OPTIX-SONET-PER-MIB

File: OPTIX-SONET-PER-MIB.mib (25357 bytes)

Imported modules

OPTIX-OID-MIB OPTIX-SONET-TC-MIB SNMPv2-CONF
SNMPv2-SMI SNMPv2-TC

Imported symbols

optixCommonSonet MOD2Type PerformanceEventType
LocationType DirectionType ValidflagType
OBJECT-GROUP MODULE-COMPLIANCE Integer32
Unsigned32 OBJECT-TYPE MODULE-IDENTITY
DateAndTime

Defined Types

Per15mCurDataEntry  
SEQUENCE    
  pm15mCurDataMOD2 MOD2Type
  pm15mCurDataSlot Unsigned32
  pm15mCurDataPort Unsigned32
  pm15mCurDataPath Unsigned32
  pm15mCurDataVT Unsigned32
  pm15mCurDataName PerformanceEventType
  pm15mCurDataLocation LocationType
  pm15mCurDataDirection DirectionType
  pm15mCurDataMonVal Integer32
  pm15mCurDataVldty ValidflagType
  pm15mCurDataStartTime DateAndTime

Per15mHisDataEntry  
SEQUENCE    
  pm15mHisDataMOD2 MOD2Type
  pm15mHisDataSlot Unsigned32
  pm15mHisDataPort Unsigned32
  pm15mHisDataPath Unsigned32
  pm15mHisDataVT Unsigned32
  pm15mHisDataName PerformanceEventType
  pm15mHisDataLocation LocationType
  pm15mHisDataDirection DirectionType
  pm15mHisDataInterval Unsigned32
  pm15mHisDataMonVal Integer32
  pm15mHisDataVldty ValidflagType
  pm15mHisDataStartTime DateAndTime

Per1dayCurDataEntry  
SEQUENCE    
  pm1dayCurDataMOD2 MOD2Type
  pm1dayCurDataSlot Unsigned32
  pm1dayCurDataPort Unsigned32
  pm1dayCurDataPath Unsigned32
  pm1dayCurDataVT Unsigned32
  pm1dayCurDataName PerformanceEventType
  pm1dayCurDataLocation LocationType
  pm1dayCurDataDirection DirectionType
  pm1dayCurDataMonVal Integer32
  pm1dayCurDataVldty ValidflagType
  pm1dayCurDataStartTime DateAndTime

Per1dayHisDataEntry  
SEQUENCE    
  pm1dayHisDataMOD2 MOD2Type
  pm1dayHisDataSlot Unsigned32
  pm1dayHisDataPort Unsigned32
  pm1dayHisDataPath Unsigned32
  pm1dayHisDataVT Unsigned32
  pm1dayHisDataName PerformanceEventType
  pm1dayHisDataLocation LocationType
  pm1dayHisDataDirection DirectionType
  pm1dayHisDataInterval Unsigned32
  pm1dayHisDataMonVal Integer32
  pm1dayHisDataVldty ValidflagType
  pm1dayHisDataStartTime DateAndTime

Defined Values

optixSonetPerformance 1.3.6.1.4.1.2011.2.25.3.20.20
Description.
MODULE-IDENTITY    

pmData 1.3.6.1.4.1.2011.2.25.3.20.20.10
OBJECT IDENTIFIER    

per15mCurDataTable 1.3.6.1.4.1.2011.2.25.3.20.20.10.10
instructs an NE to send its current set of PM data associated with one or more equipment units, facilities, links, or signaling links within the NE.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Per15mCurDataEntry

per15mCurDataEntry 1.3.6.1.4.1.2011.2.25.3.20.20.10.10.1
instructs an NE to send its current set of PM data associated with one or more equipment units, facilities, links, or signaling links within the NE.
Status: current Access: not-accessible
OBJECT-TYPE    
  Per15mCurDataEntry  

pm15mCurDataMOD2 1.3.6.1.4.1.2011.2.25.3.20.20.10.10.1.1
Signal mode.
Status: current Access: read-only
OBJECT-TYPE    
  MOD2Type  

pm15mCurDataSlot 1.3.6.1.4.1.2011.2.25.3.20.20.10.10.1.2
Slot number. This will indicate what is the slot of the object which raised this PM data. If not relevant to the PM data, will be zero.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

