) Bit 14 = Spare (always 0) Bit 15 = Spare (always 0) Bit 16 = Spare (always 0) (MSB) When the object is not applicable, the Octet String will have 0 bytes.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

agnSigProfTable 1.3.6.1.4.1.164.3.1.2.10.2
The write operation into the Table Objects is valid only to the TmpCnfg entry. This is the general table of signaling profiles.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgnSigProfEntry

agnSigProfEntry 1.3.6.1.4.1.164.3.1.2.10.2.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AgnSigProfEntry  

agnSigProfCnfgIdx 1.3.6.1.4.1.164.3.1.2.10.2.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. The write operation is valid only to the TmpCnfg.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

agnSigProfIdx 1.3.6.1.4.1.164.3.1.2.10.2.1.2
This attribute indicates the Signaling Profile (1..5).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..5  

agnSigProfName 1.3.6.1.4.1.164.3.1.2.10.2.1.3
Profile Name given by user.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..12)  

agnSigProfType 1.3.6.1.4.1.164.3.1.2.10.2.1.4
Profile Type. legacy - usual signaling. The parameters for the Legacy Profiles are detailed in the agnSigProfileTable, above. r2Cas - R2 signaling. The parameters for the R2 Profiles are detailed in the r2 ProfileCnfg tables (belong to r2If).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), legacy(2), r2Cas(3)  

systemVoiceTable 1.3.6.1.4.1.164.3.1.2.12.1
General Parameters for voice - system level.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SystemVoiceEntry

systemVoiceEntry 1.3.6.1.4.1.164.3.1.2.12.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SystemVoiceEntry  

systemVoiceConfIdx 1.3.6.1.4.1.164.3.1.2.12.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed - Active or Temporary Configurations. Idx 255 relates to the temporary TmpCnfg. All configurations can be read but only the Temporary can be written to.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

systemVoiceNationalTone 1.3.6.1.4.1.164.3.1.2.12.1.1.2
Tone Characteristics (Amplitude, Frequency, delays etc.). These characteristics are defined according to the country.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), usa(2), australia(3), brazil(4), canada(5), france(6), germany(7), israel(8), mexico(9), portugal(10), russia(11), spain(12), unitedKingdom(13), czech(14), china(15)  

systemVoicePacketRate 1.3.6.1.4.1.164.3.1.2.12.1.1.3
This object indicates the G.729 and G.711 Coders transmitted Packet Rate in milliseconds.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

systemVoiceFaxSupport 1.3.6.1.4.1.164.3.1.2.12.1.1.4
This object allows the user to Disable/Enable Fax support.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), faxRelayT38(3), vbdPassThrou(4)  

systemVoiceFaxRate 1.3.6.1.4.1.164.3.1.2.12.1.1.5
This object indicates the Fax Rate limit. It is irrelevant when Fax support is NA or disabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notConnected(1), r4800bps(2), r9600bps(4), r14400bps(6)  

systemVoiceModemSupport 1.3.6.1.4.1.164.3.1.2.12.1.1.6
This object allows the user to Disable/Enable Modem support.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), vbdV152(3), vbdPassThrou(4)  

systemVoiceCoderAndRate 1.3.6.1.4.1.164.3.1.2.12.1.1.7
This object indicates the Coder and Rate for the Voice Compression.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), g711aLAW(5), g711uLAW(6)  

systemVoiceEchoCanceler 1.3.6.1.4.1.164.3.1.2.12.1.1.8
This object indicates the Echo Canceler activation.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

systemVoiceTxGain 1.3.6.1.4.1.164.3.1.2.12.1.1.9
This object indicates the Transmit Gain (volume) in dB.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

systemVoiceDtmfRelayMethod 1.3.6.1.4.1.164.3.1.2.12.1.1.10
This object indicates the DTMF Relay Method that is used to transmit DTMF tones. rfc2833(1) - inband DTMF relay according to RFC-2833. sipInfo(2) - out of band DTMF relay using SIP INFO method.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER rfc2833(1), sipInfo(2)  

systemVoiceDtmfRelayRxPayloadType 1.3.6.1.4.1.164.3.1.2.12.1.1.11
This object indicates the Rx Payload Type for DTMF relay RTP packets. It is relevant only when DTMF Relay Method is RFC-2833.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

systemVoiceDtmfRelayPayloadTypeNeg 1.3.6.1.4.1.164.3.1.2.12.1.1.12
This object indicates whether Payload Type Negotiation is used (according to RFC-2833) or not. It is relevant only when DTMF Relay Method is RFC-2833.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

systemVoiceDtmfRelayTxPayloadType 1.3.6.1.4.1.164.3.1.2.12.1.1.13
This object indicates the Tx Payload Type for DTMF relay RTP packets. It is relevant only when the Payload Type Negotiation is disabled.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

systemVoiceCoderTable 1.3.6.1.4.1.164.3.1.2.12.2
Voice Coders table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SystemVoiceCoderEntry

systemVoiceCoderEntry 1.3.6.1.4.1.164.3.1.2.12.2.1
An entry in Voice Coders table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SystemVoiceCoderEntry  

systemVoiceCoderConfIdx 1.3.6.1.4.1.164.3.1.2.12.2.1.1
The first index of the table. This object might represent the Configuration Index (1..100) being accessed; Index=255 relates to the TmpCnfg. For devices with multiple configurations, Set is permitted to TmpCnfg(255) only. Not-Applicable = 1.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

systemVoiceCoderPriority 1.3.6.1.4.1.164.3.1.2.12.2.1.2
This object indicates the Coder's Priority.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

systemVoiceCoderCoderAndRate 1.3.6.1.4.1.164.3.1.2.12.2.1.3
This object indicates the Coder and Rate for the Voice Compression.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), g7231r6300BPS(2), g7231r5300BPS(3), g729A8KBPS(4), g711aLAW(5), g711uLAW(6), none(255)  

mdlSInstTable 1.3.6.1.4.1.164.3.1.3.1.1
A table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MdlSInstEntry

mdlSInstEntry 1.3.6.1.4.1.164.3.1.3.1.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  MdlSInstEntry  

mdlSInstSltIdx 1.3.6.1.4.1.164.3.1.3.1.1.1.1
A unique number to identify a slot position in the mux. In the ?004 Unit the entries PsB(2),ClB(4),io6(10)..io(16) are not valid. For the Vmux2100 Main Board clA (3) is used.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER psA(1), psB(2), clA(3), clB(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

mdlSInstCardType 1.3.6.1.4.1.164.3.1.3.1.1.1.2
This attribute indicates the type of card installed in the specific slot position. Only PS cards are possible in the PS slots. Only CL cards are possible in the CL slots. Only IO cards are possible in the IO slots.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), empty(2), acm(9), ps60W(10), ps100W(11), ps(17), cl1(20), clEth(21), cl2(22), cl2Eth(23), cl3(24), cl3Eth(25), cl1Clk(26), mPh1(31), mPh3(32), mPh1T1DSU(33), mPh1T1CSU(34), mPh1E1DSU(35), mPh1E1LTU(36), mtmlFT1(37), mtmlFE1(38), mtmlH4E1(39), mtmlH4E12W(40), mtmlH4T1(41), mtmlH4T12W(42), mtHsh4E1(43), mtHsh4E12W(44), mtHsh4T1(45), mtHsh4T12W(46), mtmlH2E1(47), mtmlH2E12W(48), mtmlH2T1(49), mtmlH2T12W(50), hsh2E1(51), hsh2E12W(52), hsh2T1(53), hsh2T12W(54), mlIp(55), mtml4Ip(56), ml20N1(57), ml20N2(58), mPl6(60), mPl3(61), vf24T1(62), vf30E1(63), vf48T1(64), vf60E1(65), ml2E1(68), ml4E1(69), ml2T1(70), ml4T1(71), mPv4(72), vc16A(73), vc8EandM(74), vc8Fxo(75), vc8Fxs(76), vc16EandM(77), vc16Fxo(78), vc16Fxs(79), vf3EandM(80), vf3Fxs(81), vf3Fxo(82), vfPbx(83), vfPbxT1(84), vfPbxE1(85), mtMlE2S(86), mtMlE2D(87), mtMlF2T1(88), mtMlF2E1(89), mtMlT1Fiber(90), mtMlE1Fiber(91), mtMlT1FiberFb(92), mtMlE1FiberFb(93), mtmlHE1(94), mtmlH1E1(95), mtmlHSE1(96), ml20(97), mtMl4T1(98), mtMl4E1(99), mtMl1T1DSU(100), mtMl1T1CSU(101), mtMl1E1DSU(102), mtMl1E1LTU(103), mtMl1T1DSUfb(104), mtMl1T1CSUfb(105), mtMl1E1DSUfb(106), mtMl1E1LTUfb(107), mtMl2T1(108), mtMl2E1(109), ls2CcittX50(110), ls2CcittX58(111), ls2ATandTSdm(112), ls2ACcittX50(113), ls2ACcittX58(114), ls2AATandTSdm(115), ls2A2Ts(116), ls2M(117), mtMlT1(118), mtMlE1(119), hs2(120), hs3(121), hsq(122), hs703(123), hsQM(124), hsqN(125), hs6(126), hs12(127), hsDp(128), hsp(129), hs4T1(130), hs4E1(131), hs4(132), hsEth(133), ml8T1(134), ml8E1(135), vc2E1(136), vc4E1(137), vc2T1(138), vc4T1(139), vc2EandM(140), vc2Fxs1Plar(141), vc2Fxo1(142), vc2Fxs2(143), vc2Fxo2(144), vc2Fxs3(145), vc2Fxo3(146), vc26EandM(147), mtvc2(148), vc2R2Fxs(149), hsu(150), mbeA(151), mbeB(152), mbeU(153), tre(154), hsuI(155), hsr(156), hss(157), hsu1(158), ls12(159), ls6(160), ls6V1EandM(161), ls6V1Fxo(162), ls6V1Fxs(163), ls6V2EandM(164), ls6V2Fxo(165), ls6V2Fxs(166), ls6VfEandM(167), ls6VfFxo(168), ls6VfFxs(169), vc3EandM(170), vc3Fxo(171), vc3Fxs(172), vcPbx(173), vcPbxT1(174), vcPbxE1(175), vc6EandM(176), vc6Fxo(177), vc6Fxs(178), vcq(179), ls6n(180), mhs1V36(181), mhs1V35(182), mhs1G703(183), mhs1DDS(184), mhs3(185), mhs1X21(186), mhs1V24(187), mhs4(188), mhsE1Hs(189), mhsT1Hs(190), mhsHyE1Hs(191), mhsHyT1Hs(192), mlfHybE1Hs(193), mlfHybT1Hs(194), mhs2e1(195), mhs2t1(196), mhsHy2e1(197), mhsHy2t1(198), mlfHybE12(199), mls6(200), mls3(201), mlHybAtmE1(202), mlHybAtmT1(203), mlfHybT12(204), mvc8(205), mvc8PbxE1(206), mvc8PbxT1Dsu(207), mvc8PbxT1Csu(208), mvc8PbxE1Slave(209), mvc4(210), mvc4PbxE1(211), mvc4PbxT1Dsu(212), mvc4PbxT1Csu(213), mvc4PbxE1Slave(214), mvc4PbxT1Slave(215), mvc8PbxT1Slave(216), mvc8ExtAnalog(217), mvcE1(218), mvcT1(219), mhsS(220), mhsU(221), mhsPriE1(222), mhsPriT1(223), hsEthSwitch(224), mPriE1FramerCcs(225), mPriT1FramerCcs(226), mPriE1SlaveCcs(227), mPriT1SlaveCcs(228), mDualBri(229), vc12EandM(230), vc12Fxo(231), vc12Fxs(232), vc6aEandM(233), vc6aFxo(234), vc6aFxs(235), vc6AgFxo(236), vc6AgFxs(237), vc6a4LB(238), vid(239), hsu12(240), hsu6(241), hss12(242), hss6(243), hsDp3(244), hsDp6(245), hsf1(246), mhsHyE1(247), mhsHyT1(248), mhsIp(249), mlIpHs(250), mlHybIpE1(251), mlHybIpT1(252), mvg1Lan(253), mvg2Lan(254), vc4Fxs(255), vc4EandM(256), vc4Fxo(257), hsf2(258), mvgSwitch4Lan(260), msl4E1W2(261), msl4E1W4(262), msl8E1W2(263), msl4E1W2Eth(264), msl8E1W2Eth(265), asmi54cE1AndEth(266), asmi54cT1AndEth(267), hs6N(271), hs12N(272), hsNRZ(273), evc2E1(281), evc4E1(282), evc2T1(283), evc4T1(284), vc2E1Pri(285), vc4E1Pri(286), vc4OmniEandM(291), vc4OmniWestern(292), clx1(301), clx1GbE(302), clx1S155(303), clx1S155GbE(304), ml8T1Eth(305), ml8E1Eth(306), op106cEth(307), op108cEth(308), op106cEthT1(309), op108cEthE1(310), op108cEthE1Unbal(311), mpw1(312), vfs24T1(321), vfs30E1(322), vfs48T1(323), vfs60E1(324), mm4E1(325), mm4T1(326), mm8E1(327), mm8T1(328), mm12E1(329), mm12T1(330), mm16E1(331), mm16T1(332)  

mdlSHwVersion 1.3.6.1.4.1.164.3.1.3.1.1.1.3
This attribute indicates the Hardware version of the installed card in the specific slot position.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

mdlSSwVersion 1.3.6.1.4.1.164.3.1.3.1.1.1.4
This attribute indicates the Software version of the installed card in the specific slot position.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

mdlSAlrStatus 1.3.6.1.4.1.164.3.1.3.1.1.1.5
Indicates the alarm state at module level, i.e. lower level (port alarms) status is not included. This attribute will be set to: critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(2), event(3), minor(4), major(5), warning(6), critical(7)  

mdlSAlrStatusAll 1.3.6.1.4.1.164.3.1.3.1.1.1.6
Indicates the alarm state in the module-all level, i.e. lower level (port alarms) included. This attribute will be set to: critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(2), event(3), minor(4), major(5), warning(6), critical(7)  

mdlSMaskedAlrStat 1.3.6.1.4.1.164.3.1.3.1.1.1.7
Indicates the alarm state at module level, [i.e. lower level (port alarms) status is not included],including Masked alarms. This attribute will be set to: critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(2), event(3), minor(4), major(5), warning(6), critical(7)  

mdlSMaskedAlrStatAll 1.3.6.1.4.1.164.3.1.3.1.1.1.8
Indicates the alarm state in the module-all level, i.e. lower level (port alarms) included, including Masked alarms. This attribute will be set to: critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(2), event(3), minor(4), major(5), warning(6), critical(7)  

mdlSTstStatusAll 1.3.6.1.4.1.164.3.1.3.1.1.1.9
This attribute will be set to on(3) when there is at least one test in progress on a channel of the card, otherwise the value will be off(2).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(2), on(3)  

mdlSClearAlrCmd 1.3.6.1.4.1.164.3.1.3.1.1.1.10
Setting this command to ON, enforces a clear of all the alarms in the given slot, excluding alarms of port level. The clear operation will not be applied for masked/inverted alarms.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

mdlSClearAllAlrCmd 1.3.6.1.4.1.164.3.1.3.1.1.1.11
Setting this command to ON, enforces a clear of all the alarms in the given slot, including all its ports alarms. The clear operation will not be applied for masked/inverted alarms.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

mdlSTemperature 1.3.6.1.4.1.164.3.1.3.1.1.1.12
Temperature of the card, in Celsius degrees.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

mdlSAlrTable 1.3.6.1.4.1.164.3.1.3.1.2
The list of card agent alarms ; includes also an alarm indicating existence of alarms on its ports if there are any.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MdlSAlrEntry

mdlSAlrEntry 1.3.6.1.4.1.164.3.1.3.1.2.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  MdlSAlrEntry  

mdlSAlrIdx 1.3.6.1.4.1.164.3.1.3.1.2.1.1
A unique number to identify an entry in the alarm status table. Users should use the get next function to read this table because the indexes are not consecutive.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

mdlSAlrSltIdx 1.3.6.1.4.1.164.3.1.3.1.2.1.2
This attribute indicates the desired slot position. In the ?004 Unit the entries PsB(2),ClB(4),io6(10)..io12(16) are not valid. For the Vmux2100 Main Board clA (3) is used.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER psA(1), psB(2), clA(3), clB(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

mdlSAlrCodeDescription 1.3.6.1.4.1.164.3.1.3.1.2.1.3
This attribute is a full text description of the alarm . The alarm description includes the following information: alarm code, alarm text, alarm severity, Masked or Inverted flag and counter.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

mdlSAlrCode 1.3.6.1.4.1.164.3.1.3.1.2.1.4
A code identifying the alarm of an entry in the alarm status table at card level.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

mdlSAlrSeverity 1.3.6.1.4.1.164.3.1.3.1.2.1.5
The severity of the alarm.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER event(3), minor(4), major(5), warning(6), critical(7)  

mdlSAlrState 1.3.6.1.4.1.164.3.1.3.1.2.1.6
State of the alarm.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(2), on(3)  

mdlSAlrCounter 1.3.6.1.4.1.164.3.1.3.1.2.1.7
A counter - how many times the alarm occured since last clear operation. ON and OFF Alarm will be counted separately.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

mdlSAlrMask 1.3.6.1.4.1.164.3.1.3.1.2.1.8
Alarm mask : on/off.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(2), on(3)  

mdlSAlrInvert 1.3.6.1.4.1.164.3.1.3.1.2.1.9
Alarm invert : on/off.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(2), on(3)  

mdlCPrgTable 1.3.6.1.4.1.164.3.1.3.2.1
A table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MdlCPrgEntry

mdlCPrgEntry 1.3.6.1.4.1.164.3.1.3.2.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  MdlCPrgEntry  

mdlCCnfgIdx 1.3.6.1.4.1.164.3.1.3.2.1.1.1
This attribute indicates the Idx of the Cnfg(1..100) being referred. Value 255 specifies the TmpCnfg
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

mdlCSltIdx 1.3.6.1.4.1.164.3.1.3.2.1.1.2
This attribute indicates a unique number of the slot position where the card is inserted. In the ?004 Unit the entries psB(2),clB(4),io6(10)..io(16) are not valid.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER psA(1), psB(2), clA(3), clB(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

mdlCPrgCardType 1.3.6.1.4.1.164.3.1.3.2.1.1.3
This attribute indicates the type of card assigned to the specific slot in the common configuration. This object is identical in all the configurations (1..100). Only the TmpCnf(255) may have different value. The write operation is valid only to the TmpCnfg entry.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), empty(2), acm(9), ps48x60W(10), ps48x100W(11), ps110x60W(12), ps110x100W(13), ps220x60W(14), ps220x100W(15), ps180W(16), ps(17), cl1(20), clEth(21), cl2(22), cl2Eth(23), cl3(24), cl3Eth(25), cl1Clk(26), mPh1(31), mPh3(32), mPh1T1DSU(33), mPh1T1CSU(34), mPh1E1DSU(35), mPh1E1LTU(36), mtmlFT1(37), mtmlFE1(38), mtmlH4E1(39), mtmlH4E12W(40), mtmlH4T1(41), mtmlH4T12W(42), mtHsh4E1(43), mtHsh4E12W(44), mtHsh4T1(45), mtHsh4T12W(46), mtmlH2E1(47), mtmlH2E12W(48), mtmlH2T1(49), mtmlH2T12W(50), hsh2E1(51), hsh2E12W(52), hsh2T1(53), hsh2T12W(54), mlIp(55), mtml4Ip(56), ml20N1(57), ml20N2(58), mPl6(60), vf24T1(62), vf30E1(63), vf48T1(64), vf60E1(65), ml2E1(68), ml4E1(69), ml2T1(70), ml4T1(71), vc16A(73), vc8EandM(74), vc8Fxo(75), vc8Fxs(76), vc16EandM(77), vc16Fxo(78), vc16Fxs(79), vf3EandM(80), vf3Fxs(81), vf3Fxo(82), vfPbx(83), vfPbxT1(84), vfPbxE1(85), mtMlE2S(86), mtMlE2D(87), mtMlF2T1(88), mtMlF2E1(89), mtMlT1Fiber(90), mtMlE1Fiber(91), mtMlT1FiberFb(92), mtMlE1FiberFb(93), mtmlHE1(94), mtmlH1E1(95), mtmlHSE1(96), ml20(97), mtMl4T1(98), mtMl4E1(99), mtMl1T1DSU(100), mtMl1T1CSU(101), mtMl1E1DSU(102), mtMl1E1LTU(103), mtMl1T1DSUfb(104), mtMl1T1CSUfb(105), mtMl1E1DSUfb(106), mtMl1E1LTUfb(107), mtMl2T1(108), mtMl2E1(109), ls2CcittX50(110), ls2CcittX58(111), ls2ATandTSdm(112), ls2ACcittX50(113), ls2ACcittX58(114), ls2AATandTSdm(115), ls2A2Ts(116), ls2M(117), mtMlT1(118), mtMlE1(119), hs2(120), hs3(121), hsq(122), hs703(123), hsQM(124), hsqN(125), hs6(126), hs12(127), hsDp(128), hsp(129), hs4T1(130), hs4E1(131), hsEth(133), ml8T1(134), ml8E1(135), vc2E1(136), vc4E1(137), vc2T1(138), vc4T1(139), vc2EandM(140), vc2Fxs1Plar(141), vc2Fxo1(142), vc2Fxs2(143), vc2Fxo2(144), vc2Fxs3(145), vc2Fxo3(146), vc26EandM(147), mtvc2(148), vc2R2Fxs(149), hsu(150), mbeA(151), mbeB(152), mbeU(153), tre(154), hsuI(155), hsr(156), hss(157), hsu1(158), ls12(159), ls6(160), ls6V1EandM(161), ls6V1Fxo(162), ls6V1Fxs(163), ls6V2EandM(164), ls6V2Fxo(165), ls6V2Fxs(166), ls6VfEandM(167), ls6VfFxo(168), ls6VfFxs(169), vc3EandM(170), vc3Fxo(171), vc3Fxs(172), vcPbx(173), vcPbxT1(174), vcPbxE1(175), vc6EandM(176), vc6Fxo(177), vc6Fxs(178), vcq(179), ls6n(180), mhs1V36(181), mhs1V35(182), mhs1G703(183), mhs1DDS(184), mhs3(185), mhs1X21(186), mhs1V24(187), mhs4(188), mhsE1Hs(189), mhsT1Hs(190), mhsHyE1Hs(191), mhsHyT1Hs(192), mlfHybE1Hs(193), mlfHybT1Hs(194), mhs2e1(195), mhs2t1(196), mhsHy2e1(197), mhsHy2t1(198), mlfHybE12(199), mls6(200), mls3(201), mlHybAtmE1(202), mlHybAtmT1(203), mlfHybT12(204), mvc8(205), mvc8PbxE1(206), mvc8PbxT1Dsu(207), mvc8PbxT1Csu(208), mvc8PbxE1Slave(209), mvc4(210), mvc4PbxE1(211), mvc4PbxT1Dsu(212), mvc4PbxT1Csu(213), mvc4PbxE1Slave(214), mvc4PbxT1Slave(215), mvc8PbxT1Slave(216), mvc8ExtAnalog(217), mvcE1(218), mvcT1(219), mhsS(220), mhsU(221), mhsPriE1(222), mhsPriT1(223), hsEthSwitch(224), mPriE1FramerCcs(225), mPriT1FramerCcs(226), mpriE1SlaveCcs(227), mpriT1SlaveCcs(228), mDualBri(229), vc12EandM(230), vc12Fxo(231), vc12Fxs(232), vc6aEandM(233), vc6aFxo(234), vc6aFxs(235), vc6AgFxo(236), vc6AgFxs(237), vc6a4LB(238), vid(239), hsu12(240), hsu6(241), hss12(242), hss6(243), hsDp3(244), hsDp6(245), hsf1(246), mhsHyE1(247), mhsHyT1(248), mhsIp(249), mlIpHs(250), mlHybIpE1(251), mlHybIpT1(252), mvg1Lan(253), mvg2Lan(254), vc4Fxs(255), vc4EandM(256), vc4Fxo(257), hsf2(258), mvgSwitch4Lan(260), msl4E1W2(261), msl4E1W4(262), msl8E1W2(263), msl4E1W2Eth(264), msl8E1W2Eth(265), asmi54cE1AndEth(266), asmi54cT1AndEth(267), hs6N(271), hs12N(272), hsNRZ(273), evc2E1(281), evc4E1(282), evc2T1(283), evc4T1(284), vc2E1Pri(285), vc4E1Pri(286), vc4OmniEandM(291), vc4OmniWestern(292), clx1(301), clx1GbE(302), clx1S155(303), clx1S155GbE(304), ml8T1Eth(305), ml8E1Eth(306), op106cEth(307), op108cEth(308), op106cEthT1(309), op108cEthE1(310), op108cEthE1Unbal(311), mpw1(312), vfs24T1(321), vfs30E1(322), vfs48T1(323), vfs60E1(324)  

mdlCNoOfExternPrt 1.3.6.1.4.1.164.3.1.3.2.1.1.4
Number of external ports in the programmed card of the specific slot position
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

mdlCNoOfInternPrt 1.3.6.1.4.1.164.3.1.3.2.1.1.5
Number of internal ports in the programmed card of the specific slot position.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

mdlCWorkMode 1.3.6.1.4.1.164.3.1.3.2.1.1.6
Working mode of the card. The user may configure the card to work in a stand alone mode or integrated with the device. Example for use in MHS-IP cards: - standAlone - in this mode, the router works so that data is received via the LAN (Eth) port and is transmitted via the WAN (HS) external port without going through the MPH device. - integrated - in this mode, the router works so that it is integrated in the MPH and routes DLCIs into the device.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), standAlone(2), integrated(3)  

mdlCDhcpClientEnable 1.3.6.1.4.1.164.3.1.3.2.1.1.7
Enable/Disable the feature of DHCP Client for the selected card.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

mdlCRdnExists 1.3.6.1.4.1.164.3.1.3.2.1.1.8
This object indicates whether any port of the programmed card is configured to be part of a Redundancy/APS pair. If at least one port of the programmed card is configured to be part of a Redundancy/APS pair, the value will be 'yes'. Otherwise, it will be 'no'.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

mdlCInterfaces 1.3.6.1.4.1.164.3.1.3.2.1.1.9
Octet string which indicates 'present' interfaces in card. Each '0' bit stands for non-present interface. Each '1' bit stands for present interface. For ASMi54C card of LRS-102 and MP-4100 notPresent interfaces may be: - SHDSL Line ID with no wire pairs assigned to it (does not exist in ifTable) - PCS without SHDSL Line binded to it, (exist in ifTable, with ifOperStatus= notPresent) - External DS1 when its LIU is used by an Internal DS1 of the same card - Internal DS1 when single bearer is not TDM. In each octet, MS bit represents port 1 and LS bit represents port 8 MSB LSB 1 0 0 0 1 0 0 0 -- Example: Port # 1 and 5 are present. Port 1 2 3 4 5 6 7 8 1st Octet (MSB octet) represents SDHSL Lines 2nd Octet represents PCS 3rd Octet represents External DS1 4th Octet represents Internal DS1 5th and 6th Octets are reserved for future Internal DS1. For OP-108/106 cards of LRS-102 and MP-4100 notPresent interfaces may be: - External DS1 when its 'associated' Int-DS1 port is connected to another card - Internal DS1 when its 'associated' Ext-DS1 port is connected to another card (Both may be 'present' when inter-connected). 1st Octet represents External DS1 2nd Octet represents Internal DS1 Bit representation, same as for ASMi-54C card.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

mdlCmprTable 1.3.6.1.4.1.164.3.1.3.3.1
A table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MdlCmprEntry

mdlCmprEntry 1.3.6.1.4.1.164.3.1.3.3.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  MdlCmprEntry  

mdlCmprTypIdx 1.3.6.1.4.1.164.3.1.3.3.1.1.1
This attribute indicates the Type of the Compressed being referred.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

mdlCmprCnfgIdx 1.3.6.1.4.1.164.3.1.3.3.1.1.2
This attribute indicates the configuration to which the Compressed information is related.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

mdlCmprVersion 1.3.6.1.4.1.164.3.1.3.3.1.1.3
This attribute indicates the version of the internal format of the Compressed data
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

mdlCmprSltIdx 1.3.6.1.4.1.164.3.1.3.3.1.1.4
This attribute indicates a unique number of the slot position where the card is inserted. In the ?004 Unit the entries psB(2),clB(4),io6(10)..io(16) are not valid.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER psA(1), psB(2), clA(3), clB(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

mdlCmprObj 1.3.6.1.4.1.164.3.1.3.3.1.1.5
This attribute is the compressed information itself.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

mdlAlarmsCmprTable 1.3.6.1.4.1.164.3.1.3.3.2
A table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MdlAlarmsCmprEntry

mdlAlarmsCmprEntry 1.3.6.1.4.1.164.3.1.3.3.2.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  MdlAlarmsCmprEntry  

mdlAlarmsCmprVersion 1.3.6.1.4.1.164.3.1.3.3.2.1.1
This attribute indicates the version of the internal format of the Compressed data
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

mdlAlarmsCmprAlarmSlot 1.3.6.1.4.1.164.3.1.3.3.2.1.2
This attribute indicates the desired slot position. In the ?004 Unit the entries PsB(2),ClB(4),io6(10)..io(16) are not valid.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

mdlAlarmsCmprAlarmIdx 1.3.6.1.4.1.164.3.1.3.3.2.1.3
A unique number to identify an entry in the alarm status table of the agent.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

mdlAlarmsCmprObj 1.3.6.1.4.1.164.3.1.3.3.2.1.4
This attribute is the compressed information itself.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

prtSInstTable 1.3.6.1.4.1.164.3.1.4.1.1
A table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtSInstEntry

prtSInstEntry 1.3.6.1.4.1.164.3.1.4.1.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtSInstEntry  

prtSInstSltIdx 1.3.6.1.4.1.164.3.1.4.1.1.1.1
This attribute indicates a unique number to identify the slot where the card is inserted. In the ?004 Unit the entries io6(10)..io(16) are not valid. For the Vmux2100 Main Board clA (3) is used.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER clA(3), clB(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtSInstPrtIdx 1.3.6.1.4.1.164.3.1.4.1.1.1.2
This attribute indicates a unique number to identify a port in a specific card. The valid ports depend on the installed card: the valid external ports (interfaces) are (1..mdlCNoOfExternPrt) if any, and the valid internal ports are (101..100+mdlCNoOfInternPrt) if any. Generally, for MP-2100/2200: exPrt1 (1) .. exPrt16 (16),inPrt1(101) .. inPrt48 (148) For the Vmux-2100 device: This index will have values of 1...4 for the physical ports & values of ifIndex for the bundles. For other products, see product's spec.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtSInstPrtType 1.3.6.1.4.1.164.3.1.4.1.1.1.3
This attribute describes the type of the designated port. In MX 3000 only external & internal options are used. All the other options are only for MX 30/300 which need special handling. In order to support interface types in MX 3000, return an ascii string for prtSInterfaceType in this table or support the general RAD value of physicalConnector. External port - is a port with a physical connector. Internal port - might be of two types: a) A composite port which collects a few external ports data into a common bandwidth (usually routed through DS1 link) b) A port which gets only part of the external ports (usually a few DS0's) The following types are used when all ports are external/ internal and the connector/interface type is necessary (for example, stand-alone units): High Speed port types Low Speed port types Voice port types, CL port types. ISDN Voice in MX 30/300 Phase 4: voiceS0 (16), voiceU (17) should be used. ISDN Voice in MX 30/300 Phase 5: voiceQsigS(18), voiceQsigU (19) should be used.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER external(2), internal(3), highSpeedV35(4), highSpeedV24(5), highSpeedV36(6), highSpeedX21(7), highSpeedG703(8), highSpeedDDS(9), lowSpeed(10), voice(11), cl(12), isdns(13), isdnu(14), ethernet(15), voiceS0(16), voiceU(17), voiceQsigS(18), voiceQsigU(19)  

prtSInstIfIndex 1.3.6.1.4.1.164.3.1.4.1.1.1.4
This attribute indicates the unique interface number assigned to the port. The specific interface of this attribute is the same as the interface identified by the value of ifindex in MIB-II.If there is no interface for the specific prtIdx the value will be '7fffffff'h.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtSActiveStatus 1.3.6.1.4.1.164.3.1.4.1.1.1.5
This attribute describes the activity status of the port. unknown(1) indicates that the information is not supported. notUsed(2) indicates that the ch is not connected according to the active config. offLine(3) indicates that the ch is down (not working) because of any problem. onLine(4) indicates that the ch is up (working) offLineRedundancy(5) indicates that the ch is down, because it is redundant port. onLineRedundancy(6) indicates that the ch is up, and it is the active link
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), notUsed(2), offLine(3), onLine(4), offLineRedundancy(5), onLineRedundancy(6)  

prtSAlrStatus 1.3.6.1.4.1.164.3.1.4.1.1.1.6
Indicates the alarm state in the port(ch) agent level. This attribute will be set to: critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(2), event(3), minor(4), major(5), warning(6), critical(7)  

prtSMaskedAlrStat 1.3.6.1.4.1.164.3.1.4.1.1.1.7
Indicates the alarm state in the port(ch) agent level, including Masked alarms. This attribute will be set to: critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(2), event(3), minor(4), major(5), warning(6), critical(7)  

prtSClearAlrCmd 1.3.6.1.4.1.164.3.1.4.1.1.1.8
Setting this attribute to on(3) enforces a clear operation of the alarm status events in the given port. The clear operation will not be applied for masked/inverted alarms.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtSTestMask 1.3.6.1.4.1.164.3.1.4.1.1.1.9
This is a mask which indicates which tests from the 'prtSTstCmd' list are allowed for the requested port. If a specific test is allowed, its respective bit will be SET in the mask : TEST BIT ----------- --- local-loop 1 remote-loop 2 loc-and-rem-main-loops 3 remote-analog-loop 4 remote-digital-loop 5 rem-loop-on-ext-unit 6 bert 7 tone-injection 8 dlci local-loop 9 all dlci local-loop 10 dlci remote-loop 11 all dlci remote-loop 12 bert-and-rem-loop-on-rem-unit 13 rem-loop-on-rem-unit 14 block 15 backward-tone-inject 16 llb 17 rlb 18 ft1Enable 21 lbbd 22 --for 2B+D lb1 23 --for B1 lb2 24 --for B2 llb-on-rem-unit 25 bert-on-rem-unit 26 bert-on-rem-and-llb-on-rem-unit 27 local-and-bert-on-rem-unit 28 local-loop-on-rem-unit 29 localBert 30 --towards IO ports test-per-TS 31 e.g : If the return value is 3 -> 0000000000000011 -> Bits 1 & 2 are set -> the allowed tests are : local-loop remote-loop
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtSTstCmd 1.3.6.1.4.1.164.3.1.4.1.1.1.10
Setting this attribute to any of the above values will initiate a test on the specific port if the operation is legal. If the operation is not legal, the mux will ignore the operation. testPerTS(31) - when this test is selected, the selection of tests for each TS is done via the prtExPh1MlTsTest object. If a test time out is needed, the test will be set with a default timeout of 2 minutes until the user will set the parameter 'prtSTstDuration' to the required time out. If no time out is needed , the test will be set with infinite timeout until the user will set the parameter 'prtSTstDuration' to the required time out.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), localLoop(2), remoteLoop(3), locAndRemMainLoops(4), remoteAnalogLoop(5), remoteDigitalLoop(6), remLoopOnExtUnit(7), bert(8), toneInjection(9), dlciLocalLoop(10), allDlciLocalLoop(11), dlciRemoteLoop(12), allDlciRemoteLoop(13), extInitLocalLoop(14), bertAndRemLoopOnRemUnit(15), remLoopOnRemUnit(16), block(17), backwardToneInject(18), llb(19), rlb(20), ft1Enable(21), lbbd(22), lb1(23), lb2(24), llbOnRemUnit(25), bertOnRemUnit(26), bertOnRemAndLlbOnRemUnit(27), localAndBertOnRemUnit(28), localLoopOnRemUnit(29), localBert(30), testPerTS(31), csuLoopAndBert(32), dsuLoopAndBert(33), remoteOcuLoopAndBert(34), remoteCsuLoopAndBert(35), remoteDsuLoopAndBert(36)  

prtSTstDuration 1.3.6.1.4.1.164.3.1.4.1.1.1.11
This attribute indicates the maximum duration of executing a test on the specific port. This entry applies to all the test operations. The resolution will be a minute, and the maximum duration is limited to 30 minutes. For Vmux devices, the values are in seconds. A zero value specifies no time limitation. When the test isn't active, the agent initiates this object to 2 when the duration is needed and to 0 if its not required. The user should set this parameter after setting the 'prtSTstCmd' parameter.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtSBertClrCmd 1.3.6.1.4.1.164.3.1.4.1.1.1.12
Setting this attribute initiates bert count clear operation. It is valid only when bert test is active on the specific port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtSBertTstRslt 1.3.6.1.4.1.164.3.1.4.1.1.1.13
This attribute indicates the number of Bit Error Rate indicated during the BERT operation. It is valid only when bert test is active on the specific port.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtSInterfaceType 1.3.6.1.4.1.164.3.1.4.1.1.1.14
This attribute indicates a unique HW interface type of the selected port.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

prtSParamStatus 1.3.6.1.4.1.164.3.1.4.1.1.1.15
This object indicates Status of parameters specific to the selected port. - For a port that has no special status or is supported by prtSExHsfStatTable - 1 Octet: 00hex - For VC-6, VC-6A, VC-6AG, VC-6A/4LB, VC-12, VC-12/6, external ports - 1 Octet : Bit 7 (MSB)..Bit 2 = 0 (NA) Bit 1: Tx Signaling '1'=On ; '0'=Off Bit 0 (LSB): Rx Signaling '1'=On ; '0'=Off - For VC-2/R2(FXS) external ports - 1 Octet : Bit - 7 6 5 4 3 2 1 0 |_| |_________| Call Call State Direction Bit 7 (MSB) and Bit 6 : Call Direction 00 - Incoming 01 - Outgoing Bit 5..Bit 0: Call State 000000 - Idle 000001 - Seized 000010 - Both-Way Conflict 000011 - Seizure Ack 000100 - Answered 000101 - Clear Backward 000110 - Clear Forward 000111 - Blocked 001000 - Fault 001001 - Fault 3 001010 - Fault 4 001011 - Fault 5 001100 - Fault 6 001101 - Fault 7 - For ML-20 external port - 3 Octets : - 1 MS Octet will represent the Real Rate used: Bit - 7 6 5 4 3 2 1 0 |___| |_______| spare Rate Valid values: 0..31, meaning 0..31x64Kbps Invalid values: 32..255. - 2 LS Octets will represent the Status of 7 Control Signals: Signal - --- CTS DSR DCD RJ TM DTR RTS Bit - 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Octet - 2 3 (LS) '---' will always have the value 00 Rest of the Signals (2 bits each) can have the following values: 00=NA ; 01=unused ; 10=Off ; 11=On - For ML-H/E1, ML-H/1/E1, ML-H/S/E1 internal port - 1 Octet Bit - 7 6 5 4 3 2 1 0 |___________| spare Mode of Operation Mode of Operation: '1'=Central ; '0'=Remote - For ACM external port - 1 Octet Bit - 7 6 5 4 3 2 1 0 |_________| spare Alarm State Alarm State: according to bits 1,0: 00=NA ; 01=unused ; 10=Off ; 11=On - For HS-U/1 external port - 1 Octet Bit 7 6 5 4 3 2 1 0 LSB |________| |__| |__| spare modem sync modem: 00 = other sync: 00 = not sync 01 = unknown 01 = sync 10 = ASMi-31/2 10 = reserved 11 = reserved 11 = reserved - For MTML-2/4 external ports, ML-8 externalports, ML-IP (MTML-IP) internal ports and MTML-E2 internal ports - 1 Octet : Bit 7 6 5 4 3 2 1 0 LSB | BERT State BERT State (Bit 0): 0 = OFF (BERT is not running on this port or any of its TSs/Bits) 1 = ON (BERT is running on this port OR on one of its TSs/Bits) - For ML-20N external ports - 4 Octets - 1 MS Octet will represent the Actual Link Rate: Bit - 7 6 5 4 3 2 1 0 |_| |_________| spare Rate Valid values: 0..34, meaning: 0..32 = (0..32)x64Kbps 33 = Invalid Rate 34 = not applicable (when Rate is not Auto) 35 = 0 Kbps Invalid values: 36..255. - 2 middle Octets will represent the Status of 4 Control Signals: - LS Octet - Bits 3-0: RTS/C (Command, for X.21 interface) Bits 7-4: DCD/I (Indication for X.21 interface) - MS Octet - Bits 3-0: DTR Bits 7-4: DSR Each 4 Bits are divided as follows: - 2 MS bits: DCE - 2 LS bits: DTE For each 2 bits (DCE/DTE): 00=NA ; 01=unused ; 10=Off ; 11=On. - LS Octet: (as for MTML-2): Bit 7 6 5 4 3 2 1 0 LSB | BERT State BERT State (Bit 0): 0 = OFF (BERT is not running on this port or any of its TSs/Bits) 1 = ON (BERT is running on this port OR on one of its TSs/Bits) - For MP-2100/2200 MSL-4/E1, MSL-8/E1 External ports - 3 Octets - MS octet: far-end modem channel interface - Middle octet: Material (plastic/metal), far-end modem type, synchronization with far-end modem - LS octet: BERT state (at port/TS/Bit level) - MS octet: 0000 0000 = no interface 0000 0001 = db15 (X21) 0000 0010 = IR-IP 0000 0011 = IR-ETH-Q 0000 0100 = V35 0000 0101 = ETH-RJ45 0000 0110 = G703 0000 0111 = db25 (RS530) 0000 1000 = ETH-BNC 0000 1001 = E1(Balanced) 0000 1010 = E1(Unbalanced) 0000 1011 = IR-ETH-QN Rest of the combinations: reserved - Middle octet: Bit 7 6 5 4 3 2 1 0 LSB | |___________| |__| Box material modem sync Box material modem: 00000 = other sync: 00 = not sync (for ASMi-52 SA) 00001 = unknown 01 = sync 0=metal 00010 = reserved 10 = reserved 1=plastic 00011 = reserved 11 = reserved 00100 = reserved 00101 = reserved 00110 = ASMi-52 SA/2W/Slave 00111 = ASMi-52 SA/2W/Master 01000 = ASMi-52/CQ card of LRS-24 01001 = ASMi-52/CD card of LRS-24 01010 = D16GSDSL card of DXC-3000 01011 = LRS-52 01100 = FCD-IP 01101 = FCD-IPM 01110 = D8SL card of DXC-30 01111 = ASMi-52A 10000 = MP card (SHDSL) 10001 = ASMi-52L Rest = reserved - LS Octet: (as for MTML-2): Bit 7 6 5 4 3 2 1 0 LSB | BERT State BERT State (Bit 0): 0 = OFF (BERT is not running on this port or any of its TSs) 1 = ON (BERT is running on this port OR on one of its TSs) - For MP-4100 MSL card Links - 4 Octets - MS octet: far-end modem DTE2 interface (same as for MP-2100 MSL cards) - after MS octet: far-end modem DTE1 interface (same as for MP-2100 MSL cards) - before LS octet: Material (plastic/metal), far-end modem type, synchronization with far-end modem (same as for MP-2100 MSL cards) - LS octet: BERT state (at port/TS/Bit level)- same as for MP-2100 MSL cards - For MP-4100, LRS-102 OP-108/106 Links - 3 Octets - MS octet: far-end PS type and state - Middle octet: synchronization with far-end device - LS octet: BERT state (at port/TS level) - same as for MP-2100 MSL cards - MS octet: Bit 7 6 5 4 3 2 1 0 LSB |__| |__| |__| |__| PS-A PS-A PS-B PS-B PS Type PS State PS Type PS State 00=None 00=None 01=AC-DC 01=OK 10=DC 10=Fail - Middle octet: Bit 7 6 5 4 3 2 1 0 LSB |__| sync: 00 = not sync 01 = sync 10 = reserved 11 = reserved Rest = reserved
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

prtSTestMaskXp 1.3.6.1.4.1.164.3.1.4.1.1.1.16
This is an Expanded test mask of the prtSTestMask object. The prtSTestMask object reached its maximum, being an Integer with 32 bits. This object indicates which tests from the 'prtSTstCmdXP' list are allowed for the selected port. If a specific test is allowed, its respective bit will be SET in the mask : TEST BIT ----------- --- local-loop 1 remote-loop 2 loc-and-rem-main-loops 3 remote-analog-loop 4 remote-digital-loop 5 rem-loop-on-ext-unit 6 bert 7 tone-injection 8 dlci local-loop 9 all dlci local-loop 10 dlci remote-loop 11 all dlci remote-loop 12 bert-and-rem-loop-on-rem-unit 13 rem-loop-on-rem-unit 14 block 15 backward-tone-inject 16 llb 17 rlb 18 ft1Enable 21 lbbd 22 --for 2B+D lb1 23 --for B1 lb2 24 --for B2 llb-on-rem-unit 25 bert-on-rem-unit 26 bert-on-rem-and-llb-on-rem-unit 27 local-and-bert-on-rem-unit 28 local-loop-on-rem-unit 29 localBert 30 --towards IO ports test-per-TS 31 csuLoopAndBert 32 dsuLoopAndBert 33 remoteOcuLoopAndBert 34 remoteCsuLoopAndBert 35 remoteDsuLoopAndBert 36 e.g : If the return value is 00000003 hex -> Bits 1 & 2 are set -> the allowed tests are : local-loop remote-loop
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

prtSRdnStatus 1.3.6.1.4.1.164.3.1.4.1.1.1.17
Redundancy Status of this port. noRdn - this port is not part of a Redundancy pair/group. offline - this port is offline from Redundancy point of view. online - this port is online from Redundancy point of view.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER noRdn(1), offline(2), online(3)  

prtSAlrTable 1.3.6.1.4.1.164.3.1.4.1.2
The list of port agent alarms.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtSAlrEntry

prtSAlrEntry 1.3.6.1.4.1.164.3.1.4.1.2.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtSAlrEntry  

prtSAlrIdx 1.3.6.1.4.1.164.3.1.4.1.2.1.1
A unique number to identify an entry in the alarm status table. Users should use the get next function to read this table because the indexes are not consecutive
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtSAlrSltIdx 1.3.6.1.4.1.164.3.1.4.1.2.1.2
This attribute indicates a unique identifier of the slot where the card is inserted. In the ?004 Unit the entries PsB(2),ClB(4),io6(10)..io12(16) are not valid. For the Vmux2100 Main Board clA (3) is used.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER psA(1), psB(2), clA(3), clB(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtSAlrPrtIdx 1.3.6.1.4.1.164.3.1.4.1.2.1.3
This attribute indicates a unique identifier of the port the alarm applies to. All the values are valid. No alarms exist for a port which does not exist. Valid valuesfor MP-2100/2200: exPrt1 (1) .. exPrt16 (16) , inPrt1 (101) .. inPrt48 (148), IP Bundles. For other products, see product's spec.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtSAlrCodeDescription 1.3.6.1.4.1.164.3.1.4.1.2.1.4
This attribute is a full text description of the alarm. The alarm description includes the following information: alarm code, alarm text, alarm severity, Masked or Inverted flag and counter.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

prtSAlrCode 1.3.6.1.4.1.164.3.1.4.1.2.1.5
A code identifying the alarm of an entry in the alarm status table at port level.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtSAlrSeverity 1.3.6.1.4.1.164.3.1.4.1.2.1.6
The severity of the alarm.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER event(3), minor(4), major(5), warning(6), critical(7)  

prtSAlrState 1.3.6.1.4.1.164.3.1.4.1.2.1.7
State of the alarm.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtSAlrCounter 1.3.6.1.4.1.164.3.1.4.1.2.1.8
A counter - how many times the alarm occured since last clear operation. ON and OFF Alarm will be counted separately.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtSAlrMask 1.3.6.1.4.1.164.3.1.4.1.2.1.9
Alarm mask : on/off.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtSAlrInvert 1.3.6.1.4.1.164.3.1.4.1.2.1.10
Alarm invert : on/off.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtSAlrCardType 1.3.6.1.4.1.164.3.1.4.1.2.1.11
This attribute indicates the type of card installed in the specific slot position. The enumeration is according to mdlSInstCardType.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), empty(2), ps(17), cl1(20), cl1Clk(26), vf24T1(62), vf30E1(63), vf48T1(64), vf60E1(65), vc8EandM(74), vc8Fxo(75), vc8Fxs(76), vc16EandM(77), vc16Fxo(78), vc16Fxs(79), ml8T1(134), ml8E1(135), hsr(156), ls12(159), ls6n(180), hsEthSwitch(224), hsu12(240), hsu6(241), vc4Fxs(255), vc4EandM(256), vc4Fxo(257), msl4E1W2(261), msl8E1W2(263), msl4E1W2Eth(264), msl8E1W2Eth(265), asmi54cE1AndEth(266), asmi54cT1AndEth(267), hs6N(271), hs12N(272), clx1(301), clx1GbE(302), clx1S155(303), clx1S155GbE(304), ml8T1Eth(305), ml8E1Eth(306), op106cEth(307), op108cEth(308), op106cEthT1(309), op108cEthE1(310), op108cEthE1Unbal(311), mpw1(312), vfs24T1(321), vfs30E1(322), vfs48T1(323), vfs60E1(324)  

prtFrStatisTable 1.3.6.1.4.1.164.3.1.4.1.3.1.1
This table is applicable only for an active port running an FR protocol .
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtFrStatisEntry

prtFrStatisEntry 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtFrStatisEntry  

prtFrStatisSltIdx 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.1
This attribute indicates a unique slot position where the module is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid. For stand-alone units this index will be notApplicable (255).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtFrStatisPrtIdx 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.2
This attribute indicates a unique port number.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6)  

prtFrStatisInvIdx 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.3
The Interval of 15 min. for which the following statistics counters are applicable.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER currentInv(1), last(2)  

prtFrTimeElapsed 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.4
The number of seconds that have elapsed since the beginning of the current error-measurement interval. This object is applicable mainly for the current interval. For other interval: - if data is available: value will be 899. - if data is not available: value will be 0.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..899  

prtFrRxTotalFrames 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.5
The total number of frames received by this port during the selected interval.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

prtFrTxTotalFrames 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.6
The total number of frames sent by this port during the selected interval.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

prtFrRxTotalBytes 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.7
The total number of bytes received by this port during the selected interval.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

prtFrTxTotalBytes 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.8
The total number of bytes sent by this port during the selected interval.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

prtFrRxMngFrames 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.9
The management number of frames received by this port during the selected interval.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

prtFrTxMngFrames 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.10
The management number of frames sent by this port during the selected interval.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

prtFrRxDeFrames 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.11
The number of De frames received by this port during the selected interval.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

prtFrTxDeFrames 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.12
The number of De frames sent by this port during the selected interval.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

prtFrRxDcrdCongDeFr 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.13
The number of De frames discarded due to congestion, received by this port during the selected interval.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

prtFrTxDcrdCongDeFr 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.14
The number of De frames discarded due to congestion, sent by this port during the selected interval.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

prtFrRxDcrdCongAllFr 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.15
All the frames discarded due to congestion, received by this port during the selected interval.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

prtFrTxDcrdCongAllFr 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.16
All the frames discarded due to congestion, sent by this port during the selected interval.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

prtFrRxFecn 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.17
Number of frames received by this port during the selected interval, indicating forward congestion.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

prtFrTxFecn 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.18
Number of frames sent by this port during the selected interval, indicating forward congestion.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

prtFrRxBecn 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.19
Number of frames received by this port during the selected interval, indicating backward congestion.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

prtFrTxBecn 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.20
Number of frames sent by this port during the selected interval, indicating backward congestion.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

prtFrRxBeViol 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.21
Number of data frames received by this port during the selected interval, exceeding the Burst Excess value.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

prtFrTxBeViol 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.22
Number of data frames sent by this port during the selected interval, exceeding the Burst Excess value.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

prtFrRxBcViol 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.23
Number of data frames received by this port during the selected interval, exceeding the Burst Committed value.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

prtFrTxBcViol 1.3.6.1.4.1.164.3.1.4.1.3.1.1.1.24
Number of data frames sent by this port during the selected interval, exceeding the Burst Committed value.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

prtCrStatisTable 1.3.6.1.4.1.164.3.1.4.1.3.2.1
This table is applicable only for an active port running a CR protocol .
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtCrStatisEntry

prtCrStatisEntry 1.3.6.1.4.1.164.3.1.4.1.3.2.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtCrStatisEntry  

prtCrStatisSltIdx 1.3.6.1.4.1.164.3.1.4.1.3.2.1.1.1
This attribute indicates a unique slot position where the module is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid. For stand-alone units this index will be notApplicable (255).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtCrStatisPrtIdx 1.3.6.1.4.1.164.3.1.4.1.3.2.1.1.2
This attribute indicates a unique port number.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6)  

prtCrStatisInvIdx 1.3.6.1.4.1.164.3.1.4.1.3.2.1.1.3
The Interval of 15 min. for which the following statistics counters are applicable.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER currentInv(1), last(2)  

prtCrTimeElapsed 1.3.6.1.4.1.164.3.1.4.1.3.2.1.1.4
The number of seconds that have elapsed since the beginning of the current error-measurement interval. This object is applicable mainly for the current interval. For other interval: - if data is available: value will be 899. - if data is not available: value will be 0.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..899  

prtCrRxTotalCells 1.3.6.1.4.1.164.3.1.4.1.3.2.1.1.5
The total number of cells received by this port during the selected interval.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

prtCrTxTotalCells 1.3.6.1.4.1.164.3.1.4.1.3.2.1.1.6
The total number of cells sent by this port during the selected interval.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

prtCrRxDataCells 1.3.6.1.4.1.164.3.1.4.1.3.2.1.1.7
The number of Data Cells received by this port during the selected interval.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

prtCrTxDataCells 1.3.6.1.4.1.164.3.1.4.1.3.2.1.1.8
The number of Data Cells sent by this port during the selected interval.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

prtDlciStatisTable 1.3.6.1.4.1.164.3.1.4.1.3.3.1
This table is applicable only for an active port running an FR, FR+ or CR protocol, with valid DLCIs .
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtDlciStatisEntry

prtDlciStatisEntry 1.3.6.1.4.1.164.3.1.4.1.3.3.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtDlciStatisEntry  

prtDlciSltIdx 1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.1
This attribute indicates a unique slot position where the module is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid. For stand-alone units this index will be notApplicable (255).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtDlciPrtIdx 1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.2
This attribute indicates a unique port number.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6)  

prtDlciIdx 1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.3
This attribute indicates a unique DLCI index for each valid DLCI (16..991).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..991  

prtDlciRxDeFrames 1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.4
The number of De frames received by this DLCI.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

prtDlciTxDeFrames 1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.5
The number of De frames sent by this DLCI.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

prtDlciRxDcrdCongDeFr 1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.6
The number of De frames discarded due to congestion, received by this DLCI.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

prtDlciTxDcrdCongDeFr 1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.7
The number of De frames discarded due to congestion, sent by this DLCI.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

prtDlciRxDcrdCongAllFr 1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.8
All the frames discarded due to congestion, received by this DLCI.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

prtDlciTxDcrdCongAllFr 1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.9
All the frames discarded due to congestion, sent by this DLCI.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

prtDlciTxFecn 1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.10
Number of frames sent by this DLCI, indicating forward congestion.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

prtDlciTxBecn 1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.11
Number of frames sent by this DLCI, indicating backward congestion.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

prtDlciRxBeViol 1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.12
Number of data frames received by this DLCI, exceeding the Burst Excess value.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

prtDlciTxBeViol 1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.13
Number of data frames sent by this DLCI, exceeding the Burst Excess value.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

prtDlciRxBcViol 1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.14
Number of data frames received by this DLCI, exceeding the Burst Committed value.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

prtDlciTxBcViol 1.3.6.1.4.1.164.3.1.4.1.3.3.1.1.15
Number of data frames sent by this DLCI, exceeding the Burst Committed value.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

prtT1FdlMsgTable 1.3.6.1.4.1.164.3.1.4.1.3.4.1
This table is applicable for a T1 interface with 'esf' LineType .
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtT1FdlMsgEntry

prtT1FdlMsgEntry 1.3.6.1.4.1.164.3.1.4.1.3.4.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtT1FdlMsgEntry  

prtT1FdlMsgSltIdx 1.3.6.1.4.1.164.3.1.4.1.3.4.1.1.1
This attribute indicates a unique slot position where the module is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtT1FdlMsgPrtIdx 1.3.6.1.4.1.164.3.1.4.1.3.4.1.1.2
This attribute indicates a unique port number. MTML-1/T1 modules have just one external interface.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER exPrt1(1)  

prtT1FdlMsgFdlTxRx 1.3.6.1.4.1.164.3.1.4.1.3.4.1.1.3
The Fdl tx/rx reference of the Fdl message.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER tx(1), rx(2)  

prtT1FdlMsg 1.3.6.1.4.1.164.3.1.4.1.3.4.1.1.4
FDL message.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

prtExTsSplitTable 1.3.6.1.4.1.164.3.1.4.2.1
The write operation into the Table Objects is valid only to the TmpCnfg entry, except prtExTsBitTest that will be written directly to the Active Configuration.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExTsSplitEntry

prtExTsSplitEntry 1.3.6.1.4.1.164.3.1.4.2.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtExTsSplitEntry  

prtExTsCnfgIdx 1.3.6.1.4.1.164.3.1.4.2.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

prtExTsSltIdx 1.3.6.1.4.1.164.3.1.4.2.1.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid. notApplicable - for stand-alone units.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtExTsPrtIdx 1.3.6.1.4.1.164.3.1.4.2.1.1.3
This attribute indicates a unique port number. Most ML cards have only one external interface. inPrt1 - for MTML-H/E1 cards. For other products' index see their specification.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtExTsIdx 1.3.6.1.4.1.164.3.1.4.2.1.1.4
This attribute indicates a unique time slot position. The valid time slots are: 1..24 for T1 Card and 1..31 for E1 interface. In G732S-E1 lines, time slot 16 is not valid for data, it is dedicated to multiframe synchronization bits and voice signaling.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtExTsBit 1.3.6.1.4.1.164.3.1.4.2.1.1.5
This attribute indicates a unique Bit within the time slot. The valid Bits are: 1..8. 255=NA.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtExTsIConSlot 1.3.6.1.4.1.164.3.1.4.2.1.1.6
This attribute indicates whether the specified time slot is connected/routed internally in the Agent and to which card it is connected. In the ?004 Unit the entries io6(10)..io12(16) are not valid. notApplicable - for stand-alone units.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noConnect(2), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtExTsIConPrt 1.3.6.1.4.1.164.3.1.4.2.1.1.7
This attribute indicates the internally (In Mux) connected/routed port. For other products' index see their specification.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtExTsBitTest 1.3.6.1.4.1.164.3.1.4.2.1.1.8
This attribute indicates a test to be activated on the selected Bit. It is applicable only when prtExPh1MlTsTest=split(254). none - no test is applied for the selected Bit. notApplicable - when prtExPh1MlTsTest is NOT split(254).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), remoteBert(8), localBert(30), notApplicable(255)  

prtExTsTxSignaling 1.3.6.1.4.1.164.3.1.4.2.1.1.9
Link - Tx Signaling per TS, for TSs having TS Type=Voice (agnTsType=voice(2)). It monitors what is sent to Link for the selected TS, for A,B,C,D Signaling Bits. Bit 1= LSB Bit 8= MSB Bit 1-2 = A Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA Bit 3-4 = B Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA Bit 5-6 = C Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA Bit 7-8 = D Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

prtExTsRxSignaling 1.3.6.1.4.1.164.3.1.4.2.1.1.10
Link - Rx Signaling per TS, for TSs having TS Type=Voice (agnTsType=voice(2)). It monitors what is received from Link for the selected TS, for A,B,C,D Signaling Bits. Bit 1= LSB Bit 8= MSB Bit 1-2 = A Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA Bit 3-4 = B Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA Bit 5-6 = C Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA Bit 7-8 = D Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

prtExTsTxIoSignaling 1.3.6.1.4.1.164.3.1.4.2.1.1.11
IO - Tx Signaling per TS, for TSs having TS Type=Voice (agnTsType=voice(2)). It monitors what is sent to IO port for the selected TS, for A,B,C,D Signaling Bits. Bit 1= LSB Bit 8= MSB Bit 1-2 = A Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA Bit 3-4 = B Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA Bit 5-6 = C Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA Bit 7-8 = D Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

prtExTsRxIoSignaling 1.3.6.1.4.1.164.3.1.4.2.1.1.12
IO - Rx Signaling per TS, for TSs having TS Type=Voice (agnTsType=voice(2)). It monitors what is received from IO port for the selected TS, for A,B,C,D Signaling Bits. Bit 1= LSB Bit 8= MSB Bit 1-2 = A Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA Bit 3-4 = B Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA Bit 5-6 = C Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA Bit 7-8 = D Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

prtCnfgAgenda 1.3.6.1.4.1.164.3.1.4.2.2
OBJECT IDENTIFIER    

prtAgendaBehaviourTable 1.3.6.1.4.1.164.3.1.4.2.2.1
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtAgendaBehaviourEntry

prtAgendaBehaviourEntry 1.3.6.1.4.1.164.3.1.4.2.2.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtAgendaBehaviourEntry  

prtAgendaBehaviourCnfgIdx 1.3.6.1.4.1.164.3.1.4.2.2.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

prtAgendaBehaviourSltIdx 1.3.6.1.4.1.164.3.1.4.2.2.1.1.2
This parameter should be: - slot number for MX3000 - 255 = N/A for MX300/30.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtAgendaBehaviourPrtIdx 1.3.6.1.4.1.164.3.1.4.2.2.1.1.3
This parameter should be: - port number for MX300/30 - 100 = N/A for MX3000.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtAgendaBehaviourOnOff 1.3.6.1.4.1.164.3.1.4.2.2.1.1.4
Setting this command to on(3) enables the agenda function at module (3000) or port (300/30) level.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), off(2), on(3)  

prtCnfgAgendaTable 1.3.6.1.4.1.164.3.1.4.2.2.2
This table allows the user to schedule the time a session is active per week basis.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtCnfgAgendaEntry

prtCnfgAgendaEntry 1.3.6.1.4.1.164.3.1.4.2.2.2.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtCnfgAgendaEntry  

prtCnfgAgendaCnfgIdx 1.3.6.1.4.1.164.3.1.4.2.2.2.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

prtCnfgAgendaSltIdx 1.3.6.1.4.1.164.3.1.4.2.2.2.1.2
This attribute is equal to: -slot number for MX3000 -255 = N/A for MX300/30
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtCnfgAgendaPrtIdx 1.3.6.1.4.1.164.3.1.4.2.2.2.1.3
This attribute is equal to: - port number for MX300/30 - port number for MX3000. For example 1-4 in MHS-4 cards. - 100 = N/A for MX3000 when not used.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtCnfgAgendaDayIdx 1.3.6.1.4.1.164.3.1.4.2.2.2.1.4
This attribute for which day of the week this row applies.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER monday(1), tuesday(2), wednesday(3), thursday(4), friday(5), saturday(6), sunday(7)  

prtCnfgAgendaSesId 1.3.6.1.4.1.164.3.1.4.2.2.2.1.5
The user may define 4 different active intervals per day.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..4  

prtCnfgAgendaFrom 1.3.6.1.4.1.164.3.1.4.2.2.2.1.6
Start from time interval in seconds.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..86400  

prtCnfgAgendaTo 1.3.6.1.4.1.164.3.1.4.2.2.2.1.7
To time interval in seconds.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..86400  

prtGenCnfgTable 1.3.6.1.4.1.164.3.1.4.2.3
This table allows the user to configure general port parameters.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtGenCnfgEntry

prtGenCnfgEntry 1.3.6.1.4.1.164.3.1.4.2.3.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtGenCnfgEntry  

prtGenCnfgIdx 1.3.6.1.4.1.164.3.1.4.2.3.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. The write operation is valid only to the TmpCnfg.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

prtGenCnfgSltIdx 1.3.6.1.4.1.164.3.1.4.2.3.1.2
This attribute indicates a unique slot position where the card is inserted.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER clA(3), clB(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtGenCnfgPrtIdx 1.3.6.1.4.1.164.3.1.4.2.3.1.3
This attribute indicates a unique external or internal port number. For MP: exPrt1 (1) .. exPrt16 (16) , notApplicable(100), inPrt1 (101) .. inPrt84 (184)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtGenCnfgLinkToSlot 1.3.6.1.4.1.164.3.1.4.2.3.1.4
This attribute indicates the slot of the ML card to which the IO port is mapped.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER clA(3), clB(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtGenCnfgLinkToPort 1.3.6.1.4.1.164.3.1.4.2.3.1.5
This attribute indicates the port in the prtGenCnfgLinkToSlot of the ML card to which the IO port is mapped. For MP: exPrt1 (1) , exPrt2 (2) , exPrt3 (3) , exPrt4 (4) , exPrt5 (5) , exPrt6 (6) , exPrt7 (7) , exPrt8 (8) , inPrt1 (101) , inPrt2 (102) , inPrt3 (103) , inPrt4 (104) , inPrt5 (105) , inPrt6 (106) , inPrt7 (107) , inPrt8 (108) , inPrt9 (109), inPrt10 (110), inPrt11 (111), inPrt12 (112), inPrt13 (113), inPrt14 (114), inPrt15 (115), inPrt16 (116), inPrt17 (117), inPrt18 (118), inPrt19 (119), inPrt20 (120), inPrt21 (121), inPrt22 (122), inPrt23 (123), inPrt24 (124), inPrt25 (125), inPrt26 (126), inPrt27 (127), inPrt28 (128), inPrt29 (129), inPrt30 (130), inPrt31 (131), inPrt32 (132), inPrt33 (133), inPrt34 (134), inPrt35 (135), inPrt36 (136), inPrt37 (137), inPrt38 (138), inPrt39 (139), inPrt40 (140), inPrt41 (141), inPrt42 (142), inPrt43 (143), inPrt44 (144), inPrt45 (145), inPrt46 (146), inPrt47 (147), inPrt48 (148), inPrt49 (149), inPrt50 (150), inPrt51 (151), inPrt52 (152), inPrt53 (153), inPrt54 (154), inPrt55 (155), inPrt56 (156), inPrt57 (157), inPrt58 (158), inPrt59 (159), inPrt60 (160), inPrt61 (161), inPrt62 (162), inPrt63 (163), inPrt64 (164), inPrt65 (165), inPrt66 (166), inPrt67 (167), inPrt68 (168), inPrt69 (169), inPrt70 (170), inPrt71 (171), inPrt72 (172), inPrt73 (173), inPrt74 (174), inPrt75 (175), inPrt76 (176), inPrt77 (177), inPrt78 (178), inPrt79 (179), inPrt80 (180), inPrt81 (181), inPrt82 (182), inPrt83 (183), inPrt84 (184), notApplicable (255)
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtGenCnfgPortId 1.3.6.1.4.1.164.3.1.4.2.3.1.6
IO Port Id for V5.1 use. This object is applicable only for part of the PSTN and ISDN IO ports. Generally, 0 is a valid value. Nevertheless, for ports that do not support this object, the value will be: notApplicable= 0
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..16777215  

prtGenCnfgBusConnection 1.3.6.1.4.1.164.3.1.4.2.3.1.7
This object indicates the support of the card regarding Bus Connection. Same value for all ports of the card. partial = 2 Buses (AB) full = 4 Buses (ABCD) partial CD = 2 Buses CD Actually the support depends on the card's HW. But, since CL has to assign data on Buses even when the card is not installed, this object has to be configured. If the actual card installed will not match the value configured, an Alarm will be issued.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), partial(2), full(3), partialCD(4)  

prtGenCnfgInbandMng 1.3.6.1.4.1.164.3.1.4.2.3.1.8
This object indicates whether Inband Management is used over the link.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), off(2), on(3)  

prtGenCnfgInbandMngRoutProt 1.3.6.1.4.1.164.3.1.4.2.3.1.9
This object indicates the Inband Mng Routing Protocol of the port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), rip2(2), proprietaryRip(3), notApplicable(255)  

prtGenCnfgProtectionMode 1.3.6.1.4.1.164.3.1.4.2.3.1.10
This object indicates the Protection Mode of the port. notApplicable- when Bus Protection Point=No. For VC-4/Omni card this object is supported RO.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), secondary(2), primary(3)  

prtGenCnfgConnect 1.3.6.1.4.1.164.3.1.4.2.3.1.11
This object indicates whether the port should be considered in any of the mux algorithms.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtGenCnfgSignalingType 1.3.6.1.4.1.164.3.1.4.2.3.1.12
This object selects the Type of Signaling used by the port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER legacy(3), abcd(4), none(5)  

prtCmprTable 1.3.6.1.4.1.164.3.1.4.3.1
A table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtCmprEntry

prtCmprEntry 1.3.6.1.4.1.164.3.1.4.3.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtCmprEntry  

prtCmprTypIdx 1.3.6.1.4.1.164.3.1.4.3.1.1.1
This attribute indicates the Type of the Compressed being referred.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtCmprCnfgIdx 1.3.6.1.4.1.164.3.1.4.3.1.1.2
This attribute indicates the configuration to which the Compressed information is related.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtCmprVersion 1.3.6.1.4.1.164.3.1.4.3.1.1.3
This attribute indicates the version of the internal format of the Compressed data
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtCmprSltIdx 1.3.6.1.4.1.164.3.1.4.3.1.1.4
This attribute indicates a unique number of the slot position where the card is inserted. In the ?004 Unit the entries psB(2),clB(4),io6(10)..io(16) are not valid.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER psA(1), psB(2), clA(3), clB(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtCmprPrtIdx 1.3.6.1.4.1.164.3.1.4.3.1.1.5
This attribute indicates a unique identifier of the port the compressed information relates to. Valid values: exPrt1 (1) .. exPrt16 (16) , inPrt1 (101) .. inPrt48 (148).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtCmprObj 1.3.6.1.4.1.164.3.1.4.3.1.1.6
This attribute is the compressed information itself.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

prtCmprStatisticObj 1.3.6.1.4.1.164.3.1.4.3.1.1.7
This attribute is the compressed statistics information itself.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

prtDlciCmprTable 1.3.6.1.4.1.164.3.1.4.3.2
A table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtDlciCmprEntry

prtDlciCmprEntry 1.3.6.1.4.1.164.3.1.4.3.2.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtDlciCmprEntry  

prtDlciCmprCnfgIdx 1.3.6.1.4.1.164.3.1.4.3.2.1.1
This attribute indicates the configuration to which the Compressed information is related.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtDlciCmprVersion 1.3.6.1.4.1.164.3.1.4.3.2.1.2
This attribute indicates the version of the internal format of the Compressed data
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtDlciCmprSltIdx 1.3.6.1.4.1.164.3.1.4.3.2.1.3
This attribute indicates a unique number of the slot position where the module is inserted. In the ?004 Unit the entries psB(2),clB(4),io6(10)..io(16) are not valid.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtDlciCmprPrtIdx 1.3.6.1.4.1.164.3.1.4.3.2.1.4
This attribute indicates a unique identifier of the port the compressed information relates to. All the values are valid.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6), exPrt7(7), exPrt8(8), exPrt9(9), exPrt10(10), inPrt1(101), inPrt2(102), inPrt3(103), inPrt4(104), inPrt5(105), inPrt6(106), inPrt7(107), inPrt8(108), inPrt9(109), inPrt10(110), inPrt11(111), inPrt12(112)  

prtDlciCmprDlciIdx 1.3.6.1.4.1.164.3.1.4.3.2.1.5
This attribute indicates a unique identifier of the Dlci the compressed information relates to. The values are between 16 - 991.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtDlciCmprObj 1.3.6.1.4.1.164.3.1.4.3.2.1.6
This attribute is the compressed information itself.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

prtAlarmsCmprTable 1.3.6.1.4.1.164.3.1.4.3.3
A table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtAlarmsCmprEntry

prtAlarmsCmprEntry 1.3.6.1.4.1.164.3.1.4.3.3.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtAlarmsCmprEntry  

prtAlarmsCmprVersion 1.3.6.1.4.1.164.3.1.4.3.3.1.1
This attribute indicates the version of the internal format of the Compressed data
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtAlarmsCmprAlarmSlot 1.3.6.1.4.1.164.3.1.4.3.3.1.2
This attribute indicates the desired slot position. In the ?004 Unit the entries PsB(2),ClB(4),io6(10)..io(16) are not valid. For Stand-alone units, notApplicable(255) will appear.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtAlarmsCmprAlarmPort 1.3.6.1.4.1.164.3.1.4.3.3.1.3
This attribute indicates a unique identifier of the port the alarm applies to. All the values are valid. No alarms exist for a non-existing port. IP Bundles are considered a port too, for this matter.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtAlarmsCmprAlarmIdx 1.3.6.1.4.1.164.3.1.4.3.3.1.4
A unique number to identify an entry in the alarm status table of the agent.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtAlarmsCmprObj 1.3.6.1.4.1.164.3.1.4.3.3.1.5
This attribute is the compressed information itself.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

prtSExHsfStatTable 1.3.6.1.4.1.164.3.2.3.1.6
A table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtSExHsfStatEntry

prtSExHsfStatEntry 1.3.6.1.4.1.164.3.2.3.1.6.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtSExHsfStatEntry  

prtSExHsfSltIdx 1.3.6.1.4.1.164.3.2.3.1.6.1.1
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtSExHsfPrtIdx 1.3.6.1.4.1.164.3.2.3.1.6.1.2
This attribute indicates a unique port number.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6), exPrt7(7), exPrt8(8), exPrt9(9), exPrt10(10), exPrt11(11), exPrt12(12)  

prtSExHsfInterfaceTyp 1.3.6.1.4.1.164.3.2.3.1.6.1.3
This attribute indicates a unique interface type of a selected port.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), v35(2), rs422(3)  

prtSExHsfRts 1.3.6.1.4.1.164.3.2.3.1.6.1.4
This attribute indicates a unique RTS control signal state.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), notActive(2), active(3)  

prtIsdnStatusTable 1.3.6.1.4.1.164.3.2.3.1.16
This table contains ISDN Statistics parameters that do not appear in the standard MIBs or for agents that don't support the standard Index of Call Set Up Time.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtIsdnStatusEntry

prtIsdnStatusEntry 1.3.6.1.4.1.164.3.2.3.1.16.1
Entries for ISDN Statistics parameters that do not appear in the standard MIBs or for agents that don't support the standard Index of Call Set Up Time.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtIsdnStatusEntry  

prtIsdnStatusDspMode 1.3.6.1.4.1.164.3.2.3.1.16.1.1
The DSP can be in one of the following Modes: Voice, Idle, Fax, Voice Band Data (VBD)- Modem.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER voice(2), idle(3), fax(4), vbd(5)  

prtIsdnStatusCallState 1.3.6.1.4.1.164.3.2.3.1.16.1.2
The state that the current call is in.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER present(2), overlapReceive(3), incoming(4), receive(5), initiated(6), overlapSend(7), outGoingProceed(8), callDeliver(9), active(10), disconnectIndicate(11), releaseRequest(12), disconnectReq(13), notActive(14)  

prtIsdnStatusCallingNumber 1.3.6.1.4.1.164.3.2.3.1.16.1.3
This is the local Number (ISDN Address) associated with this entry.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

prtIsdnStatusCalledNumber 1.3.6.1.4.1.164.3.2.3.1.16.1.4
This is the remote Number (ISDN Address) associated with this entry.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

prtIsdnStatusCalledIP 1.3.6.1.4.1.164.3.2.3.1.16.1.5
This is the remote IP Address associated with this entry.
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

prtIsdnStatusCallDirection 1.3.6.1.4.1.164.3.2.3.1.16.1.6
Attribute indicating the Direction of the Call. The value of notApplicable will be used for example when prtIsdnStatusCallState = notActive(14).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), incoming(2), outgoing(3)  

cnfgMdlMux 1.3.6.1.4.1.164.3.2.2.1
OBJECT IDENTIFIER    

mdlPbxFramerCnfg 1.3.6.1.4.1.164.3.2.2.1.1
OBJECT IDENTIFIER    

mdlPbxFramerCnfgTable 1.3.6.1.4.1.164.3.2.2.1.1.1
This table contains parameters relevant to a module belonging to a digital voice system, except mdlPbxFraEnhEcho which is relevant also for analog cards.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MdlPbxFramerCnfgEntry

mdlPbxFramerCnfgEntry 1.3.6.1.4.1.164.3.2.2.1.1.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  MdlPbxFramerCnfgEntry  

mdlPbxFraCnfgIdx 1.3.6.1.4.1.164.3.2.2.1.1.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

mdlPbxFraSltIdx 1.3.6.1.4.1.164.3.2.2.1.1.1.1.2
The slot relevant to this module.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

mdlPbxFraEnhEcho 1.3.6.1.4.1.164.3.2.2.1.1.1.1.3
Refers to external ports of an analogue module and to the internal ports of the other mvc4 types of modules. ms16(3) means that the four voice ports have enhanced echo of 16ms. ms32(4) means that the two first ports have enhanced echo of 32 ms while the last two ports have no enhanced echo.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), ms16(3), ms32(4)  

mdlPbxFraTSGroupAss 1.3.6.1.4.1.164.3.2.2.1.1.1.1.4
In case of T1 modules: group1=(1,2,3,4), ...., group6=(21,22,23,24) while in case of E1 modules: - If prtExPh1MlLineType=g732sE1 or g732sE1CRC: group1=(1,2,3,4),..,group4=(13,14,15,17), group5=(18,19,20,21),...,group7=(26,27,28,29) group8=(30,31). - If prtExPh1MlLineType=g732nE1 or g732nE1CRC: group1=(1,2,3,4),..,group4=(13,14,15,16), group5=(17,18,19,20),...,group7=(25,26,27,28) group8=(29,30,31).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER group1(1), group2(2), group3(3), group4(4), group5(5), group6(6), group7(7), group8(8), notApplicable(255)  

mdlPbxFraSignalMode 1.3.6.1.4.1.164.3.2.2.1.1.1.1.5
Refers to the signaling mode of the Framer module. tieTrunk(2), tieInvert(3), casTrans(4) are standard coding of the signaling protocol. casTrans(4) is Channel Associated Signaling (the signaling is within the channels time slot). ccsTrans(6) is Transparent Common Channel Signaling (the signaling is not within the channels time slot - a TS for signaling is used). userDefined(5) allows the user to define the signaling protocol he wants. In this case, the next two MIB fields are relevant.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), tieTrunk(2), tieInvert(3), casTrans(4), userDefined(5), ccsTrans(6), noSignaling(7)  

mdlPbxFraSignalVector 1.3.6.1.4.1.164.3.2.2.1.1.1.1.6
In the case of mdlPbxFraSignalMode = userDefined(5), this field defines the A,B,C Bits. D bit is supplied for future versions. Bit 1 = Bit A ON Hook - Local Bit 2 = Bit B ON Hook - Local Bit 3 = Bit C ON Hook - Local Bit 4 = Bit D ON Hook - Local Bit 5 = Bit A OFF Hook - Local Bit 6 = Bit B OFF Hook - Local Bit 7 = Bit C OFF Hook - Local Bit 8 = Bit D OFF Hook - Local Bit 9 = Bit A ON Hook - Remote Bit 10 = Bit B ON Hook - Remote Bit 11 = Bit C ON Hook - Remote Bit 12 = Bit D ON Hook - Remote Bit 13 = Bit A OFF Hook - Remote Bit 14 = Bit B OFF Hook - Remote Bit 15 = Bit C OFF Hook - Remote Bit 16 = Bit D OFF Hook - Remote In conjunction with the Mask, mdlPbxFraSignalMask, it is possible to compute the signal mode.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

mdlPbxFraSignalMask 1.3.6.1.4.1.164.3.2.2.1.1.1.1.7
In the case of mdlPbxFraSignalMode = userDefined(5), this field defines the 'don't care' A,B,C Bits. D bit is supplied for future versions. Bit 1 = Bit A ON Hook - Local Bit 2 = Bit B ON Hook - Local Bit 3 = Bit C ON Hook - Local Bit 4 = Bit D ON Hook - Local Bit 5 = Bit A OFF Hook - Local Bit 6 = Bit B OFF Hook - Local Bit 7 = Bit C OFF Hook - Local Bit 8 = Bit D OFF Hook - Local Bit 9 = Bit A ON Hook - Remote Bit 10 = Bit B ON Hook - Remote Bit 11 = Bit C ON Hook - Remote Bit 12 = Bit D ON Hook - Remote Bit 13 = Bit A OFF Hook - Remote Bit 14 = Bit B OFF Hook - Remote Bit 15 = Bit C OFF Hook - Remote Bit 16 = Bit D OFF Hook - Remote.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

mdlPbxFraFramerSlot 1.3.6.1.4.1.164.3.2.2.1.1.1.1.8
Slot where is sitting the Framer.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

mdlPbxFraSignaling 1.3.6.1.4.1.164.3.2.2.1.1.1.1.9
Signaling - describes the way the signaling ABCD bits pass from the local extension to the remote extension and vice-versa. endToEnd = the signaling ABCD bits pass without change from local to remote extension. localTermination = the signaling ABCD bits received from the local extension are translated to different ON Hook/OFF Hook bit values and then passed to remote extension. This is relevant when the Local and Remote ON Hook/OFF Hook values are different.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), endToEnd(2), localTermination(3)  

mdlPbxFraTransSigTs 1.3.6.1.4.1.164.3.2.2.1.1.1.1.10
This is the Time Slot that is used for Transparent CCS signaling. The values of this TS are 1-24 for T1 & 1-31 for E1. The default for E1 is 16 & for T1 it is 24. If no signaling is used then the TS should be 255 (None).
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

mdlProtIpTable 1.3.6.1.4.1.164.3.2.2.1.2
This table contains Protected IP Addresses for ML-IP cards when working in IP Ring Mode.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MdlProtIpEntry

mdlProtIpEntry 1.3.6.1.4.1.164.3.2.2.1.2.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  MdlProtIpEntry  

mdlProtIpCnfgIdx 1.3.6.1.4.1.164.3.2.2.1.2.1.1
This attribute indicates the Idx of the Cnfg being accessed. Idx 255 relates to the TmpCnfg. For Agents having several configuration, Write operation is allowed only to the Temporary Configuration.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

mdlProtIpSlotIdx 1.3.6.1.4.1.164.3.2.2.1.2.1.2
This attribute indicates a unique slot position where the module is inserted. In the 2104 Unit the entries io6(10)..io16) are not valid.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

mdlProtIpAddress 1.3.6.1.4.1.164.3.2.2.1.2.1.3
A Protected IP address.
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

mdlProtIpRowStatus 1.3.6.1.4.1.164.3.2.2.1.2.1.4
This parameter allows creating/deleting entries of this table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

statMdlMux 1.3.6.1.4.1.164.3.2.2.2
OBJECT IDENTIFIER    

mdlStatTable 1.3.6.1.4.1.164.3.2.2.2.1
A table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MdlStatEntry

mdlStatEntry 1.3.6.1.4.1.164.3.2.2.2.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  MdlStatEntry  

mdlStatSltIdx 1.3.6.1.4.1.164.3.2.2.2.1.1.1
A unique number to identify a slot position in the mux. In the 2104 Unit the entries psB(2),clB(4),io6(10)..io12(16) are not valid.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER psA(1), psB(2), clA(3), clB(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

mdlStatHostIP 1.3.6.1.4.1.164.3.2.2.2.1.1.2
The host interface IP address when DHCP Client=Yes. This object is relevant only when DHCP Client=Yes
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

mdlStatHostMask 1.3.6.1.4.1.164.3.2.2.2.1.1.3
The host interface subnet mask when DHCP Client=Yes. This object is relevant only when DHCP Client=Yes
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

mdlStatDefaultGateway 1.3.6.1.4.1.164.3.2.2.2.1.1.4
Default Gateway's IP Address when DHCP Client=Yes. This object is relevant only when DHCP Client=Yes
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

prtExClCnfgTable 1.3.6.1.4.1.164.3.2.3.2.1.1
A table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExClCnfgEntry

prtExClCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.1.1.1
All the entries at this table are identical (have the same value) for all the configurations (1..100) except the TmpCnfg. The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtExClCnfgEntry  

prtExClCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.1.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

prtExClSltIdx 1.3.6.1.4.1.164.3.2.3.2.1.1.1.2
This attribute indicates a unique slot position where the card is inserted. Because the second Cl is only for redundancy, all the parameters are identical in the two modules, i.e. change of any parameter in one module will change automatically the value of the other module.. In the ?004 Unit the entry clB(4) is not valid.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER clA(3), clB(4), notApplicable(255)  

prtExClPrtIdx 1.3.6.1.4.1.164.3.2.3.2.1.1.1.3
This attribute indicates a unique port number.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2)  

prtExClUsage 1.3.6.1.4.1.164.3.2.3.2.1.1.1.4
This attribute indicates what is the usage of the port.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), noUse(2), nmsSlip(3), nmsPpp(4), muxSlip(5), muxPpp(6), terminal(7)  

prtExClRate 1.3.6.1.4.1.164.3.2.3.2.1.1.1.5
This attribute indicates the operation rate of the port.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER r300Bps(1), r1200Bps(2), r2400Bps(3), r4800Bps(4), r9600Bps(5), r19200Bps(6), r38400Bps(7), r57600Bps(8), r115200Bps(9)  

prtExClDataBits 1.3.6.1.4.1.164.3.2.3.2.1.1.1.6
This attribute indicates the number of data bits in async frame
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER dataBits7Bits(1), dataBits8Bits(2)  

prtExClParity 1.3.6.1.4.1.164.3.2.3.2.1.1.1.7
This attribute indicates if the parity operation mode in async frame
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER odd(1), even(2), none(3)  

prtExClStopBits 1.3.6.1.4.1.164.3.2.3.2.1.1.1.8
This attribute indicates the minimum number of stop bits in the tx async frame
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER stopBits1Bit(1), stopBits1dot5Bits(2), stopBits2Bits(3)  

prtExClRoutingProtocol 1.3.6.1.4.1.164.3.2.3.2.1.1.1.9
This attribute indicates the routing protocol of the port. When prtExClUsage is nmsSlip or nmsPpp - all values are applicable . Else - only 'none' is applicable.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(1), rip2(2)  

prtExClEnabled 1.3.6.1.4.1.164.3.2.3.2.1.1.1.10
This attribute indicates if Ethernet port of CL is enabled or not for management. It is applicable only on the ETH port of the CL, when the MP includes an ML-IP card. disabled - will happen when there is Inband Management via the ML-IP link/s enabled - will happen when ML-IP link/s is not used for Inband Management, but CL's ETH port .
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

prtExPh1MlCnfgTable 1.3.6.1.4.1.164.3.2.3.2.2.1
- For products supporting more than one configuration, the write operation into the Table is valid only to the TmpCnfg entry. - For products that do not support configurations, the write operation into the Table will be to prtExPh1MlCnfgIdx=1.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExPh1MlCnfgEntry

prtExPh1MlCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.2.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtExPh1MlCnfgEntry  

prtExPh1MlCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.2.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

prtExPh1MlSltIdx 1.3.6.1.4.1.164.3.2.3.2.2.1.1.2
This attribute indicates a unique slot position where the module is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid. For the Vmux2100 Main Board notApplicable (1) is used.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), clA(3), clB(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExPh1MlPrtIdx 1.3.6.1.4.1.164.3.2.3.2.2.1.1.3
This attribute indicates a unique port number. MP-2100/2200: MTML-1/E1 and MTML-1/T1 cards have only one external interface. inPrt1, inPrt2 - for MTML-H/2E1 and HSH cards. inPrt1..inPrt4 - for MTML-E2 and MSL-4 cards. exPrt2..exPrt4 - for MTML-4 cards and others exPrt1..exPrt8 - for ML-8 cards. inPrt1..inPrt8 - for MSL-8 and VF-30 card family. MP-104/204: only exPrt3 (3) is applicable. MP-4100: intPrt1...intPrt84 - for CLX cards. For other products' index see their specification.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6), exPrt7(7), exPrt8(8), exPrt9(9), exPrt10(10), exPrt11(11), exPrt12(12), exPrt13(13), exPrt14(14), exPrt15(15), exPrt16(16), exPrt17(17), exPrt18(18), inPrt1(101), inPrt2(102), inPrt3(103), inPrt4(104), inPrt5(105), inPrt6(106), inPrt7(107), inPrt8(108), inPrt9(109), inPrt10(110), inPrt11(111), inPrt12(112), inPrt13(113), inPrt14(114), inPrt15(115), inPrt16(116), inPrt17(117), inPrt18(118), inPrt19(119), inPrt20(120), inPrt21(121), inPrt22(122), inPrt23(123), inPrt24(124), inPrt25(125), inPrt26(126), inPrt27(127), inPrt28(128), inPrt29(129), inPrt30(130), inPrt31(131), inPrt32(132), inPrt33(133), inPrt34(134), inPrt35(135), inPrt36(136), inPrt37(137), inPrt38(138), inPrt39(139), inPrt40(140), inPrt41(141), inPrt42(142), inPrt43(143), inPrt44(144), inPrt45(145), inPrt46(146), inPrt47(147), inPrt48(148), inPrt49(149), inPrt50(150), inPrt51(151), inPrt52(152), inPrt53(153), inPrt54(154), inPrt55(155), inPrt56(156), inPrt57(157), inPrt58(158), inPrt59(159), inPrt60(160), inPrt61(161), inPrt62(162), inPrt63(163), inPrt64(164), inPrt65(165), inPrt66(166), inPrt67(167), inPrt68(168), inPrt69(169), inPrt70(170), inPrt71(171), inPrt72(172), inPrt73(173), inPrt74(174), inPrt75(175), inPrt76(176), inPrt77(177), inPrt78(178), inPrt79(179), inPrt80(180), inPrt81(181), inPrt82(182), inPrt83(183), inPrt84(184)  

prtExPh1MlConnect 1.3.6.1.4.1.164.3.2.3.2.2.1.1.4
This attribute indicates whether the port should be considered in any of the mux algorithms. It also affects all the card considerations because it may indicate that the module has only one physical interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtExPh1MlLineType 1.3.6.1.4.1.164.3.2.3.2.2.1.1.5
This attribute is the line type parameter for T1/E1 interface. The user should select only the values which are relevant to the specific port: (2),(3), (8) - for T1 port (4)..(7), (9) - for E1 port. (101) framed - This value does not exist in standard MIB and is used for a non-standard E1 port that doesn't has real framer. Note: for old devices, g732unframed(8) was used as E1 Unframed. That was because at the time this value did not exist in the standard MIB (RFC-1406), so we added it in private MIB. Now that it was added to standard MIB, private MIB was updated as well. This parameter has the same values as dsx1LineType in DS1 MIB (RFC-3895). The parameters in dsx1LineType are: other (1) esfT1 dsx1ESF (2) sfT1 dsx1D4 (3) g732nE1 dsx1E1 (4) g732nE1CRC dsx1E1-CRC (5) g732sE1 dsx1E1-MF (6) g732sE1CRC dsx1E1-MF-CRC (7) g732unframed dsx1Unframed (8) --from RFC-3895 e1Unframed dsx1E1Unframed (9) --from RFC-3895
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER esfT1(2), sfT1(3), g732nE1(4), g732nE1CRC(5), g732sE1(6), g732sE1CRC(7), g732unframed(8), e1Unframed(9), framed(101)  

prtExPh1MlLineCode 1.3.6.1.4.1.164.3.2.3.2.2.1.1.6
This attribute is the line code parameter used for T1/E1 interface. The user should select only the parameters which are relevant to the specific card: T1 line code parameters for MPH.1/T1 E1 line code parameters for MPH.1/E1. This parameter has the same values as dsx1LineCoding in T1/E1 MIB (RFC-1406). The parameters in dsx1LineCoding are: dsx1JBZS (1) dsx1B8ZS (2) dsx1HDB3 (3) dsx1ZBTSI (4) dsx1AMI (5) other (6)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER b7T1(1), b8zsT1(2), transT1(3), hdb3E1(4), notApplicable(255)  

prtExPh1MlLineLen 1.3.6.1.4.1.164.3.2.3.2.2.1.1.7
This attribute is the line length parameter used only for T1/DSU interfaces. lenXXXpXXXft = len-XXX-XXXft.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), len0p133ft(2), len134p266ft(3), len267p399ft(4), len400p533ft(5), len534p655ft(6), lenFcc68(7), notApplicable(255)  

prtExPh1MlRestoreTime 1.3.6.1.4.1.164.3.2.3.2.2.1.1.8
The time passing from the disappearance of the loss of synchronization condition (red alarm) to the restoration of normal service. The options 1secFast(2) and 10sec62411(3) for E1 interfaces are proprietary implementation of the T1 standard to the E1 interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER restoreT1secFast(2), restoreT10sec62411(3), ccittE1(4)  

prtExPh1MlTxGain 1.3.6.1.4.1.164.3.2.3.2.2.1.1.9
This attribute is the tx gain parameter used only for T1/CSU interfaces.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), txGain0db(2), txGain7dot5db(3), txGain15db(4), txGain22dot5db(5)  

prtExPh1MlRxSensitivity 1.3.6.1.4.1.164.3.2.3.2.2.1.1.10
This attribute is the rx line sensitivity parameter. low26dBm, high36dBm - applicable for T1-CSU shortHaul, longHaul - applicable for MTML-4 cards low15dbm was added for vmux110/210 T1 ports.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), low26dBm(2), high36dBm(3), shortHaul(4), longHaul(5), low15dbm(6)  

prtExPh1MlIdleCode 1.3.6.1.4.1.164.3.2.3.2.2.1.1.11
Determines the code for transmission in empty time slots. Type value(00-FFH), Excluding 0H,8H,10H,12H,21H,24H,42H,49H, 84H,92H
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtExPh1MlTdmTrunk 1.3.6.1.4.1.164.3.2.3.2.2.1.1.12
This attribute indicates whether the port is used to transfer TDM cards data and through which Bus.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER linkA(1), linkB(2), none(3), notApplicable(255)  

prtExPh1MlClkMode 1.3.6.1.4.1.164.3.2.3.2.2.1.1.13
Defines the clock operation mode of the T1/E1 interface. Ports that are connected to the TDM Buses must be in nodalTiming(3) clock mode.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER internalLocal(1), loopBackLocal(2), nodalTiming(3), loopBackFromLink(4), loopBackFromChannel(5), loopbackFromSystem(6)  

prtExPh1MlMfClkSrcSlt 1.3.6.1.4.1.164.3.2.3.2.2.1.1.14
This attribute indicates whether the port Tx multiframe is synchronized with Rx multiframe of another port and the slot position of that port. This operation is required in order to bypass signaling of PCM voice channels. Its value is always local(2) when the port isn't connected to any TDM bus. When it's value is local(2) there is no meaning to 'prtExPh1MlMfClkSrcPrt' parameter. In the ?004 Unit the entries io6(10)..io16) are not valid
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), local(2), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExPh1MlMfClkSrcPrt 1.3.6.1.4.1.164.3.2.3.2.2.1.1.15
A unique number to identify a port position in the mux. It has no effect when the prtExPh1MlMfClkSrcSlt selected is Local. inPrt1 - for MTML-H/E1 cards.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), inPrt1(101), notApplicable(255)  

prtExPh1MlFdlType 1.3.6.1.4.1.164.3.2.3.2.2.1.1.16
A unique number to identify the side of the FDL operation. Normal: 'response' for the user side and 'command' for the PTT side. Applicable only when working with ESF-T1 link
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), response(2), command(3)  

prtExPh1MlInbandMng 1.3.6.1.4.1.164.3.2.3.2.2.1.1.17
A unique number to identify an Inband management over the link.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), fdlOrTs0(3), dedicatedTs(4), dedicatedPpp(5), dedicatedFr(6), notApplicable(255)  

prtExPh1MlInbandMngRate 1.3.6.1.4.1.164.3.2.3.2.2.1.1.18
A unique number to identify the rate of the Inband management (Kbps). E1 port - it is not applicable when prtExPh1MlInbandMng selected is off. T1 port - it is not applicable when prtExPh1MlInbandMng selected is off OR fdlOrTs0.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), r4k(2), r8k(3), r12k(4), r16k(5), r32k(6), r64k(7), r20k(8)  

prtExPh1MlRedundType 1.3.6.1.4.1.164.3.2.3.2.2.1.1.19
This object determines the ML redundancy type: none - no ML redundacy dualCableAIS - each ML card is connected by a separate dualCableParallelTx cable to the other MUX (two cables connect two MUXes). There are two types of dual redundancy. yCable - Y cable is connected to both ML cards (one cable connects two MUXes). Default=none When only one ML card exists, the type can be only 'none'. The value should be the same for both ML slots.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), dualCableAIS(2), yCable(3), dualCableParallelTx(4)  

prtExPh1MlRedundSlot 1.3.6.1.4.1.164.3.2.3.2.2.1.1.20
This object indicates the slot containing the redundacy ML card, coupled with the current ML (prtExPh1MlSltIdx). When prtExPh1MlRedundType=none (no ML redundancy) this object will be 'notApplicable'. In the ?004 Unit the entries io6(10)..io12(16) are not valid When value is not 'none', it should be mutual to the redundant ML slot.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExPh1MlRedundPort 1.3.6.1.4.1.164.3.2.3.2.2.1.1.21
This object indicates the redundacy ML port, coupled with the current ML port (prtExPh1MlPrtIdx). When prtExPh1MlRedundType=none (no ML redundancy) this object will be 'notApplicable'. When value is not 'none', it should be mutual to the redundant ML port. inPrt1 - for MTML-H/E1 cards. inPrt1..inPrt4 - for MTML-E2 cards. exPrt2..exPrt4 - for MTML-4 cards.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), inPrt1(101), inPrt2(102), inPrt3(103), inPrt4(104), notApplicable(255)  

prtExPh1MlRedundRecTime 1.3.6.1.4.1.164.3.2.3.2.2.1.1.22
Redundancy Recovery Time (sec). After switching the ML card to the current (prtExPh1MlSltIdx), the next ML switch can be performed only after a minimum time, indicated by this object.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..99  

prtExPh1MlInbandMngRoutProt 1.3.6.1.4.1.164.3.2.3.2.2.1.1.23
This attribute indicates the Inband Mng routing protocol of the port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), rip2(2), proprietary(3), proprietaryNoNmsTx(4)  

prtExPh1MlIfType 1.3.6.1.4.1.164.3.2.3.2.2.1.1.24
Interface type of the port. For T1 - csu, dsu are the valid values For E1 - dsu, ltu are the valid values.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), csu(2), dsu(3), ltu(4)  

prtExPh1MlMultiplier 1.3.6.1.4.1.164.3.2.3.2.2.1.1.25
The data rate of each TS. The multiplier values can be 56 kbps or 64 kbps.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), br56(2), br64(3)  

prtExPh1MlSupportedTS 1.3.6.1.4.1.164.3.2.3.2.2.1.1.26
Number of Supported Time Slots by the agent. For Vmux-110 there is HW that supports less than 31/24 Time Slots for the E1/T1 port.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtExPh1MlImpedance 1.3.6.1.4.1.164.3.2.3.2.2.1.1.27
The Line Impedance. For T1 (always balanced), impedance is 100 ohm. For E1: - balanced = 120 ohm - unbalanced = 75 ohm.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), unbalanced(2), balanced(3)  

prtExPh1MlQ50BwControl 1.3.6.1.4.1.164.3.2.3.2.2.1.1.28
This object enables configuration of Q.50 Bandwidth Control on the port. If the bandwidth exceeds a certain threshold it is possible to disable new calls in the PBX via Q.50 protocol. Q.50 supports only E1 ports with Line Types: E1-MF (G.732S), E1-CRC-MF(G.732SCRC ) It does not support T1 ports. Annex A - the basic type of Q.50 which focuses only on the bandwidth control. Can use one of the following pairs of signaling bits: A&B or C&D. Annex B - Expansion of Annex A which includes also call release messages and Maintenance Messages. Uses A&B bits only.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(2), annexA(3), annexB(4)  

prtExPh1MlQ50SignalPair 1.3.6.1.4.1.164.3.2.3.2.2.1.1.29
Q.50 Signaling bits Pair that is currently in use: A&B bits or C&D bits. For Annex B it will always be: aAndB (2).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), aAndB(2), cAndD(3)  

prtExPh1MlInternalSwitch 1.3.6.1.4.1.164.3.2.3.2.2.1.1.30
This parameter shows whether the data will be transferred from one port to the other port within the same group of 2 ports. The default value is: Enable. Disable value might be necessary for security implementations or for ring applications. For Vmux-2100 device this parameter is used on the Channelized Cards. Both ports in each group should have the same value for this parameter.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(2), enable(3)  

prtExPh1MlSigService 1.3.6.1.4.1.164.3.2.3.2.2.1.1.31
Signaling Service given by this link. notApplicable - for T1 links normal - usual Signaling advanced - V5 Signaling.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), normal(2), advanced(3)  

prtExPh1MlFragmentSize 1.3.6.1.4.1.164.3.2.3.2.2.1.1.32
This parameter indicates the maximum number of bytes permitted in a packet send over the Link. Exceeding this size will cause packet fragmentation.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtExPh1MlTsTable 1.3.6.1.4.1.164.3.2.3.2.2.2
The write operation into the Table Objects is valid only to the TmpCnfg entry, except prtExPh1MlTsTest that will be written directly to the Active Configuration.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExPh1MlTsEntry

prtExPh1MlTsEntry 1.3.6.1.4.1.164.3.2.3.2.2.2.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtExPh1MlTsEntry  

prtExPh1MlTsCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.2.2.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

prtExPh1MlTsSltIdx 1.3.6.1.4.1.164.3.2.3.2.2.2.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid. For the Vmux2100 Main Board notApplicable (255) is used.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtExPh1MlTsPrtIdx 1.3.6.1.4.1.164.3.2.3.2.2.2.1.3
This attribute indicates a unique port number. MPH.1/E1 and MPH.1/T1 cards have only one external interface. exPrt2 - for ME1-2, MT1-2 and mhsPri cards. exPrt3, exPrt4 - for mhsPri cards. inPrt1 - for MTML-H/E1 cards.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6), exPrt7(7), exPrt8(8), exPrt9(9), exPrt10(10), exPrt11(11), exPrt12(12), exPrt13(13), exPrt14(14), exPrt15(15), exPrt16(16), exPrt17(17), exPrt18(18), inPrt1(101), inPrt2(102), inPrt3(103), inPrt4(104), inPrt5(105), inPrt6(106), inPrt7(107), inPrt8(108), inPrt9(109), inPrt10(110), inPrt11(111), inPrt12(112), inPrt13(113), inPrt14(114), inPrt15(115), inPrt16(116), inPrt17(117), inPrt18(118), inPrt19(119), inPrt20(120)  

prtExPh1MlTsIdx 1.3.6.1.4.1.164.3.2.3.2.2.2.1.4
This attribute indicates a unique time slot position. The valid time slots are 1..24 for T1 Card and 1..31 for E1 interface. In G732S-E1 lines time slot 16 is not valid for data, it is dedicated for multiframe synchronization bits and voice signaling.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtExPh1MlTsIConSlot 1.3.6.1.4.1.164.3.2.3.2.2.2.1.5
This attribute indicates whether the specified time slot is connected/routed internally in the Agent and to which card it is connected. In the ?004 Unit the entries io6(10)..io16) are not valid. split - will be used when the Src TS is connected to more than one slot OR more than one port (each needing less than a whole TS).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), noConnect(2), split(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtExPh1MlTsIConPrt 1.3.6.1.4.1.164.3.2.3.2.2.2.1.6
This attribute indicates the internally (In Mux) connected/routed port. For MP, the values will be: { exPrt1 (1) , exPrt2 (2) , exPrt3 (3) , exPrt4 (4) , exPrt5 (5) , exPrt6 (6) , exPrt7 (7) , exPrt8 (8) , exPrt9 (9) , exPrt10 (10) , exPrt11 (11) , exPrt12 (12) , noConnect (100), inPrt1 (101) , inPrt2 (102) , inPrt3 (103) , inPrt4 (104) , inPrt5 (105) , inPrt6 (106) , inPrt7 (107) , inPrt8 (108) , inPrt9 (109) , inPrt10 (110) , inPrt11 (111) , inPrt12 (112) } For other products see specific values at spec.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtExPh1MlTsIConTs 1.3.6.1.4.1.164.3.2.3.2.2.2.1.7
This attribute indicates a unique time slot position. The valid time slots are 1..24 for T1 Card and 1..31 for E1 interface. In G732S-E1 lines time slot 16 is not valid for data, it is dedicated to multiframe synchronization and voice signaling.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtExPh1MlTsExt 1.3.6.1.4.1.164.3.2.3.2.2.2.1.8
A pointer to an extension of this table: prtExTsSplitTable. - If prtExPh1MlTsIConSlot='split', its value should be set to the OBJECT IDENTIFIER of the prtExTsSplitTable, with its relevant CnfgIdx, SltIdx, PrtIdx, TsIdx and 1st TsBit. - If prtExPh1MlTsIConSlot is not 'split', its value should be set to the OBJECT IDENTIFIER { 0 0 }.
Status: current Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

prtExPh1MlTsTest 1.3.6.1.4.1.164.3.2.3.2.2.2.1.9
This attribute indicates a test to be activated on the selected TS. It is applicable only when prtSTstCmd=testPerTS(31). notApplicable - when prtSTstCmd is NOT testPerTS(31). none - no test is applied for the selected TS. split - when the tests are per Bit of the selected TS.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), localLoop(2), remoteLoop(3), remoteBert(8), localToneInjection(9), remoteToneInjection(18), localBert(30), split(254), notApplicable(255)  

prtExPh1MlTsType 1.3.6.1.4.1.164.3.2.3.2.2.2.1.10
The Time Slot Type. Transparent - means that the Time Slot will be Rx/Tx as is without processing it. If the device requires more than 1 unique data or ss7 Time Slot, options with numbers can be used like: data...data4. Each numbered Type can go to a different destination. ss7n2 - means the 2nd group of ss7 Time Slots. data2,data3, data4 mean group 2,3,4 of Data Time Slots. subCh1...subCh8 mean Sub Channel 1...8, respectively. trau, qmux, dynamic, signaling - are used by GSM devices.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noConnect(2), data(3), voice(4), cas(5), ss7(6), transparent(7), data2(8), data3(9), data4(10), ss7n2(11), hdlcV2Compatible(12), subCh1(13), subCh2(14), subCh3(15), subCh4(16), subCh5(17), subCh6(18), subCh7(19), subCh8(20), trau(21), qmux(22), dynamic(23), signaling(24), notApplicable(255)  

prtExPh1MlTsBundle 1.3.6.1.4.1.164.3.2.3.2.2.2.1.11
The number of the bundle containing this Time Slot. If no bundle exists for this TS or the bundle number is irrelevant, the value will be 0.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtExPh1MlTsTestDuration 1.3.6.1.4.1.164.3.2.3.2.2.2.1.12
This attribute indicates the maximum duration of executing a test on the specific TS. This entry applies to all the test operations. For the Vmux2100 the values are: 0 - 60 seconds. A zero value specifies no time limitation. When the test isn't active, the agent initiates this object to 2 when the duration is needed and to 0 if its not required. The user should set this parameter after setting the 'prtExPh1MlTsTest' parameter.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtExPh1MlTsSubChType 1.3.6.1.4.1.164.3.2.3.2.2.2.1.13
The Time Slot Sub-Channel Type. This variable is relevant only when Time-Slot Type is SubCh (e.g. prtExPh1MlTsType = subCh1...subCh8).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER hdlc(1), transparent(2), notApplicable(255)  

prtExPh1MlTsSubChMask 1.3.6.1.4.1.164.3.2.3.2.2.2.1.14
The Sub-Channel Type Mask. This variable is relevant only when Time-Slot Type is SubCh (e.g. prtExPh1MlTsType = subCh1...subCh8).
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtExPh1MlTsChRate 1.3.6.1.4.1.164.3.2.3.2.2.2.1.15
The Rate of the Signaling Channel. notApplicable(1) when TS Type is other than Signaling or Transparent
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), r16Kbps(2), r32Kbps(3), r64Kbps(4), r8Kbps(5), auto(6)  

prtExPh1MlTsByteReversal 1.3.6.1.4.1.164.3.2.3.2.2.2.1.16
Byte Reversal. This variable defines whether the LSB or MSB is transmitted first. no(2) - MSB is transmitted first yes(3) - LSB is transmitted first.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

prtExPh1MlTsSigProfile 1.3.6.1.4.1.164.3.2.3.2.2.2.1.17
This object indicates the Signaling Profile of the port. It is applicable only when prtMl4SigProfile=perTS. p1 = profile 1 p2 = profile 2 p3 = profile 3 p4 = profile 4 p5 = profile 5
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), p1(3), p2(4), p3(5), p4(6), p5(7)  

prtInPh1MlCnfgTable 1.3.6.1.4.1.164.3.2.3.2.2.3
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtInPh1MlCnfgEntry

prtInPh1MlCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.2.3.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtInPh1MlCnfgEntry  

prtInPh1MlCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.2.3.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

prtInPh1MlSltType 1.3.6.1.4.1.164.3.2.3.2.2.3.1.2
This attribute indicates a unique slot position where the card is inserted. For ISDN BRI port of MX300/30: io1(5) = isdn1(5) and io2(6) = isdn2(6) In the ?004 Unit the entries io6(10)..io12(16) are not valid
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtInPh1MlPrtIdx 1.3.6.1.4.1.164.3.2.3.2.2.3.1.3
This attribute indicates a unique port number. MPH.1/E1 and MPH.1/T1 cards have three internal interfaces. MX3000 modules may have up to 50 internal ports.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtInPh1MlConnect 1.3.6.1.4.1.164.3.2.3.2.2.3.1.4
This attribute indicates whether the port should be considered in any of the mux algorithms.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtInPh1MlRate 1.3.6.1.4.1.164.3.2.3.2.2.3.1.5
This attribute indicates the port speed.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER r1x56eq56Kbps(1), r1x64eq64Kbps(2), r2x56eq112Kbps(3), r2x64eq128Kbps(4), r3x56eq168Kbps(5), r3x64eq192Kbps(6), r4x56eq224Kbps(7), r4x64eq256Kbps(8), r5x56eq280Kbps(9), r5x64eq320Kbps(10), r6x56eq336Kbps(11), r6x64eq384Kbps(12), r7x56eq392Kbps(13), r7x64eq448Kbps(14), r8x56eq448Kbps(15), r8x64eq512Kbps(16), r9x56eq504Kbps(17), r9x64eq576Kbps(18), r10x56eq560Kbps(19), r10x64eq640Kbps(20), r11x56eq616Kbps(21), r11x64eq704Kbps(22), r12x56eq672Kbps(23), r12x64eq768Kbps(24), r13x56eq728Kbps(25), r13x64eq832Kbps(26), r14x56eq784Kbps(27), r14x64eq896Kbps(28), r15x56eq840Kbps(29), r15x64eq960Kbps(30), r16x56eq896Kbps(31), r16x64eq1024Kbps(32), r17x56eq952Kbps(33), r17x64eq1088Kbps(34), r18x56eq1008Kbps(35), r18x64eq1152Kbps(36), r19x56eq1064Kbps(37), r19x64eq1216Kbps(38), r20x56eq1120Kbps(39), r20x64eq1280Kbps(40), r21x56eq1176Kbps(41), r21x64eq1344Kbps(42), r22x56eq1232Kbps(43), r22x64eq1408Kbps(44), r23x56eq1288Kbps(45), r23x64eq1472Kbps(46), r24x56eq1344Kbps(47), r24x64eq1536Kbps(48), r25x56eq1400Kbps(49), r25x64eq1600Kbps(50), r26x56eq1456Kbps(51), r26x64eq1664Kbps(52), r27x56eq1512Kbps(53), r27x64eq1728Kbps(54), r28x56eq1568Kbps(55), r28x64eq1792Kbps(56), r29x56eq1624Kbps(57), r29x64eq1856Kbps(58), r30x56eq1680Kbps(59), r30x64eq1920Kbps(60), r31x56eq1736Kbps(61), r31x64eq1984Kbps(62), r32x56eq1792Kbps(63), r32x64eq2048Kbps(64), r1x1dot5eq1dot5M(65), r2x1dot5eq3M(66), r3x1dot5eq4dot5M(67), r4x1dot5eq6M(68), r5x1dot5eq7dot5M(69), r6x1dot5eq9M(70), r7x1dot5eq10dot5M(71), r8x1dot5eq12M(72), r1x2Meq2M(73), r2x2Meq4M(74), r3x2Meq6M(75), r4x2Meq8M(76), r5x2Meq10M(77), r6x2Meq12M(78), r7x2Meq14M(79), r8x2Meq16M(80), noRate(100)  

prtInPh1MlProtocol 1.3.6.1.4.1.164.3.2.3.2.2.3.1.6
This attribute indicates the applied protocol.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER fr(1), frPlus(2), pCellRelay(3), hdlcSdlc(4), transparentHdlc(5), ciscoBridgedEth(6)  

prtInPh1MlConnectionTyp 1.3.6.1.4.1.164.3.2.3.2.2.3.1.7
This attribute indicates the link connection type. It is required for three reasons: FR/CR Inband management operation (LMI,CLMM...). CIR check. NMS network management. SameNetManaged - indicates network internal line. SameNetNotMana - indicates network internal line, but the remote mux is not managed by the nms. User - User to Network Interface. OtherNet - Network To Network Interfce. PubNet - Access Mux To PubNet Interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER sameNetManaged(1), sameNetNotMana(2), user(3), otherNet(4), pubNet(5), notApplicable(255)  

prtInPh1MlCongResponse 1.3.6.1.4.1.164.3.2.3.2.2.3.1.8
This attribute indicates how to handle the congestion indication to/from the mux internal connection side (for example transmit/receive becn to/from the network). no - do nothing FlowControl - translate the congestion indication between the port and the internal connection port according to the definition of the prtInPh1MlFlowControl parameters. The operation is done in both directions.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER no(2), flowControl(3)  

prtInPh1MlCongLevel 1.3.6.1.4.1.164.3.2.3.2.2.3.1.9
This attribute indicates the level of delayed data in precents of the total available dynamic memory, for which the port will start to operate . The resolution of the parameter is 5 percent. Valid values: 10..70, 255. 255=notApplicable.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtInPh1MlTc 1.3.6.1.4.1.164.3.2.3.2.2.3.1.10
This attribute indicates the Tc parameter which is the time period of the sliding window in which the Bc/Be are tested. The value of this parameter is identical for all the ports in the specific card. 255=notApplicable.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER tc1sec(1), tc2sec(2), tc3sec(3), tc4sec(4), notApplicable(255)  

prtInPh1MlFlowControl 1.3.6.1.4.1.164.3.2.3.2.2.3.1.11
This attribute indicates the required flow control betweeen the port and the remote equipment.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(2), fecnBecn(3)  

prtInPh1MlSegment 1.3.6.1.4.1.164.3.2.3.2.2.3.1.12
This object is the Segmentation in Bytes. In protocol FR+, ISDN internals, MX 30/300 the segmentation is: 50 (2) ,158 (3) ,266 (4) ,376 (5), 484 (6) In MX 3000/4: For protocol FR+ (internal ISDN ports of MHS.S, MHS.U, MHS.E1, MHS.T1 cards) segmentation values are: 236 (7),472 (8), 708 (9), 944 (10) ,1180 (11)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), s36Byte(2), s150Byte(3), s264Byte(4), s378Byte(5), s492Byte(6), s236Byte(7), s472Byte(8), s708Byte(9), s944Byte(10), s1180Byte(11)  

prtInPh1MlFrMngProt 1.3.6.1.4.1.164.3.2.3.2.2.3.1.13
This object indicates the Frame-Relay management protocol. ansiT1 = ANSI T1.617 Annex D (this is the default value). This parameter is applicable only for FR and FR+ protocols. When prtInPh1MlConnectionTyp = sameNetManaged, this object will be RO (internally determined).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), none(2), lmi(3), ansiT1(4), annexA(5)  

prtInPh1MlEnqPeriod 1.3.6.1.4.1.164.3.2.3.2.2.3.1.14
This object is the Status Enquiry Period, in seconds. It determines the frequency of the Status Enquiry message as sent by the FR user side. At the FR network side, it determines the timeout for this message reception. Default = 4 seconds. This parameter is applicable only for FR and FR+ protocols AND only when prtInPh1MlFrMngProt is NOT (notApplicable or none). 0=notApplicable.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..30  

prtInPh1MlFullRptPeriod 1.3.6.1.4.1.164.3.2.3.2.2.3.1.15
This object is the Full Report Frequency. It determines the number of the Status Enquiry messages sent by the FR user side, before a Full Report Request is sent. The units are : Status Enquiry messages (periods). Valid values: 1 .. 255. 255 = infinite (never sent). This parameter is applicable only for FR and FR+ protocols AND only when prtInPh1MlFrMngProt is NOT (notApplicable or none). 0=notApplicable.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..255  

prtInPh1MlFrWindowSize 1.3.6.1.4.1.164.3.2.3.2.2.3.1.16
This object is the FR Window Size. It determines the number of samplings in the sliding window that counts the errors. This parameter is applicable only for FR and FR+ protocols AND only when prtInPh1MlFrMngProt is NOT (notApplicable or none). 0=notApplicable.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..10  

prtInPh1MlErrorsThreshold 1.3.6.1.4.1.164.3.2.3.2.2.3.1.17
This object is the Max Errors. It determines the number of Status Enquiry Errors that occured within the FR sliding window, before this port is considered DOWN (threshold). This parameter is applicable only for FR and FR+ protocols AND only when prtInPh1MlFrMngProt is NOT (notApplicable or none). 0=notApplicable.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..10  

prtInPh1MlMaxIdleTime 1.3.6.1.4.1.164.3.2.3.2.2.3.1.18
Move to higher prioritized connected link after this period of seconds of silence on the current link. 0=Never. Never move to higher prioritized connected link. UNIT is seconds. Valid values are: 0, 1, 2, 3, 4, 5, 10, 20, 30, 40, 50, 60, 120, 180, 240, 300, 360, 420, 480, 540, 600, 900, 1200, 1500, 1800. Attempt to Set an invalid value will result in getting the default value.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..1800  

prtInPh1MlBearerCh 1.3.6.1.4.1.164.3.2.3.2.2.3.1.19
Defines which B (bearer) channels are used for transferring ISDN data. Default value is: none (255). anyChannel (2) is skipped because it is not in use here.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), channelB1(3), channelB2(4), chB1andchB2(5), none(255)  

prtInPh1MlAssociatedExCh 1.3.6.1.4.1.164.3.2.3.2.2.3.1.20
This object indicates the external port associated to this internal port. At present, it is used by the Hybrid (mp2100h), MHS-4 cards which can have up to 64 dynamic internal ports associated with External ports. For ISDN cards, the value will be: notApplicable (255). The associated external of an ISDN internal port is represented by the MIB object: prtIsdnDirectoryPrtNu.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), notApplicable(255)  

prtInPh1MlClockEncoding 1.3.6.1.4.1.164.3.2.3.2.2.3.1.21
This object is the Encoding type of the Line. This parameter is applicable only for FR and FR+ protocols.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), nrz(2), nrzI(3), fm0(4), manchester(5), diffManchester(6)  

prtInPh1MlMinSeparators 1.3.6.1.4.1.164.3.2.3.2.2.3.1.22
Minimum number of bytes separating between two adjacent frames (HDLC item). 0 = notApplicable
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..16  

prtInPh1MlCcittCrc 1.3.6.1.4.1.164.3.2.3.2.2.3.1.23
This object indicates how many Bits are used for CRC (HDLC item).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), crc16(2), crc32(3)  

prtInPh1MlFrameSeparator 1.3.6.1.4.1.164.3.2.3.2.2.3.1.24
This object indicates what should be transferred on the line when there are no frames to pass (HDLC item). idles: mean that FF will pass on the line flags: mean that 7E will pass on the line.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), idles(2), flags(3)  

prtInPh1MlDlciTable 1.3.6.1.4.1.164.3.2.3.2.2.4
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtInPh1MlDlciEntry

prtInPh1MlDlciEntry 1.3.6.1.4.1.164.3.2.3.2.2.4.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtInPh1MlDlciEntry  

prtInPh1MlDlciCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.2.4.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

prtInPh1MlDlciSltIdx 1.3.6.1.4.1.164.3.2.3.2.2.4.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtInPh1MlDlciPrtIdx 1.3.6.1.4.1.164.3.2.3.2.2.4.1.3
This attribute indicates a unique internal port number. MPH.1/E1 and MPH.1/T1 cards have three internal ports.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER inPrt1(101), inPrt2(102), inPrt3(103)  

prtInPh1MlDlciIdx 1.3.6.1.4.1.164.3.2.3.2.2.4.1.4
This attribute indicates a unique index for each possible used dlci(16..991). When the protocol is not Multiplexing protocol, then its type is 'user' and the only valid index is 1.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..991  

prtInPh1MlDlciValid 1.3.6.1.4.1.164.3.2.3.2.2.4.1.5
This attribute indicates whether the attributes in this entry are valid or not. The user can add/delete pvc (dlci to dlci connection) by modifing this object
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtInPh1MlDlciIConSlt 1.3.6.1.4.1.164.3.2.3.2.2.4.1.6
This attribute indicates a unique slot position In the Mux (Agent) where the dlci is routed to. In the ?004 Unit the entries io6(10)..io16) are not valid
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noConnect(2), cl(3), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtInPh1MlDlciIConPrt 1.3.6.1.4.1.164.3.2.3.2.2.4.1.7
This attribute indicates a unique port id which the dlci is routed to.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6), exPrt7(7), exPrt8(8), exPrt9(9), exPrt10(10), clNMS(99), noConnect(100), inPrt1(101), inPrt2(102), inPrt3(103), inPrt4(104), inPrt5(105), inPrt6(106), inPrt7(107), inPrt8(108), inPrt9(109), inPrt10(110), inPrt11(111), inPrt12(112)  

prtInPh1MlDlciIConDlci 1.3.6.1.4.1.164.3.2.3.2.2.4.1.8
This attribute indicates a unique internal connection dlci number which the src dlci is routed to.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..991  

prtInPh1MlDlciTxBc 1.3.6.1.4.1.164.3.2.3.2.2.4.1.9
This attribute indicates a unique Tx committed bandwidth on the user transmit line or at the port receive line.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER full(1), zero(2), txBc9600bps(3), txBc14200bps(4), txBc19200bps(5), txBc28800bps(6), txBc32000bps(7), txBc38400bps(8), txBc48000bps(9), txBc56000bps(10), txBc57600bps(11), txBc64Kbps(12), txBc128Kbps(13), txBc192Kbps(14), txBc256Kbps(15), txBc320Kbps(16), txBc384Kbps(17), txBc448Kbps(18), txBc512Kbps(19), txBc768Kbps(20), txBc1024Kbps(21)  

prtInPh1MlDlciTxBe 1.3.6.1.4.1.164.3.2.3.2.2.4.1.10
This attribute indicates a unique Tx excess bandwidth on the user transmit line or at the port receive line.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER full(1), zero(2), txBe9600bps(3), txBe14200bps(4), txBe19200bps(5), txBe28800bps(6), txBe32000bps(7), txBe38400bps(8), txBe48000bps(9), txBe56000bps(10), txBe57600bps(11), txBe64Kbps(12), txBe128Kbps(13), txBe192Kbps(14), txBe256Kbps(15), txBe320Kbps(16), txBe384Kbps(17), txBe448Kbps(18), txBe512Kbps(19), txBe768Kbps(20), txBe1024Kbps(21)  

prtInPh1MlDlciRxBc 1.3.6.1.4.1.164.3.2.3.2.2.4.1.11
This attribute indicates a unique Rx committed bandwidth on the user receive line or at the port transmit line.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER full(1), zero(2), rxBc9600bps(3), rxBc14200bps(4), rxBc19200bps(5), rxBc28800bps(6), rxBc32000bps(7), rxBc38400bps(8), rxBc48000bps(9), rxBc56000bps(10), rxBc57600bps(11), rxBc64Kbps(12), rxBc128Kbps(13), rxBc192Kbps(14), rxBc256Kbps(15), rxBc320Kbps(16), rxBc384Kbps(17), rxBc448Kbps(18), rxBc512Kbps(19), rxBc768Kbps(20), rxBc1024Kbps(21)  

prtInPh1MlDlciRxBe 1.3.6.1.4.1.164.3.2.3.2.2.4.1.12
This attribute indicates a unique Rx excess bandwidth on the user receive line or at the port transmit line.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER full(1), zero(2), rxBe9600bps(3), rxBe14200bps(4), rxBe19200bps(5), rxBe28800bps(6), rxBe32000bps(7), rxBe38400bps(8), rxBe48000bps(9), rxBe56000bps(10), rxBe57600bps(11), rxBe64Kbps(12), rxBe128Kbps(13), rxBe192Kbps(14), rxBe256Kbps(15), rxBe320Kbps(16), rxBe384Kbps(17), rxBe448Kbps(18), rxBe512Kbps(19), rxBe768Kbps(20), rxBe1024Kbps(21)  

prtInPh1MlDlciPriority 1.3.6.1.4.1.164.3.2.3.2.2.4.1.13
This attribute indicates a unique priority of the pcv. 1 is the lowest priority and 8 is the highest priority.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..8  

prtInPh1MlDlciStatus 1.3.6.1.4.1.164.3.2.3.2.2.4.1.14
This attribute indicates the status of the pvc. The status is disconnected(1) when one of the sides is programmed as not connected
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER disconnected(1), connected(2)  

prtPhMlCnfgTable 1.3.6.1.4.1.164.3.2.3.2.2.5
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtPhMlCnfgEntry

prtPhMlCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.2.5.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtPhMlCnfgEntry  

prtPhMlCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.2.5.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

prtPhMlSltIdx 1.3.6.1.4.1.164.3.2.3.2.2.5.1.2
This attribute indicates a unique slot position where the module is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid. For the Vmux2100 Main Board notApplicable (1) is used.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtPhMlPrtIdx 1.3.6.1.4.1.164.3.2.3.2.2.5.1.3
This attribute indicates a unique port number. ML-20 cards have just one external interface.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER exPrt1(1)  

prtPhMlConnect 1.3.6.1.4.1.164.3.2.3.2.2.5.1.4
This attribute indicates whether the port should be considered in any of the mux algorithms.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtPhMlRate 1.3.6.1.4.1.164.3.2.3.2.2.5.1.5
This attribute indicates the configured port speed. auto - rate is adapted automatically to the attached modem rate.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER r1x64eq64Kbps(2), r2x64eq128Kbps(4), r3x64eq192Kbps(6), r4x64eq256Kbps(8), r5x64eq320Kbps(10), r6x64eq384Kbps(12), r7x64eq448Kbps(14), r8x64eq512Kbps(16), r9x64eq576Kbps(18), r10x64eq640Kbps(20), r11x64eq704Kbps(22), r12x64eq768Kbps(24), r13x64eq832Kbps(26), r14x64eq896Kbps(28), r15x64eq960Kbps(30), r16x64eq1024Kbps(32), r17x64eq1088Kbps(34), r18x64eq1152Kbps(36), r19x64eq1216Kbps(38), r20x64eq1280Kbps(40), r21x64eq1344Kbps(42), r22x64eq1408Kbps(44), r23x64eq1472Kbps(46), r24x64eq1536Kbps(48), r25x64eq1600Kbps(50), r26x64eq1664Kbps(52), r27x64eq1728Kbps(54), r28x64eq1792Kbps(56), r29x64eq1856Kbps(58), r30x64eq1920Kbps(60), r31x64eq1984Kbps(62), r32x64eq2048Kbps(64), auto(70)  

prtPhMlCAS 1.3.6.1.4.1.164.3.2.3.2.2.5.1.6
This attribute indicates whether Channel Associated Signaling (CAS) is used.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtPhMlClockMode 1.3.6.1.4.1.164.3.2.3.2.2.5.1.7
Clock mode.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER dce(2), ext-dce(3), dte(4)  

prtPhMlSatBuffer 1.3.6.1.4.1.164.3.2.3.2.2.5.1.8
Satellite Buffer (+/- 256).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

prtPhMlDialProcess 1.3.6.1.4.1.164.3.2.3.2.2.5.1.9
Dial Process.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), callIn(3), callOut(4)  

prtPhMlSyncRestore 1.3.6.1.4.1.164.3.2.3.2.2.5.1.10
Sync Restoration time, in seconds. notApplicable=0.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..10  

prtPhMlBus 1.3.6.1.4.1.164.3.2.3.2.2.5.1.11
The TDM BUS this port is linked to.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), busA(2), busB(3)  

prtPhMlMfSyncSlot 1.3.6.1.4.1.164.3.2.3.2.2.5.1.12
This attribute indicates whether the sync is synchronized according to a certain card and the slot of this card. This operation is required in order to bypass signaling of PCM voice channels. In the ?004 Unit the entries io6(10)..io12(16) are not valid
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(2), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtPhMlClockSource 1.3.6.1.4.1.164.3.2.3.2.2.5.1.13
The Clock Source: TC (Tx Clock) or RC (Rx Clock) signals.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), txClock(2), rxClock(3)  

prtPhMlErrCorrection 1.3.6.1.4.1.164.3.2.3.2.2.5.1.14
This object indicates if Error Correction mechanism should be applied or not. It will be applicable only if the interface HW includes the Error Correction chip.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

prtPhMlCorrectionMode 1.3.6.1.4.1.164.3.2.3.2.2.5.1.15
This object is applicable only when prtPhMlErrCorrection=yes. random - enables to correct up to 3 random errors in an 23 bit frame built from 12 data bits and 11 appended parity bits. bursty - interleaving 3 frames, allows correcting bursts of 9 bit length.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), random(2), bursty(3)  

prtPhMlControlSignals 1.3.6.1.4.1.164.3.2.3.2.2.5.1.16
This object shows whether the Port will ignore or implement the control signals like DCD, CTS, DTR.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), ignore(2), implement(3)  

prtPhMlInterfaceType 1.3.6.1.4.1.164.3.2.3.2.2.5.1.17
The SW Configurable Interface Type.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), v35(2), x21(3), rs232(4), rs449(5), ei530(6), ei530a(7)  

prtPhMlClockPolarity 1.3.6.1.4.1.164.3.2.3.2.2.5.1.18
This object indicates the clock polarity.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), normal(2), inverted(3)  

prtLogicalCnfgTable 1.3.6.1.4.1.164.3.2.3.2.17.1
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtLogicalCnfgEntry

prtLogicalCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.17.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtLogicalCnfgEntry  

prtLogicalCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.17.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

prtLogicalSltIdx 1.3.6.1.4.1.164.3.2.3.2.17.1.1.2
Slot Index. For ISDN BRI Ports of MX300/30, io1(5) = isdn1(5) and io2(6) = isdn2(6).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtLogicalPrtIdx 1.3.6.1.4.1.164.3.2.3.2.17.1.1.3
This attribute indicates a unique port number. This port number should be an internal port number: inPrt1(101)->inPrt50(150), linkSel1(200)->linkSel50(250), encaps1(300)-> encaps50(350), huntGr1(101) -> huntGr10(110).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtLogicalConnect 1.3.6.1.4.1.164.3.2.3.2.17.1.1.4
This attribute indicates whether the port should be considered in any of the mux algorithms.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtLogicalFunction 1.3.6.1.4.1.164.3.2.3.2.17.1.1.5
This parameter defines the function of the relevant channel.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER notApplicable(1), linkSelector(2), encapsulator(3), huntGroup(4)  

prtLogicalRowStatus 1.3.6.1.4.1.164.3.2.3.2.17.1.1.6
This parameter allows the NMS to create/delete logical ports. The only possible supported RowStatus vaules are active (1) and destroy (6).
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

linkSelectorCnfgTable 1.3.6.1.4.1.164.3.2.3.2.17.2
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LinkSelectorCnfgEntry

linkSelectorCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.17.2.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  LinkSelectorCnfgEntry  

linkSelectorCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.17.2.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

linkSelectorSltIdx 1.3.6.1.4.1.164.3.2.3.2.17.2.1.2
Slot Index
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

linkSelectorPrtIdx 1.3.6.1.4.1.164.3.2.3.2.17.2.1.3
This attribute indicates a unique port number. This port number should be internal port number: higher or equal to linkSeL1(201).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

linkSelectorMaxIdleTime 1.3.6.1.4.1.164.3.2.3.2.17.2.1.4
Move to higher prioritized connected link after this period of seconds of silence on the current link. 0=move immediately to higher prioritized connected link. UNIT is seconds.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..255  

linkSelectorMode 1.3.6.1.4.1.164.3.2.3.2.17.2.1.5
If the link selector is in mode: backup(2)=then the link with the lower priority will be used in case of failure of the higher priority link, bod(3)=bandwidth on demand or dynamic bandwidth allocation means that links with lower priority will be used whenever additional bandwidth is required.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), backup(2), bod(3)  

linkSelectorRevert 1.3.6.1.4.1.164.3.2.3.2.17.2.1.6
If the link selector is in mode backup: auto(2)=return automatically to Main link when it is OK. manual(3)=stays connected to backup link.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), auto(2), manual(3)  

linkSelectorMinBUSession 1.3.6.1.4.1.164.3.2.3.2.17.2.1.7
Minimum duration of a backup session before returning to Main Link. Relevant in Backup Mode and when Revert is auto(2). Value 255 is for NEVER which means never return to Main Link. UNIT is minutes.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..255  

linkSelectorPLinkTable 1.3.6.1.4.1.164.3.2.3.2.17.3
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LinkSelectorPLinkEntry

linkSelectorPLinkEntry 1.3.6.1.4.1.164.3.2.3.2.17.3.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  LinkSelectorPLinkEntry  

pLinkCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.17.3.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

pLinkSltIdx 1.3.6.1.4.1.164.3.2.3.2.17.3.1.2
Slot Index
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

pLinkPrtIdx 1.3.6.1.4.1.164.3.2.3.2.17.3.1.3
This attribute indicates a unique port number. This port number should be the link selector number.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 200..250  

pLinkIdx 1.3.6.1.4.1.164.3.2.3.2.17.3.1.4
This index is the row number.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..8  

pLinkSlotNu 1.3.6.1.4.1.164.3.2.3.2.17.3.1.5
The slot of the prioritized link. For ISDN BRI ports of MX300/30, io1(5) = isdn1(5) and io2(6) = isdn2(6).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noConnect(2), cl(3), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

pLinkPortNu 1.3.6.1.4.1.164.3.2.3.2.17.3.1.6
The port of the prioritized link. Value 100 is for noConnect.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

pLinkPrioNu 1.3.6.1.4.1.164.3.2.3.2.17.3.1.7
The priority of the prioritized link. MIN=1...., MAX=8.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..8  

pLinkVRate 1.3.6.1.4.1.164.3.2.3.2.17.3.1.8
The rate to use with this link.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER r1x56eq56Kbps(1), r1x64eq64Kbps(2), r2x56eq112Kbps(3), r2x64eq128Kbps(4), r3x56eq168Kbps(5), r3x64eq192Kbps(6), r4x56eq224Kbps(7), r4x64eq256Kbps(8), r5x56eq280Kbps(9), r5x64eq320Kbps(10), r6x56eq336Kbps(11), r6x64eq384Kbps(12), r7x56eq392Kbps(13), r7x64eq448Kbps(14), r8x56eq448Kbps(15), r8x64eq512Kbps(16), r9x56eq504Kbps(17), r9x64eq576Kbps(18), r10x56eq560Kbps(19), r10x64eq640Kbps(20), r11x56eq616Kbps(21), r11x64eq704Kbps(22), r12x56eq672Kbps(23), r12x64eq768Kbps(24), r13x56eq728Kbps(25), r13x64eq832Kbps(26), r14x56eq784Kbps(27), r14x64eq896Kbps(28), r15x56eq840Kbps(29), r15x64eq960Kbps(30), r16x56eq896Kbps(31), r16x64eq1024Kbps(32), r17x56eq952Kbps(33), r17x64eq1088Kbps(34), r18x56eq1008Kbps(35), r18x64eq1152Kbps(36), r19x56eq1064Kbps(37), r19x64eq1216Kbps(38), r20x56eq1120Kbps(39), r20x64eq1280Kbps(40), r21x56eq1176Kbps(41), r21x64eq1344Kbps(42), r22x56eq1232Kbps(43), r22x64eq1408Kbps(44), r23x56eq1288Kbps(45), r23x64eq1472Kbps(46), r24x56eq1344Kbps(47), r24x64eq1536Kbps(48), r25x56eq1400Kbps(49), r25x64eq1600Kbps(50), r26x56eq1456Kbps(51), r26x64eq1664Kbps(52), r27x56eq1512Kbps(53), r27x64eq1728Kbps(54), r28x56eq1568Kbps(55), r28x64eq1792Kbps(56), r29x56eq1624Kbps(57), r29x64eq1856Kbps(58), r30x56eq1680Kbps(59), r30x64eq1920Kbps(60), r31x56eq1736Kbps(61), r31x64eq1984Kbps(62), noRate(100)  

prtExPhPlCnfgTable 1.3.6.1.4.1.164.3.2.3.2.3.1
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExPhPlCnfgEntry

prtExPhPlCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.3.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtExPhPlCnfgEntry  

prtExPhPlCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.3.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

prtExPhPlSltIdx 1.3.6.1.4.1.164.3.2.3.2.3.1.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtExPhPlPrtIdx 1.3.6.1.4.1.164.3.2.3.2.3.1.1.3
This attribute indicates a unique port number. In case of PH.1 card, only exPrt(1) is valid.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6)  

prtExPhPlConnect 1.3.6.1.4.1.164.3.2.3.2.3.1.1.4
This attribute indicates whether the port should be considered in any of the mux algorithms.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtExPhPlHRate 1.3.6.1.4.1.164.3.2.3.2.3.1.1.5
This attribute indicates the port speed for HIGH speed cards. The card has limitations about the maximum sigma channel speeds and about the possible rates for each clock mode . N - The rate is valid for DCE and EXT-DCE Nodal clock mode. L - The rate is valid for DCE and EXT-DCE Local clock mode. E - The rate is valid for DTE External clock mode. 'r9d6KbpsNLE' means rate of 9.6 Kbps ('d'=dot). Note: Some rate attributes have been changed. As the MIB was already released with the old attributes, the names of the options were not changed. The new names + attributes are in a comment. Example: r2048KbpsE (63), -- r2048KbpsNLE
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), r32KbpsNLE(2), r48KbpsNLE(3), r56KbpsNLE(4), r64KbpsNLE(5), r112KbpsNLE(6), r128KbpsNLE(7), r168KbpsNLE(8), r192KbpsNLE(9), r224KbpsNLE(10), r256KbpsNLE(11), r280KbpsE(12), r320KbpsE(13), r336KbpsNLE(14), r384KbpsNLE(15), r392KbpsE(16), r448KbpsNLE(17), r504KbpsLE(18), r512KbpsE(19), r560KbpsE(20), r576KbpsLE(21), r616KbpsE(22), r640KbpsE(23), r672KbpsNLE(24), r704KbpsE(25), r728KbpsE(26), r768KbpsNLE(27), r784KbpsE(28), r832KbpsE(29), r840KbpsE(30), r896KbpsNLE(31), r952KbpsE(32), r960KbpsE(33), r1008KbpsLE(34), r1024KbpsE(35), r1064KbpsE(36), r1088KbpsE(37), r1120KbpsE(38), r1152KbpsLE(39), r1176KbpsE(40), r1216KbpsE(41), r1232KbpsE(42), r1280KbpsE(43), r1288KbpsE(44), r1344KbpsNLE(45), r1400KbpsE(46), r1408KbpsE(47), r1456KbpsE(48), r1472KbpsE(49), r1512KbpsE(50), r1536KbpsE(51), r1568KbpsE(52), r1600KbpsE(53), r1624KbpsE(54), r1664KbpsE(55), r1680KbpsE(56), r1728KbpsE(57), r1736KbpsE(58), r1792KbpsNLE(59), r1856KbpsE(60), r1920KbpsE(61), r1984KbpsE(62), r2048KbpsE(63), r9d6KbpsNLE(65), r14d4KbpsNLE(66), r16KbpsNLE(67), r19d2KbpsNLE(68), r28d8KbpsNLE(69), r38d4KbpsNLE(70), r57d6KbpsNLE(71), r115d2KbpsNLE(72), r24000bps(73)  

prtExPhPlLRate 1.3.6.1.4.1.164.3.2.3.2.3.1.1.6
This attribute indicates the port speed for LOW speed cards. The card has limitations about the possible rates for each clock mode. N - The rate is valid for DCE and EXT-DCE Nodal clock mode. L - The rate is valid for DCE and EXT-DCE Local clock mode. E - The rate is valid for DTE External clock mode. Note: Some rate attributes have been changed. As the MIB was already released with the old attributes, the names of the options were not changed. The new names + attributes are in a comment. Example: r57600bpsLE (16), -- r57600bpsNLE
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), r300bpsNLE(2), r600bpsNLE(3), r800bpsNLE(4), r1200bpsNLE(5), r2400bpsNLE(6), r4800bpsNLE(7), r9600bpsNLE(8), r14400bpsLE(9), r19200bpsNLE(10), r28800bpsLE(11), r32000bpsNLE(12), r38400bpsNLE(13), r48000bpsNLE(14), r56000bpsNLE(15), r57600bpsLE(16), r64000bpsNLE(17), r112000bps(18), r115200bps(19), r16000bpsNLE(20), r100bpsNLE(21), r128000bps(22), r24000bps(23)  

prtExPhPlProtocol 1.3.6.1.4.1.164.3.2.3.2.3.1.1.7
This object indicates the applied protocol.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER fr(1), frPlus(2), pCellRelay(3), hdlcSdlc(4), transparentHdlc(5), async(6), asyncReliable(7), activePPP(8), slip(9), pppAgent(10), slipAgent(11), transparent(12), sna(13), ft1Dot2(14)  

prtExPhPlConnectionTyp 1.3.6.1.4.1.164.3.2.3.2.3.1.1.8
This attribute indicates the link connection type. It is required for three reasons: FR/CR Inband management opration (LMI,CLMM...). CIR check. NMS network management. SameNetManaged - indicates network internal line. SameNetMotMana - indicates network internal line, but the remote mux is not managed by the NMS. User - User to Network Interface. OtherNet - Network To Network Interface. PubNet - Access Mux To PubNet Interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER sameNetManaged(1), sameNetNotMana(2), user(3), otherNet(4), pubNet(5), notApplicable(255)  

prtExPhPlClkMode 1.3.6.1.4.1.164.3.2.3.2.3.1.1.9
Clock mode.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER dce(1), extDce(2), dte(3), int(4), lbt(5)  

prtExPhPlDceClkSrc 1.3.6.1.4.1.164.3.2.3.2.3.1.1.10
This attribute indicates the source of the clock when working in dce or ext-dce clock mode. notApplicable(1) - is applied for dte(3) and lbt(5) clock modes. When clock mode is dte, the clock source is always external, therefore this object's value is notApplicable. local(2) and nodalTiming(3) - are valid in dce(1), extDce(2) or int(4) clock modes. The recommended clock source is local(2).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), local(2), nodalTiming(3)  

prtExPhPlCongResponse 1.3.6.1.4.1.164.3.2.3.2.3.1.1.11
This attribute indicates how to handle the congestion indication to/from the mux internal connection side (for example transmit/received becn to/from the network). no - do nothing flowControl - translates the congestion indication between the port and the internal connection port according to the definition of the prtInPh1MlFlowControl parameters. The operation is done on both directions. toFlowControl- translates the backward congestion indication received from the internal connection port (normally the network side) to flow control and do nothing in the other direction.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER no(2), flowControl(3), toFlowControl(4)  

prtExPhPlCongLevel 1.3.6.1.4.1.164.3.2.3.2.3.1.1.12
This attribute indicates the level of delayed data in precents of total available dynamic memory, for which the port will start to operate as congested. The resolution of the parameter is 5 percent.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..70  

prtExPhPlTc 1.3.6.1.4.1.164.3.2.3.2.3.1.1.13
This attribute indicates the Tc parameter which is the time period of the sliding window in which the Bc/Be are tested. The value of this parameter is identical for all the ports of a specific card .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER tc1sec(1), tc2sec(2), tc3sec(3), tc4sec(4), notApplicable(255)  

prtExPhPlFlowControl 1.3.6.1.4.1.164.3.2.3.2.3.1.1.14
This attribute indicates the required flow control betweeen the port and the remote equipment. fecnBecn - is valid only for FR, FR+ and CR protocols. xonXoff,dtrCts - are valid only for Async protocols. speedReduction - is valid only for DLC protocol when the Clock Mode is DCE and the Clock Source is Local.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(2), fecnBecn(3), xonXoff(4), dtrCts(5), speedReduction(6)  

prtExPhPlDcdRts 1.3.6.1.4.1.164.3.2.3.2.3.1.1.15
Protocol may require end to end connect indication over the network. End to end link connection establishment over the FR network will be indicated to the user by using DCD or RTS control signals, depending on the clock mode: DCE or DTE respectively. The options are : - On : DCD(DCE)/RTS(DTE) will be constantly ON no matter if the End to End connection is established or not. - End to End: The DCD(DCE)/RTS(DTE) will be according to the status of the End to End connection.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), on(2), endToEnd(3)  

prtExPhPlDcdRtsControlPath 1.3.6.1.4.1.164.3.2.3.2.3.1.1.16
Protocol may require end to end connect indication over the network. This parameter defines whether to take the user connection status (RTS(DCE)/DCD(DTE)) and forward it to the network side. - on : Transmit active connection to the network regardless the RTS/DCD control lines status. - off: Transmit active connection to the network according to the status of the RTS/DCD pin.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), off(2), on(3)  

prtExPhPlDataBits 1.3.6.1.4.1.164.3.2.3.2.3.1.1.17
This attribute indicates the number of data bits in async frame. It is relevant only for Async protocols.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), dataBits7Bits(2), dataBits8Bits(3)  

prtExPhPlParity 1.3.6.1.4.1.164.3.2.3.2.3.1.1.18
This attribute indicates the parity operation mode in async frame. It is relevant only for Async protocols.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), odd(2), even(3), none(4)  

prtExPhPlStopBits 1.3.6.1.4.1.164.3.2.3.2.3.1.1.19
This attribute indicates the minimum number of stop bits in the tx async frame. It is relevant only for Async protocols.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), sb1Bit(2), sb1dot5Bits(3), sb2Bits(4)  

prtExPhPlLXon 1.3.6.1.4.1.164.3.2.3.2.3.1.1.20
This attribute indicates the character used as X-On to notify receive enable. This parameter is valid only for async protocols. Valid values: 0..255. The value 256 indicates that it's not applicable
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtExPhPlLXoff 1.3.6.1.4.1.164.3.2.3.2.3.1.1.21
This attribute indicates the character used as X-Off to notify receive disable. This parameter is valid only for async protocols. Valid values: 0..255. The value 256 indicates that it's not applicable
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtExPhPlFrMngProt 1.3.6.1.4.1.164.3.2.3.2.3.1.1.22
This object indicates the Frame-Relay management protocol. ansiT1 = ANSI T1.617 Annex D (this is the default value). This parameter is applicable only for FR and FR+ protocols. When prtExPhPlConnectionTyp = sameNetManaged, this object will be RO (internally determined).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), none(2), lmi(3), ansiT1(4), annexA(5)  

prtExPhPlEnqPeriod 1.3.6.1.4.1.164.3.2.3.2.3.1.1.23
This object is the Status Enquiry Period, in seconds. It determines the frequency of the Status Enquiry message as sent by the FR user side. At the FR network side, it determines the timeout for this message reception. Default = 4 seconds. This parameter is applicable only for FR and FR+ protocols AND only when prtExPhPlFrMngProt is NOT (notApplicable or none).
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..30  

prtExPhPlFullRptPeriod 1.3.6.1.4.1.164.3.2.3.2.3.1.1.24
This object is the Full Report Frequency. It determines the number of the Status Enquiry messages sent by the FR user side, before a Full Report Request is sent. The units are : Status Enquiry messages (periods). Valid values: 1 .. 255. 255 = infinite. This parameter is applicable only for FR and FR+ protocols AND only when prtExPhPlFrMngProt is NOT (notApplicable or none).
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..255  

prtExPhPlFrWindowSize 1.3.6.1.4.1.164.3.2.3.2.3.1.1.25
This object is the FR Window Size. It determines the number of samplings in the sliding window that counts the errors. This parameter is applicable only for FR and FR+ protocols AND only when prtExPhPlFrMngProt is NOT (notApplicable or none).
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..10  

prtExPhPlErrorsThreshold 1.3.6.1.4.1.164.3.2.3.2.3.1.1.26
This object is the Max Errors. It determines the number of Status Enquiry Errors that occured within the FR sliding window, before this port is considered DOWN (threshold). This parameter is applicable only for FR and FR+ protocols AND only when prtExPhPlFrMngProt is NOT (notApplicable or none).
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..10  

prtExPhPlPvcCreateMsg 1.3.6.1.4.1.164.3.2.3.2.3.1.1.27
This object is Update Message (if required or not). It determines whether a message of a New PVC Creation is requested or not (yes/no). Default = no. This parameter is applicable only for FR and FR+ protocols AND only when prtExPhPlFrMngProt is NOT (notApplicable or none).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

prtExPhPlCllmMsg 1.3.6.1.4.1.164.3.2.3.2.3.1.1.28
This object is CLLM Message (if required or not). It determines whether to send (or not) a congestion message when the port is Rx congested. Default = no. This parameter is applicable only for FR and FR+ protocols AND only when prtExPhPlFrMngProt is NOT (notApplicable or none).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

prtExPhPlProtDelayLevel 1.3.6.1.4.1.164.3.2.3.2.3.1.1.29
This object is the Segmentation in Bytes. In some cases, the enumerated values will mean other segmentation values than specified: Product: MX-3000 MX-3000 MX-300/MX-30 Protocol: FR+ Transparent FR+ ----------------------------------------------------- level 1 50 Bytes 44 Bytes 50 Bytes level 2 158 Bytes 155 Bytes 158 Bytes level 3 266 Bytes 266 Bytes 266 Bytes level 4 376 Bytes 377 Bytes 376 Bytes level 5 484 Bytes 488 Bytes 484 Bytes Defval=level 1 value This parameter is applicable only for FR+ and transparent protocols.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), s36Byte(2), s150Byte(3), s264Byte(4), s378Byte(5), s492Byte(6)  

prtExPhPlClockEncoding 1.3.6.1.4.1.164.3.2.3.2.3.1.1.30
This object is the Encoding type of the Line. This parameter is applicable only for FR and FR+ protocols. For MAXCESS 3000 & MP2100H: when setting to nrzI (3) the nrzI works as nrzI Mark. For MAXCESS 30/300 when setting to nrzI (3) the nrzI works as nrzI Space.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), nrz(2), nrzI(3), fm0(4), manchester(5), diffManchester(6), nrzISpace(7), nrzIMark(8)  

prtExPhPlMinSeparators 1.3.6.1.4.1.164.3.2.3.2.3.1.1.31
Minimum number of bytes separating between two adjacent frames (HDLC item). 0 = notApplicable
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..16  

prtExPhPlCcittCrc 1.3.6.1.4.1.164.3.2.3.2.3.1.1.32
This object indicates how many Bits are used for CRC (HDLC item).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), crc16(2), crc32(3)  

prtExPhPlFrameSeparator 1.3.6.1.4.1.164.3.2.3.2.3.1.1.33
This object indicates what should be transferred on the line when there are no frames to pass (HDLC item). idles: mean that FF will pass on the line flags: mean that 7E will pass on the line.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), idles(2), flags(3)  

prtExPhPlIdleCode 1.3.6.1.4.1.164.3.2.3.2.3.1.1.34
Determines the code for transmission when there are no frames to transmit on the line. The value should be 0 to FFH.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtExPhPlJitter 1.3.6.1.4.1.164.3.2.3.2.3.1.1.35
Maximum variant delay of the FR network, in msec.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..1000  

prtExPhPlDlciTable 1.3.6.1.4.1.164.3.2.3.2.3.2
The write operation into the Table Objects is valid only at the TmpCnfg entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExPhPlDlciEntry

prtExPhPlDlciEntry 1.3.6.1.4.1.164.3.2.3.2.3.2.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtExPhPlDlciEntry  

prtExPhPlDlciCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.3.2.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

prtExPhPlDlciSltIdx 1.3.6.1.4.1.164.3.2.3.2.3.2.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtExPhPlDlciPrtIdx 1.3.6.1.4.1.164.3.2.3.2.3.2.1.3
This attribute indicates a unique internal port number. PH.1/E1 and PH.1/T1 cards have three internal ports. Stand-alone units may have six such ports.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6)  

prtExPhPlDlciIdx 1.3.6.1.4.1.164.3.2.3.2.3.2.1.4
This attribute indicates a unique index for each possible used dlci(16..991). When the protocol is not Multiplexing protocol, its type is 'user' and the only valid index is 1.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..991  

prtExPhPlDlciValid 1.3.6.1.4.1.164.3.2.3.2.3.2.1.5
This attribute indicates whether the attributes in this entry are valid or not. The user can add/delete pvc (dlci to dlci connection) by modifing this object
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtExPhPlDlciIConSlt 1.3.6.1.4.1.164.3.2.3.2.3.2.1.6
This attribute indicates a unique slot position In the Mux (Agent) where the dlci is routed to. cl - will represent any of the CL slots. This value can be selected for multiple DLCIs of the product. In the ?004 Unit the entries io6(10)..io16) are not valid
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noConnect(2), cl(3), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtExPhPlDlciIConPrt 1.3.6.1.4.1.164.3.2.3.2.3.2.1.7
This attribute indicates a unique port id which the dlci is routed to. clNMS - will be used for NMS SNMP messages. It can be any port of the CL card. This value will be selectable only if prtExPhPlDlciIConSlt='cl' or 'notApplicable'.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6), exPrt7(7), exPrt8(8), exPrt9(9), exPrt10(10), clNMS(99), noConnect(100), inPrt1(101), inPrt2(102), inPrt3(103), inPrt4(104), inPrt5(105), inPrt6(106), inPrt7(107), inPrt8(108), inPrt9(109), inPrt10(110)  

prtExPhPlDlciIConDlci 1.3.6.1.4.1.164.3.2.3.2.3.2.1.8
This attribute indicates a unique internal connection dlci number, the dlci is routed to.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..991  

prtExPhPlDlciTxBc 1.3.6.1.4.1.164.3.2.3.2.3.2.1.9
This attribute indicates a unique Tx committed bandwidth on the user transmit line (or at the port receive line).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER full(1), zero(2), txBc9600bps(3), txBc14400bps(4), txBc19200bps(5), txBc28800bps(6), txBc32000bps(7), txBc38400bps(8), txBc48000bps(9), txBc56000bps(10), txBc57600bps(11), txBc64Kbps(12), txBc128Kbps(13), txBc192Kbps(14), txBc256Kbps(15), txBc320Kbps(16), txBc384Kbps(17), txBc448Kbps(18), txBc512Kbps(19), txBc768Kbps(20), txBc1024Kbps(21), txBc16000bps(25), txBc112Kbps(26)  

prtExPhPlDlciTxBe 1.3.6.1.4.1.164.3.2.3.2.3.2.1.10
This attribute indicates a unique Tx excess bandwidth on the user transmit line (or at the port receive line).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER full(1), zero(2), txBe9600bps(3), txBe14400bps(4), txBe19200bps(5), txBe28800bps(6), txBe32000bps(7), txBe38400bps(8), txBe48000bps(9), txBe56000bps(10), txBe57600bps(11), txBe64Kbps(12), txBe128Kbps(13), txBe192Kbps(14), txBe256Kbps(15), txBe320Kbps(16), txBe384Kbps(17), txBe448Kbps(18), txBe512Kbps(19), txBe768Kbps(20), txBe1024Kbps(21), txBc16000bps(25), txBc112Kbps(26)  

prtExPhPlDlciRxBc 1.3.6.1.4.1.164.3.2.3.2.3.2.1.11
This attribute indicates a unique Rx committed bandwidth on the user receive line (or at the port transmit line).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER full(1), zero(2), rxBc9600bps(3), rxBc14400bps(4), rxBc19200bps(5), rxBc28800bps(6), rxBc32000bps(7), rxBc38400bps(8), rxBc48000bps(9), rxBc56000bps(10), rxBc57600bps(11), rxBc64Kbps(12), rxBc128Kbps(13), rxBc192Kbps(14), rxBc256Kbps(15), rxBc320Kbps(16), rxBc384Kbps(17), rxBc448Kbps(18), rxBc512Kbps(19), rxBc768Kbps(20), rxBc1024Kbps(21), rxBc16000bps(25), rxBc112Kbps(26)  

prtExPhPlDlciRxBe 1.3.6.1.4.1.164.3.2.3.2.3.2.1.12
This attribute indicates a unique Rx excess bandwidth on the user receive line (or at the port transmit line).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER full(1), zero(2), rxBe9600bps(3), rxBe14400bps(4), rxBe19200bps(5), rxBe28800bps(6), rxBe32000bps(7), rxBe38400bps(8), rxBe48000bps(9), rxBe56000bps(10), rxBe57600bps(11), rxBe64Kbps(12), rxBe128Kbps(13), rxBe192Kbps(14), rxBe256Kbps(15), rxBe320Kbps(16), rxBe384Kbps(17), rxBe448Kbps(18), rxBe512Kbps(19), rxBe768Kbps(20), rxBe1024Kbps(21), rxBc16000bps(25), rxBc112Kbps(26)  

prtExPhPlDlciPriority 1.3.6.1.4.1.164.3.2.3.2.3.2.1.13
This attribute indicates a unique priority of the pcv. 1 is the lowest priority and 8 is the highest priority.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..8  

prtExPhPlDlciStatus 1.3.6.1.4.1.164.3.2.3.2.3.2.1.14
This attribute indicates the status of the pvc. The status is disconnected(1) when one of the sides is programmed as not connected
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER disconnected(1), connected(2)  

prtExPhPlModemTable 1.3.6.1.4.1.164.3.2.3.2.3.3
External Modem Parameters. The write operation into the Table Objects is valid only for the TmpCnfg entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExPhPlModemEntry

prtExPhPlModemEntry 1.3.6.1.4.1.164.3.2.3.2.3.3.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtExPhPlModemEntry  

prtExPhPlModemCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.3.3.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

prtExPhPlModemSltIdx 1.3.6.1.4.1.164.3.2.3.2.3.3.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtExPhPlModemPrtIdx 1.3.6.1.4.1.164.3.2.3.2.3.3.1.3
This attribute indicates a unique port number. In case of PH.1 card, only exPrt(1) is valid.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6)  

prtExPhPlModemStatus 1.3.6.1.4.1.164.3.2.3.2.3.3.1.4
This object indicates whether a Dial Up Modem is enabled on this port. Default: disable For Vmux devices this object shows whether there is Modem Relay support.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(2), enable(3), relay(4)  

prtExPhPlModemActivate 1.3.6.1.4.1.164.3.2.3.2.3.3.1.5
This object indicates whether the Dial Up Modem is activated when the first frame is received or it is always activated. Default: onFirstFrame
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER onFirstFrame(2), always(3), notApplicable(255)  

prtExPhPlModemMaxIdleTime 1.3.6.1.4.1.164.3.2.3.2.3.3.1.6
Max Time allowed in Seconds without any traffic before the line is disconnected. Legal Values are: 1 sec, 2 sec .. 5 sec, 10 sec, 20 sec.. 1 min, 2 min .. 10 min, 15 min, 20 min, 25 min, 30 min. 65535 sec. means that this parameter is not applicable. Default: 1 sec.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtExPhPlModemTimeBtwnCalls 1.3.6.1.4.1.164.3.2.3.2.3.3.1.7
Minimum Time in Seconds which is required after a call was disconnected. In this time no other call will be initiated from this Modem port even if there were frames transmitted to this port. This time is required for some Modems which have initializations that take a few seconds. Legal Values are: 0 sec. - 30 sec., 1-5 min. 65535 sec. means that this parameter is not applicable. Default: 0 sec
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtExPhPlModemCallDelay 1.3.6.1.4.1.164.3.2.3.2.3.3.1.8
Time in Seconds that the device will wait before dialing to the remote device. This feature is mostly used when there is a backup modem to the main link and the main link is down. In this case it is important to prevent the 2 devices from dialing through the backup modems to each other at the same time. It is advised to configure one side with a small call delay and the other side with a large call delay. Legal Values are: 0 - 30, 60, 120, 180, 240, 300, 600, 900, 1200, 1500, 1800 . 65535 sec. means that this parameter is not applicable. Default: 0 sec
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtExLs2CnfgTable 1.3.6.1.4.1.164.3.2.3.2.4.1
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExLs2CnfgEntry

prtExLs2CnfgEntry 1.3.6.1.4.1.164.3.2.3.2.4.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtExLs2CnfgEntry  

prtExLs2CnfgIdx 1.3.6.1.4.1.164.3.2.3.2.4.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

prtExLs2SltIdx 1.3.6.1.4.1.164.3.2.3.2.4.1.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExLs2PrtIdx 1.3.6.1.4.1.164.3.2.3.2.4.1.1.3
This attribute indicates a unique port index. For the Ls2/X.58 exPrt(7)..exPrt(10) are not valid.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6), exPrt7(7), exPrt8(8), exPrt9(9), exPrt10(10)  

prtExLs2Connect 1.3.6.1.4.1.164.3.2.3.2.4.1.1.4
This attribute indicates whether the port should be considered in any of the mux algorithms.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtExLs2Rate 1.3.6.1.4.1.164.3.2.3.2.4.1.1.5
Port rates.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER r2400bps(2), r4800bps(3), r9600bps(4), r19200bps(5)  

prtExLs2ClkMode 1.3.6.1.4.1.164.3.2.3.2.4.1.1.6
This attribute indicates a unique port operation clock mode.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER dce(1), ext-dce(2), dte(3)  

prtExLs2Cts 1.3.6.1.4.1.164.3.2.3.2.4.1.1.7
CTS.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER on(2), rts-min(3), rts-max(4)  

prtExLs2Dcd 1.3.6.1.4.1.164.3.2.3.2.4.1.1.8
DCD.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER on(2), card-sync(3)  

prtExLs2EnvIdx 1.3.6.1.4.1.164.3.2.3.2.4.1.1.9
Envelope Index. When prtInLs2EnvAssign=auto, the value is 0 (not applicable).
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..24  

prtInLs2CnfgTable 1.3.6.1.4.1.164.3.2.3.2.4.2
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtInLs2CnfgEntry

prtInLs2CnfgEntry 1.3.6.1.4.1.164.3.2.3.2.4.2.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtInLs2CnfgEntry  

prtInLs2CnfgIdx 1.3.6.1.4.1.164.3.2.3.2.4.2.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

prtInLs2SltIdx 1.3.6.1.4.1.164.3.2.3.2.4.2.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtInLs2PrtIdx 1.3.6.1.4.1.164.3.2.3.2.4.2.1.3
This attribute indicates a unique internal port index.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER inPrt1(101), inPrt2(102)  

prtInLs2Connect 1.3.6.1.4.1.164.3.2.3.2.4.2.1.4
This attribute indicates whether the port should be considered in any of the mux algorithms. It also affects all the module considerations because the module has only one Internal interface which is the composite channel.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtInLs2Group 1.3.6.1.4.1.164.3.2.3.2.4.2.1.5
This attribute indicates the group number of the port. LS-2 internal ports with the same group number share the same Time slot of the main link
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..12  

prtInLs2Member 1.3.6.1.4.1.164.3.2.3.2.4.2.1.6
This attribute indicates the group member id of the port. This parameter is for the automatic envelope assignment algorithm.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..4  

prtInLs2LinkTo 1.3.6.1.4.1.164.3.2.3.2.4.2.1.7
It indicates the slot of the main link card to which the LS2 card is mapped. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort.
Status: deprecated Access: read-write
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtInLs2EnvAssign 1.3.6.1.4.1.164.3.2.3.2.4.2.1.8
Envelope assignment type.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER auto(2), manual(3)  

prtVc2CnfgTable 1.3.6.1.4.1.164.3.2.3.2.5
- For products supporting more than one configuration, the write operation into the Table is valid only to the TmpCnfg entry. - For products that do not support configurations, the write operation into the Table will be to prtVc2CnfgIdx=1.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtVc2CnfgEntry

prtVc2CnfgEntry 1.3.6.1.4.1.164.3.2.3.2.5.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtVc2CnfgEntry  

prtVc2CnfgIdx 1.3.6.1.4.1.164.3.2.3.2.5.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

prtVc2SltIdx 1.3.6.1.4.1.164.3.2.3.2.5.1.2
This attribute indicates a unique slot position where the card is inserted. For Stand Alone products like WR: notApplicable (255)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtVc2PrtIdx 1.3.6.1.4.1.164.3.2.3.2.5.1.3
A unique identifier of the port, within the card. For MP-2100/2200 card ports, Web Ranger and FCD-IP Voice ports the values will be: exPrt1 (1) exPrt2 (2) exPrt3 (3) exPrt4 (4) exPrt5 (5) exPrt6 (6) exPrt7 (7) exPrt8 (8) exPrt9 (9) exPrt10 (10) exPrt11 (11) exPrt12 (12) exPrt13 (13) exPrt14 (14) exPrt15 (15) exPrt16 (16) For LA-240: The index for fixed voice ports will be - exPrt6 (6) exPrt7 (7) exPrt8 (8) exPrt9 (9) The index for voice card ports will be - Slot number * 100 + ch (for IO-1: 101..104, for IO-2: 201..204). For other products' index see their specification.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtExVc2Connect 1.3.6.1.4.1.164.3.2.3.2.5.1.4
This attribute indicates whether the port should be considered in any of the mux algorithms.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3), v51(4), v52(5)  

prtExVc2TransGain 1.3.6.1.4.1.164.3.2.3.2.5.1.5
Transmit gain in dBm. For ports of MP-104/204, MP-2100/2200 VC-6A, VC-6AG, VC-8 VC-4/Omni and VC-16 cards, the units will be 0.1dBm because valid values can be in 0.5dBm steps.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtExVc2ReceiveGain 1.3.6.1.4.1.164.3.2.3.2.5.1.6
Receive gain in dBm. For ports of MP-104/204, MP-2100/2200 VC-6A, VC-6AG, VC-8 VC-4/Omni and VC-16 cards, the units will be 0.1dBm because valid values can be in 0.5dBm steps.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtExVc2Wire 1.3.6.1.4.1.164.3.2.3.2.5.1.7
For some cards, this object is equal for all the ports in the specific card because of HW limitations. For FXO & FXS this parameter is not applicable.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER w2wire(1), w4wire(2), notApplicable(255)  

prtExVc2CodingLaw 1.3.6.1.4.1.164.3.2.3.2.5.1.8
This attribute indicates the Method/Law for decoding/encoding the voice information. aLaw(1) is the standard Law for E1 links. uLaw(2) is the standard Law for T1 links. This object is equal for all the ports in the specific module because of HW limitations
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER aLAW(1), uLAW(2)  

prtExVc2Sig 1.3.6.1.4.1.164.3.2.3.2.5.1.9
This attribute indicates the method for decoding/encoding the signaling information(on/off hook). noSignaling (1) - not using signaling (only voice). robbedBitMultiFrame(2) - is the standard method for T1 links and proprietary method for E1 links. chAssociatedE1 (3) - is valid only for E1 G.732S links. robbedBitFrame (4) - is proprietary method implimenting 7 bit for the voice and 1 bit dedicated for signaling. For some cards, this object is equal for all the ports in the specific module because of HW limitations.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noSignaling(1), robbedBitMultiFrame(2), chAssociatedE1(3), robbedBitFrame(4)  

prtExVc2Oos 1.3.6.1.4.1.164.3.2.3.2.5.1.10
This object is equal for all the ports in the specific card because of HW limitations
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER forcedIdle(1), forcedBusy(2), busyIdle(3), idleBusy(4), notApplicable(5)  

prtExVc2LinkTo 1.3.6.1.4.1.164.3.2.3.2.5.1.11
This attribute indicates the slot of the ML card to which the VC card is mapped. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort.
Status: deprecated Access: read-write
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtExVc2OperMode 1.3.6.1.4.1.164.3.2.3.2.5.1.12
This object indicates the operation mode of the port. normal = bi-directional (Tx/Rx) unidirectRx = unidirectional Rx. broadcast = Tx upon request.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER normal(2), unidirectRx(3), broadcast(4)  

prtExVc2SigProfile 1.3.6.1.4.1.164.3.2.3.2.5.1.13
This object indicates the Signaling Profile of the port. notApplicable - for VC-2 family and when prtExVc2Sig=noSignaling(1) p1 = profile 1 p2 = profile 2 p3 = profile 3 p4 = profile 4
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), manual(2), p1(3), p2(4), p3Fxo3S3(5), reversePolarity(6), meteringPulse(7), p4(8)  

prtExVc2CallEnable 1.3.6.1.4.1.164.3.2.3.2.5.1.14
This object indicates the Enabled Call direction. notApplicable - for all cards except VC-2/R2. both - incoming + outgoing.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), incoming(2), outgoing(3), both(4)  

prtExVc2R2Delay 1.3.6.1.4.1.164.3.2.3.2.5.1.15
This object indicates the R2 Delay. notApplicable - for all cards except VC-2/R2.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), terrestrial(2), satellite(3)  

prtExVc2CasStd 1.3.6.1.4.1.164.3.2.3.2.5.1.16
This object indicates the CAS (Channel Associated Signaling) Standard. notApplicable - for all cards except VC-2/R2.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), r2Q422(2), specialA(3), specialB(4), specialC(5), specialD(6), specialE(7), specialF(8), specialG(9)  

prtExVc2EchoCanceler 1.3.6.1.4.1.164.3.2.3.2.5.1.17
Echo canceler activation. notApplicable - for VC-2 and VC-6 cards.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), off(2), on(3)  

prtExVc2IfType 1.3.6.1.4.1.164.3.2.3.2.5.1.18
Interface Type.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), w2Em(2), w4Em(3), fxo(4), fxs(5)  

prtExVc2Encoding 1.3.6.1.4.1.164.3.2.3.2.5.1.19
Voice Encoding Mode. linear - is relevant only for the ports of VC-16A card.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), pcm(2), adpcm(3), linear(4)  

prtExVc2TxBitCode 1.3.6.1.4.1.164.3.2.3.2.5.1.20
- - - For MP & FCD - - - This object represents 4 parameters, by 2 Octets : Tx D Bit Code-MSB nibble, Tx C Bit Code- nibble, Tx B Bit Code- nibble, Tx A Bit Code-LSB nibble. Each nibble: 0 hex = 0000 = Not Applicable 1 hex = 0001 = M lead 2 hex = 0010 = M lead inverse 3 hex = 0011 = Reverse Polarity 4 hex = 0100 = Metering Pulse 5 hex = 0101 = Forced 1 6 hex = 0110 = Forced 0 7-F hex - not used (invalid values) This object will be RO if prtExVc2SigProfile is NOT manual. - - - For WR II - - - This object represents the following 4 parameters by 2 Octets: 1. On/Off hook signaling transmission mode from the FXS towards the T1/E1 (MSB nibble 1). 2. Default signaling bits that are not in use (nibble 2). 3. Ring Detection signaling transmission mode from the FXO towards the T1/E1(nibble 3). 4. M (Mouth) Signaling transmission mode from the E&M towards the T1/E1(LSB nibble 4). Each nibble: --------------------------------------------------------------------------------------- Value On/Off Hook Default sig. Ring Detect. M (Mouth) --------------------------------------------------------------------------------------- 0 hex = 0000 Not Applicable Not Applicable. Not Applicable Not Applicable 1 hex = 0001 Tx A bit Values 1-3 are Tx A bit Tx A bit 2 hex = 0010 Tx A bit inverse for On/Off Hook Tx A bit inv. Tx A bit inv. 3 hex = 0011 Tx B bit A,B,A Inv,B Inv. Tx B bit Tx B bit 4 hex = 0100 Tx B bit inverse Values 4-7 are Tx B bit inv. Tx B bit inv. 5 hex = 0101 not Used-invalid for On/Off Hook not Used-invalid not Used-invalid 6 hex = 0110 not Used-invalid A, A Inverse. not Used-invalid not Used-invalid 7 hex = 0111 not Used-invalid not Used-invalid not Used-invalid 8 hex = 1000 not Used-invalid Values 8-11 are not Used-invalid not Used-invalid 9 hex = 1001 not Used-invalid for On/Off Hook not Used-invalid not Used-invalid A hex = 1010 not used-invalid B, B Inverse. not Used-invalid not Used-invalid B hex = 1011 not used-invalid The Bits order: not Used-invalid not Used-invalid C-F hex not used-invalid ABCD not Used-invalid not Used-invalid Default value: 11 11
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

prtExVc2RxBitOutput 1.3.6.1.4.1.164.3.2.3.2.5.1.21
- - - For MP (VC-Q card only) & FCD - - - This object represents 3 parameters by 2 Octets: Spare -MSB nibble, always=0 hex E Lead Output - nibble, Reverse Polarity Output- nibble, Metering Pulse Output -LSB nibble. Each nibble: 0 hex = 0000 = Not Applicable 1 hex = 0001 = Rx A bit 2 hex = 0010 = Rx A bit inverse 3 hex = 0011 = Rx B bit 4 hex = 0100 = Rx B bit inverse 5 hex = 0101 = Rx C bit 6 hex = 0110 = Rx C bit inverse 7 hex = 0111 = Rx D bit 8 hex = 1000 = Rx D bit inverse 9 hex = 1001 = none A-F hex - not used (invalid values) This object will be RO if prtExVc2SigProfile is NOT manual. - - - For MP (VC-8, VC-16, VC-16A cards) - - - This object represents 4 parameters, by 2 Octets : Tx D Bit Code-MSB nibble, Tx C Bit Code- nibble, Tx B Bit Code- nibble, Tx A Bit Code-LSB nibble. Each nibble: 0 hex = 0000 = Not Applicable 1 hex = 0001 = not used (invalid value) 2 hex = 0010 = not used (invalid value) 3 hex = 0011 = not used (invalid value) 4 hex = 0100 = not used (invalid value) 5 hex = 0101 = Forced 1 6 hex = 0110 = Forced 0 7-F hex - not used (invalid values) This object will be RO. - - - For WR II - - - This object represents the following 2 parameters in 1 Octet: 1. On/Off hook signaling receive mode from the T1/E1 into the FXS/FXO (MSB nibble 1). 2. E (Ear) Signaling receive mode from the T1/E1 into the E&M (LSB nibble 2). Each nibble: --------------------------------------------------------------------------------------- Value On/Off Hook E (Ear) --------------------------------------------------------------------------------------- 0 hex = 0000 Not Applicable Not Applicable 1 hex = 0001 Rx A bit Rx A bit 2 hex = 0010 Rx A bit inverse Rx A bit inverse 3 hex = 0011 Rx B bit Rx B bit 4 hex = 0100 Rx B bit inverse Rx B bit inverse 5-F hex not used-invalid not Used-invalid Default value: 11
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

prtExVc2MeterRate 1.3.6.1.4.1.164.3.2.3.2.5.1.22
This entry is applicable only for VC-6A/FXO, VC-6A/FXS, VC-8/FXO, VC-8/FXS, VC-16/FXO and VC-16/FXS. Meter Rate means rate of Call Meter in Public Phones, in KHz units. For some cards, the value must be the same for all card's ports.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), r16Khz(2), r12Khz(3), disabled(4)  

prtExVc2IfSignaling 1.3.6.1.4.1.164.3.2.3.2.5.1.23
This entry is applicable only for VC-6A, VC-6AG, VC-8/FXO, VC-8/FXS, VC-16/FXO and VC-16/FXS cards. Interface Analog Signaling. Must be the same for all card's ports. loopStart - for the usual trunk/phone types. groundStart - for trunks that need Ground signaling . winkStart - for trunks that need Reverse Polarity.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), loopStart(2), groundStart(3), winkStart(4)  

prtExVc2SeizeAck 1.3.6.1.4.1.164.3.2.3.2.5.1.24
This parameter shows whether the device will acknowledge a seize signal (On/Off Hook). When the value is set to yes(3) & the device receives an on/off hook signal it will transmit back an on/off hook signal. When the value is set to no(2) & the device receives an on/off hook signal it will NOT transmit back an on/off hook signal. Default value for WR FXO: no(2).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

prtExVc2EandMType 1.3.6.1.4.1.164.3.2.3.2.5.1.25
This is the signaling type on the E&M analog side. The analog signaling includes voltage, no. of pins and other parameters.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), type1(2), type2(3), type3(4), type5(5)  

prtExVc2RemType 1.3.6.1.4.1.164.3.2.3.2.5.1.26
Remote Type. Applicable for VC-6A/4LB card & for IPMUX-1E Far End Type - E1,T1(T1-ESF) or T1-D4 .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), lb(2), pbx(3), e1(4), t1(5), t1D4(6)  

prtExVc2ConvTime 1.3.6.1.4.1.164.3.2.3.2.5.1.27
Conversation Time in minutes. Applicable for VC-6A/4LB card.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), m2(2), m3(3), m5(4), unlimited(5)  

prtExVc2SigFeedback 1.3.6.1.4.1.164.3.2.3.2.5.1.28
Signaling Feedback. Applicable for VC-8/FXO and VC-16/FXO cards.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

prtExVc2EchoCancelerModule 1.3.6.1.4.1.164.3.2.3.2.5.1.29
This parameter indicates whether Echo canceler module exists for this port.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), notExist(2), exist(3)  

prtExVc2ReversePolarity 1.3.6.1.4.1.164.3.2.3.2.5.1.30
This object Enables/Disables Reverse Polarity for this port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

prtExVc2RingerFrequency 1.3.6.1.4.1.164.3.2.3.2.5.1.31
This object selects the Ringer Frequency (Hz) for this port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), f20Hz(2), f25Hz(3), f50Hz(4)  

prtExVc2SigService 1.3.6.1.4.1.164.3.2.3.2.5.1.32
Signaling Service. advanced - is relevant only for ports of VC-8, VC-16 FXS cards. It is used for Signaling Services of V5.1 or R2.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), normal(2), advanced(3)  

prtExVc2CallerIdEnable 1.3.6.1.4.1.164.3.2.3.2.5.1.33
This object Enables/Disables Receiving the Caller Id number from the remote side, for this port/channel.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

prtExVc2CompressMethod 1.3.6.1.4.1.164.3.2.3.2.5.1.34
This object is applicable only when prtExVc2Encoding=adpcm. It defines which method is used for Compression. g726 - for 4 bits (the standard method). g726 - for 3 bits. It is especially needed for T1 applications with signaling.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), g726(2), g727(3)  

prtExVc2ObMode 1.3.6.1.4.1.164.3.2.3.2.5.1.35
This object defines the Net operation mode of the Omni-Bus card's port. pointToPoint - only 2 end-point ports talk; like any other voice card omniBus - many talk and listen. Like conference call. All can listen to all. pointToMultiPointSrc - There is one Master who can be heard by all. All can talk, but only the Master can hear all. Others can hear only the Master. This port is of the Master (Src). pointToMultiPointDst - There is one Master who can be heard by all. All can talk, but only the Master can hear all. Others can hear only the Master. This port is of a Destination (NOT Master).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER pointToPoint(1), omniBus(2), pointToMultiPointSrc(3), pointToMultiPointDst(4)  

prtExVc2VAD 1.3.6.1.4.1.164.3.2.3.2.5.1.36
This object defines whether Voice Activation Detector (VAD) will be On or Off. off - will be usually selected when a Modem is connected to the port; not a phone. notApplicable - when prtExVc2DspMode=pointToPoint.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), off(2), on(3)  

prtExVc2NoiseLevelForVAD 1.3.6.1.4.1.164.3.2.3.2.5.1.37
This object defines the Level of Noise on the line, the Voice Activation Detector (VAD) will have to deal with. notApplicable - when prtExVc2VAD=off.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), low(2), medium(3), high(4)  

prtExVc2WesternSigMode 1.3.6.1.4.1.164.3.2.3.2.5.1.38
This object defines the Western Signaling Mode. detector - detects signal and passes it as is. generator - generates the signal. notApplicable - when Western HW is not installed.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), detector(2), generator(3)  

prtExVc2BusProtectionPoint 1.3.6.1.4.1.164.3.2.3.2.5.1.39
This object defines if the port is Bus Protection Point or not. notApplicable - when prtExVc2DspMode=pointToPoint. When we have a chain of devices where the edge devices ports are the Bus Protection Point, user must configure one of these ports as 'first' and the other as 'last'. It does not matter which one, it just matters that they will be different.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), first(3), last(4)  

prtExVc2ImpedanceStandard 1.3.6.1.4.1.164.3.2.3.2.5.1.40
This object defines the Standard used for Impedance. -G.712 - 600 Ohm - used in USA and other countries. -Q552/ETSI - used in some countries in Europe -Q522/Italy - used in Italy.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER g712(1), q552ETSI(2), q522Italy(3)  

prtHsfCnfgTable 1.3.6.1.4.1.164.3.2.3.2.6
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtHsfCnfgEntry

prtHsfCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.6.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtHsfCnfgEntry  

prtHsfCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.6.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relate to the TmpCnfg.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

prtHsfSltIdx 1.3.6.1.4.1.164.3.2.3.2.6.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtHsfPrtIdx 1.3.6.1.4.1.164.3.2.3.2.6.1.3
This attribute indicates a unique external port index. Hs2 has only two ports (exPrt1,exPrt2). Hs3 has three ports (exPrt1,exPrt2,exPrt3). Hsq and hsqN has four ports. Hs6 has six external ports. Hs12 has twelve external ports. inPrt1, inPrt2 - are relevant for VID card.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6), exPrt7(7), exPrt8(8), exPrt9(9), exPrt10(10), exPrt11(11), exPrt12(12), inPrt1(101), inPrt2(102)  

prtExHsfConnect 1.3.6.1.4.1.164.3.2.3.2.6.1.4
This attribute indicates whether the port should be considered in any of the mux algorithms.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtExHsfRate 1.3.6.1.4.1.164.3.2.3.2.6.1.5
This attribute indicates the port speed.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER r1x56eq56Kbps(1), r1x64eq64Kbps(2), r2x56eq112Kbps(3), r2x64eq128Kbps(4), r3x56eq168Kbps(5), r3x64eq192Kbps(6), r4x56eq224Kbps(7), r4x64eq256Kbps(8), r5x56eq280Kbps(9), r5x64eq320Kbps(10), r6x56eq336Kbps(11), r6x64eq384Kbps(12), r7x56eq392Kbps(13), r7x64eq448Kbps(14), r8x56eq448Kbps(15), r8x64eq512Kbps(16), r9x56eq504Kbps(17), r9x64eq576Kbps(18), r10x56eq560Kbps(19), r10x64eq640Kbps(20), r11x56eq616Kbps(21), r11x64eq704Kbps(22), r12x56eq672Kbps(23), r12x64eq768Kbps(24), r13x56eq728Kbps(25), r13x64eq832Kbps(26), r14x56eq784Kbps(27), r14x64eq896Kbps(28), r15x56eq840Kbps(29), r15x64eq960Kbps(30), r16x56eq896Kbps(31), r16x64eq1024Kbps(32), r17x56eq952Kbps(33), r17x64eq1088Kbps(34), r18x56eq1008Kbps(35), r18x64eq1152Kbps(36), r19x56eq1064Kbps(37), r19x64eq1216Kbps(38), r20x56eq1120Kbps(39), r20x64eq1280Kbps(40), r21x56eq1176Kbps(41), r21x64eq1344Kbps(42), r22x56eq1232Kbps(43), r22x64eq1408Kbps(44), r23x56eq1288Kbps(45), r23x64eq1472Kbps(46), r24x56eq1344Kbps(47), r24x64eq1536Kbps(48), r25x56eq1400Kbps(49), r25x64eq1600Kbps(50), r26x56eq1456Kbps(51), r26x64eq1664Kbps(52), r27x56eq1512Kbps(53), r27x64eq1728Kbps(54), r28x56eq1568Kbps(55), r28x64eq1792Kbps(56), r29x56eq1624Kbps(57), r29x64eq1856Kbps(58), r30x56eq1680Kbps(59), r30x64eq1920Kbps(60), r31x56eq1736Kbps(61), r31x64eq1984Kbps(62), r32Kbps(63)  

prtExHsfClkMode 1.3.6.1.4.1.164.3.2.3.2.6.1.6
This attribute indicates a unique port operation clock mode.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER dce(1), ext-dce(2), dte(3), none(4)  

prtExHsfCts 1.3.6.1.4.1.164.3.2.3.2.6.1.7
This attribute indicates a unique CTS control line operation mode.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), on(2), rts(3)  

prtExHsfFifoSize 1.3.6.1.4.1.164.3.2.3.2.6.1.8
Size in bits.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER auto(2), s16bits(3), s30bits(4), s52bits(5), s72bits(6)  

prtExHsfLinkTo 1.3.6.1.4.1.164.3.2.3.2.6.1.9
This attribute indicates a slot of Main Link module, that the port is linked to. This object is the same for all the ports in the specific card because of HW limitations. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort.
Status: deprecated Access: read-write
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExHsfOperMode 1.3.6.1.4.1.164.3.2.3.2.6.1.10
This object indicates the operation mode of the port. normal = bi-directional (Tx/Rx) unidirectRx = unidirectional Rx. broadcast = Tx upon request. bidirBcastRing = Bidirectional Broadcast Ring. When this value is selected, AND RTS=On, the port opens its transmission channel.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER normal(2), unidirectRx(3), broadcast(4), bidirBcastRing(5)  

prtExHsfInbandLoopback 1.3.6.1.4.1.164.3.2.3.2.6.1.11
This object indicates if Inband Loopback from the Network should be enabled or disabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), ft1Enabled(3)  

prtExHsfClkPolarity 1.3.6.1.4.1.164.3.2.3.2.6.1.12
This object indicates the clock polarity. For FCD-M this object will be applicable only for the fixed HS port (the fixed port on the device).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), normal(2), invert(3)  

prtExHsfControlSignal 1.3.6.1.4.1.164.3.2.3.2.6.1.13
This object indicates the Control Signal according to G.797 ITU-T standard. For FCD-M this object will be applicable for the fixed HS port (the fixed port on the device) and HS-Q/N channels. Local and End to End are applicable only when channel Interface type is RS-530, else it will be Not Applicable.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), local(2), endToEnd(3)  

prtExHsfBcastRingSrcPort 1.3.6.1.4.1.164.3.2.3.2.6.1.14
This object is applicable only when prtExHsfOperMode= bidirBcastRing. In this case, the values mean: - none - this port will be connected to ML in TSA as usual. - exPrt1.. exPrtX ; X=maximum ports of the card in focus : it means that the same TS that is assigned in TSA to this port is actually connected also to this port, for Broadcast Ring mode. Therefore, this port should NOT be connected to ML in TSA.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6), exPrt7(7), exPrt8(8), exPrt9(9), exPrt10(10), exPrt11(11), exPrt12(12), none(100), notApplicable(255)  

prtExHs4CnfgTable 1.3.6.1.4.1.164.3.2.3.2.7.1
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExHs4CnfgEntry

prtExHs4CnfgEntry 1.3.6.1.4.1.164.3.2.3.2.7.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtExHs4CnfgEntry  

prtExHs4CnfgIdx 1.3.6.1.4.1.164.3.2.3.2.7.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

prtExHs4SltIdx 1.3.6.1.4.1.164.3.2.3.2.7.1.1.2
This attribute indicates a unique slot position where the card is inserted.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExHs4PrtIdx 1.3.6.1.4.1.164.3.2.3.2.7.1.1.3
A unique identifier of the port, within the card.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER exPrt1(1)  

prtExHs4Connect 1.3.6.1.4.1.164.3.2.3.2.7.1.1.4
This attribute indicates whether the port should be considered in any of the mux algorithm. It also affects all the module considerations because the card has only one external (physical) interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtExHs4LineType 1.3.6.1.4.1.164.3.2.3.2.7.1.1.5
This attribute is the line type parameter for T1/E1 interface. The user should select only the parameters relevant to the specific card: T1 line code parameters for the HS-4/1 and E1 line code parameters for the HS-4/2. This parameter has the same values as dsx1LineType in T1/E1 MIB (RFC-1406). The parameters in dsx1LineType are: other (1) dsx1ESF (2) dsx1D4 (3) dsx1E1 (4) dsx1E1-CRC (5) dsx1E1-MF (6) dsx1E1-MF-CRC (7)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER esfT1(2), sfT1(3), g732nE1(4), g732nE1CRC(5), g732sE1(6), g732sE1CRC(7)  

prtExHs4LineCode 1.3.6.1.4.1.164.3.2.3.2.7.1.1.6
This attribute is the line code parameter used for T1/E1 interface. The user should select only the parameters relevant to the specific card: T1 line code parameters for the MPH.1/T1 and E1 line code parameters for the MPH.1/E1. This parameter has the same values as dsx1LineCoding in T1/E1 MIB (RFC-1406). The parameters in dsx1LineCoding are: dsx1JBZS (1) dsx1B8ZS (2) dsx1HDB3 (3) dsx1ZBTSI (4) dsx1AMI (5) other (6)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER b7T1(1), b8zsT1(2), hdb3E1(4)  

prtExHs4LineLen 1.3.6.1.4.1.164.3.2.3.2.7.1.1.7
This attribute is the line length parameter used only for T1 interfaces. len399p533ft=len-399-533ft
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), len0p133ft(2), len134p266ft(3), len267p399ft(4), len400p533ft(5), len534p655ft(6), fcc68(7)  

prtExHs4RestoreT 1.3.6.1.4.1.164.3.2.3.2.7.1.1.8
Time passing from the disappearance of the loss of synchronization condition (red alarm), to the restoration of normal service.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER restoreT1secFast(2), restoreT10sec62411(3), ccittE1(4)  

prtExHs4OosSig 1.3.6.1.4.1.164.3.2.3.2.7.1.1.9
Out of Service signal type.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notsupported(2), forcedIdle(3), forcedBusy(4), busyIdle(5), idleBusy(6)  

prtExHs4OosCode 1.3.6.1.4.1.164.3.2.3.2.7.1.1.10
OOS Code
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notsupported(2), oosCode00H(3), oosCode1aH(4), oosCode54H(5), oosCode7eH(6), oosCode7fH(7), oosCode98H(8), oosCode9eH(9), oosCoded5H(10), oosCodee4H(11), oosCodeffH(12)  

prtExHs4IdleCode 1.3.6.1.4.1.164.3.2.3.2.7.1.1.11
Type value(00 - FF HEX), excluding 0H,8H,10H,12H,21H,24H, 42H,49H,84H,92H
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtExHs4MfClkSrcSlt 1.3.6.1.4.1.164.3.2.3.2.7.1.1.12
This attribute indicates whether the port Tx is multiframe synchronized with Rx multiframe of another port and the slot position of that port. This opration is required in order to bypass signaling of PCM voice channels. When its value is Local(2) there is no meaning to 'prtExHs4MfClkSrcPrt' parameter. In the ?004 Unit the entries io6(10)..io16) are not valid
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER local(2), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExHs4MfClkSrcPrt 1.3.6.1.4.1.164.3.2.3.2.7.1.1.13
A unique number to identify a port position in the mux if the MultiFrame clock source is valid (YES). inPrt1 - for MTML-H/E1 cards.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), inPrt1(101)  

prtExHs4TsCnfgTable 1.3.6.1.4.1.164.3.2.3.2.7.2
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExHs4TsEntry

prtExHs4TsEntry 1.3.6.1.4.1.164.3.2.3.2.7.2.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtExHs4TsEntry  

prtExHs4TsCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.7.2.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

prtExHs4TsSltIdx 1.3.6.1.4.1.164.3.2.3.2.7.2.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExHs4TsPrtIdx 1.3.6.1.4.1.164.3.2.3.2.7.2.1.3
This attribute indicates a unique port number. Hs4/T1 and Hs4/T1 cards have only one external interface.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER exPrt1(1)  

prtExHs4TsIdx 1.3.6.1.4.1.164.3.2.3.2.7.2.1.4
This attribute indicates a unique time slot position. The valid time slots are: 1..24 for T1 Card and 1..31 for E1 interface. In G732S-E1 lines, time slot 16 is not valid for data, it is dedicated to multiframe synchronization bits and voice signaling.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtExHs4TsIConSlot 1.3.6.1.4.1.164.3.2.3.2.7.2.1.5
This attribute indicates whether the specified time slot is connected/routed internally in the Agent and to which card it is connected. In the ?004 Unit the entries io6(10)..io16) are not valid. split - will be used when the Src TS is connected to more than one slot OR more than one port (each needing less than a whole TS).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noConnect(2), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), split(100)  

prtExHs4TsIConPrt 1.3.6.1.4.1.164.3.2.3.2.7.2.1.6
This attribute indicates the internally (In Mux) connected/routed port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6), exPrt7(7), exPrt8(8), exPrt9(9), exPrt10(10), exPrt11(11), exPrt12(12), noConnect(100)  

prtExHs4TsIConTs 1.3.6.1.4.1.164.3.2.3.2.7.2.1.7
This attribute indicates a unique time slot position. The valid time slots are: 1..24 for T1 Module and 1..31 for E1 interface. In G732S-E1 lines time slot 16 is not valid for data, it is dedicated for multiframe synchronization bits and voice signaling.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtExHsiCnfgTable 1.3.6.1.4.1.164.3.2.3.2.8.1
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExHsiCnfgEntry

prtExHsiCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.8.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtExHsiCnfgEntry  

prtExHsiCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.8.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

prtExHsiSltIdx 1.3.6.1.4.1.164.3.2.3.2.8.1.1.2
This attribute indicates a unique slot position where the card is inserted.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), notApplicable(255)  

prtExHsiPrtIdx 1.3.6.1.4.1.164.3.2.3.2.8.1.1.3
A unique port identifier within the card. For MP : 1..12 For DXC: 111 .. 2531. See DXC R6 spec for port index convention. For FCD-A, 'S' Interface external ports: 131, 141, 151, 161.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtExHsiConnect 1.3.6.1.4.1.164.3.2.3.2.8.1.1.4
This attribute indicates whether the port should be considered in any of the mux algorithms. v51 - this port is connected to a V5.1 interface. All rest of the values will be 'notApplicable' in this case. V5 MIB will be used instead. v52 - this port is connected to a V5.2 interface. All rest of the values will be 'notApplicable' in this case. V5 MIB will be used instead.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3), v51(4), v52(5)  

prtExHsiRate 1.3.6.1.4.1.164.3.2.3.2.8.1.1.5
This attribute indicates the port speed.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER r600bps(2), r1200bps(3), r2400bps(4), r4800bps(5), r9600bps(6), r19200bps(7), r38400bps(8), r48kbps(9), r56kbps(10), r64kbps(11), r128kbps(12), notApplicable(255)  

prtExHsiLinkTo 1.3.6.1.4.1.164.3.2.3.2.8.1.1.6
It indicates the slot of the main link card to which the HS-? card is mapped. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort.
Status: deprecated Access: read-write
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExHsiInterface 1.3.6.1.4.1.164.3.2.3.2.8.1.1.7
It indicates the interface type: lt = line termination nt = network termination te = terminal equipment. lt1 - for ASMi-31 connection (not ISDN) For MP: For HS-U/I only 'lt' and 'nt' are applicable. For HS-U/1 only 'lt' is applicable. For HS-S , only 'te' and 'nt' are applicable. For HS-U, this object is not applicable. For HS-U6, HS-U12, are applicable: 'lt'=lt-i,'nt'=nt-i, lt1. For DXC: For HS-U8, HS-U16, are applicable: 'lt'=LT-I,'nt'=NT-I, 'lt1'=LT-1.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER lt(1), nt(2), te(3), lt1(4), notApplicable(255)  

prtExHsiActType 1.3.6.1.4.1.164.3.2.3.2.8.1.1.8
It indicates the Activation Type. Activation Type is the Synchronization type towards the PBX. It is applicable only when prtExHsiInterface=nt. notApplicable - for cards that do not support this object, or when prtExHsiInterface is NOT nt.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), type1(2), type2(3), type3(4)  

prtInHsiCnfgTable 1.3.6.1.4.1.164.3.2.3.2.8.2
The write operation into the Table Objects is valid only to the TmpCnfg entry. This table is not applicable for MP-2100 HS-U card type.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtInHsiCnfgEntry

prtInHsiCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.8.2.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtInHsiCnfgEntry  

prtInHsiCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.8.2.1.1
This object indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

prtInHsiSltIdx 1.3.6.1.4.1.164.3.2.3.2.8.2.1.2
This object indicates a unique slot position where the card is inserted.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), notApplicable(255)  

prtInHsiPrtIdx 1.3.6.1.4.1.164.3.2.3.2.8.2.1.3
A unique port identifier within the card. Valid values for MP: inPrt1 (101) .. inPrt48 (148). Valid values for DXC: 11012.. 25316. See DXC R6 spec for port index convention.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtInHsiConnect 1.3.6.1.4.1.164.3.2.3.2.8.2.1.4
This attribute indicates whether the port should be considered in any of the mux algorithms.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtInHsiRate 1.3.6.1.4.1.164.3.2.3.2.8.2.1.5
This object indicates the port speed. For HS-U/I and HS-S ports: 2 bit - up to 9600bps 4 bit - 19200bps 8 bit - 38400bps .. 64kbps. concentrated - this D channel goes to a Concentration channel, that represents many channels that this value was selected for them. The Concentrated channel is an Internal D Channel of the same card. This value is applicable only for D channels, except Concentration channel itself. --for HS-S and HS-U/I cards the Concentration channel will always be: internal-13 --for MP-2200 HS-S12, HS-S6, HS-U12, HS-U6 and DXC HS-U8 and HS-U16 cards, the Concentration channel is selected via the prtInHsiConcentratedTo object. notConnected - same as prtInHsiConnect=no.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER r600bps(2), r1200bps(3), r2400bps(4), r4800bps(5), r9600bps(6), r19200bps(7), r38400bps(8), r48kbps(9), r56kbps(10), r64kbps(11), r128kbps(12), concentrated(13), notConnected(100), notApplicable(255)  

prtInHsiConcentratedTo 1.3.6.1.4.1.164.3.2.3.2.8.2.1.6
The Concentration D Channel of the prtInHsiPrtIdx port. The port always belongs to the same card as prtInHsiPrtIdx port. This object is applicable only when prtInHsiRate=concentrated. Valid values: - notApplicable: 255 - for MP-2200: HS-S12, HS-U12 cards: inPrt37 (137) .. inPrt48 (148). HS-S6, HS-U6 cards: inPrt19 (119) .. inPrt24 (124). - for DXC: HS-U8 cards: 112 .. 254 HS-U16 cards: 112 .. 258. See DXC R6 spec for port index convention.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtExHsrCnfgTable 1.3.6.1.4.1.164.3.2.3.2.10.1
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExHsrCnfgEntry

prtExHsrCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.10.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtExHsrCnfgEntry  

prtExHsrCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.10.1.1.1
This object indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

prtExHsrSltIdx 1.3.6.1.4.1.164.3.2.3.2.10.1.1.2
This object indicates a unique slot position where the card is inserted.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19)  

prtExHsrPrtIdx 1.3.6.1.4.1.164.3.2.3.2.10.1.1.3
A unique prt identifier within the card. Valid values: For MP: - For HS-R cards: exPrt1 (1) .. exPrt4 (4) - For HS-U/1 cards: inPrt1 (101) .. inPrt4 (104) - For HS-S12, HS-S6, HS-U12, HS-U6 cards: exPrt1 (1) .. exPrt12 (12). This MIB table is used only for LT-1 interface. For DXC: - For HS-U8, HS-U16 cards: 111 .. 2531 (See DXC R6 spec for port index convention). This MIB table is used only for LT-1 interface.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtExHsrConnect 1.3.6.1.4.1.164.3.2.3.2.10.1.1.4
This object indicates whether the port should be considered in any of the mux algorithms.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtExHsrProtocol 1.3.6.1.4.1.164.3.2.3.2.10.1.1.5
This object indicates the protocol.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER sync(2), async(3)  

prtExHsrRate 1.3.6.1.4.1.164.3.2.3.2.10.1.1.6
This object indicates the port speed. The 16,32,48,56,64 and 128 kbps rates are applicable only for Sync protocol. The 57.6 and 115.2 kbps rates are applicable only for Async protocol. notConnected= 0 rate.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER r600bps(2), r1200bps(3), r2400bps(4), r4800bps(5), r9600bps(6), r19200bps(7), r38400bps(8), r48kbps(9), r56kbps(10), r64kbps(11), r16000bps(12), r32000bps(13), r57600bps(14), r115200bps(15), r128000bps(16), r7200bps(17), r14400bps(18), r28800bps(19), notConnected(100)  

prtExHsrDataBits 1.3.6.1.4.1.164.3.2.3.2.10.1.1.7
Data Bits. This object is applicable for Async protocol only.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER d5bits(1), d6bits(2), d7bits(3), d8bits(4), notApplicable(255)  

prtExHsrParity 1.3.6.1.4.1.164.3.2.3.2.10.1.1.8
- For HS-R card, this object indicates if the parity bit is needed or not. Therefore, the 'no' and 'yes; values are applicable. - For HS-S12, HS-U12, the parity type is selected: no, odd, even. This object is applicable for Async protocol only.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3), odd(4), even(5), notApplicable(255)  

prtExHsrStopBits 1.3.6.1.4.1.164.3.2.3.2.10.1.1.9
This object indicates the minimum number of stop bits in the tx async frame. This object is applicable for Async protocol only.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER stopBits1Bit(1), stopBits2Bits(2), notApplicable(255)  

prtExHsrCts 1.3.6.1.4.1.164.3.2.3.2.10.1.1.10
CTS. This object is applicable for Async protocol only.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER on(2), rts(3), notApplicable(255)  

prtExHsrClkMode 1.3.6.1.4.1.164.3.2.3.2.10.1.1.11
Clock mode. This object is applicable for Sync protocol only.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER dce(1), extDce(2), notApplicable(255)  

prtExHsrLinkTo 1.3.6.1.4.1.164.3.2.3.2.10.1.1.12
It indicates the slot of the main link card to which the HS-R card is mapped. notApplicable - for HS-U/1 internal ports. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort.
Status: deprecated Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExHsrDcdDsr 1.3.6.1.4.1.164.3.2.3.2.10.1.1.13
DCD & DSR.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), local(2), endToEnd(3)  

prtExHsrOperMode 1.3.6.1.4.1.164.3.2.3.2.10.1.1.14
This object indicates the operation mode of the port. normal = bi-directional (Tx/Rx) unidirectRx = unidirectional Rx. broadcast = Tx upon request.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER normal(2), unidirectRx(3), broadcast(4)  

prtExHsrRtsDtr 1.3.6.1.4.1.164.3.2.3.2.10.1.1.15
RTS & DTR.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), local(2), endToEnd(3)  

prtExHsrLlbEnable 1.3.6.1.4.1.164.3.2.3.2.10.1.1.16
Enable/Disable LLB.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

prtExHsrRlbEnable 1.3.6.1.4.1.164.3.2.3.2.10.1.1.17
Enable/Disable RLB.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

prtExHsrRateAdapt 1.3.6.1.4.1.164.3.2.3.2.10.1.1.18
Rate Adaptation - takes a low rate and adapts it to 64Kbps. This object specifies the means this adaptation is done by.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), proprietary(2), v110(3)  

prtExHsrRemoteModem 1.3.6.1.4.1.164.3.2.3.2.10.1.1.19
Remote modem. asmi31s2 = ASMi-31/2
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), asmi31(2), asmi31s2(3)  

prtExHsrEncapsMode 1.3.6.1.4.1.164.3.2.3.2.10.1.1.20
Low Speed encapsulation method over PCM. When Encapsulation mode is Latency optimized, only rates up to 19.2 are supported. In this case a double number of bits occupy the Time Slot. For up to 9.6 Kbps - 4 bits are occupied. For 14.4 & 19.2 Kbps - 8 bits are occupied. When Encapsulation Mode is Bandwidth Optimized: For up to 9.6 Kbps - 2 bits are occupied. For 14.4 & 19.2 Kbps - 4 bits are occupied. For higher rates - 8 bits are occupied.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), bwOptimized(2), latencyOptimized(3), asmi31(4)  

prtExMbeCnfgTable 1.3.6.1.4.1.164.3.2.3.2.11.1
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExMbeCnfgEntry

prtExMbeCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.11.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtExMbeCnfgEntry  

prtExMbeCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.11.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

prtExMbeSltIdx 1.3.6.1.4.1.164.3.2.3.2.11.1.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExMbePrtIdx 1.3.6.1.4.1.164.3.2.3.2.11.1.1.3
A unique port identifier within the card.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER exPrt1(1)  

prtExMbeLan 1.3.6.1.4.1.164.3.2.3.2.11.1.1.4
This attribute indicates whether the MBE port is operated as main or remote bridge.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER remote(1), main(2)  

prtInMbeCnfgTable 1.3.6.1.4.1.164.3.2.3.2.11.2
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtInMbeCnfgEntry

prtInMbeCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.11.2.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtInMbeCnfgEntry  

prtInMbeCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.11.2.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

prtInMbeSltIdx 1.3.6.1.4.1.164.3.2.3.2.11.2.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtInMbePrtIdx 1.3.6.1.4.1.164.3.2.3.2.11.2.1.3
A unique port identifier within the card.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER inPrt1(101)  

prtInMbeConnect 1.3.6.1.4.1.164.3.2.3.2.11.2.1.4
This attribute indicates whether the port should be considered in any of the mux algorithms.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtInMbeRate 1.3.6.1.4.1.164.3.2.3.2.11.2.1.5
This attribute indicates the port speed.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER r1x64eq64Kbps(1), r2x64eq128Kbps(2), r3x64eq192Kbps(3), r4x64eq256Kbps(4), r5x64eq320Kbps(5), r6x64eq384Kbps(6), r7x64eq448Kbps(7), r8x64eq512Kbps(8), r9x64eq576Kbps(9), r10x64eq640Kbps(10), r11x64eq704Kbps(11), r12x64eq768Kbps(12), r13x64eq832Kbps(13), r14x64eq896Kbps(14), r15x64eq960Kbps(15), r16x64eq1024Kbps(16), r17x64eq1088Kbps(17), r18x64eq1152Kbps(18), r19x64eq1216Kbps(19), r20x64eq1280Kbps(20), r21x64eq1344Kbps(21), r22x64eq1408Kbps(22), r23x64eq1472Kbps(23), r24x64eq1536Kbps(24)  

prtInMbeLinkTo 1.3.6.1.4.1.164.3.2.3.2.11.2.1.6
It indicates the slot of the main link card to which the MBE card is mapped. In the ?004 Unit the entries io6(10)..io16) are not valid. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort.
Status: deprecated Access: read-write
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExTreCnfgTable 1.3.6.1.4.1.164.3.2.3.2.12.1
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExTreCnfgEntry

prtExTreCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.12.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtExTreCnfgEntry  

prtExTreCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.12.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

prtExTreSltIdx 1.3.6.1.4.1.164.3.2.3.2.12.1.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExTrePrtIdx 1.3.6.1.4.1.164.3.2.3.2.12.1.1.3
A unique port identifier within the card.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER exPrt1(1)  

prtExTreLan 1.3.6.1.4.1.164.3.2.3.2.12.1.1.4
This attribute indicates whether the TRE port is operated as main or remote bridge. Default=remote.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER remote(1), main(2)  

prtExTreLanRate 1.3.6.1.4.1.164.3.2.3.2.12.1.1.5
This attribute indicates the Rate of the TRE port in Mbit/sec. Default-r4M.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER r4M(1), r16M(2)  

prtInTreCnfgTable 1.3.6.1.4.1.164.3.2.3.2.12.2
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtInTreCnfgEntry

prtInTreCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.12.2.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtInTreCnfgEntry  

prtInTreCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.12.2.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

prtInTreSltIdx 1.3.6.1.4.1.164.3.2.3.2.12.2.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtInTrePrtIdx 1.3.6.1.4.1.164.3.2.3.2.12.2.1.3
A unique port identifier within the card.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER inPrt1(101)  

prtInTreConnect 1.3.6.1.4.1.164.3.2.3.2.12.2.1.4
This attribute indicates whether the port should be considered in any of the mux algorithms.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtInTreRate 1.3.6.1.4.1.164.3.2.3.2.12.2.1.5
This attribute indicates the port speed.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER r1x56eq56Kbps(1), r1x64eq64Kbps(2), r2x56eq112Kbps(3), r2x64eq128Kbps(4), r3x56eq168Kbps(5), r3x64eq192Kbps(6), r4x56eq224Kbps(7), r4x64eq256Kbps(8), r5x56eq280Kbps(9), r5x64eq320Kbps(10), r6x56eq336Kbps(11), r6x64eq384Kbps(12), r7x56eq392Kbps(13), r7x64eq448Kbps(14), r8x56eq448Kbps(15), r8x64eq512Kbps(16), r9x56eq504Kbps(17)  

prtInTreLinkTo 1.3.6.1.4.1.164.3.2.3.2.12.2.1.6
It indicates the slot of the main link card to which the MBE card is mapped. In the ?004 Unit the entries io6(10)..io16) are not valid. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort.
Status: deprecated Access: read-write
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExPVc4CnfgTable 1.3.6.1.4.1.164.3.2.3.2.9.1
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExPVc4CnfgEntry

prtExPVc4CnfgEntry 1.3.6.1.4.1.164.3.2.3.2.9.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtExPVc4CnfgEntry  

prtExPVc4CnfgIdx 1.3.6.1.4.1.164.3.2.3.2.9.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

prtExPVc4SltIdx 1.3.6.1.4.1.164.3.2.3.2.9.1.1.2
This attribute indicates a unique slot position where the card is inserted.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtExPVc4PrtIdx 1.3.6.1.4.1.164.3.2.3.2.9.1.1.3
This object indicates the port number in the selected card (slot).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), inPrt1(101), inPrt2(102), inPrt3(103), inPrt4(104), inPrt5(105), inPrt6(106), inPrt7(107), inPrt8(108)  

prtExPVc4PrtType 1.3.6.1.4.1.164.3.2.3.2.9.1.1.4
This object indicates the type of the selected port. In Mx 30/300 phase 4: s0 & u are for Voice over ISDN. In MX 30/300 phase 5: sQsig & uQsig are used for Voice over ISDN with Qsig option. In MX MVC4 voice cards, each pair of ports 1-2, 3-4 may have a different type: E&M, FXO, FXS. In MVC4 compressed voice cards ports 1..4 have the same interface for all ports. In MVC8 compressed voice cards each group of ports 1..4, 5..8 may have a different type: E&M, FXO, FXS.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER eAndM(1), fxo(2), fxs(3), internal(4), s0(5), u(6), sQsig(7), uQsig(8)  

prtExPVc4Connect 1.3.6.1.4.1.164.3.2.3.2.9.1.1.5
This attribute indicates whether the port should be considered in any of the mux algorithms.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtExPVc4IfType 1.3.6.1.4.1.164.3.2.3.2.9.1.1.6
This attribute indicates the interface type of the port. eAndM4wires and eAndM2wires - are valid only for E&M port type eAndM4wires - means 2/4 wires fxoGnd and fxoLoop - are valid only for FXO port type fxsGnd and fxsLoop - are valid only for FXS port type e1Framer, e1Slave, t1Framer, t1Slave - are applicable for the mvc4Pbx cards only.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), eAndM4wires(2), eAndM2wires(3), fxoGnd(4), fxoLoop(5), fxsGnd(6), fxsLoop(7), e1Framer(8), e1Slave(9), t1Framer(10), t1Slave(11)  

prtExPVc4TxGain 1.3.6.1.4.1.164.3.2.3.2.9.1.1.7
Transmission gain in dB.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtExPVc4RxGain 1.3.6.1.4.1.164.3.2.3.2.9.1.1.8
Reception gain in dBm.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtExPVc4MaxRate 1.3.6.1.4.1.164.3.2.3.2.9.1.1.9
Voice rate.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notConnected(1), r4800bps(2), r7200bps(3), r9600bps(4), notApplicatble(255)  

prtExPVc4Tc 1.3.6.1.4.1.164.3.2.3.2.9.1.1.10
Time interval for CIR control, in seconds. The value will be the same for all cards' ports.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER t1sec(1), t2sec(2), t3sec(3), t4sec(4)  

prtExPVc4Oos 1.3.6.1.4.1.164.3.2.3.2.9.1.1.11
Handling type, when connection is lost.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notSupported(2), forcedIdle(3), forcedBusy(4), busyIdle(5), idleBusy(6)  

prtExPVc4EchoCanceler 1.3.6.1.4.1.164.3.2.3.2.9.1.1.12
Echo canceler activation.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtExPVc4VarDelay 1.3.6.1.4.1.164.3.2.3.2.9.1.1.13
Maximum variant delay of the FR network, in msec.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..300  

prtExPVc4CongLevel 1.3.6.1.4.1.164.3.2.3.2.9.1.1.14
This object indicates the level of delayed data in precents of total available dynamic memory, for which the port will start to operate as congested. The resolution of the parameter is 5%.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..70  

prtExPVc4Wire 1.3.6.1.4.1.164.3.2.3.2.9.1.1.15
This object indicates the wiring of the E&M port. It is applicable only for E&M card type.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER w2wire(1), w4wire(2), notApplicable(255)  

prtExPVc4ExtensionType 1.3.6.1.4.1.164.3.2.3.2.9.1.1.16
This object indicates the type of extension relevant for this port. ipForceConnect (6) is used for automatic connection or automatic dialing when the phone is off hook (hot line). permanentDial (7) means that the call is established upon power up. The hook may be on or off. Permanent Dialing can be used when there is no signaling. autoAccept (8) means that the called party in the Permanent Dialing will accept the call from the remote side automatically upon on or off hook.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), forceConnect(2), voiceSwitching(3), transparent(4), transparentPlus(5), ipForceConnect(6), permanentDial(7), autoAccept(8)  

prtExPVc4ExtensionNumber 1.3.6.1.4.1.164.3.2.3.2.9.1.1.17
This is the extension number of this port. This field is relevant only when the extension type is voice switching and is read only if the port is member of a hunt group.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(2)  

prtExPVc4OutPulsing 1.3.6.1.4.1.164.3.2.3.2.9.1.1.18
This field indicates whether to outpulse the received digits. It is notApplicable(1) when the extension type is forceConnect(2).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

prtExPVc4HuntGroupMb 1.3.6.1.4.1.164.3.2.3.2.9.1.1.19
This object indicates if this port belongs to an hunt group.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

prtExPVc4HuntGroupIdx 1.3.6.1.4.1.164.3.2.3.2.9.1.1.20
If it belongs to an hunt group, this fields indicates the index of the relevant hunt group. 0 = notApplicable
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..10  

prtExPVc4AutoFaxMode 1.3.6.1.4.1.164.3.2.3.2.9.1.1.21
This object indicates if the system will switch automatically to FAX mode when detecting FAX activity. Default=Yes.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

prtExPVc4FaxRate 1.3.6.1.4.1.164.3.2.3.2.9.1.1.22
FAX initial rate. Default=9600 bps.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notConnected(1), r4800bps(2), r7200bps(3), r9600bps(4), r12000bps(5), r14400bps(6), r2400bps(7), vbdFax(8)  

prtExPVc4SeizeAck 1.3.6.1.4.1.164.3.2.3.2.9.1.1.23
This parameter shows whether the device will acknowledge a seize signal (On/Off Hook). When the value is set to yes(3) & the device receives an on/off hook signal it will transmit back an on/off hook signal. When the value is set to no(2) & the device receives an on/off hook signal it will NOT transmit back an on/off hook signal. Example: If Seize Ack Parameter = YES, when the MVC.4 receives a seize signal (Off Hook) from the PBX it will send an Off Hook to the PBX. The Seize Parameter is relevant for all the following cards: MVC-4 MVC-4/E1-Framer MVC-4/T1-DSU-Framer MVC-4/T1-CSU-Framer MVC-4/E1-SLAVE MVC-4/T1-SLAVE Default values: Analog FXS - No (value can't be changed). Analog FXO - Yes (value can't be changed). Analog E&M - No (values NO/YES). Digital E1/T1 Framer & Slave - No.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtExPVc4SignalingProtocol 1.3.6.1.4.1.164.3.2.3.2.9.1.1.24
The signaling protocol that will be used between the PABX & the voice port. Delay Start Protocol: the line is seized by sending an Off hook signal and after a delay, if the called party is available (On hook) DTMF (Dual Tone Multi Frequency) digits are sent towards the called party. Immediate Start Protocol: the line is seized by sending an Off Hook signal and immediately DTMF digits are sent towards the called party. Wink start protocol: the line is seized by sending an Off Hook signal and then the called party sends a short Off Hook wink signal. Now the calling party starts sending DTMF digits.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER delayStart(2), immediateStart(3), winkStart(4)  

prtExPVc4DelayStart 1.3.6.1.4.1.164.3.2.3.2.9.1.1.25
This parameter is used only for Delay Protocol. This is the time that the calling party will wait after sending an Off hook signal and before sending DTMF digits to the called party. The delay values are 100..5000 msec in intervals of 100 msec.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtExPVc4WinkMinDuration 1.3.6.1.4.1.164.3.2.3.2.9.1.1.26
This parameter is used only for Wink Protocol. Min Duration of the Wink Signal (off hook duration from the called party). Legal values: 40..400 msec in intervals of 10 msec.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtExPVc4WinkMaxDuration 1.3.6.1.4.1.164.3.2.3.2.9.1.1.27
This parameter is used only for Wink Protocol. Max Duration of the Wink Signal (off hook duration from the called party). Legal values: 40..400 msec in intervals of 10 msec.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtExPVc4GenerateTone 1.3.6.1.4.1.164.3.2.3.2.9.1.1.28
This parameter indicates whether the device (MX or MPH) should generate dial tones for the channel. If the value is yes (3), it generates dial tones. If the value is no (2), the connected equipment will generate dial tones. For example for some ISDN sets the dial tone is generated by the phone itself while for others sets it is generated by the MX.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

prtExPVc4CodingLaw 1.3.6.1.4.1.164.3.2.3.2.9.1.1.29
This attribute indicates the Method/Law for decoding/encoding the voice information. aLaw(1) is the standard Law for E1 links. uLaw(2) is the standard Law for T1 links. This object is equal for all the ports in the specific module because of HW limitations
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER aLAW(1), uLAW(2)  

prtExPVc4GenerateRingBack 1.3.6.1.4.1.164.3.2.3.2.9.1.1.30
Determines whether the Ring Back tone is generated locally or from the remote end. The default is - NO (Meaning coming from the remote end). Yes means that the Ring Back Tone is generated locally. Applicable only for Force Connect.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

prtExPVc4ChannelId 1.3.6.1.4.1.164.3.2.3.2.9.1.1.31
Channel Identifier. According to FRF11 each voice port that works as force connect should add a CH Id after the DLCI in the frame header. Default : 1 Applicable only for Force Connect. Not Applicable value will be 0.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..256  

prtExPVc4PortConnection 1.3.6.1.4.1.164.3.2.3.2.9.1.1.32
Port connection determines whether the port is connected to a PABX (Trunk) or to Telephone set (Line) . It determines whether to send certain messages to the port or not. If the type is LINE then the port generates a ring back tone , if TRUNK it doesn't (The PBX does it).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), line(2), trunk(3)  

prtExPVc4CoderAndRate 1.3.6.1.4.1.164.3.2.3.2.9.1.1.33
Coder and Rate for the Voice Compression. In MPH: Relevant for MVC-8 card only.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), g7231r6300BPS(2), g7231r5300BPS(3), g729A8KBPS(4), g711aLAW(5), g711uLAW(6), g726r16KBPS(7), g726r24KBPS(8), g726r32KBPS(9), g726r40KBPS(10), g727r16KBPS(11), g727r24r16KBPS(12), g727r24KBPS(13), g727r16r32KBPS(14), g727r32r24KBPS(15), g727r32KBPS(16), g727r40r16KBPS(17), g727r40r24KBPS(18), g727r40r32KBPS(19), transparent(20), netcoder6400BPS(21), netcoder7200BPS(22), netcoder8KBPS(23), netcoder8800BPS(24), netcoder9600BPS(25), lowBitRateR2660BPS(26), amr4750BPS(27), amr5150BPS(28), amr5900BPS(29), amr6700BPS(30), amr7400BPS(31), amr7950BPS(32), amr10200BPS(33), amr12200BPS(34)  

prtExPVc4DestinationNum 1.3.6.1.4.1.164.3.2.3.2.9.1.1.34
The destination phone number: 0 to 22 digits. Applicable for Auto Dial - ipForceConnect(6), Permanent Dial and Auto Accept Extension Types. Default: Null String
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

prtExPVc4DtmfRelay 1.3.6.1.4.1.164.3.2.3.2.9.1.1.35
When DTMF RELAY is disabled, the DTMF digits (dialed by the user) are transmitted as compressed voice and in the remote unit are decompressed. When DTMF RELAY is enabled, the DTMF digits are detected at the near side and not transmitted as voice. Instead, only an indication of what digits were dialed are transmitted and in the far end the tone is regenerated.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(2), enable(3)  

prtExPVc4DiscOnSilence 1.3.6.1.4.1.164.3.2.3.2.9.1.1.36
No. of silenced seconds after which the call will be disconected. A value of 0 means that there will be no disconnect when there is silence. Possible values: 0 - 900 sec.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtExPVc4DynamicJitter 1.3.6.1.4.1.164.3.2.3.2.9.1.1.37
The MVC8 uses two mechanisms to overcome the network delay. The first one is a static jitter buffer which holds a constant buffer of up to 300 Msec and can be controled by the JITTER parameter (prtExPVc4VarDelay). The second one is the dynamic jitter which calculates, in real time, the network delay and handles a jitter buffer dynamically. The dynamic mechanism that is implemented in MVC8, was intended to overcome network delay yet when the network bursts, the MVC8 dynamic mechanism is not able to overcome the delay. Therefore it is better not to use the dynamic jitter (DISABLE - should be the default) where bursts may occur often.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(2), enable(3)  

prtExPVc4EandMType 1.3.6.1.4.1.164.3.2.3.2.9.1.1.38
This is the signaling type on the E&M analog side. The analog signaling includes voltage, no. of pins and other parameters.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), type1(2), type2(3), type3(4), ssdc5(5)  

prtExPVc4Rate 1.3.6.1.4.1.164.3.2.3.2.9.1.1.39
This is the Rate of the port in TS units. It is used by VF-30 card family. 0 = NA = port is not intended to be connected; therefore, no Rate.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..31  

prtExPVc4FrameSize 1.3.6.1.4.1.164.3.2.3.2.9.1.1.40
Defines the maximum size in Bytes of the multiplexed frame. In some cases this must be limited to avoid IP fragmentation, which makes the multiplexing useless, and can also decrease the damage in case of frame loss. Valid range: 100..1461. notApplicable=0.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtExPVc4MultiplexInterval 1.3.6.1.4.1.164.3.2.3.2.9.1.1.41
Defines the maximum amout of time (msec.) between multiplexed frames that are sent. For Vmux-400/420 devices: It defines the Payload Packetizing Interval. Valid values: 10-90 msec. notApplicable=0.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtExPVc4TransportProtocol 1.3.6.1.4.1.164.3.2.3.2.9.1.1.42
Transport Protocol. ptp = point to point. aal2oMpls = AAL2 over MPLS.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), ptp(2), aal2oMpls(3)  

prtExPVc4MultiFreqRelay 1.3.6.1.4.1.164.3.2.3.2.9.1.1.43
This object enables/disables Multi Frequency Signaling Detection.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

prtExPVc4MinPulseWidth 1.3.6.1.4.1.164.3.2.3.2.9.1.1.44
Defines the minimum Pulse Width in msec. Valid values: 45-100 msec. notApplicable=0.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtExPVc4MinPowerLevel 1.3.6.1.4.1.164.3.2.3.2.9.1.1.45
Defines the minimum Power Level in dBm. Valid values: -1..-35 dBm.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtExPVc4SuperTandem 1.3.6.1.4.1.164.3.2.3.2.9.1.1.46
The Super Tandem feature provides end to end compression over multiple hops, solving the double compression problem detected in Voice compressing systems. The Super Tandem, when enabled, allows transmission of compressed voice between a few devices and eliminates the need to decompress an recompress it over each voice card and PBX, thus improving voice quality and reducing delay.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

prtExPVc4DestIp 1.3.6.1.4.1.164.3.2.3.2.9.1.1.47
This object defines the destination IP Address.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

prtExPVc4DestBundle 1.3.6.1.4.1.164.3.2.3.2.9.1.1.48
This object defines the destination Bundle at the far-end device.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtExPVc4SrcIpAddress 1.3.6.1.4.1.164.3.2.3.2.9.1.1.49
This object defines the Source IP Address.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

prtExPVc4SrcIpMask 1.3.6.1.4.1.164.3.2.3.2.9.1.1.50
This object defines the Source IP Mask.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

prtExPVc4DefaultGateway 1.3.6.1.4.1.164.3.2.3.2.9.1.1.51
This object defines the Default Gateway for this interface.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

prtExPVc4SigPacketInterval 1.3.6.1.4.1.164.3.2.3.2.9.1.1.52
Defines the Signaling Packetizing Interval, which is the maximum time interval, measured in msec (milliseconds), between multiplexed signaling frames.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

prtExPVc4DlciTable 1.3.6.1.4.1.164.3.2.3.2.9.2
The write operation into the Table Objects is valid only at the TmpCnfg entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExPVc4DlciEntry

prtExPVc4DlciEntry 1.3.6.1.4.1.164.3.2.3.2.9.2.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtExPVc4DlciEntry  

prtExPVc4DlciCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.9.2.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

prtExPVc4DlciSltIdx 1.3.6.1.4.1.164.3.2.3.2.9.2.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtExPVc4DlciPrtIdx 1.3.6.1.4.1.164.3.2.3.2.9.2.1.3
This attribute indicates a unique internal port number. VC4 cards have four external ports.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4)  

prtExPVc4DlciValid 1.3.6.1.4.1.164.3.2.3.2.9.2.1.4
This attribute indicates whether the attributes in this entry are valid or not. The user can add/delete pvc (dlci to dlci connection) by modifing this object
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtExPVc4DlciIConSlt 1.3.6.1.4.1.164.3.2.3.2.9.2.1.5
This attribute indicates a unique slot position In the Mux (Agent) where the dlci is routed to. In the ?004 Unit the entries io6(10)..io16) are not valid
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noConnect(2), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtExPVc4DlciIConPrt 1.3.6.1.4.1.164.3.2.3.2.9.2.1.6
This attribute indicates a unique port id which the dlci is routed to.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6), exPrt7(7), exPrt8(8), exPrt9(9), exPrt10(10), noConnect(100), inPrt1(101), inPrt2(102), inPrt3(103), inPrt4(104), inPrt5(105), inPrt6(106), inPrt7(107), inPrt8(108), inPrt9(109), inPrt10(110), inPrt11(111), inPrt12(112)  

prtExPVc4DlciIConDlci 1.3.6.1.4.1.164.3.2.3.2.9.2.1.7
This attribute indicates a unique internal connection dlci number, the dlci is routed to.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..991  

prtExPVc4DlciTxBc 1.3.6.1.4.1.164.3.2.3.2.9.2.1.8
This attribute indicates a unique Tx committed bandwidth on the user transmit line (or at the port receive line).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER full(1), zero(2), txBc9600bps(3), txBc14400bps(4), txBc19200bps(5), txBc28800bps(6), txBc32000bps(7), txBc38400bps(8), txBc48000bps(9), txBc56000bps(10), txBc57600bps(11), txBc64Kbps(12), txBc128Kbps(13), txBc192Kbps(14), txBc256Kbps(15), txBc320Kbps(16), txBc384Kbps(17), txBc448Kbps(18), txBc512Kbps(19), txBc768Kbps(20), txBc1024Kbps(21), txBc16000bps(25), txBc112Kbps(26)  

prtExPVc4DlciTxBe 1.3.6.1.4.1.164.3.2.3.2.9.2.1.9
This attribute indicates a unique Tx excess bandwidth on the user transmit line (or at the port receive line).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER full(1), zero(2), txBe9600bps(3), txBe14400bps(4), txBe19200bps(5), txBe28800bps(6), txBe32000bps(7), txBe38400bps(8), txBe48000bps(9), txBe56000bps(10), txBe57600bps(11), txBe64Kbps(12), txBe128Kbps(13), txBe192Kbps(14), txBe256Kbps(15), txBe320Kbps(16), txBe384Kbps(17), txBe448Kbps(18), txBe512Kbps(19), txBe768Kbps(20), txBe1024Kbps(21), txBc16000bps(25), txBc112Kbps(26)  

prtExPVc4DlciRxBc 1.3.6.1.4.1.164.3.2.3.2.9.2.1.10
This attribute indicates a unique Rx committed bandwidth on the user receive line (or at the port transmit line).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER full(1), zero(2), rxBc9600bps(3), rxBc14400bps(4), rxBc19200bps(5), rxBc28800bps(6), rxBc32000bps(7), rxBc38400bps(8), rxBc48000bps(9), rxBc56000bps(10), rxBc57600bps(11), rxBc64Kbps(12), rxBc128Kbps(13), rxBc192Kbps(14), rxBc256Kbps(15), rxBc320Kbps(16), rxBc384Kbps(17), rxBc448Kbps(18), rxBc512Kbps(19), rxBc768Kbps(20), rxBc1024Kbps(21), rxBc16000bps(25), rxBc112Kbps(26)  

prtExPVc4DlciRxBe 1.3.6.1.4.1.164.3.2.3.2.9.2.1.11
This attribute indicates a unique Rx excess bandwidth on the user receive line (or at the port transmit line).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER full(1), zero(2), rxBe9600bps(3), rxBe14400bps(4), rxBe19200bps(5), rxBe28800bps(6), rxBe32000bps(7), rxBe38400bps(8), rxBe48000bps(9), rxBe56000bps(10), rxBe57600bps(11), rxBe64Kbps(12), rxBe128Kbps(13), rxBe192Kbps(14), rxBe256Kbps(15), rxBe320Kbps(16), rxBe384Kbps(17), rxBe448Kbps(18), rxBe512Kbps(19), rxBe768Kbps(20), rxBe1024Kbps(21), rxBc16000bps(25), rxBc112Kbps(26)  

prtExPVc4DlciPriority 1.3.6.1.4.1.164.3.2.3.2.9.2.1.12
This attribute indicates a unique priority of the pvc. 6 is the lowest priority and 8 is the highest priority.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 6..8  

prtExPVc4DlciStatus 1.3.6.1.4.1.164.3.2.3.2.9.2.1.13
This attribute indicates the status of the pvc. The status is disconnected(1) when one of the sides is programmed as not connected
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER disconnected(1), connected(2)  

prtExLs6CnfgTable 1.3.6.1.4.1.164.3.2.3.2.13.1
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExLs6CnfgEntry

prtExLs6CnfgEntry 1.3.6.1.4.1.164.3.2.3.2.13.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtExLs6CnfgEntry  

prtExLs6CnfgIdx 1.3.6.1.4.1.164.3.2.3.2.13.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

prtExLs6SltIdx 1.3.6.1.4.1.164.3.2.3.2.13.1.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtExLs6PrtIdx 1.3.6.1.4.1.164.3.2.3.2.13.1.1.3
This attribute indicates a unique port index.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6), exPrt7(7), exPrt8(8), exPrt9(9), exPrt10(10), exPrt11(11), exPrt12(12)  

prtExLs6Connect 1.3.6.1.4.1.164.3.2.3.2.13.1.1.4
This attribute indicates whether the port should be considered in any of the mux algorithms.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtExLs6Protocol 1.3.6.1.4.1.164.3.2.3.2.13.1.1.5
This attribute indicates the protocol. async - can be selected only for ports 1-2.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER sync(2), async(3)  

prtExLs6Rate 1.3.6.1.4.1.164.3.2.3.2.13.1.1.6
Port rates in bps. g1 - contains the values : (2)-(6),(9),(12),(16) g2 - contains the values : (7),(10),(14),(19) g3 - contains the values : (8),(11),(13),(15),(17),(18),(20); it is not applicable when using Async protocol. Rates of pair ports (1-2, 3-4, 5-6) must be from the same group.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER r300bps(2), r600bps(3), r1200bps(4), r2400bps(5), r4800bps(6), r7200bps(7), r8000bps(8), r9600bps(9), r14400bps(10), r16000bps(11), r19200bps(12), r24000bps(13), r28800bps(14), r32000bps(15), r38400bps(16), r48000bps(17), r56000bps(18), r57600bps(19), r64000bps(20)  

prtExLs6ClkMode 1.3.6.1.4.1.164.3.2.3.2.13.1.1.7
This attribute indicates a unique port operation clock mode. It is applicable for Sync protocol only .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER dce(1), extDce(2), dte1(3), notApplicable(255)  

prtExLs6CtrlSignal 1.3.6.1.4.1.164.3.2.3.2.13.1.1.8
Control Signal.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER local(2), rts(3), dtrAndRts(4)  

prtExLs6DataBits 1.3.6.1.4.1.164.3.2.3.2.13.1.1.9
Data Bits. This object is applicable for Async protocol only.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER d6bits(1), d7bits(2), d8bits(3), d9bits(4), notApplicable(255)  

prtExLs6Cts 1.3.6.1.4.1.164.3.2.3.2.13.1.1.10
This object indicates the CTS control line operation mode.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), on(2), rts(3)  

prtExLs6LinkToInternal 1.3.6.1.4.1.164.3.2.3.2.13.1.1.11
This object indicates which internal port of the card, the external port is linked to.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER inPrt1(101), inPrt2(102), notApplicable(255)  

prtExLs6VCnfgTable 1.3.6.1.4.1.164.3.2.3.2.13.2
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExLs6VCnfgEntry

prtExLs6VCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.13.2.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtExLs6VCnfgEntry  

prtExLs6VCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.13.2.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

prtExLs6VSltIdx 1.3.6.1.4.1.164.3.2.3.2.13.2.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExLs6VPrtIdx 1.3.6.1.4.1.164.3.2.3.2.13.2.1.3
A unique identifier of the port, within the card.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER exPrt7(7), exPrt8(8)  

prtExLs6VConnect 1.3.6.1.4.1.164.3.2.3.2.13.2.1.4
This attribute indicates whether the port should be considered in any of the mux algorithms.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtExLs6VRate 1.3.6.1.4.1.164.3.2.3.2.13.2.1.5
Rate (bps) used for FAX transmission and Voice coding.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER r6400bps(2), r7200bps(3), r8000bps(4), r9600bps(5), r16000bps(6), r24000bps(7), r32000bps(8), r64000bps(9)  

prtExLs6VEchoCanceler 1.3.6.1.4.1.164.3.2.3.2.13.2.1.6
Echo canceler activation.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtExLs6VIfType 1.3.6.1.4.1.164.3.2.3.2.13.2.1.7
This attribute indicates the interface type of the port. w4wire - is applicable only for E&M port type.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER w2wire(1), w4wire(2)  

prtExLs6VTxGain 1.3.6.1.4.1.164.3.2.3.2.13.2.1.8
Transmit gain in dBm. E&M - values range: -17 .. 8 FXO - values range: -16 .. 4 FXS - values range: -13 .. 8
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtExLs6VRxGain 1.3.6.1.4.1.164.3.2.3.2.13.2.1.9
Receive gain in dBm. E&M - values range: -17 .. 2 FXO - values range: -17 .. -1 FXS - values range: -17 .. 2
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtExLs6VOos 1.3.6.1.4.1.164.3.2.3.2.13.2.1.10
Out of Service signaling mode.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER forcedIdle(1), forcedBusy(2), busyIdle(3), idleBusy(4)  

prtInLs6CnfgTable 1.3.6.1.4.1.164.3.2.3.2.13.3
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtInLs6CnfgEntry

prtInLs6CnfgEntry 1.3.6.1.4.1.164.3.2.3.2.13.3.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtInLs6CnfgEntry  

prtInLs6CnfgIdx 1.3.6.1.4.1.164.3.2.3.2.13.3.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

prtInLs6SltIdx 1.3.6.1.4.1.164.3.2.3.2.13.3.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtInLs6PrtIdx 1.3.6.1.4.1.164.3.2.3.2.13.3.1.3
This attribute indicates a unique internal port index.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER inPrt1(101), inPrt2(102)  

prtInLs6Connect 1.3.6.1.4.1.164.3.2.3.2.13.3.1.4
This attribute indicates whether the port should be considered in any of the mux algorithms. It also affects all the module considerations because the module has only one Internal interface which is the composite channel.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtInLs6TandemMode 1.3.6.1.4.1.164.3.2.3.2.13.3.1.5
This object indicates the Tandem Mode. tandemSlave - is valid only for an LS-6 card having on the (current slot-1) an LS-6 card with 'tandemMaster' mode.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noTandem(1), tandemMaster(2), tandemSlave(3)  

prtInLs6Rate 1.3.6.1.4.1.164.3.2.3.2.13.3.1.6
Main Rate in Kbps.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER r32Kbps(1), r56Kbps(2), r64Kpbs(3), r128Kbps(4), r256Kbps(5), r384Kbps(6), r192Kbps(7), r512Kbps(8), r768Kbps(9), r14400bps(10)  

prtInLs6RemoteType 1.3.6.1.4.1.164.3.2.3.2.13.3.1.7
Remote Type. notApplicable - when prtInLs6TandemMode=tandemSlave
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ls6(1), km2kSlave(2), km2kStandalone(3), notApplicable(255)  

prtInLs6LinkTo 1.3.6.1.4.1.164.3.2.3.2.13.3.1.8
It indicates the slot of the main link card to which the Ls6 card is mapped. In the ?004 Unit the entries io6(10)..io12(16) are not valid. notApplicable - when prtInLs6TandemMode=tandemSlave. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort.
Status: deprecated Access: read-write
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtExVc3CnfgTable 1.3.6.1.4.1.164.3.2.3.2.14.1
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExVc3CnfgEntry

prtExVc3CnfgEntry 1.3.6.1.4.1.164.3.2.3.2.14.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtExVc3CnfgEntry  

prtExVc3CnfgIdx 1.3.6.1.4.1.164.3.2.3.2.14.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

prtExVc3SltIdx 1.3.6.1.4.1.164.3.2.3.2.14.1.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExVc3PrtIdx 1.3.6.1.4.1.164.3.2.3.2.14.1.1.3
A unique identifier of the port, within the card.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3)  

prtExVc3Connect 1.3.6.1.4.1.164.3.2.3.2.14.1.1.4
This attribute indicates whether the port should be considered in any of the mux algorithms.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtExVc3TransGain 1.3.6.1.4.1.164.3.2.3.2.14.1.1.5
Transmit gain in dBm.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtExVc3ReceiveGain 1.3.6.1.4.1.164.3.2.3.2.14.1.1.6
Receive gain in dBm.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtExVc3Wire 1.3.6.1.4.1.164.3.2.3.2.14.1.1.7
This object is equal for all the ports in the specific card because of HW limitations
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER w2wire(1), w4wire(2)  

prtExVc3Rate 1.3.6.1.4.1.164.3.2.3.2.14.1.1.8
Rate in bps.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER r9600bps(1), r4800bps(2)  

prtExVc3EchoCanceler 1.3.6.1.4.1.164.3.2.3.2.14.1.1.9
Echo canceler activation. The value will be the same for all the card's external ports.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtInVc3CnfgTable 1.3.6.1.4.1.164.3.2.3.2.14.2
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtInVc3CnfgEntry

prtInVc3CnfgEntry 1.3.6.1.4.1.164.3.2.3.2.14.2.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtInVc3CnfgEntry  

prtInVc3CnfgIdx 1.3.6.1.4.1.164.3.2.3.2.14.2.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

prtInVc3SltIdx 1.3.6.1.4.1.164.3.2.3.2.14.2.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtInVc3PrtIdx 1.3.6.1.4.1.164.3.2.3.2.14.2.1.3
A unique identifier of the port, within the card.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER inPrt1(101)  

prtInVc3Connect 1.3.6.1.4.1.164.3.2.3.2.14.2.1.4
This attribute indicates whether the port should be considered in any of the mux algorithms.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtInVc3Rate 1.3.6.1.4.1.164.3.2.3.2.14.2.1.5
Rate in bps.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER r32000bps(1), r16000bps(2)  

prtInVc3Oos 1.3.6.1.4.1.164.3.2.3.2.14.2.1.6
This object is equal for all the ports in the specific card because of HW limitations
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER forcedIdle(1), forcedBusy(2), busyIdle(3), idleBusy(4)  

prtInVc3LinkTo 1.3.6.1.4.1.164.3.2.3.2.14.2.1.7
This attribute indicates the slot of the ML card to which the VC card is mapped. In the ?004 Unit the entries io6(10)..io12(16) are not valid. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort.
Status: deprecated Access: read-write
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExVcPbxCnfgTable 1.3.6.1.4.1.164.3.2.3.2.15.1
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExVcPbxCnfgEntry

prtExVcPbxCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.15.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtExVcPbxCnfgEntry  

prtExVcPbxCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.15.1.1.1
This object indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

prtExVcPbxSltIdx 1.3.6.1.4.1.164.3.2.3.2.15.1.1.2
This object indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExVcPbxPrtIdx 1.3.6.1.4.1.164.3.2.3.2.15.1.1.3
A unique identifier of the port, within the card.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER exPrt1(1)  

prtExVcPbxConnect 1.3.6.1.4.1.164.3.2.3.2.15.1.1.4
This object indicates whether the port should be considered in any of the mux algorithms.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtExVcPbxGroup 1.3.6.1.4.1.164.3.2.3.2.15.1.1.5
The group object links together several VC-PBX cards, concerning compression of the same input T1/E1 link time-slots. When ports of different slots have the same group, they are linked. When ports have a different group, they are not linked. For VC-PBX/T1 and E1 cards, this object is - their own IO Slot. In the ?004 Unit the entries io6(10)..io12(16) are not valid.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtExVcPbxTransparent 1.3.6.1.4.1.164.3.2.3.2.15.1.1.6
This object indicates whether the Transparent transfer of Time-Slots is required or not. Time-Slots transferred by Transparent, will not be compressed. no - applicable only for VC-PBX/T1 and VC-PBX/E1 cards yes - applicable only for VC-PBX/T1 and VC-PBX/E1 cards notApplicable - only for VC-PBX cards.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3), notApplicable(255)  

prtExVcPbxTransSignalTs 1.3.6.1.4.1.164.3.2.3.2.15.1.1.7
This object specifies the ML Time-Slot dedicated to the signaling of the PABX Transparent TSs. None = 255. When prtExVcPbxTransparent=no this object's value=None (255) When prtExVcPbxTransparent=notApplicable, this object's value=None (255). When prtExVcPbxTransparent=yes: - for VC-PBX/T1 ports, this object's valid values are 1..16 or None (255). - for VC-PBX/E1 ports, this object's value will be 16 or None (255).
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtExVcPbxFrame 1.3.6.1.4.1.164.3.2.3.2.15.1.1.8
This object is the frame parameter for T1/E1 interface. The user should select only the parameters which are relevant to the specific card: T1 values for the VC-PBX/T1 card. E1 values for the VC-PBX/E1 card. notApplicable - for the VC-PBX card. This parameter has the same values as dsx1LineType in T1/E1 MIB (RFC-1406). The parameters in dsx1LineType are: other (1) esfT1 dsx1ESF (2) sfT1 dsx1D4 (3) g732nE1 dsx1E1 (4) g732nE1CRC dsx1E1-CRC (5) g732sE1 dsx1E1-MF (6) g732sE1CRC dsx1E1-MF-CRC (7)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER esfT1(2), sfT1(3), g732nE1(4), g732nE1CRC(5), g732sE1(6), g732sE1CRC(7), notApplicable(255)  

prtExVcPbxRestoreTime 1.3.6.1.4.1.164.3.2.3.2.15.1.1.9
The time passing from the disappearance of the loss of synchronization condition (red alarm) to the restoration of normal service. The options 1secFast(2) and 10sec62411(3) for E1 interfaces are proprietary implementation of the T1 standard to the E1 interface. ccittE1 - is applicable only for VC-PBX/E1 card notApplicable - is applicable for VC-PBX card
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER restoreT1secFast(2), restoreT10sec62411(3), ccittE1(4), notApplicable(255)  

prtExVcPbxLineCode 1.3.6.1.4.1.164.3.2.3.2.15.1.1.10
This object is the line code parameter used for T1/E1 interface. The user should select only the parameters which are relevant to the specific card: T1 line code parameters for VC-PBX/T1 E1 line code parameters for VC-PBX/E1 notApplicable - for VC-PBX This parameter has the same values as dsx1LineCoding in T1/E1 MIB (RFC-1406). The parameters in dsx1LineCoding are: dsx1JBZS (1) dsx1B8ZS (2) dsx1HDB3 (3) dsx1ZBTSI (4) dsx1AMI (5) other (6)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER b7zsT1(1), b8zsT1(2), transT1(3), hdb3E1(4), notApplicable(255)  

prtExVcPbxLineLength 1.3.6.1.4.1.164.3.2.3.2.15.1.1.11
This object is the line length parameter. It is applicable only for the VC-PBX/T1 card. notApplicable - for the VC-PBX and VC-PBX/E1 card. lenXXXpXXXft = len-XXX-XXXft.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), len0p133ft(2), len134p266ft(3), len267p399ft(4), len400p533ft(5), len534p655ft(6), notApplicable(255)  

prtExVcPbxLinkTo 1.3.6.1.4.1.164.3.2.3.2.15.1.1.12
This object indicates the slot of the ML card to which the VC-PBX/T1, VC-PBX/E1 card Transparent TSs are mapped. notApplicable - for VC-PBX card AND for VC-PBX/T1, VC-PBX/E1 cards, when prtExVcPbxTransparent=no . In the ?004 Unit the entries io6(10)..io12(16) are not valid. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort.
Status: deprecated Access: read-write
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtExVcPbxSignalOper 1.3.6.1.4.1.164.3.2.3.2.15.1.1.13
This object indicates the Signaling Operation of the VC-PBX/T1, VC-PBX/E1 external port. notApplicable - for VC-PBX card normal - all 4 signaling bits are transferred. bEqA - copy the A bit into the B bit. Applicable only for VC-PBX/T1.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), normal(2), bEqA(3), inverseA(4)  

prtExVcPbxIdleCode 1.3.6.1.4.1.164.3.2.3.2.15.1.1.14
Determines the code for transmission in empty time slots. notApplicable - for VC-PBX card .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), hff(2), he4(3), hd5(4), h9e(5), h98(6), h7f(7), h7e(8), h54(9), h1a(10)  

prtIn1p6VcPbxCnfgTable 1.3.6.1.4.1.164.3.2.3.2.15.2
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtIn1p6VcPbxCnfgEntry

prtIn1p6VcPbxCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.15.2.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtIn1p6VcPbxCnfgEntry  

prtIn1p6VcPbxCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.15.2.1.1
This object indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

prtIn1p6VcPbxSltIdx 1.3.6.1.4.1.164.3.2.3.2.15.2.1.2
This object indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtIn1p6VcPbxPrtIdx 1.3.6.1.4.1.164.3.2.3.2.15.2.1.3
A unique identifier of the port, within the card.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER inPrt1(101), inPrt2(102), inPrt3(103), inPrt4(104), inPrt5(105), inPrt6(106)  

prtIn1p6VcPbxConnect 1.3.6.1.4.1.164.3.2.3.2.15.2.1.4
This object indicates whether the port should be considered in any of the mux algorithms.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtIn1p6VcPbxRate 1.3.6.1.4.1.164.3.2.3.2.15.2.1.5
This object indicates the port Rate. For Normal mode (prtIn7p8VcPbxMode=normal), only part of the values are valid (constant rate). For Server mode (prtIn7p8VcPbxMode=server), all values are applicable (user can select the desired compression rate).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER r4800bps(1), r6400bps(2), r7200bps(3), r8000bps(4), r9600bps(5), r12800bps(6)  

prtIn1p6VcPbxEchoCanceler 1.3.6.1.4.1.164.3.2.3.2.15.2.1.6
Echo canceler activation.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtIn1p6VcPbxPabxTs 1.3.6.1.4.1.164.3.2.3.2.15.2.1.7
This object defines the PABX Time-Slot assigned to this internal port. For a T1 link, the valid values are: 1 .. 24. For an E1 link, the valid values are: 1 .. 31. This object is NOT applicable when prtIn1p6VcPbxConnect=no. This object is applicable for all cards of VC-PBX family. Default=the internal port index (1..6).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..31  

prtIn7p8VcPbxCnfgTable 1.3.6.1.4.1.164.3.2.3.2.15.3
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtIn7p8VcPbxCnfgEntry

prtIn7p8VcPbxCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.15.3.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtIn7p8VcPbxCnfgEntry  

prtIn7p8VcPbxCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.15.3.1.1
This object indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

prtIn7p8VcPbxSltIdx 1.3.6.1.4.1.164.3.2.3.2.15.3.1.2
This object indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtIn7p8VcPbxPrtIdx 1.3.6.1.4.1.164.3.2.3.2.15.3.1.3
A unique identifier of the port, within the card.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER inPrt7(107), inPrt8(108)  

prtIn7p8VcPbxConnect 1.3.6.1.4.1.164.3.2.3.2.15.3.1.4
This object indicates whether the port should be considered in any of the mux algorithms.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtIn7p8VcPbxMode 1.3.6.1.4.1.164.3.2.3.2.15.3.1.5
This object indicates the working mode of the port: - normal - the compressed voice will be sent to an MTML card inside the Mux. - server - the compressed voice will be sent to the Digital Voice connector, as a service to an outside user.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER normal(1), server(2)  

prtIn7p8VcPbxRate 1.3.6.1.4.1.164.3.2.3.2.15.3.1.6
This object indicates the port Main Rate. For Server mode (prtIn7p8VcPbxMode=server), the value will be notApplicable.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER r32Kbps(1), r16Kbps(2), notApplicable(255)  

prtIn7p8VcPbxSignalMode 1.3.6.1.4.1.164.3.2.3.2.15.3.1.7
This object indicates the Signal Mode. For Server mode (prtIn7p8VcPbxMode=server), the only valid values are: - none - aBit
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), aBit(2), abcBit(3), abcdBit(4)  

prtIn7p8VcPbxOos 1.3.6.1.4.1.164.3.2.3.2.15.3.1.8
Out of service Signaling mode.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER forcedIdle(1), forcedBusy(2)  

prtIn7p8VcPbxLinkTo 1.3.6.1.4.1.164.3.2.3.2.15.3.1.9
This object indicates the slot of the ML card to which the VC card is mapped. In the ?004 Unit the entries io6(10)..io12(16) are not valid. For Server mode (prtIn7p8VcPbxMode=server), this object is not applicable. Both ports, 7 and 8 should be linked to the same Slot. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort.
Status: deprecated Access: read-write
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtExVcPbxTsTable 1.3.6.1.4.1.164.3.2.3.2.15.4
The write operation into the table objects is valid only to the TmpCnfg entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtExVcPbxTsEntry

prtExVcPbxTsEntry 1.3.6.1.4.1.164.3.2.3.2.15.4.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtExVcPbxTsEntry  

prtExVcPbxTsCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.15.4.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

prtExVcPbxTsSltIdx 1.3.6.1.4.1.164.3.2.3.2.15.4.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExVcPbxTsPrtIdx 1.3.6.1.4.1.164.3.2.3.2.15.4.1.3
This attribute indicates a unique port number. VCPBX/E1, VCPBX/T1, VFPBX/E1, VFPBX/T1, VF-24/T1 and VF-30 cards have only one external interface. VF-48/T1 and VF-60/E1 cards have two external interfaces. VFS cards have also internal ports.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), inPrt9(109), inPrt10(110)  

prtExVcPbxTsIdx 1.3.6.1.4.1.164.3.2.3.2.15.4.1.4
This attribute indicates a unique PABX time slot position. The valid time slots are 1..24 for T1 cards and 1..31 for E1 cards.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtExVcPbxTsMode 1.3.6.1.4.1.164.3.2.3.2.15.4.1.5
This attribute indicates the usage, process and way of the specific PABX TS towards its destination: unused - the TS is not used (no processing, no destination). compressed - the TS is used, sent for compression to an internal port (for VF-PBX cards: 1..6 for of either the same card or a VF-PBX card of the same group). For VF-24/30/48/60 - 'compressed' represents 'compressed Voice' (to differentiate it from 'compressedCcs'). In this case, the TS is compressed by an internal port (1..8). transparent - the TS is used; no processing. It is sent directly for Bypass to a ML card the VF port/TS is linked to. compressedCcs - supported only by VF-24/30/48/60 cards. The TS is used; sent for compression to the CPU. mng - the TS is used for Management (this option is used when the external port is connected to another product that has to be managed via this dedicated TS. ccs1..ccs8 - supported only by VF-24/30/48/60 cards. Compressed TS that comes from a bundle of V5.1 or V5.2 PBX. ss7n1..ss7n8 - supported only by VF-24/30/48/60 cards. Compressed TS that comes from a bundle of V5.1 or V5.2 PBX. ss7n1 can work versus Vmux having prtExPh1MlTsType=ss7(6).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unused(1), compressed(2), transparent(3), compressedCcs(4), mng(5), ccs1(11), ccs2(12), ccs3(13), ccs4(14), ccs5(15), ccs6(16), ccs7(17), ccs8(18), ss7n1(41), ss7n2(42), ss7n3(43), ss7n4(44), ss7n5(45), ss7n6(46), ss7n7(47), ss7n8(48)  

prtExVcPbxTsIConSlot 1.3.6.1.4.1.164.3.2.3.2.15.4.1.6
For VF-PBX cards, the io1..io12 values are applicable only when prtExVcPbxTsMode=compressed. Otherwise, its value should be noConnect. For VF-24/30/48/60 cards: - when prtExVcPbxTsMode=transparent or voiceTransparent, the io1..io12 values are applicable, indicating the ML Slot this TS is connected to. - when prtExVcPbxTsMode=compressed or compressedCcs, the value will be the same as prtExVcPbxTsSltIdx, since the compression is done within the same card. - for rest of the prtExVcPbxTsMode values, the value will be: noConnect. This object indicates whether the specified compressed/transparent time slot is connected/routed internally in the Agent and to which card it is connected. For VF-PBX card, the valid selectable slots are either the current one, (prtExVcPbxTsSltIdx), or a slot containing a VF-PBX card. In the ?004 Unit the entries io6(10)..io12(16) are not valid.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noConnect(2), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExVcPbxTsIConPrt 1.3.6.1.4.1.164.3.2.3.2.15.4.1.7
This attribute indicates the port to which this TS is connected. For VF-PBX cards, only inPrt1..inPrt6 ports are valid. For VF-24/30/48/60 cards: - for prtExVcPbxTsMode=transparent or voiceTransparent, the valid ports are ML ports (exPrt1.. exPrt8, inPrt1.. inPrt8) - for prtExVcPbxTsMode=compressed or compressedCcs, the valid ports are internal ports of the same card (inPrt1..inPrt8) noConnect - when prtExVcPbxTsIConSlot=noConnect.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6), exPrt7(7), exPrt8(8), noConnect(100), inPrt1(101), inPrt2(102), inPrt3(103), inPrt4(104), inPrt5(105), inPrt6(106), inPrt7(107), inPrt8(108)  

prtExVcPbxTsIConTs 1.3.6.1.4.1.164.3.2.3.2.15.4.1.8
This attribute indicates the ML TS to which this TS is connected. This object is not applicable for VF-PBX cards. For VF-24/30/48/60 cards it is applicable only when prtExVcPbxTsMode=transparent or voiceTransparent. The valid time slots are 1..24 for ML T1 cards and 1..31 for ML E1 cards. notApplicable - 255.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..255  

prtExVcPbxTsRemPrt 1.3.6.1.4.1.164.3.2.3.2.15.4.1.9
This attribute indicates the end-point port on the Remote unit. VF-24/T1 and VF-30/E1 cards have one external interface. VF-48/T1 and VF-60/E1 cards have two external interfaces. noConnect - when prtExVcPbxTsMode=unused, transparent, voiceTransparent or mng.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), noConnect(100)  

prtExVcPbxTsRemTs 1.3.6.1.4.1.164.3.2.3.2.15.4.1.10
This attribute indicates the end-point TS on the Remote unit. The valid time slots are 1..24 for T1 ports and 1..31 for E1 ports. notApplicable - 255.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtExVcPbxTsRemConnID 1.3.6.1.4.1.164.3.2.3.2.15.4.1.11
This attribute indicates the Connection ID with the Remote unit. notApplicable = 0.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

prtExVcPbxTsSourceSlot 1.3.6.1.4.1.164.3.2.3.2.15.4.1.12
For VFS cards. These cards offer Compresed Voice Services for Analog Voice ports of the MP. This object indicates the Source Slot of the Analog Voice port we want to compress. io1..io12 values are applicable only when prtExVcPbxTsMode=compressed(voice). Otherwise, its value should be noConnect. In the ?004 Unit the entries io6(10)..io12(16) are not valid.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noConnect(2), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtExVcPbxTsSourcePrt 1.3.6.1.4.1.164.3.2.3.2.15.4.1.13
For VFS cards. These cards offer Compresed Voice Services for Analog Voice ports of the MP. This object indicates the Source Port within the Slot of the Analog Voice Card, we want to compress. exPrt1 - exPrt16 = 1 - 16 noConnect=100 - when prtExVcPbxTsCvServiceSlot=noConnect.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

prtIsdnCnfgTable 1.3.6.1.4.1.164.3.2.3.2.16.1
The write operation into the table objects is valid only to the TmpCnfg entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtIsdnCnfgEntry

prtIsdnCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.16.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtIsdnCnfgEntry  

prtIsdnCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.16.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

prtIsdnSltIdx 1.3.6.1.4.1.164.3.2.3.2.16.1.1.2
This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid For KM2100/4 Valid entries are 'kmxMlA ' or 'kmxMlB'
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), kmxMlA(103), kmxMlB(104), notApplicable(255)  

prtIsdnPrtIdx 1.3.6.1.4.1.164.3.2.3.2.16.1.1.3
This attribute indicates a unique port number. For MAXcess the values will be: exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), For KM-2100 the port index is calculated as follows: 100*Slot+Ch
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtIsdnConnect 1.3.6.1.4.1.164.3.2.3.2.16.1.1.4
This attribute indicates if the port is connected.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtIsdnSignalingProtocol 1.3.6.1.4.1.164.3.2.3.2.16.1.1.5
This attribute fixes which signaling protocol is used at this port (D-Channel). It is equivalent to isdnSignalingProtocol in the isdn MIB.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER other(1), etsi(3), ess4(5), ess5(6), dms100(7), ni1(9), ni2(10), ins64(17), ins1500(18), qsig(21), notApplicable(255)  

prtIsdnBasicRateLineTopology 1.3.6.1.4.1.164.3.2.3.2.16.1.1.6
This attribute is relevant for ISDN BRI only. It is equivalent to isdnBasicRateLineTopology in the isdn MIB.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER pointToPoint(1), pointToMultipoint(2), notApplicable(255)  

prtIsdnMode 1.3.6.1.4.1.164.3.2.3.2.16.1.1.7
This attribute allows the user to configure the port as leased(2) in case of connection to a TDM network.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER dialup(1), leased(2), syncLeased(3), notApplicable(255)  

prtIsdnFilter 1.3.6.1.4.1.164.3.2.3.2.16.1.1.8
This attribute allows the user to configure the port: answerAll(2): accept all incoming calls, rejectAll(3): reject all incoming calls, selective(4): accept or reject according directory table. callBack (5): In this mode the ISDN Ch will reject incoming calls and will initiate call back to the rejected phone number.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), answerAll(2), rejectAll(3), selective(4), callBack(5)  

prtIsdnSimultaneousCall 1.3.6.1.4.1.164.3.2.3.2.16.1.1.9
In case of simultaneous call (local,remote and remote,local): accept(2): accept the incoming call, reject(3): reject the incoming call.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), accept(2), reject(3)  

prtIsdnNumOfAbstractTerm 1.3.6.1.4.1.164.3.2.3.2.16.1.1.10
An object for KM2100/4 agents. 255=Not Applicable When ISDN Standard = ETSI or NTT (European) the value should be 255 (NotApplicable) else If ML speed is 64Kbps value should be 1. If ML speed is 128Kbps value can be either 1 or 2 (user selection).
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtIsdnSwitchMode 1.3.6.1.4.1.164.3.2.3.2.16.1.1.11
For KM2100. auto - The call is initiated automatically by one of the IO cards connected to KML.10(ISDN card) having ISDN Switch Mode. manual - The call is initiated by the user manually, for KML.10 having ISDN Switch Mode (via mdlSCmd). connect- The call is initiated 'immediately', for KML.10 having ISDN Switch Mode. 'immediately'- means: immediately after power-up (when product performed Reset) OR, since this value appears in the active configuration. In this case, the call can be disconnected only by power-off of the product or by changing this object to another value (or actual Remove of the KML.10 relevant card). notApplicable - For other card types.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), auto(2), manual(3), connect(4)  

prtIsdnAbSide 1.3.6.1.4.1.164.3.2.3.2.16.1.1.12
This parameter indicates the QSIG side in layer 3. This definition is from the QSIG Standard.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), aSide(2), bSide(3)  

prtIsdnQsigRole 1.3.6.1.4.1.164.3.2.3.2.16.1.1.13
This parameter indicates the QSIG side in layer 1 & 2.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), slave(2), master(3)  

prtIsdnInterface 1.3.6.1.4.1.164.3.2.3.2.16.1.1.14
It indicates the interface type: lt = line termination nt = network termination te = terminal equipment.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER lt(1), nt(2), te(3), notApplicable(255)  

prtIsdnCallMode 1.3.6.1.4.1.164.3.2.3.2.16.1.1.15
This object indicates the acceptance of incoming calls. Initiate - Callout Listen - Callin.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), initiate(2), listen(3)  

prtIsdnCallBackTimeout 1.3.6.1.4.1.164.3.2.3.2.16.1.1.16
This object is applicable only if 'prtIsdnFilter' is 'CallBack' and determines how long to wait from receiving the incoming call until initiating the call back call. The vaules range should be '1..20 sec' and the default 10 sec.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtIsdnEndpointTable 1.3.6.1.4.1.164.3.2.3.2.16.2
The write operation into the table objects is valid only to the TmpCnfg entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtIsdnEndpointEntry

prtIsdnEndpointEntry 1.3.6.1.4.1.164.3.2.3.2.16.2.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtIsdnEndpointEntry  

prtIsdnEndpointCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.16.2.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

prtIsdnEndpointSltIdx 1.3.6.1.4.1.164.3.2.3.2.16.2.1.2
This attribute indicates a unique slot position where the card is inserted. In ?004 Unit the entries io6(10)..io12(16) are not valid For KM2100/4 Valid entries are 'kmxMlA ' or 'kmxMlB'
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), kmxMlA(103), kmxMlB(104), notApplicable(255)  

prtIsdnEndpointPrtIdx 1.3.6.1.4.1.164.3.2.3.2.16.2.1.3
This attribute indicates a unique port number. For MAXcess the values will be: exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), For KM-2100 the port index is calculated as follows: 100*Slot+Ch
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtIsdnEndpointIdx 1.3.6.1.4.1.164.3.2.3.2.16.2.1.4
Since more than one endpoint may be defined per isdn entity, this field is a simple index. It corresponds to isdnEndpointIdx in the isdn MIB.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER atei1(1), atei2(2)  

prtIsdnEndpointTeiType 1.3.6.1.4.1.164.3.2.3.2.16.2.1.5
The type of TEI (Terminal Endpoint Identifier) used for this Terminal Endpoint. In case of dynamic(1), the TEI value is selected by the switch. In case of static(2), a valid TEI value has to be entered in the isdnEndpointTeiValue object. interface type as well as the Terminal Endpoint type. static(2). On Basic Rate interfaces the default value is dynamic(1) for isdn(63) Terminal Endpoints. It corresponds to isdnEndpointTeiType in the isdn MIB.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER dynamic(1), static(2), notApplicable(255)  

prtIsdnEndpointTeiValue 1.3.6.1.4.1.164.3.2.3.2.16.2.1.6
When the TEI Type is static, the value of the TEI should be between 0 and 63. Else, it is not selectable by user. 255 = notApplicable. It corresponds to isdnEndpointTeiValue in the isdn MIB
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

prtIsdnEndpointSpid 1.3.6.1.4.1.164.3.2.3.2.16.2.1.7
The Service profile IDentifier (SPID) information for this Terminal Endpoint. It is is composed of 9-20 numeric characters. It corresponds to isdnEndpointSpid in the isdn MIB.
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString  

prtIsdnEndpointBearerCh 1.3.6.1.4.1.164.3.2.3.2.16.2.1.8
This is the selected dialing channel. anyChannel - the system selects the dialing channel.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER notApplicable(1), anyChannel(2), channelB1(3), channelB2(4)  

prtIsdnEndpointRowStatus 1.3.6.1.4.1.164.3.2.3.2.16.2.1.9
This field indicates whether to consider this endpoint or not. The only possible supported RowStatus vaules are active (1) and destroy (6).
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

prtIsdnDirectoryTable 1.3.6.1.4.1.164.3.2.3.2.16.3
The write operation into the table objects is valid only to the TmpCnfg entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtIsdnDirectoryEntry

prtIsdnDirectoryEntry 1.3.6.1.4.1.164.3.2.3.2.16.3.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtIsdnDirectoryEntry  

prtIsdnDirectoryCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.16.3.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

prtIsdnDirectorySltIdx 1.3.6.1.4.1.164.3.2.3.2.16.3.1.2
This attribute indicates a unique slot position where the card is inserted. For MX300/30 ports: io1(5) = isdn1(5) and io2(6) = isdn2(6). In ?004 Unit the entries io6(10)..io12(16) are not valid For KM2100/4 Valid entries are 'kmxMlA ' or 'kmxMlB'
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), kmxMlA(103), kmxMlB(104), notApplicable(255)  

prtIsdnDirectoryPrtIdx 1.3.6.1.4.1.164.3.2.3.2.16.3.1.3
For MAXcess this is the internal port number: 101, 102,.... For KM-2100 the port index is calculated as follows: 100*Slot+Ch
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtIsdnDirectoryLocalAddr 1.3.6.1.4.1.164.3.2.3.2.16.3.1.4
This is the local address associated with this entry. - For MX: Size=17 , Default=0 (17 characters) - For KM: Size=20, Default=blank (20 characters)
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(17..20)  

prtIsdnDirectoryLocalSubAddr 1.3.6.1.4.1.164.3.2.3.2.16.3.1.5
This is the local subaddress associated with this entry. - For MX: Size=6 , Default=0 (6 characters) - For KM: Size=4 , Default=blank (4 characters)
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(4..6)  

prtIsdnDirectoryRemoteAddr 1.3.6.1.4.1.164.3.2.3.2.16.3.1.6
This is the remote address associated with this entry. - For MX: Size=17 , Default=0 (17 characters) - For KM: Size=20, Default=blank (20 characters)
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(17..20)  

prtIsdnDirectoryRemoteSubAddr 1.3.6.1.4.1.164.3.2.3.2.16.3.1.7
This is the remote subaddress associated with this entry. - For MX: Size=6 , Default=0 (6 characters) - For KM: Size=4 , Default=blank (4 characters)
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(4..6)  

prtIsdnDirectoryPrtNu 1.3.6.1.4.1.164.3.2.3.2.16.3.1.8
This is the external port number connected to this entry.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

prtIsdnDirectoryTeiId 1.3.6.1.4.1.164.3.2.3.2.16.3.1.9
This is the abstract terminal id if relevant, connected to this entry.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

prtIsdnDirectoryRowStatus 1.3.6.1.4.1.164.3.2.3.2.16.3.1.10
This is the status for the row. It allows to know whether to consider this row or not. The only possible supported RowStatus vaules are active (1) and destroy (6).
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

prtIsdnDirectoryLocalAddr2 1.3.6.1.4.1.164.3.2.3.2.16.3.1.11
This is the second local address associated with this entry. - For MX: Size=17 , Default=0 (17 characters) - For KM: Size=20, Default=blank (20 characters)
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(17..20)  

prtIsdnDirectoryLocalSubAddr2 1.3.6.1.4.1.164.3.2.3.2.16.3.1.12
This is the second local subaddress associated with this entry. - For MX: Size=6 , Default=0 (6 characters) - For KM: Size=4 , Default=blank (4 characters)
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(4..6)  

prtIsdnDirectoryRemoteAddr2 1.3.6.1.4.1.164.3.2.3.2.16.3.1.13
This is the second remote address associated with this entry. - For MX: Size=17 , Default=0 (17 characters) - For KM: Size=20, Default=blank(20 characters)
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(17..20)  

prtIsdnDirectoryRemoteSubAddr2 1.3.6.1.4.1.164.3.2.3.2.16.3.1.14
This is the second remote subaddress associated with this entry. - For MX: Size=6 , Default=0 (6 characters) - For KM: Size=4 , Default=blank (4 characters)
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(4..6)  

prtFrPlusCnfgTable 1.3.6.1.4.1.164.3.2.3.2.18.1
The write operation into the Table Objects is valid only to the TmpCnfg entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtFrPlusCnfgEntry

prtFrPlusCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.18.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtFrPlusCnfgEntry  

prtFrPlusCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.18.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

prtFrPlusSltIdx 1.3.6.1.4.1.164.3.2.3.2.18.1.1.2
Slot Index. For ISDN BRI Ports of MX300/30, io1(5) = isdn1(5) and io2(6) = isdn2(6).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtFrPlusPrtIdx 1.3.6.1.4.1.164.3.2.3.2.18.1.1.3
This attribute indicates a unique port number. This port number should be: - for ISDN cards: inPrt1(101)->inPrt50(150) - for MHS1 card : exPrt1(1) - for MHS3, MLS3 cards: exPrt1(1)->exPrt3(3) - for MLS6 cards: exPrt1(1)->exPrt6(6).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtFrPlusNotSegmentedPriorities 1.3.6.1.4.1.164.3.2.3.2.18.1.1.4
This parameter is relevant only for FR+ protocol and asks the MXcess NOT to segment data with specified priorities: from LSB: bit 1 is for priority 1, bit 2 is for priority 2, .... till bit 7 for priority 7. - a priority selected to be segmented : its bit will be '0' - a priority not to be segmented : its bit will be '1' Default is 00000000; i.e, segment all priorities.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1)  

prtMl4CnfgTable 1.3.6.1.4.1.164.3.2.3.2.19.1
This is an extension table for MTML-4 card parameters.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtMl4CnfgEntry

prtMl4CnfgEntry 1.3.6.1.4.1.164.3.2.3.2.19.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtMl4CnfgEntry  

prtMl4CnfgIdx 1.3.6.1.4.1.164.3.2.3.2.19.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. The write operation is valid only to the TmpCnfg.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

prtMl4SltIdx 1.3.6.1.4.1.164.3.2.3.2.19.1.1.2
This attribute indicates a unique slot position where the module is inserted.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER clA(3), clB(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtMl4PrtIdx 1.3.6.1.4.1.164.3.2.3.2.19.1.1.3
This attribute indicates a unique port number.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6), exPrt7(7), exPrt8(8), inPrt1(101), inPrt2(102), inPrt3(103), inPrt4(104), inPrt5(105), inPrt6(106), inPrt7(107), inPrt8(108), inPrt9(109), inPrt10(110), inPrt11(111), inPrt12(112), inPrt13(113), inPrt14(114), inPrt15(115), inPrt16(116), inPrt17(117), inPrt18(118), inPrt19(119), inPrt20(120), inPrt21(121), inPrt22(122), inPrt23(123), inPrt24(124), inPrt25(125), inPrt26(126), inPrt27(127), inPrt28(128), inPrt29(129), inPrt30(130), inPrt31(131), inPrt32(132), inPrt33(133), inPrt34(134), inPrt35(135), inPrt36(136), inPrt37(137), inPrt38(138), inPrt39(139), inPrt40(140), inPrt41(141), inPrt42(142), inPrt43(143), inPrt44(144), inPrt45(145), inPrt46(146), inPrt47(147), inPrt48(148), inPrt49(149), inPrt50(150), inPrt51(151), inPrt52(152), inPrt53(153), inPrt54(154), inPrt55(155), inPrt56(156), inPrt57(157), inPrt58(158), inPrt59(159), inPrt60(160), inPrt61(161), inPrt62(162), inPrt63(163), inPrt64(164), inPrt65(165), inPrt66(166), inPrt67(167), inPrt68(168), inPrt69(169), inPrt70(170), inPrt71(171), inPrt72(172), inPrt73(173), inPrt74(174), inPrt75(175), inPrt76(176), inPrt77(177), inPrt78(178), inPrt79(179), inPrt80(180), inPrt81(181), inPrt82(182), inPrt83(183), inPrt84(184)  

prtMl4SigProfile 1.3.6.1.4.1.164.3.2.3.2.19.1.1.4
This object indicates the Signaling Profile of the port. none - when the Frame is G732N (no MF) or Unframed. p1 = profile 1 p2 = profile 2 p3 = profile 3 p4 = profile 4 p5 = profile 5 perTS = when Signaling Profile is selected per TS.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), none(2), p1(3), p2(4), p3(5), p4(6), p5(7), perTS(8)  

prtMl4CGA 1.3.6.1.4.1.164.3.2.3.2.19.1.1.5
This object selects the method used to signal the CGA state to the other end, through the main link. 'none' - non-transparent mode. When one of the links (main) will be in Out Of Service state, both 'Data/Voice Oos' and 'Oos' will be transmitted to the other end. 'trans' - when one of the links (main) will be in Out Of Service state, 'Data/Voice Oos' will be transmitted to the other end. 'full' - fully-transparent mode. When one of the links (main) will be in Out Of Service state, neither 'Data/Voice Oos' nor 'Oos' will be transmitted to the other end.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), trans(2), full(3)  

prtMl4Oos 1.3.6.1.4.1.164.3.2.3.2.19.1.1.6
'idle' = '0' = on-hook, idle state 'busy' = '1' = off-hook, busy state 'forcedIdle' = SP = both A and B signaling bits are forced to '0' during out-of-service periods. 'forcedBusy' = MK = both A and B signaling bits are forced to '1' during out-of-service periods. 'busyIdle' = MK_SP = A and B bits are forced to '1' for 2.5 seconds; then they are switched to '0' until out-of-service condition disappears. 'idleBusy' = SP_MK = A and B bits are forced to '0' for 2.5 seconds; then they are switched to '1' until out-of-service condition disappears. - for T1: '0'=0 ; '1'=1 - for E1: '0'=1 ; '1'=0
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notSupported(2), forcedIdle(3), forcedBusy(4), busyIdle(5), idleBusy(6)  

prtMl4VoiceOos 1.3.6.1.4.1.164.3.2.3.2.19.1.1.7
Voice Out-Of-Service code. Valid range: (0 - FF HEX). For agents that do not support this feature, the value will always be 0.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..4)  

prtMl4DataOos 1.3.6.1.4.1.164.3.2.3.2.19.1.1.8
Data Out-Of-Service code. Valid range: (0 - FF HEX). For agents that do not support this feature, the value will always be 0.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..4)  

prtMl4Service 1.3.6.1.4.1.164.3.2.3.2.19.1.1.9
Link Service. leasedLine - usual TDM interface. v51 - V5.1 interface. v52Master - V5.2 Link to Local Exchange. v52Slave - a ML that is transferred to the v52Master.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), leasedLine(2), v51(3), v52Master(4), v52Slave(5)  

prtMl4IpAddress 1.3.6.1.4.1.164.3.2.3.2.19.1.1.10
IP Address of the port.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

prtMl4IpMask 1.3.6.1.4.1.164.3.2.3.2.19.1.1.11
IP subnet mask of the port.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

prtMl4SignalingMode 1.3.6.1.4.1.164.3.2.3.2.19.1.1.12
Refers to the signaling mode of the port (or framer module). notApplicable(1)- means that no framer is needed for this port (no signaling), or that this object is not relevant. cas(2) means Channel Associated Signaling. Used for E1 Links. ccs(3) is the Common Channel Signaling (the signaling is not within the channels time slot - a TS for signaling is used). robbedBit(4) is a method implementing 7 bits for the voice and 1 bit dedicated for signaling. Used for T1 Links. other (5)- Signaling generally exists though not specifically according to one of the values listed ; this port uses a framer in this case.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), cas(2), ccs(3), robbedBit(4), other(5)  

prtMl4EchoCanceler 1.3.6.1.4.1.164.3.2.3.2.19.1.1.13
Echo canceler activation.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), off(2), on(3)  

prtMl4OosErrorSource 1.3.6.1.4.1.164.3.2.3.2.19.1.1.14
OOS (Out-of-Service) Error Source. This object is applicable for T1 ports only.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), none(2), framing(3), bpv(4)  

prtMl4OosEntryThreshold 1.3.6.1.4.1.164.3.2.3.2.19.1.1.15
This object defines the number of Errors per Second that determine the minimum unacceptable noise level. This value will be the Entry Threshold to the OOS (Out-of-Service) state. This object is applicable only when prtMl4OosErrorSource=framing(3) or bpv(4). 0=notApplicable.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..999  

prtMl4OosExitThreshold 1.3.6.1.4.1.164.3.2.3.2.19.1.1.16
This object defines the number of consecutive Error-Free-Seconds before going from OOS state to Normal state. This value will be the Exit Threshold from the OOS (Out-of-Service) state. Units=seconds This object is applicable only when prtMl4OosErrorSource=framing(3) or bpv(4). 0=notApplicable.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..99  

prtMl4LogicalLinkId 1.3.6.1.4.1.164.3.2.3.2.19.1.1.17
This object defines for a V5.2 Master ML the Logical Link Id. Valid values are: 0..256. NA=257.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..257  

prtMl4DedicatedTs 1.3.6.1.4.1.164.3.2.3.2.19.1.1.18
A unique number to identify Dedicated TS of the E1 port (V5.2). It is applicable only when prtMl4Service=v52Slave and prtExPh1MlInbandMng selected is dedicatedTs, dedicatedPpp or dedicatedFr. 1..31 - Dedicated TS of E1 255 - notApplicable Other values are invalid.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..255  

prtMl4RemCrc 1.3.6.1.4.1.164.3.2.3.2.19.1.1.19
This object indicates whether the E1 of the Remote device connected to this E1 port, will have CRC-4 or not.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

prtMl4CrossConnectLevel 1.3.6.1.4.1.164.3.2.3.2.19.1.1.20
This object indicates whether the cross connect is on DS1 or DS0 (time-slots) level. When cross connect level is ds1, Destination Slot is indicated by prtGenCnfgLinkToSlot, Destination Port is indicated by prtGenCnfgLinkToPort. For Unframed Line Type, cross connect level can be either notApplicable (NC=not connected) or DS1. Otherwise, default value is ds0.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), ds0(2), ds1(3)  

prtMl4PppEchoFailDetection 1.3.6.1.4.1.164.3.2.3.2.19.1.1.21
This object indicates whether the PPP Echo is taken into account for its Fail Detection. This object is relevant when Inband Mng between devices is Dedicated TS PPP. Default=Disable. Enable - will be selected mainly when a T1/E1 Ring exists and between 2 adjacent Ring devices there is another device or Net, that causes these Ring devices not to sense that the PPP connection between them is lost. In this case, Echo Request should be initiated by the port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

prtAcmCnfgTable 1.3.6.1.4.1.164.3.2.3.2.20.1
This is a table for ACM port parameters.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtAcmCnfgEntry

prtAcmCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.20.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtAcmCnfgEntry  

prtAcmCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.20.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. The write operation is valid only to the TmpCnfg.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

prtAcmSltIdx 1.3.6.1.4.1.164.3.2.3.2.20.1.1.2
This attribute indicates a unique slot position where the module is inserted.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255)  

prtAcmPrtIdx 1.3.6.1.4.1.164.3.2.3.2.20.1.1.3
This attribute indicates a unique port number.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), exPrt5(5), exPrt6(6), exPrt7(7), exPrt8(8), exPrt9(9), exPrt10(10), exPrt11(11), exPrt12(12)  

prtAcmConnect 1.3.6.1.4.1.164.3.2.3.2.20.1.1.4
This attribute indicates whether the port should be connected or not. Only a connected port can perform activity.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtAcmActiveState 1.3.6.1.4.1.164.3.2.3.2.20.1.1.5
This attribute indicates the Electric Active State of the port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER low(2), high(3)  

prtAcmAlrString 1.3.6.1.4.1.164.3.2.3.2.20.1.1.6
Alarm string selected by user for the Inbound ports. This object is applicable only for the Inbound Ports: ext-5..ext-12. For the Outbound Ports (ext-1..ext-4), the size of this string will be 0.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..35)  

prtE2CnfgTable 1.3.6.1.4.1.164.3.2.3.2.21.1
This is a table for E2 port parameters.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtE2CnfgEntry

prtE2CnfgEntry 1.3.6.1.4.1.164.3.2.3.2.21.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtE2CnfgEntry  

prtE2CnfgIdx 1.3.6.1.4.1.164.3.2.3.2.21.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. The write operation is valid only to the TmpCnfg.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

prtE2SltIdx 1.3.6.1.4.1.164.3.2.3.2.21.1.1.2
This attribute indicates a unique slot position where the module is inserted.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtE2PrtIdx 1.3.6.1.4.1.164.3.2.3.2.21.1.1.3
This attribute indicates a unique port number.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER exPrt1(1), exPrt2(2)  

prtE2Connect 1.3.6.1.4.1.164.3.2.3.2.21.1.1.4
This attribute indicates whether the port should be connected or not. Only a connected port can perform activity.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtE2MngOnNationalBit 1.3.6.1.4.1.164.3.2.3.2.21.1.1.5
This attribute indicates whether National Bit will be used for Management or not.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtLanWanCnfgTable 1.3.6.1.4.1.164.3.2.3.2.22.1
This is a table for Lan-Wan port parameters.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtLanWanCnfgEntry

prtLanWanCnfgEntry 1.3.6.1.4.1.164.3.2.3.2.22.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtLanWanCnfgEntry  

prtLanWanCnfgIdx 1.3.6.1.4.1.164.3.2.3.2.22.1.1.1
This object indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. The write operation is valid only to the TmpCnfg.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..255  

prtLanWanSltIdx 1.3.6.1.4.1.164.3.2.3.2.22.1.1.2
This object indicates a unique slot position where the module is inserted.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER notApplicable(1), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16)  

prtLanWanPrtIdx 1.3.6.1.4.1.164.3.2.3.2.22.1.1.3
This object indicates a unique number to identify a port in a specific card. Generally, for MP-210X/2200, the Port Index will be according to the external/internal port number: - exPrtX : X - inPrtX : 100 + X For FCD-155, refer to device specification
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

prtLanWanMode 1.3.6.1.4.1.164.3.2.3.2.22.1.1.4
This object determines the working mode of this port. For FCD155, layer3SubnetSwitch is not applicable
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), bridge(2), bridgeAndStp(3), layer3SubnetSwitch(4)  

prtLanWanDestIf 1.3.6.1.4.1.164.3.2.3.2.22.1.1.5
This object determines the Destination Interface for the frames received by this port. - Switching Table = 100 (it means that the destination interface will be determined by the Switching Table) - inPrtX (internal-X port): 100 + X . For FCD-155 this object is not applicable =0
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtLanWanEgressVlanMode 1.3.6.1.4.1.164.3.2.3.2.22.1.1.6
This object determines what to do with the VLAN frames that exit via the WAN side of the port. This object is not applicable when prtLanWanMode=l3SubnetSwitch(4).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), unmodified(2), tag(3), doubleTag(4), untag(5)  

prtLanWanL2Protocol 1.3.6.1.4.1.164.3.2.3.2.22.1.1.7
L2 Protocol. When prtLanWanMode=l3SubnetSwitch(4), the only valid value is ppp(3).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), none(2), ppp(3), hdlc(4), pppoHdlc(5), mlppp(6)  

prtLanWanStpPriority 1.3.6.1.4.1.164.3.2.3.2.22.1.1.8
The value of the priority field which is contained in the first (in network byte order) octet of the (2 octet long) Port ID.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..255  

prtLanWanStpCost 1.3.6.1.4.1.164.3.2.3.2.22.1.1.9
The contribution of this port to the path cost of paths towards the spanning tree root which include this port. 802.1D-1990 recommends that the default value of this parameter be in inverse proportion to the speed of the attached LAN.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..65535  

prtLanWanToLanVlanMode 1.3.6.1.4.1.164.3.2.3.2.22.1.1.10
This object determines what to do with the VLAN frames that come from WAN side of the port and exit towards one of the LAN ports. This object is applicable only when prtLanWanDestIf=100 or 101 (Switching Table or inPrt1).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), unmodified(2), tag(3), doubleTag(4), untag(5)  

prtLanWanVlanId 1.3.6.1.4.1.164.3.2.3.2.22.1.1.11
This is the VLAN Id attached to a frame, when the relevant Vlan Mode (prtLanWanEgressVlanMode or prtLanWanToLanVlanMode) is tag or doubleTag. 0=not applicable.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..4095  

prtLanWanVlanPriority 1.3.6.1.4.1.164.3.2.3.2.22.1.1.12
This is the VLAN Priority attached to a frame, when the relevant Vlan Mode (prtLanWanEgressVlanMode or prtLanWanToLanVlanMode) is tag or doubleTag. Valid values: 0..7 255=not applicable.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtLanWanMtu 1.3.6.1.4.1.164.3.2.3.2.22.1.1.13
The size of the largest packet which can be sent/received on the interface, specified in octets. Valid values change per device. 0=not applicable.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtLanWanVlanType 1.3.6.1.4.1.164.3.2.3.2.22.1.1.14
This oject indicates type of VLAN this port is assigned to. Port Base Vlan parameters are defined by objects under radBridgePortBaseVlan
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), portBasedVlan(2), ieee802dot1q(3), ieee802dot1qTaggedOnly(4)  

muxHubEvents 1.3.6.1.4.1.164.3.2.0
The events for .
Status: current Access: read-write
OBJECT-IDENTITY    

alarmsTrap 1.3.6.1.4.1.164.3.2.0.1
This trap is sent whenever alarm occurs in the agent.
Status: current Access: read-write
NOTIFICATION-TYPE    

sanityTrap 1.3.6.1.4.1.164.3.2.0.2
This trap is sent after a data base update. It returns the sanity result status and the configuration no. checked. If the result is of Flip DB Sanity Check, the configuration no. sent will be 0. If the result is of Variant Sanity Check, the configuration no. sent will be 100.
Status: current Access: read-write
NOTIFICATION-TYPE    

cnfgFlipTrap 1.3.6.1.4.1.164.3.2.0.3
This trap is sent upon change of the active Configuration DB. Attached, is the new active Configuration no.
Status: current Access: read-write
NOTIFICATION-TYPE    

flipDbChangeTrap 1.3.6.1.4.1.164.3.2.0.4
This trap is sent upon change of the active Flip tables (Flip DB).
Status: current Access: read-write
NOTIFICATION-TYPE    

statusChangedTrap 1.3.6.1.4.1.164.3.2.0.5
This trap is sent upon any change of the LEDs status.
Status: current Access: read-write
NOTIFICATION-TYPE    

ds1Interface 1.3.6.1.4.1.164.3.1.6.4
OBJECT IDENTIFIER    

prtDS1Events 1.3.6.1.4.1.164.3.1.6.4.0
OBJECT IDENTIFIER    

prtDs1PerfHistory 1.3.6.1.4.1.164.3.1.6.4.1
OBJECT IDENTIFIER    

dsx1XCurrentTable 1.3.6.1.4.1.164.3.1.6.4.1.2
A list of current statistics entries. This table contains additional objects for the current table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Dsx1XCurrentEntry

dsx1XCurrentEntry 1.3.6.1.4.1.164.3.1.6.4.1.2.1
An entry containing additional statistical counters applicable to a particular current table.
Status: current Access: not-accessible
OBJECT-TYPE    
  Dsx1XCurrentEntry  

dsx1CurrentLOS 1.3.6.1.4.1.164.3.1.6.4.1.2.1.1
The counter associated with the number of LOS seconds, encountered by a DS1 interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfCurrentCount  

dsx1CurrentLOF 1.3.6.1.4.1.164.3.1.6.4.1.2.1.2
The counter associated with the number of LOF seconds, encountered by a DS1 interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfCurrentCount  

dsx1CurrentLOC 1.3.6.1.4.1.164.3.1.6.4.1.2.1.3
Loss Of Cell delineation. Counts number of cells the ATM UNI cells receiver lost cells delineation .
Status: current Access: read-only
OBJECT-TYPE    
  PerfCurrentCount  

dsx1CurrentAIS 1.3.6.1.4.1.164.3.1.6.4.1.2.1.4
The counter associated with the number of AIS seconds, encountered by a DS1 interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfCurrentCount  

dsx1CurrentRAI 1.3.6.1.4.1.164.3.1.6.4.1.2.1.5
Remote Alarm Indication: Transmitted in the outgoing direction (toward the PABX) over FDL bits when the DS1 device detected an incoming Loss Of Frame. Received from the far end (PABX) over FDL when it detects a Loss of frame.
Status: current Access: read-only
OBJECT-TYPE    
  PerfCurrentCount  

dsx1CurrentLOMF 1.3.6.1.4.1.164.3.1.6.4.1.2.1.6
Loss of Multi-Frame sequence in E1 time slot 16.
Status: current Access: read-only
OBJECT-TYPE    
  PerfCurrentCount  

dsx1CurrentFEBE 1.3.6.1.4.1.164.3.1.6.4.1.2.1.7
Far End Block Errors, as reported in the first bit of frames 13 and 15, on multiframe E1 lines with CRC4, in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfCurrentCount  

dsx1CurrentStatus 1.3.6.1.4.1.164.3.1.6.4.1.2.1.8
The statuses of the current interval: 0 - Valid. 1 - redundantLinkSwitch - the link has been switched by a redundancy mechanism. 2 - discontinuity - module was partialy out. 4 - notValid - module is out.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(4)  

dsx1CurrentBPV 1.3.6.1.4.1.164.3.1.6.4.1.2.1.9
The counter associated with the number of BPVs (Bi-Polar Violations) encountered by a DS1 interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfCurrentCount  

dsx1CurrentLOCRCMF 1.3.6.1.4.1.164.3.1.6.4.1.2.1.10
Loss of CRC4 Multi-Frame sequence in E1. encountered in the current 15 minute interval
Status: current Access: read-only
OBJECT-TYPE    
  PerfCurrentCount  

dsx1CurrentLOFC 1.3.6.1.4.1.164.3.1.6.4.1.2.1.11
Counts the number of loss of frame events measured. encountered in the current 15 minute interval
Status: current Access: read-only
OBJECT-TYPE    
  PerfCurrentCount  

dsx1CurrentCRCErrors 1.3.6.1.4.1.164.3.1.6.4.1.2.1.12
Counts the number of CRC error events, encountered in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfCurrentCount  

dsx1XIntervalTable 1.3.6.1.4.1.164.3.1.6.4.1.3
A list of Interval entries. This table contains additional objects for the interval table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Dsx1XIntervalEntry

dsx1XIntervalEntry 1.3.6.1.4.1.164.3.1.6.4.1.3.1
An entry containing additional statistical counters applicable to a particular interval table.
Status: current Access: not-accessible
OBJECT-TYPE    
  Dsx1XIntervalEntry  

dsx1IntervalLOS 1.3.6.1.4.1.164.3.1.6.4.1.3.1.1
The counter associated with the number of LOS seconds , encountered by a DS1 interface in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  PerfIntervalCount  

dsx1IntervalLOF 1.3.6.1.4.1.164.3.1.6.4.1.3.1.2
The counter associated with the number of OOF seconds, encountered by a DS1 interface in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  PerfIntervalCount  

dsx1IntervalLOC 1.3.6.1.4.1.164.3.1.6.4.1.3.1.3
Loss Of Cell delineation. Counts number of cells the ATM UNI cells receiver lost cells delineation .
Status: current Access: read-only
OBJECT-TYPE    
  PerfIntervalCount  

dsx1IntervalAIS 1.3.6.1.4.1.164.3.1.6.4.1.3.1.4
The counter associated with the number of AIS seconds, encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  PerfIntervalCount  

dsx1IntervalRAI 1.3.6.1.4.1.164.3.1.6.4.1.3.1.5
Remote Alarm Indication: Transmitted in the outgoing direction (toward the PABX) over FDL bits when the DS1 device detected an incoming Loss Of Frame. Received from the far end (PABX) over FDL when it detects a Loss of frame.
Status: current Access: read-only
OBJECT-TYPE    
  PerfIntervalCount  

dsx1IntervalLOMF 1.3.6.1.4.1.164.3.1.6.4.1.3.1.6
Loss of Multi-Frame sequence in E1 time slot 16.
Status: current Access: read-only
OBJECT-TYPE    
  PerfIntervalCount  

dsx1IntervalFEBE 1.3.6.1.4.1.164.3.1.6.4.1.3.1.7
Far End Block Errors, as reported in the first bit of frames 13 and 15, on multiframe E1 lines with CRC4, in one of the previous 96, individual, 15 minute intervals.
Status: current Access: read-only
OBJECT-TYPE    
  PerfIntervalCount  

dsx1IntervalStatus 1.3.6.1.4.1.164.3.1.6.4.1.3.1.8
The statuses of the current interval: 0 - Valid. 1 - redundantLinkSwitch - the link has been switched by a redundancy mechanism. 2 - discontinuity - module was partialy out. 4 - notValid - module is out.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(4)  

dsx1IntervalBPV 1.3.6.1.4.1.164.3.1.6.4.1.3.1.9
The counter associated with the number of BPV (Bi-Polar Violations) encountered by a DS1 interface in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  PerfIntervalCount  

dsx1IntervalLOCRCMF 1.3.6.1.4.1.164.3.1.6.4.1.3.1.10
Loss of CRC4 Multi-Frame sequence in E1.
Status: current Access: read-only
OBJECT-TYPE    
  PerfIntervalCount  

dsx1IntervalLOFC 1.3.6.1.4.1.164.3.1.6.4.1.3.1.11
Counts the number of loss of frame events measured in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  PerfIntervalCount  

dsx1XTotalTable 1.3.6.1.4.1.164.3.1.6.4.1.4
A list of Total statistics entries. This table contains additional objects for the Total table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Dsx1XTotalEntry

dsx1XTotalEntry 1.3.6.1.4.1.164.3.1.6.4.1.4.1
An entry containing additional statistical counters applicable to a particular current table.
Status: current Access: not-accessible
OBJECT-TYPE    
  Dsx1XTotalEntry  

dsx1TotalLOS 1.3.6.1.4.1.164.3.1.6.4.1.4.1.1
The counter associated with the number of LOS (Loss of Signal) seconds encountered by a DS1 interface in the previous 24 hour interval. Invalid 15 minute intervals count as 0.
Status: current Access: read-only
OBJECT-TYPE    
  PerfTotalCount  

dsx1TotalBPV 1.3.6.1.4.1.164.3.1.6.4.1.4.1.9
The counter associated with the number of BPV (Bi-Polar Violations) encountered by a DS1 interface in the previous 24 hour interval. Invalid 15 minute intervals count as 0.
Status: current Access: read-only
OBJECT-TYPE    
  PerfTotalCount  

dsx1TotalLOFC 1.3.6.1.4.1.164.3.1.6.4.1.4.1.11
The counter associated with the number loss of frames encountered by a DS1 interface in the previous 24 hour interval. Invalid 15 minute intervals count as 0.
Status: current Access: read-only
OBJECT-TYPE    
  PerfTotalCount  

dsx1DataStreamStatTable 1.3.6.1.4.1.164.3.1.6.4.1.5
The DS1 Data Stream Statistics table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Dsx1DataStreamStatEntry

dsx1DataStreamStatEntry 1.3.6.1.4.1.164.3.1.6.4.1.5.1
An entry in the DS1 Data Stream Statistics table.
Status: current Access: not-accessible
OBJECT-TYPE    
  Dsx1DataStreamStatEntry  

dsx1DataStreamStatIfIndex 1.3.6.1.4.1.164.3.1.6.4.1.5.1.1
The index of the DS1 interface. It may be ifIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

dsx1DataStreamStatIndex 1.3.6.1.4.1.164.3.1.6.4.1.5.1.2
The DS1 Data Stream Index. For Vmux - the following indices are used: 1 for Transparent 2-3 for SS71-SS72 (respectively) 4-7 for Data1-Data4 (respectively) 8 for HDLC Ph2 Compatible 9-16 for Sub-CH1-1...Sub-CH1-8 (respectively).
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

dsx1DataStreamStatValid 1.3.6.1.4.1.164.3.1.6.4.1.5.1.3
Indicates whether this Data Stream is valid or not. When invalid - all counters are irrelevant.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

dsx1DataStreamStatInFrames 1.3.6.1.4.1.164.3.1.6.4.1.5.1.4
The counter associated with the number of received frames, encountered by the DS1 Data Stream.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

dsx1DataStreamStatInBytes 1.3.6.1.4.1.164.3.1.6.4.1.5.1.5
The counter associated with the number of received bytes, encountered by the DS1 Data Stream.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

dsx1DataStreamStatInDiscards 1.3.6.1.4.1.164.3.1.6.4.1.5.1.6
The counter associated with the number of Discarded incoming frames, encountered by the DS1 Data Stream.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

dsx1DataStreamStatInErrors 1.3.6.1.4.1.164.3.1.6.4.1.5.1.7
The counter associated with the number of received Errored frames, encountered by the DS1 Data Stream.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

dsx1DataStreamStatOutFrames 1.3.6.1.4.1.164.3.1.6.4.1.5.1.8
The counter associated with the number of transmitted frames, encountered by the DS1 Data Stream.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

dsx1DataStreamStatOutBytes 1.3.6.1.4.1.164.3.1.6.4.1.5.1.9
The counter associated with the number of transmitted bytes, encountered by the DS1 Data Stream.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

dsx1DataStreamStatOutDiscards 1.3.6.1.4.1.164.3.1.6.4.1.5.1.10
The counter associated with the number of Discarded outgoing frames, encountered by the DS1 Data Stream.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

dsx1DataStreamStatOutErrors 1.3.6.1.4.1.164.3.1.6.4.1.5.1.11
The counter associated with the number of errored transmitted frames, encountered by the DS1 Data Stream.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

dsx1XConfigTable 1.3.6.1.4.1.164.3.1.6.4.2
An extension to the DS1 Configuration table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Dsx1XConfigEntry

dsx1XConfigEntry 1.3.6.1.4.1.164.3.1.6.4.2.1
An entry containing additional configuration parameters.
Status: current Access: not-accessible
OBJECT-TYPE    
  Dsx1XConfigEntry  

dsx1IdleCode 1.3.6.1.4.1.164.3.1.6.4.2.1.1
Byte pattern of the data received/transmitted in the E1T1 framer idle timeslots. Valid range: (0 - FF HEX).
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

dsx1LineMode 1.3.6.1.4.1.164.3.1.6.4.2.1.2
T1 device operation mode. Valid for T1 only.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER csu(1), dsu(2)  

dsx1dBTxGain 1.3.6.1.4.1.164.3.1.6.4.2.1.3
Transmit line Gain for T1 CSU line mode.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), neg75dB(2), neg15dB(3), neg225dB(4), zerodB(5)  

dsx1RxSensitivity 1.3.6.1.4.1.164.3.1.6.4.2.1.4
Low Sensitivity is considered Short Haul while High Sensitivity is considered Long Haul. The actual values depend on the LIU. Examples: - E1: -12dB is considered Short Haul ; -43dB is considered Long Haul - T1: -12dB is considered Short Haul ; -36dB is considered Long Haul.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), longHaul(2), shortHaul(3)  

dsx1RestoreTime 1.3.6.1.4.1.164.3.1.6.4.2.1.5
Used to change the sync. algorithms to reduce the time required for the port to return to normal operation after a RED alarm. 'sec1' = Fast, 'sec10' = TR-6211, 'immediate' = CCITT
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER other(1), sec1(2), sec10(3), immediate(4)  

dsx1TcFirstSignal 1.3.6.1.4.1.164.3.1.6.4.2.1.6
Trunk conditioning signal - value to be sent as a signal during the first 2.5 seconds after alarm detection. Range is 0x0..0xF. 0xFF is a NULL value. This variable is used also for Space Signaling Code (in this case 0xFF is not NULL).
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

dsx1TcSignal 1.3.6.1.4.1.164.3.1.6.4.2.1.7
Trunk conditioning signal value after alarm detection. Range is 0x1..0xF for E1, and 0x0..0xF for T1. This variable is used also for Space Signaling Code (E1 and T1).
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

dsx1TcPattern 1.3.6.1.4.1.164.3.1.6.4.2.1.8
Trunk conditioning data pattern to be sent upon a DS0 fail. Range is 0x0..0xFF. This variable used also for Out of Service Code.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

dsx1Scramble 1.3.6.1.4.1.164.3.1.6.4.2.1.9
Scrambling is an operation that randomizes the bits of the payload of the ATM cell by a polynom. This operation helps with the error detection mechanism of the HEC. Not applicable for E1. active - will scramble/descramble the payload ATM cell notActive - will not scramble/descramble.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), notActive(2), active(3)  

dsx1LineAdaptiveTimingMode 1.3.6.1.4.1.164.3.1.6.4.2.1.10
Enables end to end clock synchronization. Default value - off.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

dsx1TxClockSource 1.3.6.1.4.1.164.3.1.6.4.2.1.11
The source of Transmit Clock. 'loopTiming' indicates that the recovered receive clock is used as the transmit clock. 'localTiming' indicates that a local clock source is used or when an external clock is attached to the box containing the interface. 'throughTiming' indicates that recovered receive clock from another interface is used as the transmit clock. 'adaptive' indicates that the clock is recovered according to the received data flow rate. 'system' indicates that the system clock is used as the transmit clock.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER loopTiming(1), localTiming(2), throughTiming(3), adaptive(4), system(5)  

dsx1AisEnable 1.3.6.1.4.1.164.3.1.6.4.2.1.12
Enable/ disable AIS transmit when Ethernet cable (for TDMoIP) is out (disconnected).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

dsx1TsEchoCancel 1.3.6.1.4.1.164.3.1.6.4.2.1.13
This parameter defines for each TS whether Echo-Cancellation is on. Each bit represents one TS as follow: First octet bit'0' = TS#1, bit'7' = TS#8, .. 2nd octet bit'0' = TS#9,.., 4th octet bit'7' = TS#32. Octets and bits order is from left to right: [31,30,..24] [23..16] [15..8] [7..0] MSB LSB MSB LSB MSB LSB MSB LSB For each bit values are: 0 - Echo-Cancellation off. 1 - Echo-Cancellation on.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

dsx1EchoCancelerModule 1.3.6.1.4.1.164.3.1.6.4.2.1.14
This parameter indicates whether echo-cancellation module exists for this line.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notExist(2), exist(3)  

dsx1PortFunction 1.3.6.1.4.1.164.3.1.6.4.2.1.15
This object determines the ATM Mode over the physical port. uni - The port will function as an ATM UNI. ces - The port will function as a CES. ima - The port will function as an IMA-ATM. cesPsn - The port will function as a CES-PSN. abis - The port will function as an Abis.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), uni(2), ces(3), ima(4), cesPsn(5), abis(6)  

dsx1PortMultiplier 1.3.6.1.4.1.164.3.1.6.4.2.1.16
This object determines the data rate of each TS (Kbps units). This parameter is applicable for T1 only.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), r56(2), r64(3)  

dsx1LeasedLine 1.3.6.1.4.1.164.3.1.6.4.2.1.17
This parameter defines whether Line mode is regular (non Leased Line mode) or transparent (Leased Line mode).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

dsx1CsuLoop 1.3.6.1.4.1.164.3.1.6.4.2.1.18
This parameter defines where the CSU loop will be done: local - locally (by IPmux) towards the TDM device transparent - transferred to Remote Device that will send it to its connected TDM device. remote - Remote Device will close the loop towards the Local Device.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), local(2), transparent(3), remote(4)  

dsx1ClockSource 1.3.6.1.4.1.164.3.1.6.4.2.1.19
This entry specifies the source from which the clock will be taken. Refer to device specification for source Index
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

dsx1OosSignal 1.3.6.1.4.1.164.3.1.6.4.2.1.20
This parameter defines the value to be sent as a signal after alarm detection: 'Space' = both A and B signaling bits are forced to '0' during out-of-service periods. 'Mark' = both A and B signaling bits are forced to '1' during out-of-service periods. 'spaceMark' = A and B bits are forced to '0' for 2.5 seconds; then they are switched to '1' until out-of-service condition disappears. 'markSpace' = A and B bits are forced to '1' for 2.5 seconds; then they are switched to '0' until out-of-service condition disappears. - '0'= 0 for T1, 1 for E1, or user defined value for Space - '1'= 1 for T1, 0 for E1, or user defined value for Mark.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), space(2), mark(3), spaceMark(4), markSpace(5)  

dsx1BundleNextIndex 1.3.6.1.4.1.164.3.1.6.4.2.1.21
This parameter indicates the Next free Bundle Index for this DS1 port.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

dsx1CRC6CalcMode 1.3.6.1.4.1.164.3.1.6.4.2.1.22
This object determines the CRC6 Calculation mode. jtG704 =JT-G704 = the Japanese standard ituG704=ITU-G704 = the International standard This parameter is applicable for J1 only.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER jtG704(1), ituG704(2)  

dsx1SendUponFail 1.3.6.1.4.1.164.3.1.6.4.2.1.23
This object determines which notification will be sent to the other side upon fail of another interface. In Ipmux14 the notification is sent upon failure of the Ethernet link.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER oosCode(2), ais(3)  

ds1LocalMultiframeAlarmTrap 1.3.6.1.4.1.164.3.1.6.4.0.1
This trap indicates near end (Local) Loss of Multiframe Alignment, of the user E1 interface.
Status: current Access: read-write
NOTIFICATION-TYPE    

ds1RemoteMultiframeAlarmTrap 1.3.6.1.4.1.164.3.1.6.4.0.2
This trap indicates that the far end (remote) unit, connected to the user E1 interface, reports Loss of Multiframe Alignment.
Status: current Access: read-write
NOTIFICATION-TYPE    

ds1LinkFrameSlipTrap 1.3.6.1.4.1.164.3.1.6.4.0.3
This trap indicates that a Frame Slip occurred at the user DS1 interface. This usually indicates timing problems (incorrect selection of timing reference), on the user DS1 link.
Status: current Access: read-write
NOTIFICATION-TYPE    

ds1BpvErrorTrap 1.3.6.1.4.1.164.3.1.6.4.0.4
This trap indicates a Bipolar Violation (BPV) error has been detected at the user DS1 interface.
Status: current Access: read-write
NOTIFICATION-TYPE    

ds1ExcessiveBpvTrap 1.3.6.1.4.1.164.3.1.6.4.0.5
This trap indicates excessive number of Bipolar Violation errors (BPV) detected by the user DS1 interface
Status: current Access: read-write
NOTIFICATION-TYPE    

ds1Crc4ErrorTrap 1.3.6.1.4.1.164.3.1.6.4.0.6
This trap indicates that a frame with CRC-4 error has been detected at the user DS1 interface.
Status: current Access: read-write
NOTIFICATION-TYPE    

ds1ExcessiveErrorRatioTrap 1.3.6.1.4.1.164.3.1.6.4.0.7
This trap indicates that the error rate, detected at the user DS1 interface, on the frame synchronization bits is high, as defined by ITU-T Rec. G.732.
Status: current Access: read-write
NOTIFICATION-TYPE    

ds1RemoteSyncLossTrap 1.3.6.1.4.1.164.3.1.6.4.0.8
This trap indicates that the far-end (remote) unit, connected to user DS1 interface, reports Loss of Frame Alignment (Sync Loss).
Status: current Access: read-write
NOTIFICATION-TYPE    

ds1LocalSyncLossTrap 1.3.6.1.4.1.164.3.1.6.4.0.9
This trap indicates near end (Local) Loss of Frame Alignment failure (Sync Loss), of the user DS1 interface
Status: current Access: read-write
NOTIFICATION-TYPE    

ds1AisSyncLossTrap 1.3.6.1.4.1.164.3.1.6.4.0.10
This trap indicates near end (Local) Loss of Frame Alignment (Sync Loss), caused by the reception of AIS at the user DS1 interface.
Status: current Access: read-write
NOTIFICATION-TYPE    

ds1AisTrap 1.3.6.1.4.1.164.3.1.6.4.0.11
This trap indicates AIS being received at the user DS1 interface.
Status: current Access: read-write
NOTIFICATION-TYPE    

ds1NetworkRemoteLoopTrap 1.3.6.1.4.1.164.3.1.6.4.0.12
This trap indicates that a remote loopback has been activated, on the local uplink interface.
Status: current Access: read-write
NOTIFICATION-TYPE    

ds1RemoteLoopTrap 1.3.6.1.4.1.164.3.1.6.4.0.13
This trap indicates that a remote loopback has been activated, on the local user port.
Status: current Access: read-write
NOTIFICATION-TYPE    

ds1LocalLoopTrap 1.3.6.1.4.1.164.3.1.6.4.0.14
This trap indicates that a local loopback has been activated on the user port.
Status: current Access: read-write
NOTIFICATION-TYPE    

ds1ExcessiveFrameSlipTrap 1.3.6.1.4.1.164.3.1.6.4.0.15
This trap indicates that the number of Frame Slips detected at the user DS1 interface, during the last minute exceeds threshold. For LA-110, threshold value is 10. This usually indicates timing problems (incorrect selection of timing reference) on the user DS1.
Status: current Access: read-write
NOTIFICATION-TYPE    

ds1ExcessiveCrc4ErrorTrap 1.3.6.1.4.1.164.3.1.6.4.0.16
This trap indicates that the error rate detected on the CRC-4 bits at the user DS1 interface, is high.
Status: current Access: read-write
NOTIFICATION-TYPE    

ds1ExcessiveLocalMfAlarmTrap 1.3.6.1.4.1.164.3.1.6.4.0.17
This trap indicates that the number of local Loss of Multiframe Alignment events, detected at the user E1 interface during the last minute exceeds threshold. For LA-110, threshold value is 10.
Status: current Access: read-write
NOTIFICATION-TYPE    

ds1ExcessiveRemoteMfAlarmTrap 1.3.6.1.4.1.164.3.1.6.4.0.18
This trap indicates that the number of Loss of multiframe alignment events reported by the remote unit connected to the user E1 interface during the last minute exceeds threshold. For LA-110, threshold value is 10.
Status: current Access: read-write
NOTIFICATION-TYPE    

ds1ExcessiveRemoteSyncLossTrap 1.3.6.1.4.1.164.3.1.6.4.0.19
This trap indicates that the number of far end (remote) Loss of Synchronization alarms, reported by the user DS1 interface during the last minute, exceeds threshold. For LA-110, threshold value is 10.
Status: current Access: read-write
NOTIFICATION-TYPE    

ds1ExcessiveLocalSyncLossTrap 1.3.6.1.4.1.164.3.1.6.4.0.20
This trap indicates that the number of Loss of local Synchronization alarms reported by the user DS1 interface during the last minute, exceeds threshold. For LA-110, threshold value is 10.
Status: current Access: read-write
NOTIFICATION-TYPE    

ds1SignalLossTrap 1.3.6.1.4.1.164.3.1.6.4.0.21
This trap indicates Signal Loss. (possible reason - cable disconnection. etc.)
Status: current Access: read-write
NOTIFICATION-TYPE    

ds3Interface 1.3.6.1.4.1.164.3.1.6.3
OBJECT IDENTIFIER    

prtDs3PerfHistory 1.3.6.1.4.1.164.3.1.6.3.1
OBJECT IDENTIFIER    

prtSDs3IfTable 1.3.6.1.4.1.164.3.1.6.3.1.1
The DS3 interface table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtDs3IfEntry

prtDs3IfEntry 1.3.6.1.4.1.164.3.1.6.3.1.1.1
An entry in the DS3 interface table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtDs3IfEntry  

prtDs3IfTimeElapsed 1.3.6.1.4.1.164.3.1.6.3.1.1.1.1
The number of seconds that have elapsed since the beginning of the near end current error- measurement period.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..899  

prtDs3IfValidIntervals 1.3.6.1.4.1.164.3.1.6.3.1.1.1.2
The number of previous near end intervals for which valid data was collected. The value will be 96 unless the interface was brought online within the last 24 hours, in which case the value will be the number of complete 15 minute near end intervals since the interface has been online.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..96  

prtDs3CurrentTable 1.3.6.1.4.1.164.3.1.6.3.1.2
The DS3 Current table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtDs3CurrentEntry

prtDs3CurrentEntry 1.3.6.1.4.1.164.3.1.6.3.1.2.1
An entry in the DS3 Current table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtDs3CurrentEntry  

prtDs3CurrentLOS 1.3.6.1.4.1.164.3.1.6.3.1.2.1.1
The counter associated with the number of LOS seconds, encountered by a DS3 interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtDs3CurrentOOF 1.3.6.1.4.1.164.3.1.6.3.1.2.1.2
The counter associated with the number of OOF seconds, encountered by a DS3 interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtDs3CurrentLOC 1.3.6.1.4.1.164.3.1.6.3.1.2.1.3
The counter associated with the number of LOC seconds, encountered by a DS3 interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtDs3CurrentAIS 1.3.6.1.4.1.164.3.1.6.3.1.2.1.4
The counter associated with the number of AIS seconds, encountered by a DS3 interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtDs3CurrentRDI 1.3.6.1.4.1.164.3.1.6.3.1.2.1.5
The counter associated with the number of RDI seconds, encountered by a DS3 interface.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtDs3CurrentUAS 1.3.6.1.4.1.164.3.1.6.3.1.2.1.6
The counter associated with the number of UAS, encountered by a SONET interface.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtDs3CurrentBIP 1.3.6.1.4.1.164.3.1.6.3.1.2.1.7
The counter associated with the number of BIP errors, encountered by a DS3 interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtDs3CurrentFEBE 1.3.6.1.4.1.164.3.1.6.3.1.2.1.8
The counter associated with the number of FEBE errors, encountered by a DS3 interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtDs3CurrentSLM 1.3.6.1.4.1.164.3.1.6.3.1.2.1.9
The counter associated with the number of SLM seconds, encountered by an E3 (only ) interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtDs3CurrentSES 1.3.6.1.4.1.164.3.1.6.3.1.2.1.10
The counter associated with the number of SES encountered by a E3 interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtDs3CurrentES 1.3.6.1.4.1.164.3.1.6.3.1.2.1.11
The number of Errored Seconds, encountered by a DS3 interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtDs3CurrentBitParity 1.3.6.1.4.1.164.3.1.6.3.1.2.1.12
Bit Parity Error counter. Relevant to T3 only.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtDs3CurrentPlcpLOF 1.3.6.1.4.1.164.3.1.6.3.1.2.1.13
The counter associated with the number of LOF seconds, encountered by a DS3 interface in one of the previous 96, individual 15 minute, intervals. This counter is relevant for plcpInternal(5) or plcpExternal(6) configuration If frame types only.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtDs3CurrentPlcpRAI 1.3.6.1.4.1.164.3.1.6.3.1.2.1.14
Receiving Yellow/Remote Alarm Indication. This counter is relevant for PLCP (external/internal) frame types only.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtDs3CurrentPlcpBIP 1.3.6.1.4.1.164.3.1.6.3.1.2.1.15
The counter associated with the number of BIP errors, encountered by a DS3 interface in the current 15 minute interval. This counter is relevant for PLCP (external/internal) frame types only.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtDs3CurrentPlcpFEBE 1.3.6.1.4.1.164.3.1.6.3.1.2.1.16
The counter associated with the number of FEBE errors, encountered by a DS3 interface in the current 15 minute interval. This counter is relevant for PLCP (external/internal) frame types only.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtDs3CurrentBPV 1.3.6.1.4.1.164.3.1.6.3.1.2.1.17
Number of BPVs (Bi-Polar Violations) , encountered by a DS3 interface in the current 15 minute interval. This object is relevant only for Electrical Line of Fomi-E3/T3.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtDs3CurrentLCE 1.3.6.1.4.1.164.3.1.6.3.1.2.1.18
Number of LCE (Link Code Errors) encountered by a DS3 interface in the current 15 minute interval. This object is relevant only for Optical Links of Fomi-E3/T3.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtDs3CurrentStatus 1.3.6.1.4.1.164.3.1.6.3.1.2.1.19
The statuses of the current interval: 0 - Valid. 1 - redundantLinkSwitch - the link has been switched by a redundancy mechanism. 2 - discontinuity - module was partialy out. 4 - notValid - module is out.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(4)  

prtDs3IntervalTable 1.3.6.1.4.1.164.3.1.6.3.1.3
The DS3 Interval table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtDs3IntervalEntry

prtDs3IntervalEntry 1.3.6.1.4.1.164.3.1.6.3.1.3.1
An entry in the DS3 Interval table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtDs3IntervalEntry  

prtDs3IntervalNumber 1.3.6.1.4.1.164.3.1.6.3.1.3.1.1
A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..96  

prtDs3IntervalLOS 1.3.6.1.4.1.164.3.1.6.3.1.3.1.2
The counter associated with the number of LOS seconds , encountered by a DS3 interface in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtDs3IntervalOOF 1.3.6.1.4.1.164.3.1.6.3.1.3.1.3
The counter associated with the number of OOF seconds, encountered by a DS3 interface in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtDs3IntervalLOC 1.3.6.1.4.1.164.3.1.6.3.1.3.1.4
The counter associated with the number of LOC seconds, encountered by a DS3 interface in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtDs3IntervalAIS 1.3.6.1.4.1.164.3.1.6.3.1.3.1.5
The counter associated with the number of AIS seconds, encountered by a SONET interface in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtDs3IntervalRDI 1.3.6.1.4.1.164.3.1.6.3.1.3.1.6
The counter associated with the number of RDI seconds, encountered by a DS3 interface in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtDs3IntervalUAS 1.3.6.1.4.1.164.3.1.6.3.1.3.1.7
The counter associated with the number of UAS, encountered by a DS3 interface in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtDs3IntervalBIP 1.3.6.1.4.1.164.3.1.6.3.1.3.1.8
The counter associated with the number of BIP errors, encountered by a DS3 interface in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtDs3IntervalFEBE 1.3.6.1.4.1.164.3.1.6.3.1.3.1.9
The counter associated with the number of FEBE errors, encountered by a DS3 interface in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtDs3IntervalSLM 1.3.6.1.4.1.164.3.1.6.3.1.3.1.10
The counter associated with the number of SLM seconds, encountered by an E3 interface in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtDs3IntervalSES 1.3.6.1.4.1.164.3.1.6.3.1.3.1.11
The counter associated with the number of SES encountered by a E3 interface in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtDs3IntervalES 1.3.6.1.4.1.164.3.1.6.3.1.3.1.12
The number of Errored Seconds, encountered by a DS3 interface in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtDs3IntervalBitParity 1.3.6.1.4.1.164.3.1.6.3.1.3.1.13
Bit Parity Error counter. Relevant to T3 only.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtDs3IntervalPlcpLOF 1.3.6.1.4.1.164.3.1.6.3.1.3.1.14
The counter associated with the number of LOF seconds, encountered by a DS3 interface in one of the previous 96, individual 15 minute, intervals. This counter is relevant for plcpInternal(5) or plcpExternal(6) configuration If frame types only.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtDs3IntervalPlcpRAI 1.3.6.1.4.1.164.3.1.6.3.1.3.1.15
Receiving Yellow/Remote Alarm Indication. This counter is relevant for PLCP (external/internal) frame types only.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtDs3IntervalPlcpBIP 1.3.6.1.4.1.164.3.1.6.3.1.3.1.16
The counter associated with the number of BIP errors, encountered by a DS3 interface in the current 15 minute interval. This counter is relevant for PLCP (external/internal) frame types only.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtDs3IntervalPlcpFEBE 1.3.6.1.4.1.164.3.1.6.3.1.3.1.17
The counter associated with the number of FEBE errors, encountered by a DS3 interface in the current 15 minute interval. This counter is relevant for PLCP (external/internal) frame types only.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtDs3IntervalBPV 1.3.6.1.4.1.164.3.1.6.3.1.3.1.18
Number of BPVs (Bi-Polar Violations) , encountered by a DS3 interface in the specified 15 minute interval. This object is relevant only for Electrical Line of Fomi-E3/T3.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtDs3IntervalLCE 1.3.6.1.4.1.164.3.1.6.3.1.3.1.19
Number of LCE (Link Code Errors) encountered by a DS3 interface in the specified 15 minute interval. This object is relevant only for Optical Links of Fomi-E3/T3.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtDs3IntervalStatus 1.3.6.1.4.1.164.3.1.6.3.1.3.1.20
The statuses of the current interval: 0 - Valid. 1 - redundantLinkSwitch - the link has been switched by a redundancy mechanism. 2 - discontinuity - module was partialy out. 4 - notValid - module is out.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(4)  

prtDs3TotalTable 1.3.6.1.4.1.164.3.1.6.3.1.4
A list of Total entries.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtDs3TotalEntry

prtDs3TotalEntry 1.3.6.1.4.1.164.3.1.6.3.1.4.1
An entry of Total table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtDs3TotalEntry  

prtDs3TotalUAS 1.3.6.1.4.1.164.3.1.6.3.1.4.1.6
Number of UASs (Unavailable Seconds) , encountered by a DS3 interface in the previous 96 intervals. Invalid 15 minute intervals count as 0.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtDs3TotalBPV 1.3.6.1.4.1.164.3.1.6.3.1.4.1.17
Number of BPVs (Bi-Polar Violations) , encountered by a DS3 interface in the previous 96 intervals. Invalid 15 minute intervals count as 0.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtDs3TotalLCE 1.3.6.1.4.1.164.3.1.6.3.1.4.1.18
Number of LCE (Link Code Errors) encountered by a DS3 interface in the previous 96 intervals. Invalid 15 minute intervals count as 0.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtDs3TotalSES 1.3.6.1.4.1.164.3.1.6.3.1.4.1.19
Number of SES (Severely Errored Seconds) encountered by a DS3 interface in the previous 96 intervals. Invalid 15 minute intervals count as 0.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

dsx3XConfigTable 1.3.6.1.4.1.164.3.1.6.3.2
An extension to the DS3 Configuration table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Dsx3XConfigEntry

dsx3XConfigEntry 1.3.6.1.4.1.164.3.1.6.3.2.1
An entry containing additional configuration parameters.
Status: current Access: not-accessible
OBJECT-TYPE    
  Dsx3XConfigEntry  

dsx3AisEnable 1.3.6.1.4.1.164.3.1.6.3.2.1.1
Enable/ disable AIS transmit when Ethernet (for TDMoIP) line is disconnected.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

dsx3TxClockSource 1.3.6.1.4.1.164.3.1.6.3.2.1.2
The source of Transmit Clock. loopTiming indicates that the recovered receive clock is used as the transmit clock. localTiming indicates that a local clock source is used or that an external clock is attached to the box containing the interface. throughTiming indicates that transmit clock is derived from the recovered receive clock of another DS3 interface. 'system' indicates that the system clock is used as the transmit clock.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER loopTiming(1), localTiming(2), throughTiming(3), system(4)  

dsx3MappingTable 1.3.6.1.4.1.164.3.1.6.3.3
The DS3/E3 mapping table associates DS3/E3 channels with logical or physical interfaces. For example, consider a DS3 device with 16 T1's and 1 VCG. There are 28 logical/internal channels, numbered 1 through 28 but only 17 are actually connected. We might describe the allocation of channels, in the dsx3MappingTable, as follows: dsx3MappingIfIndex.1. 1 = 1001 dsx3MappingIfIndex.1.15 = 1015 dsx3MappingIfIndex.1. 2 = 1002 dsx3MappingIfIndex.1.16 = 1016 dsx3MappingIfIndex.1. 3 = 1003 dsx3MappingIfIndex.1.17 = 1017 dsx3MappingIfIndex.1. 4 = 1004 dsx3MappingIfIndex.1.18 = 0 dsx3MappingIfIndex.1. 5 = 1005 dsx3MappingIfIndex.1.19 = 0 dsx3MappingIfIndex.1. 6 = 1006 dsx3MappingIfIndex.1.20 = 0 dsx3MappingIfIndex.1. 7 = 1007 dsx3MappingIfIndex.1.21 = 0 dsx3MappingIfIndex.1. 8 = 1008 dsx3MappingIfIndex.1.22 = 0 dsx3MappingIfIndex.1. 9 = 1009 dsx3MappingIfIndex.1.23 = 0 dsx3MappingIfIndex.1.10 = 1010 dsx3MappingIfIndex.1.24 = 0 dsx3MappingIfIndex.1.11 = 1011 dsx3MappingIfIndex.1.25 = 0 dsx3MappingIfIndex.1.12 = 1012 dsx3MappingIfIndex.1.26 = 0 dsx3MappingIfIndex.1.13 = 1013 dsx3MappingIfIndex.1.27 = 0 dsx3MappingIfIndex.1.14 = 1014 dsx3MappingIfIndex.1.28 = 0 Note that in the case above all channels are mapped to one T3 port with ifIndex = 1. The Channels 1...28 are represented via the 2nd index. The values of 1001...1016 are the T1 interface ifIndexes. The value of 1017 is the ifIndex of the VCG. Unconnected channels have a value of 0.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Dsx3MappingEntry

dsx3MappingEntry 1.3.6.1.4.1.164.3.1.6.3.3.1
An entry in the DS3 mapping table.
Status: deprecated Access: not-accessible
OBJECT-TYPE    
  Dsx3MappingEntry  

dsx3MappingDs3Index 1.3.6.1.4.1.164.3.1.6.3.3.1.1
The index value which uniquely identifies the DS3/E3 interface to which this entry is applicable. This value is also equal to dsx3LineIndex used in dsx3ConfigEntry. For RICi-16 this is the ifIndex of the T3 interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  InterfaceIndex  

dsx3MappingNumber 1.3.6.1.4.1.164.3.1.6.3.3.1.2
The channel number for this entry. For RICi-16 this is the channel number 1...28.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

dsx3MappingIfIndex 1.3.6.1.4.1.164.3.1.6.3.3.1.3
An index value that uniquely identifies a logical or physical interface mapped to a DS3/E3 channel. If no interface is currently using a channel, the value should be zero. If a single interface occupies more than one channel, that ifIndex value will be found in multiple channels. For RICi-16 this is the ifIndex of the T1 or VCG interface.
Status: current Access: read-write
OBJECT-TYPE    
  InterfaceIndex  

atmNte 1.3.6.1.4.1.164.12.3
OBJECT IDENTIFIER    

atmNtePrt 1.3.6.1.4.1.164.12.3.2
OBJECT IDENTIFIER    

atmNtePrtConfig 1.3.6.1.4.1.164.12.3.2.1
OBJECT IDENTIFIER    

atmNteEvents 1.3.6.1.4.1.164.12.3.0
The events for RAD ATM products.
Status: current Access: read-write
OBJECT-IDENTITY    

atmNteConfIfTable 1.3.6.1.4.1.164.12.3.2.1.1
The Physical interface configuration table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmNteConfIfEntry

atmNteConfIfEntry 1.3.6.1.4.1.164.12.3.2.1.1.1
An entry in the Physical interface configuration table. The ifIndex is of the lowest physical layer.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmNteConfIfEntry  

atmConfIfTransmitClk 1.3.6.1.4.1.164.12.3.2.1.1.1.1
The transmit clock of the port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER internal(2), external(3), loopback(4), adaptive(5)  

atmConfIfLoopback 1.3.6.1.4.1.164.12.3.2.1.1.1.2
Interface Loopback.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER internal(2), external(3), disable(4)  

atmConfIfFrameType 1.3.6.1.4.1.164.12.3.2.1.1.1.3
The frame type. Valid values for a 155M interface: sonet(2), sdh(3). Valid values for a T3 interface: direct(4), plcpInternal(5), plcpExternal(6), directNoScrmbling(10), plcpInternalNoScrmbling(11), plcpExternalNoScrmbling(12). Valid values for Ethernet interface: ethCrcTrans (8), ethCrcNotTrans(9). (DS1 interfaces frame type is specified in the DSX1 mib).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER other(1), sonet(2), sdh(3), direct(4), plcpInternal(5), plcpExternal(6), e3(7), ethCrcTrans(8), ethCrcNotTrans(9), directNoScrmbling(10), plcpInternalNoScrmbling(11), plcpExternalNoScrmbling(12)  

atmConfIfCardType 1.3.6.1.4.1.164.12.3.2.1.1.1.4
The card type.
Status: deprecated Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), sc13m-155(2), st13s-155(3), st13l-155(4), utp-155(5), cx-bnc-155(6), e3(7), t3(8), e1(9), e1-ltu(10), fc13l-155(11), fc13lh-155(12), fc15lh-155(13), fc13l-e3(14), fc13lh-e3(15), fc15lh-e3(16), fc13l-t3(17), fc13lh-t3(18), fc15lh-t3(19)  

atmConfAtmIfVpiVciLimit 1.3.6.1.4.1.164.12.3.2.1.1.1.5
The limit on the sum of the VPI+VCI bits for this interface.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER bits15(2), bits17(3)  

atmConfIfHwFeatures 1.3.6.1.4.1.164.12.3.2.1.1.1.6
HW features command.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

atmConfIfOutputRate 1.3.6.1.4.1.164.12.3.2.1.1.1.7
This parameter indicates the output rate in cells/sec, which is supported per port. Successfully setting this parameter is dependent on all other ports values calculations, which are described in the NMS SRS.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmConfIfInputRate 1.3.6.1.4.1.164.12.3.2.1.1.1.8
This parameter indicates the input rate in cells/sec, which is supported per port. Successfully setting this parameter is dependent on all other ports values calculations, which are described in the NMS SRS.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmConfAlarmForwarding 1.3.6.1.4.1.164.12.3.2.1.1.1.9
Enables Path AIS Alarm forwarding upon a failure detection. The following might be considered as a failure: LOS, LOF, LOC, SLM, LOP, Path AIS and Line AIS. disable(2) - will not forward an alarm upon a failure on this port. enable(3) - will forward an alarm upon a failure on this port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(2), enable(3)  

atmConfIfAllocatedBw 1.3.6.1.4.1.164.12.3.2.1.1.1.10
Total VC Bandwidth Allocation.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmConfIfLowerVpi 1.3.6.1.4.1.164.12.3.2.1.1.1.11
The Lower possible VPI.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmConfIfOamMode 1.3.6.1.4.1.164.12.3.2.1.1.1.12
OAM support Mode, which determines the interface's location in a segment wise.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER segmentTermination(2), endToEndTermination(3)  

atmConfIfOamFailureInd 1.3.6.1.4.1.164.12.3.2.1.1.1.13
This object allows user to define the type of indication (if any) that will be created upon a LB cell failure, for all VCs on which OAM loopback traffic is activated. disabled(2) - no indication will be created. ais(3) - will cause Tx of AIS. rdi(4) - will cause Tx of RDI. aisAndRdi(5) - will cause Tx of AIS & RDI. For LA-110, indication will be sent only for VCs with atmConfVcLoopbackFailureInd <> disabled
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(2), ais(3), rdi(4), aisAndRdi(5)  

atmNteAlarmIfTable 1.3.6.1.4.1.164.12.3.2.1.2
The interface Alarm table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmNteAlarmIfEntry

atmNteAlarmIfEntry 1.3.6.1.4.1.164.12.3.2.1.2.1
An entry in the interface Alarm table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmNteAlarmIfEntry  

atmInterfaceActiveAlarms 1.3.6.1.4.1.164.12.3.2.1.2.1.1
A Bit String of the active alarms on this interface. An up bit (1) means there is an active alarm of this type. A down bit (0) means there is no such alarm. The meaning of the bits is as follows: 1 - LOS 2 - LOF 3 - Line AIS (SONET)/ PLCP LOF (DS3) 4 - LOP 5 - Path AIS 6 - SLM 7 - LCD 8 - Line RDI (SONET)/ PLCP Yellow (DS3) 9 - Path RDI (SONET)/ RDI (DS3) 10 - Section BIP (SONET)/ P1/P2 (DS3) > Threshold 11 - Line BIP (SONET)/ PLCP BIP (DS3) > Threshold 12 - Line FEBE (SONET)/ PLCP FEBE (DS3) > Threshold 13 - Path BIP > Threshold 14 - Path FEBE > Threshold 15 - HW Failure
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmThresholdSectionBIP 1.3.6.1.4.1.164.12.3.2.1.2.1.2
When Section BIPs are greater than this threshold, an active alarm is raised. N/A for ds3/e3 interface.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmThresholdLineBIP 1.3.6.1.4.1.164.12.3.2.1.2.1.3
When Line BIPs are greater than this threshold, an active alarm is raised. N/A for ds3/e3 interface.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmThresholdLineFEBE 1.3.6.1.4.1.164.12.3.2.1.2.1.4
When Line FEBEs are greater than this threshold, an active alarm is raised. N/A for ds3/e3 interface.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmThresholdPathBIP 1.3.6.1.4.1.164.12.3.2.1.2.1.5
When Path BIPs are greater than this threshold, an active alarm is raised.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmThresholdPathFEBE 1.3.6.1.4.1.164.12.3.2.1.2.1.6
When Path FEBEs are greater than this threshold, an active alarm is raised.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmThresholdErroredCells 1.3.6.1.4.1.164.12.3.2.1.2.1.7
When Errored Cells are greater than this threshold, an active alarm is raised.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmThresholdLostCells 1.3.6.1.4.1.164.12.3.2.1.2.1.8
When Lost Cells are greater than this threshold, an active alarm is raised.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmThresholdMisinsertedCells 1.3.6.1.4.1.164.12.3.2.1.2.1.9
When Misinserted Cells are greater than this threshold, an active alarm is raised.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmInterfaceAlarmStatus 1.3.6.1.4.1.164.12.3.2.1.2.1.10
The variable is on(3) when there is any active alarm on this interface.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(2), on(3)  

atmInterfaceMaskAlarms 1.3.6.1.4.1.164.12.3.2.1.2.1.11
A Bit String of alarms mask on this interface. An up bit (1) means that the respective alarm is masked. A down bit (0) means no mask. The mask is supported for the following alarms: 1 - LOS
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmNteConfVpTable 1.3.6.1.4.1.164.12.3.2.1.3
The ATM VP configuration table. The table is an extension to the atmVplTable of RFC-1695.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmNteConfVpEntry

atmNteConfVpEntry 1.3.6.1.4.1.164.12.3.2.1.3.1
An entry in the ATM VP configuration table. ifIndex of the ATM layer.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmNteConfVpEntry  

atmConfVpPolicing 1.3.6.1.4.1.164.12.3.2.1.3.1.1
Policing method desired for this VPL.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), police(2), monitor(3), shaping(4), policingAndShaping(5)  

atmConfVpCCAdminStatus 1.3.6.1.4.1.164.12.3.2.1.3.1.2
up(2) - Activate Continuity Check (CC). down(3) - Deactivate CC. source(4) - Activate OAM CC(Continuity Check) of local agent ( start sending Oam cells to the remote side ). sink(5) - Activate CC of remote agent ( start receiving Oam cells from remote side ). listenToActivationCells (6) - Passive listener till gets an activation request originateActivationCells(7) - Sands Activation cell according to atmConfVcCCDirection.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER up(2), down(3), source(4), sink(5), listenToActivationCells(6), originateActivationCells(7)  

atmConfVpLoopbackAdminStatus 1.3.6.1.4.1.164.12.3.2.1.3.1.3
up(2) - Start loopback OAM cells. down(3) - Stop sending loopback OAM cells. For ace2002: up(2) - Transmitting LB cells with llid all ones (i.e. FFFF..FF) down(3) - Not transmitting LB cells. llid(4) - Transmitting LB cells with llid indicated in the address field. segment(5) - Transmitting Segment LB cells with llid all ones. endToEnd(6) - Transmitting End to End LB cells with llid all ones. segmentLlid(7) - Transmitting Segment LB cells with llid indicated in the address field. endToEndLlid(8) - Transmitting LB cells with llid indicated in the address field. This parameter value might be in conflict with atmConfVpOamSupport value, since this parameter is for LB, while atmConfVpOamSupport is for any other OAM cells.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER up(2), down(3), llid(4), segment(5), endToEnd(6), segmentLlid(7), endToEndLlid(8)  

atmConfVpLoopbackSinkAddress 1.3.6.1.4.1.164.12.3.2.1.3.1.4
Destination address. For ace101: 2 bytes are used. For ace2002: 16 bytes are used.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..20)  

atmConfVpCongestionControl 1.3.6.1.4.1.164.12.3.2.1.3.1.5
Each bit indicates a selection of one option as the following description. All combinations are possible and legal. The codes are: 1 - EPD 2 - CLP 4 - EFCI
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

atmConfVpCCDirection 1.3.6.1.4.1.164.12.3.2.1.3.1.6
both(2) - Agent send OAM CC cells and check received OAM CC cells source(4)- Agent send OAM CC cells. sink(5) - Agent checks received OAM CC cells.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER both(2), source(4), sink(5)  

atmConfVpCreationTime 1.3.6.1.4.1.164.12.3.2.1.3.1.7
A date-time in which the VP was created.
Status: current Access: read-only
OBJECT-TYPE    
  DateAndTime  

atmConfVpOamSupport 1.3.6.1.4.1.164.12.3.2.1.3.1.8
OAM support mode, which determines the device location in a segment wise.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER intermediate(1), segmentTermination(2), endToEndTermination(3)  

atmConfVpCCOperStatus 1.3.6.1.4.1.164.12.3.2.1.3.1.9
initial(1) - The CC activation process is not started. source(4) - Agent sends OAM CC cells. sink(5) - Agent checks received OAM CC cells. both (8) - OAM CC of local and remote agents activation. timeout (9) - Timeout occured on receiving answer from the remote agent. denied (10) - CC activation process rejected by remote agent. conflict (11) - local and remote sides requested activation simultaneously. manual (12) - OAM CC of local agent activated manually.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER initial(1), source(4), sink(5), both(8), timeout(9), denied(10), conflict(11), manual(12)  

atmConfVpLoopbackTraffic 1.3.6.1.4.1.164.12.3.2.1.3.1.10
This parameter has both command and status meanings: off(2) - Set to 'Off' will Stop traffic loop. Getting this value means that the loop is not running. on (3) - Set to 'On' will start traffic loop. Getting this value means that the loop is currently running.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

atmConfVpLoopbackFailureInd 1.3.6.1.4.1.164.12.3.2.1.3.1.11
This object allows user to define the Indication that will be created upon a LB cell failure. disabled(2) - no indication will be created. segmentAis(3) - will cause Tx of a segment AIS. segmentRdi(4) - will cause Tx of a segment RDI. segmentAisAndRdi(5) - will cause Tx of a segment AIS & RDI. endToEndAis(6) - will cause Tx of an End to End AIS. endToEndRdi(7) - will cause Tx of an End to End RDI. endToEndAisAndRdi(8) - will cause Tx of an End to End AIS & RDI. Default: disabled(2).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(2), segmentAis(3), segmentRdi(4), segmentAisAndRdi(5), endToEndAis(6), endToEndRdi(7), endToEndAisAndRdi(8)  

atmConfVpLoopbackFailureThreshold 1.3.6.1.4.1.164.12.3.2.1.3.1.12
The number of the LB failures before starting transmission of the Indication defined by atmConfVcLoopbackFailureInd. Range: 1..16. Default: 1.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmConfVpOamDirection 1.3.6.1.4.1.164.12.3.2.1.3.1.13
The direction of OAM cell insertion. downStream(2) - The OAM cell will be inserted in downStream. upStream(3) - The OAM cell will be inserted in upStream.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), downStream(2), upStream(3)  

atmConfVpOamDescrIndex 1.3.6.1.4.1.164.12.3.2.1.3.1.14
This parameter indicates the VPL's OAM Descriptor index, according to the OAM Descriptor Configuration Table.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmConfVpConnected 1.3.6.1.4.1.164.12.3.2.1.3.1.15
This object indicates whether this VP is connected and if connected, what is it connected to.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notConnected(1), mng(2), bridgePort(3), ds0Bundle(4), atm(5), pw(6)  

atmNteAlarmVpTable 1.3.6.1.4.1.164.12.3.2.1.5
The ATM VP Alarm table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmNteAlarmVpEntry

atmNteAlarmVpEntry 1.3.6.1.4.1.164.12.3.2.1.5.1
An entry in the ATM VP Alarm table. ifIndex of the ATM layer.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmNteAlarmVpEntry  

atmNteVpAlarmVpi 1.3.6.1.4.1.164.12.3.2.1.5.1.1
The VPI on which there is an active alarm.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmNteVpActiveAlarms 1.3.6.1.4.1.164.12.3.2.1.5.1.2
A Bit String of the active alarms on this VP. An up bit (1) means there is an active alarm of this type. A down bit (0) means there is no such alarm. The meaning of the bits is as follows: 1 - VP AIS 2 - VP Loss Of Continuity 3 - VP RDI Reception 4 - VP Errored Cells > Threshold 5 - VP Lost Cells > Threshold 6 - VP Misinserted Cells > Threshold 9 - VP Loopback Failure
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmNteAlarmVcTable 1.3.6.1.4.1.164.12.3.2.1.6
The ATM VC Alarm table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmNteAlarmVcEntry

atmNteAlarmVcEntry 1.3.6.1.4.1.164.12.3.2.1.6.1
An entry in the ATM VC Alarm table. ifIndex of the ATM layer.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmNteAlarmVcEntry  

atmNteVcAlarmVpi 1.3.6.1.4.1.164.12.3.2.1.6.1.1
The VPI of the VC on which there is an active alarm.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmNteVcAlarmVci 1.3.6.1.4.1.164.12.3.2.1.6.1.2
The VCI of the VC on which there is an active alarm.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmNteVcActiveAlarms 1.3.6.1.4.1.164.12.3.2.1.6.1.3
A Bit String of the active alarms on this VC. An up bit (1) means there is an active alarm of this type. A down bit (0) means there is no such alarm. The meaning of the bits is as follows: 1 - VC AIS 2 - VC Loss Of Continuity 3 - VC RDI 4 - VC Errored Cells > Threshold 5 - VC Lost Cells > Threshold 6 - VC Misinserted Cells > Threshold 7 - Tx VC AIS 8 - Tx VC RDI 9 - VC Loopback Failure
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmGen 1.3.6.1.4.1.164.12.2
OBJECT IDENTIFIER    

atmPerfHistory 1.3.6.1.4.1.164.12.2.1
OBJECT IDENTIFIER    

atmIfPerformance 1.3.6.1.4.1.164.12.2.1.1
OBJECT IDENTIFIER    

atmIfDataTable 1.3.6.1.4.1.164.12.2.1.1.1
The ATM interface Data table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmIfDataEntry

atmIfDataEntry 1.3.6.1.4.1.164.12.2.1.1.1.1
An entry in the ATM interface Data table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmIfDataEntry  

atmIfTimeElapsed 1.3.6.1.4.1.164.12.2.1.1.1.1.1
The number of seconds that have elapsed since the beginning of the near end current error- measurement period.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..899  

atmIfValidIntervals 1.3.6.1.4.1.164.12.2.1.1.1.1.2
The number of previous near end intervals for which valid data was collected. The value will be 96 unless the interface was brought online within the last 24 hours, in which case the value will be the number of complete 15 minute near end intervals since the interface has been online.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..96  

atmIfTxCells 1.3.6.1.4.1.164.12.2.1.1.1.1.3
The counter associated with the total number of transmitted cells, encountered by an ATM interface.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

atmIfRxCells 1.3.6.1.4.1.164.12.2.1.1.1.1.4
The counter associated with the total number of received cells, encountered by an ATM interface.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

atmIfUncorrectedHecs 1.3.6.1.4.1.164.12.2.1.1.1.1.5
The counter associated with the total number of cells with uncorrected HEC errors, encountered by an ATM interface.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

atmIfCurrentTable 1.3.6.1.4.1.164.12.2.1.1.2
The ATM interface Current table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmIfCurrentEntry

atmIfCurrentEntry 1.3.6.1.4.1.164.12.2.1.1.2.1
An entry in the ATM interface Current table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmIfCurrentEntry  

atmIfCurrentTxCells 1.3.6.1.4.1.164.12.2.1.1.2.1.1
The counter associated with the number of transmitted cells, encountered by an ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmIfCurrentRxCells 1.3.6.1.4.1.164.12.2.1.1.2.1.2
The counter associated with the number of received cells, encountered by an ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmIfCurrentCorrectedHecs 1.3.6.1.4.1.164.12.2.1.1.2.1.3
The counter associated with the number of cells with corrected HEC errors, encountered by an ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmIfCurrentUncorrectedHecs 1.3.6.1.4.1.164.12.2.1.1.2.1.4
The counter associated with the number of cells with uncorrected HEC errors, encountered by an ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmIfCurrentHecErrorSeconds 1.3.6.1.4.1.164.12.2.1.1.2.1.5
The counter associated with the number of seconds with HEC errors, encountered by an ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmIfIntervalTable 1.3.6.1.4.1.164.12.2.1.1.3
The ATM interface Interval table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmIfIntervalEntry

atmIfIntervalEntry 1.3.6.1.4.1.164.12.2.1.1.3.1
An entry in the ATM interface Interval table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmIfIntervalEntry  

atmIfIntervalNumber 1.3.6.1.4.1.164.12.2.1.1.3.1.1
A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..96  

atmIfIntervalTxCells 1.3.6.1.4.1.164.12.2.1.1.3.1.2
The counter associated with the number of transmitted cells , encountered by an ATM interface in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmIfIntervalRxCells 1.3.6.1.4.1.164.12.2.1.1.3.1.3
The counter associated with the number of received cells, encountered by an ATM interface in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmIfIntervalCorrectedHecs 1.3.6.1.4.1.164.12.2.1.1.3.1.4
The counter associated with the number of cells with corrected HEC errors, encountered by an ATM interface in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmIfIntervalUncorrectedHecs 1.3.6.1.4.1.164.12.2.1.1.3.1.5
The counter associated with the number of cells with uncorrected HEC errors, encountered by an ATM interface in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmIfIntervalHecErrorSeconds 1.3.6.1.4.1.164.12.2.1.1.3.1.6
The counter associated with the number of seconds with HEC errors, encountered by an ATM interface in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmPvcPerformance 1.3.6.1.4.1.164.12.2.1.2
OBJECT IDENTIFIER    

atmVpPerformance 1.3.6.1.4.1.164.12.2.1.2.1
OBJECT IDENTIFIER    

atmVpCurrentTable 1.3.6.1.4.1.164.12.2.1.2.1.1
The ATM VP Current table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmVpCurrentEntry

atmVpCurrentEntry 1.3.6.1.4.1.164.12.2.1.2.1.1.1
An entry in the ATM VP Current table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmVpCurrentEntry  

atmVpCurrentVpi 1.3.6.1.4.1.164.12.2.1.2.1.1.1.1
The VPI of the VPL.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmVpCurrentRxCellsClp01 1.3.6.1.4.1.164.12.2.1.2.1.1.1.2
The counter associated with the number of transmitted cells, encountered by the VPL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpCurrentRxCellsClp0 1.3.6.1.4.1.164.12.2.1.2.1.1.1.3
The counter associated with the number of received cells, encountered by the VPL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpCurrentGcra0Violations 1.3.6.1.4.1.164.12.2.1.2.1.1.1.4
The counter associated with the number of cells violating GCRA0, encountered by the VPL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpCurrentGcra1Violations 1.3.6.1.4.1.164.12.2.1.2.1.1.1.5
The counter associated with the number of cells violating GCRA1, encountered by the VPL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpCurrentRxAIS 1.3.6.1.4.1.164.12.2.1.2.1.1.1.6
The counter associated with the number of received AIS cells, encountered by the VPL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpCurrentTxAIS 1.3.6.1.4.1.164.12.2.1.2.1.1.1.7
The counter associated with the number of transmitted AIS cells, encountered by the VPL of this ATM interface in the current 15 minute interval. Not Supported in the first phase.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpCurrentRxRDI 1.3.6.1.4.1.164.12.2.1.2.1.1.1.8
The counter associated with the number of received RDI cells, encountered by the VPL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpCurrentTxRDI 1.3.6.1.4.1.164.12.2.1.2.1.1.1.9
The counter associated with the number of transmitted RDI cells, encountered by the VPL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpCurrentContinuityLoss 1.3.6.1.4.1.164.12.2.1.2.1.1.1.10
The counter associated with the number of loss of continuity cells, encountered by the VPL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpCurrentUAS 1.3.6.1.4.1.164.12.2.1.2.1.1.1.11
The counter associated with the number of Unavailable Seconds, encountered by the VPL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpCurrentSES 1.3.6.1.4.1.164.12.2.1.2.1.1.1.12
The counter associated with the number of Severerly Errored Seconds, encountered by the VPL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpCurrentCDC 1.3.6.1.4.1.164.12.2.1.2.1.1.1.13
Amount of cells dropped in the current 15 minute interval of the VP connection.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpCurrentTotalDiscards 1.3.6.1.4.1.164.12.2.1.2.1.1.1.14
The total number of valid ATM cells discarded by the traffic policing entity. This includes cells originally received with CLP=0 and CLP=1.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpCurrentClp0Discards 1.3.6.1.4.1.164.12.2.1.2.1.1.1.15
The total number of valid ATM cells received with CLP=0 and discarded by the traffic policing entity.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpCurrentTotalCellOuts 1.3.6.1.4.1.164.12.2.1.2.1.1.1.16
The total number of valid ATM cells transmitted by this VPL. This includes both CLP=0 and CLP=1 cells.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpCurrentClp0CellOuts 1.3.6.1.4.1.164.12.2.1.2.1.1.1.17
The total number of valid ATM cells transmitted with CLP=0 by this VPL.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpCurrentTaggedOuts 1.3.6.1.4.1.164.12.2.1.2.1.1.1.18
The total number of valid ATM cells tagged by the traffic policing entity from CLP=0 to CLP=1 and transmitted by this VPL.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpCurrentPCR 1.3.6.1.4.1.164.12.2.1.2.1.1.1.19
The maximum traffic rate encountered in the last interval of the VP connection (monitored once a second).
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpCurrentSCR 1.3.6.1.4.1.164.12.2.1.2.1.1.1.20
The average traffic rate during the last interval of the VP connection.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpCurrentMCR 1.3.6.1.4.1.164.12.2.1.2.1.1.1.21
MCR - The minimum traffic rate encountered in the last interval of the VP connection (monitored once a second).
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpCurrentShaperTotalDiscards 1.3.6.1.4.1.164.12.2.1.2.1.1.1.22
The total number of cells (CLP0 and CLP1) discarded due to congestion by the traffic shaper.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpCurrentShaperClp0Discards 1.3.6.1.4.1.164.12.2.1.2.1.1.1.23
The total number of CLP0 cells discarded due to congestion by the traffic shaper.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpCurrentShaperClp1Discards 1.3.6.1.4.1.164.12.2.1.2.1.1.1.24
The total number of CLP1 cells discarded due to congestion by the traffic shaper.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpPMCurrentTable 1.3.6.1.4.1.164.12.2.1.2.1.2
The ATM VP Current table for Performance Management.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmVpPMCurrentEntry

atmVpPMCurrentEntry 1.3.6.1.4.1.164.12.2.1.2.1.2.1
An entry in the ATM VP Current table for Performance Management.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmVpPMCurrentEntry  

atmVpPMCurrentVpi 1.3.6.1.4.1.164.12.2.1.2.1.2.1.1
The VPI of the VPL.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmVpPMCurrentDir 1.3.6.1.4.1.164.12.2.1.2.1.2.1.2
The direction of performance management.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER forward(2), backward(3)  

atmVpPMCurrentTxClp01 1.3.6.1.4.1.164.12.2.1.2.1.2.1.3
The counter associated with the number of transmitted CLP 0+1 cells, encountered by the VPL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpPMCurrentTxClp0 1.3.6.1.4.1.164.12.2.1.2.1.2.1.4
The counter associated with the number of transmitted CLP 0 cells, encountered by the VPL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpPMCurrentRxClp01 1.3.6.1.4.1.164.12.2.1.2.1.2.1.5
The counter associated with the number of received CLP 0+1 cells, encountered by the VPL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpPMCurrentRxClp0 1.3.6.1.4.1.164.12.2.1.2.1.2.1.6
The counter associated with the number of received CLP 0 cells, encountered by the VPL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpPMCurrentErroredCells 1.3.6.1.4.1.164.12.2.1.2.1.2.1.7
The counter associated with the number of errored cells, encountered by the VPL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpPMCurrentLostCells 1.3.6.1.4.1.164.12.2.1.2.1.2.1.8
The counter associated with the number of lost cells, encountered by the VPL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpPMCurrentMisinsertedCells 1.3.6.1.4.1.164.12.2.1.2.1.2.1.9
The counter associated with the number of misinserted cells, encountered by the VPL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpPMCurrentECB 1.3.6.1.4.1.164.12.2.1.2.1.2.1.10
The counter associated with the number of ECB, encountered by the VPL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpPMCurrentSECB 1.3.6.1.4.1.164.12.2.1.2.1.2.1.11
The counter associated with the number of SECB, encountered by the VPL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpPMCurrentES 1.3.6.1.4.1.164.12.2.1.2.1.2.1.12
The counter associated with the number of Errored Seconds, encountered by the VPL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpPMCurrentSES 1.3.6.1.4.1.164.12.2.1.2.1.2.1.13
The counter associated with the number of Severely Errored Seconds, encountered by the VPL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpPMCurrentUAS 1.3.6.1.4.1.164.12.2.1.2.1.2.1.14
The counter associated with the number of Unavailable Seconds, encountered by the VPL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpPMCurrentIntervalQuality 1.3.6.1.4.1.164.12.2.1.2.1.2.1.15
If the number of errors per interval is superior to the atmNteUPLTCR value, the quality of service of the interval is declared as unacceptable.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(2), unacceptable(3)  

atmVpPMCurrentLastDayQuality 1.3.6.1.4.1.164.12.2.1.2.1.2.1.16
If the number of errors per 24 hours is superior to the atmNteDPLTCR value, the quality of service of the day is declared as degraded.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(2), degraded(4)  

atmVpIntervalTable 1.3.6.1.4.1.164.12.2.1.2.1.3
The ATM Vp Interval table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmVpIntervalEntry

atmVpIntervalEntry 1.3.6.1.4.1.164.12.2.1.2.1.3.1
An entry in the ATM Vp Interval table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmVpIntervalEntry  

atmVpIntervalVpi 1.3.6.1.4.1.164.12.2.1.2.1.3.1.1
The VPI of the VPL.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmVpIntervalNumber 1.3.6.1.4.1.164.12.2.1.2.1.3.1.2
A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..96  

atmVpIntervalRxCellsClp01 1.3.6.1.4.1.164.12.2.1.2.1.3.1.3
The counter associated with the number of transmitted cells , encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpIntervalRxCellsClp0 1.3.6.1.4.1.164.12.2.1.2.1.3.1.4
The counter associated with the number of received cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpIntervalGcra0Violations 1.3.6.1.4.1.164.12.2.1.2.1.3.1.5
The counter associated with the number of cells violating GCRA0, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpIntervalGcra1Violations 1.3.6.1.4.1.164.12.2.1.2.1.3.1.6
The counter associated with the number of cells violating GCRA1, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpIntervalRxAIS 1.3.6.1.4.1.164.12.2.1.2.1.3.1.7
The counter associated with the number of received AIS cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpIntervalTxAIS 1.3.6.1.4.1.164.12.2.1.2.1.3.1.8
The counter associated with the number of transmitted AIS cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals. Not supported in the first phase.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpIntervalRxRDI 1.3.6.1.4.1.164.12.2.1.2.1.3.1.9
The counter associated with the number of received RDI cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpIntervalTxRDI 1.3.6.1.4.1.164.12.2.1.2.1.3.1.10
The counter associated with the number of transmitted RDI cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpIntervalContinuityLoss 1.3.6.1.4.1.164.12.2.1.2.1.3.1.11
The counter associated with the number of Continuity Loss cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpIntervalUAS 1.3.6.1.4.1.164.12.2.1.2.1.3.1.12
The counter associated with the number of Unavailable Seconds, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpIntervalSES 1.3.6.1.4.1.164.12.2.1.2.1.3.1.13
The counter associated with the number of Severerly Errored Seconds, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpIntervalCDC 1.3.6.1.4.1.164.12.2.1.2.1.3.1.14
Amount of cells dropped in the 15 minute interval of the VP connection.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpIntervalTotalDiscards 1.3.6.1.4.1.164.12.2.1.2.1.3.1.15
The total number of valid ATM cells discarded by the traffic policing entity. This includes cells originally received with CLP=0 and CLP=1.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpIntervalClp0Discards 1.3.6.1.4.1.164.12.2.1.2.1.3.1.16
The total number of valid ATM cells received with CLP=0 an discarded by the traffic policing entity.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpIntervalTotalCellOuts 1.3.6.1.4.1.164.12.2.1.2.1.3.1.17
The total number of valid ATM cells transmitted by this VPL. This includes both CLP=0 and CLP=1 cells.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpIntervalClp0CellOuts 1.3.6.1.4.1.164.12.2.1.2.1.3.1.18
The total number of valid ATM cells transmitted with CLP=0 by this VPL.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpIntervalTaggedOuts 1.3.6.1.4.1.164.12.2.1.2.1.3.1.19
The total number of valid ATM cells tagged by the traffic policing entity from CLP=0 to CLP=1 and transmitted by this VPL.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpIntervalPCR 1.3.6.1.4.1.164.12.2.1.2.1.3.1.20
The maximum traffic rate encountered in the last interval of the VP connection (monitored once a second) encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpIntervalSCR 1.3.6.1.4.1.164.12.2.1.2.1.3.1.21
The average traffic rate during the last interval of the VP connection , encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpIntervalMCR 1.3.6.1.4.1.164.12.2.1.2.1.3.1.22
MCR - The minimum traffic rate encountered in the last interval of the VP connection (monitored once a second) encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpIntervalShaperTotalDiscards 1.3.6.1.4.1.164.12.2.1.2.1.3.1.23
The total number of cells (CLP0 and CLP1) discarded due to congestion by the traffic shaper.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpIntervalShaperClp0Discards 1.3.6.1.4.1.164.12.2.1.2.1.3.1.24
The total number of CLP0 cells discarded due to congestion by the traffic shaper.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpIntervalShaperClp1Discards 1.3.6.1.4.1.164.12.2.1.2.1.3.1.25
The total number of CLP1 cells discarded due to congestion by the traffic shaper.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpPMIntervalTable 1.3.6.1.4.1.164.12.2.1.2.1.4
The ATM Vp Interval table for Performance Management.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmVpPMIntervalEntry

atmVpPMIntervalEntry 1.3.6.1.4.1.164.12.2.1.2.1.4.1
An entry in the ATM Vp Interval table for Performance Management.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmVpPMIntervalEntry  

atmVpPMIntervalVpi 1.3.6.1.4.1.164.12.2.1.2.1.4.1.1
The VPI of the VPL.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmVpPMIntervalDir 1.3.6.1.4.1.164.12.2.1.2.1.4.1.2
The direction of performance management.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER forward(2), backward(3)  

atmVpPMIntervalNumber 1.3.6.1.4.1.164.12.2.1.2.1.4.1.3
A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..96  

atmVpPMIntervalTxClp01 1.3.6.1.4.1.164.12.2.1.2.1.4.1.4
The counter associated with the number of transmitted CLP 0+1 cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpPMIntervalTxClp0 1.3.6.1.4.1.164.12.2.1.2.1.4.1.5
The counter associated with the number of transmitted CLP 0 cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpPMIntervalRxClp01 1.3.6.1.4.1.164.12.2.1.2.1.4.1.6
The counter associated with the number of received CLP 0+1 cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpPMIntervalRxClp0 1.3.6.1.4.1.164.12.2.1.2.1.4.1.7
The counter associated with the number of received CLP 0 cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpPMIntervalErroredCells 1.3.6.1.4.1.164.12.2.1.2.1.4.1.8
The counter associated with the number of Errored cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpPMIntervalLostCells 1.3.6.1.4.1.164.12.2.1.2.1.4.1.9
The counter associated with the number of Lost cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpPMIntervalMisinsertedCells 1.3.6.1.4.1.164.12.2.1.2.1.4.1.10
The counter associated with the number of Misinserted cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpPMIntervalECB 1.3.6.1.4.1.164.12.2.1.2.1.4.1.11
The counter associated with the number of ECBs encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpPMIntervalSECB 1.3.6.1.4.1.164.12.2.1.2.1.4.1.12
The counter associated with the number of SECBs encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpPMIntervalES 1.3.6.1.4.1.164.12.2.1.2.1.4.1.13
The counter associated with the number of Errored Seconds, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpPMIntervalSES 1.3.6.1.4.1.164.12.2.1.2.1.4.1.14
The counter associated with the number of Severely Errored Seconds, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpPMIntervalUAS 1.3.6.1.4.1.164.12.2.1.2.1.4.1.15
The counter associated with the number of Unavailable Seconds, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpPMIntervalQuality 1.3.6.1.4.1.164.12.2.1.2.1.4.1.16
If the number of errors per interval is superior to the atmNteUPLTCR value, the quality of service of the interval is declared as unacceptable.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(2), unacceptable(3)  

atmVpPMIntervalLastDayQuality 1.3.6.1.4.1.164.12.2.1.2.1.4.1.17
If the number of errors per 24 hours is superior to the atmNteDPLTCR value, the quality of service of the day is declared as degraded.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(2), degraded(4)  

atmVpQoSTable 1.3.6.1.4.1.164.12.2.1.2.1.5
The VP QoS table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmVpQoSEntry

atmVpQoSEntry 1.3.6.1.4.1.164.12.2.1.2.1.5.1
.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmVpQoSEntry  

atmVpQoSPeriodRef 1.3.6.1.4.1.164.12.2.1.2.1.5.1.1
This object is an index that specifies which period of time, the next 2 objects refer to. currentPeriod - the period since last systemResetAllStatsCmd received or since Start-up (if no systemResetAllStatsCmd was received since Start-up) until now. lastPeriod - the period between last two commands of systemResetAllStatsCmd. - If only one command occurred since Start-up: the period between Start-up and last command. - If no command occurred since Start-up: this period will not actually exist. In this case, he following 5 objects will be 0.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER currentPeriod(1), lastPeriod(2)  

atmVpQoSElapsedTime 1.3.6.1.4.1.164.12.2.1.2.1.5.1.2
Elapsed Time in seconds. - for atmVpQoSPeriodRef = currentPeriod: The period since last systemResetAllStatsCmd received or since Start-up (if no systemResetAllStatsCmd was received since Start-up) until now. - for atmVpQoSPeriodRef = lastPeriod: The value of atmVpQoSElapsedTime when last systemResetAllStatsCmd was received.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmVpQoSUAS 1.3.6.1.4.1.164.12.2.1.2.1.5.1.3
Number of Unavailable Seconds for the reference period (atmVpQoSPeriodRef).
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpPMQoSTable 1.3.6.1.4.1.164.12.2.1.2.1.6
The PM VP QoS table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmVpPMQoSEntry

atmVpPMQoSEntry 1.3.6.1.4.1.164.12.2.1.2.1.6.1
.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmVpPMQoSEntry  

atmVpPMQoSDirection 1.3.6.1.4.1.164.12.2.1.2.1.6.1.1
The direction of performance management.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER forward(2), backward(3)  

atmVpPMQoSPeriodRef 1.3.6.1.4.1.164.12.2.1.2.1.6.1.2
This object is an index that specifies which period of time, the next 5 objects refer to. currentPeriod - the period since last systemResetAllStatsCmd received or since Start-up (if no systemResetAllStatsCmd was received since Start-up) until now. lastPeriod - the period between last two commands of systemResetAllStatsCmd. - If only one command occurred since Start-up: the period between Start-up and last command. - If no command occurred since Start-up: this period will not actually exist. In this case, he following 5 objects will be 0.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER currentPeriod(1), lastPeriod(2)  

atmVpPMQoSCLR 1.3.6.1.4.1.164.12.2.1.2.1.6.1.3
Cell Loss Ratio counter for the reference period (atmVpPMQoSPeriodRef)- defined in accordance with I.356 , in %. The value will be multipuled by 100.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpPMQoSCER 1.3.6.1.4.1.164.12.2.1.2.1.6.1.4
Cell Error Ratio counter for the reference period (atmVpPMQoSPeriodRef) defined in accordance with I.356 , in %. The value will be multipuled by 100.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpPMQoSCMR 1.3.6.1.4.1.164.12.2.1.2.1.6.1.5
Cell Misinsertion Ratio counter for the reference period (atmVpPMQoSPeriodRef) defined in accordance with I.356 , cells/sec .
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpShaperStatTable 1.3.6.1.4.1.164.12.2.1.2.1.7
The ATM VP shaper statistics table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmVpShaperStatEntry

atmVpShaperStatEntry 1.3.6.1.4.1.164.12.2.1.2.1.7.1
An entry in the ATM VP shaper statistics table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmVpShaperStatEntry  

atmVpShaperDiscarded 1.3.6.1.4.1.164.12.2.1.2.1.7.1.1
The number of Cells that were discarded in the shaper on that VPC due to buffer overflow. This counter counts till it reaches its MAX value (20 bits) and then rolls over.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

atmVpShaperOccupation 1.3.6.1.4.1.164.12.2.1.2.1.7.1.2
The number of Cells that are currently stored in the buffer. This parameter is limited to 20 bits.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmVpShaperMaxOccupation 1.3.6.1.4.1.164.12.2.1.2.1.7.1.3
The Maximum number of Cells that were stored in the buffer, since this VP was activated. This parameter is limited to 20 bits.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmVpShaperLevel 1.3.6.1.4.1.164.12.2.1.2.1.7.1.4
The occupation of the buffer according to a predefined threshold. empty - buffer is Empty full - buffer is Full below - buffer is Below the threshold above - buffer is Above the threshold. This is also the trigger to start EPD\PPD mechanism, if set for the VPC.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER empty(1), full(2), below(3), above(4)  

atmVpShaperEpdDropped 1.3.6.1.4.1.164.12.2.1.2.1.7.1.5
The number of Cells that were dropped in the shaper on that VPC due to EPD\PPD mechanism in the last second. This parameter is limited to 24 bits. Applicable for a EPD/PPD VP only.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

atmVpShaperTotalEpdDropped 1.3.6.1.4.1.164.12.2.1.2.1.7.1.6
The Total number of Cells that were dropped in the shaper on that VPC due to EPD\PPD mechanism in the last 15 minutes. This counter automatically reset itself every 15 minutes. Applicable for a EPD/PPD VP only.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

atmVcPerformance 1.3.6.1.4.1.164.12.2.1.2.2
OBJECT IDENTIFIER    

atmVcCurrentTable 1.3.6.1.4.1.164.12.2.1.2.2.1
The ATM VC Current table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmVcCurrentEntry

atmVcCurrentEntry 1.3.6.1.4.1.164.12.2.1.2.2.1.1
An entry in the ATM VC Current table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmVcCurrentEntry  

atmVcCurrentVpi 1.3.6.1.4.1.164.12.2.1.2.2.1.1.1
The VPI of the VCL.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmVcCurrentVci 1.3.6.1.4.1.164.12.2.1.2.2.1.1.2
The VCI of the VCL.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmVcCurrentRxCellsClp01 1.3.6.1.4.1.164.12.2.1.2.2.1.1.3
The counter associated with the number of transmitted cells, encountered by the VCL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcCurrentRxCellsClp0 1.3.6.1.4.1.164.12.2.1.2.2.1.1.4
The counter associated with the number of received cells, encountered by the VCL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcCurrentGcra0Violations 1.3.6.1.4.1.164.12.2.1.2.2.1.1.5
The counter associated with the number of cells violating GCRA0, encountered by the VCL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcCurrentGcra1Violations 1.3.6.1.4.1.164.12.2.1.2.2.1.1.6
The counter associated with the number of cells violating GCRA1, encountered by the VCL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcCurrentRxAIS 1.3.6.1.4.1.164.12.2.1.2.2.1.1.7
The counter associated with the number of received AIS cells, encountered by the VCL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcCurrentTxAIS 1.3.6.1.4.1.164.12.2.1.2.2.1.1.8
The counter associated with the number of transmitted AIS cells, encountered by the VCL of this ATM interface in the current 15 minute interval. Not Supported in the first phase.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcCurrentRxRDI 1.3.6.1.4.1.164.12.2.1.2.2.1.1.9
The counter associated with the number of received RDI cells, encountered by the VCL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcCurrentTxRDI 1.3.6.1.4.1.164.12.2.1.2.2.1.1.10
The counter associated with the number of transmitted RDI cells, encountered by the VCL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcCurrentContinuityLoss 1.3.6.1.4.1.164.12.2.1.2.2.1.1.11
The counter associated with the number of loss of continuity cells, encountered by the VCL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcCurrentUAS 1.3.6.1.4.1.164.12.2.1.2.2.1.1.12
The counter associated with the number of Unavailable Seconds, encountered by the VCL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcCurrentSES 1.3.6.1.4.1.164.12.2.1.2.2.1.1.13
The counter associated with the number of Severerly Errored Seconds, encountered by the VCL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcCurrentCDC 1.3.6.1.4.1.164.12.2.1.2.2.1.1.14
Amount of cells dropped in the current 15 minute interval of the VC connection.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcCurrentTotalDiscards 1.3.6.1.4.1.164.12.2.1.2.2.1.1.15
The total number of valid ATM cells discarded by the traffic policing entity. This includes cells originally received with CLP=0 and CLP=1.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcCurrentClp0Discards 1.3.6.1.4.1.164.12.2.1.2.2.1.1.16
The total number of valid ATM cells received with CLP=0 an discarded by the traffic policing entity.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcCurrentTotalCellOuts 1.3.6.1.4.1.164.12.2.1.2.2.1.1.17
The total number of valid ATM cells transmitted by this VPL. This includes both CLP=0 and CLP=1 cells.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcCurrentClp0CellOuts 1.3.6.1.4.1.164.12.2.1.2.2.1.1.18
The total number of valid ATM cells transmitted with CLP=0 by this VPL.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcCurrentTaggedOuts 1.3.6.1.4.1.164.12.2.1.2.2.1.1.19
The total number of valid ATM cells tagged by the traffic policing entity from CLP=0 to CLP=1 and transmitted by this VPL.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcCurrentPCR 1.3.6.1.4.1.164.12.2.1.2.2.1.1.20
The maximum traffic rate encountered in the last interval of the VC connection (monitored once a second).
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcCurrentSCR 1.3.6.1.4.1.164.12.2.1.2.2.1.1.21
The average traffic rate during the last interval of the VC connection.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcCurrentMCR 1.3.6.1.4.1.164.12.2.1.2.2.1.1.22
MCR - The minimum traffic rate encountered in the last interval of the VC connection (monitored once a second).
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcCurrentShaperTotalDiscards 1.3.6.1.4.1.164.12.2.1.2.2.1.1.23
The total number of cells (CLP0 and CLP1) discarded due to congestion by the traffic shaper.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcCurrentShaperClp0Discards 1.3.6.1.4.1.164.12.2.1.2.2.1.1.24
The total number of CLP0 cells discarded due to congestion by the traffic shaper.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcCurrentShaperClp1Discards 1.3.6.1.4.1.164.12.2.1.2.2.1.1.25
The total number of CLP1 cells discarded due to congestion by the traffic shaper.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcPMCurrentTable 1.3.6.1.4.1.164.12.2.1.2.2.2
The ATM VC Current table for Performance Management.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmVcPMCurrentEntry

atmVcPMCurrentEntry 1.3.6.1.4.1.164.12.2.1.2.2.2.1
An entry in the ATM VC Current table for Performance Management.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmVcPMCurrentEntry  

atmVcPMCurrentVpi 1.3.6.1.4.1.164.12.2.1.2.2.2.1.1
The VPI of the VCL.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmVcPMCurrentVci 1.3.6.1.4.1.164.12.2.1.2.2.2.1.2
The VCI of the VCL.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmVcPMCurrentDir 1.3.6.1.4.1.164.12.2.1.2.2.2.1.3
The direction of Performance Management.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmVcPMCurrentTxClp01 1.3.6.1.4.1.164.12.2.1.2.2.2.1.4
The counter associated with the number of transmitted CLP 0+1 cells, encountered by the VCL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcPMCurrentTxClp0 1.3.6.1.4.1.164.12.2.1.2.2.2.1.5
The counter associated with the number of transmitted CLP 0 cells, encountered by the VCL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcPMCurrentRxClp01 1.3.6.1.4.1.164.12.2.1.2.2.2.1.6
The counter associated with the number of received CLP 0+1 cells, encountered by the VCL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcPMCurrentRxClp0 1.3.6.1.4.1.164.12.2.1.2.2.2.1.7
The counter associated with the number of received CLP 0 cells, encountered by the VCL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcPMCurrentErroredCells 1.3.6.1.4.1.164.12.2.1.2.2.2.1.8
The counter associated with the number of errored cells, encountered by the VCL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcPMCurrentLostCells 1.3.6.1.4.1.164.12.2.1.2.2.2.1.9
The counter associated with the number of lost cells, encountered by the VCL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcPMCurrentMisinsertedCells 1.3.6.1.4.1.164.12.2.1.2.2.2.1.10
The counter associated with the number of misinserted cells, encountered by the VCL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcPMCurrentECB 1.3.6.1.4.1.164.12.2.1.2.2.2.1.11
The counter associated with the number of ECBs encountered by the VCL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcPMCurrentSECB 1.3.6.1.4.1.164.12.2.1.2.2.2.1.12
The counter associated with the number of SECBs encountered by the VCL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcPMCurrentES 1.3.6.1.4.1.164.12.2.1.2.2.2.1.13
The counter associated with the number of Errored Seconds, encountered by the VCL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcPMCurrentSES 1.3.6.1.4.1.164.12.2.1.2.2.2.1.14
The counter associated with the number of Severely Errored Seconds, encountered by the VCL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcPMCurrentUAS 1.3.6.1.4.1.164.12.2.1.2.2.2.1.15
The counter associated with the number of Severely Errored Seconds, encountered by the VCL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcPMCurrentIntervalQuality 1.3.6.1.4.1.164.12.2.1.2.2.2.1.16
If the number of errors per interval is superior to the atmNteUPLTCR value, the quality of service of the interval is declared as unacceptable.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(2), unacceptable(3)  

atmVcPMCurrentLastDayQuality 1.3.6.1.4.1.164.12.2.1.2.2.2.1.17
If the number of errors per 24 hours is superior to the atmNteDPLTCR value, the quality of service of the day is declared as degraded.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(2), degraded(4)  

atmVcIntervalTable 1.3.6.1.4.1.164.12.2.1.2.2.3
The ATM Vc Interval table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmVcIntervalEntry

atmVcIntervalEntry 1.3.6.1.4.1.164.12.2.1.2.2.3.1
An entry in the ATM Vc Interval table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmVcIntervalEntry  

atmVcIntervalVpi 1.3.6.1.4.1.164.12.2.1.2.2.3.1.1
The VPI of the VCL.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmVcIntervalVci 1.3.6.1.4.1.164.12.2.1.2.2.3.1.2
The VCI of the VCL.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmVcIntervalNumber 1.3.6.1.4.1.164.12.2.1.2.2.3.1.3
A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..96  

atmVcIntervalRxCellsClp01 1.3.6.1.4.1.164.12.2.1.2.2.3.1.4
The counter associated with the number of transmitted cells , encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcIntervalRxCellsClp0 1.3.6.1.4.1.164.12.2.1.2.2.3.1.5
The counter associated with the number of received cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcIntervalGcra0Violations 1.3.6.1.4.1.164.12.2.1.2.2.3.1.6
The counter associated with the number of cells violating GCRA0, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcIntervalGcra1Violations 1.3.6.1.4.1.164.12.2.1.2.2.3.1.7
The counter associated with the number of cells violating GCRA1, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcIntervalRxAIS 1.3.6.1.4.1.164.12.2.1.2.2.3.1.8
The counter associated with the number of received AIS cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcIntervalTxAIS 1.3.6.1.4.1.164.12.2.1.2.2.3.1.9
The counter associated with the number of transmitted AIS cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals. Not supported in the first phase.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcIntervalRxRDI 1.3.6.1.4.1.164.12.2.1.2.2.3.1.10
The counter associated with the number of received RDI cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcIntervalTxRDI 1.3.6.1.4.1.164.12.2.1.2.2.3.1.11
The counter associated with the number of transmitted RDI cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcIntervalContinuityLoss 1.3.6.1.4.1.164.12.2.1.2.2.3.1.12
The counter associated with the number of Continuity Loss cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcIntervalUAS 1.3.6.1.4.1.164.12.2.1.2.2.3.1.13
The counter associated with the number of Unavailable Seconds, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcIntervalSES 1.3.6.1.4.1.164.12.2.1.2.2.3.1.14
The counter associated with the number of Severerly Errored Seconds, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcIntervalCDC 1.3.6.1.4.1.164.12.2.1.2.2.3.1.15
Amount of cells dropped in the 15 minute interval of the VC connection.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcIntervalTotalDiscards 1.3.6.1.4.1.164.12.2.1.2.2.3.1.16
The total number of valid ATM cells discarded by the traffic policing entity. This includes cells originally received with CLP=0 and CLP=1.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcIntervalClp0Discards 1.3.6.1.4.1.164.12.2.1.2.2.3.1.17
The total number of valid ATM cells received with CLP=0 an discarded by the traffic policing entity.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcIntervalTotalCellOuts 1.3.6.1.4.1.164.12.2.1.2.2.3.1.18
The total number of valid ATM cells transmitted by this VPL. This includes both CLP=0 and CLP=1 cells.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcIntervalClp0CellOuts 1.3.6.1.4.1.164.12.2.1.2.2.3.1.19
The total number of valid ATM cells transmitted with CLP=0 by this VPL.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcIntervalTaggedOuts 1.3.6.1.4.1.164.12.2.1.2.2.3.1.20
The total number of valid ATM cells tagged by the traffic policing entity from CLP=0 to CLP=1 and transmitted by this VPL.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcIntervalPCR 1.3.6.1.4.1.164.12.2.1.2.2.3.1.21
The maximum traffic rate encountered in the last interval of the VC connection (monitored once a second) encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcIntervalSCR 1.3.6.1.4.1.164.12.2.1.2.2.3.1.22
The average traffic rate during the last interval of the VC connection, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcIntervalMCR 1.3.6.1.4.1.164.12.2.1.2.2.3.1.23
MCR - The minimum traffic rate encountered in the last interval of the VC connection (monitored once a second) encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcIntervalShaperTotalDiscards 1.3.6.1.4.1.164.12.2.1.2.2.3.1.24
The total number of cells (CLP0 and CLP1) discarded due to congestion by the traffic shaper.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcIntervalShaperClp0Discards 1.3.6.1.4.1.164.12.2.1.2.2.3.1.25
The total number of CLP0 cells discarded due to congestion by the traffic shaper.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcIntervalShaperClp1Discards 1.3.6.1.4.1.164.12.2.1.2.2.3.1.26
The total number of CLP1 cells discarded due to congestion by the traffic shaper.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcPMIntervalTable 1.3.6.1.4.1.164.12.2.1.2.2.4
The ATM Vc Interval table for Performance Management.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmVcPMIntervalEntry

atmVcPMIntervalEntry 1.3.6.1.4.1.164.12.2.1.2.2.4.1
An entry in the ATM Vc Interval table for Performance Management.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmVcPMIntervalEntry  

atmVcPMIntervalVpi 1.3.6.1.4.1.164.12.2.1.2.2.4.1.1
The VPI of the VCL.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmVcPMIntervalVci 1.3.6.1.4.1.164.12.2.1.2.2.4.1.2
The VCI of the VCL.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmVcPMIntervalDir 1.3.6.1.4.1.164.12.2.1.2.2.4.1.3
The direction of Performance Management.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER forward(2), backward(3)  

atmVcPMIntervalNumber 1.3.6.1.4.1.164.12.2.1.2.2.4.1.4
A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..96  

atmVcPMIntervalTxClp01 1.3.6.1.4.1.164.12.2.1.2.2.4.1.5
The counter associated with the number of transmitted CLP 0+1 cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcPMIntervalTxClp0 1.3.6.1.4.1.164.12.2.1.2.2.4.1.6
The counter associated with the number of transmitted CLP 0 cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcPMIntervalRxClp01 1.3.6.1.4.1.164.12.2.1.2.2.4.1.7
The counter associated with the number of received CLP 0+1 cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcPMIntervalRxClp0 1.3.6.1.4.1.164.12.2.1.2.2.4.1.8
The counter associated with the number of received CLP 0 cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcPMIntervalErroredCells 1.3.6.1.4.1.164.12.2.1.2.2.4.1.9
The counter associated with the number of Errored cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcPMIntervalLostCells 1.3.6.1.4.1.164.12.2.1.2.2.4.1.10
The counter associated with the number of Lost cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcPMIntervalMisinsertedCells 1.3.6.1.4.1.164.12.2.1.2.2.4.1.11
The counter associated with the number of Misinserted cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcPMIntervalECB 1.3.6.1.4.1.164.12.2.1.2.2.4.1.12
The counter associated with the number of ECBs encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcPMIntervalSECB 1.3.6.1.4.1.164.12.2.1.2.2.4.1.13
The counter associated with the number of SECBs encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcPMIntervalES 1.3.6.1.4.1.164.12.2.1.2.2.4.1.14
The counter associated with the number of Errored Seconds, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcPMIntervalSES 1.3.6.1.4.1.164.12.2.1.2.2.4.1.15
The counter associated with the number of Severely Errored Seconds, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcPMIntervalUAS 1.3.6.1.4.1.164.12.2.1.2.2.4.1.16
The counter associated with the number of Unavailable Seconds, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcPMIntervalQuality 1.3.6.1.4.1.164.12.2.1.2.2.4.1.17
If the number of errors per interval is superior to the atmNteUPLTCR value, the quality of service of the interval is declared as unacceptable.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(2), unacceptable(3)  

atmVcPMIntervalLastDayQuality 1.3.6.1.4.1.164.12.2.1.2.2.4.1.18
If the number of errors per 24 hours is superior to the atmNteDPLTCR value, the quality of service of the day is declared as degraded.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(2), degraded(4)  

atmVcQoSTable 1.3.6.1.4.1.164.12.2.1.2.2.6
The ATM VP QoS table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmVcQoSEntry

atmVcQoSEntry 1.3.6.1.4.1.164.12.2.1.2.2.6.1
An entry in the ATM VP table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmVcQoSEntry  

atmVcQoSPeriodRef 1.3.6.1.4.1.164.12.2.1.2.2.6.1.1
This object is an index that specifies which period of time, the next 2 objects refer to. currentPeriod - the period since last systemResetAllStatsCmd received or since Start-up (if no systemResetAllStatsCmd was received since Start-up) until now. lastPeriod - the period between last two commands of systemResetAllStatsCmd. - If only one command occurred since Start-up: the period between Start-up and last command. - If no command occurred since Start-up: this period will not actually exist. In this case, he following 5 objects will be 0.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER currentPeriod(1), lastPeriod(2)  

atmVcQoSElapsedTime 1.3.6.1.4.1.164.12.2.1.2.2.6.1.2
Elapsed Time in seconds. - for atmVcQoSPeriodRef = currentPeriod: The period since last systemResetAllStatsCmd received or since Start-up (if no systemResetAllStatsCmd was received since Start-up) until now. - for atmVcQoSPeriodRef = lastPeriod: The value of atmVcQoSElapsedTime when last systemResetAllStatsCmd was received.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmVcQoSUAS 1.3.6.1.4.1.164.12.2.1.2.2.6.1.3
Number of Unavailable Seconds for the reference period (atmVcQoSPeriodRef).
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcPMQoSTable 1.3.6.1.4.1.164.12.2.1.2.2.7
The PM VC QoS table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmVcPMQoSEntry

atmVcPMQoSEntry 1.3.6.1.4.1.164.12.2.1.2.2.7.1
An entry in the VC PM QoS table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmVcPMQoSEntry  

atmVcPMQoSDirection 1.3.6.1.4.1.164.12.2.1.2.2.7.1.1
The direction of performance management.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER forward(2), backward(3)  

atmVcPMQoSPeriodRef 1.3.6.1.4.1.164.12.2.1.2.2.7.1.2
This object is an index that specifies which period of time, the next 5 objects refer to. currentPeriod - the period since last systemResetAllStatsCmd received or since Start-up (if no systemResetAllStatsCmd was received since Start-up) until now. lastPeriod - the period between last two commands of systemResetAllStatsCmd. - If only one command occurred since Start-up: the period between Start-up and last command. - If no command occurred since Start-up: this period will not actually exist. In this case, he following 5 objects will be 0.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER currentPeriod(1), lastPeriod(2)  

atmVcPMQoSCLR 1.3.6.1.4.1.164.12.2.1.2.2.7.1.3
Cell Loss Ratio counter for the reference period (atmVcPMQoSPeriodRef)- defined in accordance with I.356 , in %. The value will be multipuled by 100.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcPMQoSCER 1.3.6.1.4.1.164.12.2.1.2.2.7.1.4
Cell Error Ratio counter for the reference period (atmVcPMQoSPeriodRef) defined in accordance with I.356 , in %. The value will be multipuled by 100.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcPMQoSCMR 1.3.6.1.4.1.164.12.2.1.2.2.7.1.5
Cell Miss-insertion Ratio counter for the reference period (atmVcPMQoSPeriodRef) defined in accordance with I.356 , cells/sec .
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcShaperStatTable 1.3.6.1.4.1.164.12.2.1.2.2.8
The ATM VC shaper statistics table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmVcShaperStatEntry

atmVcShaperStatEntry 1.3.6.1.4.1.164.12.2.1.2.2.8.1
An entry in the ATM VC shaper statistics table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmVcShaperStatEntry  

atmVcShaperDiscarded 1.3.6.1.4.1.164.12.2.1.2.2.8.1.1
The number of Cells that were discarded in the shaper on that VCC due to buffer overflow. This counter counts till it reaches its MAX value (20 bits) and then rolls over.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

atmVcShaperOccupation 1.3.6.1.4.1.164.12.2.1.2.2.8.1.2
The number of Cells that are currently stored in the buffer. This parameter is limited to 20 bits.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmVcShaperMaxOccupation 1.3.6.1.4.1.164.12.2.1.2.2.8.1.3
The Maximum number of Cells that were stored in the buffer, since this VC was activated. This parameter is limited to 20 bits.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmVcShaperLevel 1.3.6.1.4.1.164.12.2.1.2.2.8.1.4
The occupation of the buffer according to a predefined threshold. empty - buffer is Empty full - buffer is Full below - buffer is Below the threshold above - buffer is Above the threshold. This is also the trigger to start EPD\PPD mechanism, if set for the VCC.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER empty(1), full(2), below(3), above(4)  

atmVcShaperEpdDropped 1.3.6.1.4.1.164.12.2.1.2.2.8.1.5
The number of Cells that were dropped in the shaper on that VCC due to EPD\PPD mechanism in the last second. This parameter is limited to 24 bits. Applicable for a EPD/PPD VC only.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

atmVcShaperTotalEpdDropped 1.3.6.1.4.1.164.12.2.1.2.2.8.1.6
The Total number of Cells that were dropped in the shaper on that VPC due to EPD\PPD mechanism in the last 15 minutes. This counter automatically reset itself every 15 minutes. Applicable for a EPD/PPD VC only.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

atmIntervalDateTable 1.3.6.1.4.1.164.12.2.1.3
The agent will keep in this group the date & time corresponding to each interval.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmIntervalDateEntry

atmIntervalDateEntry 1.3.6.1.4.1.164.12.2.1.3.1
The date & time for the given interval.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmIntervalDateEntry  

atmIntervalDateInterval 1.3.6.1.4.1.164.12.2.1.3.1.1
The interval number defining this entry.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..96  

atmIntervalDateDate 1.3.6.1.4.1.164.12.2.1.3.1.2
The date corresponding to this interval.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

atmIntervalDateTime 1.3.6.1.4.1.164.12.2.1.3.1.3
The time corresponding to this interval.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

atmNteSys 1.3.6.1.4.1.164.12.3.1
OBJECT IDENTIFIER    

atmNteSysConfig 1.3.6.1.4.1.164.12.3.1.1
OBJECT IDENTIFIER    

atmNteManagerTable 1.3.6.1.4.1.164.12.3.1.1.1
The Manager Table includes all the NMSs that receive traps from this agent. A single manager can receive traps on more than one PVC. The agent will set implicitly the correct ifIndex, VPI, VCI values to all relevant entries in the table when the user changes them for one of the PVCs.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmNteManagerEntry

atmNteManagerEntry 1.3.6.1.4.1.164.12.3.1.1.1.1
A single manager and the PVC for receiving traps.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmNteManagerEntry  

atmNteManagerIP 1.3.6.1.4.1.164.12.3.1.1.1.1.1
The IP address of the NMS.
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

atmNteManagerPvc 1.3.6.1.4.1.164.12.3.1.1.1.1.2
A PVC index. The range is 1..8. There are four PVCs on the User Port and four PVCs on the Network Port. The default VPI, VCI values are specified below.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmNteManagerIfIndex 1.3.6.1.4.1.164.12.3.1.1.1.1.3
The ATM interface index of the management port.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

atmNteManagerVpi 1.3.6.1.4.1.164.12.3.1.1.1.1.4
The VPI of the management VCL. Default: 0.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

atmNteManagerVci 1.3.6.1.4.1.164.12.3.1.1.1.1.5
The VCI of the management VCL. Defaults: 32,33,34,35.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

atmNteManagerTrapMask 1.3.6.1.4.1.164.12.3.1.1.1.1.6
The value of this attribute determines the type of traps the agent should mask and not send to this NMS. The value is differently determined for different products. There are mainly two methods: - an integer number, specifying the traps' severity. - a sum of 2**n, where n is a bit assigned to a certain masked trap group. User should consult the product specification, to find out the method employed.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

atmNteManagerRowStatus 1.3.6.1.4.1.164.12.3.1.1.1.1.7
Creation/Deletion of rows in the table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

atmNteManagerNextHop 1.3.6.1.4.1.164.12.3.1.1.1.1.8
This parameter is relevant to Ethernet out of band host only (PVC=10). The Next Hop IP address of the entry route.
Status: current Access: read-create
OBJECT-TYPE    
  IpAddress  

atmNteManagerVlanSupport 1.3.6.1.4.1.164.12.3.1.1.1.1.9
VLAN support (Tagging). no - No support to VLAN. yes - 4 VLAN bytes will be added to the frame.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

atmNteManagerVlanIdentifier 1.3.6.1.4.1.164.12.3.1.1.1.1.10
VLAN ID. Range is 0..4095.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

atmNteManagerVlanFramePriority 1.3.6.1.4.1.164.12.3.1.1.1.1.11
VLAN Frame priority.Range is 0..7.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

atmNteManagerAlarmTrapMask 1.3.6.1.4.1.164.12.3.1.1.1.1.12
The value of this object determines the alarm traps that the agent should mask and not send to this NMS. The value is an Octet String, where each bit is assigned to a certain trap. If the bit = 1, the trap will be masked. If the bit = 0, the trap will not be masked. More details on the masked traps exist in the product specification. For products that do not mask specific traps, the value of the bits will be 0.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING  

atmNteManagerConfigPorts 1.3.6.1.4.1.164.12.3.1.1.1.1.13
This variable defines from which port/s this manager can configure the device. For IPmux 11 the value of this variable will be according to the ports combination: Network =1 User1=2 User2=4 (For Example: All ports = 7).
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

atmNteUPLTCR 1.3.6.1.4.1.164.12.3.1.1.2
The Unacceptable ES Limit threshold for Performance Management.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmNteDPLTCR 1.3.6.1.4.1.164.12.3.1.1.3
The Degraded ES Limit threshold for Performance Management.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmNteSysLogClearAll 1.3.6.1.4.1.164.12.3.1.1.4
Setting the variable to clear(3) removes all entries in the Log Buffer of the agent. The agent will immediately reset the variable to off(2).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), clear(3)  

atmNteUSESLTCR 1.3.6.1.4.1.164.12.3.1.1.5
The Unacceptable SES Limit threshold for Performance Management.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmNteDSESLTCR 1.3.6.1.4.1.164.12.3.1.1.6
The Degraded ES Limit threshold for Performance Management.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmNteProtection 1.3.6.1.4.1.164.12.3.1.1.8
OBJECT IDENTIFIER    

