ME1200-TT-LOOP-MIB

File: ME1200-TT-LOOP-MIB.mib (14547 bytes)

Imported modules

SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
CISCOME1200-MIB ME1200-TC

Imported symbols

MODULE-COMPLIANCE OBJECT-GROUP MODULE-IDENTITY
OBJECT-TYPE TEXTUAL-CONVENTION me1200SwitchMgmt
ME1200DisplayString ME1200InterfaceIndex ME1200RowEditorState
Integer32 Unsigned32

Defined Types

ME1200TtLoopInstanceAdminState  
The instance Administrative State.
TEXTUAL-CONVENTION    
  INTEGER adminDisabled(0), adminEnabled(1)  

ME1200TtLoopInstanceDirection  
The instance direction.
TEXTUAL-CONVENTION    
  INTEGER facility(0), terminal(1)  

ME1200TtLoopInstanceDomain  
The instance domain.
TEXTUAL-CONVENTION    
  INTEGER port(0), evc(1), vlan(2)  

ME1200TtLoopInstanceOperState  
The instance Operational State.
TEXTUAL-CONVENTION    
  INTEGER operDown(0), operUp(1)  

ME1200TtLoopInstanceSubscriber  
The instance subscriber mode.
TEXTUAL-CONVENTION    
  INTEGER none(0), all(1), test(2)  

ME1200TtLoopInstanceType  
The instance type.
TEXTUAL-CONVENTION    
  INTEGER macLoop(0), oamLoop(1)  

ME1200TtLoopConfigInstanceEntry  
SEQUENCE    
  me1200TtLoopConfigInstanceId Integer32
  me1200TtLoopConfigInstanceName ME1200DisplayString
  me1200TtLoopConfigInstanceType ME1200TtLoopInstanceType
  me1200TtLoopConfigInstanceDirection ME1200TtLoopInstanceDirection
  me1200TtLoopConfigInstanceDomain ME1200TtLoopInstanceDomain
  me1200TtLoopConfigInstanceFlow Unsigned32
  me1200TtLoopConfigInstancePort ME1200InterfaceIndex
  me1200TtLoopConfigInstanceLevel Unsigned32
  me1200TtLoopConfigInstanceSubscriber ME1200TtLoopInstanceSubscriber
  me1200TtLoopConfigInstanceAdminState ME1200TtLoopInstanceAdminState
  me1200TtLoopConfigInstanceAction ME1200RowEditorState

ME1200TtLoopStatusInstanceEntry  
SEQUENCE    
  me1200TtLoopStatusInstanceId Integer32
  me1200TtLoopStatusInstanceOperState ME1200TtLoopInstanceOperState

Defined Values

me1200TtLoopMib 1.3.6.1.4.1.9.9.815.1.128
This is a private Traffic Test Loop MIB that can be used for RFC2544 and Y.1564 (remote end) testing
MODULE-IDENTITY    

me1200TtLoopMibObjects 1.3.6.1.4.1.9.9.815.1.128.1
OBJECT IDENTIFIER    

me1200TtLoopCapabilities 1.3.6.1.4.1.9.9.815.1.128.1.1
OBJECT IDENTIFIER    

me1200TtLoopCapabilitiesInstanceMax 1.3.6.1.4.1.9.9.815.1.128.1.1.1
Max number of TT_LOOP instance
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

me1200TtLoopCapabilitiesNameMax 1.3.6.1.4.1.9.9.815.1.128.1.1.2
Max length of instance name
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

me1200TtLoopConfig 1.3.6.1.4.1.9.9.815.1.128.1.2
OBJECT IDENTIFIER    

me1200TtLoopConfigInstanceTable 1.3.6.1.4.1.9.9.815.1.128.1.2.1
This is a table of created instance configuration parameters
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ME1200TtLoopConfigInstanceEntry

me1200TtLoopConfigInstanceEntry 1.3.6.1.4.1.9.9.815.1.128.1.2.1.1
This is a created instance configuration parameters. Not all parameters can be changed
Status: current Access: not-accessible
OBJECT-TYPE    
  ME1200TtLoopConfigInstanceEntry  

me1200TtLoopConfigInstanceId 1.3.6.1.4.1.9.9.815.1.128.1.2.1.1.1
The TT_LOOP instance ID
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..2147483647  

me1200TtLoopConfigInstanceName 1.3.6.1.4.1.9.9.815.1.128.1.2.1.1.2
Instance name
Status: current Access: read-write
OBJECT-TYPE    
  ME1200DisplayString Size(0..32)  

me1200TtLoopConfigInstanceType 1.3.6.1.4.1.9.9.815.1.128.1.2.1.1.3
The Traffic Test loop type. Currently only MAC Loop is supported
Status: current Access: read-write
OBJECT-TYPE    
  ME1200TtLoopInstanceType  

me1200TtLoopConfigInstanceDirection 1.3.6.1.4.1.9.9.815.1.128.1.2.1.1.4
The instance direction. Currently only Facility Loop is supported
Status: current Access: read-write
OBJECT-TYPE    
  ME1200TtLoopInstanceDirection  

me1200TtLoopConfigInstanceDomain 1.3.6.1.4.1.9.9.815.1.128.1.2.1.1.5
The instance domain. Currently only Port domain is supported
Status: current Access: read-write
OBJECT-TYPE    
  ME1200TtLoopInstanceDomain  

me1200TtLoopConfigInstanceFlow 1.3.6.1.4.1.9.9.815.1.128.1.2.1.1.6
The flow instance (VLAN - EVC).
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

me1200TtLoopConfigInstancePort 1.3.6.1.4.1.9.9.815.1.128.1.2.1.1.7
The instance residence port.
Status: current Access: read-write
OBJECT-TYPE    
  ME1200InterfaceIndex  

me1200TtLoopConfigInstanceLevel 1.3.6.1.4.1.9.9.815.1.128.1.2.1.1.8
The instance MEG level
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

me1200TtLoopConfigInstanceSubscriber 1.3.6.1.4.1.9.9.815.1.128.1.2.1.1.9
The EVC OAM loop subscriber mode
Status: current Access: read-write
OBJECT-TYPE    
  ME1200TtLoopInstanceSubscriber  

me1200TtLoopConfigInstanceAdminState 1.3.6.1.4.1.9.9.815.1.128.1.2.1.1.10
The instance Administrative state.
Status: current Access: read-write
OBJECT-TYPE    
  ME1200TtLoopInstanceAdminState  

me1200TtLoopConfigInstanceAction 1.3.6.1.4.1.9.9.815.1.128.1.2.1.1.100
Action
Status: current Access: read-write
OBJECT-TYPE    
  ME1200RowEditorState  

me1200TtLoopConfigInstanceRowEditor 1.3.6.1.4.1.9.9.815.1.128.1.2.2
OBJECT IDENTIFIER    

me1200TtLoopConfigInstanceRowEditorId 1.3.6.1.4.1.9.9.815.1.128.1.2.2.1
The TT_LOOP instance ID
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..2147483647  

me1200TtLoopConfigInstanceRowEditorName 1.3.6.1.4.1.9.9.815.1.128.1.2.2.2
Instance name
Status: current Access: read-write
OBJECT-TYPE    
  ME1200DisplayString Size(0..32)  

me1200TtLoopConfigInstanceRowEditorType 1.3.6.1.4.1.9.9.815.1.128.1.2.2.3
The Traffic Test loop type. Currently only MAC Loop is supported
Status: current Access: read-write
OBJECT-TYPE    
  ME1200TtLoopInstanceType  

me1200TtLoopConfigInstanceRowEditorDirection 1.3.6.1.4.1.9.9.815.1.128.1.2.2.4
The instance direction. Currently only Facility Loop is supported
Status: current Access: read-write
OBJECT-TYPE    
  ME1200TtLoopInstanceDirection  

me1200TtLoopConfigInstanceRowEditorDomain 1.3.6.1.4.1.9.9.815.1.128.1.2.2.5
The instance domain. Currently only Port domain is supported
Status: current Access: read-write
OBJECT-TYPE    
  ME1200TtLoopInstanceDomain  

me1200TtLoopConfigInstanceRowEditorFlow 1.3.6.1.4.1.9.9.815.1.128.1.2.2.6
The flow instance (VLAN - EVC).
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

me1200TtLoopConfigInstanceRowEditorPort 1.3.6.1.4.1.9.9.815.1.128.1.2.2.7
The instance residence port.
Status: current Access: read-write
OBJECT-TYPE    
  ME1200InterfaceIndex  

me1200TtLoopConfigInstanceRowEditorLevel 1.3.6.1.4.1.9.9.815.1.128.1.2.2.8
The instance MEG level
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

me1200TtLoopConfigInstanceRowEditorSubscriber 1.3.6.1.4.1.9.9.815.1.128.1.2.2.9
The EVC OAM loop subscriber mode
Status: current Access: read-write
OBJECT-TYPE    
  ME1200TtLoopInstanceSubscriber  

me1200TtLoopConfigInstanceRowEditorAdminState 1.3.6.1.4.1.9.9.815.1.128.1.2.2.10
The instance Administrative state.
Status: current Access: read-write
OBJECT-TYPE    
  ME1200TtLoopInstanceAdminState  

me1200TtLoopConfigInstanceRowEditorAction 1.3.6.1.4.1.9.9.815.1.128.1.2.2.100
Action
Status: current Access: read-write
OBJECT-TYPE    
  ME1200RowEditorState  

me1200TtLoopStatus 1.3.6.1.4.1.9.9.815.1.128.1.3
OBJECT IDENTIFIER    

me1200TtLoopStatusInstanceTable 1.3.6.1.4.1.9.9.815.1.128.1.3.1
This is a table of created instance status
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ME1200TtLoopStatusInstanceEntry

me1200TtLoopStatusInstanceEntry 1.3.6.1.4.1.9.9.815.1.128.1.3.1.1
This is a created instance status
Status: current Access: not-accessible
OBJECT-TYPE    
  ME1200TtLoopStatusInstanceEntry  

me1200TtLoopStatusInstanceId 1.3.6.1.4.1.9.9.815.1.128.1.3.1.1.1
The TT_LOOP instance ID
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..2147483647  

me1200TtLoopStatusInstanceOperState 1.3.6.1.4.1.9.9.815.1.128.1.3.1.1.2
The instance Operational state.
Status: current Access: read-only
OBJECT-TYPE    
  ME1200TtLoopInstanceOperState  

me1200TtLoopMibConformance 1.3.6.1.4.1.9.9.815.1.128.3
OBJECT IDENTIFIER    

me1200TtLoopMibCompliances 1.3.6.1.4.1.9.9.815.1.128.3.1
OBJECT IDENTIFIER    

me1200TtLoopMibGroups 1.3.6.1.4.1.9.9.815.1.128.3.2
OBJECT IDENTIFIER    

me1200TtLoopCapabilitiesInfoGroup 1.3.6.1.4.1.9.9.815.1.128.3.2.1
A collection of objects suitable for bulk operations.
Status: current Access: read-only
OBJECT-GROUP    

me1200TtLoopConfigInstanceTableInfoGroup 1.3.6.1.4.1.9.9.815.1.128.3.2.2
A collection of objects suitable for bulk operations.
Status: current Access: read-only
OBJECT-GROUP    

me1200TtLoopConfigInstanceRowEditorInfoGroup 1.3.6.1.4.1.9.9.815.1.128.3.2.3
A collection of objects suitable for bulk operations.
Status: current Access: read-only
OBJECT-GROUP    

me1200TtLoopStatusInstanceTableInfoGroup 1.3.6.1.4.1.9.9.815.1.128.3.2.4
A collection of objects suitable for bulk operations.
Status: current Access: read-only
OBJECT-GROUP    

me1200TtLoopMibCompliance 1.3.6.1.4.1.9.9.815.1.128.3.1.1
The compliance statement for the implementation.
Status: current Access: read-only
MODULE-COMPLIANCE