OPTIX-SONET-TU-MIB-V2

File: OPTIX-SONET-TU-MIB-V2.mib (19231 bytes)

Imported modules

OPTIX-OID-MIB SNMPv2-CONF SNMPv2-SMI
SNMPv2-TC

Imported symbols

optixProvisionSonet OBJECT-GROUP MODULE-COMPLIANCE
Gauge32 OBJECT-TYPE MODULE-IDENTITY
TEXTUAL-CONVENTION

Defined Types

LpbkType  
Enter the description for the LpbkType TEXTUAL-CONVENTION converted from type assignment.
TEXTUAL-CONVENTION    
  INTEGER terminal(1), facility(2), crs(3), ds1feac(4), ds3feac(5), fac2ni(6), noloop(255)  

IntfType  
Enter the description for the IntfType TEXTUAL-CONVENTION converted from type assignment.
TEXTUAL-CONVENTION    
  INTEGER ds1-asyn-vt1(1), ds3-asyn-sts1(10), ec(12), ds3-tmux-ds1(13), ds3-srv-ds1(17), uas(65), mix(100), invalid(254)  

Ds3PortAttribEntry  
SEQUENCE    
  ds3PortIndexSlotId Gauge32
  ds3PortIndexPortId Gauge32
  ds3PortAttribReq INTEGER
  ds3PortAttribLbo INTEGER
  ds3PortAttribLineCde INTEGER
  ds3PortAttribFmt INTEGER
  ds3PortAttribTACC INTEGER
  ds3PortAttribLof2ais INTEGER
  ds3PortAttribSvtimer OCTET STRING
  ds3PortAttribPST OCTET STRING
  ds3PortAttribSST OCTET STRING
  ds3LoopbackStatus LpbkType
  ds3LoopbackTimeout Gauge32
  ds3RemoteALWFELPBK INTEGER

Ds1PortAttribEntry  
SEQUENCE    
  ds1PortIndexSlotId Gauge32
  ds1PortIndexPortId Gauge32
  ds1PortIndexPath Gauge32
  ds1PortAttribLbo INTEGER
  ds1PortAttribLineCde INTEGER
  ds1PortAttribFmt INTEGER
  ds1PortAttribTACC INTEGER
  ds1PortAttribLof2ais INTEGER
  ds1PortAttribSvtimer OCTET STRING
  ds1PortAttribPST OCTET STRING
  ds1PortAttribSST OCTET STRING
  ds1LoopbackStatus LpbkType
  ds1LoopbackTimeout Gauge32
  ds1RemoteALWFELPBK INTEGER
  ds1PortLpbkAutomaticTime Gauge32

PortTypeEntry  
SEQUENCE    
  portIndexSlotId Gauge32
  portIndexPortId Gauge32
  portType IntfType

Defined Values

optixsonetFacilityMgt 1.3.6.1.4.1.2011.2.25.4.20.2
Enter the description for this MIB module.
MODULE-IDENTITY    

ds3PortAttribTable 1.3.6.1.4.1.2011.2.25.4.20.2.1
The DS3 facilities configuration Table
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ds3PortAttribEntry

ds3PortAttribEntry 1.3.6.1.4.1.2011.2.25.4.20.2.1.1
The DS3 facilities configuration entry
Status: current Access: not-accessible
OBJECT-TYPE    
  Ds3PortAttribEntry  

ds3PortIndexSlotId 1.3.6.1.4.1.2011.2.25.4.20.2.1.1.1
Slot number. This will indicate what is the slot of the object.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ds3PortIndexPortId 1.3.6.1.4.1.2011.2.25.4.20.2.1.1.2
Port Number. This will indicate what is the Port of the object.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ds3PortAttribReq 1.3.6.1.4.1.2011.2.25.4.20.2.1.1.3
High or low receive equalizer.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER high(1), low(2), invalid(254)  

ds3PortAttribLbo 1.3.6.1.4.1.2011.2.25.4.20.2.1.1.4
Line build out. Line build out (DS3 port) values Value Description 1 Cable length range from 0 to 225 feet. 2 Cable length range from 226 to 450 feet.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..2  

ds3PortAttribLineCde 1.3.6.1.4.1.2011.2.25.4.20.2.1.1.5
DS3 line code. Valid value is B3ZS.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER b3zs(3), invalid(254)  

ds3PortAttribFmt 1.3.6.1.4.1.2011.2.25.4.20.2.1.1.6
Frame format. Valid values are CBIT, M23 or UNFRAMED. For PDM3 unit, if the port type is DS3_ASYN_STS1, then can be CBIT, M23 or UNFRAMED. If the port type is DS3_TMUX_DS1 or DS3_SRV_DS1, then the only can be CBIT or M23.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER cbit(3), m23(4), unframed(255)  