atmNteProtectionMode 1.3.6.1.4.1.164.12.3.1.1.8.1
Protection Mode. MspOn - Multiplex section protection. pathOn - High order path protection. mspUniOn - Multiplex section Uni-directional protection. mspOneToN - Multiplex section protection.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(1), mspOn(2), pathOn(3), mspUniOn(4), mspOneToN(5)  



atmNteConfOam 1.3.6.1.4.1.164.12.3.1.1.9
OBJECT IDENTIFIER    

atmNteConfOamSupport 1.3.6.1.4.1.164.12.3.1.1.9.1
OAM support mode, which determines the device location in a segment wise.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER intermediate(1), segmentTermination(2), endToEndTermination(3), vpEndToEndVcSegment(4)  

atmNteConfOamTransmission 1.3.6.1.4.1.164.12.3.1.1.9.2
OBJECT IDENTIFIER    

atmNteConfOamAIS 1.3.6.1.4.1.164.12.3.1.1.9.2.1
Defines if a F4 segment OAM cell is transmitted due to problems in the other port, i.e. physical layer alarm or F4 defect. This is valid only when the ACE101 has ATM UNI interfaces in both sides and is configured for 'Non-Intrusive' mode. none - AIS is not sent to any of the ports. user - F4 AIS will be sent toward the user when defect is detected in the network port. network - F4 AIS will be sent toward the network when defect is detected in the user port. both - F4 AIS will be sent toward the network when defect is detected in the user port and toward the user when defect is detected in the network port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), user(2), network(3), both(4)  

atmNteConfOamRDI 1.3.6.1.4.1.164.12.3.1.1.9.2.2
Defines if an F4 OAM RDI cell is transmitted due to physical layer problems in the port (in addition to F4 RDI cells transmitted due to ATM layer problems). The type of F4 RDI (Segment or End-to-End) is according to the ACE-101 OAM mode. For example, If it is enabled for Network port, then physical layer defect will initiate the transmission of F4 RDI cell back to the trunk.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), user(2), network(3), both(4)  

atmNteConfOamAddressing 1.3.6.1.4.1.164.12.3.1.1.9.3
OBJECT IDENTIFIER    

atmNteConfLoopbackAddMode 1.3.6.1.4.1.164.12.3.1.1.9.3.1
Loopback addressing mode. on - will enable loopback addressing. off - will disable loopback addressing.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

atmNteConfLoopbackSourceAdd 1.3.6.1.4.1.164.12.3.1.1.9.3.2
Loopback source address. This field is relevant when atmNteConfOamAddMode is on.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(2..20)  

atmNteConfOamIfTable 1.3.6.1.4.1.164.12.3.1.1.9.4
OAM support per ATM interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmNteConfOamIfEntry

atmNteConfOamIfEntry 1.3.6.1.4.1.164.12.3.1.1.9.4.1
.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmNteConfOamIfEntry  

atmNteConfOamIfAisRdi 1.3.6.1.4.1.164.12.3.1.1.9.4.1.1
This parameter controls the generation of F4/F5 AIS and RDI due to lower order problems such as physical layer problems. For AIS: Defines if F4/F5 AIS cell is transmitted due to problems such as physical layer alarm or F4/F5 defect. This is applicable for all ports . off - Problems in this port will not trigger F4/F5 AIS transmition to the ajacent port (e.g. from USER to NETWORK) of a VPC/VCC. on - Problems in this port will trigger F4/F5 AIS transmition to the ajacent port (e.g. from USER to NETWORK) of a VPC/VCC. For RDI: Defines if F4/F5 RDI cell will be transmitted due to physical layer problems in that port (in addition to F4/F5 RDI cells transmitted due to ATM layer problems). For example, If it is enabled for Network port, then physical layer defect will initiate the transmission of F4/F5 RDI cell back to the trunk. The type of F4/F5 (Segment or End-to-End) is according to the configuration of the VPC/VCC.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

atmNteConfCAC 1.3.6.1.4.1.164.12.3.1.1.10
OBJECT IDENTIFIER    

atmNteConfCACMode 1.3.6.1.4.1.164.12.3.1.1.10.1
CAC support mode. For ACE2002, the following are the applicable values: disable(1), enable(2), 10 - 1000.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

atmNteHostIfTable 1.3.6.1.4.1.164.12.3.1.1.11
Host IP interface table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmNteHostIfEntry

atmNteHostIfEntry 1.3.6.1.4.1.164.12.3.1.1.11.1
.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmNteHostIfEntry  

atmNteHostPvcIndex 1.3.6.1.4.1.164.12.3.1.1.11.1.1
A PVC index. The range is 1..10.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmNteHostIP 1.3.6.1.4.1.164.12.3.1.1.11.1.2
The host interface IP address.
Status: current Access: read-create
OBJECT-TYPE    
  IpAddress  

atmNteHostMask 1.3.6.1.4.1.164.12.3.1.1.11.1.3
The host interface subnet mask.
Status: current Access: read-create
OBJECT-TYPE    
  IpAddress  

atmNteHostAtmIfIndex 1.3.6.1.4.1.164.12.3.1.1.11.1.4
ATM interface index. Will be 1 for user port, and 2 for network port.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

atmNteHostVpi 1.3.6.1.4.1.164.12.3.1.1.11.1.5
VPI of the PVC connected to that host interface.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

atmNteHostVci 1.3.6.1.4.1.164.12.3.1.1.11.1.6
VCI of the PVC connected to that host interface.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

atmNteHostRowStatus 1.3.6.1.4.1.164.12.3.1.1.11.1.7
Creation/Deletion of rows in the table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

atmNteHostRdnVpi 1.3.6.1.4.1.164.12.3.1.1.11.1.8
The VPI of the redundant management VCL. This parameter is applicable only if atmNteRdnManagement=enable(3).
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

atmNteHostRdnVci 1.3.6.1.4.1.164.12.3.1.1.11.1.9
The VCI of the redundant management VCL. This parameter is applicable only if atmNteRdnManagement=enable(3).
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

atmNteHostDefaultNextHop 1.3.6.1.4.1.164.12.3.1.1.11.1.10
The host interface Default Next Hop address. This address will be used as default next hop for every Bundle mapped to this Host.
Status: current Access: read-create
OBJECT-TYPE    
  IpAddress  

atmNteHostVlanTagging 1.3.6.1.4.1.164.12.3.1.1.11.1.11
VLAN Tag support. no - No support to VLAN. yes - 4 VLAN bytes will be added to each frame connected to this Host.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

atmNteHostDefaultVlanID 1.3.6.1.4.1.164.12.3.1.1.11.1.12
Default VLAN ID of this Host.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

atmNteHostDefaultVlanPriority 1.3.6.1.4.1.164.12.3.1.1.11.1.13
Default VLAN priority for this Host.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

atmNteShaperMode 1.3.6.1.4.1.164.12.3.1.1.12
Shaper Mode. vpInbandMng - Vcc within a Vp for management.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER normal(1), group(2), aggregate(3), vpInbandMng(4)  

atmNteOutputRate 1.3.6.1.4.1.164.12.3.1.1.13
Aggregate shaping output rate in Cells per Seconds units. Default value is the Network port rate.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmNteTosMode 1.3.6.1.4.1.164.12.3.1.1.14
TOS Mode.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

atmNteTosMask 1.3.6.1.4.1.164.12.3.1.1.15
This parameter determines the seqence of bits that will be used for TOS. For ACE101 this parameter is applicable only if atmNteTosMode = enable. Valid only for IP-TOS process.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1)  

atmNteTosHighPriority 1.3.6.1.4.1.164.12.3.1.1.16
Priorities options are High or Low. High priority will be represented by bit = 1. Low priority will be represented by bit = 0. Each TOS value will be represented by the bit location. For example, the string for TOS 2, 9, 15 with High priority, will be: |0000 0000|... ...|0000 0000|1000 0010|0000 0100| ...98 7654 3210 (Bit #) 8 ... 3 2 1 (Byte #).
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8)  

atmNtePlugAndPlayActivity 1.3.6.1.4.1.164.12.3.1.1.17
Activity control for Manager Plug And Play. disable - disable the feature. offline - Automatic learn IP address into offline memory. online - Automatic learn IP address into online memory.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), offline(2), online(3)  

atmNteSlotUsage 1.3.6.1.4.1.164.12.3.1.1.18
Applicable to ace2002. Slot 2 might be configured as user slot or as network slot.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), user(2), network(3)  

atmNteConnectionsMaxNumber 1.3.6.1.4.1.164.12.3.1.1.19
The MAX number of connections supported by system. Setting this parameter will affect the number of MAX intervals supported. This parameter will affect the system only after reset. Changing this parameter from high value to a low value, will be accepted by agent only if the actual used connection <= the desired connection Max number. Applicable to ace2002.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), max1024(2), max2048(3)  

atmNteDefaultVpi 1.3.6.1.4.1.164.12.3.1.1.20
Default Vpi for management.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmNteDefaultVci 1.3.6.1.4.1.164.12.3.1.1.21
Default Vci for management.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmNteReservedVpi 1.3.6.1.4.1.164.12.3.1.1.22
Internal use VPI, where shaperMode=vpInbandMng.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..255  

atmNteRdnManagement 1.3.6.1.4.1.164.12.3.1.1.23
The redundancy management status.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER disabled(2), enabled(3)  

atmNtePlugAndPlayIfIndex 1.3.6.1.4.1.164.12.3.1.1.24
The ifIndex of the Plug and Play VCC.
Status: current Access: read-write
OBJECT-TYPE    
  InterfaceIndex  

atmNteLoopbackTimeout 1.3.6.1.4.1.164.12.3.1.1.25
The Loopback state timeout in minutes. A value of zero means no timeout (for ever). Default is 5 min.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmNteOamTable 1.3.6.1.4.1.164.12.3.1.1.26
This table is a static table, which is created by agent once upon initialization. The created entries are actually, only the supported OAM features. This table enables addition of new features by adding new entries rather than adding scalar parameters. An OAM feature is defined by the indexes values combination.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmNteOamEntry

atmNteOamEntry 1.3.6.1.4.1.164.12.3.1.1.26.1
An entry in the OAM table. Each entry in this table will indicate a special OAM.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmNteOamEntry  

atmNteOamMode 1.3.6.1.4.1.164.12.3.1.1.26.1.1
The OAM cell path. endToEnd(1) - the entire path.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER endToEnd(1)  

atmNteOamCellType 1.3.6.1.4.1.164.12.3.1.1.26.1.2
This object indicates a unique Indication Signal. aisAndRdi(1) - Alarm Indication Signal (AIS) and Remote Defect Indication (RDI) cell. loopback(2) - Loopback cell.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER aisAndRdi(1), loopback(2)  

atmNteOamLevel 1.3.6.1.4.1.164.12.3.1.1.26.1.3
The level of the OAM cell. -- f4 (2) - VP level, f5 (3) - VC level.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER f5(3)  

atmNteOamEnable 1.3.6.1.4.1.164.12.3.1.1.26.1.4
This parameter determines if the specified OAM cells will be enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(2), enable(3)  

atmNteDefaultLoopbackThreshold 1.3.6.1.4.1.164.12.3.1.1.27
The Default OAM Loopback Failure Threshold value that will be used for configuration.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmNteMaxBurstSize 1.3.6.1.4.1.164.12.3.1.1.28
The Maximum allowed burst size (cell units). This object is applicable for each Physical port.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmNteGranularityFactor 1.3.6.1.4.1.164.12.3.1.1.29
This parameter affects the granularity of the guaranteed Rate (SCR+MCR) in spaced connection (cell/sec units). It is also defines the minimum guaranteed rate in spaced connection.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmNteTotalInputRate 1.3.6.1.4.1.164.12.3.1.1.30
This parameter indicates the total input rate of the device in cells/sec.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmNteTotalOutputRate 1.3.6.1.4.1.164.12.3.1.1.31
This parameter indicates the total output rate of the device in cells/sec.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmAlarmForwardingTable 1.3.6.1.4.1.164.12.3.1.1.32
The Alarm Forwarding Mechanism will be operated for this table entries.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmAlarmForwardingEntry

atmAlarmForwardingEntry 1.3.6.1.4.1.164.12.3.1.1.32.1
Each entry in this table is a pair of ports that the Alarm Forwarding Mechanism is determined for.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmAlarmForwardingEntry  

atmAlarmForwardingFailPort 1.3.6.1.4.1.164.12.3.1.1.32.1.1
An Index of the port on which a fail occurs.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

atmAlarmForwardingToPort 1.3.6.1.4.1.164.12.3.1.1.32.1.2
An Index of the port that will be affected upon the failure of the atmAlarmForwardingFailPort.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

atmAlarmForwardingRowStatus 1.3.6.1.4.1.164.12.3.1.1.32.1.3
Creation/Deletion of rows in the table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

atmAlarmForwardingFailureLevel 1.3.6.1.4.1.164.12.3.1.1.32.1.4
This parameter determines the level of failure that will operate the Alarm Forwarding Mechanism.
Status: current Access: read-create
OBJECT-TYPE    
  BITS physical(0), atm(1)  

atmAlarmForwardingRecoveryMode 1.3.6.1.4.1.164.12.3.1.1.32.1.5
This parameter determines the Recovery Mode. manual - The user should stop the RDI transmission by using the atmAlarmForwardingRecoveryCommand. automatic - The RDI transmission will be automatically stopped upon atmAlarmForwardingFailPort recovery.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER manual(1), automatic(2)  

atmAlarmForwardingRecoveryCommand 1.3.6.1.4.1.164.12.3.1.1.32.1.6
This parameter is a command. It is applicable when atmAlarmForwardingRecoveryMode = manual. on - Will stop the RDI transmission. After setting to 'On' the agent will set this parameter back to 'Off'.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER off(2), on(3)  

atmAlarmForwardingTimeFilterWindow 1.3.6.1.4.1.164.12.3.1.1.32.1.7
This parameter determines the Time Filter Window, meaning: how much time (in seconds) should the alarm exist in order to start the Alarm Forwarding operation.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

atmSysConfigCellTest 1.3.6.1.4.1.164.12.3.1.1.33
OBJECT IDENTIFIER    

atmSysConfigCellTestPort 1.3.6.1.4.1.164.12.3.1.1.33.1
An Index of the port on which the cell test will be sent.
Status: current Access: read-write
OBJECT-TYPE    
  InterfaceIndex  

atmSysConfigCellTestVpi 1.3.6.1.4.1.164.12.3.1.1.33.2
The VPI on which the cell test will be sent.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmSysConfigCellTestVci 1.3.6.1.4.1.164.12.3.1.1.33.3
The VCI on which the cell test will be sent.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmSysConfigCellTestPti 1.3.6.1.4.1.164.12.3.1.1.33.4
The cell type.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER user(1), oamSegment(2), oamEndToEnd(3)  

atmSysConfigCellTestClp 1.3.6.1.4.1.164.12.3.1.1.33.5
The type of the Cell.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER clp0(1), clp1(2)  

atmSysConfigCellTestOamType 1.3.6.1.4.1.164.12.3.1.1.33.6
The OAM type of the Cell. This object is applicable if atmSysConfigCellTestPti = oamSegment/oamEndToEnd .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ais(1), rdi(2), cc(3), lb(4)  

atmSysConfigCellTestPayload 1.3.6.1.4.1.164.12.3.1.1.33.7
The payload of the cell. For OAM cell the payload is set automatically to 6A.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1)  

atmSysConfigCellTestQuantity 1.3.6.1.4.1.164.12.3.1.1.33.8
Quantity of cells to send.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..10000  

atmSysConfigCellTestSendCmd 1.3.6.1.4.1.164.12.3.1.1.33.9
Setting the variable to send(3) perfroms cell test. The agent will immediately reset the variable to off(2).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), send(3)  

atmVpCrossConnectExtenTable 1.3.6.1.4.1.164.12.3.1.1.34
An extension to the ATM VP Cross Connect table (RFC2515 - atmVpCrossConnectTable).
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmVpCrossConnectExtenEntry

atmVpCrossConnectExtenEntry 1.3.6.1.4.1.164.12.3.1.1.34.1
An entry in the table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmVpCrossConnectExtenEntry  

atmVpCrossConnectName 1.3.6.1.4.1.164.12.3.1.1.34.1.1
The Connection's name.
Status: current Access: read-create
OBJECT-TYPE    
  SnmpAdminString Size(1..64)  

atmVcCrossConnectExtenTable 1.3.6.1.4.1.164.12.3.1.1.35
An extension to the ATM VC Cross Connect table (RFC2515 - atmVcCrossConnectTable).
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmVcCrossConnectExtenEntry

atmVcCrossConnectExtenEntry 1.3.6.1.4.1.164.12.3.1.1.35.1
An entry in the table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmVcCrossConnectExtenEntry  

atmVcCrossConnectName 1.3.6.1.4.1.164.12.3.1.1.35.1.1
The Connection's name.
Status: current Access: read-create
OBJECT-TYPE    
  SnmpAdminString Size(1..64)  

atmNteQosMode 1.3.6.1.4.1.164.12.3.1.1.37
This variable defines the QoS Mode. disable(1) - QoS is disabled. multipleVc(2) - QoS is enabled and multiple VCs can be bound per bridge port. singleVc(3) - QoS is enabled and only single VC can be bound per bridge port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), multipleVc(2), singleVc(3)  

atmTrafficDescrParamXTable 1.3.6.1.4.1.164.12.3.1.1.38
An Augment to ATM Traffic Descriptor Parameter Table (atmTrafficDescrParamTable in ATM-MIB; RFC-2515).
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmTrafficDescrParamXEntry

atmTrafficDescrParamXEntry 1.3.6.1.4.1.164.12.3.1.1.38.1
An entry in the table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmTrafficDescrParamXEntry  

atmTrafficDescrParamMode 1.3.6.1.4.1.164.12.3.1.1.38.1.1
The Mode of the Traffic Descriptor.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER scheduling(1), schedulingAndShaping(2), policing(3)  

atmNteSysInfo 1.3.6.1.4.1.164.12.3.1.2
OBJECT IDENTIFIER    

atmNteIdTable 1.3.6.1.4.1.164.12.3.1.2.1
The IDs of the cards and of the system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmNteIdEntry

atmNteIdEntry 1.3.6.1.4.1.164.12.3.1.2.1.1
.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmNteIdEntry  

atmNteIdIndex 1.3.6.1.4.1.164.12.3.1.2.1.1.1
An Index of the Unit ID table. The following units have IDs in this table: 1 - System 2 - ATM Board 3 - User Card 4 - Trunk 1 card 5 - Trunk 2 card 6 - Shaper 7 - Clock Unit 8 - Slot 1 card 9 - Slot 2 card 10 - Slot 3 card 11 - Slot 4 card 12 - Fan1 13 - Fan2 14 - Control Unit.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmNteUnitId 1.3.6.1.4.1.164.12.3.1.2.1.1.2
The ID of the Unit. For index = 6, the id will describe the validity of a shaper in the system: 0 - Shaper Not exist 1 - Shaper exist. For index = 7, the id will describe the validity of a clock in the system: 0 - Clock Not exist 1 - Clock exist. 2- Clock exist but failed. For index = 12,13 the id will describe the functionality of a FAN1 : 0 - OK 1 - Failed.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmNteUnitVersion 1.3.6.1.4.1.164.12.3.1.2.1.1.3
Hardware and Software version of the module.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

atmNteCardType 1.3.6.1.4.1.164.12.3.1.2.1.1.4
The card type.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), sc13mR155(2), st13sR155(3), st13lR155(4), utpR155(5), cxBncR155(6), e3(7), t3(8), e1(9), e1Ltu(10), fc13lR155(11), fc13lhR155(12), fc15lhR155(13), fc13lE3(14), fc13lhE3(15), fc15lhE3(16), fc13lT3(17), fc13lhT3(18), fc15lhT3(19), t1(20), eth(21), ethE1CesBnc(22), ethE1CesRj45(23), ethT1CesRj45(24), e1CesRj45(25), e1CesBnc(26), t1CesRj45(27), e14Ces(28), e14CesRj45(29), t14CesRj45(30), hdlc4port(31), hdlcE14CesBnc(32), hdlcE14CesRj45(33), hdlcT14CesRj45(34), e1Rj45(35), e1Bnc(36), ethE14CesBnc(37), ethE14CesRj45(38), ethT14CesRj45(39), hdlc1portHssi(40), hdlcHssiE14CesBnc(41), hdlcHssiE14CesRj45(42), hdlcHssiT14CesRj45(43), e14ImaRj45(44), e14ImaBnc(45), t14ImaRj45(46), ethE3CesBnc(47), ethT3CesBnc(48), smSf1R155(49), smSf2R155(50), sc13sR155(51), sc13lR155(52), utp25(53), sc13lhR155(54), sc15lhR155(55), sc13ljR155(56), sc13lhjR155(57), sc15lhjR155(58), e18Ces(59), e18CesRj45(60), t18CesRj45(61), sc13mR622(62), sc13lR622(73), sc13lhR622(74), sc15lhR622(75), fr4Port(76), t3j(77), fr1Port(78), hdlc1Port(79), sc13mR155D(80), sc13lR155D(81), fc13lR155D(82), st13lR155D(83), sc13lhR155D(84), fc13lhR155D(85), st13lhR155D(86), e18ImaBnc(87), e18ImaRj45(88), t18ImaRj45(89), lanUtpE(90), lanLc13lE(91), lanLc13mE(92), e14ImaRj45CfgMode(93), e14ImaBncCfgMode(94), t14ImaRj45CfgMode(95), sc13mR155R(96), sc13lR155R(97), fc13lR155R(98), st13lR155R(99), sc13lhR155R(100), fc13lhR155R(101), st13lhR155R(102), fEthUtpD(103), fEthSmD(104), fEthMmD(105), e14CesRj45Unbal(106), sc13mR155n(107), sc13lR155n(108), sc13lhR155n(109), sc15lhR155n(110), fc13lR155n(111), fc13lhR155n(112), fc15lhR155n(113), st13lR155n(114), lanUtp(115), lanLc13l(116), lanLc13m(117), e1FrHdlc(118), e1FrHdlcUnbal(119), t1FrHdlc(120), channelizedT3(121), fc15lhR155D(122), sc15lhR155D(123), smSf1R155D(124), smSf2R155D(125), smSf3R155D(126), fc15lhR155R(127), sc15lhR155R(128), smSf1R155R(129), smSf2R155R(130), smSf3R155R(131), st13lhR155n(132), smSf1R155n(133), smSf2R155n(134), smSf3R155n(135), t18CesNg(136), e18CesUnbalNg(137), e18CesBalNg(138), t14CesNg(139), e14CesUnbalNg(140), e14CesBalNg(141), t18ImaUniNg(142), e18ImaUniUnbalNg(143), e18ImaUniBalNg(144), t14ImaUniNg(145), e14ImaUniUnbalNg(146), e14ImaUniBalNg(147), t1Ces(148), e1CesUnbal(149), e1CesBal(150), switchedLan(151), channelizedSts1(152), st13mR155(153), st13lhR155(154), st15lhR155(155), gigabitEthUtp(156), gigabitEthSfp(157), fastEthUtp(158), fourStm1oc3SingleGbe(159), main8Atm155TwoEth(249), mainChannelized155(250), main(251), control(252), fan(253), unknown(254), empty(255)  

atmNteCardStatus 1.3.6.1.4.1.164.12.3.1.2.1.1.5
Status of the card in the selected slot. notActive - Connections are in NotReady state. No configuration is available for the card. The access to the card HW is blocked. This state is relevant for an extracted card, and for a case in which the card was deactivated. active - The module installed and functions. A card that in this state can be configured. inProgress - The status during proccessing of a command from atmNteCardCmd. empty - No information is valid for the selected slot. This status is relevant to a case in which the card configaration was deleted, or in case in which a slot was empty since the device startup.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), notActive(2), active(3), inProgress(4), empty(5)  

atmNteCardCmd 1.3.6.1.4.1.164.12.3.1.2.1.1.6
Command on the card that is installed in the selected slot. The commands are applicable according to the value of atmNteCardStatus. See the specification document for details. deleteConfig - Deletes the card configuration. deactivate - All the connections state will be changed to NotReady. The card configuration will be blocked. activate - Does the same as done upon card insertion: Initiates the relevant parameters, activates the physical layer, ATM layer and logical layer.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), deleteConfig(2), deactivate(3), activate(4)  

atmNteProgCardType 1.3.6.1.4.1.164.12.3.1.2.1.1.7
The programmed card type.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER fourStm1oc3SingleGbe(159), main8Atm155TwoEth(249), mainChannelized155(250), main(251), control(252), fan(253), empty(255), atm155(1001), eth(1002), channelized155(1003)  

atmSysPSunits 1.3.6.1.4.1.164.12.3.1.2.2
The number of power supply units.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmSysPSunitsInUse 1.3.6.1.4.1.164.12.3.1.2.3
The main power supply in this unit.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER ps1(2), ps2(3)  

atmSysFanUnits 1.3.6.1.4.1.164.12.3.1.2.4
The number of fan units.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmSysNetPrts 1.3.6.1.4.1.164.12.3.1.2.5
The number of network ports.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmSysNetPrtInUse 1.3.6.1.4.1.164.12.3.1.2.6
The network port in use.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER trunk1(2), trunk2(3)  

atmNteBridgingMode 1.3.6.1.4.1.164.12.3.1.2.7
Bridging mode can be one of the following: ATM <> Ethernet - Bridging is between the Ethernet port and the ATM port (there is no bridging between VCs). ATM <> Ethernet + ATM - Bridging is done both between the Ethernet port and the ATM port and also between VCs.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER accessOnly(1), accessAndSwitching(2)  

atmSysStats 1.3.6.1.4.1.164.12.3.1.2.8
OBJECT IDENTIFIER    

atmSysCurrentCdc 1.3.6.1.4.1.164.12.3.1.2.8.1
Seconds in which cells dropped was occured in the current 15 minutes interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmSysIntervalTable 1.3.6.1.4.1.164.12.3.1.2.8.2
The system level Interval table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmSysIntervalEntry

atmSysIntervalEntry 1.3.6.1.4.1.164.12.3.1.2.8.2.1
.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmSysIntervalEntry  

atmSysIntervalNumber 1.3.6.1.4.1.164.12.3.1.2.8.2.1.1
A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..96  

atmSysIntervalCdc 1.3.6.1.4.1.164.12.3.1.2.8.2.1.2
Seconds in which cells dropped was occured in 15 minutes interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmNteEventType 1.3.6.1.4.1.164.12.3.1.2.9
This parameter identifies the event. On - the problem exist. Off - the problem not exist. InvalidLogin - Invalid login on local console. CorrectLogin - Successful login operation.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER ps1NotActive(3), ps1Active(4), ps2NotActive(5), ps2Active(6), heatAlarmOff(7), heatAlarmOn(8), inputAlarm1Off(9), inputAlarm1On(10), inputAlarm2Off(11), inputAlarm2On(12), inputAlarm3Off(13), inputAlarm3On(14), inputAlarm4Off(15), inputAlarm4On(16), fan1Ok(17), fan1Fail(18), fan2Ok(19), fan2Fail(20), invalidLogin(21), validLogin(22), powerFailure(23), writeToFlashFailure(24)  

atmNteIntervalMaxNumber 1.3.6.1.4.1.164.12.3.1.2.10
The MAX number of connections intervals supported by system. This parameter value is a function of atmNteConnectionsMaxNumber parameter. This parameter should affect the threshold values selected by user. Applicable to ace2002.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..96  

atmNteAlarmType 1.3.6.1.4.1.164.12.3.1.2.11
This object specifies the type of the alarm.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), ais(2), rdi(3), continuityLoss(4), loopback(5)  

atmNteLevel 1.3.6.1.4.1.164.12.3.1.2.12
This object specifies the ATM level.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER vp(2), vc(3)  

atmNteConnectionsNumber 1.3.6.1.4.1.164.12.3.1.2.13
This object specifies a quantity of connections.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmNteTotalLb 1.3.6.1.4.1.164.12.3.1.2.14
This parameter counts the total number of end-points that were configured with Loopback (LB).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmNteTotalCc 1.3.6.1.4.1.164.12.3.1.2.15
This parameter counts the total number of end-points that were configured with Continuity Check (CC).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmNteTotalPm 1.3.6.1.4.1.164.12.3.1.2.16
This parameter counts the total number of end-points that were configured with PM.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmNteLoopback 1.3.6.1.4.1.164.12.3.2.2
OBJECT IDENTIFIER    

atmLoopbackVpTable 1.3.6.1.4.1.164.12.3.2.2.1
This table contains parameters for an OAM VP loopback test.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmLoopbackVpEntry

atmLoopbackVpEntry 1.3.6.1.4.1.164.12.3.2.2.1.1
An entry in table atmLoopbackVpTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmLoopbackVpEntry  

atmLoopbackVpIfIndex 1.3.6.1.4.1.164.12.3.2.2.1.1.1
The interface index of the ATM layer.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLoopbackVpVpi 1.3.6.1.4.1.164.12.3.2.2.1.1.2
The VPI of the OAM VPL.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLoopbackVpOperStatus 1.3.6.1.4.1.164.12.3.2.2.1.1.3
-noActive(1) means that the loopback test has not been activated for this VP. -inProgress(2) means that the test has been activated and there is currently no problem. -failed(3) means there was problem during the test or after having stopped it -endSuccessfully(4) means that the test was stopped and all was OK.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER noActive(1), inProgress(2), failed(3), endSuccessfully(4)  

atmLoopbackVpCDV 1.3.6.1.4.1.164.12.3.2.2.1.1.4
Cell Delay Variation for this sampling.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLoopbackVpAverageDelay 1.3.6.1.4.1.164.12.3.2.2.1.1.5
Average delay without including lost cells.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLoopbackVpMaxDelay 1.3.6.1.4.1.164.12.3.2.2.1.1.6
Maximum delay without including lost cells.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLoopbackVpMinDelay 1.3.6.1.4.1.164.12.3.2.2.1.1.7
Minimum delay.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLoopbackVpErrSessions 1.3.6.1.4.1.164.12.3.2.2.1.1.8
Errored Sessions. Will be updated once in 5 seconds.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLoopbackVcTable 1.3.6.1.4.1.164.12.3.2.2.2
This table contains parameters for an OAM VC loopback test.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmLoopbackVcEntry

atmLoopbackVcEntry 1.3.6.1.4.1.164.12.3.2.2.2.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmLoopbackVcEntry  

atmLoopbackVcIfIndex 1.3.6.1.4.1.164.12.3.2.2.2.1.1
The interface index of the ATM layer.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLoopbackVcVpi 1.3.6.1.4.1.164.12.3.2.2.2.1.2
The VPI of the OAM VCL.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLoopbackVcVci 1.3.6.1.4.1.164.12.3.2.2.2.1.3
The VCI of the OAM VCL.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLoopbackVcOperStatus 1.3.6.1.4.1.164.12.3.2.2.2.1.4
-noActive(1) means that the loopback test has not been activated for this VP. -inProgress(2) means that the test has been activated and there is currently no problem. -failed(3) means there was problem during the test or after having stopped it -endSuccessfully(4) means that the test was stopped and all was OK.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER noActive(1), inProgress(2), failed(3), endSuccessfully(4)  

atmLoopbackVcCDV 1.3.6.1.4.1.164.12.3.2.2.2.1.5
Cell Delay Variation for this sampling.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLoopbackVcAverageDelay 1.3.6.1.4.1.164.12.3.2.2.2.1.6
Average delay without including lost cells.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLoopbackVcMaxDelay 1.3.6.1.4.1.164.12.3.2.2.2.1.7
The maximum delay without including lost cells.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLoopbackVcMinDelay 1.3.6.1.4.1.164.12.3.2.2.2.1.8
The minimum delay.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLoopbackVcErrSessions 1.3.6.1.4.1.164.12.3.2.2.2.1.9
Errored Sessions. Will be updated once in 5 seconds.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLoopbackVpIvlTable 1.3.6.1.4.1.164.12.3.2.2.3
This table contains parameters for an OAM VP loopback test, according interval number.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmLoopbackVpIvlEntry

atmLoopbackVpIvlEntry 1.3.6.1.4.1.164.12.3.2.2.3.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmLoopbackVpIvlEntry  

atmLoopbackVpIvlIfIndex 1.3.6.1.4.1.164.12.3.2.2.3.1.1
The interface index of the ATM layer.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLoopbackVpIvlVpi 1.3.6.1.4.1.164.12.3.2.2.3.1.2
The VPI of the OAM VPL.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLoopbackVpIvlIvl 1.3.6.1.4.1.164.12.3.2.2.3.1.3
The relevant interval number.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..96  

atmLoopbackVpIvlOperStatus 1.3.6.1.4.1.164.12.3.2.2.3.1.4
-noActive(1) means that the loopback test has not been activated for this VP during this interval. -inProgress(2) has no meaning for an ended interval. -failed(3) means there was problem during the test or after having stopped it -endSuccessfully(4) means that the test was OK.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER noActive(1), inProgress(2), failed(3), endSuccessfully(4)  

atmLoopbackVpIvlCDV 1.3.6.1.4.1.164.12.3.2.2.3.1.5
Cell Delay Variation for this interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLoopbackVpIvlAverageDelay 1.3.6.1.4.1.164.12.3.2.2.3.1.6
Average delay without including lost cells for this interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLoopbackVpIvlMaxDelay 1.3.6.1.4.1.164.12.3.2.2.3.1.7
The maximum delay without including lost cells for this interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLoopbackVpIvlMinDelay 1.3.6.1.4.1.164.12.3.2.2.3.1.8
The minimum delay for this interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLoopbackVpIvlErrSessions 1.3.6.1.4.1.164.12.3.2.2.3.1.9
Errored Sessions. Will be updated once in 5 seconds.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLoopbackVcIvlTable 1.3.6.1.4.1.164.12.3.2.2.4
This table contains parameters for an OAM VC loopback test.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmLoopbackVcIvlEntry

atmLoopbackVcIvlEntry 1.3.6.1.4.1.164.12.3.2.2.4.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmLoopbackVcIvlEntry  

atmLoopbackVcIvlIfIndex 1.3.6.1.4.1.164.12.3.2.2.4.1.1
The interface index of the ATM layer.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLoopbackVcIvlVpi 1.3.6.1.4.1.164.12.3.2.2.4.1.2
The VPI of the OAM VCL.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLoopbackVcIvlVci 1.3.6.1.4.1.164.12.3.2.2.4.1.3
The VCI of the OAM VCL.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLoopbackVcIvlIvl 1.3.6.1.4.1.164.12.3.2.2.4.1.4
The relevant interval number.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..96  

atmLoopbackVcIvlOperStatus 1.3.6.1.4.1.164.12.3.2.2.4.1.5
-noActive(1) means that the loopback test has not been activated for this VC during this interval. -inProgress(2) has no meaning per interval. -failed(3) means there was problem for this test during this interval. -endSuccessfully(4) means that the test was OK.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER noActive(1), inProgress(2), failed(3), endSuccessfully(4)  

atmLoopbackVcIvlCDV 1.3.6.1.4.1.164.12.3.2.2.4.1.6
Cell Delay Variation for this interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLoopbackVcIvlAverageDelay 1.3.6.1.4.1.164.12.3.2.2.4.1.7
Average delay without including lost cells.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLoopbackVcIvlMaxDelay 1.3.6.1.4.1.164.12.3.2.2.4.1.8
The maximum delay without including lost cells.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLoopbackVcIvlMinDelay 1.3.6.1.4.1.164.12.3.2.2.4.1.9
The minimum delay.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLoopbackVcIvlErrSessions 1.3.6.1.4.1.164.12.3.2.2.4.1.10
Errored Sessions. Will be updated once in 5 seconds.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmNtePM 1.3.6.1.4.1.164.12.3.2.3
OBJECT IDENTIFIER    

atmVpPmTable 1.3.6.1.4.1.164.12.3.2.3.1
This table contains parameters for VP performance monitoring.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmVpPmEntry

atmVpPmEntry 1.3.6.1.4.1.164.12.3.2.3.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmVpPmEntry  

atmVpPmIfIndex 1.3.6.1.4.1.164.12.3.2.3.1.1.1
The interface index of the ATM layer.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmVpPmVpi 1.3.6.1.4.1.164.12.3.2.3.1.1.2
The VPI of the Performance Monitoring VPL.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmVpPmAdminStatus 1.3.6.1.4.1.164.12.3.2.3.1.1.3
up(2) - Activate PM. down(3) - Deactivate PM. listenToActivationCells(4) - . originateActivationCells(5) - .
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER up(2), down(3), listenToActivationCells(4), originateActivationCells(5)  

atmVpPmDirection 1.3.6.1.4.1.164.12.3.2.3.1.1.4
The direction of PM.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER source(2), destination(3), bidirectional(4)  

atmVpPmBlockSize 1.3.6.1.4.1.164.12.3.2.3.1.1.5
Valid block sizes (in cells): 128, 256, 512, 1024, 2048, 4096, 8192, 16384, 32768.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

atmVpPmRowStatus 1.3.6.1.4.1.164.12.3.2.3.1.1.6
Creation/Deletion of rows in the table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

atmVpPmSink 1.3.6.1.4.1.164.12.3.2.3.1.1.7
off (1) - Deactivate PM. fwd (2) - Activate Forward PM only. fwdAndBwdReport(3) - Activate Forward PM and Backward reporting.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER off(1), fwd(2), fwdAndBwdReport(3)  

atmVpPmSource 1.3.6.1.4.1.164.12.3.2.3.1.1.8
off (1) - Deactivate PM. fwd (2) - Activate Forward PM only. fwdAndBwdReport(3) - Activate Forward PM and Backward reporting.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER off(1), fwd(2), fwdAndBwdReport(3)  

atmVcPmTable 1.3.6.1.4.1.164.12.3.2.3.2
This table contains parameters for VC performance monitoring.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmVcPmEntry

atmVcPmEntry 1.3.6.1.4.1.164.12.3.2.3.2.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmVcPmEntry  

atmVcPmIfIndex 1.3.6.1.4.1.164.12.3.2.3.2.1.1
The interface index of the ATM layer.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmVcPmVpi 1.3.6.1.4.1.164.12.3.2.3.2.1.2
The VPI of the Performance Monitoring VCL.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmVcPmVci 1.3.6.1.4.1.164.12.3.2.3.2.1.3
The VCI of the PM VCL.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmVcPmAdminStatus 1.3.6.1.4.1.164.12.3.2.3.2.1.4
up(2) - Activate PM. down(3) - Deactivate PM. listenToActivationCells(4) - . originateActivationCells(5) - .
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER up(2), down(3), listenToActivationCells(4), originateActivationCells(5)  

atmVcPmDirection 1.3.6.1.4.1.164.12.3.2.3.2.1.5
The direction of PM.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER source(2), destination(3), bidirectional(4)  

atmVcPmBlockSize 1.3.6.1.4.1.164.12.3.2.3.2.1.6
Valid block sizes (in cells): 128, 256, 512, 1024, 2048, 4096, 8192, 16384, 32768.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

atmVcPmRowStatus 1.3.6.1.4.1.164.12.3.2.3.2.1.7
Creation/Deletion of rows in the table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

atmVcPmSink 1.3.6.1.4.1.164.12.3.2.3.2.1.8
off (1) - Deactivate PM. fwd (2) - Activate Forward PM only. fwdAndBwdReport(3) - Activate Forward PM and Backward reporting.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER off(1), fwd(2), fwdAndBwdReport(3)  

atmVcPmSource 1.3.6.1.4.1.164.12.3.2.3.2.1.9
off (1) - Deactivate PM. fwd (2) - Activate Forward PM only. fwdAndBwdReport(3) - Activate Forward PM and Backward reporting.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER off(1), fwd(2), fwdAndBwdReport(3)  

atmNteMdl 1.3.6.1.4.1.164.12.3.3
OBJECT IDENTIFIER    

atmNteMdlConfig 1.3.6.1.4.1.164.12.3.3.1
OBJECT IDENTIFIER    

atmNteMdlConfigTable 1.3.6.1.4.1.164.12.3.3.1.1
Module configuration table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmNteMdlConfigEntry

atmNteMdlConfigEntry 1.3.6.1.4.1.164.12.3.3.1.1.1
There is an entry in this table just for those modules that have parameters that are relevant to module level only.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmNteMdlConfigEntry  

atmNteMdlSlotIndex 1.3.6.1.4.1.164.12.3.3.1.1.1.1
The slot number.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..4  

atmNteMdlPrtCpuSharing 1.3.6.1.4.1.164.12.3.3.1.1.1.2
This object lets the user decide what will be the CPU sharing between the ports of the module. This object is applicable for modules in which the same CPU handles the traffic of all ports. equal - All ports will have the same CPU resource. port1 - Port 1 will have higher priority than the other ports.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER equal(2), port1(3)  

atmNteMdlInputPriorityMechanism 1.3.6.1.4.1.164.12.3.3.1.1.1.3
This object allows the user to Enable/Disable the Input priority mechanism. This object is applicable for modules with more than one port, in which the total ports input may be greater than the port output. disabled - all LAN VCCs will be transmitted through the same queue (queue 1). Upon congestion frames will be dropped randomly. enabled - the user should configure each port/connection priority. Upon congestion frames will be dropped according to priority.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(2), enabled(3)  

atmGenSystem 1.3.6.1.4.1.164.12.2.2
OBJECT IDENTIFIER    

atmGenSysGen 1.3.6.1.4.1.164.12.2.2.1
OBJECT IDENTIFIER    

atmGenSysSelfTestTable 1.3.6.1.4.1.164.12.2.2.1.1
A table containing the results of the initial testing of the device.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmGenSysSelfTestEntry

atmGenSysSelfTestEntry 1.3.6.1.4.1.164.12.2.2.1.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmGenSysSelfTestEntry  

atmGenSysSelfTestIndex 1.3.6.1.4.1.164.12.2.2.1.1.1.1
A running index for the table.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmGenSysSelfTestResult 1.3.6.1.4.1.164.12.2.2.1.1.1.2
The results of the initial testing of the device.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

atmGenSysSelfTestModule 1.3.6.1.4.1.164.12.2.2.1.1.1.3
The name of module on which the test was performed.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

atmGenSysLogClearAll 1.3.6.1.4.1.164.12.2.2.1.2
Setting the variable to clear(3) removes all entries in the Log Buffer of the agent. The agent will immediately reset the variable to off(2).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), clear(3)  

atmGenSysLogTable 1.3.6.1.4.1.164.12.2.2.1.3
A copy of the log buffer.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmGenSysLogEntry

atmGenSysLogEntry 1.3.6.1.4.1.164.12.2.2.1.3.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmGenSysLogEntry  

atmGenSysLogIndex 1.3.6.1.4.1.164.12.2.2.1.3.1.1
The index of the log buffer.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..2048  

atmGenSysLogMessage 1.3.6.1.4.1.164.12.2.2.1.3.1.2
The log buffer entry message text.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(80)  

atmGenSysSetDefaultConfg 1.3.6.1.4.1.164.12.2.2.1.4
When set to on(3), the agent will set all the configuration parameters to their default values. The variable is then reset to off(2) by the agent. The agent must be reset for the default configuration to apply.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

atmGenSysCxRefTable 1.3.6.1.4.1.164.12.2.2.1.5
A Cross Reference table. The table maintains an index of an object which is also the table index, and a counter that indicates how many times this object was referenced. When using this table for more than one referenced table, which uses the same range of indexes, then the index should be shifted by a unique offset per table. In ACE2002 this table is used for TD and for FR Desc. Thus, the index for FR Descriptor is: FR Descriptor index + offset. The offset is described in the ACE2002 NMS SRS.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmGenSysCxRefEntry

atmGenSysCxRefEntry 1.3.6.1.4.1.164.12.2.2.1.5.1
The entries will be added by the agent upon an entry addition in the referenced tables (TD table, FR Descriptor etc.)
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmGenSysCxRefEntry  

atmGenSysCxRefIndex 1.3.6.1.4.1.164.12.2.2.1.5.1.1
The index specifies an entry in the table of the object.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmGenSysCxRefCounter 1.3.6.1.4.1.164.12.2.2.1.5.1.2
The counter counts the number of references that have been made to the object .
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmAceStatusChange 1.3.6.1.4.1.164.12.3.0.1
The trap is sent every time there is a change in the state of one of the LEDs.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmTrap 1.3.6.1.4.1.164.12.3.0.2
The trap is sent whenever there is a transition from a no alarm state to a state with at least one active alarm. An active alarm state exists if: 1) The atmInterfaceActiveAlarms vector is different than 0. 2) The atmNteAlarmVpTable contains entries. 3) The atmNteAlarmVcTable contains entries. The trap is also sent when a transition into the no alarm state occurs. The second variable will be atmInterfaceActiveAlarms to indicate the kind of the alarm. The trap is not sent more than once in a 10 second interval.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceModuleChangeTrap 1.3.6.1.4.1.164.12.3.0.3
The trap is sent every time a module is changed (Hot swapping). The second variable will be atmNteCardType to indicate the type of card that was inserted. The value empty(255) indicates that a card was taken out.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceRedundancyTrap 1.3.6.1.4.1.164.12.3.0.4
The trap is sent upon change in link as a result of redundancy. The ifIndex parameter indicates the current active link.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceModuleMismatchTrap 1.3.6.1.4.1.164.12.3.0.5
The trap is sent upon starting or stopping of a module mismatch state. A possible mismatch is when the inserted module is other than the programmed one.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceSystemTrap 1.3.6.1.4.1.164.6.1.12.0.6
This trap alerts of major problems in the device.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmForwardingTrap 1.3.6.1.4.1.164.6.1.12.0.7
This trap is sent upon starting or stopping Alarm Forwarding Mechanism.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceDateAndTimeRequest 1.3.6.1.4.1.164.6.1.12.0.8
This trap is sent upon restart. Upon recieving this trap the NMS will set the device's date and time. This trap's purpose is to fix a problem in ACE2002, ACE-2002E, ACE-202. The problem is that the Date and Time is stored in the NVRAM, and when the NVRAM's battery is empty, the device loses this information.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmLOS 1.3.6.1.4.1.164.6.1.12.0.16
This trap indicates Loss Of Signal.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmLOF 1.3.6.1.4.1.164.6.1.12.0.17
This trap indicates Loss Of Frame.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmLCD 1.3.6.1.4.1.164.6.1.12.0.18
This trap indicates Loss of Cell Delineation.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmSLM 1.3.6.1.4.1.164.6.1.12.0.19
This trap indicates Signal Line Mismatch.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmLOP 1.3.6.1.4.1.164.6.1.12.0.20
This trap indicates Loss of Pointer.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmLineAIS 1.3.6.1.4.1.164.6.1.12.0.21
This trap indicates Line AIS.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmPathAIS 1.3.6.1.4.1.164.6.1.12.0.22
This trap indicates Path AIS.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmLineRDI 1.3.6.1.4.1.164.6.1.12.0.23
This trap indicates Line RDI.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmPathRDI 1.3.6.1.4.1.164.6.1.12.0.24
This trap indicates Path RDIand Path RAI(Yellow) for DS1 interfaces.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmSectionBIP 1.3.6.1.4.1.164.6.1.12.0.25
This trap indicates Section Bit Interleave Parity.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmLineBIP 1.3.6.1.4.1.164.6.1.12.0.26
This trap indicates Line Bit Interleave Parity.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmPathBIP 1.3.6.1.4.1.164.6.1.12.0.27
This trap indicates Path Bit Interleave Parity.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmLineFEBE 1.3.6.1.4.1.164.6.1.12.0.28
This trap indicates Line Far End Block Error.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmPathFEBE 1.3.6.1.4.1.164.6.1.12.0.29
This trap indicates Path Far End Block Error.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmPlcpLOF 1.3.6.1.4.1.164.6.1.12.0.30
This trap indicates T3 PLCP Loss Of Frame.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmPlcpYELLOW 1.3.6.1.4.1.164.6.1.12.0.31
This trap indicates T3 Plcp Yellow.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmPlcpBIP 1.3.6.1.4.1.164.6.1.12.0.32
This trap indicates T3 Plcp Bit Interleave Parity.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmPlcpFEBE 1.3.6.1.4.1.164.6.1.12.0.33
This trap indicates T3 Plcp Far End Block Error.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmPlcpP1P2 1.3.6.1.4.1.164.6.1.12.0.34
This trap indicates T3 Plcp Parity errors in P1/P2 bytes.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmUAS 1.3.6.1.4.1.164.6.1.12.0.35
This trap is sent upon UAS start or end per port.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmCluster 1.3.6.1.4.1.164.6.1.12.0.36
This trap is sent upon atmNteAlarmType start or end, for a cluster of VPs/VCs (according to atmNteLevel) with the same alarm on the same physical port. This trap replaces sending the same alarm for a big quantity (the quantity described in the product specification document) of VPs/VCs in order to prevent flooding the NMS and the network with traps.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceHwFailure 1.3.6.1.4.1.164.6.1.12.0.37
This trap is sent upon HW failure per port.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceUnavailableBwTrap 1.3.6.1.4.1.164.6.1.12.0.38
This trap is sent when Bandwidth allocation is > max possible value for the installed card. For ACE2002 this trap will be sent for the following cases: Card insertion - if the total Input and/or Output Bandwidth is over allocated, then the specific card rate will be set to 0 and this trap will be sent with the Input/Output rates values. Upgrade from former version - when an over allocated Bandwidth is detected, this trap will be sent with atmConfIfInputRate=atmConfIfOutputRate=0xFFFFFFFF.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmVpContinuityLoss 1.3.6.1.4.1.164.6.1.12.0.40
This trap indicates Loss of Continuity Check on a VP Connection.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmVpAISReception 1.3.6.1.4.1.164.6.1.12.0.41
This trap indicates AIS Reception on a VP Connection.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmVpRDIReception 1.3.6.1.4.1.164.6.1.12.0.42
This trap indicates RDI Reception on a VP Connection.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmVpErroredCells 1.3.6.1.4.1.164.6.1.12.0.43
This trap indicates Errored Cells on a VP Connection reported by PM.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmVpLostCells 1.3.6.1.4.1.164.6.1.12.0.44
This trap indicates Lost Cells on a VP Connection reported by PM.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmVpMisinsertedCells 1.3.6.1.4.1.164.6.1.12.0.45
This trap indicates Misinserted Cells on a VP Connection reported by PM.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmVpUAS 1.3.6.1.4.1.164.6.1.12.0.46
This trap is sent upon UAS start or end per VP.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmVpLoopback 1.3.6.1.4.1.164.6.1.12.0.47
This trap is sent upon OAM LoopBack fail status per VP.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmVpGCRAViolation 1.3.6.1.4.1.164.6.1.12.0.48
This trap indicates GCRA violation on a VP Connection reported by UPC device.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmVcContinuityLoss 1.3.6.1.4.1.164.6.1.12.0.56
This trap indicates Loss of Continuity Check on a VC Connection.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmVcAISReception 1.3.6.1.4.1.164.6.1.12.0.57
This trap indicates AIS Reception on a VC.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmVcRDIReception 1.3.6.1.4.1.164.6.1.12.0.58
This trap indicates RDI Reception on a VC Connection.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmVcErroredCells 1.3.6.1.4.1.164.6.1.12.0.59
This trap indicates Errored Cells on a VC Connection reported by PM.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmVcLostCells 1.3.6.1.4.1.164.6.1.12.0.60
This trap indicates Lost Cells on a VC Connection reported by PM.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmVcMisinsertedCells 1.3.6.1.4.1.164.6.1.12.0.61
This trap indicates Misinserted Cells on a VC Connection reported by PM.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmVcUnexpectedCell 1.3.6.1.4.1.164.6.1.12.0.62
This trap indicates an unexpected cell from user or network port.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmVcUAS 1.3.6.1.4.1.164.6.1.12.0.63
This trap is sent upon UAS start or end per VC.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmVcLoopback 1.3.6.1.4.1.164.6.1.12.0.64
This trap is sent upon OAM LoopBack fail status per VC.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmVcGCRAViolation 1.3.6.1.4.1.164.6.1.12.0.65
This trap indicates GCRA violation on a VC Connection reported by UPC device.
Status: current Access: read-only
NOTIFICATION-TYPE    

ip2If 1.3.6.1.4.1.164.3.1.6.7
OBJECT IDENTIFIER    

ip2IfTable 1.3.6.1.4.1.164.3.1.6.7.1
Channels Configuration Table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ip2IfEntry

ip2IfEntry 1.3.6.1.4.1.164.3.1.6.7.1.1
Application layer configuration per link
Status: current Access: not-accessible
OBJECT-TYPE    
  Ip2IfEntry  

ip2IfChannelIndex 1.3.6.1.4.1.164.3.1.6.7.1.1.1
The channel index, which is actualy the bundle ID.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ip2IfRowStatus 1.3.6.1.4.1.164.3.1.6.7.1.1.2
This parameter allows NMS to create/delete entries of this table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

ip2IfOperStatus 1.3.6.1.4.1.164.3.1.6.7.1.1.3
The actual link status. remoteFail - No Rx. localFail - No Tx. unavailable - No echo replay or replay with invalid code or when connection is in Test state. valiodationFail - Connection is in not valid state. standby - offline (can be in pre-sync mode). tdmFail - oper status is down cause of failure in the tdm. hwMismatch - the bundle exists on a card that is not installed or has a different type than the programmed card.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER down(2), up(3), disabled(4), remoteFail(5), localFail(6), unavailable(7), validationFail(8), standby(9), tdmFail(10), hwMismatch(11)  

ip2IfAdminStatus 1.3.6.1.4.1.164.3.1.6.7.1.1.4
The desired state of the link.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER down(2), up(3)  

ip2IfDestAddr 1.3.6.1.4.1.164.3.1.6.7.1.1.5
The destination IP address.
Status: current Access: read-create
OBJECT-TYPE    
  IpAddress  

ip2IfNextHop 1.3.6.1.4.1.164.3.1.6.7.1.1.6
The next hop to which the frame should be sent. Default value - 0.0.0.0. Upon setting the default value the frame is sent to the default Gateway.
Status: current Access: read-create
OBJECT-TYPE    
  IpAddress  

ip2IfDestPort 1.3.6.1.4.1.164.3.1.6.7.1.1.7
The destination Bundle at the far-end device.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

ip2IfMacAddr 1.3.6.1.4.1.164.3.1.6.7.1.1.8
The Destination MAC address of the next hop or destination station.
Status: current Access: read-create
OBJECT-TYPE    
  MacAddress  

ip2IfJitterBuffer 1.3.6.1.4.1.164.3.1.6.7.1.1.9
The maximum cell arrival jitter in 10 usec that the reassembly process will tolerate in the cell stream, without producing errors on the CBR service interface. For KM2100: KML.11 - The range that will be used is 3...300 msec in steps of 1 msec. For Vmux: The range that will be used is 20...100 msec in steps of 10 msec.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

ip2IfTos 1.3.6.1.4.1.164.3.1.6.7.1.1.10
The TOS (Type of Service) value: 0..255. In Vmux-2100/110 devices versions 3.1 and up, in Vmux-210 and in Vmux-4x0: LSB 8 bits - 00 00 00 XX will be used for Signaling packets TOS. Next 8 bits - 00 00 XX 00 will be used for Media packets TOS. Next 16 bits - will be 0. XX = Hex values: 0..FF For mixed packets, TOS of Media Packets will be used. Signaling packets are for example: Keep alive packets and ABCD signaling bits. Media packets are for example: voice, fax, HDLC, payload packets.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

ip2IfTDMBytesInFrame 1.3.6.1.4.1.164.3.1.6.7.1.1.11
The number of TDM bytes to be placed in a single IP frame payload. For ip2IfTDMoIpMode = cesOverPsn this parameter indicates the number of IP frames, calculated as: 1440/.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

ip2IfVlanSupport 1.3.6.1.4.1.164.3.1.6.7.1.1.12
VLAN support (Tagging). no - No support to VLAN. yes - 4 VLAN bytes will be added to the frame.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

ip2IfVlanIdentifier 1.3.6.1.4.1.164.3.1.6.7.1.1.13
VLAN ID.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

ip2IfVlanFramePriority 1.3.6.1.4.1.164.3.1.6.7.1.1.14
VLAN Frame priority.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

ip2IfExitPort 1.3.6.1.4.1.164.3.1.6.7.1.1.15
This object determines to which external port the traffic will be sent. auto - the device will decide automatically the exit port. If there is an option for Tx via more than one ETH card then use ext1 (1) and ext2(2) for ETH card #1 (ex. LAN1 or Ggabit-ETH1) and use card2Ext1(5) and card2Ext2(6) for card #2 (ex. LAN1 or Ggabit-ETH1). In Vmux-110/210 ext5 is used for ETH-NET, ext 6 is used for E1/T1 link and ext7 is used for Serial Link. In Vmux-2100 Main Board: ext 5 is used for ETH-NET, ext 6 is used for E1/T1 link A, prtE1T1B is used for E1/T1 link B and prtEthUser is used for ETH-User. prt17(10) - prt20(13) values were added in order to support Gmux2000 VMX Card.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER notApplicable(1), ext1(2), ext2(3), auto(4), card2Ext1(5), card2Ext2(6), ext5(7), ext7(8), ext6(9), prt17(10), prt18(11), prt19(12), prt20(13), prtE1T1B(14), prtEthUser(15), card3Ext1(16), card3Ext2(17), card3Ext3(18), card3Ext4(19), card4Ext1(20), card4Ext2(21), card4Ext3(22), card4Ext4(23), card1Ext3(24), card1Ext4(25), card1Ext5(26), card1Ext6(27), card1Ext7(28), card1Ext8(29), card2Ext3(30), card2Ext4(31), card2Ext5(32), card2Ext6(33), card2Ext7(34), card2Ext8(35)  

ip2IfVoiceOos 1.3.6.1.4.1.164.3.1.6.7.1.1.16
Voice Out-Of-Service code. Valid range: (0 - FF HEX). For agents that do not support this feature, the value will always be 0.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING  

ip2IfDataOos 1.3.6.1.4.1.164.3.1.6.7.1.1.17
Data Out-Of-Service code. Valid range: (0 - FF HEX). For agents that do not support this feature, the value will always be 0.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING  

ip2IfBundleUsage 1.3.6.1.4.1.164.3.1.6.7.1.1.18
The Bundle Resource usage in Kbps.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ip2IfOAM 1.3.6.1.4.1.164.3.1.6.7.1.1.19
This parameter determine the OAM configuration. The LSB (Bit 0 the most right one) is used for OAM connectivity. Values: 0 = disable, 1= enable.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING  

ip2IfTDMoIpMode 1.3.6.1.4.1.164.3.1.6.7.1.1.20
The TDMoIP Mode configuration. Static- means TS can Tx any time. dynamicLES - means TS can Tx only when line is enabled according to LES protocol. dynamicCAS - means TS can Tx only when line is enabled according to CAS protocol. cesOverIp - use for information that this bundle is used for CES Over IP. voiceOverMpls - Voice over Multi Protocol Label Switching. hdlc - High Level Data Link. voIpComprHeader - indicates proprietary compressed IP header packets. voMplsComprHeader - indicates proprietary compressed MPLS header packets.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER notApplicable(1), static(2), dynamicLES(3), dynamicCAS(4), cesOverIp(5), voiceOverMpls(6), hdlc(7), voIpComprHeader(8), voMplsComprHeader(9), satop(10), cesOverPsn(11), hdlcOverPsn(12)  

ip2IfTimeElapsed 1.3.6.1.4.1.164.3.1.6.7.1.1.21
The number of seconds that have elapsed since the beginning of the current error-measurement period. If, for some reason, such as an adjustment in the system's time-of-day clock, the current interval exceeds the maximum value, the agent will return the maximum value.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..899  

ip2IfValidIntervals 1.3.6.1.4.1.164.3.1.6.7.1.1.22
The number of previous intervals for which data was collected. The value will be 96 unless the interface was brought online within the last 24 hours, in which case the value will be the number of complete 15 minute intervals since the interface has been online.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..96  

ip2IfFarEndType 1.3.6.1.4.1.164.3.1.6.7.1.1.23
This object defines the type of the Far-End device. This data is important for signaling and DS0 format. For Vmux: e1 (2) value is used for a PBX in the Far End. fxs (5) is used for Phone. Other values are not used.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER notApplicable(1), e1(2), t1Esf(3), t1D4(4), fxs(5), serialLink(6), t1Unframed(7)  

ip2IfRdnState 1.3.6.1.4.1.164.3.1.6.7.1.1.24
This object defines the role this bundle plays in the redundancy scheme: none(2) - means this bundle is not part of redundancy pair. primary/ secondary - means this bundle is not part of redundancy pair, and that is the primary bundle or the secondary bunle.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), none(2), primary(3), secondary(4)  

ip2IfSourceAddr 1.3.6.1.4.1.164.3.1.6.7.1.1.25
Source IP Address of the bundle.
Status: current Access: read-create
OBJECT-TYPE    
  IpAddress  

ip2IfBandWidth 1.3.6.1.4.1.164.3.1.6.7.1.1.26
Defines the Bandwidth of the bundle. For TDM bundles - it is the Number of Time Slots in The Bundle. - For T1 the value will be: 1..24 - For E1 the value will be: 1..31 - For T3 the value will be: 1..84 - For E3 the value will be: 1..63 This parameter is required for devices like Emux where the bandwidth of the bundles is unknown. The bundles that are received should be transmitted without any change in the bandwidth. It is the user's responsibility to enter the correct bandwidth. For Ethernet bundles - it is the bandwidth, measured in Kbps.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

ip2IfMeasuredSilence 1.3.6.1.4.1.164.3.1.6.7.1.1.27
This object shows the percentage of Silence that was measured by the device for the current bundle in the transmitted payload. Relevant values: 0..100, 255. Default value is 50. 0 means that there is no silence on the line. 100 means that there is only silence. In this case, there might be no traffic. 255 - value for not applicable or unknown.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ip2IfPayloadType 1.3.6.1.4.1.164.3.1.6.7.1.1.28
This object defines the TDMoIP payload type.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER notApplicable(1), data(2), voice(3), voiceAndCas(4)  

ip2IfProtocolVersion 1.3.6.1.4.1.164.3.1.6.7.1.1.29
This object defines the TDMoIP protocol Version.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER notApplicable(1), v1(2), v2(3)  

ip2IfTdmBackUpNextHop 1.3.6.1.4.1.164.3.1.6.7.1.1.30
Defines the TDM bundle default router in case there was a switch from the Primary Link (for example an ETH port) to a TDM backup Link like E1, T1 or Serial Link. This parameter is relevant only when a Backup Link is configured. When a Backup Link is not configured the value will be: 0.0.0.0
Status: current Access: read-create
OBJECT-TYPE    
  IpAddress  

ip2IfOosTxEnable 1.3.6.1.4.1.164.3.1.6.7.1.1.31
This object defines whether OOS will be Transmitted. Note that for IPmux1000 the Lbit is always sent, but the OOS will be sent according to user selection in this parameter.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

ip2IfConnCheckPktFrequency 1.3.6.1.4.1.164.3.1.6.7.1.1.32
Time in sec. between 2 Bundle Connectivity Check packets. Valid values: 0..60. 0 = Not Applicable.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

ip2IfConnPktTimeOutCycles 1.3.6.1.4.1.164.3.1.6.7.1.1.33
No. of cycles the agent will send Bundle Connectivity packets without receiving a response from the remote device before declaring that the bundle connection to the remote side is down - Time Out. Valid values: 0..5. 0 = Not Applicable.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

ip2IfMfRelay 1.3.6.1.4.1.164.3.1.6.7.1.1.34
Multi Frequency Signaling Detection.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

ip2IfTxGain 1.3.6.1.4.1.164.3.1.6.7.1.1.35
Transmit gain in dBm.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

ip2IfSuperTandem 1.3.6.1.4.1.164.3.1.6.7.1.1.36
The Super Tandem feature provides end to end compression over multiple hops, solving the double compression problem detected in Voice compressing systems. The Super Tandem allows transmission of compressed voice between a few Vmux 2100 hubs, and eliminates the need to decompress an recompress it over each voice card and PBX, thus improving voice quality and reducing delay.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

ip2IfSrcPort 1.3.6.1.4.1.164.3.1.6.7.1.1.37
The source Bundle at the local device, this parameter used for cases where there is no match between ip2IfChannelIndex and the Source Bundle ID.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

ip2IfModemCalls 1.3.6.1.4.1.164.3.1.6.7.1.1.38
This MIB object shows whether Modem Calls are enabled via the bundle. relay option (3) means that the bundle will send to the network only modulated data.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER disable(2), enable(3), relay(4)  

ip2IfMinPulseWidth 1.3.6.1.4.1.164.3.1.6.7.1.1.39
Indicates the minimum width in milliseconds of the MF (Multi Frequency) tone transmitted by the switch. Valid values: 45-300 msec. notApplicable=0.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

ip2IfMinPowerLevel 1.3.6.1.4.1.164.3.1.6.7.1.1.40
Indicates the minimum power level in dBm of the MF (Multi Frequency) tone transmitted by the switch. Valid values: -1...-35 dBm.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

ip2IfEchoCanceler 1.3.6.1.4.1.164.3.1.6.7.1.1.41
Echo canceler activation.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER off(2), on(3)  

ip2IfCodingLaw 1.3.6.1.4.1.164.3.1.6.7.1.1.42
This attribute indicates the Method/Law for decoding/encoding the voice information. aLaw(1) is the standard Law for E1 links. uLaw(2) is the standard Law for T1 links.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER aLAW(1), uLAW(2)  

ip2IfCustomToneDetect 1.3.6.1.4.1.164.3.1.6.7.1.1.43
Custom Tone Detection (COT) is a Control operation of a 2Khz tone detector. This tone is sent between PBX devices in order to check that the line status is OK. When the COT is enabled the device will not compress/decompress the tone. In this case, if the tone is initiated by the local PBX, the Device runs a 2Khz detector tone and once detected by the Remote Device, if the COT is enabled in the Remote Device, the Remote Device will generate a 2khz tone to the remote PBX.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER disable(2), enable(3)  

ip2IfCallerIdDelay 1.3.6.1.4.1.164.3.1.6.7.1.1.44
Time in msec between CLID (Caller ID) signal detection on the line and CLID signal transmission. The CLID must be sent between ringing signals and the value of the delay is used for synchronizing the CLID transmission with the ringing signals transmission. Valid values: 0 - 3000 msec.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

ip2IfConnectivityMode 1.3.6.1.4.1.164.3.1.6.7.1.1.45
This MIB object shows whether to send Pings or OAM frames over the bundle.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER ping(2), oam(3)  

ip2IfClockSourceEnable 1.3.6.1.4.1.164.3.1.6.7.1.1.46
This MIB object defines whether this bundle can be a clock source.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

ip2IfNetworkType 1.3.6.1.4.1.164.3.1.6.7.1.1.47
This MIB object defines the network over which the Bundle PSN (Packet Switching Network)is transported. In Gmux2000: ipComprHeader indicates proprietary compressed IP header packets. mplsComprHeader indicates proprietary compressed MPLS header packets.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER notApplicable(1), ip(2), mplsEth(3), mac(4), ipComprHeader(5), mplsComprHeader(6), udp(7)  

ip2IfMplsRxLabelEnable 1.3.6.1.4.1.164.3.1.6.7.1.1.48
This MIB object defines whether there is user defined inner (Rx.) label for this Bundle.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

ip2IfMplsRxLabel 1.3.6.1.4.1.164.3.1.6.7.1.1.49
This MIB object defines the MPLS Rx. Label for this Bundle.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

ip2IfMplsTxLabelEnable 1.3.6.1.4.1.164.3.1.6.7.1.1.50
This MIB object defines whether there is user defined outer (Tx.) label for this Bundle.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

ip2IfMplsTxLabel 1.3.6.1.4.1.164.3.1.6.7.1.1.51
This MIB object defines the MPLS Tx. Label for this Bundle.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

ip2IfMplsTxExpBits 1.3.6.1.4.1.164.3.1.6.7.1.1.52
The MPLS Network priority (EXP bits) used for this bundle.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..7  

ip2IfMfcSpoofing 1.3.6.1.4.1.164.3.1.6.7.1.1.53
This MIB object defines whether the MFC (Multi Frequency Compelled) protocol spoofing will exist in the bundle. When the MFC Spoofing is used, the Local and Remote PBXs will send MFC Signaling to each other. The Vmuxes between the PBXs will send proprietary signaling to each other. They will however create and send MFC tones to their local PBX. The PBXs will not know that the actual signaling was not sent from a PBX but from a Vmux.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

ip2IfToneAckInterval 1.3.6.1.4.1.164.3.1.6.7.1.1.54
Time Interval in milli seconds from the time a Vmux sends tone/s to a local PBX until it receives an acknowledgement from this PBX. Valid values: 60...400 in steps of 20.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

ip2IfNextHopType 1.3.6.1.4.1.164.3.1.6.7.1.1.55
This MIB object defines the Bundle next Hop Address Type.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER notApplicable(1), ipAddress(2), macAddress(3)  

ip2IfNoiseLevelForVAD 1.3.6.1.4.1.164.3.1.6.7.1.1.56
This object defines the Level of Noise on the line, the Voice Activation Detector (VAD) will have to handle.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER low(2), high(3), off(4)  

ip2IfClockPreferences 1.3.6.1.4.1.164.3.1.6.7.1.1.57
The Clock preferences: accurateness (2) = Accurate clock is more important than Constant Delay. constantDelay (3)= Constant Delay is more important than Accurate clock .
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER accurateness(2), constantDelay(3)  

ip2IfConnectionMode 1.3.6.1.4.1.164.3.1.6.7.1.1.58
The Connection Mode: tdmOIpCe (2) = TDMOiP (CE) = Circuit Emulation. tdmOIpCv (3)= TDMOiP (CV) = Compressed Voice.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER tdmOIpCe(2), tdmOIpCv(3)  

ip2IfRingBack 1.3.6.1.4.1.164.3.1.6.7.1.1.59
Enables or disable Ring Back.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER disable(2), enable(3)  

ip2IfReversePolarity 1.3.6.1.4.1.164.3.1.6.7.1.1.60
Enables or disable Reverse polarity synthesis.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER disable(2), enable(3)  

ip2IfPulseMeter 1.3.6.1.4.1.164.3.1.6.7.1.1.61
Enables or disable Pulse metering synthesis.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER disable(2), enable(3)  

ip2IfPulseMeterFreq 1.3.6.1.4.1.164.3.1.6.7.1.1.62
Frequency of synthesized pulse metering for this bundle.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER rate12Khz(2), rate16Khz(3)  

ip2IfPulseMeterPeriod 1.3.6.1.4.1.164.3.1.6.7.1.1.63
Duration of synthesized pulse metering. current values are: 100-250.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

ip2IfOnHookDetect 1.3.6.1.4.1.164.3.1.6.7.1.1.64
Enables or disable immediate reaction to On-Hook bits from network in Ringing.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER disable(2), enable(3)  

ip2IfComfortNoiseGen 1.3.6.1.4.1.164.3.1.6.7.1.1.65
Enable or disable Comfort Noise Generation (CNG). When this parameter is enabled and no voice payload exists on the line for some time period during the call (moments of silence), the device will generate a soft background noise which assures the user that the connection is still alive (CNG). When this parameter is disabled and no voice payload exists on the line, absolute silence will be heard (Comfort Noise will not be generated).
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER disable(2), enable(3)  

ip2IfExitChannel 1.3.6.1.4.1.164.3.1.6.7.1.1.66
The channelized bundle that the voice bundle exits through. In Gmux2000 it is the ifIndex of the Channelized Bundle (sub-channel) that the Voice Bundle exits through. The ifIndex contains the Slot+Prt+Channelized Bundle No.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

ip2IfMaxVBDModemCalls 1.3.6.1.4.1.164.3.1.6.7.1.1.67
Maximum VBD modem calls for this bundle.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

ip2IfMaxRelayModemCalls 1.3.6.1.4.1.164.3.1.6.7.1.1.68
Maximum Relay modem calls for this bundle.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

ip2IfCustomToneFrequency 1.3.6.1.4.1.164.3.1.6.7.1.1.69
This is the frequency of the Custom Tone that is sent between PBXs in order to check that the line status is OK. When the Custom Tone Detection is enabled the device will not compress/decompress this tone. The custom tone that is received from the local PBX will be sent to the remote PBX with the same frequency it was received. When the Custom Tone Frequency is f1780Plus2000Hz (4), the device will not compress/decompress any tone with frequencies of 1780Hz or 2000 Hz.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER notApplicable(1), f1780Hz(2), f2000Hz(3), f1780Plus2000Hz(4)  

ip2IfVadMethod 1.3.6.1.4.1.164.3.1.6.7.1.1.70
Voice Activity Detection (VAD) method. proprietary (2) - non standard VAD based only on power measurement. It is very sensitive to background noise. internalITUT (3) - standard ITU-T VAD. It is a robust method.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER proprietary(2), internalITUT(3)  

ip2IfRxGain 1.3.6.1.4.1.164.3.1.6.7.1.1.71
Receive gain in dBm.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

ip2IfCallerIDType 1.3.6.1.4.1.164.3.1.6.7.1.1.72
Caller ID Type used by the DSP for this bundle. Bellcore type is used by the American method. V.23 type is used by the European method.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER bellcoreType1(2), v23(3)  

ip2IfPeerAddrType 1.3.6.1.4.1.164.3.1.6.7.1.1.73
This MIB object defines the peer Address Type.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER notApplicable(1), ipAddress(2), macAddress(3)  

ip2IfVbdRate 1.3.6.1.4.1.164.3.1.6.7.1.1.74
Voice Band Data (VBD) rate for this bundle.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER r64KbpsIn5msecIntervalsG711(2), r64KbpsIn10msecIntervalsG711(3), r32KbpsG726(4), r24KbpsG726(5)  

ip2IfDtmfDetection 1.3.6.1.4.1.164.3.1.6.7.1.1.75
Enable/Disable DTMF (Dual Tone Multi Frequency) detectors for this bundle.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

ip2IfNlpCutoffLevel 1.3.6.1.4.1.164.3.1.6.7.1.1.76
Non Linear Processor (NLP) Cutoff Level for this bundle. This parameter is used by the echo canceller. It is the maximum absolute linear PCM amplitude of the near-end signal that will cause the NLP module to be active and to mute low level residual echo & noisy surroundings.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

ip2IfDtdErlRatioCutoffQ3 1.3.6.1.4.1.164.3.1.6.7.1.1.77
The DTD ERL cutoff level is used in order to determine whether the near-end is talking or not. This parameter is used by the echo canceller when echo exists and there is voice with low volume on the line. DTD means Double Talk Detection. ERL means Echo Return Loss. It is the power difference [dB] between the far-end signal to the echo returned. The cutoff level is calculated for the value entering Q.3. This value will be divided by 2^3=8 in order to get the linear ratio.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

ip2IfCASRedundancy 1.3.6.1.4.1.164.3.1.6.7.1.1.78
Enable/Disable CAS signaling redundancy. This parameter is useful when there are problems with the network and applicable only for CAS signaling: E1-MF (G.732S) or E1-CRC-MF (G.732SCRC ). enable (3) - means that each packet containing CAS signaling will be triplicated into 3 packets. disable (2)- No redundancy will exist. Only 1 packet containing CAS will be transmitted.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

ip2IfBundleSensitivity 1.3.6.1.4.1.164.3.1.6.7.1.1.79
Denotes if the bundle is sensitive to delay in the network, or is sensitive to data errors in the network. Voice bundles are sensitive to delay; Non-voice bundles are sensitive to data errors.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER delaySensitive(2), dataSensitive(3)  

ip2IfOAMBundleIdent 1.3.6.1.4.1.164.3.1.6.7.1.1.80
Denotes if an OAM bundle is identified according to the Bundle Number (0x3fff), or according to the value of the first nibble in the VCCV control word sent in the frame. controlWord - applicable only when ip2IfProtocolVersion = v2(2). When ip2IfProtocolVersion = v1(1), only bundleNumber is applicable.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER bundleNumber(2), vccvCtrlWord(3)  

ip2IfMaxTxQueue 1.3.6.1.4.1.164.3.1.6.7.1.1.81
Max Tx Queue buffer size, measured in msec (milliseconds). Low buffer size may cause the buffer to overflow and discard packets in case of burst of packets on the network. High buffer size allows to store this burst and not lose packets.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

ip2IfMaxGprsTxQueue 1.3.6.1.4.1.164.3.1.6.7.1.1.82
Max GPRS Tx Queue buffer size, measured in msec (milliseconds). Low buffer size may cause the buffer to overflow and discard packets in case of burst of packets on the network. High buffer size allows to store this burst and not lose packets.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

ip2IfV23HD 1.3.6.1.4.1.164.3.1.6.7.1.1.83
This parameter shows whether V.23 Half Duplex Modem Protocol is enabled on the bundle.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

ip2IfModemProtocolMode 1.3.6.1.4.1.164.3.1.6.7.1.1.84
This octet string contains the mode of each Modem Protocol used on the bundle. For each protocol one octet will be used. Octet #1 will be used for V.22 Protocol. Octet #2, #3, #4... are reserved for future protocols. Octet #1 values: 0 - Not Applicable 1 - VBD: Voice Band Data. 2 - Relay: Pulse Code Modulated (PCM) data is sent via the bundle. For V.22: This MIB object is relevant only when ip2IfModemCalls = relay (4).
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING  

ip2IfCdisCngDetectionTime 1.3.6.1.4.1.164.3.1.6.7.1.1.85
When working with CDIS (Call DIScrimination method) or CNG (Comfort Noise Generation): The time in msec that the device will detect 1100Hz & 2100Hz signals on the line before switching to modem or fax. For Vmux: the values will be in steps of 10 msec.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

ip2IfSuperTandemBitMask 1.3.6.1.4.1.164.3.1.6.7.1.1.86
This MIB object enables controlling the Time Slot/Channel rate. Valid values: 1 - FF HEX Each BIT represents 1/8 of the TS. Example: 7E (0111 1110) means that 6/8 of the TS (the center ones) are masked and data will be Tx/Rx only through them. This MIB object is relevant only when Super Tandem is enabled.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING  

ip2IfVbdSwitchbackTime 1.3.6.1.4.1.164.3.1.6.7.1.1.87
Time in msec required for the DSP to switch back from VBD (Voice Band Data) to Voice. For Vmux: the values will be in steps of 30 msec.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

ip2IfCallerIdTxGain 1.3.6.1.4.1.164.3.1.6.7.1.1.88
The gain value in dBm units used for transmitting the Caller ID signal on the bundle.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

ip2IfCallerIdRxGain 1.3.6.1.4.1.164.3.1.6.7.1.1.89
The gain value in dBm units of the Caller ID signal received on the bundle.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

ip2IfUdpMuxMethod 1.3.6.1.4.1.164.3.1.6.7.1.1.90
This parameter determines according to which field the multiplexing is made: srcPort (2) - multiplexing according to the UDP Source Port (Dest=0x085e). This should be the default value, for backwards compatibility. destPort (3) - multiplexing according to the UDP Destination Port (standard multiplexing). The UDP Source and Destination ports' range is determined according to ip2IfUdpMuxMethod value: For srcPort (2) the range is 1-7000 For destPort (3) the range is 49152-65535.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER srcPort(2), destPort(3)  

ip2IfCallerIdDetection 1.3.6.1.4.1.164.3.1.6.7.1.1.91
Enable/Disable Caller ID Detection for this bundle.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

ip2IfWap 1.3.6.1.4.1.164.3.1.6.7.1.1.92
Enable/Disable WAP (Wireless Application Protocol) for this bundle. WAP allows users to access the internet from wireless devices.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

ip2IfTDMFrameBytes 1.3.6.1.4.1.164.3.1.6.7.2
The number of TDM bytes to be placed in a single IP frame payload.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

ip2IfTosValue 1.3.6.1.4.1.164.3.1.6.7.3
The TOS value to write in the IP frame.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

ip2IfVlanTagging 1.3.6.1.4.1.164.3.1.6.7.4
VLAN support. no - No support to VLAN. yes - 4 VLAN bytes will be added to the frame.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

ip2IfVlanID 1.3.6.1.4.1.164.3.1.6.7.5
VLAN ID.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

ip2IfVlanPriority 1.3.6.1.4.1.164.3.1.6.7.6
Frame priority.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

ip2IfStatTable 1.3.6.1.4.1.164.3.1.6.7.7
Channels (Bundles) Statistics Table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ip2IfStatEntry

ip2IfStatEntry 1.3.6.1.4.1.164.3.1.6.7.7.1
IP Statistics per bundle
Status: current Access: not-accessible
OBJECT-TYPE    
  Ip2IfStatEntry  

ip2IfStatChIndex 1.3.6.1.4.1.164.3.1.6.7.7.1.1
The channel index, which is actualy the bundle ID.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ip2IfStatSeqErrors 1.3.6.1.4.1.164.3.1.6.7.7.1.2
Number of events that the sequence number of an incoming Frame causes a transition from the 'sync' state to the 'out of sequence' state.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ip2IfStatBufUnderflows 1.3.6.1.4.1.164.3.1.6.7.7.1.3
Number of events that the buffer underflows. This records the count of the number of events the Receive (Eth to TDM) buffer underflows. In the case of a continuous underflow caused by a loss of Frame flow, a single buffer underflow should be counted.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ip2IfStatBufOverflows 1.3.6.1.4.1.164.3.1.6.7.7.1.4
Number of events that the buffer overflows. This records the count of the number of events the Receive (Eth to TDM) buffer overflows.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ip2IfStatTxOnTimeInterval 1.3.6.1.4.1.164.3.1.6.7.7.1.5
Number of frames that were transmitted due to time interval elapse. The user can choose to Tx the Frame when it reaches the Max size or when the packetizing time interval elapses. The packetizing time interval is the interval in msec that it takes to build a Max. size frame.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ip2IfStatTxOnMaxSize 1.3.6.1.4.1.164.3.1.6.7.7.1.6
Number of frames that were transmitted due to reaching max. frame size. The user can choose to Tx the Frame when it reaches the Max size or when the packetizing time interval elapses.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ip2IfStatRxSignaling 1.3.6.1.4.1.164.3.1.6.7.7.1.7
Number of signaling frames that were received.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ip2IfStatRxVoice 1.3.6.1.4.1.164.3.1.6.7.7.1.8
Number of voice frames that were received.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ip2IfStatRxHdlc 1.3.6.1.4.1.164.3.1.6.7.7.1.9
Number of HDLC frames that were received.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ip2IfStatTxSignaling 1.3.6.1.4.1.164.3.1.6.7.7.1.10
Number of signaling frames that were transmitted.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ip2IfStatTxVoice 1.3.6.1.4.1.164.3.1.6.7.7.1.11
Number of voice frames that were transmitted.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ip2IfStatTxHdlc 1.3.6.1.4.1.164.3.1.6.7.7.1.12
Number of HDLC frames that were transmitted.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ip2IfStatRdnFlip 1.3.6.1.4.1.164.3.1.6.7.7.1.13
Number of redundancy flips occured. This parameter counts only flips from this bundle to the other bundle in the redundancy couple.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ip2IfFarEndTdmStatus 1.3.6.1.4.1.164.3.1.6.7.7.1.14
This variable indicates the Status of the Far-End TDM Line. It contains failure state information. The variable is a bit map represented as a sum, therefore, it can represent multiple failures simultaneously. The farEndTdmNoDefect must be set if and only if no other flag is set. The various bit positions are: 1 farEndTdmNoDefect 2 farEndTdmAIS Alarm Indication Signal 4 farEndTdmRDI Remote Defect Indication
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..6  

ip2IfStatPsnTxFrames 1.3.6.1.4.1.164.3.1.6.7.7.1.15
Number of frames that were transmitted to PSN.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ip2IfStatPsnRxFrames 1.3.6.1.4.1.164.3.1.6.7.7.1.16
Number of frames that were recieved from PSN.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ip2IfStatMinJittBufLevel 1.3.6.1.4.1.164.3.1.6.7.7.1.17
The Minimum jitter buffer level (in msec).
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

ip2IfStatMaxJittBufLevel 1.3.6.1.4.1.164.3.1.6.7.7.1.18
The Maximum jitter buffer level (in msec).
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

ip2IfStatRecommendedJittBufSize 1.3.6.1.4.1.164.3.1.6.7.7.1.19
The Recommended jitter buffer Size (in msec). 0= not applicable.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

ip2IfStatPsnSeqErrors 1.3.6.1.4.1.164.3.1.6.7.7.1.20
Number of times that the sequence number of an incoming Frame indicates Loss of Frame or Out of order occured in PSN.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ip2IfStatPsnReorderFrames 1.3.6.1.4.1.164.3.1.6.7.7.1.21
Number of times that Frames had been reordered in PSN.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ip2IfStatMinRoundTripDelay 1.3.6.1.4.1.164.3.1.6.7.7.1.22
The minimum Round Trip delay (in msec). 0= not applicable.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

ip2IfStatMaxRoundTripDelay 1.3.6.1.4.1.164.3.1.6.7.7.1.23
The maximum Round Trip delay (in msec). 0= not applicable.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

ip2IfStatAvrRoundTripDelay 1.3.6.1.4.1.164.3.1.6.7.7.1.24
The avarage Round Trip delay (in msec). 0= not applicable.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

ip2IfStatFrameTrackDupDrop 1.3.6.1.4.1.164.3.1.6.7.7.1.25
The number of packets dropped due to being duplicated. (duplicated packet means a packet that has the same sequential number as a packet being received previously).
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ip2IfStatFrameTrackMissing 1.3.6.1.4.1.164.3.1.6.7.7.1.26
The number of packets that are missing. (Missing packet means an expected packet- according to the current sequential number - that was not received).
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ip2IfStatFrameTrackLongSerMiss 1.3.6.1.4.1.164.3.1.6.7.7.1.27
The longest series of consecutive missing sequential numbers. Missing sequential numbers represent missing packets that was expected to be received successively.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ip2IfStatTxMeasuredSilence 1.3.6.1.4.1.164.3.1.6.7.7.1.28
This object shows the percentage of Silence that was measured by the device for the current bundle in the transmitted payload. Relevant values: 0..100, 255. Default value is 50. 0 means that there is no silence on the line. 100 means that there is only silence. In this case, there might be no traffic. 255 - value for not applicable or unknown.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ip2IfStatRxMeasuredSilence 1.3.6.1.4.1.164.3.1.6.7.7.1.29
This object shows the percentage of Silence that was measured by the device for the current bundle in the received payload. Relevant values: 0..100, 255. Default value is 50. 0 means that there is no silence on the line. 100 means that there is only silence. In this case, there might be no traffic. 255 - value for not applicable or unknown.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ip2IfStatHdlcCrcErr 1.3.6.1.4.1.164.3.1.6.7.7.1.30
This counter indicates the number of received HDLC frames with CRC errors.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ip2IfStatHdlcAlignErr 1.3.6.1.4.1.164.3.1.6.7.7.1.31
This counter indicates the number of received HDLC frames with alignment errors.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ip2IfStatHdlcOversize 1.3.6.1.4.1.164.3.1.6.7.7.1.32
This counter indicates the number of received HDLC frames longer than 1470.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ip2IfStatHdlcUndersize 1.3.6.1.4.1.164.3.1.6.7.7.1.33
This counter indicates the number of received HDLC frames shorter than 4.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ip2IfStatHdlcAbort 1.3.6.1.4.1.164.3.1.6.7.7.1.34
This counter indicates the number of received HDLC frames with abort indication.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ip2IfStatRxCorrectFrames 1.3.6.1.4.1.164.3.1.6.7.7.1.35
Number of received correct frames.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ip2IfStatHdlcErroredFrames 1.3.6.1.4.1.164.3.1.6.7.7.1.36
Number of received errored HDLC frames.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ip2IfRateLimit 1.3.6.1.4.1.164.3.1.6.7.8
The maximum rate permitted to transfer via the network portin Mbps.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

ip2IfPortTable 1.3.6.1.4.1.164.3.1.6.7.9
Port Table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ip2IfPortEntry

ip2IfPortEntry 1.3.6.1.4.1.164.3.1.6.7.9.1
Application layer configuration per Port
Status: current Access: not-accessible
OBJECT-TYPE    
  Ip2IfPortEntry  

ip2IfPortIndex 1.3.6.1.4.1.164.3.1.6.7.9.1.1
The Port index, which is actualy the ifIndex.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ip2IfPortUsage 1.3.6.1.4.1.164.3.1.6.7.9.1.2
This parameter indicates the usage of the port (percents).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ip2IfPortMask 1.3.6.1.4.1.164.3.1.6.7.9.1.3
This parameter defines whether Agent will mask port's alarms and statistics or not.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), dontMask(2), mask(3)  

ip2IfPortTotalThroughput 1.3.6.1.4.1.164.3.1.6.7.9.1.4
This parameter indicates the total Throughput of the port in bps.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ip2IfCurrentStatTable 1.3.6.1.4.1.164.3.1.6.7.10
Channels (Bundles) Current Statistics Table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ip2IfCurrentStatEntry

ip2IfCurrentStatEntry 1.3.6.1.4.1.164.3.1.6.7.10.1
IP Current Statistics per bundle
Status: current Access: not-accessible
OBJECT-TYPE    
  Ip2IfCurrentStatEntry  

ip2IfCurrentStatSeqErrors 1.3.6.1.4.1.164.3.1.6.7.10.1.1
Number of seconds that the sequence number of an incoming Frame causes a transition from the 'sync' state to the 'out of sequence' state in the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ip2IfCurrentStatBufUnderflows 1.3.6.1.4.1.164.3.1.6.7.10.1.2
Number of seconds that the buffer underflows in the current interval. This records the count of the number of seconds the Receive (Eth to TDM) buffer underflows in the current interval. In the case of a continuous underflow caused by a loss of Frame flow, a single buffer underflow should be counted.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ip2IfCurrentStatBufOverflows 1.3.6.1.4.1.164.3.1.6.7.10.1.3
Number of seconds that the buffer overflows in the current interval. This records the count of the number of seonds the Receive (Eth to TDM) buffer overflows in the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ip2IfCurrentStatMaxDelayVar 1.3.6.1.4.1.164.3.1.6.7.10.1.4
The maximum deviation from the center of the buffer (in msec) for the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ip2IfCurrentStatMinJittBufLevel 1.3.6.1.4.1.164.3.1.6.7.10.1.5
The Minimum jitter buffer level (in msec) for the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

ip2IfCurrentStatMaxJittBufLevel 1.3.6.1.4.1.164.3.1.6.7.10.1.6
The Maximum jitter buffer level (in msec) for the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

ip2IfCurrentStatTxErrFrameSec 1.3.6.1.4.1.164.3.1.6.7.10.1.7
The number of seconds in which errored frames were transmitted during the current interval. The error may be one of the following: CRC error, Alignment error, Oversized frame, Undersized frame, Aborted frame.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ip2IfIntervalStatTable 1.3.6.1.4.1.164.3.1.6.7.11
Channels (Bundles) Interval Statistics Table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ip2IfIntervalStatEntry

ip2IfIntervalStatEntry 1.3.6.1.4.1.164.3.1.6.7.11.1
IP Interval Statistics per bundle
Status: current Access: not-accessible
OBJECT-TYPE    
  Ip2IfIntervalStatEntry  

ip2IfIntervalStatIndex 1.3.6.1.4.1.164.3.1.6.7.11.1.1
The Interval index, which is actualy the Interval number.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ip2IfIntervalStatSeqErrors 1.3.6.1.4.1.164.3.1.6.7.11.1.2
Number of seconds that the sequence number of an incoming Frame causes a transition from the 'sync' state to the 'out of sequence' state in the selected interval.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ip2IfIntervalStatBufUnderflows 1.3.6.1.4.1.164.3.1.6.7.11.1.3
Number of seconds that the buffer underflows in the selected interval. This records the count of the number of seconds the Receive (Eth to TDM) buffer underflows in the selected interval. In the case of a continuous underflow caused by a loss of Frame flow, a single buffer underflow should be counted.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ip2IfIntervalStatBufOverflows 1.3.6.1.4.1.164.3.1.6.7.11.1.4
Number of seconds that the buffer overflows in the selected interval. This records the count of the number of seconds the Receive (Eth to TDM) buffer overflows in the selected interval.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ip2IfIntervalStatMaxDelayVar 1.3.6.1.4.1.164.3.1.6.7.11.1.5
The maximum size of the buffer (in 10's of usec) in the selected interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ip2IfIntervalStatMinJittBufLevel 1.3.6.1.4.1.164.3.1.6.7.11.1.6
The Minimum jitter buffer level (in msec) for the selected interval.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

ip2IfIntervalStatMaxJittBufLevel 1.3.6.1.4.1.164.3.1.6.7.11.1.7
The Maximum jitter buffer level (in msec) for the selected interval.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

ip2IfIntervalStatTxErrFrameSec 1.3.6.1.4.1.164.3.1.6.7.11.1.8
The number of seconds in which errored frames were transmitted during the selected interval. The error may be one of the following: CRC error, Alignment error, Oversized frame, Undersized frame, Aborted frame.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ip2IfLogEvents 1.3.6.1.4.1.164.3.1.6.7.12
This parameter defines whether all Jitter Buffer and Sequence Number events will enter to Log File, or enter those events to Log file in one minute steps.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), all(2), oneMinStep(3)  

ip2IfEthSwitchMode 1.3.6.1.4.1.164.3.1.6.7.13
This parameter defines whether Eth Switch is in VLAN Tagged mode.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), unTagged(2), tagged(3)  

alarmStatusTrap 1.3.6.1.4.1.164.6.1.3.0.5
The trap is sent whenever there is a transition from a no alarm state to a state with at least one active alarm.
Status: current Access: read-write
NOTIFICATION-TYPE    

systemTrap 1.3.6.1.4.1.164.6.1.3.0.6
This trap alerts of major problems in the device.
Status: current Access: read-write
NOTIFICATION-TYPE    

alarmLOS 1.3.6.1.4.1.164.6.1.3.0.7
This trap indicates Loss Of Signal.
Status: current Access: read-write
NOTIFICATION-TYPE    

alarmLOF 1.3.6.1.4.1.164.6.1.3.0.8
This trap indicates Loss Of Frame.
Status: current Access: read-write
NOTIFICATION-TYPE    

channelOperStatusTrap 1.3.6.1.4.1.164.6.1.3.0.9
This trap is sent upon any change in one or more channels.
Status: current Access: read-write
NOTIFICATION-TYPE    

alarmAIS 1.3.6.1.4.1.164.6.1.3.0.10
This trap indicates AIS.
Status: current Access: read-write
NOTIFICATION-TYPE    

alarmRDI 1.3.6.1.4.1.164.6.1.3.0.11
This trap indicates RDI.
Status: current Access: read-write
NOTIFICATION-TYPE    

alarmFEBE 1.3.6.1.4.1.164.6.1.3.0.12
This trap indicates FEBE.
Status: current Access: read-write
NOTIFICATION-TYPE    

localConnStatusTrap 1.3.6.1.4.1.164.6.1.3.0.13
This trap is sent upon a change in Local connectivity of Bundle connection.
Status: current Access: read-write
NOTIFICATION-TYPE    

remoteConnStatusTrap 1.3.6.1.4.1.164.6.1.3.0.14
This trap is sent upon a change in Remote connectivity of Bundle connection.
Status: current Access: read-write
NOTIFICATION-TYPE    

bundleConnectionStatusTrap 1.3.6.1.4.1.164.6.1.3.0.15
This trap is sent upon any change in the connectivity status of a Bundle (ip2IfOperStatus). The ifAlias index is the ifIndex of the bundle that its status has been changed.
Status: current Access: read-write
NOTIFICATION-TYPE    

broadbandIf 1.3.6.1.4.1.164.3.1.6.8
OBJECT IDENTIFIER    

bdbandConfig 1.3.6.1.4.1.164.3.1.6.8.1
OBJECT IDENTIFIER    

prtPhyPerfHistory 1.3.6.1.4.1.164.3.1.6.8.2
OBJECT IDENTIFIER    

prtBdbandIndTable 1.3.6.1.4.1.164.3.1.6.8.1.1
The Indication Signal table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtBdbandIndEntry

prtBdbandIndEntry 1.3.6.1.4.1.164.3.1.6.8.1.1.1
An entry in the Indication Signal table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtBdbandIndEntry  

prtBdbandCnfgIdx 1.3.6.1.4.1.164.3.1.6.8.1.1.1.1
This object indicates the Idx of the Agent Cnfg the following objects refer. 255=Temporary Cnfg (when relevant, Set is done only to this configuration). For Agents that support only one configuration, this object will be constant=1.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

prtBdbandIdx 1.3.6.1.4.1.164.3.1.6.8.1.1.1.2
This object indicates a unique port or interface number. For numbering, see product's spec. For some products, the numbering can equal ifIndex.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtBdbandIndSig 1.3.6.1.4.1.164.3.1.6.8.1.1.1.3
This object indicates a unique Indication Signal. ais(1) = AIS = Alarm Indication Signal. rdi(2) = RDI = Remote Defect Indication.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER ais(1), rdi(2), aisAndRdi(3)  

prtBdbandIndEvent 1.3.6.1.4.1.164.3.1.6.8.1.1.1.4
This object indicates a unique Event that can cause the Indication Signal. slm(2) = SLM = Signal Label Mismatch eed(4) = EED = Excessive Error Defect pathTrace(5) = the end-to-end source/destination of information is wrong. lom(6) = LOM = Loss of Multiframe. lop(7) = LOP = Loss of Pointer. slu(8) = SLU = Signal Label Unequipped.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), slm(2), fail(3), eed(4), pathTrace(5), lom(6), lop(7), slu(8)  

prtBdbandIndSigEnable 1.3.6.1.4.1.164.3.1.6.8.1.1.1.5
This object allows user to define if the event specified by prtBdbandIndEvent will cause creation of the Indication Signal specified by prtBdbandIndSig or not. disable - will not enable causing the signal enable - will enable causing the signal.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

prtBdbandRowStatus 1.3.6.1.4.1.164.3.1.6.8.1.1.1.6
Creation/Deletion of rows in the table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

prtPhyConfigTable 1.3.6.1.4.1.164.3.1.6.8.1.2
The Phy Config table. Used now for Phy25.6 Mbps.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtPhyConfigEntry

prtPhyConfigEntry 1.3.6.1.4.1.164.3.1.6.8.1.2.1
An entry in the Phy Config table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtPhyConfigEntry  

prtPhyTimeElapsed 1.3.6.1.4.1.164.3.1.6.8.1.2.1.1
The number of seconds that have elapsed since the beginning of the current error-measurement period.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..899  

