LIEBERT-UPS-MIB

File: LIEBERT-UPS-MIB.mib (71621 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC1213-MIB
RFC-1215

Imported symbols

enterprises Counter TimeTicks
Gauge OBJECT-TYPE sysUpTime
DisplayString TRAP-TYPE

Defined Types

LcUpsInputEntry  
SEQUENCE    
  lcUpsInputLine INTEGER
  lcUpsInputVoltage INTEGER
  lcUpsInputCurrent INTEGER
  lcUpsInputVA INTEGER

LcUpsOutputEntry  
SEQUENCE    
  lcUpsOutputLine INTEGER
  lcUpsOutputVoltage INTEGER
  lcUpsOutputCurrent INTEGER
  lcUpsOutputVA INTEGER

LcUpsAlarmEntry  
SEQUENCE    
  lcUpsAlarmId INTEGER
  lcUpsAlarmDescr OBJECT IDENTIFIER
  lcUpsAlarmTime TimeTicks

LcUpsBypassEntry  
SEQUENCE    
  lcUpsBypassLine INTEGER
  lcUpsBypassVoltage INTEGER
  lcUpsBypassCurrent INTEGER

LcUpsSwitchedReceptEntry  
SEQUENCE    
  lcUpsSwitchedReceptIndex INTEGER
  lcUpsSwitchedReceptOnDelay INTEGER
  lcUpsSwitchedReceptOnTrapDelay INTEGER
  lcUpsSwitchedReceptOffDelay INTEGER
  lcUpsSwitchedReceptOffTrapDelay INTEGER
  lcUpsSwitchedReceptStatus INTEGER
  lcUpsSwitchedReceptLabel DisplayString

LsUpsBypassEntry  
SEQUENCE    
  lsUpsBypassLine INTEGER
  lsUpsBypassVoltage INTEGER
  lsUpsBypassCurrent INTEGER

Ls43cUpsBypassEntry  
SEQUENCE    
  ls43cUpsBypassLine INTEGER
  ls43cUpsBypassVoltage INTEGER
  ls43cUpsBypassCurrent INTEGER

Defined Values

emerson 1.3.6.1.4.1.476
OBJECT IDENTIFIER    

liebertCorp 1.3.6.1.4.1.476.1
OBJECT IDENTIFIER    

liebertUps 1.3.6.1.4.1.476.1.1
OBJECT IDENTIFIER    

luExtensions 1.3.6.1.4.1.476.1.1.1
OBJECT IDENTIFIER    

luExperimental 1.3.6.1.4.1.476.1.1.2
OBJECT IDENTIFIER    

luPrivate 1.3.6.1.4.1.476.1.1.3
OBJECT IDENTIFIER    

luCore 1.3.6.1.4.1.476.1.1.1.1
OBJECT IDENTIFIER    

lcUpsIdent 1.3.6.1.4.1.476.1.1.1.1.1
OBJECT IDENTIFIER    

lcUpsIdentManufacturer 1.3.6.1.4.1.476.1.1.1.1.1.1
The UPS manufacturer.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(255)  

lcUpsIdentModel 1.3.6.1.4.1.476.1.1.1.1.1.2
The UPS Model designation.
Status: optional Access: read-write
OBJECT-TYPE    
  DisplayString Size(255)  

lcUpsIdentSoftwareVersion 1.3.6.1.4.1.476.1.1.1.1.1.3
The UPS SNMP Agent software version.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(255)  

lcUpsIdentSpecific 1.3.6.1.4.1.476.1.1.1.1.1.4
A reference to MIB definitions specific to the particular UPS being managed. This object is used to locate the product-specific MIB for this device. If this information is not present, its value should be the OBJECT IDENTIFIER { 0 0 }, which is a syntactically valid object identifier, and any conformant implementation of ASN.1 and BER must be able to generate and recognize this value.
Status: optional Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

lcUpsIdentFirmwareVersion 1.3.6.1.4.1.476.1.1.1.1.1.5
The firmware revision level of the UPS.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(16)  

lcUpsIdentSerialNumber 1.3.6.1.4.1.476.1.1.1.1.1.6
The serial number of the UPS.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(20)  

lcUpsIdentManufactureDate 1.3.6.1.4.1.476.1.1.1.1.1.7
The date of manufacture of the UPS.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(8)  

lcUpsBattery 1.3.6.1.4.1.476.1.1.1.1.2
OBJECT IDENTIFIER    

lcUpsBatTimeRemaining 1.3.6.1.4.1.476.1.1.1.1.2.1
The estimated time to depletion of battery charge. (Unit of measure: Minute)
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

lcUpsBatTemperature 1.3.6.1.4.1.476.1.1.1.1.2.2
The battery temperature. (Unit of measure: Degree, Centigrade)
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER -32768..32767  

lcUpsBatVoltage 1.3.6.1.4.1.476.1.1.1.1.2.3
The current battery voltage. (Unit of measure: volt)
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER -32768..32767  

lcUpsBatCurrent 1.3.6.1.4.1.476.1.1.1.1.2.4
The current battery discharging/charging current. (Unit of measure: Amp)
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER -32768..32767  

lcUpsBatCapacity 1.3.6.1.4.1.476.1.1.1.1.2.6
The current battery capacity in percentage of total available.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

lcUpsBatTotalDischCounts 1.3.6.1.4.1.476.1.1.1.1.2.7
The number of discharges the UPS has experienced.
Status: optional Access: read-only
OBJECT-TYPE    
  Counter  

lcUpsBatCycleDurationInSeconds 1.3.6.1.4.1.476.1.1.1.1.2.8
The total accumulated discharge time in seconds.
Status: optional Access: read-only
OBJECT-TYPE    
  Counter  

lcUpsBatAmpHours 1.3.6.1.4.1.476.1.1.1.1.2.9
The number of amp hours withdrawn from battery.
Status: optional Access: read-only
OBJECT-TYPE    
  Counter  

lcUpsBatKWhours 1.3.6.1.4.1.476.1.1.1.1.2.10
The number of Kilowatt-hours withdrawn from battery.
Status: optional Access: read-only
OBJECT-TYPE    
  Counter  

lcUpsBatWattHours 1.3.6.1.4.1.476.1.1.1.1.2.11
The number of Watt-hours withdrawn from battery.
Status: optional Access: read-only
OBJECT-TYPE    
  Counter  

lcUpsInput 1.3.6.1.4.1.476.1.1.1.1.3
OBJECT IDENTIFIER    

lcUpsInputFrequency 1.3.6.1.4.1.476.1.1.1.1.3.1
The current input frequency. (Unit of measure: Hertz)
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..65536  

lcUpsInputBrownOuts 1.3.6.1.4.1.476.1.1.1.1.3.2
The number of brown-out conditions the UPS has experienced.
Status: optional Access: read-only
OBJECT-TYPE    
  Counter  

lcUpsInputBlackOuts 1.3.6.1.4.1.476.1.1.1.1.3.3
The number of black-out conditions the UPS has experienced.
Status: optional Access: read-only
OBJECT-TYPE    
  Counter  

lcUpsInputTransients 1.3.6.1.4.1.476.1.1.1.1.3.4
The number of transient (surge and spike) conditions the UPS has experienced.
Status: optional Access: read-only
OBJECT-TYPE    
  Counter  

lcUpsInputNumLines 1.3.6.1.4.1.476.1.1.1.1.3.5
The number of input lines utilized in this device. This entry indicates the number of rows in the input table.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 1..3  

lcUpsInputTable 1.3.6.1.4.1.476.1.1.1.1.3.6
Tok_String
Status: optional Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LcUpsInputEntry

lcUpsInputEntry 1.3.6.1.4.1.476.1.1.1.1.3.6.1
Tok_String
Status: optional Access: not-accessible
OBJECT-TYPE    
  LcUpsInputEntry  

lcUpsInputLine 1.3.6.1.4.1.476.1.1.1.1.3.6.1.1
The input Line.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 1..3  

lcUpsInputVoltage 1.3.6.1.4.1.476.1.1.1.1.3.6.1.2
The input voltage. (Unit of measure: Volt)
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..65536  

lcUpsInputCurrent 1.3.6.1.4.1.476.1.1.1.1.3.6.1.3
The input current. (Unit of measure: Amp)
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..65536  

lcUpsInputVA 1.3.6.1.4.1.476.1.1.1.1.3.6.1.4
The input volt-amps.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..2147483647  

lcUpsOutput 1.3.6.1.4.1.476.1.1.1.1.4
OBJECT IDENTIFIER    

lcUpsOutputFrequency 1.3.6.1.4.1.476.1.1.1.1.4.1
The current output frequency. (Unit of measure: Hertz)
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..65536  

lcUpsOutputLoad 1.3.6.1.4.1.476.1.1.1.1.4.2
The current output load percentage.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

lcUpsOutputNumLines 1.3.6.1.4.1.476.1.1.1.1.4.3
The number of output lines utilized in this device. This entry indicates the number of rows in the output table.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 1..3  

lcUpsOutputTable 1.3.6.1.4.1.476.1.1.1.1.4.4
Tok_String
Status: optional Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LcUpsOutputEntry

lcUpsOutputEntry 1.3.6.1.4.1.476.1.1.1.1.4.4.1
Tok_String
Status: optional Access: not-accessible
OBJECT-TYPE    
  LcUpsOutputEntry  

lcUpsOutputLine 1.3.6.1.4.1.476.1.1.1.1.4.4.1.1
The output Line.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 1..3  

lcUpsOutputVoltage 1.3.6.1.4.1.476.1.1.1.1.4.4.1.2
The output voltage. (Unit of measure: Volt)
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..65536  

lcUpsOutputCurrent 1.3.6.1.4.1.476.1.1.1.1.4.4.1.3
The output current. (Unit of measure: Amp)
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..65536  

lcUpsOutputVA 1.3.6.1.4.1.476.1.1.1.1.4.4.1.4
The output volt-amps.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..2147483647  

lcUpsOutputWatts 1.3.6.1.4.1.476.1.1.1.1.4.5
The output power in watts.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..2147483647  

lcUpsInverter 1.3.6.1.4.1.476.1.1.1.1.5
OBJECT IDENTIFIER    

lcUpsInverterStatus 1.3.6.1.4.1.476.1.1.1.1.5.1
The state of the inverter. Unknown is returned if the state can not be determined.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), on(2), off(3)  

lcUpsInverterTemp 1.3.6.1.4.1.476.1.1.1.1.5.2
The temperature of the inverter. (Unit of measure: degree, Centigrade)
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER -32768..32767  

lcUpsAlarm 1.3.6.1.4.1.476.1.1.1.1.6
OBJECT IDENTIFIER    

lcUpsAlarms 1.3.6.1.4.1.476.1.1.1.1.6.1
The current number of alarm conditions.
Status: optional Access: read-only
OBJECT-TYPE    
  Gauge  

lcUpsAlarmTable 1.3.6.1.4.1.476.1.1.1.1.6.2
Tok_String
Status: optional Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LcUpsAlarmEntry

lcUpsAlarmEntry 1.3.6.1.4.1.476.1.1.1.1.6.2.1
Tok_String
Status: optional Access: not-accessible
OBJECT-TYPE    
  LcUpsAlarmEntry  

lcUpsAlarmId 1.3.6.1.4.1.476.1.1.1.1.6.2.1.1
A unique identifier for an alarm condition. This value must remain constant between agent initializations.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..2147483647  

lcUpsAlarmDescr 1.3.6.1.4.1.476.1.1.1.1.6.2.1.2
A reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition.
Status: optional Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

lcUpsAlarmTime 1.3.6.1.4.1.476.1.1.1.1.6.2.1.3
The value of sysUpTime when the alarm condition occured.
Status: optional Access: read-only
OBJECT-TYPE    
  TimeTicks  

lcUpsAlarmConditions 1.3.6.1.4.1.476.1.1.1.1.6.3
OBJECT IDENTIFIER    

lcUpsAlarmLowBatteryWarning 1.3.6.1.4.1.476.1.1.1.1.6.3.1
OBJECT IDENTIFIER    

lcUpsAlarmLowBatteryShutdown 1.3.6.1.4.1.476.1.1.1.1.6.3.2
OBJECT IDENTIFIER    

lcUpsAlarmUtilFailed 1.3.6.1.4.1.476.1.1.1.1.6.3.3
OBJECT IDENTIFIER    

lcUpsAlarmOverTempWarning 1.3.6.1.4.1.476.1.1.1.1.6.3.4
OBJECT IDENTIFIER    

lcUpsAlarmOverTempShutdown 1.3.6.1.4.1.476.1.1.1.1.6.3.5
OBJECT IDENTIFIER    

lcUpsAlarmOutputOverloadWarning 1.3.6.1.4.1.476.1.1.1.1.6.3.6
OBJECT IDENTIFIER    

lcUpsAlarmOutputOverloadShutdown 1.3.6.1.4.1.476.1.1.1.1.6.3.7
OBJECT IDENTIFIER    

lcUpsAlarmInputOverVoltage 1.3.6.1.4.1.476.1.1.1.1.6.3.8
OBJECT IDENTIFIER    

lcUpsAlarmBatteryBad 1.3.6.1.4.1.476.1.1.1.1.6.3.9
OBJECT IDENTIFIER    

lcUpsAlarmOnBattery 1.3.6.1.4.1.476.1.1.1.1.6.3.10
OBJECT IDENTIFIER    

lcUpsAlarmStopNoticeIssued 1.3.6.1.4.1.476.1.1.1.1.6.3.11
OBJECT IDENTIFIER    

lcUpsAlarmUpsOff 1.3.6.1.4.1.476.1.1.1.1.6.3.12
OBJECT IDENTIFIER    

lcUpsAlarmInputFreqError 1.3.6.1.4.1.476.1.1.1.1.6.3.13
OBJECT IDENTIFIER    

lcUpsAlarmOutputUnderVoltage 1.3.6.1.4.1.476.1.1.1.1.6.3.15
OBJECT IDENTIFIER    

lcUpsAlarmOutputOverVoltage 1.3.6.1.4.1.476.1.1.1.1.6.3.16
OBJECT IDENTIFIER    

lcUpsBadBypassPower 1.3.6.1.4.1.476.1.1.1.1.6.3.17
OBJECT IDENTIFIER    

lcUpsAlarmDCOverVoltageShutdown 1.3.6.1.4.1.476.1.1.1.1.6.3.18
OBJECT IDENTIFIER    

lcUpsAlarmHardwareShutdown 1.3.6.1.4.1.476.1.1.1.1.6.3.23
OBJECT IDENTIFIER    

lcUpsAlarmEmergencyXferToBypass 1.3.6.1.4.1.476.1.1.1.1.6.3.24
OBJECT IDENTIFIER    

lcUpsAlarmInverterFault 1.3.6.1.4.1.476.1.1.1.1.6.3.25
OBJECT IDENTIFIER    

lcUpsAlarmPhaseRotationError 1.3.6.1.4.1.476.1.1.1.1.6.3.26
OBJECT IDENTIFIER    

lcUpsAlarmFuseBlown 1.3.6.1.4.1.476.1.1.1.1.6.3.28
OBJECT IDENTIFIER    

lcUpsAlarmAmbientOverTemp 1.3.6.1.4.1.476.1.1.1.1.6.3.29
OBJECT IDENTIFIER    

lcUpsAlarmEmergencyPowerOff 1.3.6.1.4.1.476.1.1.1.1.6.3.30
OBJECT IDENTIFIER    

lcUpsAlarmFanFailed 1.3.6.1.4.1.476.1.1.1.1.6.3.31
OBJECT IDENTIFIER    

lcUpsAlarmControlPowerFailed 1.3.6.1.4.1.476.1.1.1.1.6.3.32
OBJECT IDENTIFIER    

lcUpsAlarmReversePower 1.3.6.1.4.1.476.1.1.1.1.6.3.33
OBJECT IDENTIFIER    

lcUpsAlarmDCgroundFault 1.3.6.1.4.1.476.1.1.1.1.6.3.34
OBJECT IDENTIFIER    

lcUpsAlarmLoadOnBypass 1.3.6.1.4.1.476.1.1.1.1.6.3.35
OBJECT IDENTIFIER    

lcUpsAlarmBatteryCbOpen 1.3.6.1.4.1.476.1.1.1.1.6.3.37
OBJECT IDENTIFIER    

lcUpsAlarmInputCbOpen 1.3.6.1.4.1.476.1.1.1.1.6.3.38
OBJECT IDENTIFIER    

lcUpsAlarmOutputCbOpen 1.3.6.1.4.1.476.1.1.1.1.6.3.39
OBJECT IDENTIFIER    

lcUpsAlarmOutputFreqError 1.3.6.1.4.1.476.1.1.1.1.6.3.40
OBJECT IDENTIFIER    

lcUpsAlarmStaticSwUnable 1.3.6.1.4.1.476.1.1.1.1.6.3.41
OBJECT IDENTIFIER    

lcUpsAlarmManualResetXfer 1.3.6.1.4.1.476.1.1.1.1.6.3.42
OBJECT IDENTIFIER    

lcUpsAlarmAutoRexferPrimed 1.3.6.1.4.1.476.1.1.1.1.6.3.43
OBJECT IDENTIFIER    

lcUpsAlarmBattCycleBuffWarn 1.3.6.1.4.1.476.1.1.1.1.6.3.44
OBJECT IDENTIFIER    

lcUpsAlarmModuleSummary 1.3.6.1.4.1.476.1.1.1.1.6.3.45
OBJECT IDENTIFIER    

lcUpsLineCorrectionActive 1.3.6.1.4.1.476.1.1.1.1.6.3.46
OBJECT IDENTIFIER    

lcUpsTest 1.3.6.1.4.1.476.1.1.1.1.7
OBJECT IDENTIFIER    

lcUpsTestBattery 1.3.6.1.4.1.476.1.1.1.1.7.1
Setting this variable to 'start' will initiate the battery test. Setting this variable to 'abort' will stop the battery test if the test is in- progress, otherwise it has no effect. Setting this variable to 'unknown' has no effect. Reading this variable will always result in a return value of 'unknown'. If 'lcUpsTestBatteryStatus' is 'failed' the test may not be performed again and the status will remain in the failure state.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), start(2), abort(3)  

lcUpsTestBatteryStatus 1.3.6.1.4.1.476.1.1.1.1.7.2
The status of the battery test.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), passed(2), failed(3), inProgress(4), sysFailure(5), notSupported(6), inhibited(7)  

lcUpsTestDiag 1.3.6.1.4.1.476.1.1.1.1.7.3
Setting this variable to 'start' will initiate the diagnostics test. Setting this variable to 'abort' will stop the diagnostics test if the test is in-progress, otherwise it has no effect. Setting this variable to 'unknown' has no effect. Reading this variable will always result in a return value of 'unknown'.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), start(2), abort(3)  

lcUpsTestDiagStatus 1.3.6.1.4.1.476.1.1.1.1.7.4
The status of the diagnostics test.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), passed(2), failed(3), inProgress(4), sysFailure(5), notSupported(6), inhibited(7)  

lcUpsControl 1.3.6.1.4.1.476.1.1.1.1.8
OBJECT IDENTIFIER    

lcUpsControlOutputOffDelay 1.3.6.1.4.1.476.1.1.1.1.8.1
Setting this object causes the agent to instruct the UPS to turn off the output after the indicated number of seconds. The agent counts down the number of seconds until the event will take place. The agent issues an lcUpsOutputOffTrap when the countdown finishes. Note that different models have different clock resolutions, usually greater than 1 second. As a result, the command will only be accurate to the resolution of the UPS's clock. The command can be cancelled by setting lcUpsControlCancelCommand to the value cancel.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER 0..2147483647  

lcUpsControlOutputOnDelay 1.3.6.1.4.1.476.1.1.1.1.8.2
Setting this object causes the agent to instruct the UPS to turn on the output after the indicated number of seconds. The agent counts down the number of seconds until the event will take place. The agent issues an lcUpsOutputOnTrap when the countdown finishes. Note that different models have different clock resolutions, usually greater than 1 second. As a result, the command will only be accurate to the resolution of the UPS's clock. The command can be cancelled by setting lcUpsControlCancelCommand to the value cancel.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER 0..2147483647  

lcUpsControlOutputOffTrapDelay 1.3.6.1.4.1.476.1.1.1.1.8.3
When 'lcUpsControlOutputOffDelay' reaches a value less than or equal to this object's value, an lcUpsOutputOffWarningTrap will be produced and this object will be reset to 0.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER 0..2147483647  

lcUpsControlOutputOnTrapDelay 1.3.6.1.4.1.476.1.1.1.1.8.4
When 'lcUpsControlOutputOnDelay' reaches a value less than or equal to this object's value, an lcUpsOutputOnWarningTrap will be produced and this object will be reset to 0.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER 0..2147483647  

lcUpsControlUnixShutdownDelay 1.3.6.1.4.1.476.1.1.1.1.8.5
Setting this object causes the agent to instruct the UPS to perform a UNIX Shutdown in the indicated number of seconds. The agent counts down the number of seconds until the event will take place. A Unix shutdown is only valid if the UPS is on Battery. During a UNIX Shutdown, the UPS will turn off the output even if the Utility comes back on line before the shutdown time arrives. Note that different models have different clock resolutions, usually greater than 1 second. As a result, the command will only be accurate to the resolution of the UPS's clock. The command can be cancelled by setting lcUpsControlCancelCommand to the value 'cancel'.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER 0..2147483647  

lcUpsControlUnixShutdownTrapDelay 1.3.6.1.4.1.476.1.1.1.1.8.6
When 'lcUpsControlUnixShutdownDelay' reaches a value less than or equal to this object's value, an lcUpsUnixShutdownWarningTrap will be produced and this object will be reset to 0.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER 0..2147483647  

lcUpsControlCancelCommands 1.3.6.1.4.1.476.1.1.1.1.8.7
Setting this variable to 'cancel' will cause the agent to issue instructions to the UPS to cancel all outstanding commands, such as lcUpsControlOutputOff, lcUpsControlOutputOn, lcUpsControlUnixShutdown.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), cancel(2)  

lcUpsControlRebootAgentDelay 1.3.6.1.4.1.476.1.1.1.1.8.8
Setting this object causes the agent to reboot after the indicated number of seconds have expired. The value will count down until the event takes place.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER 0..2147483647  

lcUpsNominal 1.3.6.1.4.1.476.1.1.1.1.9
OBJECT IDENTIFIER    

lcUpsNominalOutputVoltage 1.3.6.1.4.1.476.1.1.1.1.9.1
The nominal output voltage. (Unit of measure: volt)
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER 0..65536  

lcUpsNominalInputVoltage 1.3.6.1.4.1.476.1.1.1.1.9.2
The nominal input voltage. (Unit of measure: volt)
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER 0..65536  

lcUpsNominalOutputVA 1.3.6.1.4.1.476.1.1.1.1.9.3
The nominal Volt-Amp rating.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER 0..65536  

lcUpsNominalOutputWatts 1.3.6.1.4.1.476.1.1.1.1.9.4
The nominal power rating. (Unit of measure: watt)
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER 0..65536  

lcUpsNominalOutputFreq 1.3.6.1.4.1.476.1.1.1.1.9.5
The nominal output frequency. (Unit of measure: Hertz)
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER 0..65536  

lcUpsNominalInputFreq 1.3.6.1.4.1.476.1.1.1.1.9.6
The nominal input frequency. (Unit of measure: Hertz)
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER 0..65536  

lcUpsNominalOutputVaRating 1.3.6.1.4.1.476.1.1.1.1.9.7
The nominal Volt-Amp rating.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER 0..2147483647  

lcUpsNominalOutputWattsRating 1.3.6.1.4.1.476.1.1.1.1.9.8
The nominal power rating. (Unit of measure: watt)
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER 0..2147483647  

lcUpsBypass 1.3.6.1.4.1.476.1.1.1.1.13
OBJECT IDENTIFIER    

lcUpsOnBypass 1.3.6.1.4.1.476.1.1.1.1.13.1
Indicates that the UPS is currently on bypass.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), yes(2), no(3), maintenance(4)  

lcUpsBypassFrequency 1.3.6.1.4.1.476.1.1.1.1.13.2
The current bypass frequency. (Unit of measure: Hertz)
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..65536  

lcUpsBypassNumLines 1.3.6.1.4.1.476.1.1.1.1.13.3
The number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 1..3  

lcUpsBypassTable 1.3.6.1.4.1.476.1.1.1.1.13.4
Tok_String
Status: optional Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LcUpsBypassEntry

lcUpsBypassEntry 1.3.6.1.4.1.476.1.1.1.1.13.4.1
Tok_String
Status: optional Access: not-accessible
OBJECT-TYPE    
  LcUpsBypassEntry  

lcUpsBypassLine 1.3.6.1.4.1.476.1.1.1.1.13.4.1.1
The bypass Line.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 1..3  

lcUpsBypassVoltage 1.3.6.1.4.1.476.1.1.1.1.13.4.1.2
The bypass voltage. (Unit of measure: Volt)
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..65536  

lcUpsBypassCurrent 1.3.6.1.4.1.476.1.1.1.1.13.4.1.3
The bypass current. (Unit of measure: Amp)
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..65536  

lcUpsConfig 1.3.6.1.4.1.476.1.1.1.1.14
OBJECT IDENTIFIER    

lcUpsConfigType 1.3.6.1.4.1.476.1.1.1.1.14.1
Indicates the UPS topology.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), online(2), offline(3), lineinteractive(4)  

lcUpsConfigBypassInstalled 1.3.6.1.4.1.476.1.1.1.1.14.2
Indicates if a bypass is installed in the UPS.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), yes(2), no(3), dualinput(4)  

lcUpsConfigModuleCount 1.3.6.1.4.1.476.1.1.1.1.14.3
A number identifying how many multi-module UPS are connected to the System Control Cabinet.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..16  

lcUpsConfigCurrentModule 1.3.6.1.4.1.476.1.1.1.1.14.4
A number identifying which module of a multi-module UPS is currently being monitored.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER 0..16  

lcUpsConfigAudibleStatus 1.3.6.1.4.1.476.1.1.1.1.14.5
The requested state of the audible alarm. When in the disabled state, the audible alarm should never sound. The enabled state is self-describing. Setting this object to muted(3) when the audible alarm is sounding shall temporarily silence the alarm.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2), muted(3)  

lcUpsConfigLowBattTime 1.3.6.1.4.1.476.1.1.1.1.14.6
The value of lcUpsBatTimeRemaining at which a lowBatteryWarning condition is declared. (Unit of measure: Minute)
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

lcUpsConfigAutoRestart 1.3.6.1.4.1.476.1.1.1.1.14.7
Setting this object will start the output after the indicated number of ticks (1 tick = 10 seconds), including starting the UPS, if necessary. Setting this object to 0 will cause the startup to occur immediately. Setting this object to -1 will disable autorestart.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER -1..32767  

lcUpsSwitchedReceptacles 1.3.6.1.4.1.476.1.1.1.1.12
OBJECT IDENTIFIER    

lcUpsSwitchedReceptMaxNum 1.3.6.1.4.1.476.1.1.1.1.12.1
The maximum number of switched receptacles supported by the Ups.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

lcUpsSwitchedReceptTable 1.3.6.1.4.1.476.1.1.1.1.12.2
Tok_String
Status: optional Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LcUpsSwitchedReceptEntry

lcUpsSwitchedReceptEntry 1.3.6.1.4.1.476.1.1.1.1.12.2.1
Tok_String
Status: optional Access: not-accessible
OBJECT-TYPE    
  LcUpsSwitchedReceptEntry  

lcUpsSwitchedReceptIndex 1.3.6.1.4.1.476.1.1.1.1.12.2.1.1
Tok_String
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

lcUpsSwitchedReceptOnDelay 1.3.6.1.4.1.476.1.1.1.1.12.2.1.2
Setting this object causes the agent to instruct the UPS to turn on a receptacle after the indicated number of seconds. The agent counts down the number of seconds until the event will take place. The agent issues an lcUpsReceptOnTrap when the countdown finishes. Note that different models have different clock resolutions, usually greater than 1 second. As a result, the command will only be accurate to the resolution of the UPS's clock. The command can be cancelled by setting lcUpsSwitchedCancelCommand to the value cancel.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER 0..2147483647  

lcUpsSwitchedReceptOnTrapDelay 1.3.6.1.4.1.476.1.1.1.1.12.2.1.3
When 'lcUpsSwitchedReceptOnDelay' reaches a value less than or equal to this object's value, an lcUpsReceptOnWarningTrap will be produced and this object will be reset to 0.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER 0..2147483647  

lcUpsSwitchedReceptOffDelay 1.3.6.1.4.1.476.1.1.1.1.12.2.1.4
Setting this object causes the agent to instruct the UPS to turn off a receptacle after the indicated number of seconds. The agent counts down the number of seconds until the event will take place. The agent issues an lcUpsReceptOffTrap when the countdown finishes. Note that different models have different clock resolutions, usually greater than 1 second. As a result, the command will only be accurate to the resolution of the UPS's clock. The command can be cancelled by setting lcUpsSwitchedCancelCommand to the value cancel.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER 0..2147483647  

lcUpsSwitchedReceptOffTrapDelay 1.3.6.1.4.1.476.1.1.1.1.12.2.1.5
When 'lcUpsSwitchedReceptOffDelay' reaches a value less than or equal to this object's value, an lcUpsReceptOffWarningTrap will be produced and this object will be reset to 0.
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER 0..2147483647  

lcUpsSwitchedReceptStatus 1.3.6.1.4.1.476.1.1.1.1.12.2.1.6
The status of the device receptacle. Note that some devices may support Switched of device receptacles as a group only (by using lcUpsSwitchedOutputOffDelay and lcUpsSwitchedOutputOnDelay).
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

lcUpsSwitchedReceptLabel 1.3.6.1.4.1.476.1.1.1.1.12.2.1.7
A user-defined text string associated with a switched receptacle. This may be used to describe the load powered from the receptacle. The text string is stored in non-volatile memory.
Status: optional Access: read-write
OBJECT-TYPE    
  DisplayString Size(32)  

lcUpsTraps 1.3.6.1.4.1.476.1.1.1.1.11
OBJECT IDENTIFIER    

lcUpsOverloadWarningTrap 1
An lcUpsOverloadWarningTrap signifies that the UPS has detected an Overload condition where the output load has exceeded the UPS's rated capacity.
TRAP-TYPE    

lcUpsOverloadShutdownTrap 2
An lcUpsOverloadShutdownTrap signifies that the UPS has detected an Overload condition where the output load has exceeded the UPS's rated capacity and has shut off the output.
TRAP-TYPE    

lcUpsOnBatteryTrap 3
An lcUpsOnBatteryTrap signifies that the UPS is currently on Battery Power.
TRAP-TYPE    

lcUpsLowBatteryWarningTrap 4
An lcUpsLowBatteryWarningTrap signifies that the UPS has entered a Low Battery state.
TRAP-TYPE    

lcUpsLowBatteryShutdownTrap 5
An lcUpsLowBatteryShutdownTrap signifies that the UPS has shut off the output due to a Low Battery state.
TRAP-TYPE    

lcUpsUtilPowerFailedTrap 6
An lcUpsUtilPowerFailedTrap signifies that the utility power input to the UPS has been lost.
TRAP-TYPE    

lcUpsUtilPowerRestoredTrap 7
An lcUpsUtilPowerRestoredTrap signifies that the utility power has been restored to the UPS.
TRAP-TYPE    

lcUpsInputOverVoltageTrap 8
An lcUpsInputOverVoltageTrap signifies that the UPS has detected a high input voltage condition.
TRAP-TYPE    

lcUpsOverTempWarningTrap 9
An lcUpsOverTempWarningTrap signifies that the UPS has detected a excessive temperature condition.
TRAP-TYPE    

lcUpsOverTempShutdownTrap 10
An lcUpsOverTempShutdownTrap signifies that the UPS has detected a excessive temperature condition and shut off the output.
TRAP-TYPE    

lcUpsAlarmTrap 11
An Alarm condition has occurred and is being reported in the lcUpsAlarmTable.
TRAP-TYPE    

lcUpsOutputOffTrap 12
An lcUpsOutputOffTrap is sent when the UPS turns all of its output off, either at the inverter or via a relay.
TRAP-TYPE    

lcUpsOutputOffWarningTrap 13
An lcUpsOutputOffWarningTrap is sent when the lcUpsControlOutputOffDelay reaches the value of lcUpsControlOutputOffTrapDelay.
TRAP-TYPE    

lcUpsOutputOnTrap 14
An lcUpsOutputOnTrap is sent when the UPS turns all of its output back on, either at the inverter or via a relay.
TRAP-TYPE    

lcUpsOutputOnWarningTrap 15
An lcUpsOutputOnWarningTrap is sent when the lcUpsControlOutputOnDelay reaches the value of lcUpsControlOutputOnTrapDelay.
TRAP-TYPE    

lcUpsUnixShutdownTrap 16
An lcUpsUnixShutodwnTrap is sent 2 seconds before the UPS is scheduled to perform a Unix Shutdown.
TRAP-TYPE    

lcUpsUnixShutdownWarningTrap 17
An lcUpsUnixShutdownWarningTrap is sent when the lcUpsControlUnixShudownDelay reaches the value of lcUpsControlUnixShutdownTrapDelay.
TRAP-TYPE    

lcUpsInputFreqErrorTrap 22
An ldUpsInputFreqErrorTrap signifies that the UPS has detected that input frequency is outside tolerable variance.
TRAP-TYPE    

lcUpsDCOverVoltageShutdownTrap 23
An lcUpsDCOverVoltageShutdownTrap signifies that the UPS has detected that battery voltage is over the tolarable level.
TRAP-TYPE    

lcUpsOutputOverVoltageTrap 24
An lcUpsOutputOverVoltageTrap signifies that the UPS has detected that the output voltage is too high.
TRAP-TYPE    

lcUpsFuseBlownTrap 25
An lcUpsFuseBlownTrap is sent when the UPS's rectifier or DC capacitor fuse has failed.
TRAP-TYPE    

lcUpsEmergencyPowerOffTrap 26
An lcUpsEmergencyPowerOffTrap signifies that the UPS has shut off output due to an emergency condition.
TRAP-TYPE    

lcUpsControlPowerFailureTrap 27
An lcUpsControlPowerFailureTrap signifies a failure in the secondary control power.
TRAP-TYPE    

lcUpsReversePowerTrap 28
An lcUpsReversePowerTrap signifies that output has been shut off due to a reverse power flow condition.
TRAP-TYPE    

lcUpsPhaseRotationErrorTrap 29
An lcUpsPhaseRotationErrorTrap signifies a phase-rotation error in the bypass power.
TRAP-TYPE    

lcUpsLoadOnBypassTrap 30
An lcUpsLoadOnBypassTrap signifies that the load has been transferred to bypass power.
TRAP-TYPE    

lcUpsEmergencyXferToBypassTrap 31
An lcUpsEmergencyXferToBypassTrap signifies that the UPS has automatically tranferred the load to bypass power.
TRAP-TYPE    

lcUpsInverterFaultTrap 34
An lcUpsInverterFaultTrap signifies that the UPS detected a problem with the Inverter.
TRAP-TYPE    

lcUpsReceptOffTrap 18
An lcUpsReceptOffTrap is sent when the UPS turns an output receptacle off.
TRAP-TYPE    

lcUpsReceptOffWarningTrap 19
An lcUpsReceptOffWarningTrap is sent when the lcUpsSwitchedReceptOffDelay reaches the value of lcUpsSwitchedReceptOffTrapDelay.
TRAP-TYPE    

lcUpsReceptOnTrap 20
An lcUpsReceptOnTrap is sent when the UPS turns an output receptacle on.
TRAP-TYPE    

lcUpsReceptOnWarningTrap 21
An lcUpsReceptOnWarningTrap is sent when the lcUpsSwitchedReceptOnDelay reaches the value of lcUpsSwitchedReceptOnTrapDelay.
TRAP-TYPE    

luUPStationS 1.3.6.1.4.1.476.1.1.1.2
OBJECT IDENTIFIER    

lsUpsIdent 1.3.6.1.4.1.476.1.1.1.2.1
OBJECT IDENTIFIER    

lsUpsIdentFirmwareVersion 1.3.6.1.4.1.476.1.1.1.2.1.1
The firmware revision level of the UPS.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(255)  

lsUpsAlarm 1.3.6.1.4.1.476.1.1.1.2.6
OBJECT IDENTIFIER    

lsUpsAlarmConditions 1.3.6.1.4.1.476.1.1.1.2.6.1
OBJECT IDENTIFIER    

lsUpsAlarmCheckAirFilter 1.3.6.1.4.1.476.1.1.1.2.6.1.1
OBJECT IDENTIFIER    

lsUpsTraps 1.3.6.1.4.1.476.1.1.1.2.11
OBJECT IDENTIFIER    

lsUpsCheckAirFilterTrap 1
An lsUpsCheckAirFilterTrap signifies that the programmed time interval for checking the air filter has passed and it is time to check the air filter.
TRAP-TYPE    

lsUpsConfig 1.3.6.1.4.1.476.1.1.1.2.12
OBJECT IDENTIFIER    

lsUpsConfigBypassInstalled 1.3.6.1.4.1.476.1.1.1.2.12.1
Indicates if a bypass is installed in the UPS.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), yes(2), no(3)  

lsUpsBypass 1.3.6.1.4.1.476.1.1.1.2.13
OBJECT IDENTIFIER    

lsUpsOnBypass 1.3.6.1.4.1.476.1.1.1.2.13.1
Indicates that the UPS is currently on bypass.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), yes(2), no(3)  

lsUpsBypassFrequency 1.3.6.1.4.1.476.1.1.1.2.13.2
The current bypass frequency. (Unit of measure: Hertz)
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..65536  

lsUpsBypassNumLines 1.3.6.1.4.1.476.1.1.1.2.13.3
The number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 1..3  

lsUpsBypassTable 1.3.6.1.4.1.476.1.1.1.2.13.4
Tok_String
Status: optional Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LsUpsBypassEntry

lsUpsBypassEntry 1.3.6.1.4.1.476.1.1.1.2.13.4.1
Tok_String
Status: optional Access: not-accessible
OBJECT-TYPE    
  LsUpsBypassEntry  

lsUpsBypassLine 1.3.6.1.4.1.476.1.1.1.2.13.4.1.1
The bypass Line.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 1..3  

lsUpsBypassVoltage 1.3.6.1.4.1.476.1.1.1.2.13.4.1.2
The bypass voltage. (Unit of measure: Volt)
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..65536  

lsUpsBypassCurrent 1.3.6.1.4.1.476.1.1.1.2.13.4.1.3
The bypass current. (Unit of measure: Amp)
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..65536  

luUPStationD 1.3.6.1.4.1.476.1.1.1.3
OBJECT IDENTIFIER    

ldUpsAlarm 1.3.6.1.4.1.476.1.1.1.3.6
OBJECT IDENTIFIER    

ldUpsAlarmConditions 1.3.6.1.4.1.476.1.1.1.3.6.1
OBJECT IDENTIFIER    

ldUpsAlarmDCOverVoltageShutdown 1.3.6.1.4.1.476.1.1.1.3.6.1.1
OBJECT IDENTIFIER    

ldUpsAlarmOutputShortShutdown 1.3.6.1.4.1.476.1.1.1.3.6.1.2
OBJECT IDENTIFIER    

ldUpsAlarmLNReversedShutdown 1.3.6.1.4.1.476.1.1.1.3.6.1.3
OBJECT IDENTIFIER    

ldUpsAlarmImminentShutdown 1.3.6.1.4.1.476.1.1.1.3.6.1.4
OBJECT IDENTIFIER    

ldUpsAlarmInputFreqError 1.3.6.1.4.1.476.1.1.1.3.6.1.5
OBJECT IDENTIFIER    

ldUpsAlarmBoostOn 1.3.6.1.4.1.476.1.1.1.3.6.1.6
OBJECT IDENTIFIER    

ldUpsAlarmReplaceBattery 1.3.6.1.4.1.476.1.1.1.3.6.1.7
OBJECT IDENTIFIER    

ldUpsAlarmOutputOverVoltage 1.3.6.1.4.1.476.1.1.1.3.6.1.8
OBJECT IDENTIFIER    

ldUpsAlarmOutputUnderVoltage 1.3.6.1.4.1.476.1.1.1.3.6.1.9
OBJECT IDENTIFIER    

ldUpsAlarmChargerFailed 1.3.6.1.4.1.476.1.1.1.3.6.1.10
OBJECT IDENTIFIER    

ldUpsTraps 1.3.6.1.4.1.476.1.1.1.3.11
OBJECT IDENTIFIER    

ldUpsDCOverVoltageShutdownTrap 1
An ldUpsDCOverVoltageShutdownTrap signifies that the UPS has detected that battery voltage is over the tolarable level.
TRAP-TYPE    

ldUpsOutputShortShutdownTrap 2
An ldUpsOutputShortShutdownTrap signifies that the UPS has detected a short circuit across the output.
TRAP-TYPE    

ldUpsLNReversedShutdownTrap 3
An ldUpsLNReversedShutdownTrap signifies that the UPS has detected that Line and Neutral have been reversed.
TRAP-TYPE    

ldUpsImminentShutdownTrap 4
An ldUpsImminentShutdownTrap signifies that the UPS is about to turn off output power.
TRAP-TYPE    

ldUpsInputFreqErrorTrap 5
An ldUpsInputFreqErrorTrap signifies that the UPS has detected that input frequency is outside tolerable variance.
TRAP-TYPE    

ldUpsOutputOverVoltageTrap 6
An ldUpsOutputOverVoltageTrap signifies that the UPS has detected that the output voltage is too high.
TRAP-TYPE    

ldUpsOutputUnderVoltageTrap 7
An ldUpsOutputUnderVoltageTrap signifies that the UPS has detected that the output voltage is too low.
TRAP-TYPE    

ldUpsChargerFailedTrap 8
An ldUpsChargerFailedTrap signifies that the UPS has detected that the battery charger has failed.
TRAP-TYPE    

ldUpsInput 1.3.6.1.4.1.476.1.1.1.3.3
OBJECT IDENTIFIER    

ldUpsInputMaxVoltsSinceLastPoll 1.3.6.1.4.1.476.1.1.1.3.3.1
The maximum input voltage encountered since the object was last retrieved. Note: if there are multiple managers talking to the same agent, the use of this object needs to be coordinated.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..65536  

ldUpsInputMinVoltsSinceLastPoll 1.3.6.1.4.1.476.1.1.1.3.3.2
The minimum input voltage encountered since the object was last retrieved. Note: if there are multiple managers talking to the same agent, the use of this object needs to be coordinated.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..65536  

ldUpsOutput 1.3.6.1.4.1.476.1.1.1.3.4
OBJECT IDENTIFIER    

ldUpsOutputMaxVoltsSinceLastPoll 1.3.6.1.4.1.476.1.1.1.3.4.1
The maximum output voltage encountered since the object was last retrieved. Note: if there are multiple managers talking to the same agent, the use of this object needs to be coordinated.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..65536  

ldUpsOutputMinVoltsSinceLastPoll 1.3.6.1.4.1.476.1.1.1.3.4.2
The minimum output voltage encountered since the object was last retrieved. Note: if there are multiple managers talking to the same agent, the use of this object needs to be coordinated.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..65536  

luUPStationG 1.3.6.1.4.1.476.1.1.1.4
OBJECT IDENTIFIER    

lgUpsAlarm 1.3.6.1.4.1.476.1.1.1.4.6
OBJECT IDENTIFIER    

lgUpsAlarmConditions 1.3.6.1.4.1.476.1.1.1.4.6.1
OBJECT IDENTIFIER    

lgUpsAlarmDCOverVoltageShutdown 1.3.6.1.4.1.476.1.1.1.4.6.1.1
OBJECT IDENTIFIER    

lgUpsAlarmOutputShortShutdown 1.3.6.1.4.1.476.1.1.1.4.6.1.2
OBJECT IDENTIFIER    

lgUpsAlarmLNReversedShutdown 1.3.6.1.4.1.476.1.1.1.4.6.1.3
OBJECT IDENTIFIER    

lgUpsAlarmRemoteShutdown 1.3.6.1.4.1.476.1.1.1.4.6.1.4
OBJECT IDENTIFIER    

lgUpsAlarmInputUVOnStartup 1.3.6.1.4.1.476.1.1.1.4.6.1.5
OBJECT IDENTIFIER    

lgUpsAlarmPFCFailedOnStartup 1.3.6.1.4.1.476.1.1.1.4.6.1.6
OBJECT IDENTIFIER    

lgUpsTraps 1.3.6.1.4.1.476.1.1.1.4.11
OBJECT IDENTIFIER    

lgUpsDCOverVoltageShutdownTrap 1
An lgUpsDCOverVoltageShutdownTrap signifies that the UPS has detected that battery voltage is over the nominal level.
TRAP-TYPE    

lgUpsOutputShortShutdownTrap 2
An lgUpsOutputShortShutdownTrap signifies that the UPS has detected a short circuit across the output.
TRAP-TYPE    

lgUpsLNReversedShutdownTrap 3
An lgUpsLNReversedShutdownTrap signifies that the UPS has detected that Line and Neutral have been reversed.
TRAP-TYPE    

lgUpsInputUVOnStartupTrap 4
An lgUpsInputUVOnStartupTrap signifies that the UPS detected a low voltage condition upon system startup.
TRAP-TYPE    

luSeries200 1.3.6.1.4.1.476.1.1.1.8
OBJECT IDENTIFIER    

luSeries200Alarm 1.3.6.1.4.1.476.1.1.1.8.6
OBJECT IDENTIFIER    

luSeries200AlarmConditions 1.3.6.1.4.1.476.1.1.1.8.6.1
OBJECT IDENTIFIER    

luSeries200AlarmInputFreqError 1.3.6.1.4.1.476.1.1.1.8.6.1.1
OBJECT IDENTIFIER    

luSeries200Input 1.3.6.1.4.1.476.1.1.1.8.3
OBJECT IDENTIFIER    

luSeries200InputMaxVoltsSinceLastPoll 1.3.6.1.4.1.476.1.1.1.8.3.1
The maximum input voltage encountered since the object was last retrieved. Note: if there are multiple managers talking to the same agent, the use of this object needs to be coordinated.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..65536  

luSeries200InputMinVoltsSinceLastPoll 1.3.6.1.4.1.476.1.1.1.8.3.2
The minimum input voltage encountered since the object was last retrieved. Note: if there are multiple managers talking to the same agent, the use of this object needs to be coordinated.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..65536  

luSeries200Config 1.3.6.1.4.1.476.1.1.1.8.12
OBJECT IDENTIFIER    

luSeries200ConfigBypassInstalled 1.3.6.1.4.1.476.1.1.1.8.12.1
Indicates if a bypass is installed in the UPS.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), yes(2), no(3)  

luSeries200ConfigFrequencyChangerModel 1.3.6.1.4.1.476.1.1.1.8.12.2
Indicates whether this AP200 model is a frequency changer model.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), yes(2), no(3)  

luSeries200Bypass 1.3.6.1.4.1.476.1.1.1.8.13
OBJECT IDENTIFIER    

luSeries200OnBypass 1.3.6.1.4.1.476.1.1.1.8.13.1
Indicates that the UPS is currently on bypass.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), yes(2), no(3)  

luSeries4300 1.3.6.1.4.1.476.1.1.1.10
OBJECT IDENTIFIER    

ls43cUpsIdent 1.3.6.1.4.1.476.1.1.1.10.1
OBJECT IDENTIFIER    

ls43cUpsIdentFirmwareVersion 1.3.6.1.4.1.476.1.1.1.10.1.1
The firmware revision level of the UPS.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(255)  

ls43cUpsConfig 1.3.6.1.4.1.476.1.1.1.10.12
OBJECT IDENTIFIER    

ls43cUpsConfigBypassInstalled 1.3.6.1.4.1.476.1.1.1.10.12.1
Indicates if a bypass is installed in the UPS.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), yes(2), no(3)  

ls43cUpsBypass 1.3.6.1.4.1.476.1.1.1.10.13
OBJECT IDENTIFIER    

ls43cUpsOnBypass 1.3.6.1.4.1.476.1.1.1.10.13.1
Indicates that the UPS is currently on bypass.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), yes(2), no(3)  

ls43cUpsBypassFrequency 1.3.6.1.4.1.476.1.1.1.10.13.2
The current bypass frequency. (Unit of measure: Hertz)
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..65536  

ls43cUpsBypassNumLines 1.3.6.1.4.1.476.1.1.1.10.13.3
The number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 1..3  

ls43cUpsBypassTable 1.3.6.1.4.1.476.1.1.1.10.13.4
Tok_String
Status: optional Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ls43cUpsBypassEntry

ls43cUpsBypassEntry 1.3.6.1.4.1.476.1.1.1.10.13.4.1
Tok_String
Status: optional Access: not-accessible
OBJECT-TYPE    
  Ls43cUpsBypassEntry  

ls43cUpsBypassLine 1.3.6.1.4.1.476.1.1.1.10.13.4.1.1
The bypass Line.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 1..3  

ls43cUpsBypassVoltage 1.3.6.1.4.1.476.1.1.1.10.13.4.1.2
The bypass voltage. (Unit of measure: Volt)
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..65536  

ls43cUpsBypassCurrent 1.3.6.1.4.1.476.1.1.1.10.13.4.1.3
The bypass current. (Unit of measure: Amp)
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..65536  

luSeries300 1.3.6.1.4.1.476.1.1.1.5
OBJECT IDENTIFIER    

luExternal 1.3.6.1.4.1.476.1.1.1.6
OBJECT IDENTIFIER    

luUPStationS3 1.3.6.1.4.1.476.1.1.1.7
OBJECT IDENTIFIER    

luUpsModule 1.3.6.1.4.1.476.1.1.1.11
OBJECT IDENTIFIER    

luSystemCabinet 1.3.6.1.4.1.476.1.1.1.12
OBJECT IDENTIFIER    

luUPStationGxt 1.3.6.1.4.1.476.1.1.1.14
OBJECT IDENTIFIER    

luPowerSure 1.3.6.1.4.1.476.1.1.1.15
OBJECT IDENTIFIER