OMNI-gx2drr4x-MIB

File: OMNI-gx2drr4x-MIB.mib (82134 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC1213-MIB
RFC-1215 GX2HFC-MIB NLSBBN-TRAPS-MIB

Imported symbols

IpAddress TimeTicks Counter
OBJECT-TYPE DisplayString TRAP-TYPE
gx2Drr4x trapIdentifier trapNetworkElemModelNumber
trapNetworkElemSerialNum trapPerceivedSeverity trapNetworkElemOperState
trapNetworkElemAlarmStatus trapNetworkElemAdminState trapNetworkElemAvailStatus
trapText trapNETrapLastTrapTimeStamp trapChangedObjectId
trapChangedValueInteger trapChangedValueDisplayString

Defined Types

Float  
Counter    

Gx2drr4xAnalogEntry  
SEQUENCE    
  gx2drr4xAnalogTableIndex INTEGER
  drr4xlabelRFAAttenuation DisplayString Size(0..80)
  drr4xuomRFAAttenuation DisplayString Size(0..80)
  drr4xmajorHighRFAAttenuation Float
  drr4xmajorLowRFAAttenuation Float
  drr4xminorHighRFAAttenuation Float
  drr4xminorLowRFAAttenuation Float
  drr4xcurrentValueRFAAttenuation Float
  drr4xstateFlagRFAAttenuation INTEGER
  drr4xminValueRFAAttenuation Float
  drr4xmaxValueRFAAttenuation Float
  drr4xalarmStateRFAAttenuation INTEGER
  drr4xlabelRFBAttenuation DisplayString Size(0..80)
  drr4xuomRFBAttenuation DisplayString Size(0..80)
  drr4xmajorHighRFBAttenuation Float
  drr4xmajorLowRFBAttenuation Float
  drr4xminorHighRFBAttenuation Float
  drr4xminorLowRFBAttenuation Float
  drr4xcurrentValueRFBAttenuation Float
  drr4xstateFlagRFBAttenuation INTEGER
  drr4xminValueRFBAttenuation Float
  drr4xmaxValueRFBAttenuation Float
  drr4xalarmStateRFBAttenuation INTEGER
  drr4xlabelRFCAttenuation DisplayString Size(0..80)
  drr4xuomRFCAttenuation DisplayString Size(0..80)
  drr4xmajorHighRFCAttenuation Float
  drr4xmajorLowRFCAttenuation Float
  drr4xminorHighRFCAttenuation Float
  drr4xminorLowRFCAttenuation Float
  drr4xcurrentValueRFCAttenuation Float
  drr4xstateFlagRFCAttenuation INTEGER
  drr4xminValueRFCAttenuation Float
  drr4xmaxValueRFCAttenuation Float
  drr4xalarmStateRFCAttenuation INTEGER
  drr4xlabelRFDAttenuation DisplayString Size(0..80)
  drr4xuomRFDAttenuation DisplayString Size(0..80)
  drr4xmajorHighRFDAttenuation Float
  drr4xmajorLowRFDAttenuation Float
  drr4xminorHighRFDAttenuation Float
  drr4xminorLowRFDAttenuation Float
  drr4xcurrentValueRFDAttenuation Float
  drr4xstateFlagRFDAttenuation INTEGER
  drr4xminValueRFDAttenuation Float
  drr4xmaxValueRFDAttenuation Float
  drr4xalarmStateRFDAttenuation INTEGER
  drr4xlabelTrippointLevel DisplayString Size(0..80)
  drr4xuomTrippointLevel DisplayString Size(0..80)
  drr4xmajorHighTrippointLevel Float
  drr4xmajorLowTrippointLevel Float
  drr4xminorHighTrippointLevel Float
  drr4xminorLowTrippointLevel Float
  drr4xcurrentValueTrippointLevel Float
  drr4xstateFlagTrippointLevel INTEGER
  drr4xminValueTrippointLevel Float
  drr4xmaxValueTrippointLevel Float
  drr4xalarmStateTrippointLevel INTEGER
  drr4xlabelOptCurrent DisplayString Size(0..80)
  drr4xuomOptCurrent DisplayString Size(0..80)
  drr4xmajorHighOptCurrent Float
  drr4xmajorLowOptCurrent Float
  drr4xminorHighOptCurrent Float
  drr4xminorLowOptCurrent Float
  drr4xcurrentValueOptCurrent Float
  drr4xstateFlagOptCurrent INTEGER
  drr4xminValueOptCurrent Float
  drr4xmaxValueOptCurrent Float
  drr4xalarmStateOptCurrent INTEGER
  drr4xlabel12VCurrent DisplayString Size(0..80)
  drr4xuom12VCurrent DisplayString Size(0..80)
  drr4xmajorHigh12VCurrent Float
  drr4xmajorLow12VCurrent Float
  drr4xminorHigh12VCurrent Float
  drr4xminorLow12VCurrent Float
  drr4xcurrentValue12VCurrent Float
  drr4xstateFlag12VCurrent INTEGER
  drr4xminValue12VCurrent Float
  drr4xmaxValue12VCurrent Float
  drr4xalarmState12VCurrent INTEGER
  drr4xlabelModTemp DisplayString Size(0..80)
  drr4xuomModTemp DisplayString Size(0..80)
  drr4xmajorHighModTemp Float
  drr4xmajorLowModTemp Float
  drr4xminorHighModTemp Float
  drr4xminorLowModTemp Float
  drr4xcurrentValueModTemp Float
  drr4xstateFlagModTemp INTEGER
  drr4xminValueModTemp Float
  drr4xmaxValueModTemp Float
  drr4xalarmStateModTemp INTEGER
  drr4xlabelFanCurrent DisplayString Size(0..80)
  drr4xuomFanCurrent DisplayString Size(0..80)
  drr4xmajorHighFanCurrent Float
  drr4xmajorLowFanCurrent Float
  drr4xminorHighFanCurrent Float
  drr4xminorLowFanCurrent Float
  drr4xcurrentValueFanCurrent Float
  drr4xstateFlagFanCurrent INTEGER
  drr4xminValueFanCurrent Float
  drr4xmaxValueFanCurrent Float
  drr4xalarmStateFanCurrent INTEGER

