ONEACCESS-OAM-MIB

File: ONEACCESS-OAM-MIB.mib (17319 bytes)

Imported modules

SNMPv2-SMI RFC1213-MIB SNMPv2-CONF
SNMPv2-TC IF-MIB ATM-MIB
ONEACCESS-GLOBAL-REG

Imported symbols

MODULE-IDENTITY OBJECT-TYPE Counter32
Unsigned32 Integer32 IpAddress
DisplayString MODULE-COMPLIANCE OBJECT-GROUP
TimeStamp TimeInterval InterfaceIndex
ifIndex atmVclEntry oacExpIMAtmOamStatistics
oacMIBModules

Defined Types

OacAtmOamVclEntry  
SEQUENCE    
  oacAtmOamVclPvcManage INTEGER
  oacAtmOamVclSegmentLoopback INTEGER
  oacAtmOamVclEndLoopback INTEGER
  oacAtmOamVclAisRdiEnable INTEGER
  oacAtmOamVclSegmentContinuityCheckEnable INTEGER
  oacAtmOamVclEndContinuityCheckEnable INTEGER
  oacAtmOamVclLoopbackTxInterval Integer32
  oacAtmOamVclLoopbackTxRetryFrequency Integer32
  oacAtmOamVclLoopbackTxRetryUpCount Integer32
  oacAtmOamVclLoopbackTxRetryDownCount Integer32
  oacAtmOamVclAlarmState Integer32
  oacAtmOamVclAlarmStateLastChange TimeStamp
  oacAtmOamVclAisRdiRetryDownCount Integer32
  oacAtmOamVclAisRdiRetryUpTimer Integer32
  oacAtmOamVclPvcIntrusive INTEGER

OacAtmOamVclCountersEntry  
SEQUENCE    
  oacAtmOamVclOamCellsReceived Counter32
  oacAtmOamVclEndLoopbackIn Counter32
  oacAtmOamVclSegLoopbackIn Counter32
  oacAtmOamVclEndLoopIn Counter32
  oacAtmOamVclSegLoopIn Counter32
  oacAtmOamVclAisIn Counter32
  oacAtmOamVclRdiIn Counter32
  oacAtmOamVclSegCCIn Counter32
  oacAtmOamVclEndCCIn Counter32
  oacAtmOamVclOamCellsSent Counter32
  oacAtmOamVclEndLoopbackOut Counter32
  oacAtmOamVclSegLoopbackOut Counter32
  oacAtmOamVclEndLoopOut Counter32
  oacAtmOamVclSegLoopOut Counter32
  oacAtmOamVclAisOut Counter32
  oacAtmOamVclRdiOut Counter32
  oacAtmOamVclSegCCOut Counter32
  oacAtmOamVclEndCCOut Counter32
  oacAtmOamVclOamCellsDropped Counter32

Defined Values

oacOamMIBModule 1.3.6.1.4.1.13191.1.100.673
Contact updated
MODULE-IDENTITY    

oacAtmOamStatObjects 1.3.6.1.4.1.13191.10.3.2.2.1
OBJECT IDENTIFIER    

oacAtmOamStatNotifications 1.3.6.1.4.1.13191.10.3.2.2.2
OBJECT IDENTIFIER    

oacAtmOamStatConformance 1.3.6.1.4.1.13191.10.3.2.2.3
OBJECT IDENTIFIER    

oacAtmOamStatSwitch 1.3.6.1.4.1.13191.10.3.2.2.1.1
OBJECT IDENTIFIER    

oacAtmOamSwitchMaxConnections 1.3.6.1.4.1.13191.10.3.2.2.1.1.1
Maximum number of authorised OAM configured connections
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

oacAtmOamSwitchSegLoopback 1.3.6.1.4.1.13191.10.3.2.2.1.1.2
Enable segment loopback on this switch
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

oacAtmOamSwitchEndLoopback 1.3.6.1.4.1.13191.10.3.2.2.1.1.3
Enable end to end loopback on this switch
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

oacAtmOamSwitchAisRdiEnable 1.3.6.1.4.1.13191.10.3.2.2.1.1.4
Enable Remote Defect Indication OAM cell generation if an Alarm Indication Signal OAM cell is received, or if a defect is detected on the switch
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

oacAtmOamSwitchSegmentContinuityCheckEnable 1.3.6.1.4.1.13191.10.3.2.2.1.1.5
Enable Segment Loss of Continuity cells defect on the pvc. Enable generation of segment Continuity Check cells on the switch.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

