Nortel-Magellan-Passport-DisdnJapanInsMIB

File: Nortel-Magellan-Passport-DisdnJapanInsMIB.mib (28072 bytes)

Imported modules

RFC-1212 Nortel-Magellan-Passport-UsefulDefinitionsMIB Nortel-Magellan-Passport-StandardTextualConventionsMIB
Nortel-Magellan-Passport-TextualConventionsMIB Nortel-Magellan-Passport-DataIsdnMIB

Imported symbols

OBJECT-TYPE passportMIBs DisplayString
StorageType RowStatus Unsigned32
NonReplicated Link dataSigChanIndex
dataSigChan

Defined Types

DataSigChanInsRowStatusEntry  
SEQUENCE    
  dataSigChanInsRowStatus RowStatus
  dataSigChanInsComponentName DisplayString
  dataSigChanInsStorageType StorageType
  dataSigChanInsIndex NonReplicated

DataSigChanInsL2Entry  
SEQUENCE    
  dataSigChanInsT23 Unsigned32
  dataSigChanInsT200 Unsigned32
  dataSigChanInsN200 Unsigned32
  dataSigChanInsT203 Unsigned32
  dataSigChanInsN201 Unsigned32
  dataSigChanInsCircuitSwitchedK Unsigned32

DataSigChanInsProvEntry  
SEQUENCE    
  dataSigChanInsSide INTEGER

DataSigChanInsOperEntry  
SEQUENCE    
  dataSigChanInsActiveChannels Unsigned32
  dataSigChanInsPeakActiveChannels Unsigned32
  dataSigChanInsDChanStatus INTEGER

DataSigChanInsToolsEntry  
SEQUENCE    
  dataSigChanInsTracing OCTET STRING

DataSigChanInsFramerRowStatusEntry  
SEQUENCE    
  dataSigChanInsFramerRowStatus RowStatus
  dataSigChanInsFramerComponentName DisplayString
  dataSigChanInsFramerStorageType StorageType
  dataSigChanInsFramerIndex NonReplicated

DataSigChanInsFramerProvEntry  
SEQUENCE    
  dataSigChanInsFramerInterfaceName Link

DataSigChanInsFramerStateEntry  
SEQUENCE    
  dataSigChanInsFramerAdminState INTEGER
  dataSigChanInsFramerOperationalState INTEGER
  dataSigChanInsFramerUsageState INTEGER

DataSigChanInsFramerStatsEntry  
SEQUENCE    
  dataSigChanInsFramerFrmToIf Unsigned32
  dataSigChanInsFramerFrmFromIf Unsigned32
  dataSigChanInsFramerOctetFromIf Unsigned32
  dataSigChanInsFramerAborts Unsigned32
  dataSigChanInsFramerCrcErrors Unsigned32
  dataSigChanInsFramerLrcErrors Unsigned32
  dataSigChanInsFramerNonOctetErrors Unsigned32
  dataSigChanInsFramerOverruns Unsigned32
  dataSigChanInsFramerUnderruns Unsigned32
  dataSigChanInsFramerLargeFrmErrors Unsigned32

Defined Values

disdnJapanInsMIB 1.3.6.1.4.1.562.2.4.2.118
OBJECT IDENTIFIER    

dataSigChanIns 1.3.6.1.4.1.562.2.4.1.120.11
OBJECT IDENTIFIER    

dataSigChanInsRowStatusTable 1.3.6.1.4.1.562.2.4.1.120.11.1
This entry controls the addition and deletion of dataSigChanIns components.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DataSigChanInsRowStatusEntry

dataSigChanInsRowStatusEntry 1.3.6.1.4.1.562.2.4.1.120.11.1.1
A single entry in the table represents a single dataSigChanIns component.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DataSigChanInsRowStatusEntry  

dataSigChanInsRowStatus 1.3.6.1.4.1.562.2.4.1.120.11.1.1.1
This variable is used as the basis for SNMP naming of dataSigChanIns components. These components can be added and deleted.
Status: mandatory Access: read-write
OBJECT-TYPE    
  RowStatus  

dataSigChanInsComponentName 1.3.6.1.4.1.562.2.4.1.120.11.1.1.2
This variable provides the component's string name for use with the ASCII Console Interface
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

dataSigChanInsStorageType 1.3.6.1.4.1.562.2.4.1.120.11.1.1.4
This variable represents the storage type value for the dataSigChanIns tables.
Status: mandatory Access: read-only
OBJECT-TYPE    
  StorageType  

dataSigChanInsIndex 1.3.6.1.4.1.562.2.4.1.120.11.1.1.10
This variable represents the index for the dataSigChanIns tables.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  NonReplicated  

