MOBANetClocksV2-MIB

File: MOBANetClocksV2-MIB.mib (85963 bytes)

Imported modules

SNMPv2-SMI SNMPv2-CONF SNMPv2-TC

Imported symbols

Integer32 OBJECT-TYPE MODULE-IDENTITY
enterprises Unsigned32 NOTIFICATION-TYPE
TimeTicks IpAddress OBJECT-GROUP
NOTIFICATION-GROUP MODULE-COMPLIANCE DisplayString
TEXTUAL-CONVENTION

Defined Types

MOBAAlarm64  
The alarm list is an array of bytes. The first byte defines the mask for the alarm bits 0..7. The last byte defines the mask for the alarm bits 56..63. Every byte has the range 0 ... 255 (binary).
TEXTUAL-CONVENTION    
  OCTET STRING Size(8)  

MOBAFlags64  
The flags are an array of bytes. The first byte defines the mask for the status bits 0..7. The last byte defines the mask for the status bits 56..63. Every byte has the range 0 ... 255 (binary).
TEXTUAL-CONVENTION    
  OCTET STRING Size(8)  

MOBANetworkName  
Fully qualified domain names or IP addresses in ASCII. IPv4 xxx.xxx.xxx.xxx IPV6 xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx name string max 40 chars
TEXTUAL-CONVENTION    
  OCTET STRING Size(1..40)  

Defined Values

mbnscMIB 1.3.6.1.4.1.13842.6.100
This mib definition is used for all MOBATime network slave clocks.
MODULE-IDENTITY    

mobatime 1.3.6.1.4.1.13842
OBJECT IDENTIFIER    

mobaNetClocks 1.3.6.1.4.1.13842.6
OBJECT IDENTIFIER    

mobaNetClocksV2 1.3.6.1.4.1.13842.6.2
OBJECT IDENTIFIER    

mbnscNet 1.3.6.1.4.1.13842.6.2.1
OBJECT IDENTIFIER    

mbnscNetGen 1.3.6.1.4.1.13842.6.2.1.1
OBJECT IDENTIFIER    

mbnscNetGenMAC 1.3.6.1.4.1.13842.6.2.1.1.1
MAC-Address (xx xx xx xx xx xx)
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6)  

mbnscNetGenIPMode 1.3.6.1.4.1.13842.6.2.1.1.2
IP Mode: 0: IPv4 and IPv6 1: IPv4 only 2: IPv6 only
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER both(0), ipv4only(1), ipv6only(2)  

mbnscNetGenIPNameserver 1.3.6.1.4.1.13842.6.2.1.1.3
IPv4 or IPv6 address (xxx.xxx.xxx.xxx or xxxx::xxxx:xxxx) of the nameserver
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..40)  

mbnscNetGenTZClientPort 1.3.6.1.4.1.13842.6.2.1.1.4
Timezone client port. Default 65534
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 1..65535  

mbnscNetGenConfigPort 1.3.6.1.4.1.13842.6.2.1.1.5
Configuration port. Default 65532
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 1..65535  

mbnscNetGenSnmpMode 1.3.6.1.4.1.13842.6.2.1.1.6
SNMP mode disabled 0: SNMP enabled (default) 1: SNMP disabled
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..1  

mbnscNetGenMulticastMode 1.3.6.1.4.1.13842.6.2.1.1.7
Multicast mode disabled 0: Multicast enabled (default) 1: Multicast disabled
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..1  

mbnscNetGenHostname 1.3.6.1.4.1.13842.6.2.1.1.8
Host name of the device
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..20)  

mbnscNetGenCommMode 1.3.6.1.4.1.13842.6.2.1.1.9
Communication / synchronisation mode 0=unicast 1=multicast (only for digital clocks)
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..1  

mbnscNetGenMCastGrpIP 1.3.6.1.4.1.13842.6.2.1.1.10
IP network address (xxx.xxx.xxx.xxx) of the multicast group IP e.g. 239.192.54.1 (only for digital clocks)
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

mbnscNetGenConfigCmd 1.3.6.1.4.1.13842.6.2.1.1.100
Network configuration changed command variable. 0: Not defined 1: SNMP has changed the configuration (possible restart of device) 2: SNMP requests to restore the old configuration
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..2  

mbnscNetGenConfigChangedTime 1.3.6.1.4.1.13842.6.2.1.1.101
Time of the last configuration change.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

mbnscNetIPv4 1.3.6.1.4.1.13842.6.2.1.2
OBJECT IDENTIFIER    

mbnscNetIPv4Addr 1.3.6.1.4.1.13842.6.2.1.2.1
IP network address (xxx.xxx.xxx.xxx) of the network slave clock
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

mbnscNetIPv4Mask 1.3.6.1.4.1.13842.6.2.1.2.2
IP subnet mask (xxx.xxx.xxx.xxx)
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

