NSCRTV-ROOT

File: NSCRTV-ROOT.mib (45499 bytes)

Imported modules

RFC1155-SMI SNMPv2-TC

Imported symbols

enterprises OBJECT-TYPE IpAddress
DisplayString NetworkAddress Counter

Defined Types

AnalogPropertyEntry  
SEQUENCE    
  analogParameterOID OBJECT IDENTIFIER
  alarmEnable OCTET STRING
  analogAlarmState INTEGER
  analogAlarmHIHI INTEGER
  analogAlarmHI INTEGER
  analogAlarmLO INTEGER
  analogAlarmLOLO INTEGER
  analogAlarmDeadband INTEGER

DiscretePropertyEntry  
SEQUENCE    
  discreteParameterOID OBJECT IDENTIFIER
  discreteAlarmValue INTEGER
  discreteAlarmEnable INTEGER
  discreteAlarmState INTEGER

CurrentAlarmEntry  
SEQUENCE    
  currentAlarmOID OBJECT IDENTIFIER
  currentAlarmState INTEGER
  currentAlarmValue INTEGER

AlarmLogEntry  
SEQUENCE    
  alarmLogIndex INTEGER
  alarmLogInformation OCTET STRING

CommonMulticastAddressEntry  
SEQUENCE    
  commonMulticastAddressIndex INTEGER
  commonMulticastAddressNumber OCTET STRING

CommonAgentTrapEntry  
SEQUENCE    
  commonAgentTrapIndex INTEGER
  commonAgentTrapIP IpAddress
  commonAgentTrapCommunity DisplayString
  commonAgentTrapStatus INTEGER

CommonDeviceInfoEntry  
SEQUENCE    
  commonDeviceSlot INTEGER
  commonDevicesID OCTET STRING
  commonDeviceVendor DisplayString
  commonDeviceModelNumber DisplayString
  commonDeviceSerialNumber DisplayString
  commonDeviceVendorInfo DisplayString
  commonDeviceStatus OCTET STRING
  commonDeviceReset INTEGER
  commonDeviceAlarmDetectionControl INTEGER
  commonDeviceMACAddress NetworkAddress
  commonDeviceTamperStatus INTEGER
  commonDeviceInternalTemperature INTEGER
  commonDeviceResetCause INTEGER
  commonDeviceCraftStatus INTEGER
  commonDevicesOID OBJECT IDENTIFIER
  commonDeviceAcct Counter
  commonDeviceName DisplayString
  commonDeviceMFD DisplayString
  commonDeviceFW DisplayString

OaPumpEntry  
SEQUENCE    
  oaPumpIndex INTEGER
  oaPumpBIAS INTEGER
  oaPumpTEC INTEGER
  oaPumpTemp INTEGER

OaDCPowerEntry  
SEQUENCE    
  oaDCPowerIndex INTEGER
  oaDCPowerVoltage INTEGER
  oaDCPowerCurrent INTEGER
  oaDCPowerName DisplayString

