OMNI-gx2RFA1000-MIB

File: OMNI-gx2RFA1000-MIB.mib (52524 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC1213-MIB
RFC-1215 GX2HFC-MIB NLSBBN-TRAPS-MIB

Imported symbols

IpAddress TimeTicks Counter
OBJECT-TYPE DisplayString TRAP-TYPE
gx2Rfa1000 trapIdentifier trapNetworkElemModelNumber
trapNetworkElemSerialNum trapPerceivedSeverity trapNetworkElemOperState
trapNetworkElemAlarmStatus trapNetworkElemAdminState trapNetworkElemAvailStatus
trapText trapNETrapLastTrapTimeStamp trapChangedObjectId
trapChangedValueInteger trapChangedValueDisplayString

Defined Types

Float  
Counter    

Gx2Rfa1000AnalogEntry  
SEQUENCE    
  rfagx2Rfa1000AnalogTableIndex INTEGER
  rfalabelModTemp DisplayString Size(0..80)
  rfauomModTemp DisplayString Size(0..80)
  rfamajorHighModTemp Float
  rfamajorLowModTemp Float
  rfaminorHighModTemp Float
  rfaminorLowModTemp Float
  rfacurrentValueModTemp Float
  rfastateFlagModTemp INTEGER
  rfaminValueModTemp Float
  rfamaxValueModTemp Float
  rfaalarmStateModTemp INTEGER
  rfalabelFanCurrent DisplayString Size(0..80)
  rfauomFanCurrent DisplayString Size(0..80)
  rfamajorHighFanCurrent Float
  rfamajorLowFanCurrent Float
  rfaminorHighFanCurrent Float
  rfaminorLowFanCurrent Float
  rfacurrentValueFanCurrent Float
  rfastateFlagFanCurrent INTEGER
  rfaminValueFanCurrent Float
  rfamaxValueFanCurrent Float
  rfaalarmStateFanCurrent INTEGER
  rfalabel12Volt DisplayString Size(0..80)
  rfauom12Volt DisplayString Size(0..80)
  rfamajorHigh12Volt Float
  rfamajorLow12Volt Float
  rfaminorHigh12Volt Float
  rfaminorLow12Volt Float
  rfacurrentValue12Volt Float
  rfastateFlag12Volt INTEGER
  rfaminValue12Volt Float
  rfamaxValue12Volt Float
  rfaalarmState12Volt INTEGER

Gx2Rfa1000DigitalEntry  
SEQUENCE    
  rfagx2Rfa1000DigitalTableIndex INTEGER
  rfalabelSlopeSetting DisplayString Size(0..80)
  rfavalueSlopeSetting INTEGER
  rfaenumSlopeSetting DisplayString Size(0..80)
  rfastateFlagSlopeSetting INTEGER
  rfalabelAttnSetting DisplayString Size(0..80)
  rfavalueAttnSetting INTEGER
  rfaenumAttnSetting DisplayString Size(0..80)
  rfastateFlagAttnSetting INTEGER
  rfalabelFactoryDefault DisplayString Size(0..80)
  rfavalueFactoryDefault INTEGER
  rfaenumFactoryDefault DisplayString Size(0..80)
  rfastateFlagFactoryDefault INTEGER

Gx2Rfa1000StatusEntry  
SEQUENCE    
  rfagx2Rfa1000StatusTableIndex INTEGER
  rfalabelBoot DisplayString Size(0..80)
  rfavalueBoot INTEGER
  rfastateflagBoot INTEGER
  rfalabelFlash DisplayString Size(0..80)
  rfavalueFlash INTEGER
  rfastateflagFlash INTEGER
  rfalabelFactoryDataCRC DisplayString Size(0..80)
  rfavalueFactoryDataCRC INTEGER
  rfastateflagFactoryDataCRC INTEGER
  rfalabelAlarmDataCRC DisplayString Size(0..80)
  rfavalueAlarmDataCRC INTEGER
  rfastateflagAlarmDataCRC INTEGER
  rfalabelSlopeCalDataCRC DisplayString Size(0..80)
  rfavalueSlopeCalDataCRC INTEGER
  rfastateflagSlopeCalDataCRC INTEGER
  rfalabelAttnCalDataCRC DisplayString Size(0..80)
  rfavalueAttnCalDataCRC INTEGER
  rfastateflagAttnCalDataCRC INTEGER

