LgpPduEntry |
|
SEQUENCE |
|
|
|
|
lgpPduEntryIndex |
Unsigned32 |
|
|
lgpPduEntryId |
Unsigned32 |
|
|
lgpPduEntryUsrLabel |
DisplayString |
|
|
lgpPduEntrySysAssignLabel |
DisplayString |
|
|
lgpPduEntryPositionRelative |
Unsigned32 |
|
|
lgpPduEntrySysStatus |
Unsigned32 |
|
|
lgpPduEntryUsrTag1 |
DisplayString |
|
|
lgpPduEntryUsrTag2 |
DisplayString |
|
|
lgpPduEntrySerialNumber |
DisplayString |
|
|
lgpPduEntryRbCount |
Unsigned32 |
|
|
lgpPduEntrySWOverCurrentProtection |
INTEGER |
|
LgpPduPsEntry |
|
SEQUENCE |
|
|
|
|
lgpPduPsEntryIndex |
Unsigned32 |
|
|
lgpPduPsEntryId |
Unsigned32 |
|
|
lgpPduPsEntrySysAssignLabel |
DisplayString |
|
|
lgpPduPsEntryModel |
DisplayString |
|
|
lgpPduPsEntryWiringType |
INTEGER |
|
|
lgpPduPsEntryEpInputRated |
Unsigned32 |
|
|
lgpPduPsEntryEcInputRated |
Unsigned32 |
|
|
lgpPduPsEntryFreqRated |
Unsigned32 |
|
|
lgpPduPsEntryEnergyAccum |
Unsigned32 |
|
|
lgpPduPsEntrySerialNum |
DisplayString |
|
|
lgpPduPsEntryFirmwareVersion |
DisplayString |
|
|
lgpPduPsEntryPwrTotal |
Unsigned32 |
|
|
lgpPduPsEntryEcNeutral |
Unsigned32 |
|
|
lgpPduPsEntryEcNeutralThrshldOvrWarn |
Unsigned32 |
|
|
lgpPduPsEntryEcNeutralThrshldOvrAlarm |
Unsigned32 |
|
|
lgpPduPsEntryUnbalancedLoadThrshldAlarm |
Unsigned32 |
|
|
lgpPduPsEntryApTotal |
Unsigned32 |
|
|
lgpPduPsEntryPfTotal |
Integer32 |
|
LgpPduPsLineEntry |
|
SEQUENCE |
|
|
|
|
lgpPduPsLineEntryIndex |
Unsigned32 |
|
|
lgpPduPsLineEntryId |
Unsigned32 |
|
|
lgpPduPsLineEntryLine |
INTEGER |
|
|
lgpPduPsLineEntryEpLNTenths |
Unsigned32 |
|
|
lgpPduPsLineEntryEpLN |
Unsigned32 |
|
|
lgpPduPsLineEntryEc |
Unsigned32 |
|
|
lgpPduPsLineEntryEcHundredths |
Unsigned32 |
|
|
lgpPduPsLineEntryEcThrshldUndrAlarm |
Unsigned32 |
|
|
lgpPduPsLineEntryEcThrshldOvrWarn |
Unsigned32 |
|
|
lgpPduPsLineEntryEcThrshldOvrAlarm |
Unsigned32 |
|
|
lgpPduPsLineEntryEcAvailBeforeAlarm |
Unsigned32 |
|
|
lgpPduPsLineEntryEcUsedBeforeAlarm |
Unsigned32 |
|
|
lgpPduPsLineEntryEpLL |
Unsigned32 |
|
|
lgpPduPsLineEntryEpLLTenths |
Unsigned32 |
|
|
lgpPduPsLineEntryEcAvailBeforeAlarmHundredths |
Unsigned32 |
|
|
lgpPduPsLineEntryPwrLN |
Unsigned32 |
|
|
lgpPduPsLineEntryPwrLL |
Unsigned32 |
|
|
lgpPduPsLineEntryApLN |
Unsigned32 |
|
|
lgpPduPsLineEntryApLL |
Unsigned32 |
|
|
lgpPduPsLineEntryPfLN |
Integer32 |
|
|
lgpPduPsLineEntryPfLL |
Integer32 |
|
LgpPduRbEntry |
|
SEQUENCE |
|
|
|
|
lgpPduRbEntryIndex |
Unsigned32 |
|
|
lgpPduRbEntryId |
Unsigned32 |
|
|
lgpPduRbEntryUsrLabel |
DisplayString |
|
|
lgpPduRbEntrySysAssignLabel |
DisplayString |
|
|
lgpPduRbEntryPositionRelative |
Unsigned32 |
|
|
lgpPduRbEntrySerialNum |
DisplayString |
|
|
lgpPduRbEntryModel |
DisplayString |
|
|
lgpPduRbEntryFirmwareVersion |
DisplayString |
|
|
lgpPduRbEntryUsrTag1 |
DisplayString |
|
|
lgpPduRbEntryUsrTag2 |
DisplayString |
|
|
lgpPduRbEntryReceptacleType |
INTEGER |
|
|
lgpPduRbEntryCapabilities |
INTEGER |
|
|
lgpPduRbEntryLineSource |
INTEGER |
|
|
lgpPduRbEntryRcpCount |
Unsigned32 |
|
|
lgpPduRbEntryEpRated |
Unsigned32 |
|
|
lgpPduRbEntryEcRated |
Unsigned32 |
|
|
lgpPduRbEntryFreqRated |
Unsigned32 |
|
|
lgpPduRbEntryEnergyAccum |
Unsigned32 |
|
|
lgpPduRbEntryEpLNTenths |
Unsigned32 |
|
|
lgpPduRbEntryPwr |
Unsigned32 |
|
|
lgpPduRbEntryAp |
Unsigned32 |
|
|
lgpPduRbEntryPf |
Integer32 |
|
|
lgpPduRbEntryEcHundredths |
Unsigned32 |
|
|
lgpPduRbEntryEcThrshldUndrAlm |
Unsigned32 |
|
|
lgpPduRbEntryEcThrshldOvrWarn |
Unsigned32 |
|
|
lgpPduRbEntryEcThrshldOvrAlm |
Unsigned32 |
|
|
lgpPduRbEntryEcAvailBeforeAlarmHundredths |
Unsigned32 |
|
|
lgpPduRbEntryEcUsedBeforeAlarm |
Unsigned32 |
|
|
lgpPduRbEntryEpLLTenths |
Unsigned32 |
|
|
lgpPduRbEntrySwOverCurrentProtection |
INTEGER |
|
LgpPduRbLineEntry |
|
SEQUENCE |
|
|
|
|
lgpPduRbLineEntryIndex |
Unsigned32 |
|
|
lgpPduRbLineEntryId |
Unsigned32 |
|
|
lgpPduRbLineEntryLine |
INTEGER |
|
|
lgpPduRbLineEntryEpLNTenths |
Unsigned32 |
|
|
lgpPduRbLineEntryEpLN |
Unsigned32 |
|
|
lgpPduRbLineEntryEc |
Unsigned32 |
|
|
lgpPduRbLineEntryPwr |
Unsigned32 |
|
|
lgpPduRbLineEntryAp |
Unsigned32 |
|
|
lgpPduRbLineEntryPf |
Integer32 |
|
|
lgpPduRbLineEntryEcHundredths |
Unsigned32 |
|
|
lgpPduRbLineEntryEcThrshldUndrAlm |
Unsigned32 |
|
|
lgpPduRbLineEntryEcThrshldOvrWarn |
Unsigned32 |
|
|
lgpPduRbLineEntryEcThrshldOvrAlm |
Unsigned32 |
|
|
lgpPduRbLineEntryEcAvailBeforeAlarmHundredths |
Unsigned32 |
|
|
lgpPduRbLineEntryEcAvailBeforeAlarm |
Unsigned32 |
|
|
lgpPduRbLineEntryEcUsedBeforeAlarm |
Unsigned32 |
|
|
lgpPduRbLineEntryEpLL |
Unsigned32 |
|
|
lgpPduRbLineEntryEpLLTenths |
Unsigned32 |
|
LgpPduRcpEntry |
|
SEQUENCE |
|
|
|
|
lgpPduRcpEntryIndex |
Unsigned32 |
|
|
lgpPduRcpEntryId |
Unsigned32 |
|
|
lgpPduRcpEntryUsrLabel |
DisplayString |
|
|
lgpPduRcpEntryUsrTag1 |
DisplayString |
|
|
lgpPduRcpEntryUsrTag2 |
DisplayString |
|
|
lgpPduRcpEntrySysAssignLabel |
DisplayString |
|
|
lgpPduRcpEntryPosition |
Unsigned32 |
|
|
lgpPduRcpEntryType |
INTEGER |
|
|
lgpPduRcpEntryLineSource |
INTEGER |
|
|
lgpPduRcpEntryCapabilities |
INTEGER |
|
|
lgpPduRcpEntryEp |
Unsigned32 |
|
