OPTIX-SONET-PATH-MIB-V2

File: OPTIX-SONET-PATH-MIB-V2.mib (16753 bytes)

Imported modules

OPTIX-OID-MIB SNMPv2-CONF SNMPv2-SMI
SNMPv2-TC

Imported symbols

optixProvisionSonet OBJECT-GROUP MODULE-COMPLIANCE
Gauge32 OBJECT-TYPE MODULE-IDENTITY
TEXTUAL-CONVENTION

Defined Types

C2Value  
Enter the description for the C2Value TEXTUAL-CONVENTION converted from type assignment.
TEXTUAL-CONVENTION    
  INTEGER eqpd(1), vt-sts1(2), lock-vt(3), ds3(4), ds4na(18), atm(19), dqdb(20), fddi(21), hdlc-over-sonet(22), laps(24), gfp(27), pdi-1(225), pdi-2(226), pdi-3(227), pdi-4(228), pdi-5(229), pdi-6(230), pdi-7(231), pdi-8(232), pdi-9(233), pdi-10(234), pdi-11(235), pdi-12(236), pdi-13(237), pdi-14(238), pdi-15(239), pdi-16(240), pdi-17(241), pdi-18(242), pdi-19(243), pdi-20(244), pdi-21(245), pdi-22(246), pdi-23(247), pdi-24(248), pdi-29(249), pdi-26(250), pdi-27(251), pdi-28(252), uneq(253), o-181(254), invalid(65534)  

LpbkType  
Enter the description for the LpbkType TEXTUAL-CONVENTION converted from type assignment.
TEXTUAL-CONVENTION    
  INTEGER terminal(1), facility(2), crs(3), ds1feac(4), ds3feac(5), fac2ni(6), noloop(255)  

OptixsonetStsPathEntry  
SEQUENCE    
  stsPathLevel INTEGER
  stsPathBid Gauge32
  stsPathPid Gauge32
  stsPathStsId Gauge32
  stsPathRevertiveMode INTEGER
  stsPathRevertiveTime Gauge32
  stsPathSwitchConditon INTEGER
  stsPathDelayTime Gauge32
  stsPathSFBER INTEGER
  stsPathSDBER INTEGER
  stsPathJ1TRCMODE INTEGER
  stsPathTRCJ1 OCTET STRING
  stsPathEXPTRCJ1 OCTET STRING
  stsPathINCTRCJ1 OCTET STRING
  stsPathTRCC2 C2Value
  stsPathEXPTRCC2 C2Value
  stsPathINCTRCC2 C2Value
  stsPathSQL INTEGER
  stsPathSwitchState INTEGER
  stsPathPST OCTET STRING
  stsPathSST OCTET STRING
  stsPathLoopbackStatus LpbkType

Defined Values

optixsonetPathAttrib 1.3.6.1.4.1.2011.2.25.4.20.5
Enter the description for this MIB module.
MODULE-IDENTITY    

optixsonetStsPathTable 1.3.6.1.4.1.2011.2.25.4.20.5.1
This table describes the STS path management interface of Huawei SONET transmit platform
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OptixsonetStsPathEntry

optixsonetStsPathEntry 1.3.6.1.4.1.2011.2.25.4.20.5.1.1
The STS path management entry
Status: current Access: not-accessible
OBJECT-TYPE    
  OptixsonetStsPathEntry  

stsPathLevel 1.3.6.1.4.1.2011.2.25.4.20.5.1.1.1
The path level that identifies the type of STS path.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER levelSTS1(9), levelSTS3c(10), levelSTS6c(11), levelSTS9c(12), levelSTS12c(13), levelSTS15c(14), levelSTS24c(15), levelSTS48c(16), levelSTS192c(17)  

stsPathBid 1.3.6.1.4.1.2011.2.25.4.20.5.1.1.2
Slot number. This will indicate what is the slot of the object.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

stsPathPid 1.3.6.1.4.1.2011.2.25.4.20.5.1.1.3
Port Number. This will indicate what is the Port of the object.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

stsPathStsId 1.3.6.1.4.1.2011.2.25.4.20.5.1.1.4
Sts Number. This will indicate what is the Sts of the object.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

stsPathRevertiveMode 1.3.6.1.4.1.2011.2.25.4.20.5.1.1.5
A revertive mode. It only applies to UPSR.Valid values are shown below. Value Description Y Revertive mode. N No-revertive mode.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2), null(254)  

stsPathRevertiveTime 1.3.6.1.4.1.2011.2.25.4.20.5.1.1.6
Revertive time. It only applies to UPSR.Valid values are shown below. Value Description 5 to 12 Revertive time of UPSR, ranging from 5 to 12 minutes, default is 5 minutes, in increments of 1 minute.
Status: current Access: read-write
OBJECT-TYPE    
  Gauge32  

