Nortel-MsCarrier-MscPassport-DisdnETSIMIB

File: Nortel-MsCarrier-MscPassport-DisdnETSIMIB.mib (29133 bytes)

Imported modules

RFC-1212 Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB Nortel-MsCarrier-MscPassport-StandardTextualConventionsMIB
Nortel-MsCarrier-MscPassport-TextualConventionsMIB Nortel-MsCarrier-MscPassport-DataIsdnMIB

Imported symbols

OBJECT-TYPE mscPassportMIBs DisplayString
StorageType RowStatus Unsigned32
NonReplicated Link mscDataSigChanIndex
mscDataSigChan

Defined Types

MscDataSigChanEtsiRowStatusEntry  
SEQUENCE    
  mscDataSigChanEtsiRowStatus RowStatus
  mscDataSigChanEtsiComponentName DisplayString
  mscDataSigChanEtsiStorageType StorageType
  mscDataSigChanEtsiIndex NonReplicated

MscDataSigChanEtsiL2Entry  
SEQUENCE    
  mscDataSigChanEtsiT23 Unsigned32
  mscDataSigChanEtsiT200 Unsigned32
  mscDataSigChanEtsiN200 Unsigned32
  mscDataSigChanEtsiT203 Unsigned32
  mscDataSigChanEtsiN201 Unsigned32
  mscDataSigChanEtsiCircuitSwitchedK Unsigned32

MscDataSigChanEtsiProvEntry  
SEQUENCE    
  mscDataSigChanEtsiSide INTEGER

MscDataSigChanEtsiOperEntry  
SEQUENCE    
  mscDataSigChanEtsiActiveChannels Unsigned32
  mscDataSigChanEtsiPeakActiveChannels Unsigned32
  mscDataSigChanEtsiDChanStatus INTEGER

MscDataSigChanEtsiToolsEntry  
SEQUENCE    
  mscDataSigChanEtsiTracing OCTET STRING

MscDataSigChanEtsiFramerRowStatusEntry  
SEQUENCE    
  mscDataSigChanEtsiFramerRowStatus RowStatus
  mscDataSigChanEtsiFramerComponentName DisplayString
  mscDataSigChanEtsiFramerStorageType StorageType
  mscDataSigChanEtsiFramerIndex NonReplicated

MscDataSigChanEtsiFramerProvEntry  
SEQUENCE    
  mscDataSigChanEtsiFramerInterfaceName Link

MscDataSigChanEtsiFramerStateEntry  
SEQUENCE    
  mscDataSigChanEtsiFramerAdminState INTEGER
  mscDataSigChanEtsiFramerOperationalState INTEGER
  mscDataSigChanEtsiFramerUsageState INTEGER

MscDataSigChanEtsiFramerStatsEntry  
SEQUENCE    
  mscDataSigChanEtsiFramerFrmToIf Unsigned32
  mscDataSigChanEtsiFramerFrmFromIf Unsigned32
  mscDataSigChanEtsiFramerOctetFromIf Unsigned32
  mscDataSigChanEtsiFramerAborts Unsigned32
  mscDataSigChanEtsiFramerCrcErrors Unsigned32
  mscDataSigChanEtsiFramerLrcErrors Unsigned32
  mscDataSigChanEtsiFramerNonOctetErrors Unsigned32
  mscDataSigChanEtsiFramerOverruns Unsigned32
  mscDataSigChanEtsiFramerUnderruns Unsigned32
  mscDataSigChanEtsiFramerLargeFrmErrors Unsigned32

