OMNI-gx2CM-MIB

File: OMNI-gx2CM-MIB.mib (110174 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC1213-MIB
RFC-1215 NLS-BBNIDENT-MIB GX2HFC-MIB
NLSBBN-TRAPS-MIB

Imported symbols

IpAddress TimeTicks Counter
OBJECT-TYPE sysUpTime DisplayString
TRAP-TYPE gi motproxies
gx2Cm trapIdentifier trapNetworkElemModelNumber
trapNetworkElemSerialNum trapPerceivedSeverity trapNetworkElemOperState
trapNetworkElemAlarmStatus trapNetworkElemAdminState trapNetworkElemAvailStatus
trapText trapNETrapLastTrapTimeStamp trapChangedObjectId
trapChangedValueInteger trapChangedValueDisplayString

Defined Types

Float  
Counter    

Gx2cmAnalogEntry  
SEQUENCE    
  gx2cmTableIndex INTEGER
  labelModTemp DisplayString Size(0..80)
  uomModTemp DisplayString Size(0..80)
  majorHighModTemp Float
  majorLowModTemp Float
  minorHighModTemp Float
  minorLowModTemp Float
  currentValueModTemp Float
  stateFlagModTemp INTEGER
  minValueModTemp Float
  maxValueModTemp Float
  alarmStateModTemp INTEGER

Gx2cmDigitalEntry  
SEQUENCE    
  gx2cmDigitalTableIndex INTEGER
  labelRemoteLocal DisplayString Size(0..80)
  enumRemoteLocal DisplayString Size(0..80)
  valueRemoteLocal INTEGER
  stateFlagRemoteLocal INTEGER
  labelResetSlot DisplayString Size(0..80)
  enumResetSlot DisplayString Size(0..80)
  valueResetSlot INTEGER
  stateResetSlot INTEGER
  labelIdShelf DisplayString Size(0..80)
  enumIdShelf DisplayString Size(0..80)
  valueIdShelf INTEGER
  stateFlagIdShelf INTEGER
  labelResetAlarm DisplayString Size(0..80)
  enumResetAlarm DisplayString Size(0..80)
  valueResetAlarm INTEGER
  stateFlagResetAlarm INTEGER

Gx2cmStatusEntry  
SEQUENCE    
  gx2cmStatusTableIndex INTEGER
  labelShelfAlarm DisplayString Size(0..80)
  valueShelfAlarm INTEGER
  stateShelfAlarm INTEGER
  labelDataCrc DisplayString Size(0..80)
  valueDataCrc INTEGER
  stateDataCrc INTEGER
  labelFlashStatus DisplayString Size(0..80)
  valueFlashStatus INTEGER
  stateFlashStatus INTEGER
  labelBootStatus DisplayString Size(0..80)
  valueBootStatus INTEGER
  stateBootStatus INTEGER
  labelAlmLimCrc DisplayString Size(0..80)
  valueAlmLimCrc INTEGER
  stateAlmLimCrc INTEGER

Gx2cmFactoryEntry  
SEQUENCE    
  gx2cmFactoryTableIndex INTEGER
  bootControlByte INTEGER
  bootStatusByte INTEGER
  bank0CRC INTEGER
  bank1CRC INTEGER
  prgEEPROMByte INTEGER
  factoryCRC INTEGER
  calculateCRC INTEGER
  hourMeter INTEGER
  flashPrgCnt0 INTEGER
  flashPrgCnt1 INTEGER
  flashBank0 DisplayString Size(0..80)
  flashBank1 DisplayString Size(0..80)
  localMacAdd DisplayString Size(0..80)
  netWorkMacAdd DisplayString Size(0..80)

Gx2cmNetworkEntry  
SEQUENCE    
  gx2cmNetworkTableIndex INTEGER
  labelLocalEthIPAdd DisplayString Size(0..80)
  valueLocalEthIPAdd DisplayString Size(0..80)
  labelLocalEthMask DisplayString Size(0..80)
  valueLocalEthMask DisplayString Size(0..80)
  labelNetworkEthAdd DisplayString Size(0..80)
  valueNetworkEthAdd DisplayString Size(0..80)
  labelNetworkEthMask DisplayString Size(0..80)
  valueNetworkEthMask DisplayString Size(0..80)
  labelShelfSerialNum DisplayString Size(0..80)
  valueShelfSerialNum DisplayString Size(0..80)
  labelGateWayIPAdd DisplayString Size(0..80)
  valueGateWayIPAdd DisplayString Size(0..80)
  labelTrapDestination DisplayString Size(0..80)
  valueTrapDestination DisplayString Size(0..80)
  labelTFTPserver DisplayString Size(0..80)
  valueTFTPserver DisplayString Size(0..80)
  labelTrap2Destination DisplayString Size(0..80)
  valueTrap2Destination DisplayString Size(0..80)
  labelTrap3Destination DisplayString Size(0..80)
  valueTrap3Destination DisplayString Size(0..80)
  labelTrap4Destination DisplayString Size(0..80)
  valueTrap4Destination DisplayString Size(0..80)
  labelTrap5Destination DisplayString Size(0..80)
  valueTrap5Destination DisplayString Size(0..80)
  labelISDNMode DisplayString Size(0..80)
  valueISDNMode INTEGER
  labelISDNModemIPAddress DisplayString Size(0..80)
  valueISDNModemIPAddress DisplayString Size(0..80)
  labelISDNTrapTimeout DisplayString Size(0..80)
  valueISDNTrapTimeout INTEGER
  labelISDNPingTimeout DisplayString Size(0..80)
  valueISDNPingTimeout INTEGER
  labelISDNBackoffTimer DisplayString Size(0..80)
  valueISDNBackoffTimer INTEGER