stsPathSwitchConditon 1.3.6.1.4.1.2011.2.25.4.20.5.1.1.7
Optional switching condition. Valid value is Y (switch when existing PDI-P) or N (do not switch when existing PDI-P).Default value is N.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2), null(255)  

stsPathDelayTime 1.3.6.1.4.1.2011.2.25.4.20.5.1.1.8
Delay time is hold-off time. It is an integer. Valid value ranges from 0 to 255. Unit is 100 ms. Default value is 0.Delay times are useful for interworking of protection schemes. For example, an optical port is configured for both UPSR and BLSR simultaneously. After the delay time is set, when a defect condition is declared on the port, the UPSR switching is not initiated. When the timer expires, the UPSR switching is initiated if the defect condition is still present at this point. When only one kind of protection UPSR is configured, just use the default value.
Status: current Access: read-write
OBJECT-TYPE    
  Gauge32  

stsPathSFBER 1.3.6.1.4.1.2011.2.25.4.20.5.1.1.9
Threshold of path (B3) SFBER on a facility. Valid values are shown below. Value Description 1E-3 to 1E-5 SFBER ranges from 1E-3 to 1E-5, Default threshold is 1E-4. 1E-5 to 1E-9 SDBER ranges from 1E-5 to 1E-9, Default threshold is 1E-6.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER sf1E-3(3), sf1E-4(4), sf1E-5(5)  

stsPathSDBER 1.3.6.1.4.1.2011.2.25.4.20.5.1.1.10
Threshold of path (B3) SDBER on a facility. Valid values are shown below. Value Description 1E-3 to 1E-5 SFBER ranges from 1E-3 to 1E-5, Default threshold is 1E-4. 1E-5 to 1E-9 SDBER ranges from 1E-5 to 1E-9, Default threshold is 1E-6.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER sd1E-5(5), sd1E-6(6), sd1E-7(7), sd1E-8(8), sd1E-9(9)  

stsPathJ1TRCMODE 1.3.6.1.4.1.2011.2.25.4.20.5.1.1.11
Path trace mode. Valid values are shown below. Value Description MANUAL Performs the comparison of the received string with the user-entered expected string. AUTO Performs the comparison of the present received string with an expected string set to a previously received string. If there is a mismatch, TIM-P alarm is raised. OFF Don't perform the comparison. Default value is OFF.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER manual(1), auto(2), off(3), invalid(254)  

stsPathTRCJ1 1.3.6.1.4.1.2011.2.25.4.20.5.1.1.12
The path trace message contents (J1) to be transmitted.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..62)  

stsPathEXPTRCJ1 1.3.6.1.4.1.2011.2.25.4.20.5.1.1.13
The expected path traces message (J1) contents.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..62)  

stsPathINCTRCJ1 1.3.6.1.4.1.2011.2.25.4.20.5.1.1.14
The path trace message received. It can not include escape characters except \ and .
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..62)  

stsPathTRCC2 1.3.6.1.4.1.2011.2.25.4.20.5.1.1.15
The C2 byte hex code to be transmitted. Valid values are shown below. Value Description UNEQ 0x00 The C2 content to be transmitted is unloaded. EQPD (default) 0x01 The C2 content to be transmitted is loaded with normal SPE. VT-STS1 0x02 The C2 content to be transmitted: STS-1 SPE of VT structure. Default value for C2 in DS1 unit LOCK-VT 0x03 The C2 content to be transmitted: lock VT mode. DS3 0x04 The C2 content to be transmitted: DS3 asynchronous mapping. Default value for C2 in DS3 port. DS4NA 0x12 The C2 content to be transmitted: DS4NA asynchronous mapping. ATM 0x13 The C2 content to be transmitted: ATM mapping. DQDB 0x14 The C2 content to be transmitted: DQDB mapping. FDDI 0x15 The C2 content to be transmitted: FDDI asynchronous mapping. HDLC-OVER-SONET 0x16 The C2 content to be transmitted: HDLC-OVER-SONET mapping. LAPS 0x18 GFP 0x1b O.181 0xfe The C2 content to be transmitted: O.181 testing signal. Other byte Hex code Non standard C2.
Status: current Access: read-write
OBJECT-TYPE    
  C2Value  

stsPathEXPTRCC2 1.3.6.1.4.1.2011.2.25.4.20.5.1.1.16
The expected C2 byte hex code. Valid values are shown below. Value Description UNEQ 0x00 The C2 content to be transmitted is unloaded. EQPD (default) 0x01 The C2 content to be transmitted is loaded with normal SPE. VT-STS1 0x02 The C2 content to be transmitted: STS-1 SPE of VT structure. Default value for C2 in DS1 unit LOCK-VT 0x03 The C2 content to be transmitted: lock VT mode. DS3 0x04 The C2 content to be transmitted: DS3 asynchronous mapping. Default value for C2 in DS3 port. DS4NA 0x12 The C2 content to be transmitted: DS4NA asynchronous mapping. ATM 0x13 The C2 content to be transmitted: ATM mapping. DQDB 0x14 The C2 content to be transmitted: DQDB mapping. FDDI 0x15 The C2 content to be transmitted: FDDI asynchronous mapping. HDLC-OVER-SONET 0x16 The C2 content to be transmitted: HDLC-OVER-SONET mapping. LAPS 0x18 GFP 0x1b O.181 0xfe The C2 content to be transmitted: O.181 testing signal. Other byte Hex code Non standard C2.
Status: current Access: read-write
OBJECT-TYPE    
  C2Value  

stsPathINCTRCC2 1.3.6.1.4.1.2011.2.25.4.20.5.1.1.17
The C2 byte hex code received. Valid values are shown below. Value Description UNEQ 0x00 The C2 content to be transmitted is unloaded. EQPD (default) 0x01 The C2 content to be transmitted is loaded with normal SPE. VT-STS1 0x02 The C2 content to be transmitted: STS-1 SPE of VT structure. Default value for C2 in DS1 unit LOCK-VT 0x03 The C2 content to be transmitted: lock VT mode. DS3 0x04 The C2 content to be transmitted: DS3 asynchronous mapping. Default value for C2 in DS3 port. DS4NA 0x12 The C2 content to be transmitted: DS4NA asynchronous mapping. ATM 0x13 The C2 content to be transmitted: ATM mapping. DQDB 0x14 The C2 content to be transmitted: DQDB mapping. FDDI 0x15 The C2 content to be transmitted: FDDI asynchronous mapping. HDLC-OVER-SONET 0x16 The C2 content to be transmitted: HDLC-OVER-SONET mapping. LAPS 0x18 GFP 0x1b O.181 0xfe The C2 content to be transmitted: O.181 testing signal. Other byte Hex code Non standard C2.
Status: current Access: read-only
OBJECT-TYPE    
  C2Value  

stsPathSQL 1.3.6.1.4.1.2011.2.25.4.20.5.1.1.18
The flag of squelch. This parameter only supplies for BLSR. Valid value is Y or N.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER yes(1), no(2), invalid(254)  

stsPathSwitchState 1.3.6.1.4.1.2011.2.25.4.20.5.1.1.19
It is only valid when the port is in the UPSR protection group. Valid values are shown below. Value Description IDLE Idle WTR Wait to restore AUTOSW Automatic switch MANPtoW Manually switch to the working unit MANWtoP Manually switch to the protecting unit FRCPtoW Forced switch to the working unit FRCWtoP Forced switch to the protecting unit LOCKOUT Lock to the working unit CLEAR Clear INVALID Invalid
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER wtr(1), autosw(2), manPtoW(3), manWtoP(4), frcPtoW(5), frcWtoP(6), lockout(7), clear(8), idle(253), invalid(254)  

stsPathPST 1.3.6.1.4.1.2011.2.25.4.20.5.1.1.20
means the primary state of the entity. Valid values are IS-NR, OOS-AU, OOS-MA and OOS-AUMA.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..16)  

stsPathSST 1.3.6.1.4.1.2011.2.25.4.20.5.1.1.21
means the secondary state of the entity. Valid values are MT, LPBK, SGEO and FAF,
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..32)  

stsPathLoopbackStatus 1.3.6.1.4.1.2011.2.25.4.20.5.1.1.22
This variable represents the current state of the loopback on the sts path.
Status: current Access: read-write
OBJECT-TYPE    
  LpbkType  

optixsonetPathAttribConformance 1.3.6.1.4.1.2011.2.25.4.20.5.2
OBJECT IDENTIFIER    

optixsonetPathAttribGroups 1.3.6.1.4.1.2011.2.25.4.20.5.2.1
OBJECT IDENTIFIER    

currentObjectGroup 1.3.6.1.4.1.2011.2.25.4.20.5.2.1.1
Enter the description of the created OBJECT-GROUP.
Status: current Access: read-write
OBJECT-GROUP    

optixsonetPathAttribCompliances 1.3.6.1.4.1.2011.2.25.4.20.5.2.2
OBJECT IDENTIFIER    

basicCompliance 1.3.6.1.4.1.2011.2.25.4.20.5.2.2.1
Enter the description of the created MODULE-COMPLIANCE.
Status: current Access: read-write
MODULE-COMPLIANCE