dataSigChanInsL2Table 1.3.6.1.4.1.562.2.4.1.120.11.11
This group represents the provisionable Layer 2 attributes of the Q931 CCITT protocol.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DataSigChanInsL2Entry

dataSigChanInsL2Entry 1.3.6.1.4.1.562.2.4.1.120.11.11.1
An entry in the dataSigChanInsL2Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DataSigChanInsL2Entry  

dataSigChanInsT23 1.3.6.1.4.1.562.2.4.1.120.11.11.1.1
This attribute specifies the layer2 enable request timer.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 1..15  

dataSigChanInsT200 1.3.6.1.4.1.562.2.4.1.120.11.11.1.2
This attribute specifies the maximum time between a layer 2 frame and its acknowledgement
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 1..20  

dataSigChanInsN200 1.3.6.1.4.1.562.2.4.1.120.11.11.1.3
This attribute specifies the maximum number of re-transmissions of a layer2 frame.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 1..8  

dataSigChanInsT203 1.3.6.1.4.1.562.2.4.1.120.11.11.1.4
This attribute specifies the maximum time that a no layer 2 traffic situation can last. Expiry triggers a check on whether the far end is a live.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 2..40  

dataSigChanInsN201 1.3.6.1.4.1.562.2.4.1.120.11.11.1.5
This attribute specifies the maximum number of octets in an information field.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 4..260  

dataSigChanInsCircuitSwitchedK 1.3.6.1.4.1.562.2.4.1.120.11.11.1.6
This attribute specifies the maximum number of frames for B channel use.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 1..632  

dataSigChanInsProvTable 1.3.6.1.4.1.562.2.4.1.120.11.13
This group defines the general options of the d-channel signalling link.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DataSigChanInsProvEntry

dataSigChanInsProvEntry 1.3.6.1.4.1.562.2.4.1.120.11.13.1
An entry in the dataSigChanInsProvTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DataSigChanInsProvEntry  

dataSigChanInsSide 1.3.6.1.4.1.562.2.4.1.120.11.13.1.1
This attribute specifies whether the layer 2 HDLC interface is the network or user side of the connection.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER network(1), user(2)  

dataSigChanInsOperTable 1.3.6.1.4.1.562.2.4.1.120.11.15
This group provides the operational attributes for the signalling protocol.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DataSigChanInsOperEntry

dataSigChanInsOperEntry 1.3.6.1.4.1.562.2.4.1.120.11.15.1
An entry in the dataSigChanInsOperTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DataSigChanInsOperEntry  

dataSigChanInsActiveChannels 1.3.6.1.4.1.562.2.4.1.120.11.15.1.1
This attribute indicates the number of currently active channels. This includes data and voice channels.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..128  

dataSigChanInsPeakActiveChannels 1.3.6.1.4.1.562.2.4.1.120.11.15.1.4
This attribute indicates the maximum number of channels that have been active on this signalling channel during the last polling period.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..128  

dataSigChanInsDChanStatus 1.3.6.1.4.1.562.2.4.1.120.11.15.1.7
This attribute indicates the state of the D-channel. outOfService means that there is no layer 2 or layer 3 connectivity to the PBX. establishing means that the signalling channel is attempting to stage the layer 2. established means that the layer 2 is enabled. If the signalling channel stays in the established state, then it is waiting for a restart from the PBX. enabling means that the resources for processing calls are being initialized. If the signalling channel stays in the enabling state then it is waiting for a restart acknowledgement from the PBX. inService means that the resources for processing calls are available. restarting means that the resources for call processing are being rei- initialized.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER outOfService(0), establishing(1), established(2), enabling(3), inService(4), restarting(5)  

dataSigChanInsToolsTable 1.3.6.1.4.1.562.2.4.1.120.11.16
This group contains a series of operational attributes which turn on and off several kinds of tracing.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DataSigChanInsToolsEntry

dataSigChanInsToolsEntry 1.3.6.1.4.1.562.2.4.1.120.11.16.1
An entry in the dataSigChanInsToolsTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DataSigChanInsToolsEntry  

