NMS-EPON-ONU-OPTICAL-PARAM-ALARM-SET

File: NMS-EPON-ONU-OPTICAL-PARAM-ALARM-SET.mib (22822 bytes)

Imported modules

SNMPv2-SMI SNMPv2-CONF NMS-EPON-ONU
SNMPv2-TC

Imported symbols

MODULE-IDENTITY OBJECT-TYPE NOTIFICATION-TYPE
Integer32 Unsigned32 MODULE-COMPLIANCE
OBJECT-GROUP NOTIFICATION-GROUP nmsEponOnu
RowStatus

Defined Types

OnuOpticsParameterAlarmSetEntry  
SEQUENCE    
  ifIndex INTEGER
  txPowerAlarmUpLimitEnable INTEGER
  txPowerAlarmUpLimitThreshold INTEGER
  txPowerAlarmUpLimitClearThreshold INTEGER
  txPowerAlarmUpLimitRowStatus RowStatus
  txPowerAlarmLowLimitEnable INTEGER
  txPowerAlarmLowLimitThreshold INTEGER
  txPowerAlarmLowLimitClearThreshold INTEGER
  txPowerAlarmLowLimitRowStatus RowStatus
  rxPowerAlarmUpLimitEnable INTEGER
  rxPowerAlarmUpLimitThreshold INTEGER
  rxPowerAlarmUpLimitClearThreshold INTEGER
  rxPowerAlarmUpLimitRowStatus RowStatus
  rxPowerAlarmLowLimitEnable INTEGER
  rxPowerAlarmLowLimitThreshold INTEGER
  rxPowerAlarmLowLimitClearThreshold INTEGER
  rxPowerAlarmLowLimitRowStatus RowStatus
  temperatureAlarmUpLimitEnable INTEGER
  temperatureAlarmUpLimitThreshold INTEGER
  temperatureAlarmUpLimitClearThreshold INTEGER
  temperatureAlarmUpLimitRowStatus RowStatus
  temperatureAlarmLowLimitEnable INTEGER
  temperatureAlarmLowLimitThreshold INTEGER
  temperatureAlarmLowLimitClearThreshold INTEGER
  temperatureAlarmLowLimitRowStatus RowStatus
  voltageAlarmUpLimitEnable INTEGER
  voltageAlarmUpLimitThreshold INTEGER
  voltageAlarmUpLimitClearThreshold INTEGER
  voltageAlarmUpLimitRowStatus RowStatus
  voltageAlarmLowLimitEnable INTEGER
  voltageAlarmLowLimitThreshold INTEGER
  voltageAlarmLowLimitClearThreshold INTEGER
  voltageAlarmLowLimitRowStatus RowStatus
  currentAlarmUpLimitEnable INTEGER
  currentAlarmUpLimitThreshold INTEGER
  currentAlarmUpLimitClearThreshold INTEGER
  currentAlarmUpLimitRowStatus RowStatus
  currentAlarmLowLimitEnable INTEGER
  currentAlarmLowLimitThreshold INTEGER
  currentAlarmLowLimitClearThreshold INTEGER
  currentAlarmLowLimitRowStatus RowStatus

Defined Values

onuOpticsParameterAlarmSet 1.3.6.1.4.1.3320.101.10.6
OBJECT IDENTIFIER    

onuOpticsParameterAlarmSetTable 1.3.6.1.4.1.3320.101.10.6.1
A list of epon onu Optics Parameter Alarm Set table entries.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OnuOpticsParameterAlarmSetEntry

onuOpticsParameterAlarmSetEntry 1.3.6.1.4.1.3320.101.10.6.1.1
A collection of additional objects in the epon onu Optics Parameter AlarmSet property table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  OnuOpticsParameterAlarmSetEntry  

ifIndex 1.3.6.1.4.1.3320.101.10.6.1.1.1
The only llid of ONU device in System.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

txPowerAlarmUpLimitEnable 1.3.6.1.4.1.3320.101.10.6.1.1.2
Enable or disable the alarm of PON hign TX power. 1-enable, 2-disable. Default is disable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

txPowerAlarmUpLimitThreshold 1.3.6.1.4.1.3320.101.10.6.1.1.3
The upper threshold of tx power alarm. The unit is 0.1DBm. The range is -400-82. Default is 82.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER -400..82  

