Nortel-Magellan-Passport-DisdnETSIMIB

File: Nortel-Magellan-Passport-DisdnETSIMIB.mib (28198 bytes)

Imported modules

RFC-1212 Nortel-Magellan-Passport-UsefulDefinitionsMIB Nortel-Magellan-Passport-StandardTextualConventionsMIB
Nortel-Magellan-Passport-TextualConventionsMIB Nortel-Magellan-Passport-DataIsdnMIB

Imported symbols

OBJECT-TYPE passportMIBs DisplayString
StorageType RowStatus Unsigned32
NonReplicated Link dataSigChanIndex
dataSigChan

Defined Types

DataSigChanEtsiRowStatusEntry  
SEQUENCE    
  dataSigChanEtsiRowStatus RowStatus
  dataSigChanEtsiComponentName DisplayString
  dataSigChanEtsiStorageType StorageType
  dataSigChanEtsiIndex NonReplicated

DataSigChanEtsiL2Entry  
SEQUENCE    
  dataSigChanEtsiT23 Unsigned32
  dataSigChanEtsiT200 Unsigned32
  dataSigChanEtsiN200 Unsigned32
  dataSigChanEtsiT203 Unsigned32
  dataSigChanEtsiN201 Unsigned32
  dataSigChanEtsiCircuitSwitchedK Unsigned32

DataSigChanEtsiProvEntry  
SEQUENCE    
  dataSigChanEtsiSide INTEGER

DataSigChanEtsiOperEntry  
SEQUENCE    
  dataSigChanEtsiActiveChannels Unsigned32
  dataSigChanEtsiPeakActiveChannels Unsigned32
  dataSigChanEtsiDChanStatus INTEGER

DataSigChanEtsiToolsEntry  
SEQUENCE    
  dataSigChanEtsiTracing OCTET STRING

DataSigChanEtsiFramerRowStatusEntry  
SEQUENCE    
  dataSigChanEtsiFramerRowStatus RowStatus
  dataSigChanEtsiFramerComponentName DisplayString
  dataSigChanEtsiFramerStorageType StorageType
  dataSigChanEtsiFramerIndex NonReplicated

DataSigChanEtsiFramerProvEntry  
SEQUENCE    
  dataSigChanEtsiFramerInterfaceName Link

DataSigChanEtsiFramerStateEntry  
SEQUENCE    
  dataSigChanEtsiFramerAdminState INTEGER
  dataSigChanEtsiFramerOperationalState INTEGER
  dataSigChanEtsiFramerUsageState INTEGER

DataSigChanEtsiFramerStatsEntry  
SEQUENCE    
  dataSigChanEtsiFramerFrmToIf Unsigned32
  dataSigChanEtsiFramerFrmFromIf Unsigned32
  dataSigChanEtsiFramerOctetFromIf Unsigned32
  dataSigChanEtsiFramerAborts Unsigned32
  dataSigChanEtsiFramerCrcErrors Unsigned32
  dataSigChanEtsiFramerLrcErrors Unsigned32
  dataSigChanEtsiFramerNonOctetErrors Unsigned32
  dataSigChanEtsiFramerOverruns Unsigned32
  dataSigChanEtsiFramerUnderruns Unsigned32
  dataSigChanEtsiFramerLargeFrmErrors Unsigned32

Defined Values

disdnETSIMIB 1.3.6.1.4.1.562.2.4.2.117
OBJECT IDENTIFIER    

dataSigChanEtsi 1.3.6.1.4.1.562.2.4.1.120.10
OBJECT IDENTIFIER    

dataSigChanEtsiRowStatusTable 1.3.6.1.4.1.562.2.4.1.120.10.1
This entry controls the addition and deletion of dataSigChanEtsi components.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DataSigChanEtsiRowStatusEntry

dataSigChanEtsiRowStatusEntry 1.3.6.1.4.1.562.2.4.1.120.10.1.1
A single entry in the table represents a single dataSigChanEtsi component.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DataSigChanEtsiRowStatusEntry  

dataSigChanEtsiRowStatus 1.3.6.1.4.1.562.2.4.1.120.10.1.1.1
This variable is used as the basis for SNMP naming of dataSigChanEtsi components. These components can be added and deleted.
Status: mandatory Access: read-write
OBJECT-TYPE    
  RowStatus  

dataSigChanEtsiComponentName 1.3.6.1.4.1.562.2.4.1.120.10.1.1.2
This variable provides the component's string name for use with the ASCII Console Interface
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

dataSigChanEtsiStorageType 1.3.6.1.4.1.562.2.4.1.120.10.1.1.4
This variable represents the storage type value for the dataSigChanEtsi tables.
Status: mandatory Access: read-only
OBJECT-TYPE    
  StorageType  

