APethPsePortEntry  
SEQUENCE    
  aPethPsePortGroupIndex INTEGER
  aPethPsePortIndex INTEGER
  aPethPsePortAdminEnable INTEGER
  aPethPsePortPowerPairsControlAbility TruthValue
  aPethPsePortPowerPairs INTEGER
  aPethPsePortPowerDetectionControl INTEGER
  aPethPsePortDetectionStatus INTEGER
  aPethPsePortPowerPriority INTEGER
  aPethPsePortPowerMaintenanceStatus INTEGER
  aPethPsePortMPSAbsentCounter Counter32
  aPethPsePortOverCurrentCounter Counter32
  aPethPsePortType INTEGER
  aPethPsePortPowerClassifications INTEGER

APethPdPortEntry  
SEQUENCE    
  aPethPdPortIndex INTEGER
  aPethPdPortAdminEnable INTEGER

APethMainPseEntry  
SEQUENCE    
  aPethMainPseGroupIndex INTEGER
  aPethMainPsePower Integer32
  aPethMainPseOperStatus INTEGER
  aPethMainPseConsumptionPower Gauge32
  aPethMainPseBackupPresent INTEGER
  aPethMainPseBackupActivated TruthValue
  aPethMainPseUsageThreshold INTEGER
  aPethMainPseMaximumDcPower INTEGER

APethNotificationControlEntry  
SEQUENCE    
  aPethNotificationControlGroupIndex INTEGER
  aPethNotificationControlEnable INTEGER

Defined Values

aPowerEthernetMIB 1.3.6.1.2.1.10.7.20
The MIB module for for managing Powered Devices (PD) or Power Source Equipment (PSE) working according to the IEEE 802.af Powered Ethernet (DTE Power via MDI) standard. The following terms are used throughout this MIB module. For complete formal definitions, the IEEE 802.3 standards should be consulted wherever possible: Group - A recommended, but optional, entity defined by the IEEE 802.3 management standard, in order to support a modular numbering scheme. The classical example allows an implementor to represent field-replaceable units as groups of ports, with the port numbering matching the modular hardware implementation. Port - This entity identifies the port within the group for which this entry contains information. The numbering scheme for ports is implementation specific.
MODULE-IDENTITY    

aPethObjects 1.3.6.1.2.1.10.7.20.1
OBJECT IDENTIFIER    

aPethNotifications 1.3.6.1.2.1.10.7.20.2
OBJECT IDENTIFIER    

aPethConformance 1.3.6.1.2.1.10.7.20.3
OBJECT IDENTIFIER    

aPethPsePortTable 1.3.6.1.2.1.10.7.20.1.1
A table of objects that display and control the power characteristics power Ethernet ports on a Power Source Entity (PSE) device. This group will be implemented in managed power Ethernet switches and mid-span devices.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    APethPsePortEntry

aPethPsePortEntry 1.3.6.1.2.1.10.7.20.1.1.1
A set of objects that display and control the power characteristics of a power Ethernet PSE port.
Status: current Access: not-accessible
OBJECT-TYPE    
  APethPsePortEntry  

aPethPsePortGroupIndex 1.3.6.1.2.1.10.7.20.1.1.1.1
This variable uniquely identifies the group containing the port to which a power Ethernet PSE is connected. Group means box in the stack, module in a rack and the value 1 MUST be used for non-modular devices . aPethPseMidSpanGroupCapacity is the number of Mid-Span PSE groups that can be contained within the Mid-Span PSE.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..2147483647  

aPethPsePortIndex 1.3.6.1.2.1.10.7.20.1.1.1.2
This variable uniquely identifies the power Ethernet PSE port within group aPethPseGroupIndex to which the power Ethernet PSE entry is connected.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..2147483647  

aPethPsePortAdminEnable 1.3.6.1.2.1.10.7.20.1.1.1.3
Enables power supply on this port. Setting this object at a value enable(1) enables power and detection mechanism for this port. Setting this object at a value disable(2) disables power for this port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

aPethPsePortPowerPairsControlAbility 1.3.6.1.2.1.10.7.20.1.1.1.4
Describes the capability of controlling the power pairs functionality to switch pins for sourcing power. The value true indicate that the device has the capability to control the power pairs
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

aPethPsePortPowerPairs 1.3.6.1.2.1.10.7.20.1.1.1.5
Describes or controls the pairs in use. If the value of aPethPsePortPowerPairsControl is true, this object is writable. A value of signal(1) menas that the signal pairs only are in use. A value of spare(2) means that the spare pairs only are in use.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER signal(1), spare(2)  

aPethPsePortPowerDetectionControl 1.3.6.1.2.1.10.7.20.1.1.1.6
Controls the power detection mechanism of the port. Setting the value auto(1) enables the power detection mechanism of the port. Setting the value test(2) puts the port in a testmode: force continuous discovery without applying power regardless of whether PD detected.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER auto(1), test(2)  