Gx2Rfa1000FactoryEntry  
SEQUENCE    
  rfagx2Rfa1000FactoryTableIndex INTEGER
  rfabootControlByte INTEGER
  rfabootStatusByte INTEGER
  rfabank0CRC INTEGER
  rfabank1CRC INTEGER
  rfaprgEEPROMByte INTEGER
  rfafactoryCRC INTEGER
  rfacalculateCRC INTEGER
  rfahourMeter INTEGER
  rfaflashPrgCntA INTEGER
  rfaflashPrgCntB INTEGER
  rfafwRev0 DisplayString Size(0..80)
  rfafwRev1 DisplayString Size(0..80)

Gx2Rfa1000HoldTimeEntry  
SEQUENCE    
  gx2Rfa1000HoldTimeTableIndex INTEGER
  gx2Rfa1000HoldTimeSpecIndex INTEGER
  gx2Rfa1000HoldTimeData INTEGER

Defined Values

gx2Rfa1000Descriptor 1.3.6.1.4.1.1166.6.1.2.22.1
OBJECT IDENTIFIER    

gx2Rfa1000AnalogTable 1.3.6.1.4.1.1166.6.1.2.22.2
This table contains gx2Rfa1000 specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2Rfa1000AnalogEntry

gx2Rfa1000AnalogEntry 1.3.6.1.4.1.1166.6.1.2.22.2.1
This list contains digital product class and the associated RF channel parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2Rfa1000AnalogEntry  

gx2Rfa1000DigitalTable 1.3.6.1.4.1.1166.6.1.2.22.3
This table contains gx2Rfa1000 specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2Rfa1000DigitalEntry

gx2Rfa1000DigitalEntry 1.3.6.1.4.1.1166.6.1.2.22.3.2
This list contains digital product class and the associated RF channel parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2Rfa1000DigitalEntry  

gx2Rfa1000StatusTable 1.3.6.1.4.1.1166.6.1.2.22.4
This table contains gx2Rfa1000 specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2Rfa1000StatusEntry

gx2Rfa1000StatusEntry 1.3.6.1.4.1.1166.6.1.2.22.4.3
This list contains digital product class and the associated RF channel parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2Rfa1000StatusEntry  

gx2Rfa1000FactoryTable 1.3.6.1.4.1.1166.6.1.2.22.5
This table contains gx2Rfa1000 specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2Rfa1000FactoryEntry

gx2Rfa1000FactoryEntry 1.3.6.1.4.1.1166.6.1.2.22.5.4
This list contains digital product class and the associated RF channel parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2Rfa1000FactoryEntry  

gx2Rfa1000HoldTimeTable 1.3.6.1.4.1.1166.6.1.2.22.6
This table contains gx2Rfa1000 specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2Rfa1000HoldTimeEntry

gx2Rfa1000HoldTimeEntry 1.3.6.1.4.1.1166.6.1.2.22.6.5
This list contains digital product class and the associated RF channel parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2Rfa1000HoldTimeEntry  

rfagx2Rfa1000AnalogTableIndex 1.3.6.1.4.1.1166.6.1.2.22.2.1.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

rfalabelModTemp 1.3.6.1.4.1.1166.6.1.2.22.2.1.2
The value of this object provides the label of the Module Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rfauomModTemp 1.3.6.1.4.1.1166.6.1.2.22.2.1.3
The value of this object provides the Unit of Measure of the Module Temperature Analog parameter. The unit of measure for this parameter is Degrees C
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rfamajorHighModTemp 1.3.6.1.4.1.1166.6.1.2.22.2.1.4
The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rfamajorLowModTemp 1.3.6.1.4.1.1166.6.1.2.22.2.1.5
The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rfaminorHighModTemp 1.3.6.1.4.1.1166.6.1.2.22.2.1.6
The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rfaminorLowModTemp 1.3.6.1.4.1.1166.6.1.2.22.2.1.7
The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rfacurrentValueModTemp 1.3.6.1.4.1.1166.6.1.2.22.2.1.8
The value of this object provides the Current value of the Module Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rfastateFlagModTemp 1.3.6.1.4.1.1166.6.1.2.22.2.1.9
The value of this object provides the state of the Module Temperature Analog parameter. (1-hidden 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rfaminValueModTemp 1.3.6.1.4.1.1166.6.1.2.22.2.1.10
The value of this object provides the minimum value of the Module Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rfamaxValueModTemp 1.3.6.1.4.1.1166.6.1.2.22.2.1.11
The value of this object provides the maximum value of the Module Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rfaalarmStateModTemp 1.3.6.1.4.1.1166.6.1.2.22.2.1.12
The value of this object provides the curent alarm state of the Module Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

rfalabelFanCurrent 1.3.6.1.4.1.1166.6.1.2.22.2.1.13
The value of this object provides the label of the Fan Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rfauomFanCurrent 1.3.6.1.4.1.1166.6.1.2.22.2.1.14
The value of this object provides the Unit of Measure of the Fan Current Analog parameter. The unit of measure for this parameter is mA
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rfamajorHighFanCurrent 1.3.6.1.4.1.1166.6.1.2.22.2.1.15
The value of this object provides the Major High alarm value of the Fan Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rfamajorLowFanCurrent 1.3.6.1.4.1.1166.6.1.2.22.2.1.16
The value of this object provides the Major Low alarm value of the Fan Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rfaminorHighFanCurrent 1.3.6.1.4.1.1166.6.1.2.22.2.1.17
The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

rfaminorLowFanCurrent 1.3.6.1.4.1.1166.6.1.2.22.2.1.18
The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence
Status: obsolete Access: read-only
OBJECT-TYPE    
  Float  

rfacurrentValueFanCurrent 1.3.6.1.4.1.1166.6.1.2.22.2.1.19
The value of this object provides the Current value of the Fan Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rfastateFlagFanCurrent 1.3.6.1.4.1.1166.6.1.2.22.2.1.20
The value of this object provides the state of the Fan Current Analog parameter. (1-hidden 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rfaminValueFanCurrent 1.3.6.1.4.1.1166.6.1.2.22.2.1.21
The value of this object provides the minimum value of the Fan Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rfamaxValueFanCurrent 1.3.6.1.4.1.1166.6.1.2.22.2.1.22
The value of this object provides the maximum value of the Fan Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rfaalarmStateFanCurrent 1.3.6.1.4.1.1166.6.1.2.22.2.1.23
The value of this object provides the curent alarm state of the Fan Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

rfalabel12Volt 1.3.6.1.4.1.1166.6.1.2.22.2.1.24
The value of this object provides the label of the 12v Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rfauom12Volt 1.3.6.1.4.1.1166.6.1.2.22.2.1.25
The value of this object provides the Unit of Measure of the 12v Current Analog parameter. The unit of measure for this parameter is mA
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rfamajorHigh12Volt 1.3.6.1.4.1.1166.6.1.2.22.2.1.26
The value of this object provides the Major High alarm value of the 12 Volt Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rfamajorLow12Volt 1.3.6.1.4.1.1166.6.1.2.22.2.1.27
The value of this object provides the Major Low alarm value of the 12 Volt Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rfaminorHigh12Volt 1.3.6.1.4.1.1166.6.1.2.22.2.1.28
The value of this object provides the Minor High alarm value of the 12 Volt Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rfaminorLow12Volt 1.3.6.1.4.1.1166.6.1.2.22.2.1.29
The value of this object provides the Minor Low alarm value of the 12 Volt Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rfacurrentValue12Volt 1.3.6.1.4.1.1166.6.1.2.22.2.1.30
The value of this object provides the Current value of the 12 Volt Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rfastateFlag12Volt 1.3.6.1.4.1.1166.6.1.2.22.2.1.31
The value of this object provides the state of the 12v Current Analog parameter. (1-hidden 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rfaminValue12Volt 1.3.6.1.4.1.1166.6.1.2.22.2.1.32
The value of this object provides the minimum value of the 12 Volt Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rfamaxValue12Volt 1.3.6.1.4.1.1166.6.1.2.22.2.1.33
The value of this object provides the maximum value of the 12 Volt Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

rfaalarmState12Volt 1.3.6.1.4.1.1166.6.1.2.22.2.1.34
The value of this object provides the curent alarm state of the 12v Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

rfagx2Rfa1000DigitalTableIndex 1.3.6.1.4.1.1166.6.1.2.22.3.2.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

rfalabelSlopeSetting 1.3.6.1.4.1.1166.6.1.2.22.3.2.2
The value of this object provides the label of the RX1000's AttnSetting Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rfaenumSlopeSetting 1.3.6.1.4.1.1166.6.1.2.22.3.2.3
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 0.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rfavalueSlopeSetting 1.3.6.1.4.1.1166.6.1.2.22.3.2.4
The value of this object is the current value of the parameter. It is an integer value from 1 to 7. Each increment represents 1/2 dB of slope from 1 to 4 dB. Where 1 = 1db and 7 = 4db
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER db1point0(1), db1point5(2), db2point0(3), db2point5(4), db3point0(5), db3point5(6), db4point0(7)  

rfastateFlagSlopeSetting 1.3.6.1.4.1.1166.6.1.2.22.3.2.5
The value of this object provides the state of the the parameter. (1-hidden 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rfalabelAttnSetting 1.3.6.1.4.1.1166.6.1.2.22.3.2.6
The value of this object provides the label of the RX1000's AttnSetting Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rfaenumAttnSetting 1.3.6.1.4.1.1166.6.1.2.22.3.2.7
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 0.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rfavalueAttnSetting 1.3.6.1.4.1.1166.6.1.2.22.3.2.8
The value of this object is the current value of the parameter. It is an integer value from 1to 21 Each increment represents 1/4 dB of attenuation from 0 to 5 dB. Where 1 = 0db and 21 = 5db
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER db0point00(1), db0point25(2), db0point50(3), db0point75(4), db1point00(5), db1point25(6), db1point50(7), db1point75(8), db2point00(9), db2point25(10), db2point50(11), db2point75(12), db3point00(13), db3point25(14), db3point50(15), db3point75(16), db4point00(17), db4point25(18), db4point50(19), db4point75(20), db5point00(21)  

rfastateFlagAttnSetting 1.3.6.1.4.1.1166.6.1.2.22.3.2.9
The value of this object provides the state of the the parameter. (1-hidden 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rfalabelFactoryDefault 1.3.6.1.4.1.1166.6.1.2.22.3.2.10
The value of this object provides the label of the Factory Default Reset Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rfaenumFactoryDefault 1.3.6.1.4.1.1166.6.1.2.22.3.2.11
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rfavalueFactoryDefault 1.3.6.1.4.1.1166.6.1.2.22.3.2.12
The value of this object is the current value of the parameter.This parameter will always read off(1)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

rfastateFlagFactoryDefault 1.3.6.1.4.1.1166.6.1.2.22.3.2.13
The value of this object provides the state of the the parameter. (1-hidden 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rfagx2Rfa1000StatusTableIndex 1.3.6.1.4.1.1166.6.1.2.22.4.3.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

rfalabelBoot 1.3.6.1.4.1.1166.6.1.2.22.4.3.2
The value of this object provides the label of the Boot Status Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rfavalueBoot 1.3.6.1.4.1.1166.6.1.2.22.4.3.3
The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

rfastateflagBoot 1.3.6.1.4.1.1166.6.1.2.22.4.3.4
The value of this object provides the state of the the parameter. (1-hidden 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rfalabelFlash 1.3.6.1.4.1.1166.6.1.2.22.4.3.5
The value of this object provides the label of the Flash Status Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rfavalueFlash 1.3.6.1.4.1.1166.6.1.2.22.4.3.6
The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

rfastateflagFlash 1.3.6.1.4.1.1166.6.1.2.22.4.3.7
The value of this object provides the state of the the parameter. (1-hidden 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rfalabelFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.22.4.3.8
The value of this object provides the label of the Factory Data CRC Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rfavalueFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.22.4.3.9
The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

rfastateflagFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.22.4.3.10
The value of this object provides the state of the the parameter. (1-hidden 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rfalabelAlarmDataCRC 1.3.6.1.4.1.1166.6.1.2.22.4.3.11
The value of this object provides the label of the Alarm Data CRC Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rfavalueAlarmDataCRC 1.3.6.1.4.1.1166.6.1.2.22.4.3.12
The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

rfastateflagAlarmDataCRC 1.3.6.1.4.1.1166.6.1.2.22.4.3.13
The value of this object provides the state of the the parameter. (1-hidden 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rfalabelSlopeCalDataCRC 1.3.6.1.4.1.1166.6.1.2.22.4.3.14
The value of this object provides the label of the Calibration Data CRC Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rfavalueSlopeCalDataCRC 1.3.6.1.4.1.1166.6.1.2.22.4.3.15
The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

rfastateflagSlopeCalDataCRC 1.3.6.1.4.1.1166.6.1.2.22.4.3.16
The value of this object provides the state of the the parameter. (1-hidden 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rfalabelAttnCalDataCRC 1.3.6.1.4.1.1166.6.1.2.22.4.3.17
The value of this object provides the label of the Factor Cal Setting CRC Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rfavalueAttnCalDataCRC 1.3.6.1.4.1.1166.6.1.2.22.4.3.18
The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

rfastateflagAttnCalDataCRC 1.3.6.1.4.1.1166.6.1.2.22.4.3.19
The value of this object provides the state of the the parameter. (1-hidden 2-read-only, 3-updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

rfagx2Rfa1000FactoryTableIndex 1.3.6.1.4.1.1166.6.1.2.22.5.4.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

rfabootControlByte 1.3.6.1.4.1.1166.6.1.2.22.5.4.2
The value of this object indicates which bank the firmware is currently being boot from.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rfabootStatusByte 1.3.6.1.4.1.1166.6.1.2.22.5.4.3
This object indicates the status of the last boot
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rfabank0CRC 1.3.6.1.4.1.1166.6.1.2.22.5.4.4
This object provides the CRC code of bank 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rfabank1CRC 1.3.6.1.4.1.1166.6.1.2.22.5.4.5
This object provides the CRC code of bank 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rfaprgEEPROMByte 1.3.6.1.4.1.1166.6.1.2.22.5.4.6
This object indicates if the EEPROM has been programmed
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rfafactoryCRC 1.3.6.1.4.1.1166.6.1.2.22.5.4.7
This object provides the CRC code for the Factory data.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rfacalculateCRC 1.3.6.1.4.1.1166.6.1.2.22.5.4.8
This object indicates which of the Emnums will have the CRC calculated.
Status: obsolete Access: read-only
OBJECT-TYPE    
  INTEGER factory(1), calibration(2), alarmdata(3), calSetting(4)  

rfahourMeter 1.3.6.1.4.1.1166.6.1.2.22.5.4.9
This object provides the hour meter reading of the module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rfaflashPrgCntA 1.3.6.1.4.1.1166.6.1.2.22.5.4.10
This object provides the number of times the flash has been programmed on side A.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rfaflashPrgCntB 1.3.6.1.4.1.1166.6.1.2.22.5.4.11
This object provides the number of times the flash has been programmed on side B.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rfafwRev0 1.3.6.1.4.1.1166.6.1.2.22.5.4.12
This object provides the Revision of the firmware stores in bank 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rfafwRev1 1.3.6.1.4.1.1166.6.1.2.22.5.4.13
This object provides the Revision of the firmware stores in bank 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

gx2Rfa1000HoldTimeTableIndex 1.3.6.1.4.1.1166.6.1.2.22.6.5.1
The value of this object is the index of the data object.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

gx2Rfa1000HoldTimeSpecIndex 1.3.6.1.4.1.1166.6.1.2.22.6.5.2
The value of this object identifies the index of the alarm object to be modified.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

gx2Rfa1000HoldTimeData 1.3.6.1.4.1.1166.6.1.2.22.6.5.3
The value of this object provides access to the hold timers used to suppress nose on analog objects. This object is a 32 bit object. Validation data is entered into bytes zero and one of the object. Bytes three and four are used to entering the hold time for the specified alarm object. The Hold timer data ranges from 0 to 1300 seconds. The index of this object corresponds to the alarm object to be modified. Alarm Hold timers correspond to the index of this object as follows: Index 1 = xxx, index 2 = xxxx, Index 3 = xxxx, The hold time is represented in seconds.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

trapRFA1000ConfigChangeInteger 1
This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE    

trapRFA1000ConfigChangeDisplayString 2
This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE    

trapRFA1000ModuleTemperatureAlarm 3
This trap is issued when the RFA1000 Module's Temperature goes out of range.
TRAP-TYPE    

trapRFA1000FanCurrentAlarm 4
This trap is issued when the RFA1000 Module's Fan Currrent parameter goes out of range.
TRAP-TYPE    

trapRFA1000Plus12CurrentAlarm 5
This trap is issued when the RFA1000 Module's positive 12 volt current parameter goes out of range.
TRAP-TYPE    

trapRFA1000Boot0Alarm 6
This trap is issued when the RFA1000 Module's Bank 0 Boot sequence has detected an error.
TRAP-TYPE    

trapRFA1000Boot1Alarm 7
This trap is issued when the RFA1000 Module's Bank 1 Boot sequence has detected an error.
TRAP-TYPE    

trapRFA1000FlashAlarm 8
This trap is issued when the RFA1000 Module's boot or flash programming sequence has detected a Flash error.
TRAP-TYPE    

trapRFA1000AlarmDataCRCAlarm 9
This trap is issued when the RFA1000 Module detects an error calculating the alarm limit CRC.
TRAP-TYPE    

trapRFA1000FactoryDataCRCAlarm 10
This trap is issued when the RFA1000 Module detects an error calculating the Factory data CRC.
TRAP-TYPE    

trapRFA1000SlopeCalDataCRCAlarm 11
This trap is issued when the RFA1000 Module detects an error calculating the Slope Calibration data CRC.
TRAP-TYPE    

trapRFA1000AttnCalDataCRCAlarm 12
This trap is issued when the RFA1000 Module detects an Attenuation Calibration Data CRC alarm.
TRAP-TYPE    

trapRFA1000ResetFacDefault 13
This trap is issued when the RFA1000 resets to factory defaults
TRAP-TYPE