OMNI-gx2dualdrr2x-MIB

File: OMNI-gx2dualdrr2x-MIB.mib (150589 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC1213-MIB
RFC-1215 GX2HFC-MIB NLSBBN-TRAPS-MIB

Imported symbols

IpAddress TimeTicks Counter
OBJECT-TYPE DisplayString TRAP-TYPE
gx2DualDrr2x trapIdentifier trapNetworkElemModelNumber
trapNetworkElemSerialNum trapPerceivedSeverity trapNetworkElemOperState
trapNetworkElemAlarmStatus trapNetworkElemAdminState trapNetworkElemAvailStatus
trapText trapNETrapLastTrapTimeStamp trapChangedObjectId
trapChangedValueInteger trapChangedValueDisplayString

Defined Types

Float  
Counter    

Gx2dualdrr2xAnalogEntry  
SEQUENCE    
  gx2dualdrr2xAnalogTableIndex INTEGER
  dualdrr2xlabelRecdOptPwr1 DisplayString Size(0..80)
  dualdrr2xuomRecdOptPwr1 DisplayString Size(0..80)
  dualdrr2xmajorHighRecdOptPwr1 Float
  dualdrr2xmajorLowRecdOptPwr1 Float
  dualdrr2xminorHighRecdOptPwr1 Float
  dualdrr2xminorLowRecdOptPwr1 Float
  dualdrr2xcurrentValueRecdOptPwr1 Float
  dualdrr2xstateFlagRecdOptPwr1 INTEGER
  dualdrr2xminValueRecdOptPwr1 Float
  dualdrr2xmaxValueRecdOptPwr1 Float
  dualdrr2xalarmStateRecdOptPwr1 INTEGER
  dualdrr2xlabelRecdOptPwr2 DisplayString Size(0..80)
  dualdrr2xuomRecdOptPwr2 DisplayString Size(0..80)
  dualdrr2xmajorHighRecdOptPwr2 Float
  dualdrr2xmajorLowRecdOptPwr2 Float
  dualdrr2xminorHighRecdOptPwr2 Float
  dualdrr2xminorLowRecdOptPwr2 Float
  dualdrr2xcurrentValueRecdOptPwr2 Float
  dualdrr2xstateFlagRecdOptPwr2 INTEGER
  dualdrr2xminValueRecdOptPwr2 Float
  dualdrr2xmaxValueRecdOptPwr2 Float
  dualdrr2xalarmStateRecdOptPwr2 INTEGER
  dualdrr2xlabelModTemp DisplayString Size(0..80)
  dualdrr2xuomModTemp DisplayString Size(0..80)
  dualdrr2xmajorHighModTemp Float
  dualdrr2xmajorLowModTemp Float
  dualdrr2xminorHighModTemp Float
  dualdrr2xminorLowModTemp Float
  dualdrr2xcurrentValueModTemp Float
  dualdrr2xstateFlagModTemp INTEGER
  dualdrr2xminValueModTemp Float
  dualdrr2xmaxValueModTemp Float
  dualdrr2xalarmStateModTemp INTEGER
  dualdrr2xlabel12VCurrent DisplayString Size(0..80)
  dualdrr2xuom12VCurrent DisplayString Size(0..80)
  dualdrr2xmajorHigh12VCurrent Float
  dualdrr2xmajorLow12VCurrent Float
  dualdrr2xminorHigh12VCurrent Float
  dualdrr2xminorLow12VCurrent Float
  dualdrr2xcurrentValue12VCurrent Float
  dualdrr2xstateFlag12VCurrent INTEGER
  dualdrr2xminValue12VCurrent Float
  dualdrr2xmaxValue12VCurrent Float
  dualdrr2xalarmState12VCurrent INTEGER
  dualdrr2xlabelFanSpeed DisplayString Size(0..80)
  dualdrr2xuomFanSpeed DisplayString Size(0..80)
  dualdrr2xmajorHighFanSpeed Float
  dualdrr2xmajorLowFanSpeed Float
  dualdrr2xminorHighFanSpeed Float
  dualdrr2xminorLowFanSpeed Float
  dualdrr2xcurrentValueFanSpeed Float
  dualdrr2xstateFlagFanSpeed INTEGER
  dualdrr2xminValueFanSpeed Float
  dualdrr2xmaxValueFanSpeed Float
  dualdrr2xalarmStateFanSpeed INTEGER
  dualdrr2xlabelTx0SFPWave DisplayString Size(0..80)
  dualdrr2xuomTx0SFPWave DisplayString Size(0..80)
  dualdrr2xmajorHighTx0SFPWave Float
  dualdrr2xmajorLowTx0SFPWave Float
  dualdrr2xminorHighTx0SFPWave Float
  dualdrr2xminorLowTx0SFPWave Float
  dualdrr2xcurrentValueTx0SFPWave Float
  dualdrr2xstateFlagTx0SFPWave INTEGER
  dualdrr2xminValueTx0SFPWave Float
  dualdrr2xmaxValueTx0SFPWave Float
  dualdrr2xalarmStateTx0SFPWave INTEGER
  dualdrr2xlabelTx0OptPwr DisplayString Size(0..80)
  dualdrr2xuomTx0OptPwr DisplayString Size(0..80)
  dualdrr2xmajorHighTx0OptPwr Float
  dualdrr2xmajorLowTx0OptPwr Float
  dualdrr2xminorHighTx0OptPwr Float
  dualdrr2xminorLowTx0OptPwr Float
  dualdrr2xcurrentValueTx0OptPwr Float
  dualdrr2xstateFlagTx0OptPwr INTEGER
  dualdrr2xminValueTx0OptPwr Float
  dualdrr2xmaxValueTx0OptPwr Float
  dualdrr2xalarmStateTx0OptPwr INTEGER
  dualdrr2xlabelTx024vCurr DisplayString Size(0..80)
  dualdrr2xuomTx024vCurr DisplayString Size(0..80)
  dualdrr2xmajorHighTx024vCurr Float
  dualdrr2xmajorLowTx024vCurr Float
  dualdrr2xminorHighTx024vCurr Float
  dualdrr2xminorLowTx024vCurr Float
  dualdrr2xcurrentValueTx024vCurr Float
  dualdrr2xstateFlagTx024vCurr INTEGER
  dualdrr2xminValueTx024vCurr Float
  dualdrr2xmaxValueTx024vCurr Float
  dualdrr2xalarmStateTx024vCurr INTEGER
  dualdrr2xlabelTx024Volt DisplayString Size(0..80)
  dualdrr2xuomTx024Volt DisplayString Size(0..80)
  dualdrr2xmajorHighTx024Volt Float
  dualdrr2xmajorLowTx024Volt Float
  dualdrr2xminorHighTx024Volt Float
  dualdrr2xminorLowTx024Volt Float
  dualdrr2xcurrentValueTx024Volt Float
  dualdrr2xstateFlagTx024Volt INTEGER
  dualdrr2xminValueTx024Volt Float
  dualdrr2xmaxValueTx024Volt Float
  dualdrr2xalarmStateTx024Volt INTEGER
  dualdrr2xlabelTx0ModTemp DisplayString Size(0..80)
  dualdrr2xuomTx0ModTemp DisplayString Size(0..80)
  dualdrr2xmajorHighTx0ModTemp Float
  dualdrr2xmajorLowTx0ModTemp Float
  dualdrr2xminorHighTx0ModTemp Float
  dualdrr2xminorLowTx0ModTemp Float
  dualdrr2xcurrentValueTx0ModTemp Float
  dualdrr2xstateFlagTx0ModTemp INTEGER
  dualdrr2xminValueTx0ModTemp Float
  dualdrr2xmaxValueTx0ModTemp Float
  dualdrr2xalarmStateTx0ModTemp INTEGER
  dualdrr2xlabelTx1SFPWave DisplayString Size(0..80)
  dualdrr2xuomTx1SFPWave DisplayString Size(0..80)
  dualdrr2xmajorHighTx1SFPWave Float
  dualdrr2xmajorLowTx1SFPWave Float
  dualdrr2xminorHighTx1SFPWave Float
  dualdrr2xminorLowTx1SFPWave Float
  dualdrr2xcurrentValueTx1SFPWave Float
  dualdrr2xstateFlagTx1SFPWave INTEGER
  dualdrr2xminValueTx1SFPWave Float
  dualdrr2xmaxValueTx1SFPWave Float
  dualdrr2xalarmStateTx1SFPWave INTEGER
  dualdrr2xlabelTx1OptPwr DisplayString Size(0..80)
  dualdrr2xuomTx1OptPwr DisplayString Size(0..80)
  dualdrr2xmajorHighTx1OptPwr Float
  dualdrr2xmajorLowTx1OptPwr Float
  dualdrr2xminorHighTx1OptPwr Float
  dualdrr2xminorLowTx1OptPwr Float
  dualdrr2xcurrentValueTx1OptPwr Float
  dualdrr2xstateFlagTx1OptPwr INTEGER
  dualdrr2xminValueTx1OptPwr Float
  dualdrr2xmaxValueTx1OptPwr Float
  dualdrr2xalarmStateTx1OptPwr INTEGER
  dualdrr2xlabelTx124vCurr DisplayString Size(0..80)
  dualdrr2xuomTx124vCurr DisplayString Size(0..80)
  dualdrr2xmajorHighTx124vCurr Float
  dualdrr2xmajorLowTx124vCurr Float
  dualdrr2xminorHighTx124vCurr Float
  dualdrr2xminorLowTx124vCurr Float
  dualdrr2xcurrentValueTx124vCurr Float
  dualdrr2xstateFlagTx124vCurr INTEGER
  dualdrr2xminValueTx124vCurr Float
  dualdrr2xmaxValueTx124vCurr Float
  dualdrr2xalarmStateTx124vCurr INTEGER
  dualdrr2xlabelTx124Volt DisplayString Size(0..80)
  dualdrr2xuomTx124Volt DisplayString Size(0..80)
  dualdrr2xmajorHighTx124Volt Float
  dualdrr2xmajorLowTx124Volt Float
  dualdrr2xminorHighTx124Volt Float
  dualdrr2xminorLowTx124Volt Float
  dualdrr2xcurrentValueTx124Volt Float
  dualdrr2xstateFlagTx124Volt INTEGER
  dualdrr2xminValueTx124Volt Float
  dualdrr2xmaxValueTx124Volt Float
  dualdrr2xalarmStateTx124Volt INTEGER
  dualdrr2xlabelTx1ModTemp DisplayString Size(0..80)
  dualdrr2xuomTx1ModTemp DisplayString Size(0..80)
  dualdrr2xmajorHighTx1ModTemp Float
  dualdrr2xmajorLowTx1ModTemp Float
  dualdrr2xminorHighTx1ModTemp Float
  dualdrr2xminorLowTx1ModTemp Float
  dualdrr2xcurrentValueTx1ModTemp Float
  dualdrr2xstateFlagTx1ModTemp INTEGER
  dualdrr2xminValueTx1ModTemp Float
  dualdrr2xmaxValueTx1ModTemp Float
  dualdrr2xalarmStateTx1ModTemp INTEGER