|
lgpPduRcpEntryEpTenths |
Unsigned32 |
|
|
lgpPduRcpEntryEc |
Unsigned32 |
|
|
lgpPduRcpEntryEcHundredths |
Unsigned32 |
|
|
lgpPduRcpEntryPwrOut |
Unsigned32 |
|
|
lgpPduRcpEntryApOut |
Unsigned32 |
|
|
lgpPduRcpEntryPf |
Unsigned32 |
|
|
lgpPduRcpEntryFreq |
Unsigned32 |
|
|
lgpPduRcpEntryEnergyAccum |
Unsigned32 |
|
|
lgpPduRcpEntryPwrOnDelay |
Unsigned32 |
|
|
lgpPduRcpEntryPwrState |
INTEGER |
|
|
lgpPduRcpEntryPwrUpState |
INTEGER |
|
|
lgpPduRcpEntryControl |
INTEGER |
|
|
lgpPduRcpEntryControlLock |
INTEGER |
|
|
lgpPduRcpEntryEcThrshldUnderAlarm |
Unsigned32 |
|
|
lgpPduRcpEntryEcThrshldOverWarn |
Unsigned32 |
|
|
lgpPduRcpEntryEcThrshldOverAlarm |
Unsigned32 |
|
|
lgpPduRcpEntryEcAvailBeforeAlarmHundredths |
Unsigned32 |
|
|
lgpPduRcpEntryEcAvailBeforeAlarm |
Unsigned32 |
|
|
lgpPduRcpEntryEcUsedBeforeAlarm |
Unsigned32 |
|
|
lgpPduRcpEntryEcCrestFactor |
Unsigned32 |
|
|
lgpPduRcpEntryBlinkLED |
INTEGER |
|
|
lgpPduRcpEntrySwOverTemperatureProtection |
INTEGER |
|
|
lgpPduRcpEntryOperationCondition |
INTEGER |
|
|
lgpPduRcpEntryCriticality |
INTEGER |
|
|
lgpPduRcpEntryPostOnDelay |
Unsigned32 |
|
|
lgpPduRcpEntryPostOffDelay |
Unsigned32 |
|
|
lgpPduRcpEntryAddReceptacleToGroup |
OBJECT IDENTIFIER |
|
|
lgpPduRcpEntryRemoveReceptacleFromGroup |
OBJECT IDENTIFIER |
|
LgpPduRcpGroupEntry |
|
SEQUENCE |
|
|
|
|
lgpPduRcpGroupIndex |
Unsigned32 |
|
|
lgpPduRcpGroupUsrLabel |
DisplayString |
|
|
lgpPduRcpGroupDeleteGroup |
INTEGER |
|
|
lgpPduRcpGroupControlPower |
INTEGER |
|
|
lgpPduRcpGroupControlLock |
INTEGER |
|
|
lgpPduRcpGroupBlinkLED |
INTEGER |
|
LgpPduRcpGroupDisplayEntry |
|
SEQUENCE |
|
|
|
|
lgpPduRcpGroupDisplayIndex |
Unsigned32 |
|
|
lgpPduRcpGroupDisplayGroup |
DisplayString |
|
LgpPduAuxSensorEntry |
|
SEQUENCE |
|
|
|
|
lgpPduAuxSensorIndex |
Unsigned32 |
|
|
lgpPduAuxSensorMeasType |
INTEGER |
|
|
lgpPduAuxSensorId |
Unsigned32 |
|
|
lgpPduAuxSensorSysAssignLabel |
DisplayString |
|
|
lgpPduAuxSensorPositionRelative |
Unsigned32 |
|
|
lgpPduAuxSensorUsrLabel |
DisplayString |
|
|
lgpPduAuxSensorUsrTag1 |
DisplayString |
|
|
lgpPduAuxSensorUsrTag2 |
DisplayString |
|
|
lgpPduAuxSensorTempSerialNum |
DisplayString |
|
|
lgpPduAuxSensorHumSerialNum |
DisplayString |
|
|
lgpPduAuxSensorTempMeasurementDegF |
Integer32 |
|
|
lgpPduAuxSensorTempThrshldUndrAlmDegF |
Integer32 |
|
|
lgpPduAuxSensorTempThrshldOvrAlmDegF |
Integer32 |
|
|
lgpPduAuxSensorTempThrshldUndrWarnDegF |
Integer32 |
|
|
lgpPduAuxSensorTempThrshldOvrWarnDegF |
Integer32 |
|
|
lgpPduAuxSensorTempMeasurementDegC |
Integer32 |
|
|
lgpPduAuxSensorTempThrshldUndrAlmDegC |
Integer32 |
|
|
lgpPduAuxSensorTempThrshldOvrAlmDegC |
Integer32 |
|
|
lgpPduAuxSensorTempThrshldUndrWarnDegC |
Integer32 |
|
|
lgpPduAuxSensorTempThrshldOvrWarnDegC |
Integer32 |
|
|
lgpPduAuxSensorHumMeasurement |
Unsigned32 |
|
|
lgpPduAuxSensorHumThrshldUndrAlm |
Unsigned32 |
|
|
lgpPduAuxSensorHumThrshldOvrAlm |
Unsigned32 |
|
|
lgpPduAuxSensorHumThrshldUndrWarn |
Unsigned32 |
|
|
lgpPduAuxSensorHumThrshldOvrWarn |
Unsigned32 |
|
LgpPduAuxMeasEntry |
|
SEQUENCE |
|
|
|
|
lgpPduAuxMeasSensorIndex |
Unsigned32 |
|
|
lgpPduAuxMeasSensorMeasurementIndex |
Unsigned32 |
|
|
lgpPduAuxMeasType |
INTEGER |
|
|
lgpPduAuxMeasSensorSysAssignLabel |
DisplayString |
|
|
lgpPduAuxMeasUsrLabel |
DisplayString |
|
|
lgpPduAuxMeasUsrTag1 |
DisplayString |
|
|
lgpPduAuxMeasUsrTag2 |
DisplayString |
|
|
lgpPduAuxMeasSensorSerialNum |
DisplayString |
|
|
lgpPduAuxMeasTempDegF |
Integer32 |
|
|
lgpPduAuxMeasTempThrshldUndrAlmDegF |
Integer32 |
|
|
lgpPduAuxMeasTempThrshldOvrAlmDegF |
Integer32 |
|
|
lgpPduAuxMeasTempThrshldUndrWarnDegF |
Integer32 |
|
|
lgpPduAuxMeasTempThrshldOvrWarnDegF |
Integer32 |
|
|
lgpPduAuxMeasTempDegC |
Integer32 |
|
|
lgpPduAuxMeasTempThrshldUndrAlmDegC |
Integer32 |
|
|
lgpPduAuxMeasTempThrshldOvrAlmDegC |
Integer32 |
|
|
lgpPduAuxMeasTempThrshldUndrWarnDegC |
Integer32 |
|
|
lgpPduAuxMeasTempThrshldOvrWarnDegC |
Integer32 |
|
|
lgpPduAuxMeasHum |
Unsigned32 |
|
|
lgpPduAuxMeasHumThrshldUndrAlm |
Unsigned32 |
|
|
lgpPduAuxMeasHumThrshldOvrAlm |
Unsigned32 |
|
|
lgpPduAuxMeasHumThrshldUndrWarn |
Unsigned32 |
|
|
lgpPduAuxMeasHumThrshldOvrWarn |
Unsigned32 |
|
|
lgpPduAuxMeasDrClosureState |
INTEGER |
|
|
lgpPduAuxMeasDrClosureConfig |
INTEGER |
|
|
lgpPduAuxMeasCntctClosureState |
INTEGER |
|
|
lgpPduAuxMeasCntctClosureConfig |
INTEGER |
|
|
lgpPduAuxMeasDiffPressure |
Integer32 |
|
|
lgpPduAuxMeasDiffPressureThrshldUndrAlm |
Integer32 |
|
|
lgpPduAuxMeasDiffPressureThrshldOvrAlm |
Integer32 |
|
|
lgpPduAuxMeasDiffPressureThrshldUndrWarn |
Integer32 |
|
|
lgpPduAuxMeasDiffPressureThrshldOvrWarn |
Integer32 |
|
|
lgpPduAuxMeasLeakDetectState |
INTEGER |
|
LgpPduAuxMeasOrderEntry |
|
SEQUENCE |
|
|
|
|
lgpPduEntryIndex |
Unsigned32 |
|
|
lgpPduAuxSensorOrderIndex |
Unsigned32 |
|
|
lgpPduAuxMeasOrderSensorSerialNum |
DisplayString |
|
lgpPduEntrySWOverTemperatureProtectionConfig |
1.3.6.1.4.1.476.1.42.3.8.5.5 |
This configures the scope of behavior for the PDU Software Over
Temperature Protection feature.
See lgpPduRcpEntrySwOverTemperatureProtection to enable this feature
and get further information about what actions will be performed.
local (0)
Only receptacles on the PDU with the alarming temperature sensor
will be affected.
array (1)
All receptacles in the PDU array will be affected, regardless of
which PDU the alarming temperature sensor is connected to.
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
local(0), array(1) |
|
lgpPduEntrySWOverTemperatureProtectionDelay |
1.3.6.1.4.1.476.1.42.3.8.5.10 |
This sets the delay for the PDU Software Over Temperature Protection
feature. This value determines the amount of time to delay, after the
high temperature alarm becomes active, before taking action on the
enabled receptacles. If the high temperature alarm becomes inactive
before the expiration of the delay time, no action will be taken on
the enabled receptacles.
See lgpPduRcpEntrySwOverTemperatureProtection to enable this feature
and get further information about what actions will be performed.
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduEntry |
1.3.6.1.4.1.476.1.42.3.8.20.1 |
This entry defines the columns to be populated in the
'lgpPduTable'. Each column represents an attribute of a PDU.
This table is indexed by the PDU identifier that is unique
within the agent.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
LgpPduEntry |
|
|
lgpPduEntryIndex |
1.3.6.1.4.1.476.1.42.3.8.20.1.1 |
This is the index that indicates the row of the 'lgpPduTable'. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduEntryId |
1.3.6.1.4.1.476.1.42.3.8.20.1.5 |
This is an internal index representing a unique identifier for
each PDU represented by this agent. The value is assigned
by the agent. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduEntryUsrLabel |
1.3.6.1.4.1.476.1.42.3.8.20.1.10 |
This is a user assigned label representing the PDU. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
lgpPduEntrySysAssignLabel |
1.3.6.1.4.1.476.1.42.3.8.20.1.15 |
System assigned identifier representing the PDU. The value
is independent of any user assigned label or tag. The exact format
of this label is system dependent and is subject to change,
therefore, it should not be referenced for programmatic use. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
lgpPduEntryPositionRelative |
1.3.6.1.4.1.476.1.42.3.8.20.1.20 |
This is a one-based value that indicates the PDU's relative
position within a rack or other enclosing entity. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduEntrySysStatus |
1.3.6.1.4.1.476.1.42.3.8.20.1.25 |
This value represents a bit-field of the various operational
states of the PDU. The value is a logical OR of all of the
following potential states of the PDU. Note the bit-position
is given parenthetically next to the operational state in the
description below. The bit position is assumed to be a big-endian
format (least significant digit is the right-most digit). The
state is present in the PDU when the bit is on (value = 1).
normalOperation(1)
The PDU is operating normally with no active warnings or alarms.
startUp(2)
The PDU is in the startup state (initializing). Control
and monitoring operations maybe inhibited or unavailable
while the PDU is in this state. This state will clear
automatically when the PDU(s) are fully initialized and
ready to accept control and monitoring commands.
normalWithWarning(8)
The PDU is operating normally with one or more active
warnings. Appropriate personnel should investigate the
warning(s) as soon as possible and take appropriate action.
normalWithAlarm(16)
The PDU is operating normally with one or more active
alarms. Appropriate personnel should investigate the alarm(s)
as soon as possible and take appropriate action.
abnormalOperation(32)
The PDU is operating abnormally. That is there is some
failure within the system that is unexpected under normal
operating conditions. Appropriate personnel should investigate
the cause as soon as possible. The normal functioning of
the system is likely inhibited.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduEntryUsrTag1 |
1.3.6.1.4.1.476.1.42.3.8.20.1.35 |
This is a user assigned Tag for the PDU. This value may be
useful for end-user grouping or asset tracking purposes.
The value for this tag does not need to be unique for this
unit or across other units. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
lgpPduEntryUsrTag2 |
1.3.6.1.4.1.476.1.42.3.8.20.1.40 |
This is a user assigned Tag for the PDU. This value may be
useful for end-user grouping or asset tracking purposes.
The value for this tag does not need to be unique for this
unit or across other units. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
lgpPduEntrySerialNumber |
1.3.6.1.4.1.476.1.42.3.8.20.1.45 |
System assigned serial number for this PDU. This number is
assigned at time of manufacture, is globally unique with respect
to all PDU units. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
lgpPduEntryRbCount |
1.3.6.1.4.1.476.1.42.3.8.20.1.50 |
Number of receptacle branches (Rb) within this PDU. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduEntrySWOverCurrentProtection |
1.3.6.1.4.1.476.1.42.3.8.20.1.55 |
This is the PDU Software Over Current Protection feature which will
prevent unused receptacles from turning on when the
'PDU Over Current Warning' or 'PDU Over Current Alarm' threshold
is violated. Such receptacles shall get locked to prevent any user
from switching them ON. Only device-admin shall have the authorization
to unlock such receptacles.
If the feature is enabled, in case of PDU Over Current Warning or Alarm condition,
following action will be taken on the receptacles:
a. Locked & OFF - No change
b. Locked & ON - No change
c. UnLocked & OFF - Receptacle shall be locked
d. Unlocked & ON - If the receptacle is being used (current>0), no change.
If that outlet is being unused(current=0), turn it off and lock it in that position.
No action will be taken if the feature is disabled.
Note: Only applicable to PDU models where receptacle measurement and control is supported.
Not applicable for PDU models that support only branch monitoring.
disabled
This function is disabled.
enable
This function is enabled. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
disabled(0), enable(1) |
|
lgpPduPsEntry |
1.3.6.1.4.1.476.1.42.3.8.30.20.1 |
This entry defines the attributes to be populated in the
various columns of the 'lgpPduPsTable' (Power Source Table).
This table is indexed by both the 'lgpPduEntryIndex' which is
the sole index into the 'lgpPduTable' and the 'lgpPduPsEntryIndex'
which is a unique identifier for the Power Source within a
given PDU. Taken together these two indexes uniquely identify
a Power Source within this agent.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
LgpPduPsEntry |
|
|
lgpPduPsEntryIndex |
1.3.6.1.4.1.476.1.42.3.8.30.20.1.5 |
This is a unique identifier for the Power Source within a
given PDU. This is one of two indexes used to indicate the row of
the 'lgpPduTable'. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduPsEntryId |
1.3.6.1.4.1.476.1.42.3.8.30.20.1.10 |
This is a unique entry id representing a given PDU power source
for the PDU. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduPsEntrySysAssignLabel |
1.3.6.1.4.1.476.1.42.3.8.30.20.1.15 |
System assigned identifier for this power source. The value
is independent of any user assigned label or tag. The exact format
of this label is system dependent and is subject to change,
therefore, it should not be referenced for programmatic use. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
lgpPduPsEntryModel |
1.3.6.1.4.1.476.1.42.3.8.30.20.1.20 |
This is the model name (identifier) of the power supply. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
lgpPduPsEntryWiringType |
1.3.6.1.4.1.476.1.42.3.8.30.20.1.25 |
The PDU's power supply physical wiring type.
not-specified
The type has not been specified/configured. The end_user
must configure this object to specify the physical wiring
type.
single-phase-3-wire-L1-N-PE
Single Phase input with 3 wires (Line 1, Neutral and
Protective Earth).
two-phase-3-wire-L1-L2-PE
Two Phase input with 3 wires (Line 1, Line 2, and
Protective Earth).
three-phase-4-wire-L1-L2-L3-PE
Three Phase input with 4 wires (Line 1, Line 2, Line 3,
and Protective Earth).
three-phase-5-wire-L1-L2-L3-N-PE
Three Phase input with 5 wires (Line 1, Line 2, Line 3,
Neutral and Protective Earth).
two-phase-4-wire-L1-L2-N-PE
Two Phase input with 4 wires (Line 1, Line 2, Neutral,
and Protective Earth). |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
not-specified(0), single-phase-3-wire-L1-N-PE(1), two-phase-3-wire-L1-L2-PE(2), three-phase-4-wire-L1-L2-L3-PE(3), three-phase-5-wire-L1-L2-L3-N-PE(4), two-phase-4-wire-L1-L2-N-PE(5) |
|
lgpPduPsEntryFreqRated |
1.3.6.1.4.1.476.1.42.3.8.30.20.1.40 |
Rated input line frequency for this power source
(i.e. This is the expected line frequency; it is NOT a
measured frequency; it is typically 50 Hz or 60 Hz). |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduPsEntryEnergyAccum |
1.3.6.1.4.1.476.1.42.3.8.30.20.1.50 |
Total accumulated energy, measured at the power source input, since
the last energy reset. Writing a value of 0 (zero) to this
causes the accumulated energy to be reset. Writing a non-zero
value is invalid and shall result in a write error and the
total energy value remains unchanged.
If the energy has not been reset and has not wrapped,
then this is the total energy since installation.
