PBN-MIB

File: PBN-MIB.mib (220322 bytes)

Imported modules

RFC-1212 RFC-1215 RFC1155-SMI
RFC1213-MIB SNMPv2-SMI

Imported symbols

OBJECT-TYPE TRAP-TYPE TimeTicks
enterprises IpAddress Counter
Opaque DisplayString Integer32

Defined Types

TypePowerSupply  
INTEGER ac220V(1), ac60V(2)    

TypeTamper  
INTEGER open(1), yes(2)    

TypeYesNo  
INTEGER no(1), yes(2)    

TypeOnOff  
INTEGER off(1), on(2)    

TypeAGCStatus  
INTEGER unlock(1), lock(2)    

TypeGainMode  
INTEGER auto(1), manual(2)    

Defined Values

pbn 1.3.6.1.4.1.11606
OBJECT IDENTIFIER    

pbnTrap 1.3.6.1.4.1.11606.0
OBJECT IDENTIFIER    

ocm 1.3.6.1.4.1.11606.1
OBJECT IDENTIFIER    

pbnDevice 1.3.6.1.4.1.11606.1.1
PBN Networks Management Devices
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1 | 2 | 30  

deviceAddress 1.3.6.1.4.1.11606.1.2
PBN Networks Management Device Address
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

ocmSlot 1.3.6.1.4.1.11606.1.3
The OCM slot of the PBN device
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..8  

ocmPage 1.3.6.1.4.1.11606.1.4
The Device Page
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..7  

ocmParam 1.3.6.1.4.1.11606.1.5
The Device Parameter
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..31  

ocmParamStatus 1.3.6.1.4.1.11606.1.6
The parameter status
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..3  

ocmParamString 1.3.6.1.4.1.11606.1.7
The parameter string
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

ocmWriteParameterValue 1.3.6.1.4.1.11606.1.8
The Write Parameter Value ID
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ocmToggleParameterValue 1.3.6.1.4.1.11606.1.9
The Toggle Parameter Value ID
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ocmReadParameterValue 1.3.6.1.4.1.11606.1.10
The Toggle Parameter Value ID
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpon100 1.3.6.1.4.1.11606.2
OBJECT IDENTIFIER    

cpon100Trap 1.3.6.1.4.1.11606.2.0
OBJECT IDENTIFIER    

catvCtrl 1.3.6.1.4.1.11606.2.1
CATV Service Control
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

masterAlarmStatus 1.3.6.1.4.1.11606.2.2
Master Alarm Status
Status: obsolete Access: read-only
OBJECT-TYPE    
  INTEGER 0..1  

contactInput 1.3.6.1.4.1.11606.2.3
Tamper Status
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1  

catvStatus 1.3.6.1.4.1.11606.2.4
CATV Service Status
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..3  

sensingInput 1.3.6.1.4.1.11606.2.5
Sensing Input
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1  

globalPktSize 1.3.6.1.4.1.11606.2.6
Packet Size
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2  

globalMulticastStormProtection 1.3.6.1.4.1.11606.2.7
Multicast Storm Protection
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

globalFlowCtrl 1.3.6.1.4.1.11606.2.8
Flow Control
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..3  

globalBackPressureMode 1.3.6.1.4.1.11606.2.9
Back Pressure Mode
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

globalPriorityBufferReserve 1.3.6.1.4.1.11606.2.10
Priority Buffer Reserve
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

globalPriorityScheme 1.3.6.1.4.1.11606.2.11
Priority Scheme Select
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..3  

global802dot1PBasedPriority 1.3.6.1.4.1.11606.2.12
802.1p Based priority
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..7  

global802dot1qVLANEnable 1.3.6.1.4.1.11606.2.13
802.1q VLAN enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

globalNullVIDReplacement 1.3.6.1.4.1.11606.2.14
Null VID Replacement
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

sourceMACPauseCtrl 1.3.6.1.4.1.11606.2.15
Source Address MAC Pause
Status: mandatory Access: read-write
OBJECT-TYPE    
  Opaque Size(6)  

globalFastAge 1.3.6.1.4.1.11606.2.16
Fast Age
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

cpon100MACAddr 1.3.6.1.4.1.11606.2.17
CPON-100 SNMP MAC Address
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..5)  

cpon100TrapStatus 1.3.6.1.4.1.11606.2.18
CPON-100 Trap severity
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..2  

cpon100TrapMsg 1.3.6.1.4.1.11606.2.19
CPON-100 Trap Message
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..63)  

vlanTable 1.3.6.1.4.1.11606.2.21
OBJECT IDENTIFIER    

vlanAddr1 1.3.6.1.4.1.11606.2.21.1
CPON-100-100 VLAN1
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..16777215  

vlanAddr2 1.3.6.1.4.1.11606.2.21.2
CPON-100 VLAN2
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..16777215  

vlanAddr3 1.3.6.1.4.1.11606.2.21.3
CPON-100 VLAN3
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..16777215  

staticMACTable 1.3.6.1.4.1.11606.2.22
OBJECT IDENTIFIER    

staticMAC1 1.3.6.1.4.1.11606.2.22.1
Static MAC entry 1
Status: mandatory Access: read-write
OBJECT-TYPE    
  Opaque Size(8)  

staticMAC2 1.3.6.1.4.1.11606.2.22.2
Static MAC entry 2
Status: mandatory Access: read-write
OBJECT-TYPE    
  Opaque Size(8)  

staticMAC3 1.3.6.1.4.1.11606.2.22.3
Static MAC entry 3
Status: mandatory Access: read-write
OBJECT-TYPE    
  Opaque Size(8)  

staticMAC4 1.3.6.1.4.1.11606.2.22.4
Static MAC entry 4
Status: mandatory Access: read-write
OBJECT-TYPE    
  Opaque Size(8)  

staticMAC5 1.3.6.1.4.1.11606.2.22.5
Static MAC entry 5
Status: mandatory Access: read-write
OBJECT-TYPE    
  Opaque Size(8)  

dynamicMACTable 1.3.6.1.4.1.11606.2.23
OBJECT IDENTIFIER    

macEntryCnt 1.3.6.1.4.1.11606.2.23.1
Dynamic MAC Entry Count
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1024  

macEntryID 1.3.6.1.4.1.11606.2.23.2
Dynamic MAC Entry ID
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1024  

macEntry 1.3.6.1.4.1.11606.2.23.3
Dynamic MAC entry data
Status: mandatory Access: read-only
OBJECT-TYPE    
  Opaque Size(8)  

cpon100Port1 1.3.6.1.4.1.11606.2.24
OBJECT IDENTIFIER    

port1LinkStatus 1.3.6.1.4.1.11606.2.24.1
Port1 Link Status
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1  

port1MDIXStatus 1.3.6.1.4.1.11606.2.24.2
Port1 MID-X Status
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1  

port1AutoNegotiationStatus 1.3.6.1.4.1.11606.2.24.3
Port1 Auto-Negotiation Status
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1  

port1LinkCapability 1.3.6.1.4.1.11606.2.24.4
Link Capability
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..15  

port1FlowCtrlCapability 1.3.6.1.4.1.11606.2.24.5
Port1 Flow Control Capability
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1  

port1FarEndFaultStatus 1.3.6.1.4.1.11606.2.24.6
Port1 Far End Fault Status
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1  

port1RxLoPriorityByte 1.3.6.1.4.1.11606.2.24.7
Port1 Receive Low Priority Octet Counter
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

port1RxHiPriorityByte 1.3.6.1.4.1.11606.2.24.8
Port1 Receive High Priority Octet Counter
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

port1UndersizePkt 1.3.6.1.4.1.11606.2.24.9
Port1 Undersize Packet Counter
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

port1RxJabbers 1.3.6.1.4.1.11606.2.24.12
Port1 Receive Jabbers Counter
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

port1CRCError 1.3.6.1.4.1.11606.2.24.14
Port1 CRC Error Counter
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

port1RxPausePkts 1.3.6.1.4.1.11606.2.24.17
Port1 Receive Pause Packet Counter
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

port1Broadcast 1.3.6.1.4.1.11606.2.24.18
Port1 Good Broadcast Packet counter
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

port1RxMulticast 1.3.6.1.4.1.11606.2.24.19
Port1 Receive Good Multicast Packet Counter
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

port1RxUnicast 1.3.6.1.4.1.11606.2.24.20
Port1 Receive Unicast Counter
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

port1Rx64Octets 1.3.6.1.4.1.11606.2.24.21
Port1 Receive 64Octets Counter
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

port1Rx65to127Octets 1.3.6.1.4.1.11606.2.24.22
Port1 Receive 65 to 127 Octets Counter
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

port1Rx128to255Octets 1.3.6.1.4.1.11606.2.24.23
Port1 Receive 128 to 255 Octets Counter
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

port1Rx256to511Octets 1.3.6.1.4.1.11606.2.24.24
Port1 Receive 256 to 511 Octets Counter
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

port1Rx512to1023Octets 1.3.6.1.4.1.11606.2.24.25
Port1 Receive 512 to 1023 Octets Counter
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

port1Rx1024to1522Octets 1.3.6.1.4.1.11606.2.24.26
Port1 Receive 1024 to 1522 Octets Counter
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

port1TxLoPriorityByte 1.3.6.1.4.1.11606.2.24.27
Port1 Transmit Low Priority Good Octet Counter
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

port1TxHiPriorityByte 1.3.6.1.4.1.11606.2.24.28
Port1 Transmit High Priority Good Octet Counter
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

port1PausePkts 1.3.6.1.4.1.11606.2.24.30
Port1 Pause Packet Counter
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

port1TxBroadcastPkts 1.3.6.1.4.1.11606.2.24.31
Port1 Transmit Good Broadcast Packet Counter
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

port1TxMulticastPkts 1.3.6.1.4.1.11606.2.24.32
Port1 Transmit Good Multicast Packet Counter
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

port1TxUnicastPkts 1.3.6.1.4.1.11606.2.24.33
Port1 Transmit Good Unicast Packet Counter
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

port1TxTotalCollision 1.3.6.1.4.1.11606.2.24.35
Port1 Transmit Total Collision Packet Counter for half-duplex only
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

port1TxDroppedPkts 1.3.6.1.4.1.11606.2.24.39
Port1 Transmit Drop Packet Counter
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

port1RxDroppedPkts 1.3.6.1.4.1.11606.2.24.40
Port1 Receive Drop Packet Counter
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cpon100Port1Ctrl 1.3.6.1.4.1.11606.2.24.45
OBJECT IDENTIFIER    

port1CtrlDiffServPriority 1.3.6.1.4.1.11606.2.24.45.1
Port1 DiffServe Priority Control
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

port1Ctrl802dot1pPriorityClass 1.3.6.1.4.1.11606.2.24.45.2
Port1 802.1p Priority Class Enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

port1CtrlPortBasedPriority 1.3.6.1.4.1.11606.2.24.45.3
Port1 Port Based Priority
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

port1CtrlPriorityCtrl 1.3.6.1.4.1.11606.2.24.45.4
Port1 Priority Enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

port1CtrlAutoNegotiation 1.3.6.1.4.1.11606.2.24.45.5
Port1 Auto-Negotiation Enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

port1CtrlForceFullDuplex 1.3.6.1.4.1.11606.2.24.45.6
Port1 Force Full-duplex
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

port1CtrlBroadcastStormProtection 1.3.6.1.4.1.11606.2.24.45.7
Port1 Broadcast Storm Protection
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

port1CtrlForceFlowCtrl 1.3.6.1.4.1.11606.2.24.45.8
Port1 Force Flow Control
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

port1CtrlBackPressure 1.3.6.1.4.1.11606.2.24.45.9
Port1 Backpressure Enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

port1CtrlTxEnable 1.3.6.1.4.1.11606.2.24.45.10
Port1 Transmit Enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

port1CtrlRxEnable 1.3.6.1.4.1.11606.2.24.45.11
Port1 Receive Enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

port1CtrlPowerDown 1.3.6.1.4.1.11606.2.24.45.12
Port1 Port Powerdown
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

port1CtrlMACLoopBackTest 1.3.6.1.4.1.11606.2.24.45.13
Port1 MAC Loopback Test
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

port1CtrlPHYLoopbackTest 1.3.6.1.4.1.11606.2.24.45.14
Port1 PHY Loopback Test
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

port1CtrlRemoteLoopbackTest 1.3.6.1.4.1.11606.2.24.45.15
Port1 Remote Loopback Test
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

port1CtrlTagInsertionRemoval 1.3.6.1.4.1.11606.2.24.45.16
Port1 Tag Insertion/Tag Removal
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..3  

port1CtrlPortMembership 1.3.6.1.4.1.11606.2.24.45.17
Port1 Port Membership
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..31  

port1CtrlIngressVLANFiltering 1.3.6.1.4.1.11606.2.24.45.18
Port1 Ingress VLAN Filtering
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

port1CtrlDiscardNon-PVIDPkt 1.3.6.1.4.1.11606.2.24.45.19
Port1 Discard Non-PVID Packet
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

port1CtrlDefaultTag 1.3.6.1.4.1.11606.2.24.45.20
Port1 Default Tag
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65536  

port1CtrlForceSpeed 1.3.6.1.4.1.11606.2.24.45.21
Port1 Force Speed
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

cpon100Port2 1.3.6.1.4.1.11606.2.25
OBJECT IDENTIFIER    

port2LinkStatus 1.3.6.1.4.1.11606.2.25.1
Port2 Link Status
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1  

port2MDIXStatus 1.3.6.1.4.1.11606.2.25.2
Port2 MDI-X Status
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1  