oacAtmOamSwitchEndContinuityCheckEnable 1.3.6.1.4.1.13191.10.3.2.2.1.1.6
Enable End to End Loss of Continuity cells defect on the pvc. Enable generation of End to End Continuity Check cells on the switch.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

oacAtmOamSwitchOamCellsReceived 1.3.6.1.4.1.13191.10.3.2.2.1.1.7
Number of received OAM cells on the switch
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

oacAtmOamSwitchOamCellsTransmitted 1.3.6.1.4.1.13191.10.3.2.2.1.1.8
Number of transmitted OAM cells on the switch
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

oacAtmOamSwitchCurrentConnections 1.3.6.1.4.1.13191.10.3.2.2.1.1.9
Current number of OAM configured connections
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

oacAtmOamVclTable 1.3.6.1.4.1.13191.10.3.2.2.1.2
An index into the table oacAtmOamVclTable
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OacAtmOamVclEntry

oacAtmOamVclEntry 1.3.6.1.4.1.13191.10.3.2.2.1.2.1
An index into the table oacAtmOamVclTable
Status: current Access: not-accessible
OBJECT-TYPE    
  OacAtmOamVclEntry  

oacAtmOamVclPvcManage 1.3.6.1.4.1.13191.10.3.2.2.1.2.1.1
Enable OAM for Pvc management
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

oacAtmOamVclSegmentLoopback 1.3.6.1.4.1.13191.10.3.2.2.1.2.1.2
Enable segment loopback on this virtual channel
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

oacAtmOamVclEndLoopback 1.3.6.1.4.1.13191.10.3.2.2.1.2.1.3
Enable end to end loopback on this virtual channel
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

oacAtmOamVclAisRdiEnable 1.3.6.1.4.1.13191.10.3.2.2.1.2.1.4
Enable Remote Defect Indication OAM cell generation if an Alarm Indication Signal OAM cell is received, or if a defect is detected on the PVC
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

oacAtmOamVclSegmentContinuityCheckEnable 1.3.6.1.4.1.13191.10.3.2.2.1.2.1.5
Enable Segment Loss of Continuity cells detect on the PVC.Enable generation of Segment Continuity Check cells on the PVC.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

oacAtmOamVclEndContinuityCheckEnable 1.3.6.1.4.1.13191.10.3.2.2.1.2.1.6
Enable End to End Loss of Continuity cells detect on the PVC.Enable generation of End to End Continuity Check cells on the PVC.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

oacAtmOamVclLoopbackTxInterval 1.3.6.1.4.1.13191.10.3.2.2.1.2.1.7
Frequency of OAM loopback cell are generated on this virtual channel
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

oacAtmOamVclLoopbackTxRetryFrequency 1.3.6.1.4.1.13191.10.3.2.2.1.2.1.8
Frequency of OAM loopback cell are generated on this virtual channel, when a change has occured, that is to say either no reception of the last loopback cell, or reception of the last loopback cell
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

oacAtmOamVclLoopbackTxRetryUpCount 1.3.6.1.4.1.13191.10.3.2.2.1.2.1.9
Counter of consecutive received loopback cells, before vcl is considered as being up
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

oacAtmOamVclLoopbackTxRetryDownCount 1.3.6.1.4.1.13191.10.3.2.2.1.2.1.10
Counter of consecutive non received loopback cells, before vcl is considered as being down
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

oacAtmOamVclAlarmState 1.3.6.1.4.1.13191.10.3.2.2.1.2.1.11
This object indicates the current alarm status of the VCL, when error monitoring is activated on the VCL. Value indicates the different alarm states tha the VCL can take. Those alarms can be combined together. The unknown state indicates that the alarm status of this VCL cannot be determined. cc_seg_loc(1),cc_ete_loc(2), lb_seg_alarm(4),lb_ete_alarm(8), ais_alarm(16),rdi_alarm(32),other(64)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

oacAtmOamVclAlarmStateLastChange 1.3.6.1.4.1.13191.10.3.2.2.1.2.1.12
The value of sysUpTime object at the time this VCL entered its current alarm status. If the current state was entered prior to the last re-initialization of the agent, then this object contains a zero value.
Status: current Access: read-only
OBJECT-TYPE    
  TimeStamp  

oacAtmOamVclAisRdiRetryDownCount 1.3.6.1.4.1.13191.10.3.2.2.1.2.1.13
Number of consecutive OAM AIS/RDI cells received. The range is 3 to 60. The default is 3.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

oacAtmOamVclAisRdiRetryUpTimer 1.3.6.1.4.1.13191.10.3.2.2.1.2.1.14
Number of seconds with no OAM AIS/RDI cells received. The range is 3 to 60 seconds . The default is 3 seconds.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

oacAtmOamVclPvcIntrusive 1.3.6.1.4.1.13191.10.3.2.2.1.2.1.15
Enable OAM Intrusivity against Pvc
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

oacAtmOamVclCountersTable 1.3.6.1.4.1.13191.10.3.2.2.1.3
An index into table oacAtmOamVclCountersTable
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OacAtmOamVclCountersEntry

oacAtmOamVclCountersEntry 1.3.6.1.4.1.13191.10.3.2.2.1.3.1
An index into table oacAtmOamVclCountersTable
Status: current Access: not-accessible
OBJECT-TYPE    
  OacAtmOamVclCountersEntry  

oacAtmOamVclOamCellsReceived 1.3.6.1.4.1.13191.10.3.2.2.1.3.1.1
Number of received oam cells
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

oacAtmOamVclEndLoopbackIn 1.3.6.1.4.1.13191.10.3.2.2.1.3.1.2
Number of received non looped end to end oam loopback cells
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

oacAtmOamVclSegLoopbackIn 1.3.6.1.4.1.13191.10.3.2.2.1.3.1.3
Number of received non looped segment oam loopback cells
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

oacAtmOamVclEndLoopIn 1.3.6.1.4.1.13191.10.3.2.2.1.3.1.4
Number of received looped end to end oam loopback cells
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

oacAtmOamVclSegLoopIn 1.3.6.1.4.1.13191.10.3.2.2.1.3.1.5
Number of received looped segment oam loopback cells
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

oacAtmOamVclAisIn 1.3.6.1.4.1.13191.10.3.2.2.1.3.1.6
Number of received oam ais cells
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

oacAtmOamVclRdiIn 1.3.6.1.4.1.13191.10.3.2.2.1.3.1.7
Number of received oam rdi cells
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

oacAtmOamVclSegCCIn 1.3.6.1.4.1.13191.10.3.2.2.1.3.1.8
Number of received oam end to end continuity check cells
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

oacAtmOamVclEndCCIn 1.3.6.1.4.1.13191.10.3.2.2.1.3.1.9
Number of received oam segment continuity check cells
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

oacAtmOamVclOamCellsSent 1.3.6.1.4.1.13191.10.3.2.2.1.3.1.10
Number of sent oam cells
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

oacAtmOamVclEndLoopbackOut 1.3.6.1.4.1.13191.10.3.2.2.1.3.1.11
Number of sent non looped end to end oam loopback cells
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

oacAtmOamVclSegLoopbackOut 1.3.6.1.4.1.13191.10.3.2.2.1.3.1.12
Number of sent non looped segment oam loopback cells
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

oacAtmOamVclEndLoopOut 1.3.6.1.4.1.13191.10.3.2.2.1.3.1.13
Number of sent looped end to end oam loopback cells
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

oacAtmOamVclSegLoopOut 1.3.6.1.4.1.13191.10.3.2.2.1.3.1.14
Number of sent looped segment oam loopback cells
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

oacAtmOamVclAisOut 1.3.6.1.4.1.13191.10.3.2.2.1.3.1.15
Number of sent oam ais cells
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

oacAtmOamVclRdiOut 1.3.6.1.4.1.13191.10.3.2.2.1.3.1.16
Number of sent oam rdi cells
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

oacAtmOamVclSegCCOut 1.3.6.1.4.1.13191.10.3.2.2.1.3.1.17
Number of sent oam end to end continuity check cells
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

oacAtmOamVclEndCCOut 1.3.6.1.4.1.13191.10.3.2.2.1.3.1.18
Number of sent oam segment continuity check cells
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

oacAtmOamVclOamCellsDropped 1.3.6.1.4.1.13191.10.3.2.2.1.3.1.19
Number of received oam cells that are ignored and dropped
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

oacAtmOamStatGroups 1.3.6.1.4.1.13191.10.3.2.2.3.1
OBJECT IDENTIFIER    

oacAtmOamStatCompliances 1.3.6.1.4.1.13191.10.3.2.2.3.2
OBJECT IDENTIFIER    

oacAtmOamStatCompliance 1.3.6.1.4.1.13191.10.3.2.2.3.2.1
The compliance statement for agents that support the ONEACCESS-OAM-MIB.
Status: current Access: read-only
MODULE-COMPLIANCE    

oacAtmOamStatGeneralGroup 1.3.6.1.4.1.13191.10.3.2.2.3.1.1
This group is mandatory for all OAM entities.
Status: current Access: read-only
OBJECT-GROUP