ONEACCESS-UPS-MIB

File: ONEACCESS-UPS-MIB.mib (4984 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC SNMPv2-CONF
ONEACCESS-GLOBAL-REG

Imported symbols

MODULE-IDENTITY OBJECT-TYPE NOTIFICATION-TYPE
OBJECT-IDENTITY Counter32 Gauge32
Integer32 DisplayString TimeStamp
TimeInterval TestAndIncr AutonomousType
MODULE-COMPLIANCE OBJECT-GROUP oacExpIMManagement

Defined Values

oacUpsMIB 1.3.6.1.4.1.13191.10.3.4.1225
The MIB module to describe Uninterruptible Power Supplies.
MODULE-IDENTITY    

oacUpsMIBObjects 1.3.6.1.4.1.13191.10.3.4.1225.1
OBJECT IDENTIFIER    

oacUpsBattery 1.3.6.1.4.1.13191.10.3.4.1225.1.1
OBJECT IDENTIFIER    

oacUpsBatteryStatus 1.3.6.1.4.1.13191.10.3.4.1225.1.1.1
The indication of the capacity remaining in the UPS system's batteries. A value of batteryNormal indicates that the remaining run-time is greater than upsConfigLowBattTime. A value of batteryLow indicates that the remaining battery run-time is less than or equal to upsConfigLowBattTime. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is currently absent and the UPS is unable to sustain the output).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), batteryNormal(2), batteryLow(3), batteryDepleted(4)  

oacUpsAlarm 1.3.6.1.4.1.13191.10.3.4.1225.1.2
OBJECT IDENTIFIER    

oacUpsAlarmsPresent 1.3.6.1.4.1.13191.10.3.4.1225.1.2.1
The present number of active alarm conditions.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

oacUpsAlarmDescr 1.3.6.1.4.1.13191.10.3.4.1225.1.2.2
A reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition.
Status: current Access: read-only
OBJECT-TYPE    
  AutonomousType  

oacUpsAlarmTime 1.3.6.1.4.1.13191.10.3.4.1225.1.2.3
The value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before agent startup, the value of upsAlarmTime shall equal 0.
Status: current Access: read-only
OBJECT-TYPE    
  TimeStamp  

oacUpsTraps 1.3.6.1.4.1.13191.10.3.4.1225.2
OBJECT IDENTIFIER    

oacUpsTrapAlarmEntryAdded 1.3.6.1.4.1.13191.10.3.4.1225.2.0
This trap is sent each time an alarm is inserted into to the alarm table. It is sent on the insertion of all alarms except for upsAlarmOnBattery and upsAlarmTestInProgress.
Status: current Access: read-only
NOTIFICATION-TYPE    

oacUpsTrapAlarmEntryRemoved 1.3.6.1.4.1.13191.10.3.4.1225.2.1
This trap is sent each time an alarm is removed from the alarm table. It is sent on the removal of all alarms except for upsAlarmTestInProgress.
Status: current Access: read-only
NOTIFICATION-TYPE