Gx2cmAMCEntry  
SEQUENCE    
  gx2cmAMCTableIndex INTEGER
  valueAMCslot1 INTEGER
  serialAMCslot1 DisplayString Size(0..80)
  agentIDAMCslot1 INTEGER
  valueAMCslot2 INTEGER
  serialAMCslot2 DisplayString Size(0..80)
  agentIDAMCslot2 INTEGER
  valueAMCslot3 INTEGER
  serialAMCslot3 DisplayString Size(0..80)
  agentIDAMCslot3 INTEGER
  valueAMCslot4 INTEGER
  serialAMCslot4 DisplayString Size(0..80)
  agentIDAMCslot4 INTEGER
  valueAMCslot5 INTEGER
  serialAMCslot5 DisplayString Size(0..80)
  agentIDAMCslot5 INTEGER
  valueAMCslot6 INTEGER
  serialAMCslot6 DisplayString Size(0..80)
  agentIDAMCslot6 INTEGER
  valueAMCslot7 INTEGER
  serialAMCslot7 DisplayString Size(0..80)
  agentIDAMCslot7 INTEGER
  valueAMCslot8 INTEGER
  serialAMCslot8 DisplayString Size(0..80)
  agentIDAMCslot8 INTEGER
  valueAMCslot9 INTEGER
  serialAMCslot9 DisplayString Size(0..80)
  agentIDAMCslot9 INTEGER
  valueAMCslot10 INTEGER
  serialAMCslot10 DisplayString Size(0..80)
  agentIDAMCslot10 INTEGER
  valueAMCslot11 INTEGER
  serialAMCslot11 DisplayString Size(0..80)
  agentIDAMCslot11 INTEGER
  valueAMCslot12 INTEGER
  serialAMCslot12 DisplayString Size(0..80)
  agentIDAMCslot12 INTEGER
  valueAMCslot13 INTEGER
  serialAMCslot13 DisplayString Size(0..80)
  agentIDAMCslot13 INTEGER
  valueAMCslot14 INTEGER
  serialAMCslot14 DisplayString Size(0..80)
  agentIDAMCslot14 INTEGER
  valueAMCslot15 INTEGER
  serialAMCslot15 DisplayString Size(0..80)
  agentIDAMCslot15 INTEGER
  valueAMCslot16 INTEGER
  serialAMCslot16 DisplayString Size(0..80)
  agentIDAMCslot16 INTEGER
  valueAMCslot17 INTEGER
  serialAMCslot17 DisplayString Size(0..80)
  agentIDAMCslot17 INTEGER
  valueAMCslot18 INTEGER
  serialAMCslot18 DisplayString Size(0..80)
  agentIDAMCslot18 INTEGER
  autoQuickSwapCnt INTEGER

Gx2cmSecurityEntry  
SEQUENCE    
  gx2cmSecurityTableIndex INTEGER
  labelSecurityMode DisplayString Size(0..80)
  enumSecurityMode DisplayString Size(0..80)
  valueSecurityMode INTEGER
  stateSecurityMode INTEGER
  labelPassword DisplayString Size(0..80)
  valuePassword DisplayString Size(0..80)
  statePassword INTEGER
  labelFactoryChgString DisplayString Size(0..80)
  valueFactoryChgString DisplayString Size(0..80)
  stateFactoryChgString INTEGER
  labelOperatorChgString DisplayString Size(0..80)
  valueOperatorChgString DisplayString Size(0..80)
  stateOperatorChgString INTEGER
  labelReadOnlyChgString DisplayString Size(0..80)
  valueReadOnlyChgString DisplayString Size(0..80)
  stateReadOnlyChgString INTEGER
  labelRemoteOnlyChgString DisplayString Size(0..80)
  valueRemoteOnlyChgString DisplayString Size(0..80)
  stateRemoteOnlyChgString INTEGER
  labelLocalOnlyChgString DisplayString Size(0..80)
  valueLocalOnlyChgString DisplayString Size(0..80)
  stateLocalOnlyChgString INTEGER

Gx2cmDiagnosticEntry  
SEQUENCE    
  gx2cmDiagnosticTableIndex INTEGER
  ledTestValue INTEGER
  bpTestCnt INTEGER
  successTransSlot1 INTEGER
  successTransSlot2 INTEGER
  successTransSlot3 INTEGER
  successTransSlot4 INTEGER
  successTransSlot5 INTEGER
  successTransSlot6 INTEGER
  successTransSlot7 INTEGER
  successTransSlot8 INTEGER
  successTransSlot9 INTEGER
  successTransSlot10 INTEGER
  successTransSlot11 INTEGER
  successTransSlot12 INTEGER
  successTransSlot13 INTEGER
  successTransSlot14 INTEGER
  successTransSlot15 INTEGER
  successTransSlot16 INTEGER
  successTransSlot17 INTEGER
  successTransSlot18 INTEGER
  failureTransSlot1 INTEGER
  failureTransSlot2 INTEGER
  failureTransSlot3 INTEGER
  failureTransSlot4 INTEGER
  failureTransSlot5 INTEGER
  failureTransSlot6 INTEGER
  failureTransSlot7 INTEGER
  failureTransSlot8 INTEGER
  failureTransSlot9 INTEGER
  failureTransSlot10 INTEGER
  failureTransSlot11 INTEGER
  failureTransSlot12 INTEGER
  failureTransSlot13 INTEGER
  failureTransSlot14 INTEGER
  failureTransSlot15 INTEGER
  failureTransSlot16 INTEGER
  failureTransSlot17 INTEGER
  failureTransSlot18 INTEGER
  fanTestMode INTEGER
  fanControl INTEGER
  relayTestMode INTEGER
  relayControl INTEGER
  slotPollMode INTEGER
  bootCount INTEGER
  objectTableData DisplayString Size(0..80)
  setSysTime INTEGER

Gx2cmDownloadEntry  
SEQUENCE    
  gx2cmDownloadTableIndex INTEGER
  downloadValue INTEGER
  autoDownloadReset INTEGER
  downloadFilename DisplayString Size(0..80)
  downloadState INTEGER
  switchFwBank INTEGER

CmTrapHistoryEntry  
SEQUENCE    
  cmTrapHistoryTableIndex INTEGER
  netrapId INTEGER
  netrapNetworkElemModelNumber DisplayString Size(0..80)
  netrapNetworkElemSerialNum DisplayString Size(0..80)
  netrapPerceivedSeverity INTEGER
  netrapNetworkElemOperState INTEGER
  netrapNetworkElemAlarmStatus INTEGER
  netrapNetworkElemAdminState INTEGER
  netrapNetworkElemAvailStatus INTEGER
  netrapText DisplayString Size(0..80)
  netrapLastTrapTimeStamp TimeTicks
  netrapChangedObjectId DisplayString Size(0..80)
  netrapAdditionalInfoInteger1 INTEGER
  netrapAdditionalInfoInteger2 INTEGER
  netrapAdditionalInfoInteger3 INTEGER
  netrapChangedValueDisplayString DisplayString Size(0..80)
  netrapChangedValueOID DisplayString Size(0..80)
  netrapChangedValueIpAddress INTEGER
  netrapChangedValueInteger INTEGER

Defined Values

gx2cmDescriptor 1.3.6.1.4.1.1166.6.1.2.3.1
OBJECT IDENTIFIER    

gx2cmFactoryTable 1.3.6.1.4.1.1166.6.1.2.3.2
This table contains gx2Cm specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2cmFactoryEntry

gx2cmFactoryEntry 1.3.6.1.4.1.1166.6.1.2.3.2.1
This list contains Factory data and the associated parameter descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2cmFactoryEntry  

gx2cmNetworkTable 1.3.6.1.4.1.1166.6.1.2.3.3
This table contains gx2Cm specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2cmNetworkEntry

gx2cmNetworkEntry 1.3.6.1.4.1.1166.6.1.2.3.3.2
This list contains Network parameters and the associated parameter descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2cmNetworkEntry  

gx2cmAnalogTable 1.3.6.1.4.1.1166.6.1.2.3.4
This table contains gx2Cm specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2cmAnalogEntry

gx2cmAnalogEntry 1.3.6.1.4.1.1166.6.1.2.3.4.3
This list contains analog parameters and the associated parameter descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2cmAnalogEntry  

gx2cmDigitalTable 1.3.6.1.4.1.1166.6.1.2.3.5
This table contains gx2Cm specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2cmDigitalEntry

gx2cmDigitalEntry 1.3.6.1.4.1.1166.6.1.2.3.5.4
This list contains digital parameters and the associated parameter descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2cmDigitalEntry  

gx2cmStatusTable 1.3.6.1.4.1.1166.6.1.2.3.6
This table contains gx2Cm specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2cmStatusEntry

gx2cmStatusEntry 1.3.6.1.4.1.1166.6.1.2.3.6.5
This list contains status parameters and the associated parameter descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2cmStatusEntry  

gx2cmAMCTable 1.3.6.1.4.1.1166.6.1.2.3.7
This table contains gx2Cm specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2cmAMCEntry

gx2cmAMCEntry 1.3.6.1.4.1.1166.6.1.2.3.7.6
This list contains the AMC parameters and the associated parameter descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2cmAMCEntry  

gx2cmSecurityTable 1.3.6.1.4.1.1166.6.1.2.3.8
This table contains gx2Cm specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2cmSecurityEntry

gx2cmSecurityEntry 1.3.6.1.4.1.1166.6.1.2.3.8.7
This list contains Security parameters and the associated parameter descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2cmSecurityEntry  

gx2cmDiagnosticTable 1.3.6.1.4.1.1166.6.1.2.3.9
This table contains gx2Cm specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2cmDiagnosticEntry

gx2cmDiagnosticEntry 1.3.6.1.4.1.1166.6.1.2.3.9.8
This list contains Diagnostic parameters and the associated parameter descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2cmDiagnosticEntry  

gx2cmDownloadTable 1.3.6.1.4.1.1166.6.1.2.3.10
This table contains gx2Cm specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2cmDownloadEntry

gx2cmDownloadEntry 1.3.6.1.4.1.1166.6.1.2.3.10.9
This list contains Download parameters and the associated parameter descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2cmDownloadEntry  

cmTrapHistoryTable 1.3.6.1.4.1.1166.6.1.2.3.11
This table contains the trap specific parameters.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CmTrapHistoryEntry

cmTrapHistoryEntry 1.3.6.1.4.1.1166.6.1.2.3.11.10
This list contains Trap History parameters and the associated parameter descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  CmTrapHistoryEntry  

gx2cmTableIndex 1.3.6.1.4.1.1166.6.1.2.3.4.3.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

labelModTemp 1.3.6.1.4.1.1166.6.1.2.3.4.3.2
The value of this object provides the label of the Module Temp parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

uomModTemp 1.3.6.1.4.1.1166.6.1.2.3.4.3.3
The value of this object provides the Unit of Measure of the Module Temp parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

majorHighModTemp 1.3.6.1.4.1.1166.6.1.2.3.4.3.4
The value of this object provides the Major High alarm value of the Module Temp parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

majorLowModTemp 1.3.6.1.4.1.1166.6.1.2.3.4.3.5
The value of this object provides the Major Low alarm value of the Module Temp parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

minorHighModTemp 1.3.6.1.4.1.1166.6.1.2.3.4.3.6
The value of this object provides the Minor High alarm value of the Module Temp parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

minorLowModTemp 1.3.6.1.4.1.1166.6.1.2.3.4.3.7
The value of this object provides the Minor Low alarm value of the Module Temp parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

currentValueModTemp 1.3.6.1.4.1.1166.6.1.2.3.4.3.8
The value of this object provides the Current value of the Module Temp parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

stateFlagModTemp 1.3.6.1.4.1.1166.6.1.2.3.4.3.9
The value of this object provides the state of the Module Temp parameter. (0-Hidden 1-Read-Only, 2-Updateable)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

minValueModTemp 1.3.6.1.4.1.1166.6.1.2.3.4.3.10
The value of this object provides the minimum value the Module Temp parameter can achive.
Status: optional Access: read-only
OBJECT-TYPE    
  Float  

maxValueModTemp 1.3.6.1.4.1.1166.6.1.2.3.4.3.11
The value of this object provides the maximum value the Module Temp parameter can achive.
Status: optional Access: read-only
OBJECT-TYPE    
  Float  

alarmStateModTemp 1.3.6.1.4.1.1166.6.1.2.3.4.3.12
The value of this object provides the curent alarm state of the Module Temp Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

gx2cmDigitalTableIndex 1.3.6.1.4.1.1166.6.1.2.3.5.4.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

labelRemoteLocal 1.3.6.1.4.1.1166.6.1.2.3.5.4.2
The value of this object provides the label of the Remote Local Control Digital parameter.
Status: obsolete Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

enumRemoteLocal 1.3.6.1.4.1.1166.6.1.2.3.5.4.3
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated value is separated by a common. The first value has a enumerated value of 1.
Status: obsolete Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

valueRemoteLocal 1.3.6.1.4.1.1166.6.1.2.3.5.4.4
The value of this object is the current value of the parameter.
Status: obsolete Access: read-write
OBJECT-TYPE    
  INTEGER local(1), remote(2)  

stateFlagRemoteLocal 1.3.6.1.4.1.1166.6.1.2.3.5.4.5
The value of this object provides the state of the Remote Local Control Digital parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: obsolete Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

labelResetSlot 1.3.6.1.4.1.1166.6.1.2.3.5.4.6
The value of this object provides the label of the Reset Slot Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

enumResetSlot 1.3.6.1.4.1.1166.6.1.2.3.5.4.7
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated value is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

valueResetSlot 1.3.6.1.4.1.1166.6.1.2.3.5.4.8
The value of this object is the current value of the parameter. A write to this object will casue a hardware reset. 0-control module 1-18 selected slot.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

stateResetSlot 1.3.6.1.4.1.1166.6.1.2.3.5.4.9
The value of this object provides the state of the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

labelIdShelf 1.3.6.1.4.1.1166.6.1.2.3.5.4.10
The value of this object provides the label of the identify shelf Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

enumIdShelf 1.3.6.1.4.1.1166.6.1.2.3.5.4.11
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated value is separated by a common. The first value has a enumerated value of 1..
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

valueIdShelf 1.3.6.1.4.1.1166.6.1.2.3.5.4.12
The value of this object is the current value of the parameter. Writing any non zero value to this parameter will casue the CM to blink its front panel LED.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

stateFlagIdShelf 1.3.6.1.4.1.1166.6.1.2.3.5.4.13
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

labelResetAlarm 1.3.6.1.4.1.1166.6.1.2.3.5.4.14
The value of this object provides the label of the Reset Alarms Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

enumResetAlarm 1.3.6.1.4.1.1166.6.1.2.3.5.4.15
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated value is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

valueResetAlarm 1.3.6.1.4.1.1166.6.1.2.3.5.4.16
The value of this object is the current value of the parameter. Writing any non-zero value to this object will case the CM to reset shelf alarm processing.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

stateFlagResetAlarm 1.3.6.1.4.1.1166.6.1.2.3.5.4.17
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

gx2cmStatusTableIndex 1.3.6.1.4.1.1166.6.1.2.3.6.5.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

labelShelfAlarm 1.3.6.1.4.1.1166.6.1.2.3.6.5.2
The value of this object provides the label of the Shelf Alarm Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

valueShelfAlarm 1.3.6.1.4.1.1166.6.1.2.3.6.5.3
The value of this object provides the current status of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

stateShelfAlarm 1.3.6.1.4.1.1166.6.1.2.3.6.5.4
The value of this object provides the current state of the parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

labelDataCrc 1.3.6.1.4.1.1166.6.1.2.3.6.5.5
The value of this object provides the label of the Data CRC parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

valueDataCrc 1.3.6.1.4.1.1166.6.1.2.3.6.5.6
The value of this object provides the current status of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

stateDataCrc 1.3.6.1.4.1.1166.6.1.2.3.6.5.7
The value of this object provides the current state of the parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

labelFlashStatus 1.3.6.1.4.1.1166.6.1.2.3.6.5.8
The value of this object provides the label of the Flash Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

valueFlashStatus 1.3.6.1.4.1.1166.6.1.2.3.6.5.9
The value of this object provides the current status of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

stateFlashStatus 1.3.6.1.4.1.1166.6.1.2.3.6.5.10
The value of this object provides the current state of the parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

labelBootStatus 1.3.6.1.4.1.1166.6.1.2.3.6.5.11
The value of this object provides the label of the Boot Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

valueBootStatus 1.3.6.1.4.1.1166.6.1.2.3.6.5.12
The value of this object provides the current status of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

stateBootStatus 1.3.6.1.4.1.1166.6.1.2.3.6.5.13
The value of this object provides the current state of the parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

labelAlmLimCrc 1.3.6.1.4.1.1166.6.1.2.3.6.5.14
The value of this object provides the label of the Alarm limit CRC parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

valueAlmLimCrc 1.3.6.1.4.1.1166.6.1.2.3.6.5.15
The value of this object provides the current status of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

stateAlmLimCrc 1.3.6.1.4.1.1166.6.1.2.3.6.5.16
The value of this object provides the current state of the parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

gx2cmFactoryTableIndex 1.3.6.1.4.1.1166.6.1.2.3.2.1.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

bootControlByte 1.3.6.1.4.1.1166.6.1.2.3.2.1.2
The value of this object indicates which bank the firmware is currently being boot from.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

bootStatusByte 1.3.6.1.4.1.1166.6.1.2.3.2.1.3
This object indicates the status of the last boot
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

bank0CRC 1.3.6.1.4.1.1166.6.1.2.3.2.1.4
This object provides the CRC code of bank 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

bank1CRC 1.3.6.1.4.1.1166.6.1.2.3.2.1.5
This object provides the CRC code of bank 2.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

prgEEPROMByte 1.3.6.1.4.1.1166.6.1.2.3.2.1.6
This object indicates if the EEPROM has been programmed
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

factoryCRC 1.3.6.1.4.1.1166.6.1.2.3.2.1.7
This object provides the CRC code for the Factory data.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

calculateCRC 1.3.6.1.4.1.1166.6.1.2.3.2.1.8
This object provides the CRC value of the fimware.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

hourMeter 1.3.6.1.4.1.1166.6.1.2.3.2.1.9
This object provides the hour meter reading of the module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

flashPrgCnt0 1.3.6.1.4.1.1166.6.1.2.3.2.1.10
This object provides the number of times the flash has been programmed on side A.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

flashPrgCnt1 1.3.6.1.4.1.1166.6.1.2.3.2.1.11
This object provides the number of times the flash has been programmed on side B.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

flashBank0 1.3.6.1.4.1.1166.6.1.2.3.2.1.12
This object provides the firmware revision of the firmware in bank 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

flashBank1 1.3.6.1.4.1.1166.6.1.2.3.2.1.13
This object provides the firmware revision of the firmware in bank 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

localMacAdd 1.3.6.1.4.1.1166.6.1.2.3.2.1.14
This object provides the local mac address number
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

netWorkMacAdd 1.3.6.1.4.1.1166.6.1.2.3.2.1.15
This object provides the network mac address number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

gx2cmNetworkTableIndex 1.3.6.1.4.1.1166.6.1.2.3.3.2.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

labelLocalEthIPAdd 1.3.6.1.4.1.1166.6.1.2.3.3.2.2
This object provides the label for the Ethernet IP Address field.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

valueLocalEthIPAdd 1.3.6.1.4.1.1166.6.1.2.3.3.2.3
This object provides the Local Ethernet IP Address for the Control Module.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..80)  

labelLocalEthMask 1.3.6.1.4.1.1166.6.1.2.3.3.2.4
This object provides the label for the Local Ethernet Mask field.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

valueLocalEthMask 1.3.6.1.4.1.1166.6.1.2.3.3.2.5
This object provides the Local Ethernet Mask value.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..80)  

labelNetworkEthAdd 1.3.6.1.4.1.1166.6.1.2.3.3.2.6
This object provides the label for the Network Ethernet Address .
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

valueNetworkEthAdd 1.3.6.1.4.1.1166.6.1.2.3.3.2.7
This object provides the value of the Network Ethernet Address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..80)  

labelNetworkEthMask 1.3.6.1.4.1.1166.6.1.2.3.3.2.8
This object provides the label for the Network Mask Address.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

valueNetworkEthMask 1.3.6.1.4.1.1166.6.1.2.3.3.2.9
This object provides the value of the Network Mask Address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..80)  

labelShelfSerialNum 1.3.6.1.4.1.1166.6.1.2.3.3.2.10
This object provides the label for the Shelf Serial Number.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

valueShelfSerialNum 1.3.6.1.4.1.1166.6.1.2.3.3.2.11
This object provides the value for the Shelf Serial Number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

labelGateWayIPAdd 1.3.6.1.4.1.1166.6.1.2.3.3.2.12
This object provides the label for the Gateway IP address.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

valueGateWayIPAdd 1.3.6.1.4.1.1166.6.1.2.3.3.2.13
This object provides the value for the IP address for the Gateway.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..80)  

labelTrapDestination 1.3.6.1.4.1.1166.6.1.2.3.3.2.14
This object provides the label the trap destination field.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

valueTrapDestination 1.3.6.1.4.1.1166.6.1.2.3.3.2.15
This object provides the address for the trap destination.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..80)  

labelTFTPserver 1.3.6.1.4.1.1166.6.1.2.3.3.2.16
This object provides the label the TFTP Server address field.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

valueTFTPserver 1.3.6.1.4.1.1166.6.1.2.3.3.2.17
This object provides the address for the TFTP Server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..80)  

labelTrap2Destination 1.3.6.1.4.1.1166.6.1.2.3.3.2.18
This object provides the label the second trap destination field.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

valueTrap2Destination 1.3.6.1.4.1.1166.6.1.2.3.3.2.19
This object provides the address for the second trap destination.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..80)  

labelTrap3Destination 1.3.6.1.4.1.1166.6.1.2.3.3.2.20
This object provides the label the third trap destination field.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

valueTrap3Destination 1.3.6.1.4.1.1166.6.1.2.3.3.2.21
This object provides the address for the third trap destination.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..80)  

labelTrap4Destination 1.3.6.1.4.1.1166.6.1.2.3.3.2.22
This object provides the label the fourth trap destination field.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

valueTrap4Destination 1.3.6.1.4.1.1166.6.1.2.3.3.2.23
This object provides the address for the fourth trap destination.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..80)  

labelTrap5Destination 1.3.6.1.4.1.1166.6.1.2.3.3.2.24
This object provides the label the fifth trap destination field.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

valueTrap5Destination 1.3.6.1.4.1.1166.6.1.2.3.3.2.25
This object provides the address for the fifth trap destination.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..80)  

labelISDNMode 1.3.6.1.4.1.1166.6.1.2.3.3.2.26
This object provides the label for the ISDN mode setting.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

valueISDNMode 1.3.6.1.4.1.1166.6.1.2.3.3.2.27
This object provides the value for the ISDN mode setting. In order to activate the ISDN feature, the user must set the ISDN mode to ON and provide a valid IP address. This address needs to be the IP address of the remote ISDN Modem.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

labelISDNModemIPAddress 1.3.6.1.4.1.1166.6.1.2.3.3.2.28
This object provides the label for the ISDN modem IP Address.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

valueISDNModemIPAddress 1.3.6.1.4.1.1166.6.1.2.3.3.2.29
This object provides the value for the ISDN modem IP Address. This Address is used by the control Module to ping the remote ISDN modem to determine if an ISDN connection is made. Only after a successful ping response to this address and the ISDN Modem Mode object is set to ON will the Control Module send traps. Factory default value is 0.0.0.0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..80)  

labelISDNTrapTimeout 1.3.6.1.4.1.1166.6.1.2.3.3.2.30
This object provides the label for the ISDN modem Timeout object.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

valueISDNTrapTimeout 1.3.6.1.4.1.1166.6.1.2.3.3.2.31
This object provides the value for the ISDN modem Timeout. The value of this object sets the time period that the communication link is open for sending traps. This timer is started when the first trap is issued. The factory default for this value is 2 minutes. Unit of measure is in seconds.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..3600  

labelISDNPingTimeout 1.3.6.1.4.1.1166.6.1.2.3.3.2.32
This object provides the label for the ISDN ping timeout object.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

valueISDNPingTimeout 1.3.6.1.4.1.1166.6.1.2.3.3.2.33
This object provides the value for the ISDN ping timeout. Factory default value is 500 ms. User should set this value in milli-second
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 100..5000  

labelISDNBackoffTimer 1.3.6.1.4.1.1166.6.1.2.3.3.2.34
This object provides the label for the ISDN backoff timer object.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

valueISDNBackoffTimer 1.3.6.1.4.1.1166.6.1.2.3.3.2.35
This object provides the value for the ISDN backoff timer. The value in this object is a hold period used to prevent traps from being sent. It is used to allow other chassis to have time to connect and communicate over the ISDN modems. This hold period starts after the valueISDNTrapTimeout period has expired. NOTE: The value of this object should be set to a value greater than the ISDN Modem's idle connection timeout period. This will allow the Modem to break the ISDN Connection. Factory default value is 2 min (120 sec). User should set this value in seconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..3600  

gx2cmSecurityTableIndex 1.3.6.1.4.1.1166.6.1.2.3.8.7.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

labelSecurityMode 1.3.6.1.4.1.1166.6.1.2.3.8.7.2
This object provides the label for the Current Security Mode.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

enumSecurityMode 1.3.6.1.4.1.1166.6.1.2.3.8.7.3
The value of this object represents the Enumeration values possible for the security mode parameter. Each Enumerated value is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

valueSecurityMode 1.3.6.1.4.1.1166.6.1.2.3.8.7.4
This object indicates the current Security Mode.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER read-only(1), operator-access(2), factory-access(3), remote-write-only(4), local-write-only(5)  

stateSecurityMode 1.3.6.1.4.1.1166.6.1.2.3.8.7.5
This object indicates the state of the Security Mode parameter .
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

labelPassword 1.3.6.1.4.1.1166.6.1.2.3.8.7.6
This object provides the label for the Password field.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

valuePassword 1.3.6.1.4.1.1166.6.1.2.3.8.7.7
This object provides the value for the Password.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..80)  

statePassword 1.3.6.1.4.1.1166.6.1.2.3.8.7.8
This object provides the state of the password field.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

labelFactoryChgString 1.3.6.1.4.1.1166.6.1.2.3.8.7.9
This object provides the lable for the Factory Change String field.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

valueFactoryChgString 1.3.6.1.4.1.1166.6.1.2.3.8.7.10
This object provides the value for the Factory Change String.
Status: mandatory Access: write-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

stateFactoryChgString 1.3.6.1.4.1.1166.6.1.2.3.8.7.11
This object provides the state of the Factory Change String field.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

labelOperatorChgString 1.3.6.1.4.1.1166.6.1.2.3.8.7.12
This object provides the lable for the Operator Change String field.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

valueOperatorChgString 1.3.6.1.4.1.1166.6.1.2.3.8.7.13
This object provides the value for the Operator Change String.
Status: mandatory Access: write-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

stateOperatorChgString 1.3.6.1.4.1.1166.6.1.2.3.8.7.14
This object provides the state of the Operator Change String field.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

labelReadOnlyChgString 1.3.6.1.4.1.1166.6.1.2.3.8.7.15
This object provides the lable for the Read Only Change String field.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

valueReadOnlyChgString 1.3.6.1.4.1.1166.6.1.2.3.8.7.16
This object provides the value for the Read Only Change String.
Status: mandatory Access: write-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

stateReadOnlyChgString 1.3.6.1.4.1.1166.6.1.2.3.8.7.17
This object provides the state of the Read Only Change String field.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

labelRemoteOnlyChgString 1.3.6.1.4.1.1166.6.1.2.3.8.7.18
This object provides the lable for the Remote Only Change String field.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

valueRemoteOnlyChgString 1.3.6.1.4.1.1166.6.1.2.3.8.7.19
This object provides the value for the Remote Only Change String.
Status: mandatory Access: write-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

stateRemoteOnlyChgString 1.3.6.1.4.1.1166.6.1.2.3.8.7.20
This object provides the state of the Remote Only Change String field.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

labelLocalOnlyChgString 1.3.6.1.4.1.1166.6.1.2.3.8.7.21
This object provides the lable for the Local Only Change String field.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

valueLocalOnlyChgString 1.3.6.1.4.1.1166.6.1.2.3.8.7.22
This object provides the value for the Local Only Change String.
Status: mandatory Access: write-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

stateLocalOnlyChgString 1.3.6.1.4.1.1166.6.1.2.3.8.7.23
This object provides the state of the Local Only Change String field.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

gx2cmAMCTableIndex 1.3.6.1.4.1.1166.6.1.2.3.7.6.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