txPowerAlarmUpLimitClearThreshold 1.3.6.1.4.1.3320.101.10.6.1.1.4
The upper threshold of tx power alarm. The unit is 0.1DBm. The range is -400-82. Default is 82.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER -400..82  

txPowerAlarmUpLimitRowStatus 1.3.6.1.4.1.3320.101.10.6.1.1.5
The row status of tx power upper alarm.
Status: mandatory Access: read-create
OBJECT-TYPE    
  RowStatus  

txPowerAlarmLowLimitEnable 1.3.6.1.4.1.3320.101.10.6.1.1.6
Enable or disable the alarm of PON low TX power. 1-enable, 2-disable. Default is disable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

txPowerAlarmLowLimitThreshold 1.3.6.1.4.1.3320.101.10.6.1.1.7
The low threshold of tx power alarm. The unit is 0.1DBm. The range is -400-82. Default is -400.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER -400..82  

txPowerAlarmLowLimitClearThreshold 1.3.6.1.4.1.3320.101.10.6.1.1.8
The low threshold tx power alarm cleared. The unit is 0.1DBm. The range is -400-82. Default is -400.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER -400..82  

txPowerAlarmLowLimitRowStatus 1.3.6.1.4.1.3320.101.10.6.1.1.9
The row status of tx power low alarm.
Status: mandatory Access: read-create
OBJECT-TYPE    
  RowStatus  

rxPowerAlarmUpLimitEnable 1.3.6.1.4.1.3320.101.10.6.1.1.10
Enable or disable the alarm of PON hign RX power. 1-enable, 2-disable. Default is disable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

rxPowerAlarmUpLimitThreshold 1.3.6.1.4.1.3320.101.10.6.1.1.11
The upper threshold of rx power alarm. The unit is 0.1DBm. The range is -400-82. Default is 82.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER -400..82  

rxPowerAlarmUpLimitClearThreshold 1.3.6.1.4.1.3320.101.10.6.1.1.12
The upper threshold rx power alarm cleared. The unit is 0.1DBm. The range is -400-82. Default is 82.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER -400..82  

rxPowerAlarmUpLimitRowStatus 1.3.6.1.4.1.3320.101.10.6.1.1.13
The row status of rx power upper alarm.
Status: mandatory Access: read-create
OBJECT-TYPE    
  RowStatus  

rxPowerAlarmLowLimitEnable 1.3.6.1.4.1.3320.101.10.6.1.1.14
Enable or disable the alarm of PON low RX power. 1-enable, 2-disable. Default is disable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

rxPowerAlarmLowLimitThreshold 1.3.6.1.4.1.3320.101.10.6.1.1.15
The low threshold of rx power alarm. The unit is 0.1DBm. The range is -400-82. Default is -400.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER -400..82  

rxPowerAlarmLowLimitClearThreshold 1.3.6.1.4.1.3320.101.10.6.1.1.16
The low threshold rx power alarm cleared. The unit is 0.1DBm. The range is -400-82. Default is -400.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER -400..82  

rxPowerAlarmLowLimitRowStatus 1.3.6.1.4.1.3320.101.10.6.1.1.17
The row status of rx power low alarm.
Status: mandatory Access: read-create
OBJECT-TYPE    
  RowStatus  

temperatureAlarmUpLimitEnable 1.3.6.1.4.1.3320.101.10.6.1.1.18
Enable or disable the alarm of PON high temperature. 1-enable, 2-disable. Default is disable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

temperatureAlarmUpLimitThreshold 1.3.6.1.4.1.3320.101.10.6.1.1.19
The upper threshold of temperature alarm. The unit is 0.1 degree. The range is -1280-1280. Default is 1280.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER -1280..1280  

temperatureAlarmUpLimitClearThreshold 1.3.6.1.4.1.3320.101.10.6.1.1.20
The upper threshold temperature alarm cleared. The unit is 0.1 degree. The range is -1280-1280. Default is 1280.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER -1280..1280  

temperatureAlarmUpLimitRowStatus 1.3.6.1.4.1.3320.101.10.6.1.1.21
The row status of temperature upper alarm.
Status: mandatory Access: read-create
OBJECT-TYPE    
  RowStatus  