pm15mCurDataPort 1.3.6.1.4.1.2011.2.25.3.20.20.10.10.1.3
Port number. This will indicate what is the Port of the object which raised this PM data. If not relevant to the PM data, will be zero.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

pm15mCurDataPath 1.3.6.1.4.1.2011.2.25.3.20.20.10.10.1.4
Path number. This will indicate what is the Path of the object which raised this PM data. If not relevant to the PM data, will be zero.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

pm15mCurDataVT 1.3.6.1.4.1.2011.2.25.3.20.20.10.10.1.5
VT path number. This will indicate what is the VT path of the object which raised this PM data. If not relevant to the PM data, will be zero.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

pm15mCurDataName 1.3.6.1.4.1.2011.2.25.3.20.20.10.10.1.6
Indicates the type of monitored parameter for which a value is retrieved.
Status: current Access: read-only
OBJECT-TYPE    
  PerformanceEventType  

pm15mCurDataLocation 1.3.6.1.4.1.2011.2.25.3.20.20.10.10.1.7
Indicates the location. Only NEND(Near end)|FEND(Far end)|ALL will be represented here.
Status: current Access: read-only
OBJECT-TYPE    
  LocationType  

pm15mCurDataDirection 1.3.6.1.4.1.2011.2.25.3.20.20.10.10.1.8
specifies the direction of monitoring. Only RCV(Receive direction)|TRMT(Transmit direction)|ALL will be represented here.
Status: current Access: read-only
OBJECT-TYPE    
  DirectionType  

pm15mCurDataMonVal 1.3.6.1.4.1.2011.2.25.3.20.20.10.10.1.9
Measured value.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

pm15mCurDataVldty 1.3.6.1.4.1.2011.2.25.3.20.20.10.10.1.10
It indicates whether the information for the specified time period was accumulated over the entire time period or some portion of it. Only INVALID|VALID will be represented here.
Status: current Access: read-only
OBJECT-TYPE    
  ValidflagType  

pm15mCurDataStartTime 1.3.6.1.4.1.2011.2.25.3.20.20.10.10.1.11
The beginning date and time of the PM period.
Status: current Access: read-only
OBJECT-TYPE    
  DateAndTime  

per15mHisDataTable 1.3.6.1.4.1.2011.2.25.3.20.20.10.20
instructs an NE to send its history set of PM data associated with one or more equipment units, facilities, links, or signaling links within the NE.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Per15mHisDataEntry

per15mHisDataEntry 1.3.6.1.4.1.2011.2.25.3.20.20.10.20.1
instructs an NE to send its history set of PM data associated with one or more equipment units, facilities, links, or signaling links within the NE.
Status: current Access: not-accessible
OBJECT-TYPE    
  Per15mHisDataEntry  

pm15mHisDataMOD2 1.3.6.1.4.1.2011.2.25.3.20.20.10.20.1.1
Signal mode.
Status: current Access: read-only
OBJECT-TYPE    
  MOD2Type  

pm15mHisDataSlot 1.3.6.1.4.1.2011.2.25.3.20.20.10.20.1.2
Slot number. This will indicate what is the slot of the object which raised this PM data. If not relevant to the PM data, will be zero.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

pm15mHisDataPort 1.3.6.1.4.1.2011.2.25.3.20.20.10.20.1.3
Port number. This will indicate what is the Port of the object which raised this PM data. If not relevant to the PM data, will be zero.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

pm15mHisDataPath 1.3.6.1.4.1.2011.2.25.3.20.20.10.20.1.4
Path number. This will indicate what is the Path of the object which raised this PM data. If not relevant to the PM data, will be zero.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

pm15mHisDataVT 1.3.6.1.4.1.2011.2.25.3.20.20.10.20.1.5
VT path number. This will indicate what is the VT path of the object which raised this PM data. If not relevant to the PM data, will be zero.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

pm15mHisDataName 1.3.6.1.4.1.2011.2.25.3.20.20.10.20.1.6
Indicates the type of monitored parameter for which a value is retrieved.
Status: current Access: read-only
OBJECT-TYPE    
  PerformanceEventType  

pm15mHisDataLocation 1.3.6.1.4.1.2011.2.25.3.20.20.10.20.1.7
Indicates the location. Only NEND(Near end)|FEND(Far end)|ALL will be represented here.
Status: current Access: read-only
OBJECT-TYPE    
  LocationType  

pm15mHisDataDirection 1.3.6.1.4.1.2011.2.25.3.20.20.10.20.1.8
Specifies the direction of monitoring. Only RCV(Receive direction)|TRMT(Transmit direction)|ALL will be represented here.
Status: current Access: read-only
OBJECT-TYPE    
  DirectionType  

pm15mHisDataInterval 1.3.6.1.4.1.2011.2.25.3.20.20.10.20.1.9
The period number.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

pm15mHisDataMonVal 1.3.6.1.4.1.2011.2.25.3.20.20.10.20.1.10
Measured value.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

pm15mHisDataVldty 1.3.6.1.4.1.2011.2.25.3.20.20.10.20.1.11
It indicates whether the information for the specified time period was accumulated over the entire time period or some portion of it. Only INVALID|VALID will be represented here.
Status: current Access: read-only
OBJECT-TYPE    
  ValidflagType  

pm15mHisDataStartTime 1.3.6.1.4.1.2011.2.25.3.20.20.10.20.1.12
The beginning date and time of the PM period.
Status: current Access: read-only
OBJECT-TYPE    
  DateAndTime  

per1dayCurDataTable 1.3.6.1.4.1.2011.2.25.3.20.20.10.30
instructs an NE to send its current set of PM data associated with one or more equipment units, facilities, links, or signaling links within the NE.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Per1dayCurDataEntry

per1dayCurDataEntry 1.3.6.1.4.1.2011.2.25.3.20.20.10.30.1
instructs an NE to send its current set of PM data associated with one or more equipment units, facilities, links, or signaling links within the NE.
Status: current Access: not-accessible
OBJECT-TYPE    
  Per1dayCurDataEntry  

pm1dayCurDataMOD2 1.3.6.1.4.1.2011.2.25.3.20.20.10.30.1.1
Signal mode.
Status: current Access: read-only
OBJECT-TYPE    
  MOD2Type  

pm1dayCurDataSlot 1.3.6.1.4.1.2011.2.25.3.20.20.10.30.1.2
Slot number. This will indicate what is the slot of the object which raised this PM data. If not relevant to the PM data, will be zero.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

pm1dayCurDataPort 1.3.6.1.4.1.2011.2.25.3.20.20.10.30.1.3
Port number. This will indicate what is the Port of the object which raised this PM data. If not relevant to the PM data, will be zero.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

pm1dayCurDataPath 1.3.6.1.4.1.2011.2.25.3.20.20.10.30.1.4
Path number. This will indicate what is the Path of the object which raised this PM data. If not relevant to the PM data, will be zero.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

pm1dayCurDataVT 1.3.6.1.4.1.2011.2.25.3.20.20.10.30.1.5
VT path number. This will indicate what is the VT path of the object which raised this PM data. If not relevant to the PM data, will be zero.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

pm1dayCurDataName 1.3.6.1.4.1.2011.2.25.3.20.20.10.30.1.6
Indicates the type of monitored parameter for which a value is retrieved.
Status: current Access: read-only
OBJECT-TYPE    
  PerformanceEventType  

pm1dayCurDataLocation 1.3.6.1.4.1.2011.2.25.3.20.20.10.30.1.7
Indicates the location. Only NEND(Near end)|FEND(Far end)|ALL will be represented here.
Status: current Access: read-only
OBJECT-TYPE    
  LocationType  

pm1dayCurDataDirection 1.3.6.1.4.1.2011.2.25.3.20.20.10.30.1.8
Specifies the direction of monitoring. Only RCV(Receive direction)|TRMT(Transmit direction)|ALL will be represented here.
Status: current Access: read-only
OBJECT-TYPE    
  DirectionType  

pm1dayCurDataMonVal 1.3.6.1.4.1.2011.2.25.3.20.20.10.30.1.9
measured value.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

pm1dayCurDataVldty 1.3.6.1.4.1.2011.2.25.3.20.20.10.30.1.10
It indicates whether the information for the specified time period was accumulated over the entire time period or some portion of it. Only INVALID|VALID will be represented here.
Status: current Access: read-only
OBJECT-TYPE    
  ValidflagType  

pm1dayCurDataStartTime 1.3.6.1.4.1.2011.2.25.3.20.20.10.30.1.11
The beginning date and time of the PM period.
Status: current Access: read-only
OBJECT-TYPE    
  DateAndTime  

