LINKSYS-MIB

File: LINKSYS-MIB.mib (22706 bytes)

Imported modules

SNMPv2-SMI RFC1155-SMI RFC-1212

Imported symbols

Counter64 enterprises Counter
OBJECT-TYPE

Defined Types

Sp2CtlEntry  
SEQUENCE    
  ctlHubIdx INTEGER
  ctlPortIdx INTEGER
  enable INTEGER
  linkEn INTEGER
  speedSet INTEGER
  nwayEn INTEGER
  nwayRestart INTEGER

Sp2StEntry  
SEQUENCE    
  statHubIdx INTEGER
  statPortIdx INTEGER
  linkSt INTEGER
  polaritySt INTEGER
  partitionSt INTEGER
  speedSt INTEGER
  nwayPartner INTEGER

CounterEntry  
SEQUENCE    
  cntHubIdx INTEGER
  cntPortIdx INTEGER
  portReadableFrames Counter
  portReadableOctets Counter64
  portFrameCheckSequence Counter
  portAlignmentErrors Counter
  portFramesTooLong Counter
  portShortEvents Counter
  portRunts Counter
  portCollisions Counter
  portLateEvents Counter
  portVeryLongEvents Counter
  portDataRateMismatches Counter
  portAutoPartitions Counter
  portTrackSrcAddrChanges Counter
  portBroadcastPkts Counter
  portMulticastPkts Counter

Defined Values

linksys 1.3.6.1.4.1.3955
OBJECT IDENTIFIER    

deviceId 1.3.6.1.4.1.3955.1
The value is used to identify what kind of device.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER isEtherHub(1), isFastEtherHub(2), isDualSpeedHub(3), isNwayEtherSwitch(4)  

etherHub 1.3.6.1.4.1.3955.5
OBJECT IDENTIFIER    

ehHwVer 1.3.6.1.4.1.3955.5.2
The hardware version of this device
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ehSwVer 1.3.6.1.4.1.3955.5.3
The software version of this device
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ehNumber 1.3.6.1.4.1.3955.5.4
Present the device number under this node
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sp2Hub 1.3.6.1.4.1.3955.5.5
OBJECT IDENTIFIER    

sp2Statistic 1.3.6.1.4.1.3955.5.5.1
OBJECT IDENTIFIER    

sp2Control 1.3.6.1.4.1.3955.5.5.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sp2CtlEntry

sp2Status 1.3.6.1.4.1.3955.5.5.3
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sp2StEntry

sp2Ports 1.3.6.1.4.1.3955.5.5.4
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CounterEntry

statsOctets 1.3.6.1.4.1.3955.5.5.1.1
The number of data octets including those in bad packets and octets in FCS fields, but does not include preamble or other framing bits.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter64  

statsPkts 1.3.6.1.4.1.3955.5.5.1.2
The number of packets received from the network, including errored packets.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

statsBroadcastPkts 1.3.6.1.4.1.3955.5.5.1.3
The number of good broadcast packets received.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

statsMulticastPkts 1.3.6.1.4.1.3955.5.5.1.4
The number of good multicast packets received.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

statsCrcAlignErrors 1.3.6.1.4.1.3955.5.5.1.5
The number of valid-length packets (64 to 1518 bytes inclusive) that had a bad Frame Check Sequence(FCS).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

statsUndersizePkts 1.3.6.1.4.1.3955.5.5.1.6
The number of well-formed packets that were smaller than 64 octets.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

statsOversizePkts 1.3.6.1.4.1.3955.5.5.1.7
The number of well-formed packets that were longer than 1518 octets.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

statsFragments 1.3.6.1.4.1.3955.5.5.1.8
The number of ill-formed packets less than 64 octets. note: any event without a start-of-frame delimiter (0- octet packet) will be counted as a fragment, no matter how long it is
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

statsJabbers 1.3.6.1.4.1.3955.5.5.1.9
The number of ill-formed packets longer than 1518 octets. An ill-formed packet is one with an FCS error.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

statsCollisions 1.3.6.1.4.1.3955.5.5.1.10
The best estimate of the total number of collisions on this interface
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

statsPkts64Octets 1.3.6.1.4.1.3955.5.5.1.11
The number of packets(good and bad) that were 64 octets long.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

statsPkts65to127Octets 1.3.6.1.4.1.3955.5.5.1.12
The number of packets(good and bad) between 65 and 127 octets long
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

statsPkts128to255Octets 1.3.6.1.4.1.3955.5.5.1.13
The number of packets(good and bad) between 128 and 255 octets long
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

statsPkts256to511Octets 1.3.6.1.4.1.3955.5.5.1.14
The number of packets(good and bad) between 256 and 511 octets long
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

statsPkts512to1023Octets 1.3.6.1.4.1.3955.5.5.1.15
The number of packets(good and bad) between 512 and 1023 octets long
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

statsPkts1024to1518Octets 1.3.6.1.4.1.3955.5.5.1.16
The number of packets(good and bad) between 1024 and 1518 octets long
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

statsTotalValidOctets 1.3.6.1.4.1.3955.5.5.1.17
The total number of octets contained in valid frames received on this segment
Status: mandatory Access: read-write
OBJECT-TYPE    
  Counter64  

resetModule 1.3.6.1.4.1.3955.5.5.2.1
Writing any data value to this register is identical to a hardware reset. Everything is reset except the Source Address RAM.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER  

sp2CtlEntry 1.3.6.1.4.1.3955.5.5.2.2
Tok_String
Status: deprecated Access: not-accessible
OBJECT-TYPE    
  Sp2CtlEntry  

ctlHubIdx 1.3.6.1.4.1.3955.5.5.2.2.1
Tok_String
Status: deprecated Access: read-only
OBJECT-TYPE    
  INTEGER  

ctlPortIdx 1.3.6.1.4.1.3955.5.5.2.2.2
Tok_String
Status: deprecated Access: read-only
OBJECT-TYPE    
  INTEGER  

enable 1.3.6.1.4.1.3955.5.5.2.2.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(0), na(-1)  

linkEn 1.3.6.1.4.1.3955.5.5.2.2.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(0), na(-1)  

speedSet 1.3.6.1.4.1.3955.5.5.2.2.5
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER na(-1), nway(0), ether10(1), ether100(3)  

nwayEn 1.3.6.1.4.1.3955.5.5.2.2.6
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(0), na(-1)  

nwayRestart 1.3.6.1.4.1.3955.5.5.2.2.7
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

sp2StEntry 1.3.6.1.4.1.3955.5.5.3.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sp2StEntry  

statHubIdx 1.3.6.1.4.1.3955.5.5.3.1.1
Tok_String
Status: deprecated Access: read-only
OBJECT-TYPE    
  INTEGER  

statPortIdx 1.3.6.1.4.1.3955.5.5.3.1.2
Tok_String
Status: deprecated Access: read-only
OBJECT-TYPE    
  INTEGER  

linkSt 1.3.6.1.4.1.3955.5.5.3.1.3
Indicates every ports' link status.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER na(-1), fail(0), good(1)  

polaritySt 1.3.6.1.4.1.3955.5.5.3.1.4
A read of this register will reflect the current polarity status.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER na(-1), straight(0), cross(1)  

partitionSt 1.3.6.1.4.1.3955.5.5.3.1.5
A read of this register will reflect the current partition status.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER na(-1), yes(0), no(1)  

speedSt 1.3.6.1.4.1.3955.5.5.3.1.6
Indicates the current status of each port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER na(-1), is10M(0), is100M(1)  

nwayPartner 1.3.6.1.4.1.3955.5.5.3.1.7
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER na(-1), no(0), yes(1)  

counterEntry 1.3.6.1.4.1.3955.5.5.4.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  CounterEntry  

cntHubIdx 1.3.6.1.4.1.3955.5.5.4.1.1
A unique value for each family. Its value ranges between 1 and the value of ifNumber. The value for each interface must remain constant at least from one re-initialization of the entity's network management system to the next re- initialization.
Status: deprecated Access: read-only
OBJECT-TYPE    
  INTEGER  

cntPortIdx 1.3.6.1.4.1.3955.5.5.4.1.2
A unique value for each family. Its value ranges between 1 and the value of ifNumber. The value for each interface must remain constant at least from one re-initialization of the entity's network management system to the next re- initialization.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

portReadableFrames 1.3.6.1.4.1.3955.5.5.4.1.3
Counts valid-length, valid-CRC, collision-free packets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

portReadableOctets 1.3.6.1.4.1.3955.5.5.4.1.4
Counts the number of octets in all valid-length, valid-CRC, collision-free packets, not including preamble and framing bits.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter64  

portFrameCheckSequence 1.3.6.1.4.1.3955.5.5.4.1.5
Counts valid length, collision-free packets that had FCS errors, but were correctly framed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

portAlignmentErrors 1.3.6.1.4.1.3955.5.5.4.1.6
Counts valid length, collision-free packets that had FCS errors and were incorrectly framed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

portFramesTooLong 1.3.6.1.4.1.3955.5.5.4.1.7
Counts packets that had a length greater than 1518 octets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

portShortEvents 1.3.6.1.4.1.3955.5.5.4.1.8
Counts events that lasted for 82 bit times or less.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

portRunts 1.3.6.1.4.1.3955.5.5.4.1.9
Counts events longer than 82 bit times, but shorter than 512 bit times
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

portCollisions 1.3.6.1.4.1.3955.5.5.4.1.10
Counts events longer than 82 bit times, but shorter than 512 bit times
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

portLateEvents 1.3.6.1.4.1.3955.5.5.4.1.11
Counts the number of times collisions was detected more than 512 bit times adter the start or carrier
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

portVeryLongEvents 1.3.6.1.4.1.3955.5.5.4.1.12
Counts the number of times any activity continued for more than 4 to 7.5 ms.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

portDataRateMismatches 1.3.6.1.4.1.3955.5.5.4.1.13
Counts the number of times the incoming data rate mis-matched the local clock source enough to cause a FIFO underflow or overflow.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

portAutoPartitions 1.3.6.1.4.1.3955.5.5.4.1.14
Counts the number of times this port has been parti- tioned by the Auto-partition algorithm
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

portTrackSrcAddrChanges 1.3.6.1.4.1.3955.5.5.4.1.15
Counts the number of times the source address has changed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

portBroadcastPkts 1.3.6.1.4.1.3955.5.5.4.1.16
Counts the number of good broadcast packets received by this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

portMulticastPkts 1.3.6.1.4.1.3955.5.5.4.1.17
Counts the number of good multicast packets received by this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter