Nortel-Magellan-Passport-DisdnNI2MIB

File: Nortel-Magellan-Passport-DisdnNI2MIB.mib (27957 bytes)

Imported modules

RFC-1212 Nortel-Magellan-Passport-UsefulDefinitionsMIB Nortel-Magellan-Passport-StandardTextualConventionsMIB
Nortel-Magellan-Passport-TextualConventionsMIB Nortel-Magellan-Passport-DataIsdnMIB

Imported symbols

OBJECT-TYPE passportMIBs DisplayString
StorageType RowStatus Unsigned32
NonReplicated Link dataSigChanIndex
dataSigChan

Defined Types

DataSigChanNi2RowStatusEntry  
SEQUENCE    
  dataSigChanNi2RowStatus RowStatus
  dataSigChanNi2ComponentName DisplayString
  dataSigChanNi2StorageType StorageType
  dataSigChanNi2Index NonReplicated

DataSigChanNi2L2Entry  
SEQUENCE    
  dataSigChanNi2T23 Unsigned32
  dataSigChanNi2T200 Unsigned32
  dataSigChanNi2N200 Unsigned32
  dataSigChanNi2T203 Unsigned32
  dataSigChanNi2N201 Unsigned32
  dataSigChanNi2CircuitSwitchedK Unsigned32

DataSigChanNi2ProvEntry  
SEQUENCE    
  dataSigChanNi2Side INTEGER

DataSigChanNi2OperEntry  
SEQUENCE    
  dataSigChanNi2ActiveChannels Unsigned32
  dataSigChanNi2PeakActiveChannels Unsigned32
  dataSigChanNi2DChanStatus INTEGER

DataSigChanNi2ToolsEntry  
SEQUENCE    
  dataSigChanNi2Tracing OCTET STRING

DataSigChanNi2FramerRowStatusEntry  
SEQUENCE    
  dataSigChanNi2FramerRowStatus RowStatus
  dataSigChanNi2FramerComponentName DisplayString
  dataSigChanNi2FramerStorageType StorageType
  dataSigChanNi2FramerIndex NonReplicated

DataSigChanNi2FramerProvEntry  
SEQUENCE    
  dataSigChanNi2FramerInterfaceName Link

DataSigChanNi2FramerStateEntry  
SEQUENCE    
  dataSigChanNi2FramerAdminState INTEGER
  dataSigChanNi2FramerOperationalState INTEGER
  dataSigChanNi2FramerUsageState INTEGER

DataSigChanNi2FramerStatsEntry  
SEQUENCE    
  dataSigChanNi2FramerFrmToIf Unsigned32
  dataSigChanNi2FramerFrmFromIf Unsigned32
  dataSigChanNi2FramerOctetFromIf Unsigned32
  dataSigChanNi2FramerAborts Unsigned32
  dataSigChanNi2FramerCrcErrors Unsigned32
  dataSigChanNi2FramerLrcErrors Unsigned32
  dataSigChanNi2FramerNonOctetErrors Unsigned32
  dataSigChanNi2FramerOverruns Unsigned32
  dataSigChanNi2FramerUnderruns Unsigned32
  dataSigChanNi2FramerLargeFrmErrors Unsigned32

Defined Values

disdnNI2MIB 1.3.6.1.4.1.562.2.4.2.126
OBJECT IDENTIFIER    

dataSigChanNi2 1.3.6.1.4.1.562.2.4.1.120.12
OBJECT IDENTIFIER    

dataSigChanNi2RowStatusTable 1.3.6.1.4.1.562.2.4.1.120.12.1
This entry controls the addition and deletion of dataSigChanNi2 components.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DataSigChanNi2RowStatusEntry

dataSigChanNi2RowStatusEntry 1.3.6.1.4.1.562.2.4.1.120.12.1.1
A single entry in the table represents a single dataSigChanNi2 component.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DataSigChanNi2RowStatusEntry  

dataSigChanNi2RowStatus 1.3.6.1.4.1.562.2.4.1.120.12.1.1.1
This variable is used as the basis for SNMP naming of dataSigChanNi2 components. These components can be added and deleted.
Status: mandatory Access: read-write
OBJECT-TYPE    
  RowStatus  

dataSigChanNi2ComponentName 1.3.6.1.4.1.562.2.4.1.120.12.1.1.2
This variable provides the component's string name for use with the ASCII Console Interface
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

dataSigChanNi2StorageType 1.3.6.1.4.1.562.2.4.1.120.12.1.1.4
This variable represents the storage type value for the dataSigChanNi2 tables.
Status: mandatory Access: read-only
OBJECT-TYPE    
  StorageType  

dataSigChanNi2Index 1.3.6.1.4.1.562.2.4.1.120.12.1.1.10
This variable represents the index for the dataSigChanNi2 tables.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  NonReplicated  

dataSigChanNi2L2Table 1.3.6.1.4.1.562.2.4.1.120.12.11
This group represents the provisionable Layer 2 attributes of the Q931 CCITT protocol.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DataSigChanNi2L2Entry

dataSigChanNi2L2Entry 1.3.6.1.4.1.562.2.4.1.120.12.11.1
An entry in the dataSigChanNi2L2Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DataSigChanNi2L2Entry  

dataSigChanNi2T23 1.3.6.1.4.1.562.2.4.1.120.12.11.1.1
This attribute specifies the layer2 enable request timer.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 1..15  

dataSigChanNi2T200 1.3.6.1.4.1.562.2.4.1.120.12.11.1.2
This attribute specifies the maximum time between a layer 2 frame and its acknowledgement
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 1..20  

dataSigChanNi2N200 1.3.6.1.4.1.562.2.4.1.120.12.11.1.3
This attribute specifies the maximum number of re-transmissions of a layer2 frame.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 1..8  

dataSigChanNi2T203 1.3.6.1.4.1.562.2.4.1.120.12.11.1.4
This attribute specifies the maximum time that a no layer 2 traffic situation can last. Expiry triggers a check on whether the far end is a live.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 2..40  

dataSigChanNi2N201 1.3.6.1.4.1.562.2.4.1.120.12.11.1.5
This attribute specifies the maximum number of octets in an information field.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 4..260  

dataSigChanNi2CircuitSwitchedK 1.3.6.1.4.1.562.2.4.1.120.12.11.1.6
This attribute specifies the maximum number of frames for B channel use.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 1..632  

dataSigChanNi2ProvTable 1.3.6.1.4.1.562.2.4.1.120.12.13
This group defines the general options of the d-channel signalling link.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DataSigChanNi2ProvEntry

dataSigChanNi2ProvEntry 1.3.6.1.4.1.562.2.4.1.120.12.13.1
An entry in the dataSigChanNi2ProvTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DataSigChanNi2ProvEntry  

dataSigChanNi2Side 1.3.6.1.4.1.562.2.4.1.120.12.13.1.1
This attribute specifies whether the layer 2 HDLC interface is the network or user side of the connection.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER network(1), user(2)  

dataSigChanNi2OperTable 1.3.6.1.4.1.562.2.4.1.120.12.15
This group provides the operational attributes for the signalling protocol.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DataSigChanNi2OperEntry

dataSigChanNi2OperEntry 1.3.6.1.4.1.562.2.4.1.120.12.15.1
An entry in the dataSigChanNi2OperTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DataSigChanNi2OperEntry  

dataSigChanNi2ActiveChannels 1.3.6.1.4.1.562.2.4.1.120.12.15.1.1
This attribute indicates the number of currently active channels. This includes data and voice channels.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..128  

dataSigChanNi2PeakActiveChannels 1.3.6.1.4.1.562.2.4.1.120.12.15.1.4
This attribute indicates the maximum number of channels that have been active on this signalling channel during the last polling period.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..128  

dataSigChanNi2DChanStatus 1.3.6.1.4.1.562.2.4.1.120.12.15.1.7
This attribute indicates the state of the D-channel. outOfService means that there is no layer 2 or layer 3 connectivity to the PBX. establishing means that the signalling channel is attempting to stage the layer 2. established means that the layer 2 is enabled. If the signalling channel stays in the established state, then it is waiting for a restart from the PBX. enabling means that the resources for processing calls are being initialized. If the signalling channel stays in the enabling state then it is waiting for a restart acknowledgement from the PBX. inService means that the resources for processing calls are available. restarting means that the resources for call processing are being rei- initialized.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER outOfService(0), establishing(1), established(2), enabling(3), inService(4), restarting(5)  

dataSigChanNi2ToolsTable 1.3.6.1.4.1.562.2.4.1.120.12.16
This group contains a series of operational attributes which turn on and off several kinds of tracing.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DataSigChanNi2ToolsEntry

dataSigChanNi2ToolsEntry 1.3.6.1.4.1.562.2.4.1.120.12.16.1
An entry in the dataSigChanNi2ToolsTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DataSigChanNi2ToolsEntry  

dataSigChanNi2Tracing 1.3.6.1.4.1.562.2.4.1.120.12.16.1.1
This attribute defines which types of tracing are active for this signalling channel. The tracing messages are sent to the debug stream. To see the messages the agentQueue attribute in Col/debug must be greater than 0 and a Telnet NMIS session must list the debug stream in in its data streams (ex. set nmis telnet session/1 dataStreams debug). Different types of tracing can be enabled simultaneously. Note that tracing consumes additional CPU resources and will slow down call processing on a heavily loaded card. If there is message block exhaustion tracing will be suspended for a period and then automatically reenabled. An alarm is generated on tracing suspension and resumption. This mechanism protects the function processor against excessive numbers of tracing messages. Types of tracing include: protocolErrors - get details of any protocol errors which are occuring. Protocol errors are also reported in summary form as alarms. q931Summary - Summary of the Q.931 messages on the signalling link, including certain call details (calling number, called number, release codes). q931Hex - Q.931 messages displayed in hex format. Useful to determine protocol compliance in case of errors reported on local or remote ends. q931Symbolic - Q.931 messages parsed to give maximum detail. Useful for understanding content of messages flowing on the link. portHex - Messages in hex format being sent and received on the link. Description of bits: protocolErrors(0) q931Summary(1) q931Hex(2) q931Symbolic(3) portHex(4)
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1)  

dataSigChanNi2Framer 1.3.6.1.4.1.562.2.4.1.120.12.2
OBJECT IDENTIFIER    

dataSigChanNi2FramerRowStatusTable 1.3.6.1.4.1.562.2.4.1.120.12.2.1
This entry controls the addition and deletion of dataSigChanNi2Framer components.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DataSigChanNi2FramerRowStatusEntry

dataSigChanNi2FramerRowStatusEntry 1.3.6.1.4.1.562.2.4.1.120.12.2.1.1
A single entry in the table represents a single dataSigChanNi2Framer component.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DataSigChanNi2FramerRowStatusEntry  

dataSigChanNi2FramerRowStatus 1.3.6.1.4.1.562.2.4.1.120.12.2.1.1.1
This variable is used as the basis for SNMP naming of dataSigChanNi2Framer components. These components cannot be added nor deleted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  RowStatus  

dataSigChanNi2FramerComponentName 1.3.6.1.4.1.562.2.4.1.120.12.2.1.1.2
This variable provides the component's string name for use with the ASCII Console Interface
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

dataSigChanNi2FramerStorageType 1.3.6.1.4.1.562.2.4.1.120.12.2.1.1.4
This variable represents the storage type value for the dataSigChanNi2Framer tables.
Status: mandatory Access: read-only
OBJECT-TYPE    
  StorageType  

dataSigChanNi2FramerIndex 1.3.6.1.4.1.562.2.4.1.120.12.2.1.1.10
This variable represents the index for the dataSigChanNi2Framer tables.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  NonReplicated  

dataSigChanNi2FramerProvTable 1.3.6.1.4.1.562.2.4.1.120.12.2.10
This group contains the base provisioning data for the Framer component. Application or hardware interface specific provisioning data is contained in other provisionable Framer groups.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DataSigChanNi2FramerProvEntry

dataSigChanNi2FramerProvEntry 1.3.6.1.4.1.562.2.4.1.120.12.2.10.1
An entry in the dataSigChanNi2FramerProvTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DataSigChanNi2FramerProvEntry  

dataSigChanNi2FramerInterfaceName 1.3.6.1.4.1.562.2.4.1.120.12.2.10.1.1
This attribute contains a hardware component name. The attribute associates the application with a specific link. This defines the module processor on which Framer's parent component (as well as Framer itself) will run.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Link  

dataSigChanNi2FramerStateTable 1.3.6.1.4.1.562.2.4.1.120.12.2.12
This group contains the three OSI State attributes. The descriptions generically indicate what each state attribute implies about the component. Note that not all the values and state combinations described here are supported by every component which uses this group. For component-specific information and the valid state combinations, refer to NTP 241-7001-150, Passport Operations and Maintenance Guide.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DataSigChanNi2FramerStateEntry

dataSigChanNi2FramerStateEntry 1.3.6.1.4.1.562.2.4.1.120.12.2.12.1
An entry in the dataSigChanNi2FramerStateTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DataSigChanNi2FramerStateEntry  

dataSigChanNi2FramerAdminState 1.3.6.1.4.1.562.2.4.1.120.12.2.12.1.1
This attribute indicates the OSI Administrative State of the component. The value locked indicates that the component is administratively prohibited from providing services for its users. A Lock or Lock - force command has been previously issued for this component. When the value is locked, the value of usageState must be idle. The value shuttingDown indicates that the component is administratively permitted to provide service to its existing users only. A Lock command was issued against the component and it is in the process of shutting down. The value unlocked indicates that the component is administratively permitted to provide services for its users. To enter this state, issue an Unlock command to this component.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER locked(0), unlocked(1), shuttingDown(2)  

