MSERIES-ALARM-MIB

File: MSERIES-ALARM-MIB.mib (25855 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC SNMPv2-CONF
MSERIES-TC MSERIES-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE NOTIFICATION-TYPE
Unsigned32 Counter32 Integer32
DisplayString DateAndTime MODULE-COMPLIANCE
OBJECT-GROUP NOTIFICATION-GROUP AlarmPerceivedSeverity
AlarmNotificationType AlarmProbableCause UnitType
PortType mseries

Defined Types

AlarmEntry  
SEQUENCE    
  alarmIndex Unsigned32
  alarmUnit UnitType
  alarmPort Integer32
  alarmText DisplayString
  alarmSeverity AlarmPerceivedSeverity
  alarmActivationTime DateAndTime
  alarmCeaseTime DateAndTime
  alarmSeqNumber Counter32
  alarmHostName DisplayString
  alarmPortName DisplayString
  alarmPortType PortType
  alarmType AlarmNotificationType
  alarmCause AlarmProbableCause
  alarmPortAlias DisplayString

AlarmLogEntry  
SEQUENCE    
  alarmLogIndex Unsigned32
  alarmLogUnit UnitType
  alarmLogPort Integer32
  alarmLogText DisplayString
  alarmLogSeverity AlarmPerceivedSeverity
  alarmLogActivationTime DateAndTime
  alarmLogCeaseTime DateAndTime
  alarmLogSeqNumber Counter32
  alarmLogHostName DisplayString
  alarmLogPortName DisplayString
  alarmLogPortType PortType
  alarmLogType AlarmNotificationType
  alarmLogCause AlarmProbableCause

Defined Values

smartAlarm 1.3.6.1.4.1.30826.1.1
This is the enterprise specific Alarm MIB for SmartOptics M-Series
MODULE-IDENTITY    

alarmGeneral 1.3.6.1.4.1.30826.1.1.1
OBJECT IDENTIFIER    

alarmActiveList 1.3.6.1.4.1.30826.1.1.2
OBJECT IDENTIFIER    

alarmLogList 1.3.6.1.4.1.30826.1.1.3
OBJECT IDENTIFIER    

alarmNotifications 1.3.6.1.4.1.30826.1.1.4
OBJECT IDENTIFIER    

smartAlarmMIBConformance 1.3.6.1.4.1.30826.1.1.5
OBJECT IDENTIFIER    

smartAlarmGroups 1.3.6.1.4.1.30826.1.1.5.1
OBJECT IDENTIFIER    

smartAlarmCompliances 1.3.6.1.4.1.30826.1.1.5.2
OBJECT IDENTIFIER    

smartAlarmGeneralLastSeqNumber 1.3.6.1.4.1.30826.1.1.1.1
The sequence number of the last sent notification.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

smartAlarmGeneralHighestSeverity 1.3.6.1.4.1.30826.1.1.1.2
The current highest severity of the active alarms.
Status: current Access: read-only
OBJECT-TYPE    
  AlarmPerceivedSeverity  

smartAlarmGeneralNumberActiveList 1.3.6.1.4.1.30826.1.1.1.3
The number of active alarms in the alarmActiveList.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

smartAlarmGeneralNumberLogList 1.3.6.1.4.1.30826.1.1.1.4
The number of alarms in the alarmLogList.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

alarmActiveTable 1.3.6.1.4.1.30826.1.1.2.1
The active alarm list.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AlarmEntry

alarmEntry 1.3.6.1.4.1.30826.1.1.2.1.1
An entry in the active alarm list.
Status: current Access: not-accessible
OBJECT-TYPE    
  AlarmEntry  

alarmIndex 1.3.6.1.4.1.30826.1.1.2.1.1.1
An unique index assigned to each alarm.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 1..2147483647  

alarmUnit 1.3.6.1.4.1.30826.1.1.2.1.1.2
The alarming unit associated with this alarm. undefined(0), nmb(1), psu1(2), psu2(3), fan(4), system(5), slaveNmb(6), slavePsu1(7), slavePsu2(8), slaveFan(9).
Status: current Access: read-only
OBJECT-TYPE    
  UnitType  

alarmPort 1.3.6.1.4.1.30826.1.1.2.1.1.3
The alarming port associated with this alarm. 1-10 is Line Ports. 11 and higher is Client ports. For non port alarms this value is 0.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

alarmText 1.3.6.1.4.1.30826.1.1.2.1.1.4
The additional text for the alarm.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

alarmSeverity 1.3.6.1.4.1.30826.1.1.2.1.1.5
The severity of the alarm as defined in ITU-T X.733.
Status: current Access: read-only
OBJECT-TYPE    
  AlarmPerceivedSeverity  

alarmActivationTime 1.3.6.1.4.1.30826.1.1.2.1.1.6
The time when the alarm was created.
Status: current Access: read-only
OBJECT-TYPE    
  DateAndTime  

alarmCeaseTime 1.3.6.1.4.1.30826.1.1.2.1.1.7
The time when the alarm was ceased.
Status: current Access: read-only
OBJECT-TYPE    
  DateAndTime  

alarmSeqNumber 1.3.6.1.4.1.30826.1.1.2.1.1.8
The last sequence number used when issuing a notification for this alarm.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

alarmHostName 1.3.6.1.4.1.30826.1.1.2.1.1.9
The hostname.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

alarmPortName 1.3.6.1.4.1.30826.1.1.2.1.1.10
The Port Name.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

alarmPortType 1.3.6.1.4.1.30826.1.1.2.1.1.11
The Port Type. undefined(0), rx(1), tx(2), biDi(3).
Status: current Access: read-only
OBJECT-TYPE    
  PortType  

alarmType 1.3.6.1.4.1.30826.1.1.2.1.1.12
The type of alarm as defined in ITU-T X.733 undefined (0), other (1), communicationsAlarm (2), qualityOfServiceAlarm (3), processingErrorAlarm (4), equipmentAlarm (5), environmental (6), integrityViolation (7), operationalViolation (8), physicalViolation(9), securityServiceOrMechanismViloation (10), timeDomainViolation (11)
Status: current Access: read-only
OBJECT-TYPE    
  AlarmNotificationType  

alarmCause 1.3.6.1.4.1.30826.1.1.2.1.1.13
The alarm probable cause as defined in ITU-T X.733. undefined (0) adapterError (1) -- Equipment applicationSubsystemFailure (2) -- Processing bandwidthReduced (3) -- Quality of service callEstablishmentError (4) -- Communications communicationsProtocolError (5) -- Communications communicationsSubsystemFailure (6) -- Communications configurationOrCustomizationError (7) -- Processing congestion (8) -- Quality of service corruptData (9) -- Processing cpuCyclesLimitExceeded (10) -- Processing dTEdCEInterfaceError (11) -- Communications datasetOrModemError (12) -- Equipment degradedSignal (13) -- Communications enclosureDoorOpen (14) -- Environmental equipmentMalfunction (15) -- Equipment excessiveVibration (16) -- Environmental fileError (17) -- Processing fireDetected (18) -- Environmental floodDetected (19) -- Environmental framingError (20) -- Communications heatingOrVentilationOrCoolingSystemProblem (21) -- Environmental humidityUnacceptable (22) -- Environmental inputDeviceError (23) -- Equipment inputOutputDeviceError (24) -- Equipment lANError (25) -- Communications leakDetected (26) -- Environmental localNodeTransmissionError (27) -- Communications lossOfFrame (28) -- Communications lossOfSignal (29) -- Communications materialSupplyExhausted (30) -- Environmental multiplexerProblem (31) -- Equipment outOfMemory (32) -- Processing outputDeviceError (33) -- Equipment performanceDegraded (34) -- Quality of service powerProblem (35) -- Equipment pressureUnacceptable (36) -- Environmental processorProblem (37) -- Equipment pumpFailure (38) -- Environmental queueSizeExceeded (39) -- Quality of service receiveFailure (40) -- Equipment receiverFailure (41) -- Equipment remoteNodeTransmissionError (42) -- Communications resourceAtOrNearingCapacity (43) -- Quality of service responseTimeExcessive (44) -- Quality of service retransmissionRateExcessive (45) -- Quality of service softwareProgramError (46) -- Processing softwareError (47) -- Processing softwareProgramAbnormallyTerminated (48) -- Processing storageCapacityProblem (49) -- Processing temperatureUnacceptable (50) -- Environmental thresholdCrossed (51) -- Quality of service timingProblem (52) -- Equipment toxicLeakDetected (53) -- Environmental transmitFailure (54) -- Equipment transmitterFailure (55) -- Equipment underlyingResourceUnavailable (56) -- Processing versionMismatch (57) -- Processing
Status: current Access: read-only
OBJECT-TYPE    
  AlarmProbableCause  

alarmPortAlias 1.3.6.1.4.1.30826.1.1.2.1.1.14
The Port Alias.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

alarmLogTable 1.3.6.1.4.1.30826.1.1.3.1
The active alarm list.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AlarmLogEntry

alarmLogEntry 1.3.6.1.4.1.30826.1.1.3.1.1
An entry in the alarm log table.
Status: current Access: not-accessible
OBJECT-TYPE    
  AlarmLogEntry  

alarmLogIndex 1.3.6.1.4.1.30826.1.1.3.1.1.1
An unique index assigned to each alarm.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 1..2147483647  

alarmLogUnit 1.3.6.1.4.1.30826.1.1.3.1.1.2
The alarming unit associated with this alarm. undefined(0), nmb(1), psu1(2), psu2(3), fan(4), system(5), slaveNmb(6), slavePsu1(7), slavePsu2(8), slaveFan(9).
Status: current Access: read-only
OBJECT-TYPE    
  UnitType  

alarmLogPort 1.3.6.1.4.1.30826.1.1.3.1.1.3
The alarming port associated with this alarm. 1-10 is Line Ports. 11 and higher is Client ports. For non port alarms this value is 0.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

alarmLogText 1.3.6.1.4.1.30826.1.1.3.1.1.4
The additional text for the alarm.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

alarmLogSeverity 1.3.6.1.4.1.30826.1.1.3.1.1.5
The severity of the alarm as defined in ITU-T X.733.
Status: current Access: read-only
OBJECT-TYPE    
  AlarmPerceivedSeverity  

alarmLogActivationTime 1.3.6.1.4.1.30826.1.1.3.1.1.6
The time when the alarm was created.
Status: current Access: read-only
OBJECT-TYPE    
  DateAndTime  

alarmLogCeaseTime 1.3.6.1.4.1.30826.1.1.3.1.1.7
The time when the alarm was ceased.
Status: current Access: read-only
OBJECT-TYPE    
  DateAndTime  

alarmLogSeqNumber 1.3.6.1.4.1.30826.1.1.3.1.1.8
The last sequence number used when issuing a notification for this alarm.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

alarmLogHostName 1.3.6.1.4.1.30826.1.1.3.1.1.9
The hostname.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

alarmLogPortName 1.3.6.1.4.1.30826.1.1.3.1.1.10
The Port Name.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

alarmLogPortType 1.3.6.1.4.1.30826.1.1.3.1.1.11
The Port Direction. rx(1), tx(2), biDi(3).
Status: current Access: read-only
OBJECT-TYPE    
  PortType  

alarmLogType 1.3.6.1.4.1.30826.1.1.3.1.1.12
The type of alarm as defined in ITU-T X.733 undefined (0), other (1), communicationsAlarm (2), qualityOfServiceAlarm (3), processingErrorAlarm (4), equipmentAlarm (5), environmental (6), integrityViolation (7), operationalViolation (8), physicalViolation(9), securityServiceOrMechanismViloation (10), timeDomainViolation (11)
Status: current Access: read-only
OBJECT-TYPE    
  AlarmNotificationType  

alarmLogCause 1.3.6.1.4.1.30826.1.1.3.1.1.13
The alarm probable cause as defined in ITU-T X.733. undefined (0) adapterError (1) -- Equipment applicationSubsystemFailure (2) -- Processing bandwidthReduced (3) -- Quality of service callEstablishmentError (4) -- Communications communicationsProtocolError (5) -- Communications communicationsSubsystemFailure (6) -- Communications configurationOrCustomizationError (7) -- Processing congestion (8) -- Quality of service corruptData (9) -- Processing cpuCyclesLimitExceeded (10) -- Processing dTEdCEInterfaceError (11) -- Communications datasetOrModemError (12) -- Equipment degradedSignal (13) -- Communications enclosureDoorOpen (14) -- Environmental equipmentMalfunction (15) -- Equipment excessiveVibration (16) -- Environmental fileError (17) -- Processing fireDetected (18) -- Environmental floodDetected (19) -- Environmental framingError (20) -- Communications heatingOrVentilationOrCoolingSystemProblem (21) -- Environmental humidityUnacceptable (22) -- Environmental inputDeviceError (23) -- Equipment inputOutputDeviceError (24) -- Equipment lANError (25) -- Communications leakDetected (26) -- Environmental localNodeTransmissionError (27) -- Communications lossOfFrame (28) -- Communications lossOfSignal (29) -- Communications materialSupplyExhausted (30) -- Environmental multiplexerProblem (31) -- Equipment outOfMemory (32) -- Processing outputDeviceError (33) -- Equipment performanceDegraded (34) -- Quality of service powerProblem (35) -- Equipment pressureUnacceptable (36) -- Environmental processorProblem (37) -- Equipment pumpFailure (38) -- Environmental queueSizeExceeded (39) -- Quality of service receiveFailure (40) -- Equipment receiverFailure (41) -- Equipment remoteNodeTransmissionError (42) -- Communications resourceAtOrNearingCapacity (43) -- Quality of service responseTimeExcessive (44) -- Quality of service retransmissionRateExcessive (45) -- Quality of service softwareProgramError (46) -- Processing softwareError (47) -- Processing softwareProgramAbnormallyTerminated (48) -- Processing storageCapacityProblem (49) -- Processing temperatureUnacceptable (50) -- Environmental thresholdCrossed (51) -- Quality of service timingProblem (52) -- Equipment toxicLeakDetected (53) -- Environmental transmitFailure (54) -- Equipment transmitterFailure (55) -- Equipment underlyingResourceUnavailable (56) -- Processing versionMismatch (57) -- Processing
Status: current Access: read-only
OBJECT-TYPE    
  AlarmProbableCause  

alarmNotifyPrefix 1.3.6.1.4.1.30826.1.1.4.0
OBJECT IDENTIFIER    

alarmNotificationCleared 1.3.6.1.4.1.30826.1.1.4.0.1
Sent when an alarm is cleared.
Status: current Access: read-only
NOTIFICATION-TYPE    

alarmNotificationWarning 1.3.6.1.4.1.30826.1.1.4.0.2
Sent when an alarm with warning severity is activated.
Status: current Access: read-only
NOTIFICATION-TYPE    

alarmNotificationMinor 1.3.6.1.4.1.30826.1.1.4.0.3
Sent when an alarm with minor severity is activated.
Status: current Access: read-only
NOTIFICATION-TYPE    

alarmNotificationMajor 1.3.6.1.4.1.30826.1.1.4.0.4
Sent when an alarm with major severity is activated..
Status: current Access: read-only
NOTIFICATION-TYPE    

alarmNotificationCritical 1.3.6.1.4.1.30826.1.1.4.0.5
Sent when an alarm with critical severity is activated.
Status: current Access: read-only
NOTIFICATION-TYPE    

smartAlarmGeneralGroupV1 1.3.6.1.4.1.30826.1.1.5.1.1
The general alarm objects V1.
Status: current Access: read-only
OBJECT-GROUP    

smartAlarmNotificationGroupV1 1.3.6.1.4.1.30826.1.1.5.1.2
The alarm notifications V1.
Status: current Access: read-only
NOTIFICATION-GROUP    

smartAlarmActiveTableGroupV1 1.3.6.1.4.1.30826.1.1.5.1.3
The active alarm table objects V1.
Status: current Access: read-only
OBJECT-GROUP    

smartAlarmLogTableGroupV1 1.3.6.1.4.1.30826.1.1.5.1.4
The alarm log table objects V1.
Status: current Access: read-only
OBJECT-GROUP    

smartAlarmBasicComplV1 1.3.6.1.4.1.30826.1.1.5.2.1
Basic implementation requirements for the alarm MIB V1.
Status: current Access: read-only
MODULE-COMPLIANCE