Gx2dualdrr2xDigitalEntry  
SEQUENCE    
  gx2dualdrr2xDigitalTableIndex INTEGER
  dualdrr2xlabelTrippoint1Value DisplayString Size(0..80)
  dualdrr2xenumTrippoint1Value DisplayString Size(0..80)
  dualdrr2xvalueTrippoint1Value INTEGER
  dualdrr2xstateflagTrippoint1Value INTEGER
  dualdrr2xlabelTrippoint1Mode DisplayString Size(0..80)
  dualdrr2xenumTrippoint1Mode DisplayString Size(0..80)
  dualdrr2xvalueTrippoint1Mode INTEGER
  dualdrr2xstateflagTrippoint1Mode INTEGER
  dualdrr2xlabelTrippoint2Value DisplayString Size(0..80)
  dualdrr2xenumTrippoint2Value DisplayString Size(0..80)
  dualdrr2xvalueTrippoint2Value INTEGER
  dualdrr2xstateflagTrippoint2Value INTEGER
  dualdrr2xlabelTrippoint2Mode DisplayString Size(0..80)
  dualdrr2xenumTrippoint2Mode DisplayString Size(0..80)
  dualdrr2xvalueTrippoint2Mode INTEGER
  dualdrr2xstateflagTrippoint2Mode INTEGER
  dualdrr2xlabelGainChannel1A DisplayString Size(0..80)
  dualdrr2xenumGainChannel1A DisplayString Size(0..80)
  dualdrr2xvalueGainChannel1A INTEGER
  dualdrr2xstateflagGainChannel1A INTEGER
  dualdrr2xlabelGainChannel1B DisplayString Size(0..80)
  dualdrr2xenumGainChannel1B DisplayString Size(0..80)
  dualdrr2xvalueGainChannel1B INTEGER
  dualdrr2xstateflagGainChannel1B INTEGER
  dualdrr2xlabelGainChannel2A DisplayString Size(0..80)
  dualdrr2xenumGainChannel2A DisplayString Size(0..80)
  dualdrr2xvalueGainChannel2A INTEGER
  dualdrr2xstateflagGainChannel2A INTEGER
  dualdrr2xlabelGainChannel2B DisplayString Size(0..80)
  dualdrr2xenumGainChannel2B DisplayString Size(0..80)
  dualdrr2xvalueGainChannel2B INTEGER
  dualdrr2xstateflagGainChannel2B INTEGER
  dualdrr2xlabelTestpointSelect DisplayString Size(0..80)
  dualdrr2xenumTestpointSelect DisplayString Size(0..80)
  dualdrr2xvalueTestpointSelect INTEGER
  dualdrr2xstateflagTestpointSelect INTEGER
  dualdrr2xlabelOpFrequency DisplayString Size(0..80)
  dualdrr2xenumOpFrequency DisplayString Size(0..80)
  dualdrr2xvalueOpFrequency INTEGER
  dualdrr2xstateflagOpFrequency INTEGER
  dualdrr2xlabelActChanSelect DisplayString Size(0..80)
  dualdrr2xenumActChanSelect DisplayString Size(0..80)
  dualdrr2xvalueActChanSelect INTEGER
  dualdrr2xstateflagActChanSelect INTEGER
  dualdrr2xlabelFactoryDefaultReset DisplayString Size(0..80)
  dualdrr2xenumFactoryDefaultReset DisplayString Size(0..80)
  dualdrr2xvalueFactoryDefaultReset INTEGER
  dualdrr2xstateflagFactoryDefaultReset INTEGER

Gx2dualdrr2xStatusEntry  
SEQUENCE    
  gx2dualdrr2xStatusTableIndex INTEGER
  dualdrr2xlabelBoot DisplayString Size(0..80)
  dualdrr2xvalueBoot INTEGER
  dualdrr2xstateflagBoot INTEGER
  dualdrr2xlabelFlash DisplayString Size(0..80)
  dualdrr2xvalueFlash INTEGER
  dualdrr2xstateflagFlash INTEGER
  dualdrr2xlabelFactoryDataCRC DisplayString Size(0..80)
  dualdrr2xvalueFactoryDataCRC INTEGER
  dualdrr2xstateflagFactoryDataCRC INTEGER
  dualdrr2xlabelAlarmDataCrc DisplayString Size(0..80)
  dualdrr2xvalueAlarmDataCrc INTEGER
  dualdrr2xstateflagAlarmDataCrc INTEGER
  dualdrr2xlabelCalibrationDataCrc DisplayString Size(0..80)
  dualdrr2xvalueCalibrationDataCrc INTEGER
  dualdrr2xstateflagCalibrationDataCrc INTEGER
  dualdrr2xlabelHardwareStatus DisplayString Size(0..80)
  dualdrr2xvalueHardwareStatus INTEGER
  dualdrr2xstateflagHardwareStatus INTEGER
  dualdrr2xlabelCh1TripPointStatus DisplayString Size(0..80)
  dualdrr2xvalueCh1TripPointStatus INTEGER
  dualdrr2xstateflagCh1TripPointStatus INTEGER
  dualdrr2xlabelLink1Status DisplayString Size(0..80)
  dualdrr2xvalueLink1Status INTEGER
  dualdrr2xstateflagLink1Status INTEGER
  dualdrr2xlabelCh2TripPointStatus DisplayString Size(0..80)
  dualdrr2xvalueCh2TripPointStatus INTEGER
  dualdrr2xstateflagCh2TripPointStatus INTEGER
  dualdrr2xlabelLink2Status DisplayString Size(0..80)
  dualdrr2xvalueLink2Status INTEGER
  dualdrr2xstateflagLink2Status INTEGER
  dualdrr2xlabelDRT1Status DisplayString Size(0..80)
  dualdrr2xvalueDRT1Status INTEGER
  dualdrr2xstateflagDRT1Status INTEGER
  dualdrr2xlabelSFP0Status DisplayString Size(0..80)
  dualdrr2xvalueSFP0Status INTEGER
  dualdrr2xstateflagSFP0Status INTEGER
  dualdrr2xlabelDRT2Status DisplayString Size(0..80)
  dualdrr2xvalueDRT2Status INTEGER
  dualdrr2xstateflagDRT2Status INTEGER
  dualdrr2xlabelSFP1Status DisplayString Size(0..80)
  dualdrr2xvalueSFP1Status INTEGER
  dualdrr2xstateflagSFP1Status INTEGER

