MOBANetClocksV2-MIB
File:
MOBANetClocksV2-MIB.mib (85963 bytes)
Imported modules
Imported symbols
Defined Types
MOBAAlarm64 |
|
The alarm list is an array of bytes. The first
byte defines the mask for the alarm bits 0..7.
The last byte defines the mask for the alarm
bits 56..63.
Every byte has the range 0 ... 255 (binary). |
TEXTUAL-CONVENTION |
|
|
|
|
OCTET STRING |
Size(8) |
|
MOBAFlags64 |
|
The flags are an array of bytes. The first
byte defines the mask for the status bits 0..7.
The last byte defines the mask for the status
bits 56..63.
Every byte has the range 0 ... 255 (binary). |
TEXTUAL-CONVENTION |
|
|
|
|
OCTET STRING |
Size(8) |
|
MOBANetworkName |
|
Fully qualified domain names or IP addresses in ASCII.
IPv4 xxx.xxx.xxx.xxx
IPV6 xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx
name string max 40 chars |
TEXTUAL-CONVENTION |
|
|
|
|
OCTET STRING |
Size(1..40) |
|
Defined Values
mbnscMIB |
1.3.6.1.4.1.13842.6.100 |
This mib definition is used for all MOBATime network slave clocks. |
MODULE-IDENTITY |
|
|
|
mobatime |
1.3.6.1.4.1.13842 |
OBJECT IDENTIFIER |
|
|
|
mbnscNet |
1.3.6.1.4.1.13842.6.2.1 |
OBJECT IDENTIFIER |
|
|
|
mbnscNetGen |
1.3.6.1.4.1.13842.6.2.1.1 |
OBJECT IDENTIFIER |
|
|
|
mbnscNetGenMAC |
1.3.6.1.4.1.13842.6.2.1.1.1 |
MAC-Address (xx xx xx xx xx xx) |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(6) |
|
mbnscNetGenIPMode |
1.3.6.1.4.1.13842.6.2.1.1.2 |
IP Mode:
0: IPv4 and IPv6
1: IPv4 only
2: IPv6 only |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
both(0), ipv4only(1), ipv6only(2) |
|
mbnscNetGenIPNameserver |
1.3.6.1.4.1.13842.6.2.1.1.3 |
IPv4 or IPv6 address (xxx.xxx.xxx.xxx or xxxx::xxxx:xxxx)
of the nameserver |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(1..40) |
|
mbnscNetGenSnmpMode |
1.3.6.1.4.1.13842.6.2.1.1.6 |
SNMP mode disabled
0: SNMP enabled (default)
1: SNMP disabled |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
0..1 |
|
mbnscNetGenMulticastMode |
1.3.6.1.4.1.13842.6.2.1.1.7 |
Multicast mode disabled
0: Multicast enabled (default)
1: Multicast disabled |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
0..1 |
|
mbnscNetGenCommMode |
1.3.6.1.4.1.13842.6.2.1.1.9 |
Communication / synchronisation mode
0=unicast
1=multicast
(only for digital clocks) |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
0..1 |
|
mbnscNetGenMCastGrpIP |
1.3.6.1.4.1.13842.6.2.1.1.10 |
IP network address (xxx.xxx.xxx.xxx) of the
multicast group IP e.g. 239.192.54.1
(only for digital clocks) |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
IpAddress |
|
|
mbnscNetGenConfigCmd |
1.3.6.1.4.1.13842.6.2.1.1.100 |
Network configuration changed command variable.
0: Not defined
1: SNMP has changed the configuration (possible restart of device)
2: SNMP requests to restore the old configuration |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
0..2 |
|
mbnscNetIPv4Addr |
1.3.6.1.4.1.13842.6.2.1.2.1 |
IP network address (xxx.xxx.xxx.xxx) of the
network slave clock |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
IpAddress |
|
|
mbnscNetIPv4Mask |
1.3.6.1.4.1.13842.6.2.1.2.2 |
IP subnet mask (xxx.xxx.xxx.xxx) |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
IpAddress |
|
|
mbnscNetIPv4Gateway |
1.3.6.1.4.1.13842.6.2.1.2.3 |
IP network address (xxx.xxx.xxx.xxx) for the gateway |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
IpAddress |
|
|
mbnscNetIPv4DHCPMode |
1.3.6.1.4.1.13842.6.2.1.2.4 |
DHCP mode
0: DHCP disabled
1: DHCP enabled (default) |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
0..1 |
|
mbnscNetIPv4ConfigCmd |
1.3.6.1.4.1.13842.6.2.1.2.100 |
Network configuration changed command variable.
0: Not defined
1: SNMP has changed the configuration (possible restart of device)
2: SNMP requests to restore the old configuration |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
0..2 |
|
mbnscNetIPv6AddrLocal |
1.3.6.1.4.1.13842.6.2.1.3.1 |
IP V6 link local network address (xxxx:xxxx::xxxx) |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(1..40) |
|
mbnscNetIPv6AddrAuto |
1.3.6.1.4.1.13842.6.2.1.3.2 |
IP V6 network address by autoconfig (xxxx:xxxx::xxxx) |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(1..40) |
|
mbnscNetIPv6AddrDHCP |
1.3.6.1.4.1.13842.6.2.1.3.3 |
IP V6 network address by DHCPv6 (xxxx:xxxx::xxxx) |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(1..40) |
|
mbnscNetIPv6AddrFix |
1.3.6.1.4.1.13842.6.2.1.3.4 |
IP V6 network address manual set (xxxx:xxxx::xxxx) |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
MOBANetworkName |
Size(40) |
|
mbnscNetIPv6Prefix |
1.3.6.1.4.1.13842.6.2.1.3.5 |
IPv6 subnet prefix for manual set IP address |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
0..128 |
|
mbnscNetIPv6Gateway |
1.3.6.1.4.1.13842.6.2.1.3.6 |
IP V6 network address of gateway (next hop) (xxxx:xxxx::xxxx) |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(1..40) |
|
mbnscNetIPv6Config |
1.3.6.1.4.1.13842.6.2.1.3.7 |
Mode of IPv6 adress configuration
0: auto and fixed
1: autoconfig only
2: DHCPv6 only
3: none |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
both(0), autoonly(1), dhcpv6only(2), none(3) |
|
mbnscNetIPv6ConfigCmd |
1.3.6.1.4.1.13842.6.2.1.3.100 |
Network configuration changed command variable.
0: Not defined
1: SNMP has changed the configuration (possible restart of device)
2: SNMP requests to restore the old configuration |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
0..2 |
|
mbnscTime |
1.3.6.1.4.1.13842.6.2.2 |
OBJECT IDENTIFIER |
|
|
|
mbnscTimeNTP1 |
1.3.6.1.4.1.13842.6.2.2.1 |
String with IPv4 or IPv6 address (192.168.3.4 or
FD03:2345:2345:2345::231) or DNS name to
get NTP time information. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(1..40) |
|
mbnscTimeNTP2 |
1.3.6.1.4.1.13842.6.2.2.2 |
String with IPv4 or IPv6 address (192.168.3.4 or
FD03:2345:2345:2345::231) or DNS name to
get NTP time information. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(1..40) |
|
mbnscTimeNTP3 |
1.3.6.1.4.1.13842.6.2.2.3 |
String with IPv4 or IPv6 address (192.168.3.4 or
FD03:2345:2345:2345::231) or DNS name to
get NTP time information. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(1..40) |
|
mbnscTimeNTP4 |
1.3.6.1.4.1.13842.6.2.2.4 |
String with IPv4 or IPv6 address (192.168.3.4 or
FD03:2345:2345:2345::231) or DNS name to
get NTP time information. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(1..40) |
|
mbnscTimeNTPcurrent |
1.3.6.1.4.1.13842.6.2.2.5 |
IPv4 or IPv6 address of current NTP server |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(1..40) |
|
mbnscTimeDeviceTime |
1.3.6.1.4.1.13842.6.2.2.7 |
Actual device time (UTC).
Seconds since 1.1.1970 00:00:00 |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
mbnscTimeLocOffset |
1.3.6.1.4.1.13842.6.2.2.8 |
Offset to localt time in minutes
(-720..720) |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
-720..720 |
|
mbnscTimeLastReception |
1.3.6.1.4.1.13842.6.2.2.9 |
Last received time (UTC).
