OMNI-gx2EA1000-MIB

File: OMNI-gx2EA1000-MIB.mib (103589 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC1213-MIB
RFC-1215 NLS-BBNIDENT-MIB GX2HFC-MIB
NLSBBN-TRAPS-MIB

Imported symbols

IpAddress TimeTicks Counter
OBJECT-TYPE sysUpTime DisplayString
TRAP-TYPE gi motproxies
gx2Ea1000 trapIdentifier trapNetworkElemModelNumber
trapNetworkElemSerialNum trapPerceivedSeverity trapNetworkElemOperState
trapNetworkElemAlarmStatus trapNetworkElemAdminState trapNetworkElemAvailStatus
trapText trapNETrapLastTrapTimeStamp trapChangedObjectId
trapChangedValueInteger trapChangedValueDisplayString

Defined Types

Float  
Counter    

Gx2ea1000AnalogEntry  
SEQUENCE    
  gx2ea1000AnalogTableIndex INTEGER
  ea1000labelOffsetNomMonitor DisplayString Size(0..80)
  ea1000uomOffsetNomMonitor DisplayString Size(0..80)
  ea1000majorHighOffsetNomMonitor Float
  ea1000majorLowOffsetNomMonitor Float
  ea1000minorHighOffsetNomMonitor Float
  ea1000minorLowOffsetNomMonitor Float
  ea1000currentValueOffsetNomMonitor Float
  ea1000stateFlagOffsetNomMonitor INTEGER
  ea1000minValueOffsetNomMonitor Float
  ea1000maxValueOffsetNomMonitor Float
  ea1000alarmStateOffsetNomMonitor INTEGER
  ea1000labelOffsetNomCnt DisplayString Size(0..80)
  ea1000uomOffsetNomCnt DisplayString Size(0..80)
  ea1000majorHighOffsetNomCnt Float
  ea1000majorLowOffsetNomCnt Float
  ea1000minorHighOffsetNomCnt Float
  ea1000minorLowOffsetNomCnt Float
  ea1000currentValueOffsetNomCnt Float
  ea1000stateFlagOffsetNomCnt INTEGER
  ea1000minValueOffsetNomCnt Float
  ea1000maxValueOffsetNomCnt Float
  ea1000alarmStateOffsetNomCnt INTEGER
  ea1000labelOptPower DisplayString Size(0..80)
  ea1000uomOptPower DisplayString Size(0..80)
  ea1000majorHighOptPower Float
  ea1000majorLowOptPower Float
  ea1000minorHighOptPower Float
  ea1000minorLowOptPower Float
  ea1000currentValueOptPower Float
  ea1000stateFlagOptPower INTEGER
  ea1000minValueOptPower Float
  ea1000maxValueOptPower Float
  ea1000alarmStateOptPower INTEGER
  ea1000labelLaserTemp DisplayString Size(0..80)
  ea1000uomLaserTemp DisplayString Size(0..80)
  ea1000majorHighLaserTemp Float
  ea1000majorLowLaserTemp Float
  ea1000minorHighLaserTemp Float
  ea1000minorLowLaserTemp Float
  ea1000currentValueLaserTemp Float
  ea1000stateFlagLaserTemp INTEGER
  ea1000minValueLaserTemp Float
  ea1000maxValueLaserTemp Float
  ea1000alarmStateLaserTemp INTEGER
  ea1000labelLaserBias DisplayString Size(0..80)
  ea1000uomLaserBias DisplayString Size(0..80)
  ea1000majorHighLaserBias Float
  ea1000majorLowLaserBias Float
  ea1000minorHighLaserBias Float
  ea1000minorLowLaserBias Float
  ea1000currentValueLaserBias Float
  ea1000stateFlagLaserBias INTEGER
  ea1000minValueLaserBias Float
  ea1000maxValueLaserBias Float
  ea1000alarmStateLaserBias INTEGER
  ea1000labelTecCurrent DisplayString Size(0..80)
  ea1000uomTecCurrent DisplayString Size(0..80)
  ea1000majorHighTecCurrent Float
  ea1000majorLowTecCurrent Float
  ea1000minorHighTecCurrent Float
  ea1000minorLowTecCurrent Float
  ea1000currentValueTecCurrent Float
  ea1000stateFlagTecCurrent INTEGER
  ea1000minValueTecCurrent Float
  ea1000maxValueTecCurrent Float
  ea1000alarmStateTecCurrent INTEGER
  ea1000labelModuleTemp DisplayString Size(0..80)
  ea1000uomModuleTemp DisplayString Size(0..80)
  ea1000majorHighModuleTemp Float
  ea1000majorLowModuleTemp Float
  ea1000minorHighModuleTemp Float
  ea1000minorLowModuleTemp Float
  ea1000currentValueModuleTemp Float
  ea1000stateFlagModuleTemp INTEGER
  ea1000minValueModuleTemp Float
  ea1000maxValueModuleTemp Float
  ea1000alarmStateModuleTemp INTEGER
  ea1000labelFan1Speed DisplayString Size(0..80)
  ea1000uomFan1Speed DisplayString Size(0..80)
  ea1000majorHighFan1Speed Float
  ea1000majorLowFan1Speed Float
  ea1000minorHighFan1Speed Float
  ea1000minorLowFan1Speed Float
  ea1000currentValueFan1Speed Float
  ea1000stateFlagFan1Speed INTEGER
  ea1000minValueFan1Speed Float
  ea1000maxValueFan1Speed Float
  ea1000alarmStateFan1Speed INTEGER
  ea1000labelFan2Speed DisplayString Size(0..80)
  ea1000uomFan2Speed DisplayString Size(0..80)
  ea1000majorHighFan2Speed Float
  ea1000majorLowFan2Speed Float
  ea1000minorHighFan2Speed Float
  ea1000minorLowFan2Speed Float
  ea1000currentValueFan2Speed Float
  ea1000stateFlagFan2Speed INTEGER
  ea1000minValueFan2Speed Float
  ea1000maxValueFan2Speed Float
  ea1000alarmStateFan2Speed INTEGER
  ea1000label12Volt DisplayString Size(0..80)
  ea1000uom12Volt DisplayString Size(0..80)
  ea1000majorHigh12Volt Float
  ea1000majorLow12Volt Float
  ea1000minorHigh12Volt Float
  ea1000minorLow12Volt Float
  ea1000currentValue12Volt Float
  ea1000stateFlag12Volt INTEGER
  ea1000minValue12Volt Float
  ea1000maxValue12Volt Float
  ea1000alarmState12Volt INTEGER

