RAD-ARC-MIB

File: RAD-ARC-MIB.mib (238433 bytes)

Imported modules

RFC1155-SMI IF-MIB RFC-1212
RFC-1215 RAD-MIB SNMPv2-TC
ATM-MIB SNMPv2-SMI SNMP-FRAMEWORK-MIB

Imported symbols

IpAddress ifIndex InterfaceIndex
ifAlias OBJECT-TYPE TRAP-TYPE
radAtm agnLed agnIndication
atmConfIfInputRate atmConfIfOutputRate DisplayString
RowStatus DateAndTime atmVplVpi
atmVclVpi atmVclVci atmNte
atmNtePrt atmNteEvents atmNtePrtConfig
NOTIFICATION-TYPE Counter32 Gauge32
Integer32 SnmpAdminString atmInterfaceAlarmStatus
alarmSeverity alarmState radSysAtmEvents

Defined Types

AtmIfDataEntry  
SEQUENCE    
  atmIfTimeElapsed Integer32
  atmIfValidIntervals Integer32

AtmIfCurrentEntry  
SEQUENCE    
  atmIfCurrentTxCells Gauge32
  atmIfCurrentRxCells Gauge32
  atmIfCurrentCorrectedHecs Gauge32
  atmIfCurrentUncorrectedHecs Gauge32
  atmIfCurrentHecErrorSeconds Gauge32

AtmIfIntervalEntry  
SEQUENCE    
  atmIfIntervalNumber Integer32
  atmIfIntervalTxCells Gauge32
  atmIfIntervalRxCells Gauge32
  atmIfIntervalCorrectedHecs Gauge32
  atmIfIntervalUncorrectedHecs Gauge32
  atmIfIntervalHecErrorSeconds Gauge32

AtmVpCurrentEntry  
SEQUENCE    
  atmVpCurrentVpi Integer32
  atmVpCurrentRxCellsClp01 Gauge32
  atmVpCurrentRxCellsClp0 Gauge32
  atmVpCurrentGcra0Violations Gauge32
  atmVpCurrentGcra1Violations Gauge32
  atmVpCurrentRxAIS Gauge32
  atmVpCurrentTxAIS Gauge32
  atmVpCurrentRxRDI Gauge32
  atmVpCurrentTxRDI Gauge32
  atmVpCurrentContinuityLoss Gauge32
  atmVpCurrentUAS Gauge32
  atmVpCurrentSES Gauge32
  atmVpCurrentCDC Gauge32
  atmVpCurrentTotalDiscards Gauge32
  atmVpCurrentClp0Discards Gauge32
  atmVpCurrentTotalCellOuts Gauge32
  atmVpCurrentClp0CellOuts Gauge32
  atmVpCurrentTaggedOuts Gauge32
  atmVpCurrentPCR Gauge32
  atmVpCurrentSCR Gauge32
  atmVpCurrentMCR Gauge32
  atmVpCurrentShaperTotalDiscards Gauge32
  atmVpCurrentShaperClp0Discards Gauge32
  atmVpCurrentShaperClp1Discards Gauge32

AtmVpPMCurrentEntry  
SEQUENCE    
  atmVpPMCurrentDir INTEGER
  atmVpPMCurrentVpi Integer32
  atmVpPMCurrentTxClp01 Gauge32
  atmVpPMCurrentTxClp0 Gauge32
  atmVpPMCurrentRxClp01 Gauge32
  atmVpPMCurrentRxClp0 Gauge32
  atmVpPMCurrentErroredCells Gauge32
  atmVpPMCurrentLostCells Gauge32
  atmVpPMCurrentMisinsertedCells Gauge32
  atmVpPMCurrentECB Gauge32
  atmVpPMCurrentSECB Gauge32
  atmVpPMCurrentES Gauge32
  atmVpPMCurrentSES Gauge32
  atmVpPMCurrentUAS Gauge32
  atmVpPMCurrentIntervalQuality INTEGER
  atmVpPMCurrentLastDayQuality INTEGER

AtmVpIntervalEntry  
SEQUENCE    
  atmVpIntervalVpi Integer32
  atmVpIntervalNumber Integer32
  atmVpIntervalRxCellsClp01 Gauge32
  atmVpIntervalRxCellsClp0 Gauge32
  atmVpIntervalGcra0Violations Gauge32
  atmVpIntervalGcra1Violations Gauge32
  atmVpIntervalRxAIS Gauge32
  atmVpIntervalTxAIS Gauge32
  atmVpIntervalRxRDI Gauge32
  atmVpIntervalTxRDI Gauge32
  atmVpIntervalContinuityLoss Gauge32
  atmVpIntervalUAS Gauge32
  atmVpIntervalSES Gauge32
  atmVpIntervalCDC Gauge32
  atmVpIntervalTotalDiscards Gauge32
  atmVpIntervalClp0Discards Gauge32
  atmVpIntervalTotalCellOuts Gauge32
  atmVpIntervalClp0CellOuts Gauge32
  atmVpIntervalTaggedOuts Gauge32
  atmVpIntervalPCR Gauge32
  atmVpIntervalSCR Gauge32
  atmVpIntervalMCR Gauge32
  atmVpIntervalShaperTotalDiscards Gauge32
  atmVpIntervalShaperClp0Discards Gauge32
  atmVpIntervalShaperClp1Discards Gauge32

AtmVpPMIntervalEntry  
SEQUENCE    
  atmVpPMIntervalVpi Integer32
  atmVpPMIntervalDir INTEGER
  atmVpPMIntervalNumber Integer32
  atmVpPMIntervalTxClp01 Gauge32
  atmVpPMIntervalTxClp0 Gauge32
  atmVpPMIntervalRxClp01 Gauge32
  atmVpPMIntervalRxClp0 Gauge32
  atmVpPMIntervalErroredCells Gauge32
  atmVpPMIntervalLostCells Gauge32
  atmVpPMIntervalMisinsertedCells Gauge32
  atmVpPMIntervalECB Gauge32
  atmVpPMIntervalSECB Gauge32
  atmVpPMIntervalES Gauge32
  atmVpPMIntervalSES Gauge32
  atmVpPMIntervalUAS Gauge32
  atmVpPMIntervalQuality INTEGER
  atmVpPMIntervalLastDayQuality INTEGER

AtmVpQoSEntry  
SEQUENCE    
  atmVpQoSPeriodRef INTEGER
  atmVpQoSElapsedTime Integer32
  atmVpQoSUAS Gauge32

AtmVpPMQoSEntry  
SEQUENCE    
  atmVpPMQoSDirection INTEGER
  atmVpPMQoSPeriodRef INTEGER
  atmVpPMQoSCLR Gauge32
  atmVpPMQoSCER Gauge32
  atmVpPMQoSCMR Gauge32

AtmVpShaperStatEntry  
SEQUENCE    
  atmVpShaperDiscarded Counter32
  atmVpShaperOccupation Integer32
  atmVpShaperMaxOccupation Integer32
  atmVpShaperLevel INTEGER
  atmVpShaperEpdDropped Counter32
  atmVpShaperTotalEpdDropped Counter32

AtmVcCurrentEntry  
SEQUENCE    
  atmVcCurrentVpi Integer32
  atmVcCurrentVci Integer32
  atmVcCurrentRxCellsClp01 Gauge32
  atmVcCurrentRxCellsClp0 Gauge32
  atmVcCurrentGcra0Violations Gauge32
  atmVcCurrentGcra1Violations Gauge32
  atmVcCurrentRxAIS Gauge32
  atmVcCurrentTxAIS Gauge32
  atmVcCurrentRxRDI Gauge32
  atmVcCurrentTxRDI Gauge32
  atmVcCurrentContinuityLoss Gauge32
  atmVcCurrentUAS Gauge32
  atmVcCurrentSES Gauge32
  atmVcCurrentCDC Gauge32
  atmVcCurrentTotalDiscards Gauge32
  atmVcCurrentClp0Discards Gauge32
  atmVcCurrentTotalCellOuts Gauge32
  atmVcCurrentClp0CellOuts Gauge32
  atmVcCurrentTaggedOuts Gauge32
  atmVcCurrentPCR Gauge32
  atmVcCurrentSCR Gauge32
  atmVcCurrentMCR Gauge32
  atmVcCurrentShaperTotalDiscards Gauge32
  atmVcCurrentShaperClp0Discards Gauge32
  atmVcCurrentShaperClp1Discards Gauge32

AtmVcPMCurrentEntry  
SEQUENCE    
  atmVcPMCurrentVpi Integer32
  atmVcPMCurrentVci Integer32
  atmVcPMCurrentDir Integer32
  atmVcPMCurrentTxClp01 Gauge32
  atmVcPMCurrentTxClp0 Gauge32
  atmVcPMCurrentRxClp01 Gauge32
  atmVcPMCurrentRxClp0 Gauge32
  atmVcPMCurrentErroredCells Gauge32
  atmVcPMCurrentLostCells Gauge32
  atmVcPMCurrentMisinsertedCells Gauge32
  atmVcPMCurrentECB Gauge32
  atmVcPMCurrentSECB Gauge32
  atmVcPMCurrentES Gauge32
  atmVcPMCurrentSES Gauge32
  atmVcPMCurrentUAS Gauge32
  atmVcPMCurrentIntervalQuality INTEGER
  atmVcPMCurrentLastDayQuality INTEGER

AtmVcIntervalEntry  
SEQUENCE    
  atmVcIntervalVpi Integer32
  atmVcIntervalVci Integer32
  atmVcIntervalNumber Integer32
  atmVcIntervalRxCellsClp01 Gauge32
  atmVcIntervalRxCellsClp0 Gauge32
  atmVcIntervalGcra0Violations Gauge32
  atmVcIntervalGcra1Violations Gauge32
  atmVcIntervalRxAIS Gauge32
  atmVcIntervalTxAIS Gauge32
  atmVcIntervalRxRDI Gauge32
  atmVcIntervalTxRDI Gauge32
  atmVcIntervalContinuityLoss Gauge32
  atmVcIntervalUAS Gauge32
  atmVcIntervalSES Gauge32
  atmVcIntervalCDC Gauge32
  atmVcIntervalTotalDiscards Gauge32
  atmVcIntervalClp0Discards Gauge32
  atmVcIntervalTotalCellOuts Gauge32
  atmVcIntervalClp0CellOuts Gauge32
  atmVcIntervalTaggedOuts Gauge32
  atmVcIntervalPCR Gauge32
  atmVcIntervalSCR Gauge32
  atmVcIntervalMCR Gauge32
  atmVcIntervalShaperTotalDiscards Gauge32
  atmVcIntervalShaperClp0Discards Gauge32
  atmVcIntervalShaperClp1Discards Gauge32

AtmVcPMIntervalEntry  
SEQUENCE    
  atmVcPMIntervalVpi Integer32
  atmVcPMIntervalVci Integer32
  atmVcPMIntervalDir INTEGER
  atmVcPMIntervalNumber Integer32
  atmVcPMIntervalTxClp01 Gauge32
  atmVcPMIntervalTxClp0 Gauge32
  atmVcPMIntervalRxClp01 Gauge32
  atmVcPMIntervalRxClp0 Gauge32
  atmVcPMIntervalErroredCells Gauge32
  atmVcPMIntervalLostCells Gauge32
  atmVcPMIntervalMisinsertedCells Gauge32
  atmVcPMIntervalECB Gauge32
  atmVcPMIntervalSECB Gauge32
  atmVcPMIntervalES Gauge32
  atmVcPMIntervalSES Gauge32
  atmVcPMIntervalUAS Gauge32
  atmVcPMIntervalQuality INTEGER
  atmVcPMIntervalLastDayQuality INTEGER

AtmVcQoSEntry  
SEQUENCE    
  atmVcQoSPeriodRef INTEGER
  atmVcQoSElapsedTime Integer32
  atmVcQoSUAS Gauge32

AtmVcPMQoSEntry  
SEQUENCE    
  atmVcPMQoSDirection INTEGER
  atmVcPMQoSPeriodRef INTEGER
  atmVcPMQoSCLR Gauge32
  atmVcPMQoSCER Gauge32
  atmVcPMQoSCMR Gauge32

AtmVcShaperStatEntry  
SEQUENCE    
  atmVcShaperDiscarded Counter32
  atmVcShaperOccupation Integer32
  atmVcShaperMaxOccupation Integer32
  atmVcShaperLevel INTEGER
  atmVcShaperEpdDropped Counter32
  atmVcShaperTotalEpdDropped Counter32

AtmIntervalDateEntry  
SEQUENCE    
  atmIntervalDateInterval Integer32
  atmIntervalDateDate DisplayString
  atmIntervalDateTime DisplayString

AtmNteManagerEntry  
SEQUENCE    
  atmNteManagerIP IpAddress
  atmNteManagerPvc Integer32
  atmNteManagerIfIndex Integer32
  atmNteManagerVpi Integer32
  atmNteManagerVci Integer32
  atmNteManagerTrapMask Integer32
  atmNteManagerRowStatus RowStatus
  atmNteManagerNextHop IpAddress
  atmNteManagerVlanSupport INTEGER
  atmNteManagerVlanIdentifier Integer32
  atmNteManagerVlanFramePriority Integer32
  atmNteManagerAlarmTrapMask OCTET STRING
  atmNteManagerConfigPorts Integer32

AtmNteConfOamIfEntry  
SEQUENCE    
  atmNteConfOamIfAisRdi INTEGER

AtmNteHostIfEntry  
SEQUENCE    
  atmNteHostPvcIndex Integer32
  atmNteHostIP IpAddress
  atmNteHostMask IpAddress
  atmNteHostAtmIfIndex Integer32
  atmNteHostVpi Integer32
  atmNteHostVci Integer32
  atmNteHostRowStatus RowStatus
  atmNteHostRdnVpi Integer32
  atmNteHostRdnVci Integer32
  atmNteHostDefaultNextHop IpAddress
  atmNteHostVlanTagging INTEGER
  atmNteHostDefaultVlanID Integer32
  atmNteHostDefaultVlanPriority Integer32

AtmNteOamEntry  
SEQUENCE    
  atmNteOamMode INTEGER
  atmNteOamCellType INTEGER
  atmNteOamLevel INTEGER
  atmNteOamEnable INTEGER

AtmAlarmForwardingEntry  
SEQUENCE    
  atmAlarmForwardingFailPort Integer32
  atmAlarmForwardingToPort Integer32
  atmAlarmForwardingRowStatus RowStatus
  atmAlarmForwardingFailureLevel BITS
  atmAlarmForwardingRecoveryMode INTEGER
  atmAlarmForwardingRecoveryCommand INTEGER

AtmVpCrossConnectExtenEntry  
SEQUENCE    
  atmVpCrossConnectName SnmpAdminString

AtmVcCrossConnectExtenEntry  
SEQUENCE    
  atmVcCrossConnectName SnmpAdminString

AtmNteIdEntry  
SEQUENCE    
  atmNteIdIndex Integer32
  atmNteUnitId Integer32
  atmNteUnitVersion DisplayString
  atmNteCardType INTEGER
  atmNteCardStatus INTEGER
  atmNteCardCmd INTEGER

AtmSysIntervalEntry  
SEQUENCE    
  atmSysIntervalNumber Integer32
  atmSysIntervalCdc Gauge32

AtmLoopbackVpEntry  
SEQUENCE    
  atmLoopbackVpIfIndex Integer32
  atmLoopbackVpVpi Integer32
  atmLoopbackVpOperStatus INTEGER
  atmLoopbackVpCDV Integer32
  atmLoopbackVpAverageDelay Integer32
  atmLoopbackVpMaxDelay Integer32
  atmLoopbackVpMinDelay Integer32
  atmLoopbackVpErrSessions Integer32

AtmLoopbackVcEntry  
SEQUENCE    
  atmLoopbackVcIfIndex Integer32
  atmLoopbackVcVpi Integer32
  atmLoopbackVcVci Integer32
  atmLoopbackVcOperStatus INTEGER
  atmLoopbackVcCDV Integer32
  atmLoopbackVcAverageDelay Integer32
  atmLoopbackVcMaxDelay Integer32
  atmLoopbackVcMinDelay Integer32
  atmLoopbackVcErrSessions Integer32