dataSigChanInsTracing 1.3.6.1.4.1.562.2.4.1.120.11.16.1.1
This attribute defines which types of tracing are active for this signalling channel. The tracing messages are sent to the debug stream. To see the messages the agentQueue attribute in Col/debug must be greater than 0 and a Telnet NMIS session must list the debug stream in in its data streams (ex. set nmis telnet session/1 dataStreams debug). Different types of tracing can be enabled simultaneously. Note that tracing consumes additional CPU resources and will slow down call processing on a heavily loaded card. If there is message block exhaustion tracing will be suspended for a period and then automatically reenabled. An alarm is generated on tracing suspension and resumption. This mechanism protects the function processor against excessive numbers of tracing messages. Types of tracing include: protocolErrors - get details of any protocol errors which are occuring. Protocol errors are also reported in summary form as alarms. q931Summary - Summary of the Q.931 messages on the signalling link, including certain call details (calling number, called number, release codes). q931Hex - Q.931 messages displayed in hex format. Useful to determine protocol compliance in case of errors reported on local or remote ends. q931Symbolic - Q.931 messages parsed to give maximum detail. Useful for understanding content of messages flowing on the link. portHex - Messages in hex format being sent and received on the link. Description of bits: protocolErrors(0) q931Summary(1) q931Hex(2) q931Symbolic(3) portHex(4)
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1)  

dataSigChanInsFramer 1.3.6.1.4.1.562.2.4.1.120.11.2
OBJECT IDENTIFIER    

dataSigChanInsFramerRowStatusTable 1.3.6.1.4.1.562.2.4.1.120.11.2.1
This entry controls the addition and deletion of dataSigChanInsFramer components.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DataSigChanInsFramerRowStatusEntry

dataSigChanInsFramerRowStatusEntry 1.3.6.1.4.1.562.2.4.1.120.11.2.1.1
A single entry in the table represents a single dataSigChanInsFramer component.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DataSigChanInsFramerRowStatusEntry  

dataSigChanInsFramerRowStatus 1.3.6.1.4.1.562.2.4.1.120.11.2.1.1.1
This variable is used as the basis for SNMP naming of dataSigChanInsFramer components. These components cannot be added nor deleted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  RowStatus  

dataSigChanInsFramerComponentName 1.3.6.1.4.1.562.2.4.1.120.11.2.1.1.2
This variable provides the component's string name for use with the ASCII Console Interface
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

dataSigChanInsFramerStorageType 1.3.6.1.4.1.562.2.4.1.120.11.2.1.1.4
This variable represents the storage type value for the dataSigChanInsFramer tables.
Status: mandatory Access: read-only
OBJECT-TYPE    
  StorageType  

dataSigChanInsFramerIndex 1.3.6.1.4.1.562.2.4.1.120.11.2.1.1.10
This variable represents the index for the dataSigChanInsFramer tables.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  NonReplicated  

dataSigChanInsFramerProvTable 1.3.6.1.4.1.562.2.4.1.120.11.2.10
This group contains the base provisioning data for the Framer component. Application or hardware interface specific provisioning data is contained in other provisionable Framer groups.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DataSigChanInsFramerProvEntry

dataSigChanInsFramerProvEntry 1.3.6.1.4.1.562.2.4.1.120.11.2.10.1
An entry in the dataSigChanInsFramerProvTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DataSigChanInsFramerProvEntry  

dataSigChanInsFramerInterfaceName 1.3.6.1.4.1.562.2.4.1.120.11.2.10.1.1
This attribute contains a hardware component name. The attribute associates the application with a specific link. This defines the module processor on which Framer's parent component (as well as Framer itself) will run.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Link  

dataSigChanInsFramerStateTable 1.3.6.1.4.1.562.2.4.1.120.11.2.12
This group contains the three OSI State attributes. The descriptions generically indicate what each state attribute implies about the component. Note that not all the values and state combinations described here are supported by every component which uses this group. For component-specific information and the valid state combinations, refer to NTP 241-7001-150, Passport Operations and Maintenance Guide.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DataSigChanInsFramerStateEntry

dataSigChanInsFramerStateEntry 1.3.6.1.4.1.562.2.4.1.120.11.2.12.1
An entry in the dataSigChanInsFramerStateTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DataSigChanInsFramerStateEntry  

dataSigChanInsFramerAdminState 1.3.6.1.4.1.562.2.4.1.120.11.2.12.1.1
This attribute indicates the OSI Administrative State of the component. The value locked indicates that the component is administratively prohibited from providing services for its users. A Lock or Lock - force command has been previously issued for this component. When the value is locked, the value of usageState must be idle. The value shuttingDown indicates that the component is administratively permitted to provide service to its existing users only. A Lock command was issued against the component and it is in the process of shutting down. The value unlocked indicates that the component is administratively permitted to provide services for its users. To enter this state, issue an Unlock command to this component.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER locked(0), unlocked(1), shuttingDown(2)  