ds3PortAttribTACC 1.3.6.1.4.1.2011.2.25.4.20.2.1.1.7
Defines the DS3 port as a test access port with a selected unique TAP number.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..999  

ds3PortAttribLof2ais 1.3.6.1.4.1.2011.2.25.4.20.2.1.1.8
The parameter is provisioned to determine whether or not to generate DS3 AIS for the DS3 LOF. The Valid value of this parameter is 'no' and 'yes'. PQT3/PQT3A/PQT3P/PQT3B units support this parameter.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2), invalid(254)  

ds3PortAttribSvtimer 1.3.6.1.4.1.2011.2.25.4.20.2.1.1.9
Signal validation timer in minutes. Valid values are shown below. Value Description From 00-03 Signal validation timer in minutes. Only valid if auto in-service feature is supported. is a string, and format is: HH-MM. to 48-00 HH - Hour, it is an integer ranging from 0 to 48; MM - Minute, it is an integer ranging from 0 to 59. The longest time is 48 hours. Default is 00-03 (3 minutes).
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..6)  

ds3PortAttribPST 1.3.6.1.4.1.2011.2.25.4.20.2.1.1.10
The primary state of the entity. Administrative State (PST) Definition IS Puts the entity in service. OOS Puts the entity out of service.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..16)  

ds3PortAttribSST 1.3.6.1.4.1.2011.2.25.4.20.2.1.1.11
The secondary state of the entity. Administrative State (PST) Definition. AINS Puts the entity in automatic in-service. MT Removes the entity from service for maintenance.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..32)  

ds3LoopbackStatus 1.3.6.1.4.1.2011.2.25.4.20.2.1.1.12
This variable represents the current state of the loopback on the DS3 interface. It contains information about loopbacks established by a manager and remotely from the far end.
Status: current Access: read-write
OBJECT-TYPE    
  LpbkType  

ds3LoopbackTimeout 1.3.6.1.4.1.2011.2.25.4.20.2.1.1.13
The remnant time that loop-back will be released.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ds3RemoteALWFELPBK 1.3.6.1.4.1.2011.2.25.4.20.2.1.1.14
(Optional) Far-end loopback allowance attribute of the port. If it is enable, the automatic far-end loopbacks are allowed. It is either enable or disable. The system default is enable. The parameter type is ENABLE_DISABLE, which disables or enables an attribute.Automatic application of loopbacks originating from the far end can be initiated on the T3 ports of a PDM3 card.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2), invalid(254)  

ds1PortAttribTable 1.3.6.1.4.1.2011.2.25.4.20.2.2
The DS1 facilities configuration Table
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ds1PortAttribEntry

ds1PortAttribEntry 1.3.6.1.4.1.2011.2.25.4.20.2.2.1
The DS1 facilities configuration entry
Status: current Access: not-accessible
OBJECT-TYPE    
  Ds1PortAttribEntry  

ds1PortIndexSlotId 1.3.6.1.4.1.2011.2.25.4.20.2.2.1.1
Slot number. This will indicate what is the slot of the object.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ds1PortIndexPortId 1.3.6.1.4.1.2011.2.25.4.20.2.2.1.2
Port Number. This will indicate what is the Port of the object.For the Transmux unit this is the DS3 port number.And for other Ds1 units, it's the Ds1 port Number.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ds1PortIndexPath 1.3.6.1.4.1.2011.2.25.4.20.2.2.1.3
Ds1 identifier of the Transmux unit .For DS1 in a Transmux unit, it is equivalent to DS1 port number of its Transmux unit. For other Ds1 units, It will be zero.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ds1PortAttribLbo 1.3.6.1.4.1.2011.2.25.4.20.2.2.1.4
Line build out. Line build out (DS1 port) values Value Description 1 Cable length range from 0 to 131 feet. 2 Cable length range from 132 to 262 feet. 3 Cable length range from 263 to 393 feet. 4 Cable length range from 394 to 524 feet. 5 Cable length range from 525 to 655 feet.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..5  

ds1PortAttribLineCde 1.3.6.1.4.1.2011.2.25.4.20.2.2.1.5
DS1 Line coding. Valid value is AMI or B8ZS. Default is B8ZS.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER b8zs(1), ami(2), invalid(254)  

ds1PortAttribFmt 1.3.6.1.4.1.2011.2.25.4.20.2.2.1.6
Frame format. Valid value is SF, ESF or UNFRAMED.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER sf(1), esf(2), unframed(255)  

ds1PortAttribTACC 1.3.6.1.4.1.2011.2.25.4.20.2.2.1.7
Defines the DS1/T1 port as a test access port with a selected unique TAP number.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..999  