AtmLoopbackVpIvlEntry  
SEQUENCE    
  atmLoopbackVpIvlIfIndex Integer32
  atmLoopbackVpIvlVpi Integer32
  atmLoopbackVpIvlIvl Integer32
  atmLoopbackVpIvlOperStatus INTEGER
  atmLoopbackVpIvlCDV Integer32
  atmLoopbackVpIvlAverageDelay Integer32
  atmLoopbackVpIvlMaxDelay Integer32
  atmLoopbackVpIvlMinDelay Integer32
  atmLoopbackVpIvlErrSessions Integer32

AtmLoopbackVcIvlEntry  
SEQUENCE    
  atmLoopbackVcIvlIfIndex Integer32
  atmLoopbackVcIvlVpi Integer32
  atmLoopbackVcIvlVci Integer32
  atmLoopbackVcIvlIvl Integer32
  atmLoopbackVcIvlOperStatus INTEGER
  atmLoopbackVcIvlCDV Integer32
  atmLoopbackVcIvlAverageDelay Integer32
  atmLoopbackVcIvlMaxDelay Integer32
  atmLoopbackVcIvlMinDelay Integer32
  atmLoopbackVcIvlErrSessions Integer32

AtmVpPmEntry  
SEQUENCE    
  atmVpPmIfIndex Integer32
  atmVpPmVpi Integer32
  atmVpPmAdminStatus INTEGER
  atmVpPmDirection INTEGER
  atmVpPmBlockSize Integer32
  atmVpPmRowStatus RowStatus
  atmVpPmSink INTEGER
  atmVpPmSource INTEGER

AtmVcPmEntry  
SEQUENCE    
  atmVcPmIfIndex Integer32
  atmVcPmVpi Integer32
  atmVcPmVci Integer32
  atmVcPmAdminStatus INTEGER
  atmVcPmDirection INTEGER
  atmVcPmBlockSize Integer32
  atmVcPmRowStatus RowStatus
  atmVcPmSink INTEGER
  atmVcPmSource INTEGER

AtmNteMdlConfigEntry  
SEQUENCE    
  atmNteMdlSlotIndex Integer32
  atmNteMdlPrtCpuSharing INTEGER
  atmNteMdlInputPriorityMechanism INTEGER

AtmGenSysSelfTestEntry  
SEQUENCE    
  atmGenSysSelfTestIndex Integer32
  atmGenSysSelfTestResult DisplayString

AtmGenSysLogEntry  
SEQUENCE    
  atmGenSysLogIndex Integer32
  atmGenSysLogMessage DisplayString

AtmGenSysCxRefEntry  
SEQUENCE    
  atmGenSysCxRefIndex Integer32
  atmGenSysCxRefCounter Gauge32

AtmCESAAL1StatsEntry  
SEQUENCE    
  atmCESAAL1SeqErrors Counter32
  atmCESAAL1HdrErrors Counter32
  atmCESAAL1PointerReframes Counter32
  atmCESAAL1BufUnderflows Counter32
  atmCESAAL1BufOverflows Counter32

AtmNteConfVcEntry  
SEQUENCE    
  atmConfVcPolicing INTEGER
  atmConfVcCCAdminStatus INTEGER
  atmConfVcLoopbackAdminStatus INTEGER
  atmConfVcLoopbackSinkAddress OCTET STRING
  atmConfVcCongestionControl OCTET STRING
  atmConfVcCCDirection INTEGER
  atmConfVcCreationTime DateAndTime
  atmConfVcOamSupport INTEGER
  atmConfVcCCActivationCtrl INTEGER
  atmConfVcCCOperStatus INTEGER
  atmConfVcLoopbackTraffic INTEGER
  atmConfVcLoopbackFailureInd INTEGER
  atmConfVcLoopbackFailureThreshold Integer32
  atmConfVcOamDirection INTEGER
  atmConfVcName DisplayString
  atmConfVcConnected INTEGER
  atmConfVcOamDescrIndex Integer32

Defined Values

atmGen 1.3.6.1.4.1.164.12.2
OBJECT IDENTIFIER    

atmPerfHistory 1.3.6.1.4.1.164.12.2.1
OBJECT IDENTIFIER    

atmIfPerformance 1.3.6.1.4.1.164.12.2.1.1
OBJECT IDENTIFIER    

aal5VccXTable 1.3.6.1.4.1.164.12.2.1.1.4
OBJECT IDENTIFIER    

atmIfDataTable 1.3.6.1.4.1.164.12.2.1.1.1
The ATM interface Data table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmIfDataEntry

atmIfDataEntry 1.3.6.1.4.1.164.12.2.1.1.1.1
An entry in the ATM interface Data table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmIfDataEntry  

atmIfTimeElapsed 1.3.6.1.4.1.164.12.2.1.1.1.1.1
The number of seconds that have elapsed since the beginning of the near end current error- measurement period.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..899  

atmIfValidIntervals 1.3.6.1.4.1.164.12.2.1.1.1.1.2
The number of previous near end intervals for which valid data was collected. The value will be 96 unless the interface was brought online within the last 24 hours, in which case the value will be the number of complete 15 minute near end intervals since the interface has been online.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..96  

atmIfCurrentTable 1.3.6.1.4.1.164.12.2.1.1.2
The ATM interface Current table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmIfCurrentEntry

atmIfCurrentEntry 1.3.6.1.4.1.164.12.2.1.1.2.1
An entry in the ATM interface Current table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmIfCurrentEntry  

atmIfCurrentTxCells 1.3.6.1.4.1.164.12.2.1.1.2.1.1
The counter associated with the number of transmitted cells, encountered by an ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmIfCurrentRxCells 1.3.6.1.4.1.164.12.2.1.1.2.1.2
The counter associated with the number of received cells, encountered by an ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmIfCurrentCorrectedHecs 1.3.6.1.4.1.164.12.2.1.1.2.1.3
The counter associated with the number of cells with corrected HEC errors, encountered by an ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmIfCurrentUncorrectedHecs 1.3.6.1.4.1.164.12.2.1.1.2.1.4
The counter associated with the number of cells with uncorrected HEC errors, encountered by an ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmIfCurrentHecErrorSeconds 1.3.6.1.4.1.164.12.2.1.1.2.1.5
The counter associated with the number of seconds with HEC errors, encountered by an ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmIfIntervalTable 1.3.6.1.4.1.164.12.2.1.1.3
The ATM interface Interval table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmIfIntervalEntry

atmIfIntervalEntry 1.3.6.1.4.1.164.12.2.1.1.3.1
An entry in the ATM interface Interval table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmIfIntervalEntry  

atmIfIntervalNumber 1.3.6.1.4.1.164.12.2.1.1.3.1.1
A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..96  

atmIfIntervalTxCells 1.3.6.1.4.1.164.12.2.1.1.3.1.2
The counter associated with the number of transmitted cells , encountered by an ATM interface in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmIfIntervalRxCells 1.3.6.1.4.1.164.12.2.1.1.3.1.3
The counter associated with the number of received cells, encountered by an ATM interface in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmIfIntervalCorrectedHecs 1.3.6.1.4.1.164.12.2.1.1.3.1.4
The counter associated with the number of cells with corrected HEC errors, encountered by an ATM interface in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmIfIntervalUncorrectedHecs 1.3.6.1.4.1.164.12.2.1.1.3.1.5
The counter associated with the number of cells with uncorrected HEC errors, encountered by an ATM interface in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmIfIntervalHecErrorSeconds 1.3.6.1.4.1.164.12.2.1.1.3.1.6
The counter associated with the number of seconds with HEC errors, encountered by an ATM interface in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmPvcPerformance 1.3.6.1.4.1.164.12.2.1.2
OBJECT IDENTIFIER    

atmVpPerformance 1.3.6.1.4.1.164.12.2.1.2.1
OBJECT IDENTIFIER    

atmVpCurrentTable 1.3.6.1.4.1.164.12.2.1.2.1.1
The ATM VP Current table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmVpCurrentEntry

atmVpCurrentEntry 1.3.6.1.4.1.164.12.2.1.2.1.1.1
An entry in the ATM VP Current table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmVpCurrentEntry  

atmVpCurrentVpi 1.3.6.1.4.1.164.12.2.1.2.1.1.1.1
The VPI of the VPL.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmVpCurrentRxCellsClp01 1.3.6.1.4.1.164.12.2.1.2.1.1.1.2
The counter associated with the number of transmitted cells, encountered by the VPL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpCurrentRxCellsClp0 1.3.6.1.4.1.164.12.2.1.2.1.1.1.3
The counter associated with the number of received cells, encountered by the VPL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpCurrentGcra0Violations 1.3.6.1.4.1.164.12.2.1.2.1.1.1.4
The counter associated with the number of cells violating GCRA0, encountered by the VPL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpCurrentGcra1Violations 1.3.6.1.4.1.164.12.2.1.2.1.1.1.5
The counter associated with the number of cells violating GCRA1, encountered by the VPL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpCurrentRxAIS 1.3.6.1.4.1.164.12.2.1.2.1.1.1.6
The counter associated with the number of received AIS cells, encountered by the VPL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpCurrentTxAIS 1.3.6.1.4.1.164.12.2.1.2.1.1.1.7
The counter associated with the number of transmitted AIS cells, encountered by the VPL of this ATM interface in the current 15 minute interval. Not Supported in the first phase.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpCurrentRxRDI 1.3.6.1.4.1.164.12.2.1.2.1.1.1.8
The counter associated with the number of received RDI cells, encountered by the VPL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpCurrentTxRDI 1.3.6.1.4.1.164.12.2.1.2.1.1.1.9
The counter associated with the number of transmitted RDI cells, encountered by the VPL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpCurrentContinuityLoss 1.3.6.1.4.1.164.12.2.1.2.1.1.1.10
The counter associated with the number of loss of continuity cells, encountered by the VPL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpCurrentUAS 1.3.6.1.4.1.164.12.2.1.2.1.1.1.11
The counter associated with the number of Unavailable Seconds, encountered by the VPL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpCurrentSES 1.3.6.1.4.1.164.12.2.1.2.1.1.1.12
The counter associated with the number of Severerly Errored Seconds, encountered by the VPL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpCurrentCDC 1.3.6.1.4.1.164.12.2.1.2.1.1.1.13
Amount of cells dropped in the current 15 minute interval of the VP connection.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpCurrentTotalDiscards 1.3.6.1.4.1.164.12.2.1.2.1.1.1.14
The total number of valid ATM cells discarded by the traffic policing entity. This includes cells originally received with CLP=0 and CLP=1.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpCurrentClp0Discards 1.3.6.1.4.1.164.12.2.1.2.1.1.1.15
The total number of valid ATM cells received with CLP=0 and discarded by the traffic policing entity.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpCurrentTotalCellOuts 1.3.6.1.4.1.164.12.2.1.2.1.1.1.16
The total number of valid ATM cells transmitted by this VPL. This includes both CLP=0 and CLP=1 cells.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpCurrentClp0CellOuts 1.3.6.1.4.1.164.12.2.1.2.1.1.1.17
The total number of valid ATM cells transmitted with CLP=0 by this VPL.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpCurrentTaggedOuts 1.3.6.1.4.1.164.12.2.1.2.1.1.1.18
The total number of valid ATM cells tagged by the traffic policing entity from CLP=0 to CLP=1 and transmitted by this VPL.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpCurrentPCR 1.3.6.1.4.1.164.12.2.1.2.1.1.1.19
The maximum traffic rate encountered in the last interval of the VP connection (monitored once a second).
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpCurrentSCR 1.3.6.1.4.1.164.12.2.1.2.1.1.1.20
The average traffic rate during the last interval of the VP connection.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpCurrentMCR 1.3.6.1.4.1.164.12.2.1.2.1.1.1.21
MCR - The minimum traffic rate encountered in the last interval of the VP connection (monitored once a second).
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpCurrentShaperTotalDiscards 1.3.6.1.4.1.164.12.2.1.2.1.1.1.22
The total number of cells (CLP0 and CLP1) discarded due to congestion by the traffic shaper.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpCurrentShaperClp0Discards 1.3.6.1.4.1.164.12.2.1.2.1.1.1.23
The total number of CLP0 cells discarded due to congestion by the traffic shaper.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpCurrentShaperClp1Discards 1.3.6.1.4.1.164.12.2.1.2.1.1.1.24
The total number of CLP1 cells discarded due to congestion by the traffic shaper.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpPMCurrentTable 1.3.6.1.4.1.164.12.2.1.2.1.2
The ATM VP Current table for Performance Management.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmVpPMCurrentEntry

atmVpPMCurrentEntry 1.3.6.1.4.1.164.12.2.1.2.1.2.1
An entry in the ATM VP Current table for Performance Management.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmVpPMCurrentEntry  

atmVpPMCurrentVpi 1.3.6.1.4.1.164.12.2.1.2.1.2.1.1
The VPI of the VPL.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmVpPMCurrentDir 1.3.6.1.4.1.164.12.2.1.2.1.2.1.2
The direction of performance management.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER forward(2), backward(3)  

atmVpPMCurrentTxClp01 1.3.6.1.4.1.164.12.2.1.2.1.2.1.3
The counter associated with the number of transmitted CLP 0+1 cells, encountered by the VPL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpPMCurrentTxClp0 1.3.6.1.4.1.164.12.2.1.2.1.2.1.4
The counter associated with the number of transmitted CLP 0 cells, encountered by the VPL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpPMCurrentRxClp01 1.3.6.1.4.1.164.12.2.1.2.1.2.1.5
The counter associated with the number of received CLP 0+1 cells, encountered by the VPL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpPMCurrentRxClp0 1.3.6.1.4.1.164.12.2.1.2.1.2.1.6
The counter associated with the number of received CLP 0 cells, encountered by the VPL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpPMCurrentErroredCells 1.3.6.1.4.1.164.12.2.1.2.1.2.1.7
The counter associated with the number of errored cells, encountered by the VPL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpPMCurrentLostCells 1.3.6.1.4.1.164.12.2.1.2.1.2.1.8
The counter associated with the number of lost cells, encountered by the VPL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpPMCurrentMisinsertedCells 1.3.6.1.4.1.164.12.2.1.2.1.2.1.9
The counter associated with the number of misinserted cells, encountered by the VPL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpPMCurrentECB 1.3.6.1.4.1.164.12.2.1.2.1.2.1.10
The counter associated with the number of ECB, encountered by the VPL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpPMCurrentSECB 1.3.6.1.4.1.164.12.2.1.2.1.2.1.11
The counter associated with the number of SECB, encountered by the VPL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpPMCurrentES 1.3.6.1.4.1.164.12.2.1.2.1.2.1.12
The counter associated with the number of Errored Seconds, encountered by the VPL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpPMCurrentSES 1.3.6.1.4.1.164.12.2.1.2.1.2.1.13
The counter associated with the number of Severely Errored Seconds, encountered by the VPL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpPMCurrentUAS 1.3.6.1.4.1.164.12.2.1.2.1.2.1.14
The counter associated with the number of Unavailable Seconds, encountered by the VPL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpPMCurrentIntervalQuality 1.3.6.1.4.1.164.12.2.1.2.1.2.1.15
If the number of errors per interval is superior to the atmNteUPLTCR value, the quality of service of the interval is declared as unacceptable.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(2), unacceptable(3)  

atmVpPMCurrentLastDayQuality 1.3.6.1.4.1.164.12.2.1.2.1.2.1.16
If the number of errors per 24 hours is superior to the atmNteDPLTCR value, the quality of service of the day is declared as degraded.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(2), degraded(4)  

atmVpIntervalTable 1.3.6.1.4.1.164.12.2.1.2.1.3
The ATM Vp Interval table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmVpIntervalEntry

atmVpIntervalEntry 1.3.6.1.4.1.164.12.2.1.2.1.3.1
An entry in the ATM Vp Interval table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmVpIntervalEntry  

atmVpIntervalVpi 1.3.6.1.4.1.164.12.2.1.2.1.3.1.1
The VPI of the VPL.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmVpIntervalNumber 1.3.6.1.4.1.164.12.2.1.2.1.3.1.2
A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..96  

atmVpIntervalRxCellsClp01 1.3.6.1.4.1.164.12.2.1.2.1.3.1.3
The counter associated with the number of transmitted cells , encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpIntervalRxCellsClp0 1.3.6.1.4.1.164.12.2.1.2.1.3.1.4
The counter associated with the number of received cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpIntervalGcra0Violations 1.3.6.1.4.1.164.12.2.1.2.1.3.1.5
The counter associated with the number of cells violating GCRA0, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpIntervalGcra1Violations 1.3.6.1.4.1.164.12.2.1.2.1.3.1.6
The counter associated with the number of cells violating GCRA1, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpIntervalRxAIS 1.3.6.1.4.1.164.12.2.1.2.1.3.1.7
The counter associated with the number of received AIS cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpIntervalTxAIS 1.3.6.1.4.1.164.12.2.1.2.1.3.1.8
The counter associated with the number of transmitted AIS cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals. Not supported in the first phase.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpIntervalRxRDI 1.3.6.1.4.1.164.12.2.1.2.1.3.1.9
The counter associated with the number of received RDI cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpIntervalTxRDI 1.3.6.1.4.1.164.12.2.1.2.1.3.1.10
The counter associated with the number of transmitted RDI cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpIntervalContinuityLoss 1.3.6.1.4.1.164.12.2.1.2.1.3.1.11
The counter associated with the number of Continuity Loss cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpIntervalUAS 1.3.6.1.4.1.164.12.2.1.2.1.3.1.12
The counter associated with the number of Unavailable Seconds, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpIntervalSES 1.3.6.1.4.1.164.12.2.1.2.1.3.1.13
The counter associated with the number of Severerly Errored Seconds, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpIntervalCDC 1.3.6.1.4.1.164.12.2.1.2.1.3.1.14
Amount of cells dropped in the 15 minute interval of the VP connection.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpIntervalTotalDiscards 1.3.6.1.4.1.164.12.2.1.2.1.3.1.15
The total number of valid ATM cells discarded by the traffic policing entity. This includes cells originally received with CLP=0 and CLP=1.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpIntervalClp0Discards 1.3.6.1.4.1.164.12.2.1.2.1.3.1.16
The total number of valid ATM cells received with CLP=0 an discarded by the traffic policing entity.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpIntervalTotalCellOuts 1.3.6.1.4.1.164.12.2.1.2.1.3.1.17
The total number of valid ATM cells transmitted by this VPL. This includes both CLP=0 and CLP=1 cells.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpIntervalClp0CellOuts 1.3.6.1.4.1.164.12.2.1.2.1.3.1.18
The total number of valid ATM cells transmitted with CLP=0 by this VPL.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpIntervalTaggedOuts 1.3.6.1.4.1.164.12.2.1.2.1.3.1.19
The total number of valid ATM cells tagged by the traffic policing entity from CLP=0 to CLP=1 and transmitted by this VPL.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpIntervalPCR 1.3.6.1.4.1.164.12.2.1.2.1.3.1.20
The maximum traffic rate encountered in the last interval of the VP connection (monitored once a second) encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpIntervalSCR 1.3.6.1.4.1.164.12.2.1.2.1.3.1.21
The average traffic rate during the last interval of the VP connection , encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpIntervalMCR 1.3.6.1.4.1.164.12.2.1.2.1.3.1.22
MCR - The minimum traffic rate encountered in the last interval of the VP connection (monitored once a second) encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpIntervalShaperTotalDiscards 1.3.6.1.4.1.164.12.2.1.2.1.3.1.23
The total number of cells (CLP0 and CLP1) discarded due to congestion by the traffic shaper.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpIntervalShaperClp0Discards 1.3.6.1.4.1.164.12.2.1.2.1.3.1.24
The total number of CLP0 cells discarded due to congestion by the traffic shaper.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpIntervalShaperClp1Discards 1.3.6.1.4.1.164.12.2.1.2.1.3.1.25
The total number of CLP1 cells discarded due to congestion by the traffic shaper.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpPMIntervalTable 1.3.6.1.4.1.164.12.2.1.2.1.4
The ATM Vp Interval table for Performance Management.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmVpPMIntervalEntry

atmVpPMIntervalEntry 1.3.6.1.4.1.164.12.2.1.2.1.4.1
An entry in the ATM Vp Interval table for Performance Management.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmVpPMIntervalEntry  

atmVpPMIntervalVpi 1.3.6.1.4.1.164.12.2.1.2.1.4.1.1
The VPI of the VPL.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmVpPMIntervalDir 1.3.6.1.4.1.164.12.2.1.2.1.4.1.2
The direction of performance management.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER forward(2), backward(3)  

atmVpPMIntervalNumber 1.3.6.1.4.1.164.12.2.1.2.1.4.1.3
A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..96  

atmVpPMIntervalTxClp01 1.3.6.1.4.1.164.12.2.1.2.1.4.1.4
The counter associated with the number of transmitted CLP 0+1 cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpPMIntervalTxClp0 1.3.6.1.4.1.164.12.2.1.2.1.4.1.5
The counter associated with the number of transmitted CLP 0 cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpPMIntervalRxClp01 1.3.6.1.4.1.164.12.2.1.2.1.4.1.6
The counter associated with the number of received CLP 0+1 cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpPMIntervalRxClp0 1.3.6.1.4.1.164.12.2.1.2.1.4.1.7
The counter associated with the number of received CLP 0 cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpPMIntervalErroredCells 1.3.6.1.4.1.164.12.2.1.2.1.4.1.8
The counter associated with the number of Errored cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpPMIntervalLostCells 1.3.6.1.4.1.164.12.2.1.2.1.4.1.9
The counter associated with the number of Lost cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpPMIntervalMisinsertedCells 1.3.6.1.4.1.164.12.2.1.2.1.4.1.10
The counter associated with the number of Misinserted cells, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpPMIntervalECB 1.3.6.1.4.1.164.12.2.1.2.1.4.1.11
The counter associated with the number of ECBs encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpPMIntervalSECB 1.3.6.1.4.1.164.12.2.1.2.1.4.1.12
The counter associated with the number of SECBs encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpPMIntervalES 1.3.6.1.4.1.164.12.2.1.2.1.4.1.13
The counter associated with the number of Errored Seconds, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpPMIntervalSES 1.3.6.1.4.1.164.12.2.1.2.1.4.1.14
The counter associated with the number of Severely Errored Seconds, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpPMIntervalUAS 1.3.6.1.4.1.164.12.2.1.2.1.4.1.15
The counter associated with the number of Unavailable Seconds, encountered by an ATM interface/VP in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpPMIntervalQuality 1.3.6.1.4.1.164.12.2.1.2.1.4.1.16
If the number of errors per interval is superior to the atmNteUPLTCR value, the quality of service of the interval is declared as unacceptable.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(2), unacceptable(3)  

atmVpPMIntervalLastDayQuality 1.3.6.1.4.1.164.12.2.1.2.1.4.1.17
If the number of errors per 24 hours is superior to the atmNteDPLTCR value, the quality of service of the day is declared as degraded.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(2), degraded(4)  

atmVpQoSTable 1.3.6.1.4.1.164.12.2.1.2.1.5
The VP QoS table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmVpQoSEntry

atmVpQoSEntry 1.3.6.1.4.1.164.12.2.1.2.1.5.1
.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmVpQoSEntry  

atmVpQoSPeriodRef 1.3.6.1.4.1.164.12.2.1.2.1.5.1.1
This object is an index that specifies which period of time, the next 2 objects refer to. currentPeriod - the period since last systemResetAllStatsCmd received or since Start-up (if no systemResetAllStatsCmd was received since Start-up) until now. lastPeriod - the period between last two commands of systemResetAllStatsCmd. - If only one command occurred since Start-up: the period between Start-up and last command. - If no command occurred since Start-up: this period will not actually exist. In this case, he following 5 objects will be 0.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER currentPeriod(1), lastPeriod(2)  

atmVpQoSElapsedTime 1.3.6.1.4.1.164.12.2.1.2.1.5.1.2
Elapsed Time in seconds. - for atmVpQoSPeriodRef = currentPeriod: The period since last systemResetAllStatsCmd received or since Start-up (if no systemResetAllStatsCmd was received since Start-up) until now. - for atmVpQoSPeriodRef = lastPeriod: The value of atmVpQoSElapsedTime when last systemResetAllStatsCmd was received.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmVpQoSUAS 1.3.6.1.4.1.164.12.2.1.2.1.5.1.3
Number of Unavailable Seconds for the reference period (atmVpQoSPeriodRef).
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpPMQoSTable 1.3.6.1.4.1.164.12.2.1.2.1.6
The PM VP QoS table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmVpPMQoSEntry

atmVpPMQoSEntry 1.3.6.1.4.1.164.12.2.1.2.1.6.1
.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmVpPMQoSEntry  

atmVpPMQoSDirection 1.3.6.1.4.1.164.12.2.1.2.1.6.1.1
The direction of performance management.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER forward(2), backward(3)  

atmVpPMQoSPeriodRef 1.3.6.1.4.1.164.12.2.1.2.1.6.1.2
This object is an index that specifies which period of time, the next 5 objects refer to. currentPeriod - the period since last systemResetAllStatsCmd received or since Start-up (if no systemResetAllStatsCmd was received since Start-up) until now. lastPeriod - the period between last two commands of systemResetAllStatsCmd. - If only one command occurred since Start-up: the period between Start-up and last command. - If no command occurred since Start-up: this period will not actually exist. In this case, he following 5 objects will be 0.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER currentPeriod(1), lastPeriod(2)  

atmVpPMQoSCLR 1.3.6.1.4.1.164.12.2.1.2.1.6.1.3
Cell Loss Ratio counter for the reference period (atmVpPMQoSPeriodRef)- defined in accordance with I.356 , in %. The value will be multipuled by 100.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpPMQoSCER 1.3.6.1.4.1.164.12.2.1.2.1.6.1.4
Cell Error Ratio counter for the reference period (atmVpPMQoSPeriodRef) defined in accordance with I.356 , in %. The value will be multipuled by 100.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpPMQoSCMR 1.3.6.1.4.1.164.12.2.1.2.1.6.1.5
Cell Misinsertion Ratio counter for the reference period (atmVpPMQoSPeriodRef) defined in accordance with I.356 , cells/sec .
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVpShaperStatTable 1.3.6.1.4.1.164.12.2.1.2.1.7
The ATM VP shaper statistics table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmVpShaperStatEntry

atmVpShaperStatEntry 1.3.6.1.4.1.164.12.2.1.2.1.7.1
An entry in the ATM VP shaper statistics table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmVpShaperStatEntry  

atmVpShaperDiscarded 1.3.6.1.4.1.164.12.2.1.2.1.7.1.1
The number of Cells that were discarded in the shaper on that VPC due to buffer overflow. This counter counts till it reaches its MAX value (20 bits) and then rolls over.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

atmVpShaperOccupation 1.3.6.1.4.1.164.12.2.1.2.1.7.1.2
The number of Cells that are currently stored in the buffer. This parameter is limited to 20 bits.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmVpShaperMaxOccupation 1.3.6.1.4.1.164.12.2.1.2.1.7.1.3
The Maximum number of Cells that were stored in the buffer, since this VP was activated. This parameter is limited to 20 bits.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmVpShaperLevel 1.3.6.1.4.1.164.12.2.1.2.1.7.1.4
The occupation of the buffer according to a predefined threshold. empty - buffer is Empty full - buffer is Full below - buffer is Below the threshold above - buffer is Above the threshold. This is also the trigger to start EPD\PPD mechanism, if set for the VPC.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER empty(1), full(2), below(3), above(4)  

atmVpShaperEpdDropped 1.3.6.1.4.1.164.12.2.1.2.1.7.1.5
The number of Cells that were dropped in the shaper on that VPC due to EPD\PPD mechanism in the last second. This parameter is limited to 24 bits. Applicable for a EPD/PPD VP only.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

atmVpShaperTotalEpdDropped 1.3.6.1.4.1.164.12.2.1.2.1.7.1.6
The Total number of Cells that were dropped in the shaper on that VPC due to EPD\PPD mechanism in the last 15 minutes. This counter automatically reset itself every 15 minutes. Applicable for a EPD/PPD VP only.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

atmVcPerformance 1.3.6.1.4.1.164.12.2.1.2.2
OBJECT IDENTIFIER    

atmVcCurrentTable 1.3.6.1.4.1.164.12.2.1.2.2.1
The ATM VC Current table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmVcCurrentEntry

atmVcCurrentEntry 1.3.6.1.4.1.164.12.2.1.2.2.1.1
An entry in the ATM VC Current table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmVcCurrentEntry  

atmVcCurrentVpi 1.3.6.1.4.1.164.12.2.1.2.2.1.1.1
The VPI of the VCL.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmVcCurrentVci 1.3.6.1.4.1.164.12.2.1.2.2.1.1.2
The VCI of the VCL.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmVcCurrentRxCellsClp01 1.3.6.1.4.1.164.12.2.1.2.2.1.1.3
The counter associated with the number of transmitted cells, encountered by the VCL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcCurrentRxCellsClp0 1.3.6.1.4.1.164.12.2.1.2.2.1.1.4
The counter associated with the number of received cells, encountered by the VCL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcCurrentGcra0Violations 1.3.6.1.4.1.164.12.2.1.2.2.1.1.5
The counter associated with the number of cells violating GCRA0, encountered by the VCL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcCurrentGcra1Violations 1.3.6.1.4.1.164.12.2.1.2.2.1.1.6
The counter associated with the number of cells violating GCRA1, encountered by the VCL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcCurrentRxAIS 1.3.6.1.4.1.164.12.2.1.2.2.1.1.7
The counter associated with the number of received AIS cells, encountered by the VCL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcCurrentTxAIS 1.3.6.1.4.1.164.12.2.1.2.2.1.1.8
The counter associated with the number of transmitted AIS cells, encountered by the VCL of this ATM interface in the current 15 minute interval. Not Supported in the first phase.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcCurrentRxRDI 1.3.6.1.4.1.164.12.2.1.2.2.1.1.9
The counter associated with the number of received RDI cells, encountered by the VCL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcCurrentTxRDI 1.3.6.1.4.1.164.12.2.1.2.2.1.1.10
The counter associated with the number of transmitted RDI cells, encountered by the VCL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcCurrentContinuityLoss 1.3.6.1.4.1.164.12.2.1.2.2.1.1.11
The counter associated with the number of loss of continuity cells, encountered by the VCL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcCurrentUAS 1.3.6.1.4.1.164.12.2.1.2.2.1.1.12
The counter associated with the number of Unavailable Seconds, encountered by the VCL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcCurrentSES 1.3.6.1.4.1.164.12.2.1.2.2.1.1.13
The counter associated with the number of Severerly Errored Seconds, encountered by the VCL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcCurrentCDC 1.3.6.1.4.1.164.12.2.1.2.2.1.1.14
Amount of cells dropped in the current 15 minute interval of the VC connection.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcCurrentTotalDiscards 1.3.6.1.4.1.164.12.2.1.2.2.1.1.15
The total number of valid ATM cells discarded by the traffic policing entity. This includes cells originally received with CLP=0 and CLP=1.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcCurrentClp0Discards 1.3.6.1.4.1.164.12.2.1.2.2.1.1.16
The total number of valid ATM cells received with CLP=0 an discarded by the traffic policing entity.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcCurrentTotalCellOuts 1.3.6.1.4.1.164.12.2.1.2.2.1.1.17
The total number of valid ATM cells transmitted by this VPL. This includes both CLP=0 and CLP=1 cells.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcCurrentClp0CellOuts 1.3.6.1.4.1.164.12.2.1.2.2.1.1.18
The total number of valid ATM cells transmitted with CLP=0 by this VPL.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcCurrentTaggedOuts 1.3.6.1.4.1.164.12.2.1.2.2.1.1.19
The total number of valid ATM cells tagged by the traffic policing entity from CLP=0 to CLP=1 and transmitted by this VPL.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcCurrentPCR 1.3.6.1.4.1.164.12.2.1.2.2.1.1.20
The maximum traffic rate encountered in the last interval of the VC connection (monitored once a second).
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcCurrentSCR 1.3.6.1.4.1.164.12.2.1.2.2.1.1.21
The average traffic rate during the last interval of the VC connection.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcCurrentMCR 1.3.6.1.4.1.164.12.2.1.2.2.1.1.22
MCR - The minimum traffic rate encountered in the last interval of the VC connection (monitored once a second).
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcCurrentShaperTotalDiscards 1.3.6.1.4.1.164.12.2.1.2.2.1.1.23
The total number of cells (CLP0 and CLP1) discarded due to congestion by the traffic shaper.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcCurrentShaperClp0Discards 1.3.6.1.4.1.164.12.2.1.2.2.1.1.24
The total number of CLP0 cells discarded due to congestion by the traffic shaper.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcCurrentShaperClp1Discards 1.3.6.1.4.1.164.12.2.1.2.2.1.1.25
The total number of CLP1 cells discarded due to congestion by the traffic shaper.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcPMCurrentTable 1.3.6.1.4.1.164.12.2.1.2.2.2
The ATM VC Current table for Performance Management.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmVcPMCurrentEntry

atmVcPMCurrentEntry 1.3.6.1.4.1.164.12.2.1.2.2.2.1
An entry in the ATM VC Current table for Performance Management.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmVcPMCurrentEntry  

atmVcPMCurrentVpi 1.3.6.1.4.1.164.12.2.1.2.2.2.1.1
The VPI of the VCL.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmVcPMCurrentVci 1.3.6.1.4.1.164.12.2.1.2.2.2.1.2
The VCI of the VCL.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmVcPMCurrentDir 1.3.6.1.4.1.164.12.2.1.2.2.2.1.3
The direction of Performance Management.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmVcPMCurrentTxClp01 1.3.6.1.4.1.164.12.2.1.2.2.2.1.4
The counter associated with the number of transmitted CLP 0+1 cells, encountered by the VCL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcPMCurrentTxClp0 1.3.6.1.4.1.164.12.2.1.2.2.2.1.5
The counter associated with the number of transmitted CLP 0 cells, encountered by the VCL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcPMCurrentRxClp01 1.3.6.1.4.1.164.12.2.1.2.2.2.1.6
The counter associated with the number of received CLP 0+1 cells, encountered by the VCL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcPMCurrentRxClp0 1.3.6.1.4.1.164.12.2.1.2.2.2.1.7
The counter associated with the number of received CLP 0 cells, encountered by the VCL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcPMCurrentErroredCells 1.3.6.1.4.1.164.12.2.1.2.2.2.1.8
The counter associated with the number of errored cells, encountered by the VCL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcPMCurrentLostCells 1.3.6.1.4.1.164.12.2.1.2.2.2.1.9
The counter associated with the number of lost cells, encountered by the VCL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcPMCurrentMisinsertedCells 1.3.6.1.4.1.164.12.2.1.2.2.2.1.10
The counter associated with the number of misinserted cells, encountered by the VCL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcPMCurrentECB 1.3.6.1.4.1.164.12.2.1.2.2.2.1.11
The counter associated with the number of ECBs encountered by the VCL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcPMCurrentSECB 1.3.6.1.4.1.164.12.2.1.2.2.2.1.12
The counter associated with the number of SECBs encountered by the VCL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcPMCurrentES 1.3.6.1.4.1.164.12.2.1.2.2.2.1.13
The counter associated with the number of Errored Seconds, encountered by the VCL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcPMCurrentSES 1.3.6.1.4.1.164.12.2.1.2.2.2.1.14
The counter associated with the number of Severely Errored Seconds, encountered by the VCL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcPMCurrentUAS 1.3.6.1.4.1.164.12.2.1.2.2.2.1.15
The counter associated with the number of Severely Errored Seconds, encountered by the VCL of this ATM interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcPMCurrentIntervalQuality 1.3.6.1.4.1.164.12.2.1.2.2.2.1.16
If the number of errors per interval is superior to the atmNteUPLTCR value, the quality of service of the interval is declared as unacceptable.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(2), unacceptable(3)  

atmVcPMCurrentLastDayQuality 1.3.6.1.4.1.164.12.2.1.2.2.2.1.17
If the number of errors per 24 hours is superior to the atmNteDPLTCR value, the quality of service of the day is declared as degraded.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(2), degraded(4)  

atmVcIntervalTable 1.3.6.1.4.1.164.12.2.1.2.2.3
The ATM Vc Interval table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmVcIntervalEntry

atmVcIntervalEntry 1.3.6.1.4.1.164.12.2.1.2.2.3.1
An entry in the ATM Vc Interval table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmVcIntervalEntry  

atmVcIntervalVpi 1.3.6.1.4.1.164.12.2.1.2.2.3.1.1
The VPI of the VCL.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmVcIntervalVci 1.3.6.1.4.1.164.12.2.1.2.2.3.1.2
The VCI of the VCL.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmVcIntervalNumber 1.3.6.1.4.1.164.12.2.1.2.2.3.1.3
A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..96  

atmVcIntervalRxCellsClp01 1.3.6.1.4.1.164.12.2.1.2.2.3.1.4
The counter associated with the number of transmitted cells , encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcIntervalRxCellsClp0 1.3.6.1.4.1.164.12.2.1.2.2.3.1.5
The counter associated with the number of received cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcIntervalGcra0Violations 1.3.6.1.4.1.164.12.2.1.2.2.3.1.6
The counter associated with the number of cells violating GCRA0, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcIntervalGcra1Violations 1.3.6.1.4.1.164.12.2.1.2.2.3.1.7
The counter associated with the number of cells violating GCRA1, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcIntervalRxAIS 1.3.6.1.4.1.164.12.2.1.2.2.3.1.8
The counter associated with the number of received AIS cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcIntervalTxAIS 1.3.6.1.4.1.164.12.2.1.2.2.3.1.9
The counter associated with the number of transmitted AIS cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals. Not supported in the first phase.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcIntervalRxRDI 1.3.6.1.4.1.164.12.2.1.2.2.3.1.10
The counter associated with the number of received RDI cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcIntervalTxRDI 1.3.6.1.4.1.164.12.2.1.2.2.3.1.11
The counter associated with the number of transmitted RDI cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcIntervalContinuityLoss 1.3.6.1.4.1.164.12.2.1.2.2.3.1.12
The counter associated with the number of Continuity Loss cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcIntervalUAS 1.3.6.1.4.1.164.12.2.1.2.2.3.1.13
The counter associated with the number of Unavailable Seconds, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcIntervalSES 1.3.6.1.4.1.164.12.2.1.2.2.3.1.14
The counter associated with the number of Severerly Errored Seconds, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcIntervalCDC 1.3.6.1.4.1.164.12.2.1.2.2.3.1.15
Amount of cells dropped in the 15 minute interval of the VC connection.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcIntervalTotalDiscards 1.3.6.1.4.1.164.12.2.1.2.2.3.1.16
The total number of valid ATM cells discarded by the traffic policing entity. This includes cells originally received with CLP=0 and CLP=1.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcIntervalClp0Discards 1.3.6.1.4.1.164.12.2.1.2.2.3.1.17
The total number of valid ATM cells received with CLP=0 an discarded by the traffic policing entity.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcIntervalTotalCellOuts 1.3.6.1.4.1.164.12.2.1.2.2.3.1.18
The total number of valid ATM cells transmitted by this VPL. This includes both CLP=0 and CLP=1 cells.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcIntervalClp0CellOuts 1.3.6.1.4.1.164.12.2.1.2.2.3.1.19
The total number of valid ATM cells transmitted with CLP=0 by this VPL.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcIntervalTaggedOuts 1.3.6.1.4.1.164.12.2.1.2.2.3.1.20
The total number of valid ATM cells tagged by the traffic policing entity from CLP=0 to CLP=1 and transmitted by this VPL.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcIntervalPCR 1.3.6.1.4.1.164.12.2.1.2.2.3.1.21
The maximum traffic rate encountered in the last interval of the VC connection (monitored once a second) encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcIntervalSCR 1.3.6.1.4.1.164.12.2.1.2.2.3.1.22
The average traffic rate during the last interval of the VC connection, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcIntervalMCR 1.3.6.1.4.1.164.12.2.1.2.2.3.1.23
MCR - The minimum traffic rate encountered in the last interval of the VC connection (monitored once a second) encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcIntervalShaperTotalDiscards 1.3.6.1.4.1.164.12.2.1.2.2.3.1.24
The total number of cells (CLP0 and CLP1) discarded due to congestion by the traffic shaper.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcIntervalShaperClp0Discards 1.3.6.1.4.1.164.12.2.1.2.2.3.1.25
The total number of CLP0 cells discarded due to congestion by the traffic shaper.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcIntervalShaperClp1Discards 1.3.6.1.4.1.164.12.2.1.2.2.3.1.26
The total number of CLP1 cells discarded due to congestion by the traffic shaper.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcPMIntervalTable 1.3.6.1.4.1.164.12.2.1.2.2.4
The ATM Vc Interval table for Performance Management.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmVcPMIntervalEntry

atmVcPMIntervalEntry 1.3.6.1.4.1.164.12.2.1.2.2.4.1
An entry in the ATM Vc Interval table for Performance Management.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmVcPMIntervalEntry  

atmVcPMIntervalVpi 1.3.6.1.4.1.164.12.2.1.2.2.4.1.1
The VPI of the VCL.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmVcPMIntervalVci 1.3.6.1.4.1.164.12.2.1.2.2.4.1.2
The VCI of the VCL.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmVcPMIntervalDir 1.3.6.1.4.1.164.12.2.1.2.2.4.1.3
The direction of Performance Management.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER forward(2), backward(3)  

atmVcPMIntervalNumber 1.3.6.1.4.1.164.12.2.1.2.2.4.1.4
A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..96  

atmVcPMIntervalTxClp01 1.3.6.1.4.1.164.12.2.1.2.2.4.1.5
The counter associated with the number of transmitted CLP 0+1 cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcPMIntervalTxClp0 1.3.6.1.4.1.164.12.2.1.2.2.4.1.6
The counter associated with the number of transmitted CLP 0 cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcPMIntervalRxClp01 1.3.6.1.4.1.164.12.2.1.2.2.4.1.7
The counter associated with the number of received CLP 0+1 cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcPMIntervalRxClp0 1.3.6.1.4.1.164.12.2.1.2.2.4.1.8
The counter associated with the number of received CLP 0 cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcPMIntervalErroredCells 1.3.6.1.4.1.164.12.2.1.2.2.4.1.9
The counter associated with the number of Errored cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcPMIntervalLostCells 1.3.6.1.4.1.164.12.2.1.2.2.4.1.10
The counter associated with the number of Lost cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcPMIntervalMisinsertedCells 1.3.6.1.4.1.164.12.2.1.2.2.4.1.11
The counter associated with the number of Misinserted cells, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcPMIntervalECB 1.3.6.1.4.1.164.12.2.1.2.2.4.1.12
The counter associated with the number of ECBs encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcPMIntervalSECB 1.3.6.1.4.1.164.12.2.1.2.2.4.1.13
The counter associated with the number of SECBs encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcPMIntervalES 1.3.6.1.4.1.164.12.2.1.2.2.4.1.14
The counter associated with the number of Errored Seconds, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcPMIntervalSES 1.3.6.1.4.1.164.12.2.1.2.2.4.1.15
The counter associated with the number of Severely Errored Seconds, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcPMIntervalUAS 1.3.6.1.4.1.164.12.2.1.2.2.4.1.16
The counter associated with the number of Unavailable Seconds, encountered by an ATM interface/VC in one of the previous 96, individual 15 minute, intervals.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcPMIntervalQuality 1.3.6.1.4.1.164.12.2.1.2.2.4.1.17
If the number of errors per interval is superior to the atmNteUPLTCR value, the quality of service of the interval is declared as unacceptable.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(2), unacceptable(3)  

atmVcPMIntervalLastDayQuality 1.3.6.1.4.1.164.12.2.1.2.2.4.1.18
If the number of errors per 24 hours is superior to the atmNteDPLTCR value, the quality of service of the day is declared as degraded.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(2), degraded(4)  

atmVcQoSTable 1.3.6.1.4.1.164.12.2.1.2.2.6
The ATM VP QoS table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmVcQoSEntry

atmVcQoSEntry 1.3.6.1.4.1.164.12.2.1.2.2.6.1
An entry in the ATM VP table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmVcQoSEntry  

atmVcQoSPeriodRef 1.3.6.1.4.1.164.12.2.1.2.2.6.1.1
This object is an index that specifies which period of time, the next 2 objects refer to. currentPeriod - the period since last systemResetAllStatsCmd received or since Start-up (if no systemResetAllStatsCmd was received since Start-up) until now. lastPeriod - the period between last two commands of systemResetAllStatsCmd. - If only one command occurred since Start-up: the period between Start-up and last command. - If no command occurred since Start-up: this period will not actually exist. In this case, he following 5 objects will be 0.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER currentPeriod(1), lastPeriod(2)  

atmVcQoSElapsedTime 1.3.6.1.4.1.164.12.2.1.2.2.6.1.2
Elapsed Time in seconds. - for atmVcQoSPeriodRef = currentPeriod: The period since last systemResetAllStatsCmd received or since Start-up (if no systemResetAllStatsCmd was received since Start-up) until now. - for atmVcQoSPeriodRef = lastPeriod: The value of atmVcQoSElapsedTime when last systemResetAllStatsCmd was received.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmVcQoSUAS 1.3.6.1.4.1.164.12.2.1.2.2.6.1.3
Number of Unavailable Seconds for the reference period (atmVcQoSPeriodRef).
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcPMQoSTable 1.3.6.1.4.1.164.12.2.1.2.2.7
The PM VC QoS table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmVcPMQoSEntry

atmVcPMQoSEntry 1.3.6.1.4.1.164.12.2.1.2.2.7.1
An entry in the VC PM QoS table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmVcPMQoSEntry  

atmVcPMQoSDirection 1.3.6.1.4.1.164.12.2.1.2.2.7.1.1
The direction of performance management.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER forward(2), backward(3)  

atmVcPMQoSPeriodRef 1.3.6.1.4.1.164.12.2.1.2.2.7.1.2
This object is an index that specifies which period of time, the next 5 objects refer to. currentPeriod - the period since last systemResetAllStatsCmd received or since Start-up (if no systemResetAllStatsCmd was received since Start-up) until now. lastPeriod - the period between last two commands of systemResetAllStatsCmd. - If only one command occurred since Start-up: the period between Start-up and last command. - If no command occurred since Start-up: this period will not actually exist. In this case, he following 5 objects will be 0.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER currentPeriod(1), lastPeriod(2)  

atmVcPMQoSCLR 1.3.6.1.4.1.164.12.2.1.2.2.7.1.3
Cell Loss Ratio counter for the reference period (atmVcPMQoSPeriodRef)- defined in accordance with I.356 , in %. The value will be multipuled by 100.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcPMQoSCER 1.3.6.1.4.1.164.12.2.1.2.2.7.1.4
Cell Error Ratio counter for the reference period (atmVcPMQoSPeriodRef) defined in accordance with I.356 , in %. The value will be multipuled by 100.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcPMQoSCMR 1.3.6.1.4.1.164.12.2.1.2.2.7.1.5
Cell Miss-insertion Ratio counter for the reference period (atmVcPMQoSPeriodRef) defined in accordance with I.356 , cells/sec .
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmVcShaperStatTable 1.3.6.1.4.1.164.12.2.1.2.2.8
The ATM VC shaper statistics table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmVcShaperStatEntry

atmVcShaperStatEntry 1.3.6.1.4.1.164.12.2.1.2.2.8.1
An entry in the ATM VC shaper statistics table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmVcShaperStatEntry  

atmVcShaperDiscarded 1.3.6.1.4.1.164.12.2.1.2.2.8.1.1
The number of Cells that were discarded in the shaper on that VCC due to buffer overflow. This counter counts till it reaches its MAX value (20 bits) and then rolls over.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

atmVcShaperOccupation 1.3.6.1.4.1.164.12.2.1.2.2.8.1.2
The number of Cells that are currently stored in the buffer. This parameter is limited to 20 bits.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmVcShaperMaxOccupation 1.3.6.1.4.1.164.12.2.1.2.2.8.1.3
The Maximum number of Cells that were stored in the buffer, since this VC was activated. This parameter is limited to 20 bits.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmVcShaperLevel 1.3.6.1.4.1.164.12.2.1.2.2.8.1.4
The occupation of the buffer according to a predefined threshold. empty - buffer is Empty full - buffer is Full below - buffer is Below the threshold above - buffer is Above the threshold. This is also the trigger to start EPD\PPD mechanism, if set for the VCC.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER empty(1), full(2), below(3), above(4)  

atmVcShaperEpdDropped 1.3.6.1.4.1.164.12.2.1.2.2.8.1.5
The number of Cells that were dropped in the shaper on that VCC due to EPD\PPD mechanism in the last second. This parameter is limited to 24 bits. Applicable for a EPD/PPD VC only.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

atmVcShaperTotalEpdDropped 1.3.6.1.4.1.164.12.2.1.2.2.8.1.6
The Total number of Cells that were dropped in the shaper on that VPC due to EPD\PPD mechanism in the last 15 minutes. This counter automatically reset itself every 15 minutes. Applicable for a EPD/PPD VC only.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

atmIntervalDateTable 1.3.6.1.4.1.164.12.2.1.3
The agent will keep in this group the date & time corresponding to each interval.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmIntervalDateEntry

atmIntervalDateEntry 1.3.6.1.4.1.164.12.2.1.3.1
The date & time for the given interval.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmIntervalDateEntry  

atmIntervalDateInterval 1.3.6.1.4.1.164.12.2.1.3.1.1
The interval number defining this entry.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..96  

atmIntervalDateDate 1.3.6.1.4.1.164.12.2.1.3.1.2
The date corresponding to this interval.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

atmIntervalDateTime 1.3.6.1.4.1.164.12.2.1.3.1.3
The time corresponding to this interval.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

atmNteSys 1.3.6.1.4.1.164.12.3.1
OBJECT IDENTIFIER    

atmNteSysConfig 1.3.6.1.4.1.164.12.3.1.1
OBJECT IDENTIFIER    

atmNteManagerTable 1.3.6.1.4.1.164.12.3.1.1.1
The Manager Table includes all the NMSs that receive traps from this agent. A single manager can receive traps on more than one PVC. The PVCs must be from the four allowed. The agent will set implicitly the correct ifIndex, VPI, VCI values to all relevant entries in the table when the user changes them for one of the PVCs.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmNteManagerEntry

atmNteManagerEntry 1.3.6.1.4.1.164.12.3.1.1.1.1
A single manager and the PVC for receiving traps.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmNteManagerEntry  

atmNteManagerIP 1.3.6.1.4.1.164.12.3.1.1.1.1.1
The IP address of the NMS.
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

atmNteManagerPvc 1.3.6.1.4.1.164.12.3.1.1.1.1.2
A PVC index. The range is 1..8. There are four PVCs on the User Port and four PVCs on the Network Port. The default VPI, VCI values are specified below.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmNteManagerIfIndex 1.3.6.1.4.1.164.12.3.1.1.1.1.3
The ATM interface index of the management port.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

atmNteManagerVpi 1.3.6.1.4.1.164.12.3.1.1.1.1.4
The VPI of the management VCL. Default: 0.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

atmNteManagerVci 1.3.6.1.4.1.164.12.3.1.1.1.1.5
The VCI of the management VCL. Defaults: 32,33,34,35.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

atmNteManagerTrapMask 1.3.6.1.4.1.164.12.3.1.1.1.1.6
The value of this attribute determines the type of traps the agent should mask and not send to this NMS. The value is differently determined for different products. There are mainly two methods: - an integer number, specifying the traps' severity. - a sum of 2**n, where n is a bit assigned to a certain masked trap group. User should consult the product specification, to find out the method employed.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

atmNteManagerRowStatus 1.3.6.1.4.1.164.12.3.1.1.1.1.7
Creation/Deletion of rows in the table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

atmNteManagerNextHop 1.3.6.1.4.1.164.12.3.1.1.1.1.8
This parameter is relevant to Ethernet out of band host only (PVC=10). The Next Hop IP address of the entry route.
Status: current Access: read-create
OBJECT-TYPE    
  IpAddress  

atmNteManagerVlanSupport 1.3.6.1.4.1.164.12.3.1.1.1.1.9
VLAN support (Tagging). no - No support to VLAN. yes - 4 VLAN bytes will be added to the frame.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

atmNteManagerVlanIdentifier 1.3.6.1.4.1.164.12.3.1.1.1.1.10
VLAN ID. Range is 0..4095.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

atmNteManagerVlanFramePriority 1.3.6.1.4.1.164.12.3.1.1.1.1.11
VLAN Frame priority.Range is 0..7.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

atmNteManagerAlarmTrapMask 1.3.6.1.4.1.164.12.3.1.1.1.1.12
The value of this object determines the alarm traps that the agent should mask and not send to this NMS. The value is an Octet String, where each bit is assigned to a certain trap. If the bit = 1, the trap will be masked. If the bit = 0, the trap will not be masked. More details on the masked traps exist in the product specification. For products that do not mask specific traps, the value of the bits will be 0.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING  

atmNteManagerConfigPorts 1.3.6.1.4.1.164.12.3.1.1.1.1.13
This variable defines from which port/s this manager can configure the device. For IPmux 11 the value of this variable will be according to the ports combination: Network =1 User1=2 User2=4 (For Example: All ports = 7).
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

atmNteUPLTCR 1.3.6.1.4.1.164.12.3.1.1.2
The Unacceptable ES Limit threshold for Performance Management.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmNteDPLTCR 1.3.6.1.4.1.164.12.3.1.1.3
The Degraded ES Limit threshold for Performance Management.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmNteSysLogClearAll 1.3.6.1.4.1.164.12.3.1.1.4
Setting the variable to clear(3) removes all entries in the Log Buffer of the agent. The agent will immediately reset the variable to off(2).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), clear(3)  

atmNteUSESLTCR 1.3.6.1.4.1.164.12.3.1.1.5
The Unacceptable SES Limit threshold for Performance Management.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmNteDSESLTCR 1.3.6.1.4.1.164.12.3.1.1.6
The Degraded ES Limit threshold for Performance Management.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmNteProtection 1.3.6.1.4.1.164.12.3.1.1.8
OBJECT IDENTIFIER    

atmNteProtectionMode 1.3.6.1.4.1.164.12.3.1.1.8.1
Protection Mode. MspOn - Multiplex section protection. pathOn - High order path protection. mspUniOn - Multiplex section Uni-directional protection. mspOneToN - Multiplex section protection.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(1), mspOn(2), pathOn(3), mspUniOn(4), mspOneToN(5)  



atmNteConfOam 1.3.6.1.4.1.164.12.3.1.1.9
OBJECT IDENTIFIER    

atmNteConfOamSupport 1.3.6.1.4.1.164.12.3.1.1.9.1
OAM support mode, which determines the device location in a segment wise.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER intermediate(1), segmentTermination(2), endToEndTermination(3), vpEndToEndVcSegment(4)  

atmNteConfOamTransmission 1.3.6.1.4.1.164.12.3.1.1.9.2
OBJECT IDENTIFIER    

atmNteConfOamAIS 1.3.6.1.4.1.164.12.3.1.1.9.2.1
Defines if a F4 segment OAM cell is transmitted due to problems in the other port, i.e. physical layer alarm or F4 defect. This is valid only when the ACE101 has ATM UNI interfaces in both sides and is configured for 'Non-Intrusive' mode. none - AIS is not sent to any of the ports. user - F4 AIS will be sent toward the user when defect is detected in the network port. network - F4 AIS will be sent toward the network when defect is detected in the user port. both - F4 AIS will be sent toward the network when defect is detected in the user port and toward the user when defect is detected in the network port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), user(2), network(3), both(4)  

atmNteConfOamRDI 1.3.6.1.4.1.164.12.3.1.1.9.2.2
Defines if an F4 OAM RDI cell is transmitted due to physical layer problems in the port (in addition to F4 RDI cells transmitted due to ATM layer problems). The type of F4 RDI (Segment or End-to-End) is according to the ACE-101 OAM mode. For example, If it is enabled for Network port, then physical layer defect will initiate the transmission of F4 RDI cell back to the trunk.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), user(2), network(3), both(4)  

atmNteConfOamAddressing 1.3.6.1.4.1.164.12.3.1.1.9.3
OBJECT IDENTIFIER    

atmNteConfLoopbackAddMode 1.3.6.1.4.1.164.12.3.1.1.9.3.1
Loopback addressing mode. on - will enable loopback addressing. off - will disable loopback addressing.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

atmNteConfLoopbackSourceAdd 1.3.6.1.4.1.164.12.3.1.1.9.3.2
Loopback source address. This field is relevant when atmNteConfOamAddMode is on.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(2..20)  

atmNteConfOamIfTable 1.3.6.1.4.1.164.12.3.1.1.9.4
OAM support per ATM interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmNteConfOamIfEntry

atmNteConfOamIfEntry 1.3.6.1.4.1.164.12.3.1.1.9.4.1
.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmNteConfOamIfEntry  

atmNteConfOamIfAisRdi 1.3.6.1.4.1.164.12.3.1.1.9.4.1.1
This parameter controls the generation of F4/F5 AIS and RDI due to lower order problems such as physical layer problems. For AIS: Defines if F4/F5 AIS cell is transmitted due to problems such as physical layer alarm or F4/F5 defect. This is applicable for all ports . off - Problems in this port will not trigger F4/F5 AIS transmition to the ajacent port (e.g. from USER to NETWORK) of a VPC/VCC. on - Problems in this port will trigger F4/F5 AIS transmition to the ajacent port (e.g. from USER to NETWORK) of a VPC/VCC. For RDI: Defines if F4/F5 RDI cell will be transmitted due to physical layer problems in that port (in addition to F4/F5 RDI cells transmitted due to ATM layer problems). For example, If it is enabled for Network port, then physical layer defect will initiate the transmission of F4/F5 RDI cell back to the trunk. The type of F4/F5 (Segment or End-to-End) is according to the configuration of the VPC/VCC.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

atmNteConfCAC 1.3.6.1.4.1.164.12.3.1.1.10
OBJECT IDENTIFIER    

atmNteConfCACMode 1.3.6.1.4.1.164.12.3.1.1.10.1
CAC support mode. For ACE2002, the following are the applicable values: disable(1), enable(2), 10 - 1000.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

atmNteHostIfTable 1.3.6.1.4.1.164.12.3.1.1.11
Host IP interface table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmNteHostIfEntry

atmNteHostIfEntry 1.3.6.1.4.1.164.12.3.1.1.11.1
.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmNteHostIfEntry  

atmNteHostPvcIndex 1.3.6.1.4.1.164.12.3.1.1.11.1.1
A PVC index. The range is 1..8. There are four PVCs on the User Port and four PVCs on the Network Port.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmNteHostIP 1.3.6.1.4.1.164.12.3.1.1.11.1.2
The host interface IP address.
Status: current Access: read-create
OBJECT-TYPE    
  IpAddress  

atmNteHostMask 1.3.6.1.4.1.164.12.3.1.1.11.1.3
The host interface subnet mask.
Status: current Access: read-create
OBJECT-TYPE    
  IpAddress  

atmNteHostAtmIfIndex 1.3.6.1.4.1.164.12.3.1.1.11.1.4
ATM interface index. Will be 1 for user port, and 2 for network port.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

atmNteHostVpi 1.3.6.1.4.1.164.12.3.1.1.11.1.5
VPI of the PVC connected to that host interface.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

atmNteHostVci 1.3.6.1.4.1.164.12.3.1.1.11.1.6
VCI of the PVC connected to that host interface.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

atmNteHostRowStatus 1.3.6.1.4.1.164.12.3.1.1.11.1.7
Creation/Deletion of rows in the table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

atmNteHostRdnVpi 1.3.6.1.4.1.164.12.3.1.1.11.1.8
The VPI of the redundant management VCL. This parameter is applicable only if atmNteRdnManagement=enable(3).
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

atmNteHostRdnVci 1.3.6.1.4.1.164.12.3.1.1.11.1.9
The VCI of the redundant management VCL. This parameter is applicable only if atmNteRdnManagement=enable(3).
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

atmNteHostDefaultNextHop 1.3.6.1.4.1.164.12.3.1.1.11.1.10
The host interface Default Next Hop address. This address will be used as default next hop for every Bundle mapped to this Host.
Status: current Access: read-create
OBJECT-TYPE    
  IpAddress  

atmNteHostVlanTagging 1.3.6.1.4.1.164.12.3.1.1.11.1.11
VLAN Tag support. no - No support to VLAN. yes - 4 VLAN bytes will be added to each frame connected to this Host.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER no(2), yes(3)  

atmNteHostDefaultVlanID 1.3.6.1.4.1.164.12.3.1.1.11.1.12
Default VLAN ID of this Host.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

atmNteHostDefaultVlanPriority 1.3.6.1.4.1.164.12.3.1.1.11.1.13
Default VLAN priority for this Host.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

atmNteShaperMode 1.3.6.1.4.1.164.12.3.1.1.12
Shaper Mode. vpInbandMng - Vcc within a Vp for management.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER normal(1), group(2), aggregate(3), vpInbandMng(4)  

atmNteOutputRate 1.3.6.1.4.1.164.12.3.1.1.13
Aggregate shaping output rate in Cells per Seconds units. Default value is the Network port rate.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmNteTosMode 1.3.6.1.4.1.164.12.3.1.1.14
TOS Mode.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), disable(2), enable(3)  

atmNteTosMask 1.3.6.1.4.1.164.12.3.1.1.15
This parameter determines the seqence of bits that will be used for TOS. For ACE101 this parameter is applicable only if atmNteTosMode = enable. Valid only for IP-TOS process.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1)  

atmNteTosHighPriority 1.3.6.1.4.1.164.12.3.1.1.16
Priorities options are High or Low. High priority will be represented by bit = 1. Low priority will be represented by bit = 0. Each TOS value will be represented by the bit location. For example, the string for TOS 2, 9, 15 with High priority, will be: |0000 0000|... ...|0000 0000|1000 0010|0000 0100| ...98 7654 3210 (Bit #) 8 ... 3 2 1 (Byte #).
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8)  

atmNtePlugAndPlayActivity 1.3.6.1.4.1.164.12.3.1.1.17
Activity control for Manager Plug And Play. disable - disable the feature. offline - Automatic learn IP address into offline memory. online - Automatic learn IP address into online memory.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), offline(2), online(3)  

atmNteSlotUsage 1.3.6.1.4.1.164.12.3.1.1.18
Applicable to ace2002. Slot 2 might be configured as user slot or as network slot.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), user(2), network(3)  

atmNteConnectionsMaxNumber 1.3.6.1.4.1.164.12.3.1.1.19
The MAX number of connections supported by system. Setting this parameter will affect the number of MAX intervals supported. This parameter will affect the system only after reset. Changing this parameter from high value to a low value, will be accepted by agent only if the actual used connection <= the desired connection Max number. Applicable to ace2002.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), max1024(2), max2048(3)  

atmNteDefaultVpi 1.3.6.1.4.1.164.12.3.1.1.20
Default Vpi for management.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmNteDefaultVci 1.3.6.1.4.1.164.12.3.1.1.21
Default Vci for management.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmNteReservedVpi 1.3.6.1.4.1.164.12.3.1.1.22
Internal use VPI, where shaperMode=vpInbandMng.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..255  

atmNteRdnManagement 1.3.6.1.4.1.164.12.3.1.1.23
The redundancy management status.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER disabled(2), enabled(3)  

atmNtePlugAndPlayIfIndex 1.3.6.1.4.1.164.12.3.1.1.24
The ifIndex of the Plug and Play VCC.
Status: current Access: read-write
OBJECT-TYPE    
  InterfaceIndex  

atmNteLoopbackTimeout 1.3.6.1.4.1.164.12.3.1.1.25
The Loopback state timeout in minutes. A value of zero means no timeout (for ever). Default is 5 min.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmNteOamTable 1.3.6.1.4.1.164.12.3.1.1.26
This table is a static table, which is created by agent once upon initialization. The created entries are actually, only the supported OAM features. This table enables addition of new features by adding new entries rather than adding scalar parameters. An OAM feature is defined by the indexes values combination.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmNteOamEntry

atmNteOamEntry 1.3.6.1.4.1.164.12.3.1.1.26.1
An entry in the OAM table. Each entry in this table will indicate a special OAM.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmNteOamEntry  

atmNteOamMode 1.3.6.1.4.1.164.12.3.1.1.26.1.1
The OAM cell path. endToEnd(1) - the entire path.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER endToEnd(1)  

atmNteOamCellType 1.3.6.1.4.1.164.12.3.1.1.26.1.2
This object indicates a unique Indication Signal. aisAndRdi(1) - Alarm Indication Signal (AIS) and Remote Defect Indication (RDI) cell. loopback(2) - Loopback cell.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER aisAndRdi(1), loopback(2)  

atmNteOamLevel 1.3.6.1.4.1.164.12.3.1.1.26.1.3
The level of the OAM cell. -- f4 (2) - VP level, f5 (3) - VC level.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER f5(3)  

atmNteOamEnable 1.3.6.1.4.1.164.12.3.1.1.26.1.4
This parameter determines if the specified OAM cells will be enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(2), enable(3)  

atmNteDefaultLoopbackThreshold 1.3.6.1.4.1.164.12.3.1.1.27
The Default OAM Loopback Failure Threshold value that will be used for configuration.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmNteMaxBurstSize 1.3.6.1.4.1.164.12.3.1.1.28
The Maximum allowed burst size (cell units). This object is applicable for each Physical port.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmNteGranularityFactor 1.3.6.1.4.1.164.12.3.1.1.29
This parameter affects the granularity of the guaranteed Rate (SCR+MCR) in spaced connection (cell/sec units). It is also defines the minimum guaranteed rate in spaced connection.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmNteTotalInputRate 1.3.6.1.4.1.164.12.3.1.1.30
This parameter indicates the total input rate of the device in cells/sec.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmNteTotalOutputRate 1.3.6.1.4.1.164.12.3.1.1.31
This parameter indicates the total output rate of the device in cells/sec.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmAlarmForwardingTable 1.3.6.1.4.1.164.12.3.1.1.32
The Alarm Forwarding Mechanism will be operated for this table entries.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmAlarmForwardingEntry

atmAlarmForwardingEntry 1.3.6.1.4.1.164.12.3.1.1.32.1
Each entry in this table is a pair of ports that the Alarm Forwarding Mechanism is determined for.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmAlarmForwardingEntry  

atmAlarmForwardingFailPort 1.3.6.1.4.1.164.12.3.1.1.32.1.1
An Index of the port on which a fail occurs.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

atmAlarmForwardingToPort 1.3.6.1.4.1.164.12.3.1.1.32.1.2
An Index of the port that will be affected upon the failure of the atmAlarmForwardingFailPort.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

atmAlarmForwardingRowStatus 1.3.6.1.4.1.164.12.3.1.1.32.1.3
Creation/Deletion of rows in the table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

atmAlarmForwardingFailureLevel 1.3.6.1.4.1.164.12.3.1.1.32.1.4
This parameter determines the level of failure that will operate the Alarm Forwarding Mechanism.
Status: current Access: read-create
OBJECT-TYPE    
  BITS physical(0), atm(1)  

atmAlarmForwardingRecoveryMode 1.3.6.1.4.1.164.12.3.1.1.32.1.5
This parameter determines the Recovery Mode. manual - The user should stop the RDI transmission by using the atmAlarmForwardingRecoveryCommand. automatic - The RDI transmission will be automatically stopped upon atmAlarmForwardingFailPort recovery.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER manual(1), automatic(2)  

atmAlarmForwardingRecoveryCommand 1.3.6.1.4.1.164.12.3.1.1.32.1.6
This parameter is a command. It is applicable when atmAlarmForwardingRecoveryMode = manual. on - Will stop the RDI transmission. After setting to 'On' the agent will set this parameter back to 'Off'.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER off(2), on(3)  

atmSysConfigCellTest 1.3.6.1.4.1.164.12.3.1.1.33
OBJECT IDENTIFIER    

atmSysConfigCellTestPort 1.3.6.1.4.1.164.12.3.1.1.33.1
An Index of the port on which the cell test will be sent.
Status: current Access: read-write
OBJECT-TYPE    
  InterfaceIndex  

atmSysConfigCellTestVpi 1.3.6.1.4.1.164.12.3.1.1.33.2
The VPI on which the cell test will be sent.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmSysConfigCellTestVci 1.3.6.1.4.1.164.12.3.1.1.33.3
The VCI on which the cell test will be sent.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmSysConfigCellTestPti 1.3.6.1.4.1.164.12.3.1.1.33.4
The cell type.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER user(1), oamSegment(2), oamEndToEnd(3)  

atmSysConfigCellTestClp 1.3.6.1.4.1.164.12.3.1.1.33.5
The type of the Cell.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER clp0(1), clp1(2)  

atmSysConfigCellTestOamType 1.3.6.1.4.1.164.12.3.1.1.33.6
The OAM type of the Cell. This object is applicable if atmSysConfigCellTestPti = oamSegment/oamEndToEnd .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ais(1), rdi(2), cc(3), lb(4)  

atmSysConfigCellTestPayload 1.3.6.1.4.1.164.12.3.1.1.33.7
The payload of the cell. For OAM cell the payload is set automatically to 6A.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1)  

atmSysConfigCellTestQuantity 1.3.6.1.4.1.164.12.3.1.1.33.8
Quantity of cells to send.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..10000  

atmSysConfigCellTestSendCmd 1.3.6.1.4.1.164.12.3.1.1.33.9
Setting the variable to send(3) perfroms cell test. The agent will immediately reset the variable to off(2).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), send(3)  

atmVpCrossConnectExtenTable 1.3.6.1.4.1.164.12.3.1.1.34
An extension to the ATM VP Cross Connect table (RFC2515 - atmVpCrossConnectTable).
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmVpCrossConnectExtenEntry

atmVpCrossConnectExtenEntry 1.3.6.1.4.1.164.12.3.1.1.34.1
An entry in the table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmVpCrossConnectExtenEntry  

atmVpCrossConnectName 1.3.6.1.4.1.164.12.3.1.1.34.1.1
The Connection's name.
Status: current Access: read-create
OBJECT-TYPE    
  SnmpAdminString Size(1..64)  

atmVcCrossConnectExtenTable 1.3.6.1.4.1.164.12.3.1.1.35
An extension to the ATM VC Cross Connect table (RFC2515 - atmVcCrossConnectTable).
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmVcCrossConnectExtenEntry

atmVcCrossConnectExtenEntry 1.3.6.1.4.1.164.12.3.1.1.35.1
An entry in the table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmVcCrossConnectExtenEntry  

atmVcCrossConnectName 1.3.6.1.4.1.164.12.3.1.1.35.1.1
The Connection's name.
Status: current Access: read-create
OBJECT-TYPE    
  SnmpAdminString Size(1..64)  

atmNteSysInfo 1.3.6.1.4.1.164.12.3.1.2
OBJECT IDENTIFIER    

atmNteIdTable 1.3.6.1.4.1.164.12.3.1.2.1
The IDs of the cards and of the system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmNteIdEntry

atmNteIdEntry 1.3.6.1.4.1.164.12.3.1.2.1.1
.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmNteIdEntry  

atmNteIdIndex 1.3.6.1.4.1.164.12.3.1.2.1.1.1
An Index of the Unit ID table. The following units have IDs in this table: 1 - System 2 - ATM Board 3 - User Card 4 - Trunk 1 card 5 - Trunk 2 card 6 - Shaper 7 - Clock Unit 8 - Slot 1 card 9 - Slot 2 card 10 - Slot 3 card 11 - Slot 4 card 12 - Fan1. 13 - Fan2.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmNteUnitId 1.3.6.1.4.1.164.12.3.1.2.1.1.2
The ID of the Unit. For index = 6, the id will describe the validity of a shaper in the system: 0 - Shaper Not exist 1 - Shaper exist. For index = 7, the id will describe the validity of a clock in the system: 0 - Clock Not exist 1 - Clock exist. 2- Clock exist but failed. For index = 12,13 the id will describe the functionality of a FAN1 : 0 - OK 1 - Failed.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmNteUnitVersion 1.3.6.1.4.1.164.12.3.1.2.1.1.3
Hardware and Software version of the module.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

atmNteCardType 1.3.6.1.4.1.164.12.3.1.2.1.1.4
The card type.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), sc13mR155(2), st13sR155(3), st13lR155(4), utpR155(5), cxBncR155(6), e3(7), t3(8), e1(9), e1Ltu(10), fc13lR155(11), fc13lhR155(12), fc15lhR155(13), fc13lE3(14), fc13lhE3(15), fc15lhE3(16), fc13lT3(17), fc13lhT3(18), fc15lhT3(19), t1(20), eth(21), ethE1CesBnc(22), ethE1CesRj45(23), ethT1CesRj45(24), e1CesRj45(25), e1CesBnc(26), t1CesRj45(27), e14Ces(28), e14CesRj45(29), t14CesRj45(30), hdlc4port(31), hdlcE14CesBnc(32), hdlcE14CesRj45(33), hdlcT14CesRj45(34), e1Rj45(35), e1Bnc(36), ethE14CesBnc(37), ethE14CesRj45(38), ethT14CesRj45(39), hdlc1portHssi(40), hdlcHssiE14CesBnc(41), hdlcHssiE14CesRj45(42), hdlcHssiT14CesRj45(43), e14ImaRj45(44), e14ImaBnc(45), t14ImaRj45(46), ethE3CesBnc(47), ethT3CesBnc(48), smSf1R155(49), smSf2R155(50), sc13sR155(51), sc13lR155(52), utp25(53), sc13lhR155(54), sc15lhR155(55), sc13ljR155(56), sc13lhjR155(57), sc15lhjR155(58), e18Ces(59), e18CesRj45(60), t18CesRj45(61), sc13mR622(62), sc13lR622(73), sc13lhR622(74), sc15lhR622(75), fr4Port(76), t3j(77), fr1Port(78), hdlc1Port(79), sc13mR155D(80), sc13lR155D(81), fc13lR155D(82), st13lR155D(83), sc13lhR155D(84), fc13lhR155D(85), st13lhR155D(86), e18ImaBnc(87), e18ImaRj45(88), t18ImaRj45(89), lanUtpE(90), lanLc13lE(91), lanLc13mE(92), e14ImaRj45CfgMode(93), e14ImaBncCfgMode(94), t14ImaRj45CfgMode(95), sc13mR155R(96), sc13lR155R(97), fc13lR155R(98), st13lR155R(99), sc13lhR155R(100), fc13lhR155R(101), st13lhR155R(102), fEthUtpD(103), fEthSmD(104), fEthMmD(105), e14CesRj45Unbal(106), sc13mR155n(107), sc13lR155n(108), sc13lhR155n(109), sc15lhR155n(110), fc13lR155n(111), fc13lhR155n(112), fc15lhR155n(113), st13lR155n(114), lanUtp(115), lanLc13l(116), lanLc13m(117), e1FrHdlc(118), e1FrHdlcUnbal(119), t1FrHdlc(120), channelizedT3(121), fc15lhR155D(122), sc15lhR155D(123), smSf1R155D(124), smSf2R155D(125), smSf3R155D(126), fc15lhR155R(127), sc15lhR155R(128), smSf1R155R(129), smSf2R155R(130), smSf3R155R(131), st13lhR155n(132), smSf1R155n(133), smSf2R155n(134), smSf3R155n(135), t18CesNg(136), e18CesUnbalNg(137), e18CesBalNg(138), t14CesNg(139), e14CesUnbalNg(140), e14CesBalNg(141), t18ImaUniNg(142), e18ImaUniUnbalNg(143), e18ImaUniBalNg(144), t14ImaUniNg(145), e14ImaUniUnbalNg(146), e14ImaUniBalNg(147), t1Ces(148), e1CesUnbal(149), e1CesBal(150), empty(255)  

atmNteCardStatus 1.3.6.1.4.1.164.12.3.1.2.1.1.5
Status of the card in the selected slot. notActive - Connections are in NotReady state. No configuration is available for the card. The access to the card HW is blocked. This state is relevant for an extracted card, and for a case in which the card was deactivated. active - The module installed and functions. A card that in this state can be configured. inProgress - The status during proccessing of a command from atmNteCardCmd. empty - No information is valid for the selected slot. This status is relevant to a case in which the card configaration was deleted, or in case in which a slot was empty since the device startup.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), notActive(2), active(3), inProgress(4), empty(5)  

atmNteCardCmd 1.3.6.1.4.1.164.12.3.1.2.1.1.6
Command on the card that is installed in the selected slot. The commands are applicable according to the value of atmNteCardStatus. See the specification document for details. deleteConfig - Deletes the card configuration. deactivate - All the connections state will be changed to NotReady. The card configuration will be blocked. activate - Does the same as done upon card insertion: Initiates the relevant parameters, activates the physical layer, ATM layer and logical layer.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), deleteConfig(2), deactivate(3), activate(4)  

atmSysPSunits 1.3.6.1.4.1.164.12.3.1.2.2
The number of power supply units.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmSysPSunitsInUse 1.3.6.1.4.1.164.12.3.1.2.3
The main power supply in this unit.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER ps1(2), ps2(3)  

atmSysFanUnits 1.3.6.1.4.1.164.12.3.1.2.4
The number of fan units.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmSysNetPrts 1.3.6.1.4.1.164.12.3.1.2.5
The number of network ports.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmSysNetPrtInUse 1.3.6.1.4.1.164.12.3.1.2.6
The network port in use.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER trunk1(2), trunk2(3)  

atmNteBridgingMode 1.3.6.1.4.1.164.12.3.1.2.7
Bridging mode can be one of the following: ATM <> Ethernet - Bridging is between the Ethernet port and the ATM port (there is no bridging between VCs). ATM <> Ethernet + ATM - Bridging is done both between the Ethernet port and the ATM port and also between VCs.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER accessOnly(1), accessAndSwitching(2)  

atmSysStats 1.3.6.1.4.1.164.12.3.1.2.8
OBJECT IDENTIFIER    

atmSysCurrentCdc 1.3.6.1.4.1.164.12.3.1.2.8.1
Seconds in which cells dropped was occured in the current 15 minutes interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmSysIntervalTable 1.3.6.1.4.1.164.12.3.1.2.8.2
The system level Interval table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmSysIntervalEntry

atmSysIntervalEntry 1.3.6.1.4.1.164.12.3.1.2.8.2.1
.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmSysIntervalEntry  

atmSysIntervalNumber 1.3.6.1.4.1.164.12.3.1.2.8.2.1.1
A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..96  

atmSysIntervalCdc 1.3.6.1.4.1.164.12.3.1.2.8.2.1.2
Seconds in which cells dropped was occured in 15 minutes interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmNteEventType 1.3.6.1.4.1.164.12.3.1.2.9
This parameter identifies the event. On - the problem exist. Off - the problem not exist. InvalidLogin - Invalid login on local console. CorrectLogin - Successful login operation.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER ps1NotActive(3), ps1Active(4), ps2NotActive(5), ps2Active(6), heatAlarmOff(7), heatAlarmOn(8), inputAlarm1Off(9), inputAlarm1On(10), inputAlarm2Off(11), inputAlarm2On(12), inputAlarm3Off(13), inputAlarm3On(14), inputAlarm4Off(15), inputAlarm4On(16), fan1Ok(17), fan1Fail(18), fan2Ok(19), fan2Fail(20), invalidLogin(21), validLogin(22), powerFailure(23), writeToFlashFailure(24)  

atmNteIntervalMaxNumber 1.3.6.1.4.1.164.12.3.1.2.10
The MAX number of connections intervals supported by system. This parameter value is a function of atmNteConnectionsMaxNumber parameter. This parameter should affect the threshold values selected by user. Applicable to ace2002.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..96  

atmNteAlarmType 1.3.6.1.4.1.164.12.3.1.2.11
This object specifies the type of the alarm.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), ais(2), rdi(3), continuityLoss(4), loopback(5)  

atmNteLevel 1.3.6.1.4.1.164.12.3.1.2.12
This object specifies the ATM level.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER vp(2), vc(3)  

atmNteConnectionsNumber 1.3.6.1.4.1.164.12.3.1.2.13
This object specifies a quantity of connections.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmNteTotalLb 1.3.6.1.4.1.164.12.3.1.2.14
This parameter counts the total number of end-points that were configured with Loopback (LB).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmNteTotalCc 1.3.6.1.4.1.164.12.3.1.2.15
This parameter counts the total number of end-points that were configured with Continuity Check (CC).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmNteTotalPm 1.3.6.1.4.1.164.12.3.1.2.16
This parameter counts the total number of end-points that were configured with PM.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmNteLoopback 1.3.6.1.4.1.164.12.3.2.2
OBJECT IDENTIFIER    

atmLoopbackVpTable 1.3.6.1.4.1.164.12.3.2.2.1
This table contains parameters for an OAM VP loopback test.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmLoopbackVpEntry

atmLoopbackVpEntry 1.3.6.1.4.1.164.12.3.2.2.1.1
An entry in table atmLoopbackVpTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmLoopbackVpEntry  

atmLoopbackVpIfIndex 1.3.6.1.4.1.164.12.3.2.2.1.1.1
The interface index of the ATM layer.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLoopbackVpVpi 1.3.6.1.4.1.164.12.3.2.2.1.1.2
The VPI of the OAM VPL.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLoopbackVpOperStatus 1.3.6.1.4.1.164.12.3.2.2.1.1.3
-noActive(1) means that the loopback test has not been activated for this VP. -inProgress(2) means that the test has been activated and there is currently no problem. -failed(3) means there was problem during the test or after having stopped it -endSuccessfully(4) means that the test was stopped and all was OK.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER noActive(1), inProgress(2), failed(3), endSuccessfully(4)  

atmLoopbackVpCDV 1.3.6.1.4.1.164.12.3.2.2.1.1.4
Cell Delay Variation for this sampling.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLoopbackVpAverageDelay 1.3.6.1.4.1.164.12.3.2.2.1.1.5
Average delay without including lost cells.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLoopbackVpMaxDelay 1.3.6.1.4.1.164.12.3.2.2.1.1.6
Maximum delay without including lost cells.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLoopbackVpMinDelay 1.3.6.1.4.1.164.12.3.2.2.1.1.7
Minimum delay.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLoopbackVpErrSessions 1.3.6.1.4.1.164.12.3.2.2.1.1.8
Errored Sessions. Will be updated once in 5 seconds.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLoopbackVcTable 1.3.6.1.4.1.164.12.3.2.2.2
This table contains parameters for an OAM VC loopback test.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmLoopbackVcEntry

atmLoopbackVcEntry 1.3.6.1.4.1.164.12.3.2.2.2.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmLoopbackVcEntry  

atmLoopbackVcIfIndex 1.3.6.1.4.1.164.12.3.2.2.2.1.1
The interface index of the ATM layer.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLoopbackVcVpi 1.3.6.1.4.1.164.12.3.2.2.2.1.2
The VPI of the OAM VCL.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLoopbackVcVci 1.3.6.1.4.1.164.12.3.2.2.2.1.3
The VCI of the OAM VCL.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLoopbackVcOperStatus 1.3.6.1.4.1.164.12.3.2.2.2.1.4
-noActive(1) means that the loopback test has not been activated for this VP. -inProgress(2) means that the test has been activated and there is currently no problem. -failed(3) means there was problem during the test or after having stopped it -endSuccessfully(4) means that the test was stopped and all was OK.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER noActive(1), inProgress(2), failed(3), endSuccessfully(4)  

atmLoopbackVcCDV 1.3.6.1.4.1.164.12.3.2.2.2.1.5
Cell Delay Variation for this sampling.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLoopbackVcAverageDelay 1.3.6.1.4.1.164.12.3.2.2.2.1.6
Average delay without including lost cells.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLoopbackVcMaxDelay 1.3.6.1.4.1.164.12.3.2.2.2.1.7
The maximum delay without including lost cells.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLoopbackVcMinDelay 1.3.6.1.4.1.164.12.3.2.2.2.1.8
The minimum delay.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLoopbackVcErrSessions 1.3.6.1.4.1.164.12.3.2.2.2.1.9
Errored Sessions. Will be updated once in 5 seconds.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLoopbackVpIvlTable 1.3.6.1.4.1.164.12.3.2.2.3
This table contains parameters for an OAM VP loopback test, according interval number.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmLoopbackVpIvlEntry

atmLoopbackVpIvlEntry 1.3.6.1.4.1.164.12.3.2.2.3.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmLoopbackVpIvlEntry  

atmLoopbackVpIvlIfIndex 1.3.6.1.4.1.164.12.3.2.2.3.1.1
The interface index of the ATM layer.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLoopbackVpIvlVpi 1.3.6.1.4.1.164.12.3.2.2.3.1.2
The VPI of the OAM VPL.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLoopbackVpIvlIvl 1.3.6.1.4.1.164.12.3.2.2.3.1.3
The relevant interval number.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..96  

atmLoopbackVpIvlOperStatus 1.3.6.1.4.1.164.12.3.2.2.3.1.4
-noActive(1) means that the loopback test has not been activated for this VP during this interval. -inProgress(2) has no meaning for an ended interval. -failed(3) means there was problem during the test or after having stopped it -endSuccessfully(4) means that the test was OK.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER noActive(1), inProgress(2), failed(3), endSuccessfully(4)  

atmLoopbackVpIvlCDV 1.3.6.1.4.1.164.12.3.2.2.3.1.5
Cell Delay Variation for this interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLoopbackVpIvlAverageDelay 1.3.6.1.4.1.164.12.3.2.2.3.1.6
Average delay without including lost cells for this interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLoopbackVpIvlMaxDelay 1.3.6.1.4.1.164.12.3.2.2.3.1.7
The maximum delay without including lost cells for this interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLoopbackVpIvlMinDelay 1.3.6.1.4.1.164.12.3.2.2.3.1.8
The minimum delay for this interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLoopbackVpIvlErrSessions 1.3.6.1.4.1.164.12.3.2.2.3.1.9
Errored Sessions. Will be updated once in 5 seconds.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLoopbackVcIvlTable 1.3.6.1.4.1.164.12.3.2.2.4
This table contains parameters for an OAM VC loopback test.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmLoopbackVcIvlEntry

atmLoopbackVcIvlEntry 1.3.6.1.4.1.164.12.3.2.2.4.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmLoopbackVcIvlEntry  

atmLoopbackVcIvlIfIndex 1.3.6.1.4.1.164.12.3.2.2.4.1.1
The interface index of the ATM layer.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLoopbackVcIvlVpi 1.3.6.1.4.1.164.12.3.2.2.4.1.2
The VPI of the OAM VCL.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLoopbackVcIvlVci 1.3.6.1.4.1.164.12.3.2.2.4.1.3
The VCI of the OAM VCL.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLoopbackVcIvlIvl 1.3.6.1.4.1.164.12.3.2.2.4.1.4
The relevant interval number.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..96  

atmLoopbackVcIvlOperStatus 1.3.6.1.4.1.164.12.3.2.2.4.1.5
-noActive(1) means that the loopback test has not been activated for this VC during this interval. -inProgress(2) has no meaning per interval. -failed(3) means there was problem for this test during this interval. -endSuccessfully(4) means that the test was OK.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER noActive(1), inProgress(2), failed(3), endSuccessfully(4)  

atmLoopbackVcIvlCDV 1.3.6.1.4.1.164.12.3.2.2.4.1.6
Cell Delay Variation for this interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLoopbackVcIvlAverageDelay 1.3.6.1.4.1.164.12.3.2.2.4.1.7
Average delay without including lost cells.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLoopbackVcIvlMaxDelay 1.3.6.1.4.1.164.12.3.2.2.4.1.8
The maximum delay without including lost cells.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLoopbackVcIvlMinDelay 1.3.6.1.4.1.164.12.3.2.2.4.1.9
The minimum delay.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmLoopbackVcIvlErrSessions 1.3.6.1.4.1.164.12.3.2.2.4.1.10
Errored Sessions. Will be updated once in 5 seconds.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmNtePM 1.3.6.1.4.1.164.12.3.2.3
OBJECT IDENTIFIER    

atmVpPmTable 1.3.6.1.4.1.164.12.3.2.3.1
This table contains parameters for VP performance monitoring.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmVpPmEntry

atmVpPmEntry 1.3.6.1.4.1.164.12.3.2.3.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmVpPmEntry  

atmVpPmIfIndex 1.3.6.1.4.1.164.12.3.2.3.1.1.1
The interface index of the ATM layer.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmVpPmVpi 1.3.6.1.4.1.164.12.3.2.3.1.1.2
The VPI of the Performance Monitoring VPL.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmVpPmAdminStatus 1.3.6.1.4.1.164.12.3.2.3.1.1.3
up(2) - Activate PM. down(3) - Deactivate PM. listenToActivationCells(4) - . originateActivationCells(5) - .
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER up(2), down(3), listenToActivationCells(4), originateActivationCells(5)  

atmVpPmDirection 1.3.6.1.4.1.164.12.3.2.3.1.1.4
The direction of PM.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER source(2), destination(3), bidirectional(4)  

atmVpPmBlockSize 1.3.6.1.4.1.164.12.3.2.3.1.1.5
Valid block sizes (in cells): 128, 256, 512, 1024, 2048, 4096, 8192, 16384, 32768.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

atmVpPmRowStatus 1.3.6.1.4.1.164.12.3.2.3.1.1.6
Creation/Deletion of rows in the table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

atmVpPmSink 1.3.6.1.4.1.164.12.3.2.3.1.1.7
off (1) - Deactivate PM. fwd (2) - Activate Forward PM only. fwdAndBwdReport(3) - Activate Forward PM and Backward reporting.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER off(1), fwd(2), fwdAndBwdReport(3)  

atmVpPmSource 1.3.6.1.4.1.164.12.3.2.3.1.1.8
off (1) - Deactivate PM. fwd (2) - Activate Forward PM only. fwdAndBwdReport(3) - Activate Forward PM and Backward reporting.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER off(1), fwd(2), fwdAndBwdReport(3)  

atmVcPmTable 1.3.6.1.4.1.164.12.3.2.3.2
This table contains parameters for VC performance monitoring.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmVcPmEntry

atmVcPmEntry 1.3.6.1.4.1.164.12.3.2.3.2.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmVcPmEntry  

atmVcPmIfIndex 1.3.6.1.4.1.164.12.3.2.3.2.1.1
The interface index of the ATM layer.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmVcPmVpi 1.3.6.1.4.1.164.12.3.2.3.2.1.2
The VPI of the Performance Monitoring VCL.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmVcPmVci 1.3.6.1.4.1.164.12.3.2.3.2.1.3
The VCI of the PM VCL.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmVcPmAdminStatus 1.3.6.1.4.1.164.12.3.2.3.2.1.4
up(2) - Activate PM. down(3) - Deactivate PM. listenToActivationCells(4) - . originateActivationCells(5) - .
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER up(2), down(3), listenToActivationCells(4), originateActivationCells(5)  

atmVcPmDirection 1.3.6.1.4.1.164.12.3.2.3.2.1.5
The direction of PM.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER source(2), destination(3), bidirectional(4)  

atmVcPmBlockSize 1.3.6.1.4.1.164.12.3.2.3.2.1.6
Valid block sizes (in cells): 128, 256, 512, 1024, 2048, 4096, 8192, 16384, 32768.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

atmVcPmRowStatus 1.3.6.1.4.1.164.12.3.2.3.2.1.7
Creation/Deletion of rows in the table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

atmVcPmSink 1.3.6.1.4.1.164.12.3.2.3.2.1.8
off (1) - Deactivate PM. fwd (2) - Activate Forward PM only. fwdAndBwdReport(3) - Activate Forward PM and Backward reporting.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER off(1), fwd(2), fwdAndBwdReport(3)  

atmVcPmSource 1.3.6.1.4.1.164.12.3.2.3.2.1.9
off (1) - Deactivate PM. fwd (2) - Activate Forward PM only. fwdAndBwdReport(3) - Activate Forward PM and Backward reporting.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER off(1), fwd(2), fwdAndBwdReport(3)  

atmNteMdl 1.3.6.1.4.1.164.12.3.3
OBJECT IDENTIFIER    

atmNteMdlConfig 1.3.6.1.4.1.164.12.3.3.1
OBJECT IDENTIFIER    

atmNteMdlConfigTable 1.3.6.1.4.1.164.12.3.3.1.1
Module configuration table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmNteMdlConfigEntry

atmNteMdlConfigEntry 1.3.6.1.4.1.164.12.3.3.1.1.1
There is an entry in this table just for those modules that have parameters that are relevant to module level only.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmNteMdlConfigEntry  

atmNteMdlSlotIndex 1.3.6.1.4.1.164.12.3.3.1.1.1.1
The slot number.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..4  

atmNteMdlPrtCpuSharing 1.3.6.1.4.1.164.12.3.3.1.1.1.2
This object lets the user decide what will be the CPU sharing between the ports of the module. This object is applicable for modules in which the same CPU handles the traffic of all ports. equal - All ports will have the same CPU resource. port1 - Port 1 will have higher priority than the other ports.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER equal(2), port1(3)  

atmNteMdlInputPriorityMechanism 1.3.6.1.4.1.164.12.3.3.1.1.1.3
This object allows the user to Enable/Disable the Input priority mechanism. This object is applicable for modules with more than one port, in which the total ports input may be greater than the port output. disabled - all LAN VCCs will be transmitted through the same queue (queue 1). Upon congestion frames will be dropped randomly. enabled - the user should configure each port/connection priority. Upon congestion frames will be dropped according to priority.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(2), enabled(3)  

atmGenSystem 1.3.6.1.4.1.164.12.2.2
OBJECT IDENTIFIER    

atmGenSysGen 1.3.6.1.4.1.164.12.2.2.1
OBJECT IDENTIFIER    

atmGenSysSelfTestTable 1.3.6.1.4.1.164.12.2.2.1.1
A table containing the results of the initial testing of the device.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmGenSysSelfTestEntry

atmGenSysSelfTestEntry 1.3.6.1.4.1.164.12.2.2.1.1.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmGenSysSelfTestEntry  

atmGenSysSelfTestIndex 1.3.6.1.4.1.164.12.2.2.1.1.1.1
A running index for the table.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmGenSysSelfTestResult 1.3.6.1.4.1.164.12.2.2.1.1.1.2
The results of the initial testing of the device.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

atmGenSysLogClearAll 1.3.6.1.4.1.164.12.2.2.1.2
Setting the variable to clear(3) removes all entries in the Log Buffer of the agent. The agent will immediately reset the variable to off(2).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), clear(3)  

atmGenSysLogTable 1.3.6.1.4.1.164.12.2.2.1.3
A copy of the log buffer.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmGenSysLogEntry

atmGenSysLogEntry 1.3.6.1.4.1.164.12.2.2.1.3.1
An entry in table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmGenSysLogEntry  

atmGenSysLogIndex 1.3.6.1.4.1.164.12.2.2.1.3.1.1
The index of the log buffer.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..2048  

atmGenSysLogMessage 1.3.6.1.4.1.164.12.2.2.1.3.1.2
The log buffer entry message text.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(80)  

atmGenSysSetDefaultConfg 1.3.6.1.4.1.164.12.2.2.1.4
When set to on(3), the agent will set all the configuration parameters to their default values. The variable is then reset to off(2) by the agent. The agent must be reset for the default configuration to apply.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

atmGenSysCxRefTable 1.3.6.1.4.1.164.12.2.2.1.5
A Cross Reference table. The table maintains an index of an object which is also the table index, and a counter that indicates how many times this object was referenced. When using this table for more than one referenced table, which uses the same range of indexes, then the index should be shifted by a unique offset per table. In ACE2002 this table is used for TD and for FR Desc. Thus, the index for FR Descriptor is: FR Descriptor index + offset. The offset is described in the ACE2002 NMS SRS.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmGenSysCxRefEntry

atmGenSysCxRefEntry 1.3.6.1.4.1.164.12.2.2.1.5.1
The entries will be added by the agent upon an entry addition in the referenced tables (TD table, FR Descriptor etc.)
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmGenSysCxRefEntry  

atmGenSysCxRefIndex 1.3.6.1.4.1.164.12.2.2.1.5.1.1
The index specifies an entry in the table of the object.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

atmGenSysCxRefCounter 1.3.6.1.4.1.164.12.2.2.1.5.1.2
The counter counts the number of references that have been made to the object .
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

atmAceStatusChange 1.3.6.1.4.1.164.12.3.0.1
The trap is sent every time there is a change in the state of one of the LEDs.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmTrap 1.3.6.1.4.1.164.12.3.0.2
The trap is sent whenever there is a transition from a no alarm state to a state with at least one active alarm. An active alarm state exists if: 1) The atmInterfaceActiveAlarms vector is different than 0. 2) The atmNteAlarmVpTable contains entries. 3) The atmNteAlarmVcTable contains entries. The trap is also sent when a transition into the no alarm state occurs. The second variable will be atmInterfaceActiveAlarms to indicate the kind of the alarm. The trap is not sent more than once in a 10 second interval.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceModuleChangeTrap 1.3.6.1.4.1.164.12.3.0.3
The trap is sent every time a module is changed (Hot swapping). The second variable will be atmNteCardType to indicate the type of card that was inserted. The value empty(255) indicates that a card was taken out.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceRedundancyTrap 1.3.6.1.4.1.164.12.3.0.4
The trap is sent upon change in link as a result of redundancy. The ifIndex parameter indicates the current active link.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceSystemTrap 1.3.6.1.4.1.164.6.1.12.0.6
This trap alerts of major problems in the device.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmForwardingTrap 1.3.6.1.4.1.164.6.1.12.0.7
This trap is sent upon starting or stopping Alarm Forwarding Mechanism.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmLOS 1.3.6.1.4.1.164.6.1.12.0.16
This trap indicates Loss Of Signal.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmLOF 1.3.6.1.4.1.164.6.1.12.0.17
This trap indicates Loss Of Frame.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmLCD 1.3.6.1.4.1.164.6.1.12.0.18
This trap indicates Loss of Cell Delineation.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmSLM 1.3.6.1.4.1.164.6.1.12.0.19
This trap indicates Signal Line Mismatch.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmLOP 1.3.6.1.4.1.164.6.1.12.0.20
This trap indicates Loss of Pointer.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmLineAIS 1.3.6.1.4.1.164.6.1.12.0.21
This trap indicates Line AIS.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmPathAIS 1.3.6.1.4.1.164.6.1.12.0.22
This trap indicates Path AIS.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmLineRDI 1.3.6.1.4.1.164.6.1.12.0.23
This trap indicates Line RDI.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmPathRDI 1.3.6.1.4.1.164.6.1.12.0.24
This trap indicates Path RDIand Path RAI(Yellow) for DS1 interfaces.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmSectionBIP 1.3.6.1.4.1.164.6.1.12.0.25
This trap indicates Section Bit Interleave Parity.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmLineBIP 1.3.6.1.4.1.164.6.1.12.0.26
This trap indicates Line Bit Interleave Parity.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmPathBIP 1.3.6.1.4.1.164.6.1.12.0.27
This trap indicates Path Bit Interleave Parity.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmLineFEBE 1.3.6.1.4.1.164.6.1.12.0.28
This trap indicates Line Far End Block Error.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmPathFEBE 1.3.6.1.4.1.164.6.1.12.0.29
This trap indicates Path Far End Block Error.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmPlcpLOF 1.3.6.1.4.1.164.6.1.12.0.30
This trap indicates T3 PLCP Loss Of Frame.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmPlcpYELLOW 1.3.6.1.4.1.164.6.1.12.0.31
This trap indicates T3 Plcp Yellow.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmPlcpBIP 1.3.6.1.4.1.164.6.1.12.0.32
This trap indicates T3 Plcp Bit Interleave Parity.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmPlcpFEBE 1.3.6.1.4.1.164.6.1.12.0.33
This trap indicates T3 Plcp Far End Block Error.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmPlcpP1P2 1.3.6.1.4.1.164.6.1.12.0.34
This trap indicates T3 Plcp Parity errors in P1/P2 bytes.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmUAS 1.3.6.1.4.1.164.6.1.12.0.35
This trap is sent upon UAS start or end per port.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmCluster 1.3.6.1.4.1.164.6.1.12.0.36
This trap is sent upon atmNteAlarmType start or end, for a cluster of VPs/VCs (according to atmNteLevel) with the same alarm on the same physical port. This trap replaces sending the same alarm for a big quantity (the quantity described in the product specification document) of VPs/VCs in order to prevent flooding the NMS and the network with traps.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceHwFailure 1.3.6.1.4.1.164.6.1.12.0.37
This trap is sent upon HW failure per port.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceUnavailableBwTrap 1.3.6.1.4.1.164.6.1.12.0.38
This trap is sent when Bandwidth allocation is > max possible value for the installed card. For ACE2002 this trap will be sent for the following cases: Card insertion - if the total Input and/or Output Bandwidth is over allocated, then the specific card rate will be set to 0 and this trap will be sent with the Input/Output rates values. Upgrade from former version - when an over allocated Bandwidth is detected, this trap will be sent with atmConfIfInputRate=atmConfIfOutputRate=0xFFFFFFFF.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmVpContinuityLoss 1.3.6.1.4.1.164.6.1.12.0.40
This trap indicates Loss of Continuity Check on a VP Connection.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmVpAISReception 1.3.6.1.4.1.164.6.1.12.0.41
This trap indicates AIS Reception on a VP Connection.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmVpRDIReception 1.3.6.1.4.1.164.6.1.12.0.42
This trap indicates RDI Reception on a VP Connection.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmVpErroredCells 1.3.6.1.4.1.164.6.1.12.0.43
This trap indicates Errored Cells on a VP Connection reported by PM.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmVpLostCells 1.3.6.1.4.1.164.6.1.12.0.44
This trap indicates Lost Cells on a VP Connection reported by PM.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmVpMisinsertedCells 1.3.6.1.4.1.164.6.1.12.0.45
This trap indicates Misinserted Cells on a VP Connection reported by PM.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmVpUAS 1.3.6.1.4.1.164.6.1.12.0.46
This trap is sent upon UAS start or end per VP.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmVpLoopback 1.3.6.1.4.1.164.6.1.12.0.47
This trap is sent upon OAM LoopBack fail status per VP.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmVpGCRAViolation 1.3.6.1.4.1.164.6.1.12.0.48
This trap indicates GCRA violation on a VP Connection reported by UPC device.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmVcContinuityLoss 1.3.6.1.4.1.164.6.1.12.0.56
This trap indicates Loss of Continuity Check on a VC Connection.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmVcAISReception 1.3.6.1.4.1.164.6.1.12.0.57
This trap indicates AIS Reception on a VC.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmVcRDIReception 1.3.6.1.4.1.164.6.1.12.0.58
This trap indicates RDI Reception on a VC Connection.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmVcErroredCells 1.3.6.1.4.1.164.6.1.12.0.59
This trap indicates Errored Cells on a VC Connection reported by PM.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmVcLostCells 1.3.6.1.4.1.164.6.1.12.0.60
This trap indicates Lost Cells on a VC Connection reported by PM.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmVcMisinsertedCells 1.3.6.1.4.1.164.6.1.12.0.61
This trap indicates Misinserted Cells on a VC Connection reported by PM.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmVcUnexpectedCell 1.3.6.1.4.1.164.6.1.12.0.62
This trap indicates an unexpected cell from user or network port.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmVcUAS 1.3.6.1.4.1.164.6.1.12.0.63
This trap is sent upon UAS start or end per VC.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmVcLoopback 1.3.6.1.4.1.164.6.1.12.0.64
This trap is sent upon OAM LoopBack fail status per VC.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmAceAlarmVcGCRAViolation 1.3.6.1.4.1.164.6.1.12.0.65
This trap indicates GCRA violation on a VC Connection reported by UPC device.
Status: current Access: read-only
NOTIFICATION-TYPE    

atmCESAAL1StatsTable 1.3.6.1.4.1.164.12.2.1.2.2.5
This table shows statistics of the structured Circuit-Emulation connections.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmCESAAL1StatsEntry

atmCESAAL1StatsEntry 1.3.6.1.4.1.164.12.2.1.2.2.5.1
defines an entry in the atmCESAAL1StatsTable
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmCESAAL1StatsEntry  

atmCESAAL1SeqErrors 1.3.6.1.4.1.164.12.2.1.2.2.5.1.1
number of cells discarded due to wrong sequence number
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

atmCESAAL1HdrErrors 1.3.6.1.4.1.164.12.2.1.2.2.5.1.2
number of cells discarded due to bad AAL1 header error. this include correctable and uncorrectable CRC, plus bad parity.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

atmCESAAL1PointerReframes 1.3.6.1.4.1.164.12.2.1.2.2.5.1.3
number of events in which the AAL1 reassembler found that an SDT pointer isn't where it is expected, and the pointer must be reacquired.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

atmCESAAL1BufUnderflows 1.3.6.1.4.1.164.12.2.1.2.2.5.1.4
number of buffer underflows events.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

atmCESAAL1BufOverflows 1.3.6.1.4.1.164.12.2.1.2.2.5.1.5
number of buffer overflows events.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

atmNteConfVcTable 1.3.6.1.4.1.164.12.3.2.1.4
The ATM VC configuration table. The table is an extension to the atmVclTable of RFC-2515.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AtmNteConfVcEntry

atmNteConfVcEntry 1.3.6.1.4.1.164.12.3.2.1.4.1
An entry in the ATM VC configuration table. ifIndex of the ATM layer.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmNteConfVcEntry  

atmConfVcPolicing 1.3.6.1.4.1.164.12.3.2.1.4.1.1
Policing method desired for this VCL.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), police(2), monitor(3), shaping(4), policingAndShaping(5), notApplicable(255)  

atmConfVcCCAdminStatus 1.3.6.1.4.1.164.12.3.2.1.4.1.2
up(2) - Activate Continuity Check (CC). down(3) - Deactivate CC. source(4) - Activate OAM CC(Continuity Check) of local agent ( start sending Oam cells to the remote side ). sink(5) - Activate CC of remote agent ( start receiving Oam cells from remote side). listenToActivationCells (6) - Passive listener till gets an activation request originateActivationCells(7) - Sands Activation cell according to atmConfVcCCDirection.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER up(2), down(3), source(4), sink(5), listenToActivationCells(6), originateActivationCells(7)  

atmConfVcLoopbackAdminStatus 1.3.6.1.4.1.164.12.3.2.1.4.1.3
up(2) - Start loopback OAM cells. down(3) - Stop sending loopback OAM cells. For ace2002: up(2) - Transmitting LB cells with llid all ones (i.e. FFFF..FF) down(3) - Not transmitting LB cells. llid(4) - Transmitting LB cells with llid indicated in the address field. segment(5) - Transmitting Segment LB cells with llid all ones. endToEnd(6) - Transmitting End to End LB cells with llid all ones. segmentLlid(7) - Transmitting Segment LB cells with llid indicated in the address field. endToEndLlid(8) - Transmitting LB cells with llid indicated in the address field. This parameter value might be in conflict with atmConfVcOamSupport value, since this parameter is for LB, while atmConfVcOamSupport is for any other OAM cells.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER up(2), down(3), llid(4), segment(5), endToEnd(6), segmentLlid(7), endToEndLlid(8)  

atmConfVcLoopbackSinkAddress 1.3.6.1.4.1.164.12.3.2.1.4.1.4
Destination address. For ace101: 2 bytes are used. For ace2002: 16 bytes are used.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(2..20)  

atmConfVcCongestionControl 1.3.6.1.4.1.164.12.3.2.1.4.1.5
Each bit indicates a selection of one option as the following description. All combinations are possible and legal. The codes are: 1 - EPD 2 - CLP 4 - EFCI. For ace2002: 1 - Packet Discard.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

atmConfVcCCDirection 1.3.6.1.4.1.164.12.3.2.1.4.1.6
both(2) - Agent sends OAM CC cells and checks received OAM CC cells. none(3) - Agent does not send and does not check received OAM CC cells. source(4)- Agent sends OAM CC cells. sink(5) - Agent checks received OAM CC cells.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER both(2), none(3), source(4), sink(5)  

atmConfVcCreationTime 1.3.6.1.4.1.164.12.3.2.1.4.1.7
A date-time in which the VC was created.
Status: current Access: read-only
OBJECT-TYPE    
  DateAndTime  

atmConfVcOamSupport 1.3.6.1.4.1.164.12.3.2.1.4.1.8
OAM support mode, which determines the device location in a segment wise. endToEndAndSegment - In this mode the OAM cells are generated before the ABM (ATM Buffer Manager), so that the PCR and CDVT will not be affected.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER intermediate(1), segmentTermination(2), endToEndTermination(3), endToEndAndSegment(4)  

atmConfVcCCActivationCtrl 1.3.6.1.4.1.164.12.3.2.1.4.1.9
manual(1) - CC Activation process is disable activator(2) - ACE-101 initiate CC Activation process listener(3) - ACE-101 wait to CC Activation request from remote side.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER manual(1), activator(2), listener(3)  

atmConfVcCCOperStatus 1.3.6.1.4.1.164.12.3.2.1.4.1.10
initial (1) - The CC activation process is not started. up (2) - Continuity Check (CC) activated. down (3) - CC deactivated. source (4) - OAM CC(Continuity Check) of local agent activated. sink (5) - OAM CC of remote agent activated. both (8) - OAM CC of local and remote agents activation. timeout (9) - Timeout occured on receiving answer from the remote agent. denied (10) - CC activation process rejected by remote agent. conflict (11) - local and remote sides requested activation simultaneously. manual (12) - OAM CC of local agent activated manually.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER initial(1), up(2), down(3), source(4), sink(5), both(8), timeout(9), denied(10), conflict(11), manual(12)  

atmConfVcLoopbackTraffic 1.3.6.1.4.1.164.12.3.2.1.4.1.11
This parameter has both command and status meanings: off(2) - Set to 'Off' will Stop traffic loop. Getting this value means that the loop is not running. on (3) - Set to 'On' will start traffic loop. Getting this value means that the loop is currently running.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(2), on(3)  

atmConfVcLoopbackFailureInd 1.3.6.1.4.1.164.12.3.2.1.4.1.12
This object allows user to define the Indication that will be created upon a LB cell failure. disabled(2) - no indication will be created. segmentAis(3) - will cause Tx of a segment AIS. segmentRdi(4) - will cause Tx of a segment RDI. segmentAisAndRdi(5) - will cause Tx of a segment AIS & RDI. endToEndAis(6) - will cause Tx of an End to End AIS. endToEndRdi(7) - will cause Tx of an End to End RDI. endToEndAisAndRdi(8) - will cause Tx of an End to End AIS & RDI. Default: disabled(2).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(2), segmentAis(3), segmentRdi(4), segmentAisAndRdi(5), endToEndAis(6), endToEndRdi(7), endToEndAisAndRdi(8)  

atmConfVcLoopbackFailureThreshold 1.3.6.1.4.1.164.12.3.2.1.4.1.13
The number of the LB failures before starting transmission of the Indication defined by atmConfVcLoopbackFailureInd. Range: 1..16. Default: 1.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

atmConfVcOamDirection 1.3.6.1.4.1.164.12.3.2.1.4.1.14
The direction of OAM cell insertion. downStream(2) - The OAM cell will be inserted in downStream. upStream(3) - The OAM cell will be inserted in upStream.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), downStream(2), upStream(3)  

atmConfVcName 1.3.6.1.4.1.164.12.3.2.1.4.1.15
VC Name.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

atmConfVcConnected 1.3.6.1.4.1.164.12.3.2.1.4.1.16
This object indicates whether this VC is connected and if connected, what is it connected to.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notConnected(1), mng(2), bridgePort(3), ds0Bundle(4)  

atmConfVcOamDescrIndex 1.3.6.1.4.1.164.12.3.2.1.4.1.17
This parameter indicates the VCL's OAM Descriptor index, according to the OAM Descriptor Configuration Table.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32