Seconds since 1.1.1970 00:00:00 |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
mbnscTimeConfigCmd |
1.3.6.1.4.1.13842.6.2.2.100 |
Time configuration changed command variable.
0: Not defined
1: SNMP has changed the configuration (possible restart of device)
2: SNMP requests to restore the old configuration |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
0..2 |
|
mbnscTimeZoneVersion |
1.3.6.1.4.1.13842.6.2.3.1 |
Actual version internal time zone table |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
1..255 |
|
mbnscTimeZoneNumber |
1.3.6.1.4.1.13842.6.2.3.2 |
Time zone
0: UTC
1..64: See user manual, time zone table
65..128: user defined time zone
129..143: time zone server 1..15
254: automatic time zone - e.g. UTC
255: internal user defined time zone
(SET only used for digital clocks) |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..255 |
|
mbnscTimeZoneEntry1 |
1.3.6.1.4.1.13842.6.2.3.3 |
Time Zone entry -> see special definition |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(18) |
|
mbnscTimeZoneEntry2 |
1.3.6.1.4.1.13842.6.2.3.4 |
Time Zone entry -> see special definition |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(18) |
|
mbnscTimeZoneEntry3 |
1.3.6.1.4.1.13842.6.2.3.5 |
Time Zone entry -> see special definition |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(18) |
|
mbnscTimeZoneEntry4 |
1.3.6.1.4.1.13842.6.2.3.6 |
Time Zone entry -> see special definition |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(18) |
|
mbnscTimeZoneEntry5 |
1.3.6.1.4.1.13842.6.2.3.7 |
Time Zone entry -> see special definition |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(18) |
|
mbnscTimeZoneEntry6 |
1.3.6.1.4.1.13842.6.2.3.8 |
Time Zone entry -> see special definition |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(18) |
|
mbnscTimeZoneEntry7 |
1.3.6.1.4.1.13842.6.2.3.9 |
Time Zone entry -> see special definition |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(18) |
|
mbnscTimeZoneConfigCmd |
1.3.6.1.4.1.13842.6.2.3.100 |
Time zone configuration changed command variable.
0: Not defined
1: SNMP has changed the configuration (possible restart of device)
2: SNMP requests to restore the old configuration |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
0..2 |
|
mbnscMode |
1.3.6.1.4.1.13842.6.2.4 |
OBJECT IDENTIFIER |
|
|
|
mbnscModeSwitchInfo |
1.3.6.1.4.1.13842.6.2.4.1 |
Current switch settings
(only analogue movements) |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
mbnscModeDisplayAlternate |
1.3.6.1.4.1.13842.6.2.4.4 |
Display alternating mode for digital clocks
1: time continuously
2: date cont.
3: temperature cont. (sequence 6 sec. time, 3 sec. date for ECO-DC)
4: stopwatch cont. (only DC clock)
5: sequence 6 sec. time, 3 sec. date (only DC clock)
6: sequence 8 sec. time, 3 sec. date, 3 sec. temperature (only DC clock) |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..2) |
|
mbnscModeNTP |
1.3.6.1.4.1.13842.6.2.4.5 |
NTP synchronisation mode for digital clocks |
Status: obsolete |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..2) |
|
mbnscModeIRlock |
1.3.6.1.4.1.13842.6.2.4.6 |
IR autolock time for digital clocks (only DC clock)
1..60, U (autolock off) |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..2) |
|
mbnscModeTimeDispZeros |
1.3.6.1.4.1.13842.6.2.4.7 |
Leading zeros time display for digital clocks (only DC clock)
1: time with leading zero
2: time without leading zero |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..2) |
|
mbnscModeDateDispZeros |
1.3.6.1.4.1.13842.6.2.4.8 |
Leading zeros date display for digital clocks (only DC clock)
1: date with leading zero
2: date without leading zero |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..2) |
|
mbnscModeTempUnit |
1.3.6.1.4.1.13842.6.2.4.9 |
Temperature unit for digital clocks (only DC clock)
C: Celsius
F: Fahrenheit |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..2) |
|
mbnscModeClockOpMode |
1.3.6.1.4.1.13842.6.2.4.10 |
Operation mode for digital clocks (only DC clock)
0: normal mode
1: special mode 1
2: special mode 2 |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..2) |
|
mbnscModeNWParam |
1.3.6.1.4.1.13842.6.2.4.11 |
Network parameter setting mode for digital clocks |
Status: obsolete |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..2) |
|
mbnscModeDispDerating |
1.3.6.1.4.1.13842.6.2.4.12 |
Display current deration setting for digital clocks
(see service menu definition) |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..2) |
|
mbnscModeLightCorr |
1.3.6.1.4.1.13842.6.2.4.13 |
Light measurement correction for digital clocks
(see service menu definition) |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..2) |
|
mbnscSensorsTempActivation |
1.3.6.1.4.1.13842.6.2.4.30.1.1 |
Temperature sensor activation
1: DS18B20
3: TME (only sensor 1)
4: TME (Sensors 1 and 2) |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..2) |
|
mbnscSensorsTemp1IPAddr |
1.3.6.1.4.1.13842.6.2.4.30.1.2 |
IP network address (xxx.xxx.xxx.xxx) of the
sensor 1
(SET only used for digital clocks) |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
IpAddress |
|
|
mbnscSensorsTemp2IPAddr |
1.3.6.1.4.1.13842.6.2.4.30.1.3 |
IP network address (xxx.xxx.xxx.xxx) of the
sensor 2
(SET only used for digital clocks) |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
IpAddress |
|
|
mbnscSensorsConfigCmd |
1.3.6.1.4.1.13842.6.2.4.30.1.100 |
Mode configuration changed command variable.
0: Not defined
1: SNMP has changed the configuration (possible restart of device)
2: SNMP requests to restore the old configuration |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
0..2 |
|
mbnscDA |
1.3.6.1.4.1.13842.6.2.4.30.2 |
OBJECT IDENTIFIER |
|
|
|
mbnscDASecondCircleDisplay |
1.3.6.1.4.1.13842.6.2.4.30.2.1 |
The second circle display mode
1: Accumulating ring of seconds marker
2: Take actual second from full shining circle step by step
3: Full shining circle, actual second off
4: Three shining seconds, the first is showing actual second
5: Two shining seconds, the first is showing actual second |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..2) |
|
mbnscDAConfigCmd |
1.3.6.1.4.1.13842.6.2.4.30.2.100 |
Mode configuration changed command variable.
0: Not defined
1: SNMP has changed the configuration (possible restart of device)
2: SNMP requests to restore the old configuration |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
0..2 |
|
mbnscDK |
1.3.6.1.4.1.13842.6.2.4.30.3 |
OBJECT IDENTIFIER |
|
|
|
mbnscDKFirstLanguage |
1.3.6.1.4.1.13842.6.2.4.30.3.1 |
First language selection
1: Czech
2: Slovak
3: English
4: German
5: ...
(see manual for full language list) |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..2) |
|
mbnscDKSecondLanguage |
1.3.6.1.4.1.13842.6.2.4.30.3.2 |
Second language selection
1: Czech
2: Slovak
3: English
4: German
5: ...
(see manual for full language list) |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..2) |
|
mbnscDKThirdLanguage |
1.3.6.1.4.1.13842.6.2.4.30.3.3 |
Third language selection
1: Czech
2: Slovak
3: English
4: German
5: ...
(see manual for full language list) |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..2) |
|
mbnscDKTempUnitSecondLang |
1.3.6.1.4.1.13842.6.2.4.30.3.4 |
Temperature units for second selected language
C: Celsius
F: Fahrenheit |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..2) |
|
mbnscDKTempUnitThirdLang |
1.3.6.1.4.1.13842.6.2.4.30.3.5 |
Temperature units for third selected language
C: Celsius
F: Fahrenheit |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..2) |
|
mbnscDKAutoLangSwitchOver |
1.3.6.1.4.1.13842.6.2.4.30.3.6 |
Language switch mode for automatic language
switching over in one display alternating cycle
A: all languages
S: simple language |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..2) |
|
mbnscDKNumOfCharsForWeekday |
1.3.6.1.4.1.13842.6.2.4.30.3.7 |
Number of characters used for weekday names
2: two characters
3: three characters |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..2) |
|
mbnscDKWorldTimeZone1 |
1.3.6.1.4.1.13842.6.2.4.30.3.13 |
Index of time zone for world time zone 1
0: UTC
1..64: See user manual, time zone table
65..128: user defined time zone
129..143: time zone server 1..15
255: none
(SET only used for digital clocks) |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..255 |
|
mbnscDKWorldTimeZone2 |
1.3.6.1.4.1.13842.6.2.4.30.3.15 |
Index of time zone for world time zone 2
0: UTC
1..64: See user manual, time zone table
65..128: user defined time zone
129..143: time zone server 1..15
255: none
(SET only used for digital clocks) |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..255 |
|
mbnscDKWorldTimeZone3 |
1.3.6.1.4.1.13842.6.2.4.30.3.17 |
Index of time zone for world time zone 3
0: UTC
1..64: See user manual, time zone table
65..128: user defined time zone
129..143: time zone server 1..15
255: none
(SET only used for digital clocks) |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..255 |
|
mbnscDKWorldTimeZone4 |
1.3.6.1.4.1.13842.6.2.4.30.3.19 |
Index of time zone for world time zone 4
0: UTC
1..64: See user manual, time zone table
65..128: user defined time zone
129..143: time zone server 1..15
255: none
(SET only used for digital clocks) |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..255 |
|
mbnscDKWorldTimeZone5 |
1.3.6.1.4.1.13842.6.2.4.30.3.21 |
Index of time zone for world time zone 5
0: UTC
1..64: See user manual, time zone table
65..128: user defined time zone
129..143: time zone server 1..15
255: none
(SET only used for digital clocks) |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
0..255 |
|
mbnscDKAutoTimeZoneSwitchOver |
1.3.6.1.4.1.13842.6.2.4.30.3.23 |
World time switch mode for automatic time zone
switching over in one display alternating cycle
A: all world time zones
S: simple world time zone |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..2) |
|
mbnscDKConfigCmd |
1.3.6.1.4.1.13842.6.2.4.30.3.100 |
Mode configuration changed command variable.
0: Not defined
1: SNMP has changed the configuration (possible restart of device)
2: SNMP requests to restore the old configuration |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
0..2 |
|
mbnscModeConfigCmd |
1.3.6.1.4.1.13842.6.2.4.100 |
Mode configuration changed command variable.
0: Not defined
1: SNMP has changed the configuration (possible restart of device)
2: SNMP requests to restore the old configuration |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
0..2 |
|
mbnscNMI |
1.3.6.1.4.1.13842.6.2.4.40.1 |
OBJECT IDENTIFIER |
|
|
|
mbnscNMIDCFCurrentLoop |
1.3.6.1.4.1.13842.6.2.4.40.1.1 |
Operation mode of the DCF77 current loop.
0: OFF
1: ON |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
off(0), on(1) |
|
mbnscNMILineDriver |
1.3.6.1.4.1.13842.6.2.4.40.1.2 |
Operation mode of the line driver.
0: OFF
1: MOBALine
2: Active DCF |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
off(0), mobaline(1), activdcf(2) |
|
mbnscNMIMOBALineMode |
1.3.6.1.4.1.13842.6.2.4.40.1.3 |
Operation mode of MOBALine.
0: normal operation
1: 12:00 mode, sideclocks shows 12:00 position
2: clock-id mode, sideclocks shows their ids if configured |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
normal(0), command12h(1), clockidcommand(2) |
|
mbnscNMIMOBALineMinuteHandMode |
1.3.6.1.4.1.13842.6.2.4.40.1.4 |
Minute hand mode operation of MOBALine.
0: minute step mode
1: half minute step mode
2: continuous mode |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
minutestep(0), halfminutestep(1), continuous(2) |
|
mbnscNMIActiveDCFMode |
1.3.6.1.4.1.13842.6.2.4.40.1.5 |
Operation mode of Active DCF.
1: Mode 1
2: Mode 2
3: Mode 3
4: Mode 4
5: Mode 5
6: Mode 6 |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
mode1(1), mode2(2), mode3(3), mode4(4), mode5(5), mode6(6) |
|
mbnscNMIConfigCmd |
1.3.6.1.4.1.13842.6.2.4.40.1.100 |
General configuration changed command variable.
0: Not defined
1: SNMP has changed the configuration (possible restart of device)
2: SNMP requests to restore the old configuration |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
0..2 |
|
mbnscNMISideClock1 |
1.3.6.1.4.1.13842.6.2.4.40.1.20.1 |
State of side clock 1
0: Clock not configured
3: Clock OK
5: Clock error |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
notconfigured(0), clockok(3), clockerror(5) |
|
mbnscNMISideClock2 |
1.3.6.1.4.1.13842.6.2.4.40.1.20.2 |
State of side clock 2
0: Clock not configured
3: Clock OK
5: Clock error |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
notconfigured(0), clockok(3), clockerror(5) |
|
mbnscNMISideClock3 |
1.3.6.1.4.1.13842.6.2.4.40.1.20.3 |
State of side clock 3
0: Clock not configured
3: Clock OK
5: Clock error |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
notconfigured(0), clockok(3), clockerror(5) |
|
mbnscNMISideClock4 |
1.3.6.1.4.1.13842.6.2.4.40.1.20.4 |
State of side clock 4
0: Clock not configured
3: Clock OK
5: Clock error |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
notconfigured(0), clockok(3), clockerror(5) |
|
mbnscNMISideClock5 |
1.3.6.1.4.1.13842.6.2.4.40.1.20.5 |
State of side clock 5
0: Clock not configured
3: Clock OK
5: Clock error |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
notconfigured(0), clockok(3), clockerror(5) |
|
mbnscNMISideClock6 |
1.3.6.1.4.1.13842.6.2.4.40.1.20.6 |
State of side clock 6
0: Clock not configured
3: Clock OK
5: Clock error |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
notconfigured(0), clockok(3), clockerror(5) |
|
mbnscNMISideClock7 |
1.3.6.1.4.1.13842.6.2.4.40.1.20.7 |
State of side clock 7
0: Clock not configured
3: Clock OK
5: Clock error |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
notconfigured(0), clockok(3), clockerror(5) |
|
mbnscNMISideClock8 |
1.3.6.1.4.1.13842.6.2.4.40.1.20.8 |
State of side clock 8
0: Clock not configured
3: Clock OK
5: Clock error |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
notconfigured(0), clockok(3), clockerror(5) |
|
mbnscNMISideClock9 |
1.3.6.1.4.1.13842.6.2.4.40.1.20.9 |
State of side clock 9
0: Clock not configured
3: Clock OK
5: Clock error |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
notconfigured(0), clockok(3), clockerror(5) |
|
mbnscNMISideClock10 |
1.3.6.1.4.1.13842.6.2.4.40.1.20.10 |
State of side clock 10
0: Clock not configured
3: Clock OK
5: Clock error |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
notconfigured(0), clockok(3), clockerror(5) |
|
mbnscNMISideClock11 |
1.3.6.1.4.1.13842.6.2.4.40.1.20.11 |
State of side clock 11
0: Clock not configured
3: Clock OK
5: Clock error |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
notconfigured(0), clockok(3), clockerror(5) |
|
mbnscNMISideClock12 |
1.3.6.1.4.1.13842.6.2.4.40.1.20.12 |
State of side clock 12
0: Clock not configured
3: Clock OK
5: Clock error |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
notconfigured(0), clockok(3), clockerror(5) |
|
mbnscGeneralType |
1.3.6.1.4.1.13842.6.2.5.1 |
Network slave clock type
1 Network Clock Interface NCI
2 Wireless Time Distribution WTD 868-T
3 NTP movement SEN 00
4 NTP movement NBU 190
5 Digital Clock ECO-DC
6 Digital Clock DC3
7 NTP movement SEN 40
8 NTP movement SAN 40
9 NTP digital clock DA
10 NTP calendar digital clock DK2
11 Network MOBALine Interface NMI
12 NTP clock TREND
13 NTP clock TREND double sided
14 NTP in- and outdoor digital clock DSC |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
1..14 |
|
mbnscGeneralStatus |
1.3.6.1.4.1.13842.6.2.5.5 |
Network slave clock status (64bit). Internal state of the
network slave clock. Used for maintenance only.
Bit 00 : time ok
Bit 01 : 12h position
Bit 02 : Reserved
Bit 03 : Reserved
Bit 04 : Reserved
Bit 05 : Reserved
Bit 06 : Reserved
Bit 07 : Reserved
Bit 08 : Reserved
Bit 09 : Reserved
Bit 10 : Reserved
Bit 11 : Reserved
Bit 12 : Reserved
Bit 13 : Reserved
Bit 14 : Reserved
Bit 15 : Reserved
Bit 16 : Reserved
Bit 17 : Reserved
Bit 18 : Reserved
Bit 19 : Reserved
Bit 20 : Reserved
Bit 21 : Reserved
Bit 22 : Reserved
Bit 23 : Reserved
Bit 24 : Reserved
Bit 25 : Reserved
Bit 26 : Reserved
Bit 27 : Reserved
Bit 28 : Reserved
Bit 29 : Reserved
Bit 30 : Reserved
Bit 31 : Reserved
Bit32..63 not used |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
MOBAFlags64 |
|
|
mbnscGeneralAlarms |
1.3.6.1.4.1.13842.6.2.5.6 |
Alarm state of the network slave clock
Bit00=Synchronization
Bit01=Power supply
Bit02=Slave (cascade)
Bit03=Illumination
Bit04=Hands position (sec)
Bit05=Hands position (m/h)
Bit06=Restart
Bit07=CommError
Bit08=Time zone
Bit09=Reserved
Bit10=Reserved
Bit11=Reserved
Bit12=Reserved
Bit13=Reserved
Bit14=Reserved
Bit15=Reserved
Bit16=Reserved
Bit17=Reserved
Bit18=Reserved
Bit19=Reserved
Bit20=Reserved
Bit21=Reserved
Bit22=Reserved
Bit23=Reserved
Bit24=Reserved
Bit25=Reserved
Bit26=Reserved
Bit27=Reserved
Bit28=Reserved
Bit29=Reserved
Bit30=Reserved
Bit31=Reserved
Bit32..Bit63=Device type specific error |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
MOBAAlarm64 |
|
|
mbnscGeneralSlaveInfo1 |
1.3.6.1.4.1.13842.6.2.5.7 |
Info from slave 1
Byte 0..5 MAC
Byte 6..11 Slave local time
Byte 12..17 SW-number
Byte 18..21 SW-version
Byte 22 state
Byte 23 reserved
Byte 24 error
Byte 25 reserved |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(26) |
|
mbnscGeneralSlaveInfo2 |
1.3.6.1.4.1.13842.6.2.5.8 |
Info from slave 2
Byte 0..5 MAC
Byte 6..11 Slave local time
Byte 12..17 SW-number
Byte 18..21 SW-version
Byte 22 state
Byte 23 reserved
Byte 24 error
Byte 25 reserved |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(26) |
|
mbnscGeneralSlaveInfo3 |
1.3.6.1.4.1.13842.6.2.5.9 |
Info from slave 3
Byte 0..5 MAC
Byte 6..11 Slave local time
Byte 12..17 SW-number
Byte 18..21 SW-version
Byte 22 state
Byte 23 reserved
Byte 24 error
Byte 25 reserved |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(26) |
|
mbnscGeneralConfigCmd |
1.3.6.1.4.1.13842.6.2.5.100 |
General configuration changed command variable.
0: Not defined
1: SNMP has changed the configuration (possible restart of device)
2: SNMP requests to restore the old configuration |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
0..2 |
|
mbnscSNMPManager1 |
1.3.6.1.4.1.13842.6.2.6.1 |
String with IPv4 or IPv6 address (e.g 192.168.3.4
or FD03:2345:2345:2345::231) of the SNMP manager 1 |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(1..40) |
|
mbnscSNMPManager2 |
1.3.6.1.4.1.13842.6.2.6.2 |
String with IPv4 or IPv6 address (e.g 192.168.3.4
or FD03:2345:2345:2345::231) of the SNMP manager 2 |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(1..40) |
|
mbnscSNMPTrapAliveMsgInterval |
1.3.6.1.4.1.13842.6.2.6.3 |
Time interval to send the alive message to the
trap listener stations.
0: Alive message disabled >0: Alive message enabled
Range: 1 ... 1440 minutes |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
0 | 1..1440 |
|
mbnscSNMPConfigCmd |
1.3.6.1.4.1.13842.6.2.6.100 |
SNMP / supervision services configuration changed command variable.
0: Not defined
1: SNMP has changed the configuration (possible restart of device)
2: SNMP requests to restore the old configuration |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
0..2 |
|
mbnscCommand12Pos |
1.3.6.1.4.1.13842.6.2.7.1 |
Mode of the analogue clock:
0=run, 1=12h position |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
0..1 |
|
mbnscCommandFirmwUpd |
1.3.6.1.4.1.13842.6.2.7.4 |
Command to start FW update |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(10) |
|
mbnscCommandConfigCmd |
1.3.6.1.4.1.13842.6.2.7.100 |
SNMP / supervision services configuration changed command variable.
0: Not defined
1: SNMP has changed the configuration (possible restart of device)
2: SNMP requests to restore the old configuration |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
0..2 |
|
mbnscTrapAlMsgErrorNr |
1.3.6.1.4.1.13842.6.2.9.1.1 |
Error number of the trap message. |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
0..63 |
|
mbnscTrapAlMsgErrorTime |
1.3.6.1.4.1.13842.6.2.9.1.3 |
Error time of the trap message.
Seconds since 1.1.1970 00:00:00 |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
mbnscTraps |
1.3.6.1.4.1.13842.6.2.10 |
OBJECT IDENTIFIER |
|
|
|
mbnscTrapsAlarm |
1.3.6.1.4.1.13842.6.2.10.1 |
Alarm trap with attached (binded variables) alarm
information.
mbnscTrapAlMsgErrorNr, mbnscTrapAlMsgErrorState,
mbnscTrapAlMsgErrorTime |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
mbnscTrapsAlive |
1.3.6.1.4.1.13842.6.2.10.2 |
Device alive trap. Will be send in the configured
interval. Attached are the variables mbnscGeneralStatus
and mbnscGeneralAlarms. |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
mbnscMIBCompliances |
1.3.6.1.4.1.13842.6.100.1.1 |
Please replace this text with your description. |
Status: current |
Access: accessible-for-notify |
MODULE-COMPLIANCE |
|
|
|
mbnscAllNotifications |
1.3.6.1.4.1.13842.6.100.2.1 |
This automatically created notification group
contains all notifications that do not belong
to any other NOTIFICATION-GROUP |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-GROUP |
|
|
|
mbnscGrpNBU190 |
1.3.6.1.4.1.13842.6.100.2.2 |
All parameters used for NBU 190 movement |
Status: current |
Access: accessible-for-notify |
OBJECT-GROUP |
|
|
|
mbnscGrpSEN40 |
1.3.6.1.4.1.13842.6.100.2.3 |
All parameters used for SEN 40 movement |
Status: current |
Access: accessible-for-notify |
OBJECT-GROUP |
|
|
|
mbnscGrpDC |
1.3.6.1.4.1.13842.6.100.2.4 |
All parameters used for DC digital clock |
Status: current |
Access: accessible-for-notify |
OBJECT-GROUP |
|
|
|
mbnscGrpECODC |
1.3.6.1.4.1.13842.6.100.2.5 |
All parameters used for ECO DC digital clock |
Status: current |
Access: accessible-for-notify |
OBJECT-GROUP |
|
|
|
mbnscGrpDA |
1.3.6.1.4.1.13842.6.100.2.6 |
All parameters used for DA digital clock |
Status: current |
Access: accessible-for-notify |
OBJECT-GROUP |
|
|
|
mbnscGrpDK |
1.3.6.1.4.1.13842.6.100.2.7 |
All parameters used for DK digital clock |
Status: current |
Access: accessible-for-notify |
OBJECT-GROUP |
|
|
|
mbnscGrpNMI |
1.3.6.1.4.1.13842.6.100.2.8 |
All parameters used for Network-MOBALine-Interface NMI |
Status: current |
Access: accessible-for-notify |
OBJECT-GROUP |
|
|
|
mbnscGrpNotUsedParameters |
1.3.6.1.4.1.13842.6.100.2.100 |
All parameters not used in oother groups |
Status: current |
Access: accessible-for-notify |
OBJECT-GROUP |
|
|
|