OMNI-gx2Rx200BX4-MIB

File: OMNI-gx2Rx200BX4-MIB.mib (132015 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC1213-MIB
RFC-1215 NLS-BBNIDENT-MIB GX2HFC-MIB
NLSBBN-TRAPS-MIB

Imported symbols

IpAddress TimeTicks Counter
OBJECT-TYPE sysUpTime DisplayString
TRAP-TYPE gi motproxies
gx2Rx200BX4 trapIdentifier trapNetworkElemModelNumber
trapNetworkElemSerialNum trapPerceivedSeverity trapNetworkElemOperState
trapNetworkElemAlarmStatus trapNetworkElemAdminState trapNetworkElemAvailStatus
trapText trapNETrapLastTrapTimeStamp trapChangedObjectId
trapChangedValueInteger trapChangedValueDisplayString

Defined Types

Float  
Counter    

U32Data  
Counter    

Gx2Rx200BX4AnalogEntry  
SEQUENCE    
  gx2Rx200BX4AnalogTableIndex INTEGER
  rx4labelOptPowerOne DisplayString Size(0..80)
  rx4uomOptPowerOne DisplayString Size(0..80)
  rx4majorHighOptPowerOne Float
  rx4majorLowOptPowerOne Float
  rx4minorHighOptPowerOne Float
  rx4minorLowOptPowerOne Float
  rx4currentValueOptPowerOne Float
  rx4stateFlagOptPowerOne INTEGER
  rx4minValueOptPowerOne Float
  rx4maxValueOptPowerOne Float
  rx4alarmStateOptPowerOne INTEGER
  rx4labelOptPowerTwo DisplayString Size(0..80)
  rx4uomOptPowerTwo DisplayString Size(0..80)
  rx4majorHighOptPowerTwo Float
  rx4majorLowOptPowerTwo Float
  rx4minorHighOptPowerTwo Float
  rx4minorLowOptPowerTwo Float
  rx4currentValueOptPowerTwo Float
  rx4stateFlagOptPowerTwo INTEGER
  rx4minValueOptPowerTwo Float
  rx4maxValueOptPowerTwo Float
  rx4alarmStateOptPowerTwo INTEGER
  rx4labelOptPowerThree DisplayString Size(0..80)
  rx4uomOptPowerThree DisplayString Size(0..80)
  rx4majorHighOptPowerThree Float
  rx4majorLowOptPowerThree Float
  rx4minorHighOptPowerThree Float
  rx4minorLowOptPowerThree Float
  rx4currentValueOptPowerThree Float
  rx4stateFlagOptPowerThree INTEGER
  rx4minValueOptPowerThree Float
  rx4maxValueOptPowerThree Float
  rx4alarmStateOptPowerThree INTEGER
  rx4labelOptPowerFour DisplayString Size(0..80)
  rx4uomOptPowerFour DisplayString Size(0..80)
  rx4majorHighOptPowerFour Float
  rx4majorLowOptPowerFour Float
  rx4minorHighOptPowerFour Float
  rx4minorLowOptPowerFour Float
  rx4currentValueOptPowerFour Float
  rx4stateFlagOptPowerFour INTEGER
  rx4minValueOptPowerFour Float
  rx4maxValueOptPowerFour Float
  rx4alarmStateOptPowerFour INTEGER
  rx4labelModTemp DisplayString Size(0..80)
  rx4uomModTemp DisplayString Size(0..80)
  rx4majorHighModTemp Float
  rx4majorLowModTemp Float
  rx4minorHighModTemp Float
  rx4minorLowModTemp Float
  rx4currentValueModTemp Float
  rx4stateFlagModTemp INTEGER
  rx4minValueModTemp Float
  rx4maxValueModTemp Float
  rx4alarmStateModTemp INTEGER
  rx4labelFanCurrent DisplayString Size(0..80)
  rx4uomFanCurrent DisplayString Size(0..80)
  rx4majorHighFanCurrent Float
  rx4majorLowFanCurrent Float
  rx4minorHighFanCurrent Float
  rx4minorLowFanCurrent Float
  rx4currentValueFanCurrent Float
  rx4stateFlagFanCurrent INTEGER
  rx4minValueFanCurrent Float
  rx4maxValueFanCurrent Float
  rx4alarmStateFanCurrent INTEGER
  rx4label12Volt DisplayString Size(0..80)
  rx4uom12Volt DisplayString Size(0..80)
  rx4majorHigh12Volt Float
  rx4majorLow12Volt Float
  rx4minorHigh12Volt Float
  rx4minorLow12Volt Float
  rx4currentValue12Volt Float
  rx4stateFlag12Volt INTEGER
  rx4minValue12Volt Float
  rx4maxValue12Volt Float
  rx4alarmState12Volt INTEGER

Gx2Rx200BX4DigitalEntry  
SEQUENCE    
  gx2Rx200BX4DigitalTableIndex INTEGER
  rx4labelModeOne DisplayString Size(0..80)
  rx4valueModeOne INTEGER
  rx4enumModeOne DisplayString Size(0..80)
  rx4stateFlagModeOne INTEGER
  rx4labelWavelengthOne DisplayString Size(0..80)
  rx4valueWavelengthOne INTEGER
  rx4enumWavelengthOne DisplayString Size(0..80)
  rx4stateFlagWavelengthOne INTEGER
  rx4labelAttnSettingOne DisplayString Size(0..80)
  rx4valueAttnSettingOne INTEGER
  rx4enumAttnSettingOne DisplayString Size(0..80)
  rx4stateFlagAttnSettingOne INTEGER
  rx4labelSwModeSettingOne DisplayString Size(0..80)
  rx4valueSwModeSettingOne INTEGER
  rx4enumSwModeSettingOne DisplayString Size(0..80)
  rx4stateFlagSwModeSettingOne INTEGER
  rx4labelSwModeThresholdOne DisplayString Size(0..80)
  rx4valueSwModeThresholdOne INTEGER
  rx4enumSwModeThresholdOne DisplayString Size(0..80)
  rx4stateFlagSwModeThresholdOne INTEGER
  rx4labelModeTwo DisplayString Size(0..80)
  rx4valueModeTwo INTEGER
  rx4enumModeTwo DisplayString Size(0..80)
  rx4stateFlagModeTwo INTEGER
  rx4labelWavelengthTwo DisplayString Size(0..80)
  rx4valueWavelengthTwo INTEGER
  rx4enumWavelengthTwo DisplayString Size(0..80)
  rx4stateFlagWavelengthTwo INTEGER
  rx4labelAttnSettingTwo DisplayString Size(0..80)
  rx4valueAttnSettingTwo INTEGER
  rx4enumAttnSettingTwo DisplayString Size(0..80)
  rx4stateFlagAttnSettingTwo INTEGER
  rx4labelSwModeSettingTwo DisplayString Size(0..80)
  rx4valueSwModeSettingTwo INTEGER
  rx4enumSwModeSettingTwo DisplayString Size(0..80)
  rx4stateFlagSwModeSettingTwo INTEGER
  rx4labelSwModeThresholdTwo DisplayString Size(0..80)
  rx4valueSwModeThresholdTwo INTEGER
  rx4enumSwModeThresholdTwo DisplayString Size(0..80)
  rx4stateFlagSwModeThresholdTwo INTEGER
  rx4labelModeThree DisplayString Size(0..80)
  rx4valueModeThree INTEGER
  rx4enumModeThree DisplayString Size(0..80)
  rx4stateFlagModeThree INTEGER
  rx4labelWavelengthThree DisplayString Size(0..80)
  rx4valueWavelengthThree INTEGER
  rx4enumWavelengthThree DisplayString Size(0..80)
  rx4stateFlagWavelengthThree INTEGER
  rx4labelAttnSettingThree DisplayString Size(0..80)
  rx4valueAttnSettingThree INTEGER
  rx4enumAttnSettingThree DisplayString Size(0..80)
  rx4stateFlagAttnSettingThree INTEGER
  rx4labelSwModeSettingThree DisplayString Size(0..80)
  rx4valueSwModeSettingThree INTEGER
  rx4enumSwModeSettingThree DisplayString Size(0..80)
  rx4stateFlagSwModeSettingThree INTEGER
  rx4labelSwModeThresholdThree DisplayString Size(0..80)
  rx4valueSwModeThresholdThree INTEGER
  rx4enumSwModeThresholdThree DisplayString Size(0..80)
  rx4stateFlagSwModeThresholdThree INTEGER
  rx4labelModeFour DisplayString Size(0..80)
  rx4valueModeFour INTEGER
  rx4enumModeFour DisplayString Size(0..80)
  rx4stateFlagModeFour INTEGER
  rx4labelWavelengthFour DisplayString Size(0..80)
  rx4valueWavelengthFour INTEGER
  rx4enumWavelengthFour DisplayString Size(0..80)
  rx4stateFlagWavelengthFour INTEGER
  rx4labelAttnSettingFour DisplayString Size(0..80)
  rx4valueAttnSettingFour INTEGER
  rx4enumAttnSettingFour DisplayString Size(0..80)
  rx4stateFlagAttnSettingFour INTEGER
  rx4labelSwModeSettingFour DisplayString Size(0..80)
  rx4valueSwModeSettingFour INTEGER
  rx4enumSwModeSettingFour DisplayString Size(0..80)
  rx4stateFlagSwModeSettingFour INTEGER
  rx4labelSwModeThresholdFour DisplayString Size(0..80)
  rx4valueSwModeThresholdFour INTEGER
  rx4enumSwModeThresholdFour DisplayString Size(0..80)
  rx4stateFlagSwModeThresholdFour INTEGER
  rx4labelModuleConfig DisplayString Size(0..80)
  rx4valueModuleConfig INTEGER
  rx4enumModuleConfig DisplayString Size(0..80)
  rx4stateFlagModuleConfig INTEGER
  rx4labelRevertTime DisplayString Size(0..80)
  rx4valueRevertTime INTEGER
  rx4enumRevertTime DisplayString Size(0..80)
  rx4stateFlagRevertTime INTEGER
  rx4labelTestPointSelect DisplayString Size(0..80)
  rx4valueTestPointSelect INTEGER
  rx4enumTestPointSelect DisplayString Size(0..80)
  rx4stateFlagTestPointSelect INTEGER
  rx4labelFactoryDefault DisplayString Size(0..80)
  rx4valueFactoryDefault INTEGER
  rx4enumFactoryDefault DisplayString Size(0..80)
  rx4stateFlagFactoryDefault INTEGER

Gx2Rx200BX4StatusEntry  
SEQUENCE    
  gx2Rx200BX4StatusTableIndex INTEGER
  rx4labelBoot DisplayString Size(0..80)
  rx4valueBoot INTEGER
  rx4stateflagBoot INTEGER
  rx4labelFlash DisplayString Size(0..80)
  rx4valueFlash INTEGER
  rx4stateflagFlash INTEGER
  rx4labelFactoryDataCRC DisplayString Size(0..80)
  rx4valueFactoryDataCRC INTEGER
  rx4stateflagFactoryDataCRC INTEGER
  rx4labelAlarmDataCRC DisplayString Size(0..80)
  rx4valueAlarmDataCRC INTEGER
  rx4stateflagAlarmDataCRC INTEGER
  rx4labelCalibrationDataCRC DisplayString Size(0..80)
  rx4valueCalibrationDataCRC INTEGER
  rx4stateflagCalibrationDataCRC INTEGER
  rx4labelHW DisplayString Size(0..80)
  rx4valueHW INTEGER
  rx4stateflagHW INTEGER
  rx4labelOptSigOne DisplayString Size(0..80)
  rx4valueOptSigOne INTEGER
  rx4stateflagOptSigOne INTEGER
  rx4labelOptSigTwo DisplayString Size(0..80)
  rx4valueOptSigTwo INTEGER
  rx4stateflagOptSigTwo INTEGER
  rx4labelOptSigThree DisplayString Size(0..80)
  rx4valueOptSigThree INTEGER
  rx4stateflagOptSigThree INTEGER
  rx4labelOptSigFour DisplayString Size(0..80)
  rx4valueOptSigFour INTEGER
  rx4stateflagOptSigFour INTEGER
  rx4labelBackupCable DisplayString Size(0..80)
  rx4valueBackupCable INTEGER
  rx4stateflagBackupCable INTEGER