Defined Values

nscrtvRoot 1.3.6.1.4.1.17409
OBJECT IDENTIFIER    

nscrtvHFCemsTree 1.3.6.1.4.1.17409.1
OBJECT IDENTIFIER    

propertyIdent 1.3.6.1.4.1.17409.1.1
OBJECT IDENTIFIER    

alarmsIdent 1.3.6.1.4.1.17409.1.2
OBJECT IDENTIFIER    

commonIdent 1.3.6.1.4.1.17409.1.3
OBJECT IDENTIFIER    

tvmodIdent 1.3.6.1.4.1.17409.1.4
OBJECT IDENTIFIER    

qammodIdent 1.3.6.1.4.1.17409.1.5
OBJECT IDENTIFIER    

otdIdent 1.3.6.1.4.1.17409.1.6
OBJECT IDENTIFIER    

otxIdent 1.3.6.1.4.1.17409.1.7
OBJECT IDENTIFIER    

uporIdent 1.3.6.1.4.1.17409.1.8
OBJECT IDENTIFIER    

dorIdent 1.3.6.1.4.1.17409.1.9
OBJECT IDENTIFIER    

fnIdent 1.3.6.1.4.1.17409.1.10
OBJECT IDENTIFIER    

oaIdent 1.3.6.1.4.1.17409.1.11
OBJECT IDENTIFIER    

addIdent 1.3.6.1.4.1.17409.1.12
OBJECT IDENTIFIER    

cacIdent 1.3.6.1.4.1.17409.1.13
OBJECT IDENTIFIER    

lineIdent 1.3.6.1.4.1.17409.1.14
OBJECT IDENTIFIER    

analogPropertyTable 1.3.6.1.4.1.17409.1.1.1
Attribute Table simulation parameters
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AnalogPropertyEntry

analogPropertyEntry 1.3.6.1.4.1.17409.1.1.1.1
Attribute Table simulation parameters head. OID purpose as a table index,Its coding method is'lengthooOID'ooOID former two members'1.3'According to '1'and'3'respectively coding,Instead of ordinary OID encoding (0x2B).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AnalogPropertyEntry  

analogParameterOID 1.3.6.1.4.1.17409.1.1.1.1.1
index
Status: mandatory Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

alarmEnable 1.3.6.1.4.1.17409.1.1.1.1.2
Alarm enable control byte, the corresponding position for the'1 'that allow alarm,'0' a ban warning Bit 0: Alarm enable low Bit 1: Alarm enable low Bit 2: Alarm enable high Bit 3: Alarm enable high Bit 4 ~ 7 reservations should be 0 This object should be stored in nonvolatile memory.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1)  

analogAlarmState 1.3.6.1.4.1.17409.1.1.1.1.3
The parameters of the current state of alarm.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER aasNominal(1), aasHIHI(2), aasHI(3), aasLO(4), aasLOLO(5)  

analogAlarmHIHI 1.3.6.1.4.1.17409.1.1.1.1.4
Alarm HIHI high threshold value. This object should be stored in non-volatile memory.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

analogAlarmHI 1.3.6.1.4.1.17409.1.1.1.1.5
HI high alarm threshold value. This object should be stored in non-volatile memory.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

analogAlarmLO 1.3.6.1.4.1.17409.1.1.1.1.6
LO low alarm threshold value. This object should be stored in non-volatile memory.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

analogAlarmLOLO 1.3.6.1.4.1.17409.1.1.1.1.7
Alarm LOLO very low threshold value. This object should be stored in non-volatile memory.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

analogAlarmDeadband 1.3.6.1.4.1.17409.1.1.1.1.8
Dead-alarm threshold value. After the warning, parameter values should be restored to the alarm threshold and alarm threshold and the difference between the absolute value greater than the value of dead zone, the alarm can be removed. This object should be stored in nonvolatile memory.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

discretePropertyTable 1.3.6.1.4.1.17409.1.1.2
Discrete Attribute Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DiscretePropertyEntry

discretePropertyEntry 1.3.6.1.4.1.17409.1.1.2.1
Attribute Table discrete head. OID coding methods with simulation attribute table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DiscretePropertyEntry  

discreteParameterOID 1.3.6.1.4.1.17409.1.1.2.1.1
Attribute Table discrete index 1: Parameters OID.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

discreteAlarmValue 1.3.6.1.4.1.17409.1.1.2.1.2
Attribute Table discrete index 2: parameter values. When the equipment value of this parameter values, and so will be dealt with a warning.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

discreteAlarmEnable 1.3.6.1.4.1.17409.1.1.2.1.3
When the alarm so that it can open the (2 or 3), this parameter allows for alarm processing. If the alarm so that it can shut down (1), alarm processing will be carried out. This object default values for the disable (1). This object should be stored in non-volatile memory.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enableMajor(2), enableMinor(3)  

discreteAlarmState 1.3.6.1.4.1.17409.1.1.2.1.4
The parameters of the current state of alarm.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER dasNominal(1), dasDiscreteMajor(6), dasDiscreteMinor(7)  