Gx2drr4xDigitalEntry  
SEQUENCE    
  gx2drr4xDigitalTableIndex INTEGER
  drr4xlabelTrippointMode DisplayString Size(0..80)
  drr4xenumTrippointMode DisplayString Size(0..80)
  drr4xvalueTrippointMode INTEGER
  drr4xstateflagTrippointMode INTEGER
  drr4xlabelFactoryDefaultReset DisplayString Size(0..80)
  drr4xenumFactoryDefaultReset DisplayString Size(0..80)
  drr4xvalueFactoryDefaultReset INTEGER
  drr4xstateflagFactoryDefaultReset INTEGER

Gx2drr4xStatusEntry  
SEQUENCE    
  gx2drr4xStatusTableIndex INTEGER
  drr4xlabelBoot DisplayString Size(0..80)
  drr4xvalueBoot INTEGER
  drr4xstateflagBoot INTEGER
  drr4xlabelFlash DisplayString Size(0..80)
  drr4xvalueFlash INTEGER
  drr4xstateflagFlash INTEGER
  drr4xlabelFactoryDataCRC DisplayString Size(0..80)
  drr4xvalueFactoryDataCRC INTEGER
  drr4xstateflagFactoryDataCRC INTEGER
  drr4xlabelAlarmDataCrc DisplayString Size(0..80)
  drr4xvalueAlarmDataCrc INTEGER
  drr4xstateflagAlarmDataCrc INTEGER
  drr4xlabelCalibrationDataCrc DisplayString Size(0..80)
  drr4xvalueCalibrationDataCrc INTEGER
  drr4xstateflagCalibrationDataCrc INTEGER
  drr4xlabelHardwareStatus DisplayString Size(0..80)
  drr4xvalueHardwareStatus INTEGER
  drr4xstateflagHardwareStatus INTEGER
  drr4xlabelOpticTripPointStatus DisplayString Size(0..80)
  drr4xvalueOpticTripPointStatus INTEGER
  drr4xstateflagOpticTripPointStatus INTEGER
  drr4xlabelLinkStatus DisplayString Size(0..80)
  drr4xvalueLinkStatus INTEGER
  drr4xstateflagLinkStatus INTEGER

Gx2drr4xFactoryEntry  
SEQUENCE    
  gx2drr4xFactoryTableIndex INTEGER
  drr4xbootControlByte INTEGER
  drr4xbootStatusByte INTEGER
  drr4xbank1CRC INTEGER
  drr4xbank2CRC INTEGER
  drr4xprgEEPROMByte INTEGER
  drr4xfactoryCRC INTEGER
  drr4xcalculateCRC INTEGER
  drr4xhourMeter INTEGER
  drr4xflashPrgCntA INTEGER
  drr4xflashPrgCntB INTEGER
  drr4xflashBankARev DisplayString Size(0..80)
  drr4xflashBankBRev DisplayString Size(0..80)
  drr4xSubAgentRev DisplayString Size(0..80)