Defined Values

disdnETSIMIB 1.3.6.1.4.1.562.36.2.2.117
OBJECT IDENTIFIER    

mscDataSigChanEtsi 1.3.6.1.4.1.562.36.2.1.120.10
OBJECT IDENTIFIER    

mscDataSigChanEtsiRowStatusTable 1.3.6.1.4.1.562.36.2.1.120.10.1
This entry controls the addition and deletion of mscDataSigChanEtsi components.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MscDataSigChanEtsiRowStatusEntry

mscDataSigChanEtsiRowStatusEntry 1.3.6.1.4.1.562.36.2.1.120.10.1.1
A single entry in the table represents a single mscDataSigChanEtsi component.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MscDataSigChanEtsiRowStatusEntry  

mscDataSigChanEtsiRowStatus 1.3.6.1.4.1.562.36.2.1.120.10.1.1.1
This variable is used as the basis for SNMP naming of mscDataSigChanEtsi components. These components can be added and deleted.
Status: mandatory Access: read-write
OBJECT-TYPE    
  RowStatus  

mscDataSigChanEtsiComponentName 1.3.6.1.4.1.562.36.2.1.120.10.1.1.2
This variable provides the component's string name for use with the ASCII Console Interface
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

mscDataSigChanEtsiStorageType 1.3.6.1.4.1.562.36.2.1.120.10.1.1.4
This variable represents the storage type value for the mscDataSigChanEtsi tables.
Status: mandatory Access: read-only
OBJECT-TYPE    
  StorageType  

mscDataSigChanEtsiIndex 1.3.6.1.4.1.562.36.2.1.120.10.1.1.10
This variable represents the index for the mscDataSigChanEtsi tables.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  NonReplicated  

mscDataSigChanEtsiL2Table 1.3.6.1.4.1.562.36.2.1.120.10.11
This group represents the provisionable Layer 2 attributes of the Q931 CCITT protocol.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MscDataSigChanEtsiL2Entry

mscDataSigChanEtsiL2Entry 1.3.6.1.4.1.562.36.2.1.120.10.11.1
An entry in the mscDataSigChanEtsiL2Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MscDataSigChanEtsiL2Entry  

mscDataSigChanEtsiT23 1.3.6.1.4.1.562.36.2.1.120.10.11.1.1
This attribute specifies the layer2 enable request timer.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 1..15  

mscDataSigChanEtsiT200 1.3.6.1.4.1.562.36.2.1.120.10.11.1.2
This attribute specifies the maximum time between a layer 2 frame and its acknowledgement
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 1..20  

mscDataSigChanEtsiN200 1.3.6.1.4.1.562.36.2.1.120.10.11.1.3
This attribute specifies the maximum number of re-transmissions of a layer2 frame.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 1..8  

mscDataSigChanEtsiT203 1.3.6.1.4.1.562.36.2.1.120.10.11.1.4
This attribute specifies the maximum time that a no layer 2 traffic situation can last. Expiry triggers a check on whether the far end is a live.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 2..40  

mscDataSigChanEtsiN201 1.3.6.1.4.1.562.36.2.1.120.10.11.1.5
This attribute specifies the maximum number of octets in an information field.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 4..260  

mscDataSigChanEtsiCircuitSwitchedK 1.3.6.1.4.1.562.36.2.1.120.10.11.1.6
This attribute specifies the maximum number of frames for B channel use.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 1..632  

mscDataSigChanEtsiProvTable 1.3.6.1.4.1.562.36.2.1.120.10.13
This group defines the general options of the d-channel signalling link.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MscDataSigChanEtsiProvEntry

mscDataSigChanEtsiProvEntry 1.3.6.1.4.1.562.36.2.1.120.10.13.1
An entry in the mscDataSigChanEtsiProvTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MscDataSigChanEtsiProvEntry  

mscDataSigChanEtsiSide 1.3.6.1.4.1.562.36.2.1.120.10.13.1.1
This attribute specifies whether the layer 2 HDLC interface is the network or user side of the connection.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER network(1), user(2)  

mscDataSigChanEtsiOperTable 1.3.6.1.4.1.562.36.2.1.120.10.15
This group provides the operational attributes for the signalling protocol.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MscDataSigChanEtsiOperEntry