dataSigChanInsFramerOperationalState 1.3.6.1.4.1.562.2.4.1.120.11.2.12.1.2
This attribute indicates the OSI Operational State of the component. The value enabled indicates that the component is available for operation. Note that if adminState is locked, it would still not be providing service. The value disabled indicates that the component is not available for operation. For example, something is wrong with the component itself, or with another component on which this one depends. If the value is disabled, the usageState must be idle.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

dataSigChanInsFramerUsageState 1.3.6.1.4.1.562.2.4.1.120.11.2.12.1.3
This attribute indicates the OSI Usage State of the component. The value idle indicates that the component is not currently in use. The value active indicates that the component is in use and has spare capacity to provide for additional users. The value busy indicates that the component is in use and has no spare operating capacity for additional users at this time.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER idle(0), active(1), busy(2)  

dataSigChanInsFramerStatsTable 1.3.6.1.4.1.562.2.4.1.120.11.2.13
This group contains the operational statistics data for a Framer component.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DataSigChanInsFramerStatsEntry

dataSigChanInsFramerStatsEntry 1.3.6.1.4.1.562.2.4.1.120.11.2.13.1
An entry in the dataSigChanInsFramerStatsTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DataSigChanInsFramerStatsEntry  

dataSigChanInsFramerFrmToIf 1.3.6.1.4.1.562.2.4.1.120.11.2.13.1.1
This attribute counts the number of frames transmitted to the link interface by Framer. This count wraps to zero after reaching its maximum value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

dataSigChanInsFramerFrmFromIf 1.3.6.1.4.1.562.2.4.1.120.11.2.13.1.2
This attribute counts the number of frames received from the link interface by Framer. This count wraps to zero after reaching its maximum value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

dataSigChanInsFramerOctetFromIf 1.3.6.1.4.1.562.2.4.1.120.11.2.13.1.3
The number of bytes received from the link interface by Framer.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

dataSigChanInsFramerAborts 1.3.6.1.4.1.562.2.4.1.120.11.2.13.1.4
This attribute counts the total number of aborts received. This count wraps to zero after reaching its maximum value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

dataSigChanInsFramerCrcErrors 1.3.6.1.4.1.562.2.4.1.120.11.2.13.1.5
This attribute counts the total number of frames with CRC errors. This count wraps to zero after reaching its maximum value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

dataSigChanInsFramerLrcErrors 1.3.6.1.4.1.562.2.4.1.120.11.2.13.1.6
This attribute counts the total number of frames with LRC errors. This count wraps to zero after reaching its maximum value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

dataSigChanInsFramerNonOctetErrors 1.3.6.1.4.1.562.2.4.1.120.11.2.13.1.7
This attribute counts the total number of frames that were non octet aligned. This count wraps to zero after reaching its maximum value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

dataSigChanInsFramerOverruns 1.3.6.1.4.1.562.2.4.1.120.11.2.13.1.8
This attribute counts the total number of frames received from the link for which overruns occurred. This count wraps to zero after reaching its maximum value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

dataSigChanInsFramerUnderruns 1.3.6.1.4.1.562.2.4.1.120.11.2.13.1.9
This attribute counts the total number of frames transmitted to the link for which underruns occurred. This count wraps to zero after reaching its maximum value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

dataSigChanInsFramerLargeFrmErrors 1.3.6.1.4.1.562.2.4.1.120.11.2.13.1.10
This attribute counts the total number of frames received which were too large. The frame was longer than 500 bytes. This count wraps to zero after reaching its maximum value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

disdnJapanInsGroup 1.3.6.1.4.1.562.2.4.2.118.1
OBJECT IDENTIFIER    

disdnJapanInsGroupBE 1.3.6.1.4.1.562.2.4.2.118.1.5
OBJECT IDENTIFIER    

disdnJapanInsGroupBE00 1.3.6.1.4.1.562.2.4.2.118.1.5.1
OBJECT IDENTIFIER    

disdnJapanInsGroupBE00A 1.3.6.1.4.1.562.2.4.2.118.1.5.1.2
OBJECT IDENTIFIER    

disdnJapanInsCapabilities 1.3.6.1.4.1.562.2.4.2.118.3
OBJECT IDENTIFIER    

disdnJapanInsCapabilitiesBE 1.3.6.1.4.1.562.2.4.2.118.3.5
OBJECT IDENTIFIER    

disdnJapanInsCapabilitiesBE00 1.3.6.1.4.1.562.2.4.2.118.3.5.1
OBJECT IDENTIFIER    

disdnJapanInsCapabilitiesBE00A 1.3.6.1.4.1.562.2.4.2.118.3.5.1.2
OBJECT IDENTIFIER