valueAMCslot1 1.3.6.1.4.1.1166.6.1.2.3.7.6.2
This object provides control to enable or disable AMC for the current device in the slot.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2), force(3)  

serialAMCslot1 1.3.6.1.4.1.1166.6.1.2.3.7.6.3
This object provides the serial number for the AMC slot selected.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

agentIDAMCslot1 1.3.6.1.4.1.1166.6.1.2.3.7.6.4
This object provides the agentID of the AMC parameter for the selected slot.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

valueAMCslot2 1.3.6.1.4.1.1166.6.1.2.3.7.6.5
This object provides control to enable or disable AMC for the current device in the slot.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2), force(3)  

serialAMCslot2 1.3.6.1.4.1.1166.6.1.2.3.7.6.6
This object provides the serial number for the AMC slot selected.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

agentIDAMCslot2 1.3.6.1.4.1.1166.6.1.2.3.7.6.7
This object provides the agentID of the AMC parameter for the selected slot.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

valueAMCslot3 1.3.6.1.4.1.1166.6.1.2.3.7.6.8
This object provides control to enable or disable AMC for the current device in the slot.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2), force(3)  

serialAMCslot3 1.3.6.1.4.1.1166.6.1.2.3.7.6.9
This object provides the serial number for the AMC slot selected.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

agentIDAMCslot3 1.3.6.1.4.1.1166.6.1.2.3.7.6.10
This object provides the agentID of the AMC parameter for the selected slot.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

valueAMCslot4 1.3.6.1.4.1.1166.6.1.2.3.7.6.11
This object provides control to enable or disable AMC for the current device in the slot.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2), force(3)  

serialAMCslot4 1.3.6.1.4.1.1166.6.1.2.3.7.6.12
This object provides the serial number for the AMC slot selected.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

agentIDAMCslot4 1.3.6.1.4.1.1166.6.1.2.3.7.6.13
This object provides the agentID of the AMC parameter for the selected slot.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

valueAMCslot5 1.3.6.1.4.1.1166.6.1.2.3.7.6.14
This object provides control to enable or disable AMC for the current device in the slot.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2), force(3)  

serialAMCslot5 1.3.6.1.4.1.1166.6.1.2.3.7.6.15
This object provides the serial number for the AMC slot selected.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

agentIDAMCslot5 1.3.6.1.4.1.1166.6.1.2.3.7.6.16
This object provides the agentID of the AMC parameter for the selected slot.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

valueAMCslot6 1.3.6.1.4.1.1166.6.1.2.3.7.6.17
This object provides control to enable or disable AMC for the current device in the slot.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2), force(3)  

serialAMCslot6 1.3.6.1.4.1.1166.6.1.2.3.7.6.18
This object provides the serial number for the AMC slot selected.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

agentIDAMCslot6 1.3.6.1.4.1.1166.6.1.2.3.7.6.19
This object provides the agentID of the AMC parameter for the selected slot.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

valueAMCslot7 1.3.6.1.4.1.1166.6.1.2.3.7.6.20
This object provides control to enable or disable AMC for the current device in the slot.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2), force(3)  

serialAMCslot7 1.3.6.1.4.1.1166.6.1.2.3.7.6.21
This object provides the serial number for the AMC slot selected.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

agentIDAMCslot7 1.3.6.1.4.1.1166.6.1.2.3.7.6.22
This object provides the agentID of the AMC parameter for the selected slot.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

valueAMCslot8 1.3.6.1.4.1.1166.6.1.2.3.7.6.23
This object provides control to enable or disable AMC for the current device in the slot.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2), force(3)  

serialAMCslot8 1.3.6.1.4.1.1166.6.1.2.3.7.6.24
This object provides the serial number for the AMC slot selected.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

agentIDAMCslot8 1.3.6.1.4.1.1166.6.1.2.3.7.6.25
This object provides the agentID of the AMC parameter for the selected slot.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

valueAMCslot9 1.3.6.1.4.1.1166.6.1.2.3.7.6.26
This object provides control to enable or disable AMC for the current device in the slot.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2), force(3)  

serialAMCslot9 1.3.6.1.4.1.1166.6.1.2.3.7.6.27
This object provides the serial number for the AMC slot selected.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

agentIDAMCslot9 1.3.6.1.4.1.1166.6.1.2.3.7.6.28
This object provides the agentID of the AMC parameter for the selected slot.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

valueAMCslot10 1.3.6.1.4.1.1166.6.1.2.3.7.6.29
This object provides control to enable or disable AMC for the current device in the slot.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2), force(3)  

serialAMCslot10 1.3.6.1.4.1.1166.6.1.2.3.7.6.30
This object provides the serial number for the AMC slot selected.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

agentIDAMCslot10 1.3.6.1.4.1.1166.6.1.2.3.7.6.31
This object provides the agentID of the AMC parameter for the selected slot.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

valueAMCslot11 1.3.6.1.4.1.1166.6.1.2.3.7.6.32
This object provides control to enable or disable AMC for the current device in the slot.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2), force(3)  

serialAMCslot11 1.3.6.1.4.1.1166.6.1.2.3.7.6.33
This object provides the serial number for the AMC slot selected.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

agentIDAMCslot11 1.3.6.1.4.1.1166.6.1.2.3.7.6.34
This object provides the agentID of the AMC parameter for the selected slot.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

valueAMCslot12 1.3.6.1.4.1.1166.6.1.2.3.7.6.35
This object provides control to enable or disable AMC for the current device in the slot.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2), force(3)  

serialAMCslot12 1.3.6.1.4.1.1166.6.1.2.3.7.6.36
This object provides the serial number for the AMC slot selected.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

agentIDAMCslot12 1.3.6.1.4.1.1166.6.1.2.3.7.6.37
This object provides the agentID of the AMC parameter for the selected slot.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

valueAMCslot13 1.3.6.1.4.1.1166.6.1.2.3.7.6.38
This object provides control to enable or disable AMC for the current device in the slot.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2), force(3)  

serialAMCslot13 1.3.6.1.4.1.1166.6.1.2.3.7.6.39
This object provides the serial number for the AMC slot selected.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

agentIDAMCslot13 1.3.6.1.4.1.1166.6.1.2.3.7.6.40
This object provides the agentID of the AMC parameter for the selected slot.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

valueAMCslot14 1.3.6.1.4.1.1166.6.1.2.3.7.6.41
This object provides control to enable or disable AMC for the current device in the slot.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2), force(3)  

serialAMCslot14 1.3.6.1.4.1.1166.6.1.2.3.7.6.42
This object provides the serial number for the AMC slot selected.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

agentIDAMCslot14 1.3.6.1.4.1.1166.6.1.2.3.7.6.43
This object provides the agentID of the AMC parameter for the selected slot.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

valueAMCslot15 1.3.6.1.4.1.1166.6.1.2.3.7.6.44
This object provides control to enable or disable AMC for the current device in the slot.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2), force(3)  

serialAMCslot15 1.3.6.1.4.1.1166.6.1.2.3.7.6.45
This object provides the serial number for the AMC slot selected.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

