PDN-LINK-FAULT-MGMT-MIB
File:
PDN-LINK-FAULT-MGMT-MIB.mib (10542 bytes)
Imported modules
Imported symbols
Defined Types
PdnLinkFailureConfigEntry |
|
SEQUENCE |
|
|
|
|
pdnLinkFailureLOSPeriodBeforeSwitching |
Integer32 |
|
|
pdnLinkFailureLOFPeriodBeforeSwitching |
Integer32 |
|
|
pdnLinkFailureAISLPeriodBeforeSwitching |
Integer32 |
|
|
pdnLinkFailureSdPeriodBeforeSwitching |
Integer32 |
|
|
pdnLinkFailureSfPeriodBeforeSwitching |
Integer32 |
|
|
pdnLinkFailureSdBerThreshold |
Integer32 |
|
|
pdnLinkFailureSfBerThreshold |
Integer32 |
|
Defined Values
pdnLinkFaultMgmtMIB |
1.3.6.1.4.1.1795.2.24.2.40.1 |
This management information module supports the objects
to be used for fault management configuration on primary
and secondary links. |
MODULE-IDENTITY |
|
|
|
pdnLinkFaultMgmtApsSelection |
1.3.6.1.4.1.1795.2.24.2.40.1.1.1 |
This object is used to enable or disable the
Automatic Protection Switching (Aps) feature
on this device. This object can not be enabled
if the -Switchover due to link failures- is enabled. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
enabled(1), disabled(2) |
|
pdnLinkFaultMgmtSwitchoverSelection |
1.3.6.1.4.1.1795.2.24.2.40.1.1.2 |
This object is used to enable or disable the
Switchover Due to link failures feature on
on this device. This object can not be enabled
if the APS feature is enabled. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
enabled(1), disabled(2) |
|
pdnDualLinkSelection |
1.3.6.1.4.1.1795.2.24.2.40.1.1.4 |
This object is used to enable or disable the
ability to split traffic among dual links. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
enabled(1), disabled(2) |
|
pdnLinkFailureConfigEntry |
1.3.6.1.4.1.1795.2.24.2.40.1.1.3.1 |
Configuration information about a particular
interface being monitored for link failured. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
PdnLinkFailureConfigEntry |
|
|
pdnLinkFailureLOSPeriodBeforeSwitching |
1.3.6.1.4.1.1795.2.24.2.40.1.1.3.1.1 |
This object allows users to configure the amount of
time a LOS condition shall exist on this uplink before
initiating a switchover.
Switchover due to LOS condition on this uplink will
not be valid if any of the APS (Automatic Protection
Switching) is enabled. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..300 |
|
pdnLinkFailureLOFPeriodBeforeSwitching |
1.3.6.1.4.1.1795.2.24.2.40.1.1.3.1.2 |
This object allows users to configure the amount of
time a LOF condition shall exist on this uplink before
initiating a switchover.
Switchover due to LOF condition on this uplink will
not be valid if any of the APS (Automatic Protection
Switching) is enabled. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..300 |
|
pdnLinkFailureAISLPeriodBeforeSwitching |
1.3.6.1.4.1.1795.2.24.2.40.1.1.3.1.3 |
This object allows users to configure the amount of
time a AIS-L condition shall exist on this uplink before
initiating a switchover.
Switchover due to AIS-L condition on this uplink will
not be valid if any of the APS (Automatic Protection
Switching) is enabled. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..300 |
|
pdnLinkFailureSdPeriodBeforeSwitching |
1.3.6.1.4.1.1795.2.24.2.40.1.1.3.1.4 |
This object allows users to configure the amount of
time a Signal Degraded (Sd) condition shall exist on
this uplink before initiating a switchover.
Switchover due to Sd condition on this uplink will
not be valid if any of the APS (Automatic Protection
Switching) is enabled. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..300 |
|
pdnLinkFailureSfPeriodBeforeSwitching |
1.3.6.1.4.1.1795.2.24.2.40.1.1.3.1.5 |
This object allows users to configure the amount of
time a Signal Failure Bit (Sf) condition shall exist on
this uplink before initiating a switchover.
Switchover due to Sf condition on this uplink will
not be valid if any of the APS (Automatic Protection
Switching) is enabled. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..300 |
|
pdnLinkFailureSdBerThreshold |
1.3.6.1.4.1.1795.2.24.2.40.1.1.3.1.6 |
This object allows users to configure the threshold
for the Signal Degrade Bit Error Rate (Sd).
The negated value of this number is used as the exponent
of 10 for computing the threshold value for the Bit Error
Rate (BER). For example, a value of 5 indicates a BER
threshold of 10^-5. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
5..9 |
|
pdnLinkFailureSfBerThreshold |
1.3.6.1.4.1.1795.2.24.2.40.1.1.3.1.7 |
This object allows users to configure the threshold
for the Signal Failure Bit Error Rate (Sf).
The negated value of this number is used as the exponent
of 10 for computing the threshold value for the Bit Error
Rate (BER). For example, a value of 5 indicates a BER
threshold of 10^-5. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
3..5 |
|
pdnLinkFaultMgmtCompliance |
1.3.6.1.4.1.1795.2.24.2.40.1.2.1.1 |
The compliance statement for SNMP entities capable
of configuring link fault conditions. |
Status: current |
Access: read-only |
MODULE-COMPLIANCE |
|
|
|
pdnLinkFaultMgmtGeneralGroup |
1.3.6.1.4.1.1795.2.24.2.40.1.2.2.1 |
A collection of configuration objects applicable
to link fault mgmt implementation. |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|
pdnLinkSwitchoverGroup |
1.3.6.1.4.1.1795.2.24.2.40.1.2.2.2 |
A collection of configuration objects applicable to
all redundancy implementations. |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|