LIEBERT-UPSTATION-S-UPS-MIB

File: LIEBERT-UPSTATION-S-UPS-MIB.mib (39082 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC1213-MIB
RFC-1215

Imported symbols

enterprises Counter TimeTicks
Gauge OBJECT-TYPE sysUpTime
DisplayString TRAP-TYPE

Defined Types

LcUpsInputEntry  
SEQUENCE    
  lcUpsInputLine INTEGER
  lcUpsInputVoltage INTEGER
  lcUpsInputCurrent INTEGER
  lcUpsInputVA INTEGER

LcUpsOutputEntry  
SEQUENCE    
  lcUpsOutputLine INTEGER
  lcUpsOutputVoltage INTEGER
  lcUpsOutputCurrent INTEGER
  lcUpsOutputVA INTEGER

LcUpsAlarmEntry  
SEQUENCE    
  lcUpsAlarmId INTEGER
  lcUpsAlarmDescr OBJECT IDENTIFIER
  lcUpsAlarmTime TimeTicks

LcUpsSwitchedReceptEntry  
SEQUENCE    
  lcUpsSwitchedReceptIndex INTEGER
  lcUpsSwitchedReceptOnDelay INTEGER
  lcUpsSwitchedReceptOnTrapDelay INTEGER
  lcUpsSwitchedReceptOffDelay INTEGER
  lcUpsSwitchedReceptOffTrapDelay INTEGER
  lcUpsSwitchedReceptStatus INTEGER
  lcUpsSwitchedReceptLabel DisplayString

LsUpsBypassEntry  
SEQUENCE    
  lsUpsBypassLine INTEGER
  lsUpsBypassVoltage INTEGER
  lsUpsBypassCurrent INTEGER

Defined Values

emerson 1.3.6.1.4.1.476
OBJECT IDENTIFIER    

liebertCorp 1.3.6.1.4.1.476.1
OBJECT IDENTIFIER    

liebertUps 1.3.6.1.4.1.476.1.1
OBJECT IDENTIFIER    

luExtensions 1.3.6.1.4.1.476.1.1.1
OBJECT IDENTIFIER    

luExperimental 1.3.6.1.4.1.476.1.1.2
OBJECT IDENTIFIER    

luPrivate 1.3.6.1.4.1.476.1.1.3
OBJECT IDENTIFIER    

luCore 1.3.6.1.4.1.476.1.1.1.1
OBJECT IDENTIFIER    

lcUpsIdent 1.3.6.1.4.1.476.1.1.1.1.1
OBJECT IDENTIFIER    

lcUpsIdentManufacturer 1.3.6.1.4.1.476.1.1.1.1.1.1
The UPS manufacturer.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(255)  

lcUpsIdentModel 1.3.6.1.4.1.476.1.1.1.1.1.2
The UPS Model designation.
Status: optional Access: read-write
OBJECT-TYPE    
  DisplayString Size(255)  

lcUpsIdentSoftwareVersion 1.3.6.1.4.1.476.1.1.1.1.1.3
The UPS SNMP Agent software version.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(255)  

lcUpsIdentSpecific 1.3.6.1.4.1.476.1.1.1.1.1.4
A reference to MIB definitions specific to the particular UPS being managed. This object is used to locate the product-specific MIB for this device. If this information is not present, its value should be the OBJECT IDENTIFIER { 0 0 }, which is a syntactically valid object identifier, and any conformant implementation of ASN.1 and BER must be able to generate and recognize this value.
Status: optional Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

lcUpsBattery 1.3.6.1.4.1.476.1.1.1.1.2
OBJECT IDENTIFIER    

lcUpsBatTimeRemaining 1.3.6.1.4.1.476.1.1.1.1.2.1
The estimated time to depletion of battery charge. (Unit of measure: Minute)
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

lcUpsBatTemperature 1.3.6.1.4.1.476.1.1.1.1.2.2
The battery temperature. (Unit of measure: Degree, Centigrade)
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER -32768..32767  

lcUpsBatVoltage 1.3.6.1.4.1.476.1.1.1.1.2.3
The current battery voltage. (Unit of measure: volt)
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER -32768..32767  

lcUpsBatCurrent 1.3.6.1.4.1.476.1.1.1.1.2.4
The current battery discharging/charging current. (Unit of measure: Amp)
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER -32768..32767  

lcUpsInput 1.3.6.1.4.1.476.1.1.1.1.3
OBJECT IDENTIFIER    

lcUpsInputFrequency 1.3.6.1.4.1.476.1.1.1.1.3.1
The current input frequency. (Unit of measure: Hertz)
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..65536  

lcUpsInputBrownOuts 1.3.6.1.4.1.476.1.1.1.1.3.2
The number of brown-out conditions the UPS has experienced.
Status: optional Access: read-only
OBJECT-TYPE    
  Counter  

lcUpsInputBlackOuts 1.3.6.1.4.1.476.1.1.1.1.3.3
The number of black-out conditions the UPS has experienced.
Status: optional Access: read-only
OBJECT-TYPE    
  Counter  

lcUpsInputTransients 1.3.6.1.4.1.476.1.1.1.1.3.4
The number of transient (surge and spike) conditions the UPS has experienced.
Status: optional Access: read-only
OBJECT-TYPE    
  Counter  

lcUpsInputNumLines 1.3.6.1.4.1.476.1.1.1.1.3.5
The number of input lines utilized in this device. This entry indicates the number of rows in the input table.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 1..3  

lcUpsInputTable 1.3.6.1.4.1.476.1.1.1.1.3.6
Tok_String
Status: optional Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LcUpsInputEntry

lcUpsInputEntry 1.3.6.1.4.1.476.1.1.1.1.3.6.1
Tok_String
Status: optional Access: not-accessible
OBJECT-TYPE    
  LcUpsInputEntry  

lcUpsInputLine 1.3.6.1.4.1.476.1.1.1.1.3.6.1.1
The input Line.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 1..3  

lcUpsInputVoltage 1.3.6.1.4.1.476.1.1.1.1.3.6.1.2
The input voltage. (Unit of measure: Volt)
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..65536  

lcUpsInputCurrent 1.3.6.1.4.1.476.1.1.1.1.3.6.1.3
The input current. (Unit of measure: Amp)
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..65536  

lcUpsInputVA 1.3.6.1.4.1.476.1.1.1.1.3.6.1.4
The input volt-amps.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..2147483647  

lcUpsOutput 1.3.6.1.4.1.476.1.1.1.1.4
OBJECT IDENTIFIER    

lcUpsOutputFrequency 1.3.6.1.4.1.476.1.1.1.1.4.1
The current output frequency. (Unit of measure: Hertz)
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..65536  

lcUpsOutputLoad 1.3.6.1.4.1.476.1.1.1.1.4.2
The current output load percentage.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

lcUpsOutputNumLines 1.3.6.1.4.1.476.1.1.1.1.4.3
The number of output lines utilized in this device. This entry indicates the number of rows in the output table.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 1..3  

lcUpsOutputTable 1.3.6.1.4.1.476.1.1.1.1.4.4
Tok_String
Status: optional Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LcUpsOutputEntry

lcUpsOutputEntry 1.3.6.1.4.1.476.1.1.1.1.4.4.1
Tok_String
Status: optional Access: not-accessible
OBJECT-TYPE    
  LcUpsOutputEntry  

lcUpsOutputLine 1.3.6.1.4.1.476.1.1.1.1.4.4.1.1
The output Line.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 1..3  

lcUpsOutputVoltage 1.3.6.1.4.1.476.1.1.1.1.4.4.1.2
The output voltage. (Unit of measure: Volt)
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..65536  

lcUpsOutputCurrent 1.3.6.1.4.1.476.1.1.1.1.4.4.1.3
The output current. (Unit of measure: Amp)
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..65536  

lcUpsOutputVA 1.3.6.1.4.1.476.1.1.1.1.4.4.1.4
The output volt-amps.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..2147483647  

lcUpsInverter 1.3.6.1.4.1.476.1.1.1.1.5
OBJECT IDENTIFIER    

lcUpsInverterStatus 1.3.6.1.4.1.476.1.1.1.1.5.1
The state of the inverter. Unknown is returned if the state can not be determined.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), on(2), off(3)  

lcUpsInverterTemp 1.3.6.1.4.1.476.1.1.1.1.5.2
The temperature of the inverter. (Unit of measure: degree, Centigrade)
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER -32768..32767  

lcUpsAlarm 1.3.6.1.4.1.476.1.1.1.1.6
OBJECT IDENTIFIER    

lcUpsAlarms 1.3.6.1.4.1.476.1.1.1.1.6.1
The current number of alarm conditions.
Status: optional Access: read-only
OBJECT-TYPE    
  Gauge  

lcUpsAlarmTable 1.3.6.1.4.1.476.1.1.1.1.6.2
Tok_String
Status: optional Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LcUpsAlarmEntry

lcUpsAlarmEntry 1.3.6.1.4.1.476.1.1.1.1.6.2.1
Tok_String
Status: optional Access: not-accessible
OBJECT-TYPE    
  LcUpsAlarmEntry  

lcUpsAlarmId 1.3.6.1.4.1.476.1.1.1.1.6.2.1.1
A unique identifier for an alarm condition. This value must remain constant between agent initializations.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..2147483647  

lcUpsAlarmDescr 1.3.6.1.4.1.476.1.1.1.1.6.2.1.2
A reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition.
Status: optional Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

lcUpsAlarmTime 1.3.6.1.4.1.476.1.1.1.1.6.2.1.3
The value of sysUpTime when the alarm condition occured.
Status: optional Access: read-only
OBJECT-TYPE    
  TimeTicks  

lcUpsAlarmConditions 1.3.6.1.4.1.476.1.1.1.1.6.3
OBJECT IDENTIFIER    

lcUpsAlarmLowBatteryWarning 1.3.6.1.4.1.476.1.1.1.1.6.3.1
OBJECT IDENTIFIER    

lcUpsAlarmLowBatteryShutdown 1.3.6.1.4.1.476.1.1.1.1.6.3.2
OBJECT IDENTIFIER    

lcUpsAlarmUtilFailed 1.3.6.1.4.1.476.1.1.1.1.6.3.3
OBJECT IDENTIFIER    

lcUpsAlarmOverTempWarning 1.3.6.1.4.1.476.1.1.1.1.6.3.4
OBJECT IDENTIFIER    

lcUpsAlarmOutputOverloadWarning 1.3.6.1.4.1.476.1.1.1.1.6.3.6
OBJECT IDENTIFIER    

lcUpsAlarmInputOverVoltage 1.3.6.1.4.1.476.1.1.1.1.6.3.8
OBJECT IDENTIFIER    

lcUpsAlarmBatteryBad 1.3.6.1.4.1.476.1.1.1.1.6.3.9
OBJECT IDENTIFIER    

lcUpsAlarmOnBattery 1.3.6.1.4.1.476.1.1.1.1.6.3.10
OBJECT IDENTIFIER    

lcUpsAlarmUpsOff 1.3.6.1.4.1.476.1.1.1.1.6.3.12
OBJECT IDENTIFIER    

lcUpsTest 1.3.6.1.4.1.476.1.1.1.1.7
OBJECT IDENTIFIER    

lcUpsTestBattery 1.3.6.1.4.1.476.1.1.1.1.7.1
Setting this variable to 'start' will initiate the battery test. Setting this variable to 'abort' will stop the battery test if the test is in- progress, otherwise it has no effect. Setting this variable to 'unknown' has no effect. Reading this variable will always result in a return value of 'unknown'. If 'lcUpsTestBatteryStatus' is 'failed' the test may not be performed again and the status will remain in the failure state.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), start(2), abort(3)  

lcUpsTestBatteryStatus 1.3.6.1.4.1.476.1.1.1.1.7.2
The status of the battery test.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), passed(2), failed(3), inProgress(4), sysFailure(5), notSupported(6), inhibited(7)  

lcUpsTestDiag 1.3.6.1.4.1.476.1.1.1.1.7.3
Setting this variable to 'start' will initiate the diagnostics test. Setting this variable to 'abort' will stop the diagnostics test if the test is in-progress, otherwise it has no effect. Setting this variable to 'unknown' has no effect. Reading this variable will always result in a return value of 'unknown'.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), start(2), abort(3)  

lcUpsTestDiagStatus 1.3.6.1.4.1.476.1.1.1.1.7.4
The status of the diagnostics test.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), passed(2), failed(3), inProgress(4), sysFailure(5), notSupported(6), inhibited(7)  

lcUpsControl 1.3.6.1.4.1.476.1.1.1.1.8
OBJECT IDENTIFIER    

lcUpsControlOutputOffDelay 1.3.6.1.4.1.476.1.1.1.1.8.1
Setting this object causes the agent to instruct the UPS to turn off the output after the indicated number of seconds. The agent counts down the number of seconds until the event will take place. The agent issues an lcUpsOutputOffTrap when the countdown finishes. Note that different models have different clock resolutions, usually greater than 1 second. As a result, the command will only be accurate to the resolution of the UPS's clock. The command can be cancelled by setting lcUpsControlCancelCommand to the value cancel.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER 0..2147483647  

lcUpsControlOutputOnDelay 1.3.6.1.4.1.476.1.1.1.1.8.2
Setting this object causes the agent to instruct the UPS to turn on the output after the indicated number of seconds. The agent counts down the number of seconds until the event will take place. The agent issues an lcUpsOutputOnTrap when the countdown finishes. Note that different models have different clock resolutions, usually greater than 1 second. As a result, the command will only be accurate to the resolution of the UPS's clock. The command can be cancelled by setting lcUpsControlCancelCommand to the value cancel.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER 0..2147483647  

lcUpsControlOutputOffTrapDelay 1.3.6.1.4.1.476.1.1.1.1.8.3
When 'lcUpsControlOutputOffDelay' reaches a value less than or equal to this object's value, an lcUpsOutputOffWarningTrap will be produced and this object will be reset to 0.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER 0..2147483647  

lcUpsControlOutputOnTrapDelay 1.3.6.1.4.1.476.1.1.1.1.8.4
When 'lcUpsControlOutputOnDelay' reaches a value less than or equal to this object's value, an lcUpsOutputOnWarningTrap will be produced and this object will be reset to 0.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER 0..2147483647  

lcUpsControlUnixShutdownDelay 1.3.6.1.4.1.476.1.1.1.1.8.5
Setting this object causes the agent to instruct the UPS to perform a UNIX Shutdown in the indicated number of seconds. The agent counts down the number of seconds until the event will take place. A Unix shutdown is only valid if the UPS is on Battery. During a UNIX Shutdown, the UPS will turn off the output even if the Utility comes back on line before the shutdown time arrives. Note that different models have different clock resolutions, usually greater than 1 second. As a result, the command will only be accurate to the resolution of the UPS's clock. The command can be cancelled by setting lcUpsControlCancelCommand to the value 'cancel'.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER 0..2147483647  

lcUpsControlUnixShutdownTrapDelay 1.3.6.1.4.1.476.1.1.1.1.8.6
When 'lcUpsControlUnixShutdownDelay' reaches a value less than or equal to this object's value, an lcUpsUnixShutdownWarningTrap will be produced and this object will be reset to 0.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER 0..2147483647  

lcUpsControlCancelCommands 1.3.6.1.4.1.476.1.1.1.1.8.7
Setting this variable to 'cancel' will cause the agent to issue instructions to the UPS to cancel all outstanding commands, such as lcUpsControlOutputOff, lcUpsControlOutputOn, lcUpsControlUnixShutdown.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), cancel(2)  

lcUpsControlRebootAgentDelay 1.3.6.1.4.1.476.1.1.1.1.8.8
Setting this object causes the agent to reboot after the indicated number of seconds have expired. The value will count down until the event takes place. The command can be cancelled by setting lcUpsControlCancleCommand to the value cancel.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER 0..2147483647  

lcUpsNominal 1.3.6.1.4.1.476.1.1.1.1.9
OBJECT IDENTIFIER    

lcUpsNominalOutputVoltage 1.3.6.1.4.1.476.1.1.1.1.9.1
The nominal output voltage. (Unit of measure: volt)
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER 0..65536  

lcUpsNominalInputVoltage 1.3.6.1.4.1.476.1.1.1.1.9.2
The nominal input voltage. (Unit of measure: volt)
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER 0..65536  

lcUpsNominalOutputVA 1.3.6.1.4.1.476.1.1.1.1.9.3
The nominal Volt-Amp rating.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER 0..65536  

lcUpsNominalOutputWatts 1.3.6.1.4.1.476.1.1.1.1.9.4
The nominal power rating. (Unit of measure: watt)
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER 0..65536  

lcUpsNominalOutputFreq 1.3.6.1.4.1.476.1.1.1.1.9.5
The nominal output frequency. (Unit of measure: Hertz)
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER 0..65536  

lcUpsNominalInputFreq 1.3.6.1.4.1.476.1.1.1.1.9.6
The nominal input frequency. (Unit of measure: Hertz)
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER 0..65536  

lcUpsSwitchedReceptacles 1.3.6.1.4.1.476.1.1.1.1.12
OBJECT IDENTIFIER    

lcUpsSwitchedReceptMaxNum 1.3.6.1.4.1.476.1.1.1.1.12.1
The maximum number of switched receptacles supported by the Ups.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

lcUpsSwitchedReceptTable 1.3.6.1.4.1.476.1.1.1.1.12.2
Tok_String
Status: optional Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LcUpsSwitchedReceptEntry

lcUpsSwitchedReceptEntry 1.3.6.1.4.1.476.1.1.1.1.12.2.1
Tok_String
Status: optional Access: not-accessible
OBJECT-TYPE    
  LcUpsSwitchedReceptEntry  

lcUpsSwitchedReceptIndex 1.3.6.1.4.1.476.1.1.1.1.12.2.1.1
Tok_String
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

lcUpsSwitchedReceptOnDelay 1.3.6.1.4.1.476.1.1.1.1.12.2.1.2
Setting this object causes the agent to instruct the UPS to turn on a receptacle after the indicated number of seconds. The agent counts down the number of seconds until the event will take place. The agent issues an lcUpsReceptOnTrap when the countdown finishes. Note that different models have different clock resolutions, usually greater than 1 second. As a result, the command will only be accurate to the resolution of the UPS's clock. The command can be cancelled by setting lcUpsSwitchedCancelCommand to the value cancel.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER 0..2147483647  

lcUpsSwitchedReceptOnTrapDelay 1.3.6.1.4.1.476.1.1.1.1.12.2.1.3
When 'lcUpsSwitchedReceptOnDelay' reaches a value less than or equal to this object's value, an lcUpsReceptOnWarningTrap will be produced and this object will be reset to 0.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER 0..2147483647  

lcUpsSwitchedReceptOffDelay 1.3.6.1.4.1.476.1.1.1.1.12.2.1.4
Setting this object causes the agent to instruct the UPS to turn off a receptacle after the indicated number of seconds. The agent counts down the number of seconds until the event will take place. The agent issues an lcUpsReceptOffTrap when the countdown finishes. Note that different models have different clock resolutions, usually greater than 1 second. As a result, the command will only be accurate to the resolution of the UPS's clock. The command can be cancelled by setting lcUpsSwitchedCancelCommand to the value cancel.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER 0..2147483647  

lcUpsSwitchedReceptOffTrapDelay 1.3.6.1.4.1.476.1.1.1.1.12.2.1.5
When 'lcUpsSwitchedReceptOffDelay' reaches a value less than or equal to this object's value, an lcUpsReceptOffWarningTrap will be produced and this object will be reset to 0.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER 0..2147483647  

lcUpsSwitchedReceptStatus 1.3.6.1.4.1.476.1.1.1.1.12.2.1.6
The status of the device receptacle. Note that some devices may support Switched of device receptacles as a group only (by using lcUpsSwitchedOutputOffDelay and lcUpsSwitchedOutputOnDelay).
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

lcUpsSwitchedReceptLabel 1.3.6.1.4.1.476.1.1.1.1.12.2.1.7
A user-defined text string associated with a switched receptacle. This may be used to describe the load powered from the receptacle. The text string is stored in non-volatile memory.
Status: optional Access: read-write
OBJECT-TYPE    
  DisplayString Size(32)  

lcUpsTraps 1.3.6.1.4.1.476.1.1.1.1.11
OBJECT IDENTIFIER    

lcUpsOverloadWarningTrap 1
An lcUpsOverloadWarningTrap signifies that the UPS has detected an Overload condition where the output load has exceeded the UPS's rated capacity.
TRAP-TYPE    

lcUpsOnBatteryTrap 3
An lcUpsOnBatteryTrap signifies that the UPS is currently on Battery Power.
TRAP-TYPE    

lcUpsLowBatteryWarningTrap 4
An lcUpsLowBatteryWarningTrap signifies that the UPS has entered a Low Battery state.
TRAP-TYPE    

lcUpsUtilPowerFailedTrap 6
An lcUpsUtilPowerFailedTrap signifies that the utility power input to the UPS has been lost.
TRAP-TYPE    

lcUpsUtilPowerRestoredTrap 7
An lcUpsUtilPowerRestoredTrap signifies that the utility power has been restored to the UPS.
TRAP-TYPE    

lcUpsInputOverVoltageTrap 8
An lcUpsInputOverVoltageTrap signifies that the UPS has detected a high input voltage condition.
TRAP-TYPE    

lcUpsOverTempWarningTrap 9
An lcUpsOverTempWarningTrap signifies that the UPS has detected a excessive temperature condition.
TRAP-TYPE    

lcUpsAlarmTrap 11
An Alarm condition has occurred and is being reported in the lcUpsAlarmTable.
TRAP-TYPE    

lcUpsOutputOffTrap 12
An lcUpsOutputOffTrap is sent when the UPS turns all of its output off, either at the inverter or via a relay.
TRAP-TYPE    

lcUpsOutputOffWarningTrap 13
An lcUpsOutputOffWarningTrap is sent when the lcUpsControlOutputOffDelay reaches the value of lcUpsControlOutputOffTrapDelay.
TRAP-TYPE    

lcUpsOutputOnTrap 14
An lcUpsOutputOnTrap is sent when the UPS turns all of its output back on, either at the inverter or via a relay.
TRAP-TYPE    

lcUpsOutputOnWarningTrap 15
An lcUpsOutputOnWarningTrap is sent when the lcUpsControlOutputOnDelay reaches the value of lcUpsControlOutputOnTrapDelay.
TRAP-TYPE    

lcUpsUnixShutdownTrap 16
An lcUpsUnixShutodwnTrap is sent 2 seconds before the UPS is scheduled to perform a Unix Shutdown.
TRAP-TYPE    

lcUpsUnixShutdownWarningTrap 17
An lcUpsUnixShutdownWarningTrap is sent when the lcUpsControlUnixShudownDelay reaches the value of lcUpsControlUnixShutdownTrapDelay.
TRAP-TYPE    

lcUpsReceptOffTrap 18
An lcUpsReceptOffTrap is sent when the UPS turns an output receptacle off.
TRAP-TYPE    

lcUpsReceptOffWarningTrap 19
An lcUpsReceptOffWarningTrap is sent when the lcUpsSwitchedReceptOffDelay reaches the value of lcUpsSwitchedReceptOffTrapDelay.
TRAP-TYPE    

lcUpsReceptOnTrap 20
An lcUpsReceptOnTrap is sent when the UPS turns an output receptacle on.
TRAP-TYPE    

lcUpsReceptOnWarningTrap 21
An lcUpsReceptOnWarningTrap is sent when the lcUpsSwitchedReceptOnDelay reaches the value of lcUpsSwitchedReceptOnTrapDelay.
TRAP-TYPE    

luUPStationS 1.3.6.1.4.1.476.1.1.1.2
OBJECT IDENTIFIER    

lsUpsIdent 1.3.6.1.4.1.476.1.1.1.2.1
OBJECT IDENTIFIER    

lsUpsIdentFirmwareVersion 1.3.6.1.4.1.476.1.1.1.2.1.1
The firmware revision level of the UPS.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(255)  

lsUpsAlarm 1.3.6.1.4.1.476.1.1.1.2.6
OBJECT IDENTIFIER    

lsUpsAlarmConditions 1.3.6.1.4.1.476.1.1.1.2.6.1
OBJECT IDENTIFIER    

lsUpsAlarmCheckAirFilter 1.3.6.1.4.1.476.1.1.1.2.6.1.1
OBJECT IDENTIFIER    

lsUpsTraps 1.3.6.1.4.1.476.1.1.1.2.11
OBJECT IDENTIFIER    

lsUpsCheckAirFilterTrap 1
An lsUpsCheckAirFilterTrap signifies that the programmed time interval for checking the air filter has passed and it is time to check the air filter.
TRAP-TYPE    

lsUpsConfig 1.3.6.1.4.1.476.1.1.1.2.12
OBJECT IDENTIFIER    

lsUpsConfigBypassInstalled 1.3.6.1.4.1.476.1.1.1.2.12.1
Indicates if a bypass is installed in the UPS.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), yes(2), no(3)  

lsUpsBypass 1.3.6.1.4.1.476.1.1.1.2.13
OBJECT IDENTIFIER    

lsUpsOnBypass 1.3.6.1.4.1.476.1.1.1.2.13.1
Indicates that the UPS is currently on bypass.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), yes(2), no(3)  

lsUpsBypassFrequency 1.3.6.1.4.1.476.1.1.1.2.13.2
The current bypass frequency. (Unit of measure: Hertz)
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..65536  

lsUpsBypassNumLines 1.3.6.1.4.1.476.1.1.1.2.13.3
The number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 1..3  

lsUpsBypassTable 1.3.6.1.4.1.476.1.1.1.2.13.4
Tok_String
Status: optional Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LsUpsBypassEntry

lsUpsBypassEntry 1.3.6.1.4.1.476.1.1.1.2.13.4.1
Tok_String
Status: optional Access: not-accessible
OBJECT-TYPE    
  LsUpsBypassEntry  

lsUpsBypassLine 1.3.6.1.4.1.476.1.1.1.2.13.4.1.1
The bypass Line.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 1..3  

lsUpsBypassVoltage 1.3.6.1.4.1.476.1.1.1.2.13.4.1.2
The bypass voltage. (Unit of measure: Volt)
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..65536  

lsUpsBypassCurrent 1.3.6.1.4.1.476.1.1.1.2.13.4.1.3
The bypass current. (Unit of measure: Amp)
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..65536