port2AutoNegotiationStatus 1.3.6.1.4.1.11606.2.25.3
Port2 Auto-Negotiation Status
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1  

port2LinkCapability 1.3.6.1.4.1.11606.2.25.4
Port2 Link Capability
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..15  

port2FlowCtrlCapability 1.3.6.1.4.1.11606.2.25.5
Port2 Flow Control Capability
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1  

port2FarEndFaultStatus 1.3.6.1.4.1.11606.2.25.6
Port2 Far End Fault Status
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1  

port2RxLoPriorityByte 1.3.6.1.4.1.11606.2.25.7
Port2 Receive Low Priority Octet Counter
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

port2RxHiPriorityByte 1.3.6.1.4.1.11606.2.25.8
Port2 Receive High Priority Octet Counter
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

port2UndersizePkt 1.3.6.1.4.1.11606.2.25.9
Port2 Undersize Packet Counter
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

port2RxJabbers 1.3.6.1.4.1.11606.2.25.12
Port2 Receive Jabbers Counter
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

port2CRCError 1.3.6.1.4.1.11606.2.25.14
Port2 CRC Error Counter
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

port2RxPausePkts 1.3.6.1.4.1.11606.2.25.17
Port2 Receive Pause Packet Counter
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

port2Broadcast 1.3.6.1.4.1.11606.2.25.18
Port2 Broadcast Good Packet Counter
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

port2RxMulticast 1.3.6.1.4.1.11606.2.25.19
Port2 Receive Multicast Good Packet Counter
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

port2RxUnicast 1.3.6.1.4.1.11606.2.25.20
Port2 Receive Unicast Counter
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

port2Rx64Octets 1.3.6.1.4.1.11606.2.25.21
Port2 Receive 64 Octets Counter
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

port2Rx65to127Octets 1.3.6.1.4.1.11606.2.25.22
Port2 Receive 65 to 127 Octets Counter
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

port2Rx128to255Octets 1.3.6.1.4.1.11606.2.25.23
Port2 Receive 128 to 255 Octets Counter
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

port2Rx256to511Octets 1.3.6.1.4.1.11606.2.25.24
Port2 Receive 256 to 511 Octets Counter
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

port2Rx512to1023Octets 1.3.6.1.4.1.11606.2.25.25
Port2 Receive 512 to 1023 Octets Counter
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

port2Rx1024to1522Octets 1.3.6.1.4.1.11606.2.25.26
Port2 Receive 1024 to 1522 Octets Counter
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

port2TxLoPriorityByte 1.3.6.1.4.1.11606.2.25.27
Port2 Transmit Low Priority Packet Counter
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

port2TxHiPriorityByte 1.3.6.1.4.1.11606.2.25.28
Port2 Transmit High Priority Packet Counter
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

port2PausePkts 1.3.6.1.4.1.11606.2.25.30
Port2 Pause Packet Counter
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

port2TxBroadcastPkts 1.3.6.1.4.1.11606.2.25.31
Port2 Transmit Broadcast Packet Counter
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

port2TxMulticastPkts 1.3.6.1.4.1.11606.2.25.32
Port2 Transmit Multicast Packet Counter
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

port2TxUnicastPkts 1.3.6.1.4.1.11606.2.25.33
Port2 Transmit Unicast Packet Counter
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

port2TxTotalCollision 1.3.6.1.4.1.11606.2.25.35
Port2 Transmit Total Collision Packet Counter
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

port2TxDroppedPkts 1.3.6.1.4.1.11606.2.25.39
Port2 Transmit Dropped Packet Counter
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

port2RxDroppedPkts 1.3.6.1.4.1.11606.2.25.40
Port2 Receive Dropped Packet Counter
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

port2Ctrl 1.3.6.1.4.1.11606.2.25.45
OBJECT IDENTIFIER    

port2CtrlDiffServPriority 1.3.6.1.4.1.11606.2.25.45.1
Port2 DiffServe Priority Control
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

port2Ctrl802dot1pPriorityClass 1.3.6.1.4.1.11606.2.25.45.2
Port2 802.1p Priority Class Enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

port2CtrlPortBasedPriority 1.3.6.1.4.1.11606.2.25.45.3
Port2 802.1p Priority Class Enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

port2CtrlPriorityCtrl 1.3.6.1.4.1.11606.2.25.45.4
Port2 Priority Enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

port2CtrlAutoNegotiation 1.3.6.1.4.1.11606.2.25.45.5
Port2 Auto-Negotiation Enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

port2CtrlForcedFullDuplex 1.3.6.1.4.1.11606.2.25.45.6
Port2 Force Full-duplex
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

port2CtrlBroadcastStormProtection 1.3.6.1.4.1.11606.2.25.45.7
Port2 Broadcast Storm Protection Enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

port2CtrlForceFlowCtrl 1.3.6.1.4.1.11606.2.25.45.8
Port2 Force Flow Control
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

port2CtrlBackPressure 1.3.6.1.4.1.11606.2.25.45.9
Port2 Back Pressure Enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

port2CtrlTxEnable 1.3.6.1.4.1.11606.2.25.45.10
Port2 Transmit Enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

port2CtrlRxEnable 1.3.6.1.4.1.11606.2.25.45.11
Port2 Receive Enable
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

port2CtrlPowerDown 1.3.6.1.4.1.11606.2.25.45.12
Port2 Powerdown
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

port2CtrlMACLoopBackTest 1.3.6.1.4.1.11606.2.25.45.13
Port2 MAC Loopback Test
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

port2CtrlPHYLoopbackTest 1.3.6.1.4.1.11606.2.25.45.14
Port2 PHY Loopback Test
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

port2CtrlRemoteLoopbackTest 1.3.6.1.4.1.11606.2.25.45.15
Port2 Remote Loopback Test
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

port2CtrlTagInsertionRemoval 1.3.6.1.4.1.11606.2.25.45.16
Port2 Tag Insertion/Tag Removal
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..3  

port2CtrlPortMembership 1.3.6.1.4.1.11606.2.25.45.17
Port2 Port Membership
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..31  

port2CtrlIngressVLANFiltering 1.3.6.1.4.1.11606.2.25.45.18
Port2 Ingress VLAN Filtering
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

port2CtrlDiscardNon-PVIDPkt 1.3.6.1.4.1.11606.2.25.45.19
Port2 Discard Non-PVID Packet
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

port2CtrlDefaultTag 1.3.6.1.4.1.11606.2.25.45.20
Port2 Default Tag
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65536  

port2CtrlForceSpeed 1.3.6.1.4.1.11606.2.25.45.21
Port2 Force Speed
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  


priUplinkLinkStatus 1.3.6.1.4.1.11606.2.26.1
Uplink Link Status
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1  

priUplinkPortCtrl 1.3.6.1.4.1.11606.2.26.45
OBJECT IDENTIFIER    

priUplinkLinkRemoteLoopbackTest 1.3.6.1.4.1.11606.2.26.45.15
Primary uplink Link Remote loopback test
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1  

priUplinkTxLoPriorityRateCtrl 1.3.6.1.4.1.11606.2.26.45.22
Primary Uplink Transmit Low Priority Rate Control
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4095  

priUplinkRxLoPriorityRateCtrl 1.3.6.1.4.1.11606.2.26.45.23
Primary Uplink Receive Low Priority Rate Control
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4095  

priUplinkTxDiffPriorityRateCtrl 1.3.6.1.4.1.11606.2.26.45.24
Primary Uplink Transmit Differential Priority Rate Control
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1  

odnrt100 1.3.6.1.4.1.11606.3
OBJECT IDENTIFIER    

oslam8g 1.3.6.1.4.1.11606.4
OBJECT IDENTIFIER    

oslam8g-Global 1.3.6.1.4.1.11606.4.1
OBJECT IDENTIFIER    

oslam8g-globalCtrl 1.3.6.1.4.1.11606.4.1.1
OBJECT IDENTIFIER    

oslam8gSrcMACAddr 1.3.6.1.4.1.11606.4.1.1.1
OSLAM-8G Source MAC address =========================== 48bit Source address MAC address for pause control frame. NOTE: First bit of 2nd octet is as followed: This bit used to have all ports transmit the same or different source addresses in full-duplex Pause frames. 0 - All ports transmit the same Static Address (SA) 1 - Each port uses a different SA where bits 4:47 of the 'sourceMACAddress' are the same, but bits 3:0 are the port number (Port 0 = 0, Port1 = 1, Port 2 = 2, etc.)
Status: mandatory Access: read-write
OBJECT-TYPE    
  Opaque Size(6)  

oslam8gSchedulingMode 1.3.6.1.4.1.11606.4.1.1.2
OSLAM-8G Scheduling Mode ========================= 1 - Use an 8,4,2,1 weighted fair queuing scheme 2 - Us a strict priority scheme
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER useFairQueuingScheme(1), useStrictPriorityScheme(2)  

oslam8gMaxFrameSize 1.3.6.1.4.1.11606.4.1.1.3
Maximum Frame Size allowed. =========================== The Ingress block discards all frames less than 64 bytes in size. It also discards all frames greater than a certain size (regardless of whether or not the frame is iEEE802.3ac tagged) as follows: 1 - Max size is 1522 for IEEE tagged frames, 1518 for untagged frames. 2 - Max size is 1632
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER sizeMax1522Octets(1), sizeMax1632Octets(2)  

oslam8gCoreTag 1.3.6.1.4.1.11606.4.1.1.4
OSLAM-8G Core Tag Type ====================== Core Tag Ether Type. This EtherType is added to frames that egress the switch as Double Tagged frames. It is also the EtherType expected during Ingress to determine if a frame is Tagged or not on ports configured in oslam8gPortEgressMode as follows: For Ingress: =========== oslam8gUseCoreTag= 1, oslam8gDoubleTag = 1, TagType = 0x8100 oslam8gUseCoreTag= 1, oslam8gDoubleTag = 2, TagType = 0x8100 oslam8gUseCoreTag= 2, oslam8gDoubleTag = 1, TagType = oslam8gCoreTagType oslam8gUseCoreTag= 2, oslam8gDoubleTag = 2, 1st TagType = oslam8gCoreTagType then 2nd TagType in the frame = 0x8100 For Egress: =========== Normal Add a Tag (standard IEEE rule) Added Tag Type = 0x8100 Always Add a Tag (Egress DoubleTag) Added Tag Type = oslam8gCoreTagType
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

oslam8gUseDoubleTagData 1.3.6.1.4.1.11606.4.1.1.5
OSLAM-8G Use Double Tag Data ============================ Used to determine if Double Tag data is removed from a Double Tag frame is used or ignored when making switching decisions on the frame. 1 - Ignore removed Tag data 2 - Use removed Tag data This OID have not effect if hte port's oslam8gPortDoubleTag is set to 1
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ignoreRemovedTagData(1), useRemovedTagData(2)  

oslam8g-globalStatus 1.3.6.1.4.1.11606.4.1.2
OBJECT IDENTIFIER    

oslam8gSerialNumber 1.3.6.1.4.1.11606.4.1.2.1
OSLAM-8G Serial Number
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

oslam8gMACAddress 1.3.6.1.4.1.11606.4.1.2.2
OSLAM-8G SNMP MAC Address
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(12)  

oslam8gDiagnosticMsg 1.3.6.1.4.1.11606.4.1.2.3
OSLAM-8G Diagnostic Message
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..63)  

oslam8g-VTU 1.3.6.1.4.1.11606.4.1.3
OBJECT IDENTIFIER    

vtuOperation 1.3.6.1.4.1.11606.4.1.3.1
VLAN Table Unit Table Operation =============================== Support the following VTU operation. 0, 2 - No Operation 1 - Flush All Entries 3 - Load(1) or Purge(2) an Entry 4 - Get Next(3) 5,6 - Reserve 7 - Get/Clear Violation Data NOTE: (1) - An Entry is Loaded when the 'vtuValid' is set to a one. Load is the only 'vtuOperation' that uses the 'vtuDBNum' field and it uses it as data to be loaded along with the desired 'vtuVID'. (2) - An Entry is Purged when the 'vtuValid' is cleared to a zero. (3) - A Get Next operation finds the next higher 'vtuVID' curretnly in the database. The vtuVID value is used as the VID to start from. To find the lowest VID set the vtuVID field to ones. When the operation is done the vtuVID field contains the next higher VID currently active in the database. To find the next VID simply issue the Get Next opcode again. If the vtuVID field is returned set to a one's with the vtuValid cleared to zero, no higher VID's were found. To Search for a particular VID, perform a Get Next operation using a vtuVID field with a value one less than the one being searched for.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER flushAllEntries(1), noOperation(2), loadOrPurgeEntry(3), getNext(4), getClearViolation(7)  

vtuDBNum 1.3.6.1.4.1.11606.4.1.3.2
VTU MAC Address Database Number =============================== On all vtuOperation except for Get Violation Data, this field is used to separate MAC address dtabases by a frame's VID. If multiple address databases are not being used, theses bits must remain zero. If multiple addresss are not being used, theses bits must remain zero. If multiple address databases are being used, these bits are used to get the desired database number that is associated with VID value on Load operations (or used to read the currently assigned vtuDBNum on Get Next operations).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

vtuMemberViolation 1.3.6.1.4.1.11606.4.1.3.3
VTU Member Violation ================== Source Member Violation. On Get/Clear Violation Data vtuOperation, this value is returned set to a two(2) if the Violation being serviced is due to an 802.1Q Member Violation. A member Violation occurs when an 802.1Q enabled ingress port accesses the VTU with a VID that is cotnained in the VTU but whose Mebership list does not include this Ingress port. Only the first vtuFullViolation, vtuMemberViolation, vtuMissViolation is saved per port until cleared.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noViolation(1), violation(2)  

vtuMissViolation 1.3.6.1.4.1.11606.4.1.3.4
VTU Miss Violation ================== On Get/Clear Violation operation this value is set to a two(2) if the Violation being serviced is due to 802.1Q Miss Violation. A Miss Violation occurs when an 802.1Q enabled Ingress port accesses the VTU with a VID that is contained in the VTU. Only the first atuFullViolation, atuMemberViolation, atuMissViolation is saved per port until cleared.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noViolation(1), violation(2)  

vtuValid 1.3.6.1.4.1.11606.4.1.3.5
VTU Entry Valid status. ======================= At the end of Get/Next operations 1 - If VID is all ones, it indicates the end of the VID list was reached with no new valid entries. 2 - Indicates the VID value below is valid. NOTE: On Load or Purge operations, this bit indicates the desired operation of a Load (when set to a one) or a Purge (when cleared to a zero).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER invalidVIDOrEndOflist(1), validVID(2)  

vtuVID 1.3.6.1.4.1.11606.4.1.3.6
VLAN Identifier =============== This VID is used in all the vtuOperation commands (except Get/Clear Violation Data) and it is the VID that is associated with the vtuData or the vtuVID that caused the VTU Violation. Theses indicate the VID number that is associated with the MemberTag in the vtuData, 802.1s PortState, Priority and its override.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4095  

vtuData 1.3.6.1.4.1.11606.4.1.3.7
VLAN table data Entry Format as follow: ====================== BYTE#: 5 4 3 2 1 0 Frame: [0:P10][P9:P8][P7:P6][P5:P4][P3:P2][P1:P0] Px: Port control Size: 4bits total Format: [PortState][PortMemberTag] PortState: The upper two bits of each port's VTU data is called 802.1s PortState. These bits are used to support 802.1s per VLAN spanning tree as follows: 00 - 802.1s Disabled. User non-VLAN Port states (in Port control 'portState') 01 - Blocking/Listening Port State for this port for frames with this VID 10 - Learning Port State for this port for frames with this VID 11 - Forwarding Port State for this port for frames with this VID NOTE: These 802.1s PortState bits take precedence over the port's 'portState' in port control unless the port's 'portState' is Disabled (which prevents all frames from flowing). MemberTag: Size: 2bits The lower two bits of each port's VTU data is called MemberTag. These bits are used to indicate which ports are members of the VLAN and if these VLANs frames should be tagged or untagged, or unmodified when exiting the port as follows: 00 - Port is a member of this VLAN and frames are to egress unmodified. 01 - Port is a member of this VLAN and frames are to egress Untagged. 10 - Port is a member of this VLAN and frames are to egress Tagged. 11 - Port is not a member of this VLAN
Status: mandatory Access: read-write
OBJECT-TYPE    
  Opaque Size(6)  

vtuVIDPRI 1.3.6.1.4.1.11606.4.1.3.8
VID Priority ============ These bits are used to override the priority on any frames associated with this VID value, if the 'vtuVIDPRIOverride' is set to one.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..7  

vtuVIDPRIOverride 1.3.6.1.4.1.11606.4.1.3.9
VID Priority Override ===================== 1 - No priority override. 2 - The vtuVIDPRI are used to override the priority on any frames associated with this VID as long as the port's 'portVTUPriOverride' is set.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noPriorityOverride(1), priorityOverride(2)  

oslam8g-ATU 1.3.6.1.4.1.11606.4.1.4
OBJECT IDENTIFIER    

atuOperation 1.3.6.1.4.1.11606.4.1.4.1
Address Translation Unit (ATU) Opcode: ====================================== 1 - Flush All Entries 2 - Flush all Non-Static Entries 3 - Load or Purge an Entry in a particular atuDBNum Database 4 - Get Next from a particular atuDBNum Database 5 - Flush all Entries in a particular atuDBNum Database 6 - Flush all Non-Static Entries in a particular atuDBNum Database 7 - Get/Clear Violation Data. 8 - No operation
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER flushAllEntries(1), flushAllDynamicEntries(2), loadOrPurgeEntry(3), getNext(4), flushAllStaticIntriesInSelectedDBNum(5), flushAllDynamicEntriesInSelectedDBNum(6), getClearViolation(7), noOperation(8)  

atuDBNum 1.3.6.1.4.1.11606.4.1.4.2
ATU MAC Address Database Number (DBNum) ======================================= If multiple address databases are not being used theses bits must remain zero. If multiple address databases are being used theses are used to set the desired address database number that is being used on the Database supported commands (atuOperation 0x03, 0x04, 0x05 and 0x06). On Get/Clear Violation Data atuOperation these bits return the atuDBNum value associated with the ATU violation that was just serviced.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

atuMemberViolation 1.3.6.1.4.1.11606.4.1.4.3
ATU Member Violation ================== On Get/Clear Violation operation this value is set to a two(2) if the Violation being serviced is due to a Source Address Look-up that resulted in a Hit but where the 'atuState' and 'atuPortVec' bits does not contain the frame's Ingress port bit set to a two(2) (i.e. a station moved occurred). This violation can be masked on a per port basis by setting the port's ignoreWrongData bit. Only the first atuFullViolation, atuMemberViolation, atuMissViolation is saved per port until cleared.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noViolation(1), violation(2)  

atuMissViolation 1.3.6.1.4.1.11606.4.1.4.4
ATU Miss Violation ================== On Get/CLear Violation operation this value is set to a two(2) if the Violation being serviced is due to a Source Address Look-up that resulted in a Miss on ports that are locked (i.e., CPU directed learning is enabled on the port). Only the first atuFullViolation, atuMemberViolation, atuMissViolation is saved per port until cleared.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noViolation(1), violation(2)  

atuFullViolation 1.3.6.1.4.1.11606.4.1.4.5
ATU Full Violation ================== On Get/Clear Violation operation this value is set to a two(2) if the Violation being serviced is due to a Load operation or automatic learn that could not store the desired entry. This only occurs if all available locations for the desired address contain other MAC addresses that are loaded Static. Only the first atuFullViolation, atuMemberViolation, atuMissViolation is saved per port until cleared.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noViolation(1), violation(2)  

atuAgeTime 1.3.6.1.4.1.11606.4.1.4.6
ATU Age Time ============ These bits determine the time that each ATU Entry remains valid in the database, since its last access as a source address, before being purged. The value in this register times 15 is the age time in seconds. For example: The default value of 0x14 is 20 decimal. 20x15 = 300 seconds or 5 minutes. If the atuAgeTime is 0xFF or 3825 seconds or almost 64 minutes. if the atuAgeTime is set to 0 the Aging function is disabled and all learned addresses will remain in the database forever.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

atuTrunkMode 1.3.6.1.4.1.11606.4.1.4.7
TRUNK - Trunk Mappped Address ============================= 1 - The 'atuPortVec' is the port vector assigned to this address. 2 - The data bits [7:4] of 'atuPortVec' is the Trunk ID assigned to this address. 'atuPortVec' bits [10:4] must be written as zero when this value is zet to a two(2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER portVectorMode(1), trunkIDMode(2)  

atuPortVecorTrunkID 1.3.6.1.4.1.11606.4.1.4.8
Port Vector/Trunk ID ==================== If the atuTrunk is zero, theses bits are used as the input Port Vector for ATU Load operations and it's the resulting Trunk ID for ATU load operations and it's the resulting Trunk ID from ATU GetNext operations.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

atuEntryState 1.3.6.1.4.1.11606.4.1.4.9
ATU Entry State =============== Used as the Entry State for ATU Load/Purge or Flush/Move operations and it is the resulting Entry State from ATU Get Next operations (GetNext is the only ATU operation supported in the devices). If theses equal to 0x0 then the atuOperation is a Purge or a Flush. If theses bits are not 0x0 then the atuOperation is a Load or a Move (a move atuOperation requires these bits to be 0x0F). On Get/Clear Violation Data atuOperation, theses bits return the Source Port ID(SPID) associated with the ATU violation that was just serviced. If SPID = 0xF the source of the violation was the CPU's register interface (i.e. the ATU was full during a CPU Load operation).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..15  

atuMACEntry 1.3.6.1.4.1.11606.4.1.4.10
ATU MAC Address Entry: ====================== Byte pattern as follow: Opaque data Location: 5 4 3 2 1 0 MAC Byte Location : [5][4][3][2][1][0]
Status: mandatory Access: read-write
OBJECT-TYPE    
  Opaque Size(6)  

oslam8g-Port 1.3.6.1.4.1.11606.4.2
OBJECT IDENTIFIER    

oslam8gPortSelect 1.3.6.1.4.1.11606.4.2.1
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

oslam8g-portCtrl 1.3.6.1.4.1.11606.4.2.2
OBJECT IDENTIFIER    

oslam8gPortForceFlowCtrl 1.3.6.1.4.1.11606.4.2.2.1
OSLAM-8G Port Force Flow Control Setting ======================================== 1 - Force No Flow Control 2 - Normal detection occurs 3 - Force Flow Control
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER forceNoFlowCtrl(1), normal(2), forceFlowCtrl(3)  


oslam8gPortForceDuplex 1.3.6.1.4.1.11606.4.2.2.3
OSLAM-8G Port Force Duplex Control ================================== 1 - Force Half-Duplex 2 - Normal duplex detection occurs. 3 - Force Full-Duplex
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER forceHalfDuplex(1), normal(2), forceFullDuplexx(3)  

oslam8gPortForceSpeed 1.3.6.1.4.1.11606.4.2.2.4
OSLAM-8G Port Force Speed ========================= 1 - 10Mbps 2 - 100Mbps 3 - 1000Mbps 4 - Speed is not forced. Normal speed detection occurs.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER speed10Mbps(1), speed100Mbps(2), speed1000Mbps(3), speedAutoDetect(4)  

oslam8gPortPortState 1.3.6.1.4.1.11606.4.2.2.5
OSLAM-8G Port's Port State =========================== This OID is used to manage a port to determine what kind of frames, if any, are allowed to enter or leave a port for simple bridge loop detection or 802.1D Spanning Tree. This OID value can be change at any time without disrupting frames currently in transmit. 1 - Disabled. The port is disabled and it will not receive or transmit any frames. The QC returns any pre-allocated ingress queue buffers when the port is in this mode. 2 - Blocking/Listening. OSLAM-8G examines all frames without learning any SAs, and discards all frames. 3 - Learning. OSLAM-8G will examine all frames, learning all SA address (except those from MGMT frames), and still discard all but MGMT frames. It will allow MGMT frames only to exit the port. 4 - Forwarding. OSLAM-8G examines all frames, learning SAs from all good frames (except those from MGMT frames), and receives and transmits all frames as a normal switch.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), blockingListening(2), learning(3), forwarding(4)  

oslam8gPortFwdUnknown 1.3.6.1.4.1.11606.4.2.2.6
OSLAM-8G Port Forward Unknown ============================= 1 - Unicast frames with unknown DAs will not egress out of this port. 2 - Normal operation occurs and unicast frames with unknown DA addresses are allowed to egress out of this port (assuming the VLAN settings allow the frame to egress this port too).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER blockUnicastWithUnknownDA(1), normalForward(2)  

oslam8gPortDefFwd 1.3.6.1.4.1.11606.4.2.2.7
OSLAM-8G Port Default Forward ============================= 1 - Multicast frames with unknown DAs do not egress from this port. 2 - Normal switch operation occurs and multicast frames with unknown DA addresses are allowed to egress out this port (assuming the VLAN settings allow the frame to egress this port too).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER blockMulticastWithUnknownDA(1), normalForward(2)  

oslam8gPortUseIPForPriority 1.3.6.1.4.1.11606.4.2.2.8
OSLAM-8G Port Use IP for Priority ================================= Use IPv4 TOS and/or DiffServ fields and/or IPv6 Traffic Class fields, if present, for priority data. 1 - Ignore IPv4 and IPv6 priority fields. 2 - Use IPv4 fields if the frame is IPv4 and use IPv6 fields if the frame is IPv6 for priority data.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER useIPv4AndIPv6Priority(1), useIPv4OrIPv6Priority(2)  

oslam8gPortUseCoreTag 1.3.6.1.4.1.11606.4.2.2.9
OSLAM-8G Port Use Core Tag ========================== Refer to 'oslam8gCoreTag' 1 - Ingressing frames are considered tagged if the 16-bits following the frame's source Address are 0x8100. 2 - Ingressing frames are considered tagged if the 16-bits following the frame's source Address are equal to 'oslam8gCoreTagType' NOTE: If a frame is Double Tagged and the first tag is removed (oslam8gPortDoubleTag) by matching the EtherType define by this bit, the resulting frame will be considered tagged only if the next 16 bits in the frame equal to 0x8100 (that is, the oslam8gCoreTagType is not used after the first tag is removed)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER normal(1), useCoreTag(2)  

oslam8gPortDoubleTag 1.3.6.1.4.1.11606.4.2.2.10
OSLAM-8G Port Double Tag ======================== Ingress Double Tag 2 - The ingressing frames are examined to see if they contain 802.3ac tag with the IEEE standard EtherType of 0x8100 or if they contain a tag with an EtherType defined in oslam8gCoreTag. The oslam8gCoreTag will be used if this port's oslam8gPortUseCoreTag is used. If the frames do contain the expected tag, the tag is removed (and the CRC is recomputed). Essentially, untagged frames remain untagged, single tagged frames become untagged and double tagged frames become single tagged. These now single tagged frames will be considered tagged only if its EtherType value is 0x8100 no matter what the EtherType value was found on the removed tag. No padding is performed so a tagged frame must be at least 68bytes in size or it will be discarded. 1 - Tagged frames are not modified when received. The Tag data that is removed from the frame can be ignored (i.e., the frame is treated as if the removed tag never existed) or the removed Tag data can be used for switching and priority decisions (i.e., the removed Tag's VID and PRI bits are internally assigned to the frame). The action that is taken is controlled by the oslam8gUseDoubleTagData
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER normal(1), useDoubleCoreTag(2)  

oslam8g-portRateCtrl 1.3.6.1.4.1.11606.4.2.3
OBJECT IDENTIFIER    

oslam8gPortEgressRate 1.3.6.1.4.1.11606.4.2.3.1
OSLAM-8G Port Egress Rate Limit ================================ Modify this port's effective transmission rate. This support 62kbps to 256Mbps. Formula to limit the Egress data rate: EgressRate = 8 bits/ (32ns * Egress Rate bits/sec) Where, => Egress Rate is in bits per second. For example: ============ For 256Kbps rate the value of this oslam8gPortEgressRate should be: = 8/(32ns * 256Kbps) = 976 The value to be programmed for this OID is 976. 976 is actually equated to 256.14Kbps
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4095  

oslam8gPortIngressLimitMode 1.3.6.1.4.1.11606.4.2.3.2
OSLAM-8G Port Ingress Limit Mode ================================ Determine what kinds of frames are limited and counted against Ingress limiting. 1 - Limit and count all frames. 2 - Limit and count Broadcast, Multicast and flooded unicast frames. 3 - Limit and count Broadcast and Multicast frames only. 4 - Limit and count Broadcast frames only. NOTE: If a frame is not limited by the above setting, its size is not counted against the limit for the other frames.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER limitAllFrames(1), limitBroadcastMulticastUnicastFrame(2), limitBroadcastMulticastFrame(3), limitBroadcastFrame(4)  

oslam8gPortIngressPri3Rate 1.3.6.1.4.1.11606.4.2.3.3
OSLAM-8G Port Priority 3 Rate Control ===================================== Priority 3 frames are discarded after the ingress rate selected below is reached or exceeded: 1 - Use the same rate as oslam8gPortIngressPri2Rate 2 - Use twice the rate as oslam8gPortIngressPri2Rate (but no faster than the port's speed)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER useIngressPri2Rate(1), useTwiceIngressPri2Rate(2)  

oslam8gPortIngressPri2Rate 1.3.6.1.4.1.11606.4.2.3.4
OSLAM-8G Port Priority 2 Rate Control ===================================== Priority 2 frames are discarded after the ingress rate selected below is reached or exceeded: 1 - Use the same rate as oslam8gPortIngressPri1Rate 2 - Use twice the rate as oslam8gPortIngressPri1Rate (but no faster than the port's speed)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER useIngressPri1Rate(1), useTwiceIngressPri1Rate(2)  

oslam8gPortIngressPri1Rate 1.3.6.1.4.1.11606.4.2.3.5
OSLAM-8G Port Priority 1 Rate Control ===================================== Priority 1 frames are discarded after the ingress rate selected below is reached or exceeded: 1 - Use the same rate as oslam8gPortIngressPri0Rate 2 - Use twice the rate as oslam8gPortIngressPri0Rate (but no faster than the port's speed)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER useIngressPri0Rate(1), useTwiceIngressPri0Rate(2)  

oslam8gPortIngressPri0Rate 1.3.6.1.4.1.11606.4.2.3.6
OSLAM-8G Port Priority 0 Rate Control ===================================== Priority 1 frames are discarded after the ingress rate selected below is reached or exceeded: OSLAM-8G use the following formula to calculate rate limiting: Pri0Rate = 8 bits/ (32ns * Ingress Rate bits/sec) Where, => Ingress Rate is in bits per second. For example: ============ For 128Kbps rate the value of this oslam8gPortEgressRate should be: = 8/(32ns * 128Kbps) = 1953
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4095  

oslam8g-PortVLAN 1.3.6.1.4.1.11606.4.2.4
OBJECT IDENTIFIER    

oslam8gPortUseTag 1.3.6.1.4.1.11606.4.2.4.1
OSLAM-8G Port Use Tag ===================== Use IEEE Tags. Use IEEE 802.1p Traffic Class field for priority data if the frame is an IEEE 802.3ac tagged frame. 1 - Ignore IEEE 802.1p tag fields even it the frame is tagged. In this mode, tagged frames that enter this port and egress the OSLAM-8G tagged are re-tagged with this port's default priority bits, if no other priorities are determined fro the frame (i.e., the frame's IP priority and/or other priority overrides). This works as a Force Default Priority function on tagged frames. 2 - Use IEEE 802.1p tag Traffic Class for priority data if the frame is tagged.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ignoreIEEE802dot1pTag(1), useIEEE802dot1pTag(2)  

oslam8gPortPortMembership 1.3.6.1.4.1.11606.4.2.4.2
OSLAM-8G Port's Port Membership =============================== Port based VLAN Table. The bits in this value are used to restrict which output ports this input port can send frames to. This value are used for all frames even if 802.1Q is enabled on this port or if ProtectedPort is enabled on this port. These bits restrict where a port can send frames (unless a oslam8gPortVLANTunnel frame is being received. => To send frames to Port 0, bit 0 of this register must be a one. => To send frames to Port 1, bit 1 of this register must be a one. etc.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2047  

oslam8gPortDefPri 1.3.6.1.4.1.11606.4.2.4.3
OSLAM-8G Port Default Priority ============================== Used as the default ingress priority to use when no other priority information is available (neither is the frame IEEE Tagged, nor is it an IPv4 nor an IPv6 frame - or the frame is a priority type that is currently disabled (see oslam8gPortUseIPPriority and oslam8gPortUseTag) and no other priority overrides are active on this frame. The default priority are remapped by the oslam8gPortPriRemap prior being used.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..7  

oslam8gPort802dot1QMode 1.3.6.1.4.1.11606.4.2.4.4
OSLAM-8G Port 802.1Q Mode ========================= IEEE 802.1Q Mode for this port. These bits determine if 802.1Q based VLANs are used along with port based VLANs for this Ingress port. If also determines the action to be taken if an 802.1Q VLAN Violation is detected. 1 - 802.1Q disabled. Use Port Based VLANs only. The oslam8gPortMembership and oslam8gPortDefVID assigned to the frame during ingress determine which Egress ports this Ingress is allowed to switch frames to for all frames. 2 - Fallback. Enable 802.1Q for this Ingress port. Do not discard Ingress Membership violations and use the oslam8gPortMembership if the frame's VID is not contained in the VTU. 3 - Check. Enabled 802.1Q for this Ingress port. Do not discard Ingress Membership violation but discard the frame if its VID is not contained in the VTU. 4 - Secure. Enabled 802.1Q for this Ingress port. Do not discard Ingress Membership violations and discard frames whose VID is not contained in the VTU.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER portBasedVLANOnly(1), fallback802dot1Q(2), check802dot1Q(3), secure802dot1Q(4)  

oslam8gPortTagUntagDiscard 1.3.6.1.4.1.11606.4.2.4.5
OSLAM-8G Port Tagged/Untagged Discard Mode ========================================== 1 - No discard of Frames 2 - Only Discard Untagged Frames. All non-MGMT frames that are processed as untagged are discarded as they entering this switch port. This test is performed after Ingress Double Tag removal (if enabled). 3 - Only Discard Tagged Frames. All non-MGMT frames that are processed as tagged are discarded as they entering this switch port. This test is performed after Ingress Double Tag removal (if enabled). Priority only tagged frames (with a VID of 0x00) are considered tagged. 4 - Both Discard Tagged and Untagged frames.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noDiscard(1), discardUnTaggedFrames(2), discardTaggedFrames(3), discardBoth(4)  

oslam8gPortDefVID 1.3.6.1.4.1.11606.4.2.4.6
OSLAM-8G Port Default VLAN Identifier ===================================== When 802.1Q is enabled on this port this value is used as the IEEE Tagged VID added to untagged or priority tagged frames during egress that ingressed from this port. It is also used as a tagged frame's VID if the frame's VID was 0 (i.e., it is a priority tagged frame) or if the port's oslam8gPortForceDefVID is set to one. When 802.1Q is disabled on this port, this value field is assigned to all frames entering the port (if are tagged or untagged). This assignment is used internal to the switch, so only Port Based VLANs can be supported.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4095  

oslam8gPortVLANTunnel 1.3.6.1.4.1.11606.4.2.4.7
OSLAM-8G Port VLAN Tunnel ========================= 1 - The port based VLANs defined in oslam8gPortPortMembership, 802.1Q VLANs defined in the oslam8g-802dot1QVLAN (if 802.1Q is enabled) and oslam8gTrunkMask are enforced for ALL frames. 2 - The port based oslam8gPortPortMembership, 802.1Q VLAN membership masking and oslam8gTrunkMask is bypassed for any frame entering this port with a DA that is currently 'static' in the oslam8g-atu. This applies to unicast as well as multicast frames.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER vlanNoTunnelling(1), vlanTunnelling(2)  

oslam8gPortVTUPriOverride 1.3.6.1.4.1.11606.4.2.4.8
OSLAM-8G Port VTU Priority Override =================================== 1 - Normal frame priority processing occurs. 2 - The VTU priority overrides can occur on this port. A VTU priority override occurs when the determined VID of a frame resuls in a VID whose oslam8gVTUVIDPRIOverride in the VTU VLAN database is set. When this occurs the VIDPRI value assigned to the frame's VID is used to overrite the frames previously determined priority. If the frame egresses tagged the priority in the frame will be this new VIDPRI value. When used the upper two bits of the VIDPRI priority determine the Egress Queue the frame is switched into. THE VTU Priority Override has higher priority than the port's Default Priority and the frame's IEEE and/or IP priorities. The priority determined by the frame's VID can be overridden, however, by the frame's SA and/or DA prority Overrides.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER normalPriority(1), vtuPriOverride(2)  

oslam8gPortForceDefVID 1.3.6.1.4.1.11606.4.2.4.9
OSLAM-8G Port Force Default VID =============================== For to use Default VID. When 802.1Q is enabled on this port and 1 - All IEEE 802.3ac Tagged frames with a non-zero VID used the frame's VID unmodified. 2 - All ingress frames with IEEE 802.3ac Tags have their VID ignored and the port's oslam8gPortDefaultVID is used and replaced into the frame instead. When 802.1Q is disabled on this port, this bit has no effect.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER vidNormal(1), forceDefaultVID(2)  

oslam8gEgressMode 1.3.6.1.4.1.11606.4.2.4.10
OSLAM-8G Port Egress Mode ========================= The first three Egrress Modes are used as the default Egress mode for frames whose VID is not valid in the oslam8g-802dot1QVLAN or if 802.1Q is disabled on the port. The fourth Egress Mode is applied to all frames all the time (if selected) even if 802.1Q is enabled on the port. 1 - Default to Normal mode. Frames are transmitted unmodified. 2 - Default to Transmit all frames Untagged. Remove the tag from any tagged frame. 3 - Default to Transmit all frames Tagged. Add a tag to any untagged frame. 4 - Always add a Tag (or Egress Double Tag). This setting is not a default setting. It ignores the MemberTag in vtuData of oslam8g-802dot1QVLAN for this port. The EtherType used for these inserted tags come from oslam8gCoreTag.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER egressNormal(1), egressUntaggedRemoveTaggedFrame(2), egressTagAddToUntaggedFrame(3), egressAddAlways(4)  

oslam8gPortPriRemap 1.3.6.1.4.1.11606.4.2.4.11
OSLAM-8G Port IEEE Priority Remapping ==================================== Byte#: 3 2 1 0 Format: [TagRemap7:TagRemap6][TagRemap5:TagRemap4][TagRemap3:TagRemap2][TagRemap1:TagRemap0] TagRemap0: Tag Remap 0. All IEEE tagged frames with a priority of 0 get this value as the frame's new priority inside the switch. If a tagged frame egresses the switch tagged, this new priority is written to the frame's tag. TagRemap1: Tag Remap 1. All IEEE tagged frames with a priority of 1 get this value as the frame's new priority inside the switch. If a tagged frame egresses the switch tagged, this new priority is written to the frame's tag. TagRemapX: Tag Remap X. All IEEE tagged frames with a priority of X get this value as the frame's new priority inside the switch. If a tagged frame egresses the switch tagged, this new priority is written to the frame's tag.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Opaque Size(4)  

oslam8g-portStatus 1.3.6.1.4.1.11606.4.2.5
OBJECT IDENTIFIER    

oslam8gPortLinkStatus 1.3.6.1.4.1.11606.4.2.5.1
Link Status: ============ This indicates the link status of the selected port 1 - Link is down 2 - Link is Up
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER linkDown(1), linkUp(2)  

oslam8gPortDuplexStatus 1.3.6.1.4.1.11606.4.2.5.2
Duplex Mode: ============ Valid if link status is up. 1 - Half-Duplex 2 - Full-Duplex
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER halfDuplex(1), fullDuplex(2)  

oslam8gPortSpeedStatus 1.3.6.1.4.1.11606.4.2.5.3
Speed Mode: =========== Valid if link status is up. 1 - 10MBps 2 - 100MBps 3 - 1000MBps 4 - Reserved for future used
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER speed10Mbps(1), speed100MBps(2), speed1000MBps(3), speedReserved(4)  

oslam8g-portRMON 1.3.6.1.4.1.11606.4.2.6
OBJECT IDENTIFIER    

oslam8gPortRMONIngress 1.3.6.1.4.1.11606.4.2.6.1
OBJECT IDENTIFIER    

oslam8gPortInGoodOctetsLo 1.3.6.1.4.1.11606.4.2.6.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

oslam8gPortInGoodOctetsHi 1.3.6.1.4.1.11606.4.2.6.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

oslam8gPortInBadOctets 1.3.6.1.4.1.11606.4.2.6.1.3
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

oslam8gPortInUnicast 1.3.6.1.4.1.11606.4.2.6.1.4
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

oslam8gPortInBroadcasts 1.3.6.1.4.1.11606.4.2.6.1.5
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

oslam8gPortInMulticasts 1.3.6.1.4.1.11606.4.2.6.1.6
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

oslam8gPortInPause 1.3.6.1.4.1.11606.4.2.6.1.7
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

oslam8gPortInUndersize 1.3.6.1.4.1.11606.4.2.6.1.8
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

oslam8gPortInFragments 1.3.6.1.4.1.11606.4.2.6.1.9
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

oslam8gPortInOversize 1.3.6.1.4.1.11606.4.2.6.1.10
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

oslam8gPortInJabber 1.3.6.1.4.1.11606.4.2.6.1.11
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

oslam8gPortInRxErr 1.3.6.1.4.1.11606.4.2.6.1.12
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

oslam8gPortInFCSErr 1.3.6.1.4.1.11606.4.2.6.1.13
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

oslam8gPortInDiscards 1.3.6.1.4.1.11606.4.2.6.1.14
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

oslam8gPortInFiltered 1.3.6.1.4.1.11606.4.2.6.1.15
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

oslam8gPortRMONEgress 1.3.6.1.4.1.11606.4.2.6.2
OBJECT IDENTIFIER    

oslam8gPortOutOctetsLo 1.3.6.1.4.1.11606.4.2.6.2.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

oslam8gPortOutOctetsHi 1.3.6.1.4.1.11606.4.2.6.2.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

oslam8gPortOutUnicast 1.3.6.1.4.1.11606.4.2.6.2.3
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

oslam8gPortOutBroadcasts 1.3.6.1.4.1.11606.4.2.6.2.4
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

oslam8gPortOutMulticasts 1.3.6.1.4.1.11606.4.2.6.2.5
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

oslam8gPortOutPause 1.3.6.1.4.1.11606.4.2.6.2.6
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

oslam8gPortOutExcessive 1.3.6.1.4.1.11606.4.2.6.2.7
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

oslam8gPortOutCollisions 1.3.6.1.4.1.11606.4.2.6.2.8
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

oslam8gPortOutDeferred 1.3.6.1.4.1.11606.4.2.6.2.9
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

oslam8gPortOutSingle 1.3.6.1.4.1.11606.4.2.6.2.10
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

oslam8gPortOutMultiple 1.3.6.1.4.1.11606.4.2.6.2.11
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

oslam8gPortOutFCSErr 1.3.6.1.4.1.11606.4.2.6.2.12
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

oslam8gPortOutLate 1.3.6.1.4.1.11606.4.2.6.2.13
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

oslam8gPortOutFiltered 1.3.6.1.4.1.11606.4.2.6.2.14
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

oslam8gPortHistogram 1.3.6.1.4.1.11606.4.2.6.3
OBJECT IDENTIFIER    

oslam8gPortHistogramMode 1.3.6.1.4.1.11606.4.2.6.3.1
Histogram Counters Mode: ======================== The Histogram mode control how the Histogram counters work as follows. 1 - Count received frames only 2 - Count transmitted frames only 3 - Count receive and tranmitted frames
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER countRxFramesOnly(1), countTxFramesOnly(2), countRxTxFrames(3)  

oslam8gPortOut64Octets 1.3.6.1.4.1.11606.4.2.6.3.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

oslam8gPortOut65to127Octets 1.3.6.1.4.1.11606.4.2.6.3.3
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

oslam8gPortOut128to255Octets 1.3.6.1.4.1.11606.4.2.6.3.4
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

oslam8gPortOut256to511Octets 1.3.6.1.4.1.11606.4.2.6.3.5
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

oslam8gPortOut512to1023Octets 1.3.6.1.4.1.11606.4.2.6.3.6
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

oslam8gPortOut1024toMaxOctets 1.3.6.1.4.1.11606.4.2.6.3.7
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fpcm 1.3.6.1.4.1.11606.5
OBJECT IDENTIFIER    

targetNodeAddress 1.3.6.1.4.1.11606.5.1
Target Node Address: ==================== FPCM is a broadcast device. 10 digits decimal address required to access the target optical node. Value of 4294967295 represent a broadcast address i.e. message will be send to all connected node. This value is the serial number of the ODN4P-ABC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(10)  

odn4pAccess 1.3.6.1.4.1.11606.5.2
OBJECT IDENTIFIER    

odn4pABSwitchingMode 1.3.6.1.4.1.11606.5.2.1
AB Switching Mode: ================== The mode of operation for ODN4P-AB. Available operation mode are: - AUTOMATIC - MANUAL
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER manual(1), automatic(2)  

odn4pChannelSelect 1.3.6.1.4.1.11606.5.2.2
Channel Select: =============== The channel to be selected by the AB redundancy switch. Upon changing the channel, AB operation mode at the target device will change to MANUAL mode automatically.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER priOpt(1), secOpt(2)  

odn4pSwitchingHysteresis 1.3.6.1.4.1.11606.5.2.3
Switch Hysteresis: ================== Primary Optical recovery level.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER neg3dot5dBmV(0), neg3dot0dBmV(1), neg2dot5dBmV(2), neg2dot0dBmV(3), neg1dot5dBmV(4), neg1dot0dBmV(5), neg0dot5dBmV(6), neg0dot0dBmV(7)  

odn4pPrimarySwitchOverTime 1.3.6.1.4.1.11606.5.2.4
Primary switch-over time: ========================= The number of second wait required before change of state
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..15  

odn4pSecondarySwitchOverTime 1.3.6.1.4.1.11606.5.2.5
Secondary switch-over time: =========================== The number of second wait required before change of state
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..15  

odn4pAttenuator1 1.3.6.1.4.1.11606.5.2.6
Attenuator 1: ============= Attenuation used for ingress control. Unit is in 1dB step. Acceptable value range: 2-40dB
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 2..40  

odn4pAttenuator2 1.3.6.1.4.1.11606.5.2.7
Attenuator 2: ============= Attenuation used for ingress control. Unit is in 1dB step. Acceptable value range: 2-40dB
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 2..40  

odn4pAttenuator3 1.3.6.1.4.1.11606.5.2.8
Attenuator 3: ============= Attenuation used for ingress control. Unit is in 1dB step. Acceptable value range: 2-40dB
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 2..40  

odn4pAttenuator4 1.3.6.1.4.1.11606.5.2.9
Attenuator 4: ============= Attenuation used for ingress control. Unit is in 1dB step. Acceptable value range: 2-40dB
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 2..40  

odn4pHomeFskChannel 1.3.6.1.4.1.11606.5.2.10
Remote node FSK home channel: ============================= Each network may use different default FSK channel. This is the default FSK channel to be managed by operator. Optical node always tune to home channel prior to agility.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..100  

odn4pFskMode 1.3.6.1.4.1.11606.5.2.11
FSK Operating mode ================== Force FSK to operate in either FIX or AGILE mode. FIX - FSK receiver always try to lock to the known FSK frequency AGILE - Always search for an FSK channel that is capable of decoding data
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER fskFix(1), fskAgile(2)  

odn4pLoopTest 1.3.6.1.4.1.11606.5.2.12
ODN4P LOOP TEST =============== Acceptable value is 0-255 or 8-bit number. Value between between 1..255 will be display on the connected RPQRM of the selected channel if this OID has been iniated. Set value to 0xFB will clear loopback test and normal data will then be seen in the RPQRM. Operator should only use value between 0x70 to 0x7F for testing Other values are reserved for NETCRAFT
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER uidSrcAddr0(22), uidSrcAddr1(23), uidSrcAddr2(24), uidSrcAddr3(25), uidAddr0(26), uidAddr1(27), uidAddr2(28), uidAddr3(29), uidMajorVer(30), uidMinorVer(31), uidAtten0(33), uidAtten1(34), uidAtten2(35), uidAtten3(36), uidFSKCh(48), uidFSKMode(50), uidPassTest112(112), uidPassTest113(113), uidPassTest114(114), uidPassTest115(115), uidPassTest116(116), uidPassTest117(117), uidPassTest118(118), uidPassTest119(119), uidPassTest120(120), uidPassTest121(121), uidPassTest122(122), uidPassTest123(123), uidPassTest124(124), uidPassTest125(125), uidPassTest126(126), uidPassTest127(127), uidModeSel(129), uidInpSel(130), uidPriRefLvl(131), uidPriSwtTime(132), uidSecSwtTime(133), uidModeChgCnt(134), uidInpChgCnt(135), uidClearTest(251)  

nodeAccess 1.3.6.1.4.1.11606.5.3
OBJECT IDENTIFIER    

nodeAccessDataLength 1.3.6.1.4.1.11606.5.3.1
Node Access Control Data Length: ================================ This usually used by remote management software (NMS3) Operator should ignore or do not change this OID value.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

nodeAccessData 1.3.6.1.4.1.11606.5.3.2
Node Access Control Data: ========================= This usually used by remote management software (NMS3) Operator should ignore or do not change this OID value.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Opaque Size(0..32)  

nodeAccessCmd 1.3.6.1.4.1.11606.5.3.3
Node Access Control Command: ============================ This usually used by remote management software (NMS3) Operator should ignore or do not change this OID value.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

fpcmCtrl 1.3.6.1.4.1.11606.5.4
OBJECT IDENTIFIER    

fpcmFSKChannel 1.3.6.1.4.1.11606.5.4.1
FSK Channel modulated by FPCM: ============================== Acceptable FSK channel range 0-100. FSK modulation range 80-90MHz (Channel 0-100 respectively)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..100  

fpcmRFLevel 1.3.6.1.4.1.11606.5.4.2
FPCM RF level ============= RF level setting in 1dBmV scale. Current supported value is 25-45dBmV
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 25..45  

mau 1.3.6.1.4.1.11606.6
OBJECT IDENTIFIER    

mauProductInfo 1.3.6.1.4.1.11606.6.1
OBJECT IDENTIFIER    

mauProductModelName 1.3.6.1.4.1.11606.6.1.1
Product model name
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

mauProductVersion 1.3.6.1.4.1.11606.6.1.2
Product version number
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

mauProductVersionDate 1.3.6.1.4.1.11606.6.1.3
Product build date
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

mauProductMAC 1.3.6.1.4.1.11606.6.1.4
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6)  

mauProductSerialNumber 1.3.6.1.4.1.11606.6.1.5
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6)  

mauStatus 1.3.6.1.4.1.11606.6.2
OBJECT IDENTIFIER    

mauStatusVACType 1.3.6.1.4.1.11606.6.2.1
VAC input type. e.g. '220V'
Status: mandatory Access: read-only
OBJECT-TYPE    
  TypePowerSupply  

mauStatus5V 1.3.6.1.4.1.11606.6.2.2
+5V supply voltage level. Unit is in Volt e.g. 4.92V
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

mauStatus12V 1.3.6.1.4.1.11606.6.2.3
+12V supply voltage level. Unit is in Volt e.g. 12.00V
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

mauStatus24V 1.3.6.1.4.1.11606.6.2.4
+24V supply voltage level. Unit is in Volt e.g. 24.10V
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

mauStatusInputOpticalPower 1.3.6.1.4.1.11606.6.2.5
Optical input power level. Unit is in dBm e.g. -2.05dBm
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

mauStatusOutputOpticalPower 1.3.6.1.4.1.11606.6.2.6
Optical input power level. Unit is in dBm e.g. -2.05dBm
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

mauStatusRFOutputPower 1.3.6.1.4.1.11606.6.2.7
Total RF output power level. Unit is in dBmV e.g. 41.23dBmV total or 25.00dBmV/Ch@42Ch.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

mauStatusTemperature 1.3.6.1.4.1.11606.6.2.8
Module internal temperature. Unit is in Degree Celsius e.g. 29.25C
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

mauStatusLid 1.3.6.1.4.1.11606.6.2.9
Device lid open/close status
Status: mandatory Access: read-only
OBJECT-TYPE    
  TypeTamper  

mauStatusONUInstalled 1.3.6.1.4.1.11606.6.2.10
EPON-ONU installed status.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TypeYesNo  

mauStatusMOCAInstalled 1.3.6.1.4.1.11606.6.2.11
MOCA installed status.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TypeYesNo  

mauStatusPLCInstalled 1.3.6.1.4.1.11606.6.2.12
PLC installed status.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TypeYesNo  

mauStatusLED 1.3.6.1.4.1.11606.6.2.13
Status LED
Status: mandatory Access: read-only
OBJECT-TYPE    
  TypeOnOff  

mauStatusGainControlLED 1.3.6.1.4.1.11606.6.2.14
Gain control LED (AGC/MGC) status. ON - AGC mode OFF - MGC mode
Status: mandatory Access: read-only
OBJECT-TYPE    
  TypeOnOff  

mauStatusOpticalInputHighLED 1.3.6.1.4.1.11606.6.2.15
Optical input high led indicator ON - Optical input is too high.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TypeOnOff  

mauStatusOpticalInputLowLED 1.3.6.1.4.1.11606.6.2.16
Optical input LOW led indicator ON - Optical input is too low.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TypeOnOff  

mauStatus5VMin 1.3.6.1.4.1.11606.6.2.17
+5V Supply MIN voltage alarm level
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

mauStatus5VMax 1.3.6.1.4.1.11606.6.2.18
+5V Supply MAX voltage alarm level
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

mauStatus12VMin 1.3.6.1.4.1.11606.6.2.19
+12V Supply MIN voltage alarm level
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

mauStatus12VMax 1.3.6.1.4.1.11606.6.2.20
+12V Supply MAX voltage alarm level
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

mauStatus24VMin 1.3.6.1.4.1.11606.6.2.21
+24V Supply MIN voltage alarm level
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

mauStatus24VMax 1.3.6.1.4.1.11606.6.2.22
+24V Supply MAX voltage alarm level
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

mauStatusInputOpticalPowerMin 1.3.6.1.4.1.11606.6.2.23
Optical Input Power MIN alarm level
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

mauStatusInputOpticalPowerMax 1.3.6.1.4.1.11606.6.2.24
Optical Input Power MAX alarm level
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

mauStatusOutputOpticalPowerMin 1.3.6.1.4.1.11606.6.2.25
Optical Output Power MIN alarm level
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

mauStatusOutputOpticalPowerMax 1.3.6.1.4.1.11606.6.2.26
Optical Output Power MAX alarm level
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

mauStatusTemperatureMin 1.3.6.1.4.1.11606.6.2.27
Temperature MIN alarm level
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

mauStatusTemperatureMax 1.3.6.1.4.1.11606.6.2.28
Temperature MAX alarm level
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

mauStatusGainControlMin 1.3.6.1.4.1.11606.6.2.29
Gain Control MIN Level
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

mauStatusGainControlMax 1.3.6.1.4.1.11606.6.2.30
Gain Control MAX Level
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

mauStatusAgcLock 1.3.6.1.4.1.11606.6.2.31
AGC lock when the controlled signal is within range. AGC unlock when agc cannot control the signal or signal is out of range for AGC to operate.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TypeAGCStatus  

mauControl 1.3.6.1.4.1.11606.6.3
OBJECT IDENTIFIER    

mauGainControlMode 1.3.6.1.4.1.11606.6.3.1
RF gain control setting. 1dB control step. Control range to be adviced.
Status: mandatory Access: read-write
OBJECT-TYPE    
  TypeGainMode  

mauTrapEnabled 1.3.6.1.4.1.11606.6.3.2
Indicates if this trap entry is enabled or not.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER trapDisabled(1), trapEnabled(2)  

mauPrimaryCommunity 1.3.6.1.4.1.11606.6.3.3
Primary Community String to be used by agent for SNMP GET/SET for mauTrapPrimaryReceiverIPAddress
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

mauSecondaryCommunity 1.3.6.1.4.1.11606.6.3.4
Secondary Community String to be used by agent for SNMP GET/SET for mauTrapSecondaryReceiverIPAddress
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

mauPrimaryTrapReceiverIPAddress 1.3.6.1.4.1.11606.6.3.5
The primary Trap Receiver station IP address
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

mauSecondaryTrapReceiverIPAddress 1.3.6.1.4.1.11606.6.3.6
The secondary Trap Receiver station IP address
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

mauTraps 1.3.6.1.4.1.11606.6.4
OBJECT IDENTIFIER    

mauTrapMessageDescr 1.3.6.1.4.1.11606.6.4.1
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

lte153 1.3.6.1.4.1.11606.7
OBJECT IDENTIFIER    

lte153Laser 1.3.6.1.4.1.11606.7.1
OBJECT IDENTIFIER    

tagID 1.3.6.1.4.1.11606.7.1.1
Displays the tag name of the device in human-readable format as set by user.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..23)  

modelNumber 1.3.6.1.4.1.11606.7.1.2
Displays the name of the device model number in human-readable format as set from the factory.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..23)  

mfgDate 1.3.6.1.4.1.11606.7.1.3
Displays the manufacturing date in human-readable format as set from the factory.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..23)  

serialNum 1.3.6.1.4.1.11606.7.1.4
Displays the serial number in human-readable format as set from the factory.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..23)  

firmwareRev 1.3.6.1.4.1.11606.7.1.5
Displays the software revision of the device in human-readable format.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..23)  

engRev 1.3.6.1.4.1.11606.7.1.6
Displays the engineering revision in human-readable format as set from the factory.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..23)  

systemTemp 1.3.6.1.4.1.11606.7.1.7
Returns the unit temperature.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -500..1200  

laserCurrent 1.3.6.1.4.1.11606.7.1.8
Returns measured laser bias current.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..1250  

laserTemperature 1.3.6.1.4.1.11606.7.1.9
Returns the measured laser temperature.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -500..800  

inputRFLevel 1.3.6.1.4.1.11606.7.1.10
Returns the input RF level.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1000..100  

compositeRFLevel 1.3.6.1.4.1.11606.7.1.11
Returns the measured composite RF level.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1000..100  

opticalPowerOut1 1.3.6.1.4.1.11606.7.1.12
Returns the optical power output for port 1.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1000..200  

opticalPowerOut2 1.3.6.1.4.1.11606.7.1.13
Returns the optical power output for port 2.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1000..200  

tecCurrent 1.3.6.1.4.1.11606.7.1.14
Returns the current of thermoelectric cooler inside the laser asssembly.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -25000..25000  

attenuationSet 1.3.6.1.4.1.11606.7.1.15
Manual mode RF attenuator setpoint.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -70..30  

omiSetpoint 1.3.6.1.4.1.11606.7.1.16
Optical modulation index is implemented for CW or Video AGC modes as RF attenuator setpoint.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -30..30  

agcMode 1.3.6.1.4.1.11606.7.1.17
Returns the AGC mode.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER undefined(0), manual(1), cw(2), video(3), invalidMode(4)  

sbsSuppression 1.3.6.1.4.1.11606.7.1.18
SBS suppression level.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 140..180  

fiberDispersionCntl 1.3.6.1.4.1.11606.7.1.19
Fiber dispersion compensation On/Off control.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER undefined(0), off(1), on(2)  

fiberDispersionGain 1.3.6.1.4.1.11606.7.1.20
Fiber dispersion gain compensation.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -40..40  

fiberDispersionPhase 1.3.6.1.4.1.11606.7.1.21
Fiber dispersion phase compensation.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -40..40  

fiberDispersionSlope 1.3.6.1.4.1.11606.7.1.22
Fiber dispersion slope compensation.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -40..40  

laserOnOff 1.3.6.1.4.1.11606.7.1.23
returns the active laser On/Off status.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER undefined(0), off(1), on(2)  

keyswitch 1.3.6.1.4.1.11606.7.1.24
Returns the status of the front panel keyswitch.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER undefined(0), off(1), on(2)  

remoteLaserControl 1.3.6.1.4.1.11606.7.1.25
Remote laser On/Off control.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER undefined(0), off(1), on(2)  

resetCause 1.3.6.1.4.1.11606.7.1.26
This object reports the cause of the last reset.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER undefined(0), other(1), powerup(2), command(3), watchdog(4), craft(5)  

resetControl 1.3.6.1.4.1.11606.7.1.27
This object is used to reset the transmitter module by writing a 1 to it. Other values written to the object have no effect. Reading the object returns a 1 and has no effect on the module.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER undefined(0), reset(1)  

sbs2GHzPower 1.3.6.1.4.1.11606.7.1.28
2GHz SBS output power level.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -300..300  

sbs6GHzPower 1.3.6.1.4.1.11606.7.1.29
6GHz SBS output power level.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -300..300  

monitor5v 1.3.6.1.4.1.11606.7.1.30
Returns the measured value of the +5V supply.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..70  

monitor12v 1.3.6.1.4.1.11606.7.1.31
Returns the measured value of the +12V supply.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..150  

monitor24v 1.3.6.1.4.1.11606.7.1.32
Returns the measured value of the +24V supply.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..300  

monitorM5v 1.3.6.1.4.1.11606.7.1.33
Returns the measured value of the -5V supply.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -70..70  

monitorM12v 1.3.6.1.4.1.11606.7.1.34
Returns the measured value of the -12V supply.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -150..150  

unitStatusEnable 1.3.6.1.4.1.11606.7.1.35
Indicates the unit status alarm enable. This value is bit encoded therefore it is capable of indicating multiple alarm enable conditions. The bits are defined as follows: 0 1 2 3 4 5 6 7 +-------+-------+-------+-------+-------+-------+-------+-------+ |System |System | Laser | Laser | Laser | Laser | Input | Input | | Temp | Temp |Current|Current| Temp | Temp | RF | RF | | High | Low | High | Low | High | Low | Level | Level | | | | | | | | High | Low | +-------+-------+-------+-------+-------+-------+-------+-------+ 8 9 10 11 12 13 14 15 +-------+-------+-------+-------+-------+-------+-------+-------+ |Optical|Optical| TEC | AGC |Key in |Remote | | | | Power | Power |Current| Unlock| Off | Off | | | | Out | Out | High | |Position Mode | | | | High | Low | | | | Set | | | +-------+-------+-------+-------+-------+-------+-------+-------+
Status: current Access: read-write
OBJECT-TYPE    
  BITS systemTempHigh(0), systemTempLow(1), laserCurrentHigh(2), laserCurrentLow(3), laserTempHigh(4), laserTempLow(5), inputRFHigh(6), inputRFLow(7), opticalPowerHigh(8), opticalPowerLow(9), tecCurrentHigh(10), agcUnlock(11), keyInOffPosition(12), remoteOffModeSet(13)  

unitStatusMajor 1.3.6.1.4.1.11606.7.1.36
Returns a bit mapped status word where each bit set (as defined below) indicates a specific active alarm: 0 1 2 3 4 5 6 7 +-------+-------+-------+-------+-------+-------+-------+-------+ |System |System | Laser | Laser | Laser | Laser | Input | Input | | Temp | Temp |Current|Current| Temp | Temp | RF | RF | | High | Low | High | Low | High | Low | Level | Level | | | | | | | | High | Low | +-------+-------+-------+-------+-------+-------+-------+-------+ 8 9 10 11 12 13 14 15 +-------+-------+-------+-------+-------+-------+-------+-------+ |Optical|Optical| TEC | AGC |Key in |Remote | | | | Power | Power |Current| Unlock| Off | Off | | | | Out | Out | High | |Position Mode | | | | | | | | | Set | | | +-------+-------+-------+-------+-------+-------+-------+-------+
Status: current Access: read-only
OBJECT-TYPE    
  BITS systemTempHigh(0), systemTempLow(1), laserCurrentHigh(2), laserCurrentLow(3), laserTempHigh(4), laserTempLow(5), inputRFHigh(6), inputRFLow(7), opticalPowerHigh(8), opticalPowerLow(9), tecCurrentHigh(10), agcUnlock(11), keyInOffPosition(12), remoteOffModeSet(13)  

unitStatusMinor 1.3.6.1.4.1.11606.7.1.37
Returns a bit mapped status word where each bit set (as defined below) indicates a specific active warning: 0 1 2 3 4 5 6 7 +-------+-------+-------+-------+-------+-------+-------+-------+ |System |System | Laser | Laser | Laser | Laser | Input | Input | | Temp | Temp |Current|Current| Temp | Temp | RF | RF | | High | Low | High | Low | High | Low | Level | Level | | | | | | | | High | Low | +-------+-------+-------+-------+-------+-------+-------+-------+ 8 9 10 11 12 13 14 15 +-------+-------+-------+-------+-------+-------+-------+-------+ |Optical|Optical| TEC | AGC |Key in |Remote | | | | Power | Power |Current| Unlock| Off | Off | | | | Out | Out | High | |Position Mode | | | | High | Low | | | | Set | | | +-------+-------+-------+-------+-------+-------+-------+-------+
Status: current Access: read-only
OBJECT-TYPE    
  BITS systemTempHigh(0), systemTempLow(1), laserCurrentHigh(2), laserCurrentLow(3), laserTempHigh(4), laserTempLow(5), inputRFHigh(6), inputRFLow(7), opticalPowerHigh(8), opticalPowerLow(9), tecCurrentHigh(10), agcUnlock(11), keyInOffPosition(12), remoteOffModeSet(13)  

unitStatusHistory 1.3.6.1.4.1.11606.7.1.38
Returns a bit mapped status word where each bit set (as defined below) indicates a an alarm had occurred since the last power up or clear: 0 1 2 3 4 5 6 7 +-------+-------+-------+-------+-------+-------+-------+-------+ |System |System | Laser | Laser | Laser | Laser | Input | Input | | Temp | Temp |Current|Current| Temp | Temp | RF | RF | | High | Low | High | Low | High | Low | Level | Level | | | | | | | | High | Low | +-------+-------+-------+-------+-------+-------+-------+-------+ 8 9 10 11 12 13 14 15 +-------+-------+-------+-------+-------+-------+-------+-------+ |Optical|Optical| TEC | AGC |Key in |Remote | | | | Power | Power |Current| Unlock| Off | Off | | | | Out | Out | High | |Position Mode | | | | High | Low | | | | Set | | | +-------+-------+-------+-------+-------+-------+-------+-------+ Clear status history by writing a value of 0.
Status: current Access: read-write
OBJECT-TYPE    
  BITS systemTempHigh(0), systemTempLow(1), laserCurrentHigh(2), laserCurrentLow(3), laserTempHigh(4), laserTempLow(5), inputRFHigh(6), inputRFLow(7), opticalPowerHigh(8), opticalPowerLow(9), tecCurrentHigh(10), agcUnlock(11), keyInOffPosition(12), remoteOffModeSet(13)  

miscStatusEnable 1.3.6.1.4.1.11606.7.1.39
Indicates the miscellaneous status alarm enable. This value is bit encoded therefore it is capable of indicating multiple alarm enable conditions. The bits are defined as follows: 0 1 2 3 4 5 6 7 +-------+-------+-------+-------+-------+-------+-------+-------+ | 2 GHz | 2 GHz | 6 GHz | 6 GHz |System |System |System |System | | SBS | SBS | SBS | SBS | +5V | +5V | +12V | +12V | | Power | Power | Power | Power | Power | Power | Power | Power | | High | Low | High | Low | High | Low | High | Low | +-------+-------+-------+-------+-------+-------+-------+-------+ 8 9 10 11 12 13 14 15 +-------+-------+-------+-------+-------+-------+-------+-------+ |System |System |System |System |System |System | Comm | | | +24V | +24V | -5V | -5V | -12V | -12V |Failure| | | Power | Power | Power | Power | Power | Power | | | | High | Low | High | Low | High | Low | | | +-------+-------+-------+-------+-------+-------+-------+-------+ 16 17 18 19 20 21 22 23 +-------+-------+-------+-------+-------+-------+-------+-------+ | Power | Power |Cooling|Cooling| | | | | | Supply| Supply| Fan | Fan | | | | | | A | B | A | B | | | | | |Failure|Failure|Failure|Failure| | | | | +-------+-------+-------+-------+-------+-------+-------+-------+
Status: current Access: read-write
OBJECT-TYPE    
  BITS sbs2GHzPowerHigh(0), sbs2GHzPowerLow(1), sbs6GHzPowerHigh(2), sbs6GHzPowerLow(3), system5VPowerHigh(4), system5VPowerLow(5), system12VPowerHigh(6), system12VPowerLow(7), system24VPowerHigh(8), system24VPowerLow(9), systemM5VPowerHigh(10), systemM5VPowerLow(11), systemM12VPowerHigh(12), systemM12VPowerLow(13), communicationFailure(14), powerSupplyAFailure(16), powerSupplyBFailure(17), coolingFanAFailure(18), coolingFanBFailure(19)  

miscStatusMajor 1.3.6.1.4.1.11606.7.1.40
Returns a bit mapped status word where each bit set (as defined below) indicates a specific active alarm: 0 1 2 3 4 5 6 7 +-------+-------+-------+-------+-------+-------+-------+-------+ | 2 GHz | 2 GHz | 6 GHz | 6 GHz |System |System |System |System | | SBS | SBS | SBS | SBS | +5V | +5V | +12V | +12V | | Power | Power | Power | Power | Power | Power | Power | Power | | High | Low | High | Low | High | Low | High | Low | +-------+-------+-------+-------+-------+-------+-------+-------+ 8 9 10 11 12 13 14 15 +-------+-------+-------+-------+-------+-------+-------+-------+ |System |System |System |System |System |System | Comm |Power | | +24V | +24V | -5V | -5V | -12V | -12V |Failure|Supply | | Power | Power | Power | Power | Power | Power | |Failure| | High | Low | High | Low | High | Low | | | +-------+-------+-------+-------+-------+-------+-------+-------+ 16 17 18 19 20 21 22 23 +-------+-------+-------+-------+-------+-------+-------+-------+ | Power | Power |Cooling|Cooling| | | | | | Supply| Supply| Fan | Fan | | | | | | A | B | A | B | | | | | |Failure|Failure|Failure|Failure| | | | | +-------+-------+-------+-------+-------+-------+-------+-------+
Status: current Access: read-only
OBJECT-TYPE    
  BITS sbs2GHzPowerHigh(0), sbs2GHzPowerLow(1), sbs6GHzPowerHigh(2), sbs6GHzPowerLow(3), system5VPowerHigh(4), system5VPowerLow(5), system12VPowerHigh(6), system12VPowerLow(7), system24VPowerHigh(8), system24VPowerLow(9), systemM5VPowerHigh(10), systemM5VPowerLow(11), systemM12VPowerHigh(12), systemM12VPowerLow(13), communicationFailure(14), powerSupplyAFailure(16), powerSupplyBFailure(17), coolingFanAFailure(18), coolingFanBFailure(19)  

miscStatusMinor 1.3.6.1.4.1.11606.7.1.41
Returns a bit mapped status word where each bit set (as defined below) indicates a specific active warning: 0 1 2 3 4 5 6 7 +-------+-------+-------+-------+-------+-------+-------+-------+ | 2 GHz | 2 GHz | 6 GHz | 6 GHz |System |System |System |System | | SBS | SBS | SBS | SBS | +5V | +5V | +12V | +12V | | Power | Power | Power | Power | Power | Power | Power | Power | | High | Low | High | Low | High | Low | High | Low | +-------+-------+-------+-------+-------+-------+-------+-------+ 8 9 10 11 12 13 14 15 +-------+-------+-------+-------+-------+-------+-------+-------+ |System |System |System |System |System |System | Comm |Power | | +24V | +24V | -5V | -5V | -12V | -12V |Failure|Supply | | Power | Power | Power | Power | Power | Power | |Failure| | High | Low | High | Low | High | Low | | | +-------+-------+-------+-------+-------+-------+-------+-------+ 16 17 18 19 20 21 22 23 +-------+-------+-------+-------+-------+-------+-------+-------+ | Power | Power |Cooling|Cooling| | | | | | Supply| Supply| Fan | Fan | | | | | | A | B | A | B | | | | | |Failure|Failure|Failure|Failure| | | | | +-------+-------+-------+-------+-------+-------+-------+-------+
Status: current Access: read-only
OBJECT-TYPE    
  BITS sbs2GHzPowerHigh(0), sbs2GHzPowerLow(1), sbs6GHzPowerHigh(2), sbs6GHzPowerLow(3), system5VPowerHigh(4), system5VPowerLow(5), system12VPowerHigh(6), system12VPowerLow(7), system24VPowerHigh(8), system24VPowerLow(9), systemM5VPowerHigh(10), systemM5VPowerLow(11), systemM12VPowerHigh(12), systemM12VPowerLow(13), communicationFailure(14), powerSupplyAFailure(16), powerSupplyBFailure(17), coolingFanAFailure(18), coolingFanBFailure(19)  

miscStatusHistory 1.3.6.1.4.1.11606.7.1.42
Returns a bit mapped status word where each bit set (as defined below) indicates a an alarm had occurred since the last power up or clear: 0 1 2 3 4 5 6 7 +-------+-------+-------+-------+-------+-------+-------+-------+ | 2 GHz | 2 GHz | 6 GHz | 6 GHz |System |System |System |System | | SBS | SBS | SBS | SBS | +5V | +5V | +12V | +12V | | Power | Power | Power | Power | Power | Power | Power | Power | | High | Low | High | Low | High | Low | High | Low | +-------+-------+-------+-------+-------+-------+-------+-------+ 8 9 10 11 12 13 14 15 +-------+-------+-------+-------+-------+-------+-------+-------+ |System |System |System |System |System |System | Comm |Power | | +24V | +24V | -5V | -5V | -12V | -12V |Failure|Supply | | Power | Power | Power | Power | Power | Power | |Failure| | High | Low | High | Low | High | Low | | | +-------+-------+-------+-------+-------+-------+-------+-------+ 16 17 18 19 20 21 22 23 +-------+-------+-------+-------+-------+-------+-------+-------+ | Power | Power |Cooling|Cooling| | | | | | Supply| Supply| Fan | Fan | | | | | | A | B | A | B | | | | | |Failure|Failure|Failure|Failure| | | | | +-------+-------+-------+-------+-------+-------+-------+-------+ Clear status history by writing a value of 0.
Status: current Access: read-write
OBJECT-TYPE    
  BITS sbs2GHzPowerHigh(0), sbs2GHzPowerLow(1), sbs6GHzPowerHigh(2), sbs6GHzPowerLow(3), system5VPowerHigh(4), system5VPowerLow(5), system12VPowerHigh(6), system12VPowerLow(7), system24VPowerHigh(8), system24VPowerLow(9), systemM5VPowerHigh(10), systemM5VPowerLow(11), systemM12VPowerHigh(12), systemM12VPowerLow(13), communicationFailure(14), powerSupplyAFailure(16), powerSupplyBFailure(17), coolingFanAFailure(18), coolingFanBFailure(19)  

frontPanelLEDStatus 1.3.6.1.4.1.11606.7.1.43
Returns a bit mapped status word where each bit set (as defined below) indicates a specific LED state: 0 1 2 3 4 5 +-------+-------+-------+-------+-------+-------+ | Laser | Laser |Status |Status |Status |LaserOn| | On | Off | Okay | Major | Minor | Rear | | | | | Alarm | Alarm | Panel | | Green | Red | Green | Red | Red | Green | +-------+-------+-------+-------+-------+-------+
Status: current Access: read-only
OBJECT-TYPE    
  BITS laserOn(0), laserOff(1), statusOkay(2), majorAlarmActive(3), minorAlarmActive(4), laserOnRearPanel(5)  

upTime 1.3.6.1.4.1.11606.7.1.44
Returns the number of elapsed seconds since the last time the unit restarted.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

transmitterNotificationPrefix 1.3.6.1.4.1.11606.7.1.45
OBJECT IDENTIFIER    

transmitterCommonNotifications 1.3.6.1.4.1.11606.7.1.45.0
OBJECT IDENTIFIER    

transmitterNoAlarmsPresent 1.3.6.1.4.1.11606.7.1.45.0.0
No alarms are present.
Status: current Access: read-only
NOTIFICATION-TYPE    

transmitterSystemTemperatureHigh 1.3.6.1.4.1.11606.7.1.45.0.1
The system temperature has exceeded its normal operating value.
Status: current Access: read-only
NOTIFICATION-TYPE    

transmitterSystemTemperatureLow 1.3.6.1.4.1.11606.7.1.45.0.2
The system temperature has exceeded its normal operating value.
Status: current Access: read-only
NOTIFICATION-TYPE    

transmitterLaserCurrentHigh 1.3.6.1.4.1.11606.7.1.45.0.3
The laser current has exceeded its normal operating value.
Status: current Access: read-only
NOTIFICATION-TYPE    

transmitterLaserCurrentLow 1.3.6.1.4.1.11606.7.1.45.0.4
The laser current has exceeded its normal operating value.
Status: current Access: read-only
NOTIFICATION-TYPE    

transmitterLaserTemperatureHigh 1.3.6.1.4.1.11606.7.1.45.0.5
The laser temperature has exceeded its normal operating value.
Status: current Access: read-only
NOTIFICATION-TYPE    

transmitterLaserTemperatureLow 1.3.6.1.4.1.11606.7.1.45.0.6
The laser temperature has exceeded its normal operating value.
Status: current Access: read-only
NOTIFICATION-TYPE    

transmitterInputRFLevelHigh 1.3.6.1.4.1.11606.7.1.45.0.7
The input RF level has exceeded its normal operating value.
Status: current Access: read-only
NOTIFICATION-TYPE    

transmitterInputRFLevelLow 1.3.6.1.4.1.11606.7.1.45.0.8
The input RF level has exceeded its normal operating value.
Status: current Access: read-only
NOTIFICATION-TYPE    

transmitterOpticalPowerOutputHigh 1.3.6.1.4.1.11606.7.1.45.0.9
The optical power output has exceeded its normal operating value.
Status: current Access: read-only
NOTIFICATION-TYPE    

transmitterOpticalPowerOutputLow 1.3.6.1.4.1.11606.7.1.45.0.10
The optical power output has exceeded its normal operating value.
Status: current Access: read-only
NOTIFICATION-TYPE    

transmitterTECCurrentHigh 1.3.6.1.4.1.11606.7.1.45.0.11
The thermoelectric cooler current has exceeded its normal operating value.
Status: current Access: read-only
NOTIFICATION-TYPE    

transmitterAGCUnlocked 1.3.6.1.4.1.11606.7.1.45.0.12
The RF attenuator automatic gain control (AGC) is outside its normal operating range.
Status: current Access: read-only
NOTIFICATION-TYPE    

transmitterKeySwitchOffPosition 1.3.6.1.4.1.11606.7.1.45.0.13
The key switch is in the OFF position.
Status: current Access: read-only
NOTIFICATION-TYPE    

transmitterRemoteLaserOffMode 1.3.6.1.4.1.11606.7.1.45.0.14
The remote laser control is commanded to be in OFF mode.
Status: current Access: read-only
NOTIFICATION-TYPE    

transmitter2GHzSBSPowerHigh 1.3.6.1.4.1.11606.7.1.45.0.15
The 2GHz SBS output power has exceeded its normal operating value.
Status: current Access: read-only
NOTIFICATION-TYPE    

transmitter2GHzSBSPowerLow 1.3.6.1.4.1.11606.7.1.45.0.16
The 2GHz SBS output power has exceeded its normal operating value.
Status: current Access: read-only
NOTIFICATION-TYPE    

transmitter6GHzSBSPowerHigh 1.3.6.1.4.1.11606.7.1.45.0.17
The 6GHz SBS output power has exceeded its normal operating value.
Status: current Access: read-only
NOTIFICATION-TYPE    

transmitter6GHzSBSPowerLow 1.3.6.1.4.1.11606.7.1.45.0.18
The 6GHz SBS output power has exceeded its normal operating value.
Status: current Access: read-only
NOTIFICATION-TYPE    

transmitterSystem5VPowerHigh 1.3.6.1.4.1.11606.7.1.45.0.19
The system +5V power supply has exceeded its normal operating value.
Status: current Access: read-only
NOTIFICATION-TYPE    

transmitterSystem5VPowerLow 1.3.6.1.4.1.11606.7.1.45.0.20
The system +5V power supply has exceeded its normal operating value.
Status: current Access: read-only
NOTIFICATION-TYPE    

transmitterSystem12VPowerHigh 1.3.6.1.4.1.11606.7.1.45.0.21
The system +12V power supply has exceeded its normal operating value.
Status: current Access: read-only
NOTIFICATION-TYPE    

transmitterSystem12VPowerLow 1.3.6.1.4.1.11606.7.1.45.0.22
The system +12V power supply has exceeded its normal operating value.
Status: current Access: read-only
NOTIFICATION-TYPE    

transmitterSystem24VPowerHigh 1.3.6.1.4.1.11606.7.1.45.0.23
The system +24V power supply has exceeded its normal operating value.
Status: current Access: read-only
NOTIFICATION-TYPE    

transmitterSystem24VPowerLow 1.3.6.1.4.1.11606.7.1.45.0.24
The system +24V power supply has exceeded its normal operating value.
Status: current Access: read-only
NOTIFICATION-TYPE    

transmitterSystemM5VPowerHigh 1.3.6.1.4.1.11606.7.1.45.0.25
The system -5V power supply has exceeded its normal operating value.
Status: current Access: read-only
NOTIFICATION-TYPE    

transmitterSystemM5VPowerLow 1.3.6.1.4.1.11606.7.1.45.0.26
The system -5V power supply has exceeded its normal operating value.
Status: current Access: read-only
NOTIFICATION-TYPE    

transmitterSystemM12VPowerHigh 1.3.6.1.4.1.11606.7.1.45.0.27
The system -12V power supply has exceeded its normal operating value.
Status: current Access: read-only
NOTIFICATION-TYPE    

transmitterSystemM12VPowerLow 1.3.6.1.4.1.11606.7.1.45.0.28
The system -12V power supply has exceeded its normal operating value.
Status: current Access: read-only
NOTIFICATION-TYPE    

transmitterCommunicationFailure 1.3.6.1.4.1.11606.7.1.45.0.29
A failure was detected with the internal network communication interface.
Status: current Access: read-only
NOTIFICATION-TYPE    

transmitterPowerSupplyAFailure 1.3.6.1.4.1.11606.7.1.45.0.30
A failure was detected with power supply module A.
Status: current Access: read-only
NOTIFICATION-TYPE    

transmitterPowerSupplyBFailure 1.3.6.1.4.1.11606.7.1.45.0.31
A failure was detected with power supply module B.
Status: current Access: read-only
NOTIFICATION-TYPE    

transmitterCoolingFanAFailure 1.3.6.1.4.1.11606.7.1.45.0.32
A failure was detected with cooling fan A.
Status: current Access: read-only
NOTIFICATION-TYPE    

transmitterCoolingFanBFailure 1.3.6.1.4.1.11606.7.1.45.0.33
A failure was detected with cooling fan B.
Status: current Access: read-only
NOTIFICATION-TYPE    

lte153PowerSupply 1.3.6.1.4.1.11606.7.2
OBJECT IDENTIFIER    

powerSupplyType 1.3.6.1.4.1.11606.7.2.1
Returns the installed power supply type. single5V(1) - Single AC/DC power supply with rated output of 5V at 100W. dualRedundant5V(2) - Dual, redundant AC/DC power supplies with rated output of 5V at 100W each. single5-12-24V(3) - Single AC/DC power supply with rated outputs of 5V, +/-12V and 24V at 100W total. dualRedundant5-12-24V(4) - Dual, redundant AC/DC power supplies with rated outputs of 5V, +/-12V and 24V at 100W total.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER undefined(0), single5V(1), dualRedundant5V(2), single5-12-24V(3), dualRedundant5-12-24V(4)  

powerSupplyTemp 1.3.6.1.4.1.11606.7.2.2
Returns the power supply regulator temperature.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -500..1200  

powerSupplyStatusA 1.3.6.1.4.1.11606.7.2.3
Returns the operating status of power supply A.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER undefined(0), nominal(1), failure(2), notInstalled(3)  

powerSupplyStatusB 1.3.6.1.4.1.11606.7.2.4
Returns the operating status of power supply B.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER undefined(0), nominal(1), failure(2), notInstalled(3)  

coolingFanA 1.3.6.1.4.1.11606.7.2.5
Returns the operating status of chassis cooling fan A.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER undefined(0), nominal(1), failure(2), notInstalled(3)  

coolingFanB 1.3.6.1.4.1.11606.7.2.6
Returns the operating status of chassis cooling fan B.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER undefined(0), nominal(1), failure(2), notInstalled(3)  

upTime 1.3.6.1.4.1.11606.7.2.7
Returns the number of elapsed seconds since the last time the unit restarted.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

powerSupplyNotificationPrefix 1.3.6.1.4.1.11606.7.2.8
OBJECT IDENTIFIER    

powerSupplyNotifications 1.3.6.1.4.1.11606.7.2.8.0
OBJECT IDENTIFIER    

powerSupplyNoAlarmsPresent 1.3.6.1.4.1.11606.7.2.8.0.0
No alarms are present.
Status: current Access: read-only
NOTIFICATION-TYPE    

powerSupplyPowerSupplyFailureA 1.3.6.1.4.1.11606.7.2.8.0.1
A failure was detected with power supply module A.
Status: current Access: read-only
NOTIFICATION-TYPE    

powerSupplyPowerSupplyFailureB 1.3.6.1.4.1.11606.7.2.8.0.2
A failure was detected with power supply module B.
Status: current Access: read-only
NOTIFICATION-TYPE    

powerSupplyCoolingFanFailureA 1.3.6.1.4.1.11606.7.2.8.0.3
A failure was detected with chassis cooling fan A.
Status: current Access: read-only
NOTIFICATION-TYPE    

powerSupplyCoolingFanFailureB 1.3.6.1.4.1.11606.7.2.8.0.4
A failure was detected with chassis cooling fan B.
Status: current Access: read-only
NOTIFICATION-TYPE    

module15 15
PBN Module 1 Param 5 Alarm notification
TRAP-TYPE    

module16 16
PBN Module 1 Param 6 Alarm notification
TRAP-TYPE    

module17 17
PBN Module 1 Param 7 Alarm notification
TRAP-TYPE    

module18 18
PBN Module 1 Param 8 Alarm notification
TRAP-TYPE    

module19 19
PBN Module 1 Param 9 notification
TRAP-TYPE    

module25 25
PBN Module 2 Param 5 notification
TRAP-TYPE    

module26 26
PBN Module 2 Param 6 notification
TRAP-TYPE    

module27 27
PBN Module 2 Param 7 notification
TRAP-TYPE    

module28 28
PBN Module 2 Param 8 notification
TRAP-TYPE    

module29 29
PBN Module 2 Param 9 notification
TRAP-TYPE    

module35 35
PBN Module 3 Param 5 notification
TRAP-TYPE    

module36 36
PBN Module 3 Param 6 notification
TRAP-TYPE    

module37 37
PBN Module 3 Param 7 notification
TRAP-TYPE    

module38 38
PBN Module 3 Param 8 notification
TRAP-TYPE    

module39 39
PBN Module 3 Param 9 notification
TRAP-TYPE    

module45 45
PBN Module 4 Param 5 notification
TRAP-TYPE    

module46 46
PBN Module 4 Param 6 notification
TRAP-TYPE    

module47 47
PBN Module 4 Param 7 notification
TRAP-TYPE    

module48 48
PBN Module 4 Param 8 notification
TRAP-TYPE    

module49 49
PBN Module 4 Param 9 notification
TRAP-TYPE    

module110 110
PBN Module 1 Param 10 notification
TRAP-TYPE    

module111 111
PBN Module 1 Param 11 notification
TRAP-TYPE    

module112 112
PBN Module 1 Param 12 notification
TRAP-TYPE    

module113 113
PBN Module 1 Param 13 notification
TRAP-TYPE    

module114 114
PBN Module 1 Param 14 notification
TRAP-TYPE    

module115 115
PBN Module 1 Param 15 notification
TRAP-TYPE    

module116 116
PBN Module 1 Param 16 notification
TRAP-TYPE    

module117 117
PBN Module 1 Param 17 notification
TRAP-TYPE    

module118 118
PBN Module 1 Param 18 notification
TRAP-TYPE    

module119 119
PBN Module 1 Param 19 notification
TRAP-TYPE    

module120 120
PBN Module 1 Param 20 notification
TRAP-TYPE    

module121 121
PBN Module 1 Param 21 notification
TRAP-TYPE    

module122 122
PBN Module 1 Param 22 notification
TRAP-TYPE    

module123 123
PBN Module 1 Param 23 notification
TRAP-TYPE    

module124 124
PBN Module 1 Param 24 notification
TRAP-TYPE    

module125 125
PBN Module 1 Param 25 notification
TRAP-TYPE    

module126 126
PBN Module 1 Param 26 notification
TRAP-TYPE    

module127 127
PBN Module 1 Param 27 notification
TRAP-TYPE    

module128 128
PBN Module 1 Param 28 notification
TRAP-TYPE    

module129 129
PBN Module 1 Param 29 notification
TRAP-TYPE    

module130 130
PBN Module 1 Param 30 notification
TRAP-TYPE    

module131 131
PBN Module 1 Param 31 notification
TRAP-TYPE    

module210 210
PBN Module 2 Param 10 notification
TRAP-TYPE    

module211 211
PBN Module 2 Param 11 notification
TRAP-TYPE    

module212 212
PBN Module 2 Param 12 notification
TRAP-TYPE    

module213 213
PBN Module 2 Param 13 notification
TRAP-TYPE    

module214 214
PBN Module 2 Param 14 notification
TRAP-TYPE    

module215 215
PBN Module 2 Param 15 notification
TRAP-TYPE    

module216 216
PBN Module 2 Param 16 notification
TRAP-TYPE    

module217 217
PBN Module 2 Param 17 notification
TRAP-TYPE    

module218 218
PBN Module 2 Param 18 notification
TRAP-TYPE    

module219 219
PBN Module 2 Param 19 Alarm notification
TRAP-TYPE    

module220 220
PBN Module 2 Param 20 notification
TRAP-TYPE    

module221 221
PBN Module 2 Param 21 notification
TRAP-TYPE    

module222 222
PBN Module 2 Param 22 notification
TRAP-TYPE    

module223 223
PBN Module 2 Param 23 notification
TRAP-TYPE    

module224 224
PBN Module 2 Param 24 notification
TRAP-TYPE    

module225 225
PBN Module 2 Param 25 notification
TRAP-TYPE    

module226 226
PBN Module 2 Param 26 notification
TRAP-TYPE    

module227 227
PBN Module 2 Param 27 notification
TRAP-TYPE    

module228 228
PBN Module 2 Param 28 notification
TRAP-TYPE    

module229 229
PBN Module 2 Param 29 notification
TRAP-TYPE    

module230 230
PBN Module 2 Param 30 notification
TRAP-TYPE    

module231 231
PBN Module 2 Param 31 notification
TRAP-TYPE    

module310 310
PBN Module 3 Param 10 notification
TRAP-TYPE    

module311 311
PBN Module 3 Param 11 notification
TRAP-TYPE    

module312 312
PBN Module 3 Param 12 notification
TRAP-TYPE    

module313 313
PBN Module 3 Param 13 notification
TRAP-TYPE    

module314 314
PBN Module 3 Param 14 notification
TRAP-TYPE    

module315 315
PBN Module 3 Param 15 notification
TRAP-TYPE    

module316 316
PBN Module 3 Param 16 notification
TRAP-TYPE    

module317 317
PBN Module 3 Param 17 notification
TRAP-TYPE    

module318 318
PBN Module 3 Param 18 notification
TRAP-TYPE    

module319 319
PBN Module 3 Param 19 notification
TRAP-TYPE    

module320 320
PBN Module 3 Param 20 notification
TRAP-TYPE    

module321 321
PBN Module 3 Param 21 notification
TRAP-TYPE    

module322 322
PBN Module 3 Param 22 notification
TRAP-TYPE    

module323 323
PBN Module 3 Param 23 notification
TRAP-TYPE    

module324 324
PBN Module 3 Param 24 notification
TRAP-TYPE    

module325 325
PBN Module 3 Param 25 notification
TRAP-TYPE    

module326 326
PBN Module 3 Param 26 notification
TRAP-TYPE    

module327 327
PBN Module 3 Param 27 notification
TRAP-TYPE    

module328 328
PBN Module 3 Param 28 notification
TRAP-TYPE    

module329 329
PBN Module 3 Param 29 notification
TRAP-TYPE    

module330 330
PBN Module 3 Param 30 notification
TRAP-TYPE    

module331 331
PBN Module 3 Param 31 notification
TRAP-TYPE    

module410 410
PBN Module 4 Param 10 notification
TRAP-TYPE    

module411 411
PBN Module 4 Param 11 notification
TRAP-TYPE    

cpon100ContactInput 412
CPON-100 Tamper alarm
TRAP-TYPE    

cpon100sensingInput 413
CPON-100 Battery alarm
TRAP-TYPE    

cpon100CATVAlarm 414
CPON-100 CATV alarm
TRAP-TYPE    

mauStatus5VTrap 415
TRAP-TYPE    

mauStatus12VTrap 416
TRAP-TYPE    

mauStatus24VTrap 417
TRAP-TYPE    

mauStatusInputOpticalPowerTrap 418
TRAP-TYPE    

mauStatusOutputOpticalPowerTrap 419
TRAP-TYPE    

mauStatusRFOutputTrap 420
TRAP-TYPE    

mauStatusTemperatureTrap 421
TRAP-TYPE    

mauStatusLidTrap 422
TRAP-TYPE