aPethPsePortDetectionStatus 1.3.6.1.2.1.10.7.20.1.1.1.7
Describes the operational status of the port PD detection. A value of disabled(1)- indicates that the PSE State diagram is in the state IDLE A value of searching(2)- indicates that the PSE State diagram is in the state DETECTION, CLASSIFICATION, SIGNATURE_INVALID or BACKOFF. A value of deliveringPower(4) - indicates that the PSE State diagram is in the state POWER_UP, POWER_ON or POWER_OFF. A value of fault(5) - indicates that the PSE State diagram is in the state TEST_ERROR or the state IDLE due to the variable error condition. Faults detected are vendor specific. A value of test(7) - indicates that the PSE State diagram is in the state TEST_MODE. A value of denyLowPriority(8) indicates that the port was disabled by the power management system, in order to keep active higher priority ports.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER disabled(1), searching(2), deliveringPower(4), fault(5), test(7), denyLowPriority(8)  

aPethPsePortPowerPriority 1.3.6.1.2.1.10.7.20.1.1.1.8
This object controls the priority of the port from the point of view of a power management algorithm. The priority that is set by this variable could be used by a control mechanism that prevents over current situations by disconnecting first ports with lower power priority. Ports that connect devices critical to the operation of the network - like the E911 telephones ports - should be set to higher priority.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER critical(1), high(2), low(3)  

aPethPsePortPowerMaintenanceStatus 1.3.6.1.2.1.10.7.20.1.1.1.10
The value ok(1) indicates the Power Maintenance Signature is present and the overcurrent condition has not been detected. The value overCurrent (2) indicates an overcurrent condition has been detected. The value mPSAbsent(3) indicates that the Power Maintenance Signature is absent.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), underCurrent(2), mPSAbsent(3)  

aPethPsePortMPSAbsentCounter 1.3.6.1.2.1.10.7.20.1.1.1.11
Counts the number of times that the aPethPsePortPowerMaintenanceStatus attribute changes from any value to the value mPSAbsent(3).
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

aPethPsePortOverCurrentCounter 1.3.6.1.2.1.10.7.20.1.1.1.12
Counts the number of times that the aPSEPowerCurrentStatus attribute changes from any value to the value overCurrent(2).
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

aPethPsePortType 1.3.6.1.2.1.10.7.20.1.1.1.13
A manager will set the value of this variable to a value that indicates the type of the device that is connected to theport. This value can be the result of the mapping the address of the station connected to the port and of the value of the aPethPdPortType of the respective PD port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER other(1), telephone(2), webcam(3), wireless(4)  

aPethPsePortPowerClassifications 1.3.6.1.2.1.10.7.20.1.1.1.14
Classification is a way to tag different terminals on the Power over LAN network according to their power consumption. Devices such as IP telephones, WLAN access points and others, will be classified according to their power requirements. The value is only valid while a valid PD is being detected as indicated by the attribute aPethPsePortDetectionStatus reporting the value or deliveringPower(4).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER class0(1), class1(2), class2(3), class3(4), class4(5)  

aPethPdPortTable 1.3.6.1.2.1.10.7.20.1.2
A table of objects that display and control the power characteristics power Ethernet ports on a Powered Device(PD) device. This group will be implemented in managed powered and mid-span devices.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    APethPdPortEntry

aPethPdPortEntry 1.3.6.1.2.1.10.7.20.1.2.1
A set of objects that display and control the power characteristics of a Powered Device port.
Status: current Access: not-accessible
OBJECT-TYPE    
  APethPdPortEntry  

aPethPdPortIndex 1.3.6.1.2.1.10.7.20.1.2.1.1
An index value that uniquely identifies an interface to a PD device. The interface identified by a particular value of this index is the same interface as identified by the same value of ifIndex. The mapping between the ifIndex values and the numbering of the port on the device is an implementation issue.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..65535  

aPethPdPortAdminEnable 1.3.6.1.2.1.10.7.20.1.2.1.2
This value identifies the operational state of the PD functions. An interface which can provide the PD functions will be enabled to do so when this attribute has the value enable. When this attribute has the value disable the interface will act as it would if it had no PD function.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

aPethMainPseObjects 1.3.6.1.2.1.10.7.20.1.3
OBJECT IDENTIFIER    

aPethMainPseTable 1.3.6.1.2.1.10.7.20.1.3.1
A table of objects that display and control the Main power on a PSE device. Example - an Ethernet switch midspan device can control an Ethnternet port and the Main Power supply unit's.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    APethMainPseEntry

aPethMainPseEntry 1.3.6.1.2.1.10.7.20.1.3.1.1
A set of objects that display and control the Main power of a PSE.
Status: current Access: not-accessible
OBJECT-TYPE    
  APethMainPseEntry  

aPethMainPseGroupIndex 1.3.6.1.2.1.10.7.20.1.3.1.1.1
This variable uniquely identifies the group to which power Ethernet PSE is connected.Group means (box in the stack, module in a rack) and the value 1 MUST be used for non-modular devices
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 0..65535  

aPethMainPsePower 1.3.6.1.2.1.10.7.20.1.3.1.1.2
The nominal power of the PSE expressed in Watts.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..65535  