prtPhyValidIntervals 1.3.6.1.4.1.164.3.1.6.8.1.2.1.2
The number of previous intervals for which valid data was collected. The value will be 96 unless the interface was brought online within the last 24 hours, in which case the value will be the number of complete 15 minute since the interface has been online.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..96  

prtPhyCurrentTable 1.3.6.1.4.1.164.3.1.6.8.2.1
The 25.6 Mbps Section/Line Current table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtPhyCurrentEntry

prtPhyCurrentEntry 1.3.6.1.4.1.164.3.1.6.8.2.1.1
An entry in the 25.6 Mbps Line Current table. ifIndex of the line 25.6 Mbps layer of type 25.6 Mbps.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtPhyCurrentEntry  

prtPhyCurrentLOS 1.3.6.1.4.1.164.3.1.6.8.2.1.1.1
The counter associated with the number of Loss Of Sync seconds, encountered by a 25.6 Mbps interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtPhyCurrentLSV 1.3.6.1.4.1.164.3.1.6.8.2.1.1.2
The counter associated with the number of Line symbol violation seconds, encountered by a 25.6 Mbps interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtPhyCurrentUAS 1.3.6.1.4.1.164.3.1.6.8.2.1.1.3
The counter associated with the number of UAS encountered by a 25.6 Mbps interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtPhyCurrentSES 1.3.6.1.4.1.164.3.1.6.8.2.1.1.4
The counter associated with the number of SES encountered by a 25.6 Mbps interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtPhyCurrentES 1.3.6.1.4.1.164.3.1.6.8.2.1.1.5
The number of Errored Seconds, encountered by a 25.6 Mbps interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtPhyCurrentStatus 1.3.6.1.4.1.164.3.1.6.8.2.1.1.6
The statuses of the current interval: 0 - O.K. 1 - The link has been switched by a redundancy mechanism. 2 - Module is in/out. 4 - Empty - card is out.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(4)  

prtPhyCurrentLOF 1.3.6.1.4.1.164.3.1.6.8.2.1.1.7
The number of Loss of Frames, encountered by an interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtPhyIntervalTable 1.3.6.1.4.1.164.3.1.6.8.2.2
The Line Interval table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtPhyIntervalEntry

prtPhyIntervalEntry 1.3.6.1.4.1.164.3.1.6.8.2.2.1
An entry in the 25.6 Mbps Line Interval table. ifIndex of the line 25.6 Mbps layer of type 25.6 Mbps.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtPhyIntervalEntry  

prtPhyIntervalNumber 1.3.6.1.4.1.164.3.1.6.8.2.2.1.1
A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..96  

prtPhyIntervalLOS 1.3.6.1.4.1.164.3.1.6.8.2.2.1.2
The counter associated with the number of Loss Of Sync seconds , encountered by a 25.6 Mbps interface in one of the previous 96, individual 15 minute intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtPhyIntervalLSV 1.3.6.1.4.1.164.3.1.6.8.2.2.1.3
The counter associated with the number of line symbol violation seconds , encountered by a 25.6 Mbps interface in one of the previous 96, individual 15 minute intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtPhyIntervalUAS 1.3.6.1.4.1.164.3.1.6.8.2.2.1.4
The counter associated with the number of UAS encountered by a 25.6 Mbps interface in one of the previous 96, individual 15 minute intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtPhyIntervalSES 1.3.6.1.4.1.164.3.1.6.8.2.2.1.5
The counter associated with the number of SES encountered by a 25.6 Mbps interface in one of the previous 96, individual 15 minute intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtPhyIntervalES 1.3.6.1.4.1.164.3.1.6.8.2.2.1.6
The number of Errored Seconds, encountered by a 25.6 Mbps interface in one of the previous 96, individual 15 minute intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtPhyIntervalStatus 1.3.6.1.4.1.164.3.1.6.8.2.2.1.7
The statuses of the current interval: 0 - O.K. 1 - The link has been switched by a redundancy mechanism. 2 - Module is in/out. 4 - Empty - card is out.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(4)  

prtPhyIntervalLOF 1.3.6.1.4.1.164.3.1.6.8.2.2.1.8
The number of Loss of Frames, encountered by an interface in one of the previous 96, individual 15 minute intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

webranger 1.3.6.1.4.1.164.11.7.2
OBJECT IDENTIFIER    

wrSysConfig 1.3.6.1.4.1.164.11.7.2.1
OBJECT IDENTIFIER    

wrBraodcastCtrlCmd 1.3.6.1.4.1.164.11.7.2.1.1
This parameter is a command to the webranger CPU. It enables blocking or forwarding broadcast frames, which may cause a trigger to a connection. block (1) - blocks the broadcast frames. forward (2) - forwards the broadcast frames. blockLinkPropagation (3) - blocks the broadcast frames to the links, tx to the LAN.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER block(1), forward(2), blockLinkPropagation(3)  

wrFrSelfLearningMode 1.3.6.1.4.1.164.11.7.2.1.2
This parameter enables the webranger to learn the DLCi's configuration and maintanance protocol. off - will get the configuration by setting it. on - disables configuration and start self learning.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

wrGratuitousArp 1.3.6.1.4.1.164.11.7.2.1.3
This parameter enables/disables the Gratuitous ARP feature. When enabled, the feature means: when receiving ARP with sender's Source IP Address that already exists in the ARP table - replace MAC Address with sender's Source MAC Address.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(2), enable(3)  

wrIpRouterInfo 1.3.6.1.4.1.164.11.7.2.2
OBJECT IDENTIFIER    

wrConfigIpDhcp 1.3.6.1.4.1.164.11.7.2.2.1
OBJECT IDENTIFIER    

wrConfigIpDNS 1.3.6.1.4.1.164.11.7.2.2.2
OBJECT IDENTIFIER    

wrDhcpAction 1.3.6.1.4.1.164.11.7.2.2.1.1
Activating (disable/enable) DHCP server operation. Since DHCP Server and DHCP Relay cannot reside in same device, DHCP Relay may be enabled (per interface), only if server action is disabled. For some devices, this object is used in order to enable/disable the DHCP Client. See device SDS.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(2), enable(3)  

wrDhcpTable 1.3.6.1.4.1.164.11.7.2.2.1.2
A list of DHCP entries. The number of entries is up to DHCP current entries, according to the WEBRANger model.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WrDhcpEntry

wrDhcpEntry 1.3.6.1.4.1.164.11.7.2.2.1.2.1
DHCP parameters per entry of the DHCP table.
Status: current Access: not-accessible
OBJECT-TYPE    
  WrDhcpEntry  

wrDhcpLowIpAddress 1.3.6.1.4.1.164.11.7.2.2.1.2.1.1
DHCP Low Ip Address.
Status: current Access: read-create
OBJECT-TYPE    
  IpAddress  

wrDhcpHighIpAddress 1.3.6.1.4.1.164.11.7.2.2.1.2.1.2
DHCP High Ip Address.
Status: current Access: read-create
OBJECT-TYPE    
  IpAddress  

wrDhcpIpMaskAddress 1.3.6.1.4.1.164.11.7.2.2.1.2.1.3
IP mask Address.
Status: current Access: read-create
OBJECT-TYPE    
  IpAddress  

wrDhcpDefaultGateway 1.3.6.1.4.1.164.11.7.2.2.1.2.1.4
Default Gateway's IP Address.
Status: current Access: read-create
OBJECT-TYPE    
  IpAddress  

wrDhcpPrimaryDNS 1.3.6.1.4.1.164.11.7.2.2.1.2.1.5
Primary DNS.
Status: current Access: read-create
OBJECT-TYPE    
  IpAddress  

wrDhcpSecondaryDNS 1.3.6.1.4.1.164.11.7.2.2.1.2.1.6
Secondary DNS.
Status: current Access: read-create
OBJECT-TYPE    
  IpAddress  

wrDhcpInterface 1.3.6.1.4.1.164.11.7.2.2.1.2.1.7
The IP addresse allocation is done according to the interface type from which the DHCP request arrives.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER all(1), lan1(2), lan2(3), anyLan(4), wan(5)  

wrDhcpRowStatus 1.3.6.1.4.1.164.11.7.2.2.1.2.1.8
This attribute allows to create/delete a row in this table. For creating a row, the NMS should set wrDhcpRowStatus.id = active(1). For destroying a row, the NMS should set: wrDhcpStatus.id = destroy(6). Only rows with status active(1) are relevant. The only possible supported RowStatus vaules are active (1) and destroy (6).
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

wrDhcpIpAddressLeaseTime 1.3.6.1.4.1.164.11.7.2.2.1.2.1.9
Allocated IP Address lease time in seconds. A zero value specifies no time limitation.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

wrDhcpPoolName 1.3.6.1.4.1.164.11.7.2.2.1.2.1.10
DHCP pool name - string with max length of 10 characters
Status: current Access: read-create
OBJECT-TYPE    
  SnmpAdminString Size(1..10)  

wrDhcpTftpServerIp 1.3.6.1.4.1.164.11.7.2.2.1.2.1.11
DHCP pool - TFTP-server IP Address.
Status: current Access: read-create
OBJECT-TYPE    
  IpAddress  

wrDhcpConfigFileName 1.3.6.1.4.1.164.11.7.2.2.1.2.1.12
TFTP-name of the configuration File Name for DHCP pool.
Status: current Access: read-create
OBJECT-TYPE    
  SnmpAdminString Size(1..50)  

dhcpPoolAllocTable 1.3.6.1.4.1.164.11.7.2.2.1.3
A list of DHCP Pool Allocation entries. Each entry (row) consist of a single IP Address belonging to DHCP pool whose lowest IP address is dhcpPoolAllocLowIpAddress. This IP address may be offered for leasing, or may already be leased (in use) by Host it's MacAddress is dhcpPoolAllocMacAddress. Time left for leasing period is indicated by dhcpPoolAllocTimeLeft. All posible statuses of IP address are indicated and controlled by dhcpPoolAllocFlags
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DhcpPoolAllocEntry

dhcpPoolAllocEntry 1.3.6.1.4.1.164.11.7.2.2.1.3.1
DHCP Pool Allocation parameters per entry of the DHCP Pool Allocation table.
Status: current Access: not-accessible
OBJECT-TYPE    
  DhcpPoolAllocEntry  

dhcpPoolAllocLowIpAddress 1.3.6.1.4.1.164.11.7.2.2.1.3.1.1
Lowest IP address of this pool, value eqaul to wrDhcpLowIpAddress for the pool.
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

dhcpPoolAllocLeasingIpAddress 1.3.6.1.4.1.164.11.7.2.2.1.3.1.2
Single IP Address belonging to dhcp pool whose Lowest Ip Address is dhcpPoolAllocLowIpAddress. This IP address may be offered for leasing or may be leased by Host its MacAddress is dhcpPoolAllocMacAddress. All posible statuses of IP address are indicated by dhcpPoolAllocFlags
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

dhcpPoolAllocMacAddress 1.3.6.1.4.1.164.11.7.2.2.1.3.1.3
MAC Address to which the IP address has been leased
Status: current Access: read-only
OBJECT-TYPE    
  MacAddress  

dhcpPoolAllocTimeLeft 1.3.6.1.4.1.164.11.7.2.2.1.3.1.4
IP address leasing time left in seconds
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

dhcpPoolAllocFlags 1.3.6.1.4.1.164.11.7.2.2.1.3.1.5
These flags indicates status of each IP address. User may change value to free, via dhcpPoolAllocFreeCmd
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), free(2), inUse(3), offered(4), forbidden(5)  

dhcpPoolAllocFreeCmd 1.3.6.1.4.1.164.11.7.2.2.1.3.1.6
Setting this attribute to On (3), will enforce the agent to Free this entry. The Agent will change the value of this MIB object to off(2) automatically, after performing the command. Setting this object to off(2), will do nothing
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

dhcpRelayTable 1.3.6.1.4.1.164.11.7.2.2.1.4
A list of DHCP relay entries.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DhcpRelayEntry

dhcpRelayEntry 1.3.6.1.4.1.164.11.7.2.2.1.4.1
DHCP Relay parameters per entry of the DHCP relay table.
Status: current Access: not-accessible
OBJECT-TYPE    
  DhcpRelayEntry  

dhcpRelayAction 1.3.6.1.4.1.164.11.7.2.2.1.4.1.1
Setting this attribute to enable (3), will enable DHCP Relay action for this interface (Only if DHCP Server is disabled for device - wrDhcpAction=disable). dhcpRelayServerIpAddressaddress should not be 0.0.0.0 when enable is set
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(2), enable(3)  

dhcpRelayServerIpAddress 1.3.6.1.4.1.164.11.7.2.2.1.4.1.2
DHCP Server IP Address.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

dhcpRelayMaxHop 1.3.6.1.4.1.164.11.7.2.2.1.4.1.3
Maximum number of hops till DHCP Server. upper limit is 16 hops
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

wrDhcpPort 1.3.6.1.4.1.164.11.7.2.2.1.5
This parameter defines the port that DHCP flow will be actiavted.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), all(2), outOfBand(3), lan1(4), lan2(5)  

dhcpClientTable 1.3.6.1.4.1.164.11.7.2.2.1.6
A list of DHCP client entries.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DhcpClientEntry

dhcpClientEntry 1.3.6.1.4.1.164.11.7.2.2.1.6.1
DHCP Client parameters per entry of the DHCP Client table.
Status: current Access: not-accessible
OBJECT-TYPE    
  DhcpClientEntry  

dhcpClientAction 1.3.6.1.4.1.164.11.7.2.2.1.6.1.1
This parameter default value is enable(3). Setting this attribute to disable (2), will disable DHCP Client action for this interface. This parameter can be changed to disable (2) only (it cannot be changed from disable to enable).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(2), enable(3)  

dhcpClientServerIpAddress 1.3.6.1.4.1.164.11.7.2.2.1.6.1.2
DHCP Server IP Address.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

dhcpClientLeaseExpirationTime 1.3.6.1.4.1.164.11.7.2.2.1.6.1.3
This parameter holds the time (in minutes) left until lease expiration.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

dhcpClientStatus 1.3.6.1.4.1.164.11.7.2.2.1.6.1.4
This parametr displays the DHCP status.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

dhcpIfClientTable 1.3.6.1.4.1.164.11.7.2.2.1.7
DHCP client entries for each Interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DhcpIfClientEntry

dhcpIfClientEntry 1.3.6.1.4.1.164.11.7.2.2.1.7.1
DHCP Clients per entry of the DHCP Interface Client table.
Status: current Access: not-accessible
OBJECT-TYPE    
  DhcpIfClientEntry  

dhcpIfClientIpAddress 1.3.6.1.4.1.164.11.7.2.2.1.7.1.2
DHCP Client IP Address.
Status: current Access: read-create
OBJECT-TYPE    
  IpAddress  

dhcpIfClientRowStatus 1.3.6.1.4.1.164.11.7.2.2.1.7.1.3
The row status used for creating, modifying, and deleting instances of the columnar objects in the dhcpIfClientTable. For Vmux Devices, it will be possible only to Delete instances. The addition of Clients will be done automatically by the Server according to Network messages that are sent by the Clients; not via SNMP. In order to Delete a Client, this MIB object should be set to: destroy (6).
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

dhcpServerAction 1.3.6.1.4.1.164.11.7.2.2.1.8
This variable enables the operator to perform one of the specified actions on the Server. deleteAllClients (3) is an option that is used for a device functioning as a server. It will remove all the clients from all the interfaces of the device. When the operation is complete, the agent will return a noOp (2) value.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noOp(2), deleteAllClients(3)  

wrDNSRelayAction 1.3.6.1.4.1.164.11.7.2.2.2.1
When Enabled, device will act as a DNS Relay: whenever the device receives a DNS request from its host, it will forward it to the DNS server as if the request was initiated by the device itself. The reply from the DNS server is forwarded by the device to the host as if the device was answering the request.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

wrConfigIpxRouterInfo 1.3.6.1.4.1.164.11.7.2.3
OBJECT IDENTIFIER    

wrAutoLearnLanIpxNets 1.3.6.1.4.1.164.11.7.2.3.1
Activating (disable/enable) the auto-learn operation.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(2), enable(3)  

wrLanIpxNetTable 1.3.6.1.4.1.164.11.7.2.3.2
Lan IPX nets Table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WrLanIpxNetEntry

wrLanIpxNetEntry 1.3.6.1.4.1.164.11.7.2.3.2.1
IPX Nets per frame type & LAN port. The table entries will be created by the agent
Status: current Access: not-accessible
OBJECT-TYPE    
  WrLanIpxNetEntry  

wrLanifIndex 1.3.6.1.4.1.164.11.7.2.3.2.1.1
LAN port ifIndex.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

wrLanIpxFrameType 1.3.6.1.4.1.164.11.7.2.3.2.1.2
Frame Type
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER t8023(1), ethernet(2), t8022(3), snap(4)  

wrIpxNetAddress 1.3.6.1.4.1.164.11.7.2.3.2.1.3
Net address per Frame Type & LAN port.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

wrDialInIpxNet 1.3.6.1.4.1.164.11.7.2.3.3
Net address through a link.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

ripSapIfConfTable 1.3.6.1.4.1.164.11.7.2.3.4
A list of Interfaces which require separate configuration in RIP/SAP.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RipSapIfConfEntry

ripSapIfConfEntry 1.3.6.1.4.1.164.11.7.2.3.4.1
A Single Routing Domain in a single Subnet.
Status: current Access: not-accessible
OBJECT-TYPE    
  RipSapIfConfEntry  

ripSapIfConfIfIndex 1.3.6.1.4.1.164.11.7.2.3.4.1.1
The interface ifIndex.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ripSapIfConfMode 1.3.6.1.4.1.164.11.7.2.3.4.1.2
The ifIndex RIP/SAP mode.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER off(1), on(2)  

ripSapIfConfStatus 1.3.6.1.4.1.164.11.7.2.3.4.1.3
This attribute allows to create/delete a row in this table. For creating a row, the NMS should set ripSapIfConfStatus.id1 = active(1). For destroying a row, the NMS should set: ripSapIfConfStatus.id1 = destroy(6). Only rows with status active(1) are relevant. The only possible supported RowStatus vaules are active (1) and destroy (6).
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

wrInterface 1.3.6.1.4.1.164.11.7.2.4
OBJECT IDENTIFIER    

wrIpAddressTable 1.3.6.1.4.1.164.11.7.2.4.1
Link IP addresses Table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WrIpAddressEntry

wrIpAddressEntry 1.3.6.1.4.1.164.11.7.2.4.1.1
Ip Address per Link
Status: current Access: not-accessible
OBJECT-TYPE    
  WrIpAddressEntry  

wrIpIfIndex 1.3.6.1.4.1.164.11.7.2.4.1.1.1
Port interface index.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

wrIpAddress 1.3.6.1.4.1.164.11.7.2.4.1.1.2
Link IP Address.
Status: current Access: read-create
OBJECT-TYPE    
  IpAddress  

wrIpMask 1.3.6.1.4.1.164.11.7.2.4.1.1.3
Link IP mask Address.
Status: current Access: read-create
OBJECT-TYPE    
  IpAddress  

wrIpRowStatus 1.3.6.1.4.1.164.11.7.2.4.1.1.4
This attribute allows to create/delete a row in this table. For creating a row, the NMS should set wrIpRowStatus.id1 = active(1). For destroying a row, the NMS should set: wrIpRowStatus.id1 = destroy(6). Only rows with status active(1) are relevant. The only possible supported RowStatus vaules are active (1) and destroy (6).
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

wrSpoofingTable 1.3.6.1.4.1.164.11.7.2.4.2
Spoofing Table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WrSpoofingEntry

wrSpoofingEntry 1.3.6.1.4.1.164.11.7.2.4.2.1
Spoofing per Link
Status: current Access: not-accessible
OBJECT-TYPE    
  WrSpoofingEntry  

wrSpoofingIfIndex 1.3.6.1.4.1.164.11.7.2.4.2.1.1
Port interface index.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

wrSpoofingAction 1.3.6.1.4.1.164.11.7.2.4.2.1.2
Spoofing action is applied by bit code: enable : bit 0 set (disable: bit 0 is 0) keepAlive : bit 1 ... : bit 2 and so on. For the above example, to set spoofing to keepAlive action, the object's value will be 3 = [ 2**0 + 2**1 ] Only the Remote WEBRANger will accept this object ! -------
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

wrSpoofingAgingStation 1.3.6.1.4.1.164.11.7.2.4.2.1.3
Aging time of stations list, in min. The agent 'translates' the time entered in minutes, to 10 min. resolution, as follows: 1..10 min - 10 min 11..20 min - 20 min and so on... 0 is not a valid value. Only the Remote WEBRANger will accept this object ! ----------------
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

wrSpoofingRowStatus 1.3.6.1.4.1.164.11.7.2.4.2.1.4
This attribute allows to create/delete a row in this table. For creating a row, the NMS should set wrSpoofingRowStatus.id1 = active(1). For destroying a row, the NMS should set: wrSpoofingRowStatus.id1 = destroy(6). Only rows with status active(1) are relevant. The only possible supported RowStatus vaules are active (1) and destroy (6).
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

wrLanIfTable 1.3.6.1.4.1.164.11.7.2.4.3
Link IP addresses Table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WrLanIfEntry

wrLanIfEntry 1.3.6.1.4.1.164.11.7.2.4.3.1
Ip Address per Link
Status: current Access: not-accessible
OBJECT-TYPE    
  WrLanIfEntry  

wrLanIfIndex 1.3.6.1.4.1.164.11.7.2.4.3.1.1
Port interface index.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

wrLanBridgeRouterMode 1.3.6.1.4.1.164.11.7.2.4.3.1.2
This parameter indicates whether the link is Bridge or Router and specifies the Router's type.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), bridge(2), ipRouter(3), ipxRouter(4), ipAndIpxRouter(5), bRouter(6), ipBrouter(7), ipxBrouter(8), ipAndIpxBrouter(9), bridgeAndStp(10)  

wrLanIfState 1.3.6.1.4.1.164.11.7.2.4.3.1.3
The LAN is disabled or enabled. For LAN 2 it can be also 'redundancy'.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(2), enable(3), redundancy(4)  

wrLanIfRdnTimeout 1.3.6.1.4.1.164.11.7.2.4.3.1.4
LAN Redundancy Timeout in seconds. Applicable when wrLanIfState=redundancy.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

wrSyncCnfgTable 1.3.6.1.4.1.164.11.7.2.4.4
Configuration table for Async interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WrSyncCnfgEntry

wrSyncCnfgEntry 1.3.6.1.4.1.164.11.7.2.4.4.1
Configuration table
Status: current Access: not-accessible
OBJECT-TYPE    
  WrSyncCnfgEntry  

wrSyncIfIndex 1.3.6.1.4.1.164.11.7.2.4.4.1.1
Sync interface index.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

wrSyncClkMode 1.3.6.1.4.1.164.11.7.2.4.4.1.2
Clock Mode.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), manual(2), program(3)  

wrSyncClkRate 1.3.6.1.4.1.164.11.7.2.4.4.1.3
Clock Rate in. Rate can be changed if Clock Mode is Program only.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), r16(2), r32(3), r48(4), r64(5), r96(6), r128(7), r256(8), r768(9)  

wrFrCnfgTable 1.3.6.1.4.1.164.11.7.2.4.5
Configuration table for Fr parameters that do not exist in RFC2115.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WrFrCnfgEntry

wrFrCnfgEntry 1.3.6.1.4.1.164.11.7.2.4.5.1
Configuration entry for Fr parameters that do not exist in RFC2115.
Status: current Access: not-accessible
OBJECT-TYPE    
  WrFrCnfgEntry  

wrFrDlciLearningMode 1.3.6.1.4.1.164.11.7.2.4.5.1.1
This parameter enables the webranger to learn the DLCi's configuration and maintanance protocol for the current interface. off - the WR will read the user's configuration for this interface. on - the WR will begin self learning of the current interface's maintanance protocol and DLCIs.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

wrFrCllmMessages 1.3.6.1.4.1.164.11.7.2.4.5.1.2
This parameter enables/disables the Webranger to Tx/Rx CLLM (Consolidated Link Layer Management) messages via DLCI 1023. The CLLM messages are link layer control messages. They can be used for example in cases of congestion. The CLLM message contains a code for cause of congestion and list of all DLCIs that should act to reduce data transmission.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(2), enable(3)  

dacsMux 1.3.6.1.4.1.164.3.3
OBJECT IDENTIFIER    

systemDacsMux 1.3.6.1.4.1.164.3.3.1
OBJECT IDENTIFIER    

mdlDacsMux 1.3.6.1.4.1.164.3.3.2
OBJECT IDENTIFIER    

prtDacsMux 1.3.6.1.4.1.164.3.3.3
OBJECT IDENTIFIER    

genDacsMux 1.3.6.1.4.1.164.3.3.4
OBJECT IDENTIFIER    

sysSa 1.3.6.1.4.1.164.3.3.1.1
OBJECT IDENTIFIER    

sysHub 1.3.6.1.4.1.164.3.3.1.2
OBJECT IDENTIFIER    

sysStatus 1.3.6.1.4.1.164.3.3.1.3
OBJECT IDENTIFIER    

sysCurrentAlr 1.3.6.1.4.1.164.3.3.1.4
OBJECT IDENTIFIER    

sysBufferAlr 1.3.6.1.4.1.164.3.3.1.5
OBJECT IDENTIFIER    

sysConfig 1.3.6.1.4.1.164.3.3.1.6
OBJECT IDENTIFIER    

sysDbase 1.3.6.1.4.1.164.3.3.1.7
OBJECT IDENTIFIER    

sysSaSwchStatus 1.3.6.1.4.1.164.3.3.1.1.1
This object indicates the status of the switches on the SA unit. Each switch is represented by a bit. The status is a sum of 2**n, according to the bits. For SMODs products see modem's specification. For DXC product see the following: There are 4 switches: bit 0 SP-PAR (LSB) '1' - Default parameters bit 1 PSWRD '1' - Password=default '0' - Password=user selected bit 2 DB-INIT '1' - DB initiated with default '0' - DB initiated with NVRAM contents bit 3 PC-SP (MSB) '1' - Management by terminal only '0' - Management by NMS Example: If SP-PAR and PSWRD bits are set ('1'), the value will be 3 (2**1 + 2**0). When the status of the switches is unknown, the value of this object will be 255.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sysSaSwRevision 1.3.6.1.4.1.164.3.3.1.1.2
This object indicates the Software revision of the system.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

sysSaHwVersion 1.3.6.1.4.1.164.3.3.1.1.3
This object indicates the Hardware version of the system.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

sysSaPorts 1.3.6.1.4.1.164.3.3.1.1.4
This object indicates the ports that are present in the system. Each possible port is represented by a bit. The value of this object is a sum of 2**n, n=number of bits. '1' - means that the port exists '0' - means that the port does not exist For detailed bit assignment, see product's spec. Bit 0 = LSB When this object is not relevant, the value will be 0. In some cases, this object may represent ports configuration of the system AND its far-end unit.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sysSaReadSwch 1.3.6.1.4.1.164.3.3.1.1.5
This object indicates wether the configuration will be read from the DIP switches on the SA (stand alone) unit. Each switch is represented by a bit. If the bit is 1: the configuration will be read from the HW switch position. If the bit is 0: the configuration will be read from the SW user configuration. The DIP switches are different in each of the RAD devices. In the Tiny Router (starting from the LSB) the following switches exist: Bit 0: WAN Loop Bit 1: LAN Full Duplex (When LAN AUI connector, it is SQE) Bit 2: PPP (When WAN 4 Wire connector, it is LONG) Bit 3: IP Learn
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

sysSaBuActivePort 1.3.6.1.4.1.164.3.3.1.1.6
This object shows through which port the traffic is flowing (the current Active Port) when the Backup mechanism exists. When No Backup exists in the device, the value should be: notApplicable(1).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), e1T1orSerial(2), eth(3), primary(4), secondary(5), third(6), fourth(7)  

sysChas 1.3.6.1.4.1.164.3.3.1.2.1
OBJECT IDENTIFIER    

chassTotalNoOfSlt 1.3.6.1.4.1.164.3.3.1.2.1.1
This object indicates the number of physical slots in the Hub chassis.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

chassTotalNoOfIoSlt 1.3.6.1.4.1.164.3.3.1.2.1.2
This object indicates the total number of physical IO slots in the chassis, (not all slots must be occupied and active).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

chassTotalNoOfPsSlt 1.3.6.1.4.1.164.3.3.1.2.1.3
This object indicates the number of physical Power Supply slots in the chassis.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

chassTotalNoOfClSlt 1.3.6.1.4.1.164.3.3.1.2.1.4
This object indicates the number of physical Common Logic slots in the chassis.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

chassTotalNoOfMlSlt 1.3.6.1.4.1.164.3.3.1.2.1.5
This object indicates the number of physical Main Link slots in the chassis (Kmux).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sysDcl 1.3.6.1.4.1.164.3.3.1.2.2
OBJECT IDENTIFIER    

sysDclTable 1.3.6.1.4.1.164.3.3.1.2.2.1
All the entries of this table are identical (have the same value) for all the configurations (1..255) except the TmpCnfg. The write operation into the Table Objects is valid only for the TmpCnfg entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SysDclEntry

sysDclEntry 1.3.6.1.4.1.164.3.3.1.2.2.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SysDclEntry  

sysDclCnfgIdx 1.3.6.1.4.1.164.3.3.1.2.2.1.1.1
This object indicates the Idx of the Cnfg(1..255) being accessed ; Idx of 255 relates to the TmpCnfg. This object is identical for all the configurations (1..255). Only the TmpCnf(255) might have a different value. For devices that work on line with NMS (no Temp configuration in NMS), Get and Set will be performed with index value of sysDclCnfgIdx = 1.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

sysDclRedundancy 1.3.6.1.4.1.164.3.3.1.2.2.1.1.2
DCL redundancy desired state.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

sysDclActiveCl 1.3.6.1.4.1.164.3.3.1.2.2.1.1.3
Active desired DCL. When 'auto' is selected, the system automatically selects the active DCL.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER auto(1), dclA(2), dclB(3)  

sysDclFlipDelay 1.3.6.1.4.1.164.3.3.1.2.2.1.1.4
If one DCL flip occurred and a second one should be performed, the time from the previous flip is checked. If the time is shorter than the delay specified here, the system should delay the flip operation until time reaches the specified delay. For DXC the values are 1 minute to 4 minutes (1..4). For Optimux-155-1 and Optimux-155-3 the values are: 0...60 Sec. 0 means No Delay.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

sysDclFlipUponStnClk 1.3.6.1.4.1.164.3.3.1.2.2.1.1.5
This object allows user to decide (yes/no) if Agent should Flip from one DCL card to another, when there is Station Clock Fail in the Online DCL card.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

sysDclChFailThreshold 1.3.6.1.4.1.164.3.3.1.2.2.1.1.6
This object indicates the number of failed channels that will trigger the redundancy procedure.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

sysDclChPriority 1.3.6.1.4.1.164.3.3.1.2.2.1.1.7
This object indicates the Priority for all the channels in the Main Access (Common Logic) card. Each channel is represented by 1 bit. The order of the bits in each byte is from Right to Left (LSB Bit to MSB) starting from BIT 0: 7 6 5 4 3 2 1 0 Channel no. 1 is represented by bit 0. Channel no. 2 is represented by bit 1. Channel no. n is represented by bit n-1. The value of the bit shows the priority. For bit value = 1, Priority = High. For bit value = 0, Priority = Low.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

sysDclConfigDownloadSrc 1.3.6.1.4.1.164.3.3.1.2.2.1.1.8
In case of mismatch between the 2 CL card's configuration, the user can decide which card has the suitable configuration. The selected configuration will be downloaded from card A to card B if the value is dclA(2) or from card B to card A if the value is dclB(3). off(1) is used by part of the devices. In this case, after operation ends - value should be automatically set to off(1), which is the default state.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(1), dclA(2), dclB(3)  

sysDclSwDownloadSrc 1.3.6.1.4.1.164.3.3.1.2.2.1.1.9
In case of mismatch between the 2 CL card's software, the user can decide which card has the suitable SW. The selected SW will be downloaded from card A to card B if the value is dclA(2) or from card B to card A if the value is dclB(3). off(1) is used by part of the devices. In this case, after operation ends - value should be automatically set to off(1), which is the default state.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(1), dclA(2), dclB(3)  

sysDclRedundancyStatus 1.3.6.1.4.1.164.3.3.1.2.2.1.1.10
Bit map representing current Redundancy Status. bit 0 - Indicates mismatch between the 2 CL cards' Configuration bit 1 - Indicates mismatch between the 2 CL cards' Software. bit 2 - Indicates CL card A Absence. bit 3 - Indicates CL card B Absence. bit 4 - Indicates Loss of Communication between the 2 CL cards. bit 5 - Indicates mismatch between the 2 CL cards' Hardware. bit 6 - Indicates Configuraton update is in process. bit 7 - Indicates Software update is in process.
Status: current Access: read-only
OBJECT-TYPE    
  BITS cnfgMismatch(0), swMismatch(1), cardAAbsent(2), cardBAbsent(3), lossOfCommunication(4), hwMismatch(5), cnfgUpdate(6), swUpdate(7)  

sysDclOnline 1.3.6.1.4.1.164.3.3.1.2.2.2
The active Dcl card of the agent.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER dclA(1), dclB(2)  

sysDclCopyDbTable 1.3.6.1.4.1.164.3.3.1.2.2.3
This table enables to copy a cofiguration from the Offline Dcl to the Online Dcl.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SysDclCopyDbEntry

sysDclCopyDbEntry 1.3.6.1.4.1.164.3.3.1.2.2.3.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SysDclCopyDbEntry  

sysDclCopyDbIdx 1.3.6.1.4.1.164.3.3.1.2.2.3.1.1
This object indicates the Idx of the Cnfg(1..255) being accessed.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

sysDclCopyDbCmd 1.3.6.1.4.1.164.3.3.1.2.2.3.1.2
When this command is sent to the agent, on(3), the Database specified (Db Idx), will be copied from the Offline Dcl to the Online Dcl. Afterwards the value of this object will automatically change to off(2).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

sysDclFlipCmd 1.3.6.1.4.1.164.3.3.1.2.2.4
When the 'flip(3)' command is received by Agent, it will flip (switch) between Offline Dcl and Online Dcl cards. Afterwards the value of this object will automatically change to off(2).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), flip(3)  

sysSDateFormat 1.3.6.1.4.1.164.3.3.1.3.1
This object indicates the date and time format used for the sysSDateAndTimeCmd and for the alarm buffer report.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ddMMYYYY(1), mmDDYYYY(2), yyyyMMDD(4)  

sysSDateCmd 1.3.6.1.4.1.164.3.3.1.3.2
This object indicates the current date as it is known by the agent using its own real-time clock. The format would be as specified by the sysSDateFormat. This parameter can be set for time synchronization between the NMS and the Agent. * For KM-2100 V1 and FCD-T1/E1 - the string should contain '/' signs between day, month and year. Example: 12/08/1998. * For DXC and rest of the products - the string should contain '-' signs between day, month and year. Example: 12-08-1998. The day value will be in the range: 1..31. The month value will be in the range: 1..12. The year value will be in the range: 1996..2050 for products supporting the '-' format.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..255)  

sysSTimeCmd 1.3.6.1.4.1.164.3.3.1.3.3
This object indicates the current time as it is known by the agent using its own real-time clock. This parameter can be set for time synchronization between the NMS and the Agent. The string should contain ':' signs between hour, minute and second. Example: 11:05:58.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..255)  

sysSActiveCnfg 1.3.6.1.4.1.164.3.3.1.3.4
This object specifies the configuration number, that is currently active and running.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sysSEditCnfg 1.3.6.1.4.1.164.3.3.1.3.5
This object indicates the unique configuration number that is currently loaded into the tmp working space for manipulation and update operations. Value of 255 means no config. is under editing process.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sysSEditBy 1.3.6.1.4.1.164.3.3.1.3.6
This entry indicates which MMI application is working on the edited config. The editing phase starts at the first modify operation and ends after a load operation.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(1), snmp(2), terCon1(3), terCon2(4), terInbandCon1(5), terInbandCon2(6), lcd(7)  

sysSClkSrc 1.3.6.1.4.1.164.3.3.1.3.7
This entry indicates the source of the system clock.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER master(1), fallback(2), internal(3), ml(4)  

sysSAlrStatus 1.3.6.1.4.1.164.3.3.1.3.8
Indicates the current alarm state only for system level. This object will be : - critical(7): when there is at least one active (ON) critical alarm . - major (3): when there is no active critical alarm, but there is at least one active (ON) major alarm . - minor (4): when there is no active major or critical alarm, but there is at least one active minor alarm. - warning (6): when there is no active major, critical or minor alarm, but there is at least one active warning alarm. - event (5): when there is no active alarm of another type, but there is at least one active event alarm. - off(2): when there is no active (ON) alarm (since last clear operation).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(2), major(3), minor(4), event(5), warning(6), critical(7)  

sysSAlrStatusAll 1.3.6.1.4.1.164.3.3.1.3.9
Indicates the current alarm state including all levels: system, card, port. - critical(7): when there is at least one active (ON) critical alarm . - major (3): when there is no active critical alarm, but there is at least one active (ON) major alarm . - minor (4): when there is no active major or critical alarm, but there is at least one active minor alarm. - warning (6): when there is no active major, critical or minor alarm, but there is at least one active warning alarm. - event (5): when there is no active alarm of another type, but there is at least one active event alarm. - off(2): when there is no active (ON) alarm (since last clear operation).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(2), major(3), minor(4), event(5), warning(6), critical(7)  

sysSTestStatus 1.3.6.1.4.1.164.3.3.1.3.10
Indicates the current test status (for all levels: system, card, port). This attribute will be set to: - on(3): when there is at least one test in progress on the system/card/port otherwise the value will be off(2).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(2), on(3)  

sysSSanityCheckStatus 1.3.6.1.4.1.164.3.3.1.3.11
Upon completion of the Sanity Check process on the TmpCnfg this object will be set to: - fail(2): when there is at least one error (which is not just a warning) encountered otherwise, - warning(3): when there are only warnings otherwise, - ok(4). The value should be unknown(1), if the TmpCnfg was changed after the last Sanity check.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), fail(2), warning(3), ok(4)  

sysSNoOfSanityCheckErr 1.3.6.1.4.1.164.3.3.1.3.12
This object indicates the number of errors/warnings discovered by the last Sanity Check process.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sysSErrListTable 1.3.6.1.4.1.164.3.3.1.3.13
A table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SysSErrListEntry

sysSErrListEntry 1.3.6.1.4.1.164.3.3.1.3.13.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SysSErrListEntry  

sysSErrType 1.3.6.1.4.1.164.3.3.1.3.13.1.1
The errors are recorded in the agent, in two separate lists, according to their type: error or warning.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER error(1), warning(2)  

sysSErrIdx 1.3.6.1.4.1.164.3.3.1.3.13.1.2
Unique index number to identify an entry in the error or warning list . The maximum value cannot exceed the value of 'sysSNoOfSanityCheckErr' (actually, the sum of the Errors list max. index and the Warning list max. index should equal the value of'sysSNoOfSanityCheckErr').
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sysSErrDescription 1.3.6.1.4.1.164.3.3.1.3.13.1.3
This object is a full text description of the sanity check error including error code, IO slot and port numbers related to the code .
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

sysSMaxNoOfCnfg 1.3.6.1.4.1.164.3.3.1.3.14
Maximum number of configurations that can be defined and stored in the DACS agent. If the DACS agent has a large capacity, the maximum will be limited to 254.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sysSSelfTestResult 1.3.6.1.4.1.164.3.3.1.3.15
The test is performed by the active Common Logic card. The result will be a sum of 2**n according to the following bit convention: For DXC: bit 0 Database 1 Checksum Error (LSB) bit 1 Database 2 Checksum Error bit 2 I/O Expander Error bit 3 Counter Error bit 4 Matrix DPR Error bit 5 PS-A 5 Volt Error bit 6 PS-A 12 Volt Error bit 7 PS-B 5 Volt Error bit 8 PS-B 12 Volt Error bit 9 EPROM Failure For FCD: bit 0 I/O Expander Error (LSB) bit 1 Counter Error bit 2 EPROM Failure bit 3 Illegal Sys Config bit 4 SFIFO bit 5 EPIC Failure (ISDN) bit 6 XL Flash Fail -- for MSDSL interface bit 7 XL MITEL Fail -- for MSDSL interface bit 8 XL Framer Fail -- for MSDSL interface bit 9 XL DSP Fail -- for MSDSL interface For LRS52 - refer to product's spec When a bit is ('1'), the error exists. When NO ERROR is encountered, this object's value will be 0.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sysSRelayState 1.3.6.1.4.1.164.3.3.1.3.16
Indicates the current state of the alarm relay. notApplicable - for agents that do not support this object.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), off(2), on(3)  

sysSInvertedAlr 1.3.6.1.4.1.164.3.3.1.3.17
Indicates if there is any Inverted alarm at any level of the system (sys, card, port). notApplicable - for agents that do not support this object.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

sysSRdnFlipTable 1.3.6.1.4.1.164.3.3.1.3.18
This table includes all the Flip events due to I/O Redundancy since last Clear command of this table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SysSRdnFlipEntry

sysSRdnFlipEntry 1.3.6.1.4.1.164.3.3.1.3.18.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SysSRdnFlipEntry  

sysSRdnFlipIdx 1.3.6.1.4.1.164.3.3.1.3.18.1.1
Unique index number to identify an entry in the Redundancy Flip list.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sysSRdnFlipSlot 1.3.6.1.4.1.164.3.3.1.3.18.1.2
The slot number from which Flip was performed.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), notApplicable(255)  

sysSRdnFlipPort 1.3.6.1.4.1.164.3.3.1.3.18.1.3
The port number from which Flip was performed. For DXC: For external ports the convention used will be: - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . For internal ports the convention used will be: - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 . For MP: For external ports, the value will be as that of the port in the card. Example: external-3 -> 3 external-4 -> 4 For internal ports, the value will be 100 + the port in the card. Example: internal-1 -> 101 internal-4 -> 104 100=notApplicable (when Redundancy is at card level).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sysSRdnFlipCause 1.3.6.1.4.1.164.3.3.1.3.18.1.4
The last cause that caused the Flip from the Slot (Port) of sysSRdnSlot, sysSRdnPort.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

sysSRdnFlipDate 1.3.6.1.4.1.164.3.3.1.3.18.1.5
Flip event Date. The format will be the one selected by user for sysSDateFormat.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

sysSRdnFlipTime 1.3.6.1.4.1.164.3.3.1.3.18.1.6
Flip event Time. The format will be hh:mm:ss.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

sysSRdnFlipTableClearCmd 1.3.6.1.4.1.164.3.3.1.3.19
This command, when Set to 'on', clears the Redundancy Flip table (sysSRdnFlipTable). After clear is performed, the agent will turn the value to 'off' automatically.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

sysSRdnFlipCmd 1.3.6.1.4.1.164.3.3.1.3.20
This object enables the user to send a command to the Agent, to Flip from a current Online IO card to its Redundant card. The value sent will be an Object Identifier of an entry in the sysCRdnTable. This entry defines the Redundant couple of Slots on which the Flip is applied. Setting this object, will cause the Agent to Flip from current Online card to its Redundant card. This manual flip command is applicable only for entries having Redundancy Mode=Y Cable. For Vmux: This command will cause flipping from Secondary or Third Link to the Primary Link. If the active link is the primary link, the agent will flip to the secondary link. The value sent will be the Object Identifier of the following Table: agnCBuMlTable. Agent will send the value 0 for Get.
Status: current Access: read-write
OBJECT-TYPE    
  OBJECT IDENTIFIER  

sysSBusTable 1.3.6.1.4.1.164.3.3.1.3.21
This table includes data and status about the internal DXC BUS.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SysSBusEntry

sysSBusEntry 1.3.6.1.4.1.164.3.3.1.3.21.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SysSBusEntry  

sysSBusPortIdx 1.3.6.1.4.1.164.3.3.1.3.21.1.1
The DXC BUS port number: - first two digits will be: (IO slot number+10) - last one/two digits will be the Bus port number, in odd numbers: port1 = 1 port2 = 3 Example: port2 of IO slot 11 will be: 213.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sysSBusStatus 1.3.6.1.4.1.164.3.3.1.3.21.1.2
The Status of sysSBusPortIdx. free - not used physical - captured by the port of the card physically installed virtual - captured virtually by another port. Example: DIM port (by Destination) or by Transparent T3/E3 port.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER free(1), physical(2), virtual(3)  

sysSBusCapturePort 1.3.6.1.4.1.164.3.3.1.3.21.1.3
The Port that Captured the sysSBusPortIdx. - if sysSBusStatus=free, the value will be 'none'=0 - else, if sysSBusStatus=fixed, the value will be: sysSBusPortIdx - else, the value will be according to the port index that captured this Bus Port (according to DXC port index convention): - xx1, xx3, xx11, xx13, xx31, xx33, xx2..xx56(even numbers) - xx = (IO slot number+10)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sysSBusUtilization 1.3.6.1.4.1.164.3.3.1.3.21.1.4
Utilization of sysSBusPortIdx resources, in percent [%].
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sysSAlrAttrIndication 1.3.6.1.4.1.164.3.3.1.3.23
This object indicates the status of the Alarm Attributes for the whole device. It is a sum of 2**(Bit-1). A Bit will be '1', when any alarm in the device is Filtered/Masked/Inverted (respectively). The Bit assignment is: Bit 1: Filter (LSB) Bit 2: Mask Bit 3: Invert (MSB). Examples: - Alarms are filtered and masked but not inverted: value=3 - Alarm is Inverted (not filtered or masked): value=4 - Alarm is masked (not inverted or filtered): value=2
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sysSAlrTable 1.3.6.1.4.1.164.3.3.1.4.1
List of system level current existing alarms .
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SysSAlrEntry

sysSAlrEntry 1.3.6.1.4.1.164.3.3.1.4.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SysSAlrEntry  

sysSAlrIdx 1.3.6.1.4.1.164.3.3.1.4.1.1.1
An index number of the current system alarms.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sysSAlrCode 1.3.6.1.4.1.164.3.3.1.4.1.1.2
This object indicates a code related to a specific alarm description. The list of codes and their related descriptions will be sent to NMS request (for display purpose) by alrGenTable.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sysSAlrState 1.3.6.1.4.1.164.3.3.1.4.1.1.3
This object indicates the alarm Severity.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER event(3), minor(4), major(5), warning(6), critical(7)  

sysSAlarmMask 1.3.6.1.4.1.164.3.3.1.4.1.1.4
Alarm Mask is : on/off.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(2), on(3)  

sysSAlarmInvert 1.3.6.1.4.1.164.3.3.1.4.1.1.5
Alarm Invert is : on/off.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(2), on(3)  

sysSAlarmOnOff 1.3.6.1.4.1.164.3.3.1.4.1.1.6
Alarm state is : on/off.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(2), on(3)  

sysSAlarmCounter 1.3.6.1.4.1.164.3.3.1.4.1.1.7
A counter - how many times the alarm occured (ON) since last clear operation or since last Reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sysSAlrClearCmd 1.3.6.1.4.1.164.3.3.1.4.2
Setting this attribute to ON, will enforce a clear operation on the system level alarms . Upon completion, the value will automatically change to off(2).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

sysSAlrClearAllCmd 1.3.6.1.4.1.164.3.3.1.4.3
Setting this attribute to ON, will enforce a clear operation on all levels alarms . Upon completion, the value will automatically change to off(2).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

sysSAlrMaskAll 1.3.6.1.4.1.164.3.3.1.4.4
on(3) - will cause masking of all the system level alarms. These alarms will not be sent to NMS and will not be taken into account for Alarms Status. off(2) - will unmask all system level alarms except those masked via the sysSAlrMask.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

sysSAlrMask 1.3.6.1.4.1.164.3.3.1.4.5
This object is a mask that indicates which system level alarms are masked. The masked alarms (their bit is set to '1') are neither sent to the manager, nor taken into account for alarm status and LEDs. Bit no. = Alarm code The bits that do not belong to the system level will be 0. This object is applicable only when sysSAlrMaskAll=off (otherwise all system alarms are masked). Example: When Alarms having the codes 6 and 11 are masked, the value of this object will be 840 (hex).
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8)  

sysSAlrDataUpdateCmd 1.3.6.1.4.1.164.3.3.1.4.6
on(3) - will cause Update of the Alarms Severity, Attributes and Report tables. off(2) - Upon completion, the value will automatically change to off(2).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

sysBufferAlrTable 1.3.6.1.4.1.164.3.3.1.5.1
List of current existing alarms (of all levels).
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SysBufferAlrEntry

sysBufferAlrEntry 1.3.6.1.4.1.164.3.3.1.5.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SysBufferAlrEntry  

sysBufferAlrIdx 1.3.6.1.4.1.164.3.3.1.5.1.1.1
An index number of the current alarms.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sysBufferAlrCode 1.3.6.1.4.1.164.3.3.1.5.1.1.2
This object indicates a code related to a specific alarm description. The list of codes and thir related descriptions will be known by the NMS (for display purpose) and will appear in the unit's user manual.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sysBufferAlrState 1.3.6.1.4.1.164.3.3.1.5.1.1.3
This object indicates the alarm type. minor/major/warning/critical - indicates appearance of the problem and the type. event - indicates occurence of an event. off - indicates disappearance of an alarm.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(2), event(3), minor(4), major(5), warning(6), critical(7)  

sysBufferAlrSlot 1.3.6.1.4.1.164.3.3.1.5.1.1.4
The slot number this alarm refers to. When the alarm refers to a system function OR the DACS agent is a stand-alone unit, the value will be 'notApplicable(255)'. local/remote - for OP-4 device.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER psA(1), psB(2), clA(3), clB(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), local(20), psC(21), kmxPsA(101), kmxPsB(102), kmxMlA(103), kmxMlB(104), kmxCl(105), kmxOpt(106), kmxIO1(107), kmxIO2(108), kmxIO3(109), kmxIO4(110), kmxIO5(111), kmxIO6(112), kmxIO7(113), kmxIO8(114), kmxIO9(115), kmxIO10(116), kmxIO11(117), kmxIO12(118), remote(120), notApplicable(255)  

sysBufferAlrPort 1.3.6.1.4.1.164.3.3.1.5.1.1.5
The port number this alarm refers to. If the port number is irrelevant to this alarm (if it is a system/card level alarm) the value will be 9999.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sysBufferAlrDate 1.3.6.1.4.1.164.3.3.1.5.1.1.6
The date when the alarm occured. The format will be according to sysSDateFormat.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

sysBufferAlrTime 1.3.6.1.4.1.164.3.3.1.5.1.1.7
The time when the alarm occured.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

sysBufferAlrUpTime 1.3.6.1.4.1.164.3.3.1.5.1.1.8
The time when the alarm occured. This parameter holds the sysUpTime value when the alarm occured.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

sysBufferAlrInfo 1.3.6.1.4.1.164.3.3.1.5.1.1.9
This parameter includes information about the alarm (additional to the Description).
Status: current Access: read-only
OBJECT-TYPE    
  SnmpAdminString  

sysBufferAlrClearCmd 1.3.6.1.4.1.164.3.3.1.5.2
Setting this attribute to ON, will enforce a clear operation on the Alarms Buffer. Upon completion, the value will automatically change to off(2).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

sysCClkSrcTable 1.3.6.1.4.1.164.3.3.1.6.1
All the entries of this table are identical (have the same value) for all the configurations (1..255) except the TmpCnfg. For devices with more than one configuration: The write operation into the Table Objects is valid only for the TmpCnfg entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SysCClkSrcEntry

sysCClkSrcEntry 1.3.6.1.4.1.164.3.3.1.6.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SysCClkSrcEntry  

sysCClkCnfgIdx 1.3.6.1.4.1.164.3.3.1.6.1.1.1
This attribute indicates the Idx of the Cnfg being accessed ; Idx of 255 relates to the TmpCnfg. It can be also a combination of the configuration number and the Card/Port/Other System index.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..2147483647  

sysCClkSrcIdx 1.3.6.1.4.1.164.3.3.1.6.1.1.2
An index in the table. There are only two entries in the table. master - refers Master clock parameters fallback - refers Fallback clock parameters
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER master(1), fallback(2)  

sysCClkSrcMode 1.3.6.1.4.1.164.3.3.1.6.1.1.3
This entry indicates the source the nodal timing is locked to. none - is an invalid option for Master clock. internal - is an invalid option for Fallback clock . station - is an invalid option for a stand-alone unit. lbt - loop-back timing ntr - Network Time Reference adaptive - clock locking is achieved by altering the clock according to the data load system - irrelevant when sysCClkCnfgIdx refers to System Clock. sSubSystem - SONET/SDH Sub System. recovered - clock recovery. notApplicable - for ML source of Kmux or ML Timing combinations when Master/Fallback clock are not applicable.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), internal(2), rxClk(3), station(4), lbt(5), ntr(6), adaptive(7), stationB(8), automatic(9), system(10), sSubSystem(11), recovered(12), notApplicable(255)  

sysCClkSrcPrt 1.3.6.1.4.1.164.3.3.1.6.1.1.4
This entry is valid only when working in rxClk mode (for IPmux1000 this entry will be valid whe working in LBT mode). For ACE2002 in case of invalid entry the return value will be 0. For other products in case of invalid entry the return value will be 9999. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside, SP. * The SP ports will be numbered as follows: - SP port 1 : 1 - SP port 2 : 2 For external ports the convention used will be (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . For internal ports the convention used will be (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 . For Kmux, the port will be according to : Slot*100+Ch. For ACE2002, LA140 and IPmux1000 (GMUX), the port will be ifIndex.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

sysCClkStationFreq 1.3.6.1.4.1.164.3.3.1.6.1.1.5
This entry indicates the frequency of the station clock when the source is 'station'. The value will be applicable only when the sysCClkSrcMode is 'station'.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), f1544Khz(2), f2048Khz(3)  

sysCClkRevertiveTimeout 1.3.6.1.4.1.164.3.3.1.6.1.1.6
The time in seconds in which the system will monitor the higher level clock source, before decision to revert to that clock. In case the time is zero, revertive mode will be disabled.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

sysCClkStationIf 1.3.6.1.4.1.164.3.3.1.6.1.1.7
This entry indicates the electrical interface connected to the station clock, when the source is 'station'. The value will be applicable only when the sysCClkSrcMode is 'station'.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), g703(2), rs422(3), g703E1Unbalanced(4), g703T1(5), rs422T1(6)  

sysCClkStationCableMode 1.3.6.1.4.1.164.3.3.1.6.1.1.8
This parameter indicates whether both Station clocks get their clock from the same source (Y Cable)or each one get its clock independently. The value will be applicable only when the sysCClkSrcMode is 'station'.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), normal(2), yCable(3)  

sysCClkStationOutState 1.3.6.1.4.1.164.3.3.1.6.1.1.9
This parameter indicates whether station clock can send its clock to another device. The value will be applicable only when the sysCClkSrcMode is 'station'.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

sysCClkSsmBased 1.3.6.1.4.1.164.3.3.1.6.1.1.10
This parameter indicates whether clock source will be selected based on receive clock quality, indicated in S1 byte inside SONET/SDH overhead, (encoded as SSM - Synchronization Status Messaging). It is relevant only for sysCClkSrcIdx=master. When the value is Yes, sysCClkSrcMode must be notApplicable.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

sysCClkSSubsystemSlot 1.3.6.1.4.1.164.3.3.1.6.1.1.11
This entry indicates the Slot from which the S Subsytem Source will be taken. The value will be applicable only when the sysCClkSrcMode is 'sSubsystem'.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), clA(3), clB(4)  

sysCClkRecoveredID 1.3.6.1.4.1.164.3.3.1.6.1.1.12
This entry indicates the Recovered Clock ID. The value will be applicable only when sysCClkSrcMode is 'recovered'.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

sysCnfgTable 1.3.6.1.4.1.164.3.3.1.6.2
All the entries of this table are identical (have the same value) for all the configurations (1..255) except the TmpCnfg. The write operation into the Table Objects is valid only for the TmpCnfg entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SysCnfgEntry

sysCnfgEntry 1.3.6.1.4.1.164.3.3.1.6.2.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SysCnfgEntry  

sysCnfgIdx 1.3.6.1.4.1.164.3.3.1.6.2.1.1
This attribute indicates the Idx of the Cnfg(1..255) being accessed ; Idx of 255 relates to the TmpCnfg. For Gmux2000 the range limitation (1..255) was discarded since the Idx is computed as: x 1000 + 255.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sysCMatrixMode 1.3.6.1.4.1.164.3.3.1.6.2.1.2
Indicates the TS Matrix Mode: bidirectional - TS Assignment Matrix is symmetric. unidirectional - TS Assignment Matrix can be asymmetric. notApplicable - for agents that do not support this feature.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), bidirectional(2), unidirectional(3)  

sysCIsdnFormat 1.3.6.1.4.1.164.3.3.1.6.2.1.3
ISDN format. This parameter controls the operation mode of the ISDN ports. te - ISDN timing is derived from the signal received from the equipment it is connected to. nt - timing of the transmit path is locked to the nodal timing source. notApplicable - for agents that do not support this feature.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), te(2), nt(3)  

sysCRoutingOnEth 1.3.6.1.4.1.164.3.3.1.6.2.1.4
Mng Routing Protocol on the online CL Ethernet port, or on device Ethernet port dedicated for mangement.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), none(2), proprietary(3), rip2(4), rip1(5), rip1and2(6)  

sysCAutoConfigEnable 1.3.6.1.4.1.164.3.3.1.6.2.1.5
This object enables user to enable/disable activating the Auto Configuration. When Auto Configuration is activated, the device learns its configuration Automatically from the Net it is connected to.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

sysCIntTsAllocMode 1.3.6.1.4.1.164.3.3.1.6.2.1.6
This object enables user to select the mode of Internal TS Allocation. static - user has to select for each Dynamic card port, the Maximum TSs expected to be connected (including future growth). This number will be allocated to the ports, so that if number of connected TSs will grow within the limits of this Maximum TS limit, no disruption of data flow will occur for other ports. dynamic- TS allocation is done dynamically according to the connected TSs. No future reservations are done. This mode may cause data disruption on other ports/slots if user will want to change the number of connected TSs for a Dynamic card port. staticOneToOne - user has to select for each Dynamic card port, the Maximum TSs expected to be connected (including future growth). In addition, the TSs themselves cannot be higher than this defined Maximum (e.g if Maximum TSs=5 user cannot selects TSs higher than 5). This mode ensures that if number of TSs grow within the limits of this Maximum TS limit, no disruption of data flow will occur for other ports AND for the selected port itself. Default=static(2).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), static(2), dynamic(3), staticOneToOne(4)  

sysCBuPrimaryPort 1.3.6.1.4.1.164.3.3.1.6.2.1.7
This object enables the user to configure a Backup mechanism. If a backup mechanism exists, it is possible to configure the primary port. The traffic will flow via the primary port when the port functionality is OK. In Vmux-2100 device the backup mechanism is relevant for the Main Board only. The primary port can be the E1/T1/Serial port or the ETH port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noBackup(2), e1T1orSerial(3), eth(4)  

sysCEnableLanOverTdm 1.3.6.1.4.1.164.3.3.1.6.2.1.8
This object enables/disables transferring traffic from the LAN port to the TDM port. It is possible to enable only part of the traffic on the TDM port for security reasons or in order to minimize the bandwidth .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enableAll(2), enableVoiceOnly(3), enableVoiceAndMng(4)  

sysCSs7FisuSuppression 1.3.6.1.4.1.164.3.3.1.6.2.1.9
SS7 Suppresion is used for SS7 Spoofing. The SS7 spoofing terminates the keep alive messages from the local VMUX without sending them over the network, thus improving the bandwidth utilization. FISU means Fill in Service Unit - Keep alive that is sent when no one is talking on the line. This object enables the configuration of the SS7 Keep Alive packet % that will be discarded. Legal Values: 0 - No Suppression, 10%, 20%, 30% .. 90% Example: For a value of 10, 1 keep alive packet will be discarded out of 10 keep alive packets that were supposed to be sent over the network.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

sysCBuRecMode 1.3.6.1.4.1.164.3.3.1.6.2.1.10
Recovery Mode. This object determines if after recovery of the Primary Link (used in Vmux) it will become on-line again or not: auto - automatic. In this case, the failed Link will become on-line again after recovery, automatically. manual - In this case, the failed Link will not become on-line again after recovery but user can manually flip to this Link.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER auto(2), manual(3)  

sysCRdnTable 1.3.6.1.4.1.164.3.3.1.6.3
Configuration of all Redundant I/O cards and ports. The write operation into the table objects is valid only for the TmpCnfg. A Slot/Port that have no Redundancy, will not exist in this table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SysCRdnEntry

sysCRdnEntry 1.3.6.1.4.1.164.3.3.1.6.3.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SysCRdnEntry  

sysCRdnCnfgIdx 1.3.6.1.4.1.164.3.3.1.6.3.1.1
This object indicates the Idx of the Cnfg(1..255) being accessed ; Idx of 255 relates to the TmpCnfg.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sysCRdnPrimeSlot 1.3.6.1.4.1.164.3.3.1.6.3.1.2
The slot number of the Primary card of Redundancy. The Primary card should be the card that user wishes to be the online card (usually the more important one). For some Redundancy modes the importance of the redundant cards/ports is the same.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), notApplicable(255)  

sysCRdnPrimePort 1.3.6.1.4.1.164.3.3.1.6.3.1.3
The port number. For DXC: For external ports the convention used will be: - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . For internal ports the convention used will be: - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 . For MP: For external ports, the value will be as that of the port in the card. Example: external-3 -> 3 external-4 -> 4 For internal ports, the value will be 100 + the port in the card. Example: internal-1 -> 101 internal-4 -> 104 For IP Bundles, the value will be the Bundle ifIndex. For an IP Bundle that is in an External Device (not in this MP), the value will be: 70,000 + ifIndex of Secondary Bundle. For other products - refer to product specification. 100=notApplicable (when Redundancy is at card level).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sysCRdnSecSlot 1.3.6.1.4.1.164.3.3.1.6.3.1.4
The slot number of the Secondary card of Redundancy matching the Primary slot.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), notApplicable(255)  

sysCRdnSecPort 1.3.6.1.4.1.164.3.3.1.6.3.1.5
The port number. For DXC: For external ports the convention used will be: - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . For internal ports the convention used will be: - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 . For MP: For external ports, the value will be as that of the port in the card. Example: external-3 -> 3 external-4 -> 4 For internal ports, the value will be 100 + the port in the card. Example: internal-1 -> 101 internal-4 -> 104 For IP Bundles, the value will be the Bundle ifIndex. For an IP Bundle that is in an External Device (not in this MP), the value will be: 0. For other products - refer to product specification. 100=notApplicable (when Redundancy is at card level).
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

sysCRdnMode 1.3.6.1.4.1.164.3.3.1.6.3.1.6
Redundancy Mode. DXC supports: yCable(3), singleSlotProtection(6) and dualCableParallelTx(4) MP supports: yCable(3), dualCableParallelTx(4), onePlusOne(7) and oneToOne(8). (dualCableAIS and backup were planned for MP but were not implemented). backup - will be used when a port is backup of more than one port. IPmux: onePlusOne(7) and oneToOne(8) are used for Bundle redundancy.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER dualCableAIS(2), yCable(3), dualCableParallelTx(4), backup(5), singleSlotProtection(6), onePlusOne(7), oneToOne(8), linkAggregation(9), manual(10)  

sysCRdnRecMode 1.3.6.1.4.1.164.3.3.1.6.3.1.7
Recovery Mode. This object determines if after recovery of the failed Primary card/port it will become on-line again or not: auto - automatic . In this case, the failed card/port will become on-line again after recovery, automatically. manual - In this case, the failed card/port will not become on-line again after recovery. But, user can manually flip to this card/port. nonRevertive - same as manual, but here user CANNOT manually flip to this card/port. It will become on-line again, only if the Secondary/Backup card/port will fail.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER auto(2), manual(3), nonRevertive(4)  

sysCRdnRecTime 1.3.6.1.4.1.164.3.3.1.6.3.1.8
Redundancy Recovery Time (sec). After switching to the current online card, the next switch can be performed only after a minimum time, indicated by this object. Valid Values: 0..300, 65535. 65535=NA. This object is applicable only when sysCRdnRecMode=auto.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

sysCRdnHwSwFlip 1.3.6.1.4.1.164.3.3.1.6.3.1.9
HW or SW decision for Redundancy Flip. This object is applicable only for sysCRdnMode=singleSlotProtection. HW - decision is by I/O card SW - decision is by CL SW.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER notApplicable(1), hw(2), sw(3)  

sysCRdnRowStatus 1.3.6.1.4.1.164.3.3.1.6.3.1.10
This parameter allows NMS to create/delete entries of this table. The possible supported RowStatus values are active (1) and destroy (6). For Vmux-2100 the supported values are: active (1), createAndGo (4) and destroy (6).
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

sysCRdnOnline 1.3.6.1.4.1.164.3.3.1.6.3.1.11
Status - who is the Online (current) Redundancy Slot/Port. This object shows only the Online Slot/Port regarding the Redundancy. mdlSActivity or prtGenActiveStatus of the same Slot/Port may be Offline.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), primary(2), secondary(3)  

sysCRdnSwitchingMode 1.3.6.1.4.1.164.3.3.1.6.3.1.12
This object defines which Self Healing Ring (SHR) SDH ring is used: Uni Directional or BiDirectional. The type of the ring is defined according to the direction of traffic flow under normal working conditions. In Bi Directional ring, the duplex traffic is on the same path and transverses the same set of nodes for both directions of transmission. In Uni Directional ring, the duplex traffic travels over opposite path (per direction) and all the node of the ring are involved. For Uni Directional SHR Protection Switching (Single Ended Switching) is controlled by one node of the SDH ring, and does not require a protocol. For Bi Directional SHR Protection Switching (Dual Ended switching) is controlled by some nodes of the ring and requires a protocol
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER notApplicable(1), biDirectional(2), uniDirectional(3), linkAggregation(4)  

sysCRdnFlipUponEvent 1.3.6.1.4.1.164.3.3.1.6.3.1.13
This object allows user to define if Flip to the other port will be performed (or not), for certain possible events. Each event is represented by a bit. The value of the object is a sum of 2**n, according to the bits having '1' value. '1' - means that Flip should occur due to this event. Bit 0 (LSB) = SD (Signal Degraded). For IPmux: Bit 0 (LSB) = TDM Line LOS/LOF. Bit 1 = Sequence Number. Bit 2 = Jitter Buffer errors.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

sysCRdnLosOrLofTime 1.3.6.1.4.1.164.3.3.1.6.3.1.14
This parameter determines how much time to wait before switching, after LOF or LOS are detected on the TDM Line. For Ipmux time is counted in msec.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

sysCRdnEventsTimeWindow 1.3.6.1.4.1.164.3.3.1.6.3.1.15
This parameter determines the time window in which to count events to trigger protection switching. For Ipmux time is counted in seconds.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

sysCRdnSequenceNumberThreshold 1.3.6.1.4.1.164.3.3.1.6.3.1.16
This parameter determines the number of Sequence Number errors that should occur in the time window in order to cause switching.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

sysCRdnBufferErrorsThreshold 1.3.6.1.4.1.164.3.3.1.6.3.1.17
This parameter determines the number of Buffer undeflow/ overflow events occured in the time window that cause switching.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

sysCRdnBuffUnderrunTime 1.3.6.1.4.1.164.3.3.1.6.3.1.18
This parameter determines how much time to wait before switching, after jitter buffer underrun. Switching occurs if no frame arrives within that time. For Ipmux time is counted in msec.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

sysCRdnPrimePriority 1.3.6.1.4.1.164.3.3.1.6.3.1.19
The Primary port priority. In ETX2xx/2xxA: When selecting sysCRdnMode = manual (10), this parameter determines the forced active port: low - means that the secondary port is selected to be active high - means that the primary port is selected to be active.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER notApplicable(1), low(2), high(3)  

sysCRdnSecPriority 1.3.6.1.4.1.164.3.3.1.6.3.1.20
The Secondary port priority.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER notApplicable(1), low(2), high(3)  

sysCRdnWTR 1.3.6.1.4.1.164.3.3.1.6.3.1.21
Redundancy Wait to Restore (sec). Valid Values: 0..999, 65535. 65535=NA. When the value <> 65535, the value of sysCRdnRecTime must be 65535.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

sysCRdnName 1.3.6.1.4.1.164.3.3.1.6.3.1.22
A textual name for the redundancy group.
Status: current Access: read-create
OBJECT-TYPE    
  SnmpAdminString  

sysCRdnTxDownDurationUponFlip 1.3.6.1.4.1.164.3.3.1.6.3.1.23
This object defines the duration (in seconds) the active port transmission is shut down after flip occurs. The transmission is shut down and then opened again (after the duration defined by this object), in order to cause the other side to flip to the new active port. 0 = no shut-down. This object is applicable only when sysCRdnMode = oneToOne(8) and mainly when each of the links of our device is connected to a different device.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..30  

sysSRdnCmdTable 1.3.6.1.4.1.164.3.3.1.3.22
This table includes commands used for IO Redundancy.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SysSRdnCmdEntry

sysSRdnCmdEntry 1.3.6.1.4.1.164.3.3.1.3.22.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SysSRdnCmdEntry  

sysSRdnEnforcedChannel 1.3.6.1.4.1.164.3.3.1.3.22.1.1
This is a command to override all switching considerations and enforce use of primary/ secondary connection only. noEnforcement - cancels the state of override and goes back to usual switching considerations. Default = noEnforcement(2).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), noEnforcement(2), primary(3), secondary(4)  

sysSRdnLockFlip 1.3.6.1.4.1.164.3.3.1.3.22.1.2
This is a command to lock the Redundancy flip for this redundancy couple. Default = off(2).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), off(2), on(3)  

sysSRdnManualFlip 1.3.6.1.4.1.164.3.3.1.3.22.1.3
This is a command to move to manual Redundancy flip mode for this redundancy couple. Default = off(2).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), off(2), on(3)  

sysDbaseSanityCheckCmd 1.3.6.1.4.1.164.3.3.1.7.1
Setting this attribute to on(3) will initiate the process of Sanity check on the TmpCnfg. Upon completion, the value will automatically change to off(2).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

sysDbaseDownloadCnfgIdxCmd 1.3.6.1.4.1.164.3.3.1.7.2
This attribute specifies the Id of the target RealCnfg to which the TmpCnfg should be transferred. Upon set command, the DACS agent will initiate the Sanity-Check process. If successful, the actual transfer will be performed. If there will be errors, the user will have to perform the command again after errors correction. The operation is valid only on configuration numbers that do not exceed sysSMaxNoOfCnfg.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..255  

sysDbaseUploadCnfgIdxCmd 1.3.6.1.4.1.164.3.3.1.7.3
This attribute specifies the Id of the source Cnfg to be loaded into the TmpCnfg. Upon set operation the actual transfer will be initiated. The operation is valid only on configuration numbers that do not exceed sysSMaxNoOfCnfg.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..255  

sysDbaseFlipTable 1.3.6.1.4.1.164.3.3.1.7.4
Dbase Flip time and activation for every configuration.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SysDbaseFlipEntry

sysDbaseFlipEntry 1.3.6.1.4.1.164.3.3.1.7.4.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SysDbaseFlipEntry  

sysDbaseFlipIdx 1.3.6.1.4.1.164.3.3.1.7.4.1.1
This attribute indicates the Idx of the Cnfg being the target Configuration.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

sysDbaseFlipTime 1.3.6.1.4.1.164.3.3.1.7.4.1.2
This attribute indicates the time (HH:MM) when this data base will start being used by the Tmp config.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..255)  

sysDbaseFlipActivation 1.3.6.1.4.1.164.3.3.1.7.4.1.3
This attribute indicates if the Dbase flip will be activated at the time specified for this configuration (enable) or not (disable). No more than one flip should be enabled for the same time.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

mdlGen 1.3.6.1.4.1.164.3.3.2.1
OBJECT IDENTIFIER    

mdlCl 1.3.6.1.4.1.164.3.3.2.2
OBJECT IDENTIFIER    

mdlPs 1.3.6.1.4.1.164.3.3.2.3
OBJECT IDENTIFIER    

mdlSTable 1.3.6.1.4.1.164.3.3.2.1.1
A table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MdlSEntry

mdlSEntry 1.3.6.1.4.1.164.3.3.2.1.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  MdlSEntry  

mdlSSltIdx 1.3.6.1.4.1.164.3.3.2.1.1.1.1
A unique number to identify a slot position in the DACS. The Kilomux should use enumerated values starting with kmx. For IPmux100 use values 1-13, 20.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER psA(1), psB(2), clA(3), clB(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), psC(20), kmxPsA(101), kmxPsB(102), kmxMlA(103), kmxMlB(104), kmxCl(105), kmxOpt(106), kmxIO1(107), kmxIO2(108), kmxIO3(109), kmxIO4(110), kmxIO5(111), kmxIO6(112), kmxIO7(113), kmxIO8(114), kmxIO9(115), kmxIO10(116), kmxIO11(117), kmxIO12(118), notApplicable(255)  

mdlSCardType 1.3.6.1.4.1.164.3.3.2.1.1.1.2
This attribute indicates the type of the card installed in the specific slot position. Only PS's are possible in the PS slots. Only CL's are possible in the CL slots. Only IO modules are possible in the IO slots. Kmux card type start with the letter k. LA card type start with the letters la.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), empty(2), psAC(10), psDC(11), gCl1(18), gCl2(19), dCl(20), kCl(21), dcl2(22), dcl2Eth(23), kClEth(24), dcl3(25), dcl3Eth(26), d4T1(28), d8T1(29), dT1DSU(30), dT1CSU(31), dE1DSU(32), dE1LTU(33), dE1aDSU(34), dE1aLTU(35), dT1F(36), dE1F(37), d4E1(38), d8E1(39), dE1Hdsl(40), dT1Hdsl(41), dE1HdslS(42), dT1HdslS(43), d16gsdsl(44), d8sl(45), d4slStuC(46), d4slStuR(47), kML1(50), kML2(51), kML3(52), kML4(53), kML5(54), kML6(55), kML7(56), kML8(57), kML10(59), kMLF(60), kML10New(61), kML11RJ45(62), kML11FO(63), kLS1(70), kLS1New(71), kLS2(72), kTRE(80), kMBE(81), kMBENew(82), fLAN(83), kai(90), kdi(91), kdiCH(92), dHS2(100), d8U(101), d16U(102), d4HS(103), d8HS(104), kHS1(110), kHS2(111), kHSU1(112), kHSU2(113), kHS703(114), kVC1EM(130), kVC1FXO(131), kVC1FXS(132), kVC1MEM(133), kVC1MFXO(134), kVC1MFXS(135), kVC1MFXSW(136), kVC2EM(137), kVC2FXO(138), kVC2FXS(139), kVC2s1EM(140), kVC2s1FXO(141), kVC2s1FXS(142), kVC3EM(143), kVC3FXO(144), kVC3FXS(145), kVC3S0(146), kVF1EM(170), kVF1FXO(171), kVF1FXS(172), kVF3EM(173), kVF3FXO(174), kVF3FXS(175), kVF4EM(176), kVF4FXO(177), kVF4FXS(178), kVF4FXSW(179), kVF4S0(180), kVF5PbxE1(181), kVF5E1PbxSlave(182), kVF5PbxT1(183), kVF5T1PbxSlave(184), kVF5PbxE1New(185), kVF5E1PbxSlaveNew(186), kVF5PbxT1New(187), kVF5T1PbxSlaveNew(188), kVF4FXO3(189), kVF4FXS3(190), kVF4NS0(191), kVF6E1s16(192), kVF6E1s31(193), kVF6T1s12(194), kVF6T1s24(195), kVF8EM(196), kVF8FXO(197), kVF8FXS(198), dimETUR(200), dimV35(201), dimRS422(202), dimRS530(203), dimHssi(204), dimX21(205), dim10BaseT(206), dimE1(207), dim100(208), dt3G747(209), dt3(210), dt3f(211), de3(212), de3f(213), dstm1s1(214), dstm1s2(215), fSTM1(216), dstm1(217), dstm1R(218), f2stm1(219), gstm1(220), goc3(221), gstm1D(222), goc3D(223), laSUB(230), laVEM(231), laVFXO(232), laVFXS(233), laV11(234), laV24(235), laV35(236), laT1(237), laT1Vxx(238), laE1(239), laE1Vxx(240), laISDN(241), laVxx(242), laEth(243), laISDNwBU(244), laIsdnNT(245), laIsdnNTwBU(246), laIsdnTE(247), laFXSwBU(248), laFXSs(249), laFXSwBUs(250), laIsdnNTs(251), laIsdnNTwBUs(252), laIsdnTEs(253), laDp(254), laSdsl(255), laSdslDp(256), laAdslA(257), laAdslADp(258), laAdslB(259), laAdslBDp(260), laShdsl(261), laShdslDp(262), laT1b(263), laT1bDp(264), laIsdnTEwBU(265), laIsdnTEwBUs(266), laShdsl4w(267), laShdsl4wDp(268), laEthSwitch(269), serverE1(270), serverT1(271), serverE1Pw(272), serverT1Pw(273), gigabitEth(280), gigabitEth2(281), eth2(282), gigabitEth8(283), eth8(284), channelizedT3Pw1(290), cesT128(300), cesE128(301), cesT1Pw28(302), cesE1Pw28(303), vmxE1VeDe(310), vmxE1VeDi(311), vmxE1ViDe(312), vmxE1ViDi(313), vmxT1VeDe(314), vmxT1VeDi(315), vmxT1ViDe(316), vmxT1ViDi(317), vc12E1UeNe(318), vc12E1UeNi(319), vc12E1UiNe(320), vc12E1UiNi(321), vc12T1UeNe(322), vc12T1UeNi(323), vc12T1UiNe(324), vc12T1UiNi(325), vca16E1UeNe(326), vca16E1UeNi(327), vca16E1UiNe(328), vca16E1UiNi(329), vca16T1UeNe(330), vca16T1UeNi(331), vca16T1UiNe(332), vca16T1UiNi(333), vca12E1UeNe(334), vca12E1UeNi(335), vca12E1UiNe(336), vca12E1UiNi(337), vca12T1UeNe(338), vca12T1UeNi(339), vca12T1UiNe(340), vca12T1UiNi(341), vmg16E1Ue(342), vmg16E1Ui(343), vmg16T1Ue(344), vmg16T1Ui(345), vmg12E1Ue(346), vmg12E1Ui(347), vmg12T1Ue(348), vmg12T1Ui(349)  

mdlSHwVer 1.3.6.1.4.1.164.3.3.2.1.1.1.3
This attribute indicates the Hardware version of the card installed in the specific slot position.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

mdlSSwVer 1.3.6.1.4.1.164.3.3.2.1.1.1.4
This attribute indicates the Software version of the card installed in the specific slot position.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

mdlSAlarmStatus 1.3.6.1.4.1.164.3.3.2.1.1.1.5
Indicates the current alarm state only for card level. This object will be set to: - critical(7): when there is at least one active (ON) critical alarm . - major (3): when there is no active critical alarm, but there is at least one active (ON) major alarm . - minor (4): when there is no active major or critical alarm, but there is at least one active minor alarm. - warning (6): when there is no active major, critical or minor alarm, but there is at least one active warning alarm. - event (5): when there is no active alarm of another type, but there is at least one active event alarm. - off(2): when there is no active (ON) alarm (since last clear operation).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(2), major(3), minor(4), event(5), warning(6), critical(7)  

mdlSAlarmStatusAll 1.3.6.1.4.1.164.3.3.2.1.1.1.6
Indicates the current card alarm state including the lower level: card, port. This object will be set to: - critical(7): when there is at least one active (ON) critical alarm . - major (3): when there is no active critical alarm, but there is at least one active (ON) major alarm . - minor (4): when there is no active major or critical alarm, but there is at least one active minor alarm. - warning (6): when there is no active major, critical or minor alarm, but there is at least one active warning alarm. - event (5): when there is no active alarm of another type, but there is at least one active event alarm. - off(2): when there is no active (ON) alarm (since last clear operation).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(2), major(3), minor(4), event(5), warning(6), critical(7)  

mdlSTestStatus 1.3.6.1.4.1.164.3.3.2.1.1.1.7
This attribute will be on(3) when there is at least one test running on a port of the module; otherwise the value will be off(2).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(2), on(3)  

mdlSHwStatus 1.3.6.1.4.1.164.3.3.2.1.1.1.8
This attribute will be fail(2) when a HW FAIL exists on this module (discovered by periodic self test); otherwise the value will be ok(3).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER fail(2), ok(3)  

mdlSActivity 1.3.6.1.4.1.164.3.3.2.1.1.1.9
notApplicable - when the slot is empty (no module) offline(1) - when the module is not active (redundant) online (2) - when the module is active .
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), offline(2), online(3)  

mdlSAlrClearCmd 1.3.6.1.4.1.164.3.3.2.1.1.1.10
Setting this attribute to ON, will enforce a clear operation on the card level alarms . Upon completion, the value will automatically change to off(2).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

mdlSAlrClearAllCmd 1.3.6.1.4.1.164.3.3.2.1.1.1.11
Setting this attribute to ON, will enforce a clear operation on card and port level alarms . Upon completion, the value will automatically change to off(2).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

mdlSAlrMaskAll 1.3.6.1.4.1.164.3.3.2.1.1.1.12
on(3) - will cause masking of all the card level alarms. These alarms will not be sent to NMS and will not be taken into account for Alarms Status. off(2) - will unmask all card level alarms except those masked via the mdlAlrMaskTable.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

mdlSCmd 1.3.6.1.4.1.164.3.3.2.1.1.1.13
General object for any special command at card level. 0=NotApplicable, for cards that don't support this object. For KML.10(ISDN) card of KM-2100, the object will indicate Manual Call Command in Switch mode. It is applicable only when for KML.10, prtIsdnSwitchMode=manual. KML.10 valid values: '1' = noOp, will be used by agents that do not support this feature or object (old KM agents) '2' = off, Set call command mode to disconnect state. Disconnects the call. '3' = on, Set call command mode to connect state. Connects the call. For DXC IO cards, the object will be used for IO Card Reset HW command: '2' = off, this will be always the Get value for these cards. '3' = on, this is the Set command used to Reset the IO card. Upon completing the operation, the value will automatically change to off(2), by Agent. For Slots that are NOT IO Slots and for empty IO Slots, the Get value will be always '0' (NotApplicable).
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

mdlSReset 1.3.6.1.4.1.164.3.3.2.1.1.1.14
Reset action to be performed on the module.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

mdlSRebuildFrame 1.3.6.1.4.1.164.3.3.2.1.1.1.15
Applicable only for KiloMux Main Link cards only. '2' = off, this will be always the Get value. '3' = on, this is the Set command used to Rebuild the Frame. Upon completing the operation, the value will automatically change to off(2), by Agent.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), off(2), on(3)  

mdlSBackupSwVer 1.3.6.1.4.1.164.3.3.2.1.1.1.16
This attribute indicates the Backup Software version of the card installed in the specific slot position.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

mdlSSecondaryBackupSwVer 1.3.6.1.4.1.164.3.3.2.1.1.1.17
This attribute indicates the Secondary Backup Software version of the card installed in the specific slot position.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

mdlSPiggybackVer 1.3.6.1.4.1.164.3.3.2.1.1.1.18
This attribute indicates the Piggyback version of the card installed in the specific slot position.
Status: current Access: read-only
OBJECT-TYPE    
  SnmpAdminString Size(0..255)  

mdlCTable 1.3.6.1.4.1.164.3.3.2.1.2
A table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MdlCEntry

mdlCEntry 1.3.6.1.4.1.164.3.3.2.1.2.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  MdlCEntry  

mdlCConfigIdx 1.3.6.1.4.1.164.3.3.2.1.2.1.1
This object indicates the Configuration number (1..255) referred. Value of 255 specifies the TmpCnfg (Scratch).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

mdlCSlotIdx 1.3.6.1.4.1.164.3.3.2.1.2.1.2
This object indicates a unique number of the slot position in which the module is inserted. The Kilomux should use enumerated values starting with kmx.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER psA(1), psB(2), clA(3), clB(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), psC(20), kmxPsA(101), kmxPsB(102), kmxMlA(103), kmxMlB(104), kmxCl(105), kmxOpt(106), kmxIO1(107), kmxIO2(108), kmxIO3(109), kmxIO4(110), kmxIO5(111), kmxIO6(112), kmxIO7(113), kmxIO8(114), kmxIO9(115), kmxIO10(116), kmxIO11(117), kmxIO12(118), notApplicable(255)  

mdlCProgCardType 1.3.6.1.4.1.164.3.3.2.1.2.1.3
This object indicates the card type assigned to the specific slot in the common configuration. This object is identical for all the configurations (1..255). Only the TmpCnf(255) might have a different value. The write operation is valid only for the TmpCnfg entry.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), empty(2), psAC(10), psDC(11), gCl1(18), gCl2(19), dCl(20), kCl(21), dcl2(22), dcl2Eth(23), kClEth(24), dcl3(25), dcl3Eth(26), d4T1(28), d8T1(29), dT1DSU(30), dT1CSU(31), dE1DSU(32), dE1LTU(33), dE1aDSU(34), dE1aLTU(35), dT1F(36), dE1F(37), d4E1(38), d8E1(39), dE1Hdsl(40), dT1Hdsl(41), dE1HdslS(42), dT1HdslS(43), d16gsdsl(44), d8sl(45), d4slStuC(46), d4slStuR(47), kML1(50), kML2(51), kML3(52), kML4(53), kML5(54), kML6(55), kML7(56), kML8(57), kML10(59), kMLF(60), kML10New(61), kML11RJ45(62), kML11FO(63), kLS1(70), kLS1New(71), kLS2(72), kTRE(80), kMBE(81), kMBENew(82), fLAN(83), kai(90), kdi(91), kdiCH(92), dHS2(100), d8U(101), d16U(102), d4HS(103), d8HS(104), kHS1(110), kHS2(111), kHSU1(112), kHSU2(113), kHS703(114), kVC1EM(130), kVC1FXO(131), kVC1FXS(132), kVC1MEM(133), kVC1MFXO(134), kVC1MFXS(135), kVC1MFXSW(136), kVC2EM(137), kVC2FXO(138), kVC2FXS(139), kVC2s1EM(140), kVC2s1FXO(141), kVC2s1FXS(142), kVC3EM(143), kVC3FXO(144), kVC3FXS(145), kVC3S0(146), kVF1EM(170), kVF1FXO(171), kVF1FXS(172), kVF3EM(173), kVF3FXO(174), kVF3FXS(175), kVF4EM(176), kVF4FXO(177), kVF4FXS(178), kVF4FXSW(179), kVF4S0(180), kVF5PbxE1(181), kVF5E1PbxSlave(182), kVF5PbxT1(183), kVF5T1PbxSlave(184), kVF5PbxE1New(185), kVF5E1PbxSlaveNew(186), kVF5PbxT1New(187), kVF5T1PbxSlaveNew(188), kVF4FXO3(189), kVF4FXS3(190), kVF4NS0(191), kVF6E1s16(192), kVF6E1s31(193), kVF6T1s12(194), kVF6T1s24(195), kVF8EM(196), kVF8FXO(197), kVF8FXS(198), dimETUR(200), dimV35(201), dimRS422(202), dimRS530(203), dimHssi(204), dimX21(205), dim10BaseT(206), dimE1(207), dim100(208), dt3G747(209), dt3(210), dt3f(211), de3(212), de3f(213), dstm1s1(214), dstm1s2(215), fstm1(216), dstm1(217), dstm1R(218), f2stm1(219), gstm1(220), goc3(221), gstm1D(222), goc3D(223), serverE1(270), serverT1(271), serverE1Pw(272), serverT1Pw(273), gigabitEth(280), gigabitEth2(281), eth2(282), gigabitEth8(283), eth8(284), channelizedT3Pw1(290), cesT128(300), cesE128(301), cesT1Pw28(302), cesE1Pw28(303), vmxE1VeDe(310), vmxE1VeDi(311), vmxE1ViDe(312), vmxE1ViDi(313), vmxT1VeDe(314), vmxT1VeDi(315), vmxT1ViDe(316), vmxT1ViDi(317), vc12E1UeNe(318), vc12E1UeNi(319), vc12E1UiNe(320), vc12E1UiNi(321), vc12T1UeNe(322), vc12T1UeNi(323), vc12T1UiNe(324), vc12T1UiNi(325), vca16E1UeNe(326), vca16E1UeNi(327), vca16E1UiNe(328), vca16E1UiNi(329), vca16T1UeNe(330), vca16T1UeNi(331), vca16T1UiNe(332), vca16T1UiNi(333), vca12E1UeNe(334), vca12E1UeNi(335), vca12E1UiNe(336), vca12E1UiNi(337), vca12T1UeNe(338), vca12T1UeNi(339), vca12T1UiNe(340), vca12T1UiNi(341), vmg16E1Ue(342), vmg16E1Ui(343), vmg16T1Ue(344), vmg16T1Ui(345), vmg12E1Ue(346), vmg12E1Ui(347), vmg12T1Ue(348), vmg12T1Ui(349)  

mdlCNoOfExtPrt 1.3.6.1.4.1.164.3.3.2.1.2.1.4
Number of external ports in the programmed module of the specific slot position
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

mdlCNoOfIntPrt 1.3.6.1.4.1.164.3.3.2.1.2.1.5
Number of internal ports in the programmed module of the specific slot position.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

mdlCParam 1.3.6.1.4.1.164.3.3.2.1.2.1.6
General configuration object at card level (per configuration). NotApplicable=0, for cards that don't support this object. For D8U and D16U cards of DXC, the object will indicate the port on which BERT will be performed. The port can be one of the external ports, any of its associated B1, B2, D ports or no port of the card (None=0). For port indexes see DXC R6 spec. For Gmux-2000, this parameter used for determining the Gigabit ETH exit port
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

mdlAlr 1.3.6.1.4.1.164.3.3.2.1.3
OBJECT IDENTIFIER    

mdlAlrTable 1.3.6.1.4.1.164.3.3.2.1.3.1
The list of card alarms.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MdlAlrEntry

mdlAlrEntry 1.3.6.1.4.1.164.3.3.2.1.3.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  MdlAlrEntry  

mdlAlrIdx 1.3.6.1.4.1.164.3.3.2.1.3.1.1.1
A unique number to identify an entry in the alarm status table. Users should use the get next function to read this table because the indexes are not consecutive
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

mdlAlrSltIdx 1.3.6.1.4.1.164.3.3.2.1.3.1.1.2
This attribute indicates the desired slot position. The Kilomux should use enumerated values starting with kmx.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER psA(1), psB(2), clA(3), clB(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), psC(20), kmxPsA(101), kmxPsB(102), kmxMlA(103), kmxMlB(104), kmxCl(105), kmxOpt(106), kmxIO1(107), kmxIO2(108), kmxIO3(109), kmxIO4(110), kmxIO5(111), kmxIO6(112), kmxIO7(113), kmxIO8(114), kmxIO9(115), kmxIO10(116), kmxIO11(117), kmxIO12(118)  

mdlAlrCode 1.3.6.1.4.1.164.3.3.2.1.3.1.1.3
This object indicates a code related to a specific alarm description. The list of codes and their related descriptions will be sent to NMS request (for display purpose) by alrGenTable.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

mdlAlrState 1.3.6.1.4.1.164.3.3.2.1.3.1.1.4
This object indicates the card alarm severity.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER event(3), minor(4), major(5), warning(6), critical(7)  

mdlAlarmMask 1.3.6.1.4.1.164.3.3.2.1.3.1.1.5
Alarm Mask is : on/off.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(2), on(3)  

mdlAlarmInvert 1.3.6.1.4.1.164.3.3.2.1.3.1.1.6
Alarm Invert is : on/off.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(2), on(3)  

mdlAlarmOnOff 1.3.6.1.4.1.164.3.3.2.1.3.1.1.7
Alarm state is : on/off.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(2), on(3)  

mdlAlarmCounter 1.3.6.1.4.1.164.3.3.2.1.3.1.1.8
A counter - how many times the alarm occured (ON) since last clear operation or since last Reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

mdlAlrMaskTable 1.3.6.1.4.1.164.3.3.2.1.3.2
The list of card masked alarms.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MdlAlrMaskEntry

mdlAlrMaskEntry 1.3.6.1.4.1.164.3.3.2.1.3.2.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  MdlAlrMaskEntry  

mdlAlrMaskSltIdx 1.3.6.1.4.1.164.3.3.2.1.3.2.1.1
This attribute indicates the desired slot position. The Kilomux should use enumerated values starting with kmx.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER psA(1), psB(2), clA(3), clB(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), psC(20), kmxPsA(101), kmxPsB(102), kmxMlA(103), kmxMlB(104), kmxCl(105), kmxOpt(106), kmxIO1(107), kmxIO2(108), kmxIO3(109), kmxIO4(110), kmxIO5(111), kmxIO6(112), kmxIO7(113), kmxIO8(114), kmxIO9(115), kmxIO10(116), kmxIO11(117), kmxIO12(118)  

mdlAlrMask 1.3.6.1.4.1.164.3.3.2.1.3.2.1.2
This object is a mask that indicates which card level alarms are masked. The masked alarms (their bit is set to '1') are neither sent to the manager, nor taken into account for alarm status and LEDs. Bit no. = Alarm code The bits that do not belong to the card level will be 0. This object is applicable only when mdlSAlrMaskAll=off (otherwise all card alarms are masked). Example: When Alarm having the code 8 is masked, the value of this object will be 100 (hex).
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8..10)  

mdlClTable 1.3.6.1.4.1.164.3.3.2.2.1
A table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MdlClEntry

mdlClEntry 1.3.6.1.4.1.164.3.3.2.2.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  MdlClEntry  

mdlClIdx 1.3.6.1.4.1.164.3.3.2.2.1.1.1
This object indicates the Cl slot referred.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER clA(3), clB(4)  

mdlClSwchStatus 1.3.6.1.4.1.164.3.3.2.2.1.1.2
This object indicates the status of the switches on the referred DCL card. Each switch is represented by a bit. The status is a sum of 2**n, according to the bits. There are 4 switches: bit 0 SP-PAR (LSB) '1' - Default parameters bit 1 PSWRD '1' - Password=default '0' - Password=user selected bit 2 DB-INIT '1' - DB initiated with default '0' - DB initiated with NVRAM contents bit 3 PC-SP (MSB) '1' - Management by terminal only '0' - Management by NMS Example: If SP-PAR and PSWRD bits are set ('1'), the value will be 3 (2**1 + 2**0). When the status of the switches is unknown, the value of this object will be 255.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

mdlClLastFlipDate 1.3.6.1.4.1.164.3.3.2.2.1.1.3
Date when last flip occured. The format would be as specified by the sysSDateFormat.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

mdlClLastFlipTime 1.3.6.1.4.1.164.3.3.2.2.1.1.4
Time when last flip occured.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

mdlClLastFlipCause 1.3.6.1.4.1.164.3.3.2.2.1.1.5
The cause of last flip.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

mdlPsTable 1.3.6.1.4.1.164.3.3.2.3.1
A table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MdlPsEntry

mdlPsEntry 1.3.6.1.4.1.164.3.3.2.3.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  MdlPsEntry  

mdlPsIdx 1.3.6.1.4.1.164.3.3.2.3.1.1.1
This object indicates the PS card referred.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER psA(1), psB(2)  

mdlPsStatus 1.3.6.1.4.1.164.3.3.2.3.1.1.2
This object indicates the status of the PS card.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notActive(1), active(2)  

mdlPsTestResult 1.3.6.1.4.1.164.3.3.2.3.1.1.3
This object indicates the result of the PS card test. ok (1) - the test passed successfully. f12V (2) - 12V FAIL was detected f5V (3) - 5V FAIL was detected.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), f12V(2), f5V(3)  

prtGen 1.3.6.1.4.1.164.3.3.3.1
OBJECT IDENTIFIER    

prtT1E1 1.3.6.1.4.1.164.3.3.3.2
OBJECT IDENTIFIER    

prtHS 1.3.6.1.4.1.164.3.3.3.3
OBJECT IDENTIFIER    

prtSP 1.3.6.1.4.1.164.3.3.3.4
OBJECT IDENTIFIER    

prtDim 1.3.6.1.4.1.164.3.3.3.5
OBJECT IDENTIFIER    

prtI 1.3.6.1.4.1.164.3.3.3.6
OBJECT IDENTIFIER    

prtHdsl 1.3.6.1.4.1.164.3.3.3.7
OBJECT IDENTIFIER    

prtT3E3 1.3.6.1.4.1.164.3.3.3.8
OBJECT IDENTIFIER    

prtGenParamTable 1.3.6.1.4.1.164.3.3.3.1.1
A table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtGenEntry

prtGenEntry 1.3.6.1.4.1.164.3.3.3.1.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtGenEntry  

prtGenPrtIdx 1.3.6.1.4.1.164.3.3.3.1.1.1.1
This attribute indicates a unique number to identify a port. The valid port number depends on the IO slot no., the installed card type and the port type: outside/external, inside/internal. In the Kilomux, the port index is calculated as follows: 100*Slot+Ch. The external Ch numbers are 1..10, and the internal Ch numbers are 11..20. In the DXC : - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card in odd or even numbers, as follows: * For the outside/external ports, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The inside/internal ports, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 .
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtGenSlt 1.3.6.1.4.1.164.3.3.3.1.1.1.2
This attribute indicates a unique number to identify the slot where the card is inserted in. When the unit is stand-alone, this object is not applicable and 255 will be used. The Kilomux should use the enumerated starting with kmx.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), kmxMlA(103), kmxMlB(104), kmxCl(105), kmxOpt(106), kmxIO1(107), kmxIO2(108), kmxIO3(109), kmxIO4(110), kmxIO5(111), kmxIO6(112), kmxIO7(113), kmxIO8(114), kmxIO9(115), kmxIO10(116), kmxIO11(117), kmxIO12(118), standAlone(255)  

prtGenExtInt 1.3.6.1.4.1.164.3.3.3.1.1.1.3
This attribute describes the type of the designated port. Exteral port is a port with a physical connector. Internal port might be of two types, one is a composite port which collects data of a few external ports into a common bandwidth (usually routed trough DS1 link); the other type is internal ports which get only part of external port data (usually a few DS0's). In the Kilomux-2100, the internal(3) value is used for composite channels or sub-channels of an ISDN Ch.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER external(2), internal(3)  