Gx2dualdrr2xFactoryEntry  
SEQUENCE    
  gx2dualdrr2xFactoryTableIndex INTEGER
  dualdrr2xbootControlByte INTEGER
  dualdrr2xbootStatusByte INTEGER
  dualdrr2xbank1CRC INTEGER
  dualdrr2xbank2CRC INTEGER
  dualdrr2xprgEEPROMByte INTEGER
  dualdrr2xfactoryCRC INTEGER
  dualdrr2xcalculateCRC INTEGER
  dualdrr2xhourMeter INTEGER
  dualdrr2xflashPrgCntA INTEGER
  dualdrr2xflashPrgCntB INTEGER
  dualdrr2xflashBankARev DisplayString Size(0..80)
  dualdrr2xflashBankBRev DisplayString Size(0..80)
  dualdrr2xSubAgentRev DisplayString Size(0..80)
  dualdrr2xFPGA0FwRev DisplayString Size(0..80)
  dualdrr2xFPGA1FwRev DisplayString Size(0..80)
  dualdrr2xDRT1SerialNo DisplayString Size(0..80)
  dualdrr2xDRT1FwRev DisplayString Size(0..80)
  dualdrr2xDRT1FpgaFwRev DisplayString Size(0..80)
  dualdrr2xDRT1SFPSerialNo DisplayString Size(0..80)
  dualdrr2xDRT1SFPPartNo DisplayString Size(0..80)
  dualdrr2xDRT2SerialNo DisplayString Size(0..80)
  dualdrr2xDRT2FwRev DisplayString Size(0..80)
  dualdrr2xDRT2FpgaFwRev DisplayString Size(0..80)
  dualdrr2xDRT2SFPSerialNo DisplayString Size(0..80)
  dualdrr2xDRT2SFPPartNo DisplayString Size(0..80)

Defined Values

gx2dualdrr2xDescriptor 1.3.6.1.4.1.1166.6.1.2.35.1
OBJECT IDENTIFIER    

gx2dualdrr2xAnalogTable 1.3.6.1.4.1.1166.6.1.2.35.2
This table contains gx2dualdrr2x specific analog parameters with nominal,limits and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2dualdrr2xAnalogEntry

gx2dualdrr2xAnalogEntry 1.3.6.1.4.1.1166.6.1.2.35.2.1
This list contains the analog parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2dualdrr2xAnalogEntry  

gx2dualdrr2xDigitalTable 1.3.6.1.4.1.1166.6.1.2.35.3
This table contains gx2dualdrr2x specific digital parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2dualdrr2xDigitalEntry

gx2dualdrr2xDigitalEntry 1.3.6.1.4.1.1166.6.1.2.35.3.2
This list contains individual digital parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2dualdrr2xDigitalEntry  

gx2dualdrr2xStatusTable 1.3.6.1.4.1.1166.6.1.2.35.4
This table contains gx2dualdrr2x specific status parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2dualdrr2xStatusEntry

gx2dualdrr2xStatusEntry 1.3.6.1.4.1.1166.6.1.2.35.4.3
This list contains Status parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2dualdrr2xStatusEntry  

gx2dualdrr2xFactoryTable 1.3.6.1.4.1.1166.6.1.2.35.5
This table contains gx2dualdrr2x specific factory setting parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2dualdrr2xFactoryEntry

gx2dualdrr2xFactoryEntry 1.3.6.1.4.1.1166.6.1.2.35.5.4
This list contains Factory setting parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2dualdrr2xFactoryEntry  

gx2dualdrr2xAnalogTableIndex 1.3.6.1.4.1.1166.6.1.2.35.2.1.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

dualdrr2xlabelRecdOptPwr1 1.3.6.1.4.1.1166.6.1.2.35.2.1.2
The value of this object provides the label of the Channel 1 Received Opt power Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xuomRecdOptPwr1 1.3.6.1.4.1.1166.6.1.2.35.2.1.3
The value of this object provides the Unit of Measure of the Channel 1 Received Opt power Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xmajorHighRecdOptPwr1 1.3.6.1.4.1.1166.6.1.2.35.2.1.4
This object is not used by this module and always returns the value of the Channel 1 Received Opt power Major High Alarm Limit Analog parameter.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xmajorLowRecdOptPwr1 1.3.6.1.4.1.1166.6.1.2.35.2.1.5
This object is not used by this module and always returns the value of the Channel 1 Received Opt power Major High Alarm Limit Analog parameter.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xminorHighRecdOptPwr1 1.3.6.1.4.1.1166.6.1.2.35.2.1.6
This object is not used by this module and always returns the value of 10^e10 . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xminorLowRecdOptPwr1 1.3.6.1.4.1.1166.6.1.2.35.2.1.7
This object is not used by this module and always returns the value of 10^e10 . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xcurrentValueRecdOptPwr1 1.3.6.1.4.1.1166.6.1.2.35.2.1.8
The value of this object provides the Current value of the Channel 1 Received Opt power.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Float  

dualdrr2xstateFlagRecdOptPwr1 1.3.6.1.4.1.1166.6.1.2.35.2.1.9
The value of this object provides the state of the Channel 1 Received Opt power Analog parameter. (1-hidden 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dualdrr2xminValueRecdOptPwr1 1.3.6.1.4.1.1166.6.1.2.35.2.1.10
The value of this object provides the minimum value of the Channel 1 Received Opt power.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xmaxValueRecdOptPwr1 1.3.6.1.4.1.1166.6.1.2.35.2.1.11
The value of this object provides the maximum value of the Channel 1 Received Opt power.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xalarmStateRecdOptPwr1 1.3.6.1.4.1.1166.6.1.2.35.2.1.12
The value of this object provides the curent alarm state of the Channel 1 Received Opt power.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

dualdrr2xlabelRecdOptPwr2 1.3.6.1.4.1.1166.6.1.2.35.2.1.13
The value of this object provides the label of the Channel 2 Received Opt power Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xuomRecdOptPwr2 1.3.6.1.4.1.1166.6.1.2.35.2.1.14
The value of this object provides the Unit of Measure of the Channel 2 Received Opt power Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xmajorHighRecdOptPwr2 1.3.6.1.4.1.1166.6.1.2.35.2.1.15
This object is not used by this module and always returns the value of the Channel 2 Received Opt power Major High Alarm Limit Analog parameter.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xmajorLowRecdOptPwr2 1.3.6.1.4.1.1166.6.1.2.35.2.1.16
This object is not used by this module and always returns the value of the Channel 2 Received Opt power Major High Alarm Limit Analog parameter.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xminorHighRecdOptPwr2 1.3.6.1.4.1.1166.6.1.2.35.2.1.17
This object is not used by this module and always returns the value of 10^e10 . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xminorLowRecdOptPwr2 1.3.6.1.4.1.1166.6.1.2.35.2.1.18
This object is not used by this module and always returns the value of 10^e10 . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xcurrentValueRecdOptPwr2 1.3.6.1.4.1.1166.6.1.2.35.2.1.19
The value of this object provides the Current value of the Channel 2 Received Opt power.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Float  

dualdrr2xstateFlagRecdOptPwr2 1.3.6.1.4.1.1166.6.1.2.35.2.1.20
The value of this object provides the state of the Channel 2 Received Opt power Analog parameter. (1-hidden 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dualdrr2xminValueRecdOptPwr2 1.3.6.1.4.1.1166.6.1.2.35.2.1.21
The value of this object provides the minimum value of the Channel 2 Received Opt power.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xmaxValueRecdOptPwr2 1.3.6.1.4.1.1166.6.1.2.35.2.1.22
The value of this object provides the maximum value of the Channel 2 Received Opt power.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xalarmStateRecdOptPwr2 1.3.6.1.4.1.1166.6.1.2.35.2.1.23
The value of this object provides the curent alarm state of the Channel 2 Received optical power.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

dualdrr2xlabelModTemp 1.3.6.1.4.1.1166.6.1.2.35.2.1.24
The value of this object provides the label of the Module Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xuomModTemp 1.3.6.1.4.1.1166.6.1.2.35.2.1.25
The value of this object provides the Unit of Measure of the Module Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xmajorHighModTemp 1.3.6.1.4.1.1166.6.1.2.35.2.1.26
The value of this object provides the Major High alarm value of the Module Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xmajorLowModTemp 1.3.6.1.4.1.1166.6.1.2.35.2.1.27
The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xminorHighModTemp 1.3.6.1.4.1.1166.6.1.2.35.2.1.28
The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xminorLowModTemp 1.3.6.1.4.1.1166.6.1.2.35.2.1.29
The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xcurrentValueModTemp 1.3.6.1.4.1.1166.6.1.2.35.2.1.30
The value of this object provides the Current value of the Module Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xstateFlagModTemp 1.3.6.1.4.1.1166.6.1.2.35.2.1.31
The value of this object provides the state of the Module Temperature Analog parameter. (1-hidden 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dualdrr2xminValueModTemp 1.3.6.1.4.1.1166.6.1.2.35.2.1.32
The value of this object provides the minimum value the Module Temperature Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xmaxValueModTemp 1.3.6.1.4.1.1166.6.1.2.35.2.1.33
The value of this object provides the maximum value the Module Temperature Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xalarmStateModTemp 1.3.6.1.4.1.1166.6.1.2.35.2.1.34
The value of this object provides the curent alarm state of the Module Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

dualdrr2xlabel12VCurrent 1.3.6.1.4.1.1166.6.1.2.35.2.1.35
The value of this object provides the label of the 12v power supply Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xuom12VCurrent 1.3.6.1.4.1.1166.6.1.2.35.2.1.36
The value of this object provides the Unit of Measure of the 12v power supply Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xmajorHigh12VCurrent 1.3.6.1.4.1.1166.6.1.2.35.2.1.37
The value of this object provides the Major High alarm value of the 12v power supply Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xmajorLow12VCurrent 1.3.6.1.4.1.1166.6.1.2.35.2.1.38
The value of this object provides the Major Low alarm value of the 12v power supply Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xminorHigh12VCurrent 1.3.6.1.4.1.1166.6.1.2.35.2.1.39
The value of this object provides the Minor High alarm value of the 12v power supply Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xminorLow12VCurrent 1.3.6.1.4.1.1166.6.1.2.35.2.1.40
The value of this object provides the Minor Low alarm value of the 12v power supply Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xcurrentValue12VCurrent 1.3.6.1.4.1.1166.6.1.2.35.2.1.41
The value of this object provides the Current value of the 12v power supply Current parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xstateFlag12VCurrent 1.3.6.1.4.1.1166.6.1.2.35.2.1.42
The value of this object provides the state of the 12v power supply Current Analog parameter. (1-hidden 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dualdrr2xminValue12VCurrent 1.3.6.1.4.1.1166.6.1.2.35.2.1.43
The value of this object provides the minimum value the 12v power supply Current Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xmaxValue12VCurrent 1.3.6.1.4.1.1166.6.1.2.35.2.1.44
The value of this object provides the maximum value the 12v power supply Current Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xalarmState12VCurrent 1.3.6.1.4.1.1166.6.1.2.35.2.1.45
The value of this object provides the curent alarm state of the 12v power supply Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

dualdrr2xlabelFanSpeed 1.3.6.1.4.1.1166.6.1.2.35.2.1.46
The value of this object provides the label of the Fan Speed Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xuomFanSpeed 1.3.6.1.4.1.1166.6.1.2.35.2.1.47
The value of this object provides the Unit of Measure of the Fan Speed Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xmajorHighFanSpeed 1.3.6.1.4.1.1166.6.1.2.35.2.1.48
The value of this object provides the Major High alarm value of the Fan Speed Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xmajorLowFanSpeed 1.3.6.1.4.1.1166.6.1.2.35.2.1.49
The value of this object provides the Major Low alarm value of the Fan Speed Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xminorHighFanSpeed 1.3.6.1.4.1.1166.6.1.2.35.2.1.50
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xminorLowFanSpeed 1.3.6.1.4.1.1166.6.1.2.35.2.1.51
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xcurrentValueFanSpeed 1.3.6.1.4.1.1166.6.1.2.35.2.1.52
The value of this object provides the current value of the Fan Speed Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xstateFlagFanSpeed 1.3.6.1.4.1.1166.6.1.2.35.2.1.53
The value of this object provides the state of the Fan Speed Analog parameter. (1-hidden 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dualdrr2xminValueFanSpeed 1.3.6.1.4.1.1166.6.1.2.35.2.1.54
The value of this object provides the minimum value the Fan Speed Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xmaxValueFanSpeed 1.3.6.1.4.1.1166.6.1.2.35.2.1.55
The value of this object provides the maximum value the Fan Speed Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xalarmStateFanSpeed 1.3.6.1.4.1.1166.6.1.2.35.2.1.56
The value of this object provides the curent alarm state of the Fan Speed Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

dualdrr2xlabelTx0SFPWave 1.3.6.1.4.1.1166.6.1.2.35.2.1.57
The value of this object provides the label of the Tx 0 SFP Wavelength Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xuomTx0SFPWave 1.3.6.1.4.1.1166.6.1.2.35.2.1.58
The value of this object provides the Unit of Measure of the Tx 0 SFP Wavelength Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xmajorHighTx0SFPWave 1.3.6.1.4.1.1166.6.1.2.35.2.1.59
The value of this object provides the Major High alarm value of the Tx 0 SFP Wavelength Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xmajorLowTx0SFPWave 1.3.6.1.4.1.1166.6.1.2.35.2.1.60
The value of this object provides the Major Low alarm value of the Tx 0 SFP Wavelength Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xminorHighTx0SFPWave 1.3.6.1.4.1.1166.6.1.2.35.2.1.61
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xminorLowTx0SFPWave 1.3.6.1.4.1.1166.6.1.2.35.2.1.62
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xcurrentValueTx0SFPWave 1.3.6.1.4.1.1166.6.1.2.35.2.1.63
The value of this object provides the current value of the Tx 0 SFP Wavelength Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xstateFlagTx0SFPWave 1.3.6.1.4.1.1166.6.1.2.35.2.1.64
The value of this object provides the state of the Tx 0 SFP Wavelength Analog parameter. (1-hidden 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dualdrr2xminValueTx0SFPWave 1.3.6.1.4.1.1166.6.1.2.35.2.1.65
The value of this object provides the minimum value the Tx 0 SFP Wavelength Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xmaxValueTx0SFPWave 1.3.6.1.4.1.1166.6.1.2.35.2.1.66
The value of this object provides the maximum value the Tx 0 SFP Wavelength Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xalarmStateTx0SFPWave 1.3.6.1.4.1.1166.6.1.2.35.2.1.67
The value of this object provides the curent alarm state of the Tx 0 SFP Wavelength Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

dualdrr2xlabelTx0OptPwr 1.3.6.1.4.1.1166.6.1.2.35.2.1.68
The value of this object provides the label of the Tx 0 Optical Power Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xuomTx0OptPwr 1.3.6.1.4.1.1166.6.1.2.35.2.1.69
The value of this object provides the Unit of Measure of the Tx 0 Optical Power Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xmajorHighTx0OptPwr 1.3.6.1.4.1.1166.6.1.2.35.2.1.70
The value of this object provides the Major High alarm value of the Tx 0 Optical Power Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xmajorLowTx0OptPwr 1.3.6.1.4.1.1166.6.1.2.35.2.1.71
The value of this object provides the Major Low alarm value of the Tx 0 Optical Power Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xminorHighTx0OptPwr 1.3.6.1.4.1.1166.6.1.2.35.2.1.72
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xminorLowTx0OptPwr 1.3.6.1.4.1.1166.6.1.2.35.2.1.73
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xcurrentValueTx0OptPwr 1.3.6.1.4.1.1166.6.1.2.35.2.1.74
The value of this object provides the current value of the Tx 0 Optical Power Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xstateFlagTx0OptPwr 1.3.6.1.4.1.1166.6.1.2.35.2.1.75
The value of this object provides the state of the Tx 0 Optical Power Analog parameter. (1-hidden 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dualdrr2xminValueTx0OptPwr 1.3.6.1.4.1.1166.6.1.2.35.2.1.76
The value of this object provides the minimum value the Tx 0 Optical Power Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xmaxValueTx0OptPwr 1.3.6.1.4.1.1166.6.1.2.35.2.1.77
The value of this object provides the maximum value the Tx 0 Optical Power Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xalarmStateTx0OptPwr 1.3.6.1.4.1.1166.6.1.2.35.2.1.78
The value of this object provides the curent alarm state of the Tx 0 Optical Power Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

dualdrr2xlabelTx024vCurr 1.3.6.1.4.1.1166.6.1.2.35.2.1.79
The value of this object provides the label of the Tx 0 24 Volt Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xuomTx024vCurr 1.3.6.1.4.1.1166.6.1.2.35.2.1.80
The value of this object provides the Unit of Measure of the Tx 0 24 Volt Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xmajorHighTx024vCurr 1.3.6.1.4.1.1166.6.1.2.35.2.1.81
The value of this object provides the Major High alarm value of the Tx 0 24 Volt Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xmajorLowTx024vCurr 1.3.6.1.4.1.1166.6.1.2.35.2.1.82
The value of this object provides the Major Low alarm value of the Tx 0 24 Volt Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xminorHighTx024vCurr 1.3.6.1.4.1.1166.6.1.2.35.2.1.83
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xminorLowTx024vCurr 1.3.6.1.4.1.1166.6.1.2.35.2.1.84
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xcurrentValueTx024vCurr 1.3.6.1.4.1.1166.6.1.2.35.2.1.85
The value of this object provides the current value of the Tx 0 24 Volt Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xstateFlagTx024vCurr 1.3.6.1.4.1.1166.6.1.2.35.2.1.86
The value of this object provides the state of the Tx 0 24 Volt Current Analog parameter. (1-hidden 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dualdrr2xminValueTx024vCurr 1.3.6.1.4.1.1166.6.1.2.35.2.1.87
The value of this object provides the minimum value the Tx 0 24 Volt Current Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xmaxValueTx024vCurr 1.3.6.1.4.1.1166.6.1.2.35.2.1.88
The value of this object provides the maximum value the Tx 0 24 Volt Current Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xalarmStateTx024vCurr 1.3.6.1.4.1.1166.6.1.2.35.2.1.89
The value of this object provides the curent alarm state of the Tx 0 24 Volt Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