currentAlarmTable 1.3.6.1.4.1.17409.1.1.3
The current warning Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CurrentAlarmEntry

currentAlarmEntry 1.3.6.1.4.1.17409.1.1.3.1
The current warning Table Head. OID coding methods with simulation attribute table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  CurrentAlarmEntry  

currentAlarmOID 1.3.6.1.4.1.17409.1.1.3.1.1
NE, currently in a state of alarm parameters OID Index, and attribute the alarm in the table corresponding parameters OID.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

currentAlarmState 1.3.6.1.4.1.17409.1.1.3.1.2
Warning parameters of the current state of alarm.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER caasHIHI(2), caasHI(3), caasLO(4), caasLOLO(5), caasDiscreteMajor(6), caasDiscreteMinor(7)  

currentAlarmValue 1.3.6.1.4.1.17409.1.1.3.1.3
Alarm parameter's value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

alarmLogNumberOfEntries 1.3.6.1.4.1.17409.1.2.1
Alarm record number of records in the table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

alarmLogLastIndex 1.3.6.1.4.1.17409.1.2.2
Recently a warning the index of the records.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

alarmLogTable 1.3.6.1.4.1.17409.1.2.3
Alarm record form, at least support 16 record. Each table in the registration of a new record, the management agent (transponder) managers should send traps news.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AlarmLogEntry

alarmLogEntry 1.3.6.1.4.1.17409.1.2.3.1
Alarm Sheet Head.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AlarmLogEntry  

alarmLogIndex 1.3.6.1.4.1.17409.1.2.3.1.1
The only logo Alarm Index recorded a record in the table, the index value increased from 1 start of each new record, plus 1 until 32,767, a record index of the re-starts at 1. Acting under the management of storage capacity can be the first choice to delete those records, the specific details in this not to achieve provisions.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..32767  

alarmLogInformation 1.3.6.1.4.1.17409.1.2.3.1.2
Alarm record information, multi-byte strings, defined as follows: Byte 1 ~ 4: Alarm in time (POSIX format, the previous maximum byte) Byte 5: Alarm types (enumeration, definitions see behind) Byte 6: Alarm value after commonNeStatus Byte 7 ~ m: Alarm parameters object identifier (Basic Encoding Rules (ASN.1)) Byte n ~ z: Alarm parameter values (Basic Encoding Rules (ASN.1)) Alarm enumerated types: 1 NOMINAL 2 HIHI 3 HI 4 LO 5 LOLO 6 Discrete Major 7 Discrete Minor
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(17..255)  

alarmText 1.3.6.1.4.1.17409.1.2.4
This trap targets for the needs of information contained in a text field transponder information is achievable. The field contains the text of the object depends on the definition of alarm parameters, it is uncertain, This object can not access provisions.
Status: optional Access: not-accessible
OBJECT-TYPE    
  DisplayString  

hfcAlarmEvent 1
When detected in the event of alarm information sent this trap, whether bundled alarmText variable parameter under warning object to determine. Some of the parameters only need to bind the alarm first three variables.
TRAP-TYPE    

commonAdminGroup 1.3.6.1.4.1.17409.1.3.1
OBJECT IDENTIFIER    

commonAdminUseRf 1.3.6.1.4.1.17409.1.3.2
OBJECT IDENTIFIER    

commonAdminUseEthernet 1.3.6.1.4.1.17409.1.3.3
OBJECT IDENTIFIER    

commonMACGroup 1.3.6.1.4.1.17409.1.3.2.1
OBJECT IDENTIFIER    

commonRfGroup 1.3.6.1.4.1.17409.1.3.2.2
OBJECT IDENTIFIER    

commonMacAddress 1.3.6.1.4.1.17409.1.3.2.1.1
OBJECT IDENTIFIER    

commonBackoffParams 1.3.6.1.4.1.17409.1.3.2.1.2
OBJECT IDENTIFIER    

commonMacStats 1.3.6.1.4.1.17409.1.3.2.1.3
OBJECT IDENTIFIER    

commonAgentGroup 1.3.6.1.4.1.17409.1.3.3.1
OBJECT IDENTIFIER    

commonDeviceGroup 1.3.6.1.4.1.17409.1.3.3.2
OBJECT IDENTIFIER    

commonNELogicalID 1.3.6.1.4.1.17409.1.3.1.1
The logic of the designated NE identifier (LogicID), the values and attributes of other unrelated NE. This target value should be stored in non-volatile memory.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..40)  