prtGenIfIndex 1.3.6.1.4.1.164.3.3.3.1.1.1.4
This attribute indicates the unique interface number assigned to the port. The specific interface of this attribute is the same as the interface identified by the value of ifindex in MIB-II.If there is no interface for the specific prtIdx, the value will be '7fffffff'h.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtGenActiveStatus 1.3.6.1.4.1.164.3.3.3.1.1.1.5
This attribute describes the activity status of the port. unknown(1) indicates that the information is not supported. notUsed(2) indicates that the port is not connected according to the active config. offLine(3) indicates that the port is down (not working) due to any problem. onLine (4) indicates that the port is up (working) offLineRedundancy(5) indicates that the port is down because it is a redundant port. onLineRedundancy (6) indicates that this is a redundant port which is up and works as the active link.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), notUsed(2), offLine(3), onLine(4), offLineRedundancy(5), onLineRedundancy(6)  

prtGenAlrStatus 1.3.6.1.4.1.164.3.3.3.1.1.1.6
Indicates the alarm state at port (ch) agent level. This object will be: - critical(7): when there is at least one active (ON) critical alarm . - major (3): when there is no active critical alarm, but there is at least one active (ON) major alarm . - minor (4): when there is no active major or critical alarm, but there is at least one active minor alarm. - warning (6): when there is no active major, critical or minor alarm, but there is at least one active warning alarm. - event (5): when there is no active alarm of another type, but there is at least one active event alarm. - off(2): when there is no active (ON) alarm (since last clear operation).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(2), major(3), minor(4), event(5), warning(6), critical(7)  

prtGenTestStatus 1.3.6.1.4.1.164.3.3.3.1.1.1.7
This attribute will be on(3) when there is at least one test in progress (running) on the port; otherwise the value will be off(2).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtGenTestMask 1.3.6.1.4.1.164.3.3.3.1.1.1.8
This is a mask which indicates which tests from the 'prtGenTestCmd' list are allowed for the selected port. If a specific test is allowed, its respective bit will be SET in the mask : TEST BIT ----------- --- localLoop 1 remoteLoop 2 bert 3 plb 4 inband 5 prbs 8 loop2-v54 (RLB) 9 loop3-v54 (LLB) 10 Tone injection 13 Tx-plb 14 Tx-llb 15 DTE loop (HSSI) 16 HDSL-Tx-Inband 20 HDSL-Rx-Inband 21 Monitor 22 (test port) User Line Loopback 23 Rem-Loop-on-Rem-Unit 25 LBBD 26 LB1 27 LB2 28 BERT-on-Rem-Unit 29 TS Remote Loop 30 LLB-on-Rem-Unit 31 e.g : If the return value is 3 -> 0000000000000011 -> Bits 1 & 2 are set -> the allowed tests are : local-loop remote-loop
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtGenTestCmd 1.3.6.1.4.1.164.3.3.3.1.1.1.9
Setting this object to a value as detailed furter on (except 0) will initiate a test on the specific port, if the operation is allowed (according to TestMask). If the operation is not allowed, the mux will ignore the operation. The test/s requested will be set according to the respective bit: TEST BIT ----------- --- localLoop 1 remoteLoop 2 bert 3 plb 4 inband 5 prbs 8 loop2-v54 (RLB) 9 loop3-v54 (LLB) 10 Tone injection 13 Tx-plb 14 Tx-llb 15 DTE loop (HSSI) 16 HDSL-Tx-Inband 20 HDSL-Rx-Inband 21 Monitor 22 (test port) User Line Loopback 23 Rem-Loop-on-Rem-Unit 25 LBBD 26 LB1 27 LB2 28 BERT-on-Rem-Unit 29 TS Remote Loop 30 LLB-on-Rem-Unit 31 e.g : If the requested value is 3 -> 0000000000000011 -> Bits 1 & 2 are set -> the requested tests are : local-loop remote-loop Setting this object to stop (value=0 ; all bits are 0), will stop all the user requested tests running on the selected port; it will NOT stop the tests initiated by the system.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtGenTestRunning 1.3.6.1.4.1.164.3.3.3.1.1.1.10
This object indicates which tests are running currently on the selected port (initiated by user and/or by the system). If a specific test is currently running on the port, its respective bit will be SET: TEST BIT ----------- --- localLoop 1 remoteLoop 2 bert 3 plb 4 llb 5 txInband 6 rxInband 7 prbs 8 loop2-v54 (RLB) 9 loop3-v54 (LLB) 10 DDS DSU loop 11 DDS CSU loop 12 Tone injection 13 Tx-plb 14 Tx-llb 15 DTE loop (HSSI) 16 Local DTE loop (HSSI)17 Local Line loop (HSSI)18 Remote Line loop (HSSI)19 HDSL-Tx-Inband 20 HDSL-Rx-Inband 21 Monitor 22 (test port) User Line Loopback 23 Network Line Loopback 24 Rem-Loop-on-Rem-Unit 25 LBBD 26 LB1 27 LB2 28 BERT-on-Rem-Unit 29 TS Remote Loop 30 LLB-on-Rem-Unit 31 e.g : If the return value is 3 -> 0000000000000011 -> Bits 1 & 2 are set -> the running tests are : local-loop remote-loop llb (Bit 5) - can be initiated by system only!
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtGenType 1.3.6.1.4.1.164.3.3.3.1.1.1.11
This object describes the type of the selected port. idsl - applicable for external ports of HS-U cards (of DXC) when interface is LT-1.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), t1(2), e1(3), hs(4), t1Csu(5), t1Dsu(6), e1Ltu(7), e1Dsu(8), hdsl(9), sp(10), t1F(11), e1F(12), dim(13), isdn(14), t3(15), e3(16), t3f(17), e3f(18), idsl(19), stm1(20), vc4(21), vc12(22), msdsl(23), vc11(24), vc3(25), soh(26), eth(27), shdsl(28), other(255)  

prtGenInterfaceType 1.3.6.1.4.1.164.3.3.3.1.1.1.12
This attribute indicates a unique HW interface type of the selected port. Examples: - for T1 cards: DSU, CSU - for E1 cards: DSU, LTU - for HS cards: v35, rs422, x21 etc...
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

prtGenAlrClearCmd 1.3.6.1.4.1.164.3.3.3.1.1.1.13
Setting this attribute to ON, will enforce a clear operation on the port level alarms . Upon completion, the value will automatically change to off(2). noOp - will be used by agents that do not support this feature or object.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noOp(1), off(2), on(3)  

prtGenAlrMaskAll 1.3.6.1.4.1.164.3.3.3.1.1.1.14
on(3) - will mask all the alarms of the selected port off(2)- will unmask all alarms of the selected port except the ones selected by the prtAlrMaskTable. noOp - will be used by agents that do not support this feature or object.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noOp(1), off(2), on(3)  

prtGenParamStatus 1.3.6.1.4.1.164.3.3.3.1.1.1.15
This object indicates Status of parameters specific to the selected port. - For a port that has no special status or is supported by prtSExHsfStatTable - 1 Octet: 00hex - For HS cards (Dxc cards) - 1 octet: Bit 7 (MSB)..Bit 2 = 0 (NA) Bit 0 and 1 indicates RTS control signal state: Bit 1: '1'=active ; '0'=notActive Bit 0 (LSB): '1'=unknown ; '0'=NA - For HS-U/1 external port (MP card, used in FCD-M) - 1 Octet: Bit 7 6 5 4 3 2 1 0 LSB |________| |__| |__| spare modem sync modem: 00 = other sync: 00 = not sync 01 = unknown 01 = sync 10 = ASMi-31/2 10 = reserved 11 = reserved 11 = reserved - For VC-6, VC-12, VC-12/6 external ports - 1 Octet : Bit 7 (MSB)..Bit 2 = 0 (NA) Bit 1: Tx Signaling '1'=On ; '0'=Off Bit 0 (LSB): Rx Signaling '1'=On ; '0'=Off - For VC-2/R2(FXS) external ports - 1 Octet : Bit - 7 6 5 4 3 2 1 0 |_| |_________| Call Call State Direction Bit 7 (MSB) and Bit 6 : Call Direction 00 - Incoming 01 - Outgoing Bit 5..Bit 0: Call State 000000 - Idle 000001 - Seized 000010 - Both-Way Conflict 000011 - Seizure Ack 000100 - Answered 000101 - Clear Backward 000110 - Clear Forward 000111 - Blocked 001000 - Fault 001001 - Fault 3 001010 - Fault 4 001011 - Fault 5 001100 - Fault 6 001101 - Fault 7 - For ML-20 external port - 3 Octets : - 1 MS Octet will represent the Real Rate used: Bit - 7 6 5 4 3 2 1 0 |___| |_______| spare Rate Valid values: 0..31, meaning 0..31x64Kbps Invalid values: 32..255. - 2 LS Octets will represent the Status of 7 Control Signals: Signal - --- CTS DSR DCD RJ TM DTR RTS Bit - 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Octet - 2 3 (LS) '---' will always have the value 00 Rest of the Signals (2 bits each) can have the following values: 00=NA ; 01=Unused ; 10=Off ; 11=On - For ML-H/E1, ML-H/1/E1, ML-H/S/E1 internal port - 1 Octet Bit - 7 6 5 4 3 2 1 0 |___________| spare Mode of Operation Mode of Operation: '1'=Central ; '0'=Remote - For KM2100, KVF.5 cards - indicates the status of A and B signaling for each internal channel. 1 Octet: Bit - 7 6 5 4 3 2 1 0 |_____| |_| |_| spare B A Bit 0 (LSB) and Bit 1 : A status Bit 2 and Bit 3 : B status 00 - Off 01 - On 11 - Unknown - For FCD-W, NETWORK and USER ports - 1 Octet Status of Control Signals: '1'=On ; '0'=Off or when not applicable Bit - 7 6 5 4 3 2 1 0 Bit 7 (MSB) - Signal Loss (applicable only for G.703 interface) Bit 6 - CONTROL (applicable only for X.21 interface) Bit 5 - INDICATION (applicable only for X.21 interface) Bit 4 - DSR (applicable only for V.35 interface) Bit 3 - RTS (applicable only for V.35 interface) Bit 2 - CTS (applicable only for V.35 interface) Bit 1 - DTR (applicable only for V.35 interface) Bit 0 - DCD (applicable only for V.35 interface) - For DXC R6 , D8U, D16U External ports - 1 Octet Bit 7 6 5 4 3 2 1 0 LSB |________| |__| |__| spare modem sync modem: 00 = other sync: 00 = not sync 01 = unknown 01 = sync 10 = ASMi-31/2 10 = reserved 11 = reserved 11 = reserved - For DXC DE1-HDSL, DT1-HDSL, D16GSDSL, D8SL External ports - 2 Octets MSB octet: far-end modem channel interface LSB octet: Sub Link existence (Y/N), far-end modem type, synchronization with far-end modem MSB octet: 0000 0000 = no interface 0000 0001 = db15 (X21) 0000 0010 = IR-IP 0000 0011 = IR-ETH-Q 0000 0100 = V35 0000 0101 = ETH-RJ45 0000 0110 = G703 0000 0111 = db25 (RS530) 0000 1000 = ETH-BNC 0000 1001 = E1(Balanced) 0000 1010 = E1(Unbalanced) 0000 1011 = IR-ETH-QN Rest of the combinations: reserved LSB octet: Bit 7 6 5 4 3 2 1 0 LSB | |___________| |__| SL modem sync or Box material SL: modem: 00000 = other sync: 00 = not sync 0=not exist 00001 = unknown 01 = sync 1=exists 00010 = ASMi-31/2 10 = reserved 00011 = HCD-E1 11 = reserved Box material 00100 = HTU-E1 (for D8SL card): 00101 = HTU-2 0=metal 00110 = ASMi-52 SA/2W/Slave 1=plastic 00111 = ASMi-52 SA/2W/Master 01000 = ASMi-52/CQ card of LRS-24 01001 = ASMi-52/CD card of LRS-24 01010 = D16GSDSL card of DXC-3000 01011 = LRS-52 01100 = FCD 01110 = D8GSDSL card of DXC-3000 01111 = ASMi-52A Rest = reserved
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

prtGenRdnStatus 1.3.6.1.4.1.164.3.3.3.1.1.1.16
This object indicates if this port is part of a redundant pair and in this case, if it is On or Off. none(1) - No redundancy or Not Applicable off (2) - the port is part of a redundant pair and it is Off from Redundancy point of view (not the port used). on (3) - the port is part of a redundant pair and it is On from Redundancy point of view (it is the port used).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(1), off(2), on(3)  

prtGenTestMaskXP 1.3.6.1.4.1.164.3.3.3.1.1.1.17
This is an Expanded test mask of the prtGenTestMask object. The prtGenTestMask object reached its maximum, being an Integer with 31 bits. This object indicates which tests from the 'prtGenTestCmdXP' list are allowed for the selected port. If a specific test is allowed, its respective bit will be SET in the mask : TEST BIT ----------- --- localLoop 1 =LSB remoteLoop 2 bert 3 plb 4 inband 5 prbs 8 loop2-v54 (RLB) 9 loop3-v54 (LLB) 10 Tone injection 13 Tx-plb 14 Tx-llb 15 DTE loop (HSSI) 16 HDSL-Tx-Inband 20 HDSL-Rx-Inband 21 Monitor 22 (test port) User Line Loopback 23 Rem-Loop-on-Rem-Unit 25 LBBD 26 LB1 27 LB2 28 BERT-on-Rem-Unit 29 TS Remote Loop 30 LLB-on-Rem-Unit 31 Downstream-AIS 32 Upstream-AIS 33 Send-RDI 34 Test Per TS 35 e.g : If the return value is 00000003 hex -> Bits 1 & 2 are set -> the allowed tests are : local-loop remote-loop
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

prtGenTestCmdXP 1.3.6.1.4.1.164.3.3.3.1.1.1.18
This is an Expanded test command of the prtGenTestCmd object. The prtGenTestCmd object reached its maximum, being an Integer with 31 bits. Setting this object to a value as detailed furter on (except 0) will initiate a test on the specific port, if the operation is allowed (according to TestMaskXP). If the operation is not allowed, the mux will ignore the operation. The test/s requested will be set according to the respective bit: TEST BIT ----------- --- localLoop 1 =LSB remoteLoop 2 bert 3 plb 4 inband 5 prbs 8 loop2-v54 (RLB) 9 loop3-v54 (LLB) 10 Tone injection 13 Tx-plb 14 Tx-llb 15 DTE loop (HSSI) 16 HDSL-Tx-Inband 20 HDSL-Rx-Inband 21 Monitor 22 (test port) User Line Loopback 23 Rem-Loop-on-Rem-Unit 25 LBBD 26 LB1 27 LB2 28 BERT-on-Rem-Unit 29 TS Remote Loop 30 LLB-on-Rem-Unit 31 Downstream-AIS 32 Upstream-AIS 33 Send-RDI 34 Test Per TS 35 e.g : If the requested value is 00000003 hex -> Bits 1 & 2 are set -> the requested tests are : local-loop remote-loop Setting this object to stop (value=0 ; all bits are 0), will stop all the user requested tests running on the selected port; it will NOT stop the tests initiated by the system.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

prtGenTestRunningXP 1.3.6.1.4.1.164.3.3.3.1.1.1.19
This is an Expanded object of the prtGenTestRunning object. The prtGenTestRunning object reached its maximum, being an Integer with 31 bits. This object indicates which tests are running currently on the selected port (initiated by user and/or by the system). If a specific test is currently running on the port, its respective bit will be SET: TEST BIT ----------- --- localLoop 1 =LSB remoteLoop 2 bert 3 plb 4 llb 5 txInband 6 rxInband 7 prbs 8 loop2-v54 (RLB) 9 loop3-v54 (LLB) 10 DDS DSU loop 11 DDS CSU loop 12 Tone injection 13 Tx-plb 14 Tx-llb 15 DTE loop (HSSI) 16 Local DTE loop (HSSI)17 Local Line loop (HSSI)18 Remote Line loop (HSSI)19 HDSL-Tx-Inband 20 HDSL-Rx-Inband 21 Monitor 22 (test port) User Line Loopback 23 Network Line Loopback 24 Rem-Loop-on-Rem-Unit 25 LBBD 26 LB1 27 LB2 28 BERT-on-Rem-Unit 29 TS Remote Loop 30 LLB-on-Rem-Unit 31 Downstream-AIS 32 Upstream-AIS 33 Send-RDI 34 Test Per TS 35 e.g : If the return value is 00000003 hex -> Bits 1 & 2 are set -> the running tests are : local-loop remote-loop llb (Bit 5) - can be initiated by system only!
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

prtGenTestDurationTable 1.3.6.1.4.1.164.3.3.3.1.2
A table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtGenTestDurationEntry

prtGenTestDurationEntry 1.3.6.1.4.1.164.3.3.3.1.2.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtGenTestDurationEntry  

prtGenTestPrtIdx 1.3.6.1.4.1.164.3.3.3.1.2.1.1
This attribute indicates a unique number to identify a port. The valid port number depends on the IO slot no., the installed card type and the port type: outside/external, inside/internal. In the Kilomux, the port index is calculated as follows: 100*Slot+Ch. The external Ch numbers are 1..10, and the internal Ch numbers are 11..20. In the DXC : - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card in odd or even numbers, as follows: * For the outside/external ports, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The inside/internal ports, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 .
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtGenTestIdx 1.3.6.1.4.1.164.3.3.3.1.2.1.2
This attribute indicates the test, the duration refers.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER localLoop(1), remoteLoop(2), bert(3), plb(4), rlb(5), llb(6), toneInjection(7), txInband(8), rxInband(9), remLoopOnRemUnit(10), bertOnRemUnit(11), llbOnRemUnit(12), txPlb(14), txLlb(15), dteLoop(16), hdslTxInband(20), hdslRxInband(21), monitor(22), userLineLoopback(23), lbbd(26), lb1(27), lb2(28), tsRemoteLoop(30), downstreamAis(32), upstreamAis(33), sendRdi(34)  

prtGenTestDuration 1.3.6.1.4.1.164.3.3.3.1.2.1.3
This attribute indicates the maximum duration of executing a test on the specific port. This entry applies to the specified test . The resolution will be a minute, and the maximum duration is limited to 30 minutes . A zero value specifies no time limitation. When the test isn't active the agent initiates this object to 2 min. when the duration is needed and to 0 if it's not required.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtGenTsTable 1.3.6.1.4.1.164.3.3.3.1.3
The write operation into the Table's Objects is valid only for the TmpCnfg entry (Scratch),exept some products which enable direct writing to the ActiveCnfg. This is written in the respective product's spec.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtGenTsEntry

prtGenTsEntry 1.3.6.1.4.1.164.3.3.3.1.3.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtGenTsEntry  

prtGenTsCnfgIdx 1.3.6.1.4.1.164.3.3.3.1.3.1.1
This attribute indicates the Idx of the Cnfg(1..255) being accessed. Idx of 255 relates to the TmpCnfg.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

prtGenTsPrtIdx 1.3.6.1.4.1.164.3.3.3.1.3.1.2
This attribute indicates a unique port number. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside, SP. In the DXC : - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card in odd or even numbers, as follows: * For the outside/external ports, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The inside/internal ports, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 .
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtGenTsIdx 1.3.6.1.4.1.164.3.3.3.1.3.1.3
This attribute indicates a unique time slot position. The valid time slots are 1..25 for T1 Card (25=Fbit) 0..31 for E1 or HS Card . In G732S-E1 lines time slot 16 is not valid for data, it is dedicated for multiframe synchronization bits and voice signaling.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtGenTsType 1.3.6.1.4.1.164.3.3.3.1.3.1.4
The type of Timeslot. If the source or destination port is an HS port,'TS Type' must be 'data'. nc - means that this TimeSlot is not connected. voice, data, vcMP - also mean that this TS is connected. mng - means that this TS is dedicated to Management (not connected to another port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), voice(2), data(3), vcMP(4), nc(5), mng(6)  

prtGenTsIConPrt 1.3.6.1.4.1.164.3.3.3.1.3.1.5
This attribute indicates the internally (In Mux) connected port. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside, SP. * The outside ports will be the T1/E1 cards ports. The convention used will be (for DXC): - first two digits will be: (IO slot number+10) for a stand-alone unit, the IO slot will be considered 1. - last one/two digits will be the port number within the card, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The inside ports will be for example, the HS cards ports. The convention used will be (for DXC): - first two digits will be: (IO slot number+10) for a stand-alone unit, the IO slot will be considered 1. - last one/two digits will be the port number within the card, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 . * noConnection - will be indicated as 10 for DXC and FCD-E1/T1. - will be indicated as 100 for FCD-E1/I and SMODs. * Split TS (same TS is Split to several ports) - 11. * notApplicable- will be indicated as 100 for LRS IMODs. All HS port's timeslots must have the same destination port.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtGenTsIConTs 1.3.6.1.4.1.164.3.3.3.1.3.1.6
This attribute indicates a unique time slot position. The valid time slots are 1..25 for T1 Card (25=Fbit) 0..31 for E1 (or HS) Card. In G732S-E1 lines time slot 16 is not valid for data, it is dedicated for multiframe synchronization bits and voice signaling. * For DXC: All HS port's timeslots must start with Timeslot no.1
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtAlr 1.3.6.1.4.1.164.3.3.3.1.4
OBJECT IDENTIFIER    

prtSAlarmTable 1.3.6.1.4.1.164.3.3.3.1.4.1
A table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtSAlarmEntry

prtSAlarmEntry 1.3.6.1.4.1.164.3.3.3.1.4.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtSAlarmEntry  

prtSAlarmIdx 1.3.6.1.4.1.164.3.3.3.1.4.1.1.1
A unique number to identify an entry in the alarm status table. Users should use the get next function to read this table because the indexes are not consecutive.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtSAlarmPrtIdx 1.3.6.1.4.1.164.3.3.3.1.4.1.1.2
This attribute indicates a unique number to identify a port. The valid port number depends on the IO slot no., the installed card type and the port type: outside/external, inside/internal. In the Kilomux, the port index is calculated as follows: 100*Slot+Ch. The external Ch numbers are 1..10, and the internal Ch numbers are 11..20. In the DXC : - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card in odd or even numbers, as follows: * For the outside/external ports, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The inside/internal ports, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 .
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtSAlarmCode 1.3.6.1.4.1.164.3.3.3.1.4.1.1.3
This object indicates a code related to a specific alarm description. The list of codes and their related descriptions will be sent to NMS request (for display purpose) by alrGenTable.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtSAlarmState 1.3.6.1.4.1.164.3.3.3.1.4.1.1.4
This object indicates the port alarm severity.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER event(3), minor(4), major(5), warning(6), critical(7)  

prtSAlarmMask 1.3.6.1.4.1.164.3.3.3.1.4.1.1.5
Alarm Mask is : on/off.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtSAlarmInvert 1.3.6.1.4.1.164.3.3.3.1.4.1.1.6
Alarm Invert is : on/off.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtSAlarmOnOff 1.3.6.1.4.1.164.3.3.3.1.4.1.1.7
Alarm state is : on/off.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtSAlarmCounter 1.3.6.1.4.1.164.3.3.3.1.4.1.1.8
A counter - how many times the alarm occured (ON) since last clear operation or since last Reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtAlrMaskTable 1.3.6.1.4.1.164.3.3.3.1.4.2
A table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtAlrMaskEntry

prtAlrMaskEntry 1.3.6.1.4.1.164.3.3.3.1.4.2.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtAlrMaskEntry  

prtAlrMaskPrtIdx 1.3.6.1.4.1.164.3.3.3.1.4.2.1.1
This attribute indicates a unique number to identify a port. The valid port number depends on the IO slot no., the installed card type and the port type: outside/external, inside/internal. In the Kilomux, the port index is calculated as follows: 100*Slot+Ch. The external Ch numbers are 1..10, and the internal Ch numbers are 11..20. In the DXC : - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card in odd or even numbers, as follows: * For the outside/external ports, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The inside/internal ports, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 .
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtAlrMask 1.3.6.1.4.1.164.3.3.3.1.4.2.1.2
This object is a mask that indicates which port level alarms are masked. The masked alarms (their bit is set to '1') are neither sent to the manager, nor taken into account for alarm status and LEDs. Bit no. = Alarm code The bits that do not belong to the port level will be 0. This object is applicable only when prtGenAlrMaskAll=off (otherwise all port alarms are masked). Example: When Alarms having the codes 31 and 40 are masked, the value of this object will be 10080000000 (hex).
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8)  

prtBertTable 1.3.6.1.4.1.164.3.3.3.1.5
This table includes the BERT parameters, counters and commands. The configurable parameters: - prtBertPattern - prtBertInjectRate - prtBertTs are not Set per configuration (same for all Configurations) but start being applied by the Agent only upon successful Update/Download operation. Therefore, Set will enter the values to the Temporary Configuration of the agent, while Get will get the values of the Active Configuration.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtBertEntry

prtBertEntry 1.3.6.1.4.1.164.3.3.3.1.5.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtBertEntry  

prtBertPrtIdx 1.3.6.1.4.1.164.3.3.3.1.5.1.1
This attribute indicates a unique number to identify a port. The valid port number depends on the IO slot no., the installed card type and the port type: outside/external, inside/internal. In the Kilomux, the port index is calculated as follows: 100*Slot+Ch. The external Ch numbers are 1..10, and the internal Ch numbers are 11..20. In the DXC : - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card in odd or even numbers, as follows: * For the outside/external ports, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The inside/internal ports, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 . In the MP : - first two digits will be: (IO slot number+10) - last one/two digits will be according to the external port number within the card: exPrt1 -> 1 exPrt2 -> 3 exPrt3 -> 5 exPrt4 -> 7 .
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtBertPattern 1.3.6.1.4.1.164.3.3.3.1.5.1.2
This object indicates the pattern of the BERT. p2Exxm1 = 2Exx-1. pxx = pattern xx. This object is the same for all configurations. notApplicable - when this object is not supported.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER p2E3m1(1), p2E4m1(2), p2E5m1(3), p2E6m1(4), p2E7m1(5), p511(6), p2E10m1(7), p2047(8), p2E15m1(9), p2E17m1(10), p2E18m1(11), p2E20m1(12), qrss(13), p2E21m1(14), p2E22m1(15), p2E23m1(16), p2E25m1(17), p2E28m1(18), p2E29m1(19), p2E31m1(20), p2E32m1(21), rj011(22), p63(23), p1M7S(24), p1S7M(25), alternate(26), mark(27), space(28), p2E11m1(29), notApplicable(255)  

prtBertInjectRate 1.3.6.1.4.1.164.3.3.3.1.5.1.3
This object indicates the error rate injection of the BERT. r10Emx = 10E-x This object is the same for all configurations. single - single error injection. notApplicable - when this object is not supported.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noError(1), r10Em1(2), r10Em2(3), r10Em3(4), r10Em4(5), r10Em5(6), r10Em6(7), r10Em7(8), single(9), notApplicable(255)  

prtBertInjectErrRateCmd 1.3.6.1.4.1.164.3.3.3.1.5.1.4
This object controls activation/deactivation of the Error Rate Injection during BERT.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtBertInjectSingleErrCmd 1.3.6.1.4.1.164.3.3.3.1.5.1.5
This object enables to initiate a Single Error Injection during BERT (on). Upon completion, the value will automatically change to off(2).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtBertRunTime 1.3.6.1.4.1.164.3.3.3.1.5.1.6
This object indicates how much time (seconds) passed since BERT started to run.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtBertESs 1.3.6.1.4.1.164.3.3.3.1.5.1.7
How many Errored Seconds were detected since BERT started to run. Counter for Kmux and MP.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtBertSyncLoss 1.3.6.1.4.1.164.3.3.3.1.5.1.8
How many times Sync Loss was detected since BERT started to run. For some products: number of seconds in which Sync Loss occured since BERT started to run. See product specification.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtBertErrorBits 1.3.6.1.4.1.164.3.3.3.1.5.1.9
How many Error Bits were detected since BERT started to run.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtBertClearCounters 1.3.6.1.4.1.164.3.3.3.1.5.1.10
Setting this object to ON, will enforce a clear operation of some BERT Counters. Upon completion, the value will automatically change to off(2).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtBertSyncStatus 1.3.6.1.4.1.164.3.3.3.1.5.1.11
Sync Status while BERT runs.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), syncLoss(2), sync(3)  

prtBertTs 1.3.6.1.4.1.164.3.3.3.1.5.1.12
This object indicates on which TSs of the selected port, BERT should be applied. Each Bit of the Octet represents a TS: 31 ......0 MSB LSB Bit 0 will not be used. If the bit value is '1' - BERT should be applied on this TS. For a T1 port, the valid raised bits ('1') are: 1..25. For an E1 port, the valid raised bits ('1') are: 1..31. Agents that do not support this feature will send SIZE 0.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..4)  

prtBertResult 1.3.6.1.4.1.164.3.3.3.1.5.1.13
This object indicates Result of BERT for the selected port (number of error bits divided to the total number of data bits.) Applicable only if BERT is running on this port Agents that do not support this feature will send SIZE 0.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

prtBertTxBits 1.3.6.1.4.1.164.3.3.3.1.5.1.14
How many data bits were transmitted since BERT started to run, or since last counter clear (prtBertClearCounters set to on).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtBertRxBits 1.3.6.1.4.1.164.3.3.3.1.5.1.15
How many data bits were Received since BERT started to run, or since last counter clear (prtBertClearCounters set to on).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtBertTxErrorBits 1.3.6.1.4.1.164.3.3.3.1.5.1.16
Number of injected error bits since BERT started to run, or since last counter clear (prtBertClearCounters set to on).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtMonTable 1.3.6.1.4.1.164.3.3.3.1.6
For DXC, the write operation into the Table's Objects is valid only for the TmpCnfg entry (Scratch).
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtMonEntry

prtMonEntry 1.3.6.1.4.1.164.3.3.3.1.6.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtMonEntry  

prtMonCnfgIdx 1.3.6.1.4.1.164.3.3.3.1.6.1.1
This object indicates the Idx of the Cnfg(1..255) being accessed. Idx of 255 relates to the TmpCnfg. For products that do not support configurations, 1 will be always used.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

prtMonitoringIdx 1.3.6.1.4.1.164.3.3.3.1.6.1.2
This object indicates the Monitoring Port Index. For DXC: The valid port number depends on the IO slot no., the installed card type and the port type: external, internal. * The external ports will according to the convention (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The internal ports will be according to the convention (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 . For Optimux-T3: 255 (Not Applicable) will be always used. The Monitoring port is always the Station Clock (not considered an interface).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtMonitoringEnable 1.3.6.1.4.1.164.3.3.3.1.6.1.3
This object indicates if the prtMonitoringIdx is configured as a monitoring port or not. disabled = the port is NOT configured to monitor. Setting this object to this value will cause reset (to 0) of the prtMonitoringTSs and prtMonitoredTSs objects. enabled = the port IS configured to monitor. For Optimux-T3: always enabled (RO supported).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

prtMonitoringTSs 1.3.6.1.4.1.164.3.3.3.1.6.1.4
This object indicates which TSs of the Monitoring port, the test equipment should monitor. Each Bit of the Octet represents a TS: 31 ......0 MSB LSB Bit 0 will not be used. If the bit value is '1' - this TS should be monitored. For a T1 port, the valid raised bits ('1') are: 1..24. For an E1 port, the valid raised bits ('1') are: 1..31. Default: all bits='0' Agents that do not support this feature will send SIZE 0. This object can be Set as described only if prtMonitoringEnable=enabled.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..4)  

prtMonitoredPort 1.3.6.1.4.1.164.3.3.3.1.6.1.5
This object indicates the MONITORED Port Index that the Monitoring port monitors. For DXC: The valid port number depends on the IO slot no., the installed card type and the port type: external, internal. * The external ports will according to the convention (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The internal ports will be according to the convention (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 . * 100 - no port monitored For Optimux-T3: The valid channels are: 0 = no Ch monitored 1..21 or 1..28 (=CH1..CH21 or CH1..CH28) according to product's configuration.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtMonitoredTSs 1.3.6.1.4.1.164.3.3.3.1.6.1.6
This object indicates which TSs of the Monitored port, should be monitored. Each Bit of the Octet represents a TS: 31 ......0 MSB LSB Bit 0 will not be used. If the bit value is '1' - this TS should be monitored. For a T1 port, the valid raised bits ('1') are: 1..24. For an E1 port, the valid raised bits ('1') are: 1..31. Default: all bits='0' Agents that do not support this feature will send SIZE 0. This object can be Set as described only if prtMonitoringEnable=enabled.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..4)  

prtCfgParam 1.3.6.1.4.1.164.3.3.3.1.7
OBJECT IDENTIFIER    

prtCfgParamTable 1.3.6.1.4.1.164.3.3.3.1.7.1
The write operation into the Table Objects is valid only to the TmpCnfg entry. KMUX parameters are for the cards: KMBE/New, KVF.6 family.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtCfgParamEntry

prtCfgParamEntry 1.3.6.1.4.1.164.3.3.3.1.7.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtCfgParamEntry  

prtCfgParamCnfgIdx 1.3.6.1.4.1.164.3.3.3.1.7.1.1.1
This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

prtCfgParamIdx 1.3.6.1.4.1.164.3.3.3.1.7.1.1.2
A unique identifier of the port (within the card when applicable). - For KM-2100: Slot*100+Ch external ports: Ch=1..10 internal ports (sub-channels): Ch=11..20. - For FCD-T1/E1(L): MAIN=111, SUB=113, CH1=122, CH2=124. - For other devices, see specific device's spec.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtCfgParamSlt 1.3.6.1.4.1.164.3.3.3.1.7.1.1.3
This attribute indicates a unique number to identify the slot where the card is inserted in. In the 2104 Unit the entries kmxIO5(111)..kmxIO12(118) are not valid. notApplicable(255) - for products that do not have Slots.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), kmxIO1(107), kmxIO2(108), kmxIO3(109), kmxIO4(110), kmxIO5(111), kmxIO6(112), kmxIO7(113), kmxIO8(114), kmxIO9(115), kmxIO10(116), kmxIO11(117), kmxIO12(118), notApplicable(255)  

prtCfgParamOperatedMl 1.3.6.1.4.1.164.3.3.3.1.7.1.1.4
The main link for this channel. The field is relevant only for ML modes of Dual, Priority Bumping and Switched Backup.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), kmxMlA(103), kmxMlB(104)  

prtCfgParamMlAtoMlBPrio 1.3.6.1.4.1.164.3.3.3.1.7.1.1.5
ML-A to ML-B Priority. The field is relevant only for ML modes of Priority Bumping and Switched Backup.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), low(2), high(3)  

prtCfgParamMlBtoMlAPrio 1.3.6.1.4.1.164.3.3.3.1.7.1.1.6
ML-B to ML-A Priority. The field is relevant only for ML modes of Priority Bumping.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), low(2), high(3)  

prtCfgParamInbandLoopDetection 1.3.6.1.4.1.164.3.3.3.1.7.1.1.7
Inband Loop Detection. The field is relevant for FCD-T1/E1(L) ports.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

prtCfgParamInbandLoopPatternCfg 1.3.6.1.4.1.164.3.3.3.1.7.1.1.8
This object indicates if Inband Loop polynomial pattern will be according to RDL Loop (the standard) or User Configurated according to prtCfgParamInbandLoopActPattern and prtCfgParamInbandLoopDeactPattern.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), rdlLoop(2), userConfig(3)  

prtCfgParamInbandLoopActPattern 1.3.6.1.4.1.164.3.3.3.1.7.1.1.9
This object is a binary string of up to 8 bits. Though the syntax allows for any ASCII characters, for this object only '0' or '1' characters are valid. The string determines coefficients of the polynomial pattern sent to the port in order to Activate the Inband Loop. This object is relevant only when prtCfgParamInbandLoopPatternCfg=userConfig.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

prtCfgParamInbandLoopDeactPattern 1.3.6.1.4.1.164.3.3.3.1.7.1.1.10
This object is a binary string of up to 8 bits. Though the syntax allows for any ASCII characters, for this object only '0' or '1' characters are valid. The string determines coefficients of the polynomial pattern sent to the port in order to Deactivate the Inband Loop. This object is relevant only when prtCfgParamInbandLoopPatternCfg=userConfig.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

prtT1E1StatTable 1.3.6.1.4.1.164.3.3.3.2.1
T1/E1 port statistics table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtT1E1StatEntry

prtT1E1StatEntry 1.3.6.1.4.1.164.3.3.3.2.1.1
An entry in the T1/E1 port statistics table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtT1E1StatEntry  

prtT1E1SPrtIdx 1.3.6.1.4.1.164.3.3.3.2.1.1.1
This attribute indicates a unique port number. The same numbering as for prtGenPrtIdx. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside. * The outside ports will be the T1/E1 cards ports. The convention used will be (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 .
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtT1E1SSlt 1.3.6.1.4.1.164.3.3.3.2.1.1.2
This attribute indicates a unique number to identify the slot where the card is inserted in. When the unit is stand-alone, this object is not applicable and 255 will be used.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER clA(3), clB(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), standAlone(255)  

prtT1E1OosCount 1.3.6.1.4.1.164.3.3.3.2.1.1.3
This object is applicable only for an E1 active port. It provides the number of red alarm events since the last count clearing.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtT1E1BpvLastMin 1.3.6.1.4.1.164.3.3.3.2.1.1.4
This object is applicable only for an E1 active port. It provides the number of BPV (BiPolar Violation) events detected during the last minute.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtT1E1BpvMax 1.3.6.1.4.1.164.3.3.3.2.1.1.5
This object is applicable only for an E1 active port. It provides the maximal number of BPV (BiPolar Violation) events (per minute), detected during the worst minute.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

prtT1E1CnfgTable 1.3.6.1.4.1.164.3.3.3.2.2
T1/E1 port configuration table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtT1E1CnfgEntry

prtT1E1CnfgEntry 1.3.6.1.4.1.164.3.3.3.2.2.1
An entry in the T1/E1 port configuration table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtT1E1CnfgEntry  

prtT1E1CnfgIdx 1.3.6.1.4.1.164.3.3.3.2.2.1.1
This attribute indicates the Idx of the Config being accessed. Idx of 255 relates to the Temporary (Scratch) Config.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

prtT1E1PrtIdx 1.3.6.1.4.1.164.3.3.3.2.2.1.2
This attribute indicates a unique port number. The same numbering as for prtGenPrtIdx. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside. In the DXC : - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card in odd or even numbers, as follows: * For the outside/external ports, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The inside/internal ports, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 . In the Kilomux, the port index is calculated as follows: 100*Slot+Ch. The external Ch numbers are 1..10, and the internal Ch numbers are 11..20.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtT1E1Slt 1.3.6.1.4.1.164.3.3.3.2.2.1.3
This attribute indicates a unique number to identify the slot where the card is inserted in. When the unit is stand-alone, this object is not applicable and 255 will be used.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER clA(3), clB(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), kmxMlA(103), kmxMlB(104), kmxOpt(106), kmxIO1(107), kmxIO2(108), kmxIO3(109), kmxIO4(110), kmxIO5(111), kmxIO6(112), kmxIO7(113), kmxIO8(114), kmxIO9(115), kmxIO10(116), kmxIO11(117), kmxIO12(118), standAlone(255)  

prtT1E1LineType 1.3.6.1.4.1.164.3.3.3.2.2.1.4
This variable indicates the variety of T1/E1 Line implementing this circuit. The type of circuit affects the number of bits per second that the circuit can reasonably carry, as well as the interpretation of the usage and error statistics. The values, in sequence, describe: TITLE: SPECIFICATION: esf Extended SuperFrame DS1 d4 AT&T D4 format DS1 - SF e1 CCITT Recommendation G.704 (Table 4a) - G732N e1Crc CCITT Recommendation G.704 (Table 4b) - G732N with CRC e1MF G.704 (Table 4a) with TS16 multiframing enabled - G732S e1CrcMF G.704 (Table 4b) with TS16 multiframing enabled - G732S with CRC unframed T1 - applicable values: (1),(2),(3),(8) E1 - applicable values: (1),(4),(5),(6),(7),(8)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER other(1), esf(2), d4(3), e1(4), e1Crc(5), e1MF(6), e1CrcMF(7), unframed(8)  

prtT1E1LineCode 1.3.6.1.4.1.164.3.3.3.2.2.1.5
This variable describes the variety of Zero Code Suppression used on the link, which in turn affects a number of its characteristics. jbzs=b7zs refers the Jammed Bit Zero Suppres- sion, in which the AT&T specification of at least one pulse every 8 bit periods is literal- ly implemented by forcing a pulse in bit 8 of each channel. Thus, only seven bits per chan- nel, or 1.344 Mbps, is available for data (used for T1). b8zs refers to the use of a specified pattern of normal bits and bipolar violations which are used to replace a sequence of eight zero bits (used for T1). ANSI Clear Channels may use zbtsi, or Zero Byte Time Slot Interchange. E1 links, with or without CRC, use hdb3 or ami (= TRAN). amI (=TRAN) refers to a mode wherein no zero code suppression is present and the line encoding does not solve the problem directly. In this application, the higher layer must provide data which meets or exceeds the pulse density re- quirements, such as inverting HDLC data.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER jbzs(1), b8zs(2), hdb3(3), zbtsi(4), ami(5), other(6)  

prtT1E1SignalMode 1.3.6.1.4.1.164.3.3.3.2.2.1.6
'none' indicates that no bits are reserved for signaling on this channel. 'robbedBit' indicates that T1 Robbed Bit Signaling is in use. 'bitOriented' indicates that E1 Channel Associated Signaling (CAS) is in use. 'messageOriented' indicates that Common Channel Signaling (CCS) is in use either on channel 16 of an E1 link or channel 24 of a T1.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), robbedBit(2), bitOriented(3), messageOriented(4)  

prtT1E1Fdl 1.3.6.1.4.1.164.3.3.3.2.2.1.7
This bitmap describes the use of the facili- ties data link, and is the sum of the capabili- ties: 'other' indicates that a protocol other than one following is used. 'ansi-T1-403' refers to the FDL exchange recommended by ANSI. 'att-54016' refers to ESF FDL exchanges. 'fdl-none' indicates that the device does not use the FDL. 'transFdl' indicates transition between two ports of the same card.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER other(1), ansi-T1-403(2), att-54016(4), fdl-none(8), transFdl(16)  

prtT1E1FdlMode 1.3.6.1.4.1.164.3.3.3.2.2.1.8
Fdl Mode of the T1 selected port. notApplicable - will be used for an E1 port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER other(1), user(2), carrier(3), notApplicable(255)  

prtT1E1Sync 1.3.6.1.4.1.164.3.3.3.2.2.1.9
This object enables returning to normal operation, after the end of a main/sub link red alarm event, in reduced time. 'tr62411' - complies with AT&T TR-62411 (after 10 seconds). Applicable for both T1 and E1 interfaces. 'ccitt' - complies with CCITT standard. Applicable only for E1 interfaces. 'fast' - after 1 second.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER other(1), tr62411(2), ccitt(3), fast(4)  

prtT1E1CGA 1.3.6.1.4.1.164.3.3.3.2.2.1.10
This object selects the method used to signal the CGA state to the other end, through the main/sub link. 'none' - non-transparent mode. When one of the links (main/sub) will be in Out Of Service state, both 'Data/Voice Oos' and 'Oos Signal' will be transmitted to the other end. 'trans' - when one of the links (main/sub) will be in Out Of Service state, 'Data/Voice Oos' will be transmitted to the other end. 'full' - fully-transparent mode. When one of the links (main/sub) will be in Out Of Service state, neither 'Data/Voice Oos' nor 'Oos Signal' will be transmitted to the other end.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), trans(2), full(3)  

prtT1E1IdleCode 1.3.6.1.4.1.164.3.3.3.2.2.1.11
This object selects the code transmitted to fill idle (unused) time slots in the main link frame. Valid range: (0 - FF HEX) .
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..4)  

prtT1E1OosSignal 1.3.6.1.4.1.164.3.3.3.2.2.1.12
'idle' = '0' = on-hook, idle state 'busy' = '1' = off-hook, busy state 'forcedIdle' = SP = both A and B signaling bits are forced to '0' during out-of-service periods. 'forcedBusy' = MK = both A and B signaling bits are forced to '1' during out-of-service periods. 'busyIdle' = MK_SP = A and B bits are forced to '1' for 2.5 seconds; then they are switched to '0' until out-of-service condition disappears. 'idleBusy' = SP_MK = A and B bits are forced to '0' for 2.5 seconds; then they are switched to '1' until out-of-service condition disappears. - for T1: '0'=0 ; '1'=1 - for E1: '0'=1 ; '1'=0
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notsupported(2), forcedIdle(3), forcedBusy(4), busyIdle(5), idleBusy(6)  

prtT1E1VoiceOos 1.3.6.1.4.1.164.3.3.3.2.2.1.13
Voice Out-Of-Service code. Valid range: (0 - FF HEX). For agents that do not support this feature, the value will always be 0.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..4)  

prtT1E1DataOos 1.3.6.1.4.1.164.3.3.3.2.2.1.14
Data Out-Of-Service code. Valid range: (0 - FF HEX). For agents that do not support this feature, the value will always be 0.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..4)  

prtT1E1LineLengthMask 1.3.6.1.4.1.164.3.3.3.2.2.1.15
This attribute is the line length mask parameter used only for T1/DSU interfaces. len400p533ft=length range: 400ft to 533ft 'fcc68' - provides compliance with the FCC 68.308 Option A output pulse mask.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), len0p133ft(2), len134p266ft(3), len267p399ft(4), len400p533ft(5), len534p655ft(6), fcc68(7)  

prtT1E1TxGainMask 1.3.6.1.4.1.164.3.3.3.2.2.1.16
This attribute is the tx gain mask parameter (dB), used only for T1/CSU interfaces.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), txGain0db(2), txGain7dot5db(3), txGain15db(4), txGain22dot5db(5)  

prtT1E1InbandMng 1.3.6.1.4.1.164.3.3.3.2.2.1.17
A unique number to identify an Inband management over the link. internal - supported by KM-2100 only. It means that the management is internal to the frame. It takes part of the ML Frame bits (instead of data).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), fdlOrTs0(3), dedicatedTs(4), dedicatedPpp(5), dedicatedFr(6), internal(7)  

prtT1E1InbandMngRate 1.3.6.1.4.1.164.3.3.3.2.2.1.18
A unique number to identify the rate of the Inband management. It is required only for E1 links and is applicable only when prtExT1E1InbandMng selected is FdlOrTs0 or dedicatedTs.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), r4k(2), r8k(3), r12k(4), r16k(5), r32k(6), r64k(7), r20k(8)  

prtT1E1DedicatedTs 1.3.6.1.4.1.164.3.3.3.2.2.1.19
The value is differently determined for different products. There are two methods: 1) A unique number to identify Dedicated TS of the T1/E1 port. It is applicable only when prtExT1E1InbandMng selected is dedicatedTs. 1..24 - Dedicated TS of T1 1..31 - Dedicated TS of E1 255 - notApplicable (for agents that do not support this feature) Other values are invalid. 2) For FCD-STM, up to five TSs may be dedicated to management. This object value is the Sum (sigma) of 2**n, where n =TS-1 e.g. Time slots 3,5,7,9,11 are dedicated to management: 2** 2 +2** 4 +2** 6 +2** 8 +2**10 = 4+16+64+256+1024=1364 User should consult the product specification, to find out the method employed.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtT1E1InbandMngRoutProt 1.3.6.1.4.1.164.3.3.3.2.2.1.20
Inband Mng Routing Protocol of the port. When prtT1E1InbandMng is 'dedicatedPpp'-'proprietary' and 'rip2' are applicable. For other values - only 'proprietary' is applicable. For FCD-M and FCD-A: When prtT1E1InbandMng is 'dedicatedPpp' or 'dedicatedFr': 'None', 'proprietary' and 'rip2' are applicable. When prtT1E1InbandMng is 'fdlOrTS0' or 'dedicatedTs': 'None' and 'proprietary' are applicable. When prtT1E1InbandMng is 'off': 'None' is applicable.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), none(2), proprietary(3), rip2(4)  

prtT1E1LinkMode 1.3.6.1.4.1.164.3.3.3.2.2.1.21
regular - TSs are connected by user via TS Assignment only transparent - when a port with this Link Mode is connected to an internal T1/E1 port of a T3/E3 card, TS0, TS16 and Fbit are transparently transferred to the E3/T3 stream.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), regular(2), transparent(3)  

prtT1E1Multiplier 1.3.6.1.4.1.164.3.3.3.2.2.1.22
The data rate of each TS. The multiplier values can be 56 kbps or 64 kbps. For T1 only.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), br56(2), br64(3)  

prtT1E1RxGain 1.3.6.1.4.1.164.3.3.3.2.2.1.23
This attribute is the rx volume (dB).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), rxGain12dB(2), rxGain30dB(3), rxGain36dB(4), shortHaul(5), longHaul(6), rxGain20dB(7)  

prtT1E1RAI 1.3.6.1.4.1.164.3.3.3.2.2.1.24
Remote Alarm Signal
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), off(2), on(3)  

prtT1E1LineMode 1.3.6.1.4.1.164.3.3.3.2.2.1.25
Interface type of the port. For T1 - csu, dsu are the valid values For E1 - dsu, ltu are the valid values
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), csu(2), dsu(3), ltu(4)  

prtT1E1TS0SaBits 1.3.6.1.4.1.164.3.3.3.2.2.1.26
This object is applicable only for E1 ports. For T1, string size will be 0. For E1, it enables user to select the use of TS0 Sa Bits 4..8, by 3 octets: The order (in hexa display): free Sa-Bit-4 Sa-Bit-5 Sa-Bit-6 Sa-Bit-7 Sa-Bit-8 |___________| |________________| |________________| MSByte LSByte Each Sa Bit will be represented by a nibble, having the following meaning: 0000 = zero 0001 = one 0010 = management 0011 = transparent the rest are reserved for future use.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

prtT1E1ConnectedTS 1.3.6.1.4.1.164.3.3.3.2.2.1.27
This parameter indicates if there is any connected TS for this interface.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

prtT1E1Ts0SaBit 1.3.6.1.4.1.164.3.3.3.2.2.1.28
This parameter indicates whether to send TS 0, or not. noMng= TS 0 is looped, therefore not sent. mng= TS 0 isn't looped, therefore it is sent.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), noMng(2), mng(3)  

prtT1E1SameFeCnfg 1.3.6.1.4.1.164.3.3.3.2.2.1.29
This parameter indicates whether the same E1 configuration parameters and TS assignment are set both to the local and remote device. Read-Write access is applicable only in G732N framed mode. For G732S and UNFRAMED this parameter is set by agent to YES and is Read Only. In Case of conflict during power-up between the central and remote, the value set by the central unit is the valid one.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

prtT1E1RemCrc4 1.3.6.1.4.1.164.3.3.3.2.2.1.30
This object indicates whether the E1 of the Remote device connected to this E1 port, will have CRC-4 or not.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

prtT1E1MaxTSs 1.3.6.1.4.1.164.3.3.3.2.2.1.31
This object is applicable only for DXC D4T1, D4E1, D8T1, D8E1 external ports and D8GSL internal E1 ports. It is relevant only when sysCIntTsAllocMode=static(2). 255=not applicable If prtT1E1LineType=unframed(8), the value of this object must be 32. Else, the valid values are 0..31.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtT1E1EocTsConfig 1.3.6.1.4.1.164.3.3.3.2.2.1.32
This object indicates whether the use of EOC for TS Configuration is enabled or not.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

prtT1E1Role 1.3.6.1.4.1.164.3.3.3.2.2.1.33
This object indicates whether this port behaves as SUB or Main link.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), sub(2), main(3)  

prtT1E1PppEchoFailDetection 1.3.6.1.4.1.164.3.3.3.2.2.1.34
This object indicates whether the PPP Echo is taken into account for its Fail Detection. This object is relevant when Inband Mng between devices is Dedicated TS PPP. Default=Disable. Enable - will be selected mainly when a T1/E1 Ring exists and between 2 adjacent Ring devices there is another device or Net, that causes these Ring devices not to sense that the PPP connection between them is lost. In this case, Echo Request should be initiated by the port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

prtT1E1FdlMsgTable 1.3.6.1.4.1.164.3.3.3.2.3
This table is applicable for a T1 interface with 'esf' LineType or E1 interface, when CRC is enabled (LineType).
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtT1E1FdlMsgEntry

prtT1E1FdlMsgEntry 1.3.6.1.4.1.164.3.3.3.2.3.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtT1E1FdlMsgEntry  

prtT1E1FdlMsgPrtIdx 1.3.6.1.4.1.164.3.3.3.2.3.1.1
This attribute indicates a unique port number. The same numbering as for prtGenPrtIdx. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside. * The outside ports will be the T1/E1 cards ports. The convention used will be (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 .
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtT1E1FdlMsgFdlType 1.3.6.1.4.1.164.3.3.3.2.3.1.2
The Fdl type reference of the Fdl message.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER send(1), receive(2)  

prtT1E1FdlMsgSlt 1.3.6.1.4.1.164.3.3.3.2.3.1.3
This attribute indicates a unique number to identify the slot where the card is inserted in. When the unit is stand-alone, this object is not applicable and 255 will be used.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), standAlone(255)  

prtT1E1FdlMsg 1.3.6.1.4.1.164.3.3.3.2.3.1.4
FDL message.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

prtHSParamTable 1.3.6.1.4.1.164.3.3.3.3.1
A table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtHSParamEntry

prtHSParamEntry 1.3.6.1.4.1.164.3.3.3.3.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtHSParamEntry  

prtHSCnfgIdx 1.3.6.1.4.1.164.3.3.3.3.1.1.1
This attribute indicates the Idx of the Config being accessed. Idx of 255 relates to the Temporary (Scratch) Config.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

prtHSPrtIdx 1.3.6.1.4.1.164.3.3.3.3.1.1.2
This attribute indicates a unique number to identify a port. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside, SP. * The inside ports will be the HS cards ports. The convention used will be (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 .
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtHSSlt 1.3.6.1.4.1.164.3.3.3.3.1.1.3
This attribute indicates a unique number to identify the slot where the card is inserted in. When the unit is stand-alone, this object is not applicable and 255 will be used.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), standAlone(255)  

prtHSRate 1.3.6.1.4.1.164.3.3.3.3.1.1.4
This object indicates the port rate (speed). auto - rate is selected automatically by system.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER r0x56eq0Kbps(1), r1x56eq56Kbps(2), r2x56eq112Kbps(3), r3x56eq168Kbps(4), r4x56eq224Kbps(5), r5x56eq280Kbps(6), r6x56eq336Kbps(7), r7x56eq392Kbps(8), r8x56eq448Kbps(9), r9x56eq504Kbps(10), r10x56eq560Kbps(11), r11x56eq616Kbps(12), r12x56eq672Kbps(13), r13x56eq728Kbps(14), r14x56eq784Kbps(15), r15x56eq840Kbps(16), r16x56eq896Kbps(17), r17x56eq952Kbps(18), r18x56eq1008Kbps(19), r19x56eq1064Kbps(20), r20x56eq1120Kbps(21), r21x56eq1176Kbps(22), r22x56eq1232Kbps(23), r23x56eq1288Kbps(24), r24x56eq1344Kbps(25), r25x56eq1400Kbps(26), r26x56eq1456Kbps(27), r27x56eq1512Kbps(28), r28x56eq1568Kbps(29), r29x56eq1624Kbps(30), r30x56eq1680Kbps(31), r31x56eq1736Kbps(32), r0x64eq0Kbps(33), r1x64eq64Kbps(34), r2x64eq128Kbps(35), r3x64eq192Kbps(36), r4x64eq256Kbps(37), r5x64eq320Kbps(38), r6x64eq384Kbps(39), r7x64eq448Kbps(40), r8x64eq512Kbps(41), r9x64eq576Kbps(42), r10x64eq640Kbps(43), r11x64eq704Kbps(44), r12x64eq768Kbps(45), r13x64eq832Kbps(46), r14x64eq896Kbps(47), r15x64eq960Kbps(48), r16x64eq1024Kbps(49), r17x64eq1088Kbps(50), r18x64eq1152Kbps(51), r19x64eq1216Kbps(52), r20x64eq1280Kbps(53), r21x64eq1344Kbps(54), r22x64eq1408Kbps(55), r23x64eq1472Kbps(56), r24x64eq1536Kbps(57), r25x64eq1600Kbps(58), r26x64eq1664Kbps(59), r27x64eq1728Kbps(60), r28x64eq1792Kbps(61), r29x64eq1856Kbps(62), r30x64eq1920Kbps(63), r31x64eq1984Kbps(64), r32x64eq2048Kbps(65), r32x56eq1792Kbps(66), r64x64eq4096Kbps(67), auto(200)  

prtHSFifoSize 1.3.6.1.4.1.164.3.3.3.3.1.1.5
This object selects the size of the user data channel buffer FIFO used in the DTE2 mode. In the other modes, buffer size is automatically set by the DACS agent. Buffer FIFO size in bits, corresponds to FIFO lengths of +/-16, +/-30, +/-52, +/-72 bits.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER auto(1), b32bit(2), b60bit(3), b104bit(4), b144bit(5), notApplicable(255)  

prtHSClkMode 1.3.6.1.4.1.164.3.3.3.3.1.1.6
Clock Mode of the user data channel. dce - DACS operates as a DCE and provides transmit and receive clocks to the synchronous user DTE. dte1- DACS supplies the receive clock to the user equipment and accepts the user transmit clock. dte2- DACS requires transmit and receive clocks from the user equipment.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER dce(1), dte1(2), dte2(3), notApplicable(255)  

prtHSCTS 1.3.6.1.4.1.164.3.3.3.3.1.1.7
Selection of CTS line state in the user data channel. on - CTS continuously ON. rts - CTS line follows the RTS line.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER on(1), rts(2), notApplicable(255)  

prtHSRtsState 1.3.6.1.4.1.164.3.3.3.3.1.1.8
RTS state of the port.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(2), on(3), notApplicable(255)  

prtHSInbandLoopback 1.3.6.1.4.1.164.3.3.3.3.1.1.9
This object indicates if Inband Loopback from the Network should be enabled or disabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), disabled(2), enabled(3)  

prtHSInbandLoopPatternCfg 1.3.6.1.4.1.164.3.3.3.3.1.1.10
This object indicates if Inband Loop polynomial pattern will be according to RDL Loop (the standard) or User Configurated according to prtHSActivatePolyPattern and prtHSDeactivatePolyPattern.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), rdlLoop(2), userConfig(3)  

prtHSInbandLoopActPattern 1.3.6.1.4.1.164.3.3.3.3.1.1.11
This object is a binary string of up to 8 bits. Though the syntax allows for any ASCII characters, for this object only '0' or '1' characters are valid. The string determines coefficients of the polynomial pattern sent to the port in order to Activate the Inband Loop. This object is relevant only when prtHSInbandLoopPatternCfg=userConfig.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

prtHSInbandLoopDeactPattern 1.3.6.1.4.1.164.3.3.3.3.1.1.12
This object is a binary string of up to 8 bits. Though the syntax allows for any ASCII characters, for this object only '0' or '1' characters are valid. The string determines coefficients of the polynomial pattern sent to the port in order to Deactivate the Inband Loop. This object is relevant only when prtHSInbandLoopPatternCfg=userConfig.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

prtHSDCD 1.3.6.1.4.1.164.3.3.3.3.1.1.13
Selection of DCD line state in the user data channel. linkOK - DCD line is ON only when active link is OK. on - DCD continuously ON.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), linkOK(2), on(3)  

prtHSClkPolarity 1.3.6.1.4.1.164.3.3.3.3.1.1.14
This object indicates the clock polarity.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), normal(2), invert(3)  

prtHSInterfaceType 1.3.6.1.4.1.164.3.3.3.3.1.1.15
This object indicates the selected electrical interface type.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), rs530(2), v35(3), rs422(4), x21(5), v24(6), rs530a(7), rs232(8), rs449(9)  

prtHSUnframed 1.3.6.1.4.1.164.3.3.3.3.1.1.16
Unframed line for HS ports. yes - means that all TSs must be transferred, including TS0. In this case, prtHSRate must be r31x56eq1736Kbps OR r31x64eq1984Kbps.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

prtHSBertTable 1.3.6.1.4.1.164.3.3.3.3.2
A table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtHSBertEntry

prtHSBertEntry 1.3.6.1.4.1.164.3.3.3.3.2.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtHSBertEntry  

prtHSBertPrtIdx 1.3.6.1.4.1.164.3.3.3.3.2.1.1
This attribute indicates a unique number to identify a port. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside, SP. * The inside ports will be the HS cards ports. The convention used will be (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 .
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtHSBertSlt 1.3.6.1.4.1.164.3.3.3.3.2.1.2
This attribute indicates a unique number to identify the slot where the card is inserted in. When the unit is stand-alone, this object is not applicable and 255 will be used.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), standAlone(255)  

prtHSBertCountClr 1.3.6.1.4.1.164.3.3.3.3.2.1.3
Setting this object (to on) initiate bert counter clear operation. Valid only when bert test is active on the specific port. (Every time a new bert test starts, the counter is automatically cleared; this command enables clearing the counter while the test is running).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

prtHSBertTestResult 1.3.6.1.4.1.164.3.3.3.3.2.1.4
This object indicates the number of Bit Error Rate indicated during the BERT test. Active only when bert test is running on the selected port.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtSpCnfgTable 1.3.6.1.4.1.164.3.3.3.4.1
A table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtSpCnfgEntry

prtSpCnfgEntry 1.3.6.1.4.1.164.3.3.3.4.1.1
All the entries at this table are identical(have the same value) at all the configurations(1..255) except at the TmpCnfg. - For products supporting more than one configuration, the write operation into the Table Objects is valid only at the TmpCnfg entry. - For products that do not support configurations, the write operation into the Table Objects will be to prtSpCnfgIdx=1.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtSpCnfgEntry  

prtSpCnfgIdx 1.3.6.1.4.1.164.3.3.3.4.1.1.1
This attribute indicates the Idx of the Cnfg(1..255) being accessed. Idx of 255 relates to the TmpCnfg.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

prtSpPrtIdx 1.3.6.1.4.1.164.3.3.3.4.1.1.2
This attribute indicates a unique port number of the SPor DP port. For DXC, it is the port in the active DCL card: - SP = 1 - NP ; DP = 2 For Kilomux, the port index is calculated as follows: 100*Slot+Ch. For FCD, PRBi, the SP port index=1. For Optimux-T3, the SP port index=71.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtSpUsage 1.3.6.1.4.1.164.3.3.3.4.1.1.3
This attribute indicates what is the usage of the port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), noUse(2), nmsSlip(3), nmsPpp(4), muxSlip(5), muxPpp(6), terminal(7), dialOut(8)  

prtSpRate 1.3.6.1.4.1.164.3.3.3.4.1.1.4
This attribute indicates the operation rate (speed) of the port. auto - automatic rate selection, by the agent.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER auto(1), s300bps(2), s1200bps(3), s2400bps(4), s4800bps(5), s9600bps(6), s19200bps(7), s38400bps(8), s57600bps(9), s115200bps(10)  

prtSpDataBits 1.3.6.1.4.1.164.3.3.3.4.1.1.5
This attribute indicates the number of data bits in async frame
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER dataBits7(1), dataBits8(2)  

prtSpParity 1.3.6.1.4.1.164.3.3.3.4.1.1.6
This attribute indicates the parity mode in async frame
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), odd(2), even(3)  

prtSpCallOutMode 1.3.6.1.4.1.164.3.3.3.4.1.1.7
This attribute indicates the call-out mode. For DXC - this object is applicable only for the DP port (2).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), none(2), all(3), major(4)  

prtSpInterface 1.3.6.1.4.1.164.3.3.3.4.1.1.8
This attribute indicates the supervisory port interface. dce - the DACS appears as a DCE for the port. dte - the DACS operates as a DTE, for connection via modem, for the port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER dce(1), dte(2)  

prtSpCTS 1.3.6.1.4.1.164.3.3.3.4.1.1.9
CTS line state. This object is applicable only for port (1) = SP
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), on(2), rts(3)  

prtSpDcdDelay 1.3.6.1.4.1.164.3.3.3.4.1.1.10
DCD delay in msec. d10 = delay of 10msec. This object is applicable only for port (1) = SP
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), d0(2), d10(3), d50(4), d100(5), d200(6), d300(7)  

prtSpDsr 1.3.6.1.4.1.164.3.3.3.4.1.1.11
DSR line state. This object is applicable only for port (1) = SP
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), on(2), dtr(3)  

prtSpNoOfRetries 1.3.6.1.4.1.164.3.3.3.4.1.1.12
For DXC - this object is applicable only for port (2) = DP. The number of dialing retries requested. Default = 0
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..8  

prtSpWaitForConnect 1.3.6.1.4.1.164.3.3.3.4.1.1.13
For DXC - this object is applicable only for port (2) = DP. Waiting time for connect, in seconds. Default = 30 sec.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), t30sec(2), t45sec(3), t60sec(4)  

prtSpDialMode 1.3.6.1.4.1.164.3.3.3.4.1.1.14
For DXC - this object is applicable only for port (2) = DP. Dialing mode. Default=tone
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), tone(2), pulse(3)  

prtSpAltNumMode 1.3.6.1.4.1.164.3.3.3.4.1.1.15
For DXC - this object is applicable only for port (2) = DP. It determines wether to use the alternate number or not. Default = no.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtSpPrimaryNum 1.3.6.1.4.1.164.3.3.3.4.1.1.16
For DXC - this object is applicable only for port (2) = DP. It is the Primary dialing number.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..20)  

prtSpAltNum 1.3.6.1.4.1.164.3.3.3.4.1.1.17
For DXC - this object is applicable only for port (2) = DP. It is the Alternate dialing number. This number is applicable only if prtSpAltNumMode is 'yes'.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..20)  

prtSpRoutProtocol 1.3.6.1.4.1.164.3.3.3.4.1.1.18
This attribute indicates the routing protocol of the port. notApplicable - for DP.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), none(2), proprietary(3), rip2(4)  

prtSpCmd 1.3.6.1.4.1.164.3.3.3.4.1.1.19
SP Command. For LRS this parameter will be used for a Modem Command. Upon NMS's Get operation for devices that this parameter is notApplicable, agent will send NULL string.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(20)  

prtSpActCallOut 1.3.6.1.4.1.164.3.3.3.4.1.1.20
This object indicates when to Activate Call-Out. It is used by FCD-T1/E1. always - to activate call-out always. linkFail - to activate call-out only when Link of Inband Management fails.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), always(2), linkFail(3)  

prtSpAlrRelayMode 1.3.6.1.4.1.164.3.3.3.4.1.1.21
This attribute indicates the Alarm Relay Mode. notApplicable - for DP.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), normal(2), invert(3)  

prtSpStopBits 1.3.6.1.4.1.164.3.3.3.4.1.1.22
This attribute indicates number of stop bits in an async frame.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), stopBits1(2), stopBits1dot5(3), stopBits2(4)  

prtDimCnfgTable 1.3.6.1.4.1.164.3.3.3.5.1
A table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtDimCnfgEntry

prtDimCnfgEntry 1.3.6.1.4.1.164.3.3.3.5.1.1
The write operation into the Table Objects is valid only for the TmpCnfg entry (prtDimCnfgIdx=255).
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtDimCnfgEntry  

prtDimCnfgIdx 1.3.6.1.4.1.164.3.3.3.5.1.1.1
This attribute indicates the Idx of the Cnfg(1..255) being accessed. Idx of 255 relates to the TmpCnfg.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

prtDimIdx 1.3.6.1.4.1.164.3.3.3.5.1.1.2
This attribute indicates a unique port number of the DIM card. The convention used for DXC: (IO slot number+10)*10 + 1 Example: port1 of IO slot 11 will be: 211 .
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtDimTxMode 1.3.6.1.4.1.164.3.3.3.5.1.1.3
Tx mode. regularTx - the links are connected to a similar outfit on the other side. In this mode, if a link fails, the transmitted bandwidth is decreased accordingly. broadcast - the links are connected to MORE than one similar outfit on the other side. In this mode, if a link fails, the transmitted bandwidth is not affected
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER regularTx(2), broadcast(3)  

prtDimPolarity 1.3.6.1.4.1.164.3.3.3.5.1.1.4
Polarity.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER normalClk(2), inverted(3)  

prtDimClkMode 1.3.6.1.4.1.164.3.3.3.5.1.1.5
Clock Mode. smooth - a clock that is not 'pulsed'(has no 'gaps'). In this mode the DXC does NOT receive back the clock signal. extSmooth - same as 'smooth' but in this mode, the DXC receives back the clock signal.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER extDce(2), dce(3), smooth(4), extSmooth(5)  

prtDimMaxDelay 1.3.6.1.4.1.164.3.3.3.5.1.1.6
Max Delay permitted between the links, in msec.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER t16msec(2), t64msec(3)  

prtDimMng 1.3.6.1.4.1.164.3.3.3.5.1.1.7
Use of DIM port for management. disabled - no management on DIM ts1 - 1 bit of TS1 is used for management.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(2), ts1(3), dedicatedFr(4)  

prtDimMngRoutProt 1.3.6.1.4.1.164.3.3.3.5.1.1.8
Mng Routing Protocol of the port. none - when prtDimMng is 'disabled'.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), none(2), proprietary(3)  

prtDimDestTable 1.3.6.1.4.1.164.3.3.3.5.2
A table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtDimDestEntry

prtDimDestEntry 1.3.6.1.4.1.164.3.3.3.5.2.1
The write operation is valid only for the TmpCnfg entry (prtDimDestCnfgIdx=255).
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtDimDestEntry  

prtDestCnfgIdx 1.3.6.1.4.1.164.3.3.3.5.2.1.1
This attribute indicates the Idx of the Cnfg(1..255) being accessed. Idx of 255 relates to the TmpCnfg.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

prtDestDimIdx 1.3.6.1.4.1.164.3.3.3.5.2.1.2
This attribute indicates a unique port number of the DIM card. The convention used for DXC: (IO slot number+10) & 1 Example: port1 of IO slot 11 will be: 211 .
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtDestIdx 1.3.6.1.4.1.164.3.3.3.5.2.1.3
This attribute indicates a destination number of the DIM card.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..8  

prtDest 1.3.6.1.4.1.164.3.3.3.5.2.1.4
Destination port,(of a T1/E1 port), that is connected to the DIM card, for the specified Destination number. 0 = No destination port. Else: For external ports: (IO Slot+10) & 1 for port 1 (IO Slot+10) & 3 for port 2 Example: port2 of IO slot 12 will be: 223 . For internal ports : (IO Slot+10) & 2 for port 1 (IO Slot+10) & 4 for port 2 (IO Slot+10) & 6 for port 3 (IO Slot+10) & 8 for port 4, etc...
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtDestConnect 1.3.6.1.4.1.164.3.3.3.5.2.1.5
Connection Status of the specified destination number. For a specified destination port, it depends both on the status of the port and on the status of the far-end port. Since this is a RO object, same value will be received for all configurations.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

prtICnfgTable 1.3.6.1.4.1.164.3.3.3.6.1
A table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtICnfgEntry

prtICnfgEntry 1.3.6.1.4.1.164.3.3.3.6.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtICnfgEntry  

prtICnfgIdx 1.3.6.1.4.1.164.3.3.3.6.1.1.1
This attribute indicates the Idx of the Config being accessed. Idx of 255 relates to the Temporary (Scratch) Config.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

prtIIdx 1.3.6.1.4.1.164.3.3.3.6.1.1.2
This attribute indicates a unique number to identify a port. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside, SP. * The ISDN B1, B2, D channels will be inside ports. For port index, see product specification.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtIRate 1.3.6.1.4.1.164.3.3.3.6.1.1.3
This object indicates the port rate in bits. Each TS contains 8 bits. Thus, 1 bit is equivalent to 8Kbps rate.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), nc(2), r2bit(3), r4bit(4), r8bit(5)  

prtIConnect 1.3.6.1.4.1.164.3.3.3.6.1.1.4
D channel connection. no - disconnected yes - connected.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

prtHdslTable 1.3.6.1.4.1.164.3.3.3.7.1
HDSL port table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtHdslEntry

prtHdslEntry 1.3.6.1.4.1.164.3.3.3.7.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtHdslEntry  

prtHdslIdx 1.3.6.1.4.1.164.3.3.3.7.1.1.1
This attribute indicates a unique number to identify a port. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside. * The HDSL ports will be external. For port index, see product specification.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtHdslMode 1.3.6.1.4.1.164.3.3.3.7.1.1.2
This object indicates the HDSL mode.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), central(2), remote(3)  

prtHdslRptrType 1.3.6.1.4.1.164.3.3.3.7.1.1.3
The Repeater between Near and Far modem. none - no repeater exists between the modems hrpt - HRPT repeater exists between the modems.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), none(2), hrpt(3)  

prtHdslMaxRate 1.3.6.1.4.1.164.3.3.3.7.1.1.4
Maximum Rate of the xDSL Line, in Kbps units. This object can be Set only for a Central unit.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), r192(2), r256(3), r320(4), r384(5), r448(6), r512(7), r576(8), r640(9), r768(10), r896(11), r1024(12), r1152(13), r1280(14), r1536(15), r1920(16), r2048(17)  

prtHdslLinkType 1.3.6.1.4.1.164.3.3.3.7.1.1.5
The Link Type. msdsl2w - MSDSL 2 Wire hdsl2w - HDSL 2 Wire hdsl4w - HDSL 4 Wire gDsl - G.DSL
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), msdsl2w(2), hdsl2w(3), hdsl4w(4), gDsl(5)  

prtHdslCompSwVer 1.3.6.1.4.1.164.3.3.3.7.1.1.6
This object indicates the Software Version of the component (Piggyback card) supporting this interface.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

prtHdslCompHwVer 1.3.6.1.4.1.164.3.3.3.7.1.1.7
This object indicates the Hardware Version of the component (Piggyback card) supporting this interface.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

prtT3E3CnfgTable 1.3.6.1.4.1.164.3.3.3.8.1
T3/E3 port configuration table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtT3E3CnfgEntry

prtT3E3CnfgEntry 1.3.6.1.4.1.164.3.3.3.8.1.1
An entry in the T3/E3 port configuration table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtT3E3CnfgEntry  

prtT3E3CnfgIdx 1.3.6.1.4.1.164.3.3.3.8.1.1.1
This attribute indicates the Idx of the Config being accessed. Idx of 255 relates to the Temporary (Scratch) Config. For DXC, write operations can be performed only on the Temp Config. For products that do not support configurations, always 1 will be used.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

prtT3E3PrtIdx 1.3.6.1.4.1.164.3.3.3.8.1.1.2
This attribute indicates a unique port number. For DXC: The same numbering as for prtGenPrtIdx. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside. * The external ports convention used will be (for DXC): - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . For Optimux-T3: Link-A: 51 Link-B: 61 .
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

prtT3E3Slt 1.3.6.1.4.1.164.3.3.3.8.1.1.3
This attribute indicates a unique number to identify the slot where the card is inserted in. When the unit is stand-alone, this object is not applicable and 255 will be used.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER clA(3), clB(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), standAlone(255)  

prtT3E3LineLength 1.3.6.1.4.1.164.3.3.3.8.1.1.4
This object is the length of the ds3 line in feet. It provides information for line build out circuitry if it exists and can use this object to adjust the line build out. len0p450ft = 0 - 450 feet len451p900ft = 451 - 900 feet.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), len0p450ft(2), len451p900ft(3)  

prtT3E3InbandMng 1.3.6.1.4.1.164.3.3.3.8.1.1.5
A unique number to identify the Frame Type over the link. For Optimux-T3: only values (4), (7) are supported.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), off(2), cBit(3), cBitTxRxMng(4), cBitTx(5), cBitTxMng(6), m13(7), cdpv(8), nationalBit(9)  

prtT3E3AisFrame 1.3.6.1.4.1.164.3.3.3.8.1.1.6
This object is applicable only for Optimux-T3. It allows user to select whether the AIS sent will be framed or unframed.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), unframed(2), framed(3)  

prtT3E3TxClockSource 1.3.6.1.4.1.164.3.3.3.8.1.1.7
Tx Clock Source.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER external(1), internal(2), notApplicable(255)  

prtT3E3RoutProt 1.3.6.1.4.1.164.3.3.3.8.1.1.8
Routing Protocol of the port. This object is applicable only for T3 ports.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), none(2), proprietary(3), rip2(4)  

prtT3E3AisTransmit 1.3.6.1.4.1.164.3.3.3.8.1.1.9
Indicates if AIS signal will be transmitted over the tributary E3/DS3 upon failure.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

cmprTable 1.3.6.1.4.1.164.3.3.4.1
A table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CmprEntry

cmprEntry 1.3.6.1.4.1.164.3.3.4.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  CmprEntry  

cmprTypeIdx 1.3.6.1.4.1.164.3.3.4.1.1.1
This object indicates the Type of the Compressed data referred (which table, which level, etc). The type is a code according to a convention between agent and NMS.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cmprCnfgIdx 1.3.6.1.4.1.164.3.3.4.1.1.2
This object indicates the configuration number the Compressed information relates to.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cmprVersion 1.3.6.1.4.1.164.3.3.4.1.1.3
This object indicates the version of the internal format of the Compressed data (the version of the convention used).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cmprSltIdx 1.3.6.1.4.1.164.3.3.4.1.1.4
This attribute indicates a unique number of the slot position where the card is inserted. When the unit is stand-alone or this object is not applicable, 255 will be used.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER psA(1), psB(2), clA(3), clB(4), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), notApplicable(255)  

cmprPrtIdx 1.3.6.1.4.1.164.3.3.4.1.1.5
This object indicates a unique identifier of the port, the compressed information relates to. For DXC - according to the order in the card of cmprSltIdx: - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card in odd or even numbers, as follows: * For the outside/external ports, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The inside/internal ports, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 . For FCD: see product's specification. If the port number is irrelevant to this parameter (if it is a system/card level alarm) the value will be 9999.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

cmprObj 1.3.6.1.4.1.164.3.3.4.1.1.6
This object is the compressed information itself, according to a predefined format, both agent and NMS agreed about.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

mapLinkTable 1.3.6.1.4.1.164.3.3.4.2
A table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MapLinkEntry

mapLinkEntry 1.3.6.1.4.1.164.3.3.4.2.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  MapLinkEntry  

mapLinkIdx 1.3.6.1.4.1.164.3.3.4.2.1.1
A unique identifier of the link
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

mapLinkSlotIdx 1.3.6.1.4.1.164.3.3.4.2.1.2
This attribute indicates a unique slot position where the module is inserted.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), io13(17), io14(18), io15(19), standAlone(255)  

mapLinkPortIdx 1.3.6.1.4.1.164.3.3.4.2.1.3
This attribute indicates a unique port number. The valid port number depends on the IO slot no., the installed card type and the port type: outside, inside, SP. In the DXC : - first two digits will be: (IO slot number+10) - last one/two digits will be the port number within the card in odd or even numbers, as follows: * For the outside/external ports, in odd numbers: port1 = 1 port2 = 3 port3 = 5 etc... Example: port2 of IO slot 11 will be: 213 . * The inside/internal ports, in even numbers: port1 = 2 port2 = 4 port3 = 6 etc... Example: port2 of IO slot 11 will be: 214 .
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

mapLinkState 1.3.6.1.4.1.164.3.3.4.2.1.4
This attribute indicates the status of the link between the two muxes
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), down(2), up(3)  

alrGenTable 1.3.6.1.4.1.164.3.3.4.3
A table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AlrGenEntry

alrGenEntry 1.3.6.1.4.1.164.3.3.4.3.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AlrGenEntry  

alrGenCode 1.3.6.1.4.1.164.3.3.4.3.1.1
This object is a unique code number, identifying a certain alarm.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

alrGenDescription 1.3.6.1.4.1.164.3.3.4.3.1.2
This entry is a unique text description, of the alarm corresponding to the specified code.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

alrGenLevel 1.3.6.1.4.1.164.3.3.4.3.1.3
Alarm level.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), system(2), card(3), port(4)  

alrGenSlotType 1.3.6.1.4.1.164.3.3.4.3.1.4
Slot type that the alarm is relevant to. clAndIo - an alarm that is relevant for both CL and IO slots.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), ps(2), cl(3), io(4), clAndIo(5)  

alrGenSeverity 1.3.6.1.4.1.164.3.3.4.3.1.5
This object enables the user to select a severity for each alarm. The severity is set per alarm code (same for all slots/ports using this code).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), event(3), minor(4), major(5), warning(6), critical(7)  

alrGenDebounce 1.3.6.1.4.1.164.3.3.4.3.1.6
Debounce time for each alarm code, in seconds. The meaning is, that an alarm will be 'declared' as ON (or OFF), only after it was actually ON/OFF the Debouncing time selected by user. 0 = default debounce selection (each alarm has a default value). 250 = maximum value of seconds for debounce. 253 = mask = the alarm will Never be reported. 254 = default debounce selection (each alarm has a default value). 255 = not applicable
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..255  

alrGenDefSeverity 1.3.6.1.4.1.164.3.3.4.3.1.7
This object reports the default severity of each alarm. User can change the severity of the alarms defined by this default via the alrGenSeverity object.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), event(3), minor(4), major(5), warning(6), critical(7)  

dacsMuxEvents 1.3.6.1.4.1.164.3.3.0
The events for DACS MUX.
Status: current Access: read-only
OBJECT-IDENTITY    

sanityCheckTrap 1.3.6.1.4.1.164.3.3.0.1
This trap is sent after a data base download attempt. It returns the sanity result status and the configuration no.checked.
Status: current Access: read-only
NOTIFICATION-TYPE    

dacsMuxAlarmsTrap 1.3.6.1.4.1.164.3.3.0.2
This trap is sent when an alarm occurs.
Status: current Access: read-only
NOTIFICATION-TYPE    

mdlConnectTrap 1.3.6.1.4.1.164.3.3.0.3
This trap is sent when a card is removed.
Status: current Access: read-only
NOTIFICATION-TYPE    

sysAlrStatusTrap 1.3.6.1.4.1.164.3.3.0.4
This trap is sent upon any change in the value of any of the variables.
Status: current Access: read-only
NOTIFICATION-TYPE    

sysStatusChangedTrap 1.3.6.1.4.1.164.3.3.0.5
This trap is sent when Leds status is changed.
Status: current Access: read-only
NOTIFICATION-TYPE    

cnfgUpdateTrap 1.3.6.1.4.1.164.3.3.0.6
This trap is sent upon change of the active Configuration DB.
Status: current Access: read-only
NOTIFICATION-TYPE    

sysRedundancyStatusTrap 1.3.6.1.4.1.164.3.3.0.7
The trap is sent upon change in Redundancy Status.
Status: current Access: read-only
NOTIFICATION-TYPE    

sysRedundancyActiveCardTrap 1.3.6.1.4.1.164.3.3.0.8
The trap is sent upon change of Active Main/CL Card.
Status: current Access: read-only
NOTIFICATION-TYPE    

sysRedundancyActivePortTrap 1.3.6.1.4.1.164.3.3.0.9
The trap is sent upon change of Active Port of Redundancy Group.
Status: current Access: read-only
NOTIFICATION-TYPE    

services 1.3.6.1.4.1.164.6.3
OBJECT IDENTIFIER    

wfq 1.3.6.1.4.1.164.6.3.1
OBJECT IDENTIFIER    

wfqTable 2.1
This table allows user to define several WFQ tables per output port. WFQ supports flows with different bandwidth requirements by giving each queue a weight that assigns it a different percentage of output port bandwidth. When Weighted Fair Queuing is used, it is possible to precisely attribute bandwidth partitioning among the queues. When there is congestion, each class (queue) is not allowed to use more bandwidth than the amount allocated to it.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfqEntry

wfqEntry 2.1.1
An entry in the Weighted Fair Queueing table.
Status: current Access: not-accessible
OBJECT-TYPE    
  WfqEntry  

wfqCnfgIdx 2.1.1.1
This object indicates the Idx of the Agent Cnfg the following objects refer. 255=Temporary Cnfg (when relevant, Set is done only to this configuration). For Agents that support only one configuration, this object will be constant=1.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..255  

wfqPrtIdx 2.1.1.2
This object indicates a unique port or interface number, for which Weighted Fair Queueing table is applicable . For numbering, see product's spec. For some products, the numbering can equal ifIndex. Value of 255 (not applicable) refer to system level queue
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

wfqTblIdx 2.1.1.3
This object indicates which Weighted Fair Queueing (WFQ) Table is being used. There can be several tables. For FCD-155 User will select which one will be used for a virtual concatenation group.Valid values are 1,2
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

wfqQueueIdx 2.1.1.4
This object indicates a queue index. For FCD-155, valid queues are 1..3. The 4th queue is not in MIB. Its weight will be RO, Calculated according to the sum of the 3 first queues.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

wfqRowStatus 2.1.1.5
This object enables Creation/Deletion of rows in the WFQ table. For FCD-155, rows are not created nor destroyed by user.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

wfqWeightValue 2.1.1.6
This object indicates a relative weight value. User should make sure that the sum of values for all queues will not exceed 100% (sum should be BELOW 100% in order to leave some BW percentage for last queue) Note that when this attribute is being used, the wfqMinRateAbsolute attribute is NA.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..100  

wfqSchedulingMode 2.1.1.7
This object controls which scheduling mode is used: Weighted Fair Queuing (WFQ) scheme or priority Queue (Strict Priority).
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER disable(2), enable(3)  

wfqMinRateAbsolute 2.1.1.8
The minimum absolute rate, in kbps, that should be allocated to this queue. If the value is zero, then there is effectively no minimum rate guarantee. If the value is non-zero, then the servicing of this queue in at least this rate is assured. Note that when this attribute is being used, the wfqWeightValue attribute is NA.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

wfqMaxPacketSize 2.1.1.9
The size of the largest packet which can be received on this queue, specified in octets. Packets larger than this size will be discarded.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

dscpMapping 1.3.6.1.4.1.164.6.3.2
OBJECT IDENTIFIER    

dscpMappingTable 1.3.6.1.4.1.164.6.3.2.1
Mapping of DSCP value to a regenerated priority level.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DscpMappingEntry

dscpMappingEntry 1.3.6.1.4.1.164.6.3.2.1.1
An entry in dscpMappingTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  DscpMappingEntry  

dscpMappingCnfgIdx 1.3.6.1.4.1.164.6.3.2.1.1.1
This object indicates the Idx of the Agent Cnfg the following objects refer to. 255=Temporary Cnfg (when relevant, Set is done only to this configuration). For Agents that support only one configuration, this object will be constant=1. This object can be used to carry additional indexing (e.g port index) when needed.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..2147483647  

dscpMappingDscpIdx 1.3.6.1.4.1.164.6.3.2.1.1.2
DSCP value of the incoming IP packet
Status: current Access: not-accessible
OBJECT-TYPE    
  Dscp  

dscpMappingRegenPriority 1.3.6.1.4.1.164.6.3.2.1.1.3
The Regenerated Priority level the incoming DSCP value is mapped to. For FCD-155, valid values are 0,1,2,3
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

ifTeQos 1.3.6.1.4.1.164.6.3.3
OBJECT IDENTIFIER    

ifTeQosTable 1.3.6.1.4.1.164.6.3.3.1
The TE QOS Interface Table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IfTeQosEntry

ifTeQosEntry 1.3.6.1.4.1.164.6.3.3.1.1
An entry in the TE QOS Interface table.
Status: current Access: not-accessible
OBJECT-TYPE    
  IfTeQosEntry  

ifTeQosIdx1 1.3.6.1.4.1.164.6.3.3.1.1.1
This object indicates the 1st Index of the table.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

ifTeQosIdx2 1.3.6.1.4.1.164.6.3.3.1.1.2
This object indicates the 2nd Index of the table.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

ifTeQosIdx3 1.3.6.1.4.1.164.6.3.3.1.1.3
This object indicates the 3rd Index of the table.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

ifTeQosParam 1.3.6.1.4.1.164.6.3.3.1.1.4
This object is used for QOS attributes of the entry's entities.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

ifTeQosParam2 1.3.6.1.4.1.164.6.3.3.1.1.5
This object is used for 2nd group QOS attributes of the entry's entities.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

ifTeQosStatus 1.3.6.1.4.1.164.6.3.3.1.1.6
This object is used to create, activate and destroy entries of this table.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER active(1), createAndGo(4), destroy(6)  

portQos 1.3.6.1.4.1.164.6.3.4
OBJECT IDENTIFIER    

prtPriorityTable 1.3.6.1.4.1.164.6.3.4.1
A table - Parameters per port per Priority .
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtPriorityEntry

prtPriorityEntry 1.3.6.1.4.1.164.6.3.4.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtPriorityEntry  

prtPriorityIdx1 1.3.6.1.4.1.164.6.3.4.1.1.1
This attribute indicates the Idx of the Cnfg(1..255) being accessed ; Idx of 255 relates to the TmpCnfg. or any other Index.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..255  

prtPriorityPrtIdx 1.3.6.1.4.1.164.6.3.4.1.1.2
This object indicates a unique Port Index. Refer to device specification for port Index.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..2147483647  

prtPriorityIdx 1.3.6.1.4.1.164.6.3.4.1.1.3
This object indicates the Traffic Priority Index.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..7  

prtPriorityIngressRateLimit 1.3.6.1.4.1.164.6.3.4.1.1.4
The maximum rate permitted at Ingress of this port with this Traffic Priority, in Kbps.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

prtQosTable 1.3.6.1.4.1.164.6.3.4.2
Port QoS (Quality of Service) table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrtQosEntry

prtQosEntry 1.3.6.1.4.1.164.6.3.4.2.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PrtQosEntry  

prtQosIdx 1.3.6.1.4.1.164.6.3.4.2.1.1
The first index of the table. This attribute might indicate the Idx of the Cnfg (1..255) being accessed ; Idx of 255 relates to the TmpCnfg or any other Index.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

prtQosPrtIdx 1.3.6.1.4.1.164.6.3.4.2.1.2
This object indicates a unique Port Index. Refer to device specification for port Index.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

prtQosDirection 1.3.6.1.4.1.164.6.3.4.2.1.3
This object indicates the port's QoS Direction.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER all(1), ingress(2), egress(3)  

prtQosRateLimitPacketType 1.3.6.1.4.1.164.6.3.4.2.1.4
This object indicates the Type of Packets on which Rate Limitation is applied.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER all(1), bcastAndMcastAndFloodedUcast(2), bcastAndMcast(3), bcast(4)  

prtQosRateLimitCIR 1.3.6.1.4.1.164.6.3.4.2.1.5
This object indicates the port's CIR (Committed Information Rate) in Kbps. Value=0 represents best effort.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

prtQosRateLimitCBS 1.3.6.1.4.1.164.6.3.4.2.1.6
This object indicates the port's CBS (Committed Burst Size) in KB. Value=0 represents best effort.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

prtQosRateLimitEIR 1.3.6.1.4.1.164.6.3.4.2.1.7
This object indicates the port's EIR (Excess Information Rate) in Kbps.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

prtQosRateLimitEBS 1.3.6.1.4.1.164.6.3.4.2.1.8
This object indicates the port's EBS (Excess Burst Size) in KB.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

prtTrafficClass 1.3.6.1.4.1.164.6.3.5
OBJECT IDENTIFIER    

portTrafficClassTable 1.3.6.1.4.1.164.6.3.5.1
Mapping of port to Traffic Class level.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PortTrafficClassEntry

portTrafficClassEntry 1.3.6.1.4.1.164.6.3.5.1.1
An entry in portTrafficClassTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  PortTrafficClassEntry  

portTrafficClassIdx1 1.3.6.1.4.1.164.6.3.5.1.1.1
This attribute indicates the 1st index of the table. This may be the Idx of the Cnfg(1..255) being accessed; Idx of 255 relates to the TmpCnfg, or any other Index.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..255  

portTrafficClassPortIdx 1.3.6.1.4.1.164.6.3.5.1.1.2
This object indicates a unique Port Index. Refer to device specification for port Index.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..2147483647  

portTrafficClass 1.3.6.1.4.1.164.6.3.5.1.1.3
This object indicates the Traffic Class level of this port.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..7  

serviceTable 1.3.6.1.4.1.164.6.3.6
Table of services.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ServiceEntry

serviceEntry 1.3.6.1.4.1.164.6.3.6.1
An entry in the Service Table.
Status: current Access: not-accessible
OBJECT-TYPE    
  ServiceEntry  

flowIndex 1.3.6.1.4.1.164.6.3.6.1.1
Defines the Flow ID the service is associated to.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

serviceIndex 1.3.6.1.4.1.164.6.3.6.1.2
Defines the Service ID - according to the CoS.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..7  

serviceRowStatus 1.3.6.1.4.1.164.6.3.6.1.3
This attribute is used to create a new row or to delete an existing row in the table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

serviceName 1.3.6.1.4.1.164.6.3.6.1.4
This attribute defines the service name.
Status: current Access: read-create
OBJECT-TYPE    
  SnmpAdminString  

serviceBwProfileId 1.3.6.1.4.1.164.6.3.6.1.5
This variable holds the index of the Ingress BW profile assigned to that service.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

evcCosTable 1.3.6.1.4.1.164.6.3.7
This table defines mapping of Ethernet Virtual Connection (EVC) ID to Class of Service (CoS) ID
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    EvcCosEntry

evcCosEntry 1.3.6.1.4.1.164.6.3.7.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  EvcCosEntry  

evcCosCnfgIdx 1.3.6.1.4.1.164.6.3.7.1.1
This attribute indicates the Idx of the Cnfg(1..255) being accessed ; Idx of 255 relates to the TmpCnfg.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 1..255  

evcCosEvcIdx 1.3.6.1.4.1.164.6.3.7.1.2
This attribute indicates EVC Id.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 1..4095  

evcCosRowStatus 1.3.6.1.4.1.164.6.3.7.1.3
This attribute allows to create/delete a row in this table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

evcCosEvcName 1.3.6.1.4.1.164.6.3.7.1.5
A string that identifies the EVC. It should be unique in the Maintenance Domain (i.e., in the managed network) Used as MEG ID field in OAM messages.
Status: current Access: read-create
OBJECT-TYPE    
  SnmpAdminString  

evcCosSpVlanId 1.3.6.1.4.1.164.6.3.7.1.6
This object indicates the SP (Service Provider) VLAN used when sending an OAM message for the specified EVC.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

serviceStatTable 1.3.6.1.4.1.164.6.3.8
Service statistics table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ServiceStatEntry

serviceStatEntry 1.3.6.1.4.1.164.6.3.8.1
An entry in the Service Statistics Table.
Status: current Access: not-accessible
OBJECT-TYPE    
  ServiceStatEntry  

serviceStatDirection 1.3.6.1.4.1.164.6.3.8.1.1
The direction in wich the measurement is taken.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER upstream(1), downstream(2)  

srvForwardGreenPackets 1.3.6.1.4.1.164.6.3.8.1.2
This attribute displays the counted number of forwarded packets that where marked Green.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

srvForwardGreenPacktesOverflow 1.3.6.1.4.1.164.6.3.8.1.3
This attribute displays the number of times that the forwardGreenPackets counter has overflowed.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

srvForwardYellowPackets 1.3.6.1.4.1.164.6.3.8.1.4
This attribute displays the counted number of forwarded packets that where marked Yellow.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

srvForwardYellowPacketsOverflow 1.3.6.1.4.1.164.6.3.8.1.5
This attribute displays the number of times that the forwardYellowPackets counter has overflowed.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

srvDiscardGreenPacket 1.3.6.1.4.1.164.6.3.8.1.6
This attribute displays the counted number of discarded packets that where marked Green.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

srvDiscardGreenPacketOverflow 1.3.6.1.4.1.164.6.3.8.1.7
This attribute displays the number of times that the discardGreenPacket counter has overflowed.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

srvDiscardYellowRedPackets 1.3.6.1.4.1.164.6.3.8.1.8
This attribute displays the counted number of discarded packets that where marked Yellow or Red.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

srvDiscardYellowRedPacketsOverflow 1.3.6.1.4.1.164.6.3.8.1.9
This attribute displays the number of times that the discardYellowRedPackets counter has overflowed.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

srvForwardGreenBytes 1.3.6.1.4.1.164.6.3.8.1.10
This attribute displays the counted number of forwarded bytes that where marked Green.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

srvForwardGreenBytesOverflow 1.3.6.1.4.1.164.6.3.8.1.11
This attribute displays the number of times that the forwardGreenBytes counter has overflowed.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

srvForwardYellowBytes 1.3.6.1.4.1.164.6.3.8.1.12
This attribute displays the counted number of forwarded bytes that where marked Yellow.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

srvForwardYellowBytesOverflow 1.3.6.1.4.1.164.6.3.8.1.13
This attribute displays the number of times that the forwardYellowBytes counter has overflowed.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

srvDiscardGreenBytes 1.3.6.1.4.1.164.6.3.8.1.14
This attribute displays the counted number of discarded bytes that where marked Green.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

srvDiscardGreenBytesOverflow 1.3.6.1.4.1.164.6.3.8.1.15
This attribute displays the number of times that the discardGreenBytes counter has overflowed.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

srvDiscardYellowRedBytes 1.3.6.1.4.1.164.6.3.8.1.16
This attribute displays the counted number of discarded bytes that where marked Yellow or Red.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

srvDiscardYellowRedBytesOverflow 1.3.6.1.4.1.164.6.3.8.1.17
This attribute displays the number of times that the discardYellowRedBytes counter has overflowed.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

srvResetStatsCmd 1.3.6.1.4.1.164.6.3.8.1.18
Reset statistic counters of the service.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER off(2), on(3)  

srvDiscardYellowPackets 1.3.6.1.4.1.164.6.3.8.1.19
This attribute displays the counted number of discarded packets that where marked Yellow.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

srvDiscardYellowPacketsOverflow 1.3.6.1.4.1.164.6.3.8.1.20
This attribute displays the number of times that the discardYellowPackets counter has overflowed.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

srvDiscardYellowBytes 1.3.6.1.4.1.164.6.3.8.1.21
This attribute displays the counted number of discarded bytes that where marked Yellow.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

srvDiscardYellowBytesOverflow 1.3.6.1.4.1.164.6.3.8.1.22
This attribute displays the number of times that the discardYellowBytes counter has overflowed.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

srvDiscardRedPackets 1.3.6.1.4.1.164.6.3.8.1.23
This attribute displays the counted number of discarded packets that where marked Red.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

srvDiscardRedPacketsOverflow 1.3.6.1.4.1.164.6.3.8.1.24
This attribute displays the number of times that the discardRedPackets counter has overflowed.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