Gx2ea1000DigitalEntry  
SEQUENCE    
  gx2ea1000DigitalTableIndex INTEGER
  ea1000labelRfInput DisplayString Size(0..80)
  ea1000enumRfInput DisplayString Size(0..80)
  ea1000valueRfInput INTEGER
  ea1000stateflagRfInput INTEGER
  ea1000labelOptOutput DisplayString Size(0..80)
  ea1000enumOptOutput DisplayString Size(0..80)
  ea1000valueOptOutput INTEGER
  ea1000stateflagOptOutput INTEGER
  ea1000labelLaserMode DisplayString Size(0..80)
  ea1000enumLaserMode DisplayString Size(0..80)
  ea1000valueLaserMode INTEGER
  ea1000stateflagLaserMode INTEGER
  ea1000labelAttenSetting DisplayString Size(0..80)
  ea1000enumAttenSetting DisplayString Size(0..80)
  ea1000valueAttenSetting INTEGER
  ea1000stateflagAttenSetting INTEGER
  ea1000labelLaserSecMode DisplayString Size(0..80)
  ea1000enumLaserSecMode DisplayString Size(0..80)
  ea1000valueLaserSecMode INTEGER
  ea1000stateflagLaserSecMode INTEGER
  ea1000labelVideoOffset DisplayString Size(0..80)
  ea1000enumVideoOffset DisplayString Size(0..80)
  ea1000valueVideoOffset INTEGER
  ea1000stateflagVideoOffset INTEGER
  ea1000labelFactoryDefault DisplayString Size(0..80)
  ea1000enumFactoryDefault DisplayString Size(0..80)
  ea1000valueFactoryDefault INTEGER
  ea1000stateflagFactoryDefault INTEGER

Gx2ea1000StatusEntry  
SEQUENCE    
  gx2ea1000StatusTableIndex INTEGER
  ea1000labelBoot DisplayString Size(0..80)
  ea1000valueBoot INTEGER
  ea1000stateflagBoot INTEGER
  ea1000labelFlash DisplayString Size(0..80)
  ea1000valueFlash INTEGER
  ea1000stateflagFlash INTEGER
  ea1000labelFactoryDataCRC DisplayString Size(0..80)
  ea1000valueFactoryDataCRC INTEGER
  ea1000stateflagFactoryDataCRC INTEGER
  ea1000labelLaserDataCRC DisplayString Size(0..80)
  ea1000valueLaserDataCRC INTEGER
  ea1000stateflagLaserDataCRC INTEGER
  ea1000labelAlarmDataCrc DisplayString Size(0..80)
  ea1000valueAlarmDataCrc INTEGER
  ea1000stateflagAlarmDataCrc INTEGER
  ea1000labelRFInputStatus DisplayString Size(0..80)
  ea1000valueRFInputStatus INTEGER
  ea1000stateflagRFInputStatus INTEGER

Gx2ea1000FactoryEntry  
SEQUENCE    
  gx2ea1000FactoryTableIndex INTEGER
  ea1000bootControlByteValue INTEGER
  ea1000bootStatusByteValue INTEGER
  ea1000bank1CRCValue INTEGER
  ea1000bank2CRCValue INTEGER
  ea1000prgEEPROMByteValue INTEGER
  ea1000factoryCRCValue INTEGER
  ea1000calculateCRCValue INTEGER
  ea1000hourMeterValue INTEGER
  ea1000flashPrgCntAValue INTEGER
  ea1000flashPrgCntBValue INTEGER
  ea1000flashBankARevValue DisplayString Size(0..80)
  ea1000flashBankBRevValue DisplayString Size(0..80)