Gx2Rx200BX4FactoryEntry  
SEQUENCE    
  gx2Rx200BX4FactoryTableIndex INTEGER
  rx4bootControlByte INTEGER
  rx4bootStatusByte INTEGER
  rx4bank0CRC INTEGER
  rx4bank1CRC INTEGER
  rx4prgEEPROMByte INTEGER
  rx4factoryCRC INTEGER
  rx4calculateCRC INTEGER
  rx4hourMeter INTEGER
  rx4flashPrgCntA INTEGER
  rx4flashPrgCntB INTEGER
  rx4fwRev0 DisplayString Size(0..80)
  rx4fwRev1 DisplayString Size(0..80)

Defined Values

gx2Rx200BX4Descriptor 1.3.6.1.4.1.1166.6.1.2.29.1
OBJECT IDENTIFIER    

gx2Rx200BX4AnalogTable 1.3.6.1.4.1.1166.6.1.2.29.2
This table contains gx2Rx200BX4 specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2Rx200BX4AnalogEntry

gx2Rx200BX4AnalogEntry 1.3.6.1.4.1.1166.6.1.2.29.2.1
This list contains digital product class and the associated RF channel parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2Rx200BX4AnalogEntry  

gx2Rx200BX4DigitalTable 1.3.6.1.4.1.1166.6.1.2.29.3
This table contains gx2Rx200BX4 specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2Rx200BX4DigitalEntry

gx2Rx200BX4DigitalEntry 1.3.6.1.4.1.1166.6.1.2.29.3.2
This list contains digital product class and the associated RF channel parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2Rx200BX4DigitalEntry  

gx2Rx200BX4StatusTable 1.3.6.1.4.1.1166.6.1.2.29.4
This table contains gx2Rx200BX4 specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2Rx200BX4StatusEntry

gx2Rx200BX4StatusEntry 1.3.6.1.4.1.1166.6.1.2.29.4.3
This list contains digital product class and the associated RF channel parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2Rx200BX4StatusEntry  

gx2Rx200BX4FactoryTable 1.3.6.1.4.1.1166.6.1.2.29.5
This table contains gx2Rx200BX4 specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2Rx200BX4FactoryEntry

gx2Rx200BX4FactoryEntry 1.3.6.1.4.1.1166.6.1.2.29.5.4
This list contains digital product class and the associated RF channel parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2Rx200BX4FactoryEntry  

gx2Rx200BX4AnalogTableIndex 1.3.6.1.4.1.1166.6.1.2.29.2.1.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

rx4labelOptPowerOne 1.3.6.1.4.1.1166.6.1.2.29.2.1.2
The value of this object provides the label of the Optical Power Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4uomOptPowerOne 1.3.6.1.4.1.1166.6.1.2.29.2.1.3
The value of this object provides the Unit of Measure of the Optical Power Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4majorHighOptPowerOne 1.3.6.1.4.1.1166.6.1.2.29.2.1.4
The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rx4majorLowOptPowerOne 1.3.6.1.4.1.1166.6.1.2.29.2.1.5
The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rx4minorHighOptPowerOne 1.3.6.1.4.1.1166.6.1.2.29.2.1.6
The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rx4minorLowOptPowerOne 1.3.6.1.4.1.1166.6.1.2.29.2.1.7
The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rx4currentValueOptPowerOne 1.3.6.1.4.1.1166.6.1.2.29.2.1.8
The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rx4stateFlagOptPowerOne 1.3.6.1.4.1.1166.6.1.2.29.2.1.9
The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rx4minValueOptPowerOne 1.3.6.1.4.1.1166.6.1.2.29.2.1.10
The value of this object provides the minimum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rx4maxValueOptPowerOne 1.3.6.1.4.1.1166.6.1.2.29.2.1.11
The value of this object provides the maximum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rx4alarmStateOptPowerOne 1.3.6.1.4.1.1166.6.1.2.29.2.1.12
The value of this object provides the curent alarm state of the Optical Power Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

rx4labelOptPowerTwo 1.3.6.1.4.1.1166.6.1.2.29.2.1.13
The value of this object provides the label of the Optical Power Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4uomOptPowerTwo 1.3.6.1.4.1.1166.6.1.2.29.2.1.14
The value of this object provides the Unit of Measure of the Optical Power Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4majorHighOptPowerTwo 1.3.6.1.4.1.1166.6.1.2.29.2.1.15
The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rx4majorLowOptPowerTwo 1.3.6.1.4.1.1166.6.1.2.29.2.1.16
The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rx4minorHighOptPowerTwo 1.3.6.1.4.1.1166.6.1.2.29.2.1.17
The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rx4minorLowOptPowerTwo 1.3.6.1.4.1.1166.6.1.2.29.2.1.18
The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rx4currentValueOptPowerTwo 1.3.6.1.4.1.1166.6.1.2.29.2.1.19
The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rx4stateFlagOptPowerTwo 1.3.6.1.4.1.1166.6.1.2.29.2.1.20
The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rx4minValueOptPowerTwo 1.3.6.1.4.1.1166.6.1.2.29.2.1.21
The value of this object provides the minimum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rx4maxValueOptPowerTwo 1.3.6.1.4.1.1166.6.1.2.29.2.1.22
The value of this object provides the maximum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rx4alarmStateOptPowerTwo 1.3.6.1.4.1.1166.6.1.2.29.2.1.23
The value of this object provides the curent alarm state of the Optical Power Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

rx4labelOptPowerThree 1.3.6.1.4.1.1166.6.1.2.29.2.1.24
The value of this object provides the label of the Optical Power Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4uomOptPowerThree 1.3.6.1.4.1.1166.6.1.2.29.2.1.25
The value of this object provides the Unit of Measure of the Optical Power Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4majorHighOptPowerThree 1.3.6.1.4.1.1166.6.1.2.29.2.1.26
The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rx4majorLowOptPowerThree 1.3.6.1.4.1.1166.6.1.2.29.2.1.27
The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rx4minorHighOptPowerThree 1.3.6.1.4.1.1166.6.1.2.29.2.1.28
The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rx4minorLowOptPowerThree 1.3.6.1.4.1.1166.6.1.2.29.2.1.29
The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rx4currentValueOptPowerThree 1.3.6.1.4.1.1166.6.1.2.29.2.1.30
The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rx4stateFlagOptPowerThree 1.3.6.1.4.1.1166.6.1.2.29.2.1.31
The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rx4minValueOptPowerThree 1.3.6.1.4.1.1166.6.1.2.29.2.1.32
The value of this object provides the minimum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rx4maxValueOptPowerThree 1.3.6.1.4.1.1166.6.1.2.29.2.1.33
The value of this object provides the maximum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rx4alarmStateOptPowerThree 1.3.6.1.4.1.1166.6.1.2.29.2.1.34
The value of this object provides the curent alarm state of the Optical Power Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