dualdrr2xlabelTx024Volt 1.3.6.1.4.1.1166.6.1.2.35.2.1.90
The value of this object provides the label of the Tx 0 24 Volt supply voltage Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xuomTx024Volt 1.3.6.1.4.1.1166.6.1.2.35.2.1.91
The value of this object provides the Unit of Measure of the Tx 0 24 Volt supply voltage Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xmajorHighTx024Volt 1.3.6.1.4.1.1166.6.1.2.35.2.1.92
The value of this object provides the Major High alarm value of the Tx 0 24 Volt supply voltage Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xmajorLowTx024Volt 1.3.6.1.4.1.1166.6.1.2.35.2.1.93
The value of this object provides the Major Low alarm value of the Tx 0 24 Volt supply voltage Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xminorHighTx024Volt 1.3.6.1.4.1.1166.6.1.2.35.2.1.94
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xminorLowTx024Volt 1.3.6.1.4.1.1166.6.1.2.35.2.1.95
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xcurrentValueTx024Volt 1.3.6.1.4.1.1166.6.1.2.35.2.1.96
The value of this object provides the current value of the Tx 0 24 Volt supply voltage Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xstateFlagTx024Volt 1.3.6.1.4.1.1166.6.1.2.35.2.1.97
The value of this object provides the state of the Tx 0 24 Volt supply voltage Analog parameter. (1-hidden 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dualdrr2xminValueTx024Volt 1.3.6.1.4.1.1166.6.1.2.35.2.1.98
The value of this object provides the minimum value the Tx 0 24 Volt supply voltage Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xmaxValueTx024Volt 1.3.6.1.4.1.1166.6.1.2.35.2.1.99
The value of this object provides the maximum value the Tx 0 24 Volt supply voltage Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xalarmStateTx024Volt 1.3.6.1.4.1.1166.6.1.2.35.2.1.100
The value of this object provides the curent alarm state of the Tx 0 24 Volt supply voltage Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

dualdrr2xlabelTx0ModTemp 1.3.6.1.4.1.1166.6.1.2.35.2.1.101
The value of this object provides the label of the Tx 0 24 Module Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xuomTx0ModTemp 1.3.6.1.4.1.1166.6.1.2.35.2.1.102
The value of this object provides the Unit of Measure of the Tx 0 Module Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xmajorHighTx0ModTemp 1.3.6.1.4.1.1166.6.1.2.35.2.1.103
The value of this object provides the Major High alarm value of the Tx 0 Module Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xmajorLowTx0ModTemp 1.3.6.1.4.1.1166.6.1.2.35.2.1.104
The value of this object provides the Major Low alarm value of the Tx 0 Module Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xminorHighTx0ModTemp 1.3.6.1.4.1.1166.6.1.2.35.2.1.105
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xminorLowTx0ModTemp 1.3.6.1.4.1.1166.6.1.2.35.2.1.106
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xcurrentValueTx0ModTemp 1.3.6.1.4.1.1166.6.1.2.35.2.1.107
The value of this object provides the current value of the Tx 0 Module Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xstateFlagTx0ModTemp 1.3.6.1.4.1.1166.6.1.2.35.2.1.108
The value of this object provides the state of the Tx 0 Module Temperature Analog parameter. (1-hidden 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dualdrr2xminValueTx0ModTemp 1.3.6.1.4.1.1166.6.1.2.35.2.1.109
The value of this object provides the minimum value the Tx 0 Module Temperature Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xmaxValueTx0ModTemp 1.3.6.1.4.1.1166.6.1.2.35.2.1.110
The value of this object provides the maximum value the Tx 0 Module Temperature Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xalarmStateTx0ModTemp 1.3.6.1.4.1.1166.6.1.2.35.2.1.111
The value of this object provides the curent alarm state of the Tx 0 Module Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

dualdrr2xlabelTx1SFPWave 1.3.6.1.4.1.1166.6.1.2.35.2.1.112
The value of this object provides the label of the Tx 1 SFP Wavelength Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xuomTx1SFPWave 1.3.6.1.4.1.1166.6.1.2.35.2.1.113
The value of this object provides the Unit of Measure of the Tx 1 SFP Wavelength Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xmajorHighTx1SFPWave 1.3.6.1.4.1.1166.6.1.2.35.2.1.114
The value of this object provides the Major High alarm value of the Tx 1 SFP Wavelength Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xmajorLowTx1SFPWave 1.3.6.1.4.1.1166.6.1.2.35.2.1.115
The value of this object provides the Major Low alarm value of the Tx 1 SFP Wavelength Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xminorHighTx1SFPWave 1.3.6.1.4.1.1166.6.1.2.35.2.1.116
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xminorLowTx1SFPWave 1.3.6.1.4.1.1166.6.1.2.35.2.1.117
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xcurrentValueTx1SFPWave 1.3.6.1.4.1.1166.6.1.2.35.2.1.118
The value of this object provides the current value of the Tx 1 SFP Wavelength Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xstateFlagTx1SFPWave 1.3.6.1.4.1.1166.6.1.2.35.2.1.119
The value of this object provides the state of the Tx 1 SFP Wavelength Analog parameter. (1-hidden 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dualdrr2xminValueTx1SFPWave 1.3.6.1.4.1.1166.6.1.2.35.2.1.120
The value of this object provides the minimum value the Tx 1 SFP Wavelength Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xmaxValueTx1SFPWave 1.3.6.1.4.1.1166.6.1.2.35.2.1.121
The value of this object provides the maximum value the Tx 1 SFP Wavelength Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xalarmStateTx1SFPWave 1.3.6.1.4.1.1166.6.1.2.35.2.1.122
The value of this object provides the curent alarm state of the Tx 1 SFP Wavelength Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

dualdrr2xlabelTx1OptPwr 1.3.6.1.4.1.1166.6.1.2.35.2.1.123
The value of this object provides the label of the Tx 1 Optical Power Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xuomTx1OptPwr 1.3.6.1.4.1.1166.6.1.2.35.2.1.124
The value of this object provides the Unit of Measure of the Tx 1 Optical Power Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xmajorHighTx1OptPwr 1.3.6.1.4.1.1166.6.1.2.35.2.1.125
The value of this object provides the Major High alarm value of the Tx 1 Optical Power Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xmajorLowTx1OptPwr 1.3.6.1.4.1.1166.6.1.2.35.2.1.126
The value of this object provides the Major Low alarm value of the Tx 1 Optical Power Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xminorHighTx1OptPwr 1.3.6.1.4.1.1166.6.1.2.35.2.1.127
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xminorLowTx1OptPwr 1.3.6.1.4.1.1166.6.1.2.35.2.1.128
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xcurrentValueTx1OptPwr 1.3.6.1.4.1.1166.6.1.2.35.2.1.129
The value of this object provides the current value of the Tx 1 Optical Power Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xstateFlagTx1OptPwr 1.3.6.1.4.1.1166.6.1.2.35.2.1.130
The value of this object provides the state of the Tx 1 Optical Power Analog parameter. (1-hidden 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dualdrr2xminValueTx1OptPwr 1.3.6.1.4.1.1166.6.1.2.35.2.1.131
The value of this object provides the minimum value the Tx 1 Optical Power Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xmaxValueTx1OptPwr 1.3.6.1.4.1.1166.6.1.2.35.2.1.132
The value of this object provides the maximum value the Tx 1 Optical Power Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xalarmStateTx1OptPwr 1.3.6.1.4.1.1166.6.1.2.35.2.1.133
The value of this object provides the curent alarm state of the Tx 1 Optical Power Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

dualdrr2xlabelTx124vCurr 1.3.6.1.4.1.1166.6.1.2.35.2.1.134
The value of this object provides the label of the Tx 1 24 VoltCurrent Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xuomTx124vCurr 1.3.6.1.4.1.1166.6.1.2.35.2.1.135
The value of this object provides the Unit of Measure of the Tx 1 24 Volt Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xmajorHighTx124vCurr 1.3.6.1.4.1.1166.6.1.2.35.2.1.136
The value of this object provides the Major High alarm value of the Tx 1 24 Volt Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xmajorLowTx124vCurr 1.3.6.1.4.1.1166.6.1.2.35.2.1.137
The value of this object provides the Major Low alarm value of the Tx 1 24 Volt Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xminorHighTx124vCurr 1.3.6.1.4.1.1166.6.1.2.35.2.1.138
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xminorLowTx124vCurr 1.3.6.1.4.1.1166.6.1.2.35.2.1.139
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xcurrentValueTx124vCurr 1.3.6.1.4.1.1166.6.1.2.35.2.1.140
The value of this object provides the current value of the Tx 1 24 Volt Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xstateFlagTx124vCurr 1.3.6.1.4.1.1166.6.1.2.35.2.1.141
The value of this object provides the state of the Tx 1 24 Volt Current Analog parameter. (1-hidden 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dualdrr2xminValueTx124vCurr 1.3.6.1.4.1.1166.6.1.2.35.2.1.142
The value of this object provides the minimum value the Tx 1 24 Volt Current Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xmaxValueTx124vCurr 1.3.6.1.4.1.1166.6.1.2.35.2.1.143
The value of this object provides the maximum value the Tx 1 24 Volt Current Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xalarmStateTx124vCurr 1.3.6.1.4.1.1166.6.1.2.35.2.1.144
The value of this object provides the curent alarm state of the Tx 1 24 Volt Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

dualdrr2xlabelTx124Volt 1.3.6.1.4.1.1166.6.1.2.35.2.1.145
The value of this object provides the label of the Tx 1 24 Volt supply voltage Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xuomTx124Volt 1.3.6.1.4.1.1166.6.1.2.35.2.1.146
The value of this object provides the Unit of Measure of the Tx 1 24 Volt supply voltage Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xmajorHighTx124Volt 1.3.6.1.4.1.1166.6.1.2.35.2.1.147
The value of this object provides the Major High alarm value of the Tx 1 24 Volt supply voltage Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xmajorLowTx124Volt 1.3.6.1.4.1.1166.6.1.2.35.2.1.148
The value of this object provides the Major Low alarm value of the Tx 1 24 Volt supply voltage Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xminorHighTx124Volt 1.3.6.1.4.1.1166.6.1.2.35.2.1.149
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xminorLowTx124Volt 1.3.6.1.4.1.1166.6.1.2.35.2.1.150
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xcurrentValueTx124Volt 1.3.6.1.4.1.1166.6.1.2.35.2.1.151
The value of this object provides the current value of the Tx 1 24 Volt supply voltage Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xstateFlagTx124Volt 1.3.6.1.4.1.1166.6.1.2.35.2.1.152
The value of this object provides the state of the Tx 1 24 Volt supply voltage Analog parameter. (1-hidden 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dualdrr2xminValueTx124Volt 1.3.6.1.4.1.1166.6.1.2.35.2.1.153
The value of this object provides the minimum value the Tx 1 24 Volt supply voltage Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xmaxValueTx124Volt 1.3.6.1.4.1.1166.6.1.2.35.2.1.154
The value of this object provides the maximum value the Tx 1 24 Volt supply voltage Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xalarmStateTx124Volt 1.3.6.1.4.1.1166.6.1.2.35.2.1.155
The value of this object provides the curent alarm state of the Tx 1 24 Volt supply voltage Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

dualdrr2xlabelTx1ModTemp 1.3.6.1.4.1.1166.6.1.2.35.2.1.156
The value of this object provides the label of the Tx 1 24 Module Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xuomTx1ModTemp 1.3.6.1.4.1.1166.6.1.2.35.2.1.157
The value of this object provides the Unit of Measure of the Tx 1 Module Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xmajorHighTx1ModTemp 1.3.6.1.4.1.1166.6.1.2.35.2.1.158
The value of this object provides the Major High alarm value of the Tx 1 Module Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xmajorLowTx1ModTemp 1.3.6.1.4.1.1166.6.1.2.35.2.1.159
The value of this object provides the Major Low alarm value of the Tx 1 Module Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xminorHighTx1ModTemp 1.3.6.1.4.1.1166.6.1.2.35.2.1.160
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xminorLowTx1ModTemp 1.3.6.1.4.1.1166.6.1.2.35.2.1.161
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xcurrentValueTx1ModTemp 1.3.6.1.4.1.1166.6.1.2.35.2.1.162
The value of this object provides the current value of the Tx 1 Module Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xstateFlagTx1ModTemp 1.3.6.1.4.1.1166.6.1.2.35.2.1.163
The value of this object provides the state of the Tx 1 Module Temperature Analog parameter. (1-hidden 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dualdrr2xminValueTx1ModTemp 1.3.6.1.4.1.1166.6.1.2.35.2.1.164
The value of this object provides the minimum value the Tx 1 Module Temperature Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xmaxValueTx1ModTemp 1.3.6.1.4.1.1166.6.1.2.35.2.1.165
The value of this object provides the maximum value the Tx 1 Module Temperature Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

dualdrr2xalarmStateTx1ModTemp 1.3.6.1.4.1.1166.6.1.2.35.2.1.166
The value of this object provides the curent alarm state of the Tx 1 Module Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

gx2dualdrr2xDigitalTableIndex 1.3.6.1.4.1.1166.6.1.2.35.3.2.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

dualdrr2xlabelTrippoint1Value 1.3.6.1.4.1.1166.6.1.2.35.3.2.2
The value of this object provides the label of the Trip point Value Digital parameter. The trip point Value defines the RF switch point based on the optical power input to the DRR
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xenumTrippoint1Value 1.3.6.1.4.1.1166.6.1.2.35.3.2.3
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xvalueTrippoint1Value 1.3.6.1.4.1.1166.6.1.2.35.3.2.4
The value of this object reflects the setting of the threshold at which the Trip point activates. It is in 1 dB increments ranging from -25 to -5 dB. The user can enter a number from 0 to 20, where 0 = -5db and 19 = -25db
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

dualdrr2xstateflagTrippoint1Value 1.3.6.1.4.1.1166.6.1.2.35.3.2.5
The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), readOnly(2), updateable(3)  

dualdrr2xlabelTrippoint1Mode 1.3.6.1.4.1.1166.6.1.2.35.3.2.6
The value of this object provides the label of the Trip point mode Digital parameter. The trip point mode defines the RF switch action based on the optical power input to the DRR
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xenumTrippoint1Mode 1.3.6.1.4.1.1166.6.1.2.35.3.2.7
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xvalueTrippoint1Mode 1.3.6.1.4.1.1166.6.1.2.35.3.2.8
The value of this object is the current value of trip point mode. There are three possible value: 1-off, 2-alarm_only, 3-alarm&switch. If module input optical power is higher than the preset trippoint value, no operational difference for these three modes. If module input optical power is less than the preset trippoint value, 1) When trippoint mode is OFF, no trippoint alarm will be generated and RF output impedance will stay normal as low. 2) When tripoint mode is ALARM_ONLY, trip_point alarm will be generated when the input optical power lower than the preset trippoint level but RF output impedance will stay normal as low. 3) When trippoint mode is ALARM_SWITCH, trip point alarm will be generated and RF output impedance will switch to abnorml
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), alarmOnly(2), alarm-and-Switch(3)  

dualdrr2xstateflagTrippoint1Mode 1.3.6.1.4.1.1166.6.1.2.35.3.2.9
The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), readOnly(2), updateable(3)  

dualdrr2xlabelTrippoint2Value 1.3.6.1.4.1.1166.6.1.2.35.3.2.10
The value of this object provides the label of the Trip point Value Digital parameter. The trip point Value defines the RF switch point based on the optical power input to the DRR
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xenumTrippoint2Value 1.3.6.1.4.1.1166.6.1.2.35.3.2.11
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xvalueTrippoint2Value 1.3.6.1.4.1.1166.6.1.2.35.3.2.12
The value of this object reflects the setting of the threshold at which the Trip point activates. It is in 1 dB increments ranging from -25 to -5 dB. The user can enter a number from 0 to 20, where 0 = -5db and 19 = -25db
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

dualdrr2xstateflagTrippoint2Value 1.3.6.1.4.1.1166.6.1.2.35.3.2.13
The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), readOnly(2), updateable(3)  

dualdrr2xlabelTrippoint2Mode 1.3.6.1.4.1.1166.6.1.2.35.3.2.14
The value of this object provides the label of the Trip point mode Digital parameter. The trip point mode defines the RF switch action based on the optical power input to the DRR
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xenumTrippoint2Mode 1.3.6.1.4.1.1166.6.1.2.35.3.2.15
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xvalueTrippoint2Mode 1.3.6.1.4.1.1166.6.1.2.35.3.2.16
The value of this object is the current value of trip point mode. There are three possible value: 1-off, 2-alarm_only, 3-alarm&switch. If module input optical power is higher than the preset trippoint value, no operational difference for these three modes. If module input optical power is less than the preset trippoint value, 1) When trippoint mode is OFF, no trippoint alarm will be generated and RF output impedance will stay normal as low. 2) When tripoint mode is ALARM_ONLY, trip_point alarm will be generated when the input optical power lower than the preset trippoint level but RF output impedance will stay normal as low. 3) When trippoint mode is ALARM_SWITCH, trip point alarm will be generated and RF output impedance will switch to abnorml
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), alarmOnly(2), alarm-and-Switch(3)  

dualdrr2xstateflagTrippoint2Mode 1.3.6.1.4.1.1166.6.1.2.35.3.2.17
The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), readOnly(2), updateable(3)  

dualdrr2xlabelGainChannel1A 1.3.6.1.4.1.1166.6.1.2.35.3.2.18
The value of this object provides the label of the RF Channel 1A Gain Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xenumGainChannel1A 1.3.6.1.4.1.1166.6.1.2.35.3.2.19
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xvalueGainChannel1A 1.3.6.1.4.1.1166.6.1.2.35.3.2.20
The value of this object reflects the setting of the gain for RF Channel 1A. It is in 1 dB increments ranging from 0 to 20dB. The user can enter a number from 0 to 20
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

dualdrr2xstateflagGainChannel1A 1.3.6.1.4.1.1166.6.1.2.35.3.2.21
The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), readOnly(2), updateable(3)  

dualdrr2xlabelGainChannel1B 1.3.6.1.4.1.1166.6.1.2.35.3.2.22
The value of this object provides the label of the RF Channel 1B Gain Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xenumGainChannel1B 1.3.6.1.4.1.1166.6.1.2.35.3.2.23
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xvalueGainChannel1B 1.3.6.1.4.1.1166.6.1.2.35.3.2.24
The value of this object reflects the setting of the gain for RF Channel 1B. It is in 1 dB increments ranging from 0 to 20dB. The user can enter a number from 0 to 20
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

dualdrr2xstateflagGainChannel1B 1.3.6.1.4.1.1166.6.1.2.35.3.2.25
The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), readOnly(2), updateable(3)  

dualdrr2xlabelGainChannel2A 1.3.6.1.4.1.1166.6.1.2.35.3.2.26
The value of this object provides the label of the RF Channel 2A Gain Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xenumGainChannel2A 1.3.6.1.4.1.1166.6.1.2.35.3.2.27
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xvalueGainChannel2A 1.3.6.1.4.1.1166.6.1.2.35.3.2.28
The value of this object reflects the setting of the gain for RF Channel 2A. It is in 1 dB increments ranging from 0 to 20dB. The user can enter a number from 0 to 20
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

dualdrr2xstateflagGainChannel2A 1.3.6.1.4.1.1166.6.1.2.35.3.2.29
The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), readOnly(2), updateable(3)  

dualdrr2xlabelGainChannel2B 1.3.6.1.4.1.1166.6.1.2.35.3.2.30
The value of this object provides the label of the RF Channel 2B Gain Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xenumGainChannel2B 1.3.6.1.4.1.1166.6.1.2.35.3.2.31
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xvalueGainChannel2B 1.3.6.1.4.1.1166.6.1.2.35.3.2.32
The value of this object reflects the setting of the gain for RF Channel 2B. It is in 1 dB increments ranging from 0 to 20dB. The user can enter a number from 0 to 20
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

dualdrr2xstateflagGainChannel2B 1.3.6.1.4.1.1166.6.1.2.35.3.2.33
The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), readOnly(2), updateable(3)  

dualdrr2xlabelTestpointSelect 1.3.6.1.4.1.1166.6.1.2.35.3.2.34
The value of this object provides the label of the Module's test point select Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xenumTestpointSelect 1.3.6.1.4.1.1166.6.1.2.35.3.2.35
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xvalueTestpointSelect 1.3.6.1.4.1.1166.6.1.2.35.3.2.36
The value of this object reflects the setting of the test point selector for The Module. The user can enter a number from 1 to 4
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER one(1), two(2), three(3), four(4)  

dualdrr2xstateflagTestpointSelect 1.3.6.1.4.1.1166.6.1.2.35.3.2.37
The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), readOnly(2), updateable(3)  

dualdrr2xlabelOpFrequency 1.3.6.1.4.1.1166.6.1.2.35.3.2.38
The value of this object provides the label of the Module's active channels Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xenumOpFrequency 1.3.6.1.4.1.1166.6.1.2.35.3.2.39
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xvalueOpFrequency 1.3.6.1.4.1.1166.6.1.2.35.3.2.40
The value of this object reflects which channels are active for The Module. The user can enter a number from 1 to 4
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER eightyfive(1), sixtyfive(2)  

dualdrr2xstateflagOpFrequency 1.3.6.1.4.1.1166.6.1.2.35.3.2.41
The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), readOnly(2), updateable(3)  

dualdrr2xlabelActChanSelect 1.3.6.1.4.1.1166.6.1.2.35.3.2.42
The value of this object provides the label of the Module's active channels Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xenumActChanSelect 1.3.6.1.4.1.1166.6.1.2.35.3.2.43
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xvalueActChanSelect 1.3.6.1.4.1.1166.6.1.2.35.3.2.44
The value of this object reflects which channels are active for The Module. The user can enter a number from 1 to 4
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), channel1(2), channel2(3), both(4)  

dualdrr2xstateflagActChanSelect 1.3.6.1.4.1.1166.6.1.2.35.3.2.45
The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), readOnly(2), updateable(3)  

dualdrr2xlabelFactoryDefaultReset 1.3.6.1.4.1.1166.6.1.2.35.3.2.46
The value of this object provides the label of the Factory Default Reset Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xenumFactoryDefaultReset 1.3.6.1.4.1.1166.6.1.2.35.3.2.47
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xvalueFactoryDefaultReset 1.3.6.1.4.1.1166.6.1.2.35.3.2.48
The read of this value will return a invalid value. The read will not reflect the actual setting value for this parameter
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

dualdrr2xstateflagFactoryDefaultReset 1.3.6.1.4.1.1166.6.1.2.35.3.2.49
The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

gx2dualdrr2xStatusTableIndex 1.3.6.1.4.1.1166.6.1.2.35.4.3.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

dualdrr2xlabelBoot 1.3.6.1.4.1.1166.6.1.2.35.4.3.2
The value of this object provides the label of the Boot Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xvalueBoot 1.3.6.1.4.1.1166.6.1.2.35.4.3.3
The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

dualdrr2xstateflagBoot 1.3.6.1.4.1.1166.6.1.2.35.4.3.4
The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dualdrr2xlabelFlash 1.3.6.1.4.1.1166.6.1.2.35.4.3.5
The value of this object provides the label of the Flash Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xvalueFlash 1.3.6.1.4.1.1166.6.1.2.35.4.3.6
The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

dualdrr2xstateflagFlash 1.3.6.1.4.1.1166.6.1.2.35.4.3.7
The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dualdrr2xlabelFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.35.4.3.8
The value of this object provides the label of the Factory Data CRC Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xvalueFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.35.4.3.9
The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

dualdrr2xstateflagFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.35.4.3.10
The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dualdrr2xlabelAlarmDataCrc 1.3.6.1.4.1.1166.6.1.2.35.4.3.11
The value of this object provides the label of the Alarm Data Crc parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xvalueAlarmDataCrc 1.3.6.1.4.1.1166.6.1.2.35.4.3.12
The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

dualdrr2xstateflagAlarmDataCrc 1.3.6.1.4.1.1166.6.1.2.35.4.3.13
The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dualdrr2xlabelCalibrationDataCrc 1.3.6.1.4.1.1166.6.1.2.35.4.3.14
The value of this object provides the label of the Calibration Data Crc parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xvalueCalibrationDataCrc 1.3.6.1.4.1.1166.6.1.2.35.4.3.15
The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

dualdrr2xstateflagCalibrationDataCrc 1.3.6.1.4.1.1166.6.1.2.35.4.3.16
The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dualdrr2xlabelHardwareStatus 1.3.6.1.4.1.1166.6.1.2.35.4.3.17
The value of this object provides the label of the Module Hardware Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xvalueHardwareStatus 1.3.6.1.4.1.1166.6.1.2.35.4.3.18
The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

dualdrr2xstateflagHardwareStatus 1.3.6.1.4.1.1166.6.1.2.35.4.3.19
The value of this object provides the state of the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dualdrr2xlabelCh1TripPointStatus 1.3.6.1.4.1.1166.6.1.2.35.4.3.20
The value of this object provides the label of the Optical Trip Point Status parameter.It indicates whether the optical power is above(0) or below(1) trip point value
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xvalueCh1TripPointStatus 1.3.6.1.4.1.1166.6.1.2.35.4.3.21
The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

dualdrr2xstateflagCh1TripPointStatus 1.3.6.1.4.1.1166.6.1.2.35.4.3.22
The value of this object provides the state of the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dualdrr2xlabelLink1Status 1.3.6.1.4.1.1166.6.1.2.35.4.3.23
The value of this object provides the label of the Link Activity Status parameter. It represents receiver out of SYN with transmitter or Demux can not detect the optical signal.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xvalueLink1Status 1.3.6.1.4.1.1166.6.1.2.35.4.3.24
The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

dualdrr2xstateflagLink1Status 1.3.6.1.4.1.1166.6.1.2.35.4.3.25
The value of this object provides the state of the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dualdrr2xlabelCh2TripPointStatus 1.3.6.1.4.1.1166.6.1.2.35.4.3.26
The value of this object provides the label of the Optical Trip Point Status parameter.It indicates whether the optical power is above(0) or below(1) trip point value
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xvalueCh2TripPointStatus 1.3.6.1.4.1.1166.6.1.2.35.4.3.27
The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

dualdrr2xstateflagCh2TripPointStatus 1.3.6.1.4.1.1166.6.1.2.35.4.3.28
The value of this object provides the state of the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dualdrr2xlabelLink2Status 1.3.6.1.4.1.1166.6.1.2.35.4.3.29
The value of this object provides the label of the Link Activity Status parameter. It represents receiver out of SYN with transmitter or Demux can not detect the optical signal.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xvalueLink2Status 1.3.6.1.4.1.1166.6.1.2.35.4.3.30
The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

dualdrr2xstateflagLink2Status 1.3.6.1.4.1.1166.6.1.2.35.4.3.31
The value of this object provides the state of the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dualdrr2xlabelDRT1Status 1.3.6.1.4.1.1166.6.1.2.35.4.3.32
The value of this object provides the label of the Link Activity Status parameter. It represents receiver out of SYN with transmitter or Demux can not detect the optical signal.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xvalueDRT1Status 1.3.6.1.4.1.1166.6.1.2.35.4.3.33
The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

dualdrr2xstateflagDRT1Status 1.3.6.1.4.1.1166.6.1.2.35.4.3.34
The value of this object provides the state of the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dualdrr2xlabelSFP0Status 1.3.6.1.4.1.1166.6.1.2.35.4.3.35
The value of this object provides the label of the Link Activity Status parameter. It represents receiver out of SYN with transmitter or Demux can not detect the optical signal.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xvalueSFP0Status 1.3.6.1.4.1.1166.6.1.2.35.4.3.36
The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

dualdrr2xstateflagSFP0Status 1.3.6.1.4.1.1166.6.1.2.35.4.3.37
The value of this object provides the state of the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dualdrr2xlabelDRT2Status 1.3.6.1.4.1.1166.6.1.2.35.4.3.38
The value of this object provides the label of the Link Activity Status parameter. It represents receiver out of SYN with transmitter or Demux can not detect the optical signal.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xvalueDRT2Status 1.3.6.1.4.1.1166.6.1.2.35.4.3.39
The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

dualdrr2xstateflagDRT2Status 1.3.6.1.4.1.1166.6.1.2.35.4.3.40
The value of this object provides the state of the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

dualdrr2xlabelSFP1Status 1.3.6.1.4.1.1166.6.1.2.35.4.3.41
The value of this object provides the label of the Link Activity Status parameter. It represents receiver out of SYN with transmitter or Demux can not detect the optical signal.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xvalueSFP1Status 1.3.6.1.4.1.1166.6.1.2.35.4.3.42
The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

dualdrr2xstateflagSFP1Status 1.3.6.1.4.1.1166.6.1.2.35.4.3.43
The value of this object provides the state of the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

gx2dualdrr2xFactoryTableIndex 1.3.6.1.4.1.1166.6.1.2.35.5.4.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

dualdrr2xbootControlByte 1.3.6.1.4.1.1166.6.1.2.35.5.4.2
The value of this object indicates which bank the firmware is currently being boot from.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

dualdrr2xbootStatusByte 1.3.6.1.4.1.1166.6.1.2.35.5.4.3
This object indicates the status of the last boot
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

dualdrr2xbank1CRC 1.3.6.1.4.1.1166.6.1.2.35.5.4.4
This object provides the CRC code of bank 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

dualdrr2xbank2CRC 1.3.6.1.4.1.1166.6.1.2.35.5.4.5
This object provides the CRC code of bank 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

dualdrr2xprgEEPROMByte 1.3.6.1.4.1.1166.6.1.2.35.5.4.6
This object indicates if the EEPROM has been programmed
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

dualdrr2xfactoryCRC 1.3.6.1.4.1.1166.6.1.2.35.5.4.7
This object provides the CRC code for the Factory data.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

dualdrr2xcalculateCRC 1.3.6.1.4.1.1166.6.1.2.35.5.4.8
This object indicates which of the Emnums will have the CRC calculated (1-factory, 2-alarm, 3-calibration).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER factory(1), alarm(2), calibration(3)  

dualdrr2xhourMeter 1.3.6.1.4.1.1166.6.1.2.35.5.4.9
This object provides the hour meter reading of the module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

dualdrr2xflashPrgCntA 1.3.6.1.4.1.1166.6.1.2.35.5.4.10
This object provides the number of times Bank 0 flash has been programmed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

dualdrr2xflashPrgCntB 1.3.6.1.4.1.1166.6.1.2.35.5.4.11
This object provides the number of times Bank 1 flash has been programmed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

dualdrr2xflashBankARev 1.3.6.1.4.1.1166.6.1.2.35.5.4.12
This object provides the revision of flash bank 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xflashBankBRev 1.3.6.1.4.1.1166.6.1.2.35.5.4.13
This object provides the revision of flash bank 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xSubAgentRev 1.3.6.1.4.1.1166.6.1.2.35.5.4.14
This object provides the subagent revision of receiver module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xFPGA0FwRev 1.3.6.1.4.1.1166.6.1.2.35.5.4.15
This object provides the Firmware revision of the first DRR FPGA.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xFPGA1FwRev 1.3.6.1.4.1.1166.6.1.2.35.5.4.16
This object provides the Firmware revision of the second DRR FPGA.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xDRT1SerialNo 1.3.6.1.4.1.1166.6.1.2.35.5.4.17
This object provides the Serial Number of the DRT attached to channel 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xDRT1SFPSerialNo 1.3.6.1.4.1.1166.6.1.2.35.5.4.18
This object provides the Serial Number of the SFP in the DRT attached to channel 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xDRT1SFPPartNo 1.3.6.1.4.1.1166.6.1.2.35.5.4.19
This object provides the Part number of the SFP in the DRT attached to channel 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xDRT1FwRev 1.3.6.1.4.1.1166.6.1.2.35.5.4.20
This object provides the Firmware revision of the DRT attached to channel 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xDRT1FpgaFwRev 1.3.6.1.4.1.1166.6.1.2.35.5.4.21
This object provides the Firmware revision of the FPGA in the DRT attached to channel 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xDRT2SerialNo 1.3.6.1.4.1.1166.6.1.2.35.5.4.22
This object provides the Serial Number of the DRT attached to channel 2
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xDRT2SFPSerialNo 1.3.6.1.4.1.1166.6.1.2.35.5.4.23
This object provides the Serial Number of the SFP in the DRT attached to channel 2
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xDRT2SFPPartNo 1.3.6.1.4.1.1166.6.1.2.35.5.4.24
This object provides the Part number of the SFP in the DRT attached to channel 2.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xDRT2FwRev 1.3.6.1.4.1.1166.6.1.2.35.5.4.25
This object provides the Firmware revision of the DRT attached to channel 2.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

dualdrr2xDRT2FpgaFwRev 1.3.6.1.4.1.1166.6.1.2.35.5.4.26
This object provides the Firmware revision of the FPGA in the DRT attached to channel 2.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

trapdualdrrConfigChangeInteger 1
This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE    

trapdualdrrConfigChangeDisplayString 2
This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE    

trapdualdrr12VCurrentAlarm 3
This trap is issued when the 12V power supply Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapdualdrrModuleTempAlarm 4
This trap is issued when the Internal Module Temperature goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapdualdrrFanSpeedAlarm 5
This trap is issued when the Fan Speed parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapdualdrrFlashAlarm 6
This trap is issued when the detects an error during Flash memory operations.
TRAP-TYPE    

trapdualdrrBankBootAlarm 7
This trap is issued when the module detects an error while booting from bank 0 or bank 1.
TRAP-TYPE    

trapdualdrrAlarmDataCRCAlarm 8
This trap is issued when the Alarm Data CRC is incorrect.
TRAP-TYPE    

trapdualdrrHardwareErrAlarm 9
This trap is issued when hardware is abnormal.
TRAP-TYPE    

trapdualdrrOpticalSignal1Alarm 10
This trap is issued when the optical signal 1 is beyond the preset range.
TRAP-TYPE    

trapdualdrrOpticalSignal2Alarm 11
This trap is issued when the optical signal 2 is beyond the preset range.
TRAP-TYPE    

trapdualdrrFactoryDataCRCAlarm 12
This trap is issued when the Factory Data CRC is incorrect.
TRAP-TYPE    

trapdualdrrResetFactoryDefaultAlarm 13
This trap is issued when the Factory Default Reset occurs.
TRAP-TYPE    

trapdualdrrTripPoint1Alarm 14
This trap is issued when the Input 1 optical power is lower than the custumer set trip point and trippoint mode as ALARM_ONLY or SWITCH & ALARM.
TRAP-TYPE    

trapdualdrrTripPoint2Alarm 15
This trap is issued when the Input 2 optical power is lower than the custumer set trip point and trippoint mode as ALARM_ONLY or SWITCH & ALARM.
TRAP-TYPE    

trapdualdrrLink1Alarm 16
This trap is issued when receiver 1 is out of SYN with transmitter
TRAP-TYPE    

trapdualdrrLink2Alarm 17
This trap is issued when receiver 2 is out of SYN with transmitter
TRAP-TYPE    

trapdualdrrCalibrationDataCRCAlarm 18
This trap is issued when the Calibration Data CRC is incorrect
TRAP-TYPE    

trapdualdrrSFP1OptPWRAlarm 19
This trap is issued when SFP 1's optical power is incorrect
TRAP-TYPE    

trapdualdrrDRT1Cur24VAlarm 20
This trap is issued when DRT 1's 24 volt current is incorrect
TRAP-TYPE    

trapdualdrrDRT1ModTempAarm 21
This trap is issued when DRT 1's Module telperature is incorrect
TRAP-TYPE    

trapdualdrrSFP2OptPWRAlarm 22
This trap is issued when SFP 2's optical power is incorrect
TRAP-TYPE    

trapdualdrrDRT2Cur24VAlarm 23
This trap is issued when DRT 2's 24 volt current is incorrect
TRAP-TYPE    

trapdualdrrDRT2ModTempAarm 24
This trap is issued when DRT 2's Module telperature is incorrect
TRAP-TYPE