Nortel-Magellan-Passport-FrameRelayUniTraceMIB

File: Nortel-Magellan-Passport-FrameRelayUniTraceMIB.mib (13664 bytes)

Imported modules

RFC-1212 Nortel-Magellan-Passport-UsefulDefinitionsMIB Nortel-Magellan-Passport-StandardTextualConventionsMIB
Nortel-Magellan-Passport-TextualConventionsMIB Nortel-Magellan-Passport-FrameRelayUniMIB

Imported symbols

OBJECT-TYPE passportMIBs RowPointer
DisplayString StorageType RowStatus
Unsigned32 AsciiString NonReplicated
frUniIndex frUni

Defined Types

FrUniTraceRowStatusEntry  
SEQUENCE    
  frUniTraceRowStatus RowStatus
  frUniTraceComponentName DisplayString
  frUniTraceStorageType StorageType
  frUniTraceIndex NonReplicated

FrUniTraceOperationalEntry  
SEQUENCE    
  frUniTraceReceiverName AsciiString
  frUniTraceDuration Unsigned32
  frUniTraceQueueLimit Unsigned32
  frUniTraceSession RowPointer

FrUniTraceFilterRowStatusEntry  
SEQUENCE    
  frUniTraceFilterRowStatus RowStatus
  frUniTraceFilterComponentName DisplayString
  frUniTraceFilterStorageType StorageType
  frUniTraceFilterIndex NonReplicated

FrUniTraceFilterOperationalEntry  
SEQUENCE    
  frUniTraceFilterTraceType OCTET STRING
  frUniTraceFilterTracedDlci Unsigned32
  frUniTraceFilterDirection OCTET STRING
  frUniTraceFilterTracedLength Unsigned32

Defined Values

frameRelayUniTraceMIB 1.1.562.2.4.2.105
OBJECT IDENTIFIER    

frUniTrace 1.1.562.2.4.1.71.7
OBJECT IDENTIFIER    

frUniTraceRowStatusTable 1.1.562.2.4.1.71.7.1
This entry controls the addition and deletion of frUniTrace components.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FrUniTraceRowStatusEntry

frUniTraceRowStatusEntry 1.1.562.2.4.1.71.7.1.1
A single entry in the table represents a single frUniTrace component.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FrUniTraceRowStatusEntry  

frUniTraceRowStatus 1.1.562.2.4.1.71.7.1.1.1
This variable is used as the basis for SNMP naming of frUniTrace components. These components can be added and deleted.
Status: mandatory Access: read-write
OBJECT-TYPE    
  RowStatus  

frUniTraceComponentName 1.1.562.2.4.1.71.7.1.1.2
This variable provides the component's string name for use with the ASCII Console Interface
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

frUniTraceStorageType 1.1.562.2.4.1.71.7.1.1.4
This variable represents the storage type value for the frUniTrace tables.
Status: mandatory Access: read-only
OBJECT-TYPE    
  StorageType  

frUniTraceIndex 1.1.562.2.4.1.71.7.1.1.10
This variable represents the index for the frUniTrace tables.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  NonReplicated  

frUniTraceOperationalTable 1.1.562.2.4.1.71.7.10
This group provides the operational attributes for the Trace component.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FrUniTraceOperationalEntry

frUniTraceOperationalEntry 1.1.562.2.4.1.71.7.10.1
An entry in the frUniTraceOperationalTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FrUniTraceOperationalEntry  

frUniTraceReceiverName 1.1.562.2.4.1.71.7.10.1.2
This attribute should be set to the name of the desired trace receiver before starting a trace session. All available trace receivers are listed under the Trace Rcvr/ component. This attribute cannot be set while a trace is active.
Status: mandatory Access: read-write
OBJECT-TYPE    
  AsciiString Size(0..8)  

frUniTraceDuration 1.1.562.2.4.1.71.7.10.1.3
This attribute specifies the duration, in minutes, of a trace session. A value of 0 indicates unlimited duration in which case a trace session remains active until a stop command is issued. The default duration is 60 minutes. This attribute cannot be set while a trace is active.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 0..9999  

frUniTraceQueueLimit 1.1.562.2.4.1.71.7.10.1.4
This attribute specifies the total number of bytes of traced data which may be queued for transmission to the trace receiver. When this limit is exceeded, incoming traced frames are discarded. This attribute can be set while a trace is active and takes effect immediately.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 1..100  

frUniTraceSession 1.1.562.2.4.1.71.7.10.1.5
This attribute is set automatically. It identifies the Trace Session component which is forwarding the trace data. This attribute is empty unless a trace is active.
Status: mandatory Access: read-only
OBJECT-TYPE    
  RowPointer  

frUniTraceFilter 1.1.562.2.4.1.71.7.2
OBJECT IDENTIFIER    

frUniTraceFilterRowStatusTable 1.1.562.2.4.1.71.7.2.1
This entry controls the addition and deletion of frUniTraceFilter components.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FrUniTraceFilterRowStatusEntry

frUniTraceFilterRowStatusEntry 1.1.562.2.4.1.71.7.2.1.1
A single entry in the table represents a single frUniTraceFilter component.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FrUniTraceFilterRowStatusEntry  

frUniTraceFilterRowStatus 1.1.562.2.4.1.71.7.2.1.1.1
This variable is used as the basis for SNMP naming of frUniTraceFilter components. These components cannot be added nor deleted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  RowStatus  

frUniTraceFilterComponentName 1.1.562.2.4.1.71.7.2.1.1.2
This variable provides the component's string name for use with the ASCII Console Interface
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

frUniTraceFilterStorageType 1.1.562.2.4.1.71.7.2.1.1.4
This variable represents the storage type value for the frUniTraceFilter tables.
Status: mandatory Access: read-only
OBJECT-TYPE    
  StorageType  

frUniTraceFilterIndex 1.1.562.2.4.1.71.7.2.1.1.10
This variable represents the index for the frUniTraceFilter tables.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  NonReplicated  

frUniTraceFilterOperationalTable 1.1.562.2.4.1.71.7.2.10
This group provides the operational attributes for the Frame Relay Trace Filter component.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FrUniTraceFilterOperationalEntry

frUniTraceFilterOperationalEntry 1.1.562.2.4.1.71.7.2.10.1
An entry in the frUniTraceFilterOperationalTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FrUniTraceFilterOperationalEntry  

frUniTraceFilterTraceType 1.1.562.2.4.1.71.7.2.10.1.1
This attribute specifies the level of filtering required for this trace session. A value of lmi indicates that Lmi frames are traced. A value of dlci indicates that frames from the Dlci specified by the tracedDlci attribute are traced. A value of badFrames indicates that bad received frames (overruns, CRC errors, aborts) are traced. The default is to trace all frames. This attribute can be set while a trace is active and takes effect immediately. Description of bits: lmi(0) dlci(1) badFrames(2)
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1)  

frUniTraceFilterTracedDlci 1.1.562.2.4.1.71.7.2.10.1.2
This attribute specifies a particular Dlci to trace. A value of zero specifies that all Dlcis are to be traced. This attribute can be set while a trace is active and takes effect immediately.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 0..1007  

frUniTraceFilterDirection 1.1.562.2.4.1.71.7.2.10.1.3
This attribute specifies the direction of the data to be traced as viewed by the service. The values can be egress, and/or ingress. An egress value indicates frames outbound from the service. An ingress value indicates frames inbound to the service. This attribute can be set while a trace is active and takes effect immediately. Description of bits: egress(0) ingress(1)
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1)  

frUniTraceFilterTracedLength 1.1.562.2.4.1.71.7.2.10.1.4
This attribute specifies the maximum number of bytes to trace per frame starting from the byte following the frame flag. If the frame length is longer than the value specified by this attribute, then the traced frame is truncated. This attribute can be set while a trace is active and takes effect immediately.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 1..2000  

frameRelayUniTraceGroup 1.1.562.2.4.2.105.1
OBJECT IDENTIFIER    

frameRelayUniTraceGroupBD 1.1.562.2.4.2.105.1.4
OBJECT IDENTIFIER    

frameRelayUniTraceGroupBD01 1.1.562.2.4.2.105.1.4.2
OBJECT IDENTIFIER    

frameRelayUniTraceGroupBD01A 1.1.562.2.4.2.105.1.4.2.2
OBJECT IDENTIFIER    

frameRelayUniTraceCapabilities 1.1.562.2.4.2.105.3
OBJECT IDENTIFIER    

frameRelayUniTraceCapabilitiesBD 1.1.562.2.4.2.105.3.4
OBJECT IDENTIFIER    

frameRelayUniTraceCapabilitiesBD01 1.1.562.2.4.2.105.3.4.2
OBJECT IDENTIFIER    

frameRelayUniTraceCapabilitiesBD01A 1.1.562.2.4.2.105.3.4.2.2
OBJECT IDENTIFIER