agentIDAMCslot15 1.3.6.1.4.1.1166.6.1.2.3.7.6.46
This object provides the agentID of the AMC parameter for the selected slot.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

valueAMCslot16 1.3.6.1.4.1.1166.6.1.2.3.7.6.47
This object provides control to enable or disable AMC for the current device in the slot.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2), force(3)  

serialAMCslot16 1.3.6.1.4.1.1166.6.1.2.3.7.6.48
This object provides the serial number for the AMC slot selected.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

agentIDAMCslot16 1.3.6.1.4.1.1166.6.1.2.3.7.6.49
This object provides the agentID of the AMC parameter for the selected slot.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

valueAMCslot17 1.3.6.1.4.1.1166.6.1.2.3.7.6.50
This object provides control to enable or disable AMC for the current device in the slot.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2), force(3)  

serialAMCslot17 1.3.6.1.4.1.1166.6.1.2.3.7.6.51
This object provides the serial number for the AMC slot selected.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

agentIDAMCslot17 1.3.6.1.4.1.1166.6.1.2.3.7.6.52
This object provides the agentID of the AMC parameter for the selected slot.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

valueAMCslot18 1.3.6.1.4.1.1166.6.1.2.3.7.6.53
This object provides control to enable or disable AMC for the current device in the slot.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2), force(3)  

serialAMCslot18 1.3.6.1.4.1.1166.6.1.2.3.7.6.54
This object provides the serial number for the AMC slot selected.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

agentIDAMCslot18 1.3.6.1.4.1.1166.6.1.2.3.7.6.55
This object provides the agentID of the AMC parameter for the selected slot.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

autoQuickSwapCnt 1.3.6.1.4.1.1166.6.1.2.3.7.6.56
This object sets the time interval as to when the Control Module will update its memory with quick swap data. The Control Module will enable the quick swap feature for each module in the system. It will then retrieve the quick swap data from each module. The timer settings are as follows: 1=timeroff, 2=onehour, 3=oneday, 4=oneweek.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER timeroff(1), onehour(2), oneday(3), oneweek(4)  

gx2cmDiagnosticTableIndex 1.3.6.1.4.1.1166.6.1.2.3.9.8.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

ledTestValue 1.3.6.1.4.1.1166.6.1.2.3.9.8.2
This object provides the LED test pattern on/off control.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

bpTestCnt 1.3.6.1.4.1.1166.6.1.2.3.9.8.3
The value of this object control which slot the alarm poll command will be repeatedly sent to. During this operation normal polling is disabled. 0-off, 1-18 selects the slot.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

successTransSlot1 1.3.6.1.4.1.1166.6.1.2.3.9.8.4
This object provides data on the number of time writing to the selected slot passes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

successTransSlot2 1.3.6.1.4.1.1166.6.1.2.3.9.8.5
This object provides data on the number of time writing to the selected slot passes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

successTransSlot3 1.3.6.1.4.1.1166.6.1.2.3.9.8.6
This object provides data on the number of time writing to the selected slot passes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

successTransSlot4 1.3.6.1.4.1.1166.6.1.2.3.9.8.7
This object provides data on the number of time writing to the selected slot passes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

successTransSlot5 1.3.6.1.4.1.1166.6.1.2.3.9.8.8
This object provides data on the number of time writing to the selected slot passes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

successTransSlot6 1.3.6.1.4.1.1166.6.1.2.3.9.8.9
This object provides data on the number of time writing to the selected slot passes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

successTransSlot7 1.3.6.1.4.1.1166.6.1.2.3.9.8.10
This object provides data on the number of time writing to the selected slot passes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

successTransSlot8 1.3.6.1.4.1.1166.6.1.2.3.9.8.11
This object provides data on the number of time writing to the selected slot passes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

successTransSlot9 1.3.6.1.4.1.1166.6.1.2.3.9.8.12
This object provides data on the number of time writing to the selected slot passes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

successTransSlot10 1.3.6.1.4.1.1166.6.1.2.3.9.8.13
This object provides data on the number of time writing to the selected slot passes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

successTransSlot11 1.3.6.1.4.1.1166.6.1.2.3.9.8.14
This object provides data on the number of time writing to the selected slot passes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

successTransSlot12 1.3.6.1.4.1.1166.6.1.2.3.9.8.15
This object provides data on the number of time writing to the selected slot passes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

successTransSlot13 1.3.6.1.4.1.1166.6.1.2.3.9.8.16
This object provides data on the number of time writing to the selected slot passes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

successTransSlot14 1.3.6.1.4.1.1166.6.1.2.3.9.8.17
This object provides data on the number of time writing to the selected slot passes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

successTransSlot15 1.3.6.1.4.1.1166.6.1.2.3.9.8.18
This object provides data on the number of time writing to the selected slot passes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

successTransSlot16 1.3.6.1.4.1.1166.6.1.2.3.9.8.19
This object provides data on the number of time writing to the selected slot passes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

successTransSlot17 1.3.6.1.4.1.1166.6.1.2.3.9.8.20
This object provides data on the number of time writing to the selected slot passes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

successTransSlot18 1.3.6.1.4.1.1166.6.1.2.3.9.8.21
This object provides data on the number of time writing to the selected slot passes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

failureTransSlot1 1.3.6.1.4.1.1166.6.1.2.3.9.8.22
This object provides data on the number of time writing to the selected slot fails.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

failureTransSlot2 1.3.6.1.4.1.1166.6.1.2.3.9.8.23
This object provides data on the number of time writing to the selected slot fails.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

failureTransSlot3 1.3.6.1.4.1.1166.6.1.2.3.9.8.24
This object provides data on the number of time writing to the selected slot fails.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

failureTransSlot4 1.3.6.1.4.1.1166.6.1.2.3.9.8.25
This object provides data on the number of time writing to the selected slot fails.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

failureTransSlot5 1.3.6.1.4.1.1166.6.1.2.3.9.8.26
This object provides data on the number of time writing to the selected slot fails.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

failureTransSlot6 1.3.6.1.4.1.1166.6.1.2.3.9.8.27
This object provides data on the number of time writing to the selected slot fails.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

failureTransSlot7 1.3.6.1.4.1.1166.6.1.2.3.9.8.28
This object provides data on the number of time writing to the selected slot fails.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

failureTransSlot8 1.3.6.1.4.1.1166.6.1.2.3.9.8.29
This object provides data on the number of time writing to the selected slot fails.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

failureTransSlot9 1.3.6.1.4.1.1166.6.1.2.3.9.8.30
This object provides data on the number of time writing to the selected slot fails.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

failureTransSlot10 1.3.6.1.4.1.1166.6.1.2.3.9.8.31
This object provides data on the number of time writing to the selected slot fails.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

failureTransSlot11 1.3.6.1.4.1.1166.6.1.2.3.9.8.32
This object provides data on the number of time writing to the selected slot fails.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

failureTransSlot12 1.3.6.1.4.1.1166.6.1.2.3.9.8.33
This object provides data on the number of time writing to the selected slot fails.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