Defined Values

gx2ea1000Descriptor 1.3.6.1.4.1.1166.6.1.2.33.1
OBJECT IDENTIFIER    

gx2ea1000AnalogTable 1.3.6.1.4.1.1166.6.1.2.33.2
This table contains gx2Ea1000 specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2ea1000AnalogEntry

gx2ea1000AnalogEntry 1.3.6.1.4.1.1166.6.1.2.33.2.1
This list contains the analog parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2ea1000AnalogEntry  

gx2ea1000DigitalTable 1.3.6.1.4.1.1166.6.1.2.33.3
This table contains gx2Ea1000 specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2ea1000DigitalEntry

gx2ea1000DigitalEntry 1.3.6.1.4.1.1166.6.1.2.33.3.2
This list contains digital parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2ea1000DigitalEntry  

gx2ea1000StatusTable 1.3.6.1.4.1.1166.6.1.2.33.4
This table contains gx2Ea1000 specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2ea1000StatusEntry

gx2ea1000StatusEntry 1.3.6.1.4.1.1166.6.1.2.33.4.3
This list contains Status parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2ea1000StatusEntry  

gx2ea1000FactoryTable 1.3.6.1.4.1.1166.6.1.2.33.5
This table contains gx2Ea1000 specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2ea1000FactoryEntry

gx2ea1000FactoryEntry 1.3.6.1.4.1.1166.6.1.2.33.5.4
This list contains Factory parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2ea1000FactoryEntry  

gx2ea1000AnalogTableIndex 1.3.6.1.4.1.1166.6.1.2.33.2.1.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

ea1000labelOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.33.2.1.2
The value of this object provides the label of the Offset Monitor Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

ea1000uomOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.33.2.1.3
The value of this object provides the Unit of Measure of the Offset Monitor Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

ea1000majorHighOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.33.2.1.4
The value of this object provides the Major High alarm value of the Offset Monitor Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

ea1000majorLowOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.33.2.1.5
The value of this object provides the Major Low alarm value of the Offset Monitor Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

ea1000minorHighOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.33.2.1.6
The value of this object provides the Minor High alarm value of the Offset Monitor Analog parameter. This value is a float and is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

ea1000minorLowOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.33.2.1.7
The value of this object provides the Minor Low alarm value of the Offset Monitor Analog parameter. This value is a float and is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

ea1000currentValueOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.33.2.1.8
The value of this object provides the Current value of the Offset Monitor Analog parameter. This value is a float and is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

ea1000stateFlagOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.33.2.1.9
The value of this object provides the state of the Offset Monitor Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

ea1000minValueOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.33.2.1.10
The value of this object provides the minimum value the Offset Monitor Analog parameter can achive. This value is a float and is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

ea1000maxValueOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.33.2.1.11
The value of this object provides the maximum value the Offset Monitor Analog parameter can achive. This value is a float and is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

ea1000alarmStateOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.33.2.1.12
The value of this object provides the curent alarm state of the Offset Monitor Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

ea1000labelOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.33.2.1.13
The value of this object provides the label of the Offset Control Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

ea1000uomOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.33.2.1.14
The value of this object provides the label of the Offset Control Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

ea1000majorHighOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.33.2.1.15
The value of this object provides the Major High alarm value of the Offset Control Analog parameter. This value is a float and is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000)
Status: optional Access: read-only
OBJECT-TYPE    
  Float  

ea1000majorLowOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.33.2.1.16
The value of this object provides the Major Low alarm value of the Offset Control Analog parameter. This value is a float and is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000)
Status: optional Access: read-only
OBJECT-TYPE    
  Float  

ea1000minorHighOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.33.2.1.17
The value of this object provides the Minor High alarm value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000)
Status: optional Access: read-only
OBJECT-TYPE    
  Float  

ea1000minorLowOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.33.2.1.18
The value of this object provides the Minor Low alarm value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000)
Status: optional Access: read-only
OBJECT-TYPE    
  Float  

ea1000currentValueOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.33.2.1.19
The value of this object provides the Current value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Float  

ea1000stateFlagOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.33.2.1.20
The value of this object provides the state of the Offset Control Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

ea1000minValueOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.33.2.1.21
The value of this object provides the minimum value the Offset Control Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

ea1000maxValueOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.33.2.1.22
The value of this object provides the maximum value the Offset Control Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

ea1000alarmStateOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.33.2.1.23
The value of this object provides the curent alarm state of the Offset Control Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

ea1000labelOptPower 1.3.6.1.4.1.1166.6.1.2.33.2.1.24
The value of this object provides the label of the Optical Power Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

ea1000uomOptPower 1.3.6.1.4.1.1166.6.1.2.33.2.1.25
The value of this object provides the Unit of Measure of the Optical Power Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

ea1000majorHighOptPower 1.3.6.1.4.1.1166.6.1.2.33.2.1.26
The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

ea1000majorLowOptPower 1.3.6.1.4.1.1166.6.1.2.33.2.1.27
The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

ea1000minorHighOptPower 1.3.6.1.4.1.1166.6.1.2.33.2.1.28
The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000)
Status: optional Access: read-only
OBJECT-TYPE    
  Float  

ea1000minorLowOptPower 1.3.6.1.4.1.1166.6.1.2.33.2.1.29
The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000)
Status: optional Access: read-only
OBJECT-TYPE    
  Float  

ea1000currentValueOptPower 1.3.6.1.4.1.1166.6.1.2.33.2.1.30
The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

ea1000stateFlagOptPower 1.3.6.1.4.1.1166.6.1.2.33.2.1.31
The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

ea1000minValueOptPower 1.3.6.1.4.1.1166.6.1.2.33.2.1.32
The value of this object provides the minimum value the Optical Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

ea1000maxValueOptPower 1.3.6.1.4.1.1166.6.1.2.33.2.1.33
The value of this object provides the maximum value the Optical Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

ea1000alarmStateOptPower 1.3.6.1.4.1.1166.6.1.2.33.2.1.34
The value of this object provides the curent alarm state of the Optical Power Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

ea1000labelLaserTemp 1.3.6.1.4.1.1166.6.1.2.33.2.1.35
The value of this object provides the label of the Laser Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

ea1000uomLaserTemp 1.3.6.1.4.1.1166.6.1.2.33.2.1.36
The value of this object provides the Unit of Measure of the Laser Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

ea1000majorHighLaserTemp 1.3.6.1.4.1.1166.6.1.2.33.2.1.37
The value of this object provides the Major High alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

ea1000majorLowLaserTemp 1.3.6.1.4.1.1166.6.1.2.33.2.1.38
The value of this object provides the Major Low alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

ea1000minorHighLaserTemp 1.3.6.1.4.1.1166.6.1.2.33.2.1.39
The value of this object provides the Minor High alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

ea1000minorLowLaserTemp 1.3.6.1.4.1.1166.6.1.2.33.2.1.40
The value of this object provides the Minor Low alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

ea1000currentValueLaserTemp 1.3.6.1.4.1.1166.6.1.2.33.2.1.41
The value of this object provides the Current value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

ea1000stateFlagLaserTemp 1.3.6.1.4.1.1166.6.1.2.33.2.1.42
The value of this object provides the state of the Laser Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

ea1000minValueLaserTemp 1.3.6.1.4.1.1166.6.1.2.33.2.1.43
The value of this object provides the minimum value the Laser Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

ea1000maxValueLaserTemp 1.3.6.1.4.1.1166.6.1.2.33.2.1.44
The value of this object provides the maximum value the Laser Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

ea1000alarmStateLaserTemp 1.3.6.1.4.1.1166.6.1.2.33.2.1.45
The value of this object provides the curent alarm state of the Laser Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

ea1000labelLaserBias 1.3.6.1.4.1.1166.6.1.2.33.2.1.46
The value of this object provides the label of the Laser Bias Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

ea1000uomLaserBias 1.3.6.1.4.1.1166.6.1.2.33.2.1.47
The value of this object provides the Unit of Measure of the Laser Bias Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

ea1000majorHighLaserBias 1.3.6.1.4.1.1166.6.1.2.33.2.1.48
The value of this object provides the Major High alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

ea1000majorLowLaserBias 1.3.6.1.4.1.1166.6.1.2.33.2.1.49
The value of this object provides the Major Low alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

ea1000minorHighLaserBias 1.3.6.1.4.1.1166.6.1.2.33.2.1.50
The value of this object provides the Minor High alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000)
Status: optional Access: read-only
OBJECT-TYPE    
  Float  

ea1000minorLowLaserBias 1.3.6.1.4.1.1166.6.1.2.33.2.1.51
The value of this object provides the Minor Low alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000)
Status: optional Access: read-only
OBJECT-TYPE    
  Float  

ea1000currentValueLaserBias 1.3.6.1.4.1.1166.6.1.2.33.2.1.52
The value of this object provides the Current value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

ea1000stateFlagLaserBias 1.3.6.1.4.1.1166.6.1.2.33.2.1.53
The value of this object provides the state of the Laser Bias Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

ea1000minValueLaserBias 1.3.6.1.4.1.1166.6.1.2.33.2.1.54
The value of this object provides the minimum value the Laser Bias Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

ea1000maxValueLaserBias 1.3.6.1.4.1.1166.6.1.2.33.2.1.55
The value of this object provides the maximum value the Laser Bias Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

ea1000alarmStateLaserBias 1.3.6.1.4.1.1166.6.1.2.33.2.1.56
The value of this object provides the curent alarm state of the Laser Bias Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

ea1000labelTecCurrent 1.3.6.1.4.1.1166.6.1.2.33.2.1.57
The value of this object provides the label of the TEC Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

ea1000uomTecCurrent 1.3.6.1.4.1.1166.6.1.2.33.2.1.58
The value of this object provides the Unit of Measure of the TEC Current Analog parameter..
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

ea1000majorHighTecCurrent 1.3.6.1.4.1.1166.6.1.2.33.2.1.59
The value of this object provides the Major High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

ea1000majorLowTecCurrent 1.3.6.1.4.1.1166.6.1.2.33.2.1.60
The value of this object provides the Major Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

ea1000minorHighTecCurrent 1.3.6.1.4.1.1166.6.1.2.33.2.1.61
The value of this object provides the Minor High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000)
Status: optional Access: read-only
OBJECT-TYPE    
  Float  

ea1000minorLowTecCurrent 1.3.6.1.4.1.1166.6.1.2.33.2.1.62
The value of this object provides the Minor Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000)
Status: optional Access: read-only
OBJECT-TYPE    
  Float  

ea1000currentValueTecCurrent 1.3.6.1.4.1.1166.6.1.2.33.2.1.63
The value of this object provides the Current value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

ea1000stateFlagTecCurrent 1.3.6.1.4.1.1166.6.1.2.33.2.1.64
The value of this object provides the state of the TEC Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

ea1000minValueTecCurrent 1.3.6.1.4.1.1166.6.1.2.33.2.1.65
The value of this object provides the minimum value the TEC Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

ea1000maxValueTecCurrent 1.3.6.1.4.1.1166.6.1.2.33.2.1.66
The value of this object provides the maximum value the TEC Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

ea1000alarmStateTecCurrent 1.3.6.1.4.1.1166.6.1.2.33.2.1.67
The value of this object provides the curent alarm state of the TEC Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

ea1000labelModuleTemp 1.3.6.1.4.1.1166.6.1.2.33.2.1.68
The value of this object provides the label of the Module Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

ea1000uomModuleTemp 1.3.6.1.4.1.1166.6.1.2.33.2.1.69
The value of this object provides the Unit of Measure of the Module Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

ea1000majorHighModuleTemp 1.3.6.1.4.1.1166.6.1.2.33.2.1.70
The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

ea1000majorLowModuleTemp 1.3.6.1.4.1.1166.6.1.2.33.2.1.71
The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

ea1000minorHighModuleTemp 1.3.6.1.4.1.1166.6.1.2.33.2.1.72
The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

ea1000minorLowModuleTemp 1.3.6.1.4.1.1166.6.1.2.33.2.1.73
The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

ea1000currentValueModuleTemp 1.3.6.1.4.1.1166.6.1.2.33.2.1.74
The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

ea1000stateFlagModuleTemp 1.3.6.1.4.1.1166.6.1.2.33.2.1.75
The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

ea1000minValueModuleTemp 1.3.6.1.4.1.1166.6.1.2.33.2.1.76
The value of this object provides the minimum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

ea1000maxValueModuleTemp 1.3.6.1.4.1.1166.6.1.2.33.2.1.77
The value of this object provides the maximum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

ea1000alarmStateModuleTemp 1.3.6.1.4.1.1166.6.1.2.33.2.1.78
The value of this object provides the curent alarm state of the Module Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

ea1000labelFan1Speed 1.3.6.1.4.1.1166.6.1.2.33.2.1.79
The value of this object provides the label of the Fan 1 Speed Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

ea1000uomFan1Speed 1.3.6.1.4.1.1166.6.1.2.33.2.1.80
The value of this object provides the Unit of Measure of the Fan 1 Speed Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

ea1000majorHighFan1Speed 1.3.6.1.4.1.1166.6.1.2.33.2.1.81
The value of this object provides the Major High alarm value of the Fan 1 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000)
Status: optional Access: read-only
OBJECT-TYPE    
  Float  

ea1000majorLowFan1Speed 1.3.6.1.4.1.1166.6.1.2.33.2.1.82
The value of this object provides the Major Low alarm value of the Fan 1 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

ea1000minorHighFan1Speed 1.3.6.1.4.1.1166.6.1.2.33.2.1.83
The value of this object provides the Minor High alarm value of the Fan 1 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000)
Status: optional Access: read-only
OBJECT-TYPE    
  Float  

ea1000minorLowFan1Speed 1.3.6.1.4.1.1166.6.1.2.33.2.1.84
The value of this object provides the Minor Low alarm value of the Fan 1 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

ea1000currentValueFan1Speed 1.3.6.1.4.1.1166.6.1.2.33.2.1.85
The value of this object provides the Current value of the Fan 1 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

ea1000stateFlagFan1Speed 1.3.6.1.4.1.1166.6.1.2.33.2.1.86
The value of this object provides the state of the Fan 1 Speed Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

ea1000minValueFan1Speed 1.3.6.1.4.1.1166.6.1.2.33.2.1.87
The value of this object provides the minimum value the Fan 1 Speed Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

ea1000maxValueFan1Speed 1.3.6.1.4.1.1166.6.1.2.33.2.1.88
The value of this object provides the maximum value the Fan 1 Speed Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

ea1000alarmStateFan1Speed 1.3.6.1.4.1.1166.6.1.2.33.2.1.89
The value of this object provides the curent alarm state of the Fan 1 Speed Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

ea1000labelFan2Speed 1.3.6.1.4.1.1166.6.1.2.33.2.1.90
The value of this object provides the label of the Fan 2 Speed Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

ea1000uomFan2Speed 1.3.6.1.4.1.1166.6.1.2.33.2.1.91
The value of this object provides the Unit of Measure of the Fan 2 Speed Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

