Nortel-Magellan-Passport-SubnetInterfaceMIB

File: Nortel-Magellan-Passport-SubnetInterfaceMIB.mib (28245 bytes)

Imported modules

RFC-1212 Nortel-Magellan-Passport-UsefulDefinitionsMIB Nortel-Magellan-Passport-StandardTextualConventionsMIB
Nortel-Magellan-Passport-TextualConventionsMIB Nortel-Magellan-Passport-ShelfMIB

Imported symbols

OBJECT-TYPE passportMIBs DisplayString
StorageType RowStatus Integer32
Unsigned32 NonReplicated DigitString
mod modIndex

Defined Types

ModVcsRowStatusEntry  
SEQUENCE    
  modVcsRowStatus RowStatus
  modVcsComponentName DisplayString
  modVcsStorageType StorageType
  modVcsIndex NonReplicated

ModVcsAccOptEntry  
SEQUENCE    
  modVcsSegmentSize INTEGER
  modVcsUnitsCounted INTEGER
  modVcsAccountingFax OCTET STRING
  modVcsGenerationMode INTEGER

ModVcsAddOptEntry  
SEQUENCE    
  modVcsDefaultNumberingPlan INTEGER
  modVcsNetworkIdType INTEGER
  modVcsX121Type INTEGER
  modVcsNetworkIdCode DigitString
  modVcsX121IntlAddresses INTEGER
  modVcsX121IntllPrefixDigit Unsigned32
  modVcsX121MinAddressLength Unsigned32
  modVcsX121MaxAddressLength Unsigned32
  modVcsX121ToE164EscapeSignificance INTEGER
  modVcsE164IntlFormatAllowed INTEGER
  modVcsE164IntlPrefixDigits DigitString
  modVcsE164NatlPrefixDigit Unsigned32
  modVcsE164LocalAddressLength Unsigned32
  modVcsE164TeleCountryCode DigitString
  modVcsE164NatlMinAddressLength Unsigned32
  modVcsE164NatlMaxAddressLength Unsigned32
  modVcsE164IntlMinAddressLength Unsigned32
  modVcsE164IntlMaxAddressLength Unsigned32
  modVcsE164LocalMinAddressLength Unsigned32
  modVcsE164LocalMaxAddressLength Unsigned32

ModVcsIntOptEntry  
SEQUENCE    
  modVcsHighPriorityPacketSizes OCTET STRING
  modVcsMaxSubnetPacketSize INTEGER
  modVcsCallSetupTimer Unsigned32
  modVcsCallRetryTimer Unsigned32
  modVcsDelaySubnetAcks INTEGER

ModVcsWinsEntry  
SEQUENCE    
  modVcsWinsPktIndex INTEGER
  modVcsWinsTptIndex Integer32
  modVcsWinsValue Unsigned32

Defined Values

subnetInterfaceMIB 1.3.6.1.4.1.562.2.4.2.45
OBJECT IDENTIFIER    

modVcs 1.3.6.1.4.1.562.2.4.1.16.2
OBJECT IDENTIFIER    

modVcsRowStatusTable 1.3.6.1.4.1.562.2.4.1.16.2.1
This entry controls the addition and deletion of modVcs components.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ModVcsRowStatusEntry

modVcsRowStatusEntry 1.3.6.1.4.1.562.2.4.1.16.2.1.1
A single entry in the table represents a single modVcs component.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ModVcsRowStatusEntry  

modVcsRowStatus 1.3.6.1.4.1.562.2.4.1.16.2.1.1.1
This variable is used as the basis for SNMP naming of modVcs components. These components can be added and deleted.
Status: mandatory Access: read-write
OBJECT-TYPE    
  RowStatus  

modVcsComponentName 1.3.6.1.4.1.562.2.4.1.16.2.1.1.2
This variable provides the component's string name for use with the ASCII Console Interface
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

modVcsStorageType 1.3.6.1.4.1.562.2.4.1.16.2.1.1.4
This variable represents the storage type value for the modVcs tables.
Status: mandatory Access: read-only
OBJECT-TYPE    
  StorageType  

modVcsIndex 1.3.6.1.4.1.562.2.4.1.16.2.1.1.10
This variable represents the index for the modVcs tables.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  NonReplicated  

modVcsAccOptTable 1.3.6.1.4.1.562.2.4.1.16.2.10
Accounting information is owned by the Vc System; it is stored in the Vc Accounting component, which itself is considered to be a component on the switch. The Accounting Component contains a bit map indicating which of the accounting facilities are to be spooled in the accounting record - for example, bit '0' if set indicates that the accounting facility with facility code H.00 should be spooled if present in the Vc for accounting purposes. The data contained in the Vc Accounting must be identical network wide even though the component can be changed and upgraded on a module by module basis.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ModVcsAccOptEntry