commonNEVendor 1.3.6.1.4.1.17409.1.3.1.2
NE equipment manufacturers.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

commonNEModelNumber 1.3.6.1.4.1.17409.1.3.1.3
NE equipment models.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

commonNESerialNumber 1.3.6.1.4.1.17409.1.3.1.4
NE equipment serial numbers.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

commonNEVendorInfo 1.3.6.1.4.1.17409.1.3.1.5
NE equipment suppliers other special designated information.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

commonNEStatus 1.3.6.1.4.1.17409.1.3.1.6
With 7.5.4 STATRESP PDU parameters in the corresponding Status Bit 0: CHNLRQST Bit 1: CNTNRM Bit 2: CNTCUR Bit 3: MAJOR ALARMS Bit 4: MINOR ALARMS Bit 5: RSVD1 Bit 6: RSVD2 Bit 7: RSVD3
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1)  

commonReset 1.3.6.1.4.1.17409.1.3.1.7
Write'1 'will be reset NE equipment, the value will be included in other non-functional. Reading this object return value'1 ', had no effect on equipment.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER reset(1)  

commonAlarmDetectionControl 1.3.6.1.4.1.17409.1.3.1.8
This object used to control the Alarm Detection NE.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER detectionDisabled(1), detectionEnabled(2), detectionEnabledAndRegenerate(3)  

commonNetworkAddress 1.3.6.1.4.1.17409.1.3.1.9
NE network IP address, NE produce Trap should include this address. This value should be stored in nonvolatile memory. This value can be registered through the MAC order or through local vendors to set up Interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  NetworkAddress  

commonCheckCode 1.3.6.1.4.1.17409.1.3.1.10
This target for the detection transponder code configuration of the report. The calculation includes detection code transponder (including management equipment) and the physical configuration parameters stored in non-volatile memory of all the parameters. The detection algorithm calculated by the vendor code provisions. The object should be kept in the value of non-volatile memory, the response thinks highly activated, will be recalculated and re-testing code and the value prior to the commencement of comparison to determine whether or should have hfcColdStart hfcWarmStart traps. When write this object (SetRequest), the detection code will be recalculated and fill the SetRequest in response to the GetResponse. At this time, will not produce or hfcWarmStart traps hfcColdStart.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

commonTrapCommunityString 1.3.6.1.4.1.17409.1.3.1.11
Definition of Community Trap string. The default value is' public '. The value of this object should be stored in non-volatile memory.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

commonTamperStatus 1.3.6.1.4.1.17409.1.3.1.12
The safety report NE switching equipment (such as whether to open up the lid) state that this object is called discrete attributes of a corresponding entry in the table. Intact that normal, expressed alarm compromised.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER intact(1), compromised(2)  

commonInternalTemperature 1.3.6.1.4.1.17409.1.3.1.13
NE equipment Room (machine) temperature, units degrees Celsius. This request object attribute in a corresponding entry in the table.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER -128..127  

commonTime 1.3.6.1.4.1.17409.1.3.1.14
NE of the POSIX said that the current time (since at 0:00 on January 1, 1970 since the seconds).
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER  

commonVarBindings 1.3.6.1.4.1.17409.1.3.1.15
This object can be said to receive SNMP information NE variables bundled the largest number of tables. Value: 0 indicated no restrictions on the maximum number bundled.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

commonResetCause 1.3.6.1.4.1.17409.1.3.1.16
NE said the reasons for the recent reduction.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), powerup(2), command(3), watchdog(4), craft(5)  

commonCraftStatus 1.3.6.1.4.1.17409.1.3.1.17
NE local object that this interface (such as RS232 or RS485 interface) state. NE does not necessarily have to support the local interface. NE local interface without affecting the state of its MAC interface functions; If we do not support the local interface, and its value is disconnected.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER disconnected(1), connected(2)  

commonDeviceOID 1.3.6.1.4.1.17409.1.3.1.18
This OID object as a pointer, the equipment was used at MIB (such as Node, two-way amplifier, etc).
Status: optional Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

commonDeviceId 1.3.6.1.4.1.17409.1.3.1.19
The contents of this object by the designated by the equipment vendors, manufacturers and products it contains special ASCII text messages.
Status: optional Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(32)  

commondownload 1.3.6.1.4.1.17409.1.3.1.20
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER reset(1)  

commonPhysAddress 1.3.6.1.4.1.17409.1.3.2.1.1.1
NE MAC (physical) address.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

commonMaxMulticastAddresses 1.3.6.1.4.1.17409.1.3.2.1.1.2
NE equipment to support the greatest number of multicast addresses.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 4..255  

commonMulticastAddressTable 1.3.6.1.4.1.17409.1.3.2.1.1.3
Multicast addresses Table, the value of this object should be stored in nonvolatile memory.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CommonMulticastAddressEntry

commonMulticastAddressEntry 1.3.6.1.4.1.17409.1.3.2.1.1.3.1
Multicast addresses Table Head.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  CommonMulticastAddressEntry  

commonMulticastAddressIndex 1.3.6.1.4.1.17409.1.3.2.1.1.3.1.1
Multicast addresses Index.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

commonMulticastAddressNumber 1.3.6.1.4.1.17409.1.3.2.1.1.3.1.2
Multicast addresses,I/Gbit
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(6)  

commonBackoffPeriod 1.3.6.1.4.1.17409.1.3.2.1.2.1
Backoff algorithm benchmark time (ms), initialize the default value of 6 ms. The value of this object should be stored in non-volatile memory.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..16383  

commonACKTimeoutWindow 1.3.6.1.4.1.17409.1.3.2.1.2.2
NE awaiting HE overtime to send ACK response time (ms), initialize the default value is 19 ms. The value of this object should be stored in non-volatile memory.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

commonMaximumMACLayerRetries 1.3.6.1.4.1.17409.1.3.2.1.2.3
NE data packets sent the greatest number of re-examination. Initialize the default value is 16. The value of this object should be stored in non-volatile memory.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

commonMaxPayloadSize 1.3.6.1.4.1.17409.1.3.2.1.2.4
From top to bottom line channel packet supported by the largest payload (payload) the length of.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

commonBackoffMinimumExponent 1.3.6.1.4.1.17409.1.3.2.1.2.5
The standards body of the MAC layer specification definition of the smallest backoff algorithm index value, default values for 6. This value may not exceed commonBackoffMaximumValue value. The value of this object should be stored in non-volatile memory.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..15  

commonBackoffMaximumExponent 1.3.6.1.4.1.17409.1.3.2.1.2.6
The body of the MAC layer standard definition of backoff algorithm for standardizing the largest index value, the default value is 15. This value shall be not less than commonBackoffMinimum value. The value of this object should be stored in non-volatile memory.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..15  

commonForwardPathLOSEvents 1.3.6.1.4.1.17409.1.3.2.1.3.1
LOS downlink channel in the number of reset to 0.
Status: optional Access: read-write
OBJECT-TYPE    
  Counter  

commonForwardPathFramingErrors 1.3.6.1.4.1.17409.1.3.2.1.3.2
Downlink Channel frames wrong number reset to 0.
Status: optional Access: read-write
OBJECT-TYPE    
  Counter  

commonForwardPathCRCErrors 1.3.6.1.4.1.17409.1.3.2.1.3.3
CRC errors down the number of reset to 0.
Status: optional Access: read-write
OBJECT-TYPE    
  Counter  

commonInvalidMacCmds 1.3.6.1.4.1.17409.1.3.2.1.3.4
Invalid MAC layer order wrong number reset to 0.
Status: optional Access: read-write
OBJECT-TYPE    
  Counter  

commonBackwardPathCollisionTimes 1.3.6.1.4.1.17409.1.3.2.1.3.5
Uplink Packet collision frequency, reset to 0.
Status: optional Access: read-write
OBJECT-TYPE    
  Counter  

commonReturnPathFrequency 1.3.6.1.4.1.17409.1.3.2.2.1
Channel uplink frequency units Hz. The value of this object should be stored in non-volatile memory.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1000000000  

commonForwardPathFrequency 1.3.6.1.4.1.17409.1.3.2.2.2
Downlink frequency channel, flat Hz. The value of this object should be stored in non-volatile memory.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1000000000  

commonProvisionedReturnPowerLevel 1.3.6.1.4.1.17409.1.3.2.2.3
Upstream channel power levels and units for dBuV. When the internal use of this value will be rounded to the nearest support value. Reading return to this subject when the actual value rather than rounding value. The value of this object should be stored in non-volatile memory.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..127  

commonForwardPathReceiveLevel 1.3.6.1.4.1.17409.1.3.2.2.4
Downlink Channel receive power levels, units dBuV.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..127  

commonMaxReturnPower 1.3.6.1.4.1.17409.1.3.2.2.5
The largest upstream channel power levels and units for dBuV. The value of this object should be stored in non-volatile memory.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..127  

commonAgentBootWay 1.3.6.1.4.1.17409.1.3.3.1.1
Starting Method Acting
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER bootDefault(1), bootBOOTP(2), bootTFTP(3)  

commonAgentReset 1.3.6.1.4.1.17409.1.3.3.1.2
Acting Restart, write'1 'will enable agents to restart, the value will be included in other non-functional. Reading this object return value'1 ', the agent had no effect on.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER reset(1)  

commonAgentMaxTraps 1.3.6.1.4.1.17409.1.3.3.1.3
Acting detected alarm when sent to the management of the largest number of TRAP, 0 that manufacturers use the default default values.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

commonAgentTrapMinInterval 1.3.6.1.4.1.17409.1.3.3.1.4
Acting TRAP send the minimum spacing units for s.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

commonAgentTrapMaxInterval 1.3.6.1.4.1.17409.1.3.3.1.5
Acting TRAP send the largest spacing units for s.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

commonTrapAck 1.3.6.1.4.1.17409.1.3.3.1.6
The variables used to notify Snmp agents, it issued the warning Trap has received information management console, do not have to re-hair. The content of the variables in alarmLogInformation MIB and the same warning. Agents received after the adoption of alarmLogInformation management can clearly know the host response is a warning which Trap information, thereby stop the alarm information re the Trap.
Status: optional Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(17..255)  

commonAgentTrapTable 1.3.6.1.4.1.17409.1.3.3.1.7
Acting Information Table TRAP.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CommonAgentTrapEntry

commonAgentTrapEntry 1.3.6.1.4.1.17409.1.3.3.1.7.1
Acting Head TRAP Information Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  CommonAgentTrapEntry  

commonAgentTrapIndex 1.3.6.1.4.1.17409.1.3.3.1.7.1.1
TRAP Table Index.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

commonAgentTrapIP 1.3.6.1.4.1.17409.1.3.3.1.7.1.2
When the purpose of the TRAP host's IP address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

commonAgentTrapCommunity 1.3.6.1.4.1.17409.1.3.3.1.7.1.3
Send the Community string TRAP.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..64)  

commonAgentTrapStatus 1.3.6.1.4.1.17409.1.3.3.1.7.1.4
It said the opening of the TRAP.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER commonAgentTrapEnable(1), commonAgentTrapDisable(2)  

commonDeviceNum 1.3.6.1.4.1.17409.1.3.3.2.1
The agent said that the current management is the number of devices.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

commonDeviceInfoTable 1.3.6.1.4.1.17409.1.3.3.2.2
Acting is currently public information management equipment List.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CommonDeviceInfoEntry

commonDeviceInfoEntry 1.3.6.1.4.1.17409.1.3.3.2.2.1
Acting is currently public information management equipment list Table Head.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  CommonDeviceInfoEntry  

commonDeviceSlot 1.3.6.1.4.1.17409.1.3.3.2.2.1.1
Acting is currently under the management of the equipment list of public information table Index.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

commonDevicesID 1.3.6.1.4.1.17409.1.3.3.2.2.1.2
Designated equipment manufacturers logo.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..40)  

commonDeviceVendor 1.3.6.1.4.1.17409.1.3.3.2.2.1.3
Equipment manufacturers.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

commonDeviceModelNumber 1.3.6.1.4.1.17409.1.3.3.2.2.1.4
Equipment Model.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

commonDeviceSerialNumber 1.3.6.1.4.1.17409.1.3.3.2.2.1.5
The string of equipment.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

commonDeviceVendorInfo 1.3.6.1.4.1.17409.1.3.3.2.2.1.6
Equipment suppliers of other special designated information.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

commonDeviceStatus 1.3.6.1.4.1.17409.1.3.3.2.2.1.7
The state equipment Bit 0: RSVD0 Bit 1: RSVD1 Bit 2: RSVD2 Bit 3: MAJOR ALARMS Bit 4: MINOR ALARMS Bit 5: RSVD5 Bit 6: RSVD6 Bit 7: RSVD7
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1)  

commonDeviceReset 1.3.6.1.4.1.17409.1.3.3.2.2.1.8
Write'1 'will be reset equipment, other values will be written into the non-functional. Reading this object return value'1 ', had no effect on equipment.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER reset(1)  

commonDeviceAlarmDetectionControl 1.3.6.1.4.1.17409.1.3.3.2.2.1.9
This object used to control equipment Alarm Detection.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER detectionDisabled(1), detectionEnabled(2), detectionEnabledAndRegenerate(3)  

commonDeviceMACAddress 1.3.6.1.4.1.17409.1.3.3.2.2.1.10
Equipment MAC address.
Status: mandatory Access: read-only
OBJECT-TYPE    
  NetworkAddress  

commonDeviceTamperStatus 1.3.6.1.4.1.17409.1.3.3.2.2.1.11
Report of the safety switch equipment (such as whether to open up the lid) state that this object is called discrete attributes of a corresponding entry in the table. Intact that normal, expressed alarm compromised.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER intact(1), compromised(2)  

commonDeviceInternalTemperature 1.3.6.1.4.1.17409.1.3.3.2.2.1.12
Equipment Room (machine) temperature, units degrees Celsius. This request object attribute in a corresponding entry in the table.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER -128..127  

commonDeviceResetCause 1.3.6.1.4.1.17409.1.3.3.2.2.1.13
Equipment that the reasons for the recent reduction.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), powerup(2), command(3), watchdog(4), craft(5)  

commonDeviceCraftStatus 1.3.6.1.4.1.17409.1.3.3.2.2.1.14
This object interface that local equipment (such as RS232 or RS485 interface) state.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER disconnected(1), connected(2)  

commonDevicesOID 1.3.6.1.4.1.17409.1.3.3.2.2.1.15
Goals identifier string, point to a concrete realization of the equipment.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

commonDeviceAcct 1.3.6.1.4.1.17409.1.3.3.2.2.1.16
Equipment that the accumulated work time, units of s.
Status: optional Access: read-only
OBJECT-TYPE    
  Counter  

commonDeviceName 1.3.6.1.4.1.17409.1.3.3.2.2.1.17
Equipment Name.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

commonDeviceMFD 1.3.6.1.4.1.17409.1.3.3.2.2.1.18
Date of production equipment.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(10)  

commonDeviceFW 1.3.6.1.4.1.17409.1.3.3.2.2.1.19
Firmware information equipment.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

hfcColdStart 0
HfcColdStart traps that are sent to re-initialization protocol entities, and entities agent configuration or agreement may have changed. This trap only after the success of transponder sent registration.
TRAP-TYPE    

hfcWarmStart 2
HfcWarmStart traps that are sent to re-initialization protocol entities, and entities agent configuration or agreement has not changed. This trap only after the completion of transponder sent registration.
TRAP-TYPE    

oaVendorOID 1.3.6.1.4.1.17409.1.11.1
This object provides manufacturers of optical amplifier MIB expansion. Without the expansion, this should be targeting at the optical amplifier nodes oaIdent.
Status: optional Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

oaOutputOpticalPower 1.3.6.1.4.1.17409.1.11.2
The output optical power units to 0.1 dBm, the object attributes required to register an entry MIB.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

oaInputOpticalPower 1.3.6.1.4.1.17409.1.11.3
Input optical power units to 0.1 dBm, the object attributes required to register an entry MIB.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER -128..127  

oaPumpTable 1.3.6.1.4.1.17409.1.11.4
EDFA laser pump Information Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OaPumpEntry

oaPumpEntry 1.3.6.1.4.1.17409.1.11.4.1
Each laser-pumped optical amplifier Information Table Head.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  OaPumpEntry  

oaPumpIndex 1.3.6.1.4.1.17409.1.11.4.1.1
Laser-pumped optical amplifier index value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

oaPumpBIAS 1.3.6.1.4.1.17409.1.11.4.1.2
The pump laser bias current, flat mA, this attribute MIB objects require an entry in the register.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

oaPumpTEC 1.3.6.1.4.1.17409.1.11.4.1.3
Current laser pump refrigeration unit is 0.01 A, this attribute MIB objects require an entry in the register.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER -32768..32767  

oaPumpTemp 1.3.6.1.4.1.17409.1.11.4.1.4
Laser pump temperature, units of 0.10 C, this attribute MIB objects require an entry in the register.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..32768  

oaNumberDCPowerSupply 1.3.6.1.4.1.17409.1.11.5
The number of internal DC power supply, 0 expressed transponder does not support this function.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..16  

oaDCPowerSupplyMode 1.3.6.1.4.1.17409.1.11.6
Power supply mode: load sharing, standby switching or an independent power supply.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER loadsharing(1), switchedRedundant(2), aloneSupply(3)  

oaDCPowerTable 1.3.6.1.4.1.17409.1.11.7
DC Power Information Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OaDCPowerEntry

oaDCPowerEntry 1.3.6.1.4.1.17409.1.11.7.1
DC Power Information Table Head.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  OaDCPowerEntry  

oaDCPowerIndex 1.3.6.1.4.1.17409.1.11.7.1.1
DC Power Index.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

oaDCPowerVoltage 1.3.6.1.4.1.17409.1.11.7.1.2
Supply voltage, the unit is 0.1 V. This attribute MIB objects require an entry in the register.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER -32768..32767  

oaDCPowerCurrent 1.3.6.1.4.1.17409.1.11.7.1.3
Electricity power supply unit is 0.01 A. This attribute MIB objects require an entry in the register.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

oaDCPowerName 1.3.6.1.4.1.17409.1.11.7.1.4
Indicate the name of the power supply, for example: 24 V DC power supply. This field value by the user, should at least be marked with a number of power supply voltage and distinguish between each other. When the object of this table have a warning, that this object should be put into the name of alarmText hfcAlarmEvent traps in the target.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

oaOutputOpticalPowerSet 1.3.6.1.4.1.17409.1.11.11
The output optical power control ,units to 0.1 dBm
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

oaGainSet 1.3.6.1.4.1.17409.1.11.12
units to 0.1 dB
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

powerSupplyStatusA 1.3.6.1.4.1.17409.1.11.32
Returns the operating status of power supply A.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER undefined(0), nominal(1), failure(2), notInstalled(3)  

powerSupplyStatusB 1.3.6.1.4.1.17409.1.11.33
Returns the operating status of power supply B.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER undefined(0), nominal(1), failure(2), notInstalled(3)