rx4labelOptPowerFour 1.3.6.1.4.1.1166.6.1.2.29.2.1.35
The value of this object provides the label of the Optical Power Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4uomOptPowerFour 1.3.6.1.4.1.1166.6.1.2.29.2.1.36
The value of this object provides the Unit of Measure of the Optical Power Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4majorHighOptPowerFour 1.3.6.1.4.1.1166.6.1.2.29.2.1.37
The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rx4majorLowOptPowerFour 1.3.6.1.4.1.1166.6.1.2.29.2.1.38
The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rx4minorHighOptPowerFour 1.3.6.1.4.1.1166.6.1.2.29.2.1.39
The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rx4minorLowOptPowerFour 1.3.6.1.4.1.1166.6.1.2.29.2.1.40
The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rx4currentValueOptPowerFour 1.3.6.1.4.1.1166.6.1.2.29.2.1.41
The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rx4stateFlagOptPowerFour 1.3.6.1.4.1.1166.6.1.2.29.2.1.42
The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rx4minValueOptPowerFour 1.3.6.1.4.1.1166.6.1.2.29.2.1.43
The value of this object provides the minimum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rx4maxValueOptPowerFour 1.3.6.1.4.1.1166.6.1.2.29.2.1.44
The value of this object provides the maximum value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rx4alarmStateOptPowerFour 1.3.6.1.4.1.1166.6.1.2.29.2.1.45
The value of this object provides the curent alarm state of the Optical Power Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

rx4labelModTemp 1.3.6.1.4.1.1166.6.1.2.29.2.1.46
The value of this object provides the label of the Module Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4uomModTemp 1.3.6.1.4.1.1166.6.1.2.29.2.1.47
The value of this object provides the Unit of Measure of the Module Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4majorHighModTemp 1.3.6.1.4.1.1166.6.1.2.29.2.1.48
The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rx4majorLowModTemp 1.3.6.1.4.1.1166.6.1.2.29.2.1.49
The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rx4minorHighModTemp 1.3.6.1.4.1.1166.6.1.2.29.2.1.50
The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rx4minorLowModTemp 1.3.6.1.4.1.1166.6.1.2.29.2.1.51
The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rx4currentValueModTemp 1.3.6.1.4.1.1166.6.1.2.29.2.1.52
The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rx4stateFlagModTemp 1.3.6.1.4.1.1166.6.1.2.29.2.1.53
The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rx4minValueModTemp 1.3.6.1.4.1.1166.6.1.2.29.2.1.54
The value of this object provides the minimum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rx4maxValueModTemp 1.3.6.1.4.1.1166.6.1.2.29.2.1.55
The value of this object provides the maximum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rx4alarmStateModTemp 1.3.6.1.4.1.1166.6.1.2.29.2.1.56
The value of this object provides the curent alarm state of the Module Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

rx4labelFanCurrent 1.3.6.1.4.1.1166.6.1.2.29.2.1.57
The value of this object provides the label of the Fan Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4uomFanCurrent 1.3.6.1.4.1.1166.6.1.2.29.2.1.58
The value of this object provides the Unit of Measure of the Fan Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4majorHighFanCurrent 1.3.6.1.4.1.1166.6.1.2.29.2.1.59
The value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rx4majorLowFanCurrent 1.3.6.1.4.1.1166.6.1.2.29.2.1.60
The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rx4minorHighFanCurrent 1.3.6.1.4.1.1166.6.1.2.29.2.1.61
The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rx4minorLowFanCurrent 1.3.6.1.4.1.1166.6.1.2.29.2.1.62
The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rx4currentValueFanCurrent 1.3.6.1.4.1.1166.6.1.2.29.2.1.63
The value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rx4stateFlagFanCurrent 1.3.6.1.4.1.1166.6.1.2.29.2.1.64
The value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rx4minValueFanCurrent 1.3.6.1.4.1.1166.6.1.2.29.2.1.65
The value of this object provides the minimum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rx4maxValueFanCurrent 1.3.6.1.4.1.1166.6.1.2.29.2.1.66
The value of this object provides the maximum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rx4alarmStateFanCurrent 1.3.6.1.4.1.1166.6.1.2.29.2.1.67
The value of this object provides the curent alarm state of the Fan Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

rx4label12Volt 1.3.6.1.4.1.1166.6.1.2.29.2.1.68
The value of this object provides the label of the 12v Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4uom12Volt 1.3.6.1.4.1.1166.6.1.2.29.2.1.69
The value of this object provides the Unit of Measure of the 12v Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4majorHigh12Volt 1.3.6.1.4.1.1166.6.1.2.29.2.1.70
The value of this object provides the Major High alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rx4majorLow12Volt 1.3.6.1.4.1.1166.6.1.2.29.2.1.71
The value of this object provides the Major Low alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rx4minorHigh12Volt 1.3.6.1.4.1.1166.6.1.2.29.2.1.72
The value of this object provides the Minor High alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rx4minorLow12Volt 1.3.6.1.4.1.1166.6.1.2.29.2.1.73
The value of this object provides the Minor Low alarm value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rx4currentValue12Volt 1.3.6.1.4.1.1166.6.1.2.29.2.1.74
The value of this object provides the Current value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rx4stateFlag12Volt 1.3.6.1.4.1.1166.6.1.2.29.2.1.75
The value of this object provides the state of the 12v Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rx4minValue12Volt 1.3.6.1.4.1.1166.6.1.2.29.2.1.76
The value of this object provides the minimum value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rx4maxValue12Volt 1.3.6.1.4.1.1166.6.1.2.29.2.1.77
The value of this object provides the maximum value of the 12 Volt Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rx4alarmState12Volt 1.3.6.1.4.1.1166.6.1.2.29.2.1.78
The value of this object provides the curent alarm state of the 12v Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

gx2Rx200BX4DigitalTableIndex 1.3.6.1.4.1.1166.6.1.2.29.3.2.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

rx4labelModeOne 1.3.6.1.4.1.1166.6.1.2.29.3.2.2
The value of this object provides the label of the Rx200BX4's Mode Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4enumModeOne 1.3.6.1.4.1.1166.6.1.2.29.3.2.3
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4valueModeOne 1.3.6.1.4.1.1166.6.1.2.29.3.2.4
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), manual(2), agc(3)  