temperatureAlarmLowLimitEnable 1.3.6.1.4.1.3320.101.10.6.1.1.22
Enable or disable the alarm of PON low temperature. 1-enable, 2-disable. Default is disable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

temperatureAlarmLowLimitThreshold 1.3.6.1.4.1.3320.101.10.6.1.1.23
The low threshold of temperature alarm. The unit is 0.1 degree. The range is -1280-1280. Default is -1280.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER -1280..1280  

temperatureAlarmLowLimitClearThreshold 1.3.6.1.4.1.3320.101.10.6.1.1.24
The low threshold temperature alarm cleared. The unit is 0.1 degree. The range is -1280-1280. Default is -1280.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER -1280..1280  

temperatureAlarmLowLimitRowStatus 1.3.6.1.4.1.3320.101.10.6.1.1.25
The row status of temperature low alarm.
Status: mandatory Access: read-create
OBJECT-TYPE    
  RowStatus  

voltageAlarmUpLimitEnable 1.3.6.1.4.1.3320.101.10.6.1.1.26
Enable or disable the alarm of PON high voltage. 1-enable, 2-disable. Default is disable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

voltageAlarmUpLimitThreshold 1.3.6.1.4.1.3320.101.10.6.1.1.27
The upper threshold of voltage alarm. The unit is 0.1V. The range is 0-65. Default is 65.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65  

voltageAlarmUpLimitClearThreshold 1.3.6.1.4.1.3320.101.10.6.1.1.28
The upper threshold voltage alarm cleared. The unit is 0.1V. The range is 0-65. Default is 65.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65  

voltageAlarmUpLimitRowStatus 1.3.6.1.4.1.3320.101.10.6.1.1.29
The row status of voltage upper alarm.
Status: mandatory Access: read-create
OBJECT-TYPE    
  RowStatus  

voltageAlarmLowLimitEnable 1.3.6.1.4.1.3320.101.10.6.1.1.30
Enable or disable the alarm of PON low voltage. 1-enable, 2-disable. Default is disable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

voltageAlarmLowLimitThreshold 1.3.6.1.4.1.3320.101.10.6.1.1.31
The low threshold of voltage alarm. The unit is 0.1V. The range is 0-65. Default is 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65  

voltageAlarmLowLimitClearThreshold 1.3.6.1.4.1.3320.101.10.6.1.1.32
The low threshold voltage alarm cleared. The unit is 0.1V. The range is 0-65. Default is 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65  

voltageAlarmLowLimitRowStatus 1.3.6.1.4.1.3320.101.10.6.1.1.33
The row status of voltage low alarm.
Status: mandatory Access: read-create
OBJECT-TYPE    
  RowStatus  

currentAlarmUpLimitEnable 1.3.6.1.4.1.3320.101.10.6.1.1.34
Enable or disable the alarm of PON high current. 1-enable, 2-disable. Default is disable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

currentAlarmUpLimitThreshold 1.3.6.1.4.1.3320.101.10.6.1.1.35
The upper threshold of current alarm. The unit is 0.1mA. The range is 0-1310. Default is 1310.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1310  

currentAlarmUpLimitClearThreshold 1.3.6.1.4.1.3320.101.10.6.1.1.36
The upper threshold current alarm cleared. The unit is 0.1mA. The range is 0-1310. Default is 1310.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1310  

currentAlarmUpLimitRowStatus 1.3.6.1.4.1.3320.101.10.6.1.1.37
The row status of current upper alarm.
Status: mandatory Access: read-create
OBJECT-TYPE    
  RowStatus  

currentAlarmLowLimitEnable 1.3.6.1.4.1.3320.101.10.6.1.1.38
Enable or disable the alarm of PON low current. 1-enable, 2-disable. Default is disable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

currentAlarmLowLimitThreshold 1.3.6.1.4.1.3320.101.10.6.1.1.39
The low threshold of current alarm. The unit is 0.1mA. The range is 0-1310. Default is 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1310  

currentAlarmLowLimitClearThreshold 1.3.6.1.4.1.3320.101.10.6.1.1.40
The low threshold current alarm cleared. The unit is 0.1mA. The range is 0-1310. Default is 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1310  

currentAlarmLowLimitRowStatus 1.3.6.1.4.1.3320.101.10.6.1.1.41
The row status of current low alarm.
Status: mandatory Access: read-create
OBJECT-TYPE    
  RowStatus