mbnscNetIPv4Gateway 1.3.6.1.4.1.13842.6.2.1.2.3
IP network address (xxx.xxx.xxx.xxx) for the gateway
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

mbnscNetIPv4DHCPMode 1.3.6.1.4.1.13842.6.2.1.2.4
DHCP mode 0: DHCP disabled 1: DHCP enabled (default)
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..1  

mbnscNetIPv4ConfigCmd 1.3.6.1.4.1.13842.6.2.1.2.100
Network configuration changed command variable. 0: Not defined 1: SNMP has changed the configuration (possible restart of device) 2: SNMP requests to restore the old configuration
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..2  

mbnscNetIPv4ConfigChangedTime 1.3.6.1.4.1.13842.6.2.1.2.101
Time of the last configuration change.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

mbnscNetIPv6 1.3.6.1.4.1.13842.6.2.1.3
OBJECT IDENTIFIER    

mbnscNetIPv6AddrLocal 1.3.6.1.4.1.13842.6.2.1.3.1
IP V6 link local network address (xxxx:xxxx::xxxx)
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..40)  

mbnscNetIPv6AddrAuto 1.3.6.1.4.1.13842.6.2.1.3.2
IP V6 network address by autoconfig (xxxx:xxxx::xxxx)
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..40)  

mbnscNetIPv6AddrDHCP 1.3.6.1.4.1.13842.6.2.1.3.3
IP V6 network address by DHCPv6 (xxxx:xxxx::xxxx)
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..40)  

mbnscNetIPv6AddrFix 1.3.6.1.4.1.13842.6.2.1.3.4
IP V6 network address manual set (xxxx:xxxx::xxxx)
Status: current Access: read-write
OBJECT-TYPE    
  MOBANetworkName Size(40)  

mbnscNetIPv6Prefix 1.3.6.1.4.1.13842.6.2.1.3.5
IPv6 subnet prefix for manual set IP address
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..128  

mbnscNetIPv6Gateway 1.3.6.1.4.1.13842.6.2.1.3.6
IP V6 network address of gateway (next hop) (xxxx:xxxx::xxxx)
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..40)  

mbnscNetIPv6Config 1.3.6.1.4.1.13842.6.2.1.3.7
Mode of IPv6 adress configuration 0: auto and fixed 1: autoconfig only 2: DHCPv6 only 3: none
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER both(0), autoonly(1), dhcpv6only(2), none(3)  

mbnscNetIPv6ConfigCmd 1.3.6.1.4.1.13842.6.2.1.3.100
Network configuration changed command variable. 0: Not defined 1: SNMP has changed the configuration (possible restart of device) 2: SNMP requests to restore the old configuration
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..2  

mbnscNetIPv6ConfigChangedTime 1.3.6.1.4.1.13842.6.2.1.3.101
Time of the last configuration change.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

mbnscTime 1.3.6.1.4.1.13842.6.2.2
OBJECT IDENTIFIER    

mbnscTimeNTP1 1.3.6.1.4.1.13842.6.2.2.1
String with IPv4 or IPv6 address (192.168.3.4 or FD03:2345:2345:2345::231) or DNS name to get NTP time information.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..40)  

mbnscTimeNTP2 1.3.6.1.4.1.13842.6.2.2.2
String with IPv4 or IPv6 address (192.168.3.4 or FD03:2345:2345:2345::231) or DNS name to get NTP time information.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..40)  

mbnscTimeNTP3 1.3.6.1.4.1.13842.6.2.2.3
String with IPv4 or IPv6 address (192.168.3.4 or FD03:2345:2345:2345::231) or DNS name to get NTP time information.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..40)  

mbnscTimeNTP4 1.3.6.1.4.1.13842.6.2.2.4
String with IPv4 or IPv6 address (192.168.3.4 or FD03:2345:2345:2345::231) or DNS name to get NTP time information.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..40)  

mbnscTimeNTPcurrent 1.3.6.1.4.1.13842.6.2.2.5
IPv4 or IPv6 address of current NTP server
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..40)  

mbnscTimeNTPpollIntervall 1.3.6.1.4.1.13842.6.2.2.6
NTP request intervall 10..999sec
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 10..999  

mbnscTimeDeviceTime 1.3.6.1.4.1.13842.6.2.2.7
Actual device time (UTC). Seconds since 1.1.1970 00:00:00
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

mbnscTimeLocOffset 1.3.6.1.4.1.13842.6.2.2.8
Offset to localt time in minutes (-720..720)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -720..720  

mbnscTimeLastReception 1.3.6.1.4.1.13842.6.2.2.9
Last received time (UTC). Seconds since 1.1.1970 00:00:00
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

mbnscTimeConfigCmd 1.3.6.1.4.1.13842.6.2.2.100
Time configuration changed command variable. 0: Not defined 1: SNMP has changed the configuration (possible restart of device) 2: SNMP requests to restore the old configuration
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..2  

mbnscTimeConfigChangedTime 1.3.6.1.4.1.13842.6.2.2.101
Time of the last configuration change.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

mbnscTimeZone 1.3.6.1.4.1.13842.6.2.3
OBJECT IDENTIFIER    

mbnscTimeZoneVersion 1.3.6.1.4.1.13842.6.2.3.1
Actual version internal time zone table
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

mbnscTimeZoneNumber 1.3.6.1.4.1.13842.6.2.3.2
Time zone 0: UTC 1..64: See user manual, time zone table 65..128: user defined time zone 129..143: time zone server 1..15 254: automatic time zone - e.g. UTC 255: internal user defined time zone (SET only used for digital clocks)
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..255  

mbnscTimeZoneEntry1 1.3.6.1.4.1.13842.6.2.3.3
Time Zone entry -> see special definition
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(18)  

mbnscTimeZoneEntry2 1.3.6.1.4.1.13842.6.2.3.4
Time Zone entry -> see special definition
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(18)  

mbnscTimeZoneEntry3 1.3.6.1.4.1.13842.6.2.3.5
Time Zone entry -> see special definition
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(18)  

mbnscTimeZoneEntry4 1.3.6.1.4.1.13842.6.2.3.6
Time Zone entry -> see special definition
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(18)  

mbnscTimeZoneEntry5 1.3.6.1.4.1.13842.6.2.3.7
Time Zone entry -> see special definition
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(18)  

mbnscTimeZoneEntry6 1.3.6.1.4.1.13842.6.2.3.8
Time Zone entry -> see special definition
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(18)  

mbnscTimeZoneEntry7 1.3.6.1.4.1.13842.6.2.3.9
Time Zone entry -> see special definition
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(18)  

mbnscTimeZoneConfigCmd 1.3.6.1.4.1.13842.6.2.3.100
Time zone configuration changed command variable. 0: Not defined 1: SNMP has changed the configuration (possible restart of device) 2: SNMP requests to restore the old configuration
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..2  

mbnscTimeZoneConfigChangedTime 1.3.6.1.4.1.13842.6.2.3.101
Time of the last configuration change.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

mbnscMode 1.3.6.1.4.1.13842.6.2.4
OBJECT IDENTIFIER    

mbnscModeSwitchInfo 1.3.6.1.4.1.13842.6.2.4.1
Current switch settings (only analogue movements)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

mbnscModeDisplayBrightness 1.3.6.1.4.1.13842.6.2.4.2
Display brightness for digital clocks 1..30, A (Auto)
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..2)  

mbnscModeDisplayFormat 1.3.6.1.4.1.13842.6.2.4.3
Display format 12h/24h for digital clocks
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..2)  

mbnscModeDisplayAlternate 1.3.6.1.4.1.13842.6.2.4.4
Display alternating mode for digital clocks 1: time continuously 2: date cont. 3: temperature cont. (sequence 6 sec. time, 3 sec. date for ECO-DC) 4: stopwatch cont. (only DC clock) 5: sequence 6 sec. time, 3 sec. date (only DC clock) 6: sequence 8 sec. time, 3 sec. date, 3 sec. temperature (only DC clock)
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..2)  

mbnscModeNTP 1.3.6.1.4.1.13842.6.2.4.5
NTP synchronisation mode for digital clocks
Status: obsolete Access: not-accessible
OBJECT-TYPE    
  DisplayString Size(0..2)  

mbnscModeIRlock 1.3.6.1.4.1.13842.6.2.4.6
IR autolock time for digital clocks (only DC clock) 1..60, U (autolock off)
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..2)  

mbnscModeTimeDispZeros 1.3.6.1.4.1.13842.6.2.4.7
Leading zeros time display for digital clocks (only DC clock) 1: time with leading zero 2: time without leading zero
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..2)  

mbnscModeDateDispZeros 1.3.6.1.4.1.13842.6.2.4.8
Leading zeros date display for digital clocks (only DC clock) 1: date with leading zero 2: date without leading zero
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..2)  

mbnscModeTempUnit 1.3.6.1.4.1.13842.6.2.4.9
Temperature unit for digital clocks (only DC clock) C: Celsius F: Fahrenheit
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..2)  

mbnscModeClockOpMode 1.3.6.1.4.1.13842.6.2.4.10
Operation mode for digital clocks (only DC clock) 0: normal mode 1: special mode 1 2: special mode 2
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..2)  

mbnscModeNWParam 1.3.6.1.4.1.13842.6.2.4.11
Network parameter setting mode for digital clocks
Status: obsolete Access: not-accessible
OBJECT-TYPE    
  DisplayString Size(0..2)  

mbnscModeDispDerating 1.3.6.1.4.1.13842.6.2.4.12
Display current deration setting for digital clocks (see service menu definition)
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..2)  

mbnscModeLightCorr 1.3.6.1.4.1.13842.6.2.4.13
Light measurement correction for digital clocks (see service menu definition)
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..2)  

mbnscAdditionalDigitalClockModes 1.3.6.1.4.1.13842.6.2.4.30
OBJECT IDENTIFIER    

mbnscSensors 1.3.6.1.4.1.13842.6.2.4.30.1
OBJECT IDENTIFIER    

mbnscSensorsTempActivation 1.3.6.1.4.1.13842.6.2.4.30.1.1
Temperature sensor activation 1: DS18B20 3: TME (only sensor 1) 4: TME (Sensors 1 and 2)
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..2)  

mbnscSensorsTemp1IPAddr 1.3.6.1.4.1.13842.6.2.4.30.1.2
IP network address (xxx.xxx.xxx.xxx) of the sensor 1 (SET only used for digital clocks)
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

mbnscSensorsTemp2IPAddr 1.3.6.1.4.1.13842.6.2.4.30.1.3
IP network address (xxx.xxx.xxx.xxx) of the sensor 2 (SET only used for digital clocks)
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

mbnscSensorsConfigCmd 1.3.6.1.4.1.13842.6.2.4.30.1.100
Mode configuration changed command variable. 0: Not defined 1: SNMP has changed the configuration (possible restart of device) 2: SNMP requests to restore the old configuration
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..2  

mbnscSensorsConfigChangedTime 1.3.6.1.4.1.13842.6.2.4.30.1.101
Time of the last configuration change.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

mbnscDA 1.3.6.1.4.1.13842.6.2.4.30.2
OBJECT IDENTIFIER    

mbnscDASecondCircleDisplay 1.3.6.1.4.1.13842.6.2.4.30.2.1
The second circle display mode 1: Accumulating ring of seconds marker 2: Take actual second from full shining circle step by step 3: Full shining circle, actual second off 4: Three shining seconds, the first is showing actual second 5: Two shining seconds, the first is showing actual second
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..2)  

mbnscDAConfigCmd 1.3.6.1.4.1.13842.6.2.4.30.2.100
Mode configuration changed command variable. 0: Not defined 1: SNMP has changed the configuration (possible restart of device) 2: SNMP requests to restore the old configuration
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..2  

mbnscDAConfigChangedTime 1.3.6.1.4.1.13842.6.2.4.30.2.101
Time of the last configuration change.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

mbnscDK 1.3.6.1.4.1.13842.6.2.4.30.3
OBJECT IDENTIFIER    

mbnscDKFirstLanguage 1.3.6.1.4.1.13842.6.2.4.30.3.1
First language selection 1: Czech 2: Slovak 3: English 4: German 5: ... (see manual for full language list)
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..2)  

mbnscDKSecondLanguage 1.3.6.1.4.1.13842.6.2.4.30.3.2
Second language selection 1: Czech 2: Slovak 3: English 4: German 5: ... (see manual for full language list)
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..2)  

mbnscDKThirdLanguage 1.3.6.1.4.1.13842.6.2.4.30.3.3
Third language selection 1: Czech 2: Slovak 3: English 4: German 5: ... (see manual for full language list)
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..2)  

mbnscDKTempUnitSecondLang 1.3.6.1.4.1.13842.6.2.4.30.3.4
Temperature units for second selected language C: Celsius F: Fahrenheit
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..2)  

mbnscDKTempUnitThirdLang 1.3.6.1.4.1.13842.6.2.4.30.3.5
Temperature units for third selected language C: Celsius F: Fahrenheit
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..2)  

mbnscDKAutoLangSwitchOver 1.3.6.1.4.1.13842.6.2.4.30.3.6
Language switch mode for automatic language switching over in one display alternating cycle A: all languages S: simple language
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..2)  

mbnscDKNumOfCharsForWeekday 1.3.6.1.4.1.13842.6.2.4.30.3.7
Number of characters used for weekday names 2: two characters 3: three characters
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..2)  

mbnscDKNamesFormatDisplay 1.3.6.1.4.1.13842.6.2.4.30.3.8
Weekday and month display format 1: first capital 2: all capitals
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..2)  

mbnscDKTemp1DescriptEnable 1.3.6.1.4.1.13842.6.2.4.30.3.9
Display of description for first measured temperature N/Y
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..2)  

mbnscDKTemp1Description 1.3.6.1.4.1.13842.6.2.4.30.3.10
Description text for first measured temperature
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..5)  

mbnscDKTemp2DescriptEnable 1.3.6.1.4.1.13842.6.2.4.30.3.11
Display of description for second measured temperature N/Y
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..2)  

mbnscDKTemp2Description 1.3.6.1.4.1.13842.6.2.4.30.3.12
Description text for second measured temperature
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..5)  

mbnscDKWorldTimeZone1 1.3.6.1.4.1.13842.6.2.4.30.3.13
Index of time zone for world time zone 1 0: UTC 1..64: See user manual, time zone table 65..128: user defined time zone 129..143: time zone server 1..15 255: none (SET only used for digital clocks)
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..255  

mbnscDKWorldTimeZone1Description 1.3.6.1.4.1.13842.6.2.4.30.3.14
Description text for World time zone 1
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..8)  

mbnscDKWorldTimeZone2 1.3.6.1.4.1.13842.6.2.4.30.3.15
Index of time zone for world time zone 2 0: UTC 1..64: See user manual, time zone table 65..128: user defined time zone 129..143: time zone server 1..15 255: none (SET only used for digital clocks)
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..255  

mbnscDKWorldTimeZone2Description 1.3.6.1.4.1.13842.6.2.4.30.3.16
Description text for World time zone 2
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..8)  

mbnscDKWorldTimeZone3 1.3.6.1.4.1.13842.6.2.4.30.3.17
Index of time zone for world time zone 3 0: UTC 1..64: See user manual, time zone table 65..128: user defined time zone 129..143: time zone server 1..15 255: none (SET only used for digital clocks)
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..255  

mbnscDKWorldTimeZone3Description 1.3.6.1.4.1.13842.6.2.4.30.3.18
Description text for World time zone 3
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..8)  

mbnscDKWorldTimeZone4 1.3.6.1.4.1.13842.6.2.4.30.3.19
Index of time zone for world time zone 4 0: UTC 1..64: See user manual, time zone table 65..128: user defined time zone 129..143: time zone server 1..15 255: none (SET only used for digital clocks)
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..255  

mbnscDKWorldTimeZone4Description 1.3.6.1.4.1.13842.6.2.4.30.3.20
Description text for World time zone 4
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..8)  

mbnscDKWorldTimeZone5 1.3.6.1.4.1.13842.6.2.4.30.3.21
Index of time zone for world time zone 5 0: UTC 1..64: See user manual, time zone table 65..128: user defined time zone 129..143: time zone server 1..15 255: none (SET only used for digital clocks)
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..255  

mbnscDKWorldTimeZone5Description 1.3.6.1.4.1.13842.6.2.4.30.3.22
Description text for World time zone 5
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..8)  

mbnscDKAutoTimeZoneSwitchOver 1.3.6.1.4.1.13842.6.2.4.30.3.23
World time switch mode for automatic time zone switching over in one display alternating cycle A: all world time zones S: simple world time zone
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..2)  

mbnscDKConfigCmd 1.3.6.1.4.1.13842.6.2.4.30.3.100
Mode configuration changed command variable. 0: Not defined 1: SNMP has changed the configuration (possible restart of device) 2: SNMP requests to restore the old configuration
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..2  

mbnscDKConfigChangedTime 1.3.6.1.4.1.13842.6.2.4.30.3.101
Time of the last configuration change.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

mbnscModeConfigCmd 1.3.6.1.4.1.13842.6.2.4.100
Mode configuration changed command variable. 0: Not defined 1: SNMP has changed the configuration (possible restart of device) 2: SNMP requests to restore the old configuration
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..2  

mbnscModeConfigChangedTime 1.3.6.1.4.1.13842.6.2.4.101
Time of the last configuration change.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

mbnscAdditionalInterfaceModes 1.3.6.1.4.1.13842.6.2.4.40
OBJECT IDENTIFIER    

mbnscNMI 1.3.6.1.4.1.13842.6.2.4.40.1
OBJECT IDENTIFIER    

mbnscNMIDCFCurrentLoop 1.3.6.1.4.1.13842.6.2.4.40.1.1
Operation mode of the DCF77 current loop. 0: OFF 1: ON
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(0), on(1)  

mbnscNMILineDriver 1.3.6.1.4.1.13842.6.2.4.40.1.2
Operation mode of the line driver. 0: OFF 1: MOBALine 2: Active DCF
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(0), mobaline(1), activdcf(2)  

mbnscNMIMOBALineMode 1.3.6.1.4.1.13842.6.2.4.40.1.3
Operation mode of MOBALine. 0: normal operation 1: 12:00 mode, sideclocks shows 12:00 position 2: clock-id mode, sideclocks shows their ids if configured
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER normal(0), command12h(1), clockidcommand(2)  

mbnscNMIMOBALineMinuteHandMode 1.3.6.1.4.1.13842.6.2.4.40.1.4
Minute hand mode operation of MOBALine. 0: minute step mode 1: half minute step mode 2: continuous mode
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER minutestep(0), halfminutestep(1), continuous(2)  

mbnscNMIActiveDCFMode 1.3.6.1.4.1.13842.6.2.4.40.1.5
Operation mode of Active DCF. 1: Mode 1 2: Mode 2 3: Mode 3 4: Mode 4 5: Mode 5 6: Mode 6
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER mode1(1), mode2(2), mode3(3), mode4(4), mode5(5), mode6(6)  

mbnscNMIConfigCmd 1.3.6.1.4.1.13842.6.2.4.40.1.100
General configuration changed command variable. 0: Not defined 1: SNMP has changed the configuration (possible restart of device) 2: SNMP requests to restore the old configuration
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..2  

mbnscNMIConfigChangedTime 1.3.6.1.4.1.13842.6.2.4.40.1.101
Time of the last configuration change.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

mbnscNMISideClockState 1.3.6.1.4.1.13842.6.2.4.40.1.20
OBJECT IDENTIFIER    

mbnscNMISideClock1 1.3.6.1.4.1.13842.6.2.4.40.1.20.1
State of side clock 1 0: Clock not configured 3: Clock OK 5: Clock error
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notconfigured(0), clockok(3), clockerror(5)  

mbnscNMISideClock2 1.3.6.1.4.1.13842.6.2.4.40.1.20.2
State of side clock 2 0: Clock not configured 3: Clock OK 5: Clock error
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notconfigured(0), clockok(3), clockerror(5)  

mbnscNMISideClock3 1.3.6.1.4.1.13842.6.2.4.40.1.20.3
State of side clock 3 0: Clock not configured 3: Clock OK 5: Clock error
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notconfigured(0), clockok(3), clockerror(5)  

mbnscNMISideClock4 1.3.6.1.4.1.13842.6.2.4.40.1.20.4
State of side clock 4 0: Clock not configured 3: Clock OK 5: Clock error
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notconfigured(0), clockok(3), clockerror(5)  

mbnscNMISideClock5 1.3.6.1.4.1.13842.6.2.4.40.1.20.5
State of side clock 5 0: Clock not configured 3: Clock OK 5: Clock error
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notconfigured(0), clockok(3), clockerror(5)  

mbnscNMISideClock6 1.3.6.1.4.1.13842.6.2.4.40.1.20.6
State of side clock 6 0: Clock not configured 3: Clock OK 5: Clock error
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notconfigured(0), clockok(3), clockerror(5)  

mbnscNMISideClock7 1.3.6.1.4.1.13842.6.2.4.40.1.20.7
State of side clock 7 0: Clock not configured 3: Clock OK 5: Clock error
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notconfigured(0), clockok(3), clockerror(5)  

mbnscNMISideClock8 1.3.6.1.4.1.13842.6.2.4.40.1.20.8
State of side clock 8 0: Clock not configured 3: Clock OK 5: Clock error
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notconfigured(0), clockok(3), clockerror(5)  

mbnscNMISideClock9 1.3.6.1.4.1.13842.6.2.4.40.1.20.9
State of side clock 9 0: Clock not configured 3: Clock OK 5: Clock error
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notconfigured(0), clockok(3), clockerror(5)  

mbnscNMISideClock10 1.3.6.1.4.1.13842.6.2.4.40.1.20.10
State of side clock 10 0: Clock not configured 3: Clock OK 5: Clock error
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notconfigured(0), clockok(3), clockerror(5)  

mbnscNMISideClock11 1.3.6.1.4.1.13842.6.2.4.40.1.20.11
State of side clock 11 0: Clock not configured 3: Clock OK 5: Clock error
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notconfigured(0), clockok(3), clockerror(5)  

mbnscNMISideClock12 1.3.6.1.4.1.13842.6.2.4.40.1.20.12
State of side clock 12 0: Clock not configured 3: Clock OK 5: Clock error
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notconfigured(0), clockok(3), clockerror(5)  

mbnscGeneral 1.3.6.1.4.1.13842.6.2.5
OBJECT IDENTIFIER    

mbnscGeneralType 1.3.6.1.4.1.13842.6.2.5.1
Network slave clock type 1 Network Clock Interface NCI 2 Wireless Time Distribution WTD 868-T 3 NTP movement SEN 00 4 NTP movement NBU 190 5 Digital Clock ECO-DC 6 Digital Clock DC3 7 NTP movement SEN 40 8 NTP movement SAN 40 9 NTP digital clock DA 10 NTP calendar digital clock DK2 11 Network MOBALine Interface NMI 12 NTP clock TREND 13 NTP clock TREND double sided 14 NTP in- and outdoor digital clock DSC
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..14  

mbnscGeneralName 1.3.6.1.4.1.13842.6.2.5.2
Device name (identifier)
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..20)  

mbnscGeneralFirmwareNumber 1.3.6.1.4.1.13842.6.2.5.3
Article number of the firmware.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(6)  

mbnscGeneralFirmwareVer 1.3.6.1.4.1.13842.6.2.5.4
Firmware version.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(4)  

mbnscGeneralStatus 1.3.6.1.4.1.13842.6.2.5.5
Network slave clock status (64bit). Internal state of the network slave clock. Used for maintenance only. Bit 00 : time ok Bit 01 : 12h position Bit 02 : Reserved Bit 03 : Reserved Bit 04 : Reserved Bit 05 : Reserved Bit 06 : Reserved Bit 07 : Reserved Bit 08 : Reserved Bit 09 : Reserved Bit 10 : Reserved Bit 11 : Reserved Bit 12 : Reserved Bit 13 : Reserved Bit 14 : Reserved Bit 15 : Reserved Bit 16 : Reserved Bit 17 : Reserved Bit 18 : Reserved Bit 19 : Reserved Bit 20 : Reserved Bit 21 : Reserved Bit 22 : Reserved Bit 23 : Reserved Bit 24 : Reserved Bit 25 : Reserved Bit 26 : Reserved Bit 27 : Reserved Bit 28 : Reserved Bit 29 : Reserved Bit 30 : Reserved Bit 31 : Reserved Bit32..63 not used
Status: current Access: read-only
OBJECT-TYPE    
  MOBAFlags64  

mbnscGeneralAlarms 1.3.6.1.4.1.13842.6.2.5.6
Alarm state of the network slave clock Bit00=Synchronization Bit01=Power supply Bit02=Slave (cascade) Bit03=Illumination Bit04=Hands position (sec) Bit05=Hands position (m/h) Bit06=Restart Bit07=CommError Bit08=Time zone Bit09=Reserved Bit10=Reserved Bit11=Reserved Bit12=Reserved Bit13=Reserved Bit14=Reserved Bit15=Reserved Bit16=Reserved Bit17=Reserved Bit18=Reserved Bit19=Reserved Bit20=Reserved Bit21=Reserved Bit22=Reserved Bit23=Reserved Bit24=Reserved Bit25=Reserved Bit26=Reserved Bit27=Reserved Bit28=Reserved Bit29=Reserved Bit30=Reserved Bit31=Reserved Bit32..Bit63=Device type specific error
Status: current Access: read-only
OBJECT-TYPE    
  MOBAAlarm64  

mbnscGeneralSlaveInfo1 1.3.6.1.4.1.13842.6.2.5.7
Info from slave 1 Byte 0..5 MAC Byte 6..11 Slave local time Byte 12..17 SW-number Byte 18..21 SW-version Byte 22 state Byte 23 reserved Byte 24 error Byte 25 reserved
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(26)  

mbnscGeneralSlaveInfo2 1.3.6.1.4.1.13842.6.2.5.8
Info from slave 2 Byte 0..5 MAC Byte 6..11 Slave local time Byte 12..17 SW-number Byte 18..21 SW-version Byte 22 state Byte 23 reserved Byte 24 error Byte 25 reserved
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(26)  

mbnscGeneralSlaveInfo3 1.3.6.1.4.1.13842.6.2.5.9
Info from slave 3 Byte 0..5 MAC Byte 6..11 Slave local time Byte 12..17 SW-number Byte 18..21 SW-version Byte 22 state Byte 23 reserved Byte 24 error Byte 25 reserved
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(26)  

mbnscGeneralConfigCmd 1.3.6.1.4.1.13842.6.2.5.100
General configuration changed command variable. 0: Not defined 1: SNMP has changed the configuration (possible restart of device) 2: SNMP requests to restore the old configuration
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..2  

mbnscGeneralConfigChangedTime 1.3.6.1.4.1.13842.6.2.5.101
Time of the last configuration change.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

mbnscSupervision 1.3.6.1.4.1.13842.6.2.6
OBJECT IDENTIFIER    

mbnscSNMPManager1 1.3.6.1.4.1.13842.6.2.6.1
String with IPv4 or IPv6 address (e.g 192.168.3.4 or FD03:2345:2345:2345::231) of the SNMP manager 1
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..40)  

mbnscSNMPManager2 1.3.6.1.4.1.13842.6.2.6.2
String with IPv4 or IPv6 address (e.g 192.168.3.4 or FD03:2345:2345:2345::231) of the SNMP manager 2
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..40)  

mbnscSNMPTrapAliveMsgInterval 1.3.6.1.4.1.13842.6.2.6.3
Time interval to send the alive message to the trap listener stations. 0: Alive message disabled >0: Alive message enabled Range: 1 ... 1440 minutes
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0 | 1..1440  

mbnscSNMPConfigCmd 1.3.6.1.4.1.13842.6.2.6.100
SNMP / supervision services configuration changed command variable. 0: Not defined 1: SNMP has changed the configuration (possible restart of device) 2: SNMP requests to restore the old configuration
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..2  

mbnscSNMPConfigChangedTime 1.3.6.1.4.1.13842.6.2.6.101
Time of the last configuration change.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

mbnscCommand 1.3.6.1.4.1.13842.6.2.7
OBJECT IDENTIFIER    

mbnscCommand12Pos 1.3.6.1.4.1.13842.6.2.7.1
Mode of the analogue clock: 0=run, 1=12h position
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..1  

mbnscCommandSWReset 1.3.6.1.4.1.13842.6.2.7.2
Command SW reset if set to 1
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..1  

mbnscCommandFactorySetting 1.3.6.1.4.1.13842.6.2.7.3
Restore factory settings if set to 1
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..1  

mbnscCommandFirmwUpd 1.3.6.1.4.1.13842.6.2.7.4
Command to start FW update
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(10)  

mbnscCommandExtContact 1.3.6.1.4.1.13842.6.2.7.5
Set external contact
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..1  

mbnscCommandConfigCmd 1.3.6.1.4.1.13842.6.2.7.100
SNMP / supervision services configuration changed command variable. 0: Not defined 1: SNMP has changed the configuration (possible restart of device) 2: SNMP requests to restore the old configuration
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..2  

mbnscSnmpConfig 1.3.6.1.4.1.13842.6.2.9
OBJECT IDENTIFIER    

mbnscSnmpCurrentAlarmInfo 1.3.6.1.4.1.13842.6.2.9.1
OBJECT IDENTIFIER    

mbnscTrapAlMsgErrorNr 1.3.6.1.4.1.13842.6.2.9.1.1
Error number of the trap message.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Unsigned32 0..63  

mbnscTrapAlMsgErrorState 1.3.6.1.4.1.13842.6.2.9.1.2
Error state of the trap message.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Unsigned32 0..1  

mbnscTrapAlMsgErrorTime 1.3.6.1.4.1.13842.6.2.9.1.3
Error time of the trap message. Seconds since 1.1.1970 00:00:00
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Unsigned32  

mbnscTraps 1.3.6.1.4.1.13842.6.2.10
OBJECT IDENTIFIER    

mbnscTrapsAlarm 1.3.6.1.4.1.13842.6.2.10.1
Alarm trap with attached (binded variables) alarm information. mbnscTrapAlMsgErrorNr, mbnscTrapAlMsgErrorState, mbnscTrapAlMsgErrorTime
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

mbnscTrapsAlive 1.3.6.1.4.1.13842.6.2.10.2
Device alive trap. Will be send in the configured interval. Attached are the variables mbnscGeneralStatus and mbnscGeneralAlarms.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

mbnscMIBCompliance 1.3.6.1.4.1.13842.6.100.1
OBJECT IDENTIFIER    

mbnscMIBCompliances 1.3.6.1.4.1.13842.6.100.1.1
Please replace this text with your description.
Status: current Access: accessible-for-notify
MODULE-COMPLIANCE    

mbnscMIBGroups 1.3.6.1.4.1.13842.6.100.2
OBJECT IDENTIFIER    

mbnscAllNotifications 1.3.6.1.4.1.13842.6.100.2.1
This automatically created notification group contains all notifications that do not belong to any other NOTIFICATION-GROUP
Status: current Access: accessible-for-notify
NOTIFICATION-GROUP    

mbnscGrpNBU190 1.3.6.1.4.1.13842.6.100.2.2
All parameters used for NBU 190 movement
Status: current Access: accessible-for-notify
OBJECT-GROUP    

mbnscGrpSEN40 1.3.6.1.4.1.13842.6.100.2.3
All parameters used for SEN 40 movement
Status: current Access: accessible-for-notify
OBJECT-GROUP    

mbnscGrpDC 1.3.6.1.4.1.13842.6.100.2.4
All parameters used for DC digital clock
Status: current Access: accessible-for-notify
OBJECT-GROUP    

mbnscGrpECODC 1.3.6.1.4.1.13842.6.100.2.5
All parameters used for ECO DC digital clock
Status: current Access: accessible-for-notify
OBJECT-GROUP    

mbnscGrpDA 1.3.6.1.4.1.13842.6.100.2.6
All parameters used for DA digital clock
Status: current Access: accessible-for-notify
OBJECT-GROUP    

mbnscGrpDK 1.3.6.1.4.1.13842.6.100.2.7
All parameters used for DK digital clock
Status: current Access: accessible-for-notify
OBJECT-GROUP    

mbnscGrpNMI 1.3.6.1.4.1.13842.6.100.2.8
All parameters used for Network-MOBALine-Interface NMI
Status: current Access: accessible-for-notify
OBJECT-GROUP    

mbnscGrpNotUsedParameters 1.3.6.1.4.1.13842.6.100.2.100
All parameters not used in oother groups
Status: current Access: accessible-for-notify
OBJECT-GROUP