ea1000majorHighFan2Speed 1.3.6.1.4.1.1166.6.1.2.33.2.1.92
The value of this object provides the Major High alarm value of the Fan 2 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000)
Status: optional Access: read-only
OBJECT-TYPE    
  Float  

ea1000majorLowFan2Speed 1.3.6.1.4.1.1166.6.1.2.33.2.1.93
The value of this object provides the Major Low alarm value of the Fan 2 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

ea1000minorHighFan2Speed 1.3.6.1.4.1.1166.6.1.2.33.2.1.94
The value of this object provides the Minor High alarm value of the Fan 2 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. In this version of the Firmware and MIB this Parameter is not used and is optional. All reads will return the Unused Parameter (10,000,000)
Status: optional Access: read-only
OBJECT-TYPE    
  Float  

ea1000minorLowFan2Speed 1.3.6.1.4.1.1166.6.1.2.33.2.1.95
The value of this object provides the Minor Low alarm value of the Fan 2 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

ea1000currentValueFan2Speed 1.3.6.1.4.1.1166.6.1.2.33.2.1.96
The value of this object provides the Current value of the Fan 2 Speed Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

ea1000stateFlagFan2Speed 1.3.6.1.4.1.1166.6.1.2.33.2.1.97
The value of this object provides the state of the Fan 2 Speed Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

ea1000minValueFan2Speed 1.3.6.1.4.1.1166.6.1.2.33.2.1.98
The value of this object provides the minimum value the Fan 2 Speed Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

ea1000maxValueFan2Speed 1.3.6.1.4.1.1166.6.1.2.33.2.1.99
The value of this object provides the maximum value the Fan 2 Speed Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

ea1000alarmStateFan2Speed 1.3.6.1.4.1.1166.6.1.2.33.2.1.100
The value of this object provides the curent alarm state of the Fan 2 Speed Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

ea1000label12Volt 1.3.6.1.4.1.1166.6.1.2.33.2.1.101
The value of this object provides the label of the 12v Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

ea1000uom12Volt 1.3.6.1.4.1.1166.6.1.2.33.2.1.102
The value of this object provides the Unit of Measure of the 12v Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

ea1000majorHigh12Volt 1.3.6.1.4.1.1166.6.1.2.33.2.1.103
The value of this object provides the Major High alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

ea1000majorLow12Volt 1.3.6.1.4.1.1166.6.1.2.33.2.1.104
The value of this object provides the Major Low alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

ea1000minorHigh12Volt 1.3.6.1.4.1.1166.6.1.2.33.2.1.105
The value of this object provides the Minor High alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

ea1000minorLow12Volt 1.3.6.1.4.1.1166.6.1.2.33.2.1.106
The value of this object provides the Minor Low alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

ea1000currentValue12Volt 1.3.6.1.4.1.1166.6.1.2.33.2.1.107
The value of this object provides the Current value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

ea1000stateFlag12Volt 1.3.6.1.4.1.1166.6.1.2.33.2.1.108
The value of this object provides the state of the 12v Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

ea1000minValue12Volt 1.3.6.1.4.1.1166.6.1.2.33.2.1.109
The value of this object provides the minimum value the 12v Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

ea1000maxValue12Volt 1.3.6.1.4.1.1166.6.1.2.33.2.1.110
The value of this object provides the maximum value the 12v Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

ea1000alarmState12Volt 1.3.6.1.4.1.1166.6.1.2.33.2.1.111
The value of this object provides the curent alarm state of the 12v Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

gx2ea1000DigitalTableIndex 1.3.6.1.4.1.1166.6.1.2.33.3.2.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

ea1000labelRfInput 1.3.6.1.4.1.1166.6.1.2.33.3.2.2
The value of this object provides the label of the RF Input Control Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

ea1000enumRfInput 1.3.6.1.4.1.1166.6.1.2.33.3.2.3
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

ea1000valueRfInput 1.3.6.1.4.1.1166.6.1.2.33.3.2.4
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

ea1000stateflagRfInput 1.3.6.1.4.1.1166.6.1.2.33.3.2.5
The value of this object provides the state of the RF Input Control Digital parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

ea1000labelOptOutput 1.3.6.1.4.1.1166.6.1.2.33.3.2.6
The value of this object provides the label of the Optical Output Control Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

ea1000enumOptOutput 1.3.6.1.4.1.1166.6.1.2.33.3.2.7
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

ea1000valueOptOutput 1.3.6.1.4.1.1166.6.1.2.33.3.2.8
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

ea1000stateflagOptOutput 1.3.6.1.4.1.1166.6.1.2.33.3.2.9
The value of this object provides the ea1000state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

ea1000labelLaserMode 1.3.6.1.4.1.1166.6.1.2.33.3.2.10
The value of this object provides the label of the Laser Mode Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

ea1000enumLaserMode 1.3.6.1.4.1.1166.6.1.2.33.3.2.11
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

ea1000valueLaserMode 1.3.6.1.4.1.1166.6.1.2.33.3.2.12
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER preset(1), set(2), setEquate(3), manual(4), manualEquate(5)  

ea1000stateflagLaserMode 1.3.6.1.4.1.1166.6.1.2.33.3.2.13
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

ea1000labelAttenSetting 1.3.6.1.4.1.1166.6.1.2.33.3.2.14
The value of this object provides the label of the Attenuation Setting Ditital Parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

ea1000enumAttenSetting 1.3.6.1.4.1.1166.6.1.2.33.3.2.15
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

ea1000valueAttenSetting 1.3.6.1.4.1.1166.6.1.2.33.3.2.16
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER attn0pt0(1), attn0pt5(2), attn1pt0(3), attn1pt5(4), attn2pt0(5), attn2pt5(6), attn3pt0(7), attn3pt5(8), attn4pt0(9), attn4pt5(10), attn5pt0(11), attn5pt5(12), attn6pt0(13), attn6pt5(14), attn7pt0(15), attn7pt5(16), attn8pt0(17), attn8pt5(18), attn9pt0(19), attn9pt5(20), attn10pt0(21), attn10pt5(22), attn11pt0(23), attn11pt5(24), attn12pt0(25)  

ea1000stateflagAttenSetting 1.3.6.1.4.1.1166.6.1.2.33.3.2.17
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

ea1000labelLaserSecMode 1.3.6.1.4.1.1166.6.1.2.33.3.2.18
The value of this object provides the label of the Laser Secondary Mode Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

ea1000enumLaserSecMode 1.3.6.1.4.1.1166.6.1.2.33.3.2.19
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

ea1000valueLaserSecMode 1.3.6.1.4.1.1166.6.1.2.33.3.2.20
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER cw(1), video(2)  

ea1000stateflagLaserSecMode 1.3.6.1.4.1.1166.6.1.2.33.3.2.21
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

ea1000labelVideoOffset 1.3.6.1.4.1.1166.6.1.2.33.3.2.22
The value of this object provides the label of the Video Offset Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

ea1000enumVideoOffset 1.3.6.1.4.1.1166.6.1.2.33.3.2.23
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1..
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

ea1000valueVideoOffset 1.3.6.1.4.1.1166.6.1.2.33.3.2.24
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER minus1dB(1), minus2dB(2), minus3dB(3), minus4dB(4), minus5dB(5)  

ea1000stateflagVideoOffset 1.3.6.1.4.1.1166.6.1.2.33.3.2.25
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

ea1000labelFactoryDefault 1.3.6.1.4.1.1166.6.1.2.33.3.2.26
The value of this object provides the label of the Factory Default Reset Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

ea1000enumFactoryDefault 1.3.6.1.4.1.1166.6.1.2.33.3.2.27
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

ea1000valueFactoryDefault 1.3.6.1.4.1.1166.6.1.2.33.3.2.28
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

ea1000stateflagFactoryDefault 1.3.6.1.4.1.1166.6.1.2.33.3.2.29
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

gx2ea1000StatusTableIndex 1.3.6.1.4.1.1166.6.1.2.33.4.3.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

ea1000labelBoot 1.3.6.1.4.1.1166.6.1.2.33.4.3.2
The value of this object provides the label of the Boot Status Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

ea1000valueBoot 1.3.6.1.4.1.1166.6.1.2.33.4.3.3
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

ea1000stateflagBoot 1.3.6.1.4.1.1166.6.1.2.33.4.3.4
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

ea1000labelFlash 1.3.6.1.4.1.1166.6.1.2.33.4.3.5
The value of this object provides the label of the Flash Status Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

ea1000valueFlash 1.3.6.1.4.1.1166.6.1.2.33.4.3.6
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

ea1000stateflagFlash 1.3.6.1.4.1.1166.6.1.2.33.4.3.7
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

ea1000labelFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.33.4.3.8
The value of this object provides the label of the Factory Data CRC Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

ea1000valueFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.33.4.3.9
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

ea1000stateflagFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.33.4.3.10
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

ea1000labelLaserDataCRC 1.3.6.1.4.1.1166.6.1.2.33.4.3.11
The value of this object provides the label of the Laser Data CRC Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

ea1000valueLaserDataCRC 1.3.6.1.4.1.1166.6.1.2.33.4.3.12
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

ea1000stateflagLaserDataCRC 1.3.6.1.4.1.1166.6.1.2.33.4.3.13
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

ea1000labelAlarmDataCrc 1.3.6.1.4.1.1166.6.1.2.33.4.3.14
The value of this object provides the label of the Alarm Data Crc parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

ea1000valueAlarmDataCrc 1.3.6.1.4.1.1166.6.1.2.33.4.3.15
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

ea1000stateflagAlarmDataCrc 1.3.6.1.4.1.1166.6.1.2.33.4.3.16
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

ea1000labelRFInputStatus 1.3.6.1.4.1.1166.6.1.2.33.4.3.17
The value of this object provides the label of the RF Input Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

ea1000valueRFInputStatus 1.3.6.1.4.1.1166.6.1.2.33.4.3.18
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

ea1000stateflagRFInputStatus 1.3.6.1.4.1.1166.6.1.2.33.4.3.19
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

gx2ea1000FactoryTableIndex 1.3.6.1.4.1.1166.6.1.2.33.5.4.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

ea1000bootControlByteValue 1.3.6.1.4.1.1166.6.1.2.33.5.4.2
The value of this object indicates which bank the firmware is currently being boot from.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ea1000bootStatusByteValue 1.3.6.1.4.1.1166.6.1.2.33.5.4.3
This object indicates the status of the last boot
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ea1000bank1CRCValue 1.3.6.1.4.1.1166.6.1.2.33.5.4.4
This object provides the CRC code of bank 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ea1000bank2CRCValue 1.3.6.1.4.1.1166.6.1.2.33.5.4.5
This object provides the CRC code of bank 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ea1000prgEEPROMByteValue 1.3.6.1.4.1.1166.6.1.2.33.5.4.6
This object indicates if the EEPROM has been programmed
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ea1000factoryCRCValue 1.3.6.1.4.1.1166.6.1.2.33.5.4.7
This object provides the CRC code for the Factory data.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ea1000calculateCRCValue 1.3.6.1.4.1.1166.6.1.2.33.5.4.8
This object indicates which of the Emnums will have the CRC calculated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER factory(1), laserData(2), alarm(3)  

ea1000hourMeterValue 1.3.6.1.4.1.1166.6.1.2.33.5.4.9
This object provides the hour meter reading of the module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ea1000flashPrgCntAValue 1.3.6.1.4.1.1166.6.1.2.33.5.4.10
This object provides the number of times Bank 1 flash has been programmed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ea1000flashPrgCntBValue 1.3.6.1.4.1.1166.6.1.2.33.5.4.11
This object provides the number of times Bank 1 flash has been programmed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ea1000flashBankARevValue 1.3.6.1.4.1.1166.6.1.2.33.5.4.12
This object provides the revision of flash bank 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

ea1000flashBankBRevValue 1.3.6.1.4.1.1166.6.1.2.33.5.4.13
This object provides the revision of flash bank 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

trapEA1000ConfigChangeInteger 1
This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE    

trapEA1000ConfigChangeDisplayString 2
This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE    

trapEA1000RFInputAlarm 3
This trap is issued when the Laser Modules RF input parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapEA1000RFOverloadAlarm 4
This trap is issued when the Laser Modules RF overload parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapEA1000RFOffsetAlarm 5
This trap is issued when the Laser Modules RF Offset parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapEA1000OpticalPowerAlarm 6
This trap is issued when the Laser Modules Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapEA1000LaserBiasAlarm 7
This trap is issued when the Laser Bias parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapEA1000LaserTempAlarm 8
This trap is issued when the Laser Temperature parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapEA1000TECCurrentAlarm 9
This trap is issued when the Laser Modules TEC Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapEA1000Fan1SpeedAlarm 10
This trap is issued when the Laser Modules Fan 1 Speed parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapEA1000Fan2SpeedAlarm 11
This trap is issued when the Laser Modules Fan 2 Speed parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapEA100012vAlarm 12
This trap is issued when the Laser Modules 12 Volt parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapEA1000ModuleTempAlarm 13
This trap is issued when the Laser Module Temperature goes out of range.
TRAP-TYPE    

trapEA1000FlashAlarm 14
This trap is issued when the Laser Modules detects an error during Flash memory operations.
TRAP-TYPE    

trapEA1000LaserBiasCntLoopAlarm 15
This trap is issued when the Laser Modules detects an error in its Laser Bias control loop operation.
TRAP-TYPE    

trapEA1000BankBootAlarm 16
This trap is issued when the Laser Modules detects an error while booting from bank 0 or bank 1.
TRAP-TYPE    

trapEA1000LaserBiasCntLoopInitAlarm 17
This trap is issued when the Laser Bias Control loop init fails.
TRAP-TYPE    

trapEA1000RFParamInitAlarm 18
This trap is issued when the RF parameter Init fails.
TRAP-TYPE    

trapEA1000TECParamInitAlarm 19
This trap is issued when the TEC Parameter Init fails.
TRAP-TYPE    

trapEA1000AttnTableInitAlarm 20
This trap is issued when the Attenuator Table Init fails.
TRAP-TYPE    

trapEA1000PowerMeterTableInitAlarm 21
This trap is issued when the Power Meter Table Init fails.
TRAP-TYPE    

trapEA1000LaserDataCRCAlarm 22
This trap is issued when the Laser Data CRC is incorrect.
TRAP-TYPE    

trapEA1000AlarmDataCRCAlarm 23
This trap is issued when the Alarm Data CRC is incorrect.
TRAP-TYPE    

trapEA1000FactoryDataCRCAlarm 24
This trap is issued when the Factory Data CRC is incorrect.
TRAP-TYPE    

trapEA1000UserRFOffAlarm 25
This trap is issued when the the User RF is turned off.
TRAP-TYPE    

trapEA1000UserOpticalOffAlarm 26
This trap is issued when the User Optical Power is turned off.
TRAP-TYPE    

trapEA1000ResetFactoryDefaultAlarm 27
This trap is issued when the Factory Default Reset occurs.
TRAP-TYPE