aPethMainPseOperStatus 1.3.6.1.2.1.10.7.20.1.3.1.1.3
The operational status of the main PSE.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2), faulty(3)  

aPethMainPseConsumptionPower 1.3.6.1.2.1.10.7.20.1.3.1.1.4
Measured usage power expressed in Watts.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

aPethMainPseBackupPresent 1.3.6.1.2.1.10.7.20.1.3.1.1.5
reflects the presence of a backup PSE .
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER present(1), notPresent(2), faulty(3)  

aPethMainPseBackupActivated 1.3.6.1.2.1.10.7.20.1.3.1.1.6
- reflects the activation status of the backup PSE . The value true Backup is activated.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

aPethMainPseUsageThreshold 1.3.6.1.2.1.10.7.20.1.3.1.1.7
The usage threshold expressed in percents for comparing the measured power and initiating an alarm if the threshold is exceeded.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..99  

aPethMainPseMaximumDcPower 1.3.6.1.2.1.10.7.20.1.3.1.1.8
Describes the maximum available power in Watt to be supplied by the DC backup source to this device.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

aPethNotificationControl 1.3.6.1.2.1.10.7.20.1.4
OBJECT IDENTIFIER    

aPethNotificationControlTable 1.3.6.1.2.1.10.7.20.1.4.1
A table of objects that display and control the Notification on a PSE device.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    APethNotificationControlEntry

aPethNotificationControlEntry 1.3.6.1.2.1.10.7.20.1.4.1.1
A set of objects that control the Notification events.
Status: current Access: not-accessible
OBJECT-TYPE    
  APethNotificationControlEntry  

aPethNotificationControlGroupIndex 1.3.6.1.2.1.10.7.20.1.4.1.1.1
This variable uniquely identifies the group. Group means box in the stack, module in a rack and it is RECOMENDED that the value 1 be used for non-modular devices
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..65535  

aPethNotificationControlEnable 1.3.6.1.2.1.10.7.20.1.4.1.1.2
Enable Notification from Agent
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

aPethPsePortOnOffNotification 1.3.6.1.2.1.10.7.20.2.1
This Notification indicates if Pse Port is delivering or not power to the PD. This Notification SHOULD be sent on every status change except in the searching mode.
Status: current Access: read-write
NOTIFICATION-TYPE    

aPethPsePortPowerMaintenanceStatusNotification 1.3.6.1.2.1.10.7.20.2.2
This Notification indicates a Port Change Status and it SHOULD be sent on every status change.
Status: current Access: read-write
NOTIFICATION-TYPE    

aPethMainPseBackUpActivatedNotification 1.3.6.1.2.1.10.7.20.2.3
This Notification indicate BackUp is Activated or BackUp is released.
Status: current Access: read-write
NOTIFICATION-TYPE    

aPethMainPowerUsageOnNotification 1.3.6.1.2.1.10.7.20.2.4
This Notification indicate PSE Threshold usage indication is on, the usage power is above the threshold.
Status: current Access: read-write
NOTIFICATION-TYPE    

aPethMainPowerUsageOffNotification 1.3.6.1.2.1.10.7.20.2.5
This Notification indicate PSE Threshold usage indication off, the usage power is below the threshold.
Status: current Access: read-write
NOTIFICATION-TYPE    

aPethCompliances 1.3.6.1.2.1.10.7.20.3.1
OBJECT IDENTIFIER    

aPethGroups 1.3.6.1.2.1.10.7.20.3.2
OBJECT IDENTIFIER    

aPethCompliance 1.3.6.1.2.1.10.7.20.3.1.1
Describes the requirements for conformance to the Power Ethernet MIB.
Status: current Access: read-write
MODULE-COMPLIANCE    

aPethPseCompliance 1.3.6.1.2.1.10.7.20.3.1.2
Describes the requirements for conformance to the PSE and MID- Span.
Status: current Access: read-write
MODULE-COMPLIANCE    

aPethPdCompliance 1.3.6.1.2.1.10.7.20.3.1.3
Describes the requirements for conformance to the PD.
Status: current Access: read-write
MODULE-COMPLIANCE    

aPethPsePortGroup 1.3.6.1.2.1.10.7.20.3.2.1
PSE Port Objects.
Status: current Access: read-write
OBJECT-GROUP    

aPethPdPortGroup 1.3.6.1.2.1.10.7.20.3.2.2
PD Port Objects.
Status: current Access: read-write
OBJECT-GROUP    

aPethMainPseGroup 1.3.6.1.2.1.10.7.20.3.2.3
Main PSE Objects.
Status: current Access: read-write
OBJECT-GROUP    

aPethNotificationControlGroup 1.3.6.1.2.1.10.7.20.3.2.4
Notification Control Objects.
Status: current Access: read-write
OBJECT-GROUP    

aPethPsePortNotificationGroup 1.3.6.1.2.1.10.7.20.3.1.4
Pse Notification indications
Status: current Access: read-write
NOTIFICATION-GROUP    

aPethMainPowerNotificationGroup 1.3.6.1.2.1.10.7.20.3.1.5
Pse Notification indications
Status: current Access: read-write
NOTIFICATION-GROUP