per1dayHisDataTable 1.3.6.1.4.1.2011.2.25.3.20.20.10.40
instructs an NE to send its history set of PM data associated with one or more equipment units, facilities, links, or signaling links within the NE.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Per1dayHisDataEntry

per1dayHisDataEntry 1.3.6.1.4.1.2011.2.25.3.20.20.10.40.1
instructs an NE to send its history set of PM data associated with one or more equipment units, facilities, links, or signaling links within the NE.
Status: current Access: not-accessible
OBJECT-TYPE    
  Per1dayHisDataEntry  

pm1dayHisDataMOD2 1.3.6.1.4.1.2011.2.25.3.20.20.10.40.1.1
Signal mode.
Status: current Access: read-only
OBJECT-TYPE    
  MOD2Type  

pm1dayHisDataSlot 1.3.6.1.4.1.2011.2.25.3.20.20.10.40.1.2
Slot number. This will indicate what is the slot of the object which raised this PM data. If not relevant to the PM data, will be zero.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

pm1dayHisDataPort 1.3.6.1.4.1.2011.2.25.3.20.20.10.40.1.3
Port number. This will indicate what is the Port of the object which raised this PM data. If not relevant to the PM data, will be zero.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

pm1dayHisDataPath 1.3.6.1.4.1.2011.2.25.3.20.20.10.40.1.4
Path number. This will indicate what is the Path of the object which raised this PM data. If not relevant to the PM data, will be zero.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

pm1dayHisDataVT 1.3.6.1.4.1.2011.2.25.3.20.20.10.40.1.5
VT path number. This will indicate what is the VT path of the object which raised this PM data. If not relevant to the PM data, will be zero.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

pm1dayHisDataName 1.3.6.1.4.1.2011.2.25.3.20.20.10.40.1.6
Indicates the type of monitored parameter for which a value is retrieved.
Status: current Access: read-only
OBJECT-TYPE    
  PerformanceEventType  

pm1dayHisDataLocation 1.3.6.1.4.1.2011.2.25.3.20.20.10.40.1.7
Indicates the location. Only NEND(Near end)|FEND(Far end)|ALL will be represented here.
Status: current Access: read-only
OBJECT-TYPE    
  LocationType  

pm1dayHisDataDirection 1.3.6.1.4.1.2011.2.25.3.20.20.10.40.1.8
Specifies the direction of monitoring. Only RCV(Receive direction)|TRMT(Transmit direction)|ALL will be represented here.
Status: current Access: read-only
OBJECT-TYPE    
  DirectionType  

pm1dayHisDataInterval 1.3.6.1.4.1.2011.2.25.3.20.20.10.40.1.9
The period number.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

pm1dayHisDataMonVal 1.3.6.1.4.1.2011.2.25.3.20.20.10.40.1.10
Measured value.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

pm1dayHisDataVldty 1.3.6.1.4.1.2011.2.25.3.20.20.10.40.1.11
It indicates whether the information for the specified time period was accumulated over the entire time period or some portion of it. Only INVALID|VALID will be represented here.
Status: current Access: read-only
OBJECT-TYPE    
  ValidflagType  

pm1dayHisDataStartTime 1.3.6.1.4.1.2011.2.25.3.20.20.10.40.1.12
The beginning date and time of the PM period.
Status: current Access: read-only
OBJECT-TYPE    
  DateAndTime  

optixSonetPmConformance 1.3.6.1.4.1.2011.2.25.3.20.20.20
OBJECT IDENTIFIER    

optixSonetPmGroups 1.3.6.1.4.1.2011.2.25.3.20.20.20.1
OBJECT IDENTIFIER    

optixSonetPmObjectGroup 1.3.6.1.4.1.2011.2.25.3.20.20.20.1.1
Enter the description of the created OBJECT-GROUP.
Status: current Access: read-only
OBJECT-GROUP    

optixSonetPmCompliances 1.3.6.1.4.1.2011.2.25.3.20.20.20.2
OBJECT IDENTIFIER    

optixSonetPmBasicCompliance 1.3.6.1.4.1.2011.2.25.3.20.20.20.2.1
Enter the description of the created MODULE-COMPLIANCE.
Status: current Access: read-only
MODULE-COMPLIANCE