Nortel-Magellan-Passport-FrameRelayNniTraceMIB

File: Nortel-Magellan-Passport-FrameRelayNniTraceMIB.mib (13664 bytes)

Imported modules

RFC-1212 Nortel-Magellan-Passport-UsefulDefinitionsMIB Nortel-Magellan-Passport-StandardTextualConventionsMIB
Nortel-Magellan-Passport-TextualConventionsMIB Nortel-Magellan-Passport-FrameRelayNniMIB

Imported symbols

OBJECT-TYPE passportMIBs RowPointer
DisplayString StorageType RowStatus
Unsigned32 AsciiString NonReplicated
frNniIndex frNni

Defined Types

FrNniTraceRowStatusEntry  
SEQUENCE    
  frNniTraceRowStatus RowStatus
  frNniTraceComponentName DisplayString
  frNniTraceStorageType StorageType
  frNniTraceIndex NonReplicated

FrNniTraceOperationalEntry  
SEQUENCE    
  frNniTraceReceiverName AsciiString
  frNniTraceDuration Unsigned32
  frNniTraceQueueLimit Unsigned32
  frNniTraceSession RowPointer

FrNniTraceFilterRowStatusEntry  
SEQUENCE    
  frNniTraceFilterRowStatus RowStatus
  frNniTraceFilterComponentName DisplayString
  frNniTraceFilterStorageType StorageType
  frNniTraceFilterIndex NonReplicated

FrNniTraceFilterOperationalEntry  
SEQUENCE    
  frNniTraceFilterTraceType OCTET STRING
  frNniTraceFilterTracedDlci Unsigned32
  frNniTraceFilterDirection OCTET STRING
  frNniTraceFilterTracedLength Unsigned32

Defined Values

frameRelayNniTraceMIB 1.3.6.1.4.1.562.2.4.2.106
OBJECT IDENTIFIER    

frNniTrace 1.3.6.1.4.1.562.2.4.1.70.7
OBJECT IDENTIFIER    

frNniTraceRowStatusTable 1.3.6.1.4.1.562.2.4.1.70.7.1
This entry controls the addition and deletion of frNniTrace components.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FrNniTraceRowStatusEntry

frNniTraceRowStatusEntry 1.3.6.1.4.1.562.2.4.1.70.7.1.1
A single entry in the table represents a single frNniTrace component.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FrNniTraceRowStatusEntry  

frNniTraceRowStatus 1.3.6.1.4.1.562.2.4.1.70.7.1.1.1
This variable is used as the basis for SNMP naming of frNniTrace components. These components can be added and deleted.
Status: mandatory Access: read-write
OBJECT-TYPE    
  RowStatus  

frNniTraceComponentName 1.3.6.1.4.1.562.2.4.1.70.7.1.1.2
This variable provides the component's string name for use with the ASCII Console Interface
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

frNniTraceStorageType 1.3.6.1.4.1.562.2.4.1.70.7.1.1.4
This variable represents the storage type value for the frNniTrace tables.
Status: mandatory Access: read-only
OBJECT-TYPE    
  StorageType  

frNniTraceIndex 1.3.6.1.4.1.562.2.4.1.70.7.1.1.10
This variable represents the index for the frNniTrace tables.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  NonReplicated  

frNniTraceOperationalTable 1.3.6.1.4.1.562.2.4.1.70.7.10
This group provides the operational attributes for the Trace component.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FrNniTraceOperationalEntry

frNniTraceOperationalEntry 1.3.6.1.4.1.562.2.4.1.70.7.10.1
An entry in the frNniTraceOperationalTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FrNniTraceOperationalEntry  

frNniTraceReceiverName 1.3.6.1.4.1.562.2.4.1.70.7.10.1.2
This attribute should be set to the name of the desired trace receiver before starting a trace session. All available trace receivers are listed under the Trace Rcvr/ component. This attribute cannot be set while a trace is active.
Status: mandatory Access: read-write
OBJECT-TYPE    
  AsciiString Size(0..8)  

frNniTraceDuration 1.3.6.1.4.1.562.2.4.1.70.7.10.1.3
This attribute specifies the duration, in minutes, of a trace session. A value of 0 indicates unlimited duration in which case a trace session remains active until a stop command is issued. The default duration is 60 minutes. This attribute cannot be set while a trace is active.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 0..9999  

frNniTraceQueueLimit 1.3.6.1.4.1.562.2.4.1.70.7.10.1.4
This attribute specifies the total number of bytes of traced data which may be queued for transmission to the trace receiver. When this limit is exceeded, incoming traced frames are discarded. This attribute can be set while a trace is active and takes effect immediately.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 1..100  

frNniTraceSession 1.3.6.1.4.1.562.2.4.1.70.7.10.1.5
This attribute is set automatically. It identifies the Trace Session component which is forwarding the trace data. This attribute is empty unless a trace is active.
Status: mandatory Access: read-only
OBJECT-TYPE    
  RowPointer  

frNniTraceFilter 1.3.6.1.4.1.562.2.4.1.70.7.2
OBJECT IDENTIFIER    

frNniTraceFilterRowStatusTable 1.3.6.1.4.1.562.2.4.1.70.7.2.1
This entry controls the addition and deletion of frNniTraceFilter components.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FrNniTraceFilterRowStatusEntry

frNniTraceFilterRowStatusEntry 1.3.6.1.4.1.562.2.4.1.70.7.2.1.1
A single entry in the table represents a single frNniTraceFilter component.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FrNniTraceFilterRowStatusEntry  

frNniTraceFilterRowStatus 1.3.6.1.4.1.562.2.4.1.70.7.2.1.1.1
This variable is used as the basis for SNMP naming of frNniTraceFilter components. These components cannot be added nor deleted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  RowStatus  

frNniTraceFilterComponentName 1.3.6.1.4.1.562.2.4.1.70.7.2.1.1.2
This variable provides the component's string name for use with the ASCII Console Interface
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

frNniTraceFilterStorageType 1.3.6.1.4.1.562.2.4.1.70.7.2.1.1.4
This variable represents the storage type value for the frNniTraceFilter tables.
Status: mandatory Access: read-only
OBJECT-TYPE    
  StorageType  

frNniTraceFilterIndex 1.3.6.1.4.1.562.2.4.1.70.7.2.1.1.10
This variable represents the index for the frNniTraceFilter tables.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  NonReplicated  

frNniTraceFilterOperationalTable 1.3.6.1.4.1.562.2.4.1.70.7.2.10
This group provides the operational attributes for the Frame Relay Trace Filter component.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FrNniTraceFilterOperationalEntry

frNniTraceFilterOperationalEntry 1.3.6.1.4.1.562.2.4.1.70.7.2.10.1
An entry in the frNniTraceFilterOperationalTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FrNniTraceFilterOperationalEntry  

frNniTraceFilterTraceType 1.3.6.1.4.1.562.2.4.1.70.7.2.10.1.1
This attribute specifies the level of filtering required for this trace session. A value of lmi indicates that Lmi frames are traced. A value of dlci indicates that frames from the Dlci specified by the tracedDlci attribute are traced. A value of badFrames indicates that bad received frames (overruns, CRC errors, aborts) are traced. The default is to trace all frames. This attribute can be set while a trace is active and takes effect immediately. Description of bits: lmi(0) dlci(1) badFrames(2)
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1)  

frNniTraceFilterTracedDlci 1.3.6.1.4.1.562.2.4.1.70.7.2.10.1.2
This attribute specifies a particular Dlci to trace. A value of zero specifies that all Dlcis are to be traced. This attribute can be set while a trace is active and takes effect immediately.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 0..1007  

frNniTraceFilterDirection 1.3.6.1.4.1.562.2.4.1.70.7.2.10.1.3
This attribute specifies the direction of the data to be traced as viewed by the service. The values can be egress, and/or ingress. An egress value indicates frames outbound from the service. An ingress value indicates frames inbound to the service. This attribute can be set while a trace is active and takes effect immediately. Description of bits: egress(0) ingress(1)
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1)  

frNniTraceFilterTracedLength 1.3.6.1.4.1.562.2.4.1.70.7.2.10.1.4
This attribute specifies the maximum number of bytes to trace per frame starting from the byte following the frame flag. If the frame length is longer than the value specified by this attribute, then the traced frame is truncated. This attribute can be set while a trace is active and takes effect immediately.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 1..2000  

frameRelayNniTraceGroup 1.3.6.1.4.1.562.2.4.2.106.1
OBJECT IDENTIFIER    

frameRelayNniTraceGroupBD 1.3.6.1.4.1.562.2.4.2.106.1.4
OBJECT IDENTIFIER    

frameRelayNniTraceGroupBD01 1.3.6.1.4.1.562.2.4.2.106.1.4.2
OBJECT IDENTIFIER    

frameRelayNniTraceGroupBD01A 1.3.6.1.4.1.562.2.4.2.106.1.4.2.2
OBJECT IDENTIFIER    

frameRelayNniTraceCapabilities 1.3.6.1.4.1.562.2.4.2.106.3
OBJECT IDENTIFIER    

frameRelayNniTraceCapabilitiesBD 1.3.6.1.4.1.562.2.4.2.106.3.4
OBJECT IDENTIFIER    

frameRelayNniTraceCapabilitiesBD01 1.3.6.1.4.1.562.2.4.2.106.3.4.2
OBJECT IDENTIFIER    

frameRelayNniTraceCapabilitiesBD01A 1.3.6.1.4.1.562.2.4.2.106.3.4.2.2
OBJECT IDENTIFIER