dataSigChanNi2FramerOperationalState 1.3.6.1.4.1.562.2.4.1.120.12.2.12.1.2
This attribute indicates the OSI Operational State of the component. The value enabled indicates that the component is available for operation. Note that if adminState is locked, it would still not be providing service. The value disabled indicates that the component is not available for operation. For example, something is wrong with the component itself, or with another component on which this one depends. If the value is disabled, the usageState must be idle.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

dataSigChanNi2FramerUsageState 1.3.6.1.4.1.562.2.4.1.120.12.2.12.1.3
This attribute indicates the OSI Usage State of the component. The value idle indicates that the component is not currently in use. The value active indicates that the component is in use and has spare capacity to provide for additional users. The value busy indicates that the component is in use and has no spare operating capacity for additional users at this time.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER idle(0), active(1), busy(2)  

dataSigChanNi2FramerStatsTable 1.3.6.1.4.1.562.2.4.1.120.12.2.13
This group contains the operational statistics data for a Framer component.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DataSigChanNi2FramerStatsEntry

dataSigChanNi2FramerStatsEntry 1.3.6.1.4.1.562.2.4.1.120.12.2.13.1
An entry in the dataSigChanNi2FramerStatsTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DataSigChanNi2FramerStatsEntry  

dataSigChanNi2FramerFrmToIf 1.3.6.1.4.1.562.2.4.1.120.12.2.13.1.1
This attribute counts the number of frames transmitted to the link interface by Framer. This count wraps to zero after reaching its maximum value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

dataSigChanNi2FramerFrmFromIf 1.3.6.1.4.1.562.2.4.1.120.12.2.13.1.2
This attribute counts the number of frames received from the link interface by Framer. This count wraps to zero after reaching its maximum value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

dataSigChanNi2FramerOctetFromIf 1.3.6.1.4.1.562.2.4.1.120.12.2.13.1.3
The number of bytes received from the link interface by Framer.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

dataSigChanNi2FramerAborts 1.3.6.1.4.1.562.2.4.1.120.12.2.13.1.4
This attribute counts the total number of aborts received. This count wraps to zero after reaching its maximum value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

dataSigChanNi2FramerCrcErrors 1.3.6.1.4.1.562.2.4.1.120.12.2.13.1.5
This attribute counts the total number of frames with CRC errors. This count wraps to zero after reaching its maximum value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

dataSigChanNi2FramerLrcErrors 1.3.6.1.4.1.562.2.4.1.120.12.2.13.1.6
This attribute counts the total number of frames with LRC errors. This count wraps to zero after reaching its maximum value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

dataSigChanNi2FramerNonOctetErrors 1.3.6.1.4.1.562.2.4.1.120.12.2.13.1.7
This attribute counts the total number of frames that were non octet aligned. This count wraps to zero after reaching its maximum value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

dataSigChanNi2FramerOverruns 1.3.6.1.4.1.562.2.4.1.120.12.2.13.1.8
This attribute counts the total number of frames received from the link for which overruns occurred. This count wraps to zero after reaching its maximum value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

dataSigChanNi2FramerUnderruns 1.3.6.1.4.1.562.2.4.1.120.12.2.13.1.9
This attribute counts the total number of frames transmitted to the link for which underruns occurred. This count wraps to zero after reaching its maximum value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

dataSigChanNi2FramerLargeFrmErrors 1.3.6.1.4.1.562.2.4.1.120.12.2.13.1.10
This attribute counts the total number of frames received which were too large. The frame was longer than 500 bytes. This count wraps to zero after reaching its maximum value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

disdnNI2Group 1.3.6.1.4.1.562.2.4.2.126.1
OBJECT IDENTIFIER    

disdnNI2GroupBE 1.3.6.1.4.1.562.2.4.2.126.1.5
OBJECT IDENTIFIER    

disdnNI2GroupBE00 1.3.6.1.4.1.562.2.4.2.126.1.5.1
OBJECT IDENTIFIER    

disdnNI2GroupBE00A 1.3.6.1.4.1.562.2.4.2.126.1.5.1.2
OBJECT IDENTIFIER    

disdnNI2Capabilities 1.3.6.1.4.1.562.2.4.2.126.3
OBJECT IDENTIFIER    

disdnNI2CapabilitiesBE 1.3.6.1.4.1.562.2.4.2.126.3.5
OBJECT IDENTIFIER    

disdnNI2CapabilitiesBE00 1.3.6.1.4.1.562.2.4.2.126.3.5.1
OBJECT IDENTIFIER    

disdnNI2CapabilitiesBE00A 1.3.6.1.4.1.562.2.4.2.126.3.5.1.2
OBJECT IDENTIFIER