modVcsAccOptEntry 1.3.6.1.4.1.562.2.4.1.16.2.10.1
An entry in the modVcsAccOptTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ModVcsAccOptEntry  

modVcsSegmentSize 1.3.6.1.4.1.562.2.4.1.16.2.10.1.1
This attribute specifies the segment size for accounting of national calls. Minimum allowed segment size is 1. If data segment is sent which is less than segmentSize it is still counted as one segment.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER n1(0), n2(1), n4(2), n8(3), n16(4), n32(5), n64(6), n128(7), n256(8), n512(9), n1024(10), n2048(11), n4096(12)  

modVcsUnitsCounted 1.3.6.1.4.1.562.2.4.1.16.2.10.1.2
This attribute specifies what is counted by frame services. If set to frames, frames are counted, else segments are counted.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER segments(0), frames(1)  

modVcsAccountingFax 1.3.6.1.4.1.562.2.4.1.16.2.10.1.3
Each value corresponds to an accounting facility code, of which there are currently 10 facility codes defined with codes H.00 to H.09, and corresponding to the above 10 facilities. Each of the above facilities may or may not be present and stored in the Vc for accounting purposes, depending on the nature of the call. For example, only those Vcs where a NUI (Network User Identifier) is used for charging or identification purposes will have a NUI stored in the Vc. Description of bits: notused0(0) notused1(1) originalCalledAddressFax(2)
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1)  

modVcsGenerationMode 1.3.6.1.4.1.562.2.4.1.16.2.10.1.4
This attribute specifies part of the rules by which the network generates accounting records. If set to bothEnds, then both ends of the Vc generate accounting records. If set to singleEnd, then the charged end of the Vc generates accounting records. In single end generation mode, if the call does not clear gracefully, both ends of the Vc will generate accounting record.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER bothEnds(0), singleEnd(1)  

modVcsAddOptTable 1.3.6.1.4.1.562.2.4.1.16.2.12
The Vc AddressingOptions group describes the addressing parameters. It is currently owned by the Vc. Most of the data contained in the Vc AddressingOptions group is identical network wide even though the group can be changed and upgraded on a module by module basis.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ModVcsAddOptEntry

modVcsAddOptEntry 1.3.6.1.4.1.562.2.4.1.16.2.12.1
An entry in the modVcsAddOptTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ModVcsAddOptEntry  

modVcsDefaultNumberingPlan 1.3.6.1.4.1.562.2.4.1.16.2.12.1.3
This attribute specifies the numbering plan used which determines the address format: X.121-- the international numbering plan for public packet switched data networks or E.164-- the international numbering plan for ISDN and PSTN. The default numbering plan does not need to be consistent across all of the nodes in the network.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER x121(0), e164(1)  

modVcsNetworkIdType 1.3.6.1.4.1.562.2.4.1.16.2.12.1.4
This attribute specifies whether the network uses a DNIC or INIC. It is used by X.75 Gateways to indicate whether in network the DNIC or INIC is used in various utilities. If it is DNIC it can be DNIC or DCC type. If it is INIC it can be 4 digits only.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER dnic(0), inic(1)  

modVcsX121Type 1.3.6.1.4.1.562.2.4.1.16.2.12.1.5
This attribute specifies whether DNIC mode or DCC mode is used in X.121 address of international calls. If DCC is specified, then the first 3 digits of each DNA must be the Network ID Code. If this attribute is changed all Dnas in the network must start with this code. Numbering plan is affected by the change.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER dnic(0), dcc(1)  

modVcsNetworkIdCode 1.3.6.1.4.1.562.2.4.1.16.2.12.1.6
This attribute specifies the DNIC (Data Network ID Code) of the network or DCC code.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DigitString Size(3..4)  

modVcsX121IntlAddresses 1.3.6.1.4.1.562.2.4.1.16.2.12.1.7
This attribute indicates if any DTE is allowed to signal international addresses.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disallowed(0), allowed(1)  

modVcsX121IntllPrefixDigit 1.3.6.1.4.1.562.2.4.1.16.2.12.1.8
This attribute indicates the prefix digit to be used for X.121 international calls. When this digit is provided the call will have full international address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 0..9  

modVcsX121MinAddressLength 1.3.6.1.4.1.562.2.4.1.16.2.12.1.11
This attribute indicates minimum length of x121 address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 1..16  

modVcsX121MaxAddressLength 1.3.6.1.4.1.562.2.4.1.16.2.12.1.12
This attribute indicates maximum length of x121 address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 1..16  

modVcsX121ToE164EscapeSignificance 1.3.6.1.4.1.562.2.4.1.16.2.12.1.13
This attribute specifies whether an X.121 to E.164 escape digit has significance in selecting an X.32 (analog) or an ISDN switched path. If two values are significant (the value 0 or the value 9) then yes is set to this attribute. If the value of the originally entered escape digit is not significant in routing the call then value of no is assigned to this attribute.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(0), yes(1)  