failureTransSlot13 1.3.6.1.4.1.1166.6.1.2.3.9.8.34
This object provides data on the number of time writing to the selected slot fails.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

failureTransSlot14 1.3.6.1.4.1.1166.6.1.2.3.9.8.35
This object provides data on the number of time writing to the selected slot fails.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

failureTransSlot15 1.3.6.1.4.1.1166.6.1.2.3.9.8.36
This object provides data on the number of time writing to the selected slot fails.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

failureTransSlot16 1.3.6.1.4.1.1166.6.1.2.3.9.8.37
This object provides data on the number of time writing to the selected slot fails.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

failureTransSlot17 1.3.6.1.4.1.1166.6.1.2.3.9.8.38
This object provides data on the number of time writing to the selected slot fails.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

failureTransSlot18 1.3.6.1.4.1.1166.6.1.2.3.9.8.39
This object provides data on the number of time writing to the selected slot fails.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

fanTestMode 1.3.6.1.4.1.1166.6.1.2.3.9.8.40
This object provides control for putting the fan in manual test mode. Writing any non-zero value will set to on
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

fanControl 1.3.6.1.4.1.1166.6.1.2.3.9.8.41
This object provides control over the fan mode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

relayTestMode 1.3.6.1.4.1.1166.6.1.2.3.9.8.42
This object provides control for putting the relay in manual test mode. Writing any non-zero value will set to on
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

relayControl 1.3.6.1.4.1.1166.6.1.2.3.9.8.43
This object provides control for putting the relay in manual test mode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER open(1), closed(2)  

slotPollMode 1.3.6.1.4.1.1166.6.1.2.3.9.8.44
This object provides control of the slotpoll test mode. When on the slotpoll operation is disabled.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

bootCount 1.3.6.1.4.1.1166.6.1.2.3.9.8.45
This object provides the value of how many times the CM went though a boot/rest process.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

objectTableData 1.3.6.1.4.1.1166.6.1.2.3.9.8.46
This object provides the OID for the start loations for the status, digital and analog tables. This data is used by the web server application.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

setSysTime 1.3.6.1.4.1.1166.6.1.2.3.9.8.47
Writing any value to this object will reset sysUpTime to zero.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

gx2cmDownloadTableIndex 1.3.6.1.4.1.1166.6.1.2.3.10.9.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

downloadValue 1.3.6.1.4.1.1166.6.1.2.3.10.9.2
This object provides the slot(s) to be downloaded. The slots to be downloaded corresponds to the following bit map. bit 0 - control module, bits 1-18 to the corresponding slot. Any combination of bit may be set. If all bits are reset this will halt the download.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

autoDownloadReset 1.3.6.1.4.1.1166.6.1.2.3.10.9.3
This object determines if the module will be reset directly after a successfull download. 0 - Deactivated, 1+ Activated
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER deactivate(1), activate(2)  

downloadFilename 1.3.6.1.4.1.1166.6.1.2.3.10.9.4
This object provides the name of the file for download
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..80)  

downloadState 1.3.6.1.4.1.1166.6.1.2.3.10.9.5
This object provides the current state of the download process.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

switchFwBank 1.3.6.1.4.1.1166.6.1.2.3.10.9.6
Writting to this object causes the firmware bank to switch and execute from that bank. The range of values that can be entered for this object is from 0 to 18. Where 0 is slot 0, and 18 is slot 18.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

cmTrapHistoryTableIndex 1.3.6.1.4.1.1166.6.1.2.3.11.10.1
This object identifies the trap issued by the network element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

netrapId 1.3.6.1.4.1.1166.6.1.2.3.11.10.2
The value of this objest is the trap ID number provided by network element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

netrapNetworkElemModelNumber 1.3.6.1.4.1.1166.6.1.2.3.11.10.3
The value of this object is the model number of the network element. Combination of Model # and Serial # is used as the unique identifier of the NE.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

netrapNetworkElemSerialNum 1.3.6.1.4.1.1166.6.1.2.3.11.10.4
The value of this object is the serial number of the network element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

netrapPerceivedSeverity 1.3.6.1.4.1.1166.6.1.2.3.11.10.5
This parameter defines five severity levels, which provide an indication of the perceived status of the managed object.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

netrapNetworkElemOperState 1.3.6.1.4.1.1166.6.1.2.3.11.10.6
The current Operational State of the Network Element which generated the trap..
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

netrapNetworkElemAlarmStatus 1.3.6.1.4.1.1166.6.1.2.3.11.10.7
The current Alarm Status of the Network Element. Alarm Status is always equal to the highest severity level of all outstanding alarms in this NE..
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

netrapNetworkElemAdminState 1.3.6.1.4.1.1166.6.1.2.3.11.10.8
The current Adminsitrative state of the network element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

netrapNetworkElemAvailStatus 1.3.6.1.4.1.1166.6.1.2.3.11.10.9
The current Operational state of the network elment
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

netrapText 1.3.6.1.4.1.1166.6.1.2.3.11.10.10
This variable contains trap text.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

netrapLastTrapTimeStamp 1.3.6.1.4.1.1166.6.1.2.3.11.10.11
This OBJECT IDENTIFIER is used to hold time when trap was generated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

netrapChangedObjectId 1.3.6.1.4.1.1166.6.1.2.3.11.10.12
This variable identifies the object that has generated the trap.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

netrapAdditionalInfoInteger1 1.3.6.1.4.1.1166.6.1.2.3.11.10.13
This 32 bit integer is used to hold specific information about the trap.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

netrapAdditionalInfoInteger2 1.3.6.1.4.1.1166.6.1.2.3.11.10.14
this 32 bit integer is used to hold specific information about the trap.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

netrapAdditionalInfoInteger3 1.3.6.1.4.1.1166.6.1.2.3.11.10.15
This 32 bit integer is used to hold specific information about the trap.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

netrapChangedValueDisplayString 1.3.6.1.4.1.1166.6.1.2.3.11.10.16
This DisplayString is used to hold specific information about the trap
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

netrapChangedValueOID 1.3.6.1.4.1.1166.6.1.2.3.11.10.17
This OBJECT IDENTIFIER is used to hold specific information about the trap
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

netrapChangedValueIpAddress 1.3.6.1.4.1.1166.6.1.2.3.11.10.18
This OBJECT IDENTIFIER is used to hold specific information about the trap.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

netrapChangedValueInteger 1.3.6.1.4.1.1166.6.1.2.3.11.10.19
this 32 bit integer is used to hold the data value that this object has been changed too.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

trapCMConfigChangeInteger 1
This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE    

trapCMConfigChangeDisplayString 2
This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE    

trapCMModuleTempAlarm 3
This trap is issued when the Module Temperature parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapCMEEPROMAlarm 4
This trap is issued when the EEPROM detectes an error. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapCMFlashAlarm 5
This trap is issued when the Flash device detects an error. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapCMHardwareAlarm 6
This trap is issued when the system hardware detectes an error. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapCMInitEEPROMAlarm 7
This trap is issued when the there is an EEPROM initializing error. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapCMBootAlarm 8
This trap is issued when the there is a boot error. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE