LIEBERT-MICRO-UPS-MIB
File:
LIEBERT-MICRO-UPS-MIB.mib (11799 bytes)
Imported modules
Imported symbols
Defined Types
LcUpsAlarmEntry |
|
SEQUENCE |
|
|
|
|
lcUpsAlarmId |
INTEGER |
|
|
lcUpsAlarmDescr |
OBJECT IDENTIFIER |
|
|
lcUpsAlarmTime |
TimeTicks |
|
Defined Values
emerson |
1.3.6.1.4.1.476 |
OBJECT IDENTIFIER |
|
|
|
luPrivate |
1.3.6.1.4.1.476.1.1.3 |
OBJECT IDENTIFIER |
|
|
|
luCore |
1.3.6.1.4.1.476.1.1.1.1 |
OBJECT IDENTIFIER |
|
|
|
lcUpsIdent |
1.3.6.1.4.1.476.1.1.1.1.1 |
OBJECT IDENTIFIER |
|
|
|
lcUpsIdentModel |
1.3.6.1.4.1.476.1.1.1.1.1.2 |
The UPS Model designation. |
Status: optional |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(255) |
|
lcUpsIdentSpecific |
1.3.6.1.4.1.476.1.1.1.1.1.4 |
A reference to MIB definitions specific to the
particular UPS being managed. This object is
used to locate the product-specific MIB for this
device.
If this information is not present, its value
should be the OBJECT IDENTIFIER { 0 0 },
which is a syntactically valid object identifier,
and any conformant implementation of ASN.1 and BER
must be able to generate and recognize this
value. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OBJECT IDENTIFIER |
|
|
lcUpsAlarm |
1.3.6.1.4.1.476.1.1.1.1.6 |
OBJECT IDENTIFIER |
|
|
|
lcUpsAlarms |
1.3.6.1.4.1.476.1.1.1.1.6.1 |
The current number of alarm conditions. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Gauge |
|
|
lcUpsAlarmEntry |
1.3.6.1.4.1.476.1.1.1.1.6.2.1 |
Tok_String |
Status: optional |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
LcUpsAlarmEntry |
|
|
lcUpsAlarmId |
1.3.6.1.4.1.476.1.1.1.1.6.2.1.1 |
A unique identifier for an alarm condition. This
value must remain constant between agent
initializations. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..2147483647 |
|
lcUpsAlarmDescr |
1.3.6.1.4.1.476.1.1.1.1.6.2.1.2 |
A reference to an alarm description object. The
object referenced should not be accessible, but
rather be used to provide a unique description of
the alarm condition. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OBJECT IDENTIFIER |
|
|
lcUpsAlarmTime |
1.3.6.1.4.1.476.1.1.1.1.6.2.1.3 |
The value of sysUpTime when the alarm condition
occured. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
TimeTicks |
|
|
lcUpsControlUnixShutdownDelay |
1.3.6.1.4.1.476.1.1.1.1.8.5 |
Setting this object causes the agent to instruct
the UPS to perform a UNIX Shutdown in the indicated
number of seconds. The agent counts down the number
of seconds until the event will take place. A Unix
shutdown is only valid if the UPS is on Battery.
During a UNIX Shutdown, the UPS will turn off the
output even if the Utility comes back on line before
the shutdown time arrives. Note that different models
have different clock resolutions, usually greater
than 1 second. As a result, the command will only
be accurate to the resolution of the UPS's clock.
The command can be cancelled by setting
lcUpsControlCancelCommand to the value 'cancel'. |
Status: optional |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..2147483647 |
|
lcUpsControlUnixShutdownTrapDelay |
1.3.6.1.4.1.476.1.1.1.1.8.6 |
When 'lcUpsControlUnixShutdownDelay' reaches a value
less than or equal to this object's value, an
lcUpsUnixShutdownWarningTrap will be produced and
this object will be reset to 0. |
Status: optional |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..2147483647 |
|
lcUpsControlCancelCommands |
1.3.6.1.4.1.476.1.1.1.1.8.7 |
Setting this variable to 'cancel' will cause the
agent to issue instructions to the UPS to cancel all
outstanding commands, such as lcUpsControlOutputOff,
lcUpsControlOutputOn, lcUpsControlUnixShutdown. |
Status: optional |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
unknown(1), cancel(2) |
|
lcUpsControlRebootAgentDelay |
1.3.6.1.4.1.476.1.1.1.1.8.8 |
Setting this object causes the agent to reboot after
the indicated number of seconds have expired. The
value will count down until the event takes place.
The command can be cancelled by setting
lcUpsControlCancleCommand to the value cancel. |
Status: optional |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..2147483647 |
|
lcUpsNominalOutputVoltage |
1.3.6.1.4.1.476.1.1.1.1.9.1 |
The nominal output voltage. (Unit of measure:
volt) |
Status: optional |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65536 |
|
lcUpsNominalOutputVA |
1.3.6.1.4.1.476.1.1.1.1.9.3 |
The nominal Volt-Amp rating. |
Status: optional |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65536 |
|
lcUpsNominalOutputWatts |
1.3.6.1.4.1.476.1.1.1.1.9.4 |
The nominal power rating. (Unit of measure:
watt) |
Status: optional |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65536 |
|
lcUpsNominalOutputFreq |
1.3.6.1.4.1.476.1.1.1.1.9.5 |
The nominal output frequency. (Unit of measure:
Hertz) |
Status: optional |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65536 |
|
lcUpsTraps |
1.3.6.1.4.1.476.1.1.1.1.11 |
OBJECT IDENTIFIER |
|
|
|
lcUpsOnBatteryTrap |
3 |
An lcUpsOnBatteryTrap signifies that the
UPS is currently on Battery Power. |
TRAP-TYPE |
|
|
|
lcUpsAlarmTrap |
11 |
An Alarm condition has occurred and is being reported
in the lcUpsAlarmTable. |
TRAP-TYPE |
|
|
|
lcUpsUnixShutdownTrap |
16 |
An lcUpsUnixShutodwnTrap is sent 2 seconds before
the UPS is scheduled to perform a Unix Shutdown. |
TRAP-TYPE |
|
|
|
lcUpsUnixShutdownWarningTrap |
17 |
An lcUpsUnixShutdownWarningTrap is sent when the
lcUpsControlUnixShudownDelay reaches the value of
lcUpsControlUnixShutdownTrapDelay. |
TRAP-TYPE |
|
|
|
luExternal |
1.3.6.1.4.1.476.1.1.1.6 |
OBJECT IDENTIFIER |
|
|
|