NBFLT-MIB

File: NBFLT-MIB.mib (5783 bytes)

Imported modules

NT-Reference-MIB RFC-1212 RFC-1215
RFC1155-SMI SNMPv2-TC

Imported symbols

ngen OBJECT-TYPE TRAP-TYPE
Counter DisplayString

Defined Values

nGenBase 1.3.6.1.4.1.562.3.8.1
OBJECT IDENTIFIER    

nbFltMngmt 1.3.6.1.4.1.562.3.8.1.5
OBJECT IDENTIFIER    

nbFltSNMPAgent 1.3.6.1.4.1.562.3.8.1.5.1
OBJECT IDENTIFIER    

nbFltSNMPAgentStatus 1.3.6.1.4.1.562.3.8.1.5.1.1
OBJECT IDENTIFIER    

nbFltTrapOnAlarm 1.3.6.1.4.1.562.3.8.1.5.1.1.1
Allows turning on or off forwarding of MAS alarms as traps. If this variable has the 'on' value, each alarm will be propagated as a trap. In case of the 'off' value it will not be.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(0), on(1)  

nbFltAgentRunningState 1.3.6.1.4.1.562.3.8.1.5.1.1.2
Defines the current state of the interaction between the SNMP Agent and the MAS Fault Management system. If the MAS SNMP Agent is unable to register with the MAS Fault Mngmt system after startup, it will report a 'notRegistered' value. When registered, will report a 'registered' value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notRegistered(0), registered(1)  

nbFltAlarmTrapFormat 1.3.6.1.4.1.562.3.8.1.5.1.2
OBJECT IDENTIFIER    

nbFltAlarmSymposiumTrapFormat 1.3.6.1.4.1.562.3.8.1.5.1.2.1
Turns on or off generating traps in MAS format.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(0), on(1)  

nbFltAlarmCybeleTrapFormat 1.3.6.1.4.1.562.3.8.1.5.1.2.2
Turns on or off generating traps in Cybele format.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(0), on(1)  

nbFltTrapObjects 1.3.6.1.4.1.562.3.8.1.5.2
OBJECT IDENTIFIER    

nbFltAlarmTrapObjects 1.3.6.1.4.1.562.3.8.1.5.2.1
OBJECT IDENTIFIER    

nbFltAlarmSequence 1.3.6.1.4.1.562.3.8.1.5.2.1.1
This object defines the alarm sequence number
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Counter  

nbFltAlarmTimeStamp 1.3.6.1.4.1.562.3.8.1.5.2.1.2
This object defines the time when alarm was raised
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DisplayString Size(0..16)  

nbFltAlarmEventCode 1.3.6.1.4.1.562.3.8.1.5.2.1.3
This object defines the MAS event code for the generated alarm.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER  

nbFltAlarmEventType 1.3.6.1.4.1.562.3.8.1.5.2.1.4
This object defines the type of the event.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER unknown(0), set(1), clear(2), message(4)  

nbFltAlarmEventSeverity 1.3.6.1.4.1.562.3.8.1.5.2.1.5
This object defines the severity of the reported alarm.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER indeterminate(0), critical(1), major(2), minor(3)  

nbFltAlarmTenantID 1.3.6.1.4.1.562.3.8.1.5.2.1.6
This object defines the tenant ID
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER  

nbFltAlarmCustomerID 1.3.6.1.4.1.562.3.8.1.5.2.1.7
This object defines the customer ID
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER  

nbFltAlarmOriginator 1.3.6.1.4.1.562.3.8.1.5.2.1.8
This object describes the subsystem which raised the alarm.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DisplayString Size(0..32)  

nbFltAlarmDescription 1.3.6.1.4.1.562.3.8.1.5.2.1.9
This object describes what happened in the system, which caused the alarm to occur.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DisplayString Size(0..256)  

nbFltTraps 1.3.6.1.4.1.562.3.8.1.5.3
OBJECT IDENTIFIER    

nbSymposiumAlarmTrap 1
MAS Trap conveying information about raised alarm.
TRAP-TYPE