mscDataSigChanEtsiOperEntry 1.3.6.1.4.1.562.36.2.1.120.10.15.1
An entry in the mscDataSigChanEtsiOperTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MscDataSigChanEtsiOperEntry  

mscDataSigChanEtsiActiveChannels 1.3.6.1.4.1.562.36.2.1.120.10.15.1.1
This attribute indicates the number of currently active channels. This includes data and voice channels.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..128  

mscDataSigChanEtsiPeakActiveChannels 1.3.6.1.4.1.562.36.2.1.120.10.15.1.4
This attribute indicates the maximum number of channels that have been active on this signalling channel during the last polling period.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..128  

mscDataSigChanEtsiDChanStatus 1.3.6.1.4.1.562.36.2.1.120.10.15.1.7
This attribute indicates the state of the D-channel. outOfService means that there is no layer 2 or layer 3 connectivity to the PBX. establishing means that the signalling channel is attempting to stage the layer 2. established means that the layer 2 is enabled. If the signalling channel stays in the established state, then it is waiting for a restart from the PBX. enabling means that the resources for processing calls are being initialized. If the signalling channel stays in the enabling state then it is waiting for a restart acknowledgement from the PBX. inService means that the resources for processing calls are available. restarting means that the resources for call processing are being rei- initialized.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER outOfService(0), establishing(1), established(2), enabling(3), inService(4), restarting(5)  

mscDataSigChanEtsiToolsTable 1.3.6.1.4.1.562.36.2.1.120.10.16
This group contains a series of operational attributes which turn on and off several kinds of tracing.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MscDataSigChanEtsiToolsEntry

mscDataSigChanEtsiToolsEntry 1.3.6.1.4.1.562.36.2.1.120.10.16.1
An entry in the mscDataSigChanEtsiToolsTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MscDataSigChanEtsiToolsEntry  

mscDataSigChanEtsiTracing 1.3.6.1.4.1.562.36.2.1.120.10.16.1.1
This attribute defines which types of tracing are active for this signalling channel. The tracing messages are sent to the debug stream. To see the messages the agentQueue attribute in Col/debug must be greater than 0 and a Telnet NMIS session must list the debug stream in in its data streams (ex. set nmis telnet session/1 dataStreams debug). Different types of tracing can be enabled simultaneously. Note that tracing consumes additional CPU resources and will slow down call processing on a heavily loaded card. If there is message block exhaustion tracing will be suspended for a period and then automatically reenabled. An alarm is generated on tracing suspension and resumption. This mechanism protects the function processor against excessive numbers of tracing messages. Types of tracing include: protocolErrors - get details of any protocol errors which are occuring. Protocol errors are also reported in summary form as alarms. q931Summary - Summary of the Q.931 messages on the signalling link, including certain call details (calling number, called number, release codes). q931Hex - Q.931 messages displayed in hex format. Useful to determine protocol compliance in case of errors reported on local or remote ends. q931Symbolic - Q.931 messages parsed to give maximum detail. Useful for understanding content of messages flowing on the link. portHex - Messages in hex format being sent and received on the link. Description of bits: protocolErrors(0) q931Summary(1) q931Hex(2) q931Symbolic(3) portHex(4)
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1)  

mscDataSigChanEtsiFramer 1.3.6.1.4.1.562.36.2.1.120.10.2
OBJECT IDENTIFIER    

mscDataSigChanEtsiFramerRowStatusTable 1.3.6.1.4.1.562.36.2.1.120.10.2.1
This entry controls the addition and deletion of mscDataSigChanEtsiFramer components.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MscDataSigChanEtsiFramerRowStatusEntry

mscDataSigChanEtsiFramerRowStatusEntry 1.3.6.1.4.1.562.36.2.1.120.10.2.1.1
A single entry in the table represents a single mscDataSigChanEtsiFramer component.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MscDataSigChanEtsiFramerRowStatusEntry  

mscDataSigChanEtsiFramerRowStatus 1.3.6.1.4.1.562.36.2.1.120.10.2.1.1.1
This variable is used as the basis for SNMP naming of mscDataSigChanEtsiFramer components. These components cannot be added nor deleted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  RowStatus  

mscDataSigChanEtsiFramerComponentName 1.3.6.1.4.1.562.36.2.1.120.10.2.1.1.2
This variable provides the component's string name for use with the ASCII Console Interface
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

mscDataSigChanEtsiFramerStorageType 1.3.6.1.4.1.562.36.2.1.120.10.2.1.1.4
This variable represents the storage type value for the mscDataSigChanEtsiFramer tables.
Status: mandatory Access: read-only
OBJECT-TYPE    
  StorageType  

mscDataSigChanEtsiFramerIndex 1.3.6.1.4.1.562.36.2.1.120.10.2.1.1.10
This variable represents the index for the mscDataSigChanEtsiFramer tables.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  NonReplicated  

mscDataSigChanEtsiFramerProvTable 1.3.6.1.4.1.562.36.2.1.120.10.2.10
This group contains the base provisioning data for the Framer component. Application or hardware interface specific provisioning data is contained in other provisionable Framer groups.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MscDataSigChanEtsiFramerProvEntry

mscDataSigChanEtsiFramerProvEntry 1.3.6.1.4.1.562.36.2.1.120.10.2.10.1
An entry in the mscDataSigChanEtsiFramerProvTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MscDataSigChanEtsiFramerProvEntry  

mscDataSigChanEtsiFramerInterfaceName 1.3.6.1.4.1.562.36.2.1.120.10.2.10.1.1
This attribute contains a hardware component name. The attribute associates the application with a specific link. This defines the module processor on which Framer's parent component (as well as Framer itself) will run.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Link  

mscDataSigChanEtsiFramerStateTable 1.3.6.1.4.1.562.36.2.1.120.10.2.12
This group contains the three OSI State attributes. The descriptions generically indicate what each state attribute implies about the component. Note that not all the values and state combinations described here are supported by every component which uses this group. For component-specific information and the valid state combinations, refer to NTP 241-7001-150, Passport Operations and Maintenance Guide.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MscDataSigChanEtsiFramerStateEntry

mscDataSigChanEtsiFramerStateEntry 1.3.6.1.4.1.562.36.2.1.120.10.2.12.1
An entry in the mscDataSigChanEtsiFramerStateTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MscDataSigChanEtsiFramerStateEntry  

mscDataSigChanEtsiFramerAdminState 1.3.6.1.4.1.562.36.2.1.120.10.2.12.1.1
This attribute indicates the OSI Administrative State of the component. The value locked indicates that the component is administratively prohibited from providing services for its users. A Lock or Lock - force command has been previously issued for this component. When the value is locked, the value of usageState must be idle. The value shuttingDown indicates that the component is administratively permitted to provide service to its existing users only. A Lock command was issued against the component and it is in the process of shutting down. The value unlocked indicates that the component is administratively permitted to provide services for its users. To enter this state, issue an Unlock command to this component.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER locked(0), unlocked(1), shuttingDown(2)  

mscDataSigChanEtsiFramerOperationalState 1.3.6.1.4.1.562.36.2.1.120.10.2.12.1.2
This attribute indicates the OSI Operational State of the component. The value enabled indicates that the component is available for operation. Note that if adminState is locked, it would still not be providing service. The value disabled indicates that the component is not available for operation. For example, something is wrong with the component itself, or with another component on which this one depends. If the value is disabled, the usageState must be idle.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

mscDataSigChanEtsiFramerUsageState 1.3.6.1.4.1.562.36.2.1.120.10.2.12.1.3
This attribute indicates the OSI Usage State of the component. The value idle indicates that the component is not currently in use. The value active indicates that the component is in use and has spare capacity to provide for additional users. The value busy indicates that the component is in use and has no spare operating capacity for additional users at this time.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER idle(0), active(1), busy(2)  

