OMNI-gx2GS1000-MIB

File: OMNI-gx2GS1000-MIB.mib (103591 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC1213-MIB
RFC-1215 NLS-BBNIDENT-MIB GX2HFC-MIB
NLSBBN-TRAPS-MIB

Imported symbols

IpAddress TimeTicks Counter
OBJECT-TYPE sysUpTime DisplayString
TRAP-TYPE gi motproxies
gx2Gs1000 trapIdentifier trapNetworkElemModelNumber
trapNetworkElemSerialNum trapPerceivedSeverity trapNetworkElemOperState
trapNetworkElemAlarmStatus trapNetworkElemAdminState trapNetworkElemAvailStatus
trapText trapNETrapLastTrapTimeStamp trapChangedObjectId
trapChangedValueInteger trapChangedValueDisplayString

Defined Types

Float  
Counter    

Gx2gs1000AnalogEntry  
SEQUENCE    
  gx2gs1000AnalogTableIndex INTEGER
  gs1000labelOffsetNomMonitor DisplayString Size(0..80)
  gs1000uomOffsetNomMonitor DisplayString Size(0..80)
  gs1000majorHighOffsetNomMonitor Float
  gs1000majorLowOffsetNomMonitor Float
  gs1000minorHighOffsetNomMonitor Float
  gs1000minorLowOffsetNomMonitor Float
  gs1000currentValueOffsetNomMonitor Float
  gs1000stateFlagOffsetNomMonitor INTEGER
  gs1000minValueOffsetNomMonitor Float
  gs1000maxValueOffsetNomMonitor Float
  gs1000alarmStateOffsetNomMonitor INTEGER
  gs1000labelOffsetNomCnt DisplayString Size(0..80)
  gs1000uomOffsetNomCnt DisplayString Size(0..80)
  gs1000majorHighOffsetNomCnt Float
  gs1000majorLowOffsetNomCnt Float
  gs1000minorHighOffsetNomCnt Float
  gs1000minorLowOffsetNomCnt Float
  gs1000currentValueOffsetNomCnt Float
  gs1000stateFlagOffsetNomCnt INTEGER
  gs1000minValueOffsetNomCnt Float
  gs1000maxValueOffsetNomCnt Float
  gs1000alarmStateOffsetNomCnt INTEGER
  gs1000labelOptPower DisplayString Size(0..80)
  gs1000uomOptPower DisplayString Size(0..80)
  gs1000majorHighOptPower Float
  gs1000majorLowOptPower Float
  gs1000minorHighOptPower Float
  gs1000minorLowOptPower Float
  gs1000currentValueOptPower Float
  gs1000stateFlagOptPower INTEGER
  gs1000minValueOptPower Float
  gs1000maxValueOptPower Float
  gs1000alarmStateOptPower INTEGER
  gs1000labelLaserTemp DisplayString Size(0..80)
  gs1000uomLaserTemp DisplayString Size(0..80)
  gs1000majorHighLaserTemp Float
  gs1000majorLowLaserTemp Float
  gs1000minorHighLaserTemp Float
  gs1000minorLowLaserTemp Float
  gs1000currentValueLaserTemp Float
  gs1000stateFlagLaserTemp INTEGER
  gs1000minValueLaserTemp Float
  gs1000maxValueLaserTemp Float
  gs1000alarmStateLaserTemp INTEGER
  gs1000labelLaserBias DisplayString Size(0..80)
  gs1000uomLaserBias DisplayString Size(0..80)
  gs1000majorHighLaserBias Float
  gs1000majorLowLaserBias Float
  gs1000minorHighLaserBias Float
  gs1000minorLowLaserBias Float
  gs1000currentValueLaserBias Float
  gs1000stateFlagLaserBias INTEGER
  gs1000minValueLaserBias Float
  gs1000maxValueLaserBias Float
  gs1000alarmStateLaserBias INTEGER
  gs1000labelTecCurrent DisplayString Size(0..80)
  gs1000uomTecCurrent DisplayString Size(0..80)
  gs1000majorHighTecCurrent Float
  gs1000majorLowTecCurrent Float
  gs1000minorHighTecCurrent Float
  gs1000minorLowTecCurrent Float
  gs1000currentValueTecCurrent Float
  gs1000stateFlagTecCurrent INTEGER
  gs1000minValueTecCurrent Float
  gs1000maxValueTecCurrent Float
  gs1000alarmStateTecCurrent INTEGER
  gs1000labelModuleTemp DisplayString Size(0..80)
  gs1000uomModuleTemp DisplayString Size(0..80)
  gs1000majorHighModuleTemp Float
  gs1000majorLowModuleTemp Float
  gs1000minorHighModuleTemp Float
  gs1000minorLowModuleTemp Float
  gs1000currentValueModuleTemp Float
  gs1000stateFlagModuleTemp INTEGER
  gs1000minValueModuleTemp Float
  gs1000maxValueModuleTemp Float
  gs1000alarmStateModuleTemp INTEGER
  gs1000labelFan1Speed DisplayString Size(0..80)
  gs1000uomFan1Speed DisplayString Size(0..80)
  gs1000majorHighFan1Speed Float
  gs1000majorLowFan1Speed Float
  gs1000minorHighFan1Speed Float
  gs1000minorLowFan1Speed Float
  gs1000currentValueFan1Speed Float
  gs1000stateFlagFan1Speed INTEGER
  gs1000minValueFan1Speed Float
  gs1000maxValueFan1Speed Float
  gs1000alarmStateFan1Speed INTEGER
  gs1000labelFan2Speed DisplayString Size(0..80)
  gs1000uomFan2Speed DisplayString Size(0..80)
  gs1000majorHighFan2Speed Float
  gs1000majorLowFan2Speed Float
  gs1000minorHighFan2Speed Float
  gs1000minorLowFan2Speed Float
  gs1000currentValueFan2Speed Float
  gs1000stateFlagFan2Speed INTEGER
  gs1000minValueFan2Speed Float
  gs1000maxValueFan2Speed Float
  gs1000alarmStateFan2Speed INTEGER
  gs1000label12Volt DisplayString Size(0..80)
  gs1000uom12Volt DisplayString Size(0..80)
  gs1000majorHigh12Volt Float
  gs1000majorLow12Volt Float
  gs1000minorHigh12Volt Float
  gs1000minorLow12Volt Float
  gs1000currentValue12Volt Float
  gs1000stateFlag12Volt INTEGER
  gs1000minValue12Volt Float
  gs1000maxValue12Volt Float
  gs1000alarmState12Volt INTEGER

Gx2gs1000DigitalEntry  
SEQUENCE    
  gx2gs1000DigitalTableIndex INTEGER
  gs1000labelRfInput DisplayString Size(0..80)
  gs1000enumRfInput DisplayString Size(0..80)
  gs1000valueRfInput INTEGER
  gs1000stateflagRfInput INTEGER
  gs1000labelOptOutput DisplayString Size(0..80)
  gs1000enumOptOutput DisplayString Size(0..80)
  gs1000valueOptOutput INTEGER
  gs1000stateflagOptOutput INTEGER
  gs1000labelLaserMode DisplayString Size(0..80)
  gs1000enumLaserMode DisplayString Size(0..80)
  gs1000valueLaserMode INTEGER
  gs1000stateflagLaserMode INTEGER
  gs1000labelAttenSetting DisplayString Size(0..80)
  gs1000enumAttenSetting DisplayString Size(0..80)
  gs1000valueAttenSetting INTEGER
  gs1000stateflagAttenSetting INTEGER
  gs1000labelLaserSecMode DisplayString Size(0..80)
  gs1000enumLaserSecMode DisplayString Size(0..80)
  gs1000valueLaserSecMode INTEGER
  gs1000stateflagLaserSecMode INTEGER
  gs1000labelVideoOffset DisplayString Size(0..80)
  gs1000enumVideoOffset DisplayString Size(0..80)
  gs1000valueVideoOffset INTEGER
  gs1000stateflagVideoOffset INTEGER
  gs1000labelFactoryDefault DisplayString Size(0..80)
  gs1000enumFactoryDefault DisplayString Size(0..80)
  gs1000valueFactoryDefault INTEGER
  gs1000stateflagFactoryDefault INTEGER

Gx2gs1000StatusEntry  
SEQUENCE    
  gx2gs1000StatusTableIndex INTEGER
  gs1000labelBoot DisplayString Size(0..80)
  gs1000valueBoot INTEGER
  gs1000stateflagBoot INTEGER
  gs1000labelFlash DisplayString Size(0..80)
  gs1000valueFlash INTEGER
  gs1000stateflagFlash INTEGER
  gs1000labelFactoryDataCRC DisplayString Size(0..80)
  gs1000valueFactoryDataCRC INTEGER
  gs1000stateflagFactoryDataCRC INTEGER
  gs1000labelLaserDataCRC DisplayString Size(0..80)
  gs1000valueLaserDataCRC INTEGER
  gs1000stateflagLaserDataCRC INTEGER
  gs1000labelAlarmDataCrc DisplayString Size(0..80)
  gs1000valueAlarmDataCrc INTEGER
  gs1000stateflagAlarmDataCrc INTEGER
  gs1000labelRFInputStatus DisplayString Size(0..80)
  gs1000valueRFInputStatus INTEGER
  gs1000stateflagRFInputStatus INTEGER

Gx2gs1000FactoryEntry  
SEQUENCE    
  gx2gs1000FactoryTableIndex INTEGER
  gs1000bootControlByteValue INTEGER
  gs1000bootStatusByteValue INTEGER
  gs1000bank1CRCValue INTEGER
  gs1000bank2CRCValue INTEGER
  gs1000prgEEPROMByteValue INTEGER
  gs1000factoryCRCValue INTEGER
  gs1000calculateCRCValue INTEGER
  gs1000hourMeterValue INTEGER
  gs1000flashPrgCntAValue INTEGER
  gs1000flashPrgCntBValue INTEGER
  gs1000flashBankARevValue DisplayString Size(0..80)
  gs1000flashBankBRevValue DisplayString Size(0..80)

Defined Values

gx2gs1000Descriptor 1.3.6.1.4.1.1166.6.1.2.36.1
OBJECT IDENTIFIER    

gx2gs1000AnalogTable 1.3.6.1.4.1.1166.6.1.2.36.2
This table contains gx2Gs1000 specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2gs1000AnalogEntry

gx2gs1000AnalogEntry 1.3.6.1.4.1.1166.6.1.2.36.2.1
This list contains the analog parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2gs1000AnalogEntry  

gx2gs1000DigitalTable 1.3.6.1.4.1.1166.6.1.2.36.3
This table contains gx2Gs1000 specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2gs1000DigitalEntry

gx2gs1000DigitalEntry 1.3.6.1.4.1.1166.6.1.2.36.3.2
This list contains digital parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2gs1000DigitalEntry  

gx2gs1000StatusTable 1.3.6.1.4.1.1166.6.1.2.36.4
This table contains gx2Gs1000 specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2gs1000StatusEntry

gx2gs1000StatusEntry 1.3.6.1.4.1.1166.6.1.2.36.4.3
This list contains Status parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2gs1000StatusEntry  

gx2gs1000FactoryTable 1.3.6.1.4.1.1166.6.1.2.36.5
This table contains gx2Gs1000 specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2gs1000FactoryEntry

gx2gs1000FactoryEntry 1.3.6.1.4.1.1166.6.1.2.36.5.4
This list contains Factory parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2gs1000FactoryEntry  

gx2gs1000AnalogTableIndex 1.3.6.1.4.1.1166.6.1.2.36.2.1.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

gs1000labelOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.36.2.1.2
The value of this object provides the label of the Offset Monitor Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

gs1000uomOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.36.2.1.3
The value of this object provides the Unit of Measure of the Offset Monitor Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

gs1000majorHighOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.36.2.1.4
The value of this object provides the Major High alarm value of the Offset Monitor Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

gs1000majorLowOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.36.2.1.5
The value of this object provides the Major Low alarm value of the Offset Monitor Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

gs1000minorHighOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.36.2.1.6
The value of this object provides the Minor High alarm value of the Offset Monitor Analog parameter. This value is a float and is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

gs1000minorLowOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.36.2.1.7
The value of this object provides the Minor Low alarm value of the Offset Monitor Analog parameter. This value is a float and is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

gs1000currentValueOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.36.2.1.8
The value of this object provides the Current value of the Offset Monitor Analog parameter. This value is a float and is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

gs1000stateFlagOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.36.2.1.9
The value of this object provides the state of the Offset Monitor Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

gs1000minValueOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.36.2.1.10
The value of this object provides the minimum value the Offset Monitor Analog parameter can achive. This value is a float and is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

gs1000maxValueOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.36.2.1.11
The value of this object provides the maximum value the Offset Monitor Analog parameter can achive. This value is a float and is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

gs1000alarmStateOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.36.2.1.12
The value of this object provides the curent alarm state of the Offset Monitor Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

gs1000labelOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.36.2.1.13
The value of this object provides the label of the Offset Control Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

gs1000uomOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.36.2.1.14
The value of this object provides the label of the Offset Control Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

gs1000majorHighOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.36.2.1.15
The value of this object provides the Major High alarm value of the Offset Control Analog parameter. This value is a float and is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000)
Status: optional Access: read-only
OBJECT-TYPE    
  Float  

gs1000majorLowOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.36.2.1.16
The value of this object provides the Major Low alarm value of the Offset Control Analog parameter. This value is a float and is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000)
Status: optional Access: read-only
OBJECT-TYPE    
  Float  

gs1000minorHighOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.36.2.1.17
The value of this object provides the Minor High alarm value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000)
Status: optional Access: read-only
OBJECT-TYPE    
  Float  

gs1000minorLowOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.36.2.1.18
The value of this object provides the Minor Low alarm value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000)
Status: optional Access: read-only
OBJECT-TYPE    
  Float  

gs1000currentValueOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.36.2.1.19
The value of this object provides the Current value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Float  

gs1000stateFlagOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.36.2.1.20
The value of this object provides the state of the Offset Control Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

gs1000minValueOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.36.2.1.21
The value of this object provides the minimum value the Offset Control Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

gs1000maxValueOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.36.2.1.22
The value of this object provides the maximum value the Offset Control Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

gs1000alarmStateOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.36.2.1.23
The value of this object provides the curent alarm state of the Offset Control Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

gs1000labelOptPower 1.3.6.1.4.1.1166.6.1.2.36.2.1.24
The value of this object provides the label of the Optical Power Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

gs1000uomOptPower 1.3.6.1.4.1.1166.6.1.2.36.2.1.25
The value of this object provides the Unit of Measure of the Optical Power Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

gs1000majorHighOptPower 1.3.6.1.4.1.1166.6.1.2.36.2.1.26
The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

gs1000majorLowOptPower 1.3.6.1.4.1.1166.6.1.2.36.2.1.27
The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

gs1000minorHighOptPower 1.3.6.1.4.1.1166.6.1.2.36.2.1.28
The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000)
Status: optional Access: read-only
OBJECT-TYPE    
  Float  

gs1000minorLowOptPower 1.3.6.1.4.1.1166.6.1.2.36.2.1.29
The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000)
Status: optional Access: read-only
OBJECT-TYPE    
  Float  

gs1000currentValueOptPower 1.3.6.1.4.1.1166.6.1.2.36.2.1.30
The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

gs1000stateFlagOptPower 1.3.6.1.4.1.1166.6.1.2.36.2.1.31
The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

gs1000minValueOptPower 1.3.6.1.4.1.1166.6.1.2.36.2.1.32
The value of this object provides the minimum value the Optical Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

gs1000maxValueOptPower 1.3.6.1.4.1.1166.6.1.2.36.2.1.33
The value of this object provides the maximum value the Optical Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

gs1000alarmStateOptPower 1.3.6.1.4.1.1166.6.1.2.36.2.1.34
The value of this object provides the curent alarm state of the Optical Power Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

gs1000labelLaserTemp 1.3.6.1.4.1.1166.6.1.2.36.2.1.35
The value of this object provides the label of the Laser Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

gs1000uomLaserTemp 1.3.6.1.4.1.1166.6.1.2.36.2.1.36
The value of this object provides the Unit of Measure of the Laser Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

gs1000majorHighLaserTemp 1.3.6.1.4.1.1166.6.1.2.36.2.1.37
The value of this object provides the Major High alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

gs1000majorLowLaserTemp 1.3.6.1.4.1.1166.6.1.2.36.2.1.38
The value of this object provides the Major Low alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

gs1000minorHighLaserTemp 1.3.6.1.4.1.1166.6.1.2.36.2.1.39
The value of this object provides the Minor High alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

gs1000minorLowLaserTemp 1.3.6.1.4.1.1166.6.1.2.36.2.1.40
The value of this object provides the Minor Low alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

gs1000currentValueLaserTemp 1.3.6.1.4.1.1166.6.1.2.36.2.1.41
The value of this object provides the Current value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

gs1000stateFlagLaserTemp 1.3.6.1.4.1.1166.6.1.2.36.2.1.42
The value of this object provides the state of the Laser Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

gs1000minValueLaserTemp 1.3.6.1.4.1.1166.6.1.2.36.2.1.43
The value of this object provides the minimum value the Laser Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

gs1000maxValueLaserTemp 1.3.6.1.4.1.1166.6.1.2.36.2.1.44
The value of this object provides the maximum value the Laser Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

gs1000alarmStateLaserTemp 1.3.6.1.4.1.1166.6.1.2.36.2.1.45
The value of this object provides the curent alarm state of the Laser Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

gs1000labelLaserBias 1.3.6.1.4.1.1166.6.1.2.36.2.1.46
The value of this object provides the label of the Laser Bias Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

gs1000uomLaserBias 1.3.6.1.4.1.1166.6.1.2.36.2.1.47
The value of this object provides the Unit of Measure of the Laser Bias Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

gs1000majorHighLaserBias 1.3.6.1.4.1.1166.6.1.2.36.2.1.48
The value of this object provides the Major High alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

gs1000majorLowLaserBias 1.3.6.1.4.1.1166.6.1.2.36.2.1.49
The value of this object provides the Major Low alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

gs1000minorHighLaserBias 1.3.6.1.4.1.1166.6.1.2.36.2.1.50
The value of this object provides the Minor High alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000)
Status: optional Access: read-only
OBJECT-TYPE    
  Float  

gs1000minorLowLaserBias 1.3.6.1.4.1.1166.6.1.2.36.2.1.51
The value of this object provides the Minor Low alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000)
Status: optional Access: read-only
OBJECT-TYPE    
  Float  

gs1000currentValueLaserBias 1.3.6.1.4.1.1166.6.1.2.36.2.1.52
The value of this object provides the Current value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

gs1000stateFlagLaserBias 1.3.6.1.4.1.1166.6.1.2.36.2.1.53
The value of this object provides the state of the Laser Bias Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

gs1000minValueLaserBias 1.3.6.1.4.1.1166.6.1.2.36.2.1.54
The value of this object provides the minimum value the Laser Bias Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

gs1000maxValueLaserBias 1.3.6.1.4.1.1166.6.1.2.36.2.1.55
The value of this object provides the maximum value the Laser Bias Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

gs1000alarmStateLaserBias 1.3.6.1.4.1.1166.6.1.2.36.2.1.56
The value of this object provides the curent alarm state of the Laser Bias Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

gs1000labelTecCurrent 1.3.6.1.4.1.1166.6.1.2.36.2.1.57
The value of this object provides the label of the TEC Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

gs1000uomTecCurrent 1.3.6.1.4.1.1166.6.1.2.36.2.1.58
The value of this object provides the Unit of Measure of the TEC Current Analog parameter..
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

gs1000majorHighTecCurrent 1.3.6.1.4.1.1166.6.1.2.36.2.1.59
The value of this object provides the Major High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

gs1000majorLowTecCurrent 1.3.6.1.4.1.1166.6.1.2.36.2.1.60
The value of this object provides the Major Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

gs1000minorHighTecCurrent 1.3.6.1.4.1.1166.6.1.2.36.2.1.61
The value of this object provides the Minor High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000)
Status: optional Access: read-only
OBJECT-TYPE    
  Float  

gs1000minorLowTecCurrent 1.3.6.1.4.1.1166.6.1.2.36.2.1.62
The value of this object provides the Minor Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000)
Status: optional Access: read-only
OBJECT-TYPE    
  Float  

gs1000currentValueTecCurrent 1.3.6.1.4.1.1166.6.1.2.36.2.1.63
The value of this object provides the Current value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

gs1000stateFlagTecCurrent 1.3.6.1.4.1.1166.6.1.2.36.2.1.64
The value of this object provides the state of the TEC Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

gs1000minValueTecCurrent 1.3.6.1.4.1.1166.6.1.2.36.2.1.65
The value of this object provides the minimum value the TEC Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

gs1000maxValueTecCurrent 1.3.6.1.4.1.1166.6.1.2.36.2.1.66
The value of this object provides the maximum value the TEC Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

gs1000alarmStateTecCurrent 1.3.6.1.4.1.1166.6.1.2.36.2.1.67
The value of this object provides the curent alarm state of the TEC Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

gs1000labelModuleTemp 1.3.6.1.4.1.1166.6.1.2.36.2.1.68
The value of this object provides the label of the Module Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

gs1000uomModuleTemp 1.3.6.1.4.1.1166.6.1.2.36.2.1.69
The value of this object provides the Unit of Measure of the Module Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

gs1000majorHighModuleTemp 1.3.6.1.4.1.1166.6.1.2.36.2.1.70
The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

gs1000majorLowModuleTemp 1.3.6.1.4.1.1166.6.1.2.36.2.1.71
The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

gs1000minorHighModuleTemp 1.3.6.1.4.1.1166.6.1.2.36.2.1.72
The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

gs1000minorLowModuleTemp 1.3.6.1.4.1.1166.6.1.2.36.2.1.73
The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

gs1000currentValueModuleTemp 1.3.6.1.4.1.1166.6.1.2.36.2.1.74
The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

gs1000stateFlagModuleTemp 1.3.6.1.4.1.1166.6.1.2.36.2.1.75
The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

gs1000minValueModuleTemp 1.3.6.1.4.1.1166.6.1.2.36.2.1.76
The value of this object provides the minimum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

gs1000maxValueModuleTemp 1.3.6.1.4.1.1166.6.1.2.36.2.1.77
The value of this object provides the maximum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

gs1000alarmStateModuleTemp 1.3.6.1.4.1.1166.6.1.2.36.2.1.78
The value of this object provides the curent alarm state of the Module Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

gs1000labelFan1Speed 1.3.6.1.4.1.1166.6.1.2.36.2.1.79
The value of this object provides the label of the Fan 1 Speed Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

gs1000uomFan1Speed 1.3.6.1.4.1.1166.6.1.2.36.2.1.80
The value of this object provides the Unit of Measure of the Fan 1 Speed Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

gs1000majorHighFan1Speed 1.3.6.1.4.1.1166.6.1.2.36.2.1.81
The value of this object provides the Major High alarm value of the Fan 1 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000)
Status: optional Access: read-only
OBJECT-TYPE    
  Float  

gs1000majorLowFan1Speed 1.3.6.1.4.1.1166.6.1.2.36.2.1.82
The value of this object provides the Major Low alarm value of the Fan 1 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

gs1000minorHighFan1Speed 1.3.6.1.4.1.1166.6.1.2.36.2.1.83
The value of this object provides the Minor High alarm value of the Fan 1 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000)
Status: optional Access: read-only
OBJECT-TYPE    
  Float  

gs1000minorLowFan1Speed 1.3.6.1.4.1.1166.6.1.2.36.2.1.84
The value of this object provides the Minor Low alarm value of the Fan 1 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

gs1000currentValueFan1Speed 1.3.6.1.4.1.1166.6.1.2.36.2.1.85
The value of this object provides the Current value of the Fan 1 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

gs1000stateFlagFan1Speed 1.3.6.1.4.1.1166.6.1.2.36.2.1.86
The value of this object provides the state of the Fan 1 Speed Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

gs1000minValueFan1Speed 1.3.6.1.4.1.1166.6.1.2.36.2.1.87
The value of this object provides the minimum value the Fan 1 Speed Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

gs1000maxValueFan1Speed 1.3.6.1.4.1.1166.6.1.2.36.2.1.88
The value of this object provides the maximum value the Fan 1 Speed Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

gs1000alarmStateFan1Speed 1.3.6.1.4.1.1166.6.1.2.36.2.1.89
The value of this object provides the curent alarm state of the Fan 1 Speed Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

gs1000labelFan2Speed 1.3.6.1.4.1.1166.6.1.2.36.2.1.90
The value of this object provides the label of the Fan 2 Speed Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

gs1000uomFan2Speed 1.3.6.1.4.1.1166.6.1.2.36.2.1.91
The value of this object provides the Unit of Measure of the Fan 2 Speed Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

gs1000majorHighFan2Speed 1.3.6.1.4.1.1166.6.1.2.36.2.1.92
The value of this object provides the Major High alarm value of the Fan 2 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000)
Status: optional Access: read-only
OBJECT-TYPE    
  Float  

gs1000majorLowFan2Speed 1.3.6.1.4.1.1166.6.1.2.36.2.1.93
The value of this object provides the Major Low alarm value of the Fan 2 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

gs1000minorHighFan2Speed 1.3.6.1.4.1.1166.6.1.2.36.2.1.94
The value of this object provides the Minor High alarm value of the Fan 2 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000)
Status: optional Access: read-only
OBJECT-TYPE    
  Float  

gs1000minorLowFan2Speed 1.3.6.1.4.1.1166.6.1.2.36.2.1.95
The value of this object provides the Minor Low alarm value of the Fan 2 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

gs1000currentValueFan2Speed 1.3.6.1.4.1.1166.6.1.2.36.2.1.96
The value of this object provides the Current value of the Fan 2 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

gs1000stateFlagFan2Speed 1.3.6.1.4.1.1166.6.1.2.36.2.1.97
The value of this object provides the state of the Fan 2 Speed Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

gs1000minValueFan2Speed 1.3.6.1.4.1.1166.6.1.2.36.2.1.98
The value of this object provides the minimum value the Fan 2 Speed Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

gs1000maxValueFan2Speed 1.3.6.1.4.1.1166.6.1.2.36.2.1.99
The value of this object provides the maximum value the Fan 2 Speed Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

gs1000alarmStateFan2Speed 1.3.6.1.4.1.1166.6.1.2.36.2.1.100
The value of this object provides the curent alarm state of the Fan 2 Speed Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

gs1000label12Volt 1.3.6.1.4.1.1166.6.1.2.36.2.1.101
The value of this object provides the label of the 12v Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

gs1000uom12Volt 1.3.6.1.4.1.1166.6.1.2.36.2.1.102
The value of this object provides the Unit of Measure of the 12v Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

gs1000majorHigh12Volt 1.3.6.1.4.1.1166.6.1.2.36.2.1.103
The value of this object provides the Major High alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

gs1000majorLow12Volt 1.3.6.1.4.1.1166.6.1.2.36.2.1.104
The value of this object provides the Major Low alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

gs1000minorHigh12Volt 1.3.6.1.4.1.1166.6.1.2.36.2.1.105
The value of this object provides the Minor High alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

gs1000minorLow12Volt 1.3.6.1.4.1.1166.6.1.2.36.2.1.106
The value of this object provides the Minor Low alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

gs1000currentValue12Volt 1.3.6.1.4.1.1166.6.1.2.36.2.1.107
The value of this object provides the Current value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

gs1000stateFlag12Volt 1.3.6.1.4.1.1166.6.1.2.36.2.1.108
The value of this object provides the state of the 12v Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

gs1000minValue12Volt 1.3.6.1.4.1.1166.6.1.2.36.2.1.109
The value of this object provides the minimum value the 12v Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

gs1000maxValue12Volt 1.3.6.1.4.1.1166.6.1.2.36.2.1.110
The value of this object provides the maximum value the 12v Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

gs1000alarmState12Volt 1.3.6.1.4.1.1166.6.1.2.36.2.1.111
The value of this object provides the curent alarm state of the 12v Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

gx2gs1000DigitalTableIndex 1.3.6.1.4.1.1166.6.1.2.36.3.2.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

gs1000labelRfInput 1.3.6.1.4.1.1166.6.1.2.36.3.2.2
The value of this object provides the label of the RF Input Control Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

gs1000enumRfInput 1.3.6.1.4.1.1166.6.1.2.36.3.2.3
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

gs1000valueRfInput 1.3.6.1.4.1.1166.6.1.2.36.3.2.4
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

gs1000stateflagRfInput 1.3.6.1.4.1.1166.6.1.2.36.3.2.5
The value of this object provides the state of the RF Input Control Digital parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

gs1000labelOptOutput 1.3.6.1.4.1.1166.6.1.2.36.3.2.6
The value of this object provides the label of the Optical Output Control Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

gs1000enumOptOutput 1.3.6.1.4.1.1166.6.1.2.36.3.2.7
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

gs1000valueOptOutput 1.3.6.1.4.1.1166.6.1.2.36.3.2.8
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

gs1000stateflagOptOutput 1.3.6.1.4.1.1166.6.1.2.36.3.2.9
The value of this object provides the gs1000state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

gs1000labelLaserMode 1.3.6.1.4.1.1166.6.1.2.36.3.2.10
The value of this object provides the label of the Laser Mode Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

gs1000enumLaserMode 1.3.6.1.4.1.1166.6.1.2.36.3.2.11
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

gs1000valueLaserMode 1.3.6.1.4.1.1166.6.1.2.36.3.2.12
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER preset(1), set(2), setEquate(3), manual(4), manualEquate(5)  

gs1000stateflagLaserMode 1.3.6.1.4.1.1166.6.1.2.36.3.2.13
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

gs1000labelAttenSetting 1.3.6.1.4.1.1166.6.1.2.36.3.2.14
The value of this object provides the label of the Attenuation Setting Ditital Parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

gs1000enumAttenSetting 1.3.6.1.4.1.1166.6.1.2.36.3.2.15
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

gs1000valueAttenSetting 1.3.6.1.4.1.1166.6.1.2.36.3.2.16
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER attn0pt0(1), attn0pt5(2), attn1pt0(3), attn1pt5(4), attn2pt0(5), attn2pt5(6), attn3pt0(7), attn3pt5(8), attn4pt0(9), attn4pt5(10), attn5pt0(11), attn5pt5(12), attn6pt0(13), attn6pt5(14), attn7pt0(15), attn7pt5(16), attn8pt0(17), attn8pt5(18), attn9pt0(19), attn9pt5(20), attn10pt0(21), attn10pt5(22), attn11pt0(23), attn11pt5(24), attn12pt0(25)  

gs1000stateflagAttenSetting 1.3.6.1.4.1.1166.6.1.2.36.3.2.17
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

gs1000labelLaserSecMode 1.3.6.1.4.1.1166.6.1.2.36.3.2.18
The value of this object provides the label of the Laser Secondary Mode Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

gs1000enumLaserSecMode 1.3.6.1.4.1.1166.6.1.2.36.3.2.19
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

gs1000valueLaserSecMode 1.3.6.1.4.1.1166.6.1.2.36.3.2.20
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER cw(1), video(2)  

gs1000stateflagLaserSecMode 1.3.6.1.4.1.1166.6.1.2.36.3.2.21
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

gs1000labelVideoOffset 1.3.6.1.4.1.1166.6.1.2.36.3.2.22
The value of this object provides the label of the Video Offset Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

gs1000enumVideoOffset 1.3.6.1.4.1.1166.6.1.2.36.3.2.23
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1..
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

gs1000valueVideoOffset 1.3.6.1.4.1.1166.6.1.2.36.3.2.24
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER minus1dB(1), minus2dB(2), minus3dB(3), minus4dB(4), minus5dB(5)  

gs1000stateflagVideoOffset 1.3.6.1.4.1.1166.6.1.2.36.3.2.25
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

gs1000labelFactoryDefault 1.3.6.1.4.1.1166.6.1.2.36.3.2.26
The value of this object provides the label of the Factory Default Reset Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

gs1000enumFactoryDefault 1.3.6.1.4.1.1166.6.1.2.36.3.2.27
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

gs1000valueFactoryDefault 1.3.6.1.4.1.1166.6.1.2.36.3.2.28
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

gs1000stateflagFactoryDefault 1.3.6.1.4.1.1166.6.1.2.36.3.2.29
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

gx2gs1000StatusTableIndex 1.3.6.1.4.1.1166.6.1.2.36.4.3.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

gs1000labelBoot 1.3.6.1.4.1.1166.6.1.2.36.4.3.2
The value of this object provides the label of the Boot Status Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

gs1000valueBoot 1.3.6.1.4.1.1166.6.1.2.36.4.3.3
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

gs1000stateflagBoot 1.3.6.1.4.1.1166.6.1.2.36.4.3.4
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

gs1000labelFlash 1.3.6.1.4.1.1166.6.1.2.36.4.3.5
The value of this object provides the label of the Flash Status Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

gs1000valueFlash 1.3.6.1.4.1.1166.6.1.2.36.4.3.6
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

gs1000stateflagFlash 1.3.6.1.4.1.1166.6.1.2.36.4.3.7
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

gs1000labelFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.36.4.3.8
The value of this object provides the label of the Factory Data CRC Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

gs1000valueFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.36.4.3.9
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

gs1000stateflagFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.36.4.3.10
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

gs1000labelLaserDataCRC 1.3.6.1.4.1.1166.6.1.2.36.4.3.11
The value of this object provides the label of the Laser Data CRC Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

gs1000valueLaserDataCRC 1.3.6.1.4.1.1166.6.1.2.36.4.3.12
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

gs1000stateflagLaserDataCRC 1.3.6.1.4.1.1166.6.1.2.36.4.3.13
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

gs1000labelAlarmDataCrc 1.3.6.1.4.1.1166.6.1.2.36.4.3.14
The value of this object provides the label of the Alarm Data Crc parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

gs1000valueAlarmDataCrc 1.3.6.1.4.1.1166.6.1.2.36.4.3.15
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

gs1000stateflagAlarmDataCrc 1.3.6.1.4.1.1166.6.1.2.36.4.3.16
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

gs1000labelRFInputStatus 1.3.6.1.4.1.1166.6.1.2.36.4.3.17
The value of this object provides the label of the RF Input Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

gs1000valueRFInputStatus 1.3.6.1.4.1.1166.6.1.2.36.4.3.18
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

gs1000stateflagRFInputStatus 1.3.6.1.4.1.1166.6.1.2.36.4.3.19
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

gx2gs1000FactoryTableIndex 1.3.6.1.4.1.1166.6.1.2.36.5.4.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

gs1000bootControlByteValue 1.3.6.1.4.1.1166.6.1.2.36.5.4.2
The value of this object indicates which bank the firmware is currently being boot from.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

gs1000bootStatusByteValue 1.3.6.1.4.1.1166.6.1.2.36.5.4.3
This object indicates the status of the last boot
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

gs1000bank1CRCValue 1.3.6.1.4.1.1166.6.1.2.36.5.4.4
This object provides the CRC code of bank 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

gs1000bank2CRCValue 1.3.6.1.4.1.1166.6.1.2.36.5.4.5
This object provides the CRC code of bank 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

gs1000prgEEPROMByteValue 1.3.6.1.4.1.1166.6.1.2.36.5.4.6
This object indicates if the EEPROM has been programmed
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

gs1000factoryCRCValue 1.3.6.1.4.1.1166.6.1.2.36.5.4.7
This object provides the CRC code for the Factory data.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

gs1000calculateCRCValue 1.3.6.1.4.1.1166.6.1.2.36.5.4.8
This object indicates which of the Emnums will have the CRC calculated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER factory(1), laserData(2), alarm(3)  

gs1000hourMeterValue 1.3.6.1.4.1.1166.6.1.2.36.5.4.9
This object provides the hour meter reading of the module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

gs1000flashPrgCntAValue 1.3.6.1.4.1.1166.6.1.2.36.5.4.10
This object provides the number of times Bank 1 flash has been programmed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

gs1000flashPrgCntBValue 1.3.6.1.4.1.1166.6.1.2.36.5.4.11
This object provides the number of times Bank 1 flash has been programmed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

gs1000flashBankARevValue 1.3.6.1.4.1.1166.6.1.2.36.5.4.12
This object provides the revision of flash bank 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

gs1000flashBankBRevValue 1.3.6.1.4.1.1166.6.1.2.36.5.4.13
This object provides the revision of flash bank 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

trapGS1000ConfigChangeInteger 1
This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE    

trapGS1000ConfigChangeDisplayString 2
This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE    

trapGS1000RFInputAlarm 3
This trap is issued when the Laser Modules RF input parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapGS1000RFOverloadAlarm 4
This trap is issued when the Laser Modules RF overload parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapGS1000RFOffsetAlarm 5
This trap is issued when the Laser Modules RF Offset parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapGS1000OpticalPowerAlarm 6
This trap is issued when the Laser Modules Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapGS1000LaserBiasAlarm 7
This trap is issued when the Laser Bias parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapGS1000LaserTempAlarm 8
This trap is issued when the Laser Temperature parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapGS1000TECCurrentAlarm 9
This trap is issued when the Laser Modules TEC Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapGS1000Fan1SpeedAlarm 10
This trap is issued when the Laser Modules Fan 1 Speed parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapGS1000Fan2SpeedAlarm 11
This trap is issued when the Laser Modules Fan 2 Speed parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapGS100012vAlarm 12
This trap is issued when the Laser Modules 12 Volt parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapGS1000ModuleTempAlarm 13
This trap is issued when the Laser Module Temperature goes out of range.
TRAP-TYPE    

trapGS1000FlashAlarm 14
This trap is issued when the Laser Modules detects an error during Flash memory operations.
TRAP-TYPE    

trapGS1000LaserBiasCntLoopAlarm 15
This trap is issued when the Laser Modules detects an error in its Laser Bias control loop operation.
TRAP-TYPE    

trapGS1000BankBootAlarm 16
This trap is issued when the Laser Modules detects an error while booting from bank 0 or bank 1.
TRAP-TYPE    

trapGS1000LaserBiasCntLoopInitAlarm 17
This trap is issued when the Laser Bias Control loop init fails.
TRAP-TYPE    

trapGS1000RFParamInitAlarm 18
This trap is issued when the RF parameter Init fails.
TRAP-TYPE    

trapGS1000TECParamInitAlarm 19
This trap is issued when the TEC Parameter Init fails.
TRAP-TYPE    

trapGS1000AttnTableInitAlarm 20
This trap is issued when the Attenuator Table Init fails.
TRAP-TYPE    

trapGS1000PowerMeterTableInitAlarm 21
This trap is issued when the Power Meter Table Init fails.
TRAP-TYPE    

trapGS1000LaserDataCRCAlarm 22
This trap is issued when the Laser Data CRC is incorrect.
TRAP-TYPE    

trapGS1000AlarmDataCRCAlarm 23
This trap is issued when the Alarm Data CRC is incorrect.
TRAP-TYPE    

trapGS1000FactoryDataCRCAlarm 24
This trap is issued when the Factory Data CRC is incorrect.
TRAP-TYPE    

trapGS1000UserRFOffAlarm 25
This trap is issued when the the User RF is turned off.
TRAP-TYPE    

trapGS1000UserOpticalOffAlarm 26
This trap is issued when the User Optical Power is turned off.
TRAP-TYPE    

trapGS1000ResetFactoryDefaultAlarm 27
This trap is issued when the Factory Default Reset occurs.
TRAP-TYPE