dataSigChanEtsiIndex 1.3.6.1.4.1.562.2.4.1.120.10.1.1.10
This variable represents the index for the dataSigChanEtsi tables.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  NonReplicated  

dataSigChanEtsiL2Table 1.3.6.1.4.1.562.2.4.1.120.10.11
This group represents the provisionable Layer 2 attributes of the Q931 CCITT protocol.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DataSigChanEtsiL2Entry

dataSigChanEtsiL2Entry 1.3.6.1.4.1.562.2.4.1.120.10.11.1
An entry in the dataSigChanEtsiL2Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DataSigChanEtsiL2Entry  

dataSigChanEtsiT23 1.3.6.1.4.1.562.2.4.1.120.10.11.1.1
This attribute specifies the layer2 enable request timer.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 1..15  

dataSigChanEtsiT200 1.3.6.1.4.1.562.2.4.1.120.10.11.1.2
This attribute specifies the maximum time between a layer 2 frame and its acknowledgement
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 1..20  

dataSigChanEtsiN200 1.3.6.1.4.1.562.2.4.1.120.10.11.1.3
This attribute specifies the maximum number of re-transmissions of a layer2 frame.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 1..8  

dataSigChanEtsiT203 1.3.6.1.4.1.562.2.4.1.120.10.11.1.4
This attribute specifies the maximum time that a no layer 2 traffic situation can last. Expiry triggers a check on whether the far end is a live.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 2..40  

dataSigChanEtsiN201 1.3.6.1.4.1.562.2.4.1.120.10.11.1.5
This attribute specifies the maximum number of octets in an information field.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 4..260  

dataSigChanEtsiCircuitSwitchedK 1.3.6.1.4.1.562.2.4.1.120.10.11.1.6
This attribute specifies the maximum number of frames for B channel use.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 1..632  

dataSigChanEtsiProvTable 1.3.6.1.4.1.562.2.4.1.120.10.13
This group defines the general options of the d-channel signalling link.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DataSigChanEtsiProvEntry

dataSigChanEtsiProvEntry 1.3.6.1.4.1.562.2.4.1.120.10.13.1
An entry in the dataSigChanEtsiProvTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DataSigChanEtsiProvEntry  

dataSigChanEtsiSide 1.3.6.1.4.1.562.2.4.1.120.10.13.1.1
This attribute specifies whether the layer 2 HDLC interface is the network or user side of the connection.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER network(1), user(2)  

dataSigChanEtsiOperTable 1.3.6.1.4.1.562.2.4.1.120.10.15
This group provides the operational attributes for the signalling protocol.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DataSigChanEtsiOperEntry

dataSigChanEtsiOperEntry 1.3.6.1.4.1.562.2.4.1.120.10.15.1
An entry in the dataSigChanEtsiOperTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DataSigChanEtsiOperEntry  

dataSigChanEtsiActiveChannels 1.3.6.1.4.1.562.2.4.1.120.10.15.1.1
This attribute indicates the number of currently active channels. This includes data and voice channels.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..128  

dataSigChanEtsiPeakActiveChannels 1.3.6.1.4.1.562.2.4.1.120.10.15.1.4
This attribute indicates the maximum number of channels that have been active on this signalling channel during the last polling period.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..128  

dataSigChanEtsiDChanStatus 1.3.6.1.4.1.562.2.4.1.120.10.15.1.7
This attribute indicates the state of the D-channel. outOfService means that there is no layer 2 or layer 3 connectivity to the PBX. establishing means that the signalling channel is attempting to stage the layer 2. established means that the layer 2 is enabled. If the signalling channel stays in the established state, then it is waiting for a restart from the PBX. enabling means that the resources for processing calls are being initialized. If the signalling channel stays in the enabling state then it is waiting for a restart acknowledgement from the PBX. inService means that the resources for processing calls are available. restarting means that the resources for call processing are being rei- initialized.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER outOfService(0), establishing(1), established(2), enabling(3), inService(4), restarting(5)  

dataSigChanEtsiToolsTable 1.3.6.1.4.1.562.2.4.1.120.10.16
This group contains a series of operational attributes which turn on and off several kinds of tracing.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DataSigChanEtsiToolsEntry

dataSigChanEtsiToolsEntry 1.3.6.1.4.1.562.2.4.1.120.10.16.1
An entry in the dataSigChanEtsiToolsTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DataSigChanEtsiToolsEntry  