rx4stateFlagModeOne 1.3.6.1.4.1.1166.6.1.2.29.3.2.5
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rx4labelWavelengthOne 1.3.6.1.4.1.1166.6.1.2.29.3.2.6
The value of this object provides the label of the Rx200BX4's Wavelength Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4enumWavelengthOne 1.3.6.1.4.1.1166.6.1.2.29.3.2.7
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4valueWavelengthOne 1.3.6.1.4.1.1166.6.1.2.29.3.2.8
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER nM1270(1), nM1290(2), nM1310(3), nM1330(4), nM1350(5), nM1370(6), nM1390(7), nM1410(8), nM1430(9), nM1450(10), nM1470(11), nM1490(12), nM1510(13), nM1530(14), nM1550(15), nM1570(16), nM1590(17), nM1610(18)  

rx4stateFlagWavelengthOne 1.3.6.1.4.1.1166.6.1.2.29.3.2.9
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rx4labelAttnSettingOne 1.3.6.1.4.1.1166.6.1.2.29.3.2.10
The value of this object provides the label of the Rx200BX4's AttnSetting Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4enumAttnSettingOne 1.3.6.1.4.1.1166.6.1.2.29.3.2.11
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4valueAttnSettingOne 1.3.6.1.4.1.1166.6.1.2.29.3.2.12
The value of this object is the current value of the parameter. It is an integer value from 0 to 40. Each increment represents 1/2 dB of attenuation from 0 to 20 dB. Where 0 = 0db and 40 = 20db
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

rx4stateFlagAttnSettingOne 1.3.6.1.4.1.1166.6.1.2.29.3.2.13
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rx4labelSwModeSettingOne 1.3.6.1.4.1.1166.6.1.2.29.3.2.14
The value of this object provides the label of the Rx200BX4's Switch Mode Setting Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4enumSwModeSettingOne 1.3.6.1.4.1.1166.6.1.2.29.3.2.15
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4valueSwModeSettingOne 1.3.6.1.4.1.1166.6.1.2.29.3.2.16
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), alarm-only(2), alarm-and-switch(3)  

rx4stateFlagSwModeSettingOne 1.3.6.1.4.1.1166.6.1.2.29.3.2.17
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rx4labelSwModeThresholdOne 1.3.6.1.4.1.1166.6.1.2.29.3.2.18
The value of this object provides the label of the Rx200BX4's Switch Mode Threshold Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4enumSwModeThresholdOne 1.3.6.1.4.1.1166.6.1.2.29.3.2.19
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4valueSwModeThresholdOne 1.3.6.1.4.1.1166.6.1.2.29.3.2.20
The value of this object reflects the setting of the threshold at which the Optical Input Failed signal is sent. It is in 1 dB increments ranging from -2 to -17 dB. The user can enter a number from 0 to 15, where 0 = -2db and 15= -17db
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

rx4stateFlagSwModeThresholdOne 1.3.6.1.4.1.1166.6.1.2.29.3.2.21
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rx4labelModeTwo 1.3.6.1.4.1.1166.6.1.2.29.3.2.22
The value of this object provides the label of the Rx200BX4's Mode Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4enumModeTwo 1.3.6.1.4.1.1166.6.1.2.29.3.2.23
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4valueModeTwo 1.3.6.1.4.1.1166.6.1.2.29.3.2.24
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), manual(2), agc(3)  

rx4stateFlagModeTwo 1.3.6.1.4.1.1166.6.1.2.29.3.2.25
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rx4labelWavelengthTwo 1.3.6.1.4.1.1166.6.1.2.29.3.2.26
The value of this object provides the label of the Rx200BX4's Wavelength Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4enumWavelengthTwo 1.3.6.1.4.1.1166.6.1.2.29.3.2.27
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4valueWavelengthTwo 1.3.6.1.4.1.1166.6.1.2.29.3.2.28
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER nM1270(1), nM1290(2), nM1310(3), nM1330(4), nM1350(5), nM1370(6), nM1390(7), nM1410(8), nM1430(9), nM1450(10), nM1470(11), nM1490(12), nM1510(13), nM1530(14), nM1550(15), nM1570(16), nM1590(17), nM1610(18)  

rx4stateFlagWavelengthTwo 1.3.6.1.4.1.1166.6.1.2.29.3.2.29
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rx4labelAttnSettingTwo 1.3.6.1.4.1.1166.6.1.2.29.3.2.30
The value of this object provides the label of the Rx200BX4's AttnSetting Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4enumAttnSettingTwo 1.3.6.1.4.1.1166.6.1.2.29.3.2.31
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4valueAttnSettingTwo 1.3.6.1.4.1.1166.6.1.2.29.3.2.32
The value of this object is the current value of the parameter. It is an integer value from 0 to 40. Each increment represents 1/2 dB of attenuation from 0 to 20 dB. Where 0 = 0db and 40 = 20db
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

rx4stateFlagAttnSettingTwo 1.3.6.1.4.1.1166.6.1.2.29.3.2.33
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rx4labelSwModeSettingTwo 1.3.6.1.4.1.1166.6.1.2.29.3.2.34
The value of this object provides the label of the Rx200BX4's Switch Mode Setting Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4enumSwModeSettingTwo 1.3.6.1.4.1.1166.6.1.2.29.3.2.35
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4valueSwModeSettingTwo 1.3.6.1.4.1.1166.6.1.2.29.3.2.36
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), alarm-only(2), alarm-and-switch(3)  

rx4stateFlagSwModeSettingTwo 1.3.6.1.4.1.1166.6.1.2.29.3.2.37
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rx4labelSwModeThresholdTwo 1.3.6.1.4.1.1166.6.1.2.29.3.2.38
The value of this object provides the label of the Rx200BX4's Switch Mode Threshold Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4enumSwModeThresholdTwo 1.3.6.1.4.1.1166.6.1.2.29.3.2.39
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4valueSwModeThresholdTwo 1.3.6.1.4.1.1166.6.1.2.29.3.2.40
The value of this object reflects the setting of the threshold at which the Optical Input Failed signal is sent. It is in 1 dB increments ranging from -2 to -17 dB. The user can enter a number from 0 to 15, where 0 = -2db and 15= -17db
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

rx4stateFlagSwModeThresholdTwo 1.3.6.1.4.1.1166.6.1.2.29.3.2.41
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rx4labelModeThree 1.3.6.1.4.1.1166.6.1.2.29.3.2.42
The value of this object provides the label of the Rx200BX4's Mode Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4enumModeThree 1.3.6.1.4.1.1166.6.1.2.29.3.2.43
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4valueModeThree 1.3.6.1.4.1.1166.6.1.2.29.3.2.44
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), manual(2), agc(3)  

rx4stateFlagModeThree 1.3.6.1.4.1.1166.6.1.2.29.3.2.45
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rx4labelWavelengthThree 1.3.6.1.4.1.1166.6.1.2.29.3.2.46
The value of this object provides the label of the Rx200BX4's Wavelength Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4enumWavelengthThree 1.3.6.1.4.1.1166.6.1.2.29.3.2.47
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4valueWavelengthThree 1.3.6.1.4.1.1166.6.1.2.29.3.2.48
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER nM1270(1), nM1290(2), nM1310(3), nM1330(4), nM1350(5), nM1370(6), nM1390(7), nM1410(8), nM1430(9), nM1450(10), nM1470(11), nM1490(12), nM1510(13), nM1530(14), nM1550(15), nM1570(16), nM1590(17), nM1610(18)  

rx4stateFlagWavelengthThree 1.3.6.1.4.1.1166.6.1.2.29.3.2.49
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rx4labelAttnSettingThree 1.3.6.1.4.1.1166.6.1.2.29.3.2.50
The value of this object provides the label of the Rx200BX4's AttnSetting Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4enumAttnSettingThree 1.3.6.1.4.1.1166.6.1.2.29.3.2.51
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4valueAttnSettingThree 1.3.6.1.4.1.1166.6.1.2.29.3.2.52
The value of this object is the current value of the parameter. It is an integer value from 0 to 40. Each increment represents 1/2 dB of attenuation from 0 to 20 dB. Where 0 = 0db and 40 = 20db
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

rx4stateFlagAttnSettingThree 1.3.6.1.4.1.1166.6.1.2.29.3.2.53
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rx4labelSwModeSettingThree 1.3.6.1.4.1.1166.6.1.2.29.3.2.54
The value of this object provides the label of the Rx200BX4's Switch Mode Setting Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4enumSwModeSettingThree 1.3.6.1.4.1.1166.6.1.2.29.3.2.55
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4valueSwModeSettingThree 1.3.6.1.4.1.1166.6.1.2.29.3.2.56
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), alarm-only(2), alarm-and-switch(3)  

rx4stateFlagSwModeSettingThree 1.3.6.1.4.1.1166.6.1.2.29.3.2.57
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rx4labelSwModeThresholdThree 1.3.6.1.4.1.1166.6.1.2.29.3.2.58
The value of this object provides the label of the Rx200BX4's Switch Mode Threshold Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4enumSwModeThresholdThree 1.3.6.1.4.1.1166.6.1.2.29.3.2.59
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4valueSwModeThresholdThree 1.3.6.1.4.1.1166.6.1.2.29.3.2.60
The value of this object reflects the setting of the threshold at which the Optical Input Failed signal is sent. It is in 1 dB increments ranging from -2 to -17 dB. The user can enter a number from 0 to 15, where 0 = -2db and 15= -17db
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

rx4stateFlagSwModeThresholdThree 1.3.6.1.4.1.1166.6.1.2.29.3.2.61
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rx4labelModeFour 1.3.6.1.4.1.1166.6.1.2.29.3.2.62
The value of this object provides the label of the Rx200BX4's Mode Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4enumModeFour 1.3.6.1.4.1.1166.6.1.2.29.3.2.63
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4valueModeFour 1.3.6.1.4.1.1166.6.1.2.29.3.2.64
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), manual(2), agc(3)  

rx4stateFlagModeFour 1.3.6.1.4.1.1166.6.1.2.29.3.2.65
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rx4labelWavelengthFour 1.3.6.1.4.1.1166.6.1.2.29.3.2.66
The value of this object provides the label of the Rx200BX4's Wavelength Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4enumWavelengthFour 1.3.6.1.4.1.1166.6.1.2.29.3.2.67
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4valueWavelengthFour 1.3.6.1.4.1.1166.6.1.2.29.3.2.68
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER nM1270(1), nM1290(2), nM1310(3), nM1330(4), nM1350(5), nM1370(6), nM1390(7), nM1410(8), nM1430(9), nM1450(10), nM1470(11), nM1490(12), nM1510(13), nM1530(14), nM1550(15), nM1570(16), nM1590(17), nM1610(18)  

rx4stateFlagWavelengthFour 1.3.6.1.4.1.1166.6.1.2.29.3.2.69
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rx4labelAttnSettingFour 1.3.6.1.4.1.1166.6.1.2.29.3.2.70
The value of this object provides the label of the Rx200BX4's AttnSetting Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4enumAttnSettingFour 1.3.6.1.4.1.1166.6.1.2.29.3.2.71
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4valueAttnSettingFour 1.3.6.1.4.1.1166.6.1.2.29.3.2.72
The value of this object is the current value of the parameter. It is an integer value from 0 to 40. Each increment represents 1/2 dB of attenuation from 0 to 20 dB. Where 0 = 0db and 40 = 20db
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

rx4stateFlagAttnSettingFour 1.3.6.1.4.1.1166.6.1.2.29.3.2.73
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rx4labelSwModeSettingFour 1.3.6.1.4.1.1166.6.1.2.29.3.2.74
The value of this object provides the label of the Rx200BX4's Switch Mode Setting Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4enumSwModeSettingFour 1.3.6.1.4.1.1166.6.1.2.29.3.2.75
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4valueSwModeSettingFour 1.3.6.1.4.1.1166.6.1.2.29.3.2.76
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), alarm-only(2), alarm-and-switch(3)  

rx4stateFlagSwModeSettingFour 1.3.6.1.4.1.1166.6.1.2.29.3.2.77
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rx4labelSwModeThresholdFour 1.3.6.1.4.1.1166.6.1.2.29.3.2.78
The value of this object provides the label of the Rx200BX4's Switch Mode Threshold Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4enumSwModeThresholdFour 1.3.6.1.4.1.1166.6.1.2.29.3.2.79
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4valueSwModeThresholdFour 1.3.6.1.4.1.1166.6.1.2.29.3.2.80
The value of this object reflects the setting of the threshold at which the Optical Input Failed signal is sent. It is in 1 dB increments ranging from -2 to -17 dB. The user can enter a number from 0 to 15, where 0 = -2db and 15= -17db
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

rx4stateFlagSwModeThresholdFour 1.3.6.1.4.1.1166.6.1.2.29.3.2.81
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rx4labelModuleConfig 1.3.6.1.4.1.1166.6.1.2.29.3.2.82
The value of this object provides the label of the Factory Default Reset Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4enumModuleConfig 1.3.6.1.4.1.1166.6.1.2.29.3.2.83
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4valueModuleConfig 1.3.6.1.4.1.1166.6.1.2.29.3.2.84
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER slave(1), master(2), burst(3)  

rx4stateFlagModuleConfig 1.3.6.1.4.1.1166.6.1.2.29.3.2.85
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rx4labelRevertTime 1.3.6.1.4.1.1166.6.1.2.29.3.2.86
The value of this object provides the label of the Factory Default Reset Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4enumRevertTime 1.3.6.1.4.1.1166.6.1.2.29.3.2.87
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4valueRevertTime 1.3.6.1.4.1.1166.6.1.2.29.3.2.88
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER one-sec(1), ten-sec(2), sixty-sec(3), six-hundred-sec(4)  

rx4stateFlagRevertTime 1.3.6.1.4.1.1166.6.1.2.29.3.2.89
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rx4labelTestPointSelect 1.3.6.1.4.1.1166.6.1.2.29.3.2.90
The value of this object provides the label of the Test point Select Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4enumTestPointSelect 1.3.6.1.4.1.1166.6.1.2.29.3.2.91
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4valueTestPointSelect 1.3.6.1.4.1.1166.6.1.2.29.3.2.92
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER one(1), two(2), three(3), four(4)  

rx4stateFlagTestPointSelect 1.3.6.1.4.1.1166.6.1.2.29.3.2.93
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rx4labelFactoryDefault 1.3.6.1.4.1.1166.6.1.2.29.3.2.94
The value of this object provides the label of the Factory Default Reset Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4enumFactoryDefault 1.3.6.1.4.1.1166.6.1.2.29.3.2.95
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4valueFactoryDefault 1.3.6.1.4.1.1166.6.1.2.29.3.2.96
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

rx4stateFlagFactoryDefault 1.3.6.1.4.1.1166.6.1.2.29.3.2.97
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

gx2Rx200BX4StatusTableIndex 1.3.6.1.4.1.1166.6.1.2.29.4.3.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

rx4labelBoot 1.3.6.1.4.1.1166.6.1.2.29.4.3.2
The value of this object provides the label of the Boot Status Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4valueBoot 1.3.6.1.4.1.1166.6.1.2.29.4.3.3
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

rx4stateflagBoot 1.3.6.1.4.1.1166.6.1.2.29.4.3.4
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rx4labelFlash 1.3.6.1.4.1.1166.6.1.2.29.4.3.5
The value of this object provides the label of the Flash Status Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4valueFlash 1.3.6.1.4.1.1166.6.1.2.29.4.3.6
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

rx4stateflagFlash 1.3.6.1.4.1.1166.6.1.2.29.4.3.7
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rx4labelFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.29.4.3.8
The value of this object provides the label of the Factory Data CRC Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4valueFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.29.4.3.9
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

rx4stateflagFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.29.4.3.10
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rx4labelAlarmDataCRC 1.3.6.1.4.1.1166.6.1.2.29.4.3.11
The value of this object provides the label of the Alarm Data CRC Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4valueAlarmDataCRC 1.3.6.1.4.1.1166.6.1.2.29.4.3.12
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

rx4stateflagAlarmDataCRC 1.3.6.1.4.1.1166.6.1.2.29.4.3.13
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rx4labelCalibrationDataCRC 1.3.6.1.4.1.1166.6.1.2.29.4.3.14
The value of this object provides the label of the Calibration Data CRC Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4valueCalibrationDataCRC 1.3.6.1.4.1.1166.6.1.2.29.4.3.15
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

rx4stateflagCalibrationDataCRC 1.3.6.1.4.1.1166.6.1.2.29.4.3.16
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rx4labelHW 1.3.6.1.4.1.1166.6.1.2.29.4.3.17
The value of this object provides the label of the Hardware Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4valueHW 1.3.6.1.4.1.1166.6.1.2.29.4.3.18
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

rx4stateflagHW 1.3.6.1.4.1.1166.6.1.2.29.4.3.19
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rx4labelOptSigOne 1.3.6.1.4.1.1166.6.1.2.29.4.3.20
The value of this object provides the label of the Optical Signal Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4valueOptSigOne 1.3.6.1.4.1.1166.6.1.2.29.4.3.21
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

rx4stateflagOptSigOne 1.3.6.1.4.1.1166.6.1.2.29.4.3.22
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rx4labelOptSigTwo 1.3.6.1.4.1.1166.6.1.2.29.4.3.23
The value of this object provides the label of the Optical Signal Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4valueOptSigTwo 1.3.6.1.4.1.1166.6.1.2.29.4.3.24
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

rx4stateflagOptSigTwo 1.3.6.1.4.1.1166.6.1.2.29.4.3.25
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rx4labelOptSigThree 1.3.6.1.4.1.1166.6.1.2.29.4.3.26
The value of this object provides the label of the Optical Signal Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4valueOptSigThree 1.3.6.1.4.1.1166.6.1.2.29.4.3.27
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

rx4stateflagOptSigThree 1.3.6.1.4.1.1166.6.1.2.29.4.3.28
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rx4labelOptSigFour 1.3.6.1.4.1.1166.6.1.2.29.4.3.29
The value of this object provides the label of the Optical Signal Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4valueOptSigFour 1.3.6.1.4.1.1166.6.1.2.29.4.3.30
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

rx4stateflagOptSigFour 1.3.6.1.4.1.1166.6.1.2.29.4.3.31
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rx4labelBackupCable 1.3.6.1.4.1.1166.6.1.2.29.4.3.32
The value of this object provides the label of the Backup Cable Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4valueBackupCable 1.3.6.1.4.1.1166.6.1.2.29.4.3.33
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

rx4stateflagBackupCable 1.3.6.1.4.1.1166.6.1.2.29.4.3.34
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

gx2Rx200BX4FactoryTableIndex 1.3.6.1.4.1.1166.6.1.2.29.5.4.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

rx4bootControlByte 1.3.6.1.4.1.1166.6.1.2.29.5.4.2
The value of this object indicates which bank the firmware is currently being boot from.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rx4bootStatusByte 1.3.6.1.4.1.1166.6.1.2.29.5.4.3
This object indicates the status of the last boot
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rx4bank0CRC 1.3.6.1.4.1.1166.6.1.2.29.5.4.4
This object provides the CRC code of bank 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rx4bank1CRC 1.3.6.1.4.1.1166.6.1.2.29.5.4.5
This object provides the CRC code of bank 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rx4prgEEPROMByte 1.3.6.1.4.1.1166.6.1.2.29.5.4.6
This object indicates if the EEPROM has been programmed
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rx4factoryCRC 1.3.6.1.4.1.1166.6.1.2.29.5.4.7
This object provides the CRC code for the Factory data.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rx4calculateCRC 1.3.6.1.4.1.1166.6.1.2.29.5.4.8
This object indicates which of the Emnums will have the CRC calculated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER factory(1), calibration(2), alarm(3), tempComp(4)  

rx4hourMeter 1.3.6.1.4.1.1166.6.1.2.29.5.4.9
This object provides the hour meter reading of the module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rx4flashPrgCntA 1.3.6.1.4.1.1166.6.1.2.29.5.4.10
This object provides the number of times the flash has been programmed on side A.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rx4flashPrgCntB 1.3.6.1.4.1.1166.6.1.2.29.5.4.11
This object provides the number of times the flash has been programmed on side B.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rx4fwRev0 1.3.6.1.4.1.1166.6.1.2.29.5.4.12
This object provides the Revision of the firmware stores in bank 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rx4fwRev1 1.3.6.1.4.1.1166.6.1.2.29.5.4.13
This object provides the Revision of the firmware stores in bank 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

trapRx200BX4ConfigChangeInteger 1
This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE    

trapRx200BX4ConfigChangeDisplayString 2
This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE    

trapRx200BX4OpticalPower1Alarm 3
This trap is issued when the Receiver's channel 1 Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapRx200BX4OpticalPower2Alarm 4
This trap is issued when the Receiver's channel 2 Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapRx200BX4OpticalPower3Alarm 5
This trap is issued when the Receiver's channel 3 Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapRx200BX4OpticalPower4Alarm 6
This trap is issued when the Receiver's channel 4 Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapRx200BX4ModuleTemperatureAlarm 7
This trap is issued when the Rx200BX4 Modules Temperature goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapRx200BX4FanCurrentAlarm 8
This trap is issued when the Rx200BX4 Modules Fan Currrent parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapRx200BX4Plus12CurrentAlarm 9
This trap is issued when the Rx200BX4 Modules positive 12 volt current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapRx200BX4Boot0Alarm 10
This trap is issued when the Rx200BX4 Modules Bank 0 Boot sequence has detected an error. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapRx200BX4Boot1Alarm 11
This trap is issued when the Rx200BX4 Modules Bank 1 Boot sequence has detected an error. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapRx200BX4FlashAlarm 12
This trap is issued when the Rx200BX4 Modules boot or flash programming sequence has detected a Flash error. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapRx200BX4AlarmDataCRCAlarm 13
This trap is issued when the Rx200BX4 Module detects an error calculating the alarm limit CRC. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapRx200BX4FactoryDataCRCAlarm 14
This trap is issued when the Rx200BX4 Module detects an error calculating the Factory data CRC. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapRx200BX4CalDataCRCAlarm 15
This trap is issued when the Rx200BX4 Module detects an error calculating the Calibration data CRC. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapRx200BX4DefaultAlarm 16
This trap is issued when the Rx200BX4 Module is reset to it's factory default state. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapRx200BX4Mode1Alarm 17
This trap is issued when the Rx200BX4 Modules receiver 1 mode is changed from manual or AGC to off and back. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapRx200BX4Mode2Alarm 18
This trap is issued when the Rx200BX4 Modules receiver 1 mode is changed from manual or AGC to off and back. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapRx200BX4Mode3Alarm 19
This trap is issued when the Rx200BX4 Modules receiver 1 mode is changed from manual or AGC to off and back. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapRx200BX4Mode4Alarm 20
This trap is issued when the Rx200BX4 Modules receiver 1 mode is changed from manual or AGC to off and back. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapRx200BX4Output1SwitchedAlarm 21
This trap is issued when the Rx200BX4 Module's receiver 1 output to the RF Switch Module changes state from good to bad or bad to good. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapRx200BX4Output2SwitchedAlarm 22
This trap is issued when the Rx200BX4 Module's receiver 2 output to the RF Switch Module changes state from good to bad or bad to good. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapRx200BX4Output3SwitchedAlarm 23
This trap is issued when the Rx200BX4 Module's receiver 3 output to the RF Switch Module changes state from good to bad or bad to good. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapRx200BX4Output4SwitchedAlarm 24
This trap is issued when the Rx200BX4 Module's receiver 4 output to the RF Switch Module changes state from good to bad or bad to good. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapRx200BX4RX1StatusAlarm 25
This trap is issued when receiver 1 of the Rx200BX4 Module output is turned on or off.
TRAP-TYPE    

trapRx200BX4RX2StatusAlarm 26
This trap is issued when receiver 2 of the Rx200BX4 Module output is turned on or off.
TRAP-TYPE    

trapRx200BX4RX3StatusAlarm 27
This trap is issued when receiver 3 of the Rx200BX4 Module output is turned on or off.
TRAP-TYPE    

trapRx200BX4RX4StatusAlarm 28
This trap is issued when receiver 4 of the Rx200BX4 Module output is turned on or off.
TRAP-TYPE    

trapRx200BX4BackupCableAlarm 29
This trap is issued when the slave receiver loses connection to the master receiver.
TRAP-TYPE    

trapRx200BX4OptPwr1BadAlarm 30
This trap is issued when the receiver 1 optical power level falls below the user set switching threshold.
TRAP-TYPE    

trapRx200BX4OptPwr2BadAlarm 31
This trap is issued when the receiver 2 optical power level falls below the user set switching threshold.
TRAP-TYPE    

trapRx200BX4OptPwr3BadAlarm 32
This trap is issued when the receiver 3 optical power level falls below the user set switching threshold.
TRAP-TYPE    

trapRx200BX4OptPwr4BadAlarm 33
This trap is issued when the receiver 4 optical power level falls below the user set switching threshold.
TRAP-TYPE