modVcsE164IntlFormatAllowed 1.3.6.1.4.1.562.2.4.1.16.2.12.1.14
This attribute indicates whether or not to allow national format E.164 addresses. If this attribute is set to a value of Yes (=1) then national format E.164 addresses are not allowed and international format addresses only are allowed. If this attribute is set to a value of No (=0), then national format E.164 addresses are allowed. If only international format E.164 addresses are allowed, then the 'e164NatlPrefixDigit' attribute is not required, nor is the 'e164IntlPrefixDigits' required.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disallowed(0), allowed(1)  

modVcsE164IntlPrefixDigits 1.3.6.1.4.1.562.2.4.1.16.2.12.1.15
This attribute specifies the E.164 international prefix digits. If applicable, it is specified as 1 to 3 BCD digits. The 3 BCD digits are stored with the length of the international prefix in the low order nibble, nibble [0] followed by the most significant digit of the international prefix in the next low order nibble, nibble [1], etc. This attribute is not required if the corresponding attribute, 'e164IntlFormatOnly' is set to a value of Yes (=1).
Status: mandatory Access: read-write
OBJECT-TYPE    
  DigitString Size(0..3)  

modVcsE164NatlPrefixDigit 1.3.6.1.4.1.562.2.4.1.16.2.12.1.16
This attribute contains the E.164 national prefix which may be added in front of E.164 local or national call. If e164IntlFormatOnly is set to 1, this attribute is not needed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 0..9  

modVcsE164LocalAddressLength 1.3.6.1.4.1.562.2.4.1.16.2.12.1.17
This attribute indicates the length of a local E.164 DNA on this module. This attribute is not required if the corresponding attribute, e164IntlFormatOnly is set to a value of yes. This attribute does not need to be consistent across all of the nodes in the network.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 4..15  

modVcsE164TeleCountryCode 1.3.6.1.4.1.562.2.4.1.16.2.12.1.18
This attribute specifies the E.164 Telephone Country Code (TCC) for the country in which the network resides. If applicable, it is specified as 1 to 3 BCD digits. The 3 BCD digits are stored with the length of the TCC in the low order nibble, nibble [0] followed by the most significant digit of the TCC in the next low order nibble, nibble [1], etc.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DigitString Size(1..4)  

modVcsE164NatlMinAddressLength 1.3.6.1.4.1.562.2.4.1.16.2.12.1.20
This attribute indicates minimum length of e164 national address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 1..16  

modVcsE164NatlMaxAddressLength 1.3.6.1.4.1.562.2.4.1.16.2.12.1.21
This attribute indicates maximum length of e164 national address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 1..16  

modVcsE164IntlMinAddressLength 1.3.6.1.4.1.562.2.4.1.16.2.12.1.22
This attribute indicates minimum length of e164 international address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 1..16  

modVcsE164IntlMaxAddressLength 1.3.6.1.4.1.562.2.4.1.16.2.12.1.23
This attribute indicates maximum length of e164 international address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 1..16  

modVcsE164LocalMinAddressLength 1.3.6.1.4.1.562.2.4.1.16.2.12.1.24
This attribute indicates minimum length of e164 local address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 1..16  

modVcsE164LocalMaxAddressLength 1.3.6.1.4.1.562.2.4.1.16.2.12.1.25
This attribute indicates maximum length of e164 local address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 1..16  

modVcsIntOptTable 1.3.6.1.4.1.562.2.4.1.16.2.13
The Vc InterfaceOptions group defines Vc system parameters common in the network. It is owned by the Vc and is considered to be a module wide component on the switch. The data contained in the Vc InterfaceOptions group must be identical network wide even though this group can be changed and upgraded on a module by module basis.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ModVcsIntOptEntry

modVcsIntOptEntry 1.3.6.1.4.1.562.2.4.1.16.2.13.1
An entry in the modVcsIntOptTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ModVcsIntOptEntry  

modVcsHighPriorityPacketSizes 1.3.6.1.4.1.562.2.4.1.16.2.13.1.1
This attribute indicates which packet sizes are supported for high priority calls within the network. Description of bits: n16(0) n32(1) n64(2) n128(3) n256(4) n512(5) n1024(6) n2048(7) n4096(8)
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(2)  

modVcsMaxSubnetPacketSize 1.3.6.1.4.1.562.2.4.1.16.2.13.1.2
This attribute specifies the maximum subnet packet size used for the connections originating or terminating on this module. All modules in the same network should have the same maxSubnetPacketSize. If this value is not identical throughout the network, the following points need to be considered: a) When Passport and DPN switches are connected in the same network, the maxSubnetPacketSize on a DPN switch can be at most 2048 and the DPN part of the network must be configured with hardware which supports this size: - Dedicated PE386 Network link/Trunk - Minimum measured link speed of 256Kbits/sec This hardware has to be present on every potential data path between connecting end points! b) The calling end of the connection signals the maxSubnetPacketSize value to the called end. The called end then compares this value to its own provisioned value and selects the smaller value. Note that this smaller value is not signalled back to the calling end. The calling and called ends can therefore have different maxSubnetPacketSize values.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER n16(4), n32(5), n64(6), n128(7), n256(8), n512(9), n1024(10), n2048(11), n4096(12)  

modVcsCallSetupTimer 1.3.6.1.4.1.562.2.4.1.16.2.13.1.3
This attribute specifies the Vc callSetupTimer in units of 1 second ticks. This timer specifies how long the Vc will wait, after sending a subnet Call Request packet into the network, for a response from the remote end of the Vc (in the form of a subnet Raccept packet). If, after sending a subnet Call packet into the network, a response is not received within this time period, the Vc will time out, clearing the call in the assumption that the remote end is unreachable. This timer must be long enough to take into account the time required for routing the subnet Call Request through the Source Call Routing and the Destination Call Routing systems in order to be delivered to the final destination.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 5..100  

modVcsCallRetryTimer 1.3.6.1.4.1.562.2.4.1.16.2.13.1.4
This attribute specifies, for Vc implementing Direct Calls with the auto-call retry feature (including PVCs), the Vc callRetryTimer in units of 1 second ticks. This timer specifies how long the Vc will wait between unsuccessful call attempts.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 30..300  

modVcsDelaySubnetAcks 1.3.6.1.4.1.562.2.4.1.16.2.13.1.5
This attribute specifies delay acknowledgment timer mechanism. If this attribute is set to no, then the Vc will automatically return acknowledgment packets without delay. If this attribute is set to yes, then the Vc will wait for one second in an attempt to piggyback the acknowledgment packet on another credit or data packet. If the Vc cannot piggyback the acknowledgment packet within this time, then the packet is returned without piggybacking.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(0), yes(1)  

modVcsWinsTable 1.3.6.1.4.1.562.2.4.1.16.2.213
This is the windowSize corresponding to the given packet size and throughput class. All Vcs using the windowSize matrix support large Vc windows on both ends of the Vc, and support the signalling of the chosen Vc window size from the destination (called) end to the source (calling) end. This is the only matrix supported. The windowSize should be configured in the same way network wide, though it can be upgraded on a module by module basis. Vcs using the windowSize matrix will run properly if the matrices on different nodes differ since the Vc window is selected by the destination (called) side of the Vc.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ModVcsWinsEntry

modVcsWinsEntry 1.3.6.1.4.1.562.2.4.1.16.2.213.1
An entry in the modVcsWinsTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ModVcsWinsEntry  

modVcsWinsPktIndex 1.3.6.1.4.1.562.2.4.1.16.2.213.1.1
This variable represents the next to last index for the modVcsWinsTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER n16(0), n32(1), n64(2), n128(3), n256(4), n512(5), n1024(6), n2048(7), n4096(8), n8192(9), n32768(10), n65535(11)  

modVcsWinsTptIndex 1.3.6.1.4.1.562.2.4.1.16.2.213.1.2
This variable represents the final index for the modVcsWinsTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Integer32 0..15  

modVcsWinsValue 1.3.6.1.4.1.562.2.4.1.16.2.213.1.3
This variable represents an individual value for the modVcsWinsTable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 1..63  

subnetInterfaceGroup 1.3.6.1.4.1.562.2.4.2.45.1
OBJECT IDENTIFIER    

subnetInterfaceGroupBE 1.3.6.1.4.1.562.2.4.2.45.1.5
OBJECT IDENTIFIER    

subnetInterfaceGroupBE00 1.3.6.1.4.1.562.2.4.2.45.1.5.1
OBJECT IDENTIFIER    

subnetInterfaceGroupBE00A 1.3.6.1.4.1.562.2.4.2.45.1.5.1.2
OBJECT IDENTIFIER    

subnetInterfaceCapabilities 1.3.6.1.4.1.562.2.4.2.45.3
OBJECT IDENTIFIER    

subnetInterfaceCapabilitiesBE 1.3.6.1.4.1.562.2.4.2.45.3.5
OBJECT IDENTIFIER    

subnetInterfaceCapabilitiesBE00 1.3.6.1.4.1.562.2.4.2.45.3.5.1
OBJECT IDENTIFIER    

subnetInterfaceCapabilitiesBE00A 1.3.6.1.4.1.562.2.4.2.45.3.5.1.2
OBJECT IDENTIFIER