dataSigChanEtsiTracing 1.3.6.1.4.1.562.2.4.1.120.10.16.1.1
This attribute defines which types of tracing are active for this signalling channel. The tracing messages are sent to the debug stream. To see the messages the agentQueue attribute in Col/debug must be greater than 0 and a Telnet NMIS session must list the debug stream in in its data streams (ex. set nmis telnet session/1 dataStreams debug). Different types of tracing can be enabled simultaneously. Note that tracing consumes additional CPU resources and will slow down call processing on a heavily loaded card. If there is message block exhaustion tracing will be suspended for a period and then automatically reenabled. An alarm is generated on tracing suspension and resumption. This mechanism protects the function processor against excessive numbers of tracing messages. Types of tracing include: protocolErrors - get details of any protocol errors which are occuring. Protocol errors are also reported in summary form as alarms. q931Summary - Summary of the Q.931 messages on the signalling link, including certain call details (calling number, called number, release codes). q931Hex - Q.931 messages displayed in hex format. Useful to determine protocol compliance in case of errors reported on local or remote ends. q931Symbolic - Q.931 messages parsed to give maximum detail. Useful for understanding content of messages flowing on the link. portHex - Messages in hex format being sent and received on the link. Description of bits: protocolErrors(0) q931Summary(1) q931Hex(2) q931Symbolic(3) portHex(4)
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1)  

dataSigChanEtsiFramer 1.3.6.1.4.1.562.2.4.1.120.10.2
OBJECT IDENTIFIER    

dataSigChanEtsiFramerRowStatusTable 1.3.6.1.4.1.562.2.4.1.120.10.2.1
This entry controls the addition and deletion of dataSigChanEtsiFramer components.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DataSigChanEtsiFramerRowStatusEntry

dataSigChanEtsiFramerRowStatusEntry 1.3.6.1.4.1.562.2.4.1.120.10.2.1.1
A single entry in the table represents a single dataSigChanEtsiFramer component.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DataSigChanEtsiFramerRowStatusEntry  

dataSigChanEtsiFramerRowStatus 1.3.6.1.4.1.562.2.4.1.120.10.2.1.1.1
This variable is used as the basis for SNMP naming of dataSigChanEtsiFramer components. These components cannot be added nor deleted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  RowStatus  

dataSigChanEtsiFramerComponentName 1.3.6.1.4.1.562.2.4.1.120.10.2.1.1.2
This variable provides the component's string name for use with the ASCII Console Interface
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

dataSigChanEtsiFramerStorageType 1.3.6.1.4.1.562.2.4.1.120.10.2.1.1.4
This variable represents the storage type value for the dataSigChanEtsiFramer tables.
Status: mandatory Access: read-only
OBJECT-TYPE    
  StorageType  

dataSigChanEtsiFramerIndex 1.3.6.1.4.1.562.2.4.1.120.10.2.1.1.10
This variable represents the index for the dataSigChanEtsiFramer tables.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  NonReplicated  

dataSigChanEtsiFramerProvTable 1.3.6.1.4.1.562.2.4.1.120.10.2.10
This group contains the base provisioning data for the Framer component. Application or hardware interface specific provisioning data is contained in other provisionable Framer groups.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DataSigChanEtsiFramerProvEntry

dataSigChanEtsiFramerProvEntry 1.3.6.1.4.1.562.2.4.1.120.10.2.10.1
An entry in the dataSigChanEtsiFramerProvTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DataSigChanEtsiFramerProvEntry  

dataSigChanEtsiFramerInterfaceName 1.3.6.1.4.1.562.2.4.1.120.10.2.10.1.1
This attribute contains a hardware component name. The attribute associates the application with a specific link. This defines the module processor on which Framer's parent component (as well as Framer itself) will run.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Link  

dataSigChanEtsiFramerStateTable 1.3.6.1.4.1.562.2.4.1.120.10.2.12
This group contains the three OSI State attributes. The descriptions generically indicate what each state attribute implies about the component. Note that not all the values and state combinations described here are supported by every component which uses this group. For component-specific information and the valid state combinations, refer to NTP 241-7001-150, Passport Operations and Maintenance Guide.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DataSigChanEtsiFramerStateEntry

dataSigChanEtsiFramerStateEntry 1.3.6.1.4.1.562.2.4.1.120.10.2.12.1
An entry in the dataSigChanEtsiFramerStateTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DataSigChanEtsiFramerStateEntry  

dataSigChanEtsiFramerAdminState 1.3.6.1.4.1.562.2.4.1.120.10.2.12.1.1
This attribute indicates the OSI Administrative State of the component. The value locked indicates that the component is administratively prohibited from providing services for its users. A Lock or Lock - force command has been previously issued for this component. When the value is locked, the value of usageState must be idle. The value shuttingDown indicates that the component is administratively permitted to provide service to its existing users only. A Lock command was issued against the component and it is in the process of shutting down. The value unlocked indicates that the component is administratively permitted to provide services for its users. To enter this state, issue an Unlock command to this component.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER locked(0), unlocked(1), shuttingDown(2)  

dataSigChanEtsiFramerOperationalState 1.3.6.1.4.1.562.2.4.1.120.10.2.12.1.2
This attribute indicates the OSI Operational State of the component. The value enabled indicates that the component is available for operation. Note that if adminState is locked, it would still not be providing service. The value disabled indicates that the component is not available for operation. For example, something is wrong with the component itself, or with another component on which this one depends. If the value is disabled, the usageState must be idle.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

dataSigChanEtsiFramerUsageState 1.3.6.1.4.1.562.2.4.1.120.10.2.12.1.3
This attribute indicates the OSI Usage State of the component. The value idle indicates that the component is not currently in use. The value active indicates that the component is in use and has spare capacity to provide for additional users. The value busy indicates that the component is in use and has no spare operating capacity for additional users at this time.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER idle(0), active(1), busy(2)  

dataSigChanEtsiFramerStatsTable 1.3.6.1.4.1.562.2.4.1.120.10.2.13
This group contains the operational statistics data for a Framer component.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DataSigChanEtsiFramerStatsEntry

dataSigChanEtsiFramerStatsEntry 1.3.6.1.4.1.562.2.4.1.120.10.2.13.1
An entry in the dataSigChanEtsiFramerStatsTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DataSigChanEtsiFramerStatsEntry  

dataSigChanEtsiFramerFrmToIf 1.3.6.1.4.1.562.2.4.1.120.10.2.13.1.1
This attribute counts the number of frames transmitted to the link interface by Framer. This count wraps to zero after reaching its maximum value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

dataSigChanEtsiFramerFrmFromIf 1.3.6.1.4.1.562.2.4.1.120.10.2.13.1.2
This attribute counts the number of frames received from the link interface by Framer. This count wraps to zero after reaching its maximum value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

dataSigChanEtsiFramerOctetFromIf 1.3.6.1.4.1.562.2.4.1.120.10.2.13.1.3
The number of bytes received from the link interface by Framer.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

dataSigChanEtsiFramerAborts 1.3.6.1.4.1.562.2.4.1.120.10.2.13.1.4
This attribute counts the total number of aborts received. This count wraps to zero after reaching its maximum value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

dataSigChanEtsiFramerCrcErrors 1.3.6.1.4.1.562.2.4.1.120.10.2.13.1.5
This attribute counts the total number of frames with CRC errors. This count wraps to zero after reaching its maximum value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

dataSigChanEtsiFramerLrcErrors 1.3.6.1.4.1.562.2.4.1.120.10.2.13.1.6
This attribute counts the total number of frames with LRC errors. This count wraps to zero after reaching its maximum value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

dataSigChanEtsiFramerNonOctetErrors 1.3.6.1.4.1.562.2.4.1.120.10.2.13.1.7
This attribute counts the total number of frames that were non octet aligned. This count wraps to zero after reaching its maximum value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

dataSigChanEtsiFramerOverruns 1.3.6.1.4.1.562.2.4.1.120.10.2.13.1.8
This attribute counts the total number of frames received from the link for which overruns occurred. This count wraps to zero after reaching its maximum value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

dataSigChanEtsiFramerUnderruns 1.3.6.1.4.1.562.2.4.1.120.10.2.13.1.9
This attribute counts the total number of frames transmitted to the link for which underruns occurred. This count wraps to zero after reaching its maximum value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

dataSigChanEtsiFramerLargeFrmErrors 1.3.6.1.4.1.562.2.4.1.120.10.2.13.1.10
This attribute counts the total number of frames received which were too large. The frame was longer than 500 bytes. This count wraps to zero after reaching its maximum value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

disdnETSIGroup 1.3.6.1.4.1.562.2.4.2.117.1
OBJECT IDENTIFIER    

disdnETSIGroupBE 1.3.6.1.4.1.562.2.4.2.117.1.5
OBJECT IDENTIFIER    

disdnETSIGroupBE00 1.3.6.1.4.1.562.2.4.2.117.1.5.1
OBJECT IDENTIFIER    

disdnETSIGroupBE00A 1.3.6.1.4.1.562.2.4.2.117.1.5.1.2
OBJECT IDENTIFIER    

disdnETSICapabilities 1.3.6.1.4.1.562.2.4.2.117.3
OBJECT IDENTIFIER    

disdnETSICapabilitiesBE 1.3.6.1.4.1.562.2.4.2.117.3.5
OBJECT IDENTIFIER    

disdnETSICapabilitiesBE00 1.3.6.1.4.1.562.2.4.2.117.3.5.1
OBJECT IDENTIFIER    

disdnETSICapabilitiesBE00A 1.3.6.1.4.1.562.2.4.2.117.3.5.1.2
OBJECT IDENTIFIER