ds1PortAttribLof2ais 1.3.6.1.4.1.2011.2.25.4.20.2.2.1.8
The parameter is provisioned to determine whether or not to generate DS1 AIS for the DS1 LOF
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2), invalid(254)  

ds1PortAttribSvtimer 1.3.6.1.4.1.2011.2.25.4.20.2.2.1.9
Signal validation timer in minutes. Valid values are shown below. Value Description From 00-03 Signal validation timer in minutes. Only valid if auto in-service feature is supported. is a string, and format is: HH-MM. to 48-00 HH - Hour, it is an integer ranging from 0 to 48; MM - Minute, it is an integer ranging from 0 to 59. The longest time is 48 hours. Default is 00-03 (3 minutes).
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..6)  

ds1PortAttribPST 1.3.6.1.4.1.2011.2.25.4.20.2.2.1.10
The primary state of the entity. Administrative State (PST) Definition IS Puts the entity in service. OOS Puts the entity out of service.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..16)  

ds1PortAttribSST 1.3.6.1.4.1.2011.2.25.4.20.2.2.1.11
The secondary state of the entity. Administrative State (PST) Definition. AINS Puts the entity in automatic in-service. MT Removes the entity from service for maintenance.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..32)  

ds1LoopbackStatus 1.3.6.1.4.1.2011.2.25.4.20.2.2.1.12
This variable represents the current state of the loopback on the DS1 interface. It contains information about loopbacks established by a manager and remotely from the far end.
Status: current Access: read-write
OBJECT-TYPE    
  LpbkType  

ds1LoopbackTimeout 1.3.6.1.4.1.2011.2.25.4.20.2.2.1.13
The remnant time that loop-back will be released.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ds1RemoteALWFELPBK 1.3.6.1.4.1.2011.2.25.4.20.2.2.1.14
(Optional) Far-end loopback allowance attribute of the port. If it is enable, the automatic far-end loopbacks are allowed. It is either enable or disable. The system default is enable. The parameter type is ENABLE_DISABLE, which disables or enables an attribute.Automatic application of loopbacks originating from the far end can be initiated on the T1 ports of a PLT1,PDT1,PDT1P card.It indicates that the port not support this parameter when the attribute is invalid.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2), invalid(254)  

ds1PortLpbkAutomaticTime 1.3.6.1.4.1.2011.2.25.4.20.2.2.1.15
Time-out ticks (1 minute). For the T1 port default value is 120 (2 hours). 0 means time-out function is disabling. Valid values are 0~9999.
Status: current Access: read-write
OBJECT-TYPE    
  Gauge32  

portTypeTable 1.3.6.1.4.1.2011.2.25.4.20.2.3
Port type management table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PortTypeEntry

portTypeEntry 1.3.6.1.4.1.2011.2.25.4.20.2.3.1
Port type management entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  PortTypeEntry  

portIndexSlotId 1.3.6.1.4.1.2011.2.25.4.20.2.3.1.1
Slot number. This will indicate what is the slot of the object.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

portIndexPortId 1.3.6.1.4.1.2011.2.25.4.20.2.3.1.2
Port Number. This will indicate what is the Port of the object.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

portType 1.3.6.1.4.1.2011.2.25.4.20.2.3.1.3
The AID unit port type.Valid values are shown below. INTFTYPE values Value Description DS3_ASYN_STS1 DS3 signal asynchronous mapped into STS1. Default for DS3 unit. DS3_TMUX_DS1 Multiplexing and de-multiplexing of DS1s to/from DS3. Default for Transmux unit (PDM3). DS1_ASYN_VT1 DS1 signal asynchronous mapped into VT1. Default for DS1 unit. DS3_SRV_DS1 Multiplexing and de-multiplexing of DS1s to/from DS3 as M13 server. EC1 EC1 signal mapped into STS1. PQT3A support EC1 service. UAS It indicates there is no use of the port.
Status: current Access: read-write
OBJECT-TYPE    
  IntfType  

optixsonetFacilityMgtConformance 1.3.6.1.4.1.2011.2.25.4.20.2.4
OBJECT IDENTIFIER    

optixsonetFacilityMgtGroups 1.3.6.1.4.1.2011.2.25.4.20.2.4.1
OBJECT IDENTIFIER    

currentObjectGroup 1.3.6.1.4.1.2011.2.25.4.20.2.4.1.1
Enter the description of the created OBJECT-GROUP.
Status: current Access: read-write
OBJECT-GROUP    

optixsonetFacilityMgtCompliances 1.3.6.1.4.1.2011.2.25.4.20.2.4.2
OBJECT IDENTIFIER    

basicCompliance 1.3.6.1.4.1.2011.2.25.4.20.2.4.2.1
Enter the description of the created MODULE-COMPLIANCE.
Status: current Access: read-write
MODULE-COMPLIANCE