srvDiscardRedBytes 1.3.6.1.4.1.164.6.3.8.1.25
This attribute displays the counted number of discarded bytes that where marked Red.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

srvDiscardRedBytesOverflow 1.3.6.1.4.1.164.6.3.8.1.26
This attribute displays the number of times that the discardRedBytes counter has overflowed.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

mappingProfileObjects 1.3.6.1.4.1.164.6.3.9
OBJECT IDENTIFIER    

flowMappingProfileTable 1.3.6.1.4.1.164.6.3.9.1
This table holds flow mapping profiles.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FlowMappingProfileEntry

flowMappingProfileEntry 1.3.6.1.4.1.164.6.3.9.1.1
Each entry in this table describes one Flow mapping profile with one of its Flow Mapping supported, according to the Priority order. The information includes a reference to a Flow Mapping index.
Status: current Access: not-accessible
OBJECT-TYPE    
  FlowMappingProfileEntry  

flowMappingProfileIndex 1.3.6.1.4.1.164.6.3.9.1.1.1
A running index for the Flow Mapping Profile table.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

flowMappingProfilePriority 1.3.6.1.4.1.164.6.3.9.1.1.2
The priority of the Mapping selected by flowMappingProfileMapIndex within the Flow Mapping Profile.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER  

flowMappingProfileRowStatus 1.3.6.1.4.1.164.6.3.9.1.1.3
This attribute is used to create a new row or to delete an existing row in the table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

flowMappingProfileNumOfMaps 1.3.6.1.4.1.164.6.3.9.1.1.4
This attribute determines the number of the mappings associated to the Flow Mapping Profile.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

flowMappingProfileMapIndex 1.3.6.1.4.1.164.6.3.9.1.1.5
This attribute holds a reference to the mapping index. It specifies the mapping selected for the Mapping Profile for the selected Priority. When flowMappingProfileNumOfMaps=0, this attribute is not relevant.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

flowMappingProfileName 1.3.6.1.4.1.164.6.3.9.1.1.6
This attribute defines the name assigned to flowMappingIndex profile.
Status: current Access: read-create
OBJECT-TYPE    
  SnmpAdminString  

qosFlowMappingTable 1.3.6.1.4.1.164.6.3.9.2
A table of Flow Mapping.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    QosFlowMappingEntry

qosFlowMappingEntry 1.3.6.1.4.1.164.6.3.9.2.1
Each entry in this table describes one Flow Mapping. The information includes combination (AND function) of all the classifications, as defined in the qosFlowMappingCriteria field. Classifiers are: TOS, DSCP, VLAN ID, MAC and IP source and destination addresses, IP protocol, IP Precedence, TCP and UDP source and destination ports.
Status: current Access: not-accessible
OBJECT-TYPE    
  QosFlowMappingEntry  

qosFlowMappingIdx1 1.3.6.1.4.1.164.6.3.9.2.1.1
- In case the table is accessed via flowMappingProfileTable this is a running index for the QoS Flow Mapping table. - In case the table is not accessed via flowMappingProfileTable, this will be the ifIndex of the XNI (bridge port) to which the QoS mapping applies.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

qosFlowMappingIdx2 1.3.6.1.4.1.164.6.3.9.2.1.2
An index for the QoS Flow Mapping table. - In case the table is accessed via flowMappingProfileTable the index will be fixed = 1. - In case the table is not accessed via flowMappingProfileTable, this will be the index of the Flow (EVC) to which the QoS mapping applies.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

qosFlowMappingIdx3 1.3.6.1.4.1.164.6.3.9.2.1.3
An index for the QoS Flow Mapping table. - In case the table is accessed via flowMappingProfileTable the index will be fixed = 1. - In case the table is not accessed via flowMappingProfileTable, this will be the Priority to which the QoS mapping applies.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

qosFlowMappingRowStatus 1.3.6.1.4.1.164.6.3.9.2.1.4
This attribute is used to create a new row or to delete an existing row in the table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

qosFlowMappingCriteria 1.3.6.1.4.1.164.6.3.9.2.1.5
This attribute determines upon which criterion the flow will be mapped.
Status: current Access: read-create
OBJECT-TYPE    
  BITS ieee802dot1p(0), tos(1), dscp(2), vlanId(3), macSrcAddr(4), macDestAddr(5), ipSrcAddr(6), ipDestAddr(7), tcpSrcPort(8), tcpDestPort(9), udpSrcPort(10), udpDestPort(11), ipPrecedence(12), innerIeee802dot1p(13), innerVlanId(14), untagged(15)  

qosFlowMappingIeee802dot1p 1.3.6.1.4.1.164.6.3.9.2.1.6
This attribute determines which TOS values are applicable for that flow. Each bit (0..7) represents a different 802.1 P-bit value. Setting '1' to the bit means that the corresponding 802.1 P-bit value is applicable. It is relevant only in case the ieee802dot1p bit(0) in qosFlowMappingCriteria equals 1.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

qosFlowMappingTos 1.3.6.1.4.1.164.6.3.9.2.1.7
This attribute determines which TOS values are applicable for that flow. Each bit (0..7) represents a different TOS value. Setting '1' to the bit means that the corresponding TOS value is applicable. It is relevant only in case the tos bit (1) in qosFlowMappingCriteria equals 1.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

qosFlowMappingFromDscp 1.3.6.1.4.1.164.6.3.9.2.1.8
This attribute determines the first DSCP value to compare with in a range. It is relevant only in case the dscp bit (2) in qosFlowMappingCriteria equals 1.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

qosFlowMappingToDscp 1.3.6.1.4.1.164.6.3.9.2.1.9
This attribute determines the first DSCP value to compare with in a range. It is relevant only in case the dscp bit (2) in qosFlowMappingCriteria equals 1.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

qosFlowMappingFromVlanId 1.3.6.1.4.1.164.6.3.9.2.1.10
This attribute determines the first VLAN ID value to compare with in a range. It is relevant only in case the vlanId bit (3) in qosFlowMappingCriteria equals 1.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

qosFlowMappingToVlanId 1.3.6.1.4.1.164.6.3.9.2.1.11
This attribute determines the last VLAN ID value to compare with in a range. It is relevant only in case the vlanId bit (3) in qosFlowMappingCriteria equals 1.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

qosFlowMappingFromSrcMacAddr 1.3.6.1.4.1.164.6.3.9.2.1.12
This attribute determines the first source MAC address to compare with in a range. It is relevant only in case the macSrcAddr bit (4) in qosFlowMappingCriteria equals 1.
Status: current Access: read-create
OBJECT-TYPE    
  MacAddress  

qosFlowMappingToSrcMacAddr 1.3.6.1.4.1.164.6.3.9.2.1.13
This attribute determines the last source MAC address to compare with in a range. It is relevant only in case the macSrcAddr bit (4) in qosFlowMappingCriteria equals 1.
Status: current Access: read-create
OBJECT-TYPE    
  MacAddress  

qosFlowMappingFromDestMacAddr 1.3.6.1.4.1.164.6.3.9.2.1.14
This attribute determines the first destination MAC address to compare with in a range. It is relevant only in case the macDestAddr (5) bit in qosFlowMappingCriteria equals 1.
Status: current Access: read-create
OBJECT-TYPE    
  MacAddress  

qosFlowMappingToDestMacAddr 1.3.6.1.4.1.164.6.3.9.2.1.15
This attribute determines the last destination MAC address to compare with in a range. It is relevant only in case the macDestAddr (5) bit in qosFlowMappingCriteria equals 1.
Status: current Access: read-create
OBJECT-TYPE    
  MacAddress  

qosFlowMappingFromSrcIpAddr 1.3.6.1.4.1.164.6.3.9.2.1.16
This attribute determines the first source IP address to compare with in a range. It is relevant only in case the ipSrcAddr (6) bit in qosFlowMappingCriteria equals 1.
Status: current Access: read-create
OBJECT-TYPE    
  IpAddress  

qosFlowMappingToSrcIpAddr 1.3.6.1.4.1.164.6.3.9.2.1.17
This attribute determines the last source IP address to compare with in a range. It is relevant only in case the ipSrcAddr (6) bit in qosFlowMappingCriteria equals 1.
Status: current Access: read-create
OBJECT-TYPE    
  IpAddress  

qosFlowMappingFromDestIpAddr 1.3.6.1.4.1.164.6.3.9.2.1.18
This attribute determines the first destination IP address to compare with in a range. It is relevant only in case the ipDestAddr (7) bit in qosFlowMappingCriteria equals 1.
Status: current Access: read-create
OBJECT-TYPE    
  IpAddress  

qosFlowMappingToDestIpAddr 1.3.6.1.4.1.164.6.3.9.2.1.19
This attribute determines the last destination IP address to compare with in a range. It is relevant only in case the ipDestAddr (7) bit in qosFlowMappingCriteria equals 1.
Status: current Access: read-create
OBJECT-TYPE    
  IpAddress  

qosFlowMappingFromTcpSrcPort 1.3.6.1.4.1.164.6.3.9.2.1.20
This attribute determines the first TCP source port to compare with in a range. It is relevant only in case the tcpSrcPort bit (8) in qosFlowMappingCriteria equals 1.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

qosFlowMappingToTcpSrcPort 1.3.6.1.4.1.164.6.3.9.2.1.21
This attribute determines the last TCP source port to compare with in a range. It is relevant only in case the tcpSrcPort bit (8) in qosFlowMappingCriteria equals 1.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

qosFlowMappingFromTcpDestPort 1.3.6.1.4.1.164.6.3.9.2.1.22
This attribute determines the first TCP destination port to compare with in a range. It is relevant only in case the tcpDestPort bit (9) in qosFlowMappingCriteria equals 1.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

qosFlowMappingToTcpDestPort 1.3.6.1.4.1.164.6.3.9.2.1.23
This attribute determines the last TCP destination port to compare with in a range. It is relevant only in case the tcpDestPort bit (9) in qosFlowMappingCriteria equals 1.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

qosFlowMappingFromUdpSrcPort 1.3.6.1.4.1.164.6.3.9.2.1.24
This attribute determines the first UDP source port to compare with in a range. It is relevant only in case the udpSrcPort bit (10) in qosFlowMappingCriteria equals 1.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

qosFlowMappingToUdpSrcPort 1.3.6.1.4.1.164.6.3.9.2.1.25
This attribute determines the last UDP source port to compare with in a range. It is relevant only in case the udpSrcPort bit (10) in qosFlowMappingCriteria equals 1.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

qosFlowMappingFromUdpDestPort 1.3.6.1.4.1.164.6.3.9.2.1.26
This attribute determines the first UDP destination port to compare with in a range. It is relevant only in case the udpDestPort bit (11) in qosFlowMappingCriteria equals 1.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

qosFlowMappingToUdpDestPort 1.3.6.1.4.1.164.6.3.9.2.1.27
This attribute determines the last UDP destination port to compare with in a range. It is relevant only in case the udpDestPort bit (11) in qosFlowMappingCriteria equals 1.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

qosFlowMappingFromIpPrecedence 1.3.6.1.4.1.164.6.3.9.2.1.28
This attribute determines the first IpPrecedence value to compare with in a range. It is relevant only in case the IpPrecedence bit (12) in qosFlowMappingCriteria equals 1.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

qosFlowMappingToIpPrecedence 1.3.6.1.4.1.164.6.3.9.2.1.29
This attribute determines the last IpPrecedence value to compare with in a range. It is relevant only in case the IpPrecedence bit (12) in qosFlowMappingCriteria equals 1.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

qosFlowMappingInnerIeee802dot1p 1.3.6.1.4.1.164.6.3.9.2.1.30
This attribute determines which TOS values are applicable for that flow. Each bit (0..7) represents a different inner 802.1 P-bit value. Setting '1' to the bit means that the corresponding inner 802.1 P-bit value is applicable. It is relevant only in case the innerIeee802dot1p bit (13) in qosFlowMappingCriteria equals 1.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

qosFlowMappingFromInnerVlanId 1.3.6.1.4.1.164.6.3.9.2.1.31
This attribute determines the first inner VLAN ID value to compare with in a range. It is relevant only in case the innerVlanId bit(14) in qosFlowMappingCriteria equals 1.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

qosFlowMappingToInnerVlanId 1.3.6.1.4.1.164.6.3.9.2.1.32
This attribute determines the last inner VLAN ID value to compare with in a range. It is relevant only in case the innerVlanId bit(14) in qosFlowMappingCriteria equals 1.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

cosProfileTable 1.3.6.1.4.1.164.6.3.10
Class of Service Profile table. Each profile holds a priority method, and a mappring function that maps the priority values (range according to the method) into CoS values.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CosProfileEntry

cosProfileEntry 1.3.6.1.4.1.164.6.3.10.1
A conceptual row where each row contains one CoS attributes.
Status: current Access: not-accessible
OBJECT-TYPE    
  CosProfileEntry  

cosProfileIndex 1.3.6.1.4.1.164.6.3.10.1.1
Defines the CoS Profile ID.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

cosProfileRowStatus 1.3.6.1.4.1.164.6.3.10.1.2
This attribute is used to create a new row or to delete an existing row in the table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

cosProfileCosMethod 1.3.6.1.4.1.164.6.3.10.1.3
Defines the priority method upon CoS mapping is done.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER ieee802dot1p(2), tos(3), dscp(4), ipPrecedence(5)  

cosProfileName 1.3.6.1.4.1.164.6.3.10.1.4
This attribute defines the name assigned to CoS profile.
Status: current Access: read-create
OBJECT-TYPE    
  SnmpAdminString  

cosProfileCosMapping 1.3.6.1.4.1.164.6.3.10.1.5
This attribute defines the value of the CoS that is assigned for each priority. The number of the valid octets depends upon the priority method selected: Octet 0 corresponds to priority = 0 Octet 1 corresponds to priority = 1 ... Octet 63 corresponds to priority = 63.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING Size(0..63)  

queueProfileObjects 1.3.6.1.4.1.164.6.3.11
OBJECT IDENTIFIER    

qProfileTable 1.3.6.1.4.1.164.6.3.11.1
This table defines the profiles for a cluster of queues.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    QProfileEntry

qProfileEntry 1.3.6.1.4.1.164.6.3.11.1.1
A conceptual row where each row contains one Queue Cluster attribute.
Status: current Access: not-accessible
OBJECT-TYPE    
  QProfileEntry  

qProfileIndex 1.3.6.1.4.1.164.6.3.11.1.1.1
Defines the Queue Cluster Profile ID.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

qProfileRowStatus 1.3.6.1.4.1.164.6.3.11.1.1.2
This attribute is used to create a new row or to delete an existing row in the table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

qProfileName 1.3.6.1.4.1.164.6.3.11.1.1.3
This attribute holds the name of the Queue cluster profile.
Status: current Access: read-create
OBJECT-TYPE    
  SnmpAdminString  

qProfileNumberOfInternalQ 1.3.6.1.4.1.164.6.3.11.1.1.4
This attribute holds the number of the internal queue profiles that are pointed by qInternalQProfile.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

qProfileInternalQProfile 1.3.6.1.4.1.164.6.3.11.1.1.5
This attribute holds the indexes to the queue profiles in the qInternalProfileTable. Each couple of octets holds an index to the qInternalProfileTable.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING  

qInternalProfileTable 1.3.6.1.4.1.164.6.3.11.2
This table holds queue profiles.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    QInternalProfileEntry

qInternalProfileEntry 1.3.6.1.4.1.164.6.3.11.2.1
A conceptual row where each row contains one Queue attribute.
Status: current Access: not-accessible
OBJECT-TYPE    
  QInternalProfileEntry  

qInternalProfileIndex 1.3.6.1.4.1.164.6.3.11.2.1.1
Defines the Queue Profile ID.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

qInternalProfileRowStatus 1.3.6.1.4.1.164.6.3.11.2.1.2
This attribute is used to create a new row or to delete an existing row in the table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

qInternalProfileScheduling 1.3.6.1.4.1.164.6.3.11.2.1.3
This attribute determines the queue scheduling method.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER wfq(1), strict(2), bestEffort(3)  

qInternalProfileWFQWeight 1.3.6.1.4.1.164.6.3.11.2.1.4
This attribute determines the weight that each WFQ (Weighted Fair Queue) participant gets. It is applicable only when scheduling is configured to WFQ.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

qInternalProfileQueueLength 1.3.6.1.4.1.164.6.3.11.2.1.5
This attribute determines the length of the queue.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

qInternalProfileWredStartDropThresh 1.3.6.1.4.1.164.6.3.11.2.1.6
This attribute determines the length that the queue (Start Value) must reach before the packets colored yellow will start being dropped by the WRED (Weighted Random Early Detection/Discard) mechanism. WRED is one the most commonly used method for congestion avoidance.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

qInternalProfileWredDropAllThresh 1.3.6.1.4.1.164.6.3.11.2.1.7
This attribute determines the length that the queue (Stop Value) must reach before the WRED (Weighted Random Early Detection) shaper mechanism stops dropping randomly, and just drops all further packets marked as yellow.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

qInternalProfileWredDropProbability 1.3.6.1.4.1.164.6.3.11.2.1.8
This attribute determines the percentage of packets that are being dropped at the point when the length of the queue reaches the Stop value. So, effectively, this defines how quickly the rate of dropping packet must increase as the queue length grows from the Start Value to the Stop Value.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

qInternalProfileRateLimit 1.3.6.1.4.1.164.6.3.11.2.1.9
This attribute determines the Rate Limit of the queue in Kbps. Value=0 represents best effort.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

qInternalProfileShaperProfile 1.3.6.1.4.1.164.6.3.11.2.1.10
This attribute defines the Shaper Profile (bwProfileIndex from bwProfileTable) assigned to this qInternalProfile. Valid range of bwProfileIndex for Shaper Profiles is 0x8000001-0x8000041. If set to '0', no profile is assigned to this qInternalProfile.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

queueGroupTable 1.3.6.1.4.1.164.6.3.11.3
This table defines the queue groups/blocks,their level and connections between them.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    QueueGroupEntry

queueGroupEntry 1.3.6.1.4.1.164.6.3.11.3.1
A conceptual row where each row contains one Queue group.
Status: current Access: not-accessible
OBJECT-TYPE    
  QueueGroupEntry  

queueGroupName 1.3.6.1.4.1.164.6.3.11.3.1.1
Defines the Queue Group unique name.
Status: current Access: not-accessible
OBJECT-TYPE    
  SnmpAdminString Size(1..32)  

queueGroupQBlockLevel 1.3.6.1.4.1.164.6.3.11.3.1.2
This attribute holds the Level of the Queue Block .First level is 1. NA=2^32-1.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

queueGroupQBlockIdx 1.3.6.1.4.1.164.6.3.11.3.1.3
This attribute holds the ID of the Queue Block. NA=2^32-1.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

queueGroupRowStatus 1.3.6.1.4.1.164.6.3.11.3.1.4
This attribute is used to create a new row or to delete an existing row in the table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

queueGroupQBlockProfile 1.3.6.1.4.1.164.6.3.11.3.1.5
This attribute defines the Queue profile assigned to this Queue Block. This object points to qProfileIndex in qProfileTable.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

queueGroupQBlockShaperProfile 1.3.6.1.4.1.164.6.3.11.3.1.6
This attribute defines the Shaper profile assigned to this Queue Block.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

queueGroupPointToQBlock 1.3.6.1.4.1.164.6.3.11.3.1.7
This attribute defines the Queue Block name of the next Queue Block level that is pointed by this Queue Block.
Status: current Access: read-create
OBJECT-TYPE    
  SnmpAdminString Size(1..32)  

queueGroupPointToInternalQueue 1.3.6.1.4.1.164.6.3.11.3.1.8
This attribute defines the internal queue whithin queueGroupPointToQBlock that is pointed by this Queue Block.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

queueGroupQBlockName 1.3.6.1.4.1.164.6.3.11.3.1.9
This attribute holds the name of the Queue Block.
Status: current Access: read-create
OBJECT-TYPE    
  SnmpAdminString Size(1..32)  

markingProfileTable 1.3.6.1.4.1.164.6.3.12
Marking profile table. Each profile holds a marking function which converts CoS values to Service Provider priority values.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MarkingProfileEntry

markingProfileEntry 1.3.6.1.4.1.164.6.3.12.1
A conceptual row where each row contains one Marking attribute.
Status: current Access: not-accessible
OBJECT-TYPE    
  MarkingProfileEntry  

markingProfileIndex 1.3.6.1.4.1.164.6.3.12.1.1
Defines the Marking Profile ID.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

markingProfileRowStatus 1.3.6.1.4.1.164.6.3.12.1.2
This attribute is used to create a new row or to delete an existing row in the table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

markingProfileName 1.3.6.1.4.1.164.6.3.12.1.3
This attribute defines the unique name assigned to the Marking profile.
Status: current Access: read-create
OBJECT-TYPE    
  SnmpAdminString  

markingSpVlanPBit 1.3.6.1.4.1.164.6.3.12.1.4
For ETX-202A : This attribute defines the value of the SP VLAN P-Bit that is assigned for each CoS: Octet 0 corresponds to CoS = 0 Octet 1 corresponds to CoS = 1 ... Octet 7 corresponds to CoS = 7. For LA-210 from V1.5 : This attribute defines the value of the SP VLAN P-Bit that is assigned for each frame according to the value of markingProfileMethod parameter : Octet 0 corresponds to value 0 of 802.1 P-bit/DSCP/TOS. Octet 1 corresponds to value 1 of 802.1 P-bit/DSCP/TOS. ... Octet 7 corresponds to value 7 of 802.1 P-bit/DSCP/TOS. Octets 8-63 correspond to DSCP values 8-63.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING Size(0..63)  

markingProfileMethod 1.3.6.1.4.1.164.6.3.12.1.5
This attribute defines the method upon which marking is done.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER ieee802dot1p(2), tos(3), dscp(4), ipPrecedence(5)  

ethIf 1.3.6.1.4.1.164.3.1.6.1
OBJECT IDENTIFIER    

ethIfTable 1.3.6.1.4.1.164.3.1.6.1.1
A table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    EthIfEntry

ethIfEntry 1.3.6.1.4.1.164.3.1.6.1.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  EthIfEntry  

ethIfIdx 1.3.6.1.4.1.164.3.1.6.1.1.1.1
A unique index of the ethernet interface/port.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ethMode 1.3.6.1.4.1.164.3.1.6.1.1.1.2
This object indicates the Ethernet mode of operation.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER halfDuplex(1), fullDuplex(2), notApplicable(255)  

ethBridgingMode 1.3.6.1.4.1.164.3.1.6.1.1.1.3
This object indicates the bridging mode of the Ethernet interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER filtered(1), transparent(2)  

ethEncapsulationCRCMode 1.3.6.1.4.1.164.3.1.6.1.1.1.4
This object define the encapsulation type requested for the Ethernet interface. It indicates if we transfer the Ethernet frame to the other side with or without the CRC.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), withCRC(2), withoutCRC(3)  

ethBackPressure 1.3.6.1.4.1.164.3.1.6.1.1.1.5
This parameter defines whether to enable or disable Back pressure. Back Pressure is a flow control parameter.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

ethLimit4 1.3.6.1.4.1.164.3.1.6.1.1.1.6
This parameter determine the Back off algorithm mode. Every 4 following collisions the Framer will be thrown out (4 times more than usuall).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

ethSkipInitReset 1.3.6.1.4.1.164.3.1.6.1.1.1.7
This parameter defines whether read status on reset.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), notSkip(2), skip(3)  

ethMulticastBlock 1.3.6.1.4.1.164.3.1.6.1.1.1.8
This parameter defines whether to send multicast message to WAN from LAN or not.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), unBlock(2), block(3)  

ethBroadcastBlock 1.3.6.1.4.1.164.3.1.6.1.1.1.9
This parameter defines whether to send broadcast message to WAN from LAN or not.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), unBlock(2), block(3)  

ethSpeed 1.3.6.1.4.1.164.3.1.6.1.1.1.10
This parameter defines the line speed.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), s10Mbps(2), s100Mbps(3), s1Gbps(4)  

ethRip2 1.3.6.1.4.1.164.3.1.6.1.1.1.11
This parameter defines whether to send RIP II message to WAN from LAN or not
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

ethPortPriority 1.3.6.1.4.1.164.3.1.6.1.1.1.12
This parameter defines if priority is to be considered for this Port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), none(2), fixed(3)  

ethPortMngEnable 1.3.6.1.4.1.164.3.1.6.1.1.1.13
This parameter defines whether management data can pass through this Port. localOnly (4) - Only local device can be managed via this port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3), localOnly(4)  

ethFlowCtrlMacAddress 1.3.6.1.4.1.164.3.1.6.1.1.1.14
In case of flow control - transmit frame with this specific MAC address to inform the other end to stop sending frames. Default: 01.80.C2.00.00.01.
Status: current Access: read-write
OBJECT-TYPE    
  MacAddress  

ethRateLimit 1.3.6.1.4.1.164.3.1.6.1.1.1.15
This parameter defines the Rate Limit of the line, in Mbps.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

ethJumboFrameEnable 1.3.6.1.4.1.164.3.1.6.1.1.1.16
This parameter defines whether to support Jumbo Frame or not.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

ethAutoMdiXEnable 1.3.6.1.4.1.164.3.1.6.1.1.1.17
This parameter defines whether to support automatic change between MDI and MDI[X].
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

ethPortDataEnable 1.3.6.1.4.1.164.3.1.6.1.1.1.18
This parameter defines whether this port is enabled for data (that is not management). no(2) - management can run on this port yes(3) - both management and payload data can run on this port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

ethIfUse 1.3.6.1.4.1.164.3.1.6.1.1.1.19
This parameter defines the use of the port. 1=NET 2=USER .
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

ethLineOam 1.3.6.1.4.1.164.3.1.6.1.1.1.20
This parameter defines the working mode of 802.AH OAM mechanism.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(2), passive(3)  

ethRoutingProtocol 1.3.6.1.4.1.164.3.1.6.1.1.1.21
This parameter defines the routing protocol used above ETH port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), none(2), proprietary(3), rip2(4), rip1and2(6)  

ethMdiXManualSwitch 1.3.6.1.4.1.164.3.1.6.1.1.1.22
This parameter sets the port to be MDI-X (cross-over) or MDI (straight-through). It is applicable only when ethAutoMdiXEnable = no, namely, only when the automatic MDI/MDIX crossover function is disabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER crossOver(1), straightThrough(2)  

ethDot1xEnable 1.3.6.1.4.1.164.3.1.6.1.1.1.23
Determines if the Port-Based Network Access Protocol (IEEE-802.1x) is enabled for the Ethernet Port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), no(2), yes(3)  

ethPartnerRateMode 1.3.6.1.4.1.164.3.1.6.1.1.1.24
For converters having couples of ports, where each couple contains a port with an SFP connector and a port with a RJ connector, this parameter is relevant for the SFP port. It affects Rate configuration of its partner (RJ port). manual - user can configure manually ETH parameters of RJ port (e.g Autonegotiation, Max Capability Advertised, etc...) automatic - SFP Rate will be enforced on the RJ port. In this mode, user cannot configure the Rate related parameters of the RJ port (e.g Autonegotiation, Max Capability Advertised, etc...)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER manual(1), automatic(2)  

ethDot1xPortRole 1.3.6.1.4.1.164.3.1.6.1.1.1.25
Determine the functionality of the port in the Port-Based Network Access Protocol (IEEE-802.1x) - either Authenticator or Supplicant.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER authenticator(1), supplicant(2)  

ethIfPerformance 1.3.6.1.4.1.164.3.1.6.1.2
OBJECT IDENTIFIER    

ethIfCurrentTable 1.3.6.1.4.1.164.3.1.6.1.2.1
The Ethernet Current table. When the index specifies the Ethernet interface (only), the counters are for an interval of 15 minutes.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    EthIfCurrentEntry

ethIfCurrentEntry 1.3.6.1.4.1.164.3.1.6.1.2.1.1
An entry in the Ethernet Current table.
Status: current Access: not-accessible
OBJECT-TYPE    
  EthIfCurrentEntry  

ethIfCurrentIndex 1.3.6.1.4.1.164.3.1.6.1.2.1.1.1
The index of the Ethernet interface. It may be ifIndex. For some devices (e.g RICi-622GE), supporting several types of intervals, this index will be a concatenation of the port index and interval type. Interval type can indicate: 1 minute, 15 minutes, 1 hour, 24 hours. For the exact formula, see device specification.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ethIfCurrentStatus 1.3.6.1.4.1.164.3.1.6.1.2.1.1.2
The status of the current interval: 0 - Valid. 1 - redundantLinkSwitch - the link has been switched by a redundancy mechanism. 2 - discontinuity - module was partialy out. 4 - notValid - module is out.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(4)  

ethIfCurrentInFrames 1.3.6.1.4.1.164.3.1.6.1.2.1.1.3
The counter associated with the number of received frames, encountered by the Ethernet interface in the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfCurrentInOctets 1.3.6.1.4.1.164.3.1.6.1.2.1.1.4
The counter associated with the number of received octets, encountered by the Ethernet interface in the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfCurrentAlignmentErrors 1.3.6.1.4.1.164.3.1.6.1.2.1.1.5
The counter associated with the number of received frames, which are not complete (The result of dividing the number of bits by 8 is not an Integer), encountered by the Ethernet interface in the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfCurrentFCSErrors 1.3.6.1.4.1.164.3.1.6.1.2.1.1.6
The counter associated with the number of received frames that didn't pass the FCS test, encountered by the Ethernet interface in the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfCurrentLengthError 1.3.6.1.4.1.164.3.1.6.1.2.1.1.7
The counter associated with the number of received frames with length error, encountered by the Ethernet interface in the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfCurrentOutFrames 1.3.6.1.4.1.164.3.1.6.1.2.1.1.8
The counter associated with the number of transmitted frames, encountered by the Ethernet interface in the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfCurrentOutOctets 1.3.6.1.4.1.164.3.1.6.1.2.1.1.9
The counter associated with the number of transmitted octets, encountered by the Ethernet interface in the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfCurrentSingleCollisionFrames 1.3.6.1.4.1.164.3.1.6.1.2.1.1.10
The counter associated with the number of successfully transmitted frames for which transmission was inhibited by exactly one collision, encountered by the Ethernet interface in the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfCurrentMultipleCollisionFrames 1.3.6.1.4.1.164.3.1.6.1.2.1.1.11
The counter associated with the number of successfully transmitted frames for which transmission was inhibited by more than one collision, encountered by the Ethernet interface in the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfCurrentDeferredTransmissions 1.3.6.1.4.1.164.3.1.6.1.2.1.1.12
The counter associated with the number of transmitted frames for which the first transmission attempt was delayed due to a busy media, encountered by the Ethernet interface in the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfCurrentLateCollisions 1.3.6.1.4.1.164.3.1.6.1.2.1.1.13
The counter associated with the number of times that a collision was detected later than the first 64 bytes of the frame, encountered by the Ethernet interface in the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfCurrentCarrierSenseErrors 1.3.6.1.4.1.164.3.1.6.1.2.1.1.14
The counter associated with the number of times that the carrier sense condition was lost or never asserted when attempting to transmit a frame, encountered by the Ethernet interface in the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfCurrentInputCongestionDropped 1.3.6.1.4.1.164.3.1.6.1.2.1.1.15
The counter associated with the number of frames dropped due to lack of buffers in ingress pool, encountered by the Ethernet interface in the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfCurrentOutputCongestionDropped 1.3.6.1.4.1.164.3.1.6.1.2.1.1.16
The counter associated with the number of dropped frames due to a congestion, encountered by the Transmit direction to the Ethernet interface in the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfCurrentOverflowInFrames 1.3.6.1.4.1.164.3.1.6.1.2.1.1.17
The number of times the associated ethIfCurrentInFrames counter has overflowed in the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfCurrentOverflowInOctets 1.3.6.1.4.1.164.3.1.6.1.2.1.1.18
The number of times the associated ethIfCurrentInOctets counter has overflowed in the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfCurrentOverflowFCSErrors 1.3.6.1.4.1.164.3.1.6.1.2.1.1.19
The number of times the associated ethIfCurrentFCSErrors counter has overflowed in the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfCurrentOverflowOutFrames 1.3.6.1.4.1.164.3.1.6.1.2.1.1.20
The number of times the associated ethIfCurrentOutFrames counter has overflowed in the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfCurrentOverflowOutOctets 1.3.6.1.4.1.164.3.1.6.1.2.1.1.21
The number of times the associated ethIfCurrentOutOctets counter has overflowed in the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfCurrentOverflowMultipleCollisionFrames 1.3.6.1.4.1.164.3.1.6.1.2.1.1.22
The number of times the associated ethIfCurrentMultipleCollisionFrames counter has overflowed in the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfCurrentInUnicastFrames 1.3.6.1.4.1.164.3.1.6.1.2.1.1.23
The number of received Unicast frames, encountered by the Ethernet interface in the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfCurrentOutUnicastFrames 1.3.6.1.4.1.164.3.1.6.1.2.1.1.24
The number of transmitted Unicast frames, encountered by the Ethernet interface in the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfCurrentInMulticastFrames 1.3.6.1.4.1.164.3.1.6.1.2.1.1.25
The number of received Multicast frames, encountered by the Ethernet interface in the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfCurrentOutMulticastFrames 1.3.6.1.4.1.164.3.1.6.1.2.1.1.26
The number of transmitted Multicast frames, encountered by the Ethernet interface in the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfCurrentInBroadcastFrames 1.3.6.1.4.1.164.3.1.6.1.2.1.1.27
The number of received Broadcast frames, encountered by the Ethernet interface in the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfCurrentOutBroadcastFrames 1.3.6.1.4.1.164.3.1.6.1.2.1.1.28
The number of transmitted Broadcast frames, encountered by the Ethernet interface in the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfCurrentInDiscardFrames 1.3.6.1.4.1.164.3.1.6.1.2.1.1.29
The number of received Discarded frames, encountered by the Ethernet interface in the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfCurrentOutDiscardFrames 1.3.6.1.4.1.164.3.1.6.1.2.1.1.30
The number of transmitted Discarded frames, encountered by the Ethernet interface in the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfCurrentInPauseFrames 1.3.6.1.4.1.164.3.1.6.1.2.1.1.31
The number of received Pause frames, encountered by the Ethernet interface in the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfCurrentOutPauseFrames 1.3.6.1.4.1.164.3.1.6.1.2.1.1.32
The number of transmitted Pause frames, encountered by the Ethernet interface in the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfCurrentOverflowInUnicastFrames 1.3.6.1.4.1.164.3.1.6.1.2.1.1.33
The number of times the associated ethIfCurrentInUnicastFrames counter has overflowed in the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfCurrentOverflowOutUnicastFrames 1.3.6.1.4.1.164.3.1.6.1.2.1.1.34
The number of times the associated ethIfCurrentOutUnicastFrames counter has overflowed in the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfCurrentOverflowInMulticastFrames 1.3.6.1.4.1.164.3.1.6.1.2.1.1.35
The number of times the associated ethIfCurrentInMulticastFrames counter has overflowed in the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfCurrentOverflowOutMulticastFrames 1.3.6.1.4.1.164.3.1.6.1.2.1.1.36
The number of times the associated ethIfCurrentOutMulticastFrames counter has overflowed in the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfCurrentOverflowInBroadcastFrames 1.3.6.1.4.1.164.3.1.6.1.2.1.1.37
The number of times the associated ethIfCurrentInBroadcastFrames counter has overflowed in the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfCurrentOverflowOutBroadcastFrames 1.3.6.1.4.1.164.3.1.6.1.2.1.1.38
The number of times the associated ethIfCurrentOutBroadcastFrames counter has overflowed in the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfCurrentOverflowInDiscardFrames 1.3.6.1.4.1.164.3.1.6.1.2.1.1.39
The number of times the associated ethIfCurrentInDiscardFrames counter has overflowed in the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfCurrentOverflowOutDiscardFrames 1.3.6.1.4.1.164.3.1.6.1.2.1.1.40
The number of times the associated ethIfCurrentOutDiscardFrames counter has overflowed in the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfCurrentOverflowInPauseFrames 1.3.6.1.4.1.164.3.1.6.1.2.1.1.41
The number of times the associated ethIfCurrentInPauseFrames counter has overflowed in the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfCurrentOverflowOutPauseFrames 1.3.6.1.4.1.164.3.1.6.1.2.1.1.42
The number of times the associated ethIfCurrentOutPauseFrames counter has overflowed in the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfIntervalTable 1.3.6.1.4.1.164.3.1.6.1.2.2
The Ethernet Interval table. When ethIfIntervalIndex specifies the Ethernet interface (only), the counters are for an interval of 15 minutes.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    EthIfIntervalEntry

ethIfIntervalEntry 1.3.6.1.4.1.164.3.1.6.1.2.2.1
An entry in the Ethernet Interval table.
Status: current Access: not-accessible
OBJECT-TYPE    
  EthIfIntervalEntry  

ethIfIntervalIndex 1.3.6.1.4.1.164.3.1.6.1.2.2.1.1
The index of the Ethernet interface. It may be ifIndex. For some devices (e.g RICi-622GE), supporting several types of intervals, this index will be a concatenation of the port index and interval type. Interval type can indicate: 1 minute, 15 minutes, 1 hour, 24 hours. For the exact formula, see device specification.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ethIfIntervalNumber 1.3.6.1.4.1.164.3.1.6.1.2.2.1.2
The Interval Number. This number is between 1 and x, where 1 is the most recently completed interval and x is the least recently completed interval. For 15 minute intervals, usually x=96, but it can be different, depending on device capabilities.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..200  

ethIfIntervalStatus 1.3.6.1.4.1.164.3.1.6.1.2.2.1.3
The status of the interval: 0 - Valid. 1 - redundantLinkSwitch - the link has been switched by a redundancy mechanism. 2 - discontinuity - module was partialy out. 4 - notValid - module is out.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(4)  

ethIfIntervalInFrames 1.3.6.1.4.1.164.3.1.6.1.2.2.1.4
The counter associated with the number of received frames, encountered by the Ethernet interface in the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfIntervalInOctets 1.3.6.1.4.1.164.3.1.6.1.2.2.1.5
The counter associated with the number of received octets, encountered by the Ethernet interface in the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfIntervalAlignmentErrors 1.3.6.1.4.1.164.3.1.6.1.2.2.1.6
The counter associated with the number of received frames, which are not complete (The result of dividing the number of bits by 8 is not an Integer), encountered by the Ethernet interface in the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfIntervalFCSErrors 1.3.6.1.4.1.164.3.1.6.1.2.2.1.7
The counter associated with the number of received frames that didn't pass the FCS test, encountered by the Ethernet interface in the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfIntervalLengthError 1.3.6.1.4.1.164.3.1.6.1.2.2.1.8
The counter associated with the number of received frames with length error, encountered by the Ethernet interface in the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfIntervalOutFrames 1.3.6.1.4.1.164.3.1.6.1.2.2.1.9
The counter associated with the number of transmitted frames, encountered by the Ethernet interface in the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfIntervalOutOctets 1.3.6.1.4.1.164.3.1.6.1.2.2.1.10
The counter associated with the number of transmitted octets, encountered by the Ethernet interface in the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfIntervalSingleCollisionFrames 1.3.6.1.4.1.164.3.1.6.1.2.2.1.11
The counter associated with the number of successfully transmitted frames for which transmission was inhibited by exactly one collision, encountered by the Ethernet interface in the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfIntervalMultipleCollisionFrames 1.3.6.1.4.1.164.3.1.6.1.2.2.1.12
The counter associated with the number of successfully transmitted frames for which transmission was inhibited by more than one collision, encountered by the Ethernet interface in the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfIntervalDeferredTransmissions 1.3.6.1.4.1.164.3.1.6.1.2.2.1.13
The counter associated with the number of transmitted frames for which the first transmission attempt was delayed due to a busy media, encountered by the Ethernet interface in the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfIntervalLateCollisions 1.3.6.1.4.1.164.3.1.6.1.2.2.1.14
The counter associated with the number of times that a collision was detected later than the first 64 bytes of the frame, encountered by the Ethernet interface in the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfIntervalCarrierSenseErrors 1.3.6.1.4.1.164.3.1.6.1.2.2.1.15
The counter associated with the number of times that the carrier sense condition was lost or never asserted when attempting to transmit a frame, encountered by the Ethernet interface in the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfIntervalInputCongestionDropped 1.3.6.1.4.1.164.3.1.6.1.2.2.1.16
The counter associated with the number of dropped frames due to a congestion, encountered by the Receive direction to the Ethernet interface in the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfIntervalOutputCongestionDropped 1.3.6.1.4.1.164.3.1.6.1.2.2.1.17
The counter associated with the number of dropped frames due to a congestion, encountered by the Transmit direction to the Ethernet interface in the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfIntervalOverflowInFrames 1.3.6.1.4.1.164.3.1.6.1.2.2.1.18
The number of times the associated ethIfIntervalInFrames counter has overflowed in the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfIntervalOverflowInOctets 1.3.6.1.4.1.164.3.1.6.1.2.2.1.19
The number of times the associated ethIfIntervalInOctets counter has overflowed in the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfIntervalOverflowFCSErrors 1.3.6.1.4.1.164.3.1.6.1.2.2.1.20
The number of times the associated ethIfIntervalFCSErrors counter has overflowed in the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfIntervalOverflowOutFrames 1.3.6.1.4.1.164.3.1.6.1.2.2.1.21
The number of times the associated ethIfIntervalOutFrames counter has overflowed in the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfIntervalOverflowOutOctets 1.3.6.1.4.1.164.3.1.6.1.2.2.1.22
The number of times the associated ethIfIntervalOutOctets counter has overflowed in the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfIntervalOverflowMultipleCollisionFrames 1.3.6.1.4.1.164.3.1.6.1.2.2.1.23
The number of times the associated ethIfIntervalMultipleCollisionFrames counter has overflowed in the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfIntervalInUnicastFrames 1.3.6.1.4.1.164.3.1.6.1.2.2.1.24
The number of received Unicast frames, encountered by the Ethernet interface in the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfIntervalOutUnicastFrames 1.3.6.1.4.1.164.3.1.6.1.2.2.1.25
The number of transmitted Unicast frames, encountered by the Ethernet interface in the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfIntervalInMulticastFrames 1.3.6.1.4.1.164.3.1.6.1.2.2.1.26
The number of received Multicast frames, encountered by the Ethernet interface in the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfIntervalOutMulticastFrames 1.3.6.1.4.1.164.3.1.6.1.2.2.1.27
The number of transmitted Multicast frames, encountered by the Ethernet interface in the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfIntervalInBroadcastFrames 1.3.6.1.4.1.164.3.1.6.1.2.2.1.28
The number of received Broadcast frames, encountered by the Ethernet interface in the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfIntervalOutBroadcastFrames 1.3.6.1.4.1.164.3.1.6.1.2.2.1.29
The number of transmitted Broadcast frames, encountered by the Ethernet interface in the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfIntervalInDiscardFrames 1.3.6.1.4.1.164.3.1.6.1.2.2.1.30
The number of received Discarded frames, encountered by the Ethernet interface in the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfIntervalOutDiscardFrames 1.3.6.1.4.1.164.3.1.6.1.2.2.1.31
The number of transmitted Discarded frames, encountered by the Ethernet interface in the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfIntervalInPauseFrames 1.3.6.1.4.1.164.3.1.6.1.2.2.1.32
The number of received Pause frames, encountered by the Ethernet interface in the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfIntervalOutPauseFrames 1.3.6.1.4.1.164.3.1.6.1.2.2.1.33
The number of transmitted Pause frames, encountered by the Ethernet interface in the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfIntervalOverflowInUnicastFrames 1.3.6.1.4.1.164.3.1.6.1.2.2.1.34
The number of times the associated ethIfIntervalInUnicastFrames counter has overflowed in the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfIntervalOverflowOutUnicastFrames 1.3.6.1.4.1.164.3.1.6.1.2.2.1.35
The number of times the associated ethIfIntervalOutUnicastFrames counter has overflowed in the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfIntervalOverflowInMulticastFrames 1.3.6.1.4.1.164.3.1.6.1.2.2.1.36
The number of times the associated ethIfIntervalInMulticastFrames counter has overflowed in the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfIntervalOverflowOutMulticastFrames 1.3.6.1.4.1.164.3.1.6.1.2.2.1.37
The number of times the associated ethIfIntervalOutMulticastFrames counter has overflowed in the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfIntervalOverflowInBroadcastFrames 1.3.6.1.4.1.164.3.1.6.1.2.2.1.38
The number of times the associated ethIfIntervalInBroadcastFrames counter has overflowed in the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfIntervalOverflowOutBroadcastFrames 1.3.6.1.4.1.164.3.1.6.1.2.2.1.39
The number of times the associated ethIfIntervalOutBroadcastFrames counter has overflowed in the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfIntervalOverflowInDiscardFrames 1.3.6.1.4.1.164.3.1.6.1.2.2.1.40
The number of times the associated ethIfIntervalInDiscardFrames counter has overflowed in the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfIntervalOverflowOutDiscardFrames 1.3.6.1.4.1.164.3.1.6.1.2.2.1.41
The number of times the associated ethIfIntervalOutDiscardFrames counter has overflowed in the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfIntervalOverflowInPauseFrames 1.3.6.1.4.1.164.3.1.6.1.2.2.1.42
The number of times the associated ethIfIntervalInPauseFrames counter has overflowed in the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfIntervalOverflowOutPauseFrames 1.3.6.1.4.1.164.3.1.6.1.2.2.1.43
The number of times the associated ethIfIntervalOutPauseFrames counter has overflowed in the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethPerformanceMode 1.3.6.1.4.1.164.3.1.6.1.2.3
This object indicates whether OK or Fail statistics will be counted.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), countOK(2), countFail(3)  

ethIfPerfTable 1.3.6.1.4.1.164.3.1.6.1.2.4
The Ethernet Performance table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    EthIfPerfEntry

ethIfPerfEntry 1.3.6.1.4.1.164.3.1.6.1.2.4.1
An entry in the Ethernet Performance table.
Status: current Access: not-accessible
OBJECT-TYPE    
  EthIfPerfEntry  

ethIfPerfInOkFrames 1.3.6.1.4.1.164.3.1.6.1.2.4.1.1
The counter associated with the number of received OK frames, encountered by the Ethernet interface since ethPerformanceMode Set to countOK (2) or Reset Statistics was done.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfPerfOutOkFrames 1.3.6.1.4.1.164.3.1.6.1.2.4.1.2
The counter associated with the number of transmitted OK frames, encountered by the Ethernet interface since ethPerformanceMode Set to countOK (2) or Reset Statistics was done.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfPerfTotalCollisions 1.3.6.1.4.1.164.3.1.6.1.2.4.1.3
The counter associated with the total number of collisions of any type encountered by the Ethernet interface since ethPerformanceMode Set to countOK (2) or Reset Statistics was done
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfPerfInOkOctets 1.3.6.1.4.1.164.3.1.6.1.2.4.1.4
The counter associated with the number of received OK Octets, encountered by the Ethernet interface since ethPerformanceMode Set to countOK (2) or Reset Statistics was done.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ethIfOamCfm 1.3.6.1.4.1.164.3.1.6.1.3
OBJECT IDENTIFIER    

ethIfOamCfmEvents 1.3.6.1.4.1.164.3.1.6.1.3.0
OBJECT IDENTIFIER    

ethOamCfmDefectCondition 1.3.6.1.4.1.164.3.1.6.1.3.0.1
This trap indicates that a MEP has a persistent defect condition.
Status: current Access: read-only
NOTIFICATION-TYPE    

radMepTable 1.3.6.1.4.1.164.3.1.6.1.3.1
MEG End Point (MEP) configuration table associated with Maitenance Entity Group (MEG) End Point. MEP is a short name for an expanded ETH flow point that includes a compound ETH Segment flow termination function, which marks the end point of an ETH ME, and a compound ETH Diagnostic flow function.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RadMepEntry

radMepEntry 1.3.6.1.4.1.164.3.1.6.1.3.1.1
An entry in the table.
Status: current Access: not-accessible
OBJECT-TYPE    
  RadMepEntry  

radOamIdx1 1.3.6.1.4.1.164.3.1.6.1.3.1.1.1
This object may indicate the Bridge Index or Configuration index.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

radOamEvcIdx 1.3.6.1.4.1.164.3.1.6.1.3.1.1.2
This object indicates the Index of the EVC (Ethernet Virtual Circuit) that the MEP is associated to.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

radMepIdx 1.3.6.1.4.1.164.3.1.6.1.3.1.1.3
This object indicates the ID of the MEP being accessed.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

radMepRowStatus 1.3.6.1.4.1.164.3.1.6.1.3.1.1.4
This attribute allows to create/delete a row in this table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

radMepLocalMepId 1.3.6.1.4.1.164.3.1.6.1.3.1.1.5
This object indicates the local MEP ID.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

radMepRemoteMepId 1.3.6.1.4.1.164.3.1.6.1.3.1.1.6
This atribute is currently implemneted at radMepCcTable, that supports multicast.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

radMepOamMode 1.3.6.1.4.1.164.3.1.6.1.3.1.1.7
This object determines the OAM mode of the MEP: disabled - no CC is initiated nor responded initiate - the device initiates and responds to CC react - the device does not initiate a CC, but responds to CC.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER disabled(2), initiate(3), react(4)  

radMepContinuityVerMode 1.3.6.1.4.1.164.3.1.6.1.3.1.1.8
This object determines the OAM behavior of the MEP: disabled - no CC is done cc_based - CC is done based on incoming messages lb_based - CC is done based on loopback messages.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER disabled(2), ccBased(3), lbBased(4)  

radMepMeLevel 1.3.6.1.4.1.164.3.1.6.1.3.1.1.9
At any point in a network, ME Level is used to distinguish between OAM signals belonging to different nested MEs. Maintenance Entity Levels are defined as follows: 0,1,2 are assigned to customers 3,4 are assigned to providers 5,6,7 are assigned to operators.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..7  

radMepOamDestAddrType 1.3.6.1.4.1.164.3.1.6.1.3.1.1.10
This object determines if the OAM messages are sent to user defined unicast address, or to RAD proprietary multicast address.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER unicast(1), multicast(2)  

radMepOamDestMacAddr 1.3.6.1.4.1.164.3.1.6.1.3.1.1.11
This object determines the MAC address that OAM packets are sent to.
Status: current Access: read-create
OBJECT-TYPE    
  MacAddress  

radMepDefaultPriority 1.3.6.1.4.1.164.3.1.6.1.3.1.1.12
This object defines the priority of the OAM messages sent when no service is defined on EVC. If a service is defined, the OAM messages will get the highest service priority existing on the EVC.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..7  

radMepCcStatus 1.3.6.1.4.1.164.3.1.6.1.3.1.1.13
This object indicates the Continuity Check (CC) status.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), fail(2), ok(3), mismerge(4), unexpectedMep(5), unexpectedMeLevel(6)  

radMepOamProtocol 1.3.6.1.4.1.164.3.1.6.1.3.1.1.14
Determines whether to use proprietary OAM mechanism, or to use the standard (IEEE 802.1ag, ITU-T Y.1731).
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER proprietary(1), standard(2)  

radMepMdId 1.3.6.1.4.1.164.3.1.6.1.3.1.1.15
The index of the Maintenance Domain in the radMdTable (radMdIndex).
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

radMepMaFormat 1.3.6.1.4.1.164.3.1.6.1.3.1.1.16
The type (and thereby format) of the Maintenance Association Name.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER primaryVid(1), charString(2), unsignedInt16(3), rfc2865VpnId(4), icc(32)  

radMepMaName 1.3.6.1.4.1.164.3.1.6.1.3.1.1.17
The Short Maintenance Association name.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING Size(1..45)  

radMepSpVlanId 1.3.6.1.4.1.164.3.1.6.1.3.1.1.18
The SP (Service Provider) VLAN used when sending an OAM message.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

radMepCcInterval 1.3.6.1.4.1.164.3.1.6.1.3.1.1.19
Indicates the interval at which CCMs are sent by a MEP Valid only if radMepOamMode = initiate(4).
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER intervalInvalid(0), interval300Hz(1), interval10ms(2), interval100ms(3), interval1s(4), interval10s(5), interval1min(6), interval10min(7)  

radMepTransmitLbmDestMacAddress 1.3.6.1.4.1.164.3.1.6.1.3.1.1.20
The Target MAC Address Field to be transmitted in the Loopback Message: For unicast MAC Address this is the unicast destination MAC address. For multicast MAC Address, this variable is read-only. This address will be used if the value of radMepTransmitLbmDestIsMepId is no (2). 802.1ag clause 12.14.7.3.2:b.
Status: current Access: read-create
OBJECT-TYPE    
  MacAddress  

radMepTransmitLbmDestMepId 1.3.6.1.4.1.164.3.1.6.1.3.1.1.21
The MEPID of another MEP in the same MA to which the LBM is to be sent. This address will be used if the value of radMepTransmitLbmDestIsMepId is yes (3). 802.1ag clause 12.14.7.3.2:b.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

radMepTransmitLbmDestIsMepId 1.3.6.1.4.1.164.3.1.6.1.3.1.1.22
yes (3) indicates that MEPID of the target MEP is used for loopback transmission. no (2) indicates that unicast destination MAC address of the target MEP is used. 802.1ag clause 12.14.7.3.2:b.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

radMepTransmitLbmMassages 1.3.6.1.4.1.164.3.1.6.1.3.1.1.23
The number of Loopback messages to be transmitted.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 1..1024  

radMepTransmitLbmVlanPriority 1.3.6.1.4.1.164.3.1.6.1.3.1.1.24
The priority to be used in the VLAN tag, if present, in the transmitted frame. The default value is CCM priority. 802.1ag clause 12.14.7.3.2:e
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..7  

radMepTransmitLbmVlanDropEnable 1.3.6.1.4.1.164.3.1.6.1.3.1.1.25
Drop Enable bit to be used in the VLAN tag, if present, in the transmitted frame. 802.1ag clause 12.14.7.3.2:e
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

radMepLbrIn 1.3.6.1.4.1.164.3.1.6.1.3.1.1.26
Total number of valid, in-order Loopback Replies received.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

radMepLbrInOutOfOrder 1.3.6.1.4.1.164.3.1.6.1.3.1.1.27
The total number of valid, out-of-order Loopback Replies received.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

radMepLbmOut 1.3.6.1.4.1.164.3.1.6.1.3.1.1.28
Total number of Loopback Messages transmitted.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

radMepTransmitLtmTargetMacAddress 1.3.6.1.4.1.164.3.1.6.1.3.1.1.29
The Target MAC Address Field to be transmitted in the Link Trace Message: A unicast destination MAC address. This address will be used if the value of radMepTransmitLtmTargetIsMepId is no (2). 802.1ag clause 12.14.7.4.2:c.
Status: current Access: read-create
OBJECT-TYPE    
  MacAddress  

radMepTransmitLtmTargetMepId 1.3.6.1.4.1.164.3.1.6.1.3.1.1.30
The MEPID of another MEP in the same MA to which LTM is to be transmitted. This address will be used if the value of radMepTransmitLtmTargetIsMepId is yes (3). 802.1ag clause 12.14.7.4.2:c.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

radMepTransmitLtmTargetIsMepId 1.3.6.1.4.1.164.3.1.6.1.3.1.1.31
yes (3) indicates that MEPID of the target MEP is used for Linktrace transmission. no (2) indicates that unicast destination MAC address of the target MEP is used. 802.1ag clause 12.14.7.4.2:c.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

radMepTransmitLtmTtl 1.3.6.1.4.1.164.3.1.6.1.3.1.1.32
The LTM TTL field. Default value, if not specified, is 64. The TTL field indicates the number of hops remaining to the LTM. Decremented by 1 each Linktrace Responder that handles the LTM. The value received in the LTM is returned in the LTR. If 0 on input, the LTM is not transmitted to the next hop. 802.1ag clause 12.14.7.4.2:b and 21.8.4.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

radMepTransmitLtmActivationCmd 1.3.6.1.4.1.164.3.1.6.1.3.1.1.33
Activation command for starting Loop Trace. Set will be always to 'on' value. After operation was finished, Agent will turn the value to 'off'.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER off(2), on(3)  

ethOamService 1.3.6.1.4.1.164.3.1.6.1.3.2
OBJECT IDENTIFIER    

ethOamServiceTable 1.3.6.1.4.1.164.3.1.6.1.3.2.1
Service configuration table associated with Services running on a MEP.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    EthOamServiceEntry

ethOamServiceEntry 1.3.6.1.4.1.164.3.1.6.1.3.2.1.1
An entry in the table.
Status: current Access: not-accessible
OBJECT-TYPE    
  EthOamServiceEntry  

ethOamServiceIdx 1.3.6.1.4.1.164.3.1.6.1.3.2.1.1.1
This object indicates the Index of the service being accessed.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

ethOamServiceRowStatus 1.3.6.1.4.1.164.3.1.6.1.3.2.1.1.2
This attribute allows to create/delete a row in this table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

ethOamServicePriority 1.3.6.1.4.1.164.3.1.6.1.3.2.1.1.3
This object determines the priority of the service. It is sent as P bits in an OAM message originated by this service.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..7  

ethOamServicePmEnable 1.3.6.1.4.1.164.3.1.6.1.3.2.1.1.4
This object determines PM (Performance Monitoring) shall be enabled or not for the service.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER disable(2), enable(3)  

ethOamServiceFrameLossRatioThresh 1.3.6.1.4.1.164.3.1.6.1.3.2.1.1.5
This object determines the Frame Loss ratio threshold in exponent of 1/10. That is, a value of 4 means that the threshold is 1E-4.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 3..10  

ethOamServiceDelayThresh 1.3.6.1.4.1.164.3.1.6.1.3.2.1.1.6
This object determines the delay threshold defined for this service, in measurement unit of 0.1 msec.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..50000  

ethOamServiceDelayVarThresh 1.3.6.1.4.1.164.3.1.6.1.3.2.1.1.7
This object determines the delay variation threshold defined for this service, in measurement unit of 0.1 msec.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..50000  

ethOamServiceUnavailRatioThresh 1.3.6.1.4.1.164.3.1.6.1.3.2.1.1.8
This object determines the Unavailability ratio threshold in exponent of 1/10. That is, a value of 4 means that the threshold is 1E-4.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 3..10  

ethOamServiceTxFrames 1.3.6.1.4.1.164.3.1.6.1.3.2.1.1.9
Counts the number of frames trnasmitted by since the time the service is up.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ethOamServiceOverflowTxFrames 1.3.6.1.4.1.164.3.1.6.1.3.2.1.1.10
The number of times the associated ethOamServiceTxFrames counter has overflowed.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ethOamServiceFrameLoss 1.3.6.1.4.1.164.3.1.6.1.3.2.1.1.11
Counts the number of frames lost since the time the service is up.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ethOamServiceOverflowFrameLoss 1.3.6.1.4.1.164.3.1.6.1.3.2.1.1.12
The number of times the associated ethOamServiceFrameLoss counter has overflowed.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ethOamServiceFrameLossRatio 1.3.6.1.4.1.164.3.1.6.1.3.2.1.1.13
Indicates the ratio of the lost frames since the time the service is up. The value is the ratio multiplied by 1E10. 0xFFFFFFFF will be returned for ratio greater than 4/10 (40%).
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

ethOamServiceElapsedTime 1.3.6.1.4.1.164.3.1.6.1.3.2.1.1.14
Indicates the time elapsed in seconds since the time the service is up.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ethOamServiceUnavailSec 1.3.6.1.4.1.164.3.1.6.1.3.2.1.1.15
Indicates the number of unavailable seconds since the time the service is up.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ethOamServiceUnavailRatio 1.3.6.1.4.1.164.3.1.6.1.3.2.1.1.16
Indicates the ratio of the unavailable seconds since the time the service is up. The value is the ratio multiplied by 1E10. 0xFFFFFFFF will be returned for ratio greater than 4/10 (40%).
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

ethOamServiceFramesAboveDelay 1.3.6.1.4.1.164.3.1.6.1.3.2.1.1.17
Indicates the number of frames arrived with delay greater than the delay threshold.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ethOamServiceOverflowFramesAboveDelay 1.3.6.1.4.1.164.3.1.6.1.3.2.1.1.18
Indicates the number of times the associated ethOamServiceFramesAboveDelay counter has overflowed.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ethOamServiceFramesAboveDelayVar 1.3.6.1.4.1.164.3.1.6.1.3.2.1.1.19
Indicates the number of frames arrived with delay variation greater than the delay variation threshold.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ethOamServiceOverflowFramesAboveDelayVar 1.3.6.1.4.1.164.3.1.6.1.3.2.1.1.20
Indicates the number of times the associated ethOamServiceFramesAboveDelayVar counter has overflowed.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ethOamSvcCurrentStatTable 1.3.6.1.4.1.164.3.1.6.1.3.2.2
Service Current Statistics Table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    EthOamSvcCurrentStatEntry

ethOamSvcCurrentStatEntry 1.3.6.1.4.1.164.3.1.6.1.3.2.2.1
Current Statistics per service
Status: current Access: not-accessible
OBJECT-TYPE    
  EthOamSvcCurrentStatEntry  

ethOamSvcCurrFramesAboveDelayThresh 1.3.6.1.4.1.164.3.1.6.1.3.2.2.1.1
Number of frames that arrived in the current interval at a delay greater than the threshold value defined for the service.
Status: current Access: read-only
OBJECT-TYPE    
  PerfCurrentCount  

ethOamSvcCurrFramesBelowDelayThresh 1.3.6.1.4.1.164.3.1.6.1.3.2.2.1.2
Number of frames that arrived in the current interval at a delay lower than or equal to the threshold value defined for the service.
Status: current Access: read-only
OBJECT-TYPE    
  PerfCurrentCount  

ethOamSvcCurrFramesAboveDVarThresh 1.3.6.1.4.1.164.3.1.6.1.3.2.2.1.3
Number of frames that arrived in the current interval at a delay variation greater than the threshold value defined for the service.
Status: current Access: read-only
OBJECT-TYPE    
  PerfCurrentCount  

ethOamSvcCurrFramesBelowDVarThresh 1.3.6.1.4.1.164.3.1.6.1.3.2.2.1.4
Number of frames that arrived in the current interval at a delay variation lower than or equal to the threshold value defined for the service.
Status: current Access: read-only
OBJECT-TYPE    
  PerfCurrentCount  

ethOamSvcCurrFramesTxCounter 1.3.6.1.4.1.164.3.1.6.1.3.2.2.1.5
Number of trnasmitted frames in the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfCurrentCount  

ethOamSvcCurrFramesLossCounter 1.3.6.1.4.1.164.3.1.6.1.3.2.2.1.6
Number of lost frames in the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfCurrentCount  

ethOamSvcCurrMinRoundTripDelay 1.3.6.1.4.1.164.3.1.6.1.3.2.2.1.7
The mininal value of round trip delay in the current interval. Values units are of 0.1 msec.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

ethOamSvcCurrMaxRoundTripDelay 1.3.6.1.4.1.164.3.1.6.1.3.2.2.1.8
The maximum value of round trip delay in the current interval. Values units are of 0.1 msec.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

ethOamSvcCurrAvgRoundTripDelay 1.3.6.1.4.1.164.3.1.6.1.3.2.2.1.9
The average round trip delay in the current interval. Values units are of 0.1 msec.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

ethOamSvcCurrMaxRoundTripDVar 1.3.6.1.4.1.164.3.1.6.1.3.2.2.1.10
The maximum value of round trip delay variation in the current interval. Values units are of 0.1 msec.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

ethOamSvcCurrAvgRoundTripDVar 1.3.6.1.4.1.164.3.1.6.1.3.2.2.1.11
The average round trip delay variation in the current interval. Values units are of 0.1 msec.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

ethOamSvcCurrElapsedTime 1.3.6.1.4.1.164.3.1.6.1.3.2.2.1.12
The number of seconds that have elapsed since the beginning of the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..899  

ethOamSvcCurrUnavailSec 1.3.6.1.4.1.164.3.1.6.1.3.2.2.1.13
The number of seconds that the service was unavailable in the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfCurrentCount  

ethOamSvcIntervalTable 1.3.6.1.4.1.164.3.1.6.1.3.2.3
Service Interval Statistics Table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    EthOamSvcIntervalEntry

ethOamSvcIntervalEntry 1.3.6.1.4.1.164.3.1.6.1.3.2.3.1
Interval Statistics per service
Status: current Access: not-accessible
OBJECT-TYPE    
  EthOamSvcIntervalEntry  

ethOamSvcIntervalNum 1.3.6.1.4.1.164.3.1.6.1.3.2.3.1.1
The Interval index, which is actualy the Interval number, where 1 is the most recently completed 15 minute interval, and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals exist).
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..96  

ethOamSvcIntervalFramesAboveDelayThresh 1.3.6.1.4.1.164.3.1.6.1.3.2.3.1.2
Number of frames that arrived in a delay greater than the threshold value defined for the service in the selected interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfIntervalCount  

ethOamSvcIntervalFramesBelowDelayThresh 1.3.6.1.4.1.164.3.1.6.1.3.2.3.1.3
Number of frames that arrived in a delay lower than the threshold value defined for the service in the selected interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfIntervalCount  

ethOamSvcIntervalFramesAboveDVarThresh 1.3.6.1.4.1.164.3.1.6.1.3.2.3.1.4
Number of frames that arrived in a delay variation greater than the threshold value defined for the service in the selected interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfIntervalCount  

ethOamSvcIntervalFramesBelowDVarThresh 1.3.6.1.4.1.164.3.1.6.1.3.2.3.1.5
Number of frames that arrived in a delay variation lower than the threshold value defined for the service in the selected interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfIntervalCount  

ethOamSvcIntervalFramesTxCounter 1.3.6.1.4.1.164.3.1.6.1.3.2.3.1.6
Number of trnasmitted frames in the selected interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfIntervalCount  

ethOamSvcIntervalFramesLossCounter 1.3.6.1.4.1.164.3.1.6.1.3.2.3.1.7
Number of lost frames in the selected interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfIntervalCount  

ethOamSvcIntervalMinRoundTripDelay 1.3.6.1.4.1.164.3.1.6.1.3.2.3.1.8
The mininal value of round trip delay in the selected interval. Values units are of 0.1 msec.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

ethOamSvcIntervalMaxRoundTripDelay 1.3.6.1.4.1.164.3.1.6.1.3.2.3.1.9
The maximum value of round trip delay in the selected interval. Values units are of 0.1 msec.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

ethOamSvcIntervalAvgRoundTripDelay 1.3.6.1.4.1.164.3.1.6.1.3.2.3.1.10
The average round trip delay in the selected interval. Values units are of 0.1 msec.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

ethOamSvcIntervalMaxRoundTripDVar 1.3.6.1.4.1.164.3.1.6.1.3.2.3.1.11
The maximum value of round trip delay variation in the selected interval. Values units are of 0.1 msec.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

ethOamSvcIntervalAvgRoundTripDVar 1.3.6.1.4.1.164.3.1.6.1.3.2.3.1.12
The average round trip delay variation in the selected interval. Values units are of 0.1 msec.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

ethOamSvcIntervalUnavailSec 1.3.6.1.4.1.164.3.1.6.1.3.2.3.1.13
The number of seconds that the service was unavailable in the selected interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfIntervalCount  

ethOamSvcTotalTable 1.3.6.1.4.1.164.3.1.6.1.3.2.4
ETH OAM Service Total (24H) Statistics Table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    EthOamSvcTotalEntry

ethOamSvcTotalEntry 1.3.6.1.4.1.164.3.1.6.1.3.2.4.1
Total Statistics per service
Status: current Access: not-accessible
OBJECT-TYPE    
  EthOamSvcTotalEntry  

ethOamSvcTotalFramesAboveDelayThresh 1.3.6.1.4.1.164.3.1.6.1.3.2.4.1.1
Number of frames that arrived in a delay greater than the threshold value defined for the service in the last 24H.
Status: current Access: read-only
OBJECT-TYPE    
  PerfTotalCount  

ethOamSvcTotalFramesBelowDelayThresh 1.3.6.1.4.1.164.3.1.6.1.3.2.4.1.2
Number of frames that arrived in a delay lower than the threshold value defined for the service in the last 24H.
Status: current Access: read-only
OBJECT-TYPE    
  PerfTotalCount  

ethOamSvcTotalFramesAboveDVarThresh 1.3.6.1.4.1.164.3.1.6.1.3.2.4.1.3
Number of frames that arrived in a delay variation greater than the threshold value defined for the service in the last 24H.
Status: current Access: read-only
OBJECT-TYPE    
  PerfTotalCount  

ethOamSvcTotalFramesBelowDVarThresh 1.3.6.1.4.1.164.3.1.6.1.3.2.4.1.4
Number of frames that arrived in a delay variation lower than the threshold value defined for the service in the last 24H.
Status: current Access: read-only
OBJECT-TYPE    
  PerfTotalCount  

ethOamSvcTotalFramesTxCounter 1.3.6.1.4.1.164.3.1.6.1.3.2.4.1.5
Number of trnasmitted frames in the last 24H.
Status: current Access: read-only
OBJECT-TYPE    
  PerfTotalCount  

ethOamSvcTotalFramesLossCounter 1.3.6.1.4.1.164.3.1.6.1.3.2.4.1.6
Number of lost frames in the last 24H.
Status: current Access: read-only
OBJECT-TYPE    
  PerfTotalCount  

ethOamSvcTotalMinRoundTripDelay 1.3.6.1.4.1.164.3.1.6.1.3.2.4.1.7
The mininal value of round trip delay in the last 24H. Values units are of 0.1 msec.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

ethOamSvcTotalMaxRoundTripDelay 1.3.6.1.4.1.164.3.1.6.1.3.2.4.1.8
The maximum value of round trip delay in the last 24H. Values units are of 0.1 msec.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

ethOamSvcTotalAvgRoundTripDelay 1.3.6.1.4.1.164.3.1.6.1.3.2.4.1.9
The average round trip delay in the last 24H. Values units are of 0.1 msec.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

ethOamSvcTotalMaxRoundTripDVar 1.3.6.1.4.1.164.3.1.6.1.3.2.4.1.10
The maximum value of round trip delay variation in the last 24H. Values units are of 0.1 msec.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

ethOamSvcTotalAvgRoundTripDVar 1.3.6.1.4.1.164.3.1.6.1.3.2.4.1.11
The average round trip delay variation in the last 24H. Values units are of 0.1 msec.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

ethOamSvcTotalUnavailSec 1.3.6.1.4.1.164.3.1.6.1.3.2.4.1.12
The number of seconds that the service was unavailable in the last 24H.
Status: current Access: read-only
OBJECT-TYPE    
  PerfTotalCount  

radMdTable 1.3.6.1.4.1.164.3.1.6.1.3.3
The MaintenanceDomain table. Each row in the table represents a different maintenance domain. A Maintenance domain is described in 802.1ag (3.22) as the network or the part of the network for which faults in connectivity are to be managed. The boundary of a Maintenance Domain is defined by a set of DSAPs, each of which can become a point of connectivity to a service instance.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RadMdEntry

radMdEntry 1.3.6.1.4.1.164.3.1.6.1.3.3.1
The Maintenance Domain table entry. This entry is not lost upon reboot. It is backed up by stable storage
Status: current Access: not-accessible
OBJECT-TYPE    
  RadMdEntry  

radMdIndex 1.3.6.1.4.1.164.3.1.6.1.3.3.1.1
The index to the maintenance domain table.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

radMdFormat 1.3.6.1.4.1.164.3.1.6.1.3.3.1.2
The type (and thereby format) of the Maintenance Domain Name.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER none(1), dnsLikeName(2), macAddressAndUint(3), charString(4)  

radMdName 1.3.6.1.4.1.164.3.1.6.1.3.3.1.3
The Maintenance Domain name. The type/format of this object is determined by the value of the radMdNameType object. Each Maintenance Domain has unique name amongst all those used or available to a service provider or operator. It facilitates easy identification of administrative responsibility for each Maintenance Domain.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING Size(1..43)  

radMdRowStatus 1.3.6.1.4.1.164.3.1.6.1.3.3.1.4
This attribute allows to create/delete a row in this table. The writable columns in a row can not be changed if the row is active. All columns must have a valid value before a row can be activated.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

radMepLtrTable 1.3.6.1.4.1.164.3.1.6.1.3.4
This table contains a list of Linktrace replies received by a specific MEP in response to a linktrace message.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RadMepLtrEntry

radMepLtrEntry 1.3.6.1.4.1.164.3.1.6.1.3.4.1
The LinktraceReply table entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  RadMepLtrEntry  

radMepLtrReceiveOrder 1.3.6.1.4.1.164.3.1.6.1.3.4.1.1
An index to distinguish among multiple LTRs with the same LTR Transaction Identifier field value. radMepLtrReceiveOrder are assigned sequentially from 1, in the order that the Linktrace Initiator received the LTRs.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

radMepLtrTtl 1.3.6.1.4.1.164.3.1.6.1.3.4.1.2
TTL field value for a returned LTR.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..255  

radMepLtrMacAddr 1.3.6.1.4.1.164.3.1.6.1.3.4.1.3
The MAC address in the header of the returned LTR.
Status: current Access: read-only
OBJECT-TYPE    
  MacAddress  

radMepLtrRelay 1.3.6.1.4.1.164.3.1.6.1.3.4.1.4
The value returned in the Relay Action field: rlyHit - the LTM reached an MP whose MAC address matches the target MAC address. rlyFdb - the Egress Port was determined by consulting the Filtering Database. rlyMpdb - the Egress Port was determined by consulting the MIP CCM Database. 802.1ag clauses 12.14.7.5.3:g and 20.36.2.5
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER rlyHit(1), rlyFdb(2), rlyMpdb(3)  

radMepLtrIngress 1.3.6.1.4.1.164.3.1.6.1.3.4.1.5
The value returned in the Ingress Action Field of the LTM. ingNoTlv - no Reply Ingress TLV was returned in the LTM. ingOK - the target data frame would be passed through to the MAC Relay Entity. ingDown - the Bridge Port's MAC_Operational parameter is false. ingBlocked - the target data frame would not be forwarded if received on this port. ingVid - the ingress port is not in the members of the LTM's VID, and ingress filtering is enabled, so the target data frame would be filtered by the ingress filtering. 802.1ag clauses 12.14.7.5.3:k and 20.36.2.6
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER ingNoTlv(1), ingOk(2), ingDown(3), ingBlocked(4), ingVid(5)  

radMepLtrIngressPortIdSubtype 1.3.6.1.4.1.164.3.1.6.1.3.4.1.6
The format of the Ingress Port ID. If the radMepLtrIngress object contains the value egrNoTlv(1), then the contents of this object are meaningless. 802.1ag clauses 12.14.7.5.3:m and 20.36.2.8
Status: current Access: read-only
OBJECT-TYPE    
  LldpPortIdSubtype  

radMepLtrIngressPortId 1.3.6.1.4.1.164.3.1.6.1.3.4.1.7
Ingress Port ID. This is an alpha-numeric string that contains a specific identifier for the port. The format of this object is determined by the value of the radMepLtrIngressPortIdSubtype object. If the radMepLtrIngress object contains the value ingNoTlv(1), then the contents of this object are meaningless. 802.1ag clauses 12.14.7.5.3:n and 20.36.2.9
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1..255)  

radMepLtrEgress 1.3.6.1.4.1.164.3.1.6.1.3.4.1.8
The value returned in the Egress Action Field of the LTM. The value egrNoTlv(1) indicates that no Reply Egress TLV was returned in the LTM. 802.1ag clauses 12.14.7.5.3:o and 20.36.2.10
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER egrNoTlv(1), egrOK(2), egrDown(3), egrBlocked(4), egrVid(5)  

radMepLtrEgressPortIdSubtype 1.3.6.1.4.1.164.3.1.6.1.3.4.1.9
The format of the egress Port ID. If the radMepLtrEgress object contains the value egrNoTlv(1), then the contents of this object are meaningless. 802.1ag clauses 12.14.7.5.3:q and 20.36.2.12
Status: current Access: read-only
OBJECT-TYPE    
  LldpPortIdSubtype  

radMepLtrEgressPortId 1.3.6.1.4.1.164.3.1.6.1.3.4.1.10
Egress Port ID. The format of this object is determined by the value of the radMepLtrEgressPortIdSubtype object. If the radMepLtrEgress object contains the value egrNoTlv(1), then the contents of this object are meaningless. 802.1ag clauses 12.14.7.5.3:r and 20.36.2.13
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1..255)  

radMepCcStatusTable 1.3.6.1.4.1.164.3.1.6.1.3.5
This table contains a list of CC Status received by a specific MEP from different Remote MEPs.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RadMepCcStatusEntry

radMepCcStatusEntry 1.3.6.1.4.1.164.3.1.6.1.3.5.1
An entry in the CC Status Table.
Status: current Access: not-accessible
OBJECT-TYPE    
  RadMepCcStatusEntry  

radMepRemoteMepIdx 1.3.6.1.4.1.164.3.1.6.1.3.5.1.1
This is a running index for arriving CC messages (from different Remote MEPs) for a specific MEP ID.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

radMepCcStatusRemMepId 1.3.6.1.4.1.164.3.1.6.1.3.5.1.2
This attribute indicates the Remote MEP ID from which the CC messages has arrived.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

radMepCcStat 1.3.6.1.4.1.164.3.1.6.1.3.5.1.3
This object indicates the Continuity Check (CC) status (ITU-T Y.1731, Appendix I): mismerge - A MEP detects a Mismerge condition when a CCM frame arrives with the correct MEG level, but incorrect MEG ID. unexpectedMep -A MEP detects an Unexpected MEP condition when a CCM frame arrives with the correct MEG level, the correct MEG ID, but an unexpected MEP ID, which includes the MEP's own MEP ID. unexpectedMeLevel - A MEP detects an Unexpected MEG Level condition when a CCM frame arrives with incorrect MEG Level. Incorrect MEG Level is less than the MEP's own MEG level. unexpectedPeriod - A MEP detects an Unexpected Period condition when a CCM frame arrives with a correct MEG level. a correct MEG ID, a correct MEP ID, but with the Period field value different from the MEP's own CCM transmission period. rdi - A MEP detects RDI when it receives a CCM frame with the RDI field set.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), fail(2), ok(3), mismerge(4), unexpectedMep(5), unexpectedMeLevel(6), unexpectedPeriod(7), rdi(8)  

radMepCcStatusMacAddr 1.3.6.1.4.1.164.3.1.6.1.3.5.1.4
This object indicates the MAC Address in the CC Status message received.
Status: current Access: read-only
OBJECT-TYPE    
  MacAddress  

ethOamStdEtherType 1.3.6.1.4.1.164.3.1.6.1.3.6
The Standard Ether Type in an OAM message. This object will be RW until a formal value will be issued for standard Ethernet Type. When such Standard will exist, this object will be supported RO to reflect the Standard value.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

ethOamStdMacAddress 1.3.6.1.4.1.164.3.1.6.1.3.7
The Standard MAC Address in an OAM message. This object will be RW until a formal value will be issued for standard MAC Address. When such Standard will exist, this object will be supported RO to reflect the Standard value.
Status: current Access: read-write
OBJECT-TYPE    
  MacAddress  

dot1agXCfmMdTable 1.3.6.1.4.1.164.3.1.6.1.3.8
The Maintenance Domain table. Each row in the table represents a different maintenance association.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Dot1agXCfmMdEntry

dot1agXCfmMdEntry 1.3.6.1.4.1.164.3.1.6.1.3.8.1
The Maintenance Domain table entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  Dot1agXCfmMdEntry  

dot1agXCfmMdProtocol 1.3.6.1.4.1.164.3.1.6.1.3.8.1.1
.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER preStandard(1), standard(2)  

dot1agXCfmMepTable 1.3.6.1.4.1.164.3.1.6.1.3.9
The Maintenance Association End Point (MEP) table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Dot1agXCfmMepEntry

dot1agXCfmMepEntry 1.3.6.1.4.1.164.3.1.6.1.3.9.1
The MEP table entry
Status: current Access: not-accessible
OBJECT-TYPE    
  Dot1agXCfmMepEntry  

dot1agXCfmMepContinuityVerMode 1.3.6.1.4.1.164.3.1.6.1.3.9.1.1
This object determines the OAM behavior of the MEP: disabled - no Continuity Verification is done cc_based - Continuity Verification is done based on incoming CC messages lb_based - Continuity Verification is done based on loopback messages.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER disabled(2), ccBased(3), lbBased(4)  

dot1agXCfmMepDestAddrType 1.3.6.1.4.1.164.3.1.6.1.3.9.1.2
This object determines if the OAM messages are sent to user defined unicast address, or to RAD proprietary multicast address.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER unicast(1), multicast(2)  

dot1agXCfmMepDestMacAddr 1.3.6.1.4.1.164.3.1.6.1.3.9.1.3
This object determines the MAC address that OAM packets are sent to.
Status: current Access: read-create
OBJECT-TYPE    
  MacAddress  

dot1agXCfmMepDbTable 1.3.6.1.4.1.164.3.1.6.1.3.10
The MEP DB table
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Dot1agXCfmMepDbEntry

dot1agXCfmMepDbEntry 1.3.6.1.4.1.164.3.1.6.1.3.10.1
The MEP Database table entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  Dot1agXCfmMepDbEntry  

dot1agXCfmMepCcStat 1.3.6.1.4.1.164.3.1.6.1.3.10.1.1
This object indicates the Continuity Check (CC) status (ITU-T Y.1731, Appendix I): mismerge - A MEP detects a Mismerge condition when a CCM frame arrives with the correct MEG level, but incorrect MEG ID. unexpectedMep -A MEP detects an Unexpected MEP condition when a CCM frame arrives with the correct MEG level, the correct MEG ID, but an unexpected MEP ID, which includes the MEP's own MEP ID. unexpectedMeLevel - A MEP detects an Unexpected MEG Level condition when a CCM frame arrives with incorrect MEG Level. Incorrect MEG Level is less than the MEP's own MEG level. unexpectedPeriod - A MEP detects an Unexpected Period condition when a CCM frame arrives with a correct MEG level. a correct MEG ID, a correct MEP ID, but with the Period field value different from the MEP's own CCM transmission period. rdi - A MEP detects RDI when it receives a CCM frame with the RDI field set.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), fail(2), ok(3), mismerge(4), unexpectedMep(5), unexpectedMeLevel(6), unexpectedPeriod(7), rdi(8)  

ethIfRing 1.3.6.1.4.1.164.3.1.6.1.4
OBJECT IDENTIFIER    

ethIfRingEvents 1.3.6.1.4.1.164.3.1.6.1.4.0
OBJECT IDENTIFIER    

ethIfRingTable 1.3.6.1.4.1.164.3.1.6.1.4.1
Ethernet Ring Table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    EthIfRingEntry

ethIfRingEntry 1.3.6.1.4.1.164.3.1.6.1.4.1.1
An entry in the table.
Status: current Access: not-accessible
OBJECT-TYPE    
  EthIfRingEntry  

ethIfRingIdx 1.3.6.1.4.1.164.3.1.6.1.4.1.1.1
This object is an Index that can indicate Slot, Ring, Cnfg etc., according to the device used. When NA, 1 will be used.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

ethIfRingAdminStatus 1.3.6.1.4.1.164.3.1.6.1.4.1.1.2
This object denotes the Ethernet Ring administrative status.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER down(2), up(3)  

ethIfRingPorts 1.3.6.1.4.1.164.3.1.6.1.4.1.1.3
The set of ports which are assigned to be ring members. The default value of this object is a string of zeros.
Status: current Access: read-write
OBJECT-TYPE    
  PortList  

ethIfRingOperStatus 1.3.6.1.4.1.164.3.1.6.1.4.1.1.4
This object indicates the Ethernet Ring operational status.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), open(2), close(3)  

ethIfRingKeepAliveInterval 1.3.6.1.4.1.164.3.1.6.1.4.1.1.5
This parameter indicates the period of time (in msec.) between two consequent Keep Alive messages.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

ethIfRingKeepAliveThresh 1.3.6.1.4.1.164.3.1.6.1.4.1.1.6
This parameter indicates the maximum number of missed Keep Alive answer messages acceptable, after which link status will be failed.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

ethIfRingKeepAliveVlanId 1.3.6.1.4.1.164.3.1.6.1.4.1.1.7
Dedicated VLAN ID for keep alive messages.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

ethIfRingMultiCastVlanId 1.3.6.1.4.1.164.3.1.6.1.4.1.1.8
Dedicated VLAN ID for multicast messages.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

ethIfRingRowStatus 1.3.6.1.4.1.164.3.1.6.1.4.1.1.9
Implement creation/deletion of rings in the device.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER active(1), createAndGo(4), destroy(6)  

ethIfRingStatusChange 1.3.6.1.4.1.164.3.1.6.1.4.0.1
This trap indicates that the status of the Ethernet Ring has been changed.
Status: current Access: read-write
NOTIFICATION-TYPE    

ethIfStorming 1.3.6.1.4.1.164.3.1.6.1.5
OBJECT IDENTIFIER    

ethIfStormTable 1.3.6.1.4.1.164.3.1.6.1.5.1
Ethernet Storming Table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    EthIfStormEntry

ethIfStormEntry 1.3.6.1.4.1.164.3.1.6.1.5.1.1
An entry in the table.
Status: current Access: not-accessible
OBJECT-TYPE    
  EthIfStormEntry  

ethIfStormCnfgIdx 1.3.6.1.4.1.164.3.1.6.1.5.1.1.1
This attribute indicates the Idx of the Cnfg(1..255) being accessed ; Idx of 255 relates to the TmpCnfg.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 1..255  

ethIfStormIfIdx 1.3.6.1.4.1.164.3.1.6.1.5.1.1.2
A unique index of the ethernet interface/port.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

ethIfStormDirection 1.3.6.1.4.1.164.3.1.6.1.5.1.1.3
This object indicates the port's Storm Direction.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER all(1), ingress(2), egress(3)  

ethIfStormPacketType 1.3.6.1.4.1.164.3.1.6.1.5.1.1.4
Packet Type on which Storming operations will be performed.
Status: current Access: not-accessible
OBJECT-TYPE    
  BITS unknownUnicast(0), broadcast(1), multicast(2)  

ethIfStormCtrlEnable 1.3.6.1.4.1.164.3.1.6.1.5.1.1.5
This object indicates if the Storm Controling is Enabled or Disabled for the relevant entry.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(2), enable(3)  

ethIfStormMaxRate 1.3.6.1.4.1.164.3.1.6.1.5.1.1.6
This object indicates the Maximum Rate at which Storming packets are forwarded, in Kbps.For some devices the units are PPS(Packets Per Second ) or kilobytes per second.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

ethIfOamEfm 1.3.6.1.4.1.164.3.1.6.1.6
OBJECT IDENTIFIER    

dot3OamEvents 1.3.6.1.4.1.164.3.1.6.1.6.0
OBJECT IDENTIFIER    

dot3OamOperStatusChange 1.3.6.1.4.1.164.3.1.6.1.6.0.1
This trap is sent when OAM EFM Link goes Up or Down. Up - is considered when dot3OamOperStatus value changes to operational(9) from any other value. Down - is considered when dot3OamOperStatus value changes from operational(9) to any other value.
Status: current Access: read-write
NOTIFICATION-TYPE    

dot3OamPeerEvent 1.3.6.1.4.1.164.3.1.6.1.6.0.2
This trap is sent when value of dot3OamXPeerState changes from any value to one of the following values: linkFault, dyingGasp, criticalEvent. This trap has no recovery (clearing value).
Status: current Access: read-write
NOTIFICATION-TYPE    

dot3OamDescrTable 1.3.6.1.4.1.164.3.1.6.1.6.1
This table supports definitions of Descriptors (profiles) of OAM EFM Links.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Dot3OamDescrEntry

dot3OamDescrEntry 1.3.6.1.4.1.164.3.1.6.1.6.1.1
Each entry corresponds to a single OAM EFM Descriptor (profile). Each Descriptor contains a set of OAM EFM Link configuration parameters. The configuration parameters are applied to the OAM EFM Links referencing this Descriptor (see dot3OamXDescrId object). Descriptors may be created/deleted using the row creation/deletion mechanism via dot3OamDescrRowStatus. If an active entry is referenced in dot3OamXDescrId, the entry MUST remain active until all references are removed.
Status: current Access: not-accessible
OBJECT-TYPE    
  Dot3OamDescrEntry  

dot3OamDescrId 1.3.6.1.4.1.164.3.1.6.1.6.1.1.1
This object is the unique index associated with this Descriptor (profile). Entries in this table are referenced via the object dot3OamXDescrId in dot3OamXEntry.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 1..4294967295  

dot3OamDescrRowStatus 1.3.6.1.4.1.164.3.1.6.1.6.1.1.2
This object controls creation/deletion of the associated entry in this table per the semantics of RowStatus. If an active entry is referenced in dot3OamXDescrId, the entry MUST remain active until all references are removed.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

dot3OamDescrMode 1.3.6.1.4.1.164.3.1.6.1.6.1.1.3
This object controls the mode of OAM operation for an Ethernet-like interface referencing this Descriptor. OAM on Ethernet interfaces may be in 'active' mode or 'passive' mode. These two modes differ in that active mode provides additional capabilities to initiate monitoring activities with the remote OAM peer entity, while passive mode generally waits for the peer to initiate OAM actions with it. As an example, an active OAM entity can put the remote OAM entity in a loopback state, where a passive OAM entity cannot.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER passive(1), active(2)  

dot3OamDescrLbRxOperation 1.3.6.1.4.1.164.3.1.6.1.6.1.1.4
Since OAM loopback is a disruptive operation (user traffic does not pass), this object provides a mechanism to provide control: whether received OAM loopback commands are processed or ignored, for the OAM Link referencing this Descriptor. When the value is ignore(1), received loopback commands are ignored. When the value is process(2), received loopback commands are processed. The default value is to ignore loopback commands (ignore(1)).
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER ignore(1), process(2)  

dot3OamDescrRateLimit 1.3.6.1.4.1.164.3.1.6.1.6.1.1.5
This object defines how many OAM frames can be sent per second (maximum) for an OAM EFM Link referencing this Descriptor.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

dot3OamXTable 1.3.6.1.4.1.164.3.1.6.1.6.2
This table is an extension of dot3OamTable of standard DOT3-OAM-MIB.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Dot3OamXEntry

dot3OamXEntry 1.3.6.1.4.1.164.3.1.6.1.6.2.1
An entry in dot3OamXTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  Dot3OamXEntry  

dot3OamXDescrId 1.3.6.1.4.1.164.3.1.6.1.6.2.1.1
This object points to an entry of dot3OamDescrTable (dot3OamDescrId), which defines part of the configuration parameters for this OAM EFM Link. As long as one of the OAM EFM Links refers an entry in the dot3OamDescrTable, this entry cannot be removed. When an OAM EFM Link supports this object (RW), the standard MIB objects of: dot3OamMode (parallel to dot3OamDescrMode) and dot3OamLoopbackIgnoreRx (parallel to dot3OamDescrLbRxOperation) will be supported by Agent RO.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 1..4294967295  

dot3OamXPeerState 1.3.6.1.4.1.164.3.1.6.1.6.2.1.2
This object reports the state of the Peer of the OAM EFM Link. unknown - at the initialization of the device, or after Reset, when there is still no data about the peer's state. operational - usually after unknown state, when device senses that peer is OK. linkFault - Loss of Signal is detected by the receiver. dyingGasp - Unrecoverable condition has occurred (e.g power failure) criticalEvent - Unspecified Critical Event has occured.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), operational(2), linkFault(3), dyingGasp(4), criticalEvent(5)  

ethIfMacLayer 1.3.6.1.4.1.164.3.1.6.1.7
OBJECT IDENTIFIER    

ethIfMacLayerEvents 1.3.6.1.4.1.164.3.1.6.1.7.0
OBJECT IDENTIFIER    

ethIfSrcMacCtrlTable 1.3.6.1.4.1.164.3.1.6.1.7.1
This table supports source MAC addresses control parameters per interface. Source MAC control will be used mainly for security. Only packets with certain source MAC Addresses will be allowed to access the device. The source MAC addresses can be static or learned. The static addresses will be defined by the user in another table: ethIfSrcMacCtrlAddrTable. The learned addresses will exist in the ethIfSrcMacCtrlAddrTable as well.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    EthIfSrcMacCtrlEntry

ethIfSrcMacCtrlEntry 1.3.6.1.4.1.164.3.1.6.1.7.1.1
An entry in the table.
Status: current Access: not-accessible
OBJECT-TYPE    
  EthIfSrcMacCtrlEntry  

ethIfSrcMacCtrlIndex 1.3.6.1.4.1.164.3.1.6.1.7.1.1.1
The index of the MAC Layer interface supporting source MAC control feature. It may be the ifIndex of the ETH/Bridge Port.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

ethIfSrcMacCtrlIdx2 1.3.6.1.4.1.164.3.1.6.1.7.1.1.2
A second index that can be used. For example: The VLAN ID for which the source MAC control feature is supported. When this index is not in use, its value will be: 9999.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

ethIfSrcMacCtrl 1.3.6.1.4.1.164.3.1.6.1.7.1.1.3
Enable or disable the source MAC control on the current interface. The device should not enable source MAC control if for the current interface there are more than ethIfSrcMacCtrlMaxPermitAddr addresses in the ethIfSrcMacCtrlAddrTable. Default value will be: disable (2).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(2), enable(3)  

ethIfSrcMacCtrlMaxPermitAddr 1.3.6.1.4.1.164.3.1.6.1.7.1.1.4
This is the maximum number of permitted MAC addresses (static and learned) for the current interface.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

ethIfSrcMacCtrlCurNumPermitAddr 1.3.6.1.4.1.164.3.1.6.1.7.1.1.5
This is the number of source MAC addresses currently permitted for the current interface.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

ethIfSrcMacCtrlFlushAddrCmd 1.3.6.1.4.1.164.3.1.6.1.7.1.1.6
When set to on (3) this command will erase all the learned addresses and invalid addresses of the selected interface in the ethIfSrcMacCtrlAddrTable. After operation is finished, Agent will turn the value to 'off'.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

ethIfSrcMacCtrlAging 1.3.6.1.4.1.164.3.1.6.1.7.1.1.7
The timeout period in seconds for aging out dynamically learned source MAC addresses. Valid Values: 0 - disable 10-1000000
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

ethIfSrcMacCtrlLocking 1.3.6.1.4.1.164.3.1.6.1.7.1.1.8
When set to lock (3) this command will lock the Source MAC Address learning. No more learned addresses will be added to the ethIfSrcMacCtrlAddrTable. When set to unlock (2) this command will unlock the Source MAC Address learning. Learned addresses will be added to the ethIfSrcMacCtrlAddrTable but the number of addresses in the table will not exceed ethIfSrcMacCtrlMaxPermitAddr. Default value is: unlock (2).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unlock(2), lock(3)  

ethIfSrcMacCtrlViolationAction 1.3.6.1.4.1.164.3.1.6.1.7.1.1.9
Determines the action that the device will take upon security violation. drop(2) - the violating packets will be dropped. dropNotify (3)- the violating packets will be dropped and notifications will be generated. Notifications may be for example: SNMP Traps, Syslog messages and log file new entries. shutdown (4) - the interface will be forced to shut down.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER drop(2), dropNotify(3), shutdown(4)  

ethIfSrcMacCtrlLastViolatingAddr 1.3.6.1.4.1.164.3.1.6.1.7.1.1.10
This object indicates the last MAC address that violated the security on the current interface. If no violation, the agent will return: 00-00-00-00-00-00 .
Status: current Access: read-write
OBJECT-TYPE    
  MacAddress  

ethIfSrcMacCtrlPortStatus 1.3.6.1.4.1.164.3.1.6.1.7.1.1.11
This object represents the operational status of the MAC Control feature on an interface. shutdown(2) - This indicates that the port is shutdown due to security violation. secureActive (3) - This indicates that the MAC Control interface security is operational and this interface is not shutdown due to security violation. secureInactive (4)- This indicates that the MAC Control is not operational.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER shutdown(2), secureActive(3), secureInactive(4)  

ethIfSrcMacCtrlAddrTable 1.3.6.1.4.1.164.3.1.6.1.7.2
This table shows which MAC Addresses are permitted when the source MAC control is enabled and which non permitted MAC Addresses attempted to access the current interface. It contains static source MAC Addresses as well as learned MAC Addresses. The user can configure Static permitted source MAC Addresses via this table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    EthIfSrcMacCtrlAddrEntry

ethIfSrcMacCtrlAddrEntry 1.3.6.1.4.1.164.3.1.6.1.7.2.1
An entry in the table.
Status: current Access: not-accessible
OBJECT-TYPE    
  EthIfSrcMacCtrlAddrEntry  

ethIfSrcMacCtrlAddrIndex 1.3.6.1.4.1.164.3.1.6.1.7.2.1.1
The index of the interface for which the source MAC addresses exist in this table. It may be the ifIndex of the ETH/Bridge Port.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

ethIfSrcMacCtrlAddr 1.3.6.1.4.1.164.3.1.6.1.7.2.1.2
A unicast source MAC address that was learned or statically configured for the current interface. Packets with this source MAC address will be accepted by the device.
Status: current Access: not-accessible
OBJECT-TYPE    
  MacAddress  

ethIfSrcMacCtrlAddrIdx3 1.3.6.1.4.1.164.3.1.6.1.7.2.1.3
A third index that can be used. For example: The VLAN ID for which the source MAC control feature is supported. When this index is not in use, its value will be: 9999.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

ethIfSrcMacCtrlAddrRowStatus 1.3.6.1.4.1.164.3.1.6.1.7.2.1.4
This MIB object will be used in order to create/delete a static row or delete an address that is not allowed to access the current interface (ethIfSrcMacCtrlAddrStatus= invalid(2)). Device will add the learned addresses to this table. It will not be possible to add a new static entry to this table while the number of existing rows is equal or more than ethIfSrcMacCtrlMaxPermitAddr. When ethIfSrcMacCtrl = enabled (3), the device will add learned entries only up to ethIfSrcMacCtrlMaxPermitAddr.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER active(1), createAndGo(4), destroy(6)  

ethIfSrcMacCtrlAddrStatus 1.3.6.1.4.1.164.3.1.6.1.7.2.1.5
The status of this entry. The meanings of the values are: invalid (2) - the current address is not allowed to access this interface. learned(3) - the current address was learned. mgmt (5) - the current address is static. It may exist in the MAC Table.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER invalid(2), learned(3), mgmt(5)  

ethIfMacAccessViolation 1.3.6.1.4.1.164.3.1.6.1.7.0.1
This trap indicates that an Access Violation occurred.
Status: current Access: read-only
NOTIFICATION-TYPE