mscDataSigChanEtsiFramerStatsTable 1.3.6.1.4.1.562.36.2.1.120.10.2.13
This group contains the operational statistics data for a Framer component.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MscDataSigChanEtsiFramerStatsEntry

mscDataSigChanEtsiFramerStatsEntry 1.3.6.1.4.1.562.36.2.1.120.10.2.13.1
An entry in the mscDataSigChanEtsiFramerStatsTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MscDataSigChanEtsiFramerStatsEntry  

mscDataSigChanEtsiFramerFrmToIf 1.3.6.1.4.1.562.36.2.1.120.10.2.13.1.1
This attribute counts the number of frames transmitted to the link interface by Framer. This count wraps to zero after reaching its maximum value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

mscDataSigChanEtsiFramerFrmFromIf 1.3.6.1.4.1.562.36.2.1.120.10.2.13.1.2
This attribute counts the number of frames received from the link interface by Framer. This count wraps to zero after reaching its maximum value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

mscDataSigChanEtsiFramerOctetFromIf 1.3.6.1.4.1.562.36.2.1.120.10.2.13.1.3
The number of bytes received from the link interface by Framer.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

mscDataSigChanEtsiFramerAborts 1.3.6.1.4.1.562.36.2.1.120.10.2.13.1.4
This attribute counts the total number of aborts received. This count wraps to zero after reaching its maximum value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

mscDataSigChanEtsiFramerCrcErrors 1.3.6.1.4.1.562.36.2.1.120.10.2.13.1.5
This attribute counts the total number of frames with CRC errors. This count wraps to zero after reaching its maximum value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

mscDataSigChanEtsiFramerLrcErrors 1.3.6.1.4.1.562.36.2.1.120.10.2.13.1.6
This attribute counts the total number of frames with LRC errors. This count wraps to zero after reaching its maximum value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

mscDataSigChanEtsiFramerNonOctetErrors 1.3.6.1.4.1.562.36.2.1.120.10.2.13.1.7
This attribute counts the total number of frames that were non octet aligned. This count wraps to zero after reaching its maximum value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

mscDataSigChanEtsiFramerOverruns 1.3.6.1.4.1.562.36.2.1.120.10.2.13.1.8
This attribute counts the total number of frames received from the link for which overruns occurred. This count wraps to zero after reaching its maximum value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

mscDataSigChanEtsiFramerUnderruns 1.3.6.1.4.1.562.36.2.1.120.10.2.13.1.9
This attribute counts the total number of frames transmitted to the link for which underruns occurred. This count wraps to zero after reaching its maximum value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

mscDataSigChanEtsiFramerLargeFrmErrors 1.3.6.1.4.1.562.36.2.1.120.10.2.13.1.10
This attribute counts the total number of frames received which were too large. The frame was longer than 500 bytes. This count wraps to zero after reaching its maximum value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

disdnETSIGroup 1.3.6.1.4.1.562.36.2.2.117.1
OBJECT IDENTIFIER    

disdnETSIGroupCA 1.3.6.1.4.1.562.36.2.2.117.1.1
OBJECT IDENTIFIER    

disdnETSIGroupCA02 1.3.6.1.4.1.562.36.2.2.117.1.1.3
OBJECT IDENTIFIER    

disdnETSIGroupCA02A 1.3.6.1.4.1.562.36.2.2.117.1.1.3.2
OBJECT IDENTIFIER    

disdnETSICapabilities 1.3.6.1.4.1.562.36.2.2.117.3
OBJECT IDENTIFIER    

disdnETSICapabilitiesCA 1.3.6.1.4.1.562.36.2.2.117.3.1
OBJECT IDENTIFIER    

disdnETSICapabilitiesCA02 1.3.6.1.4.1.562.36.2.2.117.3.1.3
OBJECT IDENTIFIER    

disdnETSICapabilitiesCA02A 1.3.6.1.4.1.562.36.2.2.117.3.1.3.2
OBJECT IDENTIFIER