This value persists across boot events. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduPsEntrySerialNum |
1.3.6.1.4.1.476.1.42.3.8.30.20.1.55 |
This is a unique serial number of the power supply. This number
is assigned to the power supply at the time of manufacture. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
lgpPduPsEntryFirmwareVersion |
1.3.6.1.4.1.476.1.42.3.8.30.20.1.60 |
This is the version of the firmware installed on the PDU's
power supply. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
lgpPduPsEntryPwrTotal |
1.3.6.1.4.1.476.1.42.3.8.30.20.1.65 |
Total input power for this power supply. This is the sum of the
power for all phases |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduPsEntryEcNeutral |
1.3.6.1.4.1.476.1.42.3.8.30.20.1.70 |
The neutral current measured at the PDU's power source. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduPsEntryEcNeutralThrshldOvrWarn |
1.3.6.1.4.1.476.1.42.3.8.30.20.1.75 |
The threshold at which an over current warning is activated. If the
measured neutral current (lgpPduPsEntryEcNeutral) is above this
percentage of the full scale rated value
(lgpPduPsEntryEcInputRated), an over neutral current warning
(lgpConditionSource1NeutralOverCurrent) is activated. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduPsEntryEcNeutralThrshldOvrAlarm |
1.3.6.1.4.1.476.1.42.3.8.30.20.1.80 |
The threshold at which an over current alarm is activated. If the
measured neutral current (lgpPduPsEntryEcNeutral) is above this
percentage of the full scale rated value
(lgpPduPsEntryEcInputRated), an over neutral current alarm
(lgpConditionSource1NeutralOverCurrent) is activated. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduPsEntryUnbalancedLoadThrshldAlarm |
1.3.6.1.4.1.476.1.42.3.8.30.20.1.85 |
The parameter is for setting the maximum acceptable percentage of
'Unbalanced Load' between any two phases. This setting shall
trigger an alarm when the % load between any two phases varies by
a percentage higher than this configurable value. If this value is
0% then the alarm would be deactivated. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduPsEntryApTotal |
1.3.6.1.4.1.476.1.42.3.8.30.20.1.90 |
Total Apparent power for this power supply. This is the sum of the
apparent power for all phases |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduPsEntryPfTotal |
1.3.6.1.4.1.476.1.42.3.8.30.20.1.95 |
Total power factor, which is real power/apparent power for all
phases combined. This is the sum of the real power for all phases
divided by the sum of the apparent power for all phases. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
lgpPduPsLineEntry |
1.3.6.1.4.1.476.1.42.3.8.30.40.1 |
This entry defines the attributes to be populated in the
various columns of the 'lgpPduPsLineTable'.
The table is index by three indexes which taken together
uniquely identify line/phase information for a given power source
within a PDU. The 'lgpPduEntryIndex' is an index into the
'lgpPduTable'. This identifies the PDU that the power source
is on. The 'lgpPduPsEntryIndex' is an index that together with
the 'lgpPduEntryIndex' uniquely identifies the power source
within the PDU that the row in this table represents. The final
index 'lgpPduPsLineEntryIndex' identifies the particular
line/phase that the measurement applies to within the identified
power source. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
LgpPduPsLineEntry |
|
|
lgpPduPsLineEntryIndex |
1.3.6.1.4.1.476.1.42.3.8.30.40.1.5 |
This is the index that indicates the line/phase of the measurements
in the given row of the 'lgpPduPsLineTable'. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduPsLineEntryId |
1.3.6.1.4.1.476.1.42.3.8.30.40.1.10 |
Unique identifier (within a PDU) for the PDU's power source.
The object may not be available in non-modular systems. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduPsLineEntryLine |
1.3.6.1.4.1.476.1.42.3.8.30.40.1.15 |
The line number (phase) that the measurement represents for all
measurements in a given row of the table. Note that this always
matches the lgpPduPsLineEntryIndex of the same row in the table.
The line/phases are as follows:
Line# Description
----- ---------------------------------------------------
1 Line 1-N (A) for Line-to-Neutral measurements
2 Line 2-N (B) for Line-to-Neutral measurements
3 Line 3-N (C) for Line-to-Neutral measurements
1 Line 1-2 (A-B) for Line-to-Line measurements
2 Line 2-3 (B-C) for Line-to-Line measurements
3 Line 3-1 (C-A) for Line-to-Line measurements
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
phase1(1), phase2(2), phase3(3) |
|
lgpPduPsLineEntryEpLNTenths |
1.3.6.1.4.1.476.1.42.3.8.30.40.1.19 |
Alternating Current RMS Line to Neutral Electrical Potential
measurement.
The line/phase being measured is indicated by the corresponding
lgpPduPsLineEntryLine value of this row in the table. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduPsLineEntryEpLN |
1.3.6.1.4.1.476.1.42.3.8.30.40.1.20 |
Alternating Current RMS Line to Neutral Electrical Potential
measurement.
The line/phase being measured is indicated by the corresponding
lgpPduPsLineEntryLine value of this row in the table. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduPsLineEntryEc |
1.3.6.1.4.1.476.1.42.3.8.30.40.1.21 |
Total input line-to-neutral electrical current.
The line/phase being measured is indicated by the corresponding
lgpPduPsLineEntryLine value of this row in the table. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduPsLineEntryEcHundredths |
1.3.6.1.4.1.476.1.42.3.8.30.40.1.22 |
Total input line-to-neutral electrical current.
The line/phase being measured is indicated by the corresponding
lgpPduPsLineEntryLine value of this row in the table. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduPsLineEntryEcThrshldUndrAlarm |
1.3.6.1.4.1.476.1.42.3.8.30.40.1.35 |
The threshold at which an under current alarm is activated. If
the measured current (lgpPduPsLineEntryEc) is equal to or below
this percentage of the full scale rated value
(lgpPduPsEntryEcInputRated), an under current alarm
is activated. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduPsLineEntryEcThrshldOvrWarn |
1.3.6.1.4.1.476.1.42.3.8.30.40.1.36 |
The threshold at which an over current warning is activated. If
the measured current (lgpPduPsLineEntryEc) is equal to or over
this percentage of the full scale rated value
(lgpPduPsEntryEcInputRated), an over current warning
is activated. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduPsLineEntryEcThrshldOvrAlarm |
1.3.6.1.4.1.476.1.42.3.8.30.40.1.37 |
The threshold at which an over current alarm is activated. If
the measured current (lgpPduPsLineEntryEc) is equal to or over
this percentage of the full scale rated value
(lgpPduPsEntryEcInputRated), an over current alarm
is activated. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduPsLineEntryEcAvailBeforeAlarm |
1.3.6.1.4.1.476.1.42.3.8.30.40.1.38 |
The amount that the current/amperage may increase from its present
value before an over current alarm occurs. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduPsLineEntryEcUsedBeforeAlarm |
1.3.6.1.4.1.476.1.42.3.8.30.40.1.39 |
The percent of current utilization relative to the over current
alarm threshold. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduPsLineEntryEpLL |
1.3.6.1.4.1.476.1.42.3.8.30.40.1.60 |
Line to Line Electrical Potential.
The line/phase being measured is indicated by the corresponding
lgpPduPsLineEntryLine value of this row in the table. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduPsLineEntryEpLLTenths |
1.3.6.1.4.1.476.1.42.3.8.30.40.1.61 |
Line to Line Electrical Potential.
The line/phase being measured is indicated by the corresponding
lgpPduPsLineEntryLine value of this row in the table. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduPsLineEntryEcAvailBeforeAlarmHundredths |
1.3.6.1.4.1.476.1.42.3.8.30.40.1.62 |
The amount that the current/amperage may increase from its present
value before an over current alarm occurs. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduPsLineEntryPwrLN |
1.3.6.1.4.1.476.1.42.3.8.30.40.1.63 |
The line-to-neutral measurement of the Real Power (Watts).
The line/phase being measured is indicated by the corresponding
lgpPduPsLineEntryLine value of this row in the table. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduPsLineEntryPwrLL |
1.3.6.1.4.1.476.1.42.3.8.30.40.1.64 |
The line-to-line measurement of the Real Power (Watts).
The line/phase being measured is indicated by the corresponding
lgpPduPsLineEntryLine value of this row in the table. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduPsLineEntryApLN |
1.3.6.1.4.1.476.1.42.3.8.30.40.1.65 |
The line-to-neutral measurement of the Apparent Power (VA).
The line/phase being measured is indicated by the corresponding
lgpPduPsLineEntryLine value of this row in the table. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduPsLineEntryApLL |
1.3.6.1.4.1.476.1.42.3.8.30.40.1.66 |
The line-to-line measurement of the Apparent Power (VA).
The line/phase being measured is indicated by the corresponding
lgpPduPsLineEntryLine value of this row in the table. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduPsLineEntryPfLN |
1.3.6.1.4.1.476.1.42.3.8.30.40.1.67 |
The line-to-neutral measurement of the Power Factor of the
power source.
The line/phase being measured is indicated by the corresponding
lgpPduPsLineEntryLine value of this row in the table. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
lgpPduPsLineEntryPfLL |
1.3.6.1.4.1.476.1.42.3.8.30.40.1.68 |
The line-to-line measurement of the Power Factor of the
power source.
The line/phase being measured is indicated by the corresponding
lgpPduPsLineEntryLine value of this row in the table. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
lgpPduRbEntry |
1.3.6.1.4.1.476.1.42.3.8.40.20.1 |
This entry defines the attributes to be populated in the
various columns of the 'lgpPduRbTable'. The table is indexed
by both the 'lgpPduEntryIndex' and 'lgpPduRbEntryIndex'. The
lgpPduEntryIndex specifies the PDU, defined in the lgpPduTable
that the branch is on. The lgpPduRbEntryIndex uniquely identifies
the branch within that PDU. Taken together the two indexes
uniquely identify a branch being monitored by this agent.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
LgpPduRbEntry |
|
|
lgpPduRbEntryIndex |
1.3.6.1.4.1.476.1.42.3.8.40.20.1.1 |
This is the index that indicates the row of the
'lgpPduRbTable' |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduRbEntryId |
1.3.6.1.4.1.476.1.42.3.8.40.20.1.5 |
A unique id representing the receptacle branch within the
collection of branches being monitored by this agent. The
uniqueness of this id is within the PDUs being managed by
a single agent. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduRbEntryUsrLabel |
1.3.6.1.4.1.476.1.42.3.8.40.20.1.8 |
A user assigned label representing the receptacle branch. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
lgpPduRbEntrySysAssignLabel |
1.3.6.1.4.1.476.1.42.3.8.40.20.1.20 |
System assigned identifier for this receptacle branch. The value
is independent of any user assigned label or tag. The exact format
of this label is system dependent and is subject to change,
therefore, it should not be referenced for programmatic use. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
lgpPduRbEntryPositionRelative |
1.3.6.1.4.1.476.1.42.3.8.40.20.1.25 |
This is a one-based value that indicates the relative
position of the branch within the PDU. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduRbEntrySerialNum |
1.3.6.1.4.1.476.1.42.3.8.40.20.1.30 |
A globally unique serial number for this branch. This number
is assigned to the branch at the time of manufacture and can not
be modified. NOTE: Generally only PDUs with replaceable
receptacle branches will have serial numbers. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
lgpPduRbEntryModel |
1.3.6.1.4.1.476.1.42.3.8.40.20.1.35 |
This is the model designation for this receptacle branch. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
lgpPduRbEntryFirmwareVersion |
1.3.6.1.4.1.476.1.42.3.8.40.20.1.40 |
This is the firmware version number of the control software
running on the receptacle branch. Only PDUs with
replaceable receptacle branches will typically support this
object. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
lgpPduRbEntryUsrTag1 |
1.3.6.1.4.1.476.1.42.3.8.40.20.1.41 |
This is a user assigned Tag for the receptacle branch. This
value may be useful for end-user grouping or asset tracking
purposes. The value for this tag does not need to be unique
for this unit or across other units. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
lgpPduRbEntryUsrTag2 |
1.3.6.1.4.1.476.1.42.3.8.40.20.1.42 |
This is a user assigned Tag for the receptacle branch. This
value may be useful for end-user grouping or asset tracking
purposes. The value for this tag does not need to be unique
for this unit or across other units. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
lgpPduRbEntryReceptacleType |
1.3.6.1.4.1.476.1.42.3.8.40.20.1.45 |
This enumeration represents the type of receptacles installed
on this receptacle branch. All receptacles on this branch are
of this type/style.
not-specified
If this value is returned, either the receptacle type has
not been specified/configured or the agent monitoring this
PDU does not have a SNMP enumeration defined to the type.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
not-specified(0), nema-5-20R-20-Amp(1), iec-C13-sheet-F-10-Amp(2), iec-C19-sheet-J-16-Amp(3), iec-C13-sheet-F-10-Amp-and-iec-C19-sheet-J-16-Amp(4), nema-5-20R-20-Amp-and-iec-C13-sheet-F-10-Amp(5), nema-5-20R-20-Amp-and-iec-C19-sheet-J-16-Amp(6), cee-7-type-E-schuko(7) |
|
lgpPduRbEntryCapabilities |
1.3.6.1.4.1.476.1.42.3.8.40.20.1.50 |
Receptacle branch capabilities describes what an individual branch
is capable of.
no-optional-capabilities
The branch is unable to report measurements and lacks
control capabilities.
measurement-only
The branch is capable of reporting multiple measurements.
measurement-and-control
The branch is capable of reporting multiple measurements
and controlling the state.
control-only
The branch is capable of controlling the state.
current-measurement-only
The branch is capable of reporting the current/amperage only.
current-measurement-and-control
The branch is capable of reporting the current/amperage and
has the ability to control the state. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
not-specified(0), no-optional-capabilities(1), measurement-only(2), measurement-and-control(3), control-only(4), current-measurement-only(5), current-measurement-and-control(6) |
|
lgpPduRbEntryLineSource |
1.3.6.1.4.1.476.1.42.3.8.40.20.1.55 |
This represents the line source that is supplying power to this
receptacle branch.
not-specified
The line source supplying power to the load for this
receptacle branch has not been specified/configured.
line-1-N
The load for this receptacle branch is supplied by
a line-to-neutral configuration. (line 1 to neutral).
line-2-N
The load for this receptacle branch is supplied by
a line-to-neutral configuration. (line 2 to neutral).
line-3-N
The load for this receptacle branch is supplied by
a line-to-neutral configuration. (line 3 to neutral).
line-1-line-2
The load for this receptacle branch is supplied by
a line-to-line configuration (line 1 to line 2).
line-2-line-3
The load for this receptacle branch is supplied by
a line-to-line configuration (line 2 to line 3).
line-3-line-1
The load for this receptacle branch is supplied by
a line-to-line configuration (line 3 to line 1).
line-1-line-2-and-line-1-neutral
The load for this mixed receptacle branch is supplied by
a line-to-line and line-to-neutral configuration
(line 1 to line 2 and line 1 to neutral).
line-2-line-3-and-line-2-neutral
The load for this mixed receptacle branch is supplied by
a line-to-line and line-to-neutral configuration
(line 2 to line 3 and line 2 to neutral).
line-3-line-1-and-line-3-neutral
The load for this mixed receptacle branch is supplied by
a line-to-line and line-to-neutral configuration
(line 3 to line 1 and line 3 to neutral).
unknown-line-neutral
The load for this branch is supplied by
a line-to-neutral configuration. The system is unable to
determine which lines are supporting the load.
unknown-line-line
The load for this branch is supplied by
a line-to-line configuration. The system is unable to
determine which lines are supporting the load.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
not-specified(0), line-1-neutral(1), line-2-neutral(2), line-3-neutral(3), line-1-line-2(4), line-2-line-3(5), line-3-line-1(6), line-1-line-2-and-line-1-neutral(7), line-2-line-3-and-line-2-neutral(8), line-3-line-1-and-line-3-neutral(9), unknown-line-neutral(10), unknown-line-line(11) |
|
lgpPduRbEntryRcpCount |
1.3.6.1.4.1.476.1.42.3.8.40.20.1.60 |
The number of receptacles on this receptacle branch. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduRbEntryEpRated |
1.3.6.1.4.1.476.1.42.3.8.40.20.1.70 |
Rated Line Voltage for the receptacle branch and its associated
receptacles (i.e. This is the nominal line voltage that is
available to the connected load; it is NOT a measured voltage.) |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduRbEntryEcRated |
1.3.6.1.4.1.476.1.42.3.8.40.20.1.75 |
This is the rated input line current for the module
(it is NOT the measured current). |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduRbEntryFreqRated |
1.3.6.1.4.1.476.1.42.3.8.40.20.1.80 |
This is the rated electrical frequency for the receptacle branch
and its associated receptacles |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduRbEntryEnergyAccum |
1.3.6.1.4.1.476.1.42.3.8.40.20.1.85 |
Total accumulated energy, measured at the receptacle branch input,
since the last energy reset. Writing a value of 0 (zero) to this
causes the accumulated energy to be reset. Writing a non-zero
value is invalid and shall result in a write error and the
total energy value remains unchanged.
If the energy has not been reset and has not wrapped, then this
is the total energy since installation.
This value persists across boot events.
NOTE: Resetting this value does not reset the values for the
individual receptacles. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduRbEntryEpLNTenths |
1.3.6.1.4.1.476.1.42.3.8.40.20.1.100 |
The line-to-neutral measurement of the Electrical Potential
measured in Volts RMS (Root Mean Squared). |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduRbEntryPwr |
1.3.6.1.4.1.476.1.42.3.8.40.20.1.115 |
The line-to-neutral measurement of the Real Power (Wattage) |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduRbEntryAp |
1.3.6.1.4.1.476.1.42.3.8.40.20.1.120 |
The line-to-neutral measurement of the Apparent Power (VA) |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduRbEntryPf |
1.3.6.1.4.1.476.1.42.3.8.40.20.1.125 |
The line-to-neutral measurement of the Power Factor of the
receptacle branches' input. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
lgpPduRbEntryEcHundredths |
1.3.6.1.4.1.476.1.42.3.8.40.20.1.130 |
The line-to-neutral measurement of the Electrical Current
measured in Amperes RMS (Root Mean Squared). |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduRbEntryEcThrshldUndrAlm |
1.3.6.1.4.1.476.1.42.3.8.40.20.1.135 |
The threshold at which an under current alarm is activated. If
the measured current (lgpPduRbEntryEc) is equal to or below
this percentage of the full scale rated value
(lgpPduRbEntryEcRated), an under current alarm
is activated |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduRbEntryEcThrshldOvrWarn |
1.3.6.1.4.1.476.1.42.3.8.40.20.1.140 |
The threshold at which an over current warning is activated. If
the measured current (lgpPduRbEntryEc) is equal to or over
this percentage of the full scale rated value
(lgpPduRbEntryEcRated), an over current warning
is activated |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduRbEntryEcThrshldOvrAlm |
1.3.6.1.4.1.476.1.42.3.8.40.20.1.145 |
The threshold at which an over current alarm is activated. If
the measured current (lgpPduRbEntryEcLN) is equal to or over
this percentage of the full scale rated value
(lgpPduRbEntryEcRated), an over current alarm
is activated |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduRbEntryEcAvailBeforeAlarmHundredths |
1.3.6.1.4.1.476.1.42.3.8.40.20.1.150 |
The amount that the current/amperage may increase from its present
value before an over current alarm occurs. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduRbEntryEcUsedBeforeAlarm |
1.3.6.1.4.1.476.1.42.3.8.40.20.1.160 |
The percent of current utilization relative to the over current
alarm threshold. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduRbEntryEpLLTenths |
1.3.6.1.4.1.476.1.42.3.8.40.20.1.170 |
The line-to-line measurement of the Electrical Potential
measured in Volts RMS (Root Mean Squared). |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduRbEntrySwOverCurrentProtection |
1.3.6.1.4.1.476.1.42.3.8.40.20.1.175 |
The configuration parameter to enable or disable the Branch
SW Over Current Protection feature.If the feature is enabled, in case of Over Current Warning or Alarm condition, following action will be taken on the receptacles:
Locked & On - No Change
Locked & Off - No Change
Unlocked & Off - Turn it Off and Lock it
Unlocked & On - If load present, No Change. If no load, turn it Off and Lock it.
No action will be taken if the feature is disabled.
Note: Only applicable to PDU models where receptacle measurement and control is possible. Not applicable to branch monoitoring models
disabled
This function is disabled.
enable
This function is enabled. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
disable(0), enable(1) |
|
lgpPduRbLineEntry |
1.3.6.1.4.1.476.1.42.3.8.40.40.1 |
This entry defines the attributes to be populated in the
various columns of the 'lgpPduRbLineTable'. The table is
indexed by three indexes. The 'lgpPduEntryIndex' references
a PDU in the 'lgpPduTable' to which this receptacle branch
line/phase measurement belongs. The 'lgpPduRbEntryIndex' together
with the 'lgpPduEntryIndex' references the receptacle branch
in the 'lgpPduRbTable'. The 'lgpPduRbLineEntryIndex' represents
the line/phase of the measurements in the row of this table.
Together these three indexes uniquely identify a phase/line
measurement on a receptacle branch within a PDU being monitored
by this agent.
|
Status: deprecated |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
LgpPduRbLineEntry |
|
|
lgpPduRbLineEntryIndex |
1.3.6.1.4.1.476.1.42.3.8.40.40.1.1 |
This is the index that indicates the row of the
'lgpPduRbLineTable' |
Status: deprecated |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduRbLineEntryId |
1.3.6.1.4.1.476.1.42.3.8.40.40.1.5 |
Runtime assigned branch identifier. |
Status: deprecated |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduRbLineEntryLine |
1.3.6.1.4.1.476.1.42.3.8.40.40.1.10 |
The line number or phase that the measurement for this
receptacle branch represents for each measurement in this row of
the table. The phases are as follows:
Line# Description
----- ---------------------------------------------------
1 Line 1-N (A) for Line-to-Neutral measurements
2 Line 2-N (B) for Line-to-Neutral measurements
3 Line 3-N (C) for Line-to-Neutral measurements
1 Line 1-2 (A-B) for Line-to-Line measurements
2 Line 2-3 (B-C) for Line-to-Line measurements
3 Line 3-1 (C-A) for Line-to-Line measurements
|
Status: deprecated |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
phase1(1), phase2(2), phase3(3) |
|
lgpPduRbLineEntryEpLNTenths |
1.3.6.1.4.1.476.1.42.3.8.40.40.1.19 |
The line-to-neutral measurement of the Electrical Potential
measured in Volts RMS (Root Mean Squared). |
Status: deprecated |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduRbLineEntryEpLN |
1.3.6.1.4.1.476.1.42.3.8.40.40.1.20 |
The line-to-neutral measurement of the Electrical Potential
measured in Volts RMS (Root Mean Squared). |
Status: deprecated |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduRbLineEntryEc |
1.3.6.1.4.1.476.1.42.3.8.40.40.1.21 |
The line-to-neutral measurement of the Electrical Current
measured in Amperes RMS (Root Mean Squared). |
Status: deprecated |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduRbLineEntryPwr |
1.3.6.1.4.1.476.1.42.3.8.40.40.1.22 |
The line-to-neutral measurement of the Real Power (Wattage) |
Status: deprecated |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduRbLineEntryAp |
1.3.6.1.4.1.476.1.42.3.8.40.40.1.23 |
The line-to-neutral measurement of the Apparent Power (VA) |
Status: deprecated |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduRbLineEntryPf |
1.3.6.1.4.1.476.1.42.3.8.40.40.1.24 |
The line-to-neutral measurement of the Power Factor of the
receptacle branches' input. |
Status: deprecated |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
lgpPduRbLineEntryEcHundredths |
1.3.6.1.4.1.476.1.42.3.8.40.40.1.25 |
The line-to-neutral measurement of the Electrical Current
measured in Amperes RMS (Root Mean Squared). |
Status: deprecated |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduRbLineEntryEcThrshldUndrAlm |
1.3.6.1.4.1.476.1.42.3.8.40.40.1.35 |
The threshold at which an under current alarm is activated. If
the measured current (lgpPduRbLineEntryEc) is equal to or below
this percentage of the full scale rated value
(lgpPduRbEntryEcRated), an under current alarm
is activated |
Status: deprecated |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduRbLineEntryEcThrshldOvrWarn |
1.3.6.1.4.1.476.1.42.3.8.40.40.1.36 |
The threshold at which an over current warning is activated. If
the measured current (lgpPduRbLineEntryEc) is equal to or over
this percentage of the full scale rated value
(lgpPduRbEntryEcRated), an over current warning
is activated |
Status: deprecated |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduRbLineEntryEcThrshldOvrAlm |
1.3.6.1.4.1.476.1.42.3.8.40.40.1.37 |
The threshold at which an over current alarm is activated. If
the measured current (lgpPduRbLineEntryEcLN) is equal to or over
this percentage of the full scale rated value
(lgpPduRbEntryEcRated), an over current alarm
is activated |
Status: deprecated |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduRbLineEntryEcAvailBeforeAlarmHundredths |
1.3.6.1.4.1.476.1.42.3.8.40.40.1.39 |
The amount that the current/amperage may increase from its present
value before an over current alarm occurs. |
Status: deprecated |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduRbLineEntryEcAvailBeforeAlarm |
1.3.6.1.4.1.476.1.42.3.8.40.40.1.40 |
The amount that the current/amperage may increase from its present
value before an over current alarm occurs. |
Status: deprecated |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduRbLineEntryEcUsedBeforeAlarm |
1.3.6.1.4.1.476.1.42.3.8.40.40.1.41 |
The percent of current utilization relative to the over current
alarm threshold. |
Status: deprecated |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduRbLineEntryEpLL |
1.3.6.1.4.1.476.1.42.3.8.40.40.1.60 |
The line-to-line measurement of the Electrical Potential
measured in Volts RMS (Root Mean Squared). |
Status: deprecated |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduRbLineEntryEpLLTenths |
1.3.6.1.4.1.476.1.42.3.8.40.40.1.61 |
The line-to-line measurement of the Electrical Potential
measured in Volts RMS (Root Mean Squared). |
Status: deprecated |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduRcpEntry |
1.3.6.1.4.1.476.1.42.3.8.50.20.1 |
This entry defines the attributes to be populated in the
various columns of the 'lgpPduRcpTable'. This table is indexed
by three indexes. The 'lgpPduEntryIndex' references a PDU in
the 'lgpPduTable' that a given row in this table represents.
The 'lgpPduRbEntryIndex' together with the 'lgpPduEntryIndex'
specifies a row in the 'lgpPduRbTable' that the receptacle
belongs. The 'lgpPduRcpEntryIndex' identifies the particular
receptacle within the branch.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
LgpPduRcpEntry |
|
|
lgpPduRcpEntryIndex |
1.3.6.1.4.1.476.1.42.3.8.50.20.1.1 |
This is the index that indicates the receptacle position on the
receptacle branch. This along with the other two indexes on the
lgpPduRcpTable uniquely identify the receptacle in this table. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduRcpEntryId |
1.3.6.1.4.1.476.1.42.3.8.50.20.1.5 |
A runtime assigned receptacle identification number. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduRcpEntryUsrLabel |
1.3.6.1.4.1.476.1.42.3.8.50.20.1.10 |
User assigned label for this receptacle. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
lgpPduRcpEntryUsrTag1 |
1.3.6.1.4.1.476.1.42.3.8.50.20.1.15 |
User assigned Tag to assist in identifying or grouping this
receptacle within the end-users domain. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
lgpPduRcpEntryUsrTag2 |
1.3.6.1.4.1.476.1.42.3.8.50.20.1.20 |
User assigned Tag to assist in identifying or grouping this
receptacle within the end-users domain. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
lgpPduRcpEntrySysAssignLabel |
1.3.6.1.4.1.476.1.42.3.8.50.20.1.25 |
System assigned identifier representing the receptacle. The value
is independent of any user assigned label or tag. The exact format
of this label is system dependent and is subject to change,
therefore, it should not be referenced for programmatic use. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
lgpPduRcpEntryPosition |
1.3.6.1.4.1.476.1.42.3.8.50.20.1.30 |
A number representing the position of the receptacle within the
receptacle branch. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduRcpEntryType |
1.3.6.1.4.1.476.1.42.3.8.50.20.1.40 |
The type or form of receptacle. The enumerations are specified
in well-known industry standard terms and abbreviations. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
not-specified(0), nema-5-20R-20-Amp(1), iec-C13-sheet-F-10-Amp(2), iec-C19-sheet-J-16-Amp(3), cee-7-type-E-schuko(7) |
|
lgpPduRcpEntryLineSource |
1.3.6.1.4.1.476.1.42.3.8.50.20.1.45 |
This represents the line source that is supplying power to this
receptacle.
not-specified
The line source supplying power to the load for this
receptacle has not been specified/configured.
line-1-N
The load for this receptacle is supplied by
a line-to-neutral configuration. (line 1 to neutral).
line-2-N
The load for this receptacle is supplied by
a line-to-neutral configuration. (line 2 to neutral).
line-3-N
The load for this receptacle is supplied by
a line-to-neutral configuration. (line 3 to neutral).
line-1-line-2
The load for this receptacle is supplied by
a line-to-line configuration (line 1 to line 2).
line-2-line-3
The load for this receptacle is supplied by
a line-to-line configuration (line 2 to line 3).
line-3-line-1
The load for this receptacle is supplied by
a line-to-line configuration (line 3 to line 1).
unknown-line-neutral
The load for this receptacle is supplied by
a line-to-neutral configuration. The system is unable to
determine which lines are supporting the load.
unknown-line-line
The load for this receptacle is supplied by
a line-to-line configuration. The system is unable to
determine which lines are supporting the load.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
not-specified(0), line-1-N(1), line-2-N(2), line-3-N(3), line-1-line-2(4), line-2-line-3(5), line-3-line-1(6), unknown-line-neutral(7), unknown-line-line(8) |
|
lgpPduRcpEntryCapabilities |
1.3.6.1.4.1.476.1.42.3.8.50.20.1.50 |
Receptacle capabilities describes what an individual receptacle is
capable of.
no-optional-capabilities
The receptacle is unable to report measurements and lacks
control capabilities.
measurement-only
The receptacle is capable of reporting multiple measurements.
measurement-and-control
The receptacle is capable of reporting multiple measurements
and controlling the state.
control-only
The receptacle is capable of controlling the state.
current-measurement-only
The receptacle is capable of reporting the current/amperage
only.
current-measurement-and-control
The receptacle is capable of reporting the current/amperage and
has the ability to control the state. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
not-specified(0), no-optional-capabilities(1), measurement-only(2), measurement-and-control(3), control-only(4), current-measurement-only(5), current-measurement-and-control(6) |
|
lgpPduRcpEntryEp |
1.3.6.1.4.1.476.1.42.3.8.50.20.1.55 |
Voltage being delivered to the load attached to the receptacle.
Alternating Current RMS Electrical Potential measurement. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduRcpEntryEpTenths |
1.3.6.1.4.1.476.1.42.3.8.50.20.1.56 |
Voltage being delivered to the load attached to the receptacle.
Alternating Current RMS Electrical Potential measurement. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduRcpEntryEc |
1.3.6.1.4.1.476.1.42.3.8.50.20.1.60 |
Current (amperage) being delivered to the load attached to
the receptacle. Electrical Current is measured in
Amperes RMS (Root Mean Squared). |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduRcpEntryEcHundredths |
1.3.6.1.4.1.476.1.42.3.8.50.20.1.61 |
Current (amperage) being delivered to the load attached to
the receptacle. Electrical Current is measured in
Amperes RMS (Root Mean Squared). |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduRcpEntryPwrOut |
1.3.6.1.4.1.476.1.42.3.8.50.20.1.65 |
Real Power (watts) being delivered to the load attached to
the receptacle. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduRcpEntryApOut |
1.3.6.1.4.1.476.1.42.3.8.50.20.1.70 |
Apparent Power (volt-amps) being delivered to the load
attached to the receptacle. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduRcpEntryPf |
1.3.6.1.4.1.476.1.42.3.8.50.20.1.75 |
Receptacle Power Factor, which is the ratio of real power
to apparent power (i.e. ratio of watts to volts-amps). |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduRcpEntryFreq |
1.3.6.1.4.1.476.1.42.3.8.50.20.1.80 |
The measured line frequency being delivered to the load
attached to the receptacle. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduRcpEntryEnergyAccum |
1.3.6.1.4.1.476.1.42.3.8.50.20.1.85 |
Total accumulated energy, measured at the module input, since
the last energy reset. Writing a value of 0 (zero) to this
causes the accumulated energy to be reset. Writing a non-zero
value is invalid and shall result in a write error and the
total energy value remains unchanged.
If the energy has not been reset and has not wrapped,
then this is the total energy since installation.
This value persists across boot events. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduRcpEntryPwrOnDelay |
1.3.6.1.4.1.476.1.42.3.8.50.20.1.90 |
The amount of time to wait before power is applied to the
receptacle after a power strip is turned on or rebooted.
This can be used to stagger the powering of multiple
receptacles in order to prevent a large initial current
draw. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduRcpEntryPwrState |
1.3.6.1.4.1.476.1.42.3.8.50.20.1.95 |
unknown
The current power state is unknown.
off
The current power state of the receptacle is OFF.
on
The current power state of the receptacle is ON.
off-pending-on-delay
The current power state of the receptacle is OFF. The power
will be ON at the expiration of the ON delay of this
receptacle. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
unknown(0), off(1), on(2), off-pending-on-delay(3) |
|
lgpPduRcpEntryPwrUpState |
1.3.6.1.4.1.476.1.42.3.8.50.20.1.96 |
The 'Power Up State' defines the state to which the receptacle shall return
after a power cycle of the PDU.
on
The receptacle shall be switched to the ON state after the power on delay
timer (lgpPduRcpEntryPwrOnDelay).
off
The receptacle shall be in the OFF state upon power cycle.
last-state
The receptacle shall be put to the previous state. Again, on state will be
effective only after the power on delay (lgpPduRcpEntryPwrOnDelay). |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
on(1), off(2), last-state(3) |
|
lgpPduRcpEntryControl |
1.3.6.1.4.1.476.1.42.3.8.50.20.1.100 |
This object represents the current and persistent (configured)
power state of the receptacle. The receptacle can also be
controlled by writing to this object.
off
The current and persisted (configured) power state of the
receptacle is 'off'. When writing 'off' to this object the
receptacle, if ON, will be turned OFF and its persistent
(configured) power state will be set to 'off'.
on
The current and persisted (configured) power state of the
receptacle is 'on'. When writing 'on' to this object the
receptacle, if 'off', will be turned 'on' and its persistent
(configured) power state will be set to 'on'.
cycle-power
The receptacle is currently in a power-cycle state. The
power to the receptacle is being turned off momentarily and
will then revert to being 'on'.
When writing 'cycle-power' to this OBJECT if the receptacle is
'on' it will be momentarily turned 'off' and then revert to the
'on' state. The receptacle's persistent (configured) power
state will be left unchanged ('on').
If the receptacle is OFF writing cycle-power has no
affect on the receptacle.
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
off(0), on(1), cycle-power(2) |
|
lgpPduRcpEntryControlLock |
1.3.6.1.4.1.476.1.42.3.8.50.20.1.105 |
This object represents the locked state of the receptacle.
unknown
The lock state of the receptacle is not known at this time.
locked
If the receptacle is 'locked' then its current persisted
(configured) state can not be changed.
unlocked
If the receptacle is 'unlocked', then a user with proper
permissions may change the receptacles state. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
unknown(0), unlocked(1), locked(2) |
|
lgpPduRcpEntryEcThrshldUnderAlarm |
1.3.6.1.4.1.476.1.42.3.8.50.20.1.150 |
The threshold at which an under current alarm is activated. If
the measured current (lgpPduRbLineEntryEcLL) is equal to or below
this percentage of the full scale rated value
(lgpPduRbEntryEcRated), an under current alarm
is activated |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduRcpEntryEcThrshldOverWarn |
1.3.6.1.4.1.476.1.42.3.8.50.20.1.151 |
The threshold at which an over current warning is activated. If
the measured current (lgpPduRbLineEntryEcLL) is equal to or over
this percentage of the full scale rated value
(lgpPduRbEntryEcRated), an over current warning
is activated |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduRcpEntryEcThrshldOverAlarm |
1.3.6.1.4.1.476.1.42.3.8.50.20.1.152 |
The threshold at which an over current alarm is activated. If
the measured current (lgpPduRbLineEntryEcLL) is equal to or over
this percentage of the full scale rated value
(lgpPduRbEntryEcRated), an over current alarm
is activated |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduRcpEntryEcAvailBeforeAlarmHundredths |
1.3.6.1.4.1.476.1.42.3.8.50.20.1.159 |
The amount that the current/amperage may increase from its present
value before an over current alarm occurs. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduRcpEntryEcAvailBeforeAlarm |
1.3.6.1.4.1.476.1.42.3.8.50.20.1.160 |
The amount that the current/amperage may increase from its present
value before an over current alarm occurs. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduRcpEntryEcUsedBeforeAlarm |
1.3.6.1.4.1.476.1.42.3.8.50.20.1.161 |
The percent of current utilization relative to the over current
alarm threshold. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduRcpEntryEcCrestFactor |
1.3.6.1.4.1.476.1.42.3.8.50.20.1.162 |
Receptacle current crest factor, which is the peak amplitude of the
current waveform divided by the RMS value of the waveform. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduRcpEntryBlinkLED |
1.3.6.1.4.1.476.1.42.3.8.50.20.1.200 |
Blink the receptacle LED. Writing blinkLED(2) will cause the LED
to blink for a predefined duration of time. Reading this object
will always return noAction(1). |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
noAction(1), blinkLED(2) |
|
lgpPduRcpEntrySwOverTemperatureProtection |
1.3.6.1.4.1.476.1.42.3.8.50.20.1.205 |
The configuration parameter to enable or disable the Receptacle
SW Over Temperature Protection feature
If the feature is enabled, in case of Over Temperature Alarm condition,
following action will be taken on the receptacles:
Locked & Off - No Change
Unlocked & Off - No Change
Unlocked & On - Turn it Off.
Locked & On - Turn it Off and keep it Locked.
No action will be taken if the feature is disabled. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
disable(0), enable(1) |
|
lgpPduRcpEntryOperationCondition |
1.3.6.1.4.1.476.1.42.3.8.50.20.1.210 |
Receptacle Operating Condition - indicates the condition of the receptacle.
The operating condition has the following:
Normal
Normal operation without any alarm or warning.
Alarm
An Alarm condition due to over/under current.
Warning
A Warning condition due to over/under current
Abnormal
A condition in which the outlet is in 'Power Off State' but still drawing current. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
normalOperation(1), normalWithWarning(2), normalWithAlarm(3), abnormal(4) |
|
lgpPduRcpEntryCriticality |
1.3.6.1.4.1.476.1.42.3.8.50.20.1.215 |
The configuration parameter can be used by the user to mark a receptacle as
critical or non-critical. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
critical(0), notCritical(1) |
|
lgpPduRcpEntryPostOnDelay |
1.3.6.1.4.1.476.1.42.3.8.50.20.1.220 |
The 'Post On Delay' is the time interval (in seconds) that the PDU waits after
a command is issued to switch ON a receptacle before applying power to the receptacle
A value of zero implies that there is no delay (i.e. the receptacle is turned on
immediately on command issue). |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduRcpEntryPostOffDelay |
1.3.6.1.4.1.476.1.42.3.8.50.20.1.225 |
The 'Post Off Delay' is the time interval (in seconds) that the PDU waits after
a command is issued to switch OFF a receptacle before removing power from the receptacle
A value of zero implies that there is no delay (i.e. the receptacle is turned off
immediately on command issue). |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
lgpPduRcpEntryAddReceptacleToGroup |
1.3.6.1.4.1.476.1.42.3.8.50.20.1.230 |
This receptacle can be added to a group by writing a corresponding
OID to this column. The OID must be a pointer to the
lgpPduRcpGroupUsrLabel from the lgpPduRcpGroupTable.
For example, to add this receptacle to group 1, the oid
.1.3.6.1.4.1.476.1.42.3.8.50.30.10.1.1 would be written to
this column. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
OBJECT IDENTIFIER |
|
|
lgpPduRcpEntryRemoveReceptacleFromGroup |
1.3.6.1.4.1.476.1.42.3.8.50.20.1.235 |
This receptacle can be removed from a group by writing a corresponding
OID to this column. The OID must be a pointer to the
lgpPduRcpGroupUsrLabel from the lgpPduRcpGroupTable.
For example, to remove this receptacle from group 1, the oid
.1.3.6.1.4.1.476.1.42.3.8.50.30.10.1.1 would be written to
this column. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
OBJECT IDENTIFIER |
|
|
lgpPduRcpGroupEntry |
1.3.6.1.4.1.476.1.42.3.8.50.30.10.1 |
This entry defines the attributes to be populated in the
various columns of the 'lgpPduRcpGroupTable'.
This table is indexed by lgpPduRcpGroupIndex.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
LgpPduRcpGroupEntry |
|
|
lgpPduRcpGroupDisplayEntry |
1.3.6.1.4.1.476.1.42.3.8.50.30.20.1 |
This entry defines the attributes to be populated in the
various columns of the 'lgpPduRcpGroupDisplayTable'.
This table is indexed by two indexes.
The 'lgpPduRcpGroupIndex' references a receptacle group in
the 'lgpPduRcpGroupTable' that a given row in this table represents.
The 'lgpPduEntryIndex' references a PDU in the 'lgpPduTable'
that identifies the particular PDU receptacle list
within the receptacle group.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
LgpPduRcpGroupDisplayEntry |
|
|
lgpPduAuxSensorEntry |
1.3.6.1.4.1.476.1.42.3.8.60.10.1 |
This entry defines the attributes to be populated in the
various columns of the 'lgpPduAuxSensorTable'.
This table is indexed by both the 'lgpPduEntryIndex' which is
the sole index into the 'lgpPduTable' and the
'lgpPduAuxSensorIndex'which is a unique identifier for the
auxiliary sensor attached to the given PDU. Taken together these
two indexes uniquely identify an Auxiliary Sensor within this
agent. |
Status: deprecated |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
LgpPduAuxSensorEntry |
|
|
lgpPduAuxMeasEntry |
1.3.6.1.4.1.476.1.42.3.8.60.15.1 |
This entry defines the attributes to be populated in the
various columns of the 'lgpPduAuxMeasTable'.
This table is indexed by 'lgpPduEntryIndex' which is
the sole index into the 'lgpPduTable', 'lgpPduAuxSensorIndex' which
is a unique identifier for the auxiliary sensor attached to the
given PDU, and 'lgpPduAuxMeasSensorMeasurementIndex' which is the
measurement's index identified on the sensor. Taken together these
three indexes uniquely identify an Auxiliary Sensor Measurement
within this agent. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
LgpPduAuxMeasEntry |
|
|
lgpPduAuxMeasOrderEntry |
1.3.6.1.4.1.476.1.42.3.8.60.20.1 |
This entry defines the attributes to be populated in the
various columns of the 'lgpPduAuxMeasOrderTable'.
This table is indexed by 'lgpPduEntryIndex' which is
the sole index into the 'lgpPduTable' and 'lgpPduAuxMeasSensorIndex'
which is a unique identifier for the auxiliary sensor attached to the
given PDU. Taken together these two indexes uniquely
identify a Auxiliary Sensor within this agent. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
LgpPduAuxMeasOrderEntry |
|
|