Defined Values

gx2drr4xDescriptor 1.3.6.1.4.1.1166.6.1.2.14.1
OBJECT IDENTIFIER    

gx2drr4xAnalogTable 1.3.6.1.4.1.1166.6.1.2.14.2
This table contains gx2drr4x specific analog parameters with nominal,limits and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2drr4xAnalogEntry

gx2drr4xAnalogEntry 1.3.6.1.4.1.1166.6.1.2.14.2.1
This list contains the analog parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2drr4xAnalogEntry  

gx2drr4xDigitalTable 1.3.6.1.4.1.1166.6.1.2.14.3
This table contains gx2drr4x specific digital parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2drr4xDigitalEntry

gx2drr4xDigitalEntry 1.3.6.1.4.1.1166.6.1.2.14.3.2
This list contains individual digital parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2drr4xDigitalEntry  

gx2drr4xStatusTable 1.3.6.1.4.1.1166.6.1.2.14.4
This table contains gx2drr4x specific status parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2drr4xStatusEntry

gx2drr4xStatusEntry 1.3.6.1.4.1.1166.6.1.2.14.4.3
This list contains Status parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2drr4xStatusEntry  

gx2drr4xFactoryTable 1.3.6.1.4.1.1166.6.1.2.14.5
This table contains gx2drr4x specific factory setting parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2drr4xFactoryEntry

gx2drr4xFactoryEntry 1.3.6.1.4.1.1166.6.1.2.14.5.4
This list contains Factory setting parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2drr4xFactoryEntry  

gx2drr4xAnalogTableIndex 1.3.6.1.4.1.1166.6.1.2.14.2.1.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

drr4xlabelRFAAttenuation 1.3.6.1.4.1.1166.6.1.2.14.2.1.2
The value of this object provides the label of the RF Channel A Attenuation Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr4xuomRFAAttenuation 1.3.6.1.4.1.1166.6.1.2.14.2.1.3
The value of this object provides the Unit of Measure of the RF Channel A Attenuation Analog parameter. The unit is in dB
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr4xmajorHighRFAAttenuation 1.3.6.1.4.1.1166.6.1.2.14.2.1.4
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

drr4xmajorLowRFAAttenuation 1.3.6.1.4.1.1166.6.1.2.14.2.1.5
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

drr4xminorHighRFAAttenuation 1.3.6.1.4.1.1166.6.1.2.14.2.1.6
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

drr4xminorLowRFAAttenuation 1.3.6.1.4.1.1166.6.1.2.14.2.1.7
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

drr4xcurrentValueRFAAttenuation 1.3.6.1.4.1.1166.6.1.2.14.2.1.8
The value of this object provides the Current value of the RF Channel A Attenuation Analog parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Float  

drr4xstateFlagRFAAttenuation 1.3.6.1.4.1.1166.6.1.2.14.2.1.9
The value of this object provides the state of the RF Channel A Attenuation Analog parameter. (1-hidden 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

drr4xminValueRFAAttenuation 1.3.6.1.4.1.1166.6.1.2.14.2.1.10
The value of this object provides the minimum value the RF Channel A Attenuation Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr4xmaxValueRFAAttenuation 1.3.6.1.4.1.1166.6.1.2.14.2.1.11
The value of this object provides the maximum value the RF Channel A Attenuation Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr4xalarmStateRFAAttenuation 1.3.6.1.4.1.1166.6.1.2.14.2.1.12
The value of this object provides the curent alarm state of the RF Channel A Attenuation Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

drr4xlabelRFBAttenuation 1.3.6.1.4.1.1166.6.1.2.14.2.1.13
The value of this object provides the label of the RF Channel B Attenuation Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr4xuomRFBAttenuation 1.3.6.1.4.1.1166.6.1.2.14.2.1.14
The value of this object provides the Unit of Measure of the RF Channel B Attenuation Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr4xmajorHighRFBAttenuation 1.3.6.1.4.1.1166.6.1.2.14.2.1.15
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

drr4xmajorLowRFBAttenuation 1.3.6.1.4.1.1166.6.1.2.14.2.1.16
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

drr4xminorHighRFBAttenuation 1.3.6.1.4.1.1166.6.1.2.14.2.1.17
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

drr4xminorLowRFBAttenuation 1.3.6.1.4.1.1166.6.1.2.14.2.1.18
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

drr4xcurrentValueRFBAttenuation 1.3.6.1.4.1.1166.6.1.2.14.2.1.19
The value of this object provides the Current value of the RF Channel B Attenuation Analog parameter. The unit is dB
Status: mandatory Access: read-write
OBJECT-TYPE    
  Float  

drr4xstateFlagRFBAttenuation 1.3.6.1.4.1.1166.6.1.2.14.2.1.20
The value of this object provides the state of the RF Channel B Attenuation Analog parameter. (1-hidden 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

drr4xminValueRFBAttenuation 1.3.6.1.4.1.1166.6.1.2.14.2.1.21
The value of this object provides the minimum value the RF Channel B Attenuation Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr4xmaxValueRFBAttenuation 1.3.6.1.4.1.1166.6.1.2.14.2.1.22
The value of this object provides the maximum value the RF Channel B Attenuation Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr4xalarmStateRFBAttenuation 1.3.6.1.4.1.1166.6.1.2.14.2.1.23
The value of this object provides the curent alarm state of the RF Channel B Attenuation Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

drr4xlabelRFCAttenuation 1.3.6.1.4.1.1166.6.1.2.14.2.1.24
The value of this object provides the label of the RF Channel C Attenuation Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr4xuomRFCAttenuation 1.3.6.1.4.1.1166.6.1.2.14.2.1.25
The value of this object provides the Unit of Measure of the RF Channel C Attenuation Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr4xmajorHighRFCAttenuation 1.3.6.1.4.1.1166.6.1.2.14.2.1.26
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

drr4xmajorLowRFCAttenuation 1.3.6.1.4.1.1166.6.1.2.14.2.1.27
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

drr4xminorHighRFCAttenuation 1.3.6.1.4.1.1166.6.1.2.14.2.1.28
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

drr4xminorLowRFCAttenuation 1.3.6.1.4.1.1166.6.1.2.14.2.1.29
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

drr4xcurrentValueRFCAttenuation 1.3.6.1.4.1.1166.6.1.2.14.2.1.30
The value of this object provides the Current value of the RF Channel C Attenuation Analog parameter. The unit is dB
Status: mandatory Access: read-write
OBJECT-TYPE    
  Float  

drr4xstateFlagRFCAttenuation 1.3.6.1.4.1.1166.6.1.2.14.2.1.31
The value of this object provides the state of the RF Channel C Attenuation Analog parameter. (1-hidden 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

drr4xminValueRFCAttenuation 1.3.6.1.4.1.1166.6.1.2.14.2.1.32
The value of this object provides the minimum value the RF Channel C Attenuation Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr4xmaxValueRFCAttenuation 1.3.6.1.4.1.1166.6.1.2.14.2.1.33
The value of this object provides the maximum value the RF Channel C Attenuation Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr4xalarmStateRFCAttenuation 1.3.6.1.4.1.1166.6.1.2.14.2.1.34
The value of this object provides the curent alarm state of the RF Channel C Attenuation Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

drr4xlabelRFDAttenuation 1.3.6.1.4.1.1166.6.1.2.14.2.1.35
The value of this object provides the label of the RF Channel D Attenuation Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr4xuomRFDAttenuation 1.3.6.1.4.1.1166.6.1.2.14.2.1.36
The value of this object provides the Unit of Measure of the RF Channel D Attenuation Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr4xmajorHighRFDAttenuation 1.3.6.1.4.1.1166.6.1.2.14.2.1.37
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

drr4xmajorLowRFDAttenuation 1.3.6.1.4.1.1166.6.1.2.14.2.1.38
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

drr4xminorHighRFDAttenuation 1.3.6.1.4.1.1166.6.1.2.14.2.1.39
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

drr4xminorLowRFDAttenuation 1.3.6.1.4.1.1166.6.1.2.14.2.1.40
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF. It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

drr4xcurrentValueRFDAttenuation 1.3.6.1.4.1.1166.6.1.2.14.2.1.41
The value of this object provides the Current value of the RF Channel D Attenuation Analog parameter. The unit is dB
Status: mandatory Access: read-write
OBJECT-TYPE    
  Float  

drr4xstateFlagRFDAttenuation 1.3.6.1.4.1.1166.6.1.2.14.2.1.42
The value of this object provides the state of the RF Channel D Attenuation Analog parameter. (1-hidden 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

drr4xminValueRFDAttenuation 1.3.6.1.4.1.1166.6.1.2.14.2.1.43
The value of this object provides the minimum value the RF Channel B Attenuation Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr4xmaxValueRFDAttenuation 1.3.6.1.4.1.1166.6.1.2.14.2.1.44
The value of this object provides the maximum value the RF Channel D Attenuation Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr4xalarmStateRFDAttenuation 1.3.6.1.4.1.1166.6.1.2.14.2.1.45
The value of this object provides the curent alarm state of the RF Channel D Attenuation Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

drr4xlabelTrippointLevel 1.3.6.1.4.1.1166.6.1.2.14.2.1.46
The value of this object provides the label of the trip point level Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr4xuomTrippointLevel 1.3.6.1.4.1.1166.6.1.2.14.2.1.47
The value of this object provides the Unit of Measure of the trip point level Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr4xmajorHighTrippointLevel 1.3.6.1.4.1.1166.6.1.2.14.2.1.48
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

drr4xmajorLowTrippointLevel 1.3.6.1.4.1.1166.6.1.2.14.2.1.49
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

drr4xminorHighTrippointLevel 1.3.6.1.4.1.1166.6.1.2.14.2.1.50
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

drr4xminorLowTrippointLevel 1.3.6.1.4.1.1166.6.1.2.14.2.1.51
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

drr4xcurrentValueTrippointLevel 1.3.6.1.4.1.1166.6.1.2.14.2.1.52
The value of this object provides the Current value of the trip point level Analog parameter. The trip point level set the custumer preferred optical input level. This parameter combined with trippoint mode decides the trippoint alarm and RF channel output impedance. when optical power level is lower than trip point level(Set by this parameter) 1) When trip point mode is ALARM_SWITCH, trip point alarm will be generated and RF output impedance will be changed to high impedance. 2) When trippoint mode is ALARM_ONLY, trippoint alarm will be generated but RF output inpedance remains to be low impedance. This trip point level value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Float  

drr4xstateFlagTrippointLevel 1.3.6.1.4.1.1166.6.1.2.14.2.1.53
The value of this object provides the state of the trip point level Analog parameter. (1-hidden 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

drr4xminValueTrippointLevel 1.3.6.1.4.1.1166.6.1.2.14.2.1.54
The value of this object provides the minimum value the trip point level Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr4xmaxValueTrippointLevel 1.3.6.1.4.1.1166.6.1.2.14.2.1.55
The value of this object provides the maximum value the trip point level Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr4xalarmStateTrippointLevel 1.3.6.1.4.1.1166.6.1.2.14.2.1.56
The value of this object provides the curent alarm state of the trip point level Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

drr4xlabelOptCurrent 1.3.6.1.4.1.1166.6.1.2.14.2.1.57
The value of this object provides the label of the Optical Power Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr4xuomOptCurrent 1.3.6.1.4.1.1166.6.1.2.14.2.1.58
The value of this object provides the Unit of Measure of the Optical Power Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr4xmajorHighOptCurrent 1.3.6.1.4.1.1166.6.1.2.14.2.1.59
The value of this object provides the Major High alarm value of the Optical Power Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr4xmajorLowOptCurrent 1.3.6.1.4.1.1166.6.1.2.14.2.1.60
The value of this object provides the Major Low alarm value of the Optical Power Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr4xminorHighOptCurrent 1.3.6.1.4.1.1166.6.1.2.14.2.1.61
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

drr4xminorLowOptCurrent 1.3.6.1.4.1.1166.6.1.2.14.2.1.62
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

drr4xcurrentValueOptCurrent 1.3.6.1.4.1.1166.6.1.2.14.2.1.63
The value of this object provides the Current value of the Optical Power Current Analog parameter. The input optical power in lower than min value, drr4xcurrentValueOptCurrent will report -99dBm The input optical power in higher than this value, drr4xcurrentValueOptCurrent will report 99dBm
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr4xstateFlagOptCurrent 1.3.6.1.4.1.1166.6.1.2.14.2.1.64
The value of this object provides the state of the Optical Power Current Analog parameter. (1-hidden 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

drr4xminValueOptCurrent 1.3.6.1.4.1.1166.6.1.2.14.2.1.65
This is recommended min range for display gauge
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr4xmaxValueOptCurrent 1.3.6.1.4.1.1166.6.1.2.14.2.1.66
This is recommended max range for display gauge
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr4xalarmStateOptCurrent 1.3.6.1.4.1.1166.6.1.2.14.2.1.67
The value of this object provides the curent alarm state of the Optical Power Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

drr4xlabel12VCurrent 1.3.6.1.4.1.1166.6.1.2.14.2.1.68
The value of this object provides the label of the 12v power supply Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr4xuom12VCurrent 1.3.6.1.4.1.1166.6.1.2.14.2.1.69
The value of this object provides the Unit of Measure of the 12v power supply Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr4xmajorHigh12VCurrent 1.3.6.1.4.1.1166.6.1.2.14.2.1.70
The value of this object provides the Major High alarm value of the 12v power supply Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr4xmajorLow12VCurrent 1.3.6.1.4.1.1166.6.1.2.14.2.1.71
The value of this object provides the Major Low alarm value of the 12v power supply Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr4xminorHigh12VCurrent 1.3.6.1.4.1.1166.6.1.2.14.2.1.72
The value of this object provides the Minor High alarm value of the 12v power supply Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr4xminorLow12VCurrent 1.3.6.1.4.1.1166.6.1.2.14.2.1.73
The value of this object provides the Minor Low alarm value of the 12v power supply Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr4xcurrentValue12VCurrent 1.3.6.1.4.1.1166.6.1.2.14.2.1.74
The value of this object provides the Current value of the 12v power supply Current parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr4xstateFlag12VCurrent 1.3.6.1.4.1.1166.6.1.2.14.2.1.75
The value of this object provides the state of the 12v power supply Current Analog parameter. (1-hidden 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

drr4xminValue12VCurrent 1.3.6.1.4.1.1166.6.1.2.14.2.1.76
The value of this object provides the minimum value the 12v power supply Current Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr4xmaxValue12VCurrent 1.3.6.1.4.1.1166.6.1.2.14.2.1.77
The value of this object provides the maximum value the 12v power supply Current Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr4xalarmState12VCurrent 1.3.6.1.4.1.1166.6.1.2.14.2.1.78
The value of this object provides the curent alarm state of the 12v power supply Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

drr4xlabelModTemp 1.3.6.1.4.1.1166.6.1.2.14.2.1.79
The value of this object provides the label of the Module Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr4xuomModTemp 1.3.6.1.4.1.1166.6.1.2.14.2.1.80
The value of this object provides the Unit of Measure of the Module Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr4xmajorHighModTemp 1.3.6.1.4.1.1166.6.1.2.14.2.1.81
The value of this object provides the Major High alarm value of the Module Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr4xmajorLowModTemp 1.3.6.1.4.1.1166.6.1.2.14.2.1.82
The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr4xminorHighModTemp 1.3.6.1.4.1.1166.6.1.2.14.2.1.83
The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr4xminorLowModTemp 1.3.6.1.4.1.1166.6.1.2.14.2.1.84
The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr4xcurrentValueModTemp 1.3.6.1.4.1.1166.6.1.2.14.2.1.85
The value of this object provides the Current value of the Module Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr4xstateFlagModTemp 1.3.6.1.4.1.1166.6.1.2.14.2.1.86
The value of this object provides the state of the Module Temperature Analog parameter. (1-hidden 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

drr4xminValueModTemp 1.3.6.1.4.1.1166.6.1.2.14.2.1.87
The value of this object provides the minimum value the Module Temperature Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr4xmaxValueModTemp 1.3.6.1.4.1.1166.6.1.2.14.2.1.88
The value of this object provides the maximum value the Module Temperature Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr4xalarmStateModTemp 1.3.6.1.4.1.1166.6.1.2.14.2.1.89
The value of this object provides the curent alarm state of the Module Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

drr4xlabelFanCurrent 1.3.6.1.4.1.1166.6.1.2.14.2.1.90
The value of this object provides the label of the Fan Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr4xuomFanCurrent 1.3.6.1.4.1.1166.6.1.2.14.2.1.91
The value of this object provides the Unit of Measure of the Fan Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr4xmajorHighFanCurrent 1.3.6.1.4.1.1166.6.1.2.14.2.1.92
The value of this object provides the Major High alarm value of the Fan Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr4xmajorLowFanCurrent 1.3.6.1.4.1.1166.6.1.2.14.2.1.93
The value of this object provides the Major Low alarm value of the Fan Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr4xminorHighFanCurrent 1.3.6.1.4.1.1166.6.1.2.14.2.1.94
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

drr4xminorLowFanCurrent 1.3.6.1.4.1.1166.6.1.2.14.2.1.95
This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . It is kept here for persistence.
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

drr4xcurrentValueFanCurrent 1.3.6.1.4.1.1166.6.1.2.14.2.1.96
The value of this object provides the Current value of the Fan Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr4xstateFlagFanCurrent 1.3.6.1.4.1.1166.6.1.2.14.2.1.97
The value of this object provides the state of the Module Temperature Analog parameter. (1-hidden 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

drr4xminValueFanCurrent 1.3.6.1.4.1.1166.6.1.2.14.2.1.98
The value of this object provides the minimum value the Fan Current Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr4xmaxValueFanCurrent 1.3.6.1.4.1.1166.6.1.2.14.2.1.99
The value of this object provides the maximum value the Fan Current Analog parameter can achive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

drr4xalarmStateFanCurrent 1.3.6.1.4.1.1166.6.1.2.14.2.1.100
The value of this object provides the curent alarm state of the Fan Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

gx2drr4xDigitalTableIndex 1.3.6.1.4.1.1166.6.1.2.14.3.2.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

drr4xlabelTrippointMode 1.3.6.1.4.1.1166.6.1.2.14.3.2.2
The value of this object provides the label of the Trip point mode Digital parameter. The trip point mode defines the RF switch action based on the optical power input to the DRR
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr4xenumTrippointMode 1.3.6.1.4.1.1166.6.1.2.14.3.2.3
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr4xvalueTrippointMode 1.3.6.1.4.1.1166.6.1.2.14.3.2.4
The value of this object is the current value of trip point mode. There are three possible value: 1-off, 2-alarm_only, 3-alarm&switch. If module input optical power is higher than the preset trippoint value, no operational difference for these three modes. If module input optical power is less than the preset trippoint value, 1) When trippoint mode is OFF, no trippoint alarm will be generated and RF output impedance will stay normal as low. 2) When tripoint mode is ALARM_ONLY, trip_point alarm will be generated when the input optical power lower than the preset trippoint level but RF output impedance will stay normal as low. 3) When trippoint mode is ALARM_SWITCH, trip point alarm will be generated and RF output impedance will switch to abnorml
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), alarmOnly(2), alarm-and-Switch(3)  

drr4xstateflagTrippointMode 1.3.6.1.4.1.1166.6.1.2.14.3.2.5
The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), readOnly(2), updateable(3)  

drr4xlabelFactoryDefaultReset 1.3.6.1.4.1.1166.6.1.2.14.3.2.6
The value of this object provides the label of the Factory Default Reset Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr4xenumFactoryDefaultReset 1.3.6.1.4.1.1166.6.1.2.14.3.2.7
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr4xvalueFactoryDefaultReset 1.3.6.1.4.1.1166.6.1.2.14.3.2.8
The read of this value will return a invalid value. The read will not reflect the actual setting value for this parameter
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

drr4xstateflagFactoryDefaultReset 1.3.6.1.4.1.1166.6.1.2.14.3.2.9
The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

gx2drr4xStatusTableIndex 1.3.6.1.4.1.1166.6.1.2.14.4.3.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

drr4xlabelBoot 1.3.6.1.4.1.1166.6.1.2.14.4.3.2
The value of this object provides the label of the Boot Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr4xvalueBoot 1.3.6.1.4.1.1166.6.1.2.14.4.3.3
The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

drr4xstateflagBoot 1.3.6.1.4.1.1166.6.1.2.14.4.3.4
The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

drr4xlabelFlash 1.3.6.1.4.1.1166.6.1.2.14.4.3.5
The value of this object provides the label of the Flash Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr4xvalueFlash 1.3.6.1.4.1.1166.6.1.2.14.4.3.6
The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

drr4xstateflagFlash 1.3.6.1.4.1.1166.6.1.2.14.4.3.7
The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

drr4xlabelFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.14.4.3.8
The value of this object provides the label of the Factory Data CRC Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr4xvalueFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.14.4.3.9
The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

drr4xstateflagFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.14.4.3.10
The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

drr4xlabelAlarmDataCrc 1.3.6.1.4.1.1166.6.1.2.14.4.3.11
The value of this object provides the label of the Alarm Data Crc parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr4xvalueAlarmDataCrc 1.3.6.1.4.1.1166.6.1.2.14.4.3.12
The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

drr4xstateflagAlarmDataCrc 1.3.6.1.4.1.1166.6.1.2.14.4.3.13
The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

drr4xlabelCalibrationDataCrc 1.3.6.1.4.1.1166.6.1.2.14.4.3.14
The value of this object provides the label of the Calibration Data Crc parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr4xvalueCalibrationDataCrc 1.3.6.1.4.1.1166.6.1.2.14.4.3.15
The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

drr4xstateflagCalibrationDataCrc 1.3.6.1.4.1.1166.6.1.2.14.4.3.16
The value of this object provides the state of the the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

drr4xlabelHardwareStatus 1.3.6.1.4.1.1166.6.1.2.14.4.3.17
The value of this object provides the label of the Module Hardware Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr4xvalueHardwareStatus 1.3.6.1.4.1.1166.6.1.2.14.4.3.18
The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

drr4xstateflagHardwareStatus 1.3.6.1.4.1.1166.6.1.2.14.4.3.19
The value of this object provides the state of the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

drr4xlabelOpticTripPointStatus 1.3.6.1.4.1.1166.6.1.2.14.4.3.20
The value of this object provides the label of the Optical Trip Point Status parameter.It indicates whether the optical power is above(0) or below(1) trip point value
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr4xvalueOpticTripPointStatus 1.3.6.1.4.1.1166.6.1.2.14.4.3.21
The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

drr4xstateflagOpticTripPointStatus 1.3.6.1.4.1.1166.6.1.2.14.4.3.22
The value of this object provides the state of the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

drr4xlabelLinkStatus 1.3.6.1.4.1.1166.6.1.2.14.4.3.23
The value of this object provides the label of the Link Activity Status parameter. It represents receiver out of SYN with transmitter or Demux can not detect the optical signal.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr4xvalueLinkStatus 1.3.6.1.4.1.1166.6.1.2.14.4.3.24
The value of this object provides the current state of the parameter (1-Ok, 2-Undetermined 3-Warning, 4-Minor, 5-Major, 6-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

drr4xstateflagLinkStatus 1.3.6.1.4.1.1166.6.1.2.14.4.3.25
The value of this object provides the state of the parameter. (1-Hidden 2-Read-Only, 3-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

gx2drr4xFactoryTableIndex 1.3.6.1.4.1.1166.6.1.2.14.5.4.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

drr4xbootControlByte 1.3.6.1.4.1.1166.6.1.2.14.5.4.2
The value of this object indicates which bank the firmware is currently being boot from.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

drr4xbootStatusByte 1.3.6.1.4.1.1166.6.1.2.14.5.4.3
This object indicates the status of the last boot
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

drr4xbank1CRC 1.3.6.1.4.1.1166.6.1.2.14.5.4.4
This object provides the CRC code of bank 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

drr4xbank2CRC 1.3.6.1.4.1.1166.6.1.2.14.5.4.5
This object provides the CRC code of bank 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

drr4xprgEEPROMByte 1.3.6.1.4.1.1166.6.1.2.14.5.4.6
This object indicates if the EEPROM has been programmed
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

drr4xfactoryCRC 1.3.6.1.4.1.1166.6.1.2.14.5.4.7
This object provides the CRC code for the Factory data.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

drr4xcalculateCRC 1.3.6.1.4.1.1166.6.1.2.14.5.4.8
This object indicates which of the Emnums will have the CRC calculated (1-factory, 2-alarm, 3-calibration).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER factory(1), alarm(2), calibration(3)  

drr4xhourMeter 1.3.6.1.4.1.1166.6.1.2.14.5.4.9
This object provides the hour meter reading of the module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

drr4xflashPrgCntA 1.3.6.1.4.1.1166.6.1.2.14.5.4.10
This object provides the number of times Bank 0 flash has been programmed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

drr4xflashPrgCntB 1.3.6.1.4.1.1166.6.1.2.14.5.4.11
This object provides the number of times Bank 1 flash has been programmed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

drr4xflashBankARev 1.3.6.1.4.1.1166.6.1.2.14.5.4.12
This object provides the revision of flash bank 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr4xflashBankBRev 1.3.6.1.4.1.1166.6.1.2.14.5.4.13
This object provides the revision of flash bank 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

drr4xSubAgentRev 1.3.6.1.4.1.1166.6.1.2.14.5.4.14
This object provides the subagent revision of receiver module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

trapdrrConfigChangeInteger 1
This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE    

trapdrrConfigChangeDisplayString 2
This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE    

trapdrr12VCurrentAlarm 3
This trap is issued when the 12V power supply Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapdrrModuleTempAlarm 4
This trap is issued when the Internal Module Temperature goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapdrrFanCurrentAlarm 5
This trap is issued when the Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapdrrFlashAlarm 6
This trap is issued when the detects an error during Flash memory operations.
TRAP-TYPE    

trapdrrBankBootAlarm 7
This trap is issued when the module detects an error while booting from bank 0 or bank 1.
TRAP-TYPE    

trapdrrAlarmDataCRCAlarm 8
This trap is issued when the Alarm Data CRC is incorrect.
TRAP-TYPE    

trapdrrHardwareErrAlarm 9
This trap is issued when hardware is abnormal.
TRAP-TYPE    

trapdrrOpticalSignalAlarm 10
This trap is issued when the optical signal is beyond the preset range.
TRAP-TYPE    

trapdrrFactoryDataCRCAlarm 11
This trap is issued when the Factory Data CRC is incorrect.
TRAP-TYPE    

trapdrrResetFactoryDefaultAlarm 12
This trap is issued when the Factory Default Reset occurs.
TRAP-TYPE    

trapdrrTripPointAlarm 13
This trap is issued when the Input optical power is lower than the custumer set trip point and trippoint mode as ALARM_ONLY or SWITCH & ALARM.
TRAP-TYPE    

trapdrrLinkAlarm 14
This trap is issued when receiver is out of SYN with transmitter
TRAP-TYPE    

trapdrrCalibrationDataCRCAlarm 15
This trap is issued when the